A&D UC-321 User's Manual

A&D UC-321 User's Manual
 MIND) Instruction Manual
Before Use
Precautions .........— wee... 1
Scale Components ........... e. 2
Display Symbols... creer ©
Precision Health Scale Installing for Replacing) Batteries .. 3
Model UC-321 Operations
Normal Measurement. ............... —
(£5777 ) Memory Function... €
Target FUNnction ........ emma. B
BM] indication.... TO
References |
SpDecificatiONS are . 12
Maintaining the Scale ............ 12
Before Reguesting Service ........ .. 12
Precautions
I} Please read this booklet before using your scale.
i Do not place your scale on a soff, wet or slippy floor.
R ls recommended you place your scale on the solid and level ficor.
Lt Your scale contains delicate, high-precision parts. Avoid extremes in
temperature, humidity, direct sunlight, shock, moisture and dust.
[J Do not step on your scale with your feet wet so as to prevent you from = TT
slipping and falling down. It is recommended that vou sies on the cen- CUT Shock ——4
ter portion of your scale gently.
Do not step on the display window.
Do not open the case of the scale.
If you press and hold the measurement switch, the battery power is
consumed.
Co
Indications for Use 7
Li The UC-321 was designed for adult use at home.
Compliance with European Directive
C € The scale complies with the statutory EMC (Electromagnetic Compatibility) directive 89/
336/EEC, Note: The displayed value may be
adversely affected under extreme electromagnetic influences.
ML 41000285
Scale Components
Display Function Indicator | Back
OK Mark
sf EIGHT
| a BMI
о — MEMORY
(ame | 8 GE
Low Battery Mark | Slide Switch
Front
A
Measurement Switch Battery Compartment
G The following four measurements can be selected by the function switch.
Refer to "Normal Measurement” and "Measuring a baby or an animal”.
WEIGHT | The function to measure your weight, the weight of a baby or
_ animal.
BMI Refer to "BMI Indication”.
The BMI is a helpful indicator of body weight condition, in adults,
| Refer to “Memory Function”.
MEMORY | Up to 31 weight data can be stored in memory.
The difference from the previous result is displayed automatically.
Refer to “Target Function”.
TARGET | The difference between the preset target weight and the current
weight can be displayed. |
Q The scale has the “automatic-power-off function to turn the scale off after no
operation for ten seconds. Therefore, the scale has no off switch.
190
Display Symbols
e This symbol is displayed, when measurement display is stable.
Low battery mark. If this mark is displayed, replace the batteries with
new ones.
-4, » | Function indication. The current function is indicated.
Installing (or Replacing) Batteries
Caution
U
u
Insert each battery with its positive (+) and negative (-) terminals properly
aligned with the corresponding marks on the scale. If you fail these battery
directions, it may cause battery leakage.
Replace all four batteries with new ones, when a mark is displayed.
Do not mix used and new batteries. It may cause damage to the battery or
scale, if used.
When batteries are completely drained, 4 mark is not displayed.
The battery life is dependant upon the environmental temperature, battery
performance and usage.
Remove the batteries from the battery compartment, when the scale is not to
be used for a long time. They may leak and damage your scale.
The battery life of accessory batteries may be shorter than new ones.
Steps for Installing (or Replacing) Batteries
1 Remove the battery compartment cover on the ey
underside of the scale by gently pushing on A
LU a
2 Place four new batteries with the positive (+)
3 Replace the cover by sliding it into the com-
the arrow and lifting the cover backward.
and negative (-) terminals properly aligned with
the corresponding marks on the scale.
partment and gently pressing into place.
Normal Measurement
Measuring Your Weight
1 Set the slide switch to “WEIGHT”. Slide switch
Weight
+
Measurement switch
2 Press the measurement switch gently. or “HC Г a:
All display segments are indicated for several + ИСИ СН Ka
seconds, then displaying 0.00 kg and the O mark..
OK mark
3 Step on your scale. О Г m [| >IWEIGHT
Step on your scale gently. When the O mark MS к
disappears, the measurement is started. Remain ПЕ y
still during measurement. w
Ifthe condition to display 0.00 kg is maintained Step on the scale
for approximately ten seconds, the scale is au- a
tomatically turned off. |
4 Your weight can be read after the O CU [> WEIGHT
mark is displayed. ЕН к
The scale is turned off automatically after ap- —= J
proximately five seconds.
5 Step off the scale. Step off the scale
WEIGHT
BMI
MEMORY-
TARGET
~~ но
Slide switch Measurement switch
Measuring a Baby or an Animal
1 Set the slide switch to “WEIGHT”.
2 Press the measurement switch gently
and step on your scale.
All display segments are indicated for several sec-
onds. Step on the scale without any baby or ani-
mal in your hands before displaying 0.00 kg.
Pick up the baby or animal and step
on the scale again.
Step on your scale with the baby and animal
within ten seconds after displaying 0.00 kg and
the Q mark. Remain still during measurement
until displaying © mark.
4 The weight of the baby or animal can
be read after displaying the O mark.
The scale 1s turned off automatically after
approximately five seconds.
5 Step off the scale.
Slide switch
Weight
—
Measurement switch
Step on the scale
ICICI:
ENCINA
Ok mark
|
о FA WEIGHT
+
Take the baby or the animal
and step on the scale
|
о [WEIGHT |
Step off the scale
The Memory Function
Up to 31 weight data can be stored in memory. The 32nd data is stored by
deleting the oldest stored data. The difference from the previous result is
displayed automatically,
Storing a Current Weight.
1 Set the slide switch to “MEMORY”.
2 Press the measurement switch gently.
The last weight is displayed.
3 Step on your scale.
Step on your scale gently, after displaying
0.00 kg and the O mark. When the O mark
disappears, the measurementis started, Re-
main still during measurement,
If the condition to display 0.00 kg 1s main-
tained for approximately ten seconds, the
scale is automatically turned off.
4 The weight can be read after the ©
mark is displayed.
5 Step off the scale.
6 The weightis stored in memory
and the difference from the last
weight is displayed.
The weight data is stored in memory
and the difference from the previous
result is displayed for approximately
five seconds. And, the scale is auto-
matically turned off.
Slide switch
Memory
Measurement switch
Last weight
Clic,
OUI
dma
q mark
о
|
Y
д
I
"E—
€
=
Step on the scale
|
|
|
с
|
——
E
"E.
a
‘y
Cl
|
||
В
Gain
‘qu
=
ci
D
Step off the s
pa
|
; сны”
Y
I
|_|
Pr
Ea
Of
=
The same
weight
Ns
||
A
Y
TE анна
"E.
Loss
all
9
A
||
Y
PD
т
ama -
—
MEMORY
Kg
MEMORY
Kg
MEMORY
kg
MEMORY
kg
Displaying Weight Data Stored in the Scale
The stored measurement data is displayed in order beginnings with the
most recent measurement.
1 Set the slide switch to “MEMORY”. Slide switch
Memory
2 Press and hold the measurement switch Press and hold
gently in the condition of turning off the measurement switch
scale.
Weight data are displayed in order from the last
result. The scale 1s automatically turned off.
It you want to stop the display, press the mea-
surement switch,
_ I Lemon
From last result in order +
MEMORY
ILL}
Slide switch Measurement switch
The Target Function
The difference between the preset target weight and the current weight can
he displayed.
Presetting a New Target Weight
1 Set the slide switch to “TARGET”, Slide switch
Target
2 Press and hold the measurement switch Press and hold
gently in the condition of displaying measurement switch
nothing. Е
The last preset target weight is displayed.
Press and hold
3 Press the measurement switch gently to Press and release
display a new target weight. measurement switch
Press and hold the measurement switch to in-
crease the display, until the desired value 18 In-
dicated to specify a new target weight.
Г! TARGET
i
LIL
q ES bu
4 Release the measurement switch to
store the new target weight, when Release
measurement switch
displaying It.
The scale is automatically turned off after dis-
playing a new target weight for approximately
five seconds.
WEIGHT
EMI
MEMORY-
TARGET
Slide switch Measurement switch
Comparing a Current Weight with a Preset Target Weight
1 Set the slide switch to “TARGET”
2 Press the measurement switch gently.
The stored target weight is displayed.
3 Step on the scale. |
Step on your scale gently after displaying
0.00 kg and the O mark. When the O mark
disappears, the measurement is started.
Remain still during measurement.
If the condition to display 0.00 kg is main-
tained for approximately ten seconds, the
scale is automatically turned off.
The difference between the pre-
set target weight and the current
weight is displayed.
The scale is automatically turned off
after the difference has been displayed
for approximately five seconds.
5 Step off the scale.
Target weight
Measuring is
In process
Gain
The same
weight
Loss
Slide switch
Target
Measurement switch
rn.
NINN
Фен!
OK mark
O
J
=,
Y
Чили
|=
LI
|
нь.
|
Чи.
= €
Step on the scale
€
|
|
€ | €
|
+
a
|
Ll
Y
[
D
=
1
an
Y
o
{
Ld
i
"E
I+
|
2
|
Y
e
L
E
|
—— ¡a
J
{
| y,
«еп
Step off the scale
TARGET
Kg
TARGET
Kg
TARGET
kg
BMI Indication
BMI
Body Mass Index or BMI (kg/m?), based
on an individualis height and weight, is | Underweight Below 18.5
a helpful indicator of underweight, over- — | Normal || 18.510 24.9
weight or obesity, in adults. Overweight | 25.0 to 29.9
According to the new NHLBI (National Obesity 30.0 and Above
Institutes of Health) guidelines, the BMI - |
score means the following list. BMI = Weight (kg)
| Height (m) x Height (m)
Presetting Your Height
store your height before measuring your weight to calculate the BMI.
The scale can store a height between 30 cm and 220 cm in increments of
0.1 cm. |
1 Set the slide switch to “BMI”. Slide switch
BMI
2 Press and hold the measurement switch gently Press and hold
in the condition of displaying nothing. measurement switch
The preset height is displayed.
Gu
3 Press the measurement switch gently to dis- Press and hold
i or
play a new height. Press and release —.
Press and hold the measurement switch to increase the measurement switch
display, until the indicated value is correct, to specify
anew target weight.
!
d
BMI |
lL il
ee
4 Release the measurement switch to store a
new height, when displaying it. Release —
The scale is automatically turned off after displaying measurement switch
the new height for approximately five seconds.
- 10 -
Displaying the BMI Score
1 Set the slide switch to “BMI”. Slide switch
BMI
2 Press the measurement switch gently. — Measurement switch
The preset height is displayed. Preset height BIT
3 Step on the scale. о 3 >
Step on your scale gently after displaying 0.00 anil = ПН ИЦ | kg
kg and the O mark. When the O mark disap- Ша =
pears, the measurement is started. Remain still +
during measurement. Step on the scale
If the condition to display 0.00 kg is maintained
tor approximately ten seconds, the scale is au-
tomatically turned off.
4 The preset height and calculated BMI aa
score is displayed alternately. Weight 1 (CU | к
The scale is automatically turned off after dis- — + — 9
playing them for approximately ten seconds. For approximately =
ten seconds =
У
BMI score _ TH
вм L MI
5 Step off the scale. Step + scale
WEIGHT | EZ]
В —
MEMORY
TARGET |
Slide switch Measurement switch
- 17 - | a
Specifications
Digital display Liquid crystal display, 25 mm character height
Maximum capacity 150 kg
Minimum display 0.05 kg
Power source Four type AA batteries (REF, 1.5 volt x 4)
Battery life Approximately 2000 measurements
Accessories Instruction manual
Specifications are subject to change without prior notice and any obligation
on the part of the manufacturer.
Maintaining the Scale
0 Clean the scale with a dry, soft cloth or a cloth moistened with water and a
mild detergent. Never use alcohol, benzene, thinner or other harsh chemi-
cals to clean the scale.
J Remove the batteries, if the scale is not going to be used for a long time,
Before Requesting Service
—— irivivk
If this happens Please do this |
Nothing is displayed by pressing the | Check the battery installation.
measurement switch. Replace with four new batteries.
The indication is fixed to 85556. Remove and reinstall the batteries.
H or Lis displayed. |
The difference between an estimated | Move your scale to a flat, solid surface.
weight and a measured weight is bigger.| Does the under case touch to the floor?
E-B is displayed. | Replace batteries and try again.
If you can not locate and fix the problem, contact your supplier, or the A&D
service group. The A&D service group will support authorized suppliers
about technical information, spare parts and units.
A&D Co.,LTD.
1-243 Asahi, Kitamoto-shi, Saitama, 364-8585 JAPAN
Telephone: [81] (485) 93-1111 Fax: [81] (485) 93-1119
A&D INSTRUMENTS LTD.
<Authorized Representative Established in the European Community>
Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxon OX14 1DY United Kingdom
Telephone: [44] (1235) 550420 Fax [44] (1235) 550485
Measuring weight on shag carpet
June 2001
Please use the enclosed add-on feet if your wish to use the Precision
Personal Scale on shag carpet.
How to insert the add-on feet
There are two pins on each add-on foot side. Match those pins to the
holes on the scale leg and insert firmly. Make sure to put add-ons to all
4 legs.
Notes
1. Please be careful not to fall when using the add-on feet.
2. We recommend using this scale on steady and level ground.
WM:PD40003686
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement