Accusplit 980-312 Operating instructions


Add to my manuals
4 Pages

advertisement

Accusplit 980-312 Operating instructions | Manualzz

b-1

ACCUSPLIT, Inc.

6120 Stoneridge Mall Rd., Suite 210

Pleasanton, CA 94588 USA

800-965-2008 • 925-226-0888 • FAX 925-463-0147 www.ACCUSPLIT.com • [email protected]

980-312

ACCUSPLIT®

E X C L U S I V E

AX602FY

STOPWATCH

OPERATING

INSTRUCTIONS

2-3

ACCUSPLIT® AX602FY

DIGITAL 100 MEMORY STOPWATCH

WITH SPLIT AND LAP TIME MEASUREMENT AND

STROKE/FREQUENCY MEASURING FUNCTIONS

FEATURES

The Quartz Stopwatch is a digital stopwatch featuring memory and stroke/frequency measuring functions. In addition, the stopwatch is water resistant. Therefore, it is suitable for aquatic sports or use in rainy weather.

• STOPWATCH

The stopwatch can measure up

to 10 hours in 1/100 seconds.

• SPLIT TIME/LAP TIME

MEASUREMENT

Up to 100 split times and lap

times can be measured.

2

• LARGE-SIZED THREE-ROW DISPLAY PANEL

Total elapsed time, split time and lap time are displayed at the same

time in separate rows, and they can be measured successively

without releasing split or lap time measurement.

• MEMORY FUNCTION

Up to 100 measurements can be stored in memory, and they can be

recalled after the measurement is over.

• TIME/CALENDAR DISPLAY

Year, month, date, hour, minutes, and seconds can be displayed while

the stopwatch is not in use.

• BATTERY LIFE INDICATOR

Lithium battery CR2032 or equivalent is used.

• ACCUSPLIT “X” CASE

Exclusive professional case with no-fail buttons.

3

4

4-5

There are four buttons as indicated in the illustration.

TIME/CALENDAR display

B

C

STOPWATCH display

A

D

STROKE/FREQUENCY

MEASURING display

STROKE/FREQUENCY MEASURING MODE

TIME/CALENDAR SETTING

ACCUSPLIT products use a common setting procedure known as S1-S2-S3-S4.

S1 (2 sec) - Enter set function OR

S1 (4 sec) - Enter set function & clear the current settings

S2 – Select fi eld to be set

(selected fi eld will fl ash)

S3 – Set fi eld to desired settings

S4 – Exit setting function

Hour

B

C

A

Year

Month and date

Seconds

Minutes

D

TIME/CALENDAR display mark

1. Press “D” to show the time/calendar display. The time/calendar display

mark will appear.

2. S1 – Press and hold “B” for 2 seconds until seconds display begins fl ashing.

5

6-7

3. S2 – Press “B” repeatedly to select the digits (fl ashing) to be adjusted.

With each press of “B,” the digits to be adjusted change over in the

following order.

seconds minutes hour year month

Note: The watch exits set mode automatically after setting date.

date

4. S3 – Press “A” to set the fl ashing digits or reset the seconds to “00”.

• The digits move quickly if “A” is kept pressed.

• When the seconds digits count any number from ”30” to “59” and “A” is

pressed, one minute is added and the second digits are reset to “00”.

5. S4 – After all the adjustments are completed, press “A” repeatedly until watch

exits set mode and returns to the TIME/CALENDAR display.

Notes:

1. Hour digits are displayed in the 24-hour indication.

2. Year digits can be set from 1988 to 2027. The calendar adjusts automatically for odd and even months including February of leap years.

6

STOPWATCH

Press “D” in the TIME/CALENDAR display to show the STOPWATCH display.

The STOPWATCH display mark will appear.

The STOPWATCH can measure up to 10 hours in hours, minutes, seconds and

1/100 seconds.

• Before using the stopwatch be sure to reset the digits to “0:00:00.00”.

When the stopwatch is stopped, press ”B” to reset.

When the stopwatch is counting, press “A” to stop the measurement

and then press “B”.

C

B A

Split/lap number

Split time

Lap time

Total time (accumulated elapsed time)

STOPWATCH display mark D

7

8

8-9

• “Split time” refers to an elapsed time required to cover a distance from

the start to a given point.

• “Lap time” refers to an elapsed time required to cover a given section

of the whole distance.

Lap time

Start

Split time

1. STANDARD MEASUREMENT

START

A

STOP

A B

RESET

2. ACCUMULATED ELAPSED TIME MEASUREMENT

START STOP

A A

RESTART

B

RESET

Hour Seconds

Minutes 1/100 seconds

STOP

A

Restart and stop of the stopwatch can be repeated by pressing “A”.

9

10-11

3. SPLIT TIME/LAP TIME MEASUREMENT

START

A B

SPLIT-LAP 1

Split time

Lap time

B

SPLIT-LAP 2

B

RESET

Split/lap number

STOP

A

Accumulated elapsed time

The split/lap time can be measured repeated

by pressing “B”.

SPLIT-LAP 8

B

Finish time

Note: When the number of stored measurements

exceeds 90, fl ashing “FULL” appears, and when

it exceeds 100, a warning sound starts beeping.

10

4. HOW TO USE THE MEMORY FUNCTION

The stopwatch can store up to 100 split times, 100 lap times and total elapsed time. They are automatically entered into the memory.

• With each press of “C”, the time stored is recalled. The time can be

recalled successively by keeping the button pressed.

C C C

B

“RECALL” more

A

C

Reset to “00” Finish time

• To stop the recall of the stored data, press “A”, “B”, or “D”. The

measurements when the stopwatch was stopped will be shown.

Then, press “B” to reset the digits to “00”.

11

12-13

• The time stored in the memory can be recalled even while the stopwatch

When the stopwatch is stopped

When the stopwatch is measuring

With each press of “C”

Split time and lap time are recalled starting with the fi rst ones.

The times are recalled starting with the last ones.

• To measure the lap time and split time while the stored data are being

recalled operate the buttons as follows.

B A

Press “B” to measure new lap time and split time.

Press “A” to stop the measurement.

Press “D” to return to the measurement mode.

Notes:

1. Even if the digits are reset to “00”, stored times are not erased and can be

recalled by pressing “C” unless new measurement is started.

2. If the stopwatch is left untouched with the recalled times shown, the display

will automatically return the STOPWATCH display in 1 to 20 minutes.

12

B

STOKE/FREQUENCY MEASURING

Press “D” to show the STROKE/FREQUENCY MEASURING display.

Start the measurement by pressing “A” and stop the measurement by pressing

“A” after the third stroke was made. The number of strokes per minute will be displayed.

Start Measuring Stop Reset

A A B

STROKE/

FREQUENCY

MEASURING mode

Start Stop

The number of strokes per minute

(23.2)

13

14-15

Notes:

1. During 1 second after the measurement has been started by pressing “A”,

fl ashing “180.0” is displayed. If the measurement is stopped by pressing

“A” during this period, “Err” will appear. If the measurement is not stopped

by pressing “A” after more than 18 seconds have elapsed, “Err” will

automatically appear. Therefore, note that measurable number of strokes

per minute is between 10 and 180.

Error

2. If “B” is pressed while the measurement is stopped or “Err” is shown, the

digits will be reset “0.0”. Even if the digits are not reset to “0.0” with the

measurement stopped or “Err” shown on the display, the measurement

can be started by pressing “A”.

14

REGISTER NOW

Please return your AX602FY Registration to the Repair Center address in the warranty, and we will let you know about future products.

Email (preferred)

User

NO-PROOF-OF-PURCHASE LIMITED WARRANTY

See label on back of unit for details, or check http://support.ACCUSPLIT.com

15

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement