Eliminate measurement errors with better isolation. Isolators with

Eliminate measurement errors with better isolation. Isolators with
Eliminate measurement errors with better isolation.
Isolators with exceptional performance for dedicated
applications
Our compact, fast and high-quality 6 mm isolators provide you with exceptionally high, safe signal
isolation, no matter the type of signal. They can be stacked both vertically and horizontally with no
air gap separation required, accommodating up to 50 units or 100 channels in just 30 centimeters.
All our isolators offer high isolation levels and exceptional EMC performance, utilizing our patented
technology to provide high basic accuracy, low power consumption, and maximum protection
against error due to electromagnetic noise (EMC).
Isolation
Isolation
3103 – Isolated repeater
E.2
3104 – Isolated converter
E.4
3105 – Isolated converter
E.6
3108 – Isolated repeater / splitter
E.8
3109 – Isolated converter / splitter E.10
3114 – Isolated universal converter E.12
3117 – Bipolar isolated converter E.14
3118 – Bipolar isolated converter / splitter E.16
3185 – Loop-powered isolator E.18
3186 – 2-wire transmitter isolator E.20
5104A – Repeater / power supply E.22
5106A – HART® transparent repeater E.24
6185 – Loop-powered isolator E.26
9106A - HART transparent repeater E.28
9107A – HART transparent driver E.30
9202A – Pulse Isolator E.32
9203A – Solenoid / alarm driver E.34
2204 – Isolation amplifier E.36
2279 – AC/DC transmitter E.38
E
2284 – Isolation amplifier E.40
E.1
Isolated repeater
3103
– Isolation and 1:1 conversion of standard current signals
– Slimline housing of 6 mm
– Response time < 7 ms
– Low cost
– Simple - no setup needed
Application
• Isolation and 1:1 conversion of standard current signals.
• Galvanic separation of analog current signals.
• Elimination of ground loops and measurement of floating
signals.
• A competitive choice in terms of both price and technology for
galvanic isolation of current signals to SCADA systems or
PLC equipment.
• Installation in ATEX Ex zone 2 / IECEx Zone 2 / FM division
2.
• Suitable for environments with high vibration stress, e.g.
ships.
E
Connections
Technical characteristics
• The input is protected against overvoltage and polarity error.
• Factory-calibrated measurement ranges.
• Inputs and outputs are floating and galvanically separated.
E.2
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Vibration: 2...25 Hz........................................ ±1.6 mm
Vibration: 25...100 Hz.................................... ±4 g
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
Signal / noise ratio.........................................
Response time (0...90%, 100...10%).............
Accuracy........................................................
Output specifications
Current output: Signal range.........................
Load (max.)....................................................
Load stability, current output..........................
Current limit....................................................
*of span..........................................................
0...20.5 mA (span)
23 mA/600 Ω
≤0.01% of span / 100 Ω
≤ 28 mA
= 0...20 mA
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
UL................................................................... UL 61010-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
EAC TR-CU 020/2011................................... EN 61326-1
EAC Ex TR-CU 012/2011.............................. RU C-DK.GB08.V.00410
CCOE............................................................. P337347/1
16.8...31.2 VDC
0.8 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
> 60 dB
< 7 ms
Better than 0.05% of selected
range
< ±0.01% of span / °C
< ±0.5% of span
E
Temperature coefficient.................................
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Current input: Measurement
range.............................................................. 0...20.5 mA
Functional range, current
input............................................................... 0...23 mA
Input voltage drop.......................................... < 1.5 VDC
3103-031015
E.3
Isolated converter
3104
– Isolation and conversion of standard DC signals
– Slimline housing of 6 mm
– Power supply and signal isolator for 2-wire transmitter
– Loop supply >17 V
– DIP-switch configured
Application
• Isolation and conversion of standard DC signals.
• Galvanic separation of analog current and voltage signals.
• Elimination of ground loops and measurement of floating
signals.
• A competitive choice in terms of both price and technology for
galvanic isolation of current and voltage signals to SCADA
systems or PLC equipment.
• Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2.
• Suitable for environments with high vibration stress, e.g.
ships.
E
Connections
Technical characteristics
• Easy configuration via DIP-switches.
• The input is protected against overvoltage and polarity error.
• Factory-calibrated measurement ranges.
• Inputs and outputs are floating and galvanically separated.
E.4
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Vibration: 2...25 Hz........................................ ±1.6 mm
Vibration: 25...100 Hz.................................... ±4 g
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
Signal / noise ratio.........................................
Response time (0...90%, 100...10%).............
Accuracy........................................................
16.8...31.2 VDC
1.2 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
> 60 dB
< 7 ms
Better than 0.05% of selected
range
< ±0.01% of span / °C
< ±0.5% of span
Output specifications
Current output: Signal range......................... 0...20.5 mA (span)
Programmable current ranges....................... 0 / 4...20 mA
Load (max.).................................................... 23 mA/600 Ω
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... ≤ 28 mA
Voltage output: signal range.......................... 0...10 VDC
Programmable voltage ranges....................... 0/1...5 and 0/2...10 V
Load (min.)..................................................... > 10 kΩ
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
EAC Ex TR-CU 012/2011.............................. RU C-DK.GB08.V.00410
CCOE............................................................. P337347/1
E
Temperature coefficient.................................
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Current input: Measurement
range.............................................................. 0...20.5 mA
Functional range, current
input............................................................... 0...23 mA
Current input: Programmable
measurement ranges..................................... 0...20 and 4...20 mA
Input voltage drop.......................................... < 1.5 VDC
2-wire transmitter supply................................ > 17 V / 20 mA
Voltage input: Measurement
range.............................................................. 0...10.25 V
Functional range, voltage
input............................................................... 0...11.5 V / 0...5.75 V
Programmable measurement ranges,
VDC................................................................ 0/1...5 and 0/2...10 V
Input resistance, voltage
input............................................................... ≥ 500 kΩ
3104-031315
E.5
Isolated converter
3105
– Isolation and conversion of standard DC signals
– Slimline housing of 6 mm
– Response time <7 ms
– Low cost
– DIP-switch configured
Application
• Isolation and conversion of standard DC signals.
• Galvanic separation of analog current and voltage signals.
• Elimination of ground loops and measurement of floating
signals.
• A competitive choice in terms of both price and technology for
galvanic isolation of current and voltage signals to SCADA
systems or PLC equipment.
• Suitable for environments with high vibration stress, e.g.
ships.
E
Connections
Technical characteristics
• Easy configuration via DIP-switches.
• The input is protected against overvoltage and polarity error.
• Factory-calibrated measurement ranges.
• Inputs and outputs are floating and galvanically separated.
E.6
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
0°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Vibration: 2...25 Hz........................................ ±1.6 mm
Vibration: 25...100 Hz.................................... ±4 g
Output specifications
Current output: Signal range......................... 0...20.5 mA (span)
Programmable current ranges....................... 0 / 4...20 mA
Load (max.).................................................... 23 mA/600 Ω
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... ≤ 28 mA
Voltage output: signal range.......................... 0...10 VDC
Programmable voltage ranges....................... 0/1...5 and 0/2...10 V
Load (min.)..................................................... > 10 kΩ
*of span.......................................................... = of the DIP-switch selected
output range
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 508
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
Signal / noise ratio.........................................
Response time (0...90%, 100...10%).............
Accuracy........................................................
16.8...31.2 VDC
0.8 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC
> 60 dB
< 7 ms
Better than 0.2% of selected
range
Temperature coefficient................................. < ±0.015% of span / ˚C
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
E
Input specifications
Current input: Measurement
range.............................................................. 0...20.5 mA
Functional range, current
input............................................................... 0...23 mA
Current input: Programmable
measurement ranges..................................... 0...20 and 4...20 mA
Input voltage drop.......................................... < 1.5 VDC
Voltage input: Measurement
range.............................................................. 0...10.25 V
Functional range, voltage
input............................................................... 0...11.5 V / 0...5.75 V
Programmable measurement ranges,
VDC................................................................ 0/1...5 and 0/2...10 V
Input resistance, voltage
input............................................................... ≥ 500 kΩ
3105-031015
E.7
Isolated repeater / splitter
3108
– Isolation and conversion of current signals
– Slimline housing of 6 mm
– Response time <7 ms
– Splitter function: 1 in - 2 out
– Simple - no setup needed
Application
• Isolation and conversion of standard DC signals.
• Galvanic separation of analog current signals.
• Elimination of ground loops and measurement of floating
signals.
• A competitive choice in terms of both price and technology for
galvanic isolation of current signals to SCADA systems or
PLC equipment.
• Installation in ATEX Ex zone 2 / IECEx Zone 2 / FM division
2.
• Suitable for environments with high vibration stress, e.g.
ships.
E
Connections
Technical characteristics
• The input is protected against overvoltage and polarity error.
• Factory-calibrated measurement ranges.
• Inputs and outputs are floating and galvanically separated.
E.8
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Vibration: 2...25 Hz........................................ ±1.6 mm
Vibration: 25...100 Hz.................................... ±4 g
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
Signal / noise ratio.........................................
Response time (0...90%, 100...10%).............
Accuracy........................................................
Output specifications
Current output: Signal range.........................
Load (max.)....................................................
Load stability, current output..........................
Current limit....................................................
*of span..........................................................
0...20.5 mA (span)
23 mA/300 Ω
≤0.01% of span / 100 Ω
≤ 28 mA
= 0...20 mA
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
EAC Ex TR-CU 012/2011.............................. RU C-DK.GB08.V.00410
CCOE............................................................. P337347/1
16.8...31.2 VDC
0.8 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
> 60 dB
< 7 ms
Better than 0.05% of selected
range
< ±0.01% of span / °C
< ±0.5% of span
E
Temperature coefficient.................................
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Current input: Measurement
range.............................................................. 0...20.5 mA
Functional range, current
input............................................................... 0...23 mA
Input voltage drop.......................................... < 1.5 VDC
3108-031315
E.9
Isolated converter / splitter
3109
– Isolation and conversion of standard DC signals
– Slimline housing of 6 mm
– Power supply and signal isolator for 2-wire transmitter
– Splitter function: 1 in - 2 out
– DIP-switch configured
Application
• Isolation and conversion of standard DC signals.
• Galvanic separation of analog current and voltage signals.
• Elimination of ground loops and measurement of floating
signals.
• A competitive choice in terms of both price and technology for
galvanic isolation of current and voltage signals to SCADA
systems or PLC equipment.
• Installation in ATEX Ex zone 2 / IECEx zone 2 / FM division 2.
• Suitable for environments with high vibration stress, e.g.
ships.
E
Connections
Technical characteristics
• Easy configuration via DIP-switches.
• The input is protected against overvoltage and polarity error.
• Factory-calibrated measurement ranges.
• Inputs and outputs are floating and galvanically separated.
E.10
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Vibration: 2...25 Hz........................................ ±1.6 mm
Vibration: 25...100 Hz.................................... ±4 g
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
Signal / noise ratio.........................................
Response time (0...90%, 100...10%).............
Accuracy........................................................
16.8...31.2 VDC
1.2 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
> 60 dB
< 7 ms
Better than 0.05% of selected
range
< ±0.01% of span / °C
< ±0.5% of span
Output specifications
Current output: Signal range......................... 0...20.5 mA (span)
Programmable current ranges....................... 0 / 4...20 mA
Load (max.).................................................... 23 mA/300 Ω
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... ≤ 28 mA
Voltage output: signal range.......................... 0...10 VDC
Programmable voltage ranges....................... 0/1...5 and 0/2...10 V
Load (min.)..................................................... > 10 kΩ
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
EAC Ex TR-CU 012/2011.............................. RU C-DK.GB08.V.00410
CCOE............................................................. P337347/1
E
Temperature coefficient.................................
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Current input: Measurement
range.............................................................. 0...20.5 mA
Functional range, current
input............................................................... 0...23 mA
Current input: Programmable
measurement ranges..................................... 0...20 and 4...20 mA
Input voltage drop.......................................... < 1.5 VDC
2-wire transmitter supply................................ > 17 V / 20 mA
Voltage input: Measurement
range.............................................................. 0...10.25 V
Programmable measurement ranges,
VDC................................................................ 0/1...5 and 0/2...10 V
Functional range, voltage
input............................................................... 0...11.5 V / 0...5.75 V
Input resistance, voltage
input............................................................... ≥ 500 kΩ
3109-031015
E.11
Isolated universal converter
3114
– Input for RTD, TC, Ohm, potentiometer, mA and V
– Slimline housing of 6 mm
– 2-wire supply >15 V
– Output for current and voltage
– Can be supplied separately or installed on power rail, PR 9400
Application
• Linearized, electronic temperature measurement with RTD or
TC sensor.
• Conversion of linear resistance variation to a standard analog
current / voltage signal, i.e. from solenoids and butterfly
valves or linear movements with attached potentiometer.
• Power supply and signal isolator for 2-wire transmitters.
• Process control with standard analog output.
• Galvanic separation of analog signals and measurement of
floating signals.
• The device can be mounted in Safe area or in Zone 2 and Cl.
1 Div 2. area.
E
Connections
Advanced features
• When 3114 is used in combination with the 4501 display /
programming front and ConfigMate 4590, all operational
parameters can be modified to suit any application.
Technical characteristics
• A green / red front LED indicates normal operation and
malfunction.
• 3-port 2.5 kVAC galvanic isolation.
E.12
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Vibration: 2...25 Hz........................................ ±1.6 mm
Vibration: 25...100 Hz.................................... ±4 g
Common specifications
Supply voltage...............................................
Fuse...............................................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
16.8...31.2 VDC
400 mA SB / 250 VAC
1.2 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
Signal / noise ratio......................................... > 60 dB
Response time (0...90%, 100...10%):
Temperature input.......................................... ≤ 1 s
Response time (0...90%, 100...10%):
mA / V input.................................................... ≤ 400 ms
Accuracy........................................................ Better than 0.1% of selected
range
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Voltage input: Measurement
range.............................................................. 0...12 VDC
Programmable measurement ranges,
VDC................................................................ 0/0.2...1, 0/1...5, 0/2...10 VDC
Input resistance, voltage
input............................................................... Nom. 10 MΩ
Output specifications
Current output: Signal range......................... 0…20 mA (span)
Programmable current ranges....................... 0...20 / 4...20 / 20...0 and
20...4 mA
Load (max.).................................................... 20 mA/600 Ω/15 VDC
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Sensor error indication, current
output............................................................. 0 / 3.5 / 23 mA / none
NAMUR NE 43 Upscale/Downscale.............. 23 mA / 3.5 mA
Current limit.................................................... ≤ 28 mA
Voltage output: signal range.......................... 0...10 VDC
Programmable voltage ranges....................... 0/0.2...1; 0/1...5 ; 0/2...10;
1...0.2/0; 5...1/0; 10...2/0 V
Load (min.)..................................................... > 10 kΩ
*of span.......................................................... = of the currently selected
measurement range
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
EAC Ex TR-CU 012/2011.............................. RU C-DK.GB08.V.00410
CCOE............................................................. P337347/1
E
Input specifications
3114-031015
RTD input....................................................... Pt10, Pt20, Pt50, Pt100,
Pt200, Pt250, Pt300, Pt400,
Pt500, Pt1000, Ni50, Ni100,
Ni120, Ni1000
Cable resistance per wire
(max.), RTD.................................................... 50 Ω
Sensor current, RTD...................................... Nom. 0.2 mA
Effect of sensor cable resistance
(3-/4-wire), RTD............................................. < 0.002 Ω / Ω
Sensor error detection, RTD.......................... Yes
Short circuit detection, RTD........................... < 15 Ω
TC input: Thermocouple type......................... B, E, J, K, L, N, R, S, T, U,
W3, W5, LR
CJC via internally mounted
sensor............................................................ ±(2.0°C + 0.4°C * Δt)
Δt =................................................................. Internal temperature-ambient
temperature
Sensor error detection, TC............................. Yes
Sensor error current: When
detecting / else............................................... Nom. 2 μA / 0 μA
Current input: Measurement
range.............................................................. 0...20 mA
Current input: Programmable
measurement ranges..................................... 0...20 and 4...20 mA
Input resistance, current
input............................................................... Nom. 20 Ω + PTC 50 Ω
2-wire transmitter supply................................ > 15 V / 20 mA
E.13
Bipolar isolated converter
3117
– Conversion of voltage and current bipolar process signals to unipolar
signals
– Multiple signal ranges are selectable via DIP-switches
– Fast response time < 7 ms and high output load stability
– Excellent accuracy, better than 0.05 % of selected range
– Slimline 6 mm housing
Application
• The 3117 is an isolating converter which can be used for
signal conversion of standard bipolar analog process signals
into a unipolar analog signal.
• The unit offers 3-port isolation and provides surge
suppression and protects control systems from transients and
noise.
• The 3117 also eliminates ground loops and can be used for
measuring floating signals.
• Mounting of the 3117 can be in Safe area or in Zone 2 and Cl.
1 Div 2 area and is approved for marine applications.
E
Connections
Technical characteristics
• Flexible 24 VDC (±30%) supply via power rail or connectors.
• Excellent conversion accuracy, better than 0.05% of selected
range.
• Inputs and outputs are floating and galvanically separated.
• A green front LED indicates operation status for the device.
• All terminals are protected against overvoltage and polarity
error.
• Meeting the NAMUR NE21 recommendations, the 3117
ensures top measurement performance in harsh EMC
environments.
• High galvanic isolation of 2.5 kVAC.
• Fast input to output response time < 7 ms / > 100 Hz – 10 Hz
bandwidth damping possible via DIP-switch.
• Excellent signal/noise ratio > 60 dB.
Mounting / installation / programming
• Fast and easy configuration of factory calibrated
measurement ranges via DIP-switches.
• A very low power consumption allows DIN rail mounting
without the need for any air gap.
• Wide temperature operation range: -25...+70°C.
E.14
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
MTBF, acc. to IEC 61709 (SN29500)............
Signal / noise ratio.........................................
Cut-off frequency (3 dB).................................
16.8...31.2 VDC
0.8 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
> 241 years
> 60 dB
> 100 Hz or 10 Hz (selectable
via DIP-switch)
< 7 ms or < 44 ms
< ±0.05% of span
< ±0.01% of span / °C
< ±0.5% of span
Output specifications
Programmable current ranges....................... 0 / 4...20 mA
Functional range, current
output............................................................. 0...23 mA
Load (max.).................................................... 23 mA/600 Ω
Load stability, current output.......................... ≤ 0.002% of span / 100 Ω
Current limit.................................................... ≤ 28 mA
Programmable voltage ranges....................... 0/1...5 and 0/2...10 V
Functional range, voltage
output............................................................. 0...11.5 V
Load (min.)..................................................... > 10 kΩ
*of span.......................................................... = of the presently selected
range
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
E
Response time (0...90%, 100...10%).............
Accuracy........................................................
Temperature coefficient.................................
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Current input: Programmable
measurement ranges.....................................
Functional range, current
input...............................................................
Input voltage drop..........................................
Voltage input: Programmable
ranges............................................................
Functional range, voltage
input...............................................................
Input resistance, voltage
input...............................................................
± 10 and ± 20 mA
-23...+23 mA
< 1 VDC @ 23 mA
±5 and ±10 V
-11.5...+11.5 V
≥ 1 MΩ
3117-031315
E.15
Bipolar isolated converter / splitter
3118
– Conversion of voltage and current bipolar process signals to<br />
uni-/bipolar signals
– Multiple signal ranges are selectable via DIP-switches
– Splitter function: 1 signal in and 2 signals out
– Excellent accuracy, better than 0.05 % of selected range and high
output load stability
Application
• The 3118 is an isolating converter and splitter which can be
used for signal conversion of standard bipolar analog process
signals into two individual unipolar analog signals.
• The unit offers 4-port isolation and provides surge
suppression and protects control systems from transients and
noise.
• The 3118 also eliminates ground loops and can be used for
measuring floating signals.
• Mounting of the 3118 can be in Safe area or in Zone 2 and Cl.
1 Div 2 area and is approved for marine applications.
• The analog output can be easily configured and programmed
to be bipolar in the ranges ±10 mA and ±20 mA (*special
setup).
E
Connections
Technical characteristics
• Flexible 24 VDC (±30%) supply via power rail or connectors.
• Excellent conversion accuracy, better than 0.05% of selected
range.
• A green front LED indicates operation status for the device.
• All terminals are protected against overvoltage and polarity
error.
• Meeting the NAMUR NE21 recommendations, the 3118
ensures top measurement performance in harsh EMC
environments.
• High galvanic isolation of 2.5 kVAC.
• Fast input to output response time < 7 ms / > 100 Hz – 10 Hz
bandwidth damping possible via DIP-switch.
• Excellent signal/noise ratio > 60 dB.
Mounting / installation / programming
• Easy configuration of factory calibrated measurement ranges
via DIP-switches.
• A very low power consumption allows DIN rail mounting
without the need for any air gap.
• Wide temperature operation range: -25...+70°C.
E.16
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
Screw terminal torque.................................... 0.5 Nm
Common specifications
Supply voltage...............................................
Max. power consumption...............................
Internal consumption......................................
Isolation voltage, test.....................................
Isolation voltage, working...............................
MTBF, acc. to IEC 61709 (SN29500)............
Signal / noise ratio.........................................
Cut-off frequency (3 dB).................................
16.8...31.2 VDC
0.8 W
0.4 W (typ.) / 0.65 W (max.)
2.5 kVAC
300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
> 187 years
> 60 dB
> 100 Hz or 10 Hz (selectable
via DIP-switch)
< 7 ms or < 44 ms
< ±0.05% of span
< ±0.01% of span / °C
< ±0.5% of span
Output specifications
Programmable current ranges....................... 0 / 4...20 mA
Functional range, current
output............................................................. 0...23 mA
Load (max.).................................................... 23 mA / 300 Ω / per ch.
Load stability, current output.......................... ≤ 0.002% of span / 100 Ω
Current limit.................................................... ≤ 28 mA
Programmable voltage ranges....................... 0/1...5 and 0/2...10 V
Functional range, voltage
output............................................................. 0...11.5 V
Load (min.)..................................................... > 10 kΩ
Bipolar wiring and programming
set-up............................................................. ±10 and ± 20 mA
*of span.......................................................... = of the presently selected
range
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
E
Response time (0...90%, 100...10%).............
Accuracy........................................................
Temperature coefficient.................................
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Current input: Programmable
measurement ranges.....................................
Functional range, current
input...............................................................
Input voltage drop..........................................
Voltage input: Programmable
ranges............................................................
Functional range, voltage
input...............................................................
Input resistance, voltage
input...............................................................
± 10 and ± 20 mA
-23...+23 mA
< 1 VDC @ 23 mA
±5 and ±10 V
-11.5...+11.5 V
≥ 1 MΩ
3118-031315
E.17
Loop powered isolator
3185
– 1 or 2 channel input loop powered isolator
– Signal 1:1 functional range 0...23 mA
– Low input voltage drop and fast response time
– Excellent accuracy and high load stability
– Slimline 6 mm housing
Application
• 1:1 input loop powered isolator of current signals in the range
0(4)...20 mA.
• 3185 is an easy mounting DIN rail unit.
• A very competitive choice in terms of both price and
technology for galvanic isolation of current signals.
• Provides surge suppression and protects control systems
from transients and noise.
• 3185 eliminates ground loops and can be used for measuring
floating signals.
• The device can be mounted in Safe area or in Zone 2 and Cl.
1 Div 2. area.
E
Connections
Technical characteristics
• 3185 is powered by the analog input current signal loop.
• Low input voltage drop, typ 1.35 V + Vout.
• Excellent conversion accuracy, better than 0.1% in the range
0…20.5 mA.
• Functional range is 0...23 mA which means that 3185 is
NAMUR NE43 compliant.
• Inputs and outputs are floating and galvanically separated.
• The output is voltage limited to 17.5 VDC.
• High galvanic isolation of 2.5 kVAC.
• Fast response time < 5 ms.
• Excellent signal/noise ratio > 60 dB.
Mounting / installation / programming
• DIN rail mounting with up to 330 channels per meter.
• Temperature operation range is from -25...+70°C.
E.18
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
Vibration.........................................................
Vibration: 2...25 Hz........................................
Vibration: 25...100 Hz....................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
0.5 Nm
IEC 60068-2-6 : 2007
±1.6 mm
±4 g
Output specifications
Output load, max............................................ 600 Ω
Output load stability....................................... < 0.01% of span / 100 Ω
Voltage limit.................................................... 17.5 V
*of span.......................................................... = 0...20 mA
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
EAC TR-CU 020/2011................................... EN 61326-1
CCOE............................................................. P337347/1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
Common specifications
Internal consumption, per
channel........................................................... 30 mW
Isolation voltage, test..................................... 2.5 kVAC
Isolation voltage, working............................... 300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
Signal / noise ratio......................................... > 60 dB
Accuracy........................................................ Better than 0.1% of selected
range
Cut-off frequency (3 dB)................................. 100 Hz
Response time (0...90%, 100...10%)............. < 5 ms
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Signal range, input to output..........................
Signal conversion...........................................
Functional range, current
input...............................................................
Start up current, typ.......................................
Current input overload, max...........................
Input to output voltage drop,
typ..................................................................
Input to output voltage drop,
typ..................................................................
Input voltage drop..........................................
E
0...20.5 mA
1:1
0...23 mA
10 uA
50 mA
1.25 V + (0.015 x Vout.)
(Vout. = Iout.xRoutput load)
(Unit voltage drop) + Vout.
3185-031315
E.19
2-wire transmitter isolator
3186
– 1 or 2 channel 2-wire transmitter isolator
– Signal 1:1 functional range 3.5...23 mA
– Low channel voltage drop and fast response time
– Excellent accuracy
– Slimline 6 mm housing
Application
• 1:1 output loop powered isolator of 2-wire transmitter 4...20
mA signals.
• 3186 is an easy mounting DIN rail unit.
• A very competitive choice in terms of both price and
technology for galvanic isolation of 2-wire transmitter signals.
• Provides surge suppression and protects control systems
from transients and noise.
• 3186 eliminates ground loops and can be used for measuring
floating signals.
• The device can be mounted in Safe area or in Zone 2 and Cl.
1 Div 2. area.
E
Connections
Technical characteristics
• 3186 is powered by the host loop voltage.
• Wide supply range from 6...35 V.
• Low input to output voltage drop typ. 2.5 V.
• Excellent conversion accuracy, better than 0.05% in the range
3.8…20.5 mA.
• Functional range is 3.5...23 mA which means that 3186 is
NAMUR NE43 compliant.
• Inputs and outputs are floating and galvanically separated.
• High galvanic isolation of 2.5 kVAC.
• Fast response time < 5 ms.
• Excellent signal/noise ratio > 60 dB.
Mounting / installation / programming
• DIN rail mounting with up to 330 channels per meter.
• Temperature operation range is from -25...+70°C.
E.20
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
Vibration.........................................................
Vibration: 2...25 Hz........................................
Vibration: 25...100 Hz....................................
-25°C to +70°C
-40°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
113 x 6.1 x 115 mm
70 g
DIN EN 60715/35 mm
0.13 x 2.5 mm2 / AWG 26...12
stranded wire
0.5 Nm
IEC 60068-2-6 : 2007
±1.6 mm
±4 g
Output specifications
Output loop current limitation,
typ.................................................................. 24 mA
Current output overload, max........................ 50 mA
*of span.......................................................... = 4...20 mA
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
ATEX 2004/108/EC........................................ KEMA 10ATEX0147 X, II 3 G
Ex nA IIC T4 Gc
IECEx............................................................. KEM 10.0068X
FM.................................................................. 3041043-C
CCOE............................................................. P337347/1
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
GL.................................................................. V1-7-2
UL................................................................... UL 61010-1
Common specifications
Supply voltage............................................... 6...35 VDC
Internal consumption, per
channel........................................................... 50 mW
Isolation voltage, test..................................... 2.5 kVAC
Isolation voltage, working............................... 300 VAC (reinforced) / 250
VAC (Zone 2, Div. 2)
Signal / noise ratio......................................... > 60 dB
Accuracy........................................................ Better than 0.05% of selected
range
Cut-off frequency (3 dB)................................. 100 Hz
Response time (0...90%, 100...10%)............. < 5 ms
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
E
Input specifications
Available 2-wire transmitter
(Tx) supply.....................................................
Signal range, input to output..........................
Signal conversion...........................................
Functional range, current
input...............................................................
3.5...32.5 V
3.8...20.5 mA
1:1
3.5...23 mA
3186-031015
E.21
Repeater / power supply
5104A
– 1- or 2-channel version
– 3- / 5-port 3.75 kVAC galvanic isolation
– Loop supply > 17.1 V
– 20 programmable measurement ranges
– Universal supply by AC or DC
Application
• Power supply and signal isolator for 2-wire transmitters.
• Signal isolator for analog current / voltage signals.
• 1 : 1 or signal conversion of analog current / voltage signals.
Connections
Technical characteristics
• The 20 factory-calibrated measurement ranges in the 5104A
can be selected by the internal DIP-switches without the need
for recalibration. Special measurement ranges can be
delivered.
• PR5104A is based on microprocessor technology for gain and
offset. The analog signal is transmitted at a response time of
less than 25 ms.
• Inputs, outputs, and supply are floating and galvanically
separated.
• The output can be connected either as an active current /
voltage transmitter or as a 2-wire transmitter.
E
Mounting / installation
• Mounted vertically or horizontally on a DIN rail. By way of the
2-channel version up to 84 channels per meter can be
mounted.
E.22
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP20
109 x 23.5 x 130 mm
225 g
DIN 46277
1 x 2.5 mm2 stranded wire
0.5 Nm
Common specifications
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Fuse............................................................... 400 mA SB / 250 VAC
Max. power consumption............................... ≤ 3 W (2 channels)
Internal consumption...................................... ≤ 2 W (2 channels)
Isolation voltage, test /
working........................................................... 3.75 kVAC / 250 VAC
Signal / noise ratio......................................... Min. 60 dB (0...100 kHz)
Response time (0...90%, 100...10%)............. < 25 ms
Auxiliary supply: 2-wire supply
(pin 44...42 and 54...52)................................. 28...17.1 VDC / 0...20 mA
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Output specifications
Max. offset...................................................... 20% of max. value
Current output: Signal range......................... 0...20 mA
Min. signal range............................................ 16 mA
Load (max.).................................................... 20 mA/600 Ω/12 VDC
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... ≤ 28 mA
Max. external 2-wire supply........................... 29 VDC
Effect of external 2-wire
supply voltage variation................................. < 0.005% of span / V
Voltage output: signal range.......................... 0...1 VDC / 0...10 VDC
Voltage output, min. signal
range.............................................................. 0.8 VDC / 8 VDC
Load (min.)..................................................... 500 kΩ
*of span.......................................................... = of the presently selected
range
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
PELV/SELV.................................................... IEC 364-4-41 and EN 60742
UL................................................................... UL 508
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
E
Input specifications
Max. offset...................................................... 20% of max. value
Current input: Measurement
range.............................................................. 0...20 mA
Min. measurement range (span),
current input................................................... 16 mA
Input resistance, current
input............................................................... Nom. 10 Ω + PTC 10 Ω
Voltage input: Measurement
range.............................................................. 0...10 VDC
Min. measurement range (span),
voltage input................................................... 8 VDC
Input resistance, voltage
input............................................................... > 2 MΩ
5104A-031915
E.23
HART® transparent repeater
5106A
– 3- / 5-port 3.75 kVAC galvanic isolation
– Low response time
– 2-wire supply > 17 V
– 1- or 2-channel version
– Universal supply by AC or DC
Application
• Power supply and signal isolator with 2-way HART®
communication for 2-wire transmitters installed in the
hazardous area.
• Signal isolator with 2-way HART® communication for supplied
current transmitters installed in the hazardous area.
• Signal isolator with low response time on analog current
signals.
Connections
Technical characteristics
• PR5106A primarily processes current signals of 4...20 mA.
• PR5106A is based on microprocessor technology for gain and
offset. The analog signal is transmitted at a response time of
less than 25 ms.
• Inputs, outputs, and supply are floating and galvanically
separated.
• The output can be connected either as an active current
transmitter or as a 2-wire transmitter.
E
Mounting / installation
• Mounted vertically or horizontally on a DIN rail. As the devices
can be mounted without distance between neighboring units,
up to 84 channels can be mounted per meter.
E.24
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Mechanical specifications
Dimensions (HxWxD).....................................
Weight approx................................................
Weight approx................................................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP20
109 x 23.5 x 130 mm
65 g
245 g
DIN 46277
1 x 2.5 mm2 stranded wire
0.5 Nm
Common specifications
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Fuse............................................................... 400 mA SB / 250 VAC
Max. power consumption............................... ≤ 3 W (2 channels)
Internal consumption...................................... ≤ 2 W (2 channels)
Isolation voltage, test /
working........................................................... 3.75 kVAC / 250 VAC
Signal / noise ratio......................................... Min. 60 dB (0...100 kHz)
Accuracy........................................................ Better than 0.1% of selected
range
Response time (0...90%, 100...10%)............. < 25 ms
Effect of supply voltage change..................... < ±10 μA
Auxiliary supply: 2-wire supply
(pin 44...42 and 54...52)................................. 25...17 VDC / 0...20 mA
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Output specifications
Current output: Signal range......................... 4…20 mA
2-wire 4...20 mA output: Signal
range.............................................................. 4...20 mA
Min. signal range............................................ 16 mA
Load (max.).................................................... 20 mA/600 Ω/12 VDC
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... ≤ 28 mA
Effect of external 2-wire
supply voltage variation................................. < 0.005% of span / V
Output ripple................................................... < 3 mVRMS on HART
communication
Max. external 2-wire supply........................... 29 VDC
*of span.......................................................... = of the presently selected
range
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
PELV/SELV.................................................... IEC 364-4-41 and EN 60742
UL................................................................... UL 508
EAC TR-CU 020/2011................................... EN 61326-1
E
Input specifications
Current input: Measurement
range..............................................................
Min. measurement range (span),
current input...................................................
Input resistance: Supplied
unit.................................................................
Input resistance: Non-supplied
unit.................................................................
4...20 mA
16 mA
Nom. 10 Ω
Rshunt = ∞, Vdrop < 4 V
5106A-031915
E.25
Loop-powered isolator
6185
– 1-, 2- and 4-channel galvanic isolation
– Slimline channel width of less than 6 mm
– No separate supply necessary
– Low response time
– High noise suppression
Application
• Galvanic separation of analog current signals.
• Elimination of ground loops and measurement of floating
signals.
• A competitive choice in terms of both price and technology for
galvanic isolation of current signals to SCADA systems or
PLC equipment.
• Especially useful in applications necessitating an
unproblematic transmission of current signals according to
NAMUR (sensor error detection).
E
Connections
Technical characteristics
• PR 6185 is powered by the measured signal and loads the
loop with max. 1.8 VDC.
• The input is protected against overvoltage and polarity error.
• The drop voltage for each channel can be calculated
according to the following expression: Vdrop = 1.8 + (Iout. *
Rload.
• The output is voltage-limited to 15 VDC.
• Inputs and outputs are floating and galvanically separated.
Mounting / installation
• Mounted vertically or horizontally on a DIN rail. As the devices
can be mounted without distance between neighboring units,
up to 168 channels can be mounted per meter.
E.26
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP20
Mechanical specifications
Dimensions (HxWxD)..................................... 109 x 23.5 x 104 mm
Weight approx................................................ 155 / 180 / 230 g (1 / 2 / 4
channels)
DIN rail type................................................... DIN 46277
Wire size........................................................ 1 x 2.5 mm2 stranded wire
Screw terminal torque.................................... 0.5 Nm
Output specifications
Current output: Signal range......................... 0...23 mA
Min. signal range............................................ 1:1
Load (max.).................................................... 20 mA/600 Ω/12 VDC
Load stability, current output.......................... < 0.03% of span / 100 Ω
Current limit.................................................... 50 mA
Voltage limit.................................................... 15 VDC
*of span.......................................................... = of the presently selected
range
Approvals
EMC............................................................... EN 61326-1
EAC TR-CU 020/2011................................... EN 61326-1
Common specifications
Internal consumption, per
channel........................................................... 40 mW
Voltage drop................................................... < 1.8 VDC, min.
Voltage drop................................................... 1.8 V + (Iout.*Rload), max.
Isolation voltage, test..................................... 2 kVAC
Signal / noise ratio......................................... Min. 60 dB (0...100 kHz)
Accuracy........................................................ Better than 0.1% of selected
range
Response time (0...90%, 100...10%)............. < 4 ms
EMC immunity influence................................ < ±0.5% of span
E
Input specifications
Current input: Measurement
range.............................................................. 0...23 mA
Input resistance, current
input............................................................... ≈ 90 Ω + Rload (@ 20 mA)
6185-031915
E.27
HART® transparent repeater
9106A
– 24 VDC supply via power rail or connectors
– Active and passive mA input
– Active or passive output via the same two terminals
– Splitter function - 1 in and 2 out
– SIL2 / SIL3 Full Assessment and certified acc. to IEC 61508
Application
• 9106A is a 1- or 2-channel isolated 1:1 repeater.
• The device supplies 2-wire SMART transmitters and can also
be used for 2-wire SMART current sources. HART® & BRAIN
protocols are supported and are transferred bi-directionally.
• 9106A can be mounted in and receive signals from nonclassified area or zone 2.
• The PR 4511/4501 displays the process value for each
channel and can be used to define high and low limits for
detection of loop current level. If these limits are exceeded,
the status relay will activate.
• In the 1-channel version the status relay can be used as a
simple limit switch.
• Splitter application - 1 input and 2 outputs.
• In the dual channel version the 9106A can be implemented in
a SIL3 loop.
E
Connections
Advanced features
• The detachable display and the green and red front LEDs
indicate operation status for each channel.
• A tag number can be defined for each channel.
• Monitoring of error events and cable breakage on input via
the individual status relay and/or a collective electronic signal
via the power rail.
Technical characteristics
• High galvanic isolation of 2.6 kVAC.
• Fast response time <5 ms
• High accuracy better than 0.1%.
• 2-wire transmitter supply >16 V.
Mounting
• The devices can be mounted vertically or horizontally without
distance between neighbouring units.
E.28
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
Mechanical specifications
Dimensions (HxWxD).....................................
Dimensions (HxWxD) w/ 4501
/ 4511.............................................................
Weight approx................................................
Weight incl. 4501 / 4511 (approx.).................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
Vibration.........................................................
Vibration: 2...13.2 Hz.....................................
Vibration: 13.2...100 Hz.................................
Common specifications
Supply voltage...............................................
Fuse...............................................................
Max. power consumption...............................
Max. internal power dissipation......................
Isolation voltage, test /working:
Input to any....................................................
-20°C to +60°C
-20°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
109 x 23.5 x 104 mm
109 x 23.5 x 116 / 131 mm
250 g
265 g / 350 g
DIN EN 60715/35 mm
0.13...2.08 mm2 AWG 26...14
stranded wire
0.5 Nm
IEC 60068-2-6 : 2007
±1 mm
±0.7 g
19.2...31.2 VDC
1.25 A SB / 250 VAC
≤ 3 W (2 channels)
≤ 2 W (2 channels)
Output specifications
Current output: Signal range.........................
Load (max.)....................................................
Load stability, current output..........................
Current limit....................................................
Effect of external 2-wire
supply voltage variation.................................
Max. load resistance [Ω]................................
Max. external 2-wire supply...........................
Status relay output terminal
33-34: Relay function.....................................
Programmable low setpoint...........................
Programmable high setpoint..........................
Hysteresis for setpoints..................................
Max. voltage, status relay..............................
Max. current, status relay...............................
Max. voltage - hazardous installation.............
Max. current - hazardous installation.............
*of span..........................................................
3.5...23 mA
20 mA/600 Ω/12 VDC
≤0.01% of span / 100 Ω
≤ 28 mA
< 0.005% of span / V
(Vsupply - 3.5) / 0.023 A
26 VDC
N.C.
0...29.9 mA
0...29.9 mA
0.1 mA
110 VDC / 125 VAC
0.3 ADC / 0.5 AAC
32 VDC / 32 VAC
1 ADC / 0.5 AAC
= normal measurement range
4...20 mA
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
UL................................................................... UL 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
SIL.................................................................. SIL 2 / SIL3 certified & fully
assessed acc. to IEC 61508
E
2.6 kVAC / 300 VAC
reinforced isolation
Analog output to supply................................. 2.6 kVAC / 300 VAC
reinforced isolation
Status relay to supply..................................... 1.5 kVAC / 150 VAC
reinforced isolation
SMART bi-directional communication
frequency range............................................. 0.5...7.5 kHz
Signal / noise ratio......................................... > 60 dB
Response time (0...90%, 100...10%)............. < 5 ms
Accuracy........................................................ Better than 0.1% of selected
range
mA, absolute accuracy................................... ≤ ±16 μA
mA, temperature coefficient........................... ≤ ±1.6 μA / °C
Effect of supply voltage change
on output (nom. 24 VDC)............................... < ±10 μA
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
3,5...23 mA
>16 V / 20 mA
>15 V / 20 mA
< 1 mA
< 4 V @ 23 mA
< 6 V @ 23 mA
9106A-060215
Current input: Measurement
range..............................................................
2-wire transmitter supply
9106A1x.........................................................
2-wire transmitter supply
9106A2x.........................................................
Sensor error detection: Loop
break 4...20 mA..............................................
Input voltage drop, supplied
unit.................................................................
Input voltage drop, non-supplied
unit.................................................................
E.29
HART® transparent driver
9107A
– 24 VDC supply via power rail or connectors
– Fast response time
– High active output load 725 Ohm / 20 mA
– Output line fault detection via status relay
– SIL2 certified via Full Assessment according to IEC 61508
Application
• 9107A is a 1- or 2-channel isolated 1:1 driver.
• Operation and drive control of I/P converters, valves and
indicators.
• Operation of HART® devices is possible as the unit transmits
HART® communication signals bi-directionally.
• The device can be mounted in and transmit signals to nonclassified area and zone 2.
• The PR 4511/4501 displays the process value for each
channel and can be used to define high and low limits for
detection of loop current level. If these limits are exceeded,
the status relay will activate.
• Dual channel versions can be used for signal splitter
applications - 1 in and 2 out.
E
Connections
Advanced features
• The PR 4511/4501 detachable display and the green and red
front LEDs indicate operation status for each channel.
• A tag number can be defined for each channel.
• Output line fault detection.
• In the 1-channel version the status relay can be used as a
simple limit switch.
Technical characteristics
• High galvanic isolation of 2.6 kVAC.
• High accuracy better than 0.1%.
• Continuous check of vital stored data for safety reasons.
Mounting
• The devices can be mounted vertically or horizontally without
distance between neighbouring units.
E.30
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
Mechanical specifications
Dimensions (HxWxD).....................................
Dimensions (HxWxD) w/ 4501
/ 4511.............................................................
Weight approx................................................
Weight incl. 4501 / 4511 (approx.).................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
Vibration.........................................................
Vibration: 2...13.2 Hz.....................................
Vibration: 13.2...100 Hz.................................
Common specifications
Supply voltage...............................................
Fuse...............................................................
Max. power consumption...............................
Max. internal power dissipation......................
Isolation voltage, test /working:
Input to any....................................................
-20°C to +60°C
-20°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
109 x 23.5 x 104 mm
109 x 23.5 x 116 / 131 mm
250 g
265 g / 350 g
DIN EN 60715/35 mm
0.13...2.08 mm2 AWG 26...14
stranded wire
0.5 Nm
IEC 60068-2-6 : 2007
±1 mm
±0.7 g
Output specifications
Current output: Signal range.........................
Load (max.)....................................................
Load stability, current output..........................
Current limit....................................................
Status relay output terminal
33-34: Relay function.....................................
Programmable low setpoint...........................
Programmable high setpoint..........................
Hysteresis for setpoints..................................
Max. voltage, status relay..............................
Max. current, status relay...............................
Max. voltage - hazardous installation.............
Max. current - hazardous installation.............
*of span..........................................................
3.5...23 mA
20 mA/725 Ω/14.5 VDC
≤0.01% of span / 100 Ω
≤ 28 mA
N.C.
0...29.9 mA
0...29.9 mA
0.1 mA
110 VDC / 125 VAC
0.3 ADC / 0.5 AAC
32 VDC / 32 VAC
1 ADC / 0.5 AAC
= normal measurement range
4...20 mA
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
UL................................................................... UL 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
SIL.................................................................. SIL 2 certified & fully assessed
acc. to IEC 61508
19.2...31.2 VDC
1.25 A SB / 250 VAC
≤ 2 W (2 channels)
≤ 2 W (2 channels)
E
2.6 kVAC / 300 VAC
reinforced isolation
Analog output to supply................................. 2.6 kVAC / 300 VAC
reinforced isolation
Status relay to supply..................................... 1.5 kVAC / 150 VAC
reinforced isolation
HART bi-directional communication
frequency range............................................. 0.5...7.5 kHz
Signal / noise ratio......................................... > 60 dB
Response time (0...90%, 100...10%)............. < 5 ms
Accuracy........................................................ Better than 0.1% of selected
range
mA, absolute accuracy................................... ≤ ±16 μA
mA, temperature coefficient........................... ≤ ±1.6 μA / °C
Effect of supply voltage change
on output (nom. 24 VDC)............................... < ±10 μA
EMC immunity influence................................ < ±0.5% of span
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Current input: Measurement
range..............................................................
Sensor error detection: Loop
break 4...20 mA..............................................
Input voltage drop, supplied
unit.................................................................
Input voltage drop, non-supplied
unit.................................................................
3,5...23 mA
< 1 mA
< 2 V @ 23 mA
< 4 V @ 23 mA
9107A-030115
E.31
Pulse isolator
9202A
– Interface for NAMUR sensors and switches
– Extended self-diagnostics and detection of cable fault
– 1 or 2 channels
– Can be supplied separately or installed on power rail, PR type 9400
– SIL 2-certified via Full Assessment
Advanced features
• Configuration and monitoring by way of detachable display
front (PR 4511/4501).
• Selection of direct or inverted function for each channel via
PR 4511/4501.
• Advanced monitoring of internal communication and stored
data.
• Optional redundant supply via power rail and/ or separate
supply.
• SIL 2 functionality is optional and must be activated in a menu
point.
E
Connections
Application
• The device can be mounted in and receive signals from nonclassified area and zone 2.
• Pulse isolator for transmission of signals from NAMUR
sensors and mechanical switches.
• Monitoring of error events and cable breakage via the
individual status relay and/or a collective electronic signal via
the power rail.
• The 9202A has been designed, developed and certified for
use in SIL 2 applications according to the requirements of IEC
61508.
Technical characteristics
• 1 green and 2 yellow/red front LEDs indicate operation status
and malfunction.
• 2.6 kVAC galvanic isolation between input, output and supply.
Mounting
• The devices can be mounted vertically or horizontally without
distance between neighbouring units.
E.32
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
Mechanical specifications
Dimensions (HxWxD).....................................
Dimensions (HxWxD) w/ 4501
/ 4511.............................................................
Weight approx................................................
Weight incl. 4501 / 4511 (approx.).................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
Vibration.........................................................
Vibration: 2...13.2 Hz.....................................
Vibration: 13.2...100 Hz.................................
Common specifications
Supply voltage...............................................
Fuse...............................................................
Max. power consumption...............................
Isolation voltage, test /working:
Input to any....................................................
Analog output to supply.................................
Output 1 to output 2.......................................
Status relay to supply.....................................
Communications interface.............................
-20°C to +60°C
-20°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
109 x 23.5 x 104 mm
109 x 23.5 x 116 / 131 mm
170 g
185 g / 270 g
DIN EN 60715/35 mm
0.13...2.08 mm2 AWG 26...14
stranded wire
0.5 Nm
IEC 60068-2-6 : 2007
±1 mm
±0.7 g
Output specifications
Relay output: Max. switching
frequency.......................................................
Max. voltage...................................................
Max. current...................................................
Max. AC power..............................................
Max. voltage, status relay..............................
Max. current, status relay...............................
Max. AC power, status relay..........................
Opto, NPN outputs: Max. switching
frequency.......................................................
Min. pulse length, NPN output.......................
Max. load, current / voltage............................
Voltage drop at 80 mA...................................
20 Hz
250 VAC / 30 VDC
2 AAC / 2 ADC
500 VA / 60 W
110 VDC / 125 VAC
0.3 ADC / 0.5 AAC
62.5 VA / 32 W
5 kHz
> 0.1 ms
80 mA / 30 VDC
< 2.5 VDC
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
UL................................................................... UL 61010-1
EAC TR-CU 020/2011................................... EN 61326-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
SIL.................................................................. SIL 2 certified & fully assessed
acc. to IEC 61508
19.2...31.2 VDC
400 mA SB / 250 VAC
≤ 3 W (2 channels)
E
2.6 kVAC / 300 VAC
reinforced isolation
2.6 kVAC / 300 VAC
reinforced isolation
1.5 kVAC / 150 VAC
reinforced isolation
1.5 kVAC / 150 VAC
reinforced isolation
Communication enabler 4511
/ Programming front 4501
< 200 ms
Response time for cable fault........................
Auxiliary supplies: NAMUR
supply............................................................. 8 VDC / 8 mA
Input specifications
Sensor types.................................................. NAMUR according to EN
60947-5-6 / mechanical
contact
Frequency range............................................ 0...5 kHz
Min. pulse length............................................ > 0.1 ms
Input resistance.............................................. Nom. 1 kΩ
Trig level, signal............................................. < 1.2 mA, > 2.1 mA
Trig level, cable fault...................................... < 0.1 mA, > 6.5 mA
9202A-030115
E.33
Solenoid / alarm driver
9203A
– Universal driver for solenoids, acoustic alarms and LEDs
– Extended self-diagnostics
– 1 or 2 channels
– Can be supplied separately or installed on power rail, PR 9400
– SIL 2-certified via Full Assessment
Advanced features
• Universal driver for the control of solenoids etc.
• Two hardware versions make it possible to choose either Low
(35 mA) or High (60 mA) current output.
• Configuration and monitoring by way of detachable display
front (PR 4511/4501).
• Selection of direct or inverted function for each channel via
PR 4511/4501 and the possibility of reducing the output
current to suit the application.
• Optional monitoring of the output current by way of PR
4511/4501.
• Optional redundant supply via power rail and/or separate
supply.
E
Connections
Application
• The device can be mounted in and transmit signals to nonclassified area and zone 2.
• Control of ON / OFF solenoids, acoustic alarms and LEDs.
• The 9203A is controlled by an NPN/PNP signal or a switch
signal.
• Monitoring of internal error events via the individual status
relay and/or a collective electronic signal via the power rail.
• The 9203A has been designed, developed and certified for
use in SIL 2 applications according to the requirements of IEC
61508.
Technical characteristics
• 1 green and 2 yellow/red front LEDs indicate operation status
and malfunction.
• 2.6 kVAC galvanic isolation between input, output and supply.
Mounting
• The devices can be mounted vertically or horizontally without
distance between neighbouring units.
E.34
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Storage temperature......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
Installation in..................................................
Mechanical specifications
Dimensions (HxWxD).....................................
Dimensions (HxWxD) w/ 4501
/ 4511.............................................................
Weight approx................................................
Weight incl. 4501 / 4511 (approx.).................
DIN rail type...................................................
Wire size........................................................
Screw terminal torque....................................
Vibration.........................................................
Vibration: 2...13.2 Hz.....................................
Vibration: 13.2...100 Hz.................................
Common specifications
Supply voltage...............................................
Fuse...............................................................
Max. power consumption...............................
Isolation voltage, test /working:
Input to any....................................................
Output 1 to output 2.......................................
Status relay to supply.....................................
Communications interface.............................
-20°C to +60°C
-20°C to +85°C
20...28°C
< 95% RH (non-cond.)
IP20
Pollution degree 2 &
measurement / overvoltage
cat. II
109 x 23.5 x 104 mm
109 x 23.5 x 116 / 131 mm
170 g
185 g / 270 g
DIN EN 60715/35 mm
0.13...2.08 mm2 AWG 26...14
stranded wire
0.5 Nm
IEC 60068-2-6 : 2007
±1 mm
±0.7 g
Output specifications
Output ripple................................................... < 40 mVRMS
Max. voltage, status relay.............................. 110 VDC / 125 VAC
Max. current, status relay............................... 0.3 ADC / 0.5 AAC
Max. AC power, status relay.......................... 62.5 VA / 32 W
Approvals
EMC............................................................... EN 61326-1
LVD 2006/95/EC............................................ EN 61010-1
UL................................................................... UL 61010-1
DNV Marine.................................................... Stand. f. Certific. No. 2.4
SIL.................................................................. SIL 2 certified & fully assessed
acc. to IEC 61508
19.2...31.2 VDC
1.25 A SB / 250 VAC
≤ 3.5 W (2 channels)
E
2.6 kVAC / 300 VAC
reinforced isolation
1.5 kVAC / 150 VAC
reinforced isolation
1.5 kVAC / 150 VAC
reinforced isolation
Communication enabler 4511
/ Programming front 4501
< ±0.5% of span
EMC immunity influence................................
Extended EMC immunity: NAMUR
NE 21, A criterion, burst................................. < ±1% of span
Input specifications
Trig level LOW, NPN+switch.......................... ≤ 2.0 VDC
Trig level HIGH, NPN+switch......................... ≥ 4.0 VDC
Max. external voltage, NPN+switch............... 28 VDC
Input impedance, NPN+switch....................... 3.5 kΩ
Trig level LOW, PNP...................................... ≤ 8.0 VDC
Trig level HIGH, PNP..................................... ≥ 10.0 VDC
Max. external voltage, PNP........................... 28 VDC
Input impedance, PNP................................... 3.5 kΩ
9203A-031315
E.35
Isolation amplifier
2204
– Input galvanically separated from output and supply
– Current or voltage input
– Signal conversion
– Current and voltage output
– 24 VDC supply or universally supplied
– Applicable in PELV/SELV circuits
Advanced features
• Factory-calibrated measurement ranges for input and outputs
in the 2204 can be selected by the internal DIP-switches
without the need for recalibration.
Connections
Application
• Signal isolator for analog current / voltage signals.
• 1 : 1 or signal conversion of analog current /voltage signals
within the ranges: 0...10 VDC or 0...50 mA on the input and
0...20 mA and 0...10 VDC in fixed ranges on the output.
• Analog signal conditioning with microprocessor based gain
and zero offset giving a response time of less than 25 ms.
E
Technical characteristics
• Universally supplied units have a 3-port galvanic separation
between input, supply, and output.
• Mounting for a standard 11-pole socket which can be adapted
for DIN rail or plate use with PR’s 7023 adaptor and 7024
mounting keying.
E.36
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP50
Mechanical specifications
Dimensions (HxWxD)..................................... 80.5 x 35.5 x 84.5 mm (D is
without pins)
Weight DC / universally supplied................... 110 g / 160 g
Common specifications
Supply voltage............................................... 19.2...28.8 VDC
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Internal consumption...................................... ≤ 1.3 W (2204--D )
Internal consumption...................................... ≤ 1.8 W (2204--P)
Isolation voltage, test /
working........................................................... 3.75 kVAC / 250 VAC
Accuracy........................................................ Better than 0.1% of selected
range
Signal / noise ratio......................................... Min. 60 dB
Response time (0...90%)............................... < 25 ms
Temperature coefficient................................. < ±0.01% of span / °C
Linearity error................................................. < 0.1% of span
Effect of supply voltage change..................... < ±0.002% of span / %V
EMC immunity influence................................ < ±0.5% of span
Output specifications
Max. offset...................................................... 20% of max. value
Current output: Signal range......................... 0...5 mA / 0...20 mA
Min. signal range............................................ 4 mA / 16 mA
Load (max.).................................................... 20 mA/600 Ω/12 VDC
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... 23...28 mA
*of span.......................................................... = of the presently selected
range
Approvals
EMC...............................................................
LVD 2006/95/EC............................................
PELV/SELV....................................................
EAC TR-CU 020/2011...................................
EN 61326-1
EN 61010-1
IEC 364-4-41 and EN 60742
EN 61326-1
E
Input specifications
Max. offset...................................................... 20% of max. value
Current input: Measurement
range.............................................................. 0...50 mADC
Min. measurement range (span),
current input................................................... 4 mA
Input resistance, current
input............................................................... Nom. 50 Ω
Voltage input: Measurement
range.............................................................. 0...10 VDC
Min. measurement range (span),
voltage input................................................... 0.2 VDC
Input resistance, voltage
input............................................................... 10 MΩ
2204-031915
E.37
AC / DC transmitter
2279
– Input galvanically separated from output and supply
– AC current measurement
– AC voltage measurement
– Current and voltage output
– 24 VDC supply or universally supplied
– Applicable in PELV/SELV circuits
Advanced features
• ±20% adjustment of the 0 and the 100% measurement range
is possible at the front panel.
• Input and output ranges are programmable by use of internal
DIP-switches.
Connections
Application
• AC current measurement e.g. in connection with a current
transformer or a current clamp.
• Direct AC voltage measurement.
E
Technical characteristics
• Analog signal conditioning with microprocessor based gain
and zero offset.
• Signals in the ranges 0.5...250 VRMS sinusoidal voltage can
be connected directly to the input, ranges are programmed
via DIP-switches and jumpers.
• Analog standard current output of 0/4...20 mA or standard
voltages of 0...1 or 0...10 VDC ranges are programmed via
DIP-switches and jumpers.
• Special currents and voltages within the signal range.
• Signal reversal e.g. 20...4 mA is possible in a special version.
• Universally supplied units have a 3-port galvanic separation
between input, supply, and output.
• Mounting for a standard 11-pole socket which can be adapted
for DIN rail or plate use with PR’s 7023 adaptor and 7024
mounting keying.
E.38
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP50
Mechanical specifications
Dimensions (HxWxD)..................................... 80.5 x 35.5 x 84.5 mm (D is
without pins)
Weight DC / universally supplied................... 100 g / 160 g
Common specifications
Supply voltage............................................... 19.2...28.8 VDC
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Max. power consumption............................... ≤ 1.3 W (2279--D)
Max. power consumption............................... ≤ 2.7 W (2279--P)
Isolation voltage, test /
working........................................................... 3.75 kVAC / 250 VAC
Signal / noise ratio......................................... Min. 60 dB
Response time (0...90%)............................... < 1.5 s
Effect of supply voltage change..................... < 0.005% of span / VDC
Temperature coefficient................................. < ±0.01% of span / °C
Linearity error................................................. < ±1% of span
EMC immunity influence................................ < ±0.5% of span
Output specifications
Max. offset...................................................... 20% of max. value
Current output: Signal range......................... 0...5 mA / 0...20 mA
Min. signal range............................................ 4 mA / 16 mA
Load (max.).................................................... 20 mA/600 Ω/12 VDC
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... 23...28 mA
Voltage output through internal
shunt.............................................................. See manual for details
*of span.......................................................... = of the presently selected
range
Approvals
EMC...............................................................
LVD 2006/95/EC............................................
PELV/SELV....................................................
EAC TR-CU 020/2011...................................
EN 61326-1
EN 61010-1
IEC 364-4-41 and EN 60742
EN 61326-1
E
Input specifications
Max. offset...................................................... 50% of max. value
Current input: Measurement
range.............................................................. 0...1 ARMS / 40...400 Hz
Min. measurement range (span),
current input................................................... 500 mARMS
Input resistance, current
input............................................................... Nom. 1 Ω
Voltage input: Measurement
range.............................................................. 0...250 VRMS / 40...400 Hz
Min. measurement range (span),
voltage input................................................... 0.5 VRMS
Input resistance, voltage
input............................................................... > 1 MΩ
2279-031915
E.39
Isolation amplifier
2284
– Galvanically separated input, output, and supply
– Bipolar current / voltage input
– Signal conversion
– Current and voltage output
– 24 VDC supply or universally supplied
– Applicable in PELV/SELV circuits
Advanced features
• Programmable input and output ranges using internal DIPswitches.
• Front panel fine adjustment of 0 and 100% values for special
ranges.
Connections
Application
• Galvanic separation of analog signals.
• Measurement of floating signals.
Technical characteristics
• Analog signal conditioning with microprocessor based gain
and zero offset with a fast response time of less than 25 ms.
• Signal conversion within the ranges: -250...+250 VDC or 50...+50 mA on the input and 0...10 (20) VDC and 0...20 mA
on the output.
• Galvanically separated between input, supply, and output.
• 2-wire transmitter supply and a reference voltage of 2.5 VDC,
max. 15 mA for short circuit-protected supply of
potentiometers.
• Buffered voltage output 0...20 V, 10 mA.
• The output can be ordered for standard 0/4...20 mA, and
0/1...5mA or special currents and selectable voltages within
the signal range 0...1 VDC or and ranges 0...10 VDC.
• Output signal reversal.
• Mounting for a standard 11-pole socket which can be adapted
for DIN rail or plate use with PR’s 7023 adaptor and 7024
mounting keying.
E
E.40
This page is automatically generated on the basis of information provided on www.prelectronics.com and affiliated websites. It is provided to you as a service and for information
purpose only. While we have attempted to maintain the information as accurately as possible, the page may contain errors or omissions for which we disclaim any and all liability
Environmental Conditions
Specifications range.......................................
Calibration temperature.................................
Relative humidity............................................
Protection degree...........................................
-20°C to +60°C
20...28°C
< 95% RH (non-cond.)
IP50
Mechanical specifications
Dimensions (HxWxD)..................................... 80.5 x 35.5 x 84.5 mm (D is
without pins)
Weight DC / universally supplied................... 125 g / 165 g
Common specifications
Supply voltage............................................... 19.2...31.2 VDC
Supply voltage, universal............................... 21.6...253 VAC, 50...60 Hz or
19.2...300 VDC
Max. power consumption............................... ≤ 2.4 W (2284--D)
Max. power consumption............................... ≤ 2.5 W (2284--P)
Isolation voltage, test /
working........................................................... 3.75 kVAC / 250 VAC
Signal / noise ratio......................................... Min. 60 dB
Response time (0...90%)............................... < 25 ms
Effect of supply voltage change..................... < 0.005% of span / VDC
2-wire transmitter supply
(pin 7...5)........................................................ 19...28 VDC / 20...0 mA
Auxiliary voltages: Reference
voltage............................................................ 2.5 VDC ±0.5% / 15 mA
Temperature coefficient................................. < ±0.01% of span / °C
Linearity error................................................. < 0.1% of span
EMC immunity influence................................ < ±0.5% of span
Output specifications
Max. offset...................................................... 20% of max. value
Current output: Signal range......................... 0...20 mA
Min. signal range............................................ 4 mA
Load (max.).................................................... 20 mA/1000 Ω/20 VDC
Load stability, current output.......................... ≤0.01% of span / 100 Ω
Current limit.................................................... 23...28 mA
Voltage output through internal
shunt.............................................................. See manual for details
Approvals
EMC...............................................................
LVD 2006/95/EC............................................
PELV/SELV....................................................
EAC TR-CU 020/2011...................................
EN 61326-1
EN 61010-1
IEC 364-4-41 and EN 60742
EN 61326-1
E
Input specifications
Max. offset...................................................... 50% of max. value
Current input: Measurement
range.............................................................. -50...+50 mADC
Min. measurement range (span),
current input................................................... 0.53 mADC
Input resistance, current
input............................................................... Nom. 50 Ω
Voltage input: Measurement
range.............................................................. -250...+250 VDC
Min. measurement range (span),
voltage input................................................... 27 mVDC
Input resistance, voltage
input............................................................... >1 MΩ...<10 MΩ
2284-031915
E.41
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF