ADTRAN 1xN User's Manual

Add to my manuals
12 Pages

advertisement

ADTRAN 1xN User's Manual | Manualzz

Section 61190860L1-5B

Issue 2, January 2002

CLEI Code: NCM5NTDD_ _

1xN Remote Protection Switch

Pro-Cap

Installation and Maintenance

CONTENTS

1.

GENERAL ................................................................ 1

2.

INSTALLATION ....................................................... 3

3.

CONFIGURATION ................................................... 4

4.

OPERATIONAL DESCRIPTION ............................. 5

5.

NORMAL OPERATION ........................................... 6

6.

PROTECT OPERATION ........................................... 6

7.

PROTECTION SWITCH ........................................... 8

8.

SWITCHBACK ........................................................ 10

9.

AUTO-PROTECT OPERATION ............................ 11

10. SPECIFICATIONS .................................................. 12

11. MAINTENANCE ..................................................... 12

12. WARRANTY AND CUSTOMER SERVICE ......... 12

FIGURES

Figure 1.

1xN Pro-Cap .................................................... 1

Figure 2.

SCIM Card Elements ...................................... 4

Figure 3.

Normal Operation ........................................... 6

Figure 4.

Arming Operation ........................................... 8

Figure 5.

Protect Operation .......................................... 10

Figure 6.

Switchover ..................................................... 10

Figure 7.

Total Access 3000 Auto-protect Switching .. 11

TABLES

Table 1.

LED Indication ................................................ 3

Table 2.

In-Band Commmands ..................................... 7

Table 3.

Out-Of-Band Commands ................................ 7

Table 4.

In-Band Enable/Disable Protocol ................... 8

Table 5.

In-Band Protection Switch Protocol ............... 9

Table 6.

Out-Of-Band Enable/Disable Protocol ........... 9

Table 7.

Out-Of-Band Protection Switch Protocol ....... 9

Table 8.

In-Band Protection Release Protocol ............ 11

Table 9.

Out-Of-Band Protection Release Protocol ... 11

Table 10.

Specifications ................................................ 12

1. GENERAL

This practice provides installation and operational procedures for the ADTRAN‚ Remote 1xN Pro-Cap protection switch multi-mount housing (P/N

1190860L1). See Figure 1. Pro-Cap initiates remote switching of a DS1 or HDSL circuit to a standby line following detection of a fault. This eliminates the immediate need for a vehicle dispatch to investigate trouble or provide standby service. The shelf also accommodates DDS and ISDN technologies but without protection.

Figure 1. 1xN Pro-Cap

Pro-Cap can be used in conjunction with the

ADTRAN Total Access ® 3000 Carrier Class

Broadband Multiservice Access

Platform, or any standard Office Repeater Bay (ORB) with T1 or HDSL to provide a Protection Switching

Network Interface (PSNI).

The Pro-Cap housing accepts eight T200 type circuit cards or four dual slot T400 DS-1, HDSL, or HDSL2 circuit cards. The unit is a wall mounted assembly that provides convenient access to CPE connections.

The assembly incorporates a circuit board backplane that provides a choice of amphenol connector or wire-wrap pins for facility wiring hook-up.

The Pro-Cap accepts -48 VDC local power or a modular power supply that inserts into the POWER slot at the far right of the shelf. The power supply module includes an AC power cord that plugs into a standard 110 VAC grounded outlet.

The Switch Customer Interface Module (SCIM) can mount to either the left or right side of the Pro-Cap housing to facilitate access to all CPE connections.

61190860L1-5B Section 61190860L1-5, Issue 2 trademarks, registered trademarks, or trade names of their respective holders.

1

The SCIM can be locally powered by -48 VDC, or span powered from the standby unit in slot 8 if equipped for span power. Slide switch S1 selects between local or span power. CPE receive and transmit connections are either amphenol or RJ-48C jacks.

Revision History

Issue 2 adds Auto-Protect information when the

Pro-Cap is configured in a Total Access 3000 network.

Features

The 1xN Pro-Cap includes these features:

• Protection module.

• Compact and lightweight assembly that accommodates eight T200 mechanics or four

T400 mechanics modules.

• Reversible SCIM for right side or left side assembly.

• Prewired backplane to minimize wiring errors and installation time.

• Protect module can function as standard channel module.

• Dedicated slot for modular power supply.

• LEC facility connections are made by 25-pair

Amphenol XMT/RCV connectors or wire-wrap pins.

• CPE connections are made to RJ-48C modular jacks or 25-pair Amphenol XMT/RCV connectors.

• Auto-Protect Switching with Total Access 3000 applications.

• Swing open tinted Plexiglas front cover.

• Available with key-locking metal cover (List 4

Option).

• Includes standard 10-year warranty.

Physical Description

The 1xN Pro-Cap consists of four elements:

1. Mounting-Plate

The mounting-plate attaches to a customer premises backboard.

2. Shelf

The shelf has slots for seven channel modules, one standby (protect) module, and one power module, plus two external edge connectors for the SCIM. The power terminal strip has connections for power, alarm, and ground. The shelf attaches to the mounting-plate.

3. Switch Customer Interface Module

This module inserts into one of the SCIM edge connectors located on either side of the shelf. It has both amphenol and RJ-48C interface connections to the customer loop. Behind an access panel is a power connection terminal strip, a slide switch for either span or local power, protect ON/OFF switch, and a pushbutton for selecting individual module protection or resetting the protect configuration.

Selection and status is indicated with associated

LEDs on the SCIM front panel.

4. Housing Cover

The Plexiglas swing door housing cover encloses the shelf allowing viewing and access to the shelf modules.

Functional Description

During normal customer and network transmission, data is transported through the active modules in slots 1 through 7. The module in slot 8 is the standby

(protect) unit. If a fault is detected on an active line a series of facility initiated manual commands switch the standby module to an active mode in place of the faulted unit. When the faulted unit malfunction is resolved another series of manually initiated commands (or the reset switch) returns it to active service and the standby unit is returned to standby status. The LED bank shows module status during normal and standby conditions. When circuit protection mode is disabled the Pro-Cap unit can be used as a standard 8-slot T200 mounting.

Auto-Protect Switching

When the Pro-Cap is used in association with the

ADTRAN Total Access 3000 platform, certain Total

Access 3000 cards initiate an automatic protect function with the Pro-Cap. These cards send the same protect enable/disable, arming, and switching codes as sent in the manual switching mode. The Pro-Cap does not require configuration changes to support the auto-protect feature. The same configuration supporting manual switching also supports automatic switching. Additional information is in Section 9 of this practice.

Listed here are Total Access 3000 cards that initiate the auto-protect codes:

• H2TUC 1181112L5

• H2TUR 1222026L7

• H2TUR 1221026L7

2 Section 61190860L1-5, Issue 2 61190860L1-5B

Documentation associated with the listed cards provides information on implementing the auto-protect function.

LED Indication

Table 1 describes LED indication.

• All LEDs OFF indicates no power to the SCIM.

• All LEDs flashing red indicates the protect card is disabled and SCIM power is local -48 VDC.

2. INSTALLATION

3. The shelf assembly lifts away from the mountingplate by disengaging the chassis tabs from the mounting-plate support hooks.

4. Using the mounting-plate as a template, position the mounting-plate at the desired location and mark four pilot holes. Ensure the unit is level and that cable plugs will reach their designated sockets.

5. Using an appropriate bit, drill the four pilot holes.

6. Align the mounting-plate to the pilot holes and attach to the wall with appropriate fasteners.

7. Reassemble the unit by reversing steps

1 through 3.

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

After unpacking the unit inspect it for damage. If damage is noted, file a claim with the carrier then notify ADTRAN. Refer to Warranty and Customer

Service.

Mounting Procedure

The 1xN Pro-Cap installs at the remote location using the following procedure:

Cable Connections

Frame Ground

Both the shelf and SCIM have separate ground connections. Each must be connected to a known approved ground location. Verify metal to metal contact on all connections and ensure ground circuit continuity.

NOTE

All component fasteners are spring-loaded, captured thumb screws.

The shelf has various openings for wire route options along with tie-wrap anchor points and extrusions for securing cables and connectors.

Specific wiring arrangements are customer developed.

1. Remove the housing from the shelf by unscrewing the two thumb screws on the side of the housing.

The housing pulls out and away from the shelf.

2. Remove the shelf from the mounting-plate by unscrewing the thumb screw at the top center of the shelf bay. It is not necessary to remove the

SCIM assembly unless its position is to be reversed to the other side of the shelf.

CAUTION

Transmit and receive loops to both facility and

CPE have two connection schemes. Only one connection method is to be used, not both.

Facility Side

Amphenol Connection – The to-facility and from-facility amphenols can be either left-side or right-side oriented.

Table 1. LED Indication

S

8 l o t

F

1

P R

A

-

L

I

7

E

L

D

O T

P

D e s

O F F r e o l t e e c c t t e d

N o N e t w o r k

S i g n a l

P r o t e c t

O p e r a t i o n a l

P

F l

R r o a

A e

P s c q r h t i u t e c t o

N v t

/

G e

E e a s

A t c t r n e t e t a b d e o n l e

S o

P l

P r o t e c t

E n a b l e d

S r i o d t e t a n

N /

G c t r d b

A e

I y e n n

P

P

P

F

D i

D r o

D l r o i i a s s s h r o t e c t s a b t e c t a b t e c t a b

*

* *

O n l

P r o y t e o n e c t s m o d w i t c u h l e

S 3 a t a t i

O F F .

m e i n s l o t s 1 t h r o u g h 7 c a n b e i n P r o t e c t M o d e .

R l e d e

C a d r d

* *

C a r d l e d * *

C a r d l e d * *

S o l i d R e d

I n P r o t e c t

M o d e *

N / A

P r o t e c t F a i l u r e

F l a s h R e d / G r e e n

N / A

P r o t e c t C a r d A r m e d

N / A

61190860L1-5B Section 61190860L1-5, Issue 2 3

Wire-Wrap – The to-facility and from-facility wire-wraps are an alternate method in lieu of the amphenol connections.

Customer Side

Amphenol Connection – The to-CPE and from-CPE amphenols should be left-side oriented to prevent

SCIM panel removal interference after amphenol installation.

RJ-48C – These modular jacks are an alternate method in lieu of the amphenol connections.

Shelf Cards

Channel cards are individually configured to meet network or customer requirements. Certain cards only receive power from network span power. These cards do not have pin contacts for shelf power.

CAUTION

It must be determined if channel cards can receive both span power and shelf power. Some cards may malfunction under that condition.

-48 VDC Terminal

Local DC power connects to terminal strip TB1 at the bottom of the shelf backplane. This power source is distributed across the backplane to slots 1 through 8 and can jumper to the SCIM TB1 to power the controller card.

SCIM Controller Card

Option switches on the SCIM controller circuit board are located behind an access panel. Remove the housing from the shelf to gain access to the panel’s thumb screw fastener (refer to Step 1 of the Mounting

Procedure). See Figure 2 for SCIM Card connections, terminals, indication, and switches.

NOTE

Both the shelf backplane and the SCIM card each have a TB1 terminal strip. This practice identifies the specific TB1 when referenced in the text.

3. CONFIGURATION

Shelf

There are no configuration selections on the shelf backplane. If -48 VDC is connected to TB1 on the shelf card there is no need for the power card unless for a spare power source.

Power Card

The PWR card has an AC power cord that inserts into a standard 110 volt AC grounded wall outlet. When

AC power is in use, local power should not be connected to TB1 on the shelf card. The PWR card also applies power to the same TB1 shelf terminals, which in turn can be jumpered to TB1 on the SCIM card.

Protect Card

The protect card can receive power from either the network (span) or from the backplane (-48 VDC). To initiate the protect feature the card in slot 8 must support the technology of the channel cards that are enabled for protection. The protect card should also have span power capability to power the SCIM should that configuration be used.

Figure 2. SCIM Card Elements

4 Section 61190860L1-5, Issue 2 61190860L1-5B

Span Power Switch S1

This switch selects between span power or local power.

SPAN – The SCIM receives power from the protect card in slot 8.

LOCAL – The SCIM receives power from local

-48 VDC to terminal strip TB1 on the

SCIM card.

OFF – The standby module in slot 8 is cut through and detection circuitry disabled. If the standby card was supplying span power to the SCIM, all the LEDs will be OFF. If the

SCIM was receiving local -48 VDC power, all the LEDs will flash red.

option.

NOTE

The protect card in slot 8 should have span power capability either permanent or as an enabled

NOTE

Local -48 VDC can be jumpered from the shelf

TB1 terminals.

Protection Select/Reset Switch S2

The first function of this pushbutton switch enables or disables standby protection for individual slots (1 through 7). Protection for selected slots can be disabled if cards of a different technology occupy those slots, or to meet SLA agreements. Protection is selected using the following procedure:

1. Depress S2 for 5 seconds. Slot 1 LED will start to flash green; all other LEDs will be OFF. Release

S2.

2. To enable protection for slot 1, press and release

S2. Slot 1 LED will turn solid green and the LED for slot 2 will begin to flash.

3. To pass over a slot that is not to be protect enabled, wait several seconds while that slot’s

LED is flashing. The LED turns OFF and the next

LED begins to flash green.

4. Continue this process until the LEDs for all slots designated for protection are ON.

The protect configuration, once established, is maintained in memory.

The second function of this switch is to reset the protect configuration in the event the protect card was enabled to temporarily replace a malfunctioning shelf card. After the system is returned to normal, depressing S2 for a minimum 5 seconds resets the protect configuration stored in memory. Immediately release the pushbutton when the LEDs return to the protect configuration.

Protect Switch S3

This switch controls the protect feature.

ON – All standby and protect functions are active.

Local Power

Terminal strip TB1 on the SCIM card accepts local -48

VDC power. Installation requires that wiring (14 to 26

AWG) be routed from the back of the SCIM housing.

This arrangement is an alternative to span power the

SCIM receives from the protect card. Slide switch S1 selects between span power or the -48 VDC supply.

SCIM frame ground is attained through a separate ground terminal.

4. OPERATIONAL DESCRIPTION

The SCIM card is a component of the Pro-Cap assembly that provides T1 drops to the customer through an RJ-48C or Amphenol connector. The T1

1x7 Controller Card is an enhanced SCIM that also performs manual 1x7 protection switching on T1

(HDSL) services. The controller card is designed to function as a manual protection switch and does not have the capability to address an automatic protection switch function.

T1 protection switching is accomplished through two network elements:

• Central Office Element (COE)

• Remote Element (RE).

The COE functions as the master of the protection switching operation by initiating all commands. The

RE will only respond to the COE commands. The controller card and a Network Interface Unit (NIU) represent the RE. A Digital Test Access Unit (DTAU), a Digital Cross-connect, or a T1 Test Set can represent the COE.

The controller card uses the card in slot 8 of the

Pro-Cap mounting as the standby service. The NIU in slot 8 will provide the appropriate physical layer interface to the network (i.e. HDSL2, HDSL, or T1

AMI) and 4-Wire T1 AMI physical layer interface to

61190860L1-5B Section 61190860L1-5, Issue 2 5

the controller card. The controller card will continuously monitor the network receive T1 transmission service in slot 8 (i.e. standby line) for commands. Upon the receipt of these commands, the controller card will initiate the T1 service switchover from the requested line (1 through 7) to the standby line. The controller card when optioned for protect will conduct the following:

1. Monitor the incoming network signal to determine if the protect line is operational. If the line is operational the FAIL LED will be OFF. If no signal is present, the slot 8 PROT LED will be

OFF and the FAIL LED will be ON.

2. Provide a loopback to the network as long as a transmit signal is not present from the CPE. If a signal is placed on the slot 8 CPE transmit to the network, the loopback will be released and normal transmission to and from the network can occur. Upon removal of the transmit signal, loopback will be activated.

The SCIM controller card can be locally or remotely provisioned to either enable or disable slot-switching capability. If a slot is protect enabled, when a switch request for that slot is received on the protect channel, the slot will switch. If the slot is protect disabled, it cannot be switched.

5. NORMAL OPERATION

Data is transported from the network to the customer through an assigned slot (slot 1 through slot 7). The standby line is transported through slot 8

(see Figure 3).

Normal Receive Path

The receive path is non-protected and transformer coupled between the network and the customer. The receive path is monitored for in-band or ESF bit-patterned datalink messages. The receive path toward the network will be terminated with a 100 ohm resistor. This 100 ohm termination increases the reliability of T1 signal recovery and minimizes crosstalk. The receive path toward the customer will be an open termination.

Normal Transmit Path

The transmit path is non-protected and transformer coupled between the network and the customer.

Passive Mode

The controller card can be configured to establish a passive transmission path by detecting a T1 signal from the customer. The transition from normal to passive mode will require the loopback to the network removed and the receive path to the customer to be reconnected.

Passive Mode to Normal Operation

The controller card will return to normal operation by detection of a loss-of-signal from the customer.

6. PROTECT OPERATION

Protect operation is defined as the transport of data from the network to the customer using a standby line connected to Slot 8. Communication between the COE and RE will be based upon in-band or out-of-band

(ESF datalink) commands. Upon detection of a fault on an active line, the controller card will not automatically switch the customer’s data onto the standby line. A remote provisioning command must be used to switch the customer’s data onto the standby line. Once the customer’s data is on the standby line,

DCS

CENTRAL OFFICE

DSX-1

Office

Repeater

Bay

< Live Traffic >

T1

Idle >

Office Repeater or

HTU-C

Office Repeater or

HTU-C

< Live Traffic >

T1 / HDSL / HDSL2

Idle >

CUSTOMER PREMISES

NIU

Main

DTWA

CIM

CPE

Standby

6

NORMAL OPERATION

Figure 3. Normal Operation

Section 61190860L1-5, Issue 2 61190860L1-5B

this condition will be locked until a remote provisioning command orders the controller card to switch the customer data back onto the main line, or a signal failure of greater than 30 seconds occurs on the protect Slot 8.

Protect Receive Path

The receive path is non-protected and transformer coupled between the network and the customer. The receive path is monitored for in-band or ESF bit-patterned datalink messages. The receive path will be a passive transmission path.

Protect Transmit Path

The transmit path is non-protected and transformer coupled between the network and the customer. The transmit path will be a passive transmission path.

In-Band Commands

The in-band commands are based on a 16-bit repeating binary pattern. These patterns were selected to avoid random data replication and yellow alarm generation.

In-band code qualifications involve receiving the codes for 5 contiguous seconds. The in-band codes can be transmitted using SF/ESF framing or unframed. See

Table 2 for in-band commands.

Out-of-Band Commands

The out-of-band commands are based on the ANSI

T1.403-1995 standard on T1 protection switching.

ANSI T1.403-1995, Table 4, specifies the command and response messages for T1 protection switching.

Out-of-band code qualifications involve receiving the codes for greater than 4 consecutive messages. See

Table 3 for out-of-band commands.

Table 2. In-Band Commands

C o m m a n d

H e x

P a t t e r n

B i n a r y P a t t e r n

S w i t c h A r m i n g C 4 4 0 1 1 0 0 0 1 0 0 0 1 0 0 0 0 0 0

S l o t E n a b l e C 5 4 0 1 1 0 0 0 1 0 1 0 1 0 0 0 0 0 0

C 6 4 0

C 4 4 F

1 1 0 0 0 1 1 0 0 1 0 0 0 0 0 0

1 1 0 0 0 1 0 0 0 1 0 0 1 1 1 1

S l o t D i s a b l e

S w i t c h R e l e a s e

S w i t c h A c t

C o d e i v a t i o n

L i n e 1

L i n e 2

L i n e 3

L i n e 4

L i n e 5

L i n e 6

L i n e 7

C 4 4 1

C 4 4 2

C 4 4 3

C 4 4 4

C 4 4 5

C 4 4 6

C 4 4 7

1 1 0 0 0 1 0 0 0 1 0 0 0 0 0 1

1 1 0 0 0 1 0 0 0 1 0 0 0 0 1 0

1 1 0 0 0 1 0 0 0 1 0 0 0 0 1 1

1 1 0 0 0 1 0 0 0 1 0 0 0 1 0 0

1 1 0 0 0 1 0 0 0 1 0 0 0 1 0 1

1 1 0 0 0 1 0 0 0 1 0 0 0 1 1 0

1 1 0 0 0 1 0 0 0 1 0 0 0 1 1 1

61190860L1-5B Section 61190860L1-5, Issue 2

Table 3. Out-Of-Band Commands

C o m m a n d

S w i t c h A r m i n g

H e x

P a t t e r n

1 8 F F

B i n a r y P a t t e r n

0 0 0 1 1 0 0 0 1 1 1 1 1 1 1 1

S l o t E n a b l e

S l o t D i s a b l e

S w i t c h R e l e a s e

S w i t c h A c t i v a t i o n

C o d e

R e s e t

L i n e 1

L i n e 2

L i n e 3

L i n e 4

L i n e 5

L i n e 6

L i n e 7

7 8 F F

7 A F F

2 6 F F

4 8 F F

4 A F F

4 C F F

4 E F F

2 4 F F

4 2 F F

4 4 F F

4 6 F F

0 1 1 1 1 0 0 0 1 1 1 1 1 1 1 1

0 1 1 1 1 0 1 0 1 1 1 1 1 1 1 1

0 0 1 0 0 1 1 0 1 1 1 1 1 1 1 1

0 0 1 0 0 1 0 0 1 1 1 1 1 1 1 1

0 1 0 0 0 0 1 0 1 1 1 1 1 1 1 1

0 1 0 0 0 1 0 0 1 1 1 1 1 1 1 1

0 1 0 0 0 1 1 0 1 1 1 1 1 1 1 1

0 1 0 0 1 0 0 0 1 1 1 1 1 1 1 1

0 1 0 0 1 0 1 0 1 1 1 1 1 1 1 1

0 1 0 0 1 1 0 0 1 1 1 1 1 1 1 1

0 1 0 0 1 1 1 0 1 1 1 1 1 1 1 1

7

7. PROTECTION SWITCH

Remote provisioning for a protection switch can be accomplished by sending a specific sequence of in-band or out-of-band messages. These remote provisioning commands are transmitted to the controller card from a remote test facility or a T1 test set at a DSX panel.

Arming

Arming the controller card prevents an inadvertent protection switch operation. The controller card can be armed with the presence of the appropriate in-band or out-of-band pattern on the network receive interface. Disarming the controller card can be accomplished with the presence of an in-band (11100) or out-of-band (ESF datalink) NIU loop down pattern on the network receive interface, a 1-hour time out, a protection switch, or a manual reset. See Figure 4 for arming activation.

In-Band Slot Enable/Disable Protocol

See Table 4 for in-band slot enable/disable protocol.

DCS

CENTRAL OFFICE

DSX-1

Office

Repeater

Bay

< Live Traffic >

T1

< Arming Code >

Office Repeater or

HTU-C

Office Repeater or

HTU-C

WECO D4

WESCOM 3192

TEST

< Live Traffic >

T1 / HDSL / HDSL2

< Arming Codes >

ARMING OPERATION

Figure 4. Arming Operation

CUSTOMER PREMISES

NIU

Main

DTWA

CIM

CPE

Standby

8

Table 4. In-Band Enable/Disable Protocol

S t e p

1

C o

C O E m m a n

I n B a n d d P a t t e r n s

S e n d A r m i n g C o d e C 4 4 0 H e x

I n B a n d P a t t e r n

2

3

S e n d S

D i s a b l e l o t

C o

E n d e a b l e o r C 5 4 0

C 6 4 0

H e x

H e x

E n a b l e

D i s a b l e

S e n d P

S w i t c h

= l i n e r o

C t e

4 4 c t

X i n u m b e r o n w

L h e i n r e e

X

C 4 4 X

X = L i

H e x n e N u m b e r

C o n t r o l l e r C a r d

L o o p b a c k t h e A r m i n g C o d e .

L o o p b a c k

N o S y n c f o t h e r 5

E n

S e a b l e c .

R

/ D i s e p e a a b t l u e n t c o d i l e f o r p a t t e r n

5 S e c , i s r e m o v e d .

t h e n

L o o p b a c k f o r 5 S p a t t e r n e c .

, i s t h e C 4 4 X t h e n N o r e m o v e d .

S c o d e y n c w f o r h

5 e r e

S

X e c .

=

R l i e p n e e a t n u m b e r u n t i l

4 R e m o v e P a t t e r n

S l o t i s n o s w i t c h i n g .

w E n a b l e d o r D i s a b l e d f o r p r o t e c t i o n

Section 61190860L1-5, Issue 2 61190860L1-5B

In-band Protection Switch Protocol

See Table 5 for in-band protection switch protocol.

Out-of-Band Enable/Disable Protocol

See Table 6 for out-of-band slot enable/disable protocol.

Out-of-Band Protection Switch Protocol

See Table 7 for out-of-band protection switch protocol.

Table 5. In-Band Protection Switch Protocol

S t e p

C o

C O E m m a n

I n B a n d d P a t t e r n s

1

2

I n B a n d

S e n d A r m i n g C o d e

S e n d P

S w i t c h r o

C t e c t i o n o d e

L i n e

S l o t E n a b l e d

S l o t D i s a b l e d

C 4 4 0 H e x

C 4

X

4

=

X

L i

H e x n e N u m b e r

P a t t e r n C o n t r o l l e r C a r d

L o o p b a c k t h e A r m i n g C o d e .

L o o p b a c k t h e C 4 4 X c o d e w h e r e X = l i n e n u m b e r .

P e r f o r m s w i t c h o v e r 5 s e c o n d s l a t e r .

L o s s o f s y n c .

C o n t i n

= l i n e u o u s n u m b

L o o p b e r .

N o a c k o f t h e s w i t c h o v e r

C 4 4 X a n d n c o o d e l o s s w h e r e o f s y n

X c .

Table 6. Out-Of-Band Enable/Disable Protocol

S t e p

C

C o m

O E m a n

I n B a n d d P a t t e r n s

1

B i t O r i e n t e d D a t a l i n k P a t t e r n

2

3

S e n d A r m i n g C o d e 0 0 0 1 1 0 0 0 1 1 1 1 1 1 1 1

S e n d S

D i s a b l e l o t

C

E o d n e a b l e o r

S e n d P

S w i t c h r o t e c t i o n L i n e

E n a b l e

D i s a b l e

0 1 1 1

0 1 1 1

1 0 0 0

1 0 1 0

1 1 1 1

1 1 1 1

1 1 1 1

1 1 1 1

(

0 1 0 0

X X X

X X X 0

= L i n e

1 1 1 1

N u m b

1 1 e r

1 1 s e e T a b l e 3 )

R e m o v e P a t t e r n

4

C o n t r o l l e r C a r d

L o o p b a c k A r m i n g C o d e f o r 4 0 0 m s f o l l o w e d b y A I S .

f

L o o p b a c k o l l o w e d t h e b y

E n

A I S .

a b l e / D i s a b l e c o d e f o r 4 0 0 m s

L o o p b a c k l i n e # c o d e f o r 4 0 0 m s f o l l o w e d b y A I S .

S l o t i s n o s w i t c h i n g .

w E n a b l e d o r D i s a b l e d f o r p r o t e c t i o n

Table 7. Out-Of-Band Protection Switch Protocol

S t e p

C O

C o m m

E a n

I n B a n d d P a t t e r n s

B i t O r i e n t e d D a t a l i n k P a t t e r n C o n t r o l l e r C a r d

1

2

S e n d A r m i n g C o d e 0 0 0 1 1 0 0 0 1 1 1 1 1 1 1 1

S e n

S w i t d c

P r o t e c t i o n h C o d e

L i n e 0 1 0 0

X X X

X X X 0

= L i n e

1 1 1 1

N u m

1 b

1 e r

1 1

( s e e T a b l e 3 )

S l o t E n a b l e d

L o o p b a c k A r m i n g C o d e f o r 4 0 0 m s f o l l o w e d b y A I S .

L o o p b a c k l i n e # c o d e :

S l o t D i s a b l e d

P e r f o r m r e c e i v e d .

s w i t c h o v e r a f t e r 4 c o n s e c t i v e m e s s a g e s

L o o p b a c k l i n e # c o d e f o l l o w e d b y A I S .

N o s w i t c h o v e r .

61190860L1-5B Section 61190860L1-5, Issue 2 9

See Figure 5 and Figure 6 for switchover codes and traffic results.

8. SWITCHBACK

Switchback operation is defined as the re-establishment of the T1 transmission path between the network and the customer using the regularly assigned line. Communication between the COE and

RE will be based upon in-band or out-of-band (ESF datalink) commands.

Switchback Receive Path

Remote

Switchback operation is accomplished by sending a specific sequence of SF in-band patterns or ESF datalink messages over the standby line.

NOTE

Communication using in-band codes will override the customer’s data during the switchback operation. The customer’s data will be overridden for 10 seconds. These remote provisioning commands are transmitted to the controller card from a remote test facility or a T1 test set at a DSX panel.

Local

Depressing S2 on the SCIM card for a minimum 5 seconds resets the protect configuration in memory.

10

CENTRAL OFFICE

DSX-1

Office

Repeater

Bay

< Live Traffic >

DCS

< Acknowledge

Switch Code >

Office Repeater or

HTU-C

Office Repeater or

HTU-C

WECO D4

WESCOM 3192

TEST

< Live Traffic >

T1 / HDSL / HDSL2

Switch Codes >

PROTECT OPERATION

Figure 5. Protect Operation

CUSTOMER PREMISES

NIU

Main

DTWA

CIM

CPE

Standby

DCS

CENTRAL OFFICE

DSX-1

Office

Repeater

Bay

< Live Traffic >

Office Repeater or

HTU-C

Office Repeater or

HTU-C

WECO D4

WESCOM 3192

TEST

T1 / HDSL / HDSL2

< Live Traffic >

SWITCHOVER

Figure 6. Switchover

Section 61190860L1-5, Issue 2

CUSTOMER PREMISES

NIU

Main

DTWA

CIM

CPE

Standby

61190860L1-5B

In-band Release Protocol

See Table 8 for return to normal operation.

Out-of-Band Release Protocol

See Table 9 for return to normal operation.

Signal Transmit

The controller card will transmit a 0 dB signal.

Line Build Out (LBO)

The controller card will not provide LBO functions.

The controller card will rely upon the NIU to provide

LBO.

9. AUTO-PROTECT OPERATION

When the Pro-Cap is configured in a Total Access

3000 network optioned for the auto-protect feature, the

TA 3000 will re-map a failed loop's data to the TA

3000 protect unit which in turn sends the protect initiate codes to the Pro-Cap. The Pro-Cap will put its protect unit online to complete the standby transmission loop to the customer. Loss of data transmission on a particular loop for any reason initiates the protect function. See Figure 7. Normal transmission is automatically restored when the failure is corrected.

Table 8. In-Band Protection Release Protocol

S t e p

1

C

C o m

O E m a n

I n B a n d d P a t t e r n s

S e n d s w i t c h r e l e a s e c o d e

I n B a n d P a t t e r n

C 4 4 F H e x

C o n t r o l l e r C a r d

L o o p b a c k R e l e a s e C o d e .

P e r f o r m s w i t c h b a c k 5 s e c o n d s l a t e r .

2 R e m o v e p a t t e r n S l o t i s r e t u r n e d t o n o r m a l o p e r a t i o n .

S t e p

Table 9. Out-Of-Band Protection Release Protocol

C o

C O E m m a n

I n B a n d d P a t t e r n s

B i t o r i e n t e d D a t a l i n k

P a t t e r n

C o n t r o l l e r C a r d

1 S e n d s w i t c h r e l e a s e c o d e 0 0 1 0 0 1 1 0 1 1 1 1 1 1 1 1 P e r f o r m s w i t c h b a c k a f t e r 4 c o n s e c u t i v e m e s s a g e s r e c e i v e d .

2 R e m o v e p a t t e r n S l o t i s r e t u r n e d t o n o r m a l o p e r a t i o n .

DS3

Feed

61190860L1-5B

L2

Total Access 3000

MUX

H2TU-Cs

4

3

2

1

D

C

B

A

Pro-Cap

Remote

Units

R4

R3

R2

R1

Normal Operation

Auto-Protect Operation (Loop A Failure)

Figure 7. Total Access 3000 Auto-protect Switching

Section 61190860L1-5, Issue 2

CPE

11

10. SPECIFICATIONS

See Table 10 for Specifications.

Table 10. Specifications

S p e c i f i c a t i o n

P h y s i c a l I n t e r f a c e :

S i g n a l :

C o d i n g :

F r a m i n g :

4

T

-

1

W i

A M I

S F , r e

B i p o

E S F , l a r o r B 8 Z S o r c o m p a t i b l e

U n f r a m e d

L i n e R a t e :

T r a n s m i t S i g n a l :

I n s e r t i o n L o s s :

L i n e I m p e d a n c e :

1 .

5 4

0

1

1

.

0 d

5

0

B d

4 o

B h

M b / s m m s a x

( ±

@ a t

2

5

7

0

7

0 %

2

) p p m k a t

H z

7 7 2 k H z

M a x i m u m

R a t e :

D e t e c t E r r o r

P o w e r :

< 1 0 3

D C V o l t a g e D r o p

P o w e r e d ) :

( S p a n

O p e r a t i n g

H u m i d i t y :

T e m p e r a t u r e :

U L

F C C

C o m p l i a n c e :

C o m p l i a n c e :

S p a n

L o c a l

P o w e r

P o w e r a t a t

5 7

± t o

2 4

5 6 V D C

6 3

V D m A

C t o

2 4 V D C a t 6 0 m A

4 0 °

U p t o

C t o +

9 5 %

6 5 n o

° n

C c o n d e n s i n g

U L

F C C

1 9 5 0

P a r t

3 r d

1 5 ,

E d i t i o n

S u b p a r t

A R e q u i r e m e n t s

B , C l a s s

11. MAINTENANCE

The Pro-Cap does not require maintenance for normal operation.

12. WARRANTY AND CUSTOMER SERVICE

ADTRAN will replace or repair this product within ten

(10) years from the date of shipment if it does not meet its published specifications or fails while in service.

Refer to ADTRAN U.S. and Canada Carrier Networks

Equipment Warranty, document 60000087-10.

Contact Customer And Product Service (CAPS) prior to returning equipment to ADTRAN.

For service, CAPS requests, or further information, contact one of the following numbers:

ADTRAN Sales

Pricing/Availability

(800) 827-0807

ADTRAN Technical Support

Pre-sales Applications/Post-sales Technical Assistance

(800) 726-8663

Standard hours: Monday-Friday, 7 a.m. - 7 p.m. CST

Emergency hours: 7 days/week, 24 hours/day

ADTRAN Repair/CAPS

Return for Repair/Upgrade

(256) 963-8722

Repair and Return Address

ADTRAN, Inc.

CAPS Department

901 Explorer Boulevard

Huntsville, Alabama 35806-2807

12 Section 61190860L1-5, Issue 2 61190860L1-5B