York Sunline 2000 BP180 Heat Pump Technical Guide
Below you will find brief information for Heat Pump Sunline 2000 BP180. This heat pump features dual refrigerant circuits for efficient part load operation, a unique ambient compensated time-temperature defrost system, and comes equipped with Simplicity Control Board for standardized functions such as fan delays, safety monitoring, nuisance trip protection, on-board diagnostics, and low ambient control. The unit can be installed on a roof, slab-mounted, or set on steel beams.
PDF
Download
Document
Advertisement
Advertisement
036-21537-001-A-0403 ® DESCRIPTION York Sunline 2000™ Heat Pumps are convertible single package units. All models have dual refrigerant circuits for efficient part load operation. Although the units are primarily designed for curb mounting on a roof, they can also be slab-mounted at ground level or set on steel beams above a finished roof. These heat pumps utilize a unique ambient compensated timetemperature defrost system. The defrost module automatically increases the time interval between defrost cycles as the outdoor ambient temperature decreases. This helps to eliminate unnecessary and costly defrosts. TECHNICAL GUIDE SUNLINE 2000TM SINGLE PACKAGE HEAT PUMPS MODEL BP180 15 NOMINAL TONS (WORLD 50 HZ) All units include: • • • • • • Simplicity Control Board Powder Paint finish that meets ASTM-B-117 750 hour salt spray standards Two-stage cooling provided by dual independent refrigeration circuits with expansion valves, filter-driers, high and low pressure/loss of charge switches and freezestats Hermetically sealed compressors with crankcase heaters • Permanently lubricated motors Bottom or side air discharge configuration capability (field convertible) Belt Drive Blower Motor • • Manufactured under the quality standards of ISO9001 Twenty-four volt control circuit with compressor lock-out • Zero-25% fixed air damper with hood • • Copper tube/aluminum fin coils Easy access to all components • • Rigging holes in base rails for lifting Single point power connection • • Complete factory package - tested, charged and wired Agency approvals on all units FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE 036-21537-001-A-0403 TABLE OF CONTENTS DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 PRODUCT NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . 3 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 FACTORY-INSTALLED OPTIONS . . . . . . . . . . . . . . . . . . . 9 FIELD-INSTALLED ACCESSORIES . . . . . . . . . . . . . . . . . 9 LIST OF FIGURES Fig. # LIST OF TABLES Tbl. # Pg. # 1 CAPACITY RATINGS - COOLING . . . . . . . . . . 11 2 CAPACITY RATINGS - HEATING . . . . . . . . . . . . . . 11 3 COOLING CAPACITIES (M3/S AIRFLOW) 180 UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 4 COOLING CAPACITIES (CFM AIRFLOW) 180 UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 5 HEATING CAPACITIES (M3/S AIRFLOW) 180 UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 6 HEATING CAPACITIES (CFM AIRFLOW) 180 UNIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Pg. # 1 SUNLINE 2000™ HEAT PUMP . . . . . . . . . . . . . . . . . 11 2 ELECTRONIC THERMOSTAT FIELD WIRING . . . . . 17 3 FIELD WIRING 24 VOLT THERMOSTAT . . . . . . . . . 17 4 FIELD WIRING DISCONNECT . . . . . . . . . . . . . . . . . . 18 5 UNIT DIMENSIONS - 15 TON . . . . . . . . . . . . . . . . . . 21 6 DETAIL “X” ACCY. SIDE SUPPLY & RETURN AIR OPENINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 7 BP180 SUPPLY AIR WITH DOWNFLOW DUCT APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 7 DETAIL “Y” UNIT WITH RAIN HOODS . . . . . . . . . . . 22 8 STATIC RESISTANCES . . . . . . . . . . . . . . . . . . . . . 16 8 CENTER OF GRAVITY . . . . . . . . . . . . . . . . . . . . . . . 22 9 POWER EXHAUST PERFORMANCE . . . . . . . . . . . 16 9 FOUR AND SIX POINT LOADS . . . . . . . . . . . . . . . . . 23 10 BLOWER MOTOR AND DRIVE DATA . . . . . . . . . . 16 10 ROOF CURB DIMENSIONS - 15 TON . . . . . . . . . . . . 23 11 VOLTAGE LIMITATIONS . . . . . . . . . . . . . . . . . . . . . 18 11 ROOF CURB BENEFITS . . . . . . . . . . . . . . . . . . . . . . 24 12 ELECTRICAL DATA -WITHOUT POWERED CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . 19 13 ELECTRICAL DATA -WITH POWERED CONVENIENCE OUTLET . . . . . . . . . . . . . . . . . . . . 19 14 TYPICAL ROOF-TOP INSTALLATION . . . . . . . . . . . 25 14 ELECTRIC HEAT CORRECTION FACTORS . . . . . 19 15 SIMPLICITY™ CONTROL WIRING DIAGRAM . . . . . 25 15 PHYSICAL DATA - BASIC UNIT . . . . . . . . . . . . . . . 20 16 OPERATING WEIGHTS (KG. / LBS.) . . . . . . . . . . . 20 17 MINIMUM CLEARANCES (MM/IN.) . . . . . . . . . . . . . 21 18 UTILITIES ENTRY DATA (MM/IN.) . . . . . . . . . . . . . . 21 19 FOUR AND SIX POINT LOADS . . . . . . . . . . . . . . . . 23 12 UNIT AND CURB APPLICATIONS . . . . . . . . . . . . . . . 24 13 TYPICAL APPLICATIONS . . . . . . . . . . . . . . . . . . . . . 24 2 Unitary Products Group 036-21537-001-A-0403 PRODUCT NOMENCLATURE 15T Sunline 2000™ Model Number Nomenclature York Brand B P 180 C 00 A 7 A AA 1 Product Category B = Heat Pump, Single Package Product Generation 1 = First Generation Product Identifier P = R-22 High Efficiency Heat Pump Voltage 7 = 380/415-3-50 Nominal Cooling Capacity - MBH 180 = 15 Ton Heat Type & Nominal Heat Capacity C00 = Cooling Only. No field installed electric heat Electric Heat Options E18 = 18 KW E36 = 36 KW E54 = 54 KW E72 = 72 KW Installation Options A = No Options Installed B = Option 1 C = Option 2 D = Options 1 & 2 E = Option 3 F = Options 4 G = Options 1 & 3 H = Options 1 & 4 J = Options 1, 2 & 3 K = Options 1, 2, & 4 L = Options 1,3 & 4 M = Options 1, 2, 3, & 4 N = Options 2 & 3 P = Options 2 & 4 Q = Options 2, 3, & 4 R = Options 3 & 4 S = Option 5 T = Options 1 & 5 U = Options 1, 3, & 5 V = Options 1, 4, & 5 W = Options 1, 3, 4, & 5 X = Options 3 & 5 Y = Options 4 & 5 Z = Options 3, 4, & 5 Options 1 = Disconnect 2 = Non-Pwr'd Conv Oultet 3 = Smoke Detector S.A. 4 = Smoke Detector R.A. 5 = Pwr'd Conv. Outlet Additional Options (See Next Page) Airflow A = Std Motor/Drive B = Std Mtr/Drive/Single Input Econo C = Std Mtr/Drive/Single Input Econo/Power Exhaust* D = Std Mtr/Drive/Motorized Damper F = Std Mtr/Drive/4" Filters G = Std Mtr/Drive/4" Filters/Single Input Econ H = Std Mtr/Drive/4" Filters/Single Input Econ/Power Exhaust* L = Std Mtr/Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters M = Std Mtr/Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters* N = Hi Static Drive P = Hi Static Drive/Single Input Econo Q = Hi Static Drive/Single Input Econo/Power Exhaust* R = Hi Static Drive/Motorized Damper T = Hi Static Drive/4" Filters U = Hi Static Drive/4" Filters/Single Input Econ V = Hi Static Drive/4" Filters/Single Input Econ/Power Exhaust* Y = Hi Static Drive/BAS Ready Econ (No BAS Controller) w/2" Pleated Filters Z = Hi Static Drive/BAS Ready Econ (No BAS Controller)/Power Exhaust w/2" Pleated Filters* Unitary Products Group 3 036-21537-001-A-0403 PRODUCT NOMENCLATURE - CONTINUED 15T Sunline 2000™ Model Number Nomenclature Additional Options AA None AB Phase Monitor AC Coil Guard AD Dirty Filter Switch AE Phase Monitor & Coil Guard AF Phase Monitor & Dirty Filter Switch AG Coil Guard & Dirty Filter Switch AH Phase Monitor, Coil Guard, & Dirty Filter Switch BA Hinged Filter Door & Tooless Access Panels BB Phase Monitor, Hinged Filter Door & Tooless Access Panels BC Coil Guard, Hinged Filter Door & Tooless Access Panels BD Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels BE Phase Monitor & Coil Guard, Hinged Filter Door & Tooless Access Panels BF Phase Monitor & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels BG Coil Guard & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels BH Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels CA CPC Controller with Dirty Filter Switch & Air Proving Switch CB CPC Controller, DFS, APS & Phase Monitor CC CPC Controller, DFS, APS & Coil Guard CD CPC Controller, DFS, APS, Phase Monitor, & Coil Guard CE CPC Controller, DFS, APS & Technicoat Cond. Coil CF CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor CG CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard CH CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard CJ CPC Controller, DFS, APS & Technicoat Evap. Coil CK CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor CL CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard CM CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard CN CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils CP CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor CQ CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard CR CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard DA CPC Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels DB CPC Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels DC CPC Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels DD CPC Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels DE CPC Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels DF CPC Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels DG CPC Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels DH CPC Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels DJ CPC Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels DK CPC Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels DL CPC Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels DM CPC Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels DN CPC Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels DP CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels DQ CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels DR CPC Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels 4 Unitary Products Group 036-21537-001-A-0403 Additional Options EA Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels EB Johnson UNT Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels EC Johnson UNT Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels ED Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels EE Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels EF Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels EG Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels EH Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels EJ Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels EK Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels EL Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels EM Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels EN Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels EP Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels EQ Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels ER Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels GA Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels GB Honeywell Excel 10 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels GC Honeywell Excel 10 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels GD Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels GE Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels GF Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels GG Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels GH Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels GJ Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels GK Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels GL Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels GM Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels GN Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels GP Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels GQ Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels GR Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels HA Honeywell Excel 10 Controller with Dirty Filter Switch & Air Proving Switch HB Honeywell Excel 10 Controller, DFS, APS & Phase Monitor HC Honeywell Excel 10 Controller, DFS, APS & Coil Guard HD Honeywell Excel 10 Controller, DFS, APS, Phase Monitor, & Coil Guard HE Honeywell Excel 10 Controller, DFS, APS & Technicoat Cond. Coil HF Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor HG Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard HH Honeywell Excel 10 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard HJ Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. Coil HK Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor HL Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard HM Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard HN Honeywell Excel 10 Controller, DFS, APS & Technicoat Evap. & Cond Coils HP Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor HQ Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard HR Honeywell Excel 10 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard JA Johnson UNT Controller with Dirty Filter Switch & Air Proving Switch Unitary Products Group 5 036-21537-001-A-0403 Additional Options JB Johnson UNT Controller, DFS, APS & Phase Monitor JC Johnson UNT Controller, DFS, APS & Coil Guard JD Johnson UNT Controller, DFS, APS, Phase Monitor, & Coil Guard JE Johnson UNT Controller, DFS, APS & Technicoat Cond. Coil JF Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor JG Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard JH Johnson UNT Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard JJ Johnson UNT Controller, DFS, APS & Technicoat Evap. Coil JK Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor JL Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard JM Johnson UNT Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard JN Johnson UNT Controller, DFS, APS & Technicoat Evap. & Cond Coils JP Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor JQ Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard JR Johnson UNT Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard NA Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch NB Novar ETC-3 Controller, DFS, APS & Phase Monitor NC Novar ETC-3 Controller, DFS, APS & Coil Guard ND Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard NE Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil NF Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor NG Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard NH Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard NJ Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil NK Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor NL Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard NM Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard NN Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils NP Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor NQ Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard NR Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard PA Novar ETC-3 Controller with Dirty Filter Switch & Air Proving Switch, Hinged Filter Door & Tooless Access Panels PB Novar ETC-3 Controller, DFS, APS & Phase Monitor, Hinged Filter Door & Tooless Access Panels PC Novar ETC-3 Controller, DFS, APS & Coil Guard, Hinged Filter Door & Tooless Access Panels PD Novar ETC-3 Controller, DFS, APS, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels PE Novar ETC-3 Controller, DFS, APS & Technicoat Cond. Coil, Hinged Filter Door & Tooless Access Panels PF Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels PG Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels PH Novar ETC-3 Controller, DFS, APS, Technicoat Cond. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels PJ Novar ETC-3 Controller, DFS, APS & Technicoat Evap. Coil, Hinged Filter Door & Tooless Access Panels PK Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Phase Monitor, Hinged Filter Door & Tooless Access Panels PL Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, & Coil Guard, Hinged Filter Door & Tooless Access Panels PM Novar ETC-3 Controller, DFS, APS, Technicoat Evap. Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels PN Novar ETC-3 Controller, DFS, APS & Technicoat Evap. & Cond Coils, Hinged Filter Door & Tooless Access Panels PP Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Phase Monitor, Hinged Filter Door & Tooless Access Panels PQ Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, & Coil Guard, Hinged Filter Door & Tooless Access Panels PR Novar ETC-3 Controller, DFS, APS, Technicoat Evap. & Cond Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels TA Technicoat Condenser Coil TB Technicoat Condenser Coil & Phase Monitor TC Technicoat Condenser Coil & Coil Guard TD Technicoat Condenser Coil & Dirty Filter Switch TE Technicoat Condenser Coil, Phase Monitor, & Coil Guard 6 Unitary Products Group 036-21537-001-A-0403 Additional Options TF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch TG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch TH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch TJ Technicoat Evaporator Coil TK Technicoat Evaporator Coil & Phase Monitor TL Technicoat Evaporator Coil & Coil Guard TM Technicoat Evaporator Coil & Dirty Filter Switch TN Technicoat Evaporator Coil, Phase Monitor, & Coil Guard TP Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch TQ Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch TR Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch TS Technicoat Evaporator & Condenser Coils TT Technicoat Evaporator & Condenser Coils & Phase Monitor TU Technicoat Evaporator & Condenser Coils & Coil Guard TV Technicoat Evaporator & Condenser Coils & Dirty Filter Switch TW Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard TX Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch TY Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch TZ Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch UA Technicoat Condenser Coil, Hinged Filter Door & Tooless Access Panels UB Technicoat Condenser Coil & Phase Monitor, Hinged Filter Door & Tooless Access Panels UC Technicoat Condenser Coil & Coil Guard, Hinged Filter Door & Tooless Access Panels UD Technicoat Condenser Coil & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UE Technicoat Condenser Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels UF Technicoat Condenser Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UG Technicoat Condenser Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UH Technicoat Condenser Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UJ Technicoat Evaporator Coil, Hinged Filter Door & Tooless Access Panels UK Technicoat Evaporator Coil & Phase Monitor, Hinged Filter Door & Tooless Access Panels UL Technicoat Evaporator Coil & Coil Guard, Hinged Filter Door & Tooless Access Panels UM Technicoat Evaporator Coil & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UN Technicoat Evaporator Coil, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels UP Technicoat Evaporator Coil, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UQ Technicoat Evaporator Coil, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UR Technicoat Evaporator Coil, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels US Technicoat Evaporator & Condenser Coils, Hinged Filter Door & Tooless Access Panels UT Technicoat Evaporator & Condenser Coils & Phase Monitor, Hinged Filter Door & Tooless Access Panels UU Technicoat Evaporator & Condenser Coils & Coil Guard, Hinged Filter Door & Tooless Access Panels UV Technicoat Evaporator & Condenser Coils & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UW Technicoat Evaporator & Condenser Coils, Phase Monitor, & Coil Guard, Hinged Filter Door & Tooless Access Panels UX Technicoat Evaporator & Condenser Coils, Phase Monitor, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UY Technicoat Evaporator & Condenser Coils, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels UZ Technicoat Evaporator & Condenser Coils, Phase Monitor, Coil Guard, & Dirty Filter Switch, Hinged Filter Door & Tooless Access Panels Unitary Products Group 7 036-21537-001-A-0403 FEATURES • Anti-Short Cycle Protection - To aid compressor life, an anti-short cycle delay is incorporated into the standard controls. Compressor reliability is further ensured by programmable minimum run times. For testing, the anti short cycle delay can be temporarily overridden with the push of a button. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. • Fan Delays - Fan on and fan off delays are fully programmable. Furthermore, the heating and cooling fan delay times are independent of one another. All units are programmed with default values based upon their configuration of cooling and heat. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with factory installed power exhaust are suitable for bottom duct connections only. For bottom duct, you remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, you replace the supply and return air panels on the rear of the unit with a side duct flange accessory. • Safety Monitoring - The control board monitors the high and low-pressure switches, the freezestats, the gas valve, if applicable, and the temperature limit switch on gas and electric heat units. The unit control board will alarm on ignition failures, compressor lockouts and repeated limit switch trips. • Nuisance Trip Protection and Strikes - To prevent nuisance trouble calls, the control board uses a “three times, you’re out” philosophy. The high and low-pressure switches and the freezestats must trip three times within two hours before the unit control board will lock out the associated compressor. • On Board Diagnostics - Each alarm will energize a trouble light on the thermostat, if so equipped, and flash an alarm code on the control board LED. Each high and low-pressure switch alarm as well as each freezestat alarm has its own flash code. The control board saves the five most recent alarms in memory, and these alarms can be reviewed at any time. Alarms and programmed values are retained through the loss of power. All models are available with a wide variety of factorymounted options such as phase monitor, dirty filter switch, and coil guard to make them suitable for almost every application. All models are available with these “factory mounted” outdoor air damper options: • Single enthalpy economizer • Single enthalpy economizer with power exhaust • Motorized outdoor air damper A fixed outdoor air intake assembly will be shipped in the return air compartment of all units ordered without an economizer or motorized outdoor air damper option. The assembly includes a rain hood with a damper that can be set for 10, 15 or 25% outdoor air. With bottom duct connections, the intake damper assembly should be mounted over the opening in the return air panel. With horizontal ductwork, it should be mounted on the return air duct. All supply air blowers are equipped with a belt drive that can be adjusted to meet the exact requirements of the job. A high static drive option is available for applications with a higher CFM and/or static pressure requirement. All units have long lasting powder paint cabinets with 750 hour salt spray test approval under ASTM-B117 procedures. All models are CSA approved. • All compressors have internal pressure relief. Every refrigerant circuit includes an expansion valve, a liquid line filterdrier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch to protect all system components. • Simplicity™ Controls - Simplicity™ control boards have standardized a number of features previously available only as options or by utilizing additional controls. • 8 Low Ambient - An integrated low-ambient control allows all units to operate in the cooling mode down to 0ºF outdoor ambient without additional assistance. Optionally, the control board can be programmed to lockout the compressors when the outdoor air temperature is low or when free cooling is available. Electric Heat Operation - All electric heat models (factory installed only) are wired for a single power source and include a bank of nickel chromium elements mounted at the discharge of the supply air blower to provide a high velocity and uniform distribution of air across the heating elements. Every element is fully protected against excessive current and temperature by fuses and two thermal limit switches. The power supply wiring can be routed into the control box through a threaded pipe connection in the base pan of the unit or through a knockout in the wiring panel on the front of the unit. • BAS Controls - York’s Sunline™ series units offer factory mounted BAS controls such as Novar, Honeywell, Johnson, and CPC. Unitary Products Group 036-21537-001-A-0403 FACTORY-INSTALLED OPTIONS • BAS - See “Additional Options” section in the product nomenclature. • • SMOKE DETECTORS - (supply air & return air) The smoke detectors stop operation of the unit by interrupting power to the control board if smoke is detected within the air compartment. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. • HIGH SPEED DRIVE - Includes a belt and blower pulley upgrade to enhance blower performance. • DIRTY FILTER SWITCH - This kit includes a differential pressure switch that energizes the fault light on the unit thermostat, indicating that there is an abnormally high pressure drop across the filters. Factory installed option or field installed accessory. • HINGED FILTER DOOR/”TOOLESS” BLOWER AND ACCESS PANELS (not hinged) - This option allows for easy access and maintenance. SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rainhood is painted to match the basic unit and must be field-assembled before installing. Power exhaust is not available as a field installed option. • POWER EXHAUST - Our single economizer options are available with power exhaust. Whenever the outdoor air intake dampers are opened for free cooling, the exhaust fan will be energized to prevent the conditioned space from being over-pressurized during economizer operation. The exhaust fan, motor and controls are installed and wired at the factory. The rain hood and the back-draft damper need to be assembled and installed in the field. NOTE: Knobs are shipped separately within the unit to prevent shipping damage. These must be field installed for tool-less operation. The power exhaust option can only be used on bottom duct configurations. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to a pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. FIELD-INSTALLED ACCESSORIES • The rain hood is painted to match the basic unit and must be field assembled before installing. • • • FILTER OPTIONS - Standard units are shipped with 2” throw-away filters installed. 2” pleated and 4” pleated filters are offered as a factory installed option. • CONVENIENCE OUTLET - This 110 volt outlet can be “powered” by the unit with a stepdown transformer or you may order the unit with a “non-powered” convenience outlet that can be wired in the field. • The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. PHENOLIC COATED EVAPORATOR AND CONDENSER COILS - Special coating process that utilizes Technicoat 10-1" processes. Coating is applied by total immersion of the complete coil for maximum protection. ELECTRIC HEATERS wired for single point power supply. These nickel chromium heater elements are provided with limit and automatic reset capability to prevent operation at excessive temperatures. DISCONNECT SWITCH - For heat pump units, a HACR breaker sized to the name plate max fuse size for the particular unit is provided. Factory installed option only. Unitary Products Group SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZERS - Includes a slide-in / plug-in damper assembly with fully modulating spring-return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The rainhood is painted to match the basic unit and must be field-assembled before installing. Power exhaust is not available as a field installed option. • MOTORIZED OUTDOOR AIR INTAKE DAMPER Includes a slide-in / plug-in damper assembly with a 2position, spring return motor actuator which opens to some pre-set position whenever the supply air blower is operating and will drive fully closed when the blower unit shuts down. The rain hood is painted to match the basic unit and must be field assembled before installing. Power exhaust is not available as a field installed option. • ROOF CURBS - Fourteen-inch high roof curbs provide a water-tight seal between the unit and the finished roof. 9 036-21537-001-A-0403 These full perimeter curbs meet the requirements of the National Roofing Contractors Association (NRCA) and are shipped knocked-down for field assembly. They're designed to fit inside the base rails of the unit and include both a wood nailing strip and duct hanger supports. • • 10 SIDE DUCT FLANGES - One-inch flanges replace the supply and return air panels on the rear of the unit to accommodate horizontal duct connections. These flanges can also be used individually for bottom supply/ horizontal return or horizontal supply/bottom return. They cannot be used on units with power exhaust. BAROMETRIC RELIEF DAMPER - This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. • HIGH SPEED DRIVE - A smaller blower pulley and a shorter belt increase the speed of the supply air blower for applications with a higher CFM and/or static pressure requirements. • ENTHALPY ACCESSORY CONTROL KIT - This kit contains the required components to convert a single enthalpy economizer to dual enthalpy. • BURGLAR BARS - Mount in the supply and return openings to prevent entry into the duct work. • WOOD SKID - Allows unit to be handled with 90” forks. • CO2 SENSOR - Senses CO2 levels and automatically overrides the economizer when levels rise above the present limits. • COIL GUARD - Customers can purchase a coil guard kit to protect the condenser coil from damage. This is not a hail guard kit. • PHASE MONITORS - Designed to prevent unit damage. The phase monitor will shut the unit down in an out-ofphase condition. Unitary Products Group 036-21537-001-A-0403 _ !#$ `j %+9%!%:+;<<> !?@!+@#!$ [ _ [ $ \ ]^ FIGURE 1 - SUNLINE 2000TM HEAT PUMP TABLE 1: CAPACITY RATINGS - COOLING DESIGN TEMPERATURES (°C) MODEL BP180 COP1 EER2 SENSIBLE OUTPUT kW / MBH LATENT OUTPUT kW / MBH 17.7 2.50 8.45 38.8 / 132 5.0 / 17 20.4 1.90 6.55 39.0 / 133 0.0 / 0 16.1 2.65 9.05 34.8 / 119 7.9 / 27 TOTAL OUTPUT TOTAL INPUT kW / MBH kW RATING3 POINT INDOOR DB / WB OUTDOOR DB / WB T1 27 / 19 35 / 24 43.8 / 149 T2 29 / 19 46 / 24 39.0 / 133 T3 21 / 15 27 / 19 42.7 / 146 1. COP = Coefficient of Performance - total output kW divided by the total input kW. 2. EER = Energy Efficiency Ratio - total output Mbh divided by the total input kW. 3. T1 = Moderate Climates, T2 = Hot Climates, T3 = Cool Climates. TABLE 2: CAPACITY RATINGS - HEATING DESIGN TEMPERATURES (°C) MODEL BP180 TOTAL OUTPUT kW / MBH TOTAL INPUT kW COP1 EER2 7/6 47.3 / 161 16.0 2.95 10.1 RATING POINT INDOOR DB / WB OUTDOOR DB / WB High 20 / 12 Low 20 / 12 2/1 27.4 / 93 14.5 1.90 6.45 X-Low 20 / 12 -7 / -8 19.8 / 68 13.3 1.50 5.10 ELECTRIC HEAT3 NOMINAL CAPACITY kW 15, 27, 40, 54 1. COP = Coefficient of Performance - total output kW divided by the total input kW. 2. EER = Energy Efficiency Ratio - total output Mbh divided by the total input kW. 3. Heaters available as factory-installed options - all with single point power supply. Unitary Products Group 11 036-21537-001-A-0403 TABLE 3: COOLING CAPACITIES (M3/S AIRFLOW) - 180 UNIT AIR ON INDOOR COIL m3/s WB °C TOTAL1 CAP. kW POWER2 INPUT KW SENSIBLE CAPACITY1, kW ENTERING DRY BULB TEMPERATURE, °C 32 30 28 26 24 22 @ 27°C AIR TEMPERATURE ON OUTDOOR COIL 3.40 2.83 2.12 23 60.8 16.3 51 44 38 32 25 - 21 57.4 16.1 57 51 44 38 32 25 19 54.0 15.8 54 54 51 45 38 32 17 52.2 15.7 52 52 52 49 43 36 15 50.5 15.5 50 50 50 47 41 35 23 59.0 16.2 44 39 33 27 22 - 21 55.7 16.0 50 44 39 33 28 22 19 52.4 15.7 52 50 44 39 33 28 17 50.7 15.6 51 51 48 42 37 31 15 48.9 15.4 49 49 49 46 41 35 23 54.2 15.8 37 33 28 24 20 - 21 51.1 15.6 42 38 33 29 25 20 19 48.1 15.4 47 43 38 34 30 25 17 46.5 15.2 47 46 42 37 33 29 15 45.0 15.0 45 45 45 40 36 32 @ 35°C AIR TEMPERATURE ON OUTDOOR COIL 3.40 2.83 2.12 23 58.7 21.0 45 38 32 26 19 - 21 54.4 19.1 53 46 40 34 27 21 19 50.2 17.3 50 50 48 41 35 29 17 49.5 18.5 50 50 50 43 37 31 15 48.8 19.7 49 49 49 45 39 32 23 54.7 17.9 41 35 30 24 19 - 21 50.7 16.3 48 43 37 32 26 20 19 46.8 14.7 47 47 45 39 33 28 17 46.1 15.8 46 46 46 41 35 30 15 45.5 16.8 45 45 45 42 37 31 23 51.6 20.6 32 28 24 19 15 - 21 47.9 18.7 38 34 30 25 21 17 19 44.1 16.9 44 40 35 31 27 22 17 43.5 18.1 44 41 37 32 28 24 15 42.9 19.3 43 42 38 34 29 25 @ 46°C AIR TEMPERATURE ON OUTDOOR COIL 3.40 2.83 2.12 23 50.2 20.3 44 38 31 25 19 - 21 47.3 19.8 47 44 38 31 25 19 19 44.4 19.3 44 44 44 38 32 25 17 43.4 19.3 43 43 43 40 34 27 15 42.3 19.2 42 42 42 39 33 26 23 48.1 20.1 39 34 28 22 17 - 21 45.3 19.6 45 39 34 28 23 17 19 42.5 19.1 43 43 39 34 28 23 17 41.5 19.0 42 42 41 36 30 24 15 40.5 18.9 41 41 41 37 32 26 23 44.8 19.5 32 28 23 19 15 - 21 42.3 19.0 37 32 28 24 19 15 19 39.7 18.6 40 37 33 29 24 20 17 38.7 18.5 39 39 34 30 26 21 15 37.8 18.4 38 38 36 32 27 23 1. These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the outdoor fan motors (Total 2.3 kW) and the compressor motors but not the supply air blower motor. 12 Unitary Products Group 036-21537-001-A-0403 TABLE 4: COOLING CAPACITIES (CFM AIRFLOW) - 180 UNIT AIR ON INDOOR COIL CFM WB °F TOTAL1 CAP. MBH POWER2 INPUT KW SENSIBLE CAPACITY1, MBH ENTERING DRY BULB TEMPERATURE, °F 90 86 82 79 75 72 @ 80°F AIR TEMPERATURE ON OUTDOOR COIL 7200 6000 4500 73 207 16.3 173 151 129 108 86 - 70 196 16.1 195 173 152 130 108 87 66 184 15.8 184 184 174 152 130 109 63 178 15.7 178 178 178 167 145 123 59 172 15.5 172 172 172 161 140 118 73 201 16.2 151 132 113 94 75 - 70 190 16.0 170 151 132 113 94 75 66 179 15.7 179 170 151 132 113 94 63 173 15.6 173 173 164 145 126 107 59 167 15.4 167 167 167 158 139 120 73 185 15.8 127 112 97 82 68 - 70 175 15.6 143 129 114 99 84 70 66 164 15.4 160 145 131 116 101 86 63 159 15.2 159 157 142 127 112 98 59 153 15.0 153 153 153 138 123 109 @ 95°F AIR TEMPERATURE ON OUTDOOR COIL 7200 6000 4500 73 200 21.0 153 131 109 88 66 - 70 186 19.1 179 158 136 114 93 71 66 171 17.3 171 171 163 141 120 98 63 169 18.5 169 169 169 147 126 104 59 167 19.7 167 167 167 154 132 110 73 187 17.9 140 121 102 83 64 - 70 173 16.3 165 146 127 108 89 70 66 160 14.7 160 160 152 133 114 95 63 157 15.8 157 157 157 139 120 101 59 155 16.8 155 155 155 145 126 107 73 176 20.6 110 96 81 66 51 - 70 163 18.7 130 115 101 86 71 56 66 151 16.9 150 135 121 106 91 76 63 148 18.1 148 140 125 110 96 81 59 146 19.3 146 145 130 115 100 86 73 171 20.3 150 129 107 85 64 - 70 161 19.8 161 151 129 107 86 64 66 152 19.3 152 152 151 129 108 86 63 148 19.3 148 148 148 136 114 93 59 144 19.2 144 144 144 134 112 90 73 164 20.1 133 114 95 76 57 - 70 155 19.6 153 134 115 96 77 58 66 145 19.1 145 145 134 115 96 77 63 142 19.0 142 142 140 121 102 83 59 138 18.9 138 138 138 127 108 89 73 153 19.5 109 94 80 65 50 - 70 144 19.0 125 111 96 81 66 52 66 135 18.6 135 127 112 98 83 68 63 132 18.5 132 132 117 103 88 73 59 129 18.4 129 129 123 108 93 78 @ 115°F AIR TEMPERATURE ON OUTDOOR COIL 7200 6000 4500 1. These capacities are gross ratings. For net capacity, deduct the heat of the supply air blower motor. Refer to the appropriate Blower Performance Table for the kW of the supply air blower motor. 2. These ratings include the outdoor fan motors (Total 2.3 kW) and the compressor motors but not the supply air blower motor. Unitary Products Group 13 036-21537-001-A-0403 TABLE 5: HEATING CAPACITIES1 (M3/S AIRFLOW) - 180 UNIT 3 m /s 2.12 2.83 3.40 CAP. RETUR (C) N AIR PWR. (P) ºC (KW) OUTDOOR AIR TEMPERATURE, ºC (72% RH) -20 -15 -10 -5 0 5 10 15 20 13 (C) (P) 13.3 8.8 17.1 9.4 21.8 10.1 27.4 10.8 33.8 11.5 41.0 12.3 49.2 13.2 58.2 14.1 68.1 15.1 20 (C) (P) 12.7 9.0 16.2 9.7 20.5 10.6 25.5 11.4 31.4 12.2 38.6 13.0 46.0 13.9 54.2 14.9 63.0 15.9 27 (C) (P) 12.1 9.2 15.3 9.9 19.1 10.7 23.8 11.5 29.1 12.3 35.1 13.2 41.8 14.1 49.2 15.1 57.1 16.1 13 (C) (P) 13.7 8.3 17.6 8.8 22.4 9.4 28.1 10.1 34.6 10.8 42.1 11.6 50.4 12.4 59.7 13.2 69.8 14.2 20 (C) (P) 13.2 8.9 16.9 9.6 21.5 10.3 26.9 11.0 33.3 11.8 41.1 12.7 49.3 13.6 58.3 14.6 68.2 15.6 27 (C) (P) 12.8 9.1 16.3 9.9 20.6 10.6 25.8 11.5 31.9 12.4 38.9 13.4 46.8 14.4 55.6 15.4 65.3 16.5 13 (C) (P) 14.0 7.8 18.0 8.3 22.9 8.9 28.8 9.5 35.5 10.1 43.2 10.9 51.8 11.6 61.2 12.4 71.6 13.3 20 (C) (P) 13.8 8.6 17.7 9.2 22.6 9.9 28.4 10.7 35.3 11.5 43.8 12.4 52.7 13.3 62.7 14.3 73.7 15.3 27 (C) (P) 13.5 9.0 17.3 9.8 22.1 10.6 28.0 11.5 35.0 12.5 43.1 13.5 52.4 14.6 62.9 15.8 74.6 17.0 1. The MBH and kW values do not include the supply air blower. TABLE 6: HEATING CAPACITIES1 (CFM AIRFLOW) - 180 UNIT CFM 4500 6000 7200 OUTDOOR AIR TEMPERATURE, ºF (72% RH) RETURN AIR ºF CAP. (MBH) PWR. (kW) -4 5 14 23 32 41 50 59 68 55 MBH kW 45 8.8 58 9.4 74 10.1 93 10.8 115 11.5 140 12.3 168 13.2 199 14.1 232 15.1 68 MBH kW 43 9.0 55 9.7 70 10.6 87 11.4 107 12.2 132 13.0 157 13.9 185 14.9 215 15.9 80 MBH kW 41 9.2 52 9.9 65 10.7 81 11.5 99 12.3 120 13.2 143 14.1 168 15.1 195 16.1 55 MBH kW 47 8.3 60 8.8 76 9.4 96 10.1 118 10.8 144 11.6 172 12.4 204 13.2 238 14.2 68 MBH kW 45 8.9 58 9.6 73 10.3 92 11.0 114 11.8 140 12.7 168 13.6 199 14.6 233 15.6 80 MBH kW 44 9.1 55 9.9 70 10.6 88 11.5 109 12.4 133 13.4 160 14.4 190 15.4 223 16.5 55 MBH kW 48 7.8 62 8.3 78 8.9 98 9.5 121 10.1 147 10.9 177 11.6 209 12.4 244 13.3 68 MBH kW 47 8.6 60 9.2 77 9.9 97 10.7 120 11.5 150 12.4 180 13.3 214 14.3 251 15.3 80 MBH kW 46 9.0 59 9.8 76 10.6 96 11.5 120 12.5 147 13.5 179 14.6 215 15.8 254 17.0 1. The MBH and kW values do not include the supply air blower. 14 Unitary Products Group 036-21537-001-A-0403 TABLE 7: BP180 SUPPLY AIR WITH DOWNFLOW DUCT APPLICATIONS AIRFLOW BLOWER SPEED, (RPM) MOTOR PULLEY (TURNS OPEN)* 2.10 m3/s 2.45 m3/s 2.80 m3/s 3.10 m3/s 3.40 m3/s ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) ESP (Pa) Output (kW) Input (kW) STANDARD DRIVE (m3/s) 845 6.0 173 1.8 2.2 138 2.2 2.6 83 2.6 3.1 18 3.0 3.5 - - - 885 5.0 208 1.9 2.3 172 2.3 2.8 115 2.7 3.3 49 3.1 3.7 - - - 925 4.0 245 2.0 2.4 208 2.4 2.9 149 2.9 3.4 82 3.3 3.9 - - - 960 3.0 281 2.1 2.6 242 2.6 3.1 182 3.0 3.6 114 3.4 4.1 30 3.8 4.6 1000 2.0 323 2.3 2.7 283 2.7 3.2 222 3.2 3.8 152 3.6 4.3 67 4.0 4.8 1040 1.0 369 2.4 2.9 327 2.9 3.4 264 3.3 4.0 193 3.8 4.5 107 4.2 5.1 357 2.4 2.8 316 2.8 3.4 253 3.3 3.9 183 3.7 4.5 97 4.2 5.0 HIGH SPEED DRIVE (m 1030 3/s) 6.0 1070 5.0 405 2.5 3.0 362 3.0 3.6 298 3.5 4.2 226 3.9 4.7 - - - 1115 4.0 461 2.7 3.2 416 3.2 3.8 351 3.7 4.4 278 4.2 5.0 - - - 1155 3.0 514 2.9 3.4 468 3.4 4.0 401 3.9 4.7 - - - - - - 1200 2.0 577 3.1 3.7 529 3.6 4.3 461 4.1 5.0 - - - - - - 1240 1.0 636 3.3 3.9 587 3.8 4.5 - - - - - - - - - BLOWER SPEED, (RPM) MOTOR PULLEY (TURNS OPEN)* AIRFLOW 4450 CFM 5190 CFM 5930 CFM 6565 CFM 7200 CFM ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) ESP (iwg) Output (bhp) Input (kW) STANDARD DRIVE (CFM) 845 6.0 0.7 2.4 2.2 0.6 2.9 2.6 0.3 3.5 3.1 0.1 4.0 3.5 - - - 885 5.0 0.8 2.6 2.3 0.7 3.1 2.8 0.5 3.7 3.3 0.2 4.2 3.7 - - - 925 4.0 1.0 2.7 2.4 0.8 3.3 2.9 0.6 3.8 3.4 0.3 4.4 3.9 - - - 960 3.0 1.1 2.9 2.6 1.0 3.4 3.1 0.7 4.0 3.6 0.5 4.6 4.1 0.1 5.2 4.6 1000 2.0 1.3 3.0 2.7 1.1 3.6 3.2 0.9 4.2 3.8 0.6 4.8 4.3 0.3 5.4 4.8 1040 1.0 1.5 3.2 2.9 1.3 3.8 3.4 1.1 4.5 4.0 0.8 5.1 4.5 0.4 5.7 5.1 HIGH SPEED DRIVE (CFM) 1030 6.0 1.4 3.2 2.8 1.3 3.8 3.4 1.0 4.4 3.9 0.7 5.0 4.5 0.4 5.6 5.0 1070 5.0 1.6 3.4 3.0 1.5 4..0 3.6 1.2 4.7 4.2 0.9 5.3 4.7 - - - 1115 4.0 1.9 3.6 3.2 1.7 4.3 3.8 1.4 5.0 4.4 1.1 5.6 5.0 - - - 1155 3.0 2.1 3.9 3.4 1.9 4.5 4.0 1.6 5.2 4.7 - - - - - - 1200 2.0 2.3 4.1 3.7 2.1 4.8 4.3 1.8 5.5 5.0 - - - - - - 1240 1.0 2.6 4.4 3.9 2.4 5.1 4.5 - - - - - - - - - NOTES: 1.Blower performance includes fixed outdoor air, 2” T/A filters, a dry evaporator coil and no electric heat. 2.Refer to Table 8 for additional static resistances. ESP = External Static Pressure available for the supply and return air duct system. All internal unit resistances have been deducted from the total static pressure of the blower. * Do NOT close the pulley below 1 turn open. ** Factory setting. Unitary Products Group 15 036-21537-001-A-0403 TABLE 8: STATIC RESISTANCES1 RESISTANCE, IWG/Pa m3/s (CFM) DESCRIPTION 15 TON 2.12 (4500) 2.83 (6000) 3.39 (7200) WET INDOOR COIL ELECTRIC HEAT OPTIONS 0.1/25 0.1/25 0.1/25 18 KW 0.1/25 0.1/25 0.1/25 36 KW 0.1/25 0.2/50 0.3/75 54 KW 0.2/50 0.3/75 0.4/100 72 KW 0.2/50 0.4/100 0.6/150 0.1/25 0.1/25 0.1/25 0.1/25 0.2/50 0.3/75 ECONOMIZER OPTION HORIZONTAL DUCT CONNECTIONS 2 1. Deduct these resistance values from the available external static pressures shown in the respective Blower Performance Table (See Note 2 for exception.) 2. Since the resistance to air flow will be less for horizontal duct connections than for bottom duct connections, add these pressures to the ESP values on the respective unit’s blower performance table. TABLE 9: POWER EXHAUST PERFORMANCE STATIC RESISTANCE OF RETURN DUCTWORK, IWG/Pa MOTOR SPEED 0.2/50 0.3/75 0.4/100 0.5/125 0.6/150 m3/s (CFM) KW m3/s (CFM) KW m3/s (CFM) KW m3/s (CFM) KW m3/s (CFM) KW HIGH* 2.47 (5250) 0.83 2.12 (4500) 0.85 1.98 (4200) 0.88 1.77 (3750) 0.93 1.41 (3000) 0.99 MEDIUM 2.31 (4900) 0.77 1.84 (3900) 0.79 1.65 (3500) 0.82 1.37 (2900) 0.85 - - LOW 2.07 (4400) 0.72 1.74 (3700) 0.74 1.41 (3000) 0.78 - - - - * Factory Setting Power Exhaust motor is a 3/4 HP, PSC type with sleeve bearings, a 48 frame and inherent protection. TABLE 10: BLOWER MOTOR AND DRIVE DATA UNIT SIZE (MBH) ADJUSTABLE MOTOR PULLEY2 FIXED BLOWER PULLEY kW/HP FRAME SIZE 845 - 1040 3.0/4.0 184T 83 109 - 135 / 4.3 - 5.3 29 / 1-1/8 1VP56 188 / 7.4 HIGH SPEED 1030 - 1240 3.7/5.0 DRIVE 184T 84 124-150 4.9-5.9 29 / 1-1/8 1VP62 175 / 6.9 STD DRIVE 180 MOTOR1 BLOWER RANGE (RPM) EFF. PITCH DIA. BORE (%) (mm / in.) (mm / in.) BELT (NOTCHED) DESIGNATION PITCH LENGTH (mm/in.) DESIGNATION QTY. 25 / 1 BK80 1773 / 69.8 BX68 1 25 / 1 BK75 1773 / 69.8 BX68 1 DESIG- PITCH DIA. BORE NATION (mm / in.) (mm / in.) 1. All motors are 1450 RPM, have sold bases and a 1.10 service factor. 2. Do NOT close this pulley below 1 turn open. 16 Unitary Products Group 036-21537-001-A-0403 U N IT T E R M IN A L S S T R IP T B 1 T H E R M O S T A T * T E R M IN A L S R C W R H W Y 1 2 Y 1 Y 2 1 O C C R E M O T E M IN P O S 2 G C Y 2 X 1 X X 3 R X 4 A 1 A 2 The thermostat must provide a “G” signal when there is a call for “W1.”The unit control board will energize the indoor blower when the compressors are energized; however, if the thermostat calls for “W2” during the antishort-cycle delay, the electric heat (when installed) will be energized immediately upon the call for “W2.” G W W 1 S D C T 2 4 V o lt T r a n s fo r m e r T T O R E M O T E S E N S O R 2 E T 0 4 7 0 1 3 2 4 IF U S E D * E le c tr o n ic p r o g r a m m a b le T h e r m o s ta t 2 E T 0 7 7 0 0 1 0 0 2 4 ( in c lu d e s s u b b a s e ) . T e r m in a ls A 1 a n d A 2 p r o v id e a r e la y o u tp u t to c lo s e th e o u td o o r e c o n o m iz e r d a m p e r s w h e n th e th e r m o s ta t s w itc h e s to th e s e t- b a c k p o s itio n . FIGURE 2 - ELECTRONIC THERMOSTAT FIELD WIRING NOTE: This unit does NOT REQUIRE a heat pump thermostat. It is designed to work with a standard two-stage cool, two-stage heat thermostat; however, the thermostat must provide a “G” signal when there is a call for “W1”. T -S T A T W 1 W 1 W 2 W 2 Y 1 Y 1 G G Y 2 O C C R E M O T E M IN P O S C R H U N IT C O N T R O L B O A R D Y 2 R C X The thermostat must provide a “G” signal when there is a call for “W1.”The unit control board will energize the indoor blower when the compressors are energized; however, if the thermostat calls for “W2” during the antishort-cycle delay, the electric heat (when installed) will be energized immediately upon the call for “W2.” R S D C FIGURE 3 - FIELD WIRING 24 VOLT THERMOSTAT Unitary Products Group 17 036-21537-001-A-0403 T E R M IN A L B L O C K T B 1 F A C T O R Y O R F IE L D S U P P L IE D D IS C O N N E C T G R O U N D L U G T H R P H A P O W S U P FIGURE 4 - E E S E E R P L Y FIELD WIRING DISCONNECT TABLE 11: VOLTAGE LIMITATIONS POWER SUPPLY 380/415-3-50 Note 1: Note 2: 18 VOLTAGE MIN. MAX. 342 456 Maximum HACR breaker of the same amp size is acceptable. Only 18kW of the 36 or 54kW, or only 36kW of the 72kW electric heat can be simultaneously energized with the mechanical heating. The full heater kW operates only if both compressors are locked out. Unitary Products Group 036-21537-001-A-0403 TABLE 12: ELECTRICAL DATA -WITHOUT POWERED CONVENIENCE OUTLET COMPRESSORS MODEL VOLTAGE TONNAGE RLA EACH LRA EACH HEATER OPTION ID OD FAN CONV BLOWER MOTORS OUTLET 2 MOTOR FLA EACH AMPS MODEL KW STAGES AMPS FLA - 380 12.8 128 2.1 8.3 0.0 BP180 415 12.8 128 2.1 8.3 0.0 0.0 - - MAX. MIN. FUSE/ CIRCUIT 1 AMPACITY BRKR SIZE (AMPS) (AMPS) 41.3 50 E18 11.3 1 17.1 62.8 70 E36 22.6 2 34.3 62.8 60 E54 33.8 2 51.4 74.6 80 E72 45.1 2 68.6 96.0 100 - 0.0 - - 41.3 50 E18 13.5 1 18.7 64.8 70 E36 26.9 2 37.4 64.8 70 E54 40.4 2 56.2 80.6 90 E72 53.8 2 74.9 88.1 100 Note 1: Maximum HACR breaker of the same amp size is acceptable. Note 2: Only 18kW of the 36 or 54kW, or only 36kW of the 72kW electric heat can be simultaneously energized with the mechanical heating. The full heater kW operates only if both compressors are locked out. TABLE 13: ELECTRICAL DATA -WITH POWERED CONVENIENCE OUTLET COMPRESSORS MODEL VOLTAGE TONNAGE 380 RLA EACH 12.8 LRA EACH 128 HEATER OPTION ID CONV OD FAN BLOWER MOTORS OUTLET 2 MOTOR FLA EACH AMPS MODEL KW STAGES AMPS FLA 2.1 8.3 6.3 BP180 415 12.8 128 2.1 8.3 6.3 MAX. MIN. FUSE/ CIRCUIT 1 AMPACITY BRKR SIZE (AMPS) (AMPS) - 0.0 - - 47.6 60 E18 11.3 1 17.1 69.1 70 E36 22.6 2 34.3 69.1 70 E54 33.8 2 51.4 82.4 90 E72 45.1 2 68.6 103.9 110 - 0.0 - - 47.6 60 E18 13.5 1 18.7 71.1 80 E36 26.9 2 37.4 71.1 80 E54 40.4 2 56.2 88.5 90 E72 53.8 2 74.9 94.4 100 Note 1: Maximum HACR breaker of the same amp size is acceptable. Note 2: Only 18kW of the 36 or 54kW, or only 36kW of the 72kW electric heat can be simultaneously energized with the mechanical heating. The full heater kW operates only if both compressors are locked out. TABLE 14: ELECTRIC HEAT CORRECTION FACTORS NOMINAL VOLTAGE VOLTAGE KW CAP. MULTIPLIER 380 380 0.627 415 415 0.75 Unitary Products Group 19 036-21537-001-A-0403 TABLE 15: PHYSICAL DATA - BASIC UNIT MODEL SUPPLY AIR BLOWER BP180 CENTRIFUGAL BLOWER (Dia. x Wd. mm.) (Dia. x Wd. in.) FAN MOTOR (KW/HP) 3.0/4 ROWS DEEP 4 FINS PER INCH 13 INDOOR COIL FACE AREA (Sq. M./Sq. Ft.) OUTDOOR FAN (Two Per Unit) (Each) 762/30 FAN MOTOR (KW/HP) (Each) 0.8/1.25 NOM. M3/S/CFM TOTAL (Each) 3.06/6500 ROWS DEEP 3 FINS PER INCH 15 FACE AREA (Sq. M./Sq. Ft.) 3.35/36.0 7-1/2 TON SCROL 2 COMPRESSOR (Qty. Per Unit) CHARGE 1.45/15/5 PROPELLER DIA. (mm/in.) OUTDOOR COIL AIR FILTERS 381 x 381 15 x 15 QUANTITY PER UNIT (457 X 610 X 51 mm) / (18" X 24" X 2") 5 TOTAL FACE AREA (Sq. M./Sq. Ft.) 1.4/15.0 REFRIGERANT 22 SYSTEM NO. 1 (Kg./Lbs.) 10.2/22.5 SYSTEM NO. 2 (Kg./Lbs.) 10.2/22.5 TABLE 16: OPERATING WEIGHTS (KG. / LBS.) MODEL Basic Unit BP180 BP (Heat Pump) 862/1900 Economizer 73/160 Economizer with Power Exhaust 111/245 Motorized Damper 68/150 Options Electric Heater Accessories 20 18 KW 11/25 36 KW 14/30 54 KW 16/35 72 KW 18/40 Roof Curb 79175 Barometric Damper 20/45 Wood Skid 91/200 Unitary Products Group 036-21537-001-A-0403 All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. FIGURE 5 - UNIT DIMENSIONS - 15 TON TABLE 17: MINIMUM CLEARANCES (MM/IN.) LOCATION Front CLEARANCE 914 mm/36” Back 610 mm/24” (Less Economizer) 1245 mm/49” (With Economizer Left Side (Filter Access) 610 mm/24” (Less Economizer) 914 mm/36” (With Economizer) Right Side (Cond. Coil) 914 mm/36” 1 0 mm/0” Below Unit Above Unit2 1829 mm/72” With 914 mm/36” Maximum Horizontal Overhang (For Condenser Air Discharge) TABLE 18: UTILITIES ENTRY DATA (MM/IN.) HOLE A B OPENING SIZE (DIA.) 28.6 mm/1-1/8” KO 19.1 mm/3/4” NPS (Fem.) 92.1 mm/3-5/8” KO 76.2 mm/3” NPS (Fem.) USED FOR Control Wiring Power Wiring Front Bottom Front Bottom NOTE: All entry holes should be field sealed to prevent rain water entry into building. 1. Units (applicable in U.S.A. only) may be installed on combustible floors made from wood or class A, B or C roof covering material. 2. Units must be installed outdoors. Overhanging structures or shrubs should not obstruct outdoor air discharge outlet. NOTE: Units and ductwork are approved for zero clearance to combustible materials when equipped with electric heaters. Unitary Products Group 21 036-21537-001-A-0403 DUCT COVERS - Units are shipped with the bottom duct openings covered. An accessory flange kit is available for connecting side ducts. For bottom duct applications: 1. Remove the side panels from the supply and return air compartments to gain access to the bottom supply and return air duct covers. 2. Remove and discard the bottom duct covers. (Duct openings are closed with sheet metal covers except when the unit includes a power exhaust option. The covering consists of a heavy black paper composition.) 3. Replace the side supply and return air compartment panels. For side duct applications; 1. Replace the side panels on the supply and return air compartments with the accessory flange kit panels. 2. Connect ductwork to the duct flanges on the rear of the unit. OUTDOOR AIR PANEL SIZE 15 TON UNITS 21-1/2" X 43" FIGURE 6 - DETAIL “X” ACCY. SIDE SUPPLY & RETURN AIR OPENINGS FIGURE 7 - DETAIL “Y” UNIT WITH RAIN HOODS FIGURE 8 - CENTER OF GRAVITY 22 Unitary Products Group 036-21537-001-A-0403 B D C A A FRONT C FRONT B D 6 Point Loads 4 Point Loads FIGURE 9 - E F FOUR AND SIX POINT LOADS TABLE 19: FOUR AND SIX POINT LOADS 4 - POINT LOADS (Kg. / Lbs.) UNIT 180 TOTAL A B C D 952 / 2100 233 / 513 231 / 510 253 / 558 253 / 559 NOTE: These weights are with economizer and 72 kW electric heat. 6 - POINT LOADS (Kg. / Lbs.) UNIT 180 TOTAL A B C D E F 952 / 2100 155 / 342 162 / 358 161 / 357 164 / 372 161 / 356 155 / 341 NOTE: These weights are with economizer and 72 kW electric heat. FIGURE 10 - ROOF CURB DIMENSIONS - (180 & 240 UNITS) Unitary Products Group 23 036-21537-001-A-0403 FIGURE 11 - ROOF CURB BENEFITS FIGURE 12 - UNIT AND CURB APPLICATION FIGURE 13 - TYPICAL APPLICATIONS 24 Unitary Products Group 036-21537-001-A-0403 FIGURE 14 - TYPICAL ROOF-TOP INSTALLATION THERMOSTAT TERMINALS CONTROL TERMINAL BLOCK W1 W1 W2 1 W2 Y1 Y1 Y2 G 2 OCC P G P1 R Y2 Smoke Detector X C R 4 SD RC OCC X 5 C R 3 SD SD 6 Jumper C 24 VAC Class 2 TERMINALS ON A LIMITED NUMBER OF THERMOSTATS 1 Second stage heating not required on single stage heating units. 2 Second stage cooling not required on single stage cooling units. 3 Jumper is required if there is no Smoke Detector circuit. 4 Jumper is required for any combination of R, RC, or RH. 5 OCC is an output from the thermostat to indicate the Occupied condition. 6 X is an input to the thermostat to display Error Status conditions. FIGURE 15 - SIMPLICITY™ CONTROL WIRING DIAGRAM Unitary Products Group 25 036-21537-001-A-0403 26 Unitary Products Group 036-21537-001-A-0403 Unitary Products Group 27 Subject to change without notice. Printed in U.S.A. Copyright © by Unitary Products Group 2003. All rights reserved. Unitary Products Group 5005 York Drive 036-21537-001-A-0403 Supersedes: Nothing Norman OK 73069 ">

Public link updated
The public link to your chat has been updated.
Advertisement
Key features
- Dual refrigerant circuits
- Ambient compensated defrost
- Simplicity Control Board
- Roof, slab, or beam mountable
- Bottom or side air discharge
- High static drive option
- Factory-installed options
- CSA approved
Frequently asked questions
Dual refrigerant circuits allow for efficient part load operation, improving energy efficiency and reducing operating costs.
This system automatically increases the time interval between defrost cycles as the outdoor ambient temperature decreases, eliminating unnecessary and costly defrosts.
The Simplicity Control Board offers standardized features like fan delays, safety monitoring, nuisance trip protection, on-board diagnostics, and low ambient control, simplifying operation and maintenance.