Aiphone COMMUNICA TB-12F User's Manual

Aiphone COMMUNICA TB-12F User's Manual
 <> AIPHONE 532041 10-0080 x. COMMUNICA
TELEPHONE TYPE INTERCOM TB-F series
MODELS TB-1F (single-way) TB-3F (three-way)
TB-6F (six-way) TB-12F (twelve-way)
COMMON TALK SELECTIVE RING
— INSTRUCTIONS —
(1D)
NAMES AND FUNCTIONS
(1) Receiver cradle for wall mounting, included (7) Handset
(2) Station selector buttons Microphone
(3) Case (9) Coil cord
(4) Receiver Terminal cord
(5) Paging button aD Terminal box
(6) Directory card
SPECIFICATIONS
* Power source: DC 12 volt. Use PS-12A (PS-12C in North America) AC adaptor. If your system does not in-
clude door station or paging system, you may use PS-12S AC adaptor.
* Current consumption: 70 mA maximum per station.
* Calling: Push-button station selection. An electronic tone sounds when the selected station button is
depressed.
* Paging: Use PB-1 paging adaptor in conjunction with standard paging amplifier and speakers.
* Wiring: Up to 17 conductors may be required. Please refer to wiring diagram showing system that
meets your requirements.
BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT - Prohibitions and precautions —
* Operation; NEVER
1. DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET. THE CALL
TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE
HEARING DAMAGE,
* Installation;
1. DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.
2. Be sure to remove plug of power supply from AC outlet before you open the unit or make
wiring connections.
3. Avoid running the connecting wires thru doors, windows or between furniture, which may
pinch and disconnectect the wires.
4. The intercom equipment must be installed in as dry and dust-free environment as possible.
* Maintenance;
1. Clean your intercom equipment with a soft cloth dampened with neutral household cleanser.
Never use thinner nor benzine, etc.
2. Do not splash water on the door station by hose, etc.
— 1 —
FEATURES
ко # * %
Up to 13 stations can be connected in a system.
Common talk system for phone communication. (Conference calls can selectively include up to 6 stations)
Separate paging channel. Paging announcement may be done separately and independently from phone communication.
ECM (Electret condenser mic) provides excellent voice fidelity.
Phone designed for either desk use or wall mounting. Terminal cord may be pulled out from either the top or the bottom
of the phone.
OPTIONS
+
Door station IC-DC can be installed with adaptor DB-U. Up to two door stations may be connected to a maximum
of 12 phones.
One call sub station TB-A is available where paging or door station communication is not required (TB-A is designed for
wall mounting only).
* Phone system may be connected to existing paging and background music system using adaptor PB-1.
Talkback paging available through existing paging system using adaptor PB-2 in conjunction with PB-1.
A call in a noisy area may be annunciated by a separate buzzer or bell using the RY-AC relay.
EQUIPMENT AVAILABLE FOR USE WITH YOUR TB-F PHONE SYSTEM
SP-3: Paging speaker. Complete and ready
to install including round flush mounting
frame.
TB-1F: 1 call master station with paging
button (will not work with door station).
TB-3F: 3 call master station with paging
button and door station capability. NCH-2: Noise-resistant handset.
For field installation only.
TB-6F: 6 call master station with paging
button and door station capability.
TB-12F: 12 call master station with paging
button and door station capability,
TB-A: 1 call sub station without paging or
door station capability. Wall mounting only
(not avaialble in U.S.A.).
IC-DC: Surface mount standard door sation.
DB-U: Adaptor for door station. Requires
between one door station and TB-F phones.
PB-1: Paging adaptor. Connects all TB-F
phones to a paging system and background
music source.
PB-2: Paging adaptor with talkback. Must
be used in conjunction with PB-1.
PG-10A, PG-30A, PG-60A: UL & CSA
approved paging amplifier. 10W, 30W, 60W
(available only in North America).
PG-10B, PG-30B, PG-60B: Standard paging
‘ amplifier. 10W, 30W, 60W.
INSTALLATION
RY-SP: Local speaker cutout relay,
RY-AC: Relay for operating external device
such as additional calling buzzer or bell,
door release, etc.
EL-9S: Electric door release. Requires sepa-
rate transformer and RY-AC.
PS-12C: CSA & UL Listed power supply
(available only in North America).
PS-12A: Power supply. Standard every-
where except North America.
PS-12S: Power supply. May be used in a
TB-F system which does not include door
station or paging system (not available in
North America).
PG-3: 3-watt paging amplifier.
Do not attempt to install you intercom system until you have read and thoroughly understood the installation procedure.
Aiphone’s warranty is void if system is installed in a manner other than described in this manual.
Lay out your system in advance. Determine the exact location of each station. We recommend a full complement of wire
be installed, even though you may not initially be installing the maximum number of stations available to your system. This
way, should you decide to add a station later, you can avoid running additional cables to existing stations.
I
WIRING REQUIRED
TB-1F: 5 Conductors maximum
TB-3F: 8 Conductors maximum
TB-6F:
TB-12F:
11 Conductors maximum
17 Conductors maximum
Refer to the chart below and select the proper wire gauge to meet your requirements.
AWG WIRE SIZE 24 AWG _ 22 AWG 20 AWG
MAXIMUM COMMUNICATION DISTANCE , ,
BETWEEN MOST DISTANT PHONES 1200 2000 3000
MAXIMUM COMMUNICATION DISTANCE 300' 500° 700°
FROM PHONE TO DOORS STATION |
DIAMETER OF WIRE 0.5 mm | 0.65 mm 0.8 mm
MAXIMUM COMMUNICATION DISTANCE 400 650 1000
BETWEEN MOST DISTANT PHONES m m m
MAXIMUM COMMUNICATION DISTANCE 90 150 230
FROM PHONE TO DOOR STATION m m m
Begin your installation with station #1.
the position of the C terminal at each station. Be sure you wire each station correctly.
After installing your second station we recommend that the power supply be connected to the Sand O terminal lines at a
convenient location and that a test be made for calling and talking between each station. As each additional station is install-
ed re-test between each station. Unplug power supply while making wiring connections.
ACTUAL TB-F TERMINAL LOCATIONS
TB-1F
Height: 30 mm
(1-3/16”')
= 0 = =
— E] 2
= 3llızomm IE
_ — | (4-3/4) |
LP |
— Er —
— Y =®
a
1
TB-3F
(1D) -
© O:
ес >
но до
: for connecting relative stations
Lee 11|
+
®
|
y o
ol
in
©
©
€
for power supply
: for receiving call and talking
: for connecting door station
TB-6F
С
Sr co
ee —
Ps
E: <®
Ss E]
Be o
Г -®
LH {1
: for both door station and paging
INSTALLATION FOR WALL MOUNTING
1) Attach the mounting bracket to wall or
single gang plaster
ring.
2) Attach handset cradle included, as shown
in illustration.
NOTE: Terminal cord may be pulled out
from either the top or the bottom
of the body, or straight back to
plaster ring.
INSTALLATION OF TERMINAL BOX
(Can be mounted easily to wall or single gang
box.)
1) Remove screws and cover as shown.
2) Attach bottom case to wall or 1-gang box.
3) Replace cover after wiring.
TB-12F
©
= О =
BD nd
GE 120)
De o
es e
e | | e
$7
De +®)
a ©
HH, AH
105 mm
4-1/8")
A space is provided at the left of the diagram to write in your color code. Note
* Please refer to the labels
on the sides of terminal
box and back of the
cover.
TERMINAL
IDENTIFICATIONS
| x y 232 mm
- sm (9-1/8")
3 > e”
|
TB-12F ALL MASTE
STATION STATION STATION STATION STATION STATION STATIO
1 2 3 4 5
—
—
—
с
2 2
3 С
4 4
5 5
6 6
7 7
8 8
9 9
COIN Of NJ Qf Of |] WN
Ol Oop] WIN
MIMI MUOO JCOrFOO OZ-D-5 M-4-T5
+
e
TB-12F PHONE SYSTEM with PAGING
STATION STATION STATION STATION STATION STATION STATION
1 2 3 4 5 6 7
ml
© 00 <" со с в © oo
Wl] 0] Of Oo] OO] hj WEN
W
R
!
T
E
W
i
R
|
N
G
C
O
L
O
U
R
С
O
D
E
H
E
R
E
R PHONE SYSTEM
STATION STATION STATION STATION STATION STATION
8 9 10 11 12 13
—
—
—
mail
ach
ОР ОЕ О Во | А | о]
O1 O| OI SE O| сл А со | К
Ор со 1 DOI С] PH] WIN
ФЕ 0 | О | 1 |
© 00 1 3 | С) | ол | Е |
9
D DO
PO РО
| +
* Place PS-12A (or PS-12C)
= power supply near the
ter of the system.
and BACKGROUND MUSIC SYSTEM
PAGING SPEAKER
Г = —= == == =
t
!
JC
Laa
STATION STATION PB-1
8
STATION
10
STATION
11
STATION
12
STATION
9
—
NO-POLARIZED
PG-A or PG-B
PAGING AMP
OUTPUT
O WV] Nw] ao] Oo] dF WEN
BACKGROUND
MUSIC SOURCE
PS-12A or
PS-12C
Power Supply
AC
* PB-1 paging adaptor must be connected directly
to PS-12A (or PS-12C) power supply.
VARIATIONS TO STANDARD INSTALLATIONS
Any combination of TB-F series phones and accessories shown on page 2 of this manual can be intermixed to develop a
communication system to meet your requirements. Installation examples below show TB-6F as master station which may be
replaced by either TB-3F or TB-12F.
EXAMPLE NO. 1: TB-F SYSTEM WITH ONE MASTER AND SEVERAL SUBS
1) This example shows six TB-1F phones connected to one TB-6F.
2) Paging system may be added using PB-1 adaptor.
MASTER
STATION
TB-6F
SUB
TB-1F
лс <>
PS-12A or
PS-12C
Power Supply
EXAMPLE NO. 2: TB-F SYSTEM WITH TALKBACK PAGING
EQUIPMENT REQUIREMENTS
1) TB-F system shall consist of TB-1F, TB-3F, TB-6F or TB-12F phones.
2) One PS-12A (or PS-12C), one PB-1, one PB-2, one paging amplifier with 70 or 100 volt line and output of less than 50
watt RMS, and appropriate paging speakers as required must be used.
3) Door station may be included in system with paging or talkback paging.
NOTE: * PB-1 and PB-2 paging adaptors must be connected directly to PS-12A (or PS-12C) power supply.
* For full information please refer to PB-2 instruction sheet. NON-POLARIZED
STATION
7
STATION STATION STATION STATION STATION STATION
1 2 3 4 5 6
TALKBACK
PAGING
SPEAKER
[OA [A
NON-POLARIZED
PG-A or PG-B
PAGING AMP
TB-6F TB-6F TB-6F TB-6F TB-6F TB-6F 1B-6F
a
BACKGROUND
MUSIC
SOURCE
PS-12A or
PS-12C
Power Supply
EXAMPLE NO. 3: TB-F SYSTEM WITH 2 DOOR STATIONS AND
ELECTRIC DOOR RELEASE
e Maximum of 2 door stations may be connected to up to 12 phones per system.
NOTES: (1) DB-U door station adaptor must be connected directly to PS-12A (PS-12C) power supply.
(2) Be sure to connect |D] and |P| terminals on each phone for communication with door station
(paging may be added in a system incorporating door station).
(3) Do not use #1 terminal on any TB-F phone for connecting CF terminal on DB-U.
In this example button #5 allows conversation with door station #(1), button #6, with door
station #(2) and each station number button operates door release.
DOOR STATION
En # 2
1
2
DB-U Set call tone switch
in B position
Set cali tone switch с
[2
in B position.
STATION STATION
STATION STATION
4 3
2 1
NON-POLARIZED TB-6F TB.6F TB.6F TB.6F
e Set call tone switch
#1) " | DB-U in A position
OR STATION
DO ©) 3
1
2
NON-POLARIZED
EL-95
YELLOW
AC
YELLOW
BELL TRANSFORMER
12-16V AC (NOT
SUPPLIED BY A{PHONE)
25 REQUIRED TO POWER
AC DOOR LOCK.
PS-12A or
PS-12C
Power Supply
* PLEASE SELECT THE MOST SUITABLE DOOR
IC-DC IC-NA IC-RA IC-KA IC-JA IC-FY
EXAMPLE NO. 4: TB-F SYSTEM WITH EXTERNAL SIGNALING DEVICE
1) When TB-F phone is located in very noisy area (station No. 7 in this example), an incoming call may be extended
by external signaling device such as bell or buzzer using RY-AC.
2) External signaling device (not supplied by Aiphone) should not exceed 0.3A 240V AC or 1.0A 24V DC.
EXTERNAL SIGNALING DEVICE
NOT TO EXCEED 0.3A 240Y AC
STATION
7
STATION STATION STATION STATION STATION STATION
1 2 3 4 5 6
O
TB-6F
TB-6F
TB-6F TB-6F TB-6F TB-6F TB-6F
TO EXTERNAL
POWER
SOURCE
| YELLOW
YELLOW
AC
PS-12A or
PS-12C
Power Supply
OPERATION
CALLING:
Pick up the handset and momentarily depress the selector button of desired station.
RECEIVING:
An incoming call is announced by an electronic tone. Pick up the handset and begin speaking. When called from door, pick
up the handset, press the selector button corresponding to door station and begin speaking.
NOTE: Do not depress paging button while talking with other phone. When pressed it will cut phone communication or, if
paging system is installed, your voice will be broadcast over paging speakers.
PAGING:
Pick up the handset and make announcement by pushing and holding the paging button. Background music will automatical-
ly cut out during paging operation.
TALKBACK PAGING:
Depress the paging button for announcement and release for talkback.
NOTE: Talkback paging must be made with no phone-to-phone communication present since distortion will occur.
kkk
We at AIPHONE are proud of our products. Our designers and engineers strive to bring you the finest in communication
equipment. Each item has been carefully tested and inspected before leaving our factory. Properly installed and used, your
Aiphone intercom system should give years of trouble-free service.
We are pleased to offer the following warranty:
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal
use and service for a period of one year after delivery to the ultimate user and will repair free of
charge or replace at no charge, should it become defective upon which examination shall disclose
to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final
decision whether there is a defect in materials and/or workmanship; and whether or not the prod-
uct is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect,
accident, or to use in violation of instructions furnished, nor extended to units which have been
repaired or altered outside of the factory.
This warranty does not cover batteries or damage caused by batteries used in connection with the
product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place des-
ignated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on
site service calls.
Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, Washington En ane
T8-F-1-0986 KW Al PHON E
HOME, BUSINESS, INDUSTRY
Printed in Japan (E)
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement