Aiphone GF-2P User's Manual

Aiphone GF-2P User's Manual
 0801(A) 2 Al PHON E°
TWO-WIRE BUS APARTMENT SYSTEM
GF SYSTEM
INSTALLATION MANUAL
This Manual is enclosed in GF-BC, Bus a
Control Unit box. Operation Manual is Е So Panel
enclosed in GF-1D Apartment Station box. ee GF-SW & GF-1 - 4P
| 5" Call SW, module & Panel
Before actually installing the equipment, |
the contents of this Manual must be == GF-2F or GF-3F
thoroughly read and understood. => 2- or 3-module Front frame
After installation, please keep the GF-BC = GF-1D | =~ о GF-28 or GF-3B
Installation Manual, containing Bus control unit =) Apartment station ~—10| || 2- or 3-module Back box
instructions for wiring & programming, | —9|
as well as WARRANTY. fi оО
Precautions on Installation & Wiring
A WARNING (Negligence could result in death or serious injury to people)
A CAUTION (Negligence could result in injury to people or damage to property)
Q General Prohibitions © Prohibitions to subject the unit to water
Y Prohibitions to dismantle the unit
AN WARNING 1. These devices are electrical. Wiring must be performed by qualified personnel. O
2. Do not modify or alter the equipment.
3. Do not connect any power source other than specified to terminals +, —. Doing so may O
cause fire or damage the unit.
4. The equipment must not be exposed to water or any other liquid. ©
5. Make sure wires are connected properly before plugging the power supply into an electrical outlet. CS
6. AC outlet must be away from moisture and dust. ®
/N\ CAUTION 1. Do not install or make any wire terminations while power supply is plugged in, or it could cause O
electrical shock or damage the unit.
2. Mount the intercom on wall in a convenient location, but not where it could be bumped or jarred.
3. Do not install the unit in any of the following locations, as it may cause the system to malfunction:
- High or extreme cold temperature area:
under direct sunlight, near equipment that varies in temperature, in front of air-conditioner, inside a
refrigerated area, etc.
- Places subject to moisture or humidity extremes.
- Places subject to environmental conditions, such as oil, dust, chemicals, salt, etc.
- Places subject to constant vibration or impact.
GENERAL PRECAUTIONS
1. The equipment, except the entrance station, is designed for indoor use only. Do not install them outdoors.
2. The system is not operable during a power failure.
3. In areas where broadcasting station antennas are close by, intercom system may be affected by radio
frequency interference.
4. Keep all wiring at least 30cm, 1' away from AC100 ~ 240V wiring, fluorescent lighting, or dimmer switches.
Otherwise, cross AC wiring at a 90° angle.
-1-
SYSTEM COMPONENTS
Apartment station — Bus control unit & Power supply
~~ OPTION --- _ ~~ OPTION ----,
18 E. E 1 Ml
i A | O o |
| ' Doorbell Button | = | | |
| TOS em7 off Mm © о 1 |
S GF-1D GF-BC PS-24ME (AC 230V) PS-2410LC (AC 120V) : MAW-B |
Apartment station Two-wire Bus control unit — Power supply PS-2410LD (AC 230V) | Relayfor |
+ Packet of screws + Packet of screws + Packet of screws ı external light ı
VW * OPERATION MANUAL * INSTALLATION MANUAL e DIN rail QU *----7777777000 |
* Hexagonal wrench * Terminal cover
, * Fuse
Entrance station
FRONT FRAME PANEL ı MODULE BACK BOX
| ==
o_ se | =sssgssesss | | a
ho ре
pooonäoce | К 1
d о | | | |
- 7 |
GF-DP | GF-DA
Panel only | Speech module Л Т
| - Connector
|
e + — он |
|
| № е | |||
| —
GF-3F C0 СО | 3-module back box
3-module front frame | » Packet of screws
+ Mounting bracket GF-1P GF-2P | * Joint pipe (x 2)
* Packet of screws 1-call button panel — 2-call button panel | - Metal plate
* Weather stripping (for reinforcement) |
u_— Y | =
о JO Do not discard.
C0 — 0 | GF-SW
CO — 0 | Call switch module
CC A * Directory car
a © © | (plate & paper)
GF-3P GF-4P | * Connector
3-call button panel 4-call button panel |
nn
oo l= > Ц О |
2-module front frame | GF-2B
Mounting bracket | | 2-module back box
» Weather stripping (for reinforcement) GF-BP GF-AP | GF-AD + Packet of screws
--- OPTION --------------- Blank panel Address panel | Address module - vo Pe (x2)
| |< Directory card etal plate
GF-H Rain hood | (plate & paper)
+ GF-C 80cm (3-1/8") | | + Connector
МК с onnecting wire BN [ | Do not discard.
Open a hole in the wall for mounting back box (es).
It is suggested to mount the back box at the height of 150cm (5') (up to box center).
Allow a space of 2mm (1/8") or more on each side of back box in the wall.
BACK BOX DIMENSIONS
EXAMPLES Module back b bled
* Two-module back boxes (x2) + Three-module back boxes (x3) odule back boxes assemble
Joint pipe (ea.2) Back boxes W (mm) W (inch)
| , One row 110 4-5/16"
Joint pipe (2) prt | | =) Two rows 245 9-5/8"
E | ° Three rows 380 15"
Four rows 515 20-1/4"
275mm Five rows 650 25-9/16"
(11-5/8") Six rows 785 30-7/8"
Seven rows 920 36-1/4"
a a Eight rows 1055 41-9/16"
bg i pyre I py Nine rows 1190 46-1/8"
25mm 25mm For best results, the back box(es) must be
(1 (17) mounted strictly horizontally.
44mm N W 44mm
(1-3/4") (1-3/4")
Mount back box not more than Mount back box not more than
15mm (1/2") in recess. 15mm (1/2") in recess. 9
MOUNTING ENTRANCE STATION
Front frame & panels Modules on bracket
Sa | Joint pipe
ASIA
Lt Ade pdt
LILI FLIES
CHE
[FY ENN
o
|
f
+
©
+ Joint pipe
Assemble panels of speech &
call SW. modules into front
frame from the back. |
Pl
— =
-
(ОЕ
Hexagonal wrench
-
Crreeeeeeeeeeeeeeeeeeeeeeeeees (supplied w/GF-BC) / /
| Attach the Modules onto Plug the wires into connectors
Mounting Bracket. between the Modules. |
| Sy —
>> Z Remove terminal cover. el
> 3
| y a
i > Always run the wire |,
_ under the plastic cover | |
for drainage. |
Interconnecting Modules with Plug-in Connectors
As shown, the Modules 1 Connect the Modules 2 Pass the connecting wire through joint pipe (pre-
must be connected in a as shown in drawings. opened), and plug to CN1 of Call SW. of next row.
daisy-chained manner. Eo ES |
I Next
Speech module
Badkeviewn* — — /
| CN4
| CN1
| CN?
Call SW. CN! |
modules ( = _ Call SW. CN2
modules | | CN1
CN
—" Lin | > CN
Back view e A | eN?
Locating Speech module (GF-DA) à f ar
ı In the middle row > == ESA |
| J ПСБ ЩО
GF-C, 80cm(3-1/8") —— ИДИ
| connecting wire | 1 (В No
| | GF-3B || || GF-a8 || || GF-æ !
ı In advance, pass a 80cm(3-1/8") long | | | | | | |
' connecting wire through joint pipes. |
MOUNTING & WIRING
GF Entrance Station
(Entrance station #1)
GF-DA Speech Module
Back view
SETTING
manner.
Entrance station #1
Entrance # SET switches
To set for Entrance stations #1 ~ 5, set DIP switches on Speech Module (GF-DA) as
shown below. All the Entrance stations will malfunction if positioned in any other
Entrance station 42 — Entrance station 43 Entrance station #4 Entrance station #5
Teed
“000 [5555
“205
“207
Door release timer
Mid-point
20 range
| A
Momentary
Shipped in "#1" position.
Shipped in "Momentary" position.
0.5 | 0.5 sec. duration;
Turn counterclockwise completely.
— 0.5 ~ 20 sec. duration;
Turn clockwise to obtain longer second
of duration.
20 | 20 sec. duration;
Turn up to the mid-point.
M | Momentary activation(*);
Turn to any point between 20 - M.
(*) Activated as long as the door release button is held down.
(R1R2|ELIEL| + | b |
oa aaa
EC
FAN
GF-DA
Back view
5P connector
from upper socket
of a module below
Put a conductor into insert-
lock terminals.
*To release a conductor,
press UNLOCK button,
then pull the conductor.
UNLOCK button
YY
АС — >
to MAW-B/Light of Entrance 1
(See page 5 for wiring)
| AC/DC 24V
less than 4A
wl (resistance load)
Electric Door release
(Entrance station #2)
Speech Module
AC/DC 24V
less than 4A
(resistance load)
Electric Door release
PT: Power transformer
When mounting multiple rows of panels,
attach the metal plates and tighten screws on
the brackets.
Metal plate
Mounting
bracket
qe Æ e) — ©)
| © y ®
Adjustable — =
screw holes ——
Щ
A Metal plate H
After wiring & setting, mount the
module-mounted bracket to back box.
Finally, attach front frame/panel to
the bracket.
|
y
EE
un
7
|
|
|
J Hexagonal
h
wrenc
Light
> To next apartmens
APARTMENT > Р
(See next page.)
> To next apartmens
NP LY
7
AC power line
GF-BC
CONTROL = = - ——— PS-24ME
Pour Te
O
SUPPLY CTO IA
SUPPLY
AAAAAAA
= + _ 0.9A output
Red | | Black
а (+ —
White A ) \ О
YU
tion
Blue --N---#----- Opt on
(unused)! i
Junction point | || MAW-B |
| Rela |
---- 8 2| 1 Ri NP | у |
a oo в „< OA eo 00 J
R2 .
Light control Orange / | Orange
TIMER | ©
For controlling light at the entrance,
AC use Aiphone's MAW-B relay, which
provides dry closure contact.
PS-24ME
%* Screw hole
MOUNTING
Power
switch
Power on LED
> (green)
IN
DIN rail Pull down lever ESS | Сб №
DIN rail for GF-BC: —
W-DIN11 available from Aiphone * Use when DIN rail is not provided.
HOW TO RESET BREAKER (Power switch)
ON Power
When system malfunctions, check the wiring. Check the fuse of power supply. OFF switch
Turn off the power switch of GF-BC and turn on again, resetting the whole
system operation. =, — Green LED lit
vw ий
-5-
Apartment station
> Apartment 3 ~
Apartment 1
Apartment 2
Chassis
*1
inside view
=
+ *1: Doctor call (Auto door strike upon
visiting patient call-in)
JP1
>
At the Apartment station remove JP1
jumper. Press LIGHT button and see
Call tone off indicator blinks. Press
LIGHT again to release. Call tone off
| Note; At the station set for Doctor
Cable — | > indicator goes out.
inlet hole coceseeserrees 7
call, it is not possible to control
fe eo em em em mmm mmm mm mmm mm me ee eee ee ee ee em ee mmm J entrance light with LIGHT
9 button.
I 3.2 kh» *2: Connect Doorbell Button only to
Г ol p——t—p- [0 Bus control unit either one of two apartment
stations to avoid malfunction.
Junction point Provides dry closure contact for
Employ a terminal block of adequate ringing while the Doorbell button
size to distribute multiple Bus lines. — ishelddown. _ |
fo GF-DA Speech Module
Adjusting call tone volume (or off) MOUNTING
Call tone volume can be adjusted to 3 positons: It is suggested to mount the station at the height of 150cm (5') from the floor.
MUTED - MID - HIGH. When the control is set to +4
MUTED position, Call tone off indicator blinks.
Call tone volume
control
| И
\
MUTED + MID + HIGH
Bottom view
Notes;
*1: Cut out a hole for surface
cable run.
*2: SERVICE button terminal
block & switch is optional.
83.5mm *3: To avoid pinching, keep wires
(3-5/16") away from PC board section.
Handset
NS
*2
or round
gang-box
. Loosen a screw on front case.
Lift the front case off the chassis, and pull it away.
. Mount chassis on an electrical box.
. Connect incoming wires on terminal block.
. Remount front case on chassis, tightening the screw.
SETTING UP SYSTEM
Prior to setting up GF system, make sure all the stations have been installed
and wired in proper manner. Leave the front frame & module panels unattached.
Step 1 Press PROGRAM switch on GF-DA Speech Module. open the rubber cap. Then push
o PROGRAM SW. momentarily.
When front panels are
already mounted, open
unscrewing the bottom
Turn on power switch
of GF-BC.
Power switch (Breaker) | screw. | Hexagonal TAN
| Г SETTING FOR "LIGHT"
4 ; button (OPTION)
| = | _— In-use LED
| 3 | = do
LESS "| In-use LED ei.
O ID || Wait for approx. 15 sec. Sete,
| = | and see the LED steadily lit. While | de bli к
8 ' ci Bi ile In-use blinks
| RS opm of Blinks for ls (within 15 sec.), press an
| - | "ee ' —@— assigned call button.
| Unscrew | rm > Y IN
| | Note; At the rest Entrance stations,
ı Hexagonal wrench ' the in-use LED is steadily lit and
E blocks out any calling.
Step 2 Atan Apartment station #1, lift handset. Communication channel is
established with Entrance station instantly. Hearing single BEEP tone
means the station correctly set. Hang up handset.
Apartment station #1 Entrance station
BEEP TONE
BEEP tone
=) + LIGHT button is set.
| (Turns on entrance light,
7 00 controlled by MAW-B
| Y relay.)
Hexagonal wrench
Press a first call button
Fora second station, if installed, lift second handset and press the same call button 1.
Beep tone sounds twice.
Second Apartment station #1 Entrance station
: DOUBLE BEEP TONE |
ı = Call button 1- Apartment 1 - 2 is set. |
Hexagonal wrench
Press a first call button
Step 3 Go to each apartment consecutively, and program each handset station in the same manner as in Step 2.
Step 4 when completed, press PROGRAM switch on [== Do not forget to replace
GF-DA Speech Module again to finish the N the rubber cap.
programming.
— To correct wrong setting
Apartment station Entrance station
Lift handset. Keep pressing a call button to clear until a continuous tone is heard.
(Consecutively, operate same way for next call button, if any)
|
eo. | y Following Step 2,
=» er =) Reset on apartment station(s) that have been cleared.
Tm For 2-station apartment
e Clearing a call button cancels programming for
two stations, correctly set or not. Individually
reprogram both stations.
- 0 O
TECHNICAL PRECAUTIONS
Temperature GF Entrance station: —10°C ~ +60°C (+14°F ~ +140°F).
GF-BC: 0°C ~ +40°C (+32°F ~ +104°F).
GF-1D: 0°C ~ +40°C (+32°F ~ +104°F).
GF Entrance station is weather-resistant, but for best results, it should be protected
from direct weather conditions. Install a rain hood (GF-H) to protect it from direct rainfall.
Fill in directory or address on the transparent plate with an oil-soluble pen, etc. and attach the
plate to module. _
Plate (*) or paper
Rain hood (option)
Filling in name &
address
gr re,
Bit,
a, y
Can, ден
1 ” Plate (*) or paper
— Address module
Before mounting the plate,
peel off protective film.
Call SW. module
Pressing on either side,
remove directory plate
Pressing on either side,
remove address plate or
or paper. paper.
Setting up after In case an apartment station is replaced after all the wiring is done, turn the power switch off
replacement and back on again on GF-BC. Then reprogram that apartment station only.
Operations At the end of communication, hang up the handset on cradle. If a handset is off the hook, call
tone will still ring at two stations. But for approx. 45 sec. after called, the inside audio is
activated on that apartment station and heard at the entrance. Momentarily hang up handset,
and resume communication.
While an apartment station rings with a call from an entrance station, a call from the doorbell
button will not be heard.
Cleaning Clean GF equipment with a soft cloth dampened with neutral household cleanser.
Never use any abrasive cleaner or cloth.
SPECIFICATIONS
Power source: DC 24V (GF-BC), supplied by PS-24ME or a power supply as specified.
- Current consumption: Max. 700mA. Standby: 30mA (8-call, one entrance).
» Call-in tone: Two types of call tones, one from entrance station, the other from doorbell button, distinguishable
* Talk path: Single channel, non-open.
* Communication: Simultaneous with handset (no calling or communication between apartment stations).
* Wiring: 2 wires common Bus, GF-BC to Entrance station(s) & Apartment stations via junction point
throughout system.
* Type of Cable: 2 conductors, solid copper & non-braided, polyethylene insulation, 0.8mm dia. ~ 1.6mm dia.
(20AWG - 14AWG).
* Wiring distance: Diameter of wires 0.8mm dia. 20AWG
* Junction point to GF-1D (farthest) 300m 980"
* Junction point to Entrance station 300m 980'
* Total wiring distance 2,500m 1.5 miles
* GF-BC to Power supply 5m 16'
* GF-BC to Junction point 5m 16'
* MAW-B to each GF-DA, light & power supply 300m 980"
Multiple Bus lines (divided at junction point).
* Apartment station: max. 50 on a Bus line.
* Entrance station: max. 3 on a Bus line.
Per system: 150 pes in total
Per apartment: max. 2 pcs
Per system: max. 5 pcs GF-DA
Per panel: max. 25 pcs GF-SW
- Door release terminals: EL, EL rated less than 4A (resistance load), AC/DC 24V, for dry closure contact for door release.
JA dd tdt dd td det dote dde dede ted dede dde todo te dede dee dede dede dede dede dede dede de te dote dede dodo state
+ WARRANTY
+ Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period
= of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective
+ upon which examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make
+ the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the
warranty.
+ This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation
+ of instructions furnished, nor extended to units which have been repaired or altered outside of the factory.
+ This warranty does not cover batteries or damage caused by batteries used in connection with the unit.
+ This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
de * Aiphone will not be responsible for any costs incurred involving on site service calls.
oto vie sie ois jo nto ajo ta ajo to ojo eto aja ajo to sie nto ojo ojo ta jo ja ojo ja rta eto 03e ato slo je ato ajo elo fo ajo fo eto ajo to ajo ojo efe ajo to efe ato elo jojo efecto efe foto fo cto ajo to ajo fo to ajo ote
AIPHONE CO., LTD., NAGOYA, JAPAN
“> AIPHONE*
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE EUROPE N.V., ANTWERP, BELGIUM
Providing Peace of Mind
Printed in Thailand (E)
Bus line capacity:
Station capacity:
Apartment station:
Entrance station:
FEE EEF Ebb bbb
GF-I/M(E) 0801A