Aiphone MY-CU User's Manual

Aiphone MY-CU User's Manual
 53534400 0550 E» AIPHONE
( PanTilt MY Series В
~ VIDEO-MONITOR, single entry
MY-CU
MYH-CU
INSTALLATION & OPERATION MANUAL
Models:
a
CONTENTS
1 SYSTEM OUTLINE & COMPONENTS.........…………rrrecrcereecererre mere nina nemeranae ne neen era aa rene ea rene ra nee ea 1
2 NAMES € FEATURES .....................emieeeneiniener re rnenee re reneene recen enn eree reee ner eeeerrrrnneaerrinrraerr rare nerrrarrneeaeee mes 2
3 PRECAUTIONS ON INSTALLATION 8% WIRING............ ee... veneno e nee rare eee 3
U TS 4-9
5 MON TINGersrer ern re EEE ERERKRKREKKRRERERLEREEERRKRKERKEKREERRRRRKEEKRTRRRERREERRREKRREREEEERERRREREREER RER 10
6 OPERATIONS on MY-CU 8 MYH-CU................2. meme carre annennaasnemanr aan ae ee era n nee nana naar are 11
7 BEFORE ASKING FOR REPAIR .... eit eee eee eee e eset eee en essere annie 12
000) CT eens 12
SYSTEM OUTLINE & COMPONENTS
MY-CU is a video monitor unit to enable an intercom to verify callers at a single PanTilt entry.
- MYH-CU is a sub-monitor, to increase monitor location.
PanTilt door MY-CU MYH-CU 1 MYH-CU 2
station
Jumper wire(s)
to (main) ~~
intercom
PS-18C/D
E Components available x Prerun 8-conductor cable to extend
distance to MYH-CU 2. (See page 12)
MY-CU MY H-CU
Room monitor (sub) monitor
H Package contents
Video-monitor (MY-CU or MYH-CU)
Mounting template
Packet of screws
Installation & Operation Manual
Identically designed with Panftilt control pad.
Intercom combinable
e Chime tone intercoms
e PanTilt door station
IE-1GD(U)
: MY-DC
IE-2AD(U)
frs
MY-FA MY-CA MYW-CA
_ 7
Plus IF-DA
for audio
2 door, 3 calls
1 door, 3 calls 2 door, 6 calls
Other MY Series: MY-DG, MY-EA. Wide-angle MY-DS.
* Selective call intercoms
TD-H/A or B LEF * Expanded system
| MYW-P3CB MYW-BA
3-camera adaptor | Long-distance adaptor
1-2 doors, 1-3 doors, | i
3, 6, 12, 24 calls 5, 10 calls :
|
DE-UR MYW-P1L MYW-P3L =
= Works with More than 100 m,
3 |E-8MD and TD-H/A 330’ application with
orB PE insulation cable
For each door 1-camera 3-camera
* Also, refer to the Manuals of using intercom and
adaptor.
NAMES AND FEATURES
Unitized design enables wall-mounting
attachedly to either side of intercom, or
separately.
Video monitor
(4”CRT)
210mm
8-1/4 Panáilt control
Backlight control
Brightness
+ | Contrast
Monitor
MY-CU, 50mm
MYH-CU 155mm 2”
6-1/8”
Ш Features
* One PanTilt door system
One to 3 room monitors, expandable
* Any monitor equipped with Pan/tilt, Backlight and Monitor buttons
Monitor button sees image handsfree, or extends viewing
Separate brightness & contrast adjusting
—_9_
PRECAUTIONS ON INSTALLATION & WIRING
/\ CAUTION
Xx Do not connect any terminal on any unit to AC power lines to prevent fire or unit damage.
Xx High voltage is present on the monitor unit inside.
Do not open MY-CU/MYH-CU without first unplugging the power supply, to prevent electric
shock. |
Xx Do not attempt to install or connect wires on MY-CU equipment while system's power supply is
plugged in.
Xx MY-CU and related equipment, except door station, are designed for indoor use only. Do not install
outdoors. |
* Do not connect any other power source than specified on terminals +, —. Doing so can damage the
MY-CU equipment.
x For system’s installation, there is no need to disassemble the equipment. Do not open any MY-CU
system components unless properly qualified. |
* Any other manufacturer's products installed with this system (door release, external signalling device,
etc.) are not covered under Aiphone’s warranty.
* Do not mount MY-CU equipment in the following places, as it may cause the system to malfunction:
* High or extreme cold temperature areas: under direct sunlight, near equipment that varies in
temperature, in front of air-conditioner, inside a refrigerated area, etc.
* Places subject to moisture or humidity extremes.
* Places subject to environmental conditions, such as dust, oil, chemicals, etc.
* MY-CU is an electrical device, which must not be subjected to water, or any other liquid.
* Weather conditions, such as lightning storms, may cause damage to MY-CU equipment. We
recommend that power surge protection be instalied as follows: (However, this does not guarantee
that no damage will occur).
If the power supply has a
GROUND terminal, take it to an
earth ground. In this case, a
separate surge arrester is not PS-18D
necessary. PS-18C
HA
M Before actually installing the MY-CU system, the contents on pages 4 - 10 must be thoroughly
read and understood.
a Fo)
H Single-entry, multiple-monitor system
H Cable requirements
PanTilt door station
Room monitors
MY-CU is capable of connecting one PanTilt door station and two additional
MYH-CU sub monitors.
It can be further expanded with an additional MYH-CU('s), by locating a power
supply(ies) for every 4 MYH-CU('s) (total 10 monitors).
Use a single pair (parallel) cable. Coaxial cable or 2 separate wires can not be
used. When existing doorbell or chime wires must be used, locate and
disconnect the bell transformer from the wires. Extra pair(s) in the installed
cable to video door station can affect the image quality, and must be terminated
with a 120 ohm resistor at each end of wires on both video door station and
video monitor(s).
YES NO
ВАА:
a
SES
EN
Parallel cable Coaxial cable 120 ohm = = . - a
Ai - AT]
po a po Coss
Use 6-conductor (parallel) cable, 0.65 - 1.0 mm dia., 22 ~ 18AWG. The video
cable must be separately sheathed from intercom’s (any), running from monitor
to monitor without any reconnections on other junction. Max. 75 m, 250° is
allowed from MY-CU to farthest MYH-CU in any configuration with 1.0 mm dia.,
18AWG. When locating a third monitor (MYH-CU) up to 75 m, 250" away, 8-
conductor cable must be run monitor to monitor, as each +, — wire has to be
doubled. |
* For proper operations, MYH-CU must be be fed 15.5V ~ 19.1V.
M Terminal block layout
©
SEE
H Impedance-matching
Impedance-matching
switch
Mo Te Meaning of terminal symbols
| ©® TE 1А1, 1А2: For video & audio signals
of 1 B1,B2 : For video output
Оба
C= у +, — : For power supply
el U1 : For output control
.
| ||| uned U? : For input control
ve del - - =
Poe + D1 : For audio signal & image on
Se = D2 : For detecting calling at
5) IF-DA 8: image off
| © T E : For common line
ee ey G : Grounding
When MY-CU has an MYH-CU sub-monitor(s),
| locate a switch to lower OFF on all MYH-CU(s),
while the initial ON may remain unchanged on
the last MYH-CU to terminate.
H Power supply
Use a PS-18D (PS-18C in North America) power supply(ies) to power entire MY-CU system. Do not
intermixedly use other manufacturer's.
1 2
MY-CU MYH-C
IE-8BMD J vo
or other ” — t+ _Ÿ | PE
и Y Do not connect
+ terminal between i
monitors 3 and 4
[E]
* MY-CU must be — (nor between 7and 8) (©) | ==
used with (main) PS-18C or —— PS-18C or
intercom in any PS-18D PS-18D
system. x Impedance-matching: Set the switch to OFF on ali MYH-CU's
except on the farthest.
Xx Locate a 2nd PS-18C (PS-18D) at mid point MYH-CU 4—7.
1 2 3
Ш WIRING DIAGRAM |
¡E-IGD(U) with an MY-CU monitor
/ ``
Master intercom & D(U)
Any PanTilt door monitor
Al
yi и
Ш)
6 MYH-CU (2 pcs) A
Sub-handset(s) A2
IE-2AD(U) only
N
PanTilt MY-CA mounts in place of an IF-DA. Connect
MY-CA and MY-CU with the (installed) 2 wires.
Uses a PS-18D(PS-18C) power supply only.
IEH-1CD
IEH-1CD
IF-DA
IE-2AD(U) can connect a 2nd audio door on D2,
E2 terminals. Add a jumper between D2 — D2 of
IE-2AD(UYMY-CU.
„== —
To EL-9S
door release <————
Ш Wiring distance
* MY-CU to PanTilt door * Two farthest stations (any pair)
Diameter 0.65mm 0.8mm 1.0mm Diameter 0.65mm 0.8mm 1.0mm
Distance 50m 70m 100m Distance 75m 120m 190m
AWG 22AWG | 20AWG |18AWG AWG 22AWG | 20AWG | 18AWG
Distance 165° 230 330” Distance 250” 380 630’
E PanTilt IE-8MD with 2 video-monitors
a
Any PanTilt door
IE-8HD
& MYH-CU
At second door
IE-8HD IE-8HD
STATION #
A1
A?
To acommon
PS-18D (180) |
See * connecting jumpers ab
E Wiring distance
me
x Single PS-18C or PS-18D powers both IE-
8MD and MY-CU, locating an MYH-CU on
75m, 245’.
One to 5 IE-8HD with 4-wire cable, station-to-
station. Pan Tilt MY-CU monitor with 6-wire cable
separately sheathed. Pantilt door requires 2
parallel wires, connected directly to MY-CU
monitor.
% Connecting jumpers
In single PS-18C(D) sourced system, a
D1 — D1 jumper is only required. Add another
D2 — D2 when {F-DA is installed.
Install a third jumper on E — E1, when a
separate audio & video power source is used.
_
E? } IE-8HD
- To audio — п т
IF-DA 5 7
3 3
4 Е
PS-18C + Es N
PS-18D| = — HE
(common) e 456
вх
* Impedance-maiching switch
UT
[U2]
2 ju
Mpers \E-8MD
D1
El -> |El
| Da 22
и
Remains a
= Switch location of
station + assigned
* MY-CU to PanTilt door e IE-8MD to audio door station
Diameter 0.65mm 0.8mm 1.0mm Diameter 0.65mm | 0.8mm 1.0mm
Distance 50m 70m 100m Distance 150m 230m 360m
AWG 22ANG 20AWG 18AWG AWG 22AWG | 20AWG | 18AWG
Distance 165” 230 330° Distance 500° 750 1,180’
* MY-CU to farhest MYH-CU (2 monitors) * Two farthest stations (any pair)
Diameter 0.65mm 0.8mm 1.0mm Diameter 0.65mm 0.8mm 1.0mm
Distance 35m 50m 75m Distance 75m 120m 190m
AWG 22AWG | 20AWG | 18AWG AWG 22AWG | 20AWG | 18AWG
Distance 115’ 160’ 250° Distance 250” 380° 630’
Diameter
Distance
1.0mm
5m
* MY-CU/1E-8MD to power supply PS-18D(C)
AWG
18AWG
Distance
16’
—6—
HB PanTilt video integration to TD-H/A or B
0 MY-DC MYCU— MYhCU — MYH-CU D The DE-UR adaptor connects MY-CU system
2 En 68) Е] 6(8) = in the middle point of TD-H/A or B installation.
3 common + No. of TD-H
stations/adaptors installed
„и
MYH-CU 1
yg — E
1A2| | B2 1А2| | В2 1A2
U1 [U1] U1
U2 U2 U2
+ + + *
NS PS-18D | Setto Remains
> L=\ (PS-18C)
TD-6H © TD-6H
=] D1 — 1] =
Ho — o] [5]
% Strictly observe that DE-UR + [+] - — ES ES
15 adjacently installed to the a — 5 — l=] EH
PS-12A/12C, so as to be A : о
powered from it. * PS-12A HZ]
(PS-12C) NL 8 Я
M Wiring distance
AC trans.
From DE-UR to power supply
Diameter 0.65mm 0.8mm 1.0mm
Distance 10m 15m 20m
AWG 22ANG | 20AWG 18AWG
Distance 30 50° 45’
* From MY-CU to power supply
Diameter 1.0mm
Distance 5m
AWG 18AWG
Distance 16’
* From MY-CU to PanTilt door MY-DC
Diameter 0.65mm 0.8mm 1.0mm
Distance 50m 70m 100m
| AWG | 22ANG | 20AWG | 18AWG
Distance 165’ 230 330’
7 —
Between TD-H intercoms (any pair)
Impedance-
matching
switch
Diameter 0.65mm 0.8mm 1.0mm
Distance 650m 1,000m | 1,500m
AWG 22ANG | 20AWG | 18AWG
Distance 2,000 3,000 4,300
From MY-CU to MYH-CU #1 (2 monitors)
Diameter 0.65mm 0.8mm 1.0mm
Distance 35m 50m 75m
AWG 22AWG | 20AWG | 18AWG
Distance 115 160 250
From MY-CU to MYH-CU #2 (3 monitors)
Diameter 0.65mm 0.8mm 1.0mm
Distance 17m 25m 45m
AWG 22AWG | 20AWG | 18AWG
Distance 55’ 80” 145°
HB LEFT-10 3-PanTilt entry system
7
PanTilt(any) on of a video
al + x
i on
\_ `В Dir _tenl
MYW-P3L provides LEF-10 system with max. 3 PanTilt video doors, locating MYH-CU monitor 1 or 2 max.
75m, 250’ away. The door camera can either be PanTilt door MY-DC, etc., MY-CA camera in MYW-A
overhead enclosure, with audio IF-DA or camera alone. Locate MYW- P3L adaptor in the middle point of LEF-
system together with 2 power supplies, audio and video.
TT MYW-CA
MYW-P3L |
— IN (W/MY-CA)
A С »
1A1 |3A1
1A2| |3A2
B
2A1
РА2
B1
B2
vi]
U2
18V4
18V
LEF-10 LEF-10 LEF-10 ©
HE
EN il EN
ra 2] |
3 3 | 3 |
ка я 4
5 С 5
|6 | 6
7 — 7 | 7 |
8 | pc 8] al
9 DB 9 kl
10 DA 10] 10
| 2 | 15 | | 6
El E E El.
A A] A A]
Y | LY Y
+ LÉ. | +.
о PS-12A | [+ Fava a
este | fe
LL] E] LL | ce LL) LL LL]
Ke Kg Ke] Ke Ks Ke Ke
K9 K9| Ke] KB! 9 | Ko] Kg
K10 K10 Kio KA K10 K10 K10
— =) — — (=) — —
Bl Wiring distance
* From MYW-P3L to * From MYW-P3L to PanTilt camera (any) * From MYW-P3L to farthest MYH-CU monitor
2 power supplies (1 or 2-monitor)
Diameter | 1.0mm Diameter 0.65mm 0.8mm 1.0mm Diameter 0.65mm 0.8mm 1.0mm
Distance 5m Distance 50m 70m 100m Distance 35m 50m 75m
AWG 18AWG AWG 22AWG |¡20AWG | 18AWG AWG 22AWG | 20AWG | 18AWG
Distance 16” Distance 165' 230” 330” Distance 115” 150’ 250°
x For 2-monitor system only, double
wires on +, — terminals between MYW-
P3L and MYH-CU's.
Ш MY-CU with 3 PanTilt cameras (w/ MYW-P3CB)
4 MYH-CU MYH-CU ) This is an expanded MY-CU system that includes max. 3
| 7 PanTilt cameras. Intercom can be either IE Series or
TD-H/A or B TD-H/A or B.
1 2 3
x Locate MYW-P3CB and power supplies in the middle
y _ point of using intercom system.
MYW-P3CB
MYW-P3CB
MY-DC |MY-DC =
\ J
MYH-CU MYH-C
[FGH - 4
1A1 + ( )
Ао B1 1A1 —
B2 1A2 —
UN U1 U1
2A1 U2 U2 U2
2A2 + +] + XxX Impedance-
a Sort R — К matching
ЗА! et to: emains switch
3A2 = ei | |
— = TD-12H
1 Fr D1
2 +E1 Г E
[1] —D2
Le Ez) MZ |
a E3| PS-186D &
or — EN
2 | ' 222 — 2
3 4113 Г M3 13 —H_3 — 3
a Lata A 4
5 HS "STE = 15.
6 6 — +18 He HH = 6
Th Rs —
88 18888 — 8 6
e SINS Te Ey
10 110 FH 1 10 H—{10 10 H+ — 10
11 HH11H- cars —H 11}
212 br 12 rr 12 {12 {12 HER — 12
2 Hs ra Hs Hie e 7
DD] |) Ho eh mo he Di [D +
CHERE FE =
HO se ie =
PS-12A/12C
N DE-UR DE-UR HE Wiring distance
a Wiring door1 door2 * From MYW to PanTilt door
Diameter 0.65mm | 0.8mm 1.0mm
Distance 50 70 100
MYW-P3CB MYH-CU MYH-CU T T T
N AWG 22AWG |20AWG 18AWG
= Distance 165’ 230’ 330’
PS-18D(18C) 2
power supply
2
Ze
—_ |
oo
Pantilt door 1
> 2
Camera 3
2
—
2
—& Intercom(audio from door 1)
2 Intercom(do, door 2)
Ine Intercom{do, door 3, unused)
DE-UR 1
DE-UR 2
* From MYW to farthest MYH-CU monitor
(1 or 2-monitor)
Diameter 0.65mm 0.8mm 1.0mm
Distance 35m 50m 75m
AWG 22AWG | 20AWG | 18AWG
Distance 115 150” 250’
x For 2-monitor system only, double wires on +, —
terminals between MYW-P3CB and MYH-CU's.
From MYW to PS-18D(18C)
AWG
Distance
1.0mm
5m
Diameter
Distance
18AWG |
16’
MOUNTING
Ш Mounting MY-CU and MYH-CU
¥ Loosen 1
2
Push and
lift gently
front case
off the
chassis.
2-GANG BOX
NJ Screws(4) supplied
Ш Mounting with intercom
e For lE-1GD(U),
IE-2AD(U)
or TD-H/A or B Attach template supplied to wall.
Lg
i 1
3 EN I
1 Ш 1 1
= == TRE |!
ve NAW li
A '
1 + i
® i
1 . noi
1 Il
E EN à
Ñ ">
= 1
e
= o
1
1
pr— = —
1 L
1
1
i 1
|! \
', Y
| —
т
1
!
1
+ 4
T T
T
1
Template т
i
Arona Мо и
Two unit or box centers
To mount the MY (H)-CU monitor, separate the terminals-
mounted chassis from front case.
1.
Loosen a screw on top of front case.
Press on bottom, right hand, and the front case slightly
moves up.
Then, press on center of left side, which unlocks from
chassis.
Lift gently front case, then it separates.
Disconnect video-monitor. Pull off the holder and set
monitor aside.
Attach chassis to wall at 4 points.
Make wire terminations directly on 6 screw terminals.
On MY-CU only, wire with jumpers on audio terminals
D1, D2 & E. |
Pin the holder, reconnect and mount front case, justly
aligning to lock.
Do not connect any wires at any other point than on
terminals.
* For IE-8MD
and IE-BHD ¡E intercom ce
chassis TRS
= o
u TT
- MY-CU
MYH-CU
Chassis
Before actually mounting the unit, attach the supplied template to wall. For MY-CU/IE-8MD
combination, attach two chassis to wall. First, mount the intercom chassis (or bracket) to wall or single-
gang box, and MY-monitor chassis can adjustably be mounted to its right side.
203 mm, 8" measured between
MYH-CU
monitor 3~5 cm,
LEF-5, 10, 10S
intercom
two unit or box centers.
* For MYH-CU and LEF-5, 10, 10S
Mount MYH-CU to the left of LEF-5,
10, 10S intercom, keeping a space of
3 - 5 cm (1-1/4" - 2") for brightness/
contrast adjustment.
—10—
E
EEE
OPERATIONS on MY-CU & MYH-CU
T2
Ш MY-DC, DG image viewing area
pea
[1 : when camera is in still position. Video monitor
k———80m(6) ——
“A JOT TTT oT Tome ITA OIEA
ВЕ 600 Panttilt control
-. 66cm(26”) | Pa n r
90em(3”):- A — Brightness
/ NT Contrast
>
Y NARA ELA LL Monitor
Backlight control
E Pan/tilt control pad
When an image of entry is on the monitor, move door camera up
or down, side to side. Press on each edge of diamond-shaped
O pad, and door camera is panned and tilted to view max. 90cm
O high x 180cm wide (3° H x 6’ W) on the monitor screen.
Door camera Door camera
tilts down pans to right
Bl Backlight control & Monitor buttons
entry strongly backlit or when the entrance area is dim day or
night. Monitor button views image of entry handsfree for 2-1/2
O MONITOR MONITOR | 2nd and 3rd entry.
CoP — Pp
Backlight control button literally adjusts to brighten image of
BACKLIGHT
minutes (approx.). Press “Monitor” to turn off, or to view image of
E PanTilt door station call, monitor-activating
When a PanTilt door station has called, it turns on MY-CU and
MYH-CU sub-monitor(s). The image is kept on for approx. 45
seconds.
Chime,
Call tone
Answering station operates as follows;
A + On IE-1GD(U), IE-2AD(U) & IE-6MD; Simply pick up, seeing the image.
| « On TD-(3, 6, 12, 24) H/A or B; Pick up and select a # button assigned.
12 On LEF-(5, 10, 10S); select a # button assigned, putting
TD-H/A or B the station to listening mode. Depress
Talk button and make a reply.
The image auto-shuts off in 2-1/2 minutes (approx.).
Press Monitor button to resume.
HB Brightness & contrast controls
-- | 3-level . , ,
5 = | Mer Each brightness and contrast are 3-level adjustable.
в! Darker To view dim entry area, put contrast (lower switch) to
bottom H position, and slide down to decrease
5 brightness.
< 3-level
8 Medium
tT Strong
—11—
*
BEFORE ASKING FOR REPAIR
In case the system does not provide a satisfactory performance, possible causes may be; Unplugged? Disconnected wire?
Shorted wire? Consult the dealer or distributor that you purchased the product from.
video monitor. This is not a malfunction, and will return to normal shortly.
Refrain from spraying water at the door staton directly, regardless that the unit is designed to be weather-resistent.
Clean your MY-CU equipment by a soft cloth dampened with neutral household cleanser.
When the temperature outside lowers rapidly (after rain, etc.), the camera lens may be fogged and offer a dim image at the
SPECIFICATIONS
Power source DC 18V on MY-CU
Use a PS-18D power supply (PS-18C in North America).
Current consumption
Ш Panftilt viewing area shown by dotted line
System MY-CU MYH-CU 3-monitor
Max. 0.9A 0.4A 1.7A
Standby 0.12A 0A 0.12A
Video monitor 4” direct view flat CRT
Scanning line 525 lines
PanTilt door capacity
1 door 1E-1GD(U), IE-2AD(U), IE-8MD, TD-H/A or B, MYW-P1L (LEF)
2 doors MYW-P3CB (for IE, TD-H/A or B)
3 doors MYW-P3L (LEF)
29cm (117)
7 -200ст (677)
7 ’ -
и - -|-1710m (5'85 7 TES
7 E 90em (36) 7 Ост
ил CN _ DO
Ke 15] -1220m - - >
‘30cm 7 SK VTT com (86) <” 5 1825 >
(43”) ‚ Emm mm mmm dom он -- ед SOM
Camera 1! ı 12cm (5”) } — — (20)
center 4: | ¡57em (227) 66cm (26”) 1 57cm (227),
SA! | -————r180em (6) —
|
|
|
TITI
Ocm 50cm (207)
: Viewing area of camera in still position
Wiring Use 6 or 8-conductor (non-twisted) cable between monitors with no extra wires nor reconnections.
* To Pantilt door * 2 monitors
MY-DC MY-CU
2 cond. (parallel)
0.65mmé¢ 50m 0.65mmé 35m
0.8mm ¢ 70m 0.8mm ¢ 50m
1.0mm ¢ 100m 1.0mm ¢ 75m
| 22ANG 165” 22AWG 115’
20AWG 230 20AWG 160'
18AWG 330° 18AWG 250’
* 3 monitors
MY-CU
MYH-CU
0.65mm ¢ 17m 0.65mm ¢ 35m
0.8mmg 25m 0.8mm¢ 50m
1.0mmé 45m 1.0mmé 75m
22AWG 55’ 22AWG 115
20AWG 80’ 20AWG 160’
18AWG 145’ 18AWG 250’
MYH-CU
* 3 monitors
MY-CU
MYH-CU MYH-CU
* Wires on each +, — are doubled.
Dimensions (H x W xD)
Weight (approx.)
210 mm x 155 mm x 50 mm. 8-1/4” H x 6-1/8" Wx 2" D
MY-CU 1.0 Ка (2.20 Ibs.) MYH-CU 0.9 Ка (1.98 165.)
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are > designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
- guarantee that interference will not occur in a particular installation. If this equipment does cause harmful inteference to radio or television reception, which can
be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
~ * Reorient or relocate the receiving antenna.
ге Increase the separation between the equipment and. receiver.
* Connect the equipment: into.an outlet on a circuit different from that to which the receiver is connected.
. Consult the dealer or an experienced radio/TV technician for help.
Jo dB de dd dede e Le de e do de tdo de dt dd dd dE dd E oo br of wf ob fr <i +f de de de de de ee de dede de el e e de of oo fs of of of obs
нННННННННННННННННы
Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA
MY-CU-I(E) 0595D
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two
years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of
instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.
— 12 —
EAN
COMMUNICATION SYSTEMS
AIPHONE
HOME, BUSINESS, INDUSTRY.
Printed in Japan (E)
©
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement