Aiphone MYW-CA User's Manual

Aiphone MYW-CA User's Manual
| 83070400 1092 B << AIPHONE
PanTilt Separate Camera Adaptor a
M Y W-C A (Camera adaptor)
Model;
_ y
INSTALLATION MANUAL
MYW-CA is a surface-mount box for attaching MY-CA PanTilt video door station inside,
so that MY-CA can work as surveillance camera.
1. Removing the MY-CA chassis;
Loosen the tamper-proof screw on front case, and remove
the back frame. Unscrew at one point, and open the chassis.
Pull off CN102 connector, and then reattach the chassis.
ef |
INSIDE CHASSIS
WEATHER-STRIPPING
TAMPER-PROOF
MY-CA
NN CAMERA UNIT
BACK FRAME—
When reattaching the
chassis, be careful that
the weather-stripping
(string) should rest
attached. MY-CA |
Y
WEATHER-
STRIPPING
2. Connecting two leads to MY-CA;
Locate the MY-CA unit inside the MYW-CA box.
Connect two black and white leads to Al, A2 D d MYW-CA
terminals on MY-CA. BACK PLATE > MY-CA
Wiring 1s non-polarized. (without back frame)
Attach back plate with all 6 screws securely.
Remove a seal on camera cover before mounting MY-CA.
Be careful not to scratch the cover surface.
To clean, use soft cloth.
3. Installing the MYW-CA unit;
This shows an installation example of MYW-CA camera unit, | BROWN
| | о BLACK | to: Moti
along with IE-JA audio door station, and DP-600Z motion detector. WHITE | to; Motion detector
At the entry (under the eaves) no (Each pair wiring is non-polarized
De WOOD 1 ci,
MOTION DETECTOR HR | a
DP-600Z (Instructions „^^ SCREW (4)
furnished with
DP-6007)
to; Main video monito!
to; Audio door station
A INSIDE THE HOUSE...
a. TERMINAL BOARD
i 6-wire cable (locally available)
y (approx. 1.5m/5' long) ©" WIRE NUTS
Mounting accessories;
Attach the mounting base with 4 wood screws, and the
arm with hexagonal bolt.
Adjust MYW-CA direction
with these 2 screws and
the center hexagonal bolt.
WOOD SCREW (4) р
DU
The MYW-CA cable should be "U"-shaped 7 Bag = sf
to allow easy run off of water, etc. | HEXAGONAL BOLT—_ "55" =
AUDIO | : & WASHER ес ><
DOOR STATION N | SCREW & WASHER (2) Sager *
IE-JA 3 mee
As shown, mount the MYW-CA unit to the hardware supplied. and SCREW (6) for back plate
Provide a terminal board locally available, on which connect wires from main video monitor, motion detector & door station.
Water-proof the junction parts of the cable, if exposed.
MY-1CD,
MY-2CD,
MY-CU or
MYW-P3CB (MYH-CU)
1 x
a:
: 6
||
+
+
+
MYW-CA — 8-conductor cable — 2
2
IF-DA AT —
Ц
L la
J PS-18YC/18YD
DP-600Z #5» PS-18C/18D
J |
20m/1.0mm dia. 100m/1.0mm dia.
| 10m/0.65m dia. > 50m/0.65mm dia. ||
Г (65718AWG, — (330/18AWG, |
33'/22AWG) 165/22AWG)
ROOM STATION
- MY-1CD
TERMINAL BLUE TN
BOARD , O [1A1]
YELLOW NON-POLARIZED [142]
BLACK _
EE WHITE N
RED | =
Secure insulation between +
unused wires with viny! tape. BROWN =!
- À
IF-DA mm
AUDIO | |
DOOR Ol NON-POLARIZED
STATION "2
POWER SUPPLY
y PS-18C/D or
—j NON-POLARIZED ) Ps-18YC/D
IS,
DP-600Z |
MOTION > To: PS-18C/D [+ H—
DETECTOR or LOCAL POWER SUPPLY. E
NOTES;
(1) When motion detector and audio door station is not installed, have each BLACK/WHITE and RED/BROWN wires insulated.
(2) The locator LED is lit on the IE/IF door station, only when MY W-CA is working. 7 —— IF-DA
To cut off the LED all the time, open the case and remove either lead from the PC board.
(3) In MY-1CD system, use PS-18C/D power supply when DP-600Z is installed.
* Power source:
Supplied by main room station.
* Dimensions: H x W x D: 163 x 121 x 52 (6-1/2" x 4-3/4" x 2°)
* Weight: Approx. 850g (1.87 Ibs.) including mounting * Horizontal (panning)
accessories
8.4m/28'
* Max. distance to object: | It is suggested to locate the MY W-CA at approx.
3m/10' distance to the viewing area,
providing spotlighting illuminatin for the night.
N
ne \
* Image viewing area: At 3m/10' distance; 4.7m/16' vertically 8.4m/28' | | |
horizontally captured by pan-and-tilting operation The outer angle is obtained when camera is
pan-and-tilted, while the inner angle is for fixed
camera position.
Opeational notes;
In night time, pan-and-tilting operation may cause flickering on the monitor, bul this is not a unit disorder.
When the system with DP-600Z motion detector is powered on, it may happen that a call will be initiated by itself.
Wait for approx. 15 seconds after powered on, as the system performance can be unstable.
Aiphone Co., Ltd., Nagoya, Japan
COMMUNICATION SYSTEMS
Aiphone Corporation, Bellevue, WA, USA <> Al PHON E
HOME, BUSINESS, INDUSTRY.
MYW-CA-I(E) 1092B Printed in Japan (E)