Daikin - RW Wholesale
Daikin Air Conditioning Guide
Acton (London)
0208 896 9187
Bow (London)
0208 525 9888
Bristol
0117 977 2616
Birmingham
0121 328 1122
Chelmsford
01245 463 539
Dorset
01202 824 186
Edinburgh
01506 855 306
Exeter
01392 823 992
High Wycombe
01494 473 330
Hull
01482 974 500
Kent
01322 529 994
Nottingham
0115 986 6477
Daikin
Air Conditioning Guide
Issue 2
Daikin Air Conditioning
Suppliers
Daikin Air Conditioning
Suppliers
Refreshingly Different
Refreshingly Different
www.rw-wholesale.co.uk
www.rw-wholesale.co.uk
Conditions
Capacity Conditions
Seasonal Efficiency
Unit cooling and heating capacities shown within
this price list are based on the following conditions:
Split and Sky Air
Nominal cooling
Ambient = 35°C
Internal = 27°C db 19°C wb
Nominal heating
Ambient = 7°C db 6°C wb
Internal = 20°C db
UK cooling
Ambient = 30°C
Internal = 22°C db 16°C wb
Systems of up to 12kW must now show Seasonal
Efficiency Ratings instead of Nominal Efficiency Ratings.
These ratings (SEER for cooling, SCOP for heating)
represent how effective a system is throughout
the year, and are in accordance with EN14825.
For more information on Seasonal Efficiency,
visit www.daikin.co.uk/seasonal-efficiency
For Daikin UK, this means all our Split and Sky Air
products up to 12kW display SEER and SCOP data along
with Energy Label information and Annual Energy
Consumption of the system. The AEC is based upon
500 hours use per year.
VRV (ESEER)
Heat Source
ESEER is defined as the European Seasonal Energy
Efficiency Ratio and is a measure of the performance of
the outdoor unit only.
Unless otherwise indicated, all units within this
price list are air-cooled.
Nominal Efficiency
This measure of efficiency is calculated by dividing the
capacity output of a unit by the power required to deliver it.
For cooling, this is expressed as EER, for heating as COP.
Nominal Efficiencies are used for systems above 12kW. It is
not possible to compare Nominal and Seasonal Efficiency
ratings due to the different calculation methods used.
Daikin UK Price List 2016
Contents
New for 2016
2
Split, Sky Air Heat Pumps
5
VRV
55
Ventilation
109
Heating
113
Refrigeration
159
Applied
167
Services & Training
189
Discount Rating
Please insert your discounts here and then refer to the colour tabs on the edge of each page for reference.
Split, Sky Air Heat Pumps
VRV
Ventilation
MY DISCOUNT
MY DISCOUNT
MY DISCOUNT
%
%
%
Heating
Refrigeration
Applied
MY DISCOUNT
MY DISCOUNT
MY DISCOUNT
%
%
%
Price List 2016
1
New for 2016
FOR EASY ACCESS TO ALL DAIKIN UK CATALOGUES,
DATASHEETS, INSTALLATION AND OPERATION
MANUALS, LOG INTO THE NEW DAIKIN BUSINESS
PORTAL FROM 1 APRIL 2016: MY.DAIKIN.CO.UK
BOOK TRAINING NOW AT
WWW.DAIKINTRAINING.CO.UK
Daikin extends R32 range even
further to include more Splits and
Sky Air cassette
UPDATE
FOR 2016
Our range of split and Sky Air systems using
the next generation of refrigerants offers:
> Lower global warming potential
> Higher efficiencies
> Lower refrigerant charge
Total range now available:
> Ururu Sahara
> Emura
> FTXM High Inverter
> Multi units
> Duct for multi applications (FDXM-F)
> Sky Air Smart HiCOP Cassette
Page 6 - 11
Daikin unique Under Ceiling Cassette is
now available for connection to Classic
Allows even more applications to be served by this truly unique
product ideal for solid ceilings
Page 33
BRC1E53A controller for duty rotation
NEW
FOR 2016
Duty rotation standby and back-up for IT applications,
works with the new indoor units
> Wall mounted FAQ-C9
> Ceiling suspended FHQ-CB
Page 49
I
W I- F O L
TR
CO N A P P
V IA
Remote App control for VRV and Sky Air –
and an upgrade for the Split App
Ideal for customers who want remote control of their air
conditioning system, the VRV and Sky Air Wi-Fi adapter ensures
customers can return to the perfect environment.
For VRV and Sky Air
For Split
Page 105
2
Residential, Commercial and Industrial
Intelligent Tablet Controller – ideal for single and multistore retail estates or light commercial applications
Table
t
This cloud based control solution with remote access possibilities enables
access to fault controls, off-site control and energy management:
> Wi-Fi and cloud based control of SkyAir or VRV equipment
> Connects directly to Daikin DIII-Net protocol
> Single or Multi-site web interface
> Web based energy management system
Page 104
NEW
FOR 2016
Increased piping
limitations on VRV IV HR
> Indoor to indoor unit maximum
height difference has been
increased to 30m to give even
more system design flexibility
> Please ask you sales person to
undertake a selection
VRV IV Branch selector boxes with pre-fitted values
To further increase the flexibility of the BS boxes, we are now able to
offer the full range of multi BS boxes with valves pre fitted.
> The benefit of having valves pre-installed on the boxes saves
considerable time and effort on site
> NEW indoor units can be added without having to remove refrigerant
from the rest of the system, so you can avoid having to pump down /
vac out / recharge the whole system and save hours
when altering systems
Page 68
Page 97
Weather proof enclosures for VAM Total Heat Exchangers
If you need to install a VAM unit outside of a building, they need to be weatherproofed
as they are designed for installation internally.
We can offer fully weatherproofed housings for the VAM range which are rated IP46 to
make them suitable for outdoor installation. The VAM units are fitted into the enclosure
and delivered to site for fuss free installation.
Page 111
Daikin UK offer a customised service where
we can repaint units to any specified RAL
or BS finish
> C
ustomers sometimes require visible units to be less obtrusive,
whether for aesthetic or planning reasons or to meet a specific
colour requirement
> Available for VRV, Split, Sky Air and all other units as required
Page 41 / 69
Strip down and rebuild service – ask for your unit to be
dismantled and reassembled for installation in those difficult
to access locations
> Daikin engineers will strip down and package the unit, organise delivery to the kerb-side
> Daikin engineers will then attend site to rebuild, pressure test, and vacuum and charge
the unit ready for connection to the rest of the system
Page 69
Price List 2016
3
NEW
FOR 2016
Netatmo for domestic heating
The smart thermostat, available from January 2016,
gives homeowners with Daikin Altherma air-to-water
heat pumps the option to control their heating
temperature via a smartphone app.
Page 134
Industrial refrigeration condensing unit with screw compressor
> H
igh efficiency inverter controlled compressor, economiser and high performance condenser
> Easy to install , ready to connect evaporator
> Capacity up to 450 kW on MT and 170 kW LT (@+32°C)
Page 166
NEW
FOR 2016
>
>
>
>
Modular AHU with DX
or water packaged solution
igh efficiency fan motors (IE4) and heat recovery exchangers
H
Full VRV IV or ERQ condenser connection compatibility
Complete package with integrated controls
Monitoring and control through Daikin ITM
Modular Heat Wheel
Modular Plate
1200-1500m3/h1200-1500m3/h
April 16
Dec 16
NEW
FOR 2016
Aircooled DC inverter screw
series – Gen 2 TZ series
> Introduction of Microchannel coils as standard
> Compressors with DC electrical motor
& Gen 2 Variable Volume Ratio (VVR)
170-700kW 720-1100kW1130-1800kW
April 16
June 16
Sept 16
Page 186 - 188
NEW
FOR 2016
Watercooled inverter
screw series
> A
C Inverter driven screw compressors
> Market leading full and partload efficiency in its class
(best ESEER level)
450-1800kW
June 16
4
Residential, Commercial and Industrial
NEW
FOR 2016
BLDC high static ducted FCU
& controller
> C
ompletes BLDC range line-up – Low, Medium & High pressure
> Provides wider operating range per model at reduced noise levels
> NEW FWECSA controller with master/slave networking on RS485
450-1800kW
April 16
SPLIT, SKY AIR HEAT PUMPS
Daikin UK Price List 2016
Split, Sky Air Heat Pumps
Another First From Daikin: R326
R32 Wall Mounted Split Systems
7
R32 Multi Systems
10
R32 Sky Air Hi COP Cassette
11
Sky Air Roundflow Cassette12
Enhanced Capital Allowance (ECA) Scheme12
R410A Pair Applications13
Wall Mounted Split Systems
13
Floor Standing Split Systems
18
Ceiling Suspended Split Systems
24
Cassette Split Systems
28
Under Ceiling Cassette Split Systems
32
Ducted Split Systems
35
Multi Applications40
Multi Split Systems
40
Twin, Triple, Double Twin Systems
43
Infrastructure Cooling48
Sky Air – Duty Rotation
49
Air Curtains50
Central Ducted52
Scottish
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Reasons for change
Daikin products using R32
There are a number of options for the next generation refrigerant
gas, to meet future legislation and reduce the environmental
impact of air conditioning, heat pumps and refrigeration. The
choices are generally accepted to be R32, R410A, HFO blends, CO2,
and hydrocarbons, including R290 and R600.
The 2016 line-up of R32 products has 4 types of split systems.
Three are wall mounts, including a brand new FTXM with SEER
efficiencies of up to 8.53. We also include a Roundflow cassette:
the FCAHG.
Daikin’s work with R32
Because of its superior energy efficiency and low GWP, R32 is
Daikin’s preferred next generation refrigerant for air conditioners
and heat pumps. Its first domestic air conditioners using R32 were
introduced to Japan in 2012 and there have been sales in excess of
4 million systems since then.
Ururu Sarara (FTXZ)
R32 in brief
Wall mount (FTXM)
Roundflow Cassette (FCAHG)
Emura (FTXJ)
R32 is already used in HVAC equipment, as it makes up 50% of
R410A. It has a global warming potential (GWP) of 675, which is one
third that of R410A (2,088).
It’s more energy efficient, resulting in a lower refrigerant charge
and offering the potential to manufacture smaller units. As a single
component refrigerant, it is also easier to reuse and recycle. Like many
low GWP refrigerants, R32 is mildly flammable, requiring some new
tools and procedures during installation. It is also easier to handle
because it doesn’t fractionate when being charged as a vapour.
Daikin now also offer a multi-system on R32 for up to five indoor
units. These are connectable to the Emura, FTXM or new slim
Ducted R32 multi-fancoil:
>
>
>
>
Ururu Sarara (FTXZ) – see page 7
Emura (FTXJ) – see page 8
Wall mount (FTXM) – see page 9
Roundflow Cassette (FCAHG) – see page 11
Installation and equipment
Installation of R32 systems is very similar to R410A systems,
although slightly different equipment is required. These include:
Using R32 in a split system delivers:
> Lower GWP
> Higher efficiencies
> Smaller refrigerant charge
> Gauge manifold
> Recovery pump
> Electronic leak tester
These are available from a number of key manufacturers.
Please contact your local stockist.
Refrigerant performance
Refrigerant Charge
SPLIT, SKY AIR HEAT PUMPS
Another First From Daikin: R32
1.6
1.2
R22
Tooling
R410A
R32
Manifold
Scale
Vacuum pump
Leak detector
Recovery unit
Ventilation *
Warnings
Recovery bottle
Current tool
Current
Current
Current
Current
Recommended
Blue marks
40 bar, right thread
Different scale
Current
Current
Different
Different
Necessary (fan)
Blue+Red marks (p16)
48 bar, left thread
* when installed in a plant room
0.8
R-410A
R32
0.4
0
2.5
3.0
3.5
Energy Efficiency Ratio
6
Refrigerant
GWP
R22
R410A
R32
1,910
2,088
675
Residential, Commercial and Industrial
Based on 3.5kW Wall Mount
Contact Daikin Training to arrange an
R32 Training Course covering:
> Daikin’s range of R32 equipment
> Installation, equipment & handing of R32
www.daikintraining.co.uk
SPLIT, SKY AIR HEAT PUMPS
FTXZ-N / RXZ-N
Wall Mounted Ururu Sarara (with R32 refrigerant)
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low / S Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low / S Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
FTXZ25N
FTXZ35N
FTXZ50N
2.79
2.39
2.50
3.60
A+++
2.50
9.54
92
A+++
3.50
5.90
831
6.10 / 5.80
A/A
205
0.180 / 0.125 / 0.090 / 0.067
3.90
2.88
3.50
5.00
A+++
3.50
9.00
136
A+++
4.50
5.73
1100
5.30 / 5.00
A/A
330
0.200 / 0.140 / 0.090 / 0.067
295
798
372
15
42 / 35 / 27 / 19
57
5.58
3.77
5.00
6.30
A+++
5.00
8.60
203
A+++
5.60
5.50
1427
4.55 / 4.47
A/A
550
0.250 / 0.153 / 0.110 / 0.077
RXZ35N
RXZ50N
15
38 / 33 / 26 / 19
54
RXZ25N
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Holding Charge
Sound Pressure (Cooling) High
Sound Power
Air Flow Rate
High
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches (mm)
m
m
m
kg
dBA
dBA
m3/sec
1.80
2.8
16
1/4 (6.4) / 3/8 (9.5)
10
8
10
1.34
46
59
0.516
15
47 / 38 / 30 / 23
60
693 x 795 x 300
50kg
1ph
2.80
4.4
16
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
10
8
10
1.34
48
61
0.573
4.80
6.2
16
1/4 (6.4) / 3/8 (9.5)
10
8
10
1.34
49
63
0.673
●
●
●
£345.00
£938.00
£1,283.00
£405.00
£1,085.00
£1,490.00
£531.00
£1,142.00
£1,673.00
FTXZ / RXZ systems use R32 refrigerant
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRP069A42
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
KPMH974A42
KPMH974A402
KPMJ942A4
KPMJ983A4L
KPMH950A4L
K.CWB90-2
K.DT1
Wi-fi adaptor to connection on on-line controller
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Hose for humidification (10m length)
Humidification hose extension set (2m length)
Humidification hose extension joints (10 pieces)
L-shaped joints for humidification hose (10 pieces)
L-shaped cuffs for humidification hose (10 pieces)
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
£50.00
£75.00
£132.00
£164.00
£151.00
£138.00
£52.00
£36.00
£104.00
£36.00
£37.00
£54.00
i)All fan coils supplied with infrared
remote control ARC477A1
ii)The supplied humidifying hose is 8m
in length
iii)Minimum ambient operating
temperatures:
RXZ
Cooling
Heating
-10°C
-20°C
Features:
> Complete climate control withe dehumidification, ventilation, air purification and heating & cooling in ONE system
> Very high efficiency solution, thanks to Ururu technology & R32 refrigerant
> Self cleaning filters ensure optimum air quality & efficiency of operation
> Infrared remote controller with backlit display, or optional Online Control via smartphone or tablet
>3 area intelligent eye ensures air is directed away from people in the room, and switches unit to energy-efficient mode
if no-one is detected
I
W I- F O L
TR
CO N A P P
V IA
Price List 2016
7
SPLIT, SKY AIR HEAT PUMPS
FTXJ-MW/S / RXJ-M
Wall Mounted – Emura (with R32 refrigerant)
Indoor Units
Matt Crystal White
FTXJ20MW
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low / Silent
kW
kW
kW
kW
Height
Width
Depth
mm
mm
mm
kg
dBA
dBA
High / Low / Silent
Cooling
kW
kWh
kW
kWh
kWh
m3/sec
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Air Flow Rate (cooling)
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High / Silent
High
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
m3/Sec
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
FTXJ35MW
2.25
2.35
3.42
1.84
1.88
2.51
2.00
2.50
3.50
2.50
3.40
4.00
A+++
A+++
A++
2.30
2.40
3.50
8.73
8.64
7.19
92
97
170
A++
A++
A++
2.10
2.70
3.00
4.60
4.60
4.60
638
822
913
A/A
A/A
A/A
4.64 / 5.00
4.73 / 4.57
4.09 / 4.04
248
254
428
0.148 / 0.0073 / 0.148 / 0.0073 / 0.182 / 0.080 /
0.043
0.043
0.048
303
998
212
12
12
12
38 / 25 / 19
38 / 25 / 19
45 / 26 / 20
54
54
59
RXJ20M
Height x Width x Depth
FTXJ25MW
2.67
2.6
10
1/4 / 3/8
20
15
10
0.72
46 / 43
61
0.575
RXJ25M
RXJ35M
550 x 765 x 285
34
1ph
2.82
4.18
3.6
4.6
10
10
3+E / 1.5
1/4 / 3/8
1/4 / 3/8
20
20
15
15
10
10
20
0.72
0.72
46 / 43
48 / 45
61
63
0.575
0.616
Brushed Aluminium
FTXJ50MW
FTXJ20MS
FTXJ25MS
FTXJ35MS
4.69
2.25
2.35
3.42
3.09
1.84
1.88
2.51
5.00
2.00
2.50
3.50
5.80
2.50
3.40
4.00
A++
A+++
A+++
A++
4.80
2.30
2.40
3.50
7.02
8.73
8.64
7.19
239
92
97
170
A+
A++
A++
A++
4.60
2.10
2.70
3.00
4.28
4.60
4.60
4.60
1505
638
822
913
A/A
A/A
A/A
A/A
3.35 / 3.65
4.64 / 5.00
4.73 / 4.57
4.09 / 4.04
716
248
254
428
0.182 / 0.113 / 0.148 / 0.0073 / 0.148 / 0.0073 / 0.182 / 0.080 /
0.060
0.043
0.043
0.048
303
998
212
12
12
12
12
45 / 35 / 32
38 / 25 / 19
38 / 25 / 19
45 / 26 / 20
60
54
54
59
RXJ50M
RXJ20M
735 x 825 x 315
47
6.43
6.9
15
2.67
2.6
10
1/4 / 1/2
30
20
10
1/4 / 3/8
20
15
10
1.3
48 / 45
63
0.830
0.72
46 / 43
61
0.575
RXJ25M
FTXJ50MS
4.69
3.09
5.00
5.80
A++
4.80
7.02
239
A+
4.60
4.28
1505
A/A
3.35 / 3.65
716
0.182 / 0.113 /
0.060
12
45 / 35 / 32
60
RXJ35M
550 x 765 x 300
34
1ph
2.82
4.18
3.6
4.6
10
10
3+E / 1.5
1/4 / 3/8
1/4 / 3/8
20
20
15
15
10
10
20
0.72
0.72
46 / 43
48 / 45
61
63
0.575
0.616
RXJ50M
735 x 825 x 315
48
6.43
6.9
15
1/4 / 1/2
30
20
10
1.1
48 / 45
63
0.830
●
●
●
●
●
●
●
●
£276.00
£502.00
£778.00
£290.00
£530.00
£820.00
£326.00
£615.00
£941.00
£430.00
£829.00
£1,259.00
£329.00
£502.00
£831.00
£346.00
£530.00
£876.00
£388.00
£615.00
£1,003.00
£513.00
£829.00
£1,342.00
FTXJ / RXJ systems use R32, for R410A version see page 13
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC073
BRCW901A03
BRCW901A08
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
K.CWB90-2
K.DT1
K.CGS
K.CGM
Optional Wired Remote controller: BRC1E52 style
3m connection cable for BRC073
8m connection cable for BRC073
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£80.00
£17.00
£22.00
£75.00
£132.00
£164.00
£151.00
£37.00
£54.00
£214.00
£296.00
i)All fan coil units standard with auto restart
after power failure
ii)All fan coils supplied as standard with
infrared remote controller ARC466A1
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Minimum ambient operating
temperatures:
RXJ
Features:
> Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round
> It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling
> Stylish, low-profile design
>Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming.
Up to 4 actions per day possible
> Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
>NEW Improved titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
> 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment
> Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins
> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
> Fan speed: 5 fan speeds can be selected, high to super low
8
Residential, Commercial and Industrial
Cooling
Heating
-10°C
-15°C
I
W I- F O L
TR
CO N A P P
V IA
WI-FI ADAPTOR
NOW INCLUDED
AS STANDARD
SPLIT, SKY AIR HEAT PUMPS
FTXM-M / RXM-M
Wall Mounted – Standard Inverter (with R32 refrigerant)
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low / Silent
kW
kW
kW
kW
Height
Width
Depth
mm
mm
mm
kg
dBA
dBA
High / Low / Silent
kW
kWh
kW
kWh
kWh
m3/sec
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Air Flow Rate (Cooling)
FTXM20M
FTXM25M
FTXM35M
FTXM42M
FTXM50M
FTXM60M
FTXM71M
1.95
1.65
2.00
2.50
A+++
2.00
8.53
83
A+++
2.30
5.10
632
A/A
4.57 / 5.00
219
0.185 / 0.100 /
0.073
272
811
294
10
41 / 25 / 19
57
2.44
1.82
2.50
3.40
A+++
2.50
8.52
103
A+++
2.40
5.10
659
A/A
4.50 / 5.00
278
0.185 / 0.103 /
0.073
272
811
294
10
41 / 25 / 19
57
3.42
2.56
3.50
4.00
A+++
3.40
8.51
140
A+++
2.50
5.10
686
A/A
4.23 / 4.04
402
0.210 / 0.106 /
0.076
272
811
294
10
45 / 29 / 19
60
4.11
2.85
4.20
5.40
A++
4.20
7.50
196
A++
4.00
4.60
1217
A/A
3.75 / 4.12
560
0.210 / 0.118 /
0.076
272
811
294
10
45 / 30 / 21
60
4.56
3.14
5.00
5.80
A++
5.00
7.33
239
A++
4.60
4.60
1400
A/A
3.68 / 4.00
682
0.266 / 0.185 /
0.168
TBC
TBC
6.0
7.0
A++
6
6.9
304
A+
4.6
TBC
1498
A/A
3.39 / 3.61
885
- / 0.318 / -
TBC
TBC
7.1
8.2
A++
6.8
6.11
390
A
6.2
TBC
2278
B/D
3.03 / 3.19
1174
- / 0.341 / -
46 / 37 / 34
60
295
1040
300
14.5
TBC
61
TBC
62
RXM25M
RXM35M
RXM42M
RXM50M
RXM60M
RXM71M
44
735 x 870 x 320
44
RXM20M
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High / Silent
High
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
m3/sec
0.76
46 / 59
0.600
550 x 765 x 285
32
1ph
2.47
3.7
10
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
15
10
20
0.76
46 / 59
0.600
●
£162.00
£458.00
£620.00
32
1.95
3.7
10
20
15
10
735 x 825 x 300
44
1ph
6.48
6.6
20
3+E / 2.5
1/4 (6.4) / 1/2 (12.7)
30
15
10
20
1.4
48 / 44
63
0.840
32
44
4.23
4.4
10
4.97
6.8
20
20
15
10
30
15
10
0.76
49 / 61
0.600
1.30
48 / 44
63
0.848
●
●
●
£173.00
£500.00
£673.00
£198.00
£581.00
£779.00
£223.00
£655.00
£878.00
TBC
TBC
TBC
TBC
30
15
10
TBC
TBC
TBC
TBC
TBC
30
15
10
1.5
48 / 44
63
TBC
1.7
47 / 66
TBC
●
●
●
£309.00
£730.00
£1,039.00
£315.00
£777.00
£1,092.00
£420.00
£1,064.00
£1,484.00
FTXM / RXM systems use R32, for R410A version see page 14
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC073
BRP069A42
BRCW901A03
BRCW901A08
KRP928A2S
KLIC-DD
RTD-RA
K.CWB90-2
K.DT1
K.DT2
K.CGS
K.CGM
Optional Wired Remote controller: BRC1E52 style
Wifi adaptor for connection to on-line controller
3m connection cable for BRC073
8m connection cable for BRC073
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£80.00
£50.00
£17.00
£22.00
£132.00
£164.00
£151.00
£37.00
£54.00
£59.00
£214.00
£296.00
i)All fan coil units standard with auto restart
after power failure
ii)All fan coils supplied as standard with
infrared remote controller
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Minimum ambient operating
temperatures:
RXM
Cooling
Heating
-10°C
-15°C
Features:
> Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming.
Up to 4 actions per day possible
> Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
> NEW Air purification using Flash Streamer technology to remove odour & bacteria
> 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment
> Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins
> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
> Fan speed: 5 fan speeds can be selected, high to super low
I
W I- F O L
TR
CO N A P P
V IA
Price List 2016
9
SPLIT, SKY AIR HEAT PUMPS
I
W I- F O L
TR
CO N A P P
V IA
Multi Series
Multi Series Inverters offer the ability to connect up to five fan coils to one
outdoor unit. With the MXS range it is possible to install indoor units throughout
a house or small commercial premises and only use one outdoor unit. Each indoor
unit will have it’s own controller and will be able to operate in heating or cooling.
Outdoor unit
*2MXM40M *2MXM50M *3MXM40M *3MXM52M *3MXM68M *4MXM68M *4MXM80M *5MXM90M
Dimensions
Weight
Sound power level
Sound pressure level
Unit
HeightxWidthxDepth
Unit
Cooling
Cooling
Nom.
Heating
Nom.
Power supply
Phase / Frequency / Voltage
Operation range
Cooling
Ambient
Min.~Max.
Heating
Ambient
Min.~Max.
Number of connected indoor units
mm
kg
dBA
dBA
dBA
Hz / V
°CDB
°CWB
550x765x285
735x870x320
-
60
46
48
Trade Condensing Unit Price
61
48
50
59
46
47
2
2
3
£1,048.00
£1,159.00
£1,092.00
61
62
48
1~ / 50 / 220-240
-10~46
-15~24
3
3
£1,214.00
49
£1,719.00
4
4
5
£1,854.00
£2,088.00
£2,248.00
Wall mounted
*Daikin Emura FTXJ-MW/S
Connectable
indoor units
2MXM40M
2MXM50M
3MXM40M
3MXM52M
3MXM68M
4MXM68M
4MXM80M
5MXM90M
20
25
35
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Concealed ceiling
*FDXM-F
*FTXM-M
50
l
20
25
35
l
l
l
42
l
66
52
52
48
50
60
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
71
l
25
35
l
l
50
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
l
* preliminary data
Daikin’s new Multi Selection Tool is a fast and simple way to select your combinations for MXS Series outdoor units.
The online tool has four simple steps:
> select number of rooms
> select capacity per room
> select capacity of outdoor
> select type of indoor & input pipe run & level difference
It has in-built checks to ensure capacity, pipe length and level difference cannot exceed maximum for selected outdoor
unit and generates a report showing full energy label for specific combination and pictures of all equipment selected.
This can be used by installers to select Multi systems, and also to show end-users the configuration of the system.
Go to www.daikineurope.com/multiselection
Multi Split & Mini VRV Fan Coils
R32 Emura Wall Mounted Fan Coil Units
Trade Fan Coil Unit Price
FTXJ20MW FTXJ25MW FTXJ35MW FTXJ50MW FTXJ20MS FTXJ25MS FTXJ35MS FTXJ50MS
£276.00
£290.00
£326.00
£430.00
£329.00
£346.00
£388.00
£513.00
R32 Wall Mounted Fan Coil Units
Trade Fan Coil Unit Price
FTXM20M FTXM25M FTXM35M FTXM42M FTXM50M FTXM60M FTXM71M
£162.00
£173.00
£198.00
£223.00
£309.00
£315.00
£420.00
R32 Slim Ducted Fan Coil Units
Trade Fan Coil Unit Price
FDXM25F
£334.00
FDXM35F
£383.00
FDXM50F
£421.00
FDXM60F
£470.00
Slim Ducted – for use with R32 Multi
Indoor unit
Dimensions
Weight
Air filter
Fan - Air flow rate
Unit
HeightxWidthxDepth
Unit
Type
Cooling
High/Nom./Low
Heating
High/Nom./Low
Fan - External static pressure
Nom./Maximum available/High
Sound power level
Cooling
Heating
Sound pressure level Cooling
High/Nom./Low
Heating
High/Nom./Low
Power supply
Phase / Frequency / Voltage
Control systems
Infrared remote control
Wired remote control
* preliminary data
10
Residential, Commercial and Industrial
FDXM
mm
kg
m³/min
m³/min
Pa
dBA
dBA
dBA
dBA
Hz / V
*25F
*35F
*50F
*60F
200x750x620
21
8.7/8.0/7.3
8.7/8.0/7.3
30/-
200x1,150x620
30
Removable / washable / mildew proof
12.0/11.0/10.0
16.0/14.8/13.5
16.0/14.8/13.5
40/-
53
53
35/33/27
35/33/27
1~ / 50 / 230
55
55
38/36/30
56
56
38/35/30
38/36/30
1~ / 50 / 220-240
BRC4C65
BRC1E52
60
SPLIT, SKY AIR HEAT PUMPS
FCAHG-F / RZAG-L
High COP Roundflow Cassette – Seasonal Smart (R32)
Indoor Units
Single Phase
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Air Flow Rate (cooling)
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Nom
Nom
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
FCAHG71F
FCAHG100F
FCAHG125F
FCAHG140F
7.76
5.32
6.80
7.50
A++
6.80
7.35
TBC
A+
7.60
4.54
2343
A/A
4.09 / 4.80
831
0.353 / 0.270 / 0.203
288(348)
840 (950)
840 (950)
25 (30.5)
36 / 33 / 29
53
10.80
7.44
9.50
10.80
A++
9.50
7.35
TBC
A++
11.30
4.80
3298
A/A
4.42 / 4.99
1075
0.538 / 0.428 / 0.317
288 (348)
840 (950)
840 (950)
26 (31.4)
44 / 39 / 33
61
13.60
9.30
12.00
13.50
A++
12.0
6.94
TBC
A++
12.66
4.63
3829
A/A
4.00 / 4.00
1500
0.558 / 0.445 / 0.332
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 40 / 35
61
14.90
10.25
13.40
15.50
A/A
3.35 / 4.12
2000
0.558 / 0.455 / 0.352
288 (348)
840 (950)
840 (950)
26 (31.4)
45 / 41 / 37
61
RZAG71LV1
RZAG100LV1
RZAG125LV1
RZAG140LV1
95
1430 x 940 x 320
95
95
TBC
4
32
TBC
4
32
75
30
30
75
30
30
990 x 940 x 320
69
1ph
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
m3/sec
TBC
4
20
TBC
4
32
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
30
30
75
30
30
2.6
48
64
TBC
3.6
50
66
TBC
3.6
51
67
TBC
3.6
52
69
TBC
£815.00
£1,251.00
£2,066.00
£924.00
£1,590.00
£2,514.00
£1,010.00
£1,749.00
£2,759.00
£1,216.00
£1,996.00
£3,212.00
Refer to Installation Manual
FCAHG / RZAG systems use R32, for R410A version see page 28
Accessories:
Accessory Ref
BRC7FA532F
BYCQ140DG
BYCQ140DW
BRYQ140A
KDBHQ55B140
KDDQ55B140 1&2
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
Notes:
Description
Wireless remote controller
Roundflow cassette decoration panel with self cleaning filter
Roundflow cassette decoration panel - white with white louvres
Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions
Sealing member for air discharge outlet
Fresh air intake kit for up to 20% fresh air - 2 part kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
Trade Price
£152.00
£310.00
£160.00
£99.00
£90.00
£233.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£46.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7FA532F Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto
restart after power failure
iv)All fan coils suppled as standard with
BYCQ140D Decoration panel
v)BYCQ140DW / BYCQ140DG Trade prices
will be reduced by £142.00 if ordered in
place of standard decoration panel
vi)Minimum ambient operating
temperatures:
RZAG
Cooling
Heating
-15°C
-20°C
Features:
> The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market
> The unique 360° radial air pattern ensures uniform air flow and temperature distribution
> Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller
> Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
>Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost
> Optional Fresh Air intake (up to 20%) possible
> Re-use of existing R22 and R407C piping possible
> Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)
> DIII net compatibility as standard
Price List 2016
11
SPLIT, SKY AIR HEAT PUMPS
Sky Air Exclusive to Wholesale
One brand, 3 options:
Daikin has a solution for all
your needs:
> Price
> Performance
> Highest Efficiency
>
>
>
>
>
>
Pair applications
30m pipe run
-5 / -15°C operating range in cooling / heating
A/A Energy Labels
R22 replacement technology
Single fan outdoor up to 12kW
>
>
>
>
>
Pair, twin, triple, double twin applications
50m pipe run
-15 / -15°C operating range in cooling / heating
A+/A+ Energy Labels
R22 replacement technology
>
>
>
>
>
>
Pair, twin, triple, double twin applications
75m pipe run
-15 / -20°C operating range in cooling / heating
Up to A++/A+ Energy Labels
All capacities ECA Eligible
R22 replacement technology
Enhanced Capital Allowance (ECA) Scheme
The Enhanced Capital Allowance (ECA)
scheme provides businesses with enhanced
tax relief for investment in energy-saving
equipment that meets specified Government
criteria. It allows 100% of the investment to
be written off against taxable profit in the
year the investment is made.
The Energy Technology List (ETL) is a definitive
list of all the products that qualify for the ECA,
typically by meeting or exceeding efficiency
standards. For DX, the list covers approximately
the top 20% of air conditioning systems and is
updated regularly to ensure that it includes the
most energy efficient products currently available.
Daikin now has a website that allows customers to check whether
selected equipment is efficient enough to be eligible to claim
Enhanced Capital Allowances.
Go to www.daikin.co.uk/eca to check:
> Split
> Sky Air
> VRV
The website also allows you to
create a Certificate of Eligibility
for your equipment selection
that can be used to support a
claim for ECA.
Certain types of equipment are listed on the ECA website.
To check eligibility of the following equipment types,
please go to www.etl.decc.gov.uk/etl/site.htm
> Biddle Air Curtains (Split and VRV)
> Ventilation (VAMs)
> Control Options (RTD20)
> Chillers
The ETL website should also be used
to check equipment eligibility for Split,
Sky Air & VRV equipment purchased
before August 2014.
12
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
FTXG-LW/S / RXG-L
Wall Mounted – Emura
Indoor Units
Matt Crystal White
FTXG20LW
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low / Silent
kW
kW
kW
kW
Height
Width
Depth
mm
mm
mm
kg
dBA
dBA
Weight
Sound Pressure (Cooling) High / Low / Silent
Sound Power
kW
kWh
kW
kWh
kWh
m3/sec
Outdoor Units
Dimensions
Weight
Electrical Details
2.25
1.84
2.00
2.50
A+++
2.30
8.52
94
A++
2.10
4.60
639
4.59 / 5
A/A
250
0.148 / 0.073 /
0.043
12
38 / 25 / 19
54
RXG20L
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring
Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate
High
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
2.70
2.8
16
20
15
10
1.05
46 / 43
61
0.575
FTXG25LW
FTXG35LW
2.35
3.42
1.88
2.51
2.50
3.50
3.40
4.00
A+++
A++
2.40
3.50
8.50
7.00
99
175
A++
A++
2.70
3.00
4.60
4.60
821
913
4.59 / 4.42
3.97 / 4.06
A/A
A/A
261
441
0.148 / 0.073 / 0.182 / 0.080 /
0.043
0.048
303
998
212
12
12
38 / 25 / 19
45 / 26 / 20
54
59
RXG25L
RXG35L
550 x 765 x 285
35
1ph
2.80
4.80
4.4
5.5
16
16
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
20
15
15
10
10
20
1.05
1.05
46 / 43
48 / 44
61
63
0.575
0.616
Silver
FTXG50LW
FTXG20LS
4.69
3.09
5.00
5.80
A++
4.80
6.70
251
A+
4.60
4.24
1519
3.53 / 3.65
A/A
680
0.182 / 0.113 /
0.060
2.25
1.84
2.00
2.50
A+++
2.30
8.52
94
A++
2.10
4.60
639
4.59 / 5
A/A
250
0.148 / 0.073 /
0.043
12
46 / 35 / 32
60
12
38 / 25 / 19
54
RXG50L
RXG20L
735 x 825 x 300
48
6.20
7.4
20
2.70
2.8
16
1/4 (6.4) / 1/2 (12.7)
30
20
10
20
15
10
1.6
48 / 44
63
0.830
1.05
46 / 43
61
0.575
FTXG25LS
FTXG35LS
2.35
3.42
1.88
2.51
2.50
3.50
3.40
4.00
A+++
A++
2.40
3.50
8.50
7.00
99
175
A++
A++
2.70
3.00
4.60
4.60
821
913
4.59 / 4.42
3.97 / 4.06
A/A
A/A
261
441
0.148 / 0.073 / 0.182 / 0.080 /
0.043
0.048
303
998
212
12
12
38 / 25 / 19
45 / 26 / 20
54
59
RXG25L
FTXG50LS
4.69
3.09
5.00
5.80
A++
4.80
6.70
251
A+
4.60
4.24
1519
3.53 / 3.65
A/A
680
0.182 / 0.113 /
0.060
12
46 / 35 / 32
60
RXG35L
RXG50L
550 x 765 x 285
35
1ph
2.80
4.80
4.4
5.5
16
16
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
20
15
15
10
10
20
1.05
1.05
46 / 43
48 / 44
61
63
0.575
0.616
735 x 825 x 300
48
6.20
7.4
20
1/4 (6.4) / 1/2 (12.7)
30
20
10
1.6
48 / 44
63
0.830
●
●
●
●
●
●
●
●
£262.00
£478.00
£740.00
£276.00
£504.00
£780.00
£310.00
£585.00
£895.00
£409.00
£789.00
£1,198.00
£313.00
£478.00
£791.00
£329.00
£504.00
£833.00
£369.00
£585.00
£954.00
£488.00
£789.00
£1,277.00
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC073
BRCW901A03
BRCW901A08
BRP069A41
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
K.CWB90-2
K.DT1
K.CGS
K.CGM
Optional Wired Remote controller: BRC1E52 style
3m connection cable for BRC073
8m connection cable for BRC073
Wifi adaptor for connection to on-line controller
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£80.00
£17.00
£22.00
£40.00
£75.00
£132.00
£164.00
£151.00
£37.00
£54.00
£214.00
£296.00
i)All fan coil units standard with auto restart
after power failure
ii)All fan coils supplied as standard with
infrared remote controller ARC466A1
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Control option is either hard-wired
remote, or Wi-Fi adaptor
v)Minimum ambient operating
temperatures:
RXG
Cooling
Heating
-10°C
-15°C
Features:
> Designed in Europe, perfect for UK climates, Daikin Emura creates the optimum comfort zone all year round
> It represents a perfect marriage of style and substance, of form and function, of intelligent heating and efficient cooling
> Stylish, low-profile design
>Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming.
Up to 4 actions per day possible
> Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
> 2-area intelligent eye: air flow is sent to a zone other than where the occupants are located at that moment
> Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins
> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
> Fan speed: 5 fan speeds can be selected, high to super low
> Suitable for multi model applications
> Re-use of existing R22 and R407C piping possible
I
W I- F O L
TR
CO N A P P
V IA
Price List 2016
13
SPLIT, SKY AIR HEAT PUMPS
FTXS-K/G / RXS-L/F
Wall Mounted – Standard Inverter
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low / Silent
kW
kW
kW
kW
Height
Width
Depth
mm
mm
mm
kg
dBA
dBA
Weight
Sound Pressure (Cooling) High / Nom / Low / Silent
Sound Power
kW
kWh
kW
kWh
kWh
m3/sec
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate (Cooling)
High
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
FTXS-K series
FTXS-G series
FTXS20K
FTXS25K
FTXS35K
FTXS42K
FTXS50K
FTXS60G
FTXS71G
1.95
1.65
2.00
2.50
A++
2.00
7.40
95
A++
2.30
4.77
675
4.65 / 4.72
A/A
228
0.147 / 0.078 /
0.065
289
780
215
8
40 / 32 / 24 / 19
58
2.44
1.82
2.50
3.40
A++
2.50
7.90
111
A++
2.50
4.78
732
4.21 / 4.67
A/A
297
0.152 / 0.083 /
0.065
289
780
215
8
41 / 33 / 25 / 19
58
3.42
2.56
3.50
4.00
A++
3.50
7.47
164
A++
3.50
4.85
1039
3.89 / 4.76
A/A
450
0.187 / 0.097 /
0.068
298
900
215
11
45 / 37 / 29 / 19
59
4.11
2.85
4.20
5.40
A++
4.20
6.80
216
A+
4.00
4.20
1334
3.35 / 4.12
A/A
627
0.187 / 0.117 /
0.068
298
900
215
11
45 / 39 / 33 / 21
59
4.56
3.14
5.00
5.80
A++
5.00
6.80
257
A+
4.60
4.20
1535
3.32 / 4
A/A
753
0.198 / 0.123 /
0.075
298
900
215
11
46 / 40 / 34 / 23
60
5.86
3.87
6.00
7.00
A
6.00
5.58
376
A
4.80
3.89
1728
3.02 / 3.43
B/B
995
0.267 / 0.188 /
0.168
290
1050
250
12
45 / 41 / 36 / 33
60
6.94
4.65
7.10
8.20
A
7.10
5.23
475
A
6.50
3.50
2593
3.02 / 3.22
B/C
1175
0.287 / 0.192 /
0.175
290
1050
250
12
46 / 42 / 37 / 34
63
RXS20L3
RXS25L3
RXS35L3
RXS42L
RXS50L
RXS60L
550 x 765 x 285
34
2.30
2.4
10
20
15
10
1.0
46 / 43
59
0.558
550 x 765 x 285
34
1ph
3.10
3.3
10
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
15
10
20
1.0
46 / 43
59
0.558
34
735 x 825 x 300
39
47
RXS71F8
48
770 x 900 x 320
71
8.80
9.4
20
10.49
11.7
20
1ph
4.10
4.3
10
5.70
6.6
20
20
15
10
20
15
10
1.2
48 / 44
61
0.600
1.3
48 / 44
61
0.621
6.30
6.8
20
3+E / 1.5
1/4 (6.4) / 1/2 (12.7)
30
30
20
20
10
10
20
1.7
1.5
48 / 44
49 / 46
62
62
0.848
0.835
●
●
●
●
●
£154.00
£436.00
£590.00
£165.00
£476.00
£641.00
£189.00
£552.00
£741.00
£212.00
£623.00
£835.00
£294.00
£694.00
£988.00
Accessories:
£300.00
£740.00
£1,040.00
1/4 (6.4) / 5/8 (15.9)
30
20
10
2.3
52 / 49
65
0.910
£400.00
£1,013.00
£1,413.00
Notes:
Accessory Ref
Description
Trade Price
KRP980A1
BRC073
BRP069A42
BRCW901A03
BRCW901A08
KRP928A2S
KLIC-DD
RTD-RA
K.CWB90-2
K.DT1
K.DT2
K.CGS
K.CGM
S21 adaptor for FTXS20K & 25K for ALL control options
Optional Wired Remote controller: BRC1E52 style
Wifi adaptor for connection to on-line controller
3m connection cable for BRC073
8m connection cable for BRC073
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£50.00
£80.00
£50.00
£17.00
£22.00
£132.00
£164.00
£151.00
£37.00
£54.00
£59.00
£214.00
£296.00
i)All fan coil units standard with auto restart
after power failure
ii)All fan coils supplied as standard with
infrared remote controller
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Control option is either hard-wired
remote, or Wi-Fi adaptor
v)FTXS-K and FTXS-G have different
style casing
vi)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
> Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming.
Up to 4 actions per day possible
> Night set mode: prevents sudden changes in room temperature by gently adjusting the temperature before the system stops
> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
> 2-area intelligent eye: (35~50 K class) air flow is sent to a zone other than where the occupants are located at that moment
> Presence Sensor switches to energy saving mode if room is unoccupied after 20 mins
> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
> Fan speed: 5 fan speeds can be selected, high to super low
> Suitable for multi model applications
> Re-use of existing R22 and R407C piping possible
14
Residential, Commercial and Industrial
I
W I- F O L
TR
CO N A P P
V IA
SPLIT, SKY AIR HEAT PUMPS
FTXB / RXB
Wall Mounted – Low Inverter
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low / Silent
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
FTXB50-60C
FTXB20C
FTXB25C
FTXB35C
FTXB50C
FTXB60C
1.96
1.66
2.00
2.50
A+
2.00
5.98
117
A+
2.20
4.10
751
3.94 / 4.19
A/A
254
9.1 / 5.9
2.44
1.78
2.50
2.80
A+
2.50
6.02
145
A+
2.40
4.01
838
3.25 / 4.01
A/A
385
9.2 / 6.0
283
770
216
8
40 / 26 / 21
55
3.07
2.11
3.30
4.80
A+
3.30
6.05
191
A+
2.80
4.06
966
3.32 / 3.71
A/A
514
9.3 / 6.1
4.80
3.19
5.48
5.62
A+
5.48
5.93
324
A+
3.64
4.27
1193
3.32 / 2.75
A/A
854
15.0 / 11.82
5.46
3.83
6.23
6.40
A+
6.23
6.09
359
A+
3.80
4.06
1310
3.23 / 3.81
A/A
964
18.5 / 14.3
41 / 27 / 21
58
44 / 38 / 32
55
46 / 43 / 37
61
RXB25C
RXB35C
RXB50C
RXB60C
39 / 25 / 21
55
RXB20C
Height x Width x Depth
FTXB20-35C
0.74
46
60
550 x 658 x 275
28
1ph
3.69
3.7
16
3+E / 1.5
1/4 / 3/8
15
12
10
Databook
0.74
46
60
£100.00
£298.00
£398.00
£107.00
£319.00
£426.00
28
2.34
3.0
16
1/4 / 3/8
15
12
10
310
1065
224
14
753 x 855 x 328
30
44
44
1ph
5.34
5.2
16
7.51*
tbc
20
8,52*
tbc
20
1/4 / 3/8
15
12
10
1/4 / 1/2
30
10
7.5
1.00
48
62
1.45
47
64
1.45
49
65
£124.00
£371.00
£495.00
£181.00
£465.00
£646.00
£214.00
£549.00
3+E / 2.5
1/4 / 5/8
30
10
7.5
Databook
Accessories:
£763.00
Notes:
Accessory Ref
Description
Trade Price
K.CWB90-2
K.DT1
K.CGS
K.CGM
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£37.00
£56.00
£214.00
£296.00
Features:
> Wireless remote controller with daily timer function
> Titanium Apatire photocatalytic air purifying filter: superior purification & deoderisation of air inside room
> Powerful operation: activates maximum air volume for 20 minutes
> Auto-swing mode for optimal air flow within the room
> Silent mode can reduce sound levels to 21dBA in the room
i)All fancoils supplied with infrared
remote controller
FTXB20/25/35 with ARC470A1
FTXB50 / 60 with APGS02
ii)All fancoil units standard with auto
restart after power failure
iii)Minimum ambient operating
temperatures:
RXB-C
Cooling
Heating
-10°C
-15°C
WHOLESALE
EXCLUSIVE
Price List 2016
15
SPLIT, SKY AIR HEAT PUMPS
FAQ-C9 / RZQG-L
Wall Mounted – Seasonal Smart
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
Nominal
mm
kg
3 Phase
FAQ71C9
FAQ100C9
FAQ71C9
FAQ100C9
7.76
5.32
6.80
7.50
A++
6.80
6.51
366
A+
6.33
4.02
2205
3.4 / 3.7
A/A
1000
0.300 / 0.267 / 0.233
290
1050
238
13
45 / 42 / 40
61
10.80
7.44
9.50
10.80
A++
9.50
6.11
545
A+
10.20
4.01
3562
3.62 / 3.61
A/A
1315
0.433 / 0.383 / 0.317
340
1200
240
17
49 / 45 / 41
65
7.76
5.32
6.80
7.50
A++
6.80
6.51
366
A+
6.33
4.02
2205
3.4 / 3.7
A/A
1000
0.300 / 0.267 / 0.233
290
1050
238
13
45 / 42 / 40
61
10.80
7.44
9.50
10.80
A++
9.50
6.11
545
A+
10.20
4.01
3562
3.62 / 3.61
A/A
1315
0.433 / 0.383 / 0.317
340
1200
240
17
49 / 45 / 41
65
RZQG71L9V1
RZQG100L9V1
RZQG71L8Y1
RZQG100L8Y1
990 x 940 x 320
69
1430 x 940 x 320
95
990 x 940 x 320
80
1430 x 940 x 320
101
10.75
4
32
3.07
4
16
1ph
A
A
A
8.17
4
20
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
ECA Eligible
3ph
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
30
30
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
75
30
30
50
30
30
Refer to Installation Manual
2.9
4.0
48 / 43
50 / 45
64
66
0.983
1.166
£749.00
£1,191.00
£1,940.00
75
30
30
Refer to Installation Manual
2.9
4.0
48 / 43
50 / 45
64
66
0.983
1.116
●
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
4.04
4
20
●
£808.00
£1,514.00
£2,322.00
£749.00
£1,227.00
£1,976.00
£808.00
£1,584.00
£2,392.00
For Comms Rooms & Duty Rotation see page 48 - 49
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC7EB518
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
Wireless remote controller
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£46.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7EB518 Trade price will be reduced by
£76.00 if ordered instead of the BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RZQG
RZQSG
Features:
> Fan speed: 3 fan speeds available on all capacities
> Automatic airflow volume control sets fan speed based on difference between set and room temperatures
> Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature
> Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
> Selectable evaporating & condensing temperature for greater operating efficiency and application flexibility (Seasonal Smart)
> DIII net compatibility as standard
> Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology
> Re-use of existing R22 and R407C piping possible. (See R22 Replacement leaflet)
> Suitable for Twin, Triple and Double Twin applications
16
Residential, Commercial and Industrial
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
FAQ-C9 / RZQSG-L
Wall Mounted – Seasonal Classic
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
Nominal
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
3 Phase
FAQ71C9
FAQ100C9
FAQ100C9
7.28
4.99
6.80
7.50
A+
6.80
6.05
393
A+
6.00
3.90
2155
3.21 / 3.61
A/A
1060
0.300 / 0.267 / 0.233
290
1050
238
13
45 / 42 / 40
61
10.80
7.44
9.50
10.80
A+
9.50
5.61
593
A+
6.81
4.01
2378
3.01 / 3.41
B/B
1580
0.433 / 0.383 / 0.317
340
1200
240
17
49 / 45 / 41
65
10.80
7.44
9.50
10.80
A+
9.50
5.61
593
A+
6.81
4.01
2378
3.01 / 3.41
B/B
1580
0.433 / 0.383 / 0.317
340
1200
240
17
49 / 45 / 41
65
RZQSG71L3V1
RZQSG100L9V1
RZQSG100L8Y1
770 x 900 x 320
67
990 x 940 x 320
72
2.75
49 / 49
65
0.866
2.9
53 / 49
70
1.266
990 x 940 x 320
82
3ph
4.86
4
20
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
30
30
Refer to Installation Manual
2.9
53 / 49
70
1.266
£749.00
£820.00
£1,569.00
£808.00
£1,135.00
£1,943.00
£808.00
£1,170.00
£1,978.00
1ph
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
8.66
4
20
12.91
4
32
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
15
30
50
30
30
Refer to Installation Manual
Price List 2016
17
SPLIT, SKY AIR HEAT PUMPS
FVXG-K / RXG-L
Stylish Floor Standing Cased – Nexura
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low / Silent
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low / Silent
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate (Cooling)
High
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
ECA Eligible
FVXG25K
FVXG35K
FVXG50K
2.44
1.93
2.50
3.40
A++
2.50
6.53
134
A++
2.80
4.65
842
4.63 / 4.42
A/A
270
0.148 / 0.148 / 0.088 / 0.075
600
950
215
22
38 / 32 / 26 / 23
52
3.42
2.37
3.50
4.50
A++
3.50
6.48
189
A+
3.10
4.00
1087
3.72 / 3.75
A/A
470
0.155 / 0.155 / 0.088 / 0.075
600
950
215
22
39 / 33 / 27 / 24
52
4.81
3.17
5.00
5.80
A+
5.00
5.41
324
A+
4.60
4.18
1543
3.31 / 3.69
A/A
755
0.177 / 0.177 / 0.122 / 0.100
600
950
215
22
44 / 40 / 36 / 32
58
RXG25L
RXG35L
RXG50L
550 x 765 x 300
35
735 x 825 x 315
48
35
1ph
4.64
5.5
10
2.68
4.4
10
6.04
7.4
20
3+E / 1.5
1/4 (6.4) / 1/2 (12.7)
30
20
10
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
15
10
1.05
46 / 43
61
0.575
20
15
10
20
1.05
48 / 44
63
0.616
1.60
48 / 44
63
0.830
●
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
£631.00
£504.00
£1,135.00
£679.00
£585.00
£1,264.00
Accessories:
£744.00
£789.00
£1,533.00
Notes:
Accessory Ref
Description
Trade Price
BRC073
BRP069A42
BRCW901A03
BRCW901A08
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
BKS028
K.CWB90-2
K.DT1
K.CGS
K.CGM
Optional Wired Remote controller: BRC1E52 style
Wifi adaptor for on-line controller
3m connection cable for BRC073
8m connection cable for BRC073
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Leg for floor-standing installation
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£80.00
£50.00
£17.00
£22.00
£75.00
£132.00
£164.00
£151.00
£393.00
£37.00
£54.00
£214.00
£296.00
i)All fan coils supplied as standard with
infrared remote controller ARC466AZ
ii)All fan coil units standard with auto restart
after power failure
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Control option is either hard-wired
remote, or Wi-Fi adaptor
v)Minimum ambient operating
temperatures:
RXG
Cooling
Heating
-10°C
-15°C
Features:
> Radiant Heat panel provides radiator-like warming at the touch of a button
> Energy efficient units: full range A class energy labels
> Wireless remote controller provides a 7-day schedule timer, enabling the user to program the air conditioning daily or weekly, with up to 4 actions per day
> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
I
W I- F O L
TR
> Extremely quiet in operation: down to 19dBA sound pressure level
CO N A P P
V IA
>Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before
the system stops, so you can sleep more comfortably
>Vertical auto swing system automatically makes the louvers move up and down, creating an even distribution of air
through the room to ensure a harmonized temperature
>Flexible installation: Can be installed against a wall, recessed or standing on the floor (installation leg required, see accessories list).
Ideal for installation beneath a window
> Suitable for multi model applications
> Re-use of existing R22 and R407 piping possible
18
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
FVXS-F / RXS-L
Floor Standing Cased
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low / Silent
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low / Silent
Sound Power
High
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
High
Air Flow Rate (Cooling)
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
FVXS25F
FVXS35F
FVXS50F
2.44
1.87
2.50
3.40
A+
2.50
5.74
152
A+
2.60
4.56
798
4.12 / 4.42
A/A
303
0.137 / 0.137 / 0.080 / 0.068
600
700
210
14
38 / 32 / 26 / 23
52
3.42
2.34
3.50
4.50
A+
3.50
5.60
219
A
2.90
3.93
1033
3.30 / 3.78
A/A
530
0.142 / 0.142 / 0.082 / 0.075
600
700
210
14
39 / 33 / 27 / 24
52
4.89
3.21
5.00
5.80
A+
5.00
5.89
297
A
4.20
3.80
1546
3.23 / 3.63
A/A
775
0.178 / 0.178 / 0.130 / 0.110
600
700
210
14
44 / 40 / 36 / 32
60
RXS25L3
RXS35L3
RXS50L
550 x 765 x 285
34
550 x 765 x 285
34
1ph
4.70
4.3
10
735 x 825 x 300
47
3.30
3.3
10
6.80
6.8
20
3+E / 1.5
1/4 (6.4) / 1/2 (12.7)
30
20
10
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
15
10
1.0
46 / 43
59
0.558
20
15
10
20
1.2
48 / 44
61
0.600
£523.00
£476.00
£999.00
£564.00
£552.00
£1,116.00
Accessories:
1.7
48 / 44
62
0.848
£616.00
£694.00
£1,310.00
Notes:
Accessory Ref
Description
Trade Price
BRP069A42
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
K.CWB90-2
K.DT1
K.CGS
K.CGM
Wifi adaptor for on-line controller
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£50.00
£75.00
£132.00
£164.00
£151.00
£37.00
£54.00
£214.00
£296.00
i)All fan coils supplied as standard with
infrared remote controller
ii)All fan coil units standard with auto restart
after power failure
iii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iv)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
> Extremely quiet, energy efficient and can be installed against the wall or recessed
> Wireless remote controller with weekly timer: provides a 7-day schedule timer, enabling daily or weekly programming. Up to 4 actions per day possible
> Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops
> Powerful operation: activates the maximum air volume for 20 minutes before returning to its original setting
> Titanium apatite photocatalytic air purifying filter: superior purification and deodorisation of the air inside the room
> Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature
I
W I- F O L
TR
> Suitable for multi model applications
CO N A P P
V IA
> Re-use of existing R22 and R407C piping possible
Price List 2016
19
SPLIT, SKY AIR HEAT PUMPS
FLXS-B / RXS-L
Flexi-Floor or Ceiling Mounted
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low / Silent
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low / Silent
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate (Cooling)
High
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
FLXS25B
FLXS35B9
FLXS50B
2.44
1.65
2.50
3.40
A
2.50
5.19
169
A
2.50
3.80
921
3.85 / 3.54
A/B
325
0.127 / 0.127 / 0.100 / 0.087
490
1050
200
16
37 / 34 / 31 / 28
51
3.34
2.14
3.50
4.00
B
3.50
4.87
252
A
2.90
3.80
1068
2.88 / 3.57
B/B
608
0.143 / 0.127 / 0.110 / 0.093
490
1050
200
16
38 / 35 / 32 / 29
53
4.82
3.16
4.90
6.10
A
4.90
5.25
326
A
4.20
3.80
1546
2.85 / 3.35
C/C
860
0.190 / 0.190 / 0.142 / 0.125
490
1050
200
17
47 / 43 / 39 / 36
60
RXS25L3
RXS35L3
RXS50L
550 x 765 x 285
34
550 x 765 x 285
34
1ph
5.10
4.3
10
735 x 825 x 300
47
3.60
3.3
10
7.60
6.8
20
3+E / 1.5
1/4 (6.4) / 1/2 (12.7)
30
20
10
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
15
10
1.0
46 / 43
59
0.558
20
15
10
20
1.2
48 / 44
61
0.600
£376.00
£476.00
£852.00
£423.00
£552.00
£975.00
Accessories:
1.7
48 / 44
62
0.848
£459.00
£694.00
£1,153.00
Notes:
Accessory Ref
Description
Trade Price
KRP413A1S
KRP928A2S
KLIC-DD
RTD-RA
K.CWB90-2
K.DT1
K.CGS
K.CGM
Adaptor PCB for remote on/off control - constant/pulse contact
Adaptor PCB for interface to Daikin centralised control systems
KNX interface for Split type systems
Adaptor PCB for Modbus connection and/or extended system functions
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£75.00
£132.00
£164.00
£151.00
£37.00
£54.00
£214.00
£296.00
Features:
i)All fan coils supplied as standard with
infrared remote controller
ii)Wired controller, KLIC-DI and RTD-RA
options cannot be combined
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
> Can be installed EITHER as ceiling mounted OR wall unit
>Vertical auto swing: flaps automatically swing up and down to ensure efficient air and temperature distribution in both floor level and ceiling
suspended installation
> Home Leave setting maintains pre-set temperature during periods of extended absence
> Night set mode: prevents any sudden change in room temperature by gently raising/lowering the temperature before the system stops
> Fan speed: 5 fan speeds can be selected, high to super low
> Suitable for multi model applications
> Re-use of existing R22 and R407C piping possible
20
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
FNQ-A / RXS-L
Concealed Floor Standing
Indoor Units
Vertical Ducted
Capacity
Seasonal Efficiency
(EN14825
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
External Static Pressure
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
High / Nominal
Height (with legs)
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate (Cooling)
High
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
Pa
mm
mm
mm
kg
dBA
dBA
mm
kg
FNQ25A
FNQ35A
FNQ50A
FNQ60A
2.54
1.89
2.40
3.20
A+
2.60
5.63
162
A+
2.80
4.24
925
3.77 / 4.00
A/A
345
0.145 / 0.133 / 0.122
3.32
2.26
3.40
4.00
A+
3.40
5.65
211
A+
2.90
4.05
1002
3.06 / 3.48
B/B
556
0.145 / 0.133 / 0.122
4.89
3.66
5.00
5.80
A+
5.00
5.72
306
A+
4.00
4.09
1369
3.35 / 3.34
A/C
746
0.267 / 0.247 / 0.225
5.86
4.11
6.00
7.00
A
6.00
5.51
381
A+
4.60
4.16
1548
2.68 / 3.11
D/D
1119
0.225 / 0.247 / 0.025
48 / 30
620 (720)
750
200
23
33 / 31 / 28
53
49 / 40
620 (720)
1150
200
30
36 / 33 / 30
56
RXS25L3
550 x 765 x 285
34
RXS35L3
550 x 765 x 285
34
2.90
3.3
10
4.70
4.3
10
RXS50L
735 x 825 x 300
47
RXS60L
735 x 825 x 300
48
6.30
6.8
20
9.40
10.2
20
1ph
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
3+E / 1.5
1/4 (6.4) / 1/2 (12.7)
20
15
10
20
15
10
30
20
10
30
20
10
1.0
46 / 43
59
0.558
1.2
48 / 44
61
0.600
1.7
48 / 44
61
0.848
1.5
49 / 46
62
0.836
£407.00
£476.00
£883.00
£503.00
£552.00
£1,055.00
£586.00
£694.00
£1,280.00
£646.00
£740.00
£1,386.00
20
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC4C65
BRC2E52
Wireless remote controller
Wired Simplified remote controller (without auto swing)
Recessed simplified remote (see page 100 for options)
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£152.00
£80.00
£180.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£54.00
£214.00
£296.00
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4B
K.RSS
RS-SE
K.CWB90-2
K.DT1
K.CGS
K.CGM
i)Fan-coils supplied with BRC1E52A hard
wired remote
ii)All fan coil units standard with auto restart
after power failure
iii)Fan-coils supplied as standard with
air filter
iv)FNQ-A supplied with 100mm high legs
for optional mounting
v)Minimum ambient operating
temperature:
RXS
Cooling
Heating
-10°C
-15°C
Features:
> Requires very little installation space
> Low height makes it ideal for installation beneath window
> Connect to multi for residential solution
> Connect to Sky Air for twin, triple or double applications
> External static pressure of up to 49Pa
Price List 2016
21
SPLIT, SKY AIR HEAT PUMPS
FVQ-C / RZQG-L
Floor Standing – Seasonal Smart
Indoor Units
Single Phase
FVQ71C
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
FVQ100C
FVQ125C
3 Phase
FVQ140C
FVQ71C
FVQ100C
FVQ140C
RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Height x Width x Depth
Weight
Electrical Details
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
Nominal
mm
kg
990 x 940
x 320
69
1430 x 940
x 320
95
A
A
A
8.26
4
20
10.18
4
32
1430 x 940
x 320
95
1430 x 940
x 320
95
990 x 940
x 320
80
1430 x 940
x 320
101
15.29
4
32
17.04
4
32
3.11
4
16
3.83
4
20
1ph
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
ECA Eligible
50
30
30
2.9
48 / 43
64
0.983
£999.00
£1,191.00
£2,190.00
1430 x 940
x 320
101
1430 x 940
x 320
101
5.75
4
20
6.41
4
20
3ph
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50 / 45
51 / 45
66
67
1.166
1.166
75
30
30
50
30
30
4.0
52 / 45
69
1.400
2.9
48 / 43
64
0.983
●
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50 / 45
51 / 45
66
67
1.166
1.166
75
30
30
4.0
52 / 45
69
1.400
●
£1,098.00
£1,514.00
£2,612.00
£1,211.00
£1,666.00
£2,877.00
£1,302.00
£1,901.00
£3,203.00
£999.00
£1,227.00
£2,226.00
Accessories:
£1,098.00
£1,584.00
£2,682.00
£1,211.00
£1,743.00
£2,954.00
£1,302.00
£2,002.00
£3,304.00
Notes:
Accessory Ref
Description
Trade Price
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£92.00
£190.00
£235.00
£251.00
£185.00
£37.00
£46.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)All fan coil units standard with auto restart
after power failure
iii)Minimum ambient operating
temperatures:
RZQG
RZQSG
Features:
> Seasonally Efficient Inverter Technology gives up to 25% better efficiency than Inverter Technology
> Vertical air flow pattern can be adjusted manually to match requirements in different sized interiors or irregularly shaped rooms
> A wired BRC1E52A remote controller is mounted on the front of the unit (standard)
> Controllable horizontal air-blow patterns, via remote control
> Very efficient for use in rooms with high ceilings
> Fan speed: 2 fan speeds can be selected, high or low
> Re-use of existing R22 and R407C piping possible
> Comms, computer and server room cooling possible with EDP setting (Seasonal Smart)
> Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)
> DIII net compatibility as standard
22
FVQ125C
7.76
10.80
13.60
14.90
7.76
10.80
13.60
14.90
5.32
7.44
9.30
10.25
5.32
7.44
9.30
10.25
6.80
9.50
12.00
13.40
6.80
9.50
12.00
13.40
7.50
10.80
13.50
15.50
7.50
10.80
13.50
15.50
A++
A+
A+
A++
A+
A+
6.80
9.50
12.00
6.80
9.50
12.00
6.31
5.61
5.61
6.31
5.61
5.61
378
593
749
378
593
749
A+
A+
A
A+
A+
A
6.33
11.30
11.30
6.33
11.30
11.30
4.05
4.20
3.87
4.05
4.20
3.87
2189
3767
4088
2189
3767
4088
3.37 / 3.64
3.81 / 4.14
3.21 / 3.7
3.21 / 3.61
3.37 / 3.64
3.81 / 4.14
3.21 / 3.7
3.21 / 3.61
A/A
A/A
A/A
A/A
A/A
A/A
A/A
A/A
1010
1245
1870
2085
1010
1245
1870
2085
0.300 / 0.267 / 0.467 / 0.417 / 0.467 / 0.433 / 0.500 / 0.467 / 0.300 / 0.267 / 0.467 / 0.417 / 0.467 / 0.433 / 0.500 / 0.467 /
0.233
0.367
0.400
0.433
0.233
0.367
0.400
0.433
1850
1850
1850
1850
1850
1850
1850
1850
600
600
600
600
600
600
600
600
270
350
350
350
270
350
350
350
39
47
47
47
39
47
47
47
43 / 41 / 38
50 / 47 / 44
51 / 48 / 46
53 / 51 / 48
43 / 41 / 38
50 / 47 / 44
51 / 48 / 46
53 / 51 / 48
55
62
63
65
55
62
63
65
Residential, Commercial and Industrial
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
FVQ-C / RZQSG-L
Floor Standing – Seasonal Classic
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
3 Phase
FVQ71C
FVQ100C
FVQ125C
FVQ140C
FVQ100C
FVQ125C
FVQ140C
7.28
4.99
6.80
7.50
A
6.80
5.50
433
A
6.33
3.86
2296
3.21 / 3.61
A/A
1059
0.300 / 0.267 /
0.233
1850
600
270
39
43 / 41 / 38
55
10.80
7.44
9.50
10.80
A
9.50
5.50
605
A+
7.60
4.01
2654
3.21 / 3.61
A/A
1480
0.467 / 0.417 /
0.367
1850
600
350
47
50 / 47 / 44
62
13.60
9.30
12.00
13.50
A
12.00
5.50
764
A
7.60
3.85
2764
2.81 / 3.41
C/B
2135
0.467 / 0.433 /
0.400
1850
600
350
47
51 / 48 / 46
60
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
0.500 / 0.467 /
0.433
1850
600
350
47
53 / 51 / 48
63
10.80
7.44
9.50
10.80
A
9.50
5.50
605
A+
7.60
4.01
2654
3.21 / 3.61
A/A
1480
0.467 / 0.417 /
0.367
1850
600
350
47
50 / 47 / 44
59
13.60
9.30
12.00
13.50
A
12.00
5.50
764
A
7.60
3.85
2764
2.81 / 3.41
C/B
2135
0.467 / 0.433 /
0.400
1850
600
350
47
51 / 48 / 46
60
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
0.500 / 0.467 /
0.433
1850
600
350
47
53 / 51 / 48
63
RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
770 x 900 x 320
72
8.66
4
20
50
15
30
2.75
49 / 49
65
0.833
£999.00
£820.00
£1,819.00
990 x 940 x 320
74
1ph
12.10
17.45
4
4
32
32
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53 / 49
54 / 49
70
70
1.266
1.283
£1,098.00
£1,135.00
£2,233.00
£1,211.00
£1,245.00
£2,456.00
1430 x 940 x 320
104
18.19
4
32
50
30
30
4.0
53 / 49
69
1.383
£1,302.00
£1,386.00
£2,688.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
4.55
6.56
6.84
4
4
4
20
20
20
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53 / 49
54 / 49
53 / 49
70
70
69
1.266
1.283
1.383
£1,098.00
£1,170.00
£2,268.00
£1,211.00
£1,282.00
£2,493.00
£1,302.00
£1,428.00
£2,730.00
Price List 2016
23
SPLIT, SKY AIR HEAT PUMPS
FHQ-CB / RZQG-L
Ceiling Suspended – Seasonal Smart
Indoor Units
Single Phase
FHQ71CB
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
Nominal
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
FHQ100CB
3 Phase
FHQ125CB
FHQ140CB
FHQ71CB
FHQ100CB
FHQ125CB
RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
990 x 940 x 320
1430 x 940 x 320
990 x 940 x 320
1430 x 940 x 320
69
95
80
101
1ph
3ph
A
7.27
10.18
14.63
16.55
2.74
3.83
5.50
6.23
A
4
4
4
4
4
4
4
4
A
20
32
32
32
16
20
20
20
3+E / 1.5
3+E / 1.5
inches (mm)
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 5/8 (15.9)
m
50
75
75
75
50
75
75
75
m
30
30
30
30
30
30
30
30
m
30
30
30
30
30
30
30
30
g/m
Refer to Installation Manual
Refer to Installation Manual
kg
2.9
4.0
4.0
4.0
2.9
4.0
4.0
4.0
dBA
48 / 43
50 / 45
51 / 45
52 / 45
48 / 43
50 / 45
51 / 45
52 / 45
dBA
64
66
67
69
64
66
67
69
m3/sec
0.983
1.166
1.166
1.400
0.983
1.166
1.166
1.400
mm
kg
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
●
●
●
£926.00
£1,191.00
£2,117.00
£983.00
£1,514.00
£2,497.00
£1,229.00
£1,666.00
£2,895.00
£1,459.00
£1,901.00
£3,360.00
●
●
●
£926.00
£1,227.00
£2,153.00
£983.00
£1,584.00
£2,567.00
£1,229.00
£1,743.00
£2,972.00
Accessories:
£1,459.00
£2,002.00
£3,461.00
Notes:
Accessory Ref
Description
Trade Price
BRC7G53
EKRORO4
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
K.CWB90-2
K.CWB140-2
K.DT2
K.CGS
K.CGM
K.CGL
KDDQ50A140
Wireless remote controller
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
Fresh air intake kit for up to 20% fresh air
£152.00
£29.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£46.00
£59.00
£214.00
£296.00
£354.00
£158.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7GA53 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RZQG
RZQSG
Features:
> Suitable for ceiling heights of up to 3.8m without loss of capacity
>Seasonally Efficient Inverter Technology gives up to 25% better efficiency
than inverter technology
>Forced off: The optional forced off enables the unit to switch off
automatically, for example when a window is opened
> Re-use of existing R22 and R407C piping possible
24
FHQ140CB
7.76
10.80
13.60
14.90
7.76
10.80
13.60
14.90
5.32
7.44
9.30
10.25
5.32
7.44
9.30
10.25
6.80
9.50
12.00
13.40
6.80
9.50
12.00
13.40
7.50
10.80
13.50
15.50
7.50
10.80
13.50
15.50
A++
A++
A+
A++
A++
A+
6.80
9.50
12.00
6.80
9.50
12.00
6.95
6.11
6.01
6.95
6.11
6.01
343
454
699
343
545
699
A+
A++
A+
A+
A++
A+
7.60
11.30
14.13
7.60
11.30
14.13
4.32
4.61
4.23
4.32
4.61
4.23
2462
3431
4677
2462
3431
4677
3.82 / 4.13
3.81 / 4.15
3.52 / 3.89
3.31 / 3.63
3.82 / 4.13
3.81 / 4.15
3.52 / 3.89
3.31 / 3.63
A/A
A/A
A/A
A/A
A/A
A/A
A/A
A/A
890
1245
1790
2025
890
1245
1790
2025
0.342 / 0.283 / 0.467 / 0.400 / 0.517 / 0.450 / 0.567 / 0.483 / 0.342 / 0.283 / 0.467 / 0.400 / 0.517 / 0.450 / 0.567 / 0.483 /
0.233
0.333
0.383
0.400
0.233
0.333
0.383
0.400
235
235
235
235
235
235
235
235
1270
1590
1590
1590
1270
1590
1590
1590
690
690
690
690
690
690
690
690
32
38
38
38
32
38
38
38
38 / 36 / 34
42 / 38 / 34
44 / 41 / 37
46 / 42 / 38
38 / 36 / 34
42 / 38 / 34
44 / 41 / 37
46 / 42 / 38
53
56
59
60
53
56
59
60
Residential, Commercial and Industrial
> Suitable for Twin, Triple and Double Twin applications
>Comms, computer and server room cooling
possible with EDP setting (Seasonal Smart)
>Selectable evaporating & condensing temperature
for greater operating efficiency (Seasonal Smart)
> DIII net compatibility as standard
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
FHQ-CB / RZQSG-L
Ceiling Suspended – Seasonal Classic
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
3 Phase
FHQ71CB
FHQ100CB
FHQ125CB
FHQ140CB
FHQ100CB
FHQ125CB
FHQ140CB
7.28
4.99
6.80
7.50
A+
6.80
5.61
424
A
7.60
3.90
2727
3.46 / 4
A/A
985
0.342 / 0.283 /
0.233
235
1270
690
32
38 / 36 / 34
53
10.80
7.44
9.50
10.80
A+
9.50
5.61
593
A
7.60
3.91
2722
3.21 / 3.61
A/A
1480
0.467 / 0.400 /
0.333
235
1590
690
38
42 / 38 / 34
56
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A+
7.60
4.01
2654
2.89 / 3.62
C/A
2075
0.517 / 0.450 /
0.383
235
1590
690
38
44 / 41 / 37
59
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
0.567 / 0.483 /
0.400
235
1590
690
38
46 / 42 / 38
60
10.80
7.44
9.50
10.80
A+
9.50
5.61
593
A
7.60
3.91
2722
3.21 / 3.61
A/A
1480
0.467 / 0.400 /
0.333
235
1590
690
38
42 / 38 / 34
56
13.60
9.30
12.00
13.50
A+
12.00
5.61
748
A+
7.60
4.01
2654
2.89 / 3.62
C/A
2075
0.517 / 0.450 /
0.383
235
1590
690
38
44 / 41 / 37
59
14.90
10.25
13.40
15.50
3.01 / 3.41
B/B
2225
0.567 / 0.483 /
0.400
235
1590
690
38
46 / 42 / 38
60
RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
770 x 900 x 320
72
8.05
4
20
50
15
30
2.75
49 / 49
65
0.866
£926.00
£820.00
£1,746.00
990 x 940 x 320
74
1ph
12.10
16.96
4
4
32
32
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53 / 49
54 / 49
70
70
1.266
1.283
£983.00
£1,135.00
£2,118.00
£1,229.00
£1,245.00
£2,474.00
1430 x 940 x 320
95
18.19
4
32
50
30
30
4.0
53 / 49
69
1.383
£1,459.00
£1,386.00
£2,845.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
4.52
6.34
6.80
4
4
4
20
20
20
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53 / 49
54 / 49
53 / 49
70
70
69
1.266
1.283
1.383
£983.00
£1,170.00
£2,153.00
£1,229.00
£1,282.00
£2,511.00
£1,459.00
£1,428.00
£2,887.00
Price List 2016
25
SPLIT, SKY AIR HEAT PUMPS
AHQ-C / AZQS
Ceiling Suspended
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
3 Phase
AHQ71C
AHQ100C
AHQ125C
AHQ140C
AHQ100C
AHQ125C
AHQ140C
7.28
4.99
6.80
7.50
B
6.80
4.65
511
A
6.33
3.80
2332
3.03 / 3.05
B/D
1110
23.8 / 18.9
260
1320
634
38
49 / 46
52
10.80
7.44
9.50
10.80
B
9.50
4.60
723
A
7.60
3.80
2800
2.62 / 3.41
D/B
1810
31.1 / 24.8
260
1538
634
45
51 / 45
73
13.60
9.30
12.10
13.50
2.63 / 3.61
D/A
2300
34.4 / 27.2
260
1786
634
54
52 / 47
73
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159
43.9 / 28.3
285
1902
680
70
53 / 47
75
10.80
7.44
9.50
10.80
B
9.50
4.60
723
A
7.60
3.80
2800
2.62 / 3.41
D/B
1810
31.1 / 24.8
260
1538
634
45
51 / 45
73.00
13.60
9.30
12.10
13.50
2.63 / 3.61
D/A
2300
34.4 / 27.2
260
1786
634
54
52 / 47
73.00
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159
43.9 / 28.3
285
1902
680
70
53 / 47
75.00
AZQS71BV1
AZQS100B8V1
AZQS125B8V1
AZQS140B8V1
AZQS100BY1
AZQS125BY1
770x900x320
67
990x940x320
data-book
48
64
73
74
1~ / 50 / 220 - 240
14.79
18.80
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
30
30
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£625.00
£714.00
£1,339.00
£756.00
£878.00
£1,634.00
9.07
4
20
3/8 / 5/8
30
30
30
£950.00
£986.00
£1,936.00
1430x940x320
95
data-book
53
70
990x940x320
81
3~ / 50 / 400
4.92
6.25
4
4
16
16
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
30
30
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£1,098.00
£1,104.00
£2,202.00
£756.00
£926.00
£1,682.00
17.66
4
32
3/8 / 5/8
30
30
30
Accessories:
5.87
4
20
3/8 / 5/8
30
30
30
data-book
53
70
£1,098.00
£1,164.00
£2,262.00
Notes:
Accessory Ref
Description
Trade Price
R04084124324
K.CWB90-2
K.CWB140-2
K.DT1
K.DT2
K.CGM
K.CGL
PCB Adaptor for group control (1 per fan-coil)
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with K.CWB90-2
Condensate drip tray for use with K.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£82.00
£36.00
£46.00
£54.00
£59.00
£296.00
£354.00
Features:
i)Fan-coils supplied with both ARCWB hard
wired remote & infra-red remote
ii)Replacement Technology not applicable
to AZQS
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperature:
AZQS
> Hard wired remote ARCWB as standard
> Long airflow
> 3 step fan speed and auto mode
> Turbo mode to quickly heat / cool room
> Ideal for rooms with solid or high ceilings
WHOLESALE
EXCLUSIVE
26
£950.00
£1,038.00
£1,988.00
AZQS140BY1
1430x940x320
101
Residential, Commercial and Industrial
Cooling
Heating
-5°C
-15°C
Refrigerant
Indoor
Model
Ururu Sarara
Emura (Silver)
R32
Wall Mount
Emura (White)
FTXM (Standard Inverter)
Emura (Silver)
Emura (White)
FTXS (Standard Inverter)
Wall Mount
FTX (Low Inverter)
Smart Single Phase
Smart Three Phase
Classic Single Phase
Classic Three Phase
Nexura (Stylish Floor
Standing Cased)
FVXS (Floor Standing
Cased)
Smart Single Phase
R410A
Smart Three Phase
Floor Standing
Classic Single Phase
Classic Three Phase
Flexi (FLXS)
Concealed Floor Standing
(FNQ)
Smart Single Phase
Smart Three Phase
Ceiling Suspended
Classic Single Phase
Classic Three Phase
RXS
Capacity
2.5kW
3.5kW
5.0kW
2.0kW
2.5kW
3.5kW
5.0kW
2.0kW
2.5kW
3.5kW
5.0kW
2.0kW
2.5kW
3.5kW
4.2kW
5.0kW
6.0kW
7.1kW
2.0kW
2.5kW
3.5kW
5.0kW
2.0kW
2.5kW
3.5kW
5.0kW
2.0kW
2.5kW
3.5kW
4.2kW
5.0kW
6.0kW
7.1kW
2.0kW
2.5kW
3.5kW
5.0kW
6.0kW
7.1kW
7.1kW
10.0kW
7.1kW
10.0kW
7.1kW
10.0kW
10.0kW
2.5kW
3.5kW
5.0kW
2.5kW
3.5kW
5.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
10.0kW
12.5kW
14.0kW
2.5kW
3.5kW
5.0kW
2.5kW
3.5kW
5.0kW
6.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
10.0kW
12.5kW
14.0kW
3.5kW
5.0kW
6.0kW
Order Code
SB.FTXZ25N/RXZN
SB.FTXZ35N/RXZN
SB.FTXZ50N/RXZN
SB.FTXJ20MS/RXJM
SB.FTXJ25MS/RXJM
SB.FTXJ35MS/RXJM
SB.FTXJ50MS/RXJM
SB.FTXJ20MW/RXJM
SB.FTXJ25MW/RXJM
SB.FTXJ35MW/RXJM
SB.FTXJ50MW/RXJM
SB.FTXM20M/RXMM
SB.FTXM25M/RXMM
SB.FTXM35M/RXMM
SB.FTXM42M/RXMM
SB.FTXM50M/RXMM
SB.FTXM60M/RXMM
SB.FTXM71M/RXMM
SB.FTXG20LS_WIFI/R
SB.FTXG25LS_WIFI/R
SB.FTXG35LS_WIFI/R
SB.FTXG50LS_WIFI/R
SB.FTXG25LW_WIFI/R
SB.FTXG35LW_WIFI/R
SB.FTXG50LW_WIFI/R
SB.FTXG20LW_WIFI/R
SB.FTXS20K/RXSL3
SB.FTXS25K/RXSL3
SB.FTXS35K/RXSL3
SB.FTXS42K/RXSL
SB.FTXS50K/RXSL
SB.FTXS560G/RXSL
SB.FTXS71G/RXSF8
SB.FTX20KV/RXK
SB.FTX25KV/RXK
SB.FTX35KV/RXK
SB.FTX50KV/RXK
SB.FTX60KV/RXK
SB.FTX71KV/RXK
SB.FAQ71C9_F/GLV
SB.FAQ100C9_F/GLV
SB.FAQ71C9_F/GLY
SB.FAQ100C9_F/GLY
SB.FAQ71C9_F/SLV
SB.FAQ100C9_F/SLV
SB.FAQ100C9_F/SLY
SB.FVXG25K/RXGL
SB.FVXG35K/RXGL
SB.FVXG50K/RXGL
SB.FVXS25F/RXSL3
SB.FVXS35F/RXSL3
SB.FVXS50F/RXSL
SB.FVQ71C_F/GLV
SB.FVQ100C_F/GLV
SB.FVQ125C_F/GLV
SB.FVQ140C_F/GLV
SB.FVQ71C_F/GLY
SB.FVQ100C_F/GLY
SB.FVQ125C_F/GLY
SB.FVQ140C_F/GLY
SB.FVQ71C_F/SLV
SB.FVQ100C_F/SLV
SB.FVQ125C_F/SLV
SB.FVQ140C_F/SLV
SB.FVQ100C_F/SLY
SB.FVQ125C_F/SLY
SB.FVQ140C_F/SLY
SB.FLXS25B/RXSL3
SB.FLXS35B9/RXSL3
SB.FLXS50B/RXSL
SB.FNQ25A_F/RXSL3
SB.FNQ35A_F/RXSL3
SB.FNQ5OA_F/RXSL
SB.FNQ60A_F/RXSL
SB.FHQ71CB_F/GLV
SB.FHQ100CB_F/GLV
SB.FHQ125CB_F/GLV
SB.FHQ140CB_F/GLV
SB.FHQ71CB_F/GLY
SB.FHQ100CB_F/GLY
SB.FHQ125CB_F/GLY
SB.FHQ140CB_F/GLY
SB.FHQ71CB_F/SLV
SB.FHQ100CB_F/SLV
SB.FHQ125CB_F/SLV
SB.FHQ140CB_F/SLV
SB.FHQ100CB_F/SLY
SB.FHQ125CB_F/SLY
SB.FHQ140CB_F/SLY
SB.FHQ35CB_F/RXSL3
SB.FHQ5OCB_F/RXSL
SB.FHQ60CB_F/RXSL
Product Codes Included
FTXZ25N x 1 & RXZ25N x 1
FTXZ35N x 1 & RXZ35N x 1
FTXZ50N x 1 & RXZ50N x 1
RXJ20M & FTXJ20MS
RXJ25M & FTXJ25MS
RXJ35M & FTXJ35MS
RXJ50M & FTXJ50MS
RXJ20M & FTXJ20MW
RXJ25M & FTXJ25MW
RXJ35M & FTXJ35MW
RXJ50M & FTXJ50MW
RXM20M & FTXM20M
RXM25M & FTXM25M
RXM35M & FTXM35M
RXM42M & FTXM42M
RXM50M & FTXM50M
RXM60M & FTXM60M
RXM71M & FTXM71M
BRP069A41 x 1 & FTXG20LS x 1 & RXG20L x 1
BRP069A41 x 1 & FTXG25LS x 1 & RXG25L x 1
BRP069A41 x 1 & FTXG35LS x 1 & RXG35L x 1
BRP069A41 x 1 & FTXG50LS x 1 & RXG50L x 1
BRP069A41 x 1 & FTXG25LW x 1 & RXG25L x 1
BRP069A41 x 1 & FTXG35LW x 1 & RXG35L x 1
BRP069A41 x 1 & FTXG50LW x 1 & RXG50L x 1
BRP069A41 x 1 & FTXG20LW x 1 & RXG20L x 1
FTXS20K x 1 & RXS20L3 x 1
FTXS25K x 1 & RXS25L3 x 1
FTXS35K x 1 & RXS35L3 x 1
FTXS42K x 1 & RXS42L x 1
FTXS50K x 1 & RXS50L x 1
FTXS60G x 1 & RXS60L x 1
FTXS71G x 1 & RXS71F8 x 1
RX20K & FTX20KV
RX25K & FTX25KV
RX35K & FTX35KV
RX50K & FTX50KV
RX60K & FTX60KV
RX71K & FTX71KV
BRC1E52A x 1 & FAQ71C x 1 & RZQG71L9V1 x 1
BRC1E52A x 1 & FAQ100C x 1 & RZQG100L9V1 x 1
BRC1E52A x 1 & FAQ71C x 1 & RZQG71L8Y1 x 1
BRC1E52A x 1 & FAQ100C x 1 & RZQG100L8Y1 x 1
BRC1E52 x 1 & FAQ71C x 1 & RZQSG71L3V1 x 1
BRC1E52A x 1 & FAQ100C x 1 & RZQSG100L9V1 x 1
BRC1E52A x 1 & FAQ100C x 1 & RZQSG100L8Y1 x 1
FVXG25K x 1 & RXG25L x 1
FVXG35K x 1 & RXG35L x 1
FVXG50K x 1 & RXG50L x 1
FVXS25F x 1 & RXS25L3 x 1
FVXS35F x 1 & RXS35L3 x 1
FVXS50F x 1 & RXS50L x 1
BRC1E52A x 1 & FVQ71C x 1 & RZQG71L9V1 x 1
BRC1E52A x 1 & FVQ100C x 1 & RZQG100L9V1 x 1
BRC1E52A x 1 & FVQ125C x 1 & RZQG125L9V1 x 1
BRC1E52A x 1 & FVQ140C x 1 & RZQG140L9V1 x 1
BRC1E52A x 1 & FVQ71C x 1 & RZQG71L8Y1 x 1
BRC1E52A x 1 & FVQ100C x 1 & RZQG100L8Y1 x 1
BRC1E52A x 1 & FVQ125C x 1 & RZQG125L8Y1 x 1
BRC1E52A x 1 & FVQ140C x 1 & RZQG140LY1 x 1
BRC1E52A x 1 & FVQ71C x 1 & RZQSG71L3V1 x 1
BRC1E52A x 1 & FVQ100C x 1 & RZQSG100L9V1 x 1
BRC1E52A x 1 & FVQ125C x 1 & RZQSG125L9V1 x 1
BRC1E52A x 1 & FVQ140C x 1 & RZQSG140L9V1 x 1
BRC1E52A x 1 & FVQ100C x 1 & RZQSG100L8Y1 x 1
BRC1E52A x 1 & FVQ125C x 1 & RZQSG125L8Y1 x 1
BRC1E52A x 1 & FVQ140C x 1 & RZQSG140LY1 x 1
FLXS25B x 1 & RXS25L3 x 1
FLXS35B9 x 1 & RXS35L3 x 1
FLXS50B x 1 & RXS50L x 1
BRC1E52A x 1 & FNQ25A x 1 & RXS35L3 x 1
BRC1E52A x 1 & FNQ35A x 1 & RXS35L3 x 1
BRC1E52A x 1 & FNQ50A x 1 & RXS50L x 1
BRC1E52A x 1 & FNQ60A x 1 & RXS60L x 1
BRC1E52A x 1 & FHQ71CB x 1 & RZQG71L9V1 x 1
BRC1E52A x 1 & FHQ100CB x 1 & RZQG100L9V1 x 1
BRC1E52A x 1 & FHQ125CB x 1 & RZQG125L9V1 x 1
BRC1E52A x 1 & FHQ140CB x 1 & RZQG140L9V1 x 1
BRC1E52A x 1 & FHQ71CB x 1 & RZQG71L8Y1 x 1
BRC1E52A x 1 & FHQ100CB x 1 & RZQG100L8Y1 x 1
BRC1E52A x 1 & FHQ125CB x 1 & RZQG125L8Y1 x 1
BRC1E52A x 1 & FHQ140CB x 1 & RZQG140LY1 x 1
BRC1E52A x 1 & FHQ71CB x 1 & RZQSG71L3V1 x 1
BRC1E52A x 1 & FHQ100CB x 1 & RZQSG100L9V1 x 1
BRC1E52A x 1 & FHQ125CB x 1 & RZQSG125L9V1 x 1
BRC1E52A x 1 & FHQ125CB x 1 & RZQSG125L9V1 x 1
BRC1E52A x 1 & FHQ100CB x 1 & RZQSG100L8Y1 x 1
BRC1E52A x 1 & FHQ125CB x 1 & RZQSG125L8Y1 x 1
BRC1E52A x 1 & FHQ140CB x 1 & RZQSG140LY1 x 1
BRC1E52A x 1 & FHQ35CB x 1 & RXS35L3 x 1
BRC1E52A x 1 & FHQ50CB x 1 & RXS50L x 1
BRC1E52A x 1 & FHQ60CB x 1 & RXS60L x 1
List Price
£1,283.00
£1,490.00
£1,673.00
£831.00
£876.00
£1,003.00
£1,342.00
£778.00
£820.00
£941.00
£1,259.00
£620.00
£673.00
£779.00
£878.00
£1,039.00
£1,092.00
£1,484.00
£831.00
£873.00
£994.00
£1,317.00
£780.00
£820.00
£935.00
£1,238.00
£590.00
£641.00
£741.00
£835.00
£988.00
£1,040.00
£1,413.00
£428.00
£461.00
£533.00
£738.00
£776.00
£1,093.00
£1,940.00
£2,322.00
£1,976.00
£2,392.00
£1,569.00
£1,943.00
£1,978.00
£1,135.00
£1,264.00
£1,533.00
£999.00
£1,116.00
£1,310.00
£2,190.00
£2,612.00
£2,877.00
£3,230.00
£2,226.00
£2,682.00
£2,954.00
£3,304.00
£1,189.00
£2,233.00
£2,456.00
£2,688.00
£2,268.00
£2,493.00
£2,730.00
£852.00
£975.00
£1,153.00
£883.00
£1,055.00
£1,280.00
£1,386.00
£2,117.00
£2,497.00
£2,895.00
£3,360.00
£2,153.00
£2,567.00
£2,972.00
£3,461.00
£1,746.00
£2,118.00
£2,474.00
£2,845.00
£2,153.00
£2,511.00
£2,887.00
£1,281.00
£1,416.00
£1,532.00
Price List 2016
27
SPLIT, SKY AIR HEAT PUMPS
To simplify the order process, you may want to use the Order Code from table below.
Each code includes all products for a system (eg remote controllers, indoor units) & means you no longer need to order individual materials.
SPLIT, SKY AIR HEAT PUMPS
FCQHG-F / RZQG-L
High COP Roundflow Cassette – Seasonal Smart
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Dimensions
(with Decoration Panel)
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
Single Phase
3 Phase
FCQHG71F
FCQHG100F FCQHG125F FCQHG140F
FCQHG71F
FCQHG100F FCQHG125F FCQHG140F
7.76
10.80
13.60
14.90
7.76
10.80
13.60
14.90
5.32
7.44
9.30
10.25
5.32
7.44
9.30
10.25
6.80
9.50
12.00
13.40
6.80
9.50
12.00
13.40
7.50
10.80
13.50
15.50
7.50
10.80
13.50
15.50
A++
A++
A++
A++
A++
A++
6.80
9.50
12.00
6.80
9.50
12.00
7.00
7.00
6.61
7.00
7.00
6.61
340
475
636
340
475
636
A+
A++
A++
A+
A++
A++
7.60
11.30
12.66
7.60
11.30
12.66
4.54
4.80
4.63
4.54
4.80
4.63
2344
3296
3829
2344
3296
3829
4.09 / 4.8
4.42 / 4.99
4 / 4.4
3.35 / 4.12
4.09 / 4.8
4.42 / 4.99
4 / 4.4
3.35 / 4.14
A/A
A/A
A/A
A/A
A/A
A/A
A/A
A/A
830
1075
1500
2000
830
1075
1500
2000
0.353 / 0.270 / 0.538 / 0.428 / 0.558 / 0.445 / 0.558 / 0.455 / 0.353 / 0.270 / 0.538 / 0.428 / 0.558 / 0.445 / 0.558 / 0.455 /
0.203
0.317
0.332
0.352
0.203
0.317
0.332
0.352
288(348)
288 (348)
288 (348)
288 (348)
288(348)
288 (348)
288 (348)
288 (348)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
25 (30.4)
26 (31.4)
26 (31.4)
26 (31.4)
25 (30.4)
26 (31.4)
26 (31.4)
26 (31.4)
36 / 33 / 29
44 / 39 / 33
45 / 40 / 35
45 / 41 / 37
36 / 33 / 29
44 / 39 / 33
45 / 40 / 35
45 / 41 / 37
53
61
61
61
53
61
61
61
Height
Width
Depth
Weight (with Decoration Panel)
Sound Pressure (Cooling) High / Nom / Low
Sound Power
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
990 x 940 x 320
1430 x 940 x 320
990 x 940 x 320
1430 x 940 x 320
69
95
80
101
1ph
3ph
A
6.78
8.79
12.26
16.35
2.55
3.31
4.61
6.15
A
4
4
4
4
4
4
4
4
A
20
32
32
32
16
20
20
20
3+E / 1.5
3+E / 1.5
inches (mm)
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 5/8 (15.9)
m
50
75
75
75
50
75
75
75
m
30
30
30
30
30
30
30
30
m
30
30
30
30
30
30
30
30
g/m
Refer to Installation Manual
Refer to Installation Manual
kg
2.9
4.0
4.0
4.0
2.9
4.0
4.0
4.0
dBA
48 / 43
50 / 45
51 / 45
52 / 45
48 / 43
50 / 45
51 / 45
52 / 45
dBA
64
66
67
69
64
66
67
69
m3/sec
0.983
1.166
1.166
1.400
0.983
1.166
1.166
1.400
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
Nom
mm
kg
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
●
●
●
●
●
●
●
●
£787.00
£1,191.00
£1,978.00
£890.00
£1,514.00
£2,404.00
£972.00
£1,666.00
£2,638.00
£1,168.00
£1,901.00
£3,069.00
£787.00
£1,227.00
£2,014.00
£890.00
£1,584.00
£2,474.00
£972.00
£1,743.00
£2,715.00
£1,168.00
£2,002.00
£3,170.00
Accessories:
Accessory Ref
BRC7FA532F
BYCQ140DG
BYCQ140DW
BRYQ140A
KDBHQ55B140
KDDQ55B140 1&2
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
Notes:
Description
Wireless remote controller
Roundflow cassette decoration panel with self cleaning filter
Roundflow cassette decoration panel - white with white louvres
Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions
Sealing member for air discharge outlet
Fresh air intake kit for up to 20% fresh air - 2 part kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
Features:
Trade Price
£152.00
£310.00
£160.00
£99.00
£90.00
£233.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£46.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7FA532F Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto
restart after power failure
iv)All fan coils suppled as standard with
BYCQ140D Decoration panel
v)BYCQ140DW / BYCQ140DG Trade prices
will be reduced by £142.00 if ordered in
place of standard decoration panel
vi)Minimum ambient operating
temperatures:
RZQG
RZQSG
AZQS
Cooling
-15°C
-15°C
-5°C
Heating
-20°C
-15°C
-15°C
vii)FCQG-F / FCQHG-F compatible with
RZQG / RZQSG
viii)FCQG-F / FCQHG-F are same price
> The FCQHG model is designed for 2014 ErP regulations and has one of the highest COP values on the market
> The unique 360° radial air pattern ensures uniform air flow and temperature distribution
> Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
>Optional Self Cleaning Filter The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost
> Optional Fresh Air intake (up to 20%) possible
> Suitable for Twin, Triple and Double Twin applications (Smart & Classic)
> Re-use of existing R22 and R407C piping possible
> Selectable evaporating & condensing temperature for greater operating efficiency (Seasonal Smart)
> DIII net compatibility as standard
28
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
FCQG-F / RZQSG-L
Compact Roundflow Cassette – Seasonal Classic
Indoor Units
Single Phase
FCQG71F
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate (Cooling)
High / Nom / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure (Cooling) High / Nom / Low
Sound Power
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
High
kW
kW
kW
kW
FCQG100F
FCQG125F
3 Phase
FCQG140F
FCQG100F
FCQG125F
FCQG140F
7.28
10.80
13.60
14.90
10.80
13.60
14.90
4.99
7.44
9.30
10.25
7.44
9.30
10.25
6.80
9.50
12.00
13.40
9.50
12.00
13.40
7.50
10.80
13.50
15.50
10.80
13.50
15.50
A++
A++
A
A++
A
6.80
9.50
12.00
9.50
12.00
6.10
6.50
5.30
6.50
5.30
390
512
793
512
793
A+
A+
A+
A+
A+
6.33
7.60
8.03
7.60
8.03
4.10
4.10
4.01
4.10
4.01
2162
2596
2804
2596
2804
3.21 / 3.61
3.3 / 3.54
3.21 / 3.41
3.01 / 3.41
3.3 / 3.54
3.21 / 3.41
3.01 / 3.41
A/A
A/B
A/B
B/B
A/B
A/B
B/B
1060
1440
1870
2225
1440
1870
2225
0.250 / 0.202 / 0.152 0.380 / 0.293 / 0.207 0.433 / 0.320 / 0.207 0.267 / 0.320 / 0.207 0.380 / 0.293 / 0.207 0.433 / 0.320 / 0.207 0.267 / 0.320 / 0.207
204 (264)
246 (306)
246 (306)
246 (306)
246 (306)
246 (306)
246 (306)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
840 (950)
21 (26.4)
24 (29.4)
24 (29.4)
24 (29.4)
24 (29.4)
24 (29.4)
24 (29.4)
33 / 31 / 28
37 / 33 / 29
41 / 35 / 29
41 / 35 / 29
37 / 33 / 29
41 / 35 / 29
41 / 35 / 29
51
54
58
58
54
58
58
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
770 x 900 x 320
990 x 940 x 320
1430 x 940 x 320
990 x 940 x 320
1430 x 940 x 320
72
75
95
82
101
1ph
3ph
A
8.66
11.77
15.29
18.19
4.40
5.72
6.80
A
4
4
4
4
4
4
4
A
20
32
32
32
20
20
20
3+E / 1.5
3+E / 1.5
inches (mm)
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 5/8 (15.9)
m
50
50
50
50
50
50
50
m
15
30
30
30
30
30
30
m
30
30
30
30
30
30
30
g/m
Refer to Installation Manual
Refer to Installation Manual
kg
2.75
2.9
2.9
4.0
2.9
2.9
4.0
dBA
49 / 49
53 / 49
54 / 49
53 / 49
53 / 49
54 / 49
53 / 49
dBA
65
70
70
69
70
70
69
m3/sec
0.866
1.266
1.283
1.383
1.266
1.283
1.383
mm
kg
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
●
●
£787.00
£820.00
£1,607.00
£890.00
£1,135.00
£2,025.00
●
£972.00
£1,245.00
£2,217.00
£1,168.00
£1,386.00
£2,554.00
£890.00
£1,170.00
£2,060.00
£972.00
£1,282.00
£2,254.00
£1,168.00
£1,428.00
£2,596.00
One cassette, 3 options:
Daikin’s Roundflow Cassette range
has a solution for all your needs:
> Price
> Performance
> Highest Efficiency
>
>
>
>
>
Pair applications
30m pipe run
-5 / -15°C operating range in cooling / heating
A/A Energy Labels
R22 replacement technology
FCQG-F Series cassette
BYFQ140D Roundflow decoration panel
BRC1E52 remote control
>
>
>
>
>
Pair, twin, triple, double twin applications
50m pipe run
-15 / -15°C operating range in cooling / heating
A+/A+ Energy Labels
R22 replacement technology
>
>
>
>
>
>
Pair, twin, triple, double twin applications
75m pipe run
-15 / -20°C operating range in cooling / heating
Up to A++/A+ Energy Labels
All capacities ECA Eligible
R22 replacement technology
Price List 2016
29
SPLIT, SKY AIR HEAT PUMPS
ACQ-D / AZQS
4-Way Blow Cassette
Indoor Units
Single Phase
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate
High / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure
High / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
3 Phase
ACQ71D
ACQ100D
ACQ125D
ACQ140D
ACQ100D
ACQ125D
ACQ140D
7.28
4.99
6.80
7.50
B
6.80
4.65
512
A
6.33
3.80
2332
3.31 / 3.61
A/A
1025
24.4 / 17.6
265 (347)
820 (990)
820 (990)
31 (35)
41 / 35
54
10.80
7.44
9.50
10.80
A
9.50
5.50
605
A
7.60
3.85
2764
3.21 / 3.61
A/A
1480
29.2 / 21.0
300 (382)
820 (990)
820 (990)
39 (43)
44 / 38
56
13.60
9.30
12.10
13.50
3.10 / 3.61
B/A
1952
34.0 / 26.3
300 (382)
820 (990)
820 (990)
39 (43)
47 / 43
60
14.90
10.25
13.00
15.50
3.21 / 3.61
A/A
2025
34.0 / 26.3
300 (382)
820 (990)
820 (990)
39 (43)
47 / 43
60
10.80
7.44
9.50
10.80
A
9.50
5.50
605
A
7.60
3.85
2764
3.21 / 3.61
A/A
1480.00
29.2 / 21.0
300 (382)
820 (990)
820 (990)
39 (43)
44 / 38
56
13.60
9.30
12.10
13.50
3.10 / 3.61
B/A
1952.00
34.0 / 26.3
300 (382)
820 (990)
820 (990)
39 (43)
47 / 43
60
14.90
10.25
13.00
15.50
3.21 / 3.61
A/A
2025
34.0 / 26.3
300 (382)
820 (990)
820 (990)
39 (43)
47 / 43
60
AZQS71BV1
AZQS100BV1
AZQS120BV1
AZQS140B8V1
AZQS100BY1
AZQS125BY1
770X900X320
67
990X940X320
data-book
48
64
73
74
1~ / 50 / 220-240
12.10
15.94
4
4
32
32
3+E
3/8 / 5/8
3/8 / 5/8
30
30
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£644.00
£714.00
£1,358.00
£749.00
£878.00
£1,627.00
8.38
4
20
3/8 / 5/8
30
30
30
£836.00
£986.00
£1,822.00
1430x940x320
95
data-book
53
70
990X940X320
82
3~ / 50 / 400
4.02
5.30
4
4
16
16
3+E
3/8 / 5/8
3/8 / 5/8
30
30
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£997.00
£1,104.00
£2,101.00
£749.00
£926.00
£1,675.00
16.55
4
32
3/8 / 5/8
30
30
30
Accessories:
5.50
4
20
3/8 / 5/8
30
30
30
data-book
53
70
£997.00
£1,164.00
£2,161.00
Notes:
Accessory Ref
Description
Trade Price
R04084124324
K.CWB90-2
K.CWB140-2
K.DT1
K.DT2
K.CGM
K.CGL
PCB Adaptor for group control (1 per fan-coil)
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with K.CWB90-2
Condensate drip tray for use with K.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£82.00
£36.00
£46.00
£54.00
£59.00
£296.00
£354.00
Features:
> 4-way blow cassette
> Hard wired remote ARCWB as standard
> 7 day timer
> Knock out for connection to branch duct
> Auto swing mode for better air distribution
> Suitable for rooms with suspended ceilings
i)Fan-coils supplied with both ARCWB hard
wired remote & infra-red remote
ii)Replacement Technology not applicable
to AZQS
iii)All fan coils suppled as standard with
ADP125B decoration panel
iv)All fan coil units standard with auto restart
after power failure
v)Minimum ambient operating
temperature:
AZQS
WHOLESALE
EXCLUSIVE
30
£836.00
£1,038.00
£1,874.00
AZQS140BY1
1430x940x320
101
Residential, Commercial and Industrial
Cooling
Heating
-5°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
FCQG-F / RXS-L
Compact Roundflow Cassette
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate (Cooling)
High / Nom / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure (Cooling) High / Nom / Low
Sound Power
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate (Cooling)
High
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
FCQG35F
FCQG50F
FCQG60F
3.32
2.29
3.40
4.20
A++
3.50
6.35
193
A++
3.32
4.90
949
3.74 / 3.5
A/B
455
0.208 / 0.177 / 0.145
204 (264)
840 (950)
840 (950)
18 (23.4)
31 / 29 / 27
49
4.89
3.26
5.00
6.00
A++
5.00
6.48
270
A++
4.36
4.29
1426
3.55 / 3.7
A/A
705
0.210 / 0.178 / 0.145
204 (264)
840 (950)
840 (950)
19 (24.4)
31 / 29 / 27
49
5.57
3.67
5.70
7.00
A++
5.70
6.22
321
A+
4.71
4.00
1646
3.48 / 3.52
A/B
820
0.227 / 0.187 / 0.145
204 (264)
840 (950)
840 (950)
19 (24.4)
33 / 31 / 28
51
RXS35L3
550 x 765 x 285
34
RXS50L
735 x 825 x 300
47
1ph
6.30
6.80
20
RXS60L
735 x 825 x 300
48
4.00
4.30
10
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
20
15
10
20
1.2
48 / 44
61
0.600
7.40
10.2
20
3+E / 1.5
1/4 (6.4) / 1/2 (12.7)
30
20
10
20
1.7
48 / 44
62
0.848
●
●
£683.00
£552.00
£1,235.00
£699.00
£694.00
£1,393.00
Accessories:
30
20
10
20
1.5
49 / 46
62
0.836
£743.00
£740.00
£1,483.00
Notes:
Accessory Ref
Description
Trade Price
BRC7FA532F
BYCQ140DG
BYCQ140DW
BRYQ140A
KDBHQ55B140
KDDQ55B140 1&2
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
K.CWB90-2
K.DT1
K.CGM
Wireless remote controller
Roundflow cassette decoration panel with self cleaning filter
Roundflow cassette decoration panel - white with white louvres
Integral PIR Sensor for Roundflow decoration panel. Enables Energy Saving functions
Sealing member for air discharge outlet
Fresh air intake kit for up to 20% fresh air - 2 part kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 42-71
£152.00
£310.00
£160.00
£99.00
£90.00
£233.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£54.00
£296.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7FA532F Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils suppled as standard with
BYCQ140D Decoration panel
v)BYCQ140DW / BYCQ140DG Trade prices
will be reduced by £142.00 if ordered in
place of standard decoration panel
vi)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
> FCQG is a compact cassette designed to suit installation in narrower ceiling voids
> The unique 360° radial air pattern ensures uniform air flow and temperature distribution
> Air flow flexibility: a wide selection of 23 different air flow patterns accessible via remote controller
> Optional Presence Sensors detects if room is unoccupied and allows temperature to drift to set-back levels
>Optional Self Cleaning Filter: The BYCQ140DG decoration panel can offer energy savings, reduced maintenance time and cost
> Suitable for Twin, Triple and Double Twin applications
> Re-use of existing R22 and R407C piping possible
> DIII net compatibility as standard
Price List 2016
31
SPLIT, SKY AIR HEAT PUMPS
FUQ-C / RZQG-L
Under Ceiling Cassette – Seasonal Smart
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
Dimensions
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
FUQ100C
FUQ125C
FUQ71C
FUQ100C
FUQ125C
mm
mm
mm
kg
dBA
dBA
7.76
5.32
6.80
7.50
A++
6.80
6.50
367
A+
7.60
4.20
2534
4.05 / 4.08
A/A
840
0.383 / 0.325 /
1.933
198
950
950
25
41 / 38 / 35
59
10.80
7.44
9.50
10.80
A++
9.50
6.11
545
A+
11.30
4.50
3516
3.86 / 3.95
A/A
1230
0.517 / 0.425 /
0.333
198
950
950
26
46 / 42 / 39
64
13.60
9.30
12.00
13.50
A+
12.00
5.61
749
A+
14.13
4.44
4456
3.39 / 3.42
A/A
1770
0.542 / 0.442 /
0.342
198
950
950
26
47 / 43 / 40
65
7.76
5.32
6.80
7.50
A++
6.80
6.50
367
A+
7.60
4.20
2534
4.05 / 4.08
A/A
840
0.383 / 0.325 /
1.933
198
950
950
25
41 / 38 / 35
59
10.80
7.44
9.50
10.80
A++
9.50
6.11
545
A+
11.30
4.50
3516
3.86 / 3.95
A/A
1230
0.517 / 0.425 /
0.333
198
950
950
26
46 / 42 / 39
64
13.60
9.30
12.00
13.50
A+
12.00
5.61
749
A+
14.13
4.44
4456
3.39 / 3.42
A/A
1770
0.542 / 0.442 /
0.342
198
950
950
26
47 / 43 / 40
65
RZQG71L9V1
RZQG100L9V1
RZQG125L9V1
RZQG71L8Y1
RZQG100L8Y1
RZQG125L8Y1
mm
kg
990 x 940 x 320
69
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
Nom
3 Phase
FUQ71C
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
1430 x 940 x 320
95
2.9
48 / 43
64
0.983
1ph
9.52
4
32
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
75
30
30
Refer to Installation Manual
4.0
50 / 45
66
1.166
●
●
£857.00
£1,191.00
£2,048.00
£940.00
£1,514.00
£2,454.00
6.83
4
20
50
30
30
990 x 940 x 320
80
14.06
4
32
2.57
4
16
75
30
30
50
30
30
4.0
51 / 45
67
1.166
2.9
48 / 43
64
0.983
3ph
3.58
4
20
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
75
30
30
Refer to Installation Manual
4.0
50 / 45
66
1.166
●
●
£857.00
£1,227.00
£2,084.00
£940.00
£1,584.00
£2,524.00
£1,037.00
£1,666.00
£2,703.00
Accessories:
5.29
4
20
75
30
30
4.0
51 / 45
67
1.166
£1,037.00
£1,743.00
£2,780.00
Notes:
Accessory Ref
Description
Trade Price
BRC7C58
EKRORO5
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
Wireless remote controller
Remote on/off control interface kit
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£29.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£46.00
£59.00
£296.00
£354.00
Features:
> The 4-way blow under ceiling cassettes are the ideal solution for rooms, shops or offices without false ceilings
> Seasonally Efficient Inverter Technology gives up to 25% better efficiency than inverter technology
>Air flow flexibility: air can be discharged in any of 4 directions. Possibility to shut off 1 or 2 flaps enabling the unit
to be installed in a corner or small room
> 3 step fan-speed
> Suitable for Twin, Triple and Double Twin applications
> Re-use of existing R22 and R407C piping possible
> Comms, computer and server room cooling possible with EDP setting
> Selectable evaporating & condensing temperature for greater operating efficiency
32
1430 x 940 x 320
101
Residential, Commercial and Industrial
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC7C58 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)Minimum ambient operating
temperatures:
RZQG
Cooling
Heating
-15°C
-20°C
FOR 2016
FUQ-C / RZQSG-L
Under Ceiling Cassette – Seasonal Classic
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Air Flow Rate (Cooling)
SPLIT, SKY AIR HEAT PUMPS
NEW
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Nom / Night Quiet
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
m3/Sec
3 Phase
FUQ71C
FUQ100C
FUQ125C
FUQ100C
FUQ125C
7.28
4.99
6.80
7.50
A+
6.80
5.81
410
A+
6.33
3.90
2273
3.21 / 3.61
A/A
TBC
0.383 / 0.325 / 0.193
10.80
7.44
9.50
10.80
A+
9.50
5.61
593
A+
7.60
4.01
2653
3.21 / 3.61
A/A
TBC
0.517 / 0.425 / 0.333
198
950
950
13.60
9.30
12.00
13.50
A
12.0
5.30
793
A
7.60
3.85
2763
2.65 / 3.41
D/B
TBC
0.542 / 0.442 / 0.342
10.80
7.44
9.50
10.80
A+
9.50
5.61
593
A+
7.60
4.01
2653
3.21 / 3.61
A/A
TBC
0.517 / 0.425 / 0.333
13.60
9.30
12.00
13.50
A
12.0
5.30
793
A
7.60
3.85
2763
2.65 / 3.41
D/B
TBC
0.542 / 0.442 / 0.342
198
950
950
26
25
41 / 38 / 35
59
46 / 42 / 39
64
47 / 43 / 40
65
46 / 42 / 39
64
47 / 43 / 40
65
RZQSG71L3V1
RZQSG100L9V1
RZQSG125L9V1
RZQSG100L8Y1
RZQSG125L8Y1
770 x 900 x 320
67
26
990 x 940 x 320
2.75
49 / 49
65
0.866
72
1ph
TBC
4
32
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
30
30
Refer to Installation Manual
2.9
53 / 49
70
1.266
2.9
54 / 49
70
1.283
£857.00
£820.00
£1,677.00
£940.00
£1,135.00
£2,075.00
£1,037.00
£1,345.00
£2,382.00
TBC
4
20
50
15
30
990 x 940 x 320
82
3ph
74
TBC
4
32
TBC
4
20
TBC
4
20
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
30
30
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53 / 49
54 / 49
70
70
1.266
1.283
£940.00
£1,170.00
£2,110.00
£1,037.00
£1,282.00
£2,319.00
Notes:
i)Minimum ambient operating
temperatures:
RZQSG
Cooling
Heating
-15°C
-15°C
Price List 2016
33
SPLIT, SKY AIR HEAT PUMPS
FFQ-C / RXS-L
600x600 Fully Flat Cassette
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
COOLING
SEER
Annual Energy Consumption
Seasonal Efficiency
Energy Label
(EN14825)
Pdesign
HEATING
SCOP
Annual Energy Consumption
Nominal Efficiency
EER / COP
Energy Label
Annual Energy Consumption
Air Flow Rate (Cooling)
High / Nom / Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate (Cooling)
High
mm
kg
White
Silver
FFQ25C
FFQ35C
FFQ50C
FFQ60C
2.44
1.81
2.50
3.20
A++
2.50
6.11
143
A+
2.31
4.24
763
4.53 / 3.9
A/A
276
0.150 / 0.133 / 0.108
260 (306)
575 (620)
575 (620)
16 (18.8)
31 / 28.5 / 25
48
3.32
2.28
3.40
4.00
A++
3.40
6.32
188
A+
3.10
4.10
1059
3.78 / 3.5
A/B
460
0.167 / 0.142 / 0.108
260 (306)
575 (620)
575 (620)
16 (18.8)
34 / 30.5 / 25
51
4.62
3.40
4.70
5.50
A+
5.00
5.93
295
A
3.84
3.90
1378
3.21 / 3.49
A/B
780
0.200 / 0.167 / 0.125
260 (306)
575 (620)
575 (620)
17.5 (20.2)
39 / 34 / 27
56
5.72
4.20
5.80
7.00
A+
5.70
5.71
349
A+
3.96
4.04
1373
3.02 / 3.41
B/B
945
0.242 / 0.208 / 0.158
260 (306)
575 (620)
575 (620)
17.5 (20.2)
43 / 40 / 32
60
RXS25L3
RXS35L3
RXS50L
RXS60L
550 x 765 x 285
34
550 x 765 x 285
34
735 x 825 x 300
47
735 x 825 x 300
48
4.00
3.3
10
4.00
4.3
10
6.90
6.8
20
8.30
10.2
20
1ph
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
ECA Eligible
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
3+E / 1.5
1/4 (6.4) / 1/2 (12.7)
20
15
10
20
15
10
1.0
46 / 43
61
0.588
1.2
48 / 44
61
0.600
30
20
10
30
20
10
1.7
48 / 44
62
0.848
1.5
49 / 46
62
0.836
£766.00
£694.00
£1,460.00
£809.00
£740.00
£1,549.00
20
●
●
£636.00
£476.00
£1,112.00
£696.00
£552.00
£1,248.00
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BYFQ60CW
BYFQ60CS
BYFQ60B3
BRYQ60AW
BRYQ60AS
BRC7F530W
BRC7F530S
BRC7EB530W
BDBHQ44C60
KRP4A53/UK.FB2
KRP1B57/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
K.CWB90-2
K.DT1
K.CGS
K.CGM
Fully Flat Cassette Decoration Panel - White
Fully Flat Cassette Decoration Panel - Sliver
Fully Flat Cassette Decoration Panel - Old Style (FFQ-B9V looks)
Integral PIR Sensor for Fully Flat cassette White decoration panel. Enables Energy Saving functions
Integral PIR Sensor for Fully Flat Cassette Silver decoration panel. Enables Energy Saving functions
Wireless remote controller for White Ceiling Decoration Panel
Wireless remote controller for Silver Ceiling Decoration Panel
Wireless remote for Fully Flat Cassette Old Style Decoration Panel
Sealing member for decoration panel-FFQ, FXZQ
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Adaptor PCB for Interlock to fresh air fan
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£198.00
£198.00
£198.00
£99.00
£99.00
£152.00
£152.00
£152.00
£91.00
£92.00
£100.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£37.00
£54.00
£214.00
£296.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)Infrared remote Trade price will be
reduced by £76.00 if ordered instead of
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils suppled as standard
with BYFQ60CW White fully flat
decoration panel
v)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
Features:
> Installed into suspended ceiling grids without cutting surrounding tiles
> Home Leave setting maintains pre-set temperature during periods of extended absence
> Dry programme: Daikin’s special dry programme reduces humidity in the rooms without variations in internal temperature
> Vertical auto-swing function: flaps automatically swing up and down to ensure efficient air and temperature distribution which also prevents ceiling soiling
> 3 fan speeds can be selected: high, medium and low
> Suitable for Twin, Triple and Double Twin applications. Also suitable for multi model applications
> Re-use of existing R22 and R407C piping possible
34
Residential, Commercial and Industrial
SPLIT, SKY AIR HEAT PUMPS
FBQ-D & FDXS-F / RXS-L
Built in DC Ducted & Slim Concealed Ceiling Unit
Indoor Units
DC Ducted
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
External Static Pressure
Dimensions
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
High / Nom
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
FBQ50D
FBQ60D
FDXS25F
FDXS35F
FDXS50F9
FDXS60F
3.32
2.93
3.40
4.00
A++
3.40
6.17
193
A+
2.90
4.07
998
3.99 / 4.02
A/A
426
0.250 / 0.208 /
0.175
4.89
3.55
5.00
5.50
A++
5.00
6.21
282
A+
4.40
4.06
1517
3.52 / 3.83
B/A
710
0.250 / 0.208 /
0.175
150 / 30
245
5.57
4.09
5.70
7.00
A+
5.70
5.86
340
A+
4.60
4.01
1606
3.45 / 3.71
B/A
826
0.300 / 0.250 /
0.208
2.35
1.81
2.40
3.20
A+
2.40
5.63
149
A+
2.60
4.24
858
3.74 / 4.00
A/A
325
0.145 / 0.145 /
0.122
30.0
3.32
2.26
3.40
4.00
A
3.40
5.21
228
A
2.90
3.88
1047
2.96 / 3.48
A/B
574
0.145 / 0.145 /
0.122
30.0
4.81
3.08
5.00
5.80
A+
5.00
5.72
306
A
4.00
3.93
1425
3.03 / 3.1
B/D
825
0.200 / 0.200 /
0.167
40.0
5.86
3.97
6.00
7.00
A
6.00
5.51
381
A
4.60
3.80
1693
2.91 / 3.21
C/C
1030
0.267 / 0.000 /
0.225
40.0
Pa
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) High / Silent Operation
Sound Power
Air Flow Rate (Cooling)
High
Slim Ducted
FBQ35D
700
200
1000
28
620
35 / 32 / 29
60
35 / 32 / 29
60
35
30 / 28 / 25
55
RXS35L3
RXS50L
RXS60L
550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
34
47
48
1ph (refer to databook)
A
4.6
7.2
9.2
A
4.3
6.8
10.2
A
10
20
20
3+E / 1.5
3+E / 1.5
inches (mm) 1/4 (6.4) / 3/8 (9.5)
1/4 (6.4) / 1/2 (12.7)
m
20
30
30
m
15
20
20
m
10
10
10
g/m
20
kg
1.2
1.7
1.5
dBA
48 / 44
48 / 44
49 / 46
dBA
61
61
62
m3/sec
0.600
0.848
0.836
£515.00
£552.00
£1,067.00
£541.00
£694.00
£1,235.00
21
30
35 / 33 / 27
53
35 / 33 / 27
53
38 / 36 / 30
55
38 / 36 / 30
56
RXS25L3
RXS35L3
RXS50L
RXS60L
550 x 765 x 285
34
£600.00
£740.00
£1,340.00
550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
34
47
48
1ph
3.90
4.90
7.10
9.20
3.3
4.3
6.8
10.2
10
10
20
20
3+E / 1.5
3+E / 1.5
1/4 (6.4) / 3/8 (9.5)
1/4 (6.4) / 1/2 (12.7)
20
20
30
30
15
15
20
20
10
10
10
10
20
1.0
1.2
1.7
1.5
46 / 43
48 / 44
48 / 44
49 / 46
59
61
61
62
0.558
0.600
0.484
0.836
£394.00
£476.00
£870.00
Accessories:
£441.00
£552.00
£993.00
£477.00
£694.00
£1,171.00
£524.00
£740.00
£1,264.00
Notes:
Accessory Ref
Description
Trade Price
BRC4C65
BRC2E52
Wireless remote controller
Wired Simplified remote controller
Recessed simplified remote (see page 100 for options)
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air & VRV. Duty rotation, Lead Lag control & heating interlock
Energy control PCB for Sky Air and VRV
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Supply air plenum for FBQ35D / FBQ50D (2 x 200mm spigots)
Supply air plenum for FBQ60D (2 x 200 spigots)
Supply air plenum for FBQ60D (3 x 200 spigots)
Supply air plenum for FDXS25/35F (2 x 150mm spigots
Supply air plenum for FDXS50F9 (3 x 150mm spigots)
Supply air plenum for FXDS60F (4 x 150mm spigots)
Return air plenum for FBQ35D / FBQ50D (2 x 200mm spigots)
Return air plenum for FBQ60D (2 x 200 spigots)
Return air plenum for FBQ60D (3 x 200 spigots)
Return air plenum for FDXS25/35F (2 x 150mm spigots
Return air plenum for FDXS50F9 (3 x 150mm spigots)
Return air plenum for FXDS60F (4 x 150mm spigots)
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensing Unit Guard size 20-35
Condensing Unit Guard size 42-71
£152.00
£80.00
£180.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£72.00
£79.00
£84.00
£67.00
£73.00
£85.00
£79.00
£86.00
£93.00
£76.00
£83.00
£97.00
£37.00
£54.00
£214.00
£296.00
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4B
K.RSS
RS-SE
UK.SF2
UK.SF3
UK.SF3A
UK.SAF5
UK.SF6
UK.SAF7
UK.RC2
UK.RC3
UK.RC3A
UK.RAC5
UK.RC6
UK.RAC7
K.CWB90-2
K.DT1
K.CGS
K.CGM
1150
800
mm
kg
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
750
i)FBQ & FDXS fan coils supplied as standard
with BRC1E52A wired remote controller
with 7-day time clock
ii)BRC4C65 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils supplied as standard with
air filter
v)Minimum ambient operating
temperatures:
RXS
Cooling
Heating
-10°C
-15°C
vi)The FBQ35D fan coil requires a separate
1ph power supply. Refer to install manual
for details
Features:
> Fan speed: 5 fan speeds can be selected, high to super low
> Connection to multi outdoor possible
> Re-use of existing R22 and R407C piping possible
Price List 2016
35
SPLIT, SKY AIR HEAT PUMPS
FBQ-D / RZQG-L
Built in DC Ducted – Seasonal Smart
Indoor Units
Single Phase
FBQ71D
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
External Static Pressure
Dimensions
3 Phase
FBQ125D
FBQ140D
FBQ71D
FBQ140D
High / Nom
Height
Width
Depth
Pa
mm
mm
mm
kg
dBA
dBA
7.76
10.80
13.60
14.90
7.76
10.80
13.60
14.90
5.32
7.44
9.30
10.25
5.32
7.44
9.30
10.25
6.80
9.50
12.00
13.40
6.80
9.50
12.00
13.40
7.50
10.80
13.50
15.50
7.50
10.80
13.50
15.50
A++
A+
A++
A++
A+
A++
6.80
9.50
12.00
6.80
9.50
12.00
6.16
5.87
6.11
6.16
5.87
6.11
386
566
687
386
566
687
A+
A++
A+
A+
A++
A+
6.00
11.30
12.70
6.00
11.30
12.71
4.31
4.78
4.28
4.31
4.78
4.28
1949
3310
4154
1949
3310
4154
3.60 / 4.01
3.81 / 4.41
3.31 / 3.90
3.35 / 3.60
3.60 / 4.01
3.81 / 4.41
3.31 / 3.90
3.35 / 3.60
A/A
A/A
A/A
A/B
A/A
A/A
A/A
A/B
944
1217
1813
2000
944
1217
1813
2000
0.300 / 0.250 / 0.483 / 0.433 / 0.567 / 0.483 / 0.567 / 0.483 / 0.300 / 0.250 / 0.483 / 0.433 / 0.567 / 0.483 / 0.567 / 0.483 /
0.208
0.383
0.392
0.393
0.208
0.383
0.392
0.393
150 / 30
150 / 40
150 / 50
150 / 30
150 / 40
150 / 50
245
245
1000
1400
1000
1400
800
800
35
46
35
46
30 / 28 / 25
34 / 32 / 30
37 / 35 / 32
30 / 28 / 25
34 / 32 / 30
37 / 35 / 32
56
58
62
62
56
58
62
62
mm
kg
990 x 940 x 320
69
kW
kWh
kW
kWh
kWh
m3/sec
RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
High
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
ECA Eligible
7.93
4
20
50
30
30
2.9
48 / 43
64
0.983
1430 x 940 x 320
95
1ph
9.97
12.87
4
4
32
32
3+E / 1.5
3/8 ( 9.5) / 5/8 (15.9)
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50 / 45
51 / 45
66
67
1.166
1.166
95
●
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
£860.00
£1,191.00
£2,051.00
95
990 x 940 x 320
80
16.43
4
32
2.98
4
16
75
30
30
50
30
30
4.0
52 / 45
69
1.400
2.9
48 / 43
64
0.983
£1,232.00
£1,901.00
£3,133.00
£860.00
£1,227.00
£2,087.00
●
£899.00
£1,514.00
£2,413.00
£1,063.00
£1,666.00
£2,729.00
1430 x 940 x 320
101
3ph
3.75
4.84
4
4
20
20
3+E / 1.5
3/8 ( 9.5) / 5/8 (15.9)
75
75
30
30
30
30
Refer to Installation Manual
4.0
4.0
50 / 45
51 / 45
66
67
1.166
1.166
●
Accessories:
6.18
4
20
75
30
30
4.0
52 / 45
69
1.400
●
£899.00
£1,584.00
£2,483.00
£1,063.00
£1,743.00
£2,806.00
£1,232.00
£2,002.00
£3,234.00
Notes:
Accessory Ref
Description
Trade Price
BRC4C65
BRC2E52
Wireless remote controller
Wired Simplified remote controller (without auto swing)
Recessed simplified remote (see page 100 for options)
Unit/Group adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Enhanced function PCB for Sky Air and VRV. Duty rotation, Lead Lag control and heating interlock.
Energy control PCB for Sky Air and VRV.
KNX Interface for Sky Air and VRV systems
Remote room mounted temperature sensor
Wireless room mounted temperature sensor and receiver
Service and Configuration Tool for K.RSS
Supply air plenum for FBQ71D (2 x 200 spigots)
Supply air plenum for FBQ71D (3 x 200 spigots)
Supply air plenum for FBQ100 - 140D (4 x 200mm spigots)
Return air plenum for FBQ71D (2 x 200 spigots)
Return air plenum for FBQ71D (3 x 200 spigots)
Return air plenum for FBQ100 - 140D (4 x 200mm spigots)
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£152.00
£80.00
£180.00
£92.00
£190.00
£235.00
£251.00
£185.00
£42.00
£89.00
£93.00
£79.00
£84.00
£104.00
£86.00
£93.00
£116.00
£37.00
£46.00
£59.00
£296.00
£354.00
i)All fan coils supplied as standard with
BRC1E52A wired remote controller with
7-day time clock
ii)BRC4C65 Trade price will be reduced
by £76.00 if ordered in place of the
BRC1E52A
iii)All fan coil units standard with auto restart
after power failure
iv)All fan coils supplied as standard with
air filter
v)Minimum ambient operating
temperatures:
RZQG
RZQSG
Features:
> New chassis with height of 245mm makes the FBQ-D one of the slimmest medium static ducted units on the market
> Increased external static pressure up to 150 Pa
> Flexibility to set the required fan curve manually or to automatically select the correct fan curve, assuring comfort at all times
> Top efficiency, highest Energy label ranking in the market
36
FBQ125D
kW
kW
kW
kW
Outdoor Units
KRP4A53/UK.FB2
RTD-NET/UK.FB2
RTD-10/UK.FB2
RTD-20/UK.FB2
KLIC-DI
KRCS01-4
K.RSS
RS-SE
UK.SF3
UK.SF3A
UK.SF4
UK.RC3
UK.RC3A
UK.RC4
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
FBQ100D
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
Dimensions
Weight
Electrical Details
FBQ100D
Residential, Commercial and Industrial
Cooling
Heating
-15°C
-15°C
-20°C
-15°C
SPLIT, SKY AIR HEAT PUMPS
FBQ-D / RZQSG-L
Built in DC Ducted – Seasonal Classic
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate (Cooling)
External Static Pressure
Dimensions
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Nom / Low
High / Nom
Height
Width
Depth
Weight
Sound Pressure (Cooling) High / Nom / Low
Sound Power
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/sec
Pa
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
FBQ71D
FBQ100D
7.28
4.99
6.80
7.50
A+
6.80
5.84
408
A+
6.00
4.01
2095
3.43 / 3.92
A/A
991
0.300 / 0.250 /
0.208
150 / 30
10.80
7.44
9.50
10.80
A+
9.50
5.61
593
A+
7.60
4.15
2564
3.35 / 3.67
A/A
1418
0.483 / 0.433 /
0.383
150 / 40
3 Phase
FBQ125D
FBQ140D
13.60
14.90
9.30
10.25
12.00
13.40
13.50
15.50
A
12.00
5.47
768
A+
7.60
4.01
2653
3.23 / 3.63
3.06 / 3.40
A/A
B/B
1858
2190
0.567 / 0.483 /
0.567 / 0.483 /
0.392
0.393
150 / 50
FBQ100D
10.80
7.44
9.50
10.80
A+
9.50
5.61
593.00
A+
7.60
4.15
2564
3.35 / 3.67
A/A
1418
0.483 / 0.433 /
0.383
150 / 40
245
1000
1400
800
35
30 / 28 / 25
56
46
34 / 32 / 30
58
37 / 35 / 32
62
62
34 / 32 / 30
58
FBQ125D
FBQ140D
13.60
14.90
9.30
10.25
12.00
13.40
13.50
15.50
A
12.00
5.47
768.00
A+
7.60
4.01
2653
3.23 / 3.63
3.06 / 3.40
A/A
B/B
1858
2190
0.567 / 0.483 /
0.567 / 0.483 /
0.392
0.393
150 / 50
245
1400
800
46
37 / 35 / 32
62
RZQSG71L3V1 RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1 RZQSG140LY1
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
High
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
dBA
m3/sec
770 x 900 x 320
72
8.46
4
20
50
15
30
2.75
49 / 49
65
0.866
£860.00
£820.00
£1,680.00
990 x 940 x 320
75
1ph
11.73
15.29
4
4
32
32
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
50
30
30
30
30
Refer to Installation Manual
2.9
2.9
53 / 49
54 / 49
70
70
1.266
1.283
£899.00
£1,135.00
£2,034.00
£1,063.00
£1,245.00
£2,308.00
1430 x 940 x 320
95
18.15
4
32
50
30
30
4.0
53 / 49
69
1.383
£1,232.00
£1,386.00
£2,618.00
990 x 940 x 320
1430 x 940 x 320
82
101
3ph
4.39
5.72
6.79
4
4
4
20
20
20
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
50
50
30
30
30
30
30
30
Refer to Installation Manual
2.9
2.9
4.0
53 / 49
54 / 49
53 / 49
70
70
69
1.266
1.283
1.383
£899.00
£1,170.00
£2,069.00
£1,063.00
£1,282.00
£2,345.00
£1,232.00
£1,428.00
£2,660.00
Price List 2016
37
SPLIT, SKY AIR HEAT PUMPS
ABQ-C / AZQS
Concealed Ceiling Unit
Indoor Units
Capacity
Seasonal Efficiency
(EN14825)
COOLING
Seasonal Efficiency
(EN14825)
HEATING
Nominal Efficiency
Air Flow Rate
External Static Pressure
Dimensions
Weight
Sound Pressure
Sound Power
Single Phase
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Energy Label
Pdesign
SEER
Annual Energy Consumption
Energy Label
Pdesign
SCOP
Annual Energy Consumption
EER / COP
Energy Label
Annual Energy Consumption
High / Low
High / Nominal
Height
Width
Depth
High / Low
kW
kW
kW
kW
kW
kWh
kW
kWh
kWh
m3/min
Pa
mm
mm
mm
kg
dBA
dBA
Outdoor Units
Dimensions
Weight
Electrical Details
Interconnection Wiring
Piping Connections
Pipework
Sound Pressure
Sound Power
Height x Width x Depth
Power Supply
Running Current
Starting Current
Max Fuse Size
Core / Cable size
Liquid / Gas
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
High
mm
kg
A
A
A
inches
m
m
m
g/m
kg
dBA
dBA
Trade Fan Coil Price
Trade Condensing Unit Price
Total System Price
3 Phase
ABQ71C
ABQ100C
ABQ125C
ABQ140C
ABQ100C
ABQ125C
ABQ140C
7.28
4.99
6.80
7.50
B
6.80
4.65
512
A
5.65
3.80
2082
2.91 / 3.51
C/B
1165
18.3 / 15.4
90 / 70
285
1007
600
35
64
10.80
7.44
9.50
10.80
B
9.50
4.65
716
A
6.78
3.80
2498
2.62 / 3.42
D/B
1813
22.7 / 18.3
70 / 57
378
1045
541
44
41 / 36
60
13.60
9.30
12.10
13.50
2.81 / 3.41
C/B
2153
40.5 / 34.8
150 / 128
378
1299
541
50
53 / 50
-
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159
48.7 / 37.9
150 / 122
378
1499
541
56
55 / 50
-
10.80
7.44
9.50
10.80
B
9.50
4.65
716.00
A
6.78
3.80
2498.00
2.62 / 3.42
D/B
1813
22.7 / 18.3
70 / 57
378
1045
541
44
41 / 36
60
13.60
9.30
12.10
13.50
2.81 / 3.41
C/B
2153
40.5 / 34.8
150 / 128
378
1299
541
50
53 / 50
-
14.90
10.25
13.00
15.50
3.01 / 3.41
B/B
2159
48.7 / 37.9
150 / 122
378
1499
541
56
55 / 50
-
AZQS71BV1
AZQS100B8V1
AZQS125B8V1
AZQS140B8V1
AZQS100BY1
AZQS125BY1
770x900x320
67
990x940x320
data-book
48
64
73
74
1~ / 50 / 220 - 240
14.84
17.57
4
4
32
32
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
30
30
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£623.00
£714.00
£1,337.00
£812.00
£878.00
£1,690.00
9.52
4
20
3/8 / 5/8
30
30
30
£926.00
£986.00
£1,912.00
1430x940x320
95
data-book
53
70
990x940x320
81
3~ / 50 / 400
4.93
5.84
4
4
16
20
3+E / 1.5
3/8 / 5/8
3/8 / 5/8
30
30
30
30
30
30
data-book
data-book
data-book
53
54
70
71
£969.00
£1,104.00
£2,073.00
£812.00
£926.00
£1,738.00
17.66
4
40
3/8 / 5/8
30
30
30
Accessories:
5.87
4
25
3/8 / 5/8
30
30
30
data-book
53
70
£969.00
£1,164.00
£2,133.00
Notes:
Accessory Ref
Description
Trade Price
R04084124324
K.CWB90-2
K.CWB140-2
K.DT1
K.DT2
K.CGM
K.CGL
PCB Adaptor for group control (1 per fan-coil)
Condensing unit bracket - up to size 71
Condensing unit bracket - sizes 100 to 140
Condensate drip tray for use with K.CWB90-2
Condensate drip tray for use with K.CWB140-2
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£82.00
£36.00
£46.00
£54.00
£59.00
£296.00
£354.00
Features:
> 7 day timer as standard
> Hard wired remote ARCWB as standard
> Ideal for shops / restaurants with ceiling voids
> High external static pressures for long duct runs
i)Fan-coils supplied with ARCWB hard
wired remote
ii)Replacement Technology not applicable
to AZQS
iii)All fan coil units standard with auto restart
after power failure
iv)Fan-coils supplied as standard with
air filter
v)Minimum ambient operating
temperature:
AZQS
WHOLESALE
EXCLUSIVE
38
£926.00
£1,038.00
£1,964.00
AZQS140BY1
1430x940x320
101
Residential, Commercial and Industrial
Cooling
Heating
-5°C
-15°C
Indoor
Model
Smart Single Phase
Hi-COP Cassette
Smart Three Phase
Smart Single Phase
Smart Three Phase
Classic Single Phase
Roundflow
Classic Three Phase
Inverter Single Phase
Inverter Three Phase
RXS
Smart Single Phase
Smart Three Phase
Under Ceiling Cassette (FUQ)
Classic Single Phase
Classic Three Phase
Fully Flat Cassette (FFQ)
RXS
Smart Single Phase
Smart Three Phase
Ducted
Classic Single Phase
Classic Three Phase
RXS
Slim Ducted
High Static Ducted
RXS
Smart Single Phase
Smart Three Phase
Classic Single Phase
Classic Three Phase
RZQ-C
Capacity
Order Code
Product Codes Included
List Price
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
10.0kW
12.5kW
14.0kW
3.5kW
5.0kW
6.0kW
7.1kW
10.0kW
12.5kW
7.1kW
10.0kW
12.5kW
7.1kW
10.0kW
12.5kW
10.0kW
12.5kW
2.5kW
3.5kW
5.0kW
6.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
7.1kW
10.0kW
12.5kW
14.0kW
10.0kW
12.5kW
14.0kW
3.5kW
5.0kW
6.0kW
2.5kW
3.5kW
5.0kW
6.0kW
12.5kW
12.5kW
12.5kW
12.5kW
20kW
25kW
SB.FCQHG71F_FP/GLY
SB.FCQHG100F_FP/GLY
SB.FCQHG125F_FP/GLY
SB.FCQHG140F_FP/GLY
SB.FCQHG71F_FP/GLY
SB.FCQHG100F_FP/GLY
SB.FCQHG125F_FP/GLY
SB.FCQHG140F_FP/GLY
SB.FCQG71F_FP/GLV
SB.FCQG100F_FP/GLV
SB.FCQG125F_FP/GLV
SB.FCQG140F_FP/GLV
SB.FCQG71F_FP/GLY
SB.FCQG100F_FP/GLY
SB.FCQG125F_FP/GLY
SB.FCQG140F_FP/GLY
SB.FCQG71F_FP/SLV
SB.FCQG100F_FP/SLV
SB.FCQG125F_FP/SLV
SB.FCQG140F_FP/SLV
SB.FCQG100F_FP/SLY
SB.FCQG125F_FP/SLY
SB.FCQG140F_FP/SLY
SB.FCQG71F_FP/AZQSV
SB.FCQG100F_FP/AZQSV
SB.FCQG125F_FP/AZQSV
SB.FCQG140F_FP/AZQSV
SB.FCQG100F_FP/AZQSY
SB.FCQG125F_FP/AZQSY
SB.FCQG140F_FP/AZQSY
SB.FCQG35F_FP/RXSL3
SB.FCQG50F_FP/RXSL
SB.FCQG60F_FP/RXSL
SB.FUQ71C_F/GLV
SB.FUQ100C_F/GLV
SB.FUQ125C_F/GLV
SB.FUQ71C_F/GLY
SB.FUQ100C_F/GLY
SB.FUQ125C_F/GLY
SB.FUQ71C_F/SLV
SB.FUQ100C_F/SLV
SB.FUQ125C_F/SLV
SB.FUQ100C_F/SLY
SB.FUQ125C_F/SLY
SB.FFQ25C_F/RXSL3
SB.FFQ35C_F/RXSL3
SB.FFQ5OC_F/RXSL
SB.FFQ60C_F/RXSL
SB.FBQ71D_F/GLV
SB.FBQ100D_F/GLV
SB.FBQ125D_F/GLV
SB.FBQ140D_F/GLV
SB.FBQ71D_F/GLY
SB.FBQ100D_F/GLY
SB.FBQ125D_F/GLY
SB.FBQ140D_F/GLY
SB.FBQ71D_F/SLV
SB.FBQ100D_F/SLV
SB.FBQ125D_F/SLV
SB.FBQ140D_F/SLV
SB.FBQ100D_F/SLY
SB.FBQ125D_F/SLY
SB.FBQ140D_F/SLY
SB.FBQ35D_F/RXSL3
SB.FBQ5OD_F/RXSL
SB.FBQ60D_F/RXSL
SB.FDXS25F_F/RXSL3
SB.FDXS35F_F/RXSL3
SB.FDXS5OF9_F/RXSL
SB.FDXS60F_F/RXSL
SB.FDQ125C_F/GLV
SB.FDQ125C_F/GLY
SB.FDQ125C_F/SLV
SB.FDQ125C_F/SLY
SB.FDQ200B_F/RZQ
SB.FDQ250B_F/RZQ
BRC1E52A+BYCQ140D+FCQHG71F+RZQG71L9V1
BRC1E52A+BYCQ140D+FCQHG100F+RZQG100L9V1
BRC1E52A+BYCQ140D+FCQHG125F+RZQG125L9V1
BRC1E52A+BYCQ140D+FCQHG140F+RZQG140L9V1
BRC1E52A+BYCQ140D+FCQHG71F+RZQG71L8Y1
BRC1E52A+BYCQ140D+FCQHG100F+RZQG100L8Y1
BRC1E52A+BYCQ140D+FCQHG125F+RZQG125L8Y1
BRC1E52A+BYCQ140D+FCQHG140F+RZQG140LY1
BRC1E52A+BYCQ140D+FCQG71F+RZQG71L9V1
BRC1E52A+BYCQ140D+FCQG100F+RZQG100L9V1
BRC1E52A+BYCQ140D+FCQG125F+RZQG125L9V1
BRC1E52A+BYCQ140D+FCQG140F+RZQG140L9V1
BRC1E52A+BYCQ140D+FCQG71F+RZQG71L8Y1
BRC1E52A+BYCQ140D+FCQG100F+RZQG100L8Y1
BRC1E52A+BYCQ140D+FCQG125F+RZQG125L8Y1
BRC1E52A+BYCQ140D+FCQG140F+RZQG140LY1
BRC1E52A+BYCQ140D+FCQG71F+RZQSG71L3V1
BRC1E52A+BYCQ140D+FCQG100F+RZQSG100L9V1
BRC1E52A+BYCQ140D+FCQG125F+RZQSG125L9V1
BRC1E52A+BYCQ140D+FCQG140F+RZQSG140L9V1
BRC1E52A+BYCQ140D+FCQG100F+RZQSG100L8Y1
BRC1E52A+BYCQ140D+FCQG125F+RZQSG125L8Y1
BRC1E52A+BYCQ140D+FCQG140F+RZQSG140LY1
BRC1E52A+BYCQ140D+FCQG71F+AZQS71L8V1
BRC1E52A+BYCQ140D+FCQG100F+AZQS100L8V1
BRC1E52A+BYCQ140D+FCQG125F+AZQS125L8V1
BRC1E52A+BYCQ140D+FCQG140F+AZQS140L8V1
BRC1E52A+BYCQ140D+FCQG100F+AZQS100LY1
BRC1E52A+BYCQ140D+FCQG125F+AZQS125LY1
BRC1E52A+BYCQ140D+FCQG140F+AZQS140LY1
BRC1E52A+BYCQ140D+FCQG35F+RXS35L3
BRC1E52A+BYCQ140D+FCQG50F+RXS50L
BRC1E52A+1-BYCQ140D+1-FCQG60F+1-RXS60L+1
BRC1E52A+1 -FUQ71C+1-RZQG71L9V1+1
BRC1E52A+1 -FUQ100C+1-RZQG100L9V1+1
BRC1E52A+1 -FUQ125C+1-RZQG125L9V1+1
BRC1E52A+1 -FUQ71C+1-RZQG71L8Y1+1
BRC1E52A+1-FUQ100C+1-RZQG100L8Y1+1
BRC1E52A+1 -FUQ125C+1-RZQG125L8Y1+1
BRC1E52A+1 -FUQ71C+1-RZQSG71L9V1+1
BRC1E52A+1 -FUQ100C+1-RZQSG100L9V1+1
BRC1E52A+1-FUQ125C+1-RZQSG125L9V1+1
BRC1E52A+1-FUQ100C+1-RZQSG100L8Y1+1
BRC1E52A+1 -FUQ125C+1-RZQSG125L8Y1+1
BRC1E52A x 1 & BYFQ60CW x 1 & FFQ25C x 1 & RXS35L3 x 1
BRC1E52A x 1 & BYFQ60CW x 1 & FFQ35C x 1 & RXS35L3 x 1
BRC1E52A x 1 & BYFQ60CW x 1 & FFQ50C x 1 & RXS50L x 1
BRC1E52A x 1 & & BYFQ60CW x 1 FFQ60C x 1 & RXS60L x 1
BRC1E52A x 1 & FBQ71D x 1 & RZQG71L9V1 x 1
BRC1E52A x 1 & FBQ100D x 1 & RZQG100L9V1 x 1
BRC1E52A x 1 & FBQ125D x 1 & RZQG125L9V1 x 1
BRC1E52A x 1 & FBQ140D x 1 & RZQG140L9V1 x 1
BRC1E52A x 1 & FBQ71D x 1 & RZQG71L8Y1 x 1
BRC1E52A x 1 & FBQ100D x 1 & RZQG100L8Y1 x 1
BRC1E52A x 1 & FBQ125D x 1 & RZQG125L8Y1 x 1
BRC1E52A x 1 & FBQ140D x 1 & RZQG140LY1 x 1
BRC1E52A x 1 & FBQ71D x 1 & RZQSG71L3V1 x 1
BRC1E52A x 1 & FBQ100D x 1 & RZQSG100L9V1 x 1
BRC1E52A x 1 & FBQ125D x 1 & RZQSG125L9V1 x 1
BRC1E52A x 1 & FBQ125D x 1 & RZQSG125L9V1 x 1
BRC1E52A x 1 & FBQ100D x 1 & RZQSG100L8Y1 x 1
BRC1E52A x 1 & FBQ125D x 1 & RZQSG125L8Y1 x 1
BRC1E52A x 1 & FBQ140D x 1 & RZQSG140LY1 x 1
BRC1E52A x 1 & FBQ35D x 1 & RXS35L3 x 1
BRC1E52A x 1 & FBQ50D x 1 & RXS50L x 1
BRC1E52A x 1 & FBQ60D x 1 & RXS60L x 1
BRC1E52A x 1 & FDXS25F x 1 & RXS35L3 x 1
BRC1E52A x 1 & FDXS35F x 1 & RXS35L3 x 1
BRC1E52A x 1 & FDXS50F9 x 1 & RXS50L x 1
BRC1E52A x 1 & FDXS60F x 1 & RXS60L x 1
BRC1E52A x 1 & FDQ125C x 1 & RZQG125L9V1 x 1
BRC1E52A x 1 & FDQ125C x 1 & RZQG125L8Y1 x 1
BRC1E52A x 1 & FDQ125C x 1 & RZQSG125L9V1 x 1
BRC1E52A x 1 & FDQ125C x 1 & RZQSG125L8Y1 x 1
BRC1E52A+1-FDQ200B+1-RZQ200C+1
BRC1E52A+1-FDQ250B+1-RZQ250C+1
£1,978.00
£2,404.00
£2,638.00
£3,069.00
£2,014.00
£2,474.00
£2,715.00
£3,170.00
£1,978.00
£2,404.00
£2,638.00
£3,069.00
£2,014.00
£2,474.00
£2,715.00
£3,170.00
£1,607.00
£2,025.00
£2,217.00
£2,554.00
£2,060.00
£2,254.00
£2,596.00
£1,501.00
£1,768.00
£1,958.00
£2,272.00
£1,816.00
£2,010.00
£2,332.00
£1,235.00
£1,393.00
£1,483.00
£2,048.00
£2,454.00
£2,703.00
£2,084.00
£2,524.00
£2,780.00
£1,677.00
£2,075.00
£2,382.00
£2,110.00
£2,319.00
£1,112.00
£1,248.00
£1,460.00
£1,549.00
£2,051.00
£2,413.00
£2,729.00
£3,133.00
£2,087.00
£2,483.00
£2,806.00
£3,234.00
£1,680.00
£2,034.00
£2,308.00
£2,618.00
£2,069.00
£2,345.00
£2,660.00
£1,067.00
£1,235.00
£1,340.00
£870.00
£993.00
£1,171.00
£1,264.00
£2,829.00
£2,906.00
£2,408.00
£2,445.00
£3,809.00
£4,345.00
Price List 2016
39
SPLIT, SKY AIR HEAT PUMPS
To simplify the order process, you may want to use the Order Code from table below.
Each code includes all products for a system (eg remote controllers, indoor units) & means you no longer need to order individual materials.
SPLIT, SKY AIR HEAT PUMPS
I
W I- F O L
TR
CO N A P P
V IA
Multi Series
Multi Series Inverters offer the ability to connect up to five fan coils to one
outdoor unit. With the MXS range it is possible to install indoor units throughout
a house or small commercial premises and only use one outdoor unit. Each indoor
unit will have its own controller and will be able to operate in heating or cooling.
Heating & cooling
Connectable
Indoor Units
Wall mounted
FTXG-L
CTXS-K
Floor standing
FTXS-K
FTXS-G FTX-KV
FVXG-K
FVXS-F
Flexi type
Roundflow
cassette
Fully flat
cassette
FLXS-B(9)
FCQG-F
FFQ-C
Concealed ceiling
FDXS-F(9)
Ceiling
Concealed
suspended floor standing
FDBQ-B/FBQ-D
FHQ-C
FNQ-A
20 25 35 50 15 35 20 25 35 42 50 60 71 20 25 35 25 35 50 25 35 50 25 35 50 60 35 50 60 25 35 50 60 25 35 50 60 25 35 50 60 35 50 60 25 35 50 60
2MXS40H
2MXS50H
3MXS40K
3MXS52E
3MXS68G
4MXS68F
4MXS80E
5MXS90E
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Daikin’s new Multi Selection Tool is a fast and simple way to select your combinations for MXS Series outdoor units.
The online tool has four simple steps:
> select number of rooms
> select capacity per room
> select capacity of outdoor
> select type of indoor & input pipe run & level difference
It has in-built checks to ensure capacity, pipe length and level difference cannot exceed maximum for selected outdoor
unit and generates a report showing full energy label for specific combination and pictures of all equipment selected.
This can be used by installers to select Multi systems, and also to show end-users the configuration of the system.
Go to www.daikineurope.com/multiselection
Multi Split & Mini VRV Fan Coils
Emura Wall Mounted Fan Coil Units
Trade Fan Coil Unit Price
FTXG20LW FTXG25LW FTXG35LW FTXG50LW FTXG20LS FTXG25LS FTXG35LS FTXG50LS
£262.00
£276.00
£310.00
£409.00
£313.00
£329.00
£369.00
£488.00
Wall Mounted Standard Inverter Fan Coil Units
Trade Fan Coil Unit Price
CTXS15K
£146.00
FTXS20K
£154.00
FTXS25K
£165.00
Wall Mounted Low Inverter Fan Coil Units
Trade Fan Coil Unit Price
FTX20KV
£108.00
FTX25KV
£119.00
FTX35KV
£135.00
Flexi Fan Coil Units
Trade Fan Coil Unit Price
FLXS25B
£376.00
FLXS35B9
£423.00
FLXS50B
£459.00
Nexura Floor Standing Fan Coil Units
Trade Fan Coil Unit Price
FVXG25K
£631.00
FVXG35K
£679.00
FVXG50K
£744.00
Floor Standing Cased Fan Coil Units
Trade Fan Coil Unit Price
FVXS25F
£523.00
FVXS35F
£564.00
FVXS50F
£616.00
Compact Roundflow Cassette Fan Coil Units
Trade Fan Coil Unit Price
FCQG35F
£ 683.00
FCQG50F
£699.00
FCQG60F
£743.00
600 x 600 Fully Flat Cassette Fan Coil Units
Trade Fan Coil Unit Price
FFQ25C
£636.00
FFQ35C
£696.00
FFQ50C
£766.00
Ceiling Suspended Fan Coil Units
Trade Fan Coil Unit Price
FHQ35CB
£666.00
FHQ50CB
£722.00
FHQ60CB
£792.00
Concealed Ceiling Fan Coil Units
Trade Fan Coil Unit Price
FDBQ25B
£424.00
FBQ35D
£515.00
FBQ50D
£541.00
FBQ60D
£600.00
Slim Concealed Ceiling Fan Coil Units
Trade Fan Coil Unit Price
FDXS25F
£394.00
FDXS35F
£441.00
FDXS50F9
£477.00
FDXS60F
£524.00
Concealed Floor Standing Unit
Trade Fan Coil Unit Price
FNQ25A
£407.00
FNQ35A
£503.00
FNQ50A
£586.00
FNQ60A
£646.00
40
Residential, Commercial and Industrial
FTXS35K
£189.00
FTXS42K
£212.00
FTXS50K
£294.00
FTXS60G
£300.00
FTXS71G
£400.00
Notes:
FFQ60C
£809.00
i)Accessories for fan coils - refer to pair
system pages
ii)All fan coil units standard with auto restart
after power failure
iii)All fan coil units supplied as standard with
remote controller
iv)FDXS fan coil units supplied as standard
with air filter
v)2MXS40-50H can only be used with
FTXG, FTXS, FTX, FDXS, FVXG, FVXS, FLXS,
FNQ fan coil units
vi)One wifi adaptor per fan coil for
online control
SPLIT, SKY AIR HEAT PUMPS
MXS-E/F/G/H/K
Multi Series Inverters
Outdoor Units
Capacity
Dimensions
Weight
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Number of Connected Indoor Units
Air Flow Rate (Cooling) Nom
Trade Condensing Unit Price
kW
kW
mm
mm
mm
kg
Phase
Hz
V
amps
amps
amps
kg
dBA
m
m
inches (mm)
inches (mm)
m3/sec
2MXS40H
2MXS50H
3MXS40K
3MXS52E
3MXS68G
4MXS68F
4MXS80E
5MXS90E
4.00
4.40
550
765
285
38
5.00
5.70
550
765
285
42
4.00
4.60
735
936
300
49
5.20
6.80
735
936
300
49
6.80
8.60
735
936
300
58
6.80
8.60
735
936
300
58
8.00
9.60
770
900
320
72
9.00
10.40
770
900
320
73
4
20
4
20
4
20
2.6
48
61
60
15
4x 1/4 (6.4)
2x 3/8 (9.5)
2x 1/2 (12.7)
3.0
52
66
75
15
5x 1/4 (6.4)
2x3/8 (9.5)
1/2 (12.7)
2x 5/8 (15.9)
5
0.908
£2,141.00
1ph
50
230
Refer to Multi Combination Tables
4
4
20
20
R410A
2.0
2.6
46
48
59
61
50
60
15
15
3x 1/4 (6.4)
3x 1/4 (6.4)
2x 3/8 (9.5)
3/8 (9.5)
1/2 (12.7)
2x 1/2 (12.7)
4
16
4
16
4
16
1.2
47
62
30
15
2x 1/4 (6.4)
2x 3/8 (9.5)
1.6
48
63
30
15
2x 1/4 (6.4)
3/8 (9.5)
1/2 (12.7)
2.0
46
59
50
15
3x 1/4 (6.4)
2x 3/8 (9.5)
1/2 (12.7)
2
0.55
2
0.567
3
0.75
3
0.75
3
0.823
4
0.823
3.0
48
62
70
15
4x 1/4 (6.4)
3/8 (9.5)
1/2 (12.7)
2x 5/8 (15.9)
4
0.908
£998.00
£1,104.00
£1,040.00
£1,156.00
£1,637.00
£1,766.00
£1,989.00
Accessories:
Notes:
Accessory Ref
Description
Trade Price
K.CWB90-2
K.DT1
K.DT2
K.CGM
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensate drip tray for use with Split ODU - tray width 800mm
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
£37.00
£54.00
£59.00
£296.00
i) Minimum ambient operating temperatures:
2MXS40, 50
3MXS40, 52, 68
4MXS68, 80
5MXS90
Cooling
Heating
10°C
-10°C
-10°C
-10°C
-15°C
-15°C
-15°C
-15°C
Painted Units
Customers sometimes require visible units to be less
obtrusive, whether for aesthetic or planning reasons.
Daikin UK offer a customised service where we can repaint our
units to any specified RAL or BS finish. Our repainting service is
done in house in our purpose built facility and includes removing
base paint to give a uniform, long lasting and professional finish.
We have repainted fan coils, decoration panels, BS boxes and all
types of condensers for a number of clients.
PRICE ON APPLICATION
Lead time: 2-3 weeks
Applicable units: All
When asking for a quotation or ordering, please state the unit you
require along with the finish requirements e.g. colour, pattern etc.
Please note:
The stated lead times are a guide, this can be influenced by the design and
complexity of the requirement.
Price List 2016
41
VRV IV Condensing Unit – Low Height Compact Mini VRV
Outdoor Units
Capacity
Power Input 50Hz
Nominal Cooling
Nominal Heating
Cooling
Heating
EER
COP
Dimensions
Height x Width x Depth
Weight
Refrigerant Circuit
Refrigerant Type
Sound Pressure (Nom)
Cooling
Sound Power (Nom)
Cooling
Maximum No of Connectable Units
Electrical Details
Power Supply
Running Current
Starting Current
Fuse Rating
Piping Limits
Total Piping length
Maximum Length
Maximum Vertical Rise
Piping Connections
Liquid
Gas
Capacity Index Limit
RXYSCQ4TV1
RXYSCQ5TV1
12.1
12.1
3.43
3.18
3.53
3.81
14
14
4.26
3.91
3.29
3.58
kW
kW
kW
kW
mm
kg
823 x 940 x 460
94
94
R410A
dBA
dBA
51
68
8
Phase / Hz / V
amps
amps
amps
m
m
m
inch (mm)
inch (mm)
Trade Condensing Unit Price
52
69
10
1 / 50 / 230
19.0
4
32
300
70 (90 equivalent)
30
3/8 (9.5)
5/8 (15.9)
50~130
3/8 (9.5)
5/8 (15.9)
62.5~162.5
£2,462.00
£2,767.00
823mm high
>New low height Mini VRV, making complying with planning
restrictions in towns and cities easier
> Compact – Only 823mm high
> Lightweight – for simple installation
> Variable Refrigerant temperature – Enhanced efficiency
> In addition to VRV fan coils, low height Mini VRV is connectable to:
Stylish indoor units – Emura and Nexura – as well as Air Handling
Units and Biddle Air curtains
> Single phase
Less than 1m
Features:
Parapet wall
SPLIT, SKY AIR HEAT PUMPS
VRV IV S-Series RXYSCQ-T
Roof
BPMK
Mini VRV for Residential Applications
> M
ulti Series Inverters can connect up to five indoor units from across the split range
> Up to nine indoor units can be connected to a single Mini-VRV outdoor unit. To allow connection of the split indoor units,
the system will need two or three port BPMK boxes
> BPMK boxes open up the full range of split indoor unit style – from the stylish Emura to the radiant heat of the Nexura
> For full details of the expanded range of capacities in the Mini-VRV range, including the new low height S series, refer to page 70
Daikin’s range of split indoor units
Dimensions
Weight
Total Indoor Capacity
Connectable Units
Electrical Details
HxWxD
Piping Limits
Piping Connections Indoor
Piping Connections Outdoor
BPMKS967A2
mm
kg
kW
Power Supply
Power Input
kW
Maximum Total - outdoor to BPMK box
Distance from BPMK to indoor
Liquid
Inches (mm)
Gas
Inches (mm)
Liquid
Inches (mm)
Gas
Inches (mm)
Trade List Price
BPMKS967A3
180 x 650 x 350
7.5
14.2
2
8
20.8
3
1~ 220 - 240V, 50 Hz
0.01
55
15
2 x 1/4 (6.4)
2 x 5/8 (15.9)
1 x 3/8 (9.5)
1 / 3/4 (19.0)
0.01
55
15
3 x 1/4 (6.4)
3 x 5/8 (15.9)
1 x 3/8 (9.5)
1 / 3/4 (19.0)
£356.00
£380.00
Accessories:
Notes:
Accessory Ref
Description
Trade Price
KHRQ22M20T
R410A 2 Pipe refnet joint
£29.00
42
Residential, Commercial and Industrial
i)Mini-VRV units are subject to VRV
discount level. Split indoor units
bought to connect to mini VRV
are still subject to Split discount
levels. BPMK Boxes are bought at
accessories discount levels.
SPLIT, SKY AIR HEAT PUMPS
RZQ-C
Super Inverter
Outdoor Units
Dimensions
Super Inverter
Height
Width
Depth
Weight
Electrical Details
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
High / Nom*
RZQ200C
1680
930
765
183
mm
mm
mm
kg
RZQ250C
1680
930
765
184
3ph
data book
A
A
A
4
25
4
25
3+E / 1.5
inches (mm)
m
m
m
g/m
kg
dBA
3/8 (9.5) / 7/8 (22.2)
100
30
30
1/2 (12.7) / 7/8 (22.2)
100
30
30
Refer to Installation Manual
m3/sec
Trade Condensing Unit Price
8.3
57 / 78
2.85*
9.3
57 / 78
2.85*
£2,576.00
£2,698.00
Possible Combinations
Twin, Triple and Double Twin Outdoor Units
Outdoor
20kW Twin
RZQ200C Three Phase
20kW Triple
RZQ200C Three Phase
20kW Triple
RZQ200C Three Phase
20kW Double Twin
RZQ200C Three Phase
25kW Twin
RZQ250C Three Phase
25kW Double Twin
RZQ250C Three Phase
Indoor Type
Material
Remote
Refnet
System Price
Cassette
Hi-COP Cassette
Under Ceiling Cassette
Wall Mount
Ceiling Suspended
Ducted
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
Hi-COP Cassette
Under Ceiling Cassette
Wall Mount
Ceiling Suspended
Ducted
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
Hi-COP Cassette
Under Ceiling Cassette
Ceiling Suspended
Ducted
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
2 x FCQG100F
2 x FCQHG100F
2 x FUQ100F
2 x FAQ100CB
2 x FHQ100C
2 x FBQ100D
3 x FCQG60F
3 x FFQ60F
3 x FHQ60C
3 x FBQ60D
3 x FDXS60F
3 x FNQ60A
3 x FCQG71F
3 x FCQHG71F
3 x FUQ71F
3 x FAQ71CB
3 x FHQ71C
3 x FBQ71D
4 x FCQG50F
4 x FFQ50F
4 x FHQ50C
4 x FBQ50D
4 x FDXS50F
4 x FNQ50A
2 x FCQG125F
2 x FCQHG125F
2 x FUQ125F
2 x FHQ125C
2 x FBQ125D
4 x FCQG60F
4 x FFQ60F
4 x FHQ60C
4 x FBQ60D
4 x FDXS60F
4 x FNQ60A
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
1 x KHRQ250H7
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
£4,057.00
£4,057.00
£4,157.00
£3,893.00
£4,243.00
£4,075.00
£4,482.00
£4,680.00
£4,629.00
£4,053.00
£3,825.00
£4,191.00
£4,614.00
£4,614.00
£4,824.00
£4,500.00
£5,031.00
£4,833.00
£4,979.00
£5,247.00
£5,071.00
£4,347.00
£4,091.00
£4,527.00
£4,406.00
£4,406.00
£4,536.00
£4,920.00
£4,588.00
£5,340.00
£5,604.00
£5,536.00
£4,768.00
£4,464.00
£4,952.00
Price List 2016
43
SPLIT, SKY AIR HEAT PUMPS
RZQG-L
Seasonal Smart
Outdoor Units
Dimensions
Height
Width
Depth
Weight
Electrical Details
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power
Air Flow Rate (Cooling)
High / Nom*
Seasonal Smart
Seasonal Smart
Single Phase
3 Phase
RZQG71L9V1 RZQG100L9V1 RZQG125L9V1 RZQG140L9V1 RZQG71L8Y1 RZQG100L8Y1 RZQG125L8Y1 RZQG140LY1
mm
990
1430
1430
1430
990
1430
1430
1430
mm
940
940
940
940
940
940
940
940
mm
320
320
320
320
320
320
320
320
kg
78
102
102
102
80
101
101
101
1ph
3ph
A
data book
data book
A
4
4
4
4
4
4
4
4
A
20
32
32
32
16
20
20
20
3+E / 1.5
inches (mm)
3/8 (9.5) / 5/8 (15.9)
m
50
75
75
75
50
75
75
75
m
30
m
30
g/m
Refer to Installation Manual
kg
2.9
4.0
4.0
4.0
2.9
4.0
4.0
4.0
dBA
48 / 43
50 / 45
51 / 45
52 / 45
48 / 43
50 / 45
51 / 45
52 / 45
64
66
67
69
64
66
67
69
m3/sec
0.98
1.17
1.17
1.40
0.98
1.17
1.17
1.40
Trade Condensing Unit Price
£1,191.00
£1,514.00
£1,666.00
£1,901.00
£1,227.00
£1,584.00
£1,743.00
£2,002.00
Possible Combinations
Twin, Triple and Double Twin Outdoor Units
Outdoor
RZQG71L9V1 Single Phase
7.1kW Twin
RZQG71L8Y1 Three Phase
RZQG100L9V1 Single Phase
10kW Twin
RZQG100L8Y1 Three Phase
RZQG100L9V1 Single Phase
10kW Triple
RZQG100L8Y1 Three Phase
RZQG125L9V1 Single Phase
12kW Twin
RZQG125L8Y1 Three Phase
44
Residential, Commercial and Industrial
Indoor Type
Material
Remote
Refnet
System Price
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
2 x FCQG35F
2 x FFQ35F
2 x FHQ35C
2 x FBQ35D
2 x FDXS35F
2 x FNQ35A
2 x FCQG35F
2 x FFQ35F
2 x FHQ35C
2 x FBQ35D
2 x FDXS35F
2 x FNQ35A
2 x FCQG50F
2 x FFQ50F
2 x FHQ50C
2 x FBQ50D
2 x FDXS50F9
2 x FNQ50A
2 x FCQG50F
2 x FFQ50F
2 x FHQ50C
2 x FBQ50D
2 x FDXS50F9
2 x FNQ50A
3 x FCQG35F
3 x FFQ35F
3 x FHQ35C
3 x FBQ35D
3 x FDXS35F
3 x FNQ35A
3 x FCQG35F
3 x FFQ35F
3 x FHQ35C
3 x FBQ35D
3 x FDXS35F
3 x FNQ35A
2 x FCQG60F
2 x FFQ60F
2 x FHQ60C
2 x FBQ60D
2 x FDXS60F
2 x FNQ60A
2 x FCQG60F
2 x FFQ60F
2 x FHQ60C
2 x FBQ60D
2 x FDXS60F
2 x FNQ60A
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
£2,510.00
£2,536.00
£2,476.00
£2,174.00
£2,026.00
£2,150.00
£2,546.00
£2,572.00
£2,512.00
£2,210.00
£2,062.00
£2,186.00
£2,865.00
£2,999.00
£2,911.00
£2,549.00
£2,421.00
£2,639.00
£2,935.00
£3,069.00
£2,981.00
£2,619.00
£2,491.00
£2,709.00
£3,476.00
£3,515.00
£3,425.00
£2,972.00
£2,750.00
£2,936.00
£3,546.00
£3,585.00
£3,495.00
£3,042.00
£2,820.00
£3,006.00
£3,105.00
£3,237.00
£3,203.00
£2,819.00
£2,667.00
£2,911.00
£3,182.00
£3,314.00
£3,280.00
£2,896.00
£2,744.00
£2,988.00
RZQG125L9V1 Single Phase
12kW Triple
RZQG125L8Y1 Three Phase
RZQG125L9V1 Single Phase
12kW Double Twin
RZQG125L8Y1 Three Phase
RZQG140L9V1 Single Phase
14kW Twin
RZQG140LY1
Three Phase
RZQG140L9V1 Single Phase
14kW Triple
RZQG140LY1
Three Phase
RZQG140L9V1 Single Phase
14kW Double Twin
RZQG140LY1
Three Phase
Indoor Type
Material
Remote
Refnet
System Price
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
Hi-COP Cassette
Under Ceiling Cassette
Wall Mount
Ceiling Suspended
Ducted
Cassette
Hi-COP Cassette
Under Ceiling Cassette
Wall Mount
Ceiling Suspended
Ducted
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
2 x FCQG71F
2 x FCQHG71F
2 x FUQ71F
2 x FAQ71CB
2 x FHQ71C
2 x FBQ71D
2 x FCQG71F
2 x FCQHG71F
2 x FUQ71F
2 x FAQ71CB
2 x FHQ71C
2 x FBQ71D
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
£3,676.00
£3,877.00
£3,745.00
£3,202.00
£3,010.00
£3,337.00
£3,753.00
£3,954.00
£3,822.00
£3,279.00
£3,087.00
£3,414.00
£4,257.00
£4,309.00
£4,189.00
£3,585.00
£3,289.00
£3,537.00
£4,334.00
£4,386.00
£4,266.00
£3,662.00
£3,366.00
£3,614.00
£3,428.00
£3,428.00
£3,568.00
£3,352.00
£3,706.00
£3,574.00
£3,529.00
£3,529.00
£3,669.00
£3,453.00
£3,807.00
£3,675.00
£3,911.00
£4,112.00
£3,980.00
£3,437.00
£3,245.00
£3,572.00
£4,012.00
£4,213.00
£4,081.00
£3,538.00
£3,346.00
£3,673.00
£4,492.00
£4,544.00
£4,424.00
£3,820.00
£3,524.00
£3,772.00
£4,593.00
£4,645.00
£4,525.00
£3,921.00
£3,625.00
£3,873.00
SPLIT, SKY AIR HEAT PUMPS
Outdoor
Accessories:
Accessory Ref
Description
Trade Price
KHRQ22M20T
KHRQ127H
KHRQ250H7
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
R410A 2 Pipe Refnet Joint
Triple Refnet Joint - RZQS71~140,RZQ100~140
Triple Refnet Joint - RZQ200~250
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£29.00
£65.00
£81.00
£37.00
£46.00
£59.00
£296.00
£354.00
Notes:
i)Accessories for fan coils and condensing
units - refer to pair system pages
Maximum Fuse size for Twin, Triple and Double Twin Outdoor Units
Outdoor Units
Power
71
100
125
140
200
RZQG & RZQSG
Single Phase
20 amp
32 amp
32 amp
32 amp
-
-
Three Phase
16 amp
20 amp
20 amp
20 amp
-
-
Three Phase
-
-
-
-
20amp
20amp
RZQ-C
250
Note:
Max fuse size based on current price list series indoor units. Refer to data-book for more details.
Price List 2016
45
SPLIT, SKY AIR HEAT PUMPS
RZQSG-L
Seasonal Classic
Outdoor Units
Dimensions
Height
Width
Depth
Weight
Electrical Details
Power Supply
Running Current
Starting Current
Max Fuse Size
Interconnection Wiring Core / Cable size
Piping Connections
Liquid / Gas
Pipework
Maximum Length
Maximum Vertical Rise
Precharged to
Additional Charge
Holding Charge
Sound Pressure (Cooling) Nom / Night Quiet
Sound Power Air Flow Rate (Cooling)
High
mm
mm
mm
kg
A
A
A
inches (mm)
m
m
m
g/m
kg
dBA
m3/sec
Trade Condensing Unit Price
RZQSG71L3V1
770
900
320
67
4
20
50
2.75
49 / 49
65
0.87
£820.00
Seasonal Classic
Seasonal Classic
Single Phase
3 Phase
RZQSG100L9V1 RZQSG125L9V1 RZQSG140L9V1 RZQSG100L8Y1 RZQSG125L8Y1
990
990
1430
990
990
940
940
940
940
940
320
320
320
320
320
81
81
102
82
82
1ph
3ph
data book
data book
4
4
4
4
4
32
32
32
20
20
3+E / 1.5
3/8 (9.5) / 5/8 (15.9)
50
50
50
50
50
30
30
Refer to Installation Manual
2.9
2.9
4.0
2.9
2.9
53 / 49
54 / 49
53 / 49
53 / 49
54 / 49
69
70
69
69
70
1.27
1.28
1.38
1.27
1.28
£1,135.00
£1,245.00
£1,386.00
£ 1,170.00
£1,282.00
RZQSG140LY1
1430
940
320
101
4
20
50
4.0
53 / 49
69
1.38
£1,428.00
Possible Combinations
Twin, Triple and Double Twin Outdoor Units
Outdoor
7.1kW Twin
RZQSG71L3V1 Single Phase
RZQSG100L9V1 Single Phase
10kW Twin
RZQSG100L8Y1 Three Phase
RZQSG100L9V1 Single Phase
10kW Triple
RZQSG100L8Y1 Three Phase
RZQSG125L9V1 Single Phase
12kW Twin
RZQSG125L8Y1 Three Phase
46
Residential, Commercial and Industrial
Indoor Type
Material
Remote
Refnet
System Price
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
2 x FCQG35F
2 x FFQ35F
2 x FHQ35C
2 x FBQ35D
2 x FDXS35F
2 x FNQ35A
2 x FCQG50F
2 x FFQ50F
2 x FHQ50C
2 x FBQ50D
2 x FDXS50F9
2 x FNQ50A
2 x FCQG50F
2 x FFQ50F
2 x FHQ50C
2 x FBQ50D
2 x FDXS50F9
2 x FNQ50A
3 x FCQG35F
3 x FFQ35F
3 x FHQ35C
3 x FBQ35D
3 x FDXS35F
3 x FNQ35A
3 x FCQG35F
3 x FFQ35F
3 x FHQ35C
3 x FBQ35D
3 x FDXS35F
3 x FNQ35A
2 x FCQG60F
2 x FFQ60F
2 x FHQ60C
2 x FBQ60D
2 x FDXS60F
2 x FNQ60A
2 x FCQG60F
2 x FFQ60F
2 x FHQ60C
2 x FBQ60D
2 x FDXS60F
2 x FNQ60A
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
£2,510.00
£2,536.00
£2,476.00
£2,174.00
£2,026.00
£2,150.00
£2,865.00
£2,999.00
£2,911.00
£2,549.00
£2,421.00
£2,639.00
£2,935.00
£3,069.00
£2,981.00
£2,619.00
£2,491.00
£2,709.00
£3,476.00
£3,515.00
£3,425.00
£2,972.00
£2,750.00
£2,936.00
£3,546.00
£3,585.00
£3,495.00
£3,042.00
£2,820.00
£3,006.00
£3,105.00
£3,237.00
£3,203.00
£2,819.00
£2,667.00
£2,911.00
£3,182.00
£3,314.00
£3,280.00
£2,896.00
£2,744.00
£2,988.00
RZQSG125L9V1 Single Phase
12kW Triple
RZQSG125L8Y1 Three Phase
RZQSG125L9V1 Single Phase
12kW Double Twin
RZQSG125L8Y1 Three Phase
RZQSG140L9V1 Single Phase
14kW Twin
RZQSG140LY1
Three Phase
RZQSG140L9V1 Single Phase
14kW Triple
RZQSG140LY1
Three Phase
RZQSG140L9V1 Single Phase
14kW Double Twin
RZQSG140LY1
Three Phase
Indoor Type
Material
Remote
Refnet
System Price
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
Hi-COP Cassette
Under Ceiling Cassette
Wall Mount
Ceiling Suspended
Ducted
Cassette
Hi-COP Cassette
Under Ceiling Cassette
Wall Mount
Ceiling Suspended
Ducted
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
Cassette
600 x 600 Fully Flat Cassette
Ceiling Suspended
Ducted
Slim Duct
Concealed Floor Standing
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
2 x FCQG71F
2 x FCQHG71F
2 x FUQ71F
2 x FAQ71CB
2 x FHQ71C
2 x FBQ71D
2 x FCQG71F
2 x FCQHG71F
2 x FUQ71F
2 x FAQ71CB
2 x FHQ71C
2 x FBQ71D
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
3 x FCQG50F
3 x FFQ50F
3 x FHQ50C
3 x FBQ50D
3 x FDXS50F
3 x FNQ50A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
4 x FCQG35F
4 x FFQ35F
4 x FHQ35C
4 x FBQ35D
4 x FDXS35F
4 x FNQ35A
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x BRC1E52
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ22M20T
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
1 x KHRQ127H
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
3 x KHRQ22M20T
£3,676.00
£3,877.00
£3,745.00
£3,202.00
£3,010.00
£3,337.00
£3,753.00
£3,954.00
£3,822.00
£3,279.00
£3,087.00
£3,414.00
£4,257.00
£4,309.00
£4,189.00
£3,585.00
£3,289.00
£3,537.00
£4,334.00
£4,386.00
£4,266.00
£3,662.00
£3,366.00
£3,614.00
£3,428.00
£3,428.00
£3,568.00
£3,352.00
£3,706.00
£3,574.00
£3,529.00
£3,529.00
£3,669.00
£3,453.00
£3,807.00
£3,675.00
£3,911.00
£4,112.00
£3,980.00
£3,437.00
£3,245.00
£3,572.00
£4,012.00
£4,213.00
£4,081.00
£3,538.00
£3,346.00
£3,673.00
£4,492.00
£4,544.00
£4,424.00
£3,820.00
£3,524.00
£3,772.00
£4,593.00
£4,645.00
£4,525.00
£3,921.00
£3,625.00
£3,873.00
SPLIT, SKY AIR HEAT PUMPS
Outdoor
Accessories:
Accessory Ref
Description
Trade Price
KHRQ22M20T
KHRQ127H
KHRQ250H7
K.CWB90-2
K.CWB140-2
K.DT2
K.CGM
K.CGL
R410A 2 Pipe Refnet Joint
Triple Refnet Joint - RZQS71~140, RZQ100~140
Triple Refnet Joint - RZQ200~250
Condensing unit bracket - up to size 71, max weight 90kg of ODU
Condensing unit bracket - sizes 100 to 140, max weight 140kg of ODU
Condensate drip tray for use with Sky Air ODU - tray width 1100mm
Condensing Unit Guard size 42-71
Condensing Unit Guard size 100-140 including RXYSQ
£29.00
£65.00
£81.00
£37.00
£46.00
£59.00
£296.00
£354.00
Notes:
i)Accessories for fan coils and condensing
units - refer to pair system pages
Maximum Fuse size for Twin, Triple and Double Twin Outdoor Units
Outdoor Units
Power
71
100
125
140
200
RZQG & RZQSG
Single Phase
20 amp
32 amp
32 amp
32 amp
-
-
Three Phase
16 amp
20 amp
20 amp
20 amp
-
-
Three Phase
-
-
-
-
20amp
20amp
RZQ-C
250
Note:
Max fuse size based on current price list series indoor units. Refer to data-book for more details.
Price List 2016
47
Server rooms & IT applications have some key differences to comfort cooling applications.
Daikin has developed specific infrastructure cooling equipment to ensure efficient, reliable 24 hour
cooling – now with ErP compliant Energy Labels.
Comfort cooling
Infrastructure cooling
> 60-70% temperature control
> 30-40% humidity control
> 80-90% temperature control
> 10-20% humidity control
- Humidity is present
- Balanced sensible and latent capacity
- No or limited humidity
- Pure sensible capacity
How do comfort systems perform in infrastructure cooling applications?
traditional solution
dedicated solution
Symmetric indoor-outdoor system combination
Boosted capacity indoor system combination
12Te
10
kW RH%
12
Te
55
12
50
10
kW RH%
12
10
55
35
6
6
30
4
4
25
Time
Relative Humidity:
40
35
6
30
4
25
Time
improved solution
reduces over time
Boosted capacity indoors increase the heat transfer capacity at
Capacity:reduced
Evaporating temp:
8
Capacity
4
8
40
Capacity
6
8
sensible capacity
increase
45
Evaporating Temperature
8
Between
20-40%
50
10
45
Evaporating Temperature
SPLIT, SKY AIR HEAT PUMPS
Infrastructure Cooling
drops to compensate reduced capacity
low relative humidity
too low Te can lead to freeze-up
Allows the system to operate with higher Te, guaranteeing
prevention, causing system downtime
continuous operation and reducing unwanted dehumidification
Infrastructure cooling systems, with larger capacity indoor units can deliver higher sensible capacities
Nominal Capacity
Comfort Cooling Pairing
Indoor
Outdoor
22°C set point / 11C WB (35% RH) <25°C ambient
Total Capacity / Sensible Capacity
Sensible Ratio
22°C Set point / 16 WB (54% RH) 30°C ambient
Total Capacity / Sensible Capacity
Sensible Ratio
Comfort
Cooling
Infrastructure
Cooling
Comfort
Cooling
Infrastructure
Cooling
Comfort
Cooling
Infrastructure
Cooling
6.8kW
71 / 71
FAQ71C9
RZQG71L9V1
6.8kW
71 / 100
FAQ100C9
RZQG71L9V1
9.5kW
100 / 100
FHQ100CB
RZQG100L9V1
9.5kW
100 / 140
FHQ140CB
RZQG100L9V1
13.5kW
125 / 125
FHQ125CB
RZQG125L9V1
12.0kW
125 / 140
FHQ140CB
RZQG125L9V1
n/a
6.02 / 6.02
n/a
7.48 / 7.48
n/a
9.34 / 9.34
n/a
100%
n/a
100%
n/a
100%
7.76 / 5.32
7.8 / 5.71
10.8 / 7.44
9.70 / 7.54
13.6 / 9.3
12.12 / 9.00
69%
73%
69%
78%
68%
74%
Daikin’s infrastructure cooling solution can deliver pure sensible capacity in low relative humidity applications.
The solution uses indoor units of larger capacity than outdoor units, all with ErP Energy Labels.
To make selection simple, tables are available showing total & sensible capacity at:
> Ambient range in cooling from -15°C to +40°C
> Dry build temperature range from 16°C to 27°C
> Wet bulb temperature range from 11°C to 16°C
For selection advice & capacity tables, please talk to your local Daikin office.
48
Residential, Commercial and Industrial
FOR 2016
SPLIT, SKY AIR HEAT PUMPS
NEW
Sky Air – Duty Rotation
In a infrastructure cooling application, it is normal to have a standby air conditioning unit(s).
The standby unit will automatically operate in the event of a fault with one of the duty units.
It is also normal to rotate the operation of the duty and standby units to ensure equal use of all units.
Single remote controller
required for up to 16 groups
NEW BRC1E53A Remote Controller
Daikins’ latest generation of hard wired remote controller now
supports automatic duty rotation and standby operation on fault.
> One controller for up to 16 systems
> Programmable duty rotation changeover period
> Automatic operation of standby unit on fault
Model
Description
Related Fan Coil
Trade Price
BRC1E53A
Premium wired remote controller with duty rotation function
FBQ-D, FAQ-C9, FHQ-CB
£80.00
RTD-10 Interface
A single interface per group to carry out automatic duty rotation
and standby operation on fault or high temperature.
> Programmable duty rotation changeover period
> Automatic operation of standby unit on fault and fixed high temperature
> Dual level alarm volt free contact output
1 off RTD-10 and
1 off BRC1E52A
required
per group.
Control of up
to 8 groups
possible
Model
Description
Related Fan Coil
Trade Price
RTD-10
Control interface with duty rotation function
All units with P1/P2 interface*
£210.00
Automatic Changeover
A single control panel to carry out automatic duty rotation
and standby operation on fault or high temperature.
>
>
>
>
>
>
24hr duty rotation changeover period
Automatic operation of standby unit on fault and adjustable high temperature
Visual indication of unit status
Fire alarm & condense pump interlocks
Volt free contact alarm output
Built-in remote controllers and interface PCBs
Model
Description
Related Fan Coil
Trade Price
UK.PANEL 2SKYAIR
UK.PANEL 3SKYAIR
UK.PANEL 4SKYAIR
Changeover panel for 2 SkyAir systems
Changeover panel for 3 SkyAir systems
Changeover panel for 4 SkyAir systems
All units with P1/P2 interface*
All units with P1/P2 interface*
All units with P1/P2 interface*
£1,731.00
£2,003.00
£3,225.00
* All SkyAir units, all VRV units and some Split units. For Split units check exact unit specification for compatibility
Price List 2016
49
Air curtains are the ideal solution to combat the issue of
climate separation across retail outlets or office doorways.
In conjunction with Biddle, Daikin ERQ heat pump air curtain
solution combines the benefits of the Biddle air curtain technology
with the benefits of Daikin ERQ heat pump inverter technology.
Features and benefits:
> Energy savings up to 72% compared with
electric air curtains
> Short payback times – less than 1.5 years
> Wide capacity range for maximum application
potential plus flexible control options
> R-410A refrigerant, single and 3 phase
> Wide operation range: -20~15.5°C in heating
> Air curtain rectifier technology –
deep penetrating airstream
> Constant air velocity technology –
all year round efficiency
> European patent
> 1.0, 1.5, 2.0 and 2.5 metre door widths
> Door heights of up to 3.7 metres
> Choice of colour RAL9010:White or RAL9006:Grey
Using a combination of rectifier technology, air velocity and temperature
control, Daikin ERQ heat pump air curtains deliver greater comfort to staff
and customers alike, all year round, in all weathers.
BIDDLE AIR CURTAINS & ERQ PAIRS ARE LISTED ON ECA –
For product listing refer to: https://etl.decc.gov.uk/etl/site/etl.html
F = Free hanging model
C = Cassette model
R = Recessed model
Biddle Comfort air curtain range
Selection
3.7m
4m
Maximum door height (m)
SPLIT, SKY AIR HEAT PUMPS
CYQS/M/L - DK - F/C/R
3.2m
2.8m
2.7m
3m
1) U
se the Door Height graph to
determine the Air Curtain size
relevant to your application
3.1m
2.35m
2.3m
2.0m
2.5m
2m
2) W
hen you know the size (S/M/L),
refer to specific tables to select the
model for your required door width
1m
S
M
L
S
M
L
S
M
L
3) S elect outdoor unit to pair door
curtain, based on efficiency and
power source
Installation condition
Ideal for doors in a shopping
centre or revolving door entrance
S
For more exposed doors with
some direct wind, suitable for
ground floor applications
For areas exposed to higher wind
speeds i.e. open stairwell or balcony
door at higher than ground level
Biddle Standard Air Curtain (Small) – Door height 2m to 2.7m
Maximum Door Width
Mounting Height *2 Max / Min
Model Name
Type
Heating Capacity
Delta T
Inlet = room temperature
Power Input (50Hz) Fan only / Heating
Dimensions
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections Liquid (OD) / Gas
Power Supply
m
m
*=F
speed 3 kW
speed 3 °K
kW
mm
mm
mm
kg
mm
speed 3 m3/sec
speed 3 dBA
inch (mm)
Phase / Hz / V
Trade Unit Price
270
1,500
590
66
1.50
2.7 / 2.0
CYQS150DK80*BN
*=C
9.00
15
0.35 / 0.35
270
1,500
821
83
white RAL9010
420
0.485
49
R-410A
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
£2,908.00
£2,908.00
2.00
2.7 / 2.0
CYQS200DK100*BN
*=C
11.60
15
0.46 / 0.46
270
2,000
821
102
white RAL9010
420
0.647
50
R-410A
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
*=R
*=F
270
1,548
561
88
270
2,000
590
83
£3,065.00
£3,538.00
£3,538.00
2.50
2.7 / 2.0
CYQS250DK140*BN
*=C
16.20
16
0.58 / 0.58
270
2,500
821
129
white RAL9010
420
0.808
51
R-410A
3/8 (9.5) / 3/4 (19)
1 / 50 / 230
*=R
*=F
270
2,048
561
108
270
2,500
590
107
£3,836.00
£3,972.00
£3,972.00
50
Residential, Commercial and Industrial
ERQ100AV1
ERQ100 AV1
ERQ125AV1 / AW1
270
2,548
561
137
£4,299.00
* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed
Condensing Unit Selection for Small Door Curtain
Standard Efficiency
Improved Efficiency
High Efficiency
*=R
ERQ125AV1 / AW1
ERQ140AV1
ERQ200AV1
SPLIT, SKY AIR HEAT PUMPS
M Biddle Standard Air Curtain (Medium) – Door height 2.3m to 3.2m
Maximum Door Width
m
1.00
1.50
2.00
2.5
Mounting Height *2 Max / Min
m
3.2 / 2.3
3.2 / 2.3
3.2 / 2.3
3.2 / 2.3
Model Name
CYQM100DK80*BN
Type
*=F
Heating Capacity
Delta T
Inlet = room temperature
Power Input (50Hz) Fan only / Heating
Dimensions
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections Liquid (OD) / Gas
Power Supply
speed 3 kW
speed 3 °K
kW
mm
mm
mm
kg
mm
speed 3 m3/sec
speed 3 dBA
inch (mm)
Phase / Hz / V
Trade Unit Price
*=C
CYQM150DK80*BN
*=R
9.20
17
0.37 / 0.37
270
270
270
1,000
1,000
1,048
590
821
561
57
68
66
white RAL9010
420
0.446
50
R-410A
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
*=F
*=C
*=R
11.00
14
0.56 / 0.56
270
270
270
1,500
1,500
1,548
590
821
561
73
88
93
white RAL9010
420
0.669
51
R-410A
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
CYQM200DK100*BN
*=F
*=C
CYQM250DK140*BN
*=R
13.40
13
0.75 / 0.75
270
270
270
2,000
2,000
2,048
590
821
561
94
111
117
white RAL9010
420
0.892
53
R-410A
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
*=F
*=C
*=R
19.90
15
0.94 / 0.94
270
270
270
2,500
2,500
2,548
590
821
561
108
136
144
white RAL9010
420
1.115
54
R-410A
3/8 (9.5) / 3/4 (19)
1 / 50 / 230
£2,820.00 £2,820.00 £2,910.00 £3,360.00 £3,360.00 £3,515.00 £4,207.00 £4,207.00 £4,504.00 £4,816.00 £4,816.00 £5,137.00
* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed
Condensing Unit Selection form Medium Door Curtain
Standard Efficiency
Improved Efficiency
High Efficiency
L
ERQ100AV1
ERQ100AV1
ERQ125AV1 / AW1
ERQ100AV1
ERQ125AV1 / AW1
ERQ140AV1
ERQ200AW1
ERQ250AW1
Biddle Standard Air Curtain (Large) – Door height 2.5m to 3.7m
Maximum Door Width
m
1.00
1.50
2.00
2.5
Mounting Height *2 Max / Min
m
3.7 / 2.5
3.7 / 2.5
3.7 / 2.5
3.7 / 2.5
Model Name
CYQL100DK125*BN
Type
*=F
Heating Capacity
Delta T
Inlet = room temperature
Power Input (50Hz) Fan only / Heating
Dimensions
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections Liquid (OD) / Gas
Power Supply
speed 3 kW
speed 3 °K
kW
mm
mm
mm
kg
mm
speed 3 m3/sec
speed 3 dBA
inch (mm)
Phase / Hz / V
Trade Unit Price
*=C
CYQL150DK200*BN
*=R
15.60
15
0.75 / 0.75
370
370
370
1,000
1,000
1,048
774
1105
745
76
81
83
white RAL9010
520
0.861
53
R-410A
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
*=F
*=C
*=R
23.30
15
1.13 / 1.13
370
370
370
1,500
1,500
1,548
774
1105
745
100
118
141
white RAL9010
520
1.292
54
R-410A
3/8 (9.5) / 3/4 (19)
1 / 50 / 230
CYQL200DK250*BN
*=F
*=C
CYQL250DK250*BN
*=R
29.40
14
1.50 / 1.50
370
370
370
2,000
2,000
2,048
774
1105
745
126
151
155
white RAL9010
520
1.722
56
R-410A
3/8 (9.5) / 7/8 (22.2)
1 / 50 / 230
*=F
*=C
*=R
31.10
12
1.88 / 1.88
370
370
370
2,500
2,500
2,548
774
1105
745
157
190
196
white RAL9010
520
2.153
57
R-410A
3/8 (9.5) / 7/8 (22.2)
1 / 50 / 230
£3,217.00 £3,217.00 £3,226.00 £4,589.00 £4,589.00 £4,737.00 £5,697.00 £5,697.00 £5,993.00 £6,649.00 £6,649.00 £7,016.00
* 2: Mounting Height at base of Door Curtain Air Outlet. F = Free Hanging / C = Cassette / R = Recessed
Condensing Unit Selection for Large Door Curtain
Standard Efficiency
Improved Efficiency
High Efficiency
ERQ125AV1 / AW1
ERQ140AV1
ERQ200AW1
ERQ200AW1
ERQ250AW1
ERQ250AW1
ERQ250AW1
ERQ Condensing Units
Single Phase
Dimensions
Height
Width
Depth
Weight
Pipe Run
Airflow Direction
Trade Unit Price
mm
mm
mm
kg
m
3 Phase
ERQ100AV1
ERQ125AV1
ERQ140AV1
ERQ125AW1
ERQ200AW1
ERQ250AW1
1345
900
320
120
55
Side blow
1345
900
320
120
55
Side blow
1345
900
320
120
55
Side blow
1680
635
765
159
55
Top blow
1680
930
765
187
55
Top blow
1680
930
765
240
55
Top blow
£1,533.00
£1,709.00
£2,049.00
£1,743.00
£3,009.00
£3,135.00
Accessories for all Door Curtains
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV
£76.00
£46.00
£251.00
i)To calculate the price for a complete
system, add together the prices for door
curtain, ERQ and remote controller.
1 off
CYQL100DK125FBN
£4,021.00
1 off
1 off
ERQ125AV1
BRC1E52
£1,709.00
£76.00
Total
£5,806.00
Price List 2016
51
SPLIT, SKY AIR HEAT PUMPS
Central Ducted Solutions
Even without the benefit of individual room control, the system
can provide a flexible energy saving answer over traditional
methods through the incorporation of inverter control and heat
pump technology.
For central ducted distribution systems
Daikin has the solution for providing cooling
and heating of the air, enabling optimal
comfort and efficiency.
The following pages include Packaged Heat Pump Rooftop
systems, with optional economisers, to heat pump condensing
units and connection kits for use with other manufacturers
heating and cooling coils.
Air handling unit
Liquid pipe
Liquid pipe
Gas pipe
Gas pipe
Field supply
EV kit
Control box
F1,F2 communication
DDC control
(control w)
Air Cooled Heat Pump Inverter
Condensing Unit Kit for DX Coil
Flexible control possibilities:
Control w:
Full external control from 3rd party temperature controller with
volt free remote enable contact and linear variable capacity control
output (3rd party DDC Controller required).
A range of R410A inverter condensing units for application
with air handling units:
> Inverter controlled heat pump units
> Large capacity range (from 6.3 to 61.6 kW)
> Ventilation and air conditioning in 1 solution
> EKEXV-kit & control boxes are designed for outdoor installation
and can be wall mounted
> Per EKEXV-kit/control box, only 1 air handling unit coil can
be connected
> Outdoor unit operation range: -5°CDB ~ 43°CDB in cooling
> For connectivity to VRV IV systems, please consult with your local
Daikin representative
Outdoor unit
Trade
Unit Price
3ph
ERQ100AV1
ERQ125AV1
ERQ140AV1
ERQ125AW1
ERQ200AW1
ERQ250AW1
Trade Acc. Price
£1,533.00
£1,709.00
£2,049.00
£1,743.00
£3,271.00
£3,408.00
Control z (BRC1D52 required):
Control via Daikin BRC1D52 remote controller and return air or
remote sensor (KRCS01-1 optional). A volt free remote enable
contact is required to confirm fan operation status. For re-circ
applications only.
Control box
control z
Expansion Valve Kit
control y, w control y, w
class 63
EKEQDCB EKEQFCBA EKEQMCBA EKEXV63
1ph
Control y:
External control from 3rd party temperature controller with volt
free remote enable contact. Fixed evaporating temperature
selection, range: +3°C to +10°C.
P
P
P
P
P
P
P
P
P
P
P
P
£313.00
£361.00
class 80
EKEXV80
class 100
class 125
class 140
class 200
class 250
VRV only
P
P
P
P
-
P
P
P
P
P
-
P
P
P
P
P
P
P
P
P
P
P
P
P
P
P
VRV only
VRV only
£557.00
£70.00
£72.00
£79.00
£86.00
£99.00
£118.00
£132.00
£146.00
£160.00
For all AHU application selections with ERQ and VRV systems, please consult with a member of Daikin staff to ensure
correct selection and AHU coil design parameters.
Residential, Commercial and Industrial
class 500
P
P
P
-
P: Pair Combination depending on air handling units coils volume
52
class 400
EKEXV100 EKEXV125 EKEXV140 EKEXV200 EKEXV250 EKEXV400 EKEXV500
SPLIT, SKY AIR HEAT PUMPS
ERAD-E
Large Condensing Units
Large Condensing Unit (Standard Noise Level)
ERAD120E-SS ERAD140E-SS ERAD170E-SS ERAD200E-SS ERAD220E-SS ERAD250E-SS ERAD310E-SS ERAD370E-SS ERAD440E-SS ERAD490E-SS
Capacity
EER
Refrigerant
Dimensions
Weight
Electrical Details
Nominal Cooling
kW
121
2.89
144
2.82
165
2.87
196
3.01
219
2.97
Length
Height
Width
mm
mm
mm
kg
V
Hz
ph
2170
2.27
1290
1564
2170
2.27
1290
1587
3070
2.27
1290
1698
3070
2.27
1290
1739
3070
2.27
1290
1886
252
3.29
306
3.3
370
3.03
435
2.96
488
3.03
3070
2.27
1290
1928
3070
2220
2240
2355
3070
2220
2240
2559
3070
2220
2240
2642
3070
2220
2240
2677
POA
POA
POA
POA
POA
R134a
Power Supply
400
50
3
Trade Unit Price
POA
POA
POA
POA
POA
Large Condensing Unit (Low Noise Level)
ERAD120E-SL ERAD140E-SL ERAD160E-SL ERAD190E-SL ERAD210E-SL ERAD240E-SL ERAD300E-SL ERAD350E-SL ERAD410E-SL ERAD460E-SL
Capacity
EER
Refrigerant
Dimensions
Weight
Electrical Details
Nominal Cooling
kW
116
2.74
137
2.61
159
2.76
187
2.82
209
2.83
Length
Height
Width
mm
mm
mm
kg
V
Hz
ph
2170
2.27
1290
1712
2170
2.27
1290
1738
3070
2.27
1290
1851
3070
2.27
1290
1897
3070
2.27
1290
2046
243
3.11
295
3.22
352
2.88
409
2.72
462
2.76
3070
2.27
1290
2091
3070
2220
2240
2534
3070
2220
2240
2741
3070
2220
2240
2834
3070
2220
2240
2873
POA
POA
POA
POA
POA
R134a
Power Supply
Trade Unit Price
400
50
3
POA
POA
POA
POA
POA
Features:
ERAD-E are a range of cooling only R134a condensing units for pair
application with air handling units
> Large capacity range 100 kW to 410 kW
> Superior control logic using the new MicroTech III controller
> Single circuit units
> Screw compressor with capacity control down to 25%
> Available in both standard and low noise configurations
Please contact your sales office for further information on these products
UATYQ
Rooftop Packaged Unit – Heat Pump
UATYQ250CY1 UATYQ350CY1 UATYQ450CY1 UATYQ550CY1 UATYQ600CY1 UATYQ700CY1
Capacity
Dimensions
Weight
Air Flow Rate
External Static
Air Flow Rate
Refrigerant
Sound Power Level
Drain size
Electrical Details
Nominal Cooling
Nominal Heating
Height
Width
Depth
Indoor
Indoor
Outdoor
kW
kW
mm
mm
mm
kg
m3/sec
Pa
m3/sec
27.34
24.91
1150
1638
2063
445
1.55
147
0
35.58
34.79
1028
2209
2113
580
2.03
147
0
44.72
41.79
1130
2209
2113
610
2.67
147
0
55.69
53.93
1048
2209
2670
830
3.167
206
0
66.82
61.69
1302
2209
2670
880
3.417
206
0
72.60
69.61
1302
2209
2670
1020
3.883
206
0
UATYPC10AY1
UATYPC12AY1
101.10
102.30
1974
2252
3180
1510
5.20
109.60
126.30
1974
2252
3180
1600
5.90
-
0
R410A
Outdoor
Power Supply
Running Current
Starting Current
Max Fuse Size
dBA
mm
V
Hz
Phase
A
A
A
Trade Unit Price
Economiser
82
83
0
R407C
83
87
90
90
80
80
41.6
144
50
£10,190.00
46.5
148
50
£10,904.00
74.2
175 , 215
125
£14,559.00
82.9
215x2
125
£15,816.00
25.4 (OD)
400
50
3ph
20.5
118
32
£5,027.00
26.4
93
40
£5,234.00
33.1
123
40
£8,612.00
39.4
137
50
£9,476.00
ECONO250AY1 ECONO350AY1 ECONO450AY1 ECONO550AY1 ECONO600AY1 ECONO700AY1
Trade Unit Price
£886.00
£931.00
£976.00
£1,024.00
£1,076.00
£1,129.00
Notes:
i) Minimum Ambient operating conditions
UATYQ250~700
UATYPC10~12
Cooling
Heating
0°C
20°C
-15°C
-15°C
ii) Supplied with remote controller as standard
v)Please check stock & delivery period for all model sizes
iii) Economiser option is supplied as a kit for site assembly
vi) Standard delivery for all units does not include off-loading to kerbside
iv) Low ambient kit for models UATYPC available on request
vii) UATYQ250/350 can be off-loaded by fork-lift if there is one on site
viii)All other units require crane or HIAB. Prices for HIAB available on request
Price List 2016
53
SPLIT, SKY AIR HEAT PUMPS
VRV
Daikin UK Price List 2016
VRV
Indoor Units56
VRV Fan Coil Units
56
Hot Water Connection
63
Air Curtains
66
Outdoor Condensing Units68
VRV Condensing Unit Services
69
VRV Condensing Units – S-series (Mini)
70
VRV Condensing Units – i-series
74
VRV Condensing Units – Heat Pump
76
VRV Condensing Units – Heat Recovery
80
VRV Condensing Units – Replacement VRV-Q
84
DNSS Remote Monitoring
90
VRV-Q Warranty
91
Water Cooled VRV
94
Accessories96
VRV Heat Recovery Branch Selector Boxes
96
Intelligent Manager Building Management System
98
Controls and Apps
100
Refrigerant Leak Detection
107
VRV Cloud Energy Reporting
108
Scottish
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
FXFQ-A
VRV Fan Coil – Roundflow Cassette
Indoor Units
Capacity
VRV
Air Flow Rate
Dimensions
Weight
Electrical Details
Decoration Panel
Decoration Panel
Decoration Panel
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Model
Colour
Dimensions H x W x D
Weight
Model
Colour
Dimensions H x W x D
Weight
Model
Colour
Dimensions H x W x D
Weight
Sound Pressure High
Nom
Low
Sound Power
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
mm
kg
amps
Phase / Hz / V
amps
FXFQ20A
FXFQ25A
1.80
1.60
2.20
2.50
0.208
0.177
0.147
2.30
1.90
2.80
3.20
0.208
0.177
0.147
19
0.3
19
0.3
31.0
29.0
28.0
49
1/4 (6.4)
1/2 (12.7)
£759.00
FXFQ50A
FXFQ63A
4.50
3.60
5.60
6.30
0.250
0.213
0.175
5.70
4.60
7.10
8.00
0.275
0.225
0.175
FXFQ80A
FXFQ100A
7.20
9.00
5.80
6.90
9.00
11.20
10.00
12.50
0.380
0.442
0.293
0.325
0.207
0.207
246x840x840
24
24
0.6
0.8
FXFQ125A
11.30
8.60
14.00
16.00
0.550
0.442
0.332
288x840x840
26
1.3
31.0
29.0
28.0
49
1/4 (6.4)
1/2 (12.7)
43.0
37.0
30.0
60
3/8 (9.5)
5/8 (15.9)
45.0
41.0
36.0
61
3/8 (9.5)
5/8 (15.9)
£774.00
£792.00
£1,095.00
£1,365.00
mm
kg
Trade Unit Price
FXFQ40A
2.90
3.60
2.60
3.00
3.60
4.50
4.00
5.00
0.208
0.227
0.177
0.193
0.147
0.158
204x840x840
19
20
0.3
0.3
21
21
0.4
0.4
1 / 50 / 230
5
Roundflow BYCQ140D (standard panel)
Pure White (RAL 9010)
50x950x950
5.4
Roundflow with white louvres BYCQ140DW
Pure White (RAL 9010)
50x950x950
5.4
Roundflow self cleaning BYCQ140DG
Pure White (RAL 9010)
130x950x950
10.3
31.0
33.0
33.0
35.0
38.0
29.0
31.0
31.0
33.0
34.0
28.0
29.0
29.0
30.0
30.0
49
51
51
53
55
1/4 (6.4)
1/4 (6.4)
1/4 (6.4)
3/8 (9.5)
3/8 (9.5)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
5/8 (15.9)
5/8 (15.9)
mm
kg
mm
kg
dBA
dBA
dBA
dBA
inch (mm)
inch (mm)
FXFQ32A
£855.00
£897.00
£946.00
£1,009.00
Notes:
i) Cassette prices include standard decoration panel - self cleaning panel available as an accessory item
ii)BYCQ140D = pure white panel with grey louvers , BYCQ140DW = pure white standard panel with white louvers, BYCQ140DG = Pure white auto cleaning panel
The BYCQ140DW has white insulations. Be informed that formations of dirt on white insulation is visibly stronger & that it is
consequently not advised to install the decoration panel in environments exposed to concentrations of dirt
iii) For accessories please refer to pages 96 - 108
FXZQ-A
VRV Fan Coil – 600x600 Fully Flat Cassette
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Air Flow Rate
High
Nom
Low
Dimensions (with Decoration Panel)
HxWxD
Weight (with Decoration Panel)
Decoration Panel
Dimensions
Weight
Decoration Panel
Dimensions
Weight
Decoration Panel
Dimensions
Weight
Electrical Details
Running Current
Power Supply
Fuse Rating
Sound Level
Sound Pressure High
Nom
Low
Sound Power
Piping Connections
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
mm
kg
FXZQ15A
FXZQ20A
1.40
1.30
1.70
1.90
0.142
0.117
0.108
1.80
1.50
2.20
2.50
0.145
0.125
0.108
15.5 (18.3)
mm
kg
mm
kg
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
0.3
31.5
29.0
25.5
49
1/4 (6.4)
1/2 (12.7)
£721.00
FXZQ25A
£737.00
£752.00
Notes:
i)Cassette prices include Fully Flat decoration panel in fresh white.
Other colour panels available on request.
56
Residential, Commercial and Industrial
FXZQ32A
FXZQ40A
2.30
2.90
3.60
1.80
2.10
2.90
2.80
3.60
4.50
3.20
4.00
5.00
0.150
0.167
0.192
0.133
0.142
0.158
0.108
0.117
0.133
260 (306) x 575 (620) x 575 (620)
15.5 (18.3)
15.5 (18.3)
16.5 (19.3)
16.5 (19.3)
Fully Flat in white (N9.5) BYFQ60CW (standard panel)
46 x 620 x 620
2.8
Fully Flat in white (N9.5) with silver BYFQ60CS (standard panel)
46 x 620 x 620
2.8
Old style panel BYFQ60B3 (White RAL9010)
55 x 700 x 700
2.7
0.3
0.3
0.4
0.4
1 / 50 / 230
5
32.0
33.0
33.5
37.0
29.5
30.0
30.0
32.0
25.5
25.5
26.0
28.0
49
50
51
54
1/4 (6.4)
1/4 (6.4)
1/4 (6.4)
1/4 (6.4)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
1/2 (12.7)
ii) Dimensions include control box
iii) For accessories please refer to pages 96 - 108
£769.00
£825.00
FXZQ50A
4.50
3.60
5.60
6.30
0.242
0.208
0.167
18.5 (21.3)
0.6
43.0
40.0
33.0
60
1/4 (6.4)
1/2 (12.7)
£906.00
FXCQ-A
VRV Fan Coil – 2 Way Blow Cassette
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Air Flow Rate
High
Nom
Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Decoration Panel
Electrical Details
Running Current
Power Supply
Fuse Rating
Sound Level
Sound Pressure High
Nom
Low
Piping Connections
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
mm
mm
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
FXCQ20A
FXCQ25A
FXCQ32A
FXCQ40A
1.8
1.7
2.2
2.5
0.175
0.150
0.125
305 (360)
775 (1070)
620 (700)
19 (29)
2.3
2.9
2
2.3
2.8
3.6
3.2
4.0
0.192
0.192
0.158
0.158
0.133
0.133
305 (360)
305 (360)
775 (1070)
775 (1070)
620 (700)
620 (700)
19 (29)
19 (29)
BYBCQ40H
0.3
0.3
3.6
2.9
4.5
5.0
0.200
0.175
0.142
305 (360)
775 (1070)
620 (700)
19 (29)
FXCQ50A
FXCQ63A
32.0
30.0
28.0
1/4 (6.4)
1/2 (12.7)
34.0
31.0
29.0
1/4 (6.4)
1/2 (12.7)
34.0
32.0
30.0
1/4 (6.4)
1/2 (12.7)
4.5
5.7
3.5
4.9
5.6
7.1
6.3
8.0
0.250
0.267
0.217
0.233
0.175
0.192
305 (360)
305 (360)
990 (1285)
990 (1285)
620 (700)
620 (700)
22 (33)
25 (36)
BYBCQ63H
0.3
0.4
0.5
1 / 50 / 230
5
36.0
37.0
39.0
33.0
35.0
37.0
31.0
31.0
32.0
1/4 (6.4)
1/4 (6.4)
3/8 (9.5)
1/2 (12.7)
1/2 (12.7)
5/8 (15.9)
£854.00
£869.00
£878.00
£970.00
0.3
£1,061.00
£1,102.00
FXCQ80A
FXCQ125A
7.2
11.3
5.7
8.7
9.0
14.0
10.0
16.0
0.433
0.533
0.375
0.458
0.308
0.375
305 (360)
305 (360)
1445 (1740)
1445 (1740)
620 (700)
620 (700)
33 (46)
38 (51)
BYBCQ125H
0.6
1.1
42.0
38.0
33.0
3/8 (9.5)
5/8 (15.9)
46.0
42.0
38.0
3/8 (9.5)
5/8 (15.9)
£1,265.00
£1,518.00
Notes:
i) Cassette prices include decoration panel
ii) For accessories please refer to pages 96 - 108
FXKQ-MA
VRV Fan Coil – 1 Way Blow Corner Cassette
Indoor Units
Capacity
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
Air Flow Rate
High
Low
Dimensions
Height
(with Decoration Panel) Width
Depth
Weight (with Decoration Panel)
Decoration Panel
Electrical Details
Running Current
Power Supply
Fuse Rating
Sound Level
Sound Pressure High
Low
Piping Connections
Liquid
Gas
Trade Unit Price
kW
kW
kW
kW
m3/sec
m3/sec
mm
mm
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
inch (mm)
inch (mm)
FXKQ25MA
FXKQ32MA
FXKQ40MA
FXKQ63MA
2.3
2.2
2.8
3.2
0.183
0.150
215 (285)
1110 (1240)
710 (800)
31 (39.5)
2.9
2.5
3.6
4.0
0.183
0.150
215 (285)
1110 (1240)
710 (800)
31 (39.5)
BYK45F
0.3
3.6
2.8
4.5
5.0
0.217
0.167
215 (285)
1110 (1240)
710 (800)
31 (39.5)
0.3
5.7
4.5
7.1
8.0
0.300
0.250
215 (285)
1310 (1440)
710 (800)
34 (43.5)
BYK71F
0.5
0.3
1 / 50 / 230
5
38.0
33.0
1/4 (6.4)
1/2 (12.7)
38.0
33.0
1/4 (6.4)
1/2 (12.7)
40.0
34.0
1/4 (6.4)
1/2 (12.7)
42.0
37.0
3/8 (9.5)
5/8 (15.9)
£946.00
£956.00
£1,045.00
£1,185.00
Notes:
i) Cassette prices include decoration panel
ii) For accessories please refer to pages 96 - 108
Price List 2016
57
VRV
Indoor Units
Capacity
FXSQ-A
VRV Fan Coil – Concealed Ceiling Unit (Medium Static)
Indoor Units
Capacity
VRV
Air Flow Rate
External Static Pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
FXSQ15A FXSQ20A FXSQ25A FXSQ32A FXSQ40A FXSQ50A FXSQ63A FXSQ80A FXSQ100A FXSQ125A FXSQ140A
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
High
Low
Height x Width x Depth
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
Pa
Pa
mm
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Nom
Low
Sound Power
Liquid
Gas
kg
23.5
23.5
23.5
24
28.5
29
35.5
36.5
46
47
amps
0.4
0.4
0.4
0.4
0.8
0.8
0.9
1
1.5
2
Phase / Hz / V
1 / 50 / 230
amps
5
dBA
29.5
30.0
30.0
31.0
35.0
35.0
33.0
35.0
36.0
39.0
41.5
dBA
28.0
28.0
28.0
29.0
32.0
32.0
30.0
32.0
34.0
36.0
38.0
dBA
25.0
25.0
25.0
26.0
29.0
29.0
27.0
29.0
31.0
33.0
34.0
dBA
54.0
54.0
54.0
55.0
60.0
60.0
59.0
61.0
61.0
64.0
64.0
inches (mm)
1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 1/4 (6.4) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5) 3/8 (9.5)
inches (mm) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 1/2 (12.7) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9) 5/8 (15.9)
Trade Unit Price
1.4
1.1
1.7
1.9
0.145
0.125
0.108
150
30
1.8
2.3
1.4
1.8
2.2
2.8
2.5
3.2
0.150
0.150
0.125
0.125
0.108
0.108
150
150
30
30
245 x 550 x 800
£580.00
£598.00
2.9
2.3
3.6
4
0.158
0.133
0.117
150
30
£614.00
£622.00
3.6
4.5
2.9
3.6
4.5
5.6
5
6.3
0.250
0.253
0.208
0.208
0.183
0.183
150
150
30
30
245 x 700 x 800
£662.00
£690.00
5.7
7.2
4.5
5.7
7.1
9
8
10
0.350
0.383
0.300
0.325
0.250
0.267
150
150
30
40
245 x 1000 x 800
£712.00
9
11.3
7.2
8.9
11.2
14
12.5
16
0.533
0.600
0.450
0.525
0.383
0.433
150
150
40
50
245 x 1400 x 800
£812.00
12.9
10.2
16
18
0.650
0.567
0.467
150
50
245 x 1550
x 800
51
1.9
£900.00 £1,030.00 £1,133.00
Notes:
i) For accessories please refer to pages 96 - 108
ii) Preliminary Data – May be subject to change
FXMQ-P7
Concealed Ceiling Unit (High Static)
Indoor Units
Capacity
Air Flow Rate
External Static pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
High
Low
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Nom
Low
Sound Power
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
Pa
Pa
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
Notes:
i) For accessories please refer to pages 96 - 108
58
Residential, Commercial and Industrial
FXMQ50P7
FXMQ63P7
FXMQ80P7
FXMQ100P7
FXMQ125P7
4.5
4.1
5.6
6.3
0.300
0.275
0.250
200
100
7.2
6.1
9
10
0.417
0.375
0.333
200
100
9
7.3
11.2
12.5
0.533
0.458
0.383
200
100
11.3
9.2
14
16
0.650
0.558
0.467
200
100
35
1.4
5.7
4.9
7.1
8
0.325
0.297
0.267
200
100
300 x 1000 x 700
35
1.4
46
2.3
46
2.9
41.0
39.0
37.0
61.0
1/4 (6.4)
1/2 (12.7)
42.0
40.0
38.0
64.0
3/8 (9.5)
5/8 (15.9)
35
1.7
1 / 50 / 230
5
43.0
41.0
39.0
67.0
3/8 (9.5)
5/8 (15.9)
43.0
41.0
39.0
65.0
3/8 (9.5)
5/8 (15.9)
44.0
42.0
40.0
70.0
3/8 (9.5)
5/8 (15.9)
£1,066.00
£1,117.00
£1,174.00
£1,301.00
£1,489.00
300 x 1400 x 700
FXDQ-A
Slim Concealed Ceiling Unit
Air Flow Rate
External Static Pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
FXDQ15A
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
High
Low
Height x Width x Depth
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
Pa
Pa
mm
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Nom
Low
Liquid
Gas
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
1.4
1.3
1.7
1.9
0.125
0.117
0.107
30
10
FXDQ20A
FXDQ25A
1.8
2.3
1.6
1.9
2.2
2.8
2.5
3.2
0.133
0.133
0.120
0.120
0.107
0.107
30
30
10
10
200 x 750 x 620
FXDQ32A
FXDQ40A
FXDQ50A
26
0.5
26
0.5
33.0
31.0
27.0
1/4 (6.4)
1/2 (12.7)
22
0.4
1 / 50 / 230
5
33.0
31.0
27.0
1/4 (6.4)
1/2 (12.7)
34.0
32.0
28.0
1/4 (6.4)
1/2 (12.7)
35.0
33.0
29.0
1/4 (6.4)
1/2 (12.7)
36.0
34.0
30.0
3/8 (9.5)
5/8 (15.9)
£597.00
£605.00
£644.00
£670.00
£691.00
22
0.4
22
0.4
32.0
31.0
27.0
1/4 (6.4)
1/2 (12.7)
33.0
31.0
27.0
1/4 (6.4)
1/2 (12.7)
£562.00
£579.00
3.6
4.5
2.8
3.5
4.5
5.6
5
6.3
0.175
0.208
0.158
0.183
0.142
0.167
44
44
15
15
200 x 950 x 620
FXDQ63A
5.7
4.3
7.1
8
0.275
0.242
0.217
44
15
200 x 1150
x 620
29
0.6
22
0.4
2.9
2.2
3.6
4
0.133
0.120
0.107
30
10
VRV
Indoor Units
Capacity
Notes:
i) For accessories please refer to pages 96 - 108
ii) Fan coils supplied as standard with factory fitted filter
FXDQ-M9
Small Concealed Ceiling Unit
Indoor Units
Capacity
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Low
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Nom
Sound Power
Liquid
Gas
Trade Unit Price
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
inch (mm)
inch (mm)
FXDQ20M9
FXDQ25M9
1.8
1.6
2.2
2.5
0.112
0.087
2.3
1.9
2.8
3.2
0.123
0.097
230 x 652 x 502
17
0.2
17
0.2
1 / 50 / 230
5
37.0
32.0
50
1/4 (6.4)
1/2 (12.7)
37.0
32.0
50
1/4 (6.4)
1/2 (12.7)
£579.00
£597.00
Notes:
i) For accessories please refer to pages 96 - 108
ii) Fan coils supplied as standard with factory fitted filter
Price List 2016
59
FXMQ-MB
VRV Fan Coil – Concealed Ceiling Unit (Ultra High Static)
Indoor Units
Capacity
VRV
Air Flow Rate
External Static pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
High
Nom
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Low
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
Pa
Pa
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
inch (mm)
inch (mm)
FXMQ200MB
FXMQ250MB
18
14.9
22.4
25
0.967
0.900
0.833
270
160
22.5
18.5
28
31.5
1.200
1.117
1.033
270
170
470 x 1380 x 1100
132
10.3
132
10.3
1 / 50 / 230
13
Trade Unit Price
48.0
45.0
3/8 (9.5)
3/4 (19)
48.0
45.0
3/8 (9.5)
7/8 (22.2)
£2,601.00
£2,662.00
Notes:
i) For accessories please refer to pages 96 - 108
FXAQ-P
VRV Fan Coil – Wall Mounted
Indoor Units
Capacity
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
FXAQ15P
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Low
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Low
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
Notes:
i) For accessories please refer to pages 96 - 108
60
Residential, Commercial and Industrial
1.4
1.4
1.7
1.9
0.117
0.075
11
0.3
FXAQ20P
FXAQ25P
1.8
2.3
1.8
2
2.2
2.8
2.5
3.2
0.125
0.133
0.075
0.083
290 x 795 x 238
11
11
0.3
0.4
FXAQ32P
FXAQ40P
FXAQ50P
FXAQ63P
2.9
2.4
3.6
4
0.142
0.092
3.6
3.3
4.5
5
0.200
0.150
5.7
4.6
7.1
8
0.317
0.233
14
0.4
4.5
3.7
5.6
6.3
0.250
0.200
290 x 1050 x 238
14
0.5
39.0
34.0
1/4 (6.4)
1/2 (12.7)
42.0
36.0
1/4 (6.4)
1/2 (12.7)
47.0
39.0
3/8 (9.5)
5/8 (15.9)
£481.00
£507.00
£559.00
34.0
29.0
1/4 (6.4)
1/2 (12.7)
35.0
29.0
1/4 (6.4)
1/2 (12.7)
36.0
29.0
1/4 (6.4)
1/2 (12.7)
11
0.4
1 / 50 / 230
5
37.5
29.0
1/4 (6.4)
1/2 (12.7)
£439.00
£452.00
£464.00
£469.00
14
0.6
FXHQ-A
Indoor Units
Capacity
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Nom
Low
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
FXHQ32A
FXHQ63A
FXHQ100A
2.9
2.3
3.6
4
0.233
0.200
0.167
235 x 960 x 690
24
0.8
9
6.3
11.2
12.5
0.492
0.400
0.317
235 x 1590 x 690
39
1.7
36.0
34.0
31.0
1/4 (6.4)
1/2 (12.7)
5.7
4.4
7.1
8
0.333
0.283
0.233
235 x 1270 x 690
33
0.8
1 / 50 / 230
5
37.0
35.0
34.0
3/8 (9.5)
5/8 (15.9)
£906.00
£1,004.00
£1,246.00
VRV
VRV Fan Coil – Ceiling Suspended
44.0
37.0
34.0
3/8 (9.5)
5/8 (15.9)
Notes:
i) For accessories please refer to pages 96 - 108
FXUQ-A
VRV Fan Coil – Under Ceiling Cassette
Indoor Units
Capacity
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Nom
Low
Liquid
Gas
Trade Unit Price
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
inch (mm)
inch (mm)
FXUQ71A
FXUQ100A
6.4
5.2
8.0
9.0
0.375
0.325
0.267
9
7
11.2
12.5
0.517
0.433
0.350
198 x 950 x 950
26
0.6
27
1.4
1 / 50 / 230
5
40.0
38.0
36.0
3/8 (9.5)
5/8 (15.9)
47.0
44.0
40.0
3/8 (9.5)
5/8 (15.9)
£1,254.00
£1,337.00
Notes:
i) For accessories please refer to pages 96 - 108
Price List 2016
61
FXLQ-P
VRV Fan Coil – Floor Mounted Cased
Indoor Units
Capacity
VRV
Air Flow Rate
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
FXLQ20P
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Low
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Low
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
FXLQ25P
1.8
2.3
1.5
1.8
2.2
2.8
2.5
3.2
0.117
0.117
0.100
0.100
600 x 1000 x 232
27
27
0.3
0.3
FXLQ32P
FXLQ40P
35.0
32.0
1/4 (6.4)
1/2 (12.7)
35.0
32.0
1/4 (6.4)
1/2 (12.7)
2.9
3.6
2.2
2.7
3.6
4.5
4.0
5.0
0.133
0.183
0.100
0.142
600 x 1140 x 232
32
32
0.6
0.6
1 / 50 / 230
5
35.0
38.0
32.0
33.0
1/4 (6.4)
1/4 (6.4)
1/2 (12.7)
1/2 (12.7)
£695.00
£706.00
£720.00
FXLQ50P
FXLQ63P
4.5
5.7
3.4
4.2
5.6
7.1
6.3
8.0
0.233
0.267
0.183
0.200
600 x 1420 x 232
38
38
0.6
0.6
39.0
34.0
1/4 (6.4)
1/2 (12.7)
40.0
35.0
3/8 (9.5)
5/8 (15.9)
£746.00
£754.00
£799.00
Notes:
i) For accessories please refer to pages 96 - 108
FXNQ-A
VRV Fan Coil – Concealed Floor Standing Unit
Indoor Units
Capacity
Air Flow Rate
External Static Pressure
Dimensions
Weight
Electrical Details
Sound Level
Piping Connections
UK Total Cooling
UK Sensible Cooling
Nominal Cooling
Nominal Heating
High
Nom
Low
High
Nominal
Height x Width x Depth
Running Current
Power Supply
Fuse Rating
Sound Pressure High
Nom
Low
Liquid
Gas
kW
kW
kW
kW
m3/sec
m3/sec
m3/sec
Pa
Pa
mm
kg
amps
Phase / Hz / V
amps
dBA
dBA
dBA
inch (mm)
inch (mm)
Trade Unit Price
FXNQ20A
FXNQ25A
FXNQ32A
FXNQ40A
FXNQ50A
FXNQ63A
1.8
1.6
2.2
2.5
0.133
0.120
0.107
41
10
2.3
1.9
2.8
3.2
0.133
0.120
0.107
41
10
620 x 750 x 200
23.5
0.4
2.9
2.2
3.6
4
0.133
0.120
0.107
42
10
3.6
2.8
4.5
5
0.175
0.158
0.142
52
15
4.5
3.5
5.6
6.3
0.208
0.183
0.167
59
15
23.5
0.4
27.5
0.5
27.5
0.5
5.7
4.3
7.1
8
0.275
0.242
0.217
55
15
620 x 1150 x 200
32
0.6
23.5
0.4
620 x 950 x 200
1 / 50 / 230
5
30.0
28.5
27.0
1/4 (6.4)
1/2 (12.7)
30.0
28.5
27.0
1/4 (6.4)
1/2 (12.7)
30.0
28.5
27.0
1/4 (6.4)
1/2 (12.7)
32.0
30.0
28.0
1/4 (6.4)
1/2 (12.7)
33.0
31.0
29.0
1/4 (6.4)
1/2 (12.7)
35.0
33.0
32.0
3/8 (9.5)
5/8 (15.9)
£649.00
£659.00
£673.00
£697.00
£704.00
£748.00
Increased static pressure – up to 59Pa
Notes:
i) For accessories please refer to pages 96 - 108
ii) Supplied with removable feet
62
Residential, Commercial and Industrial
HXY-A8
Hot Water Generation – VRV Heat Pump Systems
VRV
Producing hot water from a heat pump system provides
extremely low cost heating and cooling of water.
Temperatures between 5°C to 45°C can be achieved
allowing water temperature control for multiple
applications without the need for a separate system.
HXY-A8
Features and benefits:
> H
ighly efficient space heating/cooling
> Air to water connection to VRV for applications such as
underfloor, AHU, low temperature radiators
> Leaving water temperature range from 5°C to 45°C without
electric heater
> Super wide operating range for cold/hot water production from
-20°C to +43°C ambient outdoor temperature
> Saves time on system design as all water-side components
are fully integrated with direct control over leaving water
temperature
> Saves space with contemporary wall hung design
> Requires no gas connection or oil tank
Liquid pipe
Gas pipe
Hot/cold water
VRV indoor units
Air handling unit
VRV IV heat pump
Low temp. radiator
HXY-A8 Low
temperature
hydrobox
Under floor heating
Indoor unit
Cooling capacity
Heating capacity
Casing
Dimensions
Weight
Sound pressure level
Operation range
Refrigerant
Refrigerant circuit
Water circuit
Power supply
Recommended fuses
Trade Unit Price
Nom.
Nom.
Colour
Material
Unit
Unit
Nom.
Heating
kW
kW
Height x Width x Depth
Ambient
Water side
Min.~Max.
Min.~Max.
Type
Liquid
Gas
Piping connections diameter
HXY080A8
HXY125A8
8.0
9.0
12.5
14.0
White
Precoated sheet metal
890x480x344
44
-20~24
25~45
R-410A
3/8 (9.5)
5/8 (15.9)
G 1”1/4 (female)
1 / 50 / 230
5
mm
kg
dBA
°C
°C
inch (mm)
inch (mm)
inch
Phase / Hz / V
A
£1,461.00
£2,050.00
Price List 2016
63
HXHD-A8 / HXY-A8
Hot Water Generation – VRV Heat Recovery Systems
VRV
Producing hot water from a heat recovery VRV system
is one of the most energy efficient means of providing
hot water within a building. We can provide high
and low temperature hot water for bathrooms, wash
basins, underfloor heating, radiators and even provide
heated water for air handling unit applications.
HXHD-A8 (High temperature)
Using waste heat to provide hot water means you can provide
an additional service to your building from the heat recovery VRV
system at very low cost.
Features and benefits:
For both low temperature and high temperature
> Uses heat pump technology to produce hot water efficiently,
providing up to 17% savings compared to a gas boiler
> Saves time on system design as all water-side components
are fully integrated with direct control over leaving water
temperature
> Requires no gas connection or oil tank
HXY-A8 (Low temperature)
For low temperature
> Highly efficient space heating/cooling
> Leaving water temperature range from 5°C to 45°C without
electric heater
> Super wide operating range for cold/hot water production from
-20°C to +43°C ambient outdoor temperature
> Saves space with contemporary wall hung design
For high temperature
> Possibility to connect thermal solar collectors to the domestic
hot water tank
> Leaving water temperature range from 25°C to 80°C without
electric heater
> Various control possibilities with weather dependant set point
or thermostat control
45°C - 75°C
Domestic hot water
VRV indoor units
VRV heat recovery with
connection to heating only
hydrobox (REYQ-T)
EKHTSU-AC
EKHWP-(P)B*
25°C - 75°C
Air handling unit
BS-Box
45°C - 75°C
Low temp. radiator
BS-Box
Heating only
hydrobox for VRV
25°C - 35°C
Liquid pipe
Gas pipe
Discharge gas pipe
Hot/cold water
BS-Box
Hot/cold water
*PB for pressurised solar, B with drainback solar.
64
Residential, Commercial and Industrial
HXY-A8 Low
temperature
hydrobox
Under floor heating
HXHD-A8 / HXY-A8
Hot Water Generation – VRV Heat Recovery Systems
Indoor unit
HXHD125A8
HXY080A8
High Temperature
Dimensions
Weight
Sound pressure
level
Operation range
Nom.
Nom.
Colour
Material
Unit
Unit
Nom.
Night quiet mode
Heating
Domestic hot water
Refrigerant
Refrigerant circuit
Water circuit
Power supply
Current
kW
kW
14.0
Metallic grey
8
9
12.5
14
White
Precoated sheet metal
Height x Width x Depth
Level 1
Ambient
Water side
Ambient
Water side
Type
Liquid
Gas
Piping connections diameter
Heating water system
Water volume
Recommended fuses
Trade Unit Price
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
Min.~Max.
mm
kg
dBA
dBA
°C
°C
°CDB
°C
inch (mm)
inch (mm)
inch
l
Phase / Hz / V
A
705x600x695
92
42 (1) / 43 (2)
38 (1)
-20~20 / 24 (3)
25~80
-20~43
45~75
R-134a
3/8 (9.5)
1/2 (12.7)
G 1” (female)
20~200
1 / 50 / 230
20
£2,713.00
890x480x344
44
VRV
Cooling Capacity
Heating capacity
Casing
HXY125A8
Low Temperature
-20~24
25~45
R-410A
3/8 (9.5)
5/8 (15.9)
G 1” 1/4(female)
1 / 50 / 230
5
£1,461.00
£2,050.00
(1) Sound levels are measured at: EW 55°C; LW 65°C (2) Sound levels are measured at: EW 70°C; LW 80°C (3) Field setting
Notes:
i)Hydroboxes are connectable to the following outdoor series only: Air Cooled Heat Recovery REYQ-T (see page 80)
ii)Hydroboxes are inclusive of integral expansion vessel, and pump
EKHTSU-AC
HT Water Tank
Domestic Unvented Hot Water Tank
Energy Efficiency Class
Standing Heat Loss
Water Volume
Max Water Temperature
Height
Width
Depth
Empty Weight
Colour
Material Inside Tank
Material Outside Casing
Piping Connections
Water inlet H/E
(Diameter)
Water outlet H/E
Cold Water in
Hot water out
Trade Unit Price
EKHTSU200AC
W
l
°C
mm
mm
mm
kg
mm
mm
inch
inch
EKHTSU260AC
Unvented System (Includes EKUHWHT unvented Kit as shown below)
B
B
50
63
200
260
75
1335
1610
600
600
695
695
70
78
Metallic grey
Stainless Steel
Precoated sheet metal
25 (female quick coupling supplied)
25 (female quick coupling supplied)
3/4” (female)
3/4” (female)
£1,121.00
£1,269.00
Accessories:
Notes:
Accessories For Unvented Systems
Trade Unit Price
EKUHWHT
Included with
EKHTSU*AC
£277.00
EKFMAHTB
Includes: Combined Pressure Reducing Valve, Non Return Valve, Strainer, Expansion Relief Valve,
Expansion Vessel, Tundish
Option for stand alone tank (ie not mounted on top of hydrobox)
i)Hydroboxes are connectable to the
following outdoor series only: Air Cooled
Heat Recovery REYQ-T (see page 80)
ii)Hydroboxes are inclusive of integral
expansion vessel and pump
Price List 2016
65
CYVS/M/L - DK - F/C/R
In conjunction with Biddle, Daikin VRV IV heat recovery air
curtain solutions combines the benefits of the Biddle air curtain
technology with the benefits of Daikin VRV IV heat recovery.
Using a combination of rectifier technology, air velocity and
temperature control they deliver greater comfort to staff and
customers alike, all year round, in all weathers.
Easy and fast installation of these systems not only reduces costs
but makes expensive water systems, boilers and gas connections
redundant. Integrating a Biddle air curtain with Daikin VRV also
eliminates the need to install multiple outdoor units thereby
reducing installation time and costs further. This combination
enables Daikin to offer its customers the ultimate environmentally
conscious TOTAL SOLUTION PACKAGE comprising cooling, heating,
outdoor-indoor climate separation and fresh air ventilation.
Some air curtains may be ECA compliant please see
ECA website for details www.daikin.co.uk/ECA
Features and benefits:
>
>
>
>
>
>
>
>
>
rovides virtually free air curtain heating via recovered heat from indoor units in cooling mode
P
Connection to the high COP heat recovery system enables COP’s of up to 4.36
Short payback times – less than 3 years
Air curtain rectifier technology – deeply penetrating airstream
Constant air velocity technology – all year round efficiency
European patent
1.0, 1.5, 2.0 and 2.5 metre door widths
Door heights of up to 3.7 metres
Choice of colour RAL9010:White or RAL9006:Grey
F = Free hanging model
C = Cassette model
R = Recessed model
Biddle Comfort air curtain range
Selection
3.7m
4m
Maximum door height (m)
VRV
Air curtains are the ideal solution to combat the issue of
climate separation across retail outlets or office doorways.
3.2m
3m
2.8m
2.7m
3.1m
2.35m
2.0m
2.3m
2.5m
2m
2) W
hen you know the size (S/M/L),
refer to specific tables to select the
model for your required door width
1m
S
M
L
S
M
L
S
M
L
Installation condition
Ideal for doors in a shopping
centre or revolving door entrance
66
1) U
se the Door Height graph to
determine the Air Curtain size
relevant to your application
For more exposed doors with
some direct wind, suitable for
ground floor applications
Residential, Commercial and Industrial
For areas exposed to higher wind
speeds i.e. open stairwell or balcony
door at higher than ground level
CYVS/M/L - DK - F/C/R
Biddle Standard Air Curtain – SMALL – Door Height 2.7m to 2m
Maximum Door Width
m
Mounting Height *2
Max / Min
1.0
1.5
Model name
Heating capacity
speed 3 kW
Delta T
Inlet = room temperature speed 3 °K
Power input (50Hz) Fan only / Heating
kW
Dimensions
Height
mm
Width
mm
Depth
mm
kg
Casing
Colour
Minimum requiring ceiling void
*=F
*=C
270
1,000
590
7.40
15
0.23/0.23
270
1,000
891
56
59
*=R
CYVS150DK80*BC
*=F
*=C
270
1,048
561
270
1,500
590
9.00
15
0.35/0.35
270
1,500
821
61
66
83
CYVS200DK100*BC
*=R
*=F
*=C
270
1,548
561
270
2,000
590
11.60
15
0.46/0.46
270
2,000
821
88
83
102
*=R
CYVS250DK140*BC
*=F
*=C
*=R
270
2,048
561
270
2,500
590
16.20
16
0.58/0.58
270
2,500
821
270
2,548
561
108
107
129
137
white RAL9010
mm
Fan - Air flow rate
Heating
speed 3 m3/sec
Sound pressure
Refrigerant
Heating
Type
speed 3 dBA
Piping connections Liquid (OD) / Gas
Power supply
2.5
2.7 / 2.0
CYVS100DK80*BC
Type
Weight
2.0
m
420
420
420
420
0.323
0.485
0.647
0.808
47
49
50
51
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 3/4 (19)
R-410A
inch (mm)
Phase / Hz / V
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
£2,486.00 £2,456.00 £2,560.00 £3,167.00 £3,136.00 £3,311.00 £3,827.00 £3,798.00 £4,103.00 £4,270.00 £4,240.00 £4,575.00
Trade Unit Price
M Biddle Standard Air Curtain – MEDIUM – Door Height 3.2m to 2.3m
Maximum Door Width
m
Mounting Height *2
Max / Min
1.0
Model name
*=F
Heating capacity
speed 3 kW
Delta T
Inlet = room temperature speed 3 °K
Power input (50Hz) Fan only / Heating
kW
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
mm
mm
mm
kg
Heating
speed 3 m3/sec
Sound pressure
Refrigerant
Heating
Type
speed 3 dBA
Piping connections Liquid (OD) / Gas
Power supply
2.5
*= R
CYVM150DK80*BC
*=F
*=C
CYVM200DK100*BC
*=R
*=F
*=C
*=R
CYVM250DK140*BC
*=F
*=C
9.20
11.00
13.40
19.90
17
0.37/0.37
14
0.56/0.56
13
0.75/0.75
15
0.94/0.94
270
1,000
821
270
1,048
561
270
1,500
590
270
1,500
821
57
68
66
73
88
270
1,548
561
270
2,000
590
93
94
white RAL9010
*=R
270
2,000
821
270
2,048
561
270
2,500
590
270
2,500
821
270
2,548
561
111
117
108
136
144
420
420
420
420
0.446
0.669
0.892
1.115
50
51
53
54
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 3/4 (19)
R-410A
inch (mm)
Phase / Hz / V
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 5/8 (15.9)
1 / 50 / 230
£2,844.00 £2,813.00 £2,919.00 £3,644.00 £3,613.00 £3,773.00 £4,514.00 £4,484.00 £4,788.00 £5,137.00 £5,108.00 £5,436.00
Trade Unit Price
L
*=C
270
1,000
590
mm
Fan - Air flow rate
2.0
3.2 / 2.3
CYVM100DK80*BC
Type
Dimensions
1.5
m
Biddle Standard Air Curtain – LARGE – Door Height 3.7m to 2.5m
Maximum Door Width
m
Mounting Height *2
Max / Min
1.0
1.5
Model name
speed 3 kW
speed 3 °K
kW
mm
mm
mm
kg
mm
speed 3 m3/sec
speed 3 dBA
2.5
3.7 / 2.5
CYVL100DK125*BC
Type
Heating Capacity
Delta T
Inlet = room temperature
Power Input (50Hz) Fan only / Heating
Dimensions
Height
Width
Depth
Weight
Casing
Colour
Minimum requiring ceiling void
Fan - Air Flow Rate Heating
Sound Pressure
Heating
Refrigerant
Type
Piping Connections Liquid (OD) / Gas
Power Supply
2.0
m
*=F
*=C
370
1,000
774
76
15.6
15
0.75 / 0.75
370
1,000
1105
81
*=R
370
1,048
745
83
CYVL150DK200*BC
*=F
*=C
370
1,500
774
100
23.3
15
1.13 / 1.13
370
1,500
1105
118
CYVL200DK250*BC
*=R
*=F
370
370
1,548
2,000
745
774
141
126
white RAL9010
520
0.861
53
520
1.292
54
3/8 (9.5) / 5/8 (15.9)
3/8 (9.5) / 3/4 (19)
*=C
29.4
14
1.50 / 1.50
370
2,000
1105
151
*=R
370
2,048
745
155
CYVL250DK250*BC
*=F
*=C
*=R
370
2,500
774
157
31.1
12
1.88 / 1.88
370
2,500
1105
190
370
2,548
745
196
520
1.722
56
520
2.153
57
3/8 (9.5) / 7/8 (22.2)
3/8 (9.5) / 7/8 (22.2)
R-410A
inch (mm)
Phase / Hz / V
1 / 50 / 230
£3,623.00 £3,585.00 £3,696.00 £4,820.00 £4,783.00 £4,932.00 £5,935.00 £5,897.00 £6,193.00 £6,892.00 £6,855.00 £7,219.00
Trade Unit Price
Accessories:
Notes:
Accessory Ref
Description
Trade Price
BRC1E52A
KRCS01-1
RTD-20/UK.FB2
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
Remote room mounted temperature sensor
Energy control PCB for Sky Air and VRV
£76.00
£46.00
£251.00
*2: Mounting Height at base of door curtain air outlet F = Free Hanging / C = Cassette / R = Recessed
i)Biddle Remote Controller and connection
cable included for Fan Speed Control
ii)If RTD-20 Connected in Air Curtain mode the
Biddle Remote Controller is NOT connected
as Fan speed is managed by RTD-20
iii)Code “BC” is for white finish. Aluminium
finish “SC”available on request
Price List 2016
67
VRV
S
The VRV Total Solution
VRV
Many buildings today typically operate quite separate systems
for heating, cooling, refrigeration and hot water. As a result,
a huge amount of energy is wasted. To provide a much more
efficient alternative, VRV technology has been developed into a
total solution for heating, cooling, refrigeration and ventilation.
The VRV total solution
Air conditioning, refrigeration and cooling IT servers can generate
waste heat that can be reused to heat and ventilate other areas
of the building or to provide hot water for wash rooms, at a much
reduced cost.
By understanding the whole building’s heating and cooling
needs at the outset, an integrated climate control solution can be
delivered that offers much higher energy efficiency levels, thus
reducing the carbon impact of a building. This means that all
internal and external conditions must be taken into account in the
design of the climate control system.
NEW
Extended piping range
> Increased efficiency and versatility.
> V
RV IV Heat Recovery systems have received an upgraded piping capability
which allows fan coils to be spread over 10 floors on the same system.
> N
ow it is possible to have up to 30m height separation between indoor
units, allowing even more versatility than ever before and allowing heat
recovery between more floors.
Piping Rules
Maximum pipe length from
Condenser to furthest indoor unit
Maximum distance from 1st Refnet
joint to furthest fan coil
Maximum total pipework length
(VRV Fan coils)
Maximum difference from indoor
unit to its own refnet
Maximum Height difference
between Outdoor and Indoor
Maximum Height difference
between indoor units
Heat
Recovery
Heat Pump
Mini
Compact
Mini
Standard
Mini
Extended
VRVQ
VRV-W
8-54 hp
8-54 hp
4, 5 hp
4, 5, 6 hp
8, 10, 12 hp
8-48 hp
8-30 hp
165m
165m
70m
120m
100m
120m
120m
90m
90m
40m
40m
40m
40m
90m*
1000m
1000m
300m
300m
300m
300m
300m
40m
40m
40m
40m
40m
40m
40m
90m
90m
30m
40-50m*
40-50m*
40-50m*
40-50m*
30m
30m
tbc
tbc
tbc
15m
15m
Note:
* 40m if condenser is below indoors - 50m if condenser above indoors
Not all limitations are shown for every combination of indoor units
Some limitations cannot be used together on the same system
Some limitations require approval
Please contact Daikin UK for more details on pipework design
68
Residential, Commercial and Industrial
VRV
VRV Services
Strip Down and Rebuild
Our Strip and Rebuild Service offers you the benefit
of time and cost savings, as it means that you can
have VRV outdoor units delivered to site in portable
components, so they can be transported to the roof
without the need for cranes or applying for road
closure permissions.
PRICE ON APPLICATION
Lead time: 3 weeks
Applicable condensers: VRV, CVP, Zeas
How it works:
> O
ur engineers will strip down and package the components
securely in a purpose built container at our workshop
> W
e then organise delivery to the kerb-side on site where the
contractor can unload, lift and manoeuvre the units into place
> O
ur engineers will then attend site to rebuild, pressure test,
and vacuum and charge the unit with refrigerant ready for
connection to the rest of the system
> If the unit is to be kept on site for any period of time, please
ensure the container is kept dry and is not opened.
When asking for a quotation or ordering, please state the unit you
require and also that you require the strip and rebuild service.
Painted Units
Customers sometimes require visible units to be less
obtrusive, whether for aesthetic or planning reasons.
Daikin UK offer a customised service where we can repaint our
units to any specified RAL or BS finish. Our repainting service is
done in house in our purpose built facility and includes removing
base paint to give a uniform, long lasting and professional finish.
We have repainted fan coils, decoration panels, BS boxes and all
types of condensers for a number of clients.
PRICE ON APPLICATION
Lead time: 2-3 weeks
Applicable units: All
When asking for a quotation or ordering, please state the unit you
require along with the finish requirements e.g. colour, pattern etc.
Please note:
The stated lead times are a guide, this can be influenced by the design and
complexity of the requirement.
Price List 2016
69
VRV IV S Series –
New Extended Range
Now with:
VRV
Low Height compact 4 & 5 hp
1 Phase
> V
ariable Refrigerant Temperature
> AHU connection
> Air curtain connection
Standard 4, 5 & 6 hp
1 Phase and 3 Phase
823mm
1615mm
Large Capacity 8, 10 & 12 hp
3 Phase
10/12 hp
70
Residential, Commercial and Industrial
8 hp
4/5/6 hp
4/5 hp
VRV IV S-series – RXYSCQ-T
VRV IV Condensing Unit – Low Height Compact Mini VRV
Outdoor Units
Power Input 50Hz
Nominal Cooling
Nominal Heating
Cooling
Heating
EER
COP
Dimensions
Height x Width x Depth
Weight
Refrigerant Circuit
Refrigerant Type
Sound Pressure (Nom)
Cooling
Sound Power (Nom)
Cooling
Maximum No of Connectable Units
Electrical Details
Power Supply
Running Current
Starting Current
Fuse Rating
Piping Limits
Total Piping length
Maximum Length
Maximum Vertical Rise
Piping Connections
Liquid
Gas
Capacity Index Limit
RXYSCQ4TV1
RXYSCQ5TV1
12.1
12.1
3.43
3.18
3.53
3.81
14
14
4.26
3.91
3.29
3.58
kW
kW
kW
kW
mm
kg
823 x 940 x 460
94
VRV
Capacity
94
R410A
dBA
dBA
51
68
8
Phase / Hz / V
amps
amps
amps
m
m
m
inch (mm)
inch (mm)
Trade Condensing Unit Price
52
69
10
1 / 50 / 230
19.0
4
32
300
70 (90 equivalent)
30
3/8 (9.5)
5/8 (15.9)
50~130
3/8 (9.5)
5/8 (15.9)
62.5~162.5
£2,462.00
£2,767.00
823mm high
Less than 1m
>New low height Mini VRV, making complying with planning
restrictions in towns and cities easier
> Compact – only 823mm high
> Lightweight – for simple installation
> Variable Refrigerant temperature – enhanced efficiency
> In addition to VRV fan coils, low height Mini VRV is connectable to:
Stylish indoor units – Emura and Nexura – as well as Air Handling
Units and Biddle Air Curtains
> Single phase
Parapet wall
Features:
Roof
Planning issues for small commercial or residential projects in
towns and cities can now be easy to overcome with a Low
height version of the mini VRV range, available in 4 & 5hp with
Variable Refrigerant Temperature. Connectable to products
such as Air Curtains, Air Handling Units and the Emura and
Nexura fan coils, the Low height Mini VRV range brings a
whole new level of versatility to the VRV range.
Daikin VRV IV S-series units can be
installed discreetly on a balcony
thanks to their compact dimensions,
offering you air conditioning while
being almost unnoticeable.
Price List 2016
71
VRV IV S-series – RXYSQ-T
VRV IV Condensing Units – Standard Mini VRV
Outdoor Units
VRV
Capacity
EER
COP
Dimensions
Weight
Air Flow Rate
Electrical Details
Nominal Cooling
Nominal Heating
kW
kW
Height x Width x Depth
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Circuit
Sound Pressure (Nom)
Sound Power (Nom)
Piping Limits
Piping Connections
Maximum Length
Liquid
Gas
RXYSQ4TV1
RXYSQ5TV1
RXYSQ6TV1
RXYSQ4TY1
RXYSQ5TY1
RXYSQ6TY1
12.1
12.1
4.00
4.52
14.0
14.0
3.75
4.28
15.5
15.5
3.40
3.90
12.1
12.1
4.00
4.52
14.0
14.0
3.75
4.28
15.5
15.5
3.40
3.90
4.44
3 / 50 / 380~415
5.55
6.84
1345 x 900 x 320
104
1.767
14.0
1 / 50 / 230
17.3
21.2
4
32A
16A
R410A
dBA
dBA
m
inch (mm)
inch (mm)
50
68
51
69
51
70
50
68
51
69
51
70
300
3/8 (9.5)
Capacity Index Limit
Maximum Number of Connected Indoor Units
5/8 (15.9)
50 - 130
8
5/8 (15.9)
62.5 - 162.5
10
3/4 (19)
70 -182
12
5/8 (15.9)
50 - 130
8
5/8 (15.9)
62.5 - 162.5
10
3/4 (19)
70 -182
12
Trade Condensing Unit Price
£2,735.00
£3,074.00
£3,431.00
£2,788.00
£3,160.00
£3,510.00
Technologies
Refrigerant-cooled PCB
> R
eliable cooling because it is
not influenced by ambient air
temperature
> S maller switchbox for
smoother air flow through the
heat exchanger increasing heat
exchange efficiency with 5%
Features
Super aero grille
The spiral shaped ribs are aligned with
the direction of discharge flow in order to
minimise turbulence and reduce noise.
Improved fan blades
Old
New
Vane fixed to rotor
Rotor
Separate
Collision
Compressor
Swing type > no oil separator
Vane & rotor are unified resulting in:
> Reduced noise level
> Longer compressor life
> Higher efficiency
Air streams
are smoothed around V-cut
and reduces air flow loss
Air streams
collide and
generate loss
E-Pass heat exchanger
Optimising the heat exchanger’s path layout prevents heat being transferred
from the overheated gas section to the sub-cooled liquid section which is a
more efficient way to use the heat exchanger.
Standard heat exchanger
I-demand function
Limit maximum power consumption. The newly introduced current sensor
minimizes the difference between the actual power consumption and the
predefined power consumption.
Power consumption
e-Pass heat exchanger
Predefined limit
In 85 °C
In 85 °C
43 °C
55 °C
27 °C
72
55 °C
27 °C
60 °C
50 °C
55 °C
Out 45 °C
Out 45 °C
Residential, Commercial and Industrial
Time
VRV S-series – RXYSQ-T
VRV IV Condensing Unit – High Capacity Mini VRV
EER
COP
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure (Nom)
Sound Power (Nom)
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height x Width x Depth
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
RXYSQ8TY1
RXYSQ10TY1
RXYSQ12TY1
22.4
22.4
3.66
4.31
1430x940x320
144
2.333
28
28
3.4
4.24
33.5
33.5
3.3
4.09
1615x940x460
175
180
3.033
3 / 50 / 380~415
10.7
4
9.6
13.4
25
32
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/8 (9.5)
3/4 (19)
100 - 260
17
R410A
55
74
300
3/8 (9.5)
7/8 (22.2)
125 - 325
21
1/2 (12.7)
1 1/8 (28.6)
150 - 390
26
Trade Condensing Unit Price
£4,542.00
£4,963.00
£6,077.00
Maximum Length
Liquid
Gas
dBA
dBA
m
inch (mm)
inch (mm)
55
73
VRV
Outdoor Units
Capacity
57
76
Features:
>High capacity up to 33.5kW nominal cooling
>Horizontal blow casing
>Variable Refrigerant Temperature
>Connection to stylish split fan coils
>Compact installation – reduction in floor space
>Available in 8, 10 & 12 hp
Planning requirements in built up
areas require increasingly more
innovative products to overcome
restrictions, especially on visibility
of plant.
By having a smaller footprint and weight than its big brother,
the extended high capacity Mini VRV range is easier to hide and
can help to maximise the lettable floor area on a design.
Mini VRV systems deliver VRV performance in a small, convenient
package by offering a compact, horizontal blow, air conditioning
solution for projects with lower capacity requirements or
where discretion is required due to the planning or aesthetic
requirements of the application.
Daikin are pleased to announce that Mini VRV systems have
received a complete redesign, and with this extension to the
range which includes new features to increase performance,
convenience and flexibility, Mini VRV from Daikin will become an
even more popular choice for residential and smaller capacity
Air conditioning applications.
10/12 hp
8 hp
Price List 2016
73
VRV IV i-series – SB.RKXYQ-T
VRV IV Condensing Unit – For Indoor Installation
VRV
The VRV IV i-series is a truly unique solution for installations where you want a completely invisible
solution. The system is installed entirely indoors and only the grilles are visible. So it’s ideal for
urban environments, where space and planning restrictions are especially challenging.
A cost effective solution
Even when it is possible to install an outdoor unit, there are
reasons that an indoor installation offers a better solution,
such as in areas where there is a mixture of commercial and
residential use.
With the VRV IV i-series, the units are effectively invisible
because they are installed indoors. Thanks to their low operating
sound, they are highly suited to densely populated areas such
as city centres – and dedicated modes reduce sound further to
comply with inner-city noise regulations, so there is no need for
costly sound insulation.
The VRV IV i-series offers:
> A unique VRV indoor solution: the ‘outdoor’ air conditioning
unit can now be fitted indoors
> Connection with up to 10 indoor units
> Seamless integration into surrounding architecture
> Total flexibility for any shop location and building type
> Easy compliance with planning regulations, the best solution
for urban locations
> A total solution when combined with ventilation
units and Biddle air curtains
Nor is there ay need to use a crane for installation on the
roof or back of the property as the unit comes in two parts,
making the VRV IV i-series easier and more cost effective to
install.
RDXYQ-T
RKXYQ-T
i
Total Piping length possibilities RKXYQ5
(a) =HM <> CM
(b) = CM <> IU
(c) = (a) + (b)
5
10
15
20
25
30
135
125
115
105
95
85
140
135
130
125
120
115
HM: Heat Exchanger Module
CM: Compressor Module
74
Residential, Commercial and Industrial
VRV IV i-series – SB.RKXYQ-T
VRV IV Condensing Unit – for indoor installation
Unique split unit for
indoor installation
Superior efficiencies
> P
atented V-shape heat exchanger for the most compact unit
(400 mm high)
> S uper-efficient centrifugal fans (85% more efficient than
equivalent sirocco fan)
> Inverter fan can be easily adjusted to the length of ductwork
> O
ptimised shape for higher air flow and static pressure, resulting
in much higher efficiencies when compared to standard outdoor
units installed indoors
Installation flexibility
> U
nrivalled flexibility because the unit is split into two elements:
the heat exchanger and the compressor
Compact compressor unit
> L ightweight units reduce installation time and effort, making it
easy for just two people to transport and install
> Small footprint maximizing usable floor space (600 x 554 mm)
> S horter pipe runs between the indoor units reduces
installation costs
> Can easily be mounted in a storage room or back office
> Rotating switchbox for easy maintenance
> Easy serviceability, all components can be easily reached
System
SB.RKXYQ
Capacity range
Cooling capacity / Heating capacity
EER / COP
Maximum number of connectable indoor units
Indoor index connection
Min. / Nom. / Max.
Operation range - outdoor air temperature
Cooling
Heating
Refrigerant
Type / GWP
Piping connections between
Liquid
compressor module (CM) and
Gas
heat exchanger module (HM)
Maximum length
Max height difference - CM below HM
Max height difference - CM above HM
Piping connections between
Liquid
compressor module (CM) and
Gas
indoor units (IU)
Max total piping length (incl. piping to HM)
Max length to last IU
Max height difference - CM below IU
Max height difference - CM above IU
Max height difference - IU - IU
HP
kW
Nom.
Min.~Max.
Min.~Max.
OD
OD
OD
OD
°CDB
°CWB
kg / TCO2
inch (mm)
inch (mm)
m
m
m
inch (mm)
inch (mm)
m
m
m
m
m
Trade Condensing Unit Price
Sound pressure level
Drain pipe
Power supply
RDXYQ
Height x Width x Depth
Min~Max
Suction size
Discharge size
Max ESP
Nom. air flow
OD
Phase / Frequence / Voltage
mm
kg
°CDB
mm
mm
Pa
m³/s
dBa
mm
Trade Condensing Unit Price
Trade Condensing Unit Price
5T
397 x 1456 x 1044
97
5 ~ 35
1196 x 298
1196 x 298
150
0.917
47
32 (VP25)
1~ / 50 Hz / 220-240V
£1,966.00
Compressor module
Dimensions
Weight
Refrigerant charge
Ambient installation conditions
Sound pressure level
Power supply
5T
5
14 / 14
3.2 / 3.8
10
62.5 / 125 / 162.5
-5 ~ 46
-20 ~ 15.5
R-410A / 2087.5
1/2 (12.7)
3/4 (19)
30
10
10
3/8 (9.5)
5/8 (15.9)
140
70 (90 equivalent)
30
30
15
£4,572.00
Heat exchanger module
Dimensions
Weight
Ambient installation temperatures
Ducting
VRV
Compact and easy to hide, the compressor can be installed
at floor level, in a back office, storage room, technical area
or in a kitchen, while the heat exchanger can be installed in
a false ceiling space. This means that the air conditioning
system is completely invisible and does not take up expensive
commercial floor space.
> V
ariable Refrigerant Temperature for best seasonal
efficiency & comfort
RKXYQ
Heigth x Width x Depth
Min~Max
Phase / Frequence / Voltage
mm
kg
kg
°CDB
dBa
5T
701 x 600 x 554
77
2,0
5 ~ 35
47
3~ / 50 Hz / 380-415V
£2,606.00
Price List 2016
75
RYYQ-T
Replaces RXYQ-P9 / RXYHQ-P9 / RXYRQ-P9 / RXHQ-P
Heat Pump VRV IV
VRV
3 revolutionary features:
Variable Refrigerant Temperature
Customise your VRV for best Seasonal Efficiency and comfort:
> R
evolutionary variable refrigerant temperature control
automatically adapts the system to individual building and
climate requirements for greater efficiency and comfort
> C
ontinuously adjusts refrigerant temperature to the actual
temperature and capacity required
> D
efault mode optimised by Daikin for UK conditions with
maximum efficiency and comfort
> Delivers annual cost savings of up to 28%
VRV configurator
Continuous heating during defrost
Advanced software for simplified commissioning,
servicing, configuration and customisation:
The new standard in heating comfort:
> Simplified commissioning: graphical interface to configure,
commission and upload system settings
> U
nique continuous heating technology makes VRV IV Heat Pump
the best alternative to traditional heating systems
> Delivers uninterrupted heat, even during the defrost cycle
> Simplified servicing: additional 7-segment indicator for easy
and quick access to basic functions and error read out
> Maintains comfortable indoor climate at all times
> Manage systems over multiple sites
RYYQ-T (up to 20 hp)
VRV IV Heat Pump with Continuous Heating
Outdoor Units
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height x Width x Depth
mm
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
RYYQ8T
RYYQ10T
RYYQ12T
RYYQ14T
RYYQ16T
RYYQ18T
RYYQ20T
22.40
25.00
4.30
7.53*
4.54
1685 x 930
x 765
261
2.700
78
28.00
31.50
3.84
7.2*
4.27
1685 x 930
x 765
268
2.917
78
33.50
37.50
3.73
6.96*
4.12
1685 x 930
x 765
268
3.083
78
45.00
50.00
3.46
6.5*
3.91
1685 x 1240
x 765
364
4.333
78
50.00
56.00
3.40
6.38*
3.89
1685 x 1240
x 765
398
4.183
78
56.00
63.00
3.03
5.67*
3.71
1685 x 1240
x 765
398
4.350
78
8.4
11.5
14.2
20.6
23.4
29.5
20
25
32
40
40
50
5.9
6.0
6.3
10.4
11.7
11.8
58
78
165
58
79
165
61
81
165
64
86
165
65
86
165
66
88
165
3/8 (9.5)
3/4 (19)
100~260
64
3/8 (9.5)
7/8 (22.2)
125~325
64
1/2 (12.7)
1 1/8 (28.6)
150~390
64
40.00
45.00
3.64
6.83*
4.02
1685 x 1240
x 765
364
3.717
78
3 / 50 / 380~415
17.2
4
32
R410A
10.3
data book
61
81
165
data book
1/2 (12.7)
1 1/8 (28.6)
175~455
64
1/2 (12.7)
1 1/8 (28.6)
200~520
64
5/8 (15.9)
1 1/8 (28.6)
225~585
64
5/8 (15.9)
1 1/8 (28.6)
250~650
64
£4,542.00
£4,963.00
£6,077.00
£7,090.00
£8,183.00
£9,116.00
£10,028.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
76
Residential, Commercial and Industrial
RYYQ-T (22 to 24 hp)
VRV IV Heat Pump with Continuous Heating
RYYQ22T
RYYQ24T
RYMQ10T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height x Width x Depth
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
RYMQ12T
RYMQ8T
RYMQ16T
61.50
69.00
3.77
7.07*
4.18
67.40
75.00
3.70
6.81*
4.10
1685 x 930 x 765
195
2.917
78
1685 x 930 x 765
1685 x 930 x 765
195
188
3.083
2.700
78
78
3 / 50 / 380~415
14.2
8.4
4
32
20
R410A
6.3
5.9
databook
61
58
81
78
11.5
25
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
6.0
58
79
1685 x 1240 x 765
309
4.333
78
VRV
Outdoor Units
20.6
40
10.4
64
86
165
165
databook
Capacity Index Limit
Maximum Number of Connected Indoor Units
5/8 (15.9)
1 1/8 (28.6)
275~715
64
5/8 (15.9)
1 3/8 (34.9)
300~780
64
Trade Condensing Unit Price
£11,040.00
£12,725.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
RYYQ-T (26 to 34 hp)
VRV IV Heat Pump with Continuous Heating
Outdoor Units
RYYQ26T
RYYQ28T
RYYQ30T
RYYQ32T
RYYQ34T
RYMQ12T RYMQ14T RYMQ12T RYMQ16T RYMQ12T RYMQ18T RYMQ16T RYMQ16T RYMQ16T RYMQ18T
Capacity
EER
ESEER
COP
Dimensions
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
73.50
82.50
3.68
6.89*
4.06
78.50
87.50
3.57
6.69*
4.00
83.50
93.50
3.52
6.6*
3.98
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/4 (19)
1 3/8 (34.9)
325~845
64
3/4 (19)
1 3/8 (34.9)
350~910
64
1685
1685
930
1240
765
765
195
319
3.083
4.183
78
78
3 / 50 / 380~415
14.2
23.4
4
32
40
R410A
6.3
11.7
data book
61
65
81
86
165
data book
3/4 (19)
1 3/8 (34.9)
375~975
64
Trade Condensing Unit Price
£13,167.00
£14,260.00
£15,193.00
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
1685
930
765
195
3.083
78
1685
1240
765
309
3.717
78
1685
930
765
195
3.083
78
1685
1240
765
309
4.333
78
14.2
17.2
14.2
20.6
32
32
32
40
6.3
10.3
6.3
10.4
61
81
61
81
61
81
64
86
90.00
100.00
3.46
6.5*
3.91
95.00
106.00
3.43
6.44*
3.90
1685
1240
765
309
4.333
78
1685
1240
765
309
4.333
78
1685
1240
765
309
4.333
78
1685
1240
765
319
4.183
78
20.6
20.6
20.6
23.4
40
40
40
40
10.4
10.4
10.4
11.7
64
86
64
86
64
86
65
86
3/4 (19)
1 3/8 (34.9)
400~1040
64
3/4 (19)
1 3/8 (34.9)
425~1105
64
£16,366.00
£17,299.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Price List 2016
77
RYYQ-T (36 to 42 hp)
VRV IV Heat Pump with Continuous Heating
Outdoor Units
RYYQ36T
RYYQ38T
RYYQ40T
RYYQ42T
RYMQ16T RYMQ20T RYMQ8T RYMQ10T RYMQ20T RYMQ10T RYMQ12T RYMQ18T RYMQ10T RYMQ16T RYMQ16T
VRV
Capacity
EER
ESEER
COP
Dimensions
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
101.00
113.00
3.21
6.02*
3.79
1685
1685
1240
1240
765
765
309
319
4.333
4.350
78
78
1685
930
765
188
2.700
78
106.00
120.00
3.42
6.36*
4.01
1685
930
765
195
2.917
78
1685
1240
765
319
4.350
78
112.00
125.00
3.61
6.74*
4.05
1685
930
765
195
3.083
78
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/4 (19)
1 5/8 (41.3)
450~1170
64
3/4 (19)
1 5/8 (41.3)
475~1235
64
1685
930
765
195
2.917
78
3 / 50 / 380~415
11.5
14.2
4
25
32
R410A
6.0
6.3
data book
58
61
79
81
165
data book
3/4 (19)
1 5/8 (41.3)
500~1300
64
Trade Condensing Unit Price
£18,211.00
£19,533.00
£20,156.00
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
20.6
29.5
8.4
11.5
29.5
40
50
20
25
50
10.4
11.8
5.9
6.0
11.8
64
86
66
88
58
78
58
79
66
88
1685
1240
765
319
4.183
78
1685
930
765
195
2.917
78
118.00
132.00
3.54
6.65*
4.00
1685
1240
765
309
4.333
78
23.4
11.5
20.6
20.6
40
25
40
40
11.7
6.0
10.4
10.4
65
86
58
79
64
86
64
86
1685
1240
765
309
4.333
78
3/4 (19)
1 5/8 (41.3)
525~1365
64
£21,329.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
RYYQ-T (44 to 48 hp)
VRV IV Heat Pump with Continuous Heating
Outdoor Units
Capacity
RYYQ44T
1685
930
765
195
3.083
78
124.00
138.00
3.54
6.62*
3.98
1685
1240
765
309
4.333
78
1685
1240
765
309
4.333
78
1685
1240
765
309
3.717
78
14.2
20.6
20.6
17.2
32
40
40
32
6.3
10.4
10.4
10.3
61
81
64
86
64
86
61
81
RYMQ16T
Trade Condensing Unit Price
£22,443.00
£23,456.00
Sound Pressure
Sound Power
Piping Limits
Piping Connections
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
RYMQ14T
Capacity Index Limit
Maximum Number of Connected Indoor Units
Refrigerant Circuit
Height
Width
Depth
RYMQ16T
3/4 (19)
1 5/8 (41.3)
550~1430
64
Weight
Air Flow Rate
External Static Pressure
Electrical Details
kW
kW
RYMQ16T
130.00
145.00
3.51
6.6*
3.94
1685
1240
765
309
4.333
78
3 / 50 / 380~415
20.6
4
40
R410A
10.4
data book
64
86
165
data book
3/4 (19)
1 5/8 (41.3)
575~1495
64
EER
ESEER
COP
Dimensions
Nominal Cooling
Nominal Heating
RYYQ46T
RYMQ12T
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
RYYQ48T
RYMQ16T
RYMQ16T
RYMQ16T
RYMQ16T
1685
1240
765
309
4.333
78
1685
1240
765
309
4.333
78
135.00
150.00
3.46
6.5*
3.91
1685
1240
765
309
4.333
78
1685
1240
765
309
4.333
78
20.6
20.6
20.6
20.6
40
40
40
40
10.4
10.4
10.4
10.4
64
86
64
86
64
86
64
86
3/4 (19)
1 5/8 (41.3)
600~1560
64
£24,549.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
78
Residential, Commercial and Industrial
RYYQ-T (50 to 54 hp)
VRV IV Heat Pump with Continuous Heating
Capacity
RYYQ50T
RYYQ52T
RYMQ16T
RYMQ16T
RYMQ18T
RYMQ16T
1685
1240
765
319
4.183
78
1685
1240
765
309
4.333
78
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/4 (19)
1 5/8 (41.3)
625~1625
64
145.00
162.00
3.42
6.42*
3.89
1685
1240
765
319
4.183
78
3 / 50 / 380~415
23.4
4
40
R410A
11.7
data book
65
86
165
data book
3/4 (19)
1 5/8 (41.3)
650~1690
64
Trade Condensing Unit Price
£25,482.00
£26,415.00
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
1685
1240
765
309
4.333
78
140.00
156.00
3.44
6.46*
3.90
1685
1240
765
309
4.333
78
20.6
20.6
23.4
20.6
40
40
40
40
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
10.4
10.4
11.7
10.4
64
86
64
86
65
86
64
86
RYMQ18T
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Gas
RYYQ54T
RYMQ18T
RYMQ18T
RYMQ18T
RYMQ18T
1685
1240
765
319
4.183
78
1685
1240
765
319
4.183
78
150.00
168.00
3.40
6.38*
3.89
1685
1240
765
319
4.183
78
1685
1240
765
319
4.183
78
23.4
23.4
23.4
23.4
40
40
40
40
11.7
11.7
11.7
11.7
65
86
65
86
65
86
65
86
VRV
Outdoor Units
3/4 (19)
1 5/8 (41.3)
675~1755
64
£27,348.00
* The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Price List 2016
79
REYQ-T (8 to 12 hp)
VRV IV Condensing Units – Heat Recovery
Outdoor Units
8 hp Single
10 hp Single
REYQ8T
REYQ10T
22.40
22.40
1685 x 930 x 765
210
2.700
28.00
28.00
1685 x 930 x 765
218
2.917
8.9
11.8
20
25
9.7
9.8
58
78
58
79
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/8 (9.5)
5/8 (15.9)
3/4 (19)
100 ~ 260
64
3/8 (9.5)
3/4 (19)
7/8 (22.2)
125 ~ 325
64
3/8 (9.5)
3/4 (19)
7/8 (22.2)
125 ~ 325
64
1/2 (12.7)
3/4 (19)
1 1/8 (28.6)
150 ~ 390
64
Trade Condensing Unit Price
£4,984.00
£5,475.00
£6,840.00
£6,639.00
VRV
Capacity
Dimensions
Weight
Fan
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Air Flow Rate
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
10 hp Multi
REMQ5T
12 hp Single
REMQ5T
REYQ12T
1685 x 930 x 765
198
2.700
33.50
33.50
1685 x 930 x 765
218
3.084
5.3
15.3
20
25
9.7
9.9
58
78
61
81
28.00
28.00
1685 x 930 x 765
198
2.700
3 / 50 / 380~415
5.3
4
20
R410A
9.7
data book
58
78
1000
165
REYQ-T (13 to 16 hp)
VRV IV Condensing Units – Heat Recovery
Outdoor Units
13 hp Multi
REYQ8T
Capacity
Dimensions
Weight
Fan
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Air Flow Rate
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
80
Residential, Commercial and Industrial
REMQ5T
36.40
33.50
1685 x 930 x 765
1685 x 930 x 765
210
210
2.700
2.700
8.9
5.3
20
20
9.7
9.7
58
78
58
78
1/2 (12.7)
3/4 (19)
1 1/8 (28.6)
162.5 ~ 422.5
64
£8,404.00
14 hp Single
16 hp Single
REYQ14T
REYQ16T
40.00
45.00
40.00
45.00
1685 x 1240 x 765 1685 x 1240 x 765
304
305
3.717
4.334
3 / 50 / 380~415
17.4
21.1
4
32
40
R410A
11.8
11.8
data book
61
64
81
86
1000
165
1/2 (12.7)
1/2 (12.7)
7/8 (22.2)
7/8 (22.2)
1 1/8 (28.6)
1 1/8 (28.6)
175 ~ 455
200 ~ 520
64
64
£7,827.00
£9,224.00
16 hp Multi
REYQ8T
REYQ8T
45.00
45.00
1685 x 930 x 765
1685 x 930 x 765
210
210
2.700
2.700
8.9
8.9
20
20
9.7
9.7
58
78
58
78
1/2 (12.7)
7/8 (22.2)
1 1/8 (28.6)
200 ~ 520
64
£9,968.00
REYQ-T (18 to 20 hp)
VRV IV Condensing Units – Heat Recovery
18 hp Single
18 hp Multi
REYQ18T
Capacity
Dimensions
Weight
Fan
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Air Flow Rate
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
REYQ8T
50.40
50.40
1685 x 1240 x 765
337
4.184
40
11.8
65
86
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
£10,254.00
20 hp Multi
REYQ20T
REYQ10T
51.00
56.00
51.00
56.00
1685 x 930 x 765
1685 x 930 x 765
1685 x 1240 x 765
210
218
337
2.700
2.917
4.350
3 / 50 / 380~415
8.9
11.8
31.1
4
20
25
50
R410A
9.7
9.8
11.8
data book
58
58
66
78
79
88
1000
165
5/8 (15.9)
5/8 (15.9)
7/8 (22.2)
1 1/8 (28.6)
1 1/8 (28.6)
1 1/8 (28.6)
225 ~ 585
250 ~ 650
64
64
24.6
5/8 (15.9)
7/8 (22.2)
1 1/8 (28.6)
225 ~ 585
64
20 hp Single
REYQ10T
£10,459.00
REYQ10T
56.00
56.00
1685 x 930 x 765
1685 x 930 x 765
218
218
2.917
2.917
11.8
11.8
25
25
9.8
9.8
58
79
58
79
£11,395.00
VRV
Outdoor Units
5/8 (15.9)
1 1/8 (28.6)
1 1/8 (28.6)
250 ~ 650
64
£10,950.00
REYQ-T (22 to 28 hp)
VRV IV Condensing Units – Heat Recovery
Outdoor Units
22 hp Multi
REYQ10T
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
24 hp Multi
REYQ12T
61.50
61.50
1685 x 930
1685 x 930
x 765
x 765
218
218
2.917
3.084
11.8
15.3
25
25
9.8
9.9
58
79
61
81
Capacity Index Limit
Maximum Number of Connected Indoor Units
5/8 (15.9)
1 1/8 (28.6)
1 1/8 (28.6)
275 ~ 715
64
Trade Condensing Unit Price
£12,114.00
REYQ8T
REYQ16T
26 hp Multi
REYQ12T
REYQ14T
67.40
73.50
67.40
73.50
1685 x 930
1685 x 1240
1685 x 930
1685 x 1240
x 765
x 765
x 765
x 765
210
305
218
304
2.700
4.334
3.084
3.717
3 / 50 / 380~415
8
21.1
15.3
17.4
4
20
40
25
32
R410A
9.7
11.8
9.9
11.8
data book
58
64
61
61
78
86
81
81
1000
165
5/8 (15.9)
3/4 (19)
1 1/8 (28.6)
1 1/8 (28.6)
1 3/8 (34.9)
1 3/8 (34.9)
300 ~ 780
325 ~ 845
64
64
£14,208.00
£14,466.00
28 hp Multi
REYQ12T
REYQ16T
78.50
78.50
1685 x 930
1685 x 1240
x 765
x 765
218
305
3.084
4.334
15.3
21.1
25
40
9.9
11.8
61
81
64
86
3/4 (19)
1 1/8 (28.6)
1 3/8 (34.9)
350 ~ 910
64
£15,863.00
Price List 2016
81
REYQ-T (44 to 48 hp)
VRV IV Condensing Units – Heat Recovery
Outdoor Units
44 hp Multi
REYQ12T
Capacity
VRV
REYQ14T
218
3.084
1685 x
1240 x
765
305
4.334
1685 x
1240 x
765
319
3.717
15.3
21.1
21.1
17.4
25
40
40
32
9.9
11.8
11.8
64
86
61
81
Capacity Index Limit
Maximum Number of Connected Indoor Units
11.8
data book
64
86
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
550 ~ 1430
64
Trade Condensing Unit Price
£25,087.00
Weight
Fan
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
Air Flow Rate
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
46 hp Multi
REYQ16T
123.50
123.50
1685 x
1240 x
765
305
4.334
Dimensions
Nominal Cooling
Nominal Heating
Height x Width x Depth
REYQ16T
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
1685 x 930
x 765
61
81
REYQ16T
130.00
130.00
1685 x
1240 x
765
305
4.334
3 / 50 / 380~415
21.1
4
40
R410A
11.8
data book
64
86
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
575 ~ 1495
64
48 hp Multi
REYQ16T
REYQ16T
REYQ16T
REYQ16T
1685 x
1240 x
765
305
4.334
1685 x
1240 x
765
305
4.334
135.00
135.00
1685 x
1240 x
765
305
4.334
1685 x
1240 x
765
305
4.334
21.1
21.1
21.1
21.1
40
40
40
40
11.8
11.8
11.8
64
86
64
86
11.8
data book
64
86
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
600 ~ 1560
64
£26,275.00
64
86
£27,672.00
REYQ-T (50 to 54 hp)
VRV IV Condensing Units – Heat Recovery
Outdoor Units
50 hp Multi
52 hp Multi
REYQ16T
REYQ16T
1685 x
1240 x
765
305
4.334
140.40
140.40
1685 x
1240 x
765
305
4.334
1685 x
1240 x
765
337
4.184
1685 x
1240 x
765
305
4.334
21.1
21.1
24.6
21.1
40
40
40
40
11.8
11.8
11.8
65
86
64
86
Capacity Index Limit
Maximum Number of Connected Indoor Units
11.8
data book
64
86
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
625 ~ 1625
64
Trade Condensing Unit Price
£28,702.00
Capacity
Dimensions
Weight
Fan
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
82
Nominal Cooling
Nominal Heating
Height x Width x Depth
Air Flow Rate
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
Residential, Commercial and Industrial
64
86
REYQ18T
REYQ16T
REYQ18T
145.80
145.80
1685 x
1240 x
765
337
4.184
3 / 50 / 380~415
24.6
4
40
R410A
11.8
data book
65
86
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
650 ~ 1690
64
£29,732.00
54 hp Multi
REYQ18T
REYQ18T
REYQ18T
REYQ18T
1685 x
1240 x
765
337
4.184
1685 x
1240 x
765
337
4.184
151.20
151.20
1685 x
1240 x
765
337
4.184
1685 x
1240 x
765
337
4.184
24.6
24.6
24.6
24.6
40
40
40
40
11.8
11.8
11.8
65
86
65
86
11.8
data book
65
86
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
675 ~ 1755
64
£30,762.00
65
86
REYQ-T (30 to 36 hp)
VRV IV Condensing Units – Heat Recovery
30 hp Multi
REYQ12T
Capacity
Dimensions
Weight
Fan
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Air Flow Rate
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
32 hp Multi
REYQ18T
83.90
83.90
1685 x 930
1685 x 1240
x 765
x 765
218
337
3.084
4.184
15.3
24.6
25
40
9.9
11.8
61
81
65
86
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/4 (19)
1 1/8 (28.6)
1 3/8 (34.9)
375 ~ 975
64
Trade Condensing Unit Price
£16,893.00
REYQ16T
34 hp Multi
REYQ16T
REYQ16T
36 hp Multi
REYQ18T
REYQ16T
90.00
95.40
90.00
95.40
1685 x 1240
1685 x 1240
1685 x 1240
1685 x 1240
x 765
x 765
x 765
x 765
305
305
305
337
4.334
4.334
4.334
4.184
3 / 50 / 380~415
21.1
21.1
21.1
24.6
4
40
40
40
40
R410A
11.8
11.8
11.8
11.8
data book
64
64
64
65
86
86
86
86
1000
165
3/4 (19)
3/4 (19)
1 1/8 (28.6)
1 1/8 (28.6)
1 3/8 (34.9)
1 3/8 (34.9)
400 ~ 1040
425 ~ 1105
64
64
£18,448.00
REYQ20T
101.00
101.00
1685 x 1240
1685 x 1240
x 765
x 765
305
337
4.334
4.350
21.1
31.1
40
50
11.8
11.8
64
86
66
88
3/4 (19)
1 1/8 (28.6)
1 5/8 (41.3)
450 ~ 1170
64
£19,478.00
£20,619.00
REYQ-T (38 to 42 hp)
VRV IV Condensing Units – Heat Recovery
Outdoor Units
38 hp Multi
REYQ12T
1685 x 930
x 765
218
3.084
1685 x
1240 x
765
337
4.184
111.90
111.90
1685 x 930
x 765
8.9
15.3
24.6
11.8
20
25
40
25
9.7
11.8
9.8
65
86
58
79
Capacity Index Limit
Maximum Number of Connected Indoor Units
9.9
data book
61
81
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
475 ~ 1235
64
Trade Condensing Unit Price
£21,877.00
Dimensions
Weight
Fan
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections Systems
Nominal Cooling
Nominal Heating
Height x Width x Depth
Air Flow Rate
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Total Length
Maximum Actual Length
Liquid
Discharge
Gas
kW
kW
mm
kg
m3/sec
Phase / Hz / V
amps
amps
amps
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
REYQ12T
1685 x 930
x 765
106.30
106.30
1685 x 930
x 765
210
2.700
40 hp Multi
REYQ10T
Capacity
REYQ8T
58
78
REYQ18T
218
2.917
218
3.084
3 / 50 / 380~415
15.3
4
25
R410A
9.9
data book
61
81
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
500 ~ 1300
64
£22,368.00
42 hp Multi
REYQ18T
REYQ10T
REYQ16T
REYQ16T
1685 x
1240 x
765
305
4.334
1685 x
1240 x
765
337
4.184
1685 x 930
x 765
218
2.917
118.00
118.00
1685 x
1240 x
765
305
4.334
24.6
11.8
21.1
21.1
40
25
40
40
11.8
9.8
11.8
65
86
58
79
11.8
data book
64
86
1000
165
3/4 (19)
1 3/8 (34.9)
1 5/8 (41.3)
525 ~ 1365
64
64
86
£23,923.00
Price List 2016
83
VRV
Outdoor Units
RXYQQ-T / RQEQ-P3
Replacement VRV-Q
VRV
Optimise your business
Tackle more projects in less time:
New
Lower installation costs:
Now it's possible to connect VRV IV BS
boxes, including the small, light Multi
BS boxes designed to offer the largest &
most flexible range of design & installation
options available.
Due to faster installation. VRV-Q is more cost-effective than replacing the
full system with new piping.
Offer customers the overall lowest cost solution and improve your
competitive edge.
Easy as one-two-three:
A simple solution: Daikin VRV-Q enables you to handle more projects for
more customers in less time and offer them the best price! Everybody wins.
Compare installation steps
Conventional solution
1 Recover refrigerant
2 Remove units
3 Remove refrigerant pipes
VRV-Q
1 Recover refrigerant
2 Remove units
Re-use existing piping
and wiring
5 Install new units
3 Install new units
6 Leak test
4 Leak test
7 Vacuum drying
5 Vacuum drying
9 Collect contamination
10Test operation
4
6
Automatic refrigerant
charging, cleaning
and testing
Reuse drain pipes
Durable PVC pipes can be easily reused. Only flow tests are required.
4
4 Install new piping/wiring
8 Refrigerant charging
The Daikin low-cost
upgrade solution
Reuse refrigerant pipes
Pipes used for R-22 will also work with VRV-Q, thanks to lower
operating pressures of the system.
4
Reuse refrigerant branch pipes
There are no restrictions when upgrading from a Daikin VRV system.
Other VRF systems require branch pipes to withstand pressure up
to 3.3 MPa.
!
Replace indoor units and BS boxes
Contact your local dealer to check compatibility in case you need
to keep the indoor units.
4
Reuse remote control wiring
Reuse wiring when upgrading from a Daikin VRV system. In other cases,
this will depend on the cable type.
Up to 45% shorter
installation time
Customer benefits
4
Reuse indoor-outdoor wiring
Restrictions: see remote control wiring.
!
Replace outdoor units
Always operational
Avoid loss of business
Replacing now prevents unplanned, lengthy disruption of air
conditioning systems. It also avoids loss of business for shops,
complaints from guests in hotels, lower working efficiency and loss
of tenants in offices.
Reduced energy consumption
Up to 40% energy saving
Quick and easy installation
No interruption of daily business while replacing the system thanks
to phased-in, fast installation.
Comparison of
10hp systems:
Lower long-term costs
Repairing systems with R-22 has been prohibited since 31 December 2014.
Installing a technically advanced Replacement VRV-Q system reduces
energy consumption and maintenance costs from day one.
84
Residential, Commercial and Industrial
Cooling mode
Heating mode
R-22 (RSXY-KA7)
R-407C (RSXYP-L7) R-410A (RXYQQ-T)
Key Guidelines for a Quality Replacement with VRV-Q
VRV
R22 is a hydrochlorofluorocarbon (HCFC) which was commonly used in air conditioning systems.
However, both new and recycled sources of R22 are now banned.
Many systems today are still running on R22. But as R22 is no longer available, now’s the time to
replace R22 systems. The good news is that Daikin’s VRV-Q solution delivers significantly higher energy
efficiencies, with the potential of saving up to 50%, compared with installing a completely new system.
The Daikin low-cost upgrade solution
4
Reuse drain pipes
Durable PVC pipes can be easily reused. Only flow tests are required.
4
Reuse refrigerant pipes
Pipes used for R-22 will also work with VRV-Q, thanks to lower
operating pressures of the system.
4
Reuse refrigerant branch pipes
There are no restrictions when upgrading from a Daikin VRV system.
Other VRF systems require branch pipes to withstand pressure up
to 3.3 MPa.
!
Replace indoor units and BS boxes
Contact your local dealer to check compatibility in case you need
to keep the indoor units.
4
Reuse remote control wiring
Reuse wiring when upgrading from a Daikin VRV system. In other cases,
this will depend on the cable type.
4
Reuse indoor-outdoor wiring
Restrictions: see remote control wiring.
!
Replace outdoor units
Refrigerant branch pipes
Refrigerant oil
Refrigerant branch pipes, including those from other
manufacturers, Y-refnets, T-refnets and headers, can be reused
under the following conditions:
Refrigerant piping can be reused if one of the following oils was
used: Barrel Freeze, Ethereal, Ester, Ferreol, HAB, MS, Suniso.
✓ Pipes are corrosion-free
✓ Pipes are insulated
✓ Pipes can withstand a pressure up to 3.3 MPa
✓ There are no special components that implement
decompression (e.g. oil trap)
✓ Installed copper pipework is in suitable condition (piping
thickness will generally meet specifications, since the unique
Daikin VRV solution operates at lower pressure levels)
Maximum piping lengths and level distances
VRV-Q can be installed for piping systems with a total length up
to 300m. See data book for further guidelines.
Price List 2016
85
RXYQQ-T (up to 20 hp)
VRV IV-Q Condensing Unit – Heat Pump
Outdoor Units
Capacity
VRV
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
RXYQQ8T
RXYQQ10T
RXYQQ12T
RXYQQ14T
RXYQQ16T
RXYQQ18T
RXYQQ20T
22.40
25.00
4.30
7.53*
4.54
1685
930
765
187
2.700
28.00
31.50
3.84
7.20*
4.27
1685
930
765
194
2.917
33.50
37.50
3.73
6.96*
4.12
1685
930
765
194
3.083
45.00
50.00
3.46
6.50*
3.91
1685
1240
765
305
3.883
50.00
56.00
3.40
6.38*
3.89
1685
1240
765
314
4.183
56.00
63.00
3.03
5.67*
3.71
1685
1240
765
314
4.350
8.4
11.5
14.2
20.6
23.4
29.5
20
25
32
40
40
50
5.9
6.0
6.3
10.4
11.7
11.8
58
78
58
79
61
81
64
86
65
86
66
88
3/8 (9.5)
3/4 (19)
100~260
64
3/8 (9.5)
7/8 (22.2)
125~325
64
1/2 (12.7)
1 1/8 (28.6)
150~390
64
40.00
45.00
3.64
6.83*
4.02
1685
1240
765
306
3.717
78
3 / 50 / 380~415
17.2
4
32
R410A
10.3
data book
61
81
120
50
1/2 (12.7)
1 1/8 (28.6)
175~455
64
1/2 (12.7)
1 1/8 (28.6)
200~520
64
5/8 (15.9)
1 1/8 (28.6)
225~585
64
5/8 (15.9)
1 1/8 (28.6)
250~650
64
£5,077.00
£5,548.00
£6,435.00
£7,508.00
£8,665.00
£10,165.00
£11,161.00
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
RXYQQ-T (22 to 28 hp)
VRV IV-Q Condensing Unit – Heat Pump
Outdoor Units
RXYQQ22T
RXYQQ10T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
RXYQQ24T
RXYQQ12T
RXYQQ8T
61.50
69.00
3.78
7.07*
4.19
1685
930
765
194
2.917
RXYQQ16T
RXYQQ26T
RXYQQ12T
67.40
75.00
3.70
6.81*
4.10
1685
930
765
194
3.083
1685
930
765
187
2.100
11.5
14.2
8.4
25
32
20
6.0
6.3
5.29
58
79
61
81
58
78
RXYQQ28T
RXYQQ14T
RXYQQ12T
73.50
82.50
3.68
6.89*
4.06
1685
1240
765
305
3.883
1685
930
765
194
3.083
RXYQQ16T
78.50
87.50
3.57
6.69*
4.00
1685
1240
765
306
3.717
1685
930
765
194
3.083
1685
1240
765
305
3.883
17.2
14.2
20.6
32
32
40
10.3
6.3
10.4
61
81
61
81
64
86
78
3 / 50 / 380~415
20.6
14.2
4
40
32
R410A
10.4
6.3
data book
64
61
86
81
120
50
Capacity Index Limit
Maximum Number of Connected Indoor Units
5/8 (15.9)
1 1/8 (28.6)
275~715
64
5/8 (15.9)
1 3/8 (34.9)
300~780
64
3/4 (19)
1 3/8 (34.9)
325~845
64
3/4 (19)
1 3/8 (34.9)
350~910
64
Trade Condensing Unit Price
£11,983.00
£13,742.00
£13,943.00
£15,100.00
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
86
Residential, Commercial and Industrial
RXYQQ-T (30 to 36 hp)
VRV IV-Q Condensing Unit – Heat Pump
RXYQQ30T
RXYQQ12T
Capacity
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
RXYQQ32T
RXYQQ18T
RXYQQ16T
83.50
93.50
3.53
6.60*
3.98
1685
930
765
194
3.083
RXYQQ34T
RXYQQ16T
RXYQQ16T
90.00
100.00
3.50
6.50*
3.90
1685
1240
765
314
4.183
1685
1240
765
305
3.883
14.2
23.4
20.6
32
40
40
6.3
11.7
10.4
61
81
65
86
64
86
RXYQQ36T
RXYQQ18T
RXYQQ16T
95.00
106.00
3.40
6.44*
3.90
1685
1240
765
305
3.883
1685
1240
765
305
3.883
RXYQQ20T
101.00
113.00
3.20
6.02*
3.80
1685
1240
765
314
4.183
1685
1240
765
305
3.883
1685
1240
765
314
4.350
23.4
20.6
29.5
40
40
50
11.7
10.4
11.8
65
86
64
86
66
88
78
3 / 50 / 380~415
20.6
20.6
4
40
40
R410A
10.4
10.4
data book
64
64
86
86
120
50
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/4 (19)
1 3/8 (34.9)
375~975
64
3/4 (19)
1 3/8 (34.9)
400~1040
64
3/4 (19)
1 3/8 (34.9)
425~1105
64
3/4 (19)
1 5/8 (41.3)
450~1170
64
Trade Condensing Unit Price
£16,600.00
£17,330.00
£18,830.00
£19,826.00
VRV
Outdoor Units
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
RXYQQ-T (38 to 42 hp)
VRV IV-Q Condensing Unit – Heat Pump
Outdoor Units
RXYQQ38T
RXYQQ8T
Capacity
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/4 (19)
1 5/8 (41.3)
475~1235
64
111.50
125.00
3.61
6.74*
4.05
1685
930
765
194
3.083
78
3 / 50 / 380~415
14.2
4
32
R410A
6.3
data book
61
81
120
50
3/4 (19)
1 5/8 (41.3)
500~1300
64
Trade Condensing Unit Price
£21,786.00
£22,148.00
EER
ESEER
COP
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Sound Power
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
m3/sec
Pa
Phase / Hz / V
amps
amps
amps
RXYQQ40T
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
kg
kg
dBA
dBA
m
m
inch (mm)
inch (mm)
RXYQQ42T
RXYQQ10T RXYQQ20T RXYQQ10T RXYQQ12T RXYQQ18T RXYQQ10T RXYQQ16T
1685
930
765
187
2.100
106.40
119.50
3.43
6.36*
4.00
1685
930
765
194
2.917
1685
1240
765
314
4.350
1685
930
765
194
2.917
8.4
11.5
29.5
11.5
20
25
50
25
5.9
6.0
11.8
6.0
58
78
58
79
66
88
58
79
RXYQQ16T
1685
1240
765
314
4.183
1685
930
765
194
2.917
118.00
131.50
3.54
6.65*
3.99
1685
1240
765
305
3.883
23.4
11.5
20.6
20.6
40
25
40
40
11.7
6.0
10.4
10.4
65
86
58
79
64
86
64
86
1685
1240
765
305
3.883
3/4 (19)
1 5/8 (41.3)
525~1365
64
£22,878.00
*The AUTOMATIC ESEER value corresponds with normal VRV IV Heat Pump operation, taking into account advanced energy saving operation functionality (variant refrigerant temperature control operation).
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
Price List 2016
87
RQCEQ-P3 (28.0 to 45.0 kW)
VRV III-Q Condensing Unit – Heat Recovery
Outdoor Units
RQCEQ280P3
RQEQ140P3
Capacity
VRV
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Nominal Cooling
Nominal Heating
Height
Width
Depth
High
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
kW
kW
mm
mm
mm
kg
m3/sec
Pa
Phase
Hz
V
amps
amps
amps
kg
kg
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
RQCEQ360P3
RQEQ140P3
RQEQ180P3
28.00
32.00
1680
635
765
175
1.583
RQCEQ460P3
RQEQ180P3
RQEQ140P3
RQEQ140P3
36.00
40.00
1680
635
765
175
1.583
1680
635
765
175
1.833
78
1680
635
765
175
1.833
1680
635
765
175
1.583
3ph
50
380~415
8.0
5.5
78
5.5
5.5
8.0
4
15
20
10.3
10.3
10.6
54
58
54
20
R410A
10.6
data book
58
1680
635
765
175
1.833
8.0
15
5.5
4
15
10.3
10.3
10.6
54
54
120
58
4
15
20
120
120
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/8 (9.5)
7/8 (22.2)
3/4 (19)
140~364
21
1/2 (12.7)
1 (25)
3/4 (19)
180~468
28
1/2 (12.7)
1 1/8 (28.6)
7/8 (22.2)
230~598
34
Trade Condensing Unit Price
£6,570.00
£8,450.00
£10,795.00
Piping Connections
RQEQ180P3
45.00
52.00
1680
635
765
175
1.583
78
50
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
RQCEQ-P3 (50.0 to 63.6 kW)
VRV III-Q Condensing Unit – Heat Recovery
Outdoor Units
RQCEQ500P3
RQCEQ540P3
RQCEQ636P3
RQEQ140P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ180P3 RQEQ212P3 RQEQ212P3 RQEQ212P3
Capacity
Capacity Index Limit
Maximum Number of Connected Indoor Units
5/8 (15.9)
1 1/8 (28.6)
7/8 (22.2)
250~650
39
54.00
60.00
1680
635
765
175
1.833
3ph
50
380~415
8.0
4
20
R410A
10.6
data book
58
120
50
5/8 (15.9)
1 1/8 (28.6)
7/8 (22.2)
270~702
43
Trade Condensing Unit Price
£11,735.00
£12,675.00
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
kg
kg
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
1680
635
765
175
1.583
50.00
56.00
1680
635
765
175
1.833
1680
635
765
175
1.833
1680
635
765
175
1.833
8.0
8.0
15
8.0
4
20
20
20
10.3
10.6
10.6
10.6
54
58
58
58
5.5
1680
635
765
175
1.833
1680
635
765
179
1.833
8.0
11.5
20
63.60
67.20
1680
635
765
179
1.833
1680
635
765
179
1.833
11.5
20
11.5
4
20
10.6
11.2
11.2
11.2
58
60
60
60
20
5/8 (15.9)
1 1/8 (28.6)
1 (25)
318~827
47
£14,937.00
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
88
Residential, Commercial and Industrial
RQCEQ-P3 (71.2 to 74.4 kW)
VRV III-Q Condensing Unit – Heat Recovery
RQCEQ712P3
RQEQ140P3
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
RQEQ180P3
RQEQ180P3
RQCEQ744P3
RQEQ212P3
RQEQ140P3
RQEQ180P3
71.20
78.40
1680
635
765
175
1.583
1680
635
765
175
1.833
RQEQ212P3
RQEQ212P3
74.40
80.80
1680
635
765
175
1.833
1680
635
765
179
1.833
1680
635
765
175
1.833
1680
635
765
175
1.833
5.5
8.0
1680
635
765
179
1.833
1680
635
765
179
1.833
11.5
11.5
VRV
Outdoor Units
3ph
50
350~415
5.5
8.0
8.0
11.5
4
15
4
20
20
20
15
20
20
20
10.3
10.6
11.2
11.2
54
58
60
60
R410A
kg
kg
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
10.3
10.6
10.6
11.2
data book
54
58
58
60
120
50
Capacity Index Limit
Maximum Number of Connected Indoor Units
5/8 (15.9)
1 1/8 (28.6)
1 (25)
356~926
52
3/4 (19)
1 3/8 (34.9)
1 (25)
372~967
56
Trade Condensing Unit Price
£16,714.00
£17,468.00
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
RQCEQ-P3 (81.6 to 84.8 kW)
VRV III-Q Condensing Unit – Heat Recovery
Outdoor Units
RQCEQ816P3
RQEQ180P3
Capacity
Dimensions
Weight
Air Flow Rate
Electrical Details
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Cooling
Nominal Heating
Height
Width
Depth
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
Nom
Maximum Length
Maximum Vertical Rise
Liquid
Gas
Discharge
kW
kW
mm
mm
mm
kg
m3/sec
Phase
Hz
V
amps
amps
amps
RQEQ212P3
RQEQ212P3
RQCEQ848P3
RQEQ212P3
RQEQ212P3
RQEQ212P3
81.60
87.20
1680
635
765
175
1.833
1680
635
765
179
1.833
RQEQ212P3
RQEQ212P3
84.80
89.60
1680
635
765
179
1.833
1680
635
765
179
1.833
1680
635
765
179
1.833
1680
635
765
179
1.833
11.5
11.5
1680
635
765
179
1.833
1680
635
765
179
1.833
11.5
11.5
3ph
50
380~415
8.0
11.5
11.5
11.5
4
20
4
20
20
20
20
20
20
20
11.2
11.2
11.2
11.2
60
60
60
60
R410A
kg
kg
dBA
m
m
inch (mm)
inch (mm)
inch (mm)
10.6
11.2
11.2
11.2
data book
58
60
60
60
120
50
Capacity Index Limit
Maximum Number of Connected Indoor Units
3/4 (19)
1 3/8 (34.9)
1 1/8 (28.6)
408~1061
60
3/4 (19)
1 3/8 (34.9)
1 1/8 (28.6)
424~1102
64
Trade Condensing Unit Price
£19,162.00
£19,916.00
Please see note on page 91 regarding VRV III-Q warranty, and contact your local sales office for more information on VRV III-Q installation.
Price List 2016
89
Y
E N E R G P TO
GS U
SAVIN
Daikin Network Service System (DNSS)
Remote Monitoring and Lifecycle Management
25%
VRV
DNSS is a remote monitoring system, which will allow you to
continuously optimise the running of your Daikin equipment; control
your energy consumption (so reduce your Carbon Footprint), extend
the life span of your equipment and reduce operational costs.
Prevent product malfunctions
The DNSS will analyse the data from your equipment every minute
of the day and will alert us before the equipment actually breaks
down. In this way, failures can be prevented and possible down
time reduced to an absolute minimum.
Remote diagnostics
The DNSS continuously checks the cleanliness of the system filters
and heat exchanger. Furthermore, the DNSS manages a wide range
of data (pressures, temperatures, running hours, etc.) in order to let
your equipment run as efficiently and trouble free as possible. This
will also prevent your equipment from using too much energy.
E
UNIQU N BY
O
I
AT
INNOV IKIN
A
D
Extend product lifetime
The DNSS is designed to make sure that your equipment
is maintained and running as efficiently as possible.
This optimisation will extend the lifespan of your equipment.
Malfunction messages
In the unlikely event of a problem occurring, your regional
Daikin UK office will contact you directly. Our engineers, who are
dedicated to your installation, will inform you regarding the nature
of the problem and will help you towards the next step
of solving the problem.
Your installation under continuous monitoring
>
>
>
>
>
>
>
24/7, 365 days a year remote monitoring
Predictive maintenance
Improved reliability
Improved comfort levels
Helps increase efficiency
Helps reduce maintenance costs
Extends product lifetime
Extra value at low cost
> A strategy of preventing breakdowns and limiting
unnecessary maintenance visits
> Efficiently organising site interventions by diagnosing
the nature and the extent of the problem before
going to site
> Innovative technology that helps to optimise your
equipment’s potential
> Ensures the most comfortable environment in
your premises
Installation requirements:
> DNSS requires an Intelligent Touch Controller or
Intelligent Touch Manager to be installed on site, to act
as the data relay point
> The controller cost is not included in the
Commissioning price, but must be purchased separately
> A Lan connection must be provided local to the
installed controller with the ability to make an outgoing
connection to the internet
> Alternatively a 3G connection can be supplied by Daikin
at an additional cost
Commissioning
Model
Description
Trade Price
UK.FS-DNSS1-3VRV
UK.FS-DNSS4-6VRV
UK.FS-DNSS7-9VRV
UK.FS-DNSS10-12VRV
UK.FS-DNSS13-15VRV
UK.FS-DNSS16-18VRV
UK.FS-DNSS19-21VRV
DNSS is sold at nett price. No discounts will apply
DNSS commissioning of 1 to 3 VRV systems
DNSS commissioning of 4 to 6 VRV systems
DNSS commissioning of 7 to 9 VRV systems
DNSS commissioning of 10 to 12 VRV systems
DNSS commissioning of 13 to 15 VRV systems
DNSS commissioning of 16 to 18 VRV systems
DNSS commissioning of 19 to 21 VRV systems
£450.00
£500.00
£600.00
£700.00
£800.00
£1,000.00
£1,200.00
90
Residential, Commercial and Industrial
Annual monitoring
Model
Description
Trade Price
DNSS is sold at nett price. No discounts will apply
UK.FS-DNSS/VRV/IND Annual DNSS monitoring of a single
£150.00
module VRV system
UK.FS-DNSS/VRV/2ND Annual DNSS monitoring of a twin
£200.00
module VRV system
UK.FS-DNSS/VRV/3ND Annual DNSS monitoring of a triple
£250.00
module VRV system
VRV-Q Warranty
Warranty and site services
VRV
The warranty for VRV-Q systems operates under different conditions
from our standard warranty. To ensure complete suitability of the
existing site, a choice of optional warranty and special site services
packages are available from Daikin Airconditioning UK Ltd. These
choices will ensure the VRV-Q system is designed and commissioned
to provide the client with complete ‘peace of mind’ operation.
The choices include:
a)Pre-order checks on the existing pipework and fan coils installed
on the clients’ site to ensure suitability for VRV-Q installation
b)Commissioning of the new VRV-Q installation to ensure correct
and efficient operation
Warranty options for 3 or 5 years are available depending on the
qualification criteria and the type of system being installed.
Commissioning Log Books should be available for inspection by
Daikin Airconditioning UK Ltd if required.
The tables below provide an overview of the choices. For full details
please contact your local sales office.
VRV-Q Warranty Choices
1. VRV-Q combined with new fan coil units
Warranty Package Level
For Site with New Fan Coils
non D1/D1+
Condensing Unit Warranty Period
Fan Coil Unit Warranty Period
Site Pre-Order Inspection
Commissioning
D1/D1+
3 Years
5 Years
3 Years
5 Years
By trained approved engineer (1) OR by Daikin Airconditioning UK Ltd (additional cost)
By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost)
2. VRV-Q combined with existing fan coil units
Warranty Package Level
For Site with Existing Fan Coils
non D1/D1+
Condensing Unit Warranty Period
Existing Fan Coil Unit Warranty Period
Site Pre-Order Inspection
Commissioning
D1/D1+
3 Years
5 Years
0 Years
0 Years
By trained approved engineer (1) (2) OR by Daikin Airconditioning UK Ltd (additional cost)
By approved engineer (1) (subsequent projects) OR by Daikin Airconditioning UK Ltd (additional cost)
Notes:
Approved engineer to sign commissioning report and be able to identify DAUK official training programme attended, SE19 VRV-Q required
Trained approved engineer to collect 2 hours of data per system from the service checker for assessment
(1)
(2)
Daikin Support Options
Site pre-order inspection per system*
Site pre-inspection (existing fan coils) including 2 hour service
checker analysis per system*
Daikin commissioning per system*
Daikin full day commissioning assistance
Cost
Code
£175.00
£285.00
UK.SFV/N/INSP
UK.SFV/E/INSP
£400.00
£585.00
UK.SFV/SYCOMM
UK.SFV/FULLCOMM
*System is defined as a maximum of 3 connected condensers. All prices shown are Net. No further discount can be applied.
Price List 2016
91
VRV
VRV-Q Warranty Detail
Approved engineer
An approved engineer is an engineer who:
1. Is suitably registered in accordance with F-gas regulations
2.Has successfully completed a Daikin Airconditioning UK Ltd VRV Air Cooled
installation and commissioning course within the last 3 years
3. Has completed SE19 VRV-Q course in the past 3 years
•Check status of the existing indoor units – necessary if the existing units are
to be reused
• Check filter condition
• Check coil condition
• Check fan motor operation – select fan only and check for air movement and
for unusual noise and vibration
Net price
Net price, exclusive of VAT and subject to our standard terms and conditions.
No other discounts are applicable.
Prices shown for site pre-order inspection and commissioning are for work
undertaken during normal working hours between 09:00 and 17:30. Any request
for attendance to site out of these hours is subject to additional charges.
•Installed pipework details – necessary to check compliance with the
manufacturer’s specification and assess install quality. This would highlight any
required rectification prior to the installation of the new system
• Provide as installed pipework diagrams. If not available, provide as installed
pipe work schematics from information gathered on site
• Check the distance from the outdoor to the farthest indoor along the pipe
work route
• Check the distance from the first Refnet fitting to the farthest indoor unit
• Check the height difference between the outdoor and the lowest indoor
when the outdoor is situated above the indoor units or height difference
between the outdoor and the highest indoor if the outdoor is situated below
the indoor units
• Check the height difference between the highest and the lowest indoor
connected to the same system
• Provide the lengths of all installed pipe sizes
• Check the installation position and angle of the Refnet Joints
• Check the condition of the pipe insulation
• Check the adequacy of the existing pipe supports
Warranty
To activate the warranty, the Daikin Airconditioning UK Ltd VRV Commissioning
Log Book will need to be fully completed and submitted to Daikin Airconditioning
UK Ltd FQS department for checking. Upon receipt and validation that all required
details are provided and satisfactory, Daikin Airconditioning UK Ltd will issue a
confirmation letter that the warranty is activated. Where Daikin Airconditioning UK
Ltd will complete the commissioning, we will provide a copy of the Commissioning
Log Book to the installation contractor. Except where mentioned above, our
standard warranty conditions will apply. If none of the packaged options are
chosen, then the warranty will be limited to a standard 12 month parts only cover.
Site pre-order inspection
Where required, Daikin Airconditioning UK Ltd will attend the site to check the
suitability of the existing equipment and pipework for connection to VRV-Q. Where
it is not possible to check operation or equipment condition, this will also be
highlighted in the final report, and appropriate recommendations made.
If an approved engineer carries out the site inspection, then a Daikin
Airconditioning UK Ltd supplied form shall be completed and submitted to our
FQS department for checking and approval prior to any order being accepted.
The pre-order site inspection will include the following items:
•Existing system(s) capacity – necessary to estimate required system load for
the new system
• Record all the model numbers and the serial numbers for the indoor and the
outdoor units and indicate actual installed system combinations
92
Residential, Commercial and Industrial
•Installed communication and control wiring – necessary to check
compliance with the manufacturer’s specification, suitability for the new system
and suitability for new controls specification
• Check sizes and type of the interconnecting communication cables between
indoor units, outdoor units and any central control systems
• Check the separation between the power wiring and the installed
controls wiring
•Power wiring to the outdoor units – necessary to check suitability for the
new outdoor units
• Check supply voltage
• Check number of outlets available adjacent to the outdoor units compound
• Check fuse/MCB sizes and types
• Check status of the isolators
•
System health checks – it is important to know if the existing systems are
operating to their optimum. If there are issues which may affect the new
installation they need to identified and rectified before installation of the
new system. A comprehensive list of the operating data can be collected
by connecting a VRV Checker to each system and recording a minimum of
one hour operation data for analysis. This data should be sent back to Daikin
Airconditioning UK Ltd FQS department for analysis
• Operate the whole system in cooling for ½ hour and in heating for ½ hour to
collect representative data
• Send data to Daikin Airconditioning UK Ltd FQS department for analysis
•System history check – although the new VRV-Q system is designed to re-use
existing pipework and in some cases existing indoor units it is still necessary to
know the existing systems operational history to judge its integrity for the new
application
• Check for presence of leak protection dye and acid level – use total test kit
• Ensure that no Acid Away chemical has ever been added to the system
refrigerant charge
•Existing system controls – investigate currently installed local controls,
centralised controls and connection to the third party systems. This is
particularly necessary if any existing controls are planned to be re-used
Commissioning
Dependant on the requirement, either an approved engineer or Daikin
Airconditioning UK Ltd will provide system commissioning on the completed
installation. As mentioned in the warranty section above, a completed log book
will need to be submitted to activate the warranty
Commissioning where not provided by Daikin Airconditioning UK Ltd, can only be
completed by an approved engineer.
Where Daikin Airconditioning UK Ltd provides commissioning as part of the
package this shall include:
•Check installation of new units – ensure new piping is installed correct to
Daikin specification
• Check power supplies – local isolators, MCB rating
• Fill in model number data, serial numbers etc. to commissioning log book
• Initialise VRV System and ensure all units communicate
• Set up additional control systems – ITC, Bacnet and provide demonstration
• Charge additional refrigerant
• Perform “Test” operation – including “Automatic” charging function
• Connect service checker and monitor operation – Cool>Heat>Heat Recovery
• Complete Commissioning Log Book
• Provide additional comments and recommendations if necessary
• Leave operation set as required by client
DNSS (Daikin Network Service System)
Where Daikin Airconditioning UK Ltd provide DNSS this shall include the
following items:
• Commissioning of DNSS system (on-site service)
• GPRS router and SIM (this will be property of Daikin Airconditioning UK Ltd)
• Remote energy saving service
• 24/7 monitoring of VRV operating data
• Instant notification of system malfunction (email) 7 days a week
• Malfunction prediction service (during office hours 09.00 - 17.30)
•Bi-annual energy saving report indicating electricity cost saving and reduction
in CO2 emissions
•Recommendations to improve operating settings
•Issue of a DNSS user pack
All of the above will be provided for the warranty period of the VRV (either 3 or 5
years) depending on the package selected.
Prior to our site attendance the following shall be completed:
•A device compatible with DNSS is installed on site – Daikin Intelligent Manager,
Daikin Intelligent Touch Controller or Daikin LC controller. (Not included in the
price of the monitoring package)
•All electrical work is complete and correct (supply wiring type and size –
breaker size correct) also F1/F2 communications are installed
•A full set of as installed drawings are available – indicating system
configurations, installation locations and room references
•A power source is installed for the GPRS modem near the control device –
this can be powered from a standard socket
•A connection to the internet is available – for areas where there is poor GPRS
coverage a LAN or analogue phone connection must be installed near the
control device. (Installation and rental costs are not included in the price of the
monitoring package)
•Full access must be made available to the VRV equipment and if any access
equipment is required Daikin UK must be informed prior to the site visit
•A list of contacts must be issued to Daikin Airconditioning UK Ltd (these
are the contacts that should be e-mailed or telephoned in the event of a
malfunction or error with the air conditioning system). If these change in
the future, information will be given in the user pack for how to notify Daikin
Airconditioning UK Ltd of the changes
This is an extract from the Daikin publication “Warranty and Site Services Package
for VRV-Q”. Please contact your local sales office to receive a copy and obtain
further information.
Prior to our site attendance the following shall be completed:
• All communication wiring is complete and terminated correctly
•All electrical work is complete and correct (supply wiring type and size –
Breaker size correct)
•All systems piping has been pressure tested to 33 Bar
•All systems piping has been evacuated to < 5 Torr
•All systems piping has been measured and is available for our information
•Sufficient additional refrigerant is available on the day
Any other works other than those detailed above are excluded.
Price List 2016
93
VRV
VRV-Q Warranty Detail
RWEYQ-T8
Water Cooled VRV
VRV
Water cooled VRV uses water as its source of heat. This enables not just heat recovery on each system,
but also heat recovery between different systems, maximising efficiency. Additionally there is no
defrost required on these units meaning heating comfort is maintained even during cold spells.
Ideal for large buildings
VRV-W systems are capable of coping with water pressures of 2MPa and provide pipework lengths of up to 120m length from
condenser to fan coils.
The new VRV IV features are available on water cooled
VRV systems including:
> T he standard model is now capable of accepting geothermal
water temperatures (Down to -10 Deg C with glycol)
> V
ariable Refrigerant Temperature – delivering far higher
efficiency than any other comparable system and ensuring
comfort by raising off coil temperatures, Variable Refrigerant
Temperature control delivers a leap forwards in VRV technology.
> Inverter water pump controller (available on request)
> C
onfigurator – Simplified commissioning: graphical interface
to configure, commission and upload system settings. Manage
systems over multiple sites, saves time and reduces errors during
set-up and commissioning.
> C
onnect to AHU applications and Heat Reclaim Ventilation devices
> N
ow it’s even possible to connect VRV IV BS boxes, including the
small, light Multi BS boxes designed to offer the largest & most
flexible range of design & installation options available.
Water flow control
Significantly reduce inverter pump power input by reducing the
flow through the VRV-W condenser when at part load.
By linking the degree of valve opening to the compressor
frequency, the flow rate varies to match the load.
Consequently as the flow rate reduces, the inverter pump will slow
down and save energy.
> Up to 13 steps of flow control available
> Available as an option (factory fitted)
> 50l/m minimum flow rate
Chiller / Boiler
Variable water
Flow Control Valve
Wired connection
Inverter Pump
94
Residential, Commercial and Industrial
Heat Pump and Heat Recovery RWEYQ-T8 (up to 24 hp)
VRV IV Water Cooled Condensing Units
Capacity
EER
COP
Dimensions
Weight
Electrical
Details
Refrigerant
Circuit
RWEYQ8T8 RWEYQ10T8
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
Phase / Hz / V
amps
amps
amps
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
22.40
25.00
5.07
5.94
1000
780
550
137
7.2
4
20
kg
kg
Sound Pressure
dBA
Piping Limits
Maximum Length
m
Maximum Vertical Rise
m
Liquid
inch (mm)
Piping
Connections
Gas (Heat pump) Suction (HR) inch (mm)
Gas Discharge (HR only)
inch (mm)
Drain
Outlet
Water
Inlet & Outlet
Capacity Index Limit
Maximum Number of Connected Indoor Units
3.5
data book
50
120
50
3/8 (9.52)
3/4 (19.1)
5/8 (15.9)
Trade Condensing Unit Price
£5,524.00 £6,807.00
100~260
36
RWEYQ16T8
RWEYQ18T8
RWEYQ20T8
RWEYQ24T8
RWEYQ8T8 RWEYQ8T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ8T8 RWEYQ8T8 RWEYQ8T8
28.00
44.80
50.40
56.00
67.20
31.50
50.00
56.50
63.00
75.00
4.56
5.07
4.77
4.56
5.07
5.25
5.94
5.53
5.25
5.94
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
780
780
780
780
780
780
780
780
780
780
550
550
550
550
550
550
550
550
550
550
137
137
137
137
137
137
137
137
137
137
3 / 50 / 380~415
9.5
14.4
16.7
19.0
21.6
4
4
4
4
4
20
32
32
32
50
R410A
4.2
3.5
3.5
3.5
4.2
4.2
4.2
3.5
3.5
3.5
data book
data book
data book
data book
data book
51
53
54
54
55
120
120
120
120
120
50
50
50
50
50
3/8 (9.52)
1/2 (12.7)
5/8 (15.9)
5/8 (15.9)
5/8 (15.9)
7/8 (22.2)
1 1/8 (28.6)
1 1/8 (28.6)
1 1/8 (28.6)
1 3/8 (34.9)
3/4 (19)
7/8 (22.2)
7/8 (22.2)
7/8 (22.2)
1 1/8 (28.6)
ISO 228 - G1 1/2 B Internal thread - Per module
ISO 228 - G1 1/4 B External thread - Per module
125~325
200~520
225~585
250~650
300~780
36
36
36
36
36
£11,048.00
£12,331.00
£13,614.00
£16,572.00
Notes:
Daikin have introduced the new VRV IV Water Cooled condensing unit to complement the rest of the VRV range.
The water cooled system has a number of advantages over an air cooled system:
• suitable for tall multi-storied buildings due to no limitations of water piping length
• wide operation range with inlet water temperatures of -10°C to + 45°C
• suitable for use with open and closed loop ground source systems on request
• the system offers greater efficiency in heating mode as there is no defrost cycle required for the water loop
• greater efficiencies than air cooled systems
Heat Pump and Heat Recovery RWEYQ-T8 (26 to 30 hp)
VRV IV Water Cooled Condensing Units
Outdoor Units
RWEYQ26T8
RWEYQ8T8
Capacity
EER
COP
Dimensions
Weight
Electrical
Details
Refrigerant
Circuit
Nominal Cooling
Nominal Heating
kW
kW
Height
Width
Depth
mm
mm
mm
kg
Phase / Hz / V
amps
amps
amps
Power Supply
Running Current
Starting Current
Fuse Rating
Refrigerant Type
Refrigerant Charge
Additional Charge
kg
kg
Sound Pressure
dBA
Piping Limits
Maximum Length
m
Maximum Vertical Rise
m
Liquid
inch (mm)
Piping
Connections
Gas (Heat pump) Suction (HR) inch (mm)
Gas Discharge (HR only)
inch (mm)
Drain
Outlet
Water
Inlet & Outlet
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
1000
780
550
137
3.5
RWEYQ28T8
RWEYQ30T8
RWEYQ8T8 RWEYQ10T8 RWEYQ8T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8 RWEYQ10T8
72.80
78.40
84.00
81.50
88.00
94.50
4.86
4.69
4.56
5.65
5.43
5.25
1000
1000
1000
1000
1000
1000
1000
1000
780
780
780
780
780
780
780
780
550
550
550
550
550
550
550
550
137
137
137
137
137
137
137
137
3 / 50 / 380~415
23.9
26.2
28.5
4.0
4.0
4.0
50
50
50
R410A
3.5
4.2
3.5
4.2
4.2
4.2
4.2
4.2
data book
55
55
56
120
120
120
50
50
50
3/4 (19.1)
3/4 (19.1)
3/4 (19.1)
1 3/8 (34.9)
1 3/8 (34.9)
1 3/8 (34.9)
1 1/8 (28.6)
1 1/8 (28.6)
1 1/8 (28.6)
ISO 228 - G1 1/2 B Internal thread - Per module
ISO 228 - G1 1/4 B External thread - Per module
325~845
350~910
375~975
36
36
36
£17,855.00
£19,138.00
£20,421.00
Notes:
The VRV IV Water Cooled system is supplied as a common unit and can be used in either heat pump and heat recovery modes, from size 10 to size 30 all using a three phase power supply.
The 30 hp system can connect to up to 36 indoor units. The system is fully compatible with the full range of existing VRV fan coils and controls packages. It should be installed in a plant room.
Price List 2016
95
VRV
Outdoor Units
BS-Q-A
VRV Accessories VRV IV Branch Selector Boxes – Heat Recovery
VRV
The new VRV IV Heat Recovery series has a new
range of BS boxes, which are designed to offer
unrivalled flexibility – enabling you to install
and adapt the systems in as little time, effort
and cost as possible.
BS1Q10,16,25A
Main features:
BS4Q14A
BS6,8Q14A
BS10,12Q14A
BS16Q14A
> Unlimited unused ports
> Smaller, lighter and quieter than comparable products
> Fan coils up to 140 class can be attached to a single port
All VRV IV Heat Recovery, VRV III-Q replacement and Water Cooled VRV (RWEYQ-T8) now use VRV IV Multi Boxes.
Single Boxes for VRV IV Heat Recovery
(REYQ-T / RWEYQ-T8 / RQEQ-P3)
Dimensions
Weight
Total Indoor Capacity
Number of Fan Coil Units
Electrical Details
HxWxD
Piping Limits
Piping Connections Indoor
Piping Connections Outdoor
Power Supply
Power Input
Fuse Rating
Level Difference
Maximum Length
Liquid
Gas
Liquid
Suction
Discharge
Single Boxes
BS1Q10A
mm
kg
Trade Accessory Price
Dimensions
HxWxD
Weight
Branches per box
Capacity index of each branch
Number of Fan Coil Units per branch
Total Indoor Capacity Index
Total number of Fan Coil units per box
Electrical Details
Power Supply
Power Input
Fuse Rating
Piping Limits
Level Difference
Maximum Length
Piping Connections Indoor
Liquid
Gas
Piping Connections Outdoor
Liquid
Suction
Discharge
BS1Q25A
3/8 (9.5)
5/8 (15.9)
3/8 (9.5)
5/8 (15.9)
1/2 (12.7)
£337.00
£372.00
12
15 ~ 100
6
Phase / Hz / V
kW
amps
m
m
inch (mm)
inch (mm)
inch (mm)
inch (mm)
inch (mm)
Multi Boxes for VRV IV Heat Recovery
(REYQ-T / RWEYQ-T8 / RQEQ-P3)
BS1Q16A
207 x 388 x 326
12
101 ~ 160
8
1 / 50 / 230
0.005
15
data book
data book
3/8 (9.5)
5/8 (15.9)
3/8 (9.5)
5/8 (15.9)
1/2 (12.7)
15
161 ~ 250
8
3/8 (9.5)
7/8 (22.2)
3/8 (9.5)
7/8 (22.2)
3/4 (19)
£427.00
Multi Boxes
BS4Q14AV1
mm
kg
298 x 370 x 430
17
4
BS6Q14AV1
BS8Q14AV1
BS10Q14AV1
298 x 580 x 430
24
6
26
8
BS16Q14AV1
38
12
298 x 1060 x 430
50
16
50
60
64
0.107
15
0.129
15
0.172
15
35
10
140 or less
5 per branch
400 or less
20
Phase / Hz / V
kW
amps
m
m
inch (mm)
inch (mm)
inch (mm)
inch (mm)
inch (mm)
Trade Accessory Price
600 or less
30
750 or less
40
1 / 50 / 230
0.043
15
0.064
15
0.086
15
Data Book
3/8 (9.5)
5/8 (15.9)
3/8 (9.5)
7/8 (22.2)
3/4 (19)
3/8 (9.5)
5/8 (15.9)
1/2 (12.7)
1 1/8 (28.6)
3/4 (19)
3/8 (9.5)
5/8 (15.9)
1/2 (12.7)
1 1/8 (28.6)
3/4 (19)
3/8 (9.5)
5/8 (15.9)
5/8 (15.9)
1 1/8 (28.6)
1 1/8 (28.6)
3/8 (9.5)
5/8 (15.9)
5/8 (15.9)
1 1/8 (28.6)
1 1/8 (28.6)
3/8 (9.5)
5/8 (15.9)
3/4 (19)
1 3/8 (34.9)
1 1/8 (28.6)
£1,550.00
£2,123.00
£2,792.00
£3,357.00
£4,114.00
£5,008.00
Accessories:
Accessory Ref
Description
Trade Price
KHRP26A250T
KHFP26M224
KHFP26A100C
Junction pipe kit to link two Multi BS ports to connect 20 and 25kW fan coils
Stop valve kit for multi BS box future expansion without refrigerant recovery
Pipe closing kit for unused ports
£280.00
£92.00
£45.00
96
BS12Q14AV1
298 x 820 x 430
Residential, Commercial and Industrial
VRV Accessories VRV IV Branch Selector Boxes with Pre-fitted Valves
One of the main benefits of the Daikin VRV multi BS
boxes is the flexibility they offer when changing the
layout of the system to cater for the changing tenant
needs on a building.
To further increase the flexibility of the BS boxes, we now offer
the full range of multi BS boxes with pre-fitted valves.
Having valves pre-installed on the boxes can save considerable
time and effort on site.
Pre-installed valves allow:
VRV
> Indoor units to be added without altering system pipework
>New units can be added without having to remove refrigerant
from the rest of the system
• So you can avoid having to pump down / vac out /
recharge the whole system
• Saves many man hours when altering systems
Note: Providing index is not increased above the next pipework threshold or the BS box index limit
Model No
No. of Ports
Original Depth
Original Weight
*Weight with Valves
UK.BS4Q14AV1/FSV
UK.BS6Q14AV1/FSV
UK.BS8Q14AV1/FSV
UK.BS10Q14AV1/FSV
UK.BS12Q14AV1/FSV
UK.BS16Q14AV1/FSV
4
6
8
10
12
16
mm
kg
kg
430
BS Box Price
Valve Modification Price**
17
22
24
31
26
34
35
45
38
49
50
64
£1,550.00
£255.00
£2,123.00
£357.00
£2,792.00
£459.00
£3,357.00
£561.00
£4,114.00
£663.00
£5,008.00
£867.00
* Approx
** Not subject to standard trade discount
RXYSQ, RYYQ, REYQ, RWEYQ
VRV Condensing Unit – Refnet Joints
For Outdoor Units
2-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units RXYSQ / RYYQ / RWEYQ
Total Capacity of
Indoor Units
RXYQ5P /
RXYSCQ /
RXYSQ4-6PA
RYYQ8-54T /
RWEYQ-T
Liquid
Pipe
Suction
Pipe
Below 62.5
1/4
1/2
KHRQ22M20T
£29.00
62.5 to 162.5
3/8
5/8
KHRQ22M20T
£29.00
KHRQ22M20T
KHRQ22M20T
KHRQ22M29T9
KHRQ22M64T
KHRQ22M64T
KHRQ22M75T
KHRQ22M29H
KHRQ22M64H
KHRQ22M75H
BHFQ22P1007
BHFQ22P1517
BHFP22P36C
BHFP22P54C
£29.00
£29.00
£36.00
£38.00
£38.00
£48.00
£114.00
£139.00
£182.00
£78.00
£153.00
£96.00
£191.00
Below 150
150 to below 200
200 to below 290
290 to below 420
420 to 639
640 and above
3/8
5/8
3/8
3/4
3/8
7/8
1/2
1 1/8
5/8
1 1/8
Please contact your local sales office for selection
Refnet Header
Refnet Header
Refnet Header
Condensing Unit Branch Kit - 2 Module RYYQ, RWEYQ
Condensing Unit Branch Kit - 3 Module RYYQ
Condensing Unit Branch Kit - 2 Module RQYQ
Condensing Unit Branch Kit - 3 Module RQYQ
For Outdoor Units
RWEYQ8-30T /
REYQ-T
Trade Price
Refnet
Selection
3-Pipe System Refrigerant Sizing between Refnet Joints and Indoor/Outdoor Units REYQ / RWEYQ
Total Capacity of
Indoor Units
Liquid
Pipe
Below 150
150 to below 200
200 to below 290
290 to below 420
420 to 639
640 and above
3/8
3/8
3/8
1/2
5/8
Discharge
Pipe
1/2
5/8
3/4
3/4
1 1/8
Please contact your local sales office for selection
Refnet Header
Refnet Header
Refnet Header
Condensing Unit Branch Kit - 2 Module REYQ, RWEYQ
Condensing Unit Branch Kit - 3 Module REYQ, RWEYQ
Condensing Unit Branch Kit - 2 Module RQEQ
Condensing Unit Branch Kit - 3 Module RQEQ
Condensing Unit Branch Kit - 4 Module RQEQ
Trade Price
Suction
Pipe
Refnet
Selection
5/8
3/4
7/8
1 1/8
1 1/8
KHRQ23M20T
KHRQ23M20T
KHRQ23M29T9
KHRQ23M64T
KHRQ23M64T
KHRQ23M75T
KHRQ23M29H
KHRQ23M64H
KHRQ23M75H
BHFQ23P907
BHFQ23P1357
BHFP26P36C
BHFP26P63C
BHFP26P84C
£42.00
£42.00
£55.00
£58.00
£58.00
£72.00
£157.00
£190.00
£267.00
£145.00
£293.00
£164.00
£333.00
£442.00
Price List 2016
97
NEW
Mini
Building
Management
System
Mini
NEW
MiniBuilding
BuildingManagement
ManagementSystem
System NEW
Mini Building Management System NEW
Mini Building Management System NEW
User friendly
User
friendliness
User
Userfriendliness
friendliness
>User
Intuitive
user interface
friendliness
Intuitive
user
interface
V
isual
layout
view and direct access to indoor
› ››>
Intuitive
user
User
friendliness
Intuitive
userinterface
interface
lay
out
view
and
direct
access
indoor
unit
unitlay
main
functions
› ››Visual
view
and
› Visual
Intuitive
user
interface
Visual
layout
out
view
anddirect
directaccess
accesstoto
toindoor
indoorunit
unit
funtions
>
A
ll
functions
direct
accessible
via
touch
screen
main
funtions
› main
Intuitive
user
interface
Visual
lay
out
view
and
direct
access
to
indoor
unit
main funtions
functions
direct
accessible
via
touch
screen
or
viafuntions
web
interface
› ››All
functions
direct
touch
› All
Visual
lay
out
viewaccessible
and directvia
access
toscreen
indoor
main
All
functions
direct
accessible
via
touch
screen unit
via
web
interface
or
via
web
interface
main
funtions
› or
All
functions
direct accessible via touch screen
or
via
web
interface
› All
functions
direct accessible via touch screen
or via
web interface
Smart
energy
management
energy
management
Smart
management
or viaenergy
web
interface
Smart
energy
management
Smart energy management
Monitoring
use
plan
Monitoring
ifenergy
energy
use
isaccording
according
plan
› ››>
Monitoring
if ififenergy
use
isis
toto
plan
Smart
energy
management
Monitoring
energy
use
isaccording
according
toto
plan
detect
origins
waste
Helps
detect
origins
ofenergy
waste
› ››>
Helps
toto
detect
origins
ofof
waste
› Helps
Monitoring
if energy
use
isenergy
according
to plan
Helps
toto
detect
origins
ofenergy
energy
waste
schedules
guarantee
correct
operation
P
owerful
schedules
guarantee
correct
operation
› ››>
Powerful
schedules
guarantee
correct
› Powerful
Monitoring
if
energy
use
is
according
to
plan
Helps
to
detect
origins
of
energy
waste
Powerful schedules guarantee correctoperation
operation
the
year
throughout
the
yearguarantee
throughout
the
year
› throughout
Helps
to detect
origins
of energy
wasteoperation
Powerful
schedules
correct
throughout
the
year
energy
interlocking
A/C
operation
with
other
Save
energy
by
interlocking
operation
› ››>
Save
energy
byby
interlocking
A/C
operation
with
› Save
Powerful
schedules
guarantee
correct
operation
throughout
the
year
Save
energy
by
interlocking
A/CA/C
operation
withother
other
equiment
such
as
heating
with
other
equipment
such
as
heating
equiment
such
as
heating
throughout
the
year
› equiment
Save energy
by as
interlocking
such
heating A/C operation with other
› Save
energysuch
by interlocking
equiment
as heating A/C operation with other
Flexibility
Flexibility
equiment such as heating
Flexibility
Flexibility
Flexibility
Cross-pillar
integration
(heating,
conditioning,
› ›Cross-pillar
NEW
NEW
Cross-pillarintegration
integration(heating,
(heating,airair
airconditioning,
conditioning,
NEW ›Flexibility
systems,
refrigeration,
handling
units)
>
Cross-pillar
integration
(heating,
air conditioning,
conditioning,
applied
systems,
refrigeration,
airair
units)
› applied
Cross-pillar
integration
(heating,
air
applied
systems,
refrigeration,
airhandling
handling
units)
››BACnet
protocol
for
3rd
party
products
integration
applied
systems,
refrigeration,
airair
handling
units)
protocol
for
3rd
integration
› BACnet
Cross-pillar
integration
(heating,
conditioning,
applied
systems,
refrigeration,
air
handling
units)
BACnet
protocol
for
3rdparty
partyproducts
products
integration
››>
I/O
for
integration
of
equipment
such
as
lights,
B
ACnet
protocol
for
3rd
party
products
integration
I/O
for
integration
of
equipment
such
as
lights,
applied
systems,
airsuch
handling
units)
› I/O
BACnet
protocol refrigeration,
for
3rd party products
for integration
of equipment
asintegration
lights,
on
WAGO
modules
>› pumps…
I/O for
for integration
integration
of
equipment
such as
as
lights,
on
modules
BACnet
protocol
for
3rd
party products
integration
I/O
of
equipment
such
lights,
pumps…
onWAGO
WAGO
modules
NEW pumps…
concept
for
small
large
applications
pumps
etc.
WAGO
modules
› ››Modular
concept
for
small
toto
applications
› Modular
I/O
for integration
of
equipment
as lights,
pumps…
onon
WAGO
modules
Modular
concept
for
small
tolarge
largesuch
applications
up
to
512
indoor
unit
via
one
ITM
Modular
concept
formodules
small
togroups
largevia
applications
› ››>
Control
up
to
unit
groups
pumps…
on
WAGO
› Control
Modular
for
small
large
applications
Control
upconcept
to512
512indoor
indoor
unitto
groups
viaone
oneITM
ITM
and
combine
multiple
ITM
via
the
web
interface
>
C
ontrol
up
to
512
indoor
unit
groups
via
one
ITM
and
combine
multiple
ITM
via
the
web
interface
› and
Modular
concept
for small
to groups
large
applications
Control
up
tomultiple
512 indoor
viainterface
one ITM
combine
ITMunit
via
the web
and
combine
multiple
ITM
via
the
web
interface
› Control
up to 512
indoorITM
unit
viainterface
one ITM
and combine
multiple
viagroups
the web
Plug
play
Plug
Plug&&
&play
play
Plug & play
Plug & play
NEW
NEW
NEW
NEW›
NEW
NEW›
Split
Split
Split
Fancoils
coils
Fan
Fan coils
Chillersand
andAHU
AHU Refrigeration
Refrigeration
Chillers
Chillers and AHU Refrigeration
Split
Fan coils
Chillers and AHU
Refrigeration
Split
Fan coils
Chillers and AHU
Refrigeration
Easy
servicing
and
commissioning
Easy
servicing
and
combine and
multiple
ITM via the web interface
Easy
servicing
andcommissioning
commissioning
Easy servicing and commissioning
Remote
refrigerant
containment
check
preventing
servicing
and
commissioning
› ››Easy
Remote
refrigerant
containment
check
Easy
servicing
and
commissioning
Remote
refrigerant
containment
checkpreventing
preventing
site
visit
on
site
› on
Remote
refrigerant containment check preventing
on
sitevisit
visit
››>
troubleshooting
R
emote
refrigerant
containmentcheck
checkpreventing
Simplifi
ed
troubleshooting
› Simplifi
Remote
refrigerant
containment
on
site
visit
Simplified
ed
troubleshooting
››Save
time
on
commissioning
preventing
on
site visit
time
on
commissioning
on
site
visit
› Save
Simplifi
ed
troubleshooting
Save
time
on
commissioning
to
the
pre-commissioning
tool
>
Simplified
troubleshooting
thanks
to
the
pre-commissioning
› thanks
Simplifi
troubleshooting
Save
time
on
commissioning tool
thanks
toed
the
pre-commissioning
tool
Auto
registration
of
indoor
units
S
ave
time
on
commissioning
thanks
› ››>
Auto
registration
of
indoor
units
› Auto
Save
time
on commissioning
thanks
to the
pre-commissioning
registration
of indoor units tool to the
pre-commissioning
tool units tool
to the pre-commissioning
› thanks
Auto
registration
of indoor
>› Auto
Autoregistration
registrationofofindoor
indoorunits
units
›
›
Functions
overview
Functions
Functionsoverview
overview
Functions overview
Functions overview
Functions overview Languages
Management
Languages
Languages
98
Residential,
Flexibilityininsize
size
Flexibility
Flexibility in size
From6464upuptoto∞∞number
number
From
Flexibility
in number
size
From 64
up to ∞
ofgroups
groups
of
FromFlexibility
64ofup
to in
number
groups
∞size
From 64 of
upgroups
to ∞ number
of groups
Control
Management
Management
Management
Control
Control
Control
Connectable to Connectable
Connectabletoto
Connectable to
English
Webaccess
access
Individualcontrol
control
- DXSplit,
Split,Sky
SkyAir,
Air,
VRV
› ›English
› ›Web
› ›Individual
-Connectable
DX
VRV
> DX Split, Sky Air, VRV
› Languages
English > Web access
› Management
Web access > Individual control› Control
Individual control
- DX Split, Sky Air, to
VRV
French >Power Proportional› ›Power
PowerProportional
Proportional
(2,560
groups)
Chillers
(via
POL638.70
controller)
› ›French
(2,560
groups)
Chillers
(via
POL638.70
> Chillers (via POL638.70
>Schedule setting (weekly
Control
Connectable
› French
English
› Power
Web access
› (2,560
Individual
control
DXcontroller)
Split,
Sky
Air,to
VRVcontroller)
› Languages
› Management
Proportional
groups)
- -Chillers
(via
POL638.70
controller)
German Distribution (option) Distribution
Distribution(option)
(option)
›Schedule
Schedulesetting
setting
(Weekly
- DaikinAHU
AHU
› ›German
›
(Weekly
Daikin
NEW
NEW
>
Daikin
AHU
schedule,
yearly
calender,
English
›› Distribution
Web
access
Individual
control(Weekly NEW ---Daikin
DX
Split,
SkyPOL638.70
Air, VRV controller)
French
Power
Proportional
(2,560 groups)
Chillers
(via
› ›› German
(option)
› › Schedule
setting
AHU
Italian >Operational history› ›Operational
Operationalhistory
history
schedule,yearly
yearly
calender,
- Fancoils
coils
› ›Italian
>calender,
Fan
coils NEW- Fan
seasonal schedule)schedule,
French
Power
Proportional
(2,560
groups)
Chillers
(via POL638.70 controller)
German
Distribution
(option)
› schedule,
Schedule
setting
(Weekly
Daikin
› ›› Italian
› › Operational
history
yearly
calender,
---Fan
coilsAHU
Spanish (malfunctions, operation
seasonalschedule)
schedule)
- Daikin
AlthermaFlex
Flextype
type
(malfunctions,
operation
hours,
> Daikin
Altherma Flex
type
>
Interlock
control
› ›Spanish
seasonal
Altherma
(malfunctions,
operation
…)…)
German
Distribution
(option)
› seasonal
Schedule
setting
(Weekly NEW- Daikin
Daikin
AHU
Italian
› (malfunctions,
Operational
historyhours,
schedule,
yearly calender,
Fan coils
› ›› Spanish
schedule)
---Daikin
Altherma
Flex type
operation
hours, …)
> LT and HT hydroboxes
hours, …)
>
Setpoint limitation
Dutch
›Interlock
Interlockcontrol
control
- LTand
andHTHThydroboxes
hydroboxes
›Smart
Smartenergy
energy
management
› ›Dutch
›
LT
›
management
Italian
Operational
schedule,
yearly calender,
Fan
coils
Spanish
seasonalcontrol
schedule)
Daikin
Altherma
Flex type
(malfunctions,
operation
hours, …)
› ›› Dutch
› Interlock
---LT
and
HT
hydroboxes
› › Smart
energyhistory
management
> Air curtains
>Smart energy management
> Temperature
limit
Portuguese
Setpointlimitation
limitation
- Aircurtains
curtains
- monitorif ifenergy
energy
useis is
› ›Portuguese
› ›Setpoint
- Air
-›monitor
use
Spanish
seasonal
schedule)
Daikin
Flex type
operation
Dutch
Interlocklimitation
control
LT curtains
and Altherma
HT hydroboxes
Smart
energy
management
› ›› Portuguese
› › Setpoint
---Air
-(malfunctions,
monitor
if energy
usehours,
is …)
> WAGO I/O, AO and
PI I/O,
–monitor if energy useaccording
is
Temperaturelimit
limit
- WAGO
I/O,AO
AOand
andPIPI
plan
› ›Temperature
- WAGO
toto
›› Dutch
Interlock
LT
HT AO
hydroboxes
› according
Smart
energy
management
Portuguese according to plan according
Setpoint control
limitation
Airand
curtains
- monitor
ifplan
energy
use is
› ›› Temperature
limit
I/O,
and PI
to
plan
> BACnet protocol ----WAGO
BACnet
protocol
- detectorigins
originsofofenergy
energy
System
layout
BACnet
protocol
detect
System
layout
NEW
NEW
› Portuguese
›› Setpoint
limitation
Air
curtains
monitor
iftoenergy
use is
Temperature
limit
WAGO
I/O,
AO and PI
plan
protocol
--according
detect
origins
of energy
System
NEW ---BACnet
>
WAGO Interface
layout
–detect origins of energy
waste
Uptoto2,560
2,560unit
unitgroups
groupscan
can
waste
› ›Up
› Temperature limit
AO and PI
according
to plan
BACnetI/O,
protocol
- detect origins
of energy
layout
waste
› System
Up to 2,560
unit
groups can
NEW -- WAGO
waste
›Setback
Setbackfunction
function
becontrolled
controlled
WAGO
Interface
›
be
WAGO
-waste
detectfunction
origins of energy
System
layout
› be
Upcontrolled
to 2,560
unit groups
can
>Setback
function
› Setback
WAGOInterface
Interface
NEW - BACnet protocol
Slidingtemperature
temperature
(ITMplus
plusIntegrator
Integrator+temperature
+7 iPU
7 iPU
Modularintegration
integrationofof3rd
3rd
› ›Sliding
(ITM
› ›Modular
>Sliding
waste
› (ITM
Up
to
2,560
unit groups
can
Setback
function
be controlled
› › Sliding
temperature
plus
Integrator
+ 7 iPU
› WAGO
Modular Interface
integration of 3rd
(incl.iTM
iTMadaptor)
adaptor)
partyequipment
equipment
(incl.
party
›› Setback
function
be
controlled
WAGO
Interface
Sliding temperature
(ITM
plusadaptor)
Integrator + 7 iPU
› party
Modular
integration of 3rd
(incl.
iTM
equipment
Ethernet
TCPIP
- WAGOcoupler
coupler(interface
(interface
› ›Ethernet
TCPIP
-› WAGO
› Sliding temperature
(ITM
Integrator
integration
of 3rd
(incl.plus
iTM
adaptor) + 7 iPU
party
› Ethernet
TCPIP
-Modular
WAGOequipment
coupler
(interface
betweenWAGO
WAGOand
andModbus)
Modbus)
between
iTM TCPIP
adaptor)
party
equipment
› (incl.
Ethernet
- WAGO
coupler
(interface
between
WAGO and
Modbus)
- Dimodule
module
- Di
› Ethernet TCPIP
WAGO
coupler
(interface
between
WAGO
and
Modbus)
- Di module
- Domodule
module
- Do
Commercial and Industrial
WAGO and Modbus)
-Do
Di module
-between
- Aimodule
module
- Ai
Di
module
Do
module
---Ai
module
- Thermistormodule
module
- Thermistor
Control Systems
Control
Control
Systems
Systems
Control
Systems
Control
Systems
VRV
VRV Accessories Mini Building Management System
NEW
NEW
Mini Building Management System
Mini Building Management System
Check on
Check on
https://www.youtube.com/
https://www.youtube.com/
DaikinEurope
DaikinEurope
VRV
Accessories System Overview
DCM601A51
DCM601A51
with
with full
full integration
integration
across
across all
all product
product pillars
pillars
Price competitive mini BMS
Price competitive mini BMS
Cross-pillar integration of Daikin products
Cross-pillar integration of Daikin products
Integration of third party equipment
Integration of third party equipment
VRV
Mini BMS
•
•
•
•
•
•
System overview
System overview
Web Access
Web Access
Internet
Extranet
Internet
LAN
Extranet
3G
LAN
http interface
3G
http interface
Integration of third
Integration
of third
party
equiqment
party equiqment
Full control of Daikin
Full HVAC-R
control of
Daikin
portfolio
HVAC-R portfolio
DCM601A51
DCM601A51
ITM plus adaptor line
ITM plus adaptor line
Di/Pi line
Di/Pi200m
line
Max.
Max. 200m
Fire alarm
Fire alarm
Di/Pi port
Di/Pi port
kWh meter
kWh meter
Max. 7
adapters
Max. 7
adapters
DCM601A52
DCM601A52
Direct plug & play connection!
Direct plug & play connection!
Lighting
Lighting
Fan
Fan
Pump
Pump
Sensor
Sensor
air
curtain,
hydrobox,
hydrobox,
air handling
units
air handling units
Refrigeration
Referigeration
Referigeration
indoor units,
indoor
units,
air curtain,
Chillers
Chillers
andand
AHU
AHU
WAGO
WAGO
interface
interface
I/OI/O
module
module I/OI/O
module
module
BACnet
BACnet
protocol
protocol
FanFan
coilcoil
units
units
Split
Split
Multi state objects
Multi state objects
Elevator
Elevator
Air handling unit
Air handling unit
Alarm
Alarm
224
224
Price List 2016
ECPEN15-200.indd 224
99
12/02/15 11:47
VRV Accessories Remote Controllers (supplied loose)
VRV Remote Control Options
Model
Description
Related Fan Coil
Trade Price
BRC1E52A
Premium wired remote controller with full text menu,
Energy features and 7 Day Time Clock
All
£76.00
BRC2E52C
Premium wired controller with simplified outlook
All
£80.00
UK.BRC2E/CHR/POL
Polished chrome simplified controller, recessed in wall
All
£180.00
UK.BRC2E/CHR/BRU
Brushed chrome simplified controller, recessed in wall
All
£180.00
UK.BRC2E/BRA/POL
Polished brass simplified controller, recessed in wall
All
£180.00
BRC3E52C
Simplified remote controller (without heat/cool button)
All
£80.00
UK.BRC3E/CHR/POL
Polished chrome simplified controller, recessed in wall
(without heat/cool button)
All
£180.00
UK.BRC3E/CHR/BRU
Brushed chrome simplified controller, recessed in wall
(without heat/cool button)
All
£180.00
UK.BRC3E/BRA/POL
Polished brass simplified controller, recessed in wall
(without heat/cool button)
All
£180.00
BRP7A51/UK.FB2
Digital input adaptor for Key card and Window switch
contacts with programmable logic
For use with Simplified controllers
£85.00
BRC4C61
Wireless remote controller
FXKQ-MA
£135.00
BRC4C62
Wireless remote controller
FXDQ-M9
£135.00
BRC4C65
Wireless remote controller
FXMQ-P7, FXLQ-P, FXNQ-A, FXDQ-A,
FXSQ-A, FXMQ-MB
£152.00
BRC7C58
Wireless remote controller
FXUQ-A
£152.00
BRC7C52
Wireless remote controller
FXCQ-A
£152.00
BRC7E618
Wireless remote controller
FXAQ-P
£135.00
BRC7F530W
Wireless remote controller for White Ceiling Decoration Panel
FXZQ-A + BYFQ60CW
£152.00
BRC7F530S
Wireless remote controller for Silver Ceiling Decoration Panel
FXZQ-A + BYFQ60CS
£152.00
BRC7EB530W
Wireless remote for Fully Flat Cassette Old Style Decoration Panel
FXZQ-A + BYFQ60B3
£152.00
BRC7FA532F
Wireless remote controller
FXFQ-A
£152.00
BRC7G53
Wireless remote controller
FXHQ-A
£152.00
VRV
Hard Wired Controllers
Infra Red controllers
100
Residential, Commercial and Industrial
VRV Accessories Control and BMS Interfaces (supplied separately)
VRV Control and BMS Interfaces
KRP4A53
RTD-NET
RTD-10
RTD-20
RTD-HO
KLIC-DI
System
Unit/Group
Unit/Group
Unit/Group
Unit/Group
Unit/Group
Unit/Group
System
System
System
Control Protocol
Daikin
Daikin
Modbus
Modbus
-
Modbus
Modbus
KNX
LONWorks
BACnet
Modbus
0-10 Volt control
-
-
-
-
4
4
-
-
-
-
-
4
4
-
-
4
4
-
-
-
-
-
On/Off
4
4
4
4
4
4
4
4
4
4
4
SetPoint
Resistance control
DMS504B51 DMS502A51
EKMBDXA
VRV
KRP2A52
Interface Method
Control Functions
4
4
4
4
4
4
4
4
4
4
4
Operating Mode
-
-
4
4
4
4
4
4
4
4
4
Fan Speed
-
-
4
4
4
4
4
4
4
4
4
Louver Setting
-
-
4
4
4
4
4
4
-
4
4
VAM Damper control
-
-
4
4
4
4
-
-
-
-
-
Control Prohibit / Restrict settings
-
-
4
4
4
4
4
-
4
4
4
Temperature SetPoint Limits
-
-
4
4
-
4
4
4
-
-
4
Scene Creation
-
-
-
-
-
-
-
4
-
-
-
Monitoring Functions
4
4
4
4
-
4
4
4
4
4
4
Temperature Set Point
-
-
4
4
-
4
4
4
4
4
4
Operating Mode
-
-
4
4
-
4
4
4
4
4
4
Thermostat On
-
-
4
4
4
4
4
-
4
4
4
Fan Operation
-
-
4
4
-
4
4
4
4
4
4
Louvre Position
-
-
4
4
-
4
4
4
-
4
4
4
4
4
4
4
4
4
4
4
4
4
Fault Code
-
-
4
4
-
4
4
4
4
4
4
Remote Controller temperature
-
-
4
4
-
4
4
-
4
4
4
Remote Controller Mode
-
-
4
4
-
4
4
-
-
-
-
Number of Units
-
-
4
4
-
4
4
-
-
-
-
Return Air Temperature (Average/Min/Max)
-
-
4
4
-
4
4
-
4
4
-
Coil In/Out temperature
-
-
4
4
-
4
4
-
-
-
-
Filter Alarm
-
-
4
4
-
4
4
4
4
4
4
Defrost Operation
-
-
4
4
4
4
4
-
-
-
4
Temperature Set Back
-
-
-
-
-
4
4
-
-
-
-
Temperature Setpoint Limitation
-
-
-
4
4
4
4
-
-
-
-
Key Card + Window Contact
-
-
-
-
-
4
4
-
-
-
-
Heating Interlock
-
-
-
4
4
-
-
-
-
-
-
Run / Standby
-
-
-
-
4
-
-
-
-
-
-
Interface
KRP2A52
KRP4A53
RTD-NET
RTD-10
RTD-20
RTD-HO
KLIC-DI
DMS504B51
DMS502A51
EKMBDXA
Trade Price
£177.00
£67.00
£165.00
£210.00
£226.00
£210.00
£185.00
£1,173.00
£3,773.00
£1,980.00
Mounting Box
(FXFQ, FXCQ, FXZQ, FXUQ, FXHQ, FXDQ, FXAQ)
UK.FB2
UK.FB2
UK.FB2
UK.FB2
UK.FB2
UK.FB2
-
-
-
-
Trade Price
On/Off
Fault
Integral Functions (BMS system not req’d)
Prices
Associated Items
£25.00
£25.00
£25.00
£25.00
£25.00
£25.00
-
-
-
-
Expansion PCB for additional unit connection
-
-
-
-
-
-
-
-
DAM411B51
-
Trade Price
-
-
-
-
-
-
-
-
£879.00
Pulse input PCB for KWh meter input
-
-
-
-
-
-
-
-
DAM412B51
-
Trade Price
-
-
-
-
-
-
-
-
£468.00
-
Price List 2016
101
VRV Accessories RTD-20 Control Panels
Control Panels have been developed to allow easy installation of the RTD-20 into end-user premises.
A typical application would require 1 RTD-20 per zone within a building. The control panels are
pre-configured for up-to 8 different zones, making installation and wiring much simpler for the installer.
VRV
Model
Description
Trade Price
RTD-20 Control Panels are
sold at listed price.
No discounts will apply.
UK.RTD-20/ENCH
Enclosure for RTD20 x 1
£305.54
UK.ENC/RTD-20X2
Enclosure for RTD-20 x 2
£765.54
UK.ENC/RTD-20X3
Enclosure for RTD-20 x 3
£1,010.81
UK.ENC/RTD-20X4
Enclosure for RTD-20 x 4
£1,256.08
UK.ENC/RTD-20X5
Enclosure for RTD-20 x 5
£1,576.35
UK.ENC/RTD-20X6
Enclosure for RTD-20 x 6
£1,826.62
UK.ENC/RTD-20X7
Enclosure for RTD-20 x 7
£2,071.89
UK.ENC/RTD-20X8
Enclosure for RTD-20 x 8
£2,317.16
Accessories for RTD-20 Control Panels
Description
Trade Price
UK.RTD-EXTSEN
Air Curtain External Sensor
£19.95
UK.RTD-INTSEN
Internal Sensor for RTD Device
£12.50
UK.RTD-CABLE
RS485 Cable for wiring RTD Devices 100m Roll
£60.90
UK.RTD-PIR/7.5M
PIR Sensor & 7.5M Cable Assy
£54.00
UK.RTD-PIR/15.0M
7.5m Extension Cable for UK.RTD-PIR/7.5M
£21.45
VRV Accessories Centralised Control Solutions
Model
102
Description
Trade Price
DCS601C51
Intelligent touch controller for up to 64 fan coil units
£1,641.00
KJB411A
Recessed Fixing box for I-Touch controller
£69.00
DCS302A52
Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager
£104.00
DTA103A51
Adaptor PCB for on/off control of external device from I-Touch controller and I-Touch manager
£305.00
UK.IC Config
I-Touch controller - off site configuration charge (please contact your sales office for info/prices)
POA
Residential, Commercial and Industrial
Model
Description
Trade Price
DCM601A51
I-Touch manager central touch screen controller, with integral web server
and email function
£2,262.00
DCM601A52
I-Touch manager Expansion Module for up to 64 fan coil units and 4 x kWh Meters
£707.00
DCM002A51
Proportional Power Distribution add-on for I-Touch manager.
Provides ability for tenant billing
£1,761.00
DCM007A51
Open protocol software for BMS Integration
£936.00
DCM008A51
Energy Navigator Software for I-Touch manager.
For on screen energy monitoring
£2,742.00
DCM009A51
BAC Net protocol for 3rd party products
£1,203.00
DCS302A52
Adaptor PCB for external on/off control of I-Touch controller and I-Touch Manager
£104.00
DTA103A51
Adaptor PCB for on/off control of external device from I-Touch controller
and I-Touch manager
£305.00
WAGO Interface
System
Modular interface system for connection to 3rd Party devices such as lights, pumps,
PIR sensors, access card readers, etc. Enables the iTM to control external devices and
provide customised interlocks for automation and energy saving logic
POA
UK.IMAN/CONFIG1
I-Manager Off site configuration per FCU
£7.00
UK.IMAN/CONFIG2
I-Manager Off site configuration & graphical layout per FCU.
(Allow 4 weeks from order to delivery)
£10.00
UK.FS1
On site commissioning for PPD or Energy Navigator Software
£585.00
UK.IMAN/SITE TRAIN
On Site customer training for I Touch Manager System
£585.00
Price List 2016
103
VRV
VRV Accessories Centralised Control Solutions
NEW
VRV
VRV Accessories Centralised Control Solutions
Control of air conditioning within a retail
environment produces its own set of challenges.
The controls are often ‘hidden’ to prevent
unauthorised access. This can result in equipment
being left continuously operating, heating and
cooling clashing and extremes of set point.
Tabl
e
t
Hardware
Model
Description
Trade Price
DCC601A51
Intelligent Tab Controller, with I/O module
and power supply unit
£590.00
Z380C
Tablet for optional Wi-Fi based local control
£245.00
4G-N12
Optional 3G router for Wi-Fi /
web based control *
£225.00
This can lead to user comfort complaints and
excessive energy consumption.
Frequently there is only one user who knows how to
access the controls, and the maintenance company
has no off site access to make adjustments.
The solution to these issues is the Daikin
Intelligent Tablet Controller.
Features and benefits:
>
>
>
>
>
>
>
>
Control of up to 32 indoor units (groups)
Control of VRV, SkyAir, Splits, Air curtains & VAM units
Intuitive local control via App based interface
Control of all unit functions plus scheduling and set point
restrictions integral to system
Optional web based cloud control for off-site access
Optional web based energy management software to
automatically reduce wasted energy
Optional multi-site control to facility benchmarking and permit
control to be ‘pushed through’ to multiple sites in one operation
Modular system – sites can be added to the controls package as
they become available.
Local solution
*Supply of a suitable activated Sim and maintenance of the Sim contract is required by the installer.
Service packages (annual fee)
Description
Trade Price **
Remote monitoring and control software for intelligent Tab Controller.
Provides web access to intelligent Tab Controller.
Energy performance software for intelligent Tab Controller.
Provides energy saving control features.
Multi-site management software for intelligent Tab Controller.
Provides Benchmarking and Trending plus multi-site control.
Business package software for LCC.
Provides all features of Remote monitoring & control software,
Energy performance software & Multi-site management software.
POA
** First year subscription included in price of hardware.
Annual renewal carried out on-line at listed price - not subject to discount.
Online control from any device
Alarm
Window
contact
Daikin supplied screen
(optional) (for local control)
Z380C-1A023A
Owner
Pulse input
or
Digital input
intelligent Tablet Controller
wireless network
Daikin supplied router
(optional) 4G-N12
Installer/
technical manager
Tabl
et
DCC601A51
Power supply CPU module
Daikin network
104
Via internet
or
Via 3G/4G connection
I/O module
Split,
,
HRV, ventilation,
air curtains
Residential, Commercial and Industrial
,
From one to ∞ sites
POA
POA
POA
NEW
VRV Accessories VRV & SkyAir Wi-Fi adapter
Wi-Fi adapter
VRV
For use with VRV & SkyAir
Features:
Basic Operations
> On/Off
> Operation mode
> Set point & room temperature
> Fan speed
> Air flow direction
> Time clocking
Wi-Fi adapter
A delay off timer to automatically stop the air conditioning after
a fixed number of hours run can be set. In addition multiple time
clock schedules can be set. Both of these features can reduce
energy wastage.
Provide your customers with enhanced control of their air
conditioning systems, with the Daikin Wi-Fi adapter and free
downloadable App for smart phone or tablet.
Occupied (Setback) and unoccupied (Home Leave) can be
separately enabled to ensure minimum comfort levels are
maintained when the property is empty.
Benefits:
In the event of an operational issue, the error & associated code
will be displayed, to aid in the reinstatement of your system.
Manually and automatically control the environment using your
smart phone.
Individual control of each room as well as control of the property
as a whole is available via the group control function.
From switching between heat and cooling, setting the required
temperature and fan speed, setting minimum comfort levels and
time clocking your air conditioning, the climate will be maintained
to meet your requirements.
An unlimited number of rooms and multiple properties can be
controlled by a single account.
> M
ultiple users – Each user can be given their own account and
allocated unit(s). Users can even share access to the same unit(s).
> P
hone not available – Control is also available via a dedicated
web site using a web browser on your tablet or PC.
Indication of the ambient temperature and a weather forecast for
the locale surrounding the property allow the user to adjust the
system settings to meet their requirements.
Model
DKNWSERVER
Description
Wi-Fi adapter to connect to on-line server*
Trade Price
£189.00
*Broadband internet connection, Wi-Fi connection or Mobile data connection required.
*No annual charge is required to access this service.
Price List 2016
105
VRV Accessories Fan Coil Accessories (supplied separately)
VRV
Model
Description
Related Unit
Trade Price
BYCQ140DG
Roundflow cassette decoration panel with self cleaning filter
FXFQ-A
£310.00
BYCQ140DW
Roundflow cassette decoration panel - white with white louvres
FXFQ-A
£160.00
BYFQ60CS
Fully Flat Cassette Decoration Panel - Silver
FXZQ-A
£198.00
BYFQ60B3
Fully Flat Cassette Decoration Panel - Old Style (FXZQ-MA style)
FXZQ-A
£170.00
KDBHQ55B140
Sealing member for air discharge outlet
FXFQ-A
£90.00
BDBHQ44C60
Sealing member for air discharge outlet - Fully Flat cassette
FXZQ-A
£91.00
KDDQ55C140 1&2
Fresh air intake kit for up to 20% fresh air (Not compatible with self-cleaning
decoration panel)
FXFQ-A
£233.00
KDDQ50A140
Fresh air intake kit for up to 20% fresh air
FXHQ-A
£158.00
UK.RC1
1x200mm Return air spigot
FXSQ15 / 20 / 25 / 32 A
£70.00
UK.RC2
2x200mm Return air spigot
FXSQ 40 / 50 A
£79.00
UK.RC3
2x200mm Return air spigot
FXSQ 63 / 80 A
£86.00
UK.RC3A
3x200mm Return air spigot
FXSQ 63 / 80 A
£93.00
UK.RC4
4x200mm Return air spigot
FXSQ 100 / 125 / 140 A
£116.00
UK.SF1
1x200mm Supply air spigot
FXSQ15 / 20 / 25 / 32 A
£63.00
UK.SF2
2x200mm Supply air spigot
FXSQ 40 / 50 A
£72.00
UK.SF3
2x200mm Supply air spigot
FXSQ 63 / 80 A
£79.00
UK.SF3A
3x200mm Supply air spigot
FXSQ 63 / 80 A
£84.00
UK.SF4
4x200mm Supply air spigot
FXSQ 100 / 125 / 140 A
£104.00
UK.FF7/P
Filter frame and filter
FXMQ100 to 125
£118.00
UK.FF8
Filter frame and filter
FXMQ200 to 250
£146.00
KRCS01-4
Remote room mounted temperature sensor
FXFQ-A, FXZQ-A, FXQC-A, FXHQ-A,
FXUQ-A, FXSQ-P, FXMQ-P7, FXDQ-A
£42.00
KRCS01-1
Remote room mounted temperature sensor
FXKQ-MA, FXDQ-P9, FXMQ-MA,
FXAQ-P, FXLQ-P, FXNQ-P
£46.00
K.RSS
Wireless room mounted temperature sensor and receiver
All
£89.00
RS-SE
Service and Configuration Tool for K.RSS
All
£93.00
Condensing Unit Accessories (supplied separately)
Model
Description
Related Unit
Trade Price
BRP2A81
Adaptor PCB for Heat Cool selection terminals
RYYQ-T
£102.00
EBRP2B
Adaptor PCB for Heat Cool selection terminals
RXYSQ4-6T7V
£52.00
EKCHSC
Adaptor Cable for Heat Cool selection terminals
RXYSQ4-6T7Y
£16.00
KJB111A
Fixing box for EBRP2B & EKCHSC
RXYSQ4-6T
£17.00
KRC19-26
Cool/Heat selector switch for use with BRP2A81, EBRP2B or EKCHSC
RYYQ-T, BS1Q-A & RXYSQ4-6T
£32.00
EKPCCAB1
VRV Configurator Software Connection Cable. Software available from Daikin Extranet RYYQ-T, REYQ-T, RXYSQ-T & RXYSCQ-T
£176.00
K.CGL
Condensing Unit Guard size 100-140 including RXYSQ
£354.00
Strip & Rebuild of Condensing Units
VRV Condensing Units stripped down for delivery to site where lifting into position is
difficult with traditional methods. Units are rebuilt on site by Daikin UK Engineers and
fully retested.
POA
106
Residential, Commercial and Industrial
VRV Accessories VRV Refrigerant Leak Detection System
Refrigerant leak detection systems can be required by the Safety of Building Occupants , BS-EN378.
Daikin has a solution that can help meet requirements for leak detection within enclosed spaces.
1) The standard BS-EN378 requires that systems containing R410A refrigerant
gas such as VRV, meet the requirements regarding maximum system refrigerant
volumes that could leak within Hotel Bedroom or other similar Category Class A
spaces. If these limitations are exceeded there must be an alarm system installed
within each room where this limit is not met. The alarm system must alert the
occupier through both audible and visual indication, and must also alert building
staff such as supervisors, night porters etc. There is no specific requirement for the
alarm system to be linked to the refrigerant system to pump down or stop the
operation, although this can be configured if required by the client.
3
3
7
Not
installed
by door
7
7
7
Not installed near
bathroom
Not
installed
behind
cupboards
7
Not installed near
mirrors
Refrigerant leak
detector position
It is recommended that guidance on the selection and installation of these
systems is obtained from your local Daikin UK sales office.
Model
Not
installed
near
windows
Bed
150mm above
floor level
Description
Related Unit
Trade Price
UK.RDEM-Wht
White single gang room based refrigerant gas detector. C/W power supply unit and
terminals for connection to alarm network or VRV fan coil to force system shut down
All
£276.00
UK.RDEM-Wht/
Curve
Curved white single gang room based refrigerant gas detector. C/W power supply unit
and terminals for connection to alarm network or VRV fan coil to force system shut down
All
£296.00
UK.RDEM-St/St
Stainless steel single gang room based refrigerant gas detector. C/W power supply unit
and terminals for connection to alarm network or VRV fan coil to force system shut down
All
£296.00
UK.IMEC-RAD-32
Network alarm hub for connection of up to 32 room alarms c/w web page configuration
screen. Hub can be connected in a pyramid formation for connection to a central alarm
indicator panel (UK.IAMC)
All
£1,775.00
UK.IMEC-RAD-64
Network alarm hub for connection of up to 64 room alarms c/w web page configuration
screen. Hub can be connected in a pyramid formation for connection to a central alarm
indicator panel (UK.IAMC)
All
£2,450.00
Description
Related Unit
Trade Price
UK.IAM1
Room based refrigerant gas detector with remote room mounted stainless steel facia
plate. Provides local audible and visual alarm notification. Terminals for connection to
alarm network and optional connection to VRV Fan coil to force system shut down
All
£279.00
UK.IAM2
Network alarm hub for connection of up to 16 room alarms. Hub can be connected
in a pyramid formation of 16 groups back to a single unit for connection to a central
alarm indicator panel (UK.IAMC)
All
£550.00
UK.IAMC
Alarm buzzer and lamp panel for mounting in a central building supervisor location
All
£388.00
Cross connection between the two different ranges of refrigerant leak detectors is not permissible.
Model
Price List 2016
107
VRV
Refrigerant Leak Detection Alarm
VRV Accessories VRV Cloud
Energy Assessment and Reporting
VRV Cloud is Daikin’s unique energy usage assessment, optimisation,
control and reporting tool.
VRV
System operational data can also be reported for a complete picture
of system performance.
Energy assessment
Individual VRV system or whole site energy consumption can
be accessed and viewed in a graphical form. The data can be
viewed as an hourly, daily, monthly or annual graph. The energy
consumption can be plotted against the outdoor air temperature
or against a target consumption (which can be manually entered or
automatically generated).
Energy optimisation
A target annual energy consumption limit can be set and the
system will reduce operational output to meet the target. The
target can either be manual set or automatically set via a simple
slide bar – calibrated by user comfort level vs energy saving level.
Control
Access to the on-site touch screen controller is possible remotely.
This gives the ability to change operational settings without having
to attend site.
Reporting
Indoor and outdoor unit operational data can be viewed in tabular
form. All data, energy usage and operational, can be extracted as a
CSV file for incorporation within your own reports.
Features and benefits:
>
>
>
>
Unique Daikin automatic energy optimisation tool
Graphical reporting of energy usage
Remote access to site operational settings
Reduction to energy consumption can be weighed
vs user comfort
> All data available for incorporation into your own reports.
For more information, please contact your
Daikin sales engineer.
108
Residential, Commercial and Industrial
Daikin UK Price List 2016
Ventilation
VENTILATION
VAM-FC110
VKM-GB(M)112
For larger ventilation capacities from 2,000m3/hr to 15,000m3/hr see
the new Daikin modular AHU on pages 186-188 of the Applied section.
Scottish
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Ventilation
Achieving high indoor air quality for building
occupants is an essential factor in HVAC design,
especially in light of building regulations and the
high levels of air tightness within modern buildings.
VAM-FC
Total Heat Exchanger
Our popular range of Total Heat Exchangers (VAM) have been
updated and are fully compliant with the new lot 6 Ecodesign
requirements and rated under the EN 308* testing standard.
VAM units recover waste energy from the exhaust airstream
to minimise running costs and reduce the carbon footprint
of the building.
Daikin offers a range of options that enables control of fresh air
into commercial and residential spaces. For flow rates of up to
0.556m3/s, our VAM / VKM range of heat recovery ventilation
products can efficiently deliver controlled fresh air to meet your
design priorities. For larger fresh air requirements, please see our
Applied section for our range of packaged air handling units
(See page 186-188 for our Modular AHU range).
Eliminates up to 73%
of the additional heating
& cooling loads caused by
introducing fresh air.
VENTILATION
VAM-FC
Total Heat Exchanger
VAM150FC
Dimensions
Height
Width
Depth
mm
mm
mm
Weight
kg
Duct Connection Diameter
mm
Air Flow Rate
Ultra-High
m3/hr
High
m3/hr
Low
m3/hr
Ultra-High
m3/sec
High
m3/sec
Low
m3/sec
External Static
Ultra-High
Pa
Pressure
High
Pa
Low
Pa
Sound Pressure
Ultra-High
dBA
Level (Heat
High
dBA
Exchange Mode) Low
dBA
Electrical Details Power Supply
V / Hz / Phase
Running Current A
Max Fuse Size
A
Trade Unit Price
VAM250FC
VAM350FC
285
776
525
24
VAM500FC
301
828
816
33
VAM650FC
VAM800FC
VAM1000FC
VAM1500FC
364
1004
868
VAM2000FC
726
1514
54
250
800
725
665
0.222
0.201
0.185
109
94
78
36.0
34.5
31.0
1160
63
250
1000
950
820
0.278
0.264
0.228
147
135
100
36.0
35.0
31.0
868
128
350
1500
1350
1230
0.417
0.375
0.342
116
97
80
39.5
38.0
34.0
1156
145
350
2000
1880
1500
0.556
0.522
0.417
132
118
77
40.0
38.0
35.0
2.5
15
3.0
15
5.0
15
5.0
15
100
150
140
105
0.042
0.039
0.029
90
87
40
27
26
20.5
150
250
230
155
0.069
0.064
0.043
70
63
25
28.0
26.0
21.0
150
350
320
210
0.097
0.089
0.058
103
93
51
32.0
31.5
23.5
200
500
410
310
0.139
0.114
0.086
83
57
35
33.0
31.5
24.5
0.9
15
0.9
15
0.9
15
1.3
15
51
200
650
545
450
0.181
0.151
0.125
100
73
49
34.5
33.0
27.0
230 / 50 / 1
1.6
15
£430.00
£514.00
£681.00
£872.00
£1,067.00
£1,257.00
£1,441.00
£2,201.00
£2,871.00
VAM350FB
VAM500FB
VAM650FB
VAM800FB
VAM1000FB
VAM1500FB
VAM2000FB
* For full details of specifications relating to EN308 please see the technical data book
Optional Accessory Compatibility
VAM150FA
Inlet Heater Battery+
Air Filter
VH1B
-
VAM250FA
VH2B
-
VH3B
EKAFV50F*
EKAFV80F*
VH4B or VH4/AB
EKAFV100F*
VH5B
2 x EKAFV100F*
=+ Heater battery does NOT require PCB adaptor to connect to VAM
* available in Medium M6, Fine F7 and Fine F8. Only one filter is required to cover the whole of one side of the heat exchanger, even if the heat exchanger has two sections.
Optional Inlet Heater Battery
Capacity
Duct Diameter
Trade Unit Price
kW
mm
VH1B
VH2B
VH3B
VH4B
VH4/AB
VH5B
1
100
£590.00
1
150
£596.00
1
200
£600.00
1.5
250
£650.00
2.5
250
£644.00
2.5
350
£650.00
Accessories:
Accessory Ref
Description
Trade Price
BRC1E52A
KRP2A52/UK.FB2
RTD-Net/UK.FB2
RTD-20/UK.FB2
BRP4A50
KRP50-2
BRP4A50A
EKAFV50F6
EKAFV50F7
EKAFV50F8
EKAFV80F6
EKAFV80F7
EKAFV80F8
EKAFV100F6
EKAFV100F7
EKAFV100F8
BRYMA65
BRYMA100
BRYMA200
Premium wired remote controller with full text menu, Energy features and 7 Day Time Clock
System adaptor PCB for remote on/off, status indication and temperature setting
Modbus Interface PCB for Sky Air and VRV
Energy control PCB for Sky Air and VRV
PCB Adaptor for VAM-A series connection to 3rd party heater
PCB Adaptor for VAM-A series connection to humidifier
PCB Adaptor for VAM-B Series connection to 3rd party heater or humidifier
Air filter for VAM350 / 500FB : Medium M6
Air filter for VAM350 / 500FB : Fine F7
Air filter for VAM350 / 500FB : Fine F8
Air filter for VAM650 / 800FB : Medium M6
Air filter for VAM650 / 800FB : Fine F8
Air filter for VAM650 / 800FB : Fine F7
Air filter for VAM1000 / 2000FB : Medium M6
Air filter for VAM1000 / 2000FB : Fine F7
Air filter for VAM1000 / 2000FB : Fine F8
CO2 Sensor for VAM350 / 500 / 650
CO2 Sensor for VAM800 / 1000
CO2 Sensor for VAM1500 / 2000
£76.00
£202.00
£190.00
POA
£94.00
£107.00
£118.00
£51.00
£57.00
£62.00
£57.00
£62.00
£68.00
£87.00
£93.00
£98.00
£376.00
£376.00
110
Residential, Commercial and Industrial
£376.00
CO2 sensors for VAM-FC range
minimise running costs, delivering
only the ventilation amounts
required to maintain your indoor
air quality
Notes:
i)Please contact your local sales office
for required options when combined
operation with an air conditioning system
is required
ii)Optional silencers and high efficiency
filters are available. Prices and details on
request
iii)VKM models must be connected as the
slave indoor unit of a standard VRV indoor
unit and share the same BRC1D52 remote
controller and BS-Q box (If connected to
Heat Recovery)
iv)UK.VH-CK VAM EHBX24 conversion kit
cable included
VAM-FC
Weather Proof Enclosures for VAM Total Heat Exchangers
If you need to install a VAM unit outside of a building
then they need to be weatherproofed as they are
designed for installation internally.
We can offer fully weatherproofed housings for the VAM range
which are rated IP46 to make them suitable for outdoor installation.
The VAM units are fitted into the enclosure and delivered to site for
fuss free installation.
Please note:
> T he prices quoted are for the enclosure, fitting of the VAM
into the enclosure and standard delivery. The VAM unit cost
is not included.
VENTILATION
> P
re heaters cannot be used with the VAM weatherproof
enclosures.
Lead time: 6 weeks
Applicable units: All VAM units (not VKM)
VAM250
*Nett Enclosure Price (excluding VAM unit price)
VAM350
VAM500
£780.00
VAM650
VAM800
VAM1000
VAM1500
VAM2000
£900.00
£1,025.00
£1,100.00
* Not subject to standard trade discount.
Please speak to your local sales engineer to discuss your requirements.
Price List 2016
111
VKM-GB(M)
Total Heat Exchanger with DX Cooling & Heating
(and Optional Humidifier)
The Total Heat Exchanger removes additional fresh air loads by heating
and cooling the air to suit the room setpoint. VKM units work with Daikin
VRV indoor units to give a complete air conditioning solution by heating,
cooling, cleansing, humidifying and distributing air within a space.
Eliminates up to 100%
of the additional heating
& cooling loads caused by
introducing fresh air
Total Heat Exchanger with DX Coil (No Humidifier)
VENTILATION
Power input 50Hz
Heat exchange
mode
Fresh air
Cooling
conditioning load Heating
Dimensions
Weight
Temperature Exchange Efficiency
Fan
Air flow rate 50Hz
External static
pressure - 50Hz
Sound pressure
level 50Hz
Heat exchange
mode
Duct connection diameter
Piping
Type
connections
Liquid
Gas
Drain
Nom.
Ultra high
High
Low
Height x Width x Depth
Ultra high / High
Low
Heat exchange
mode
Ultra high
High
Low
Ultra high
High
Low
Ultra high
High
Low
Ultra high
High
Low
OD
OD
kW
kW
kW
kW
kW
mm
kg
%
%
m³/h
m³/h
m³/h
m³/s
m³/s
m³/s
Pa
Pa
Pa
dBA
dBA
dBA
mm
VKM50GB
VKM80GB
VKM100GB
0.270
0.230
0.170
4.71
5.58
387 x 1764 x 832
96
76
77.5
500
500
440
0.139
0.139
0.122
0.330
0.280
0.192
7.46
8.79
0.410
0.365
0.230
9.12
10.69
387 x 1764 x 1214
109
78
79
750
750
640
0.208
0.208
0.178
210
170
140
39.0
37.0
35.0
200
160
110
41.1
39.0
37.0
36.5
250
Flare connection
1/4 (6.4)
1/2 (12.7)
PT3/4 external thread
Inch (mm)
Inch (mm)
Trade Unit Price
114
74
76.5
950
950
820
0.264
0.264
0.228
150
100
70
41.0
£2,089.00
£2,536.00
£3,016.00
VKM50GBM
0.270
0.230
0.170
4.71
5.58
VKM80GBM
0.330
0.280
0.192
7.46
8.79
Natural evaporating type
4.0
0.02 ~ 0.49
VKM100GBM
0.410
0.365
0.230
9.12
10.69
Total Heat Exchanger with DX Coil and Humidification
Power input 50Hz
Heat exchange
mode
Nom.
Ultra high
High
Low
Fresh air
Cooling
conditioning load Heating
Humidifier
System
Amount
Feed water pressure
Elements
Quantity
Dimensions
Height x Width x Depth
Weight
Temperature Exchange Efficiency
Ultra high / High
Low
Fan
Air flow rate Heat exchange
Ultra high
50Hz
mode
High
Low
Ultra high
High
Low
External static
Ultra high
pressure - 50Hz
High
Low
Sound pressure
Heat exchange
Ultra high
level 50Hz
mode
High
Low
Connection duct diameter
Piping
Type
connections
Liquid
OD
Gas
OD
Water supply
Drain
kW
kW
kW
kW
kW
kg/h
MPa
2.7
mm
kg
%
%
m³/h
m³/h
m³/h
m³/s
m³/s
m³/s
Pa
Pa
Pa
dBA
dBA
dBA
mm
387 x 1764 x 832
102
76
77.5
500
500
440
0.139
0.139
0.122
200
150
120
38.0
36.0
34.0
200
5.4
1
120
78
79
750
750
640
0.208
0.208
0.178
205
155
105
40.0
37.5
35.5
125
74
76.5
950
950
820
0.264
0.264
0.228
110
70
60
40.0
38.0
35.5
250
Flare connection
1/4 (6.4)
1/2 (12.7)
1/4 (6.4)
PT3/4 external thread
Inch (mm)
Inch (mm)
Inch (mm)
Trade Unit Price
2
387 x 1764 x 1214
£2,324.00
£2,900.00
£3,245.00
Notes:
i)Options for the VAM FC range are not compatible with the VKM G or VKM GM range
112
Residential, Commercial and Industrial
ii)The humidifier in the VKM GM range operates solely in Heating mode and requires
a third party humidistat to be connected
Daikin UK Price List 2016
Heating
Commercial Heating114
Altherma Flex Product Overview
114
Altherma Flex De-Centralised
115
Altherma Flex Centralised
116
Domestic Heating118
Air-to-Water Heat Pump
119
Hybrid Heat Pump
129
Solar Thermal
135
Underfloor Heating
149
Heat Pump Convector
156
HEATING
Netatmo134
As of the 26th September 2015 certain heating products are subject
to the Energy Labelling Directive. Please go the following website to
download your energy label. www.daikin.co.uk/energylabel
Dedicated Heating Line: 0845 641 9070
Scottish
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
The Daikin Altherma Flex Heat Pump Series
The Daikin Altherma Flex heat pump is ideal
for apartment buildings and community
heating, providing efficient air-to-water heat
pump technology for large residential and
commercial buildings.
The product can be configured
either as a de-centralised
or a centralised system:
HEATING
De-centralised system
The hydroboxes can be located in individual dwellings, such as
apartments or collective housing, to create a de-centralised system. Each indoor unit can be operated independently, providing each
property with individual control of heating, hot water (cooling
optional on 50 & 80 class units).
The indoor hydrobox units are fully equipped with all the required
hydraulic components, so they can be connected easily to the heat
distribution system. Individual dwellings can also be equipped
with separate domestic hot water tanks, which are designed to
stack on top of the indoor units.
Centralised system
Alternatively, the indoor units can be
located together in one central plant area
to create a centralised system suitable
for a wide range of commercial and large
domestic applications.
The centralised indoor units offer modular
system scalability and capacity to meet the
heating demand of the overall building.
114
Residential, Commercial and Industrial
Altherma Flex Communal Heat Pump De-Centralised
Daikin Altherma Flex type is the first heating system for apartments and collective housing that fully
incorporates the use of renewable energy sources, making large residential buildings more environmentally
sustainable by increasing energy efficiency – thus delivering lower running costs and CO2 emissions.
Altherma Flex Outdoor Units EMRQ
Outdoor Units
Capacity
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Seasonal space
heating efficiency**
Domestic hot water
heating**
Refrigerant Circuit
Sound Pressure
Piping Limits
Piping Connections
Nominal Heating
Height x Width x Depth
High
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
Space heating
(Average climate) 55°C
Average climate
Refrigerant Type
Refrigerant Charge
Additional Charge
Maximum Length
Maximum Vertical Rise
Liquid
Discharge
Gas
EMRQ8A
22.4
EMRQ10A
28.0
3.167
78.4
331
3.167
78.4
amps
amps
amps
amps
Class
Efficiency
Class
hwh
Declared load profile
4
7.6
17.1
20
A+
108
A
93
XL
4
9.9
22.1
25
A+
104
A
93
XL
kg
kg
dBA
m
m
mm
mm
mm
10.3
10.6
58
58
9.52
15.9
19.1
100~260
5
£4,765.00
9.52
19.1
22.2
125~325
6
£5,000.00
kW
mm
kg
m3/sec
Pa
Capacity Index Limit
Maximum Number of Connected Indoor Units
Trade Condensing Unit Price
EMRQ12A
33.6
1680 x 1300 x 765
EMRQ14A
39.2
EMRQ16A
44.8
3.500
78.4
3-phase / 400V / 50Hz
4
12.6
22.3
25
A+
103
A
93
XL
R410A
10.8
Refer to Databook
60
100
40
12.7
19.1
28.6
150~390
7
£5,773.00
3.917
78.4
4.000
78.4
4
14.0
32.8
40
A+
106
A
84
XL
4
16.9
33.0
40
A+
103
A
93
XL
11.1
11.1
62
63
12.7
22.2
28.6
175~455
9
£6,806.00
12.7
22.2
28.6
200~520
10
£8,021.00
339
* Nominal running
current stated at
-3°C ambient air
temperature &
75°C leaving water
temperature 100%
connection ratio
** With 100%
connection ratio
combination
Indoor Units (Hydrobox)
Function
Heating Capacity
Cooling capacity
Capacity Index
Dimensions
Empty Weight
Leaving Water Temperature Range
Leaving Water Temperature Range
Drain valve
Water Pump
Expansion Vessel
Material
Colour
Electrical Details
kW
kW
Height x Width x Depth
Heating
Cooling
mm
kg
°C
°C
Nominal ESP Heating
kPa
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
Refrigerant Pipe Sizes
Water Side Pipe Sizes
Sound Pressure Level
Refrigerant
Trade Unit Price Hydro Box
amps
amps
amps
amps
mm
dBA
EKHVMRD50AB
EKHVMRD80AB
EKHVMYD50AB
EKHVMYD80AB
Heating & Hot water
Heating, hot water & cooling
5.6
9
5.6
9
n/a
5
8
50
80
50
80
705 x 600 x 695
92
120
25~80
n/a
5~20
Yes
83.7
58.8
7 litres heating
7 litres heating, 2 litres cooling
Precoated sheet metal
Metalic Grey
1-phase / 230V / 50Hz
4
6.5
10.9
6.5
10.9
16.5
20
12.7 Gas, 9.52 Liquid
12.7 Gas, 9.52 Liquid, 15.9 Suction
1" Female
40
42
40
42
R134a Cascade
£2,479.00
£2,560.00
£3,045.00
£3,135.00
Hot Water Cylinders EKHTSU
Accessories:
Domestic hot water cylinder
Type
Max Water Temperature
Height
Width
Depth
Empty Weight
Colour
Material Inside Tank
Material Outside Casing
Piping Connections
All
Insulation
Heat loss / 24 hour Δt 45°C
Energy Efficiency Class
Standing Heat Loss
Storage Volume
Trade Unit Price
Accessories
for hydrobox
RTRNETA3AA (1)
EKRP1AHT
EKRP1HBA
RTD-W
UK.FB2
EKCC-W
EKCLWS
EKRUAHTB (2)
EKBUHA6V3 (3)
EKBUHA6W1 (3)
EKFMAHTB
UK.FSHEAT/
COMMS (4)
°C
mm
mm
mm
kg
inch
mm
W
L
EKHTSU200AC
EKHTSU260AC
Unvented System (Includes EKUHWHT)
75
1335
1610
600
695
70
78
Metallic grey
Stainless Steel
Precoated sheet metal
3/4 "
80
1.2
1.5
B
B
50
63
200
260
£1,113.00
£1,261.00
HEATING
Altherma Flex Indoor Units EKHVMRD / EKHVMYD
Hydrobox & cylinder
shown in combination
* Nominal running
current stated at
-3°C ambient air
temperature &
75°C leaving water
temperature 100%
connection ratio
Description
Trade price
Netatmo thermostat for smartphone
Optional PCB for demand control
Optional PCB for remote alarm monitoring
MODBUS interface for HT hydrobox
Fixing box for RTD-W
Sequence controller
Additional thermistor for sequence controller
Remote user interface
In line back up heater 6kW, 1-phase, 230V
In line back up heater 6kW, 3-phase, 400V
Kit for cylinder standalone installation
Commissioning assistance per hydrobox 1 to 10 hydroboxes
Commissioning assistance per hydrobox 11 to 20 hydroboxes
Commissioning assistance per hydrobox >20 hydroboxes
Daikin full commissioning
£180.00
£104.00
£104.00
£205.00
£25.00
£640.00
£75.00
£157.00
£461.00
£461.00
£277.00
£240.00
£216.00
£192.00
POA
Notes:
Notes:
i) Refnet joint prices can be found on page 97
ii) Commissioning assistance should be included for each hydrobox
iii) DHW cylinder required for hot water function
iv) Supplied with 3 way valve and G3 safety kit (EKUHWHTB)
i) RTRNETA3AA must be ordered alongside EKRP1AHT (1)
ii) EKRUAHTB: 1 included with each hydrobox (2)
iii) EKBUHA6V3(W1): Also requires EKRP1AHT (3)
iv) UK.FSHEAT/COMMS: Commissioning assistance should be included for each hydrobox (4)
Price List 2016
115
Altherma Flex Communal Heat Pump Centralised
Daikin Altherma Flex type is the first centralised heating system for schools, public buildings ,
hotels, gyms & apartments that fully incorporates the use of renewable energy sources, making
large buildings more environmentally sustainable by increasing energy efficiency – thus
delivering lower running costs and CO2 emissions.
Altherma Flex Outdoor Units EMRQ
Outdoor Units
Capacity
Dimensions
Weight
Air Flow Rate
External Static Pressure
Electrical Details
Seasonal space
heating efficiency**
Nominal Heating
Height x Width x Depth
High
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
Space heating
(Average climate) 55°C
Domestic hot water
heating**
Average climate
Refrigerant Circuit
Refrigerant Type
Refrigerant Charge
Additional Charge
Sound Pressure
Piping Limits
Piping Connections
Maximum Length
Maximum Vertical Rise
Liquid
Discharge
Gas
EMRQ8A
EMRQ10A
EMRQ12A
EMRQ14A
EMRQ16A
22.4
28.0
33.6
1680 x 1300 x 765
39.2
44.8
190
78.4
331
190
78.4
235
78.4
240
78.4
amps
amps
amps
amps
Class
Efficiency
Class
hwh
Declared load profile
4
7.6
17.1
20
A+
108
A
93
XL
4
9.9
22.1
25
A+
104
A
93
XL
4
14.0
32.8
40
A+
106
A
84
XL
4
16.9
33.0
40
A+
103
A
93
XL
kg
kg
dBA
m
m
mm
mm
mm
10.3
10.6
11.1
11.1
58
58
62
63
9.52
15.9
19.1
100~260
5
9.52
19.1
22.2
125~325
6
210
78.4
3-phase / 400V / 50Hz
4
12.6
22.3
25
A+
103
A
93
XL
R410A
10.8
Refer to Databook
60
100
40
12.7
19.1
28.6
150~390
7
12.7
22.2
28.6
175~455
9
12.7
22.2
28.6
200~520
10
£4,765.00
£5,000.00
£5,773.00
£6,806.00
£8,021.00
kW
mm
kg
m3/min
Pa
Capacity Index Limit
Maximum Number of Connected Indoor Units
HEATING
Trade Condensing Unit Price
339
* Nominal running
current stated at
-3°C ambient air
temperature &
75°C leaving water
temperature 100%
connection ratio
** With 100%
connection ratio
combination
Altherma Flex Indoor Units EKHBRD
Indoor Unit (Hydrobox)
Function
Heating Capacity
Cooling capacity
Capacity Index
Dimensions
Empty Weight
Leaving Water Temperature Range
Drain valve
Water Pump
Expansion Vessel
Material
Colour
Electrical Details
kW
kW
Height x Width x Depth
EKHBRD
011ADV1
EKHBRD
014ADV1
11
14
100
125
mm
kg
°C
Heating
Refrigerant Pipe Sizes
Water Side Pipe Sizes
Sound Pressure Level
Refrigerant
amps
amps
amps
amps
mm
dBA
Trade Unit Price Hydro Box
EKHBRD
011ADY1
EKHBRD
014ADY1
EKHBRD
016ADY1
14
16
125
140
Heating & Hot water
16
11
n/a
140
100
705 x 600 x 695
145
148
25~80
Yes
92
Power Supply
Starting current
Nominal running Current*
Maximum running current
Fuse Rating
EKHBRD
016ADV1
11.6
22.5
88
85
92
12 litres
Precoated sheet metal
Metalic Grey
1-phase / 230V / 50Hz
4
15.1
23.8
25
18.1
23.8
4.3
12.5
88
3-phase / 400V / 50Hz
4
5.6
12.5
16
15.9 Gas, 9.52 Liquid
1” Female
46
43
R134a Cascade
43
45
£2,985.00
£3,038.00
£3,130.00
85
£3,045.00
6.7
12.5
45
46
£3,099.00
£3,192.00
* Nominal running
current stated at
-3°C ambient air
temperature &
75°C leaving water
temperature 100%
connection ratio
Pre Selected Combinations
Heating capacity (1) A7W35
kW
28.0
31.4
42.0
Heating capacity (2) A-3W65
kW
23.9
26.7
34.3
Outdoor unit
Hydroboxes
Demand PCBs
Refnets
Trade Price
1 x EMRQ8
2 x EKHBRD014ACV1
2 x EKRP1AHT
1 x KHRQ22M29T9
£11,085.00
£4,765.00
£6,076.00
£208.00
£36.00
1 x EMRQ10
2 x EKHBRD016ACV1
2 x EKRP1AHT
1 x KHRQ22M29T9
£5,000.00
£6,260.00
£208.00
£36.00
£11,504.00
(1) Heating ambient air temperature 7°C and leaving water temperature 35°C
(2) Heating ambient air temperature -3°C and leaving water temperature 65°C, capacity stated net of 1 defrost cycle per hour
Notes:
i) Refnet joints can be found on page 97
ii) Commissioning assistance should be included per hydrobox
116
Residential, Commercial and Industrial
iii) DHW cylinder required for hot water function
iv) See page 115 for accessories
1 x EMRQ12
3 x EKHBRD014ACV1
3 x EKRP1AHT
1 x KHRQ22M64H
£15,338.00
47.0
38.7
£5,773.00
£9,114.00
£312.00
£139.00
1 x EMRQ14
3 x EKHBRD016ACV1
3 x EKRP1AHT
1 x KHRQ22M64H
£16,647.00
£6,806.00
£9,390.00
£312.00
£139.00
HEATING
*
Daikin Heating Systems
HEATING
As a leading heating supplier, Daikin’s product
portfolio comprises a wide range of highly energy
efficient renewable energy systems, providing the right
heating solution for any application and requirement.
Daikin Altherma air-to-water heat pump is a renewable energy
heating and hot water solution, ideally suited for the UK
housing market. Using renewable air as a heat source and heat
pump technology with Daikin’s advanced inverter compressor
technology, Daikin Altherma delivers high seasonal efficiencies,
low running costs and reduced carbon emissions compared with
traditional systems. Launched in 2006 with over 250,000 installed
across Europe, Daikin Altherma is the leading air-to-water
heat pump.
Daikin Altherma offers the most comprehensive and flexible range
of air-to-water heat pumps in the market today, suitable for houses,
flats and both new build and refurbishment projects. The range
is available in Low Temperature (Split and Monobloc) and High
Temperature. Daikin Altherma High Temperature is an industry
first system that can deliver water temperatures of up to 80°C,
providing an ideal solution for boiler replacement in harder to
treat properties.
The majority of Daikin Altherma air-to-water heat pumps* are
certified by the Microgeneration Certification Scheme (MCS) and
the Daikin solar thermal collectors have Solar Keymark approval and
therefore are eligible for the domestic RHI. Please check the MCS
website for the latest list of accredited Daikin Altherma air-to-water
heat pumps.
Daikin is at the forefront of the drive for energy efficient heat pump
technology, recognising that heat pumps and the use of renewable
energy from the surrounding air is the answer to meet the future
challenges of energy efficiency and carbon reduction targets.
Daikin renewable energy solutions provide a real alternative to
current and future problems associated with conventional heating
systems such as increasing primary energy costs and unacceptably
high environmental impact.
Daikin solar thermal systems can be combined with Daikin
Altherma to provide a fully integrated renewable energy solution.
Daikin Altherma and Daikin solar thermal systems are recognised
renewable energy solutions that can reduce hot water energy costs
by up to 60% compared with traditional fossil fuel systems.
* Except Daikin Altherma Flex Type
118
Residential, Commercial and Industrial
MCS HP0006
011-7S1016 F
MCS scheme
Solar Keymark
HEATING
Air-to-Water Heat Pump
Daikin Altherma a ir-to-water heat pump is available in the
following models:
Daikin Altherma Low Temperature Split 4-16kW
Daikin Altherma Low Temperature Monobloc 5-16kW
> L atest inverter technology, high seasonal efficiencies and low
running costs
> A
ll key hydraulics built-in, e.g. expansion vessel and
circulation pump
> Guaranteed operation down to -25°C
> Sealed refrigerant circuit with no F-gas needed for installation
> Easy to use back lit controller
> C
ompact wall-hung indoor unit with front access for easy
maintenance
> F lexible siting with indoor unit and small outdoor unit which
can be sited up to 50m away
Daikin Altherma High Temperature 11-16kW
> Providing flow temperatures up to 80°C
Daikin Altherma Flex Type 22.4-44.8kW
*
> For commercial heating applications
* Except Daikin Altherma Flex Type
Price List 2016
119
Single Phase ERLQ-CV3
Low Temperature Split Heat Pump (outdoor)
Outdoor Units
Single Phase
Description
Trade Unit Price
Dimensions
Weight
Nominal capacity
Nominal input
COP
Seasonal space
heating efficiency*
Sound pressure / power level
Refrigerant charge
Piping connections
Heating (a/b)
Cooling
Heating (a/b)
Cooling
Heating (a/b)
Space heating
(Average climate) 35°C
Cooling
Heating
Cooling
Hot water
Heating
Cooling
R-410A
Liquid
Gas
Max piping length OU to IU
Power supply
Recommended fuses
HEATING
ERLQ006CV3
ERLQ008CV3
ERLQ011CV3
ERLQ014CV3
ERLQ016CV3
4kW,
1-phase, 230V
6kW,
1-phase, 230V
8kW,
1-phase, 230V
11kW,
1-phase, 230V
14kW,
1-phase, 230V
16kW,
1-phase, 230V
£1,106.00
£1,481.00
£2,297.00
£2,647.00
£2,894.00
£1,084.00
Height x Width x Depth
Space heating
(Average climate) 55°C
EER
Operation range
ERLQ004CV3
mm
kg
kW
kW
kW
kW
Class
Efficiency
SCOP
Class
Efficiency
SCOP
°C
°C
°C
dBA
dBA
kg
inches
inches
m
735 x 832 x 307
54
4.4 / 4.2
4.17
0.87 / 1.85
1.8
5.04 / 2.27
A++
178
4.52
A++
125
3.20
2.32
56
6.0 / 5.12
4.84
1.27 / 2.31
2.07
4.74 / 2.22
A++
169
4.29
A++
126
3.22
2.34
-25~25
10~43
-25~35
48 / 61
49 / 63
1.6
1/4
5/8
30
48 / 61
48 / 63
1.45
1345 x 900 x 320
56
7.4 / 6.13
5.36
1.66 / 2.89
2.34
4.45 / 2.12
A++
171
4.34
A++
126
3.22
2.29
11.2 / 9.6
11.72
2.43 / 4.57
4.31
4.60 / 2.1
A++
156
3.98
A+
120
3.09
2.72
49 / 62
50 / 63
1.6
51 / 64
50 / 64
113
14.5 / 10.8
12.55
3.37 / 5.19
5.08
4.30 / 2.08
A++
153
3.90
A+
123
3.16
2.47
-25~35
10~46
-20~35
51 / 64
52 / 66
3.4
3/8
5/8
50
16.0 / 10.9
13.12
3.76 / 5.22
5.73
4.25 / 2.09
A+
149
3.80
A+
119
3.06
2.29
52 / 66
54 / 69
1-phase / 230V / 50Hz
A
20
40
Three Phase ERLQ-CW1
Low Temperature Split Heat Pump (outdoor)
Outdoor Units
3 Phase
Description
Trade Unit Price
Dimensions
Weight
Nominal capacity
Nominal input
COP
Seasonal space
heating efficiency*
Height x Width x Depth
Heating (a/b)
Cooling
Heating (a/b)
Cooling
Heating (a/b)
Space heating
(Average climate) 35°C
Space heating
(Average climate) 55°C
EER
Operation range
Sound pressure /
power level
Refrigerant charge
Piping connections
Cooling
Heating
Cooling
Hot water
Heating
Cooling
R-410A
Liquid
Gas
Max piping length OU to IU
Power supply
Recommended fuses
mm
kg
kW
kW
kW
kW
Class
Efficiency
SCOP
Class
Efficiency
SCOP
°C
°C
°C
dBA
dBA
kg
inches
inches
m
ERLQ011CW1
ERLQ014CW1
ERLQ016CW1
11kW, 3-phase, 400V
14kW, 3-phase, 400V
16kW, 3-phase, 400V
£2,521.00
£2,906.00
1345 x 900 x 320
113
14.5 / 10.8
12.55
3.37 / 5.19
5.08
4.30 / 2.08
A++
153
3.90
A+
123
3.16
2.47
-25~35
10~46
-20~35
51 / 64
52 / 66
3.4
3/8
5/8
50
3-phase / 400V / 50Hz
20
£3,177.00
11.2 / 9.6
11.72
2.43 / 4.57
4.31
4.60 / 2.1
A++
156
3.98
A+
120
3.09
2.72
51 / 64
50 / 64
A
16.0 / 10.9
13.12
3.76 / 5.22
5.73
4.25 / 2.09
A+
149
3.80
A+
119
3.06
2.29
52 / 66
54 / 69
* When combined with matching indoor unit
Nominal capacity and nominal input tested according to EN 14511 at the following conditions:
Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)
Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)
Sound pressure level measured at 1m from the unit
Features:
Notes:
>This split system consists of an outdoor unit and an indoor hydrobox that can be connected to all
standard low temperature radiators and underfloor heating systems
> All models have extra features to withstand severe winter conditions
i)Some units are available on special
request with Blygold treatment to
offer additional protection in coastal
environments. Please contact your local
sales office for further information
120
Residential, Commercial and Industrial
Heating Only EHBH
Low Temperature Split Hydrobox (wall hung)
Indoor Unit (wall hung)
Single Phase
User interface (must be ordered)
Description
Combined Trade Unit Price
Function
Dimensions
HxWxD
Leaving water
Heating
temperature range Cooling
Pump
No. of speeds
Expansion vessel volume
Water connections
Back-up heater
3kW 1ph 230V
fuse rating
6kW 1ph 230V
6kW 3ph 400V
9kW 3ph 400V
Single phase / 3 Phase*
EHBH04CB3V
EHBH08CB3V
EHBH11CB3V
EHBH16CB3V
EHBH08CB9W
EHBH11CB9W
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
For ERLQ004CV3
For ERLQ006008CV3
For ERLQ011CV3
For ERLQ014016CV3
For ERLQ006008CV3
For ERLQ011CV3/
W1
For ERLQ014016CV3/W1
£1,236.00
Heating Only
£1,261.00
Heating Only
£1,715.00
Heating Only
£1,715.00
Heating Only
890 x 480 x 344 / 381
15 ~ 55
Inverter controlled
10
1 1/4” (female)
16
£1,272.00
Heating Only
£1,831.00
Heating Only
£1,831.00
Heating Only
mm
°C
°C
litres
Inch
A
A
A
A
-
EHBH16CB9W
32**
10**
16**
Heating and Cooling EHBX
Indoor Unit (wall hung)
Single Phase
Single phase / 3 Phase*
EHBX08CB3V
EHBX11CB3V
EHBX16CB3V
EHBX08CB9W
EHBX11CB9W
User interface (must be ordered)
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
EKRUCBL2
Drain pan kit (must be ordered)
EKHBDPC2
EKHBDPC2
EKHBDPC2
EKHBDPC2
EKHBDPC2
EKHBDPC2
EKHBDPC2
For ERLQ004CV3
For ERLQ006008CV3
For ERLQ011CV3
For ERLQ014016CV3
For ERLQ006008CV3
For ERLQ011CV3/
W1
For ERLQ014016CV3/W1
£1,447.00
Reversible
£1,476.00
Reversible
£1,982.00
Reversible
£1,982.00
Reversible
890 x 480 x 344 / 381
15 ~ 55
5 ~ 22
Inverter controlled
10
1 1/4” (female)
16
£1,493.00
Reversible
£2,074.00
Reversible
£2,074.00
Reversible
Description
Combined Trade Unit Price
Function
Dimensions
Leaving water
Heating
temperature range Cooling
Pump
No. of speeds
Expansion vessel volume
Water connections
Back-up heater
3kW 1ph 230V
fuse rating
6kW 1ph 230V
6kW 3ph 400V
9kW 3ph 400V
mm
°C
°C
litres
Inch
A
A
A
A
-
32**
10**
16**
Accessories:
Notes:
Accessory Ref
Description
Trade Price
EKRUCBL2
EKRUCBS
RTRNETA3AA
EKPCCAB3
EKRSC1
KRCS01-1
EKRP1HBA
User interface
Optional simplified room thermostat
Netatmo thermostat for smartphone
PC cable – to upload field settings from PC to unit or spare controller
Optional remote outdoor temperature sensor (cable not supplied)
Optional remote indoor temperature sensor
Optional PCB kit for remote alarm monitoring, run and fault indication,
solar interlock for heat pump and bivalent operation
U-beams to mount the outdoor units for ERLQ 004-008
Drainpan and U-beams for outdoor units ERLQ 004-008
Drainpan kit for indoor units EHBX 004-016
Heater mat for drainpan (EKDP008C)
Pair of flexi feet to mount the outdoor unit
Wall mounting bracket for outdoor units ERLQ 004-008 (90kg, 500mm long)
Wall mounting bracket for outdoor units ERLQ 011-016 (140kg, 540mm long)
Condensate drip tray for use with K.CWB90-2
Condensate drip tray for use with K.CWB140-2
Outdoor unit guard for ERLQ 004-008
Outdoor unit guard for ERLQ 011-016
£88.00
£80.00
£180.00
£180.00
£61.00
£46.00
£104.00
EKFT008CA
EKDP008C
EKHBDPC2
EKDPH008C
K.FF600ASN
K.CWB90-2
K.CWB140-2
K.DT1
K.DT2
K.CGM
K.CGL
EHBX16CB9W
HEATING
EHBX04CB3V
i)User interface (EKRUCBL2) must be
ordered with every EHBH/X
ii) *Back-up heater can be re-wired as
3kW/1ph, 6kW/1ph, 6kW/3ph or
9kW/3ph
iii) **9W models only
iv)Only one optional remote sensor
can be installed. Sensor connects to
indoor hydrobox
£83.00
£116.00
£112.00
£176.00
£47.00
£36.00
£45.00
£54.00
£59.00
£290.00
£354.00
Features:
> Available in heating only or heating/cooling versions
> A choice of back-up heaters 3, 6 or 9kW
> Heating / cooling hydroboxes must be ordered with drain pan kit
Price List 2016
121
NEW
EDLQ Standard Configurations
Low Temperature Monobloc Heat Pump (5-7kW)
Part Number
Description
Trade Price
UK.MONO5
5kW base configuration for heating and hot water containing:
£2,100.00
EDLQ05CV3
EKCB07CV3
EKRUCBL2
5kW outdoor unit (heating only)
Wiring centre
User interface
£1,800.00
£212.00
£88.00
UK.MONO7
7kW base configuration for heating and hot water containing:
£2,400.00
EDLQ07CV3
EKCB07CV3
EKRUCBL2
7kW outdoor unit (heating only)
Wiring centre
User interface
£2,100.00
£212.00
£88.00
UK.MONO5GROUND
5kW ground mounted configuration for heating and hot water containing:
£2,214.00
EDLQ05CV3
EKCB07CV3
EKRUCBL2
K.FF600ASN
K.HOSE750
5kW outdoor unit (heating only)
Wiring centre
User interface
Pair of flexi feet
Pair of flexible hoses 750mm
£1,800.00
£212.00
£88.00
£47.00
£67.00
7kW ground mounted configuration for heating and hot water containing:
£2,514.00
7kW outdoor unit (heating only)
Wiring centre
User interface
Pair of flexi feet
Pair of flexible hoses 750mm
£2,100.00
£212.00
£88.00
£47.00
£67.00
HEATING
UK.MONO7GROUND
EDLQ07CV3
EKCB07CV3
EKRUCBL2
K.FF600ASN
K.HOSE750
122
Residential, Commercial and Industrial
NEW
EDLQ
Low Temperature Monobloc Heat Pump (5-7kW)
Outdoor Unit
EDLQ05CV3
User Interface (must be ordered)
Description
Combined Trade Unit Price
Dimensions
Weight
Capacity
Input
COP
Seasonal space
heating efficiency
EKRUCBL2
5kW, 1-phase, 230V
7kW, 1-phase, 230V
£1,888.00
Height x Width x Depth
Heating (a/b)
Heating (a/b)
Space heating
(Average climate) 35°C
Space heating
(Average climate) 55°C
Operation Range
EDLQ07CV3
EKRUCBL2
Heating
Hot Water
Sound pressure/Power level
Refrigerant charge
R-410A
Power supply
Recommended Fuses
Pump
No. of speeds
Expansion vessel volume
Water connections
Diameter
Max piping length OU to cylinder
mm
kg
kW
kW
Class
Efficiency
SCOP
Class
Efficiency
SCOP
°C
°C
dBA
kg
£2,188.00
735 × 1085 × 350
76
4.40 / 4.20
0.88 / 1.95
5.00 / 2.15
A++
172
4.39
A++
125
3.20
80
7.00 / 6.25
1.55 / 3.09
4.52 / 2.02
A++
163
4.14
A++
126
3.22
-25 ~ +25
-25 ~ +35
48 / 61
1.30
49 / 62
1.45
1-phase / 230V / 50Hz
Amps
16
20
Inverter Controlled
7
1” (male)
10
litres
Inch
mm
Nominal capacity and nominal input tested according to EN 14511 at the following conditions
Heating a: Ambient air temperature 7C and leaving water temperature 35C (A7 W35)
Heating b: Ambient air temperature -7C and leaving water temperature 45C (A-7 W45)
Sound pressure level measured at 1m from the unit
WIRING CENTRE
£212.00
Depth
Width
Height
mm
mm
mm
BACK UP HEATER KIT (OPTIONAL)
Description
Trade Unit Price
Power supply
Recommended fuses
Water connections
HEATING
Wiring centre
Trade Unit Price
Nominal rating
Dimensions
i)User interface (EKRUCBL2) must be
ordered with every EDLQ05-07
EKCB07CV3
Description
To use with
Dimensions
Notes:
Depth
Width
Height
kW
mm
mm
mm
3 kW 1ph 230V
6 kW 1ph 230V
Diameter
Amps
Amps
inch
EDLQ05~07CV3
97
340
360
EKMBUHC3V3
EKMBUHC9W1
Back up heater kit (3kW)
Back up heater kit (3/6kW)
£436.00
£485.00
3
3-6
210
250
560
1-phase / 230V / 50Hz
1-phase / 230V / 50Hz
16
-
32
1” (male)
Accessories:
Accessory Ref
Description
Trade Price
EKRUCBL2
EKRUCBS
RTRNETA3AA
EKPCCAB3
EKSRC1
KRCS01-1
EK2CB07CV3
K.FF600ASN
K.CWBXL
K.DT2
K.HOSE750
K.HOSE750EL
User interface
Optional simplified room thermostat
Netatmo thermostat for smartphone
PC cable – to upload field settings from PC to unit or spare controller
Optional remote outdoor temperature sensor (see note)
Optional remote indoor temperature sensor (see note)
Optional Wiring centre - for remote alarm monitoring, run and fault indication and bivalent operation
Pair of flexi feet to mount the outdoor unit
Wall mounting brackets for outdoor units (250kg, 660mm long)
Condensate drip tray for use with K.CWBXL
Pair of flexible hoses (Length 750mm, 19mm tough PVC coat insulation, 1" FBSP, 28mm compression)
Pair of flexible hoses with elbow (Length 750mm, 19mm tough PVC coat insulation,
1" FBSP, 28mm compression)
Outdoor unit guard
£88.00
£80.00
£180.00
£180.00
£61.00
£46.00
£212.00
£47.00
£68.00
£59.00
£67.00
£97.00
Notes:
£275.00
i)Only one optional remote sensor can
be installed
K.CG750S
Features:
>The small Daikin Altherma Monobloc is ideal for smaller properties
>In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that no special refrigerant handling is necessary
>The optional back-up heater is installed indoors
Price List 2016
123
Heating Only EDHQ
Low Temperature Monobloc Heat Pump (14-16kW)
Outdoor Unit
Single Phase
Description
Trade Unit Price
Function
Dimensions
Height x Width x Depth
Weight
Nominal input
EDHQ014BB6W1
EDHQ016BB6W1
14kW, 1-phase, 230V
16kW, 1-phase, 230V
14kW, 3-phase, 400V
16kW, 3-phase, 400V
£2,840.00
£3,210.00
£3,000.00
£3,400.00
Heating Only
Heating Only
Heating Only
Heating Only
mm
Heating (a/b)
kW
Cooling
kW
Heating (a/b)
kW
Cooling
kW
COP
Heating (a/b)
Seasonal space
heating efficiency
Space heating
(Average climate) 35°C
Space heating
(Average climate) 55°C
EER
1418 x 1435 x 382
1418 x 1435 x 382
180
14 / 7.72
180
16 / 8.7
14 / 7.72
16 / 8.7
3.29 / 3.76
3.88 / 4.44
3.31 / 3.84
3.81 / 4.39
-
-
4.25 / 2.05
4.12 / 1.96
4.23 / 2.01
Class
A+
A+
A+
A+
Efficiency
130
123
130
127
SCOP
3.32
3.15
3.31
3.25
Class
A+
A+
A+
A+
Efficiency
105
101
110
111
SCOP
2.71
2.6
2.82
Cooling
Operation range
4.2 / 1.98
2.85
-
-15~35
Heating
°C
-15~35
Cooling
°C
-
-
Hot water
°C
-15~35
-15~35
Sound pressure /
power level
Heating
dBA
Cooling
dBA
Refrigerant charge (factory)
R-410A
Back up heater (factory fitted)
Recommended fuses
Pump
51 / 65
52 / 66
51 / 65
53 / 66
-
-
kg
2.95
2.95
kW
6
6
1-phase / 230V / 50Hz
3-phase / 400V / 50Hz
Power supply
HEATING
EDHQ016BB6V3
kg
Nominal capacity
3 Phase
EDHQ014BB6V3
Outdoor unit
A
32
20
6kW BUH
A
32
20
No. of speeds
Expansion vessel volume
2
2
10
10
1 ¼ (female)
1 ¼ (female)
10
10
litres
Water connections (diameter)
inches
Max piping length OU to cylinder
m
Nominal capacity and nominal input tested according to EN 14511 at the following conditions:
Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)
Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)
Sound pressure level measured at 1m from the unit
Accessories:
Notes:
Accessory Ref
Description
Trade Price
EKBPHTH16A
EKRP1HBA
Bottom plate heater for outdoor units sizes 014-016 (see note)
Optional PCB kit for remote alarm monitoring, run and fault indication,
solar interlock for heat pump and bivalent operation
Netatmo thermostat for smartphone
Optional wired room thermostatic controller
Optional wireless room thermostatic controller
Floor temperature sensor for use with wireless room thermostat EKRTR
£132.00
£104.00
RTRNETA3AA
EKRTWA
EKRTR
EKRTETS
£180.00
£99.00
£194.00
£14.00
Features:
>The Daikin Altherma Monobloc contains all components and the back-up heater in the outdoor unit
>In this system, water pipes, rather than refrigerant lines, run from the outdoor unit to indoors which means that
no special refrigerant handling is necessary for installation
124
Residential, Commercial and Industrial
i)It is strongly recommended to install the
bottom plate heater in units that will be
installed in a region that will experience
prolonged periods below 0°C with very
high humidity
ii)Every unit is supplied with a controller
Heating and Cooling EBHQ
Low Temperature Monobloc Heat Pump (14-16kW)
Outdoor Unit
Single Phase
3 Phase
EBHQ014BB6V3
EBHQ016BB6V3
EBHQ014BB6W1
EBHQ016BB6W1
14kW, 1-phase, 230V
16kW, 1-phase, 230V
14kW, 3-phase, 400V
16kW, 3-phase, 400V
Trade Unit Price
£2,950.00
£3,330.00
£3,110.00
£3,515.00
Function
Reversible
Reversible
Reversible
Description
mm
Heating (a/b)
kW
14 / 7.72
16 / 8.7
14 / 7.72
Cooling
kW
12.5
13.1
12.5
13.1
Heating (a/b)
kW
3.29 / 3.76
3.88 / 4.44
3.3 / 3.84
3.81 / 4.39
Cooling
kW
Weight
Nominal capacity
Nominal input
1418 x 1435 x 382
Reversible
Height x Width x Depth
kg
COP
Heating (a/b)
Seasonal space
heating efficiency
Space heating
(Average climate) 35°C
Space heating
(Average climate) 55°C
1418 x 1435 x 382
180
180
16 / 8.7
5.39
5.93
5.06
5.75
4.25 / 2.05
4.12 / 1.96
4.23 / 2.01
4.2 / 1.98
Class
A+
A+
A+
A+
Efficiency
130
123
130
127
SCOP
3.32
3.15
3.31
3.25
Class
A+
A+
A+
A+
Efficiency
105
101
110
111
SCOP
2.71
2.6
2.82
2.85
2.32
2.21
2.47
EER
Cooling
Operation range
Heating
°C
Cooling
°C
10~46
10~46
Hot water
°C
-15~35
-15~35
Sound pressure /
power level
Heating
dBA
51 / 65
52 / 66
51 / 65
Cooling
dBA
52 / 66
54 / 69
52 / 66
Refrigerant charge (factory)
R-410A
kg
Back up heater (factory fitted)
Recommended fuses
Pump
-15~35
53 / 66
54 / 69
2.95
kW
Power supply
2.28
-15~35
2.95
6
6
1-phase / 230V / 50Hz
3-phase / 400V / 50Hz
Outdoor unit
A
32
20
6kW BUH
A
32
20
No. of speeds
Expansion vessel volume
2
2
10
10
1 ¼ (female)
1 ¼ (female)
10
10
litres
Water connections (diameter)
inches
Max piping length OU to cylinder
m
HEATING
Dimensions
Nominal capacity and nominal input tested according to EN 14511 at the following conditions:
Heating a: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35) Heating b: Ambient air temperature -7°C and leaving water temperature 45°C (A-7 W45)
Cooling: Ambient air temperature 35°C and leaving water temperature 7°C (A35 W7)
Sound pressure level measured at 1m from the unit
EKHWSU
Hot Water Cylinder for Low Temperature Split and Monobloc
Domestic hot water cylinder
Description
Trade Unit Price
Suitable for
Energy efficiency class
Standing heat loss (ErP)
Storage volume
Standing heat loss
Max water temperature
Booster heater capacity
Power supply
Recommended fuses
Height
Diameter
Empty weight
Material inside cylinder
Piping connections (diameter)
W
L
kWh/24h
°C
kW
A
mm
mm
kg
Water inlet H/E
Water outlet H/E
Cold water in
Hot water out
inch
inch
inch
inch
UK.EKHWSU150B3V3
UK.EKHWSU200B3V3
UK.EKHWSU300B3V3
150L unvented cylinder
(Including EKUHWBB)
200L unvented cylinder
(Including EKUHWBB)
300L unvented cylinder
(Including EKUHWBB)
£1,064.00
£1,081.00
Unvented systems (EKUHWBB kit included)
C
74
200
177
85
3
1-phase / 230V / 50Hz
16
1265
580
46
Stainless steel
3/4 (female)
3/4 (female)
3/4 (female)
3/4 (female)
£1,188.00
C
65
150
115
1015
38
C
91
285
219
1715
60
Features:
>This stainless steel unvented cylinder is the ideal partner for Daikin Altherma Low Temperature Split and Monobloc heat pumps
>Fitted with 3kW immersion heater as standard
>Supplied with 3-way valve and G3 safety kit (EKUHWBB)
>For vented hot water cylinders, please contact your local sales office
Price List 2016
125
ERSQ
High Temperature Split Heat Pump (outdoor)
Outdoor Unit
Single Phase
Description
Trade Unit Price
Dimensions
3 Phase
ERSQ011AV1
ERSQ014AV1
ERSQ016AV1
ERSQ011AY1
ERSQ014AY1
ERSQ016AY1
11kW,
1-phase, 230V
14kW,
1-phase, 230V
16kW,
1-phase, 230V
11kW,
3-phase, 400V
14kW,
3-phase, 400V
16kW,
3-phase, 400V
£2,472.00
£2,789.00
1345 x 900 x 320
£3,013.00
£2,699.00
£2,831.00
1345 x 900 x 320
£3,345.00
Height x Width x Depth
mm
Nominal capacity
Heating (a/b)
kW
11 / 11
14 / 14
16 / 16
11 / 11
14 / 14
16 / 16
Nominal input
Heating (a/b)
kW
3.03 / 3.57
4.07 / 4.66
4.83 / 5.57
3.03 / 3.57
4.07 / 4.66
4.83 / 5.57
COP
Heating (a/b)
3.63 / 3.08
3.44 / 3.00
3.31 / 2.88
3.63 / 3.08
3.44 / 3.00
3.31 / 2.88
Seasonal space
heating efficiency*
Space heating
(Average climate) 35°C
B
B
B
B
B
B
Efficiency
105
110
112
105
110
112
2.88
Weight
kg
Class
120
120
SCOP
2.7
2.68
2.88
2.7
2.68
Space heating
(Average climate) 55°C
Class
A+
A+
A+
A+
A+
A+
Efficiency
103
104
102
103
104
102
SCOP
2.65
2.66
2.61
2.65
2.66
2.61
Operation range
Heating
°C
Hot water
°C
Sound pressure / power level
Refrigerant charge
Heating
R-410A
dBA
kg
Piping connections
-20 ~ + 24
-20 ~ + 24
-20 ~ + 35
52 / 68
53 / 69
4.5
-20 ~ + 35
55 / 71
52 / 68
53 / 69
4.5
Liquid
inches
3/8
3/8
Gas
inches
5/8
5/8
Max piping length OU to IU
m
Power supply
Recommended fuses
50
50
1-phase / 230V / 50Hz
3-phase / 400V / 50Hz
25
16
A
* When combined with matching indoor unit
Nominal capacity and nominal input tested at the following conditions:
a. A7 W45 according to EN14511
55 / 71
b. A7 W65 according to Eurovent rating standard 6/C/003-2006
Features:
HEATING
>The outdoor unit extracts heat from the ambient air and transfers it to the
indoor unit via refrigerant piping
> Heating only versions
> Order with matching indoor unit
EKHBRD
High Temperature Split Hydrobox (floor standing)
Indoor Unit (floor standing)
Single Phase
3 Phase
EKHBRD011ADV1 EKHBRD014ADV1 EKHBRD016ADV1 EKHBRD011ADY1 EKHBRD014ADY1 EKHBRD016ADY1
Description
11kW,
1-phase, 230V
Trade Unit Price
To use with
Dimensions
Height x Width x Depth
Weight
Leaving water temperature range
Refrigerant charge (factory)
R134a
Power supply
Recommended fuses
Pump
No. of speeds
Expansion vessel volume
Water connections (diameter)
14kW,
1-phase, 230V
16kW,
1-phase, 230V
£2,985.00
ERSQ011AV1
mm
kg
°C
kg
A
litres
inch
£3,038.00
£3,130.00
ERSQ014AV1
ERSQ016AV1
705 x 600 x 695
144.25
25~80 without electrical heater
3.2
1-phase / 230V / 50Hz
25
Inverter controlled
12
1 (female)
11kW,
3-phase, 400V
14kW,
3-phase, 400V
16kW,
3-phase, 400V
£3,045.00
ERSQ011AY1
£3,099.00
£3,192.00
ERSQ014AY1
ERSQ016AY1
705 x 600 x 695
147.25
25~80 without electrical heater
3.2
3-phase / 400V / 50Hz
16
Inverter controlled
12
1 (female)
Features:
> The indoor unit receives the heat from the outdoor unit and further increases
the temperature up to 80°C, which is ideal for use with existing radiators
> It is designed to only be used with the integrated hot water cylinder EKHTSU
> For RHI, check maximum design flow temperature carefully
Accessories:
Accessory Ref
RTRNETA3AA
EKBPHTH16A
EKBUHA6V3
EKBUHA6W1
EKRP1AHT
EKRUAHTB
EKRP1HBA
EKRTWA
EKRTR
EKRTETS
RTD-W
K.CWB140-2
K.DT2
K.CGL
K.FF600ASN
126
Description
Netatmo thermostat for smartphone
Bottom plate heater for outdoor unit sizes 011-016
In line back up electric heater 6kW, 1-phase, 230V (also requires EKRP1AHT) – for space heating only
In line back up electric heater 6kW, 3-phase, 400V (also requires EKRP1AHT) – for space heating only
Optional PCB for demand control (required for EKRTW, EKRTR, EKRTETS, EKBUH*)
Remote user interface
Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock for heat pump
Optional wired room thermostatic controller (also requires EKRP1AHT)
Optional wireless room thermostatic controller (also requires EKRP1AHT)
Floor temperature sensor for use with EKRTR (also requires EKRP1AHT)
MODBUS interface for HT hydrobox
Wall mounting bracket for outdoor unit ERSQ 011-016
Condensate drip tray for use with K.CWB140-2
Outdoor unit guard for ERSQ 011-016
Pair of flexi feet to mount the outdoor unit
Residential, Commercial and Industrial
Trade Price
£180.00
£132.00
£461.00
£461.00
£104.00
£157.00
£104.00
£99.00
£194.00
£14.00
£205.00
£46.00
£59.00
£354.00
£68.00
EKHTSU
Hot Water Cylinder for High Temperature Split
Domestic hot water cylinder
Description
Trade Unit Price
Suitable for
Energy efficiency class
Standing heat loss (ErP)
Storage volume
Max water temperature
Standing heat loss
Dimensions (cylinder only)
Dimensions (cylinder
integrated on hydrobox)
Empty weight
Material inside cylinder
Piping connections (diameter)
UK.EKHTSU200AC
UK.EKHTSU260AC
200L unvented cylinder
260L unvented cylinder
£1,113.00
£1,261.00
Unvented systems (including EKUHWHTB)
Height x Width x Depth
Height x Width x Depth
W
L
°C
kWh/24h
mm
mm
kg
Water inlet H/E
Water outlet H/E
Cold water in
Hot water out
mm
mm
inch
inch
B
50
200
B
63
260
75
12
1335 x 600 x 695
2010 x 600 x 695
15
1610 x 600 x 695
2285 x 600 x 695
70
78
Stainless steel
25 (female quick coupling, supplied, integrated solution)
25 (female quick coupling, supplied, integrated solution)
3/4 (female)
3/4 (female)
Accessories:
Accessory Ref
Description
Trade Price
EKFMAHTB
Kit for standalone installation with floor standing hydrobox
£277.00
Features:
HEATING
>This integrated cylinder is designed for use with Daikin Altherma HT only
>The cylinder features fast heat-up and recovery times, and low heat losses
>The indoor unit and hot water cylinder are designed to be stacked to save space, or can alternatively be
installed next to each other if limited height is available for installation (please order EKFMAHTB)
>Supplied with 3-way valve and G3 safety kit (EKUHWHTB)
Price List 2016
127
Air-to-Water Heat Pump Combination Table
Daikin have a full range of air-to-water heat pumps to suit many installation requirements and applications.
Use the table below to help select the right combination of equipment.
LT Split 4-16kW
Outdoor
Indoor
DHW cylinder
or
Thermal store
or
ERLQ004-008
(page 120)
EHBH/X04-16
ERLQ011-016
(page 121)
LT Monobloc 5-7kW
LT Monobloc 14-16kW
UK.EKHWSU150-300B
or
Wiring centre EKCB
(page 123)
EDLQ05-07
(page 123)
Back-up heater (optional)
EKMBUH
UK.EKHWSU150-300B
(page 123)
(page 125)
EKHWP300-500(P)B
or
EDHQ/EBHQ014-016
UK.EKHWSU150-300B
(page 124 - 125)
128
EKHWP300-500(P)B
(page 125)
EKHWP300-500(P)B
(page 125)
HT Split 11-16kW
HEATING
(page 120)
or
ERSQ011-016
EKHBRD011-016
UK.EKHTSU200-260AC
(page 126)
(page 126)
(page 127)
Residential, Commercial and Industrial
EKHWP300-500(P)B
Hybrid Heat Pump
The Daikin Altherma Hybrid Heat Pump is unique
technology. It combines a high efficiency gas combi
boiler with a renewable energy air-to-water heat
pump, all in one efficient, compact heating system.
Daikin Altherma Hybrid heat pump
The smart hybrid logic automatically selects the most energy
efficient and cost-effective operation based on the user’s
energy tariff, at any given temperature to make it the most
efficient solution on the market.
> Simple easy to use backlit control using energy tariffs for
automatic control
> S uitable for heating systems requiring flow temperatures
up to 80°C
> Heat pump capacity: 5 and 8kW
> E ligible for RHI when fitted with required heat and
electric meters
> Single compact indoor unit to minimise space
> No DHW tank needed – hot water delivered by combi boiler
> All key components built in: A-label pump, expansion vessel,
pressure relief
> Boiler output CH 27kW (80/60) and DHW 33kW
(13 l/min at ΔT 35K)
> Boiler SEDBUK (2009) rated 89.1% (natural gas) and 90.1% (LPG)
> Dedicated training courses available
HEATING
> S uitable for LPG applications for even higher running
cost savings
Price List 2016
129
EVLQ / EHYHBH / EHYKOMB
Daikin Altherma Hybrid Heat Pump System
Outdoor Units
Dimensions
Weight
Nominal capacity
Nominal input
COP
Seasonal space
heating efficiency*
EVLQ05CV3
Height x Width x Depth
Heating
Heating
Heating
Space heating
(Average climate) 55°C
Domestic
hot water heating*
Average climate
Operation range (ambient)
Sound pressure / power level
Refrigerant charge
Piping connections
Heating
Heating
R-410A
Liquid
Gas
Max piping length OU to IU
Power supply
Recommended fuses
mm
kg
kW
kW
Class
Efficiency
SCOP
Class
hwh
Declared load profile
°C
dBA
kg
inches
inches
m
EVLQ08CV3
735 x 832 x 307
54
4.4
0.87
5.04
A++
128
3.28
A
95
XL
56
7.4
1.66
4.45
A++
127
3.24
A
95
XL
-25~25
48 / 61
1.45
49 / 62
1.6
1/4
5/8
20
1-phase / 230V / 50Hz
20
A
* When combined with matching indoor unit
Indoor Unit and boiler wall hung (1 combined unit)
HEATING
Indoor Unit (heat pump)
Function
To use with
Dimensions
Weight
Leaving water
temperature range
Pump
Expansion vessel volume
Indoor Unit (boiler)
Height x Width x Depth
Heating
mm
kg
°C
No. of speeds
litres
Function
To use with
Dimensions
Max dimensions
(boiler and heat pump)
Weight
Capacity (heating)
Capacity (hot water)
Leaving water
temperature range
DHW flow rate ΔT 35K
Heating connections
DHW connections
Gas connection
IP rating
Device type
Supply pressure
Nox class
Flue gas connection
Maximum flue length, 60/100
Maximum flue length, 80/125
SEDBUK rating (2009)
Height x Width x Depth
Height x Width x Depth
mm
mm
Minimum
Maximum
Minimum
Maximum
Heating
Hot water
Hot water
Diameter
Diameter
Diameter
kg
kW
kW
kW
kW
°C
°C
l/min
mm
mm
mm
Natural gas (G20)
LPG (G31)
mbar
mbar
m
m
%
Nominal capacity and nominal input tested according to EN 14511 at the following conditions:
Heating: Ambient air temperature 7°C and leaving water temperature 35°C (A7 W35)
Sound pressure level measured at 1m from the unit
130
Residential, Commercial and Industrial
EHYHBH05AV32
EHYHBH08AV32
Heating Only
EVLQ05CV3
Heating Only
EVLQ08CV3
1075 x 450 x 164
30
31.2
25~55
Inverter controlled
10
EHYKOMB33AA2
Heating only
EHYHBH05AV32
EHYHBH08AV32
710 x 450 x 240
1075 x 450 x 405
36
7.6
27
7.6
32.7
15 ~ 80
40 ~ 65
13.1
22
15
15
IP44
C13, C33, C53
20
30-37
5
60/100
10
29
89.1 (NG) / 90.1 (LPG)
EVLQ / EHYHBH / EHYKOMB
Daikin Altherma Hybrid Heat Pump System
Part Number
Description
Trade Price
UK.HYBRID05B33
Hybrid 5kW pack
£3,400.00
EVLQ05CV3
EHYHBH05AV32
EHYKOMB33AA2
EKRUCBL2
EKHY093467
EKVK3A
Outdoor unit: 5kW, 1-phase, 230V
Hydrobox: 5kW, 1-phase, 230V
Hybrid combi boiler: 33/27kW
User interface
Pipe cover plate
Hybrid valve pack
UK.HYBRID08B33
Hybrid 8kW pack
This pack contains:
£3,850.00
This pack contains:
EVLQ08CV3
EHYHBH08AV32
EHYKOMB33AA2
EKRUCBL2
EKHY093467
EKVK3A
Outdoor unit: 8kW, 1-phase, 230V
Hydrobox: 8kW, 1-phase, 230V
Hybrid combi boiler: 33/27kW
User interface
Pipe cover plate
Hybrid valve pack
Accessories:
Accessory Ref
Description
Trade Price
K.HEATMET
Heat meter for domestic RHI (for Altherma hybrid only)
Class 3 heat meter delivered with body, digital interface and 2 temperature sensors
Electric meter for RHI (single phase)
IEC Class 1 electric meter to measure the electricity consumption of the Daikin Altherma heat pump
LPG conversion kit
Flue adapter 80/125
PC cable – to upload field settings from PC to unit or spare controller
Optional PCB kit for remote alarm monitoring, run and fault indication and solar interlock
Optional simplified room thermostat
Netatmo thermostat for smartphone
Optional remote temperature sensor for outdoor temperature (see note)
Optional remote temperature sensor for indoor temperature (see note)
U-beams to mount the outdoor unit EVLQ05CV3
Drainpan and U-beams for outdoor unit EVLQ05CV3
Heater mat for drainpan (EKDP008C)
Pair of flexi feet to mount the outdoor unit
Wall mounting bracket for outdoor unit
Condensate drip tray for K.CWB90-2
Outdoor unit guard
£170.00
EKHY075787
EKHY090717
EKPCCAB3
EKRP1HBA
EKRUCBS
RTRNETA3AA
EKRSC1*
KRCS01-1*
EKFT008CA
EKDP008C
EKDPH008C
K.FF600ASN
K.CWB90-2
K.DT1
K.CGM
£109.00
i)* O
nly one optional remote sensor
can be installed
£20.00
£20.00
£180.00
£104.00
£80.00
£180.00
£61.00
£46.00
£83.00
£116.00
£176.00
£47.00
£36.00
£54.00
£296.00
HEATING
K.ELECMETV
Notes:
Features:
>Revolutionary hybrid heat pump system with higher efficiency and higher running cost savings than condensing boiler alone
>Boiler can be converted to run on LPG
>Delivered as a set including outdoor unit, indoor unit, boiler, controller and pipe cover plate
>Flues ordered separately
Daikin Altherma Hybrid Heat Pump System
Hybrid Tank Connection Kits
Part Number
Description
Trade Price
EKEPHT3H
Daikin thermal store (EKHWP-B)
£174.00
This pack contains:
3 way valve (Honeywell)
Tank sensor (HT + adapter)
2 x isolation valves
T-piece
EKHY3PART
Third party tank – dry pocket sensor
£145.00
This pack contains:
3 way valve (ESBE)
Tank sensor (LT)
EKHY3PART2
Third party tank – thermostat only
£175.00
This pack contains:
3 way valve (ESBE)
Wire harness
Price List 2016
131
Daikin Altherma Hybrid Heat Pump System
HEATING
Flue Accessories (60/100)
132
Description
Quantity per pack
Part number
Trade Price
Horizontal flue kit 60/100
1
EKFGP1292
£43.00
Horizontal flue kit
with low profile elbow 60/100
1
EKFGP1293
£52.00
Extension 60/100 x 500mm
1
EKFGP4651
£25.00
Extension 60/100 x 1000mm
1
EKFGP4652
£30.00
Elbow 60/100, 30 degrees
1
EKFGP4664
£33.00
Elbow 60/100, 45 degrees
1
EKFGP4661
£22.00
Elbow 60/100, 87 degrees
1
EKFGP4660
£22.00
Tee with inspection panel 60/100
1
EKFGP4667
£82.00
Wall bracket DN.100
1
EKFGP4631
£6.00
Plume Management Kit (PMK)
1
EKFGP1294
£36.00
Flue deflector
1
EKFGP1295
£14.00
Residential, Commercial and Industrial
Daikin Altherma Hybrid Heat Pump System
Flue Accessories (60/100)
(Continued)
Quantity per pack
Part number
Trade Price
PMK elbow, 87 degrees
1
EKFGP1284
£12.00
PMK elbow, 45 degrees
2
EKFGP1285
£20.00
PMK extension,
length 1000mm incl. bracket
1
EKFGP1286
£18.00
Vertical roof terminal 60/100
1
EKFGP6837
£60.00
Weather slate (plastic) 60/100
(25-45 degrees)
1
EKFGP7910
£27.00
18-22 degrees
1
EKFGS0518
£90.00
23-27 degrees
1
EKFGS0519
£90.00
43-47 degrees
1
EKFGS0523
£90.00
48-52 degrees
1
EKFGS0524
£90.00
53-57 degrees
1
EKFGS0525
£90.00
Weather slate flat aluminium 60/100
1
EKFGP6940
£20.00
Weather slate flat aluminium 60/100
(0 – 15 degrees)
1
EKFGP1296
£50.00
HEATING
Description
Weather slate 60/100
Price List 2016
133
Netatmo
HEATING
Netatmo by Starck
Take control of your home’s
temperature with the
Thermostat for smartphones,
tablets, and laptops, designed
by Starck.
Accessory
Trade Unit Price
Temperature (setpoint)
Wireless Specifications
£180.00
Height
Width
Depth
Class
Contribution
Range
Accuracy
Setpoint range
Increment measure
Wi-Fi
Security
Power
Netatmo combination tables:
Product
Series
Daikin Altherma air source heat pump
EHBH-CB
EDLQ-C*
EDHQ-BB
EKHBRD-AD**
EHYHBH-A
*Wiring centre EKCB07CV3
**Option PCB type EKRP1AHTA is required
134
> O
nce installed, Netatmo gives the user precise remote control of
heat output, a weekly schedule reflecting the family’s habits and
monthly energy savings reports. This can help you reduce your
energy consumption by up to 25% by only heating when you
need it.
Netatmo Smart Thermostat
Dimensions
Temperature (measures)
> W
ith all the functionality of a programmable room thermostat,
Netatmo may be fixed to a wall or used wirelessly. It is installed
together with a user interface on smartphone, tablet or computer.
RTRNETA3AA
Description
Product fiche
Netatmo gives homeowners the option to control their
heating temperature via an easy to use smartphone app.
Residential, Commercial and Industrial
%
°C
°C
°C
°C
83
83
22
IV
2.0
0 ~ 50
±0.5
5 ~ 30
0.5
802.11b/g/n (2.4GHz)
Open/WEP/WPA/WPA2-Personal (TKIP et AES)
3 AAA batteries
Daikin solar systems maximise the use of renewable free energy from
the sun through high efficiency flat plate collectors. The Daikin solar
thermal system is available in drainback and pressurised options and
is designed to work in conjunction with Daikin Altherma air-to-water
heat pumps for maximum efficiency. Solar panels are Solar Keymark
approved and eligible for the Domestic RHI.
Drainback solar system
Pressurised solar system
> T he drainback solar system is a low maintenance system which
does not need antifreeze agents
> T he pressurised solar system transfers heat to the unvented
cylinder via a specially designed heat exchanger kit. This allows
the entire cylinder to be heated by solar energy
> It consists of an unpressurised thermal store which can be
combined with Daikin Altherma heat pumps or another
auxiliary heat source
> W
ater in the store is pumped to the solar panels, heated and
returns to stratify in the Daikin thermal store
> W
hen solar energy is not available, the solar collectors empty
and water drains back to the store
> D
uring solar heating, the heat pump is disabled to ensure
maximum efficiency
Standalone solar system
> T he standalone solar system combines a pressurised solar
system and a twin-coil unvented cylinder and is designed to
be combined with an auxiliary gas boiler
> Ideal for on-gas retrofit applications
Solar pressurised
Solar drainback
Price List 2016
135
HEATING
Solar Thermal
Solar Panel EKSV / EKSH
Type
Dimensions
Height x Width x Depth
Weight
Max operating pressure
Max standstill temp
Information for SAP assessors and for MCS installers
Gross / net aperture area
Zero loss efficiency
Heat loss coefficient (a1)
Heat loss coefficient (a2)
Solar panel
mm
kg
Bar
°C
m2
W/m2.K
W/m2.K2
Solar pump station
Solar controller
DHW Thermal Store
EKSV21P
Vertical
2000 x 1006 x 85
35
6
200
EKSV26P
Vertical
2000 x 1300 x 85
42
6
200
EKSH26P
Horizontal
1300 x 2000 x 85
42
6
200
2.0 / 1.8
0.784
4.25
0.0072
2.6 / 2.36
0.784
4.25
0.0072
2.6 / 2.36
0.784
4.25
0.0072
Solar Pump Station EKSRD / EKSRP
System
Dimensions
Height x Width x Depth
Power supply
Solar pump
Max pump power consumption
Max operating pressure
Max pump capacity
Temperature range
Connections
mm
W
Bar
m3/h
°C
-
EKSRDS2A
pressurised
410 x 240 x 130
230 / 50Hz
Grundfos UPM3 Solar 25-75
22.5
6
2
0-120 (160 short term)
1¼” female for Ø 22
clamping ring bolt (x4)
EKSRPS4A
drainback
230 x 815 x 142
230 / 50Hz
Grundfos UPS 15-145
65
-
162084
60 x 145 x 95
230 / 50Hz
5
Plain text
Part of EKSRPS4A
230 / 50Hz
2
Plain text
HEATING
Solar Controller
Dimensions
Power supply
Max electric consumption
Display
Height x Width x Depth
mm
W
DHW Thermal Store EKHWP
Storage capacity
Weight (empty)
Weight (filled)
Dimensions
Height x Width x Depth
Max storage temp
Heat loss at 60°C
Energy efficiency class
Standing heat loss
Storage volume
Coil material
Potable water capacity
Max operating pressure (potable water)
DHW coil area
Solar thermal system
Information for SAP assessors and for MCS installers
Total volume (V)
Dedicated solar volume (Vs)
Surface area solar heat exchange coil
Heating coil capacity
Heating coil area
Pipe connections
Cold and hot water
Heating flow / return
Solar
Thermal output data
Volume of hot water at given draw-off rate;
without reheating
(inlet = 10 °C / outlet = 40 °C / store = 50 °C)
Reheat time (Wh) at given draw-off volume
(inlet = 10 °C / outlet = 40 °C / store = 50 °C)
litres
kgs
kgs
mm
°C
kWh/24h
W
L
litres
Bar
m2
136
EKHWP500B
EKHWP300PB
500
300
93
64
593
364
1640 x 790 x 790
595 x 615 x 1646
85
85
1.4
1.3
B
B
72
64
477
294
Stainless Steel 1.4404
29.0
27.9
6
6
6.0
2.7
27.9
6
5.8
Drainback
litres
litres
m2
litres
m2
EKHWP500PB
500
98
598
790 x 790 x 1658
85
1.4
B
72
477
29.0
6
3.8
Pressurised
300
300
N/A
13.2
2.7
Inches
Inches
Inches
500
500
N/A
18.5
3.8
1” outer thread
1” female / 1” male
1” internal thread
300
300
0.8
13.2
2.7
500
500
1.7
18.5
3.8
1” male
1” female / 1” male
3/4” female and 1” male
litres
8 l/min = 184
12 l/min = 153
8 l/min = 364 (1)
12 l/min = 318 (1)
8 l/m = 184
12 l/m = 153
8 l/m = 324 (1)
12 l/m = 282 (1)
mins
With 8kW heat pump
90 litres = 30
140 litres = 45
EKHWP300B
ERLQ004-8
EKDVCPLT3HX
EKBH3S
ERSQ011-16
EKEPHT3H
16 51 35
With 16kW heat pump
90 litres = 17
140 litres = 25
EKHWP500B
ERLQ011-16
EKDVCPLT5H
EKBH3S
ERSQ011-16
EKEPHT5H
16 51 35
With 8kW heat pump
90 litres = 30
140 litres = 45
EKHWP300PB
ERLQ004-8
EKDVCPLT3HX
EKBH3S
ERSQ011-16
EKEPHT3H
16 51 35
With 16kW heat pump
90 litres = 17
140 litres = 25
EKHWP500PB
ERLQ011-16
EKDVCPLT5H
EKBH3S
ERSQ011-16
EKEPHT5H
16 51 35
DHW Thermal store combination
Daikin Altherma LT
Connection kit (2)
Immersion heater (required)
Daikin Altherma HT
Connection kit
Immersion heater (optional)
1. with immersion heater
EKHWP300B
300
59
359
1640 x 615 x 595
85
1.4
B
64
294
2. connection kits include 3 way valve, sensors and isolation valves
Residential, Commercial and Industrial
Daikin Solar Thermal System
Solar Panels, Fixings and Installation Kits (common components)
Description
Part number
Trade Price
Solar panel (vertical) – standard
(2000 x 1300 x 85mm), aperture area 2.35m2, weight 42kg, water content 1.7 L. Max. 6 bar
EKSV26P
£404.00
EKSV21P
£338.00
EKSH26P
£415.00
Kit to couple 2 solar panels
Mounting profile connector, expansion joints and double clamping blocks
162016-RTX
£35.00
Mounting rail for vertical panels
Consisting of mounting profile rails and solar panel securing ties
162066
For EKSV21P
(Was 162013)
£24.00
162067
For EKSV26P
(Was EKSFIXMP130)
£30.00
162068
For EKSH26P
(Was EKSFIXMP200)
£42.00
162036-RTX
£69.00
164723
£40.00
164703-RTX
£50.00
Note: Max 5 panels
Solar panel (vertical) – small
(2000 x 1006 x 85mm), aperture area 1.79m2, weight 35kg, water content 1.3 L. Max. 6 bar
Note: Max 5 panels
Solar panel (horizontal) – standard
(1300 x 2000 x 85mm), aperture area 2.35m2, weight 42kg, water content 2.1 L. Max. 6 bar
Note: Different for standard and small panels
4x Support hooks for high profile tiles
4 double height-adjustable roof ties including fixing material for one solar panel
HEATING
Note: For pressurised systems only
Note: Was EKSFIXADP
4x Support hooks for flat tiles (slate)
4 roof ties for flat roofing, e.g. slate, for one solar panel
Note: Was EKSFIXADS
4x Support hooks for curved roofings
Including fixing material for one solar panel
Note: Was EKSFIXWD
Price List 2016
137
Daikin Solar Thermal System
Solar Panels, Fixings and Installation Kits (common components)
Description
Part number
Trade Price
4x Support hooks for sheet metal roofs
Including fixing material for one solar panel
164704-RTX
£47.00
162019
For EKSV26P
£256.00
162017
For EKSV21P
£426.00
162020
For EKSV26P
£199.00
162018
For EKSV21P
£190.00
162058
£382.00
162059
£152.00
162060
£181.00
162061
£125.00
164110-RTX
£11.00
EKRP1HBA
£104.00
Note: Was EKSFIXBD
In-roof installation kit for 2x vertical panels
For two solar panels, covering sheets complete with mounting material.
Minimum roof angle 15°
Note: Different for standard and small panels
In-roof extension kit for 1 additional vertical panel
For one further solar panel, covering sheets complete with mounting material.
Minimum roof angle 15°
Note: Different for standard and small panels
Flat roof kit for 2x vertical panels
Preassembled system for quick and easy assembly, with incremental adjustment
of solar panel inclination between 30-60 degrees
HEATING
Note: For EKSV26P only
Flat roof extension kit for 1 additional vertical panel
Preassembled system for quick and easy assembly, with incremental adjustment
of solar panel inclination between 30-60 degrees
Note: For EKSV26P only
Flat roof kit for 1 horizontal panel
Preassembled system for quick and easy assembly, with incremental adjustment
of solar panel inclination between 30-60 degrees
Note: For EKSH26P only
Flat roof extension kit for 1 additional horizontal panel
Preassembled system for quick and easy assembly, with incremental adjustment
of solar panel inclination between 30-60 degrees
Note: For EKSH26P only
Connection cable to disable heat pump
The connection cable is required to connect the solar priority PCB kit to heat pump
Note: N
eed to order EKRP1HBA with this part
Was EKS164110
Solar priority PCB kit
This enables an interlock between the Daikin solar controller and Altherma heat pumps
Note: Need to order 164110-RTX with this part
138
Residential, Commercial and Industrial
Daikin Solar Thermal System
Solar Pressurised Accessories
Description
Part number
Trade Price
162084
Solar controller
Solar differential temperature regulation for the Daikin solar pressurised system.
Regulator with graphic display for representation of hydraulic schematics and yield balances.
Including return flow and storage tank temperature sensor and housing for wall mounting
£191.00
Pump station
Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings
and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air separator,
ball valves with integrated backflow preventor, Grundfos UPM3 Solar 25-75 pump,
safety group with pressure gauge, including insulation and mounting accessories
EKSRDS2A
£284.00
Flow sensor for energy metering
Flow sensor for energy monitoring to enable automatic pump speed control to
maximise efficiency by measuring the flow volume and flow temperature
164116
£75.00
Hydraulic connection kit (pressurised)
Connection kit for pressurised only, includes connection to solar panel, 2m UV resistant
heat insulation for the external area, solar panel temperature sensor and end caps
EKSRCP
£112.00
Connection pipe for solar panel rows
Connection kit for connecting two rows of collectors one above the other.
Consisting of solar panel mounting material, equipotential bonding clamps, end caps,
connecting brackets and 1m thermally insulated piping
162045
£75.00
162052-RTX
£70.00
Thermostatic Mixing Valve
Thermal safety device for DHW outlet with a setting range from 35-60°C
156015 + 156016
£65.00 +
£27.00
15m solar pressurised pipe
Pre-insulated stainless steel flexible flow to panel (16mm) and return from panel (20mm)
pipe with sensor cable, order with fittings as shown
162073 + 162075
Up to 3 panels (DN16)
£240.00 +
£34.00
162074 + 162076
4-5 panels (DN20)
£350.00 +
£50.00
162071
Up to 25m (DN16)
£24.00
162072
Up to 25m (DN20)
£20.00
162050
25 litre
£56.00
162051-RTX
35 litre
£144.00
HEATING
Note: Was EKSFLP12A
Note: Was EKSCONLCP
Antifreeze fluid (glycol, 20L)
20L of pre-mixed solar fluid in a canister, SOL 5F.
Functional range up to -28°C
Note: Was EKSGFL
Note: Order connection pack separately
162073 + 162075 was 162021-RTX
162074 + 162076 was 162026-RTX
Solar pipe connectors
Connectors to fit 2 pipes together for extension of solar pipe
Note: 1
62071 was 162027-RTX
162072 was 162028-RTX
Solar expansion vessel
Bracket and flexi hose included for installation
Price List 2016
139
Daikin Solar Thermal System
Solar Drainback Accessories
Description
Part number
Trade Price
Solar controller and pump station
Unit ready to plug in (230V), with digital differential temperature control system,
return flow and storage tank temperature sensors and operating pump
EKSRPS4A
£416.00
Solar connection pipe
Ready to plug in connection pipe between the solar panel and the pump station,
consisting of thermally insulated flow pipe to panel (15mm) and return pipe from
panel (18mm) with integrated sensor cable.
Available in 15 and 20m lengths
164732
15m length
£94.00
164733
20m length
£112.00
164261-RTX
2.5m
£59.00
164262-RTX
5m
£67.00
164263
10m
£88.00
164264
£74.00
Copper pipe connection kit
164232
Connection kit when connecting onto copper pipe (if Daikin drainback pipe is not used).
Consisting of 2m flow and return pipes, push-fit coupling onto 15mm and 18mm copper pipe
£54.00
Solar panel row connection kit
Connection kit for connecting two rows of collectors one above the other.
Consisting of solar panel mounting material, equipotential bonding clamps,
end caps, connecting brackets and 1m thermally insulated piping
162035-RTX
£65.00
EKSRCRP
Brick red
£154.00
EKSRCAP
Anthracite
£154.00
162037-RTX
£100.00
Note: 1
64732 was EKSCON15
164733 was EKSCON20
Solar connection pipe extension
Ready to plug in, including fitting materials and connection fittings.
Available in 2.5, 5 and 10m lengths
Note: 1
64261-RTX was EKSCONX25
164262-RTX was EKSCONX50
164263 was EKSCONX100
HEATING
Maximum possible length of the connection pipe
Number of solar panels
Max. length
2
3
4
5
45m
30m
17m
15m
Solar flow pipe extension (15mm)
UV resistant thermally insulated, length L = 8m, including cable connection fitting
for the solar panel sensor line
Note: Was EKSCONXV80
Note: Was EKSCONRVP
Hydraulic connection kit (on-roof)
Connection kit for drainback (on-roof ), includes connection to solar panel,
pitched roof flashing, 2m UV resistant insulation, solar panel temperature sensor
and endcaps
Available in Anthracite or Brick red
Hydraulic connection kit (in-roof)
Connection kit for drainback (in-roof ), includes connection to solar panel,
solar panel temperature sensor and endcaps
140
Residential, Commercial and Industrial
Daikin Solar Thermal System
Solar Drainback Accessories
(Continued)
Description
Part number
Trade Price
Hydraulic connection kit (flat roof)
Connection kit for drainback (flat roof ), includes connection to solar panel,
flat roof penetration, 8.5m UV resistant insulation and solar panel temperature sensor
162038-RTX
£194.00
Gravity break set
Avoids thermal heat loss from thermal store due to thermo-siphon effect.
Advised when piping from heat exchanger is not making a down ward bend at the tank
165070
£8.00
Solar flow setter
Flow regulating valve with flow indicator (2-16 l/min). For balancing solar flow
in cascade thermal store installations
164102-RTX
£53.00
165113
£79.00
Note: For use only with EKHWP* only
Secondary circulation kit
Connection kit for secondary hot water connections
HEATING
Note: For use with EKHWP* only
Daikin Solar Thermal System
Thermal Store for Daikin Altherma High and Low Temperature
This is a hot water thermal storage tank and provides instantaneous hot water.
The tank serves as a heat storage medium. It can be heated by both Daikin Altherma heat pumps and solar energy, available for both
drainback and pressurised applications.
Description
Part number
Trade Price
EKHWP300B with connection kit for ERSQ011-016
EKHWP300B + EKEPHT3H
£1,159.00
EKHWP500B with connection kit for ERSQ011-016
EKHWP500B + EKEPHT5H
£1,409.00
EKHWP300B with connection kit for ERLQ004-008 & EDLQ05-07 and 3kW immersion heater
EKHWP300B +
EKDVCPLT3HX + EKBH3S
£1,315.00
EKHWP500B with connection kit for ERLQ011-016 & E(D/B)HQ014-D16 and 3kW immersion heater
EKHWP500B +
EKDVCPLT5H + EKBH3S
£1,595.00
EKHWP300PB with connection kit for ERSQ011-016
EKHWP300PB + EKEPHT3H
£1,247.00
EKHWP500PB with connection kit for ERSQ011-016
EKHWP500PB + EKEPHT5H
£1,587.00
EKHWP300PB with connection kit for ERLQ004-008 & EDLQ005-07 and 3kW immersion heater
EKHWP300PB +
EKDVCPLT3HX + EKBH3S
£1,403.00
EKHWP500PB with connection kit for ERLQ011-016 & E(D/B)HQ014-016 and 3kW immersion heater
EKHWP500PB +
EKDVCPLT5H + EKBH3S
£1,773.00
Connection elbow enables easy filling and draining of the storage tank
165210
£21.00
165215
£23.00
Drainback Solar Thermal store (EKHWP***B) Combination with Daikin Altherma HT
Drainback Solar Thermal store (EKHWP***B) Combination with Daikin Altherma LT & MB
Pressurised Solar Thermal store (EKHWP***PB) Combination with Daikin Altherma HT
Pressurised Solar Thermal store (EKHWP***PB) Combination with Daikin Altherma LT & MB
Note: It is recommended that 165210 and 165215 are ordered with every thermal store
Fill and drain connection
Note: It is recommended that 165210 and 165215 are ordered with every thermal store
Price List 2016
141
Daikin Solar Thermal System
Solar Standalone Accessories
The standalone pressurised solar system is designed for use with auxiliary gas boiler and twin coil cylinder.
Available in predefined on-roof and in-roof packs (see page 148)
Description
Part number
Trade Price
Solar panel (vertical) – small
(2006 x 1006 x 85mm), aperture area 1.79m2, weight 35kg, water content 1.3 L. Max. 6 bar
EKSV21P
£338.00
Mounting rail for small panels
Consisting of mounting profile rails and securing ties
162066
£24.00
162036-RTX
£69.00
164723
£40.00
Pump station
Consisting of: Pipe connection (diameter 22mm) including pipe compression fittings
and support sleeves (5x), flow regulator with 2 x KFE valves, integrated air separator,
ball valves with integrated backflow preventor, Grundfos UPM3 Solar 25-75 pump,
safety group with pressure gauge, including insulation and mounting accessories
EKSRDS2A
£284.00
Hydraulic connection kit (pressurised)
Connection kit for pressurised only, includes connection to solar panel,
2m UV resistant heat insulation for the external area, solar panel temperature sensor
and endcaps
EKSRCP
£112.00
Solar controller for standalone solar
Wall mounted, small and compact. Easy to use solar controller with back-lit
graphical illuminated display. Auxiliary heat source timer and pump speed control
UK.SOLCTRBS4
£191.00
FKU-HWS200TC
200L
£500.00*
FKU-HWS250TC
250L
£525.00*
FKU-HWS300TC
300L
£570.00*
Note: Was 162013
4x Support hooks for high profile tiles
4 double height-adjustable roof ties including fixing material for one solar panel
Note: Was EKSFIXADP
4x Support hooks for flat tiles (slate)
4 roof ties for flat roofing, e.g. slate, for one solar panel
HEATING
Note: Was EKSFIXADS
Note: To control auxiliary gas boiler only
Twin coil solar cylinder
Unvented stainless steel cylinder. Designed for gas boiler auxiliary heating and
solar hot water connections. Delivered with full G3 compliance kit including
2-port motorised valve (except expansion vessel - field supply)
Note: Further standalone solar components are available to complete the standalone system (see pages 137-139)
* Special offer price
142
Residential, Commercial and Industrial
Selecting the right Solar System
Daikin has a full range of solar thermal solutions including Drainback and Pressurised solutions to suit many installation requirements.
Solar systems are available to work with heat pumps or with boilers and offer enhanced DHW energy savings.
Use the table below to help select the right kind of solar system for your Daikin heat pump or your existing boiler.
Auxiliary heat source
Drainback
Pressurised
HT, LT & Hybrid Heat Pump
HT, LT & Hybrid
Heat Pump
Boiler
Thermal Store
Thermal Store
Twin coil
(EKHWP-B)
(EKHWP-PB)
(FKU)
Tank
Vertical
2.6m2
Vertical
2.0m2
Vertical
2.6m2
Horizontal
2.6m2
HEATING
Solar system
Vertical
2.0m2
Panel orientation
and size
On-roof
3
(page 145)
In-roof
Flat roof
3
3
(page 148)
3
(page 145)
(page 148)
3
7
(page 145)
3
(page 146)
3
(page 147)
3
(page 147)
3
3
(page 146)
(page 148)
7
(page 148)
3
(page 147)
3
7
Price List 2016
143
Selecting the right Solar Pack
Daikin offer solar systems in ready to order packs with all the key components include.
After deciding between drainback or pressurised solar, use this table to select the right solar pack for your project.
Daikin Solar Thermal System
HEATING
Solar Packs – Quick Selection Table
System type
Orientation
Fixing type
Tile
Roof cowl
1 panel pack
2 panel pack
3 panel pack
4 panel pack
5 panel pack
Drainback
Vertical
On-roof
Profiled tile
Anthracite
UK.SP1VPDBA
UK.SP2VPDBA
UK.SP3VPDBA
UK.SP4VPDBA
UK.SP5VPDBA
Slate/flat tile
Anthracite
UK.SP1VSDBA
UK.SP2VSDBA
UK.SP3VSDBA
UK.SP4VSDBA
UK.SP5VSDBA
Profiled tile
Red
UK.SP1VPDBR
UK.SP2VPDBR
UK.SP3VPDBR
UK.SP4VPDBR
UK.SP5VPDBR
Slate/flat tile
Red
UK.SP1VSDBR
UK.SP2VSDBR
UK.SP3VSDBR
UK.SP4VSDBR
UK.SP5VSDBR
In-roof
Profiled/slate/
flat tile
-
-
UK.SP2VIDBA
UK.SP3VIDBA
UK.SP4VIDBA
UK.SP5VIDBA
Flat-roof
-
-
UK.SP1VADBA
UK.SP2VADBA
UK.SP3VADBA
UK.SP4VADBA
UK.SP5VADBA
On-roof
Profiled tile
-
UK.SP1VPP
UK.SP2VPP
UK.SP3VPP
-
-
Slate/flat tile
-
UK.SP1VSP
UK.SP2VSP
UK.SP3VSP
In-roof
Profiled/slate/
flat tile
-
-
UK.SP2VIP
UK.SP3VIP
Flat-roof
-
-
UK.SP1VAP
UK.SP2VAP
UK.SP3VAP
On-roof
Profiled tile
-
UK.SP1HPP
UK.SP2HPP
UK.SP3HPP
Slate/flat tile
-
UK.SP1HSP
UK.SP2HSP
UK.SP3HSP
Flat-roof
-
-
UK.SP1HAP
UK.SP2HAP
UK.SP3HAP
On-roof
Profiled tile
-
UK.V21PP1
UK.V21PP2
UK.V21PP3
-
-
Slate/flat tile
-
UK.V21SP1
UK.V21SP2
UK.V21SP3
Profiled/slate/
flat tile
-
-
UK.V21IP2
UK.V21IP3
Pressurised
Vertical
Horizontal
Pressurised
(Standalone)
Vertical
In-roof
144
Residential, Commercial and Industrial
Daikin Solar Thermal System
Vertical on-roof profiled tile pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Roof brackets for concrete / profiled x 4
Mounting rail for panel
Hydraulic connection kit (on-roof )
including cowl in either:
Solar controller & pump station*
Coupling kit for multiple panels
Connection cable to disable heat pump
Pack price
Part number
Anthracite / Red
EKSRPS4A
162016-RTX
164110-RTX
Vertical on-roof slate tile pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Roof brackets for slate / flat tiles x 4
Mounting rail for panel
Hydraulic connection kit (on-roof )
including cowl in either:
Solar controller & pump station*
Coupling kit for multiple panels
Connection cable to disable heat pump
Pack price
Vertical in-roof pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Mounting rail for panel
Hydraulic connection kit (in-roof )
Solar controller & pump station*
Coupling kit for multiple panels
In-roof kit for 2x vertical panels
In-roof extension kit for 1x panel
Connection cable to disable heat pump
Pack price
Vertical flat roof pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Mounting rail for panel
Hydraulic connection kit (flat roof )
including flat roof penetration
Solar controller & pump station*
Coupling kit for multiple panels
Solar flat roof kit for 2xV26P
Solar flat roof kit for additional V26P
Connection cable to disable heat pump
Pack price
EKSV26P
162036-RTX
162067
EKSRCAP / EKSRCRP
Part number
Anthracite / Red
1 panel pack
2 panel pack
3 panel pack
4 panel pack
5 panel pack
UK.SP1VPDBA/R
Quantity
1
1
1
1
UK.SP2VPDBA/R
Quantity
2
2
2
1
UK.SP3VPDBA/R
Quantity
3
3
3
1
UK.SP4VPDBA/R
Quantity
4
4
4
1
UK.SP5VPDBA/R
Quantity
5
5
5
1
1
0
1
£1,084.00
1
1
1
£1,622.00
1
2
1
£2,160.00
1
3
1
£2,698.00
1
4
1
£3,236.00
1 panel pack
2 panel pack
3 panel pack
4 panel pack
5 panel pack
UK.SP1VSDBA/R
Quantity
1
1
1
1
UK.SP2VSDBA/R
Quantity
2
2
2
1
UK.SP3VSDBA/R
Quantity
3
3
3
1
UK.SP4VSDBA/R
Quantity
4
4
4
1
UK.SP5VSDBA/R
Quantity
5
5
5
1
EKSRPS4A
162016-RTX
164110-RTX
1
0
1
£1,055.00
1
1
1
£1,564.00
1
2
1
£2,073.00
1
3
1
£2,582.00
1
4
1
£3,091.00
Part number
1 panel pack
2 panel pack
3 panel pack
4 panel pack
5 panel pack
Quantity
-
UK.SP2VIDBA/R
Quantity
2
2
1
1
1
1
0
1
£1,686.00
UK.SP3VIDBA/R
Quantity
3
3
1
1
2
1
1
1
£2,354.00
UK.SP4VIDBA/R
Quantity
4
4
1
1
3
1
2
1
£3,022.00
UK.SP5VIDBA/R
Quantity
5
5
1
1
4
1
3
1
£3,690.00
EKSV26P
164723
162067
EKSRCAP / EKSRCRP
EKSV26P
162067
162037-RTX
EKSRPS4A
162016-RTX
162019
162020
164110-RTX
Part number
1 panel pack
2 panel pack
3 panel pack
4 panel pack
5 panel pack
EKSV26P
162067
162038-RTX
UK.SP1VADBA/R
Quantity
1
1
1
UK.SP2VADBA/R
Quantity
2
2
1
UK.SP3VADBA/R
Quantity
3
3
1
UK.SP4VADBA/R
Quantity
4
4
1
UK.SP5VADBA/R
Quantity
5
5
1
1
0
1
0
1
£1,437.00
1
1
1
0
1
£1,906.00
1
2
1
1
1
£2,527.00
1
3
1
2
1
£3,148.00
1
4
1
3
1
£3,769.00
EKSRPS4A
162016-RTX
162058
162059
164110-RTX
Important:
When installing an Daikin Altherma heat pump and Daikin drainback solar system, the following accessories need to be ordered separately:
EKHWP-B – Thermal store
EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB), not applicable for EDLQ-CV3
EKSCON*** – Solar connection pipe
*When installing an integrated ROTEX Gas Compact Unit and Daikin drainback solar system, order 164126 instead of EKSRPS4A
Price List 2016
145
HEATING
Solar Packs – Drainback System for Daikin Altherma
Daikin Solar Thermal System
Solar Packs – Pressurised System for Daikin Altherma
Vertical on-roof profiled tile pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Roof brackets for concrete / profiled tiles x 4
Mounting rail for panel
Hydraulic connection kit
Solar controller
Solar pump station
Flow sensor
Solar fluid (20 litres)
Coupling kit for multiple panels
Solar expansion vessel (25 litres)
Connection cable to disable heat pump
Pack price
Vertical on-roof slate / flat tile pack
HEATING
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Roof brackets for slate / flat tiles x 4
Mounting rail for panel
Hydraulic connection kit
Solar controller
Solar pump station
Flow sensor
Solar fluid (20 litres)
Coupling kit for multiple panels
Solar expansion vessel (25 litres)
Connection cable to disable heat pump
Pack price
Horizontal on-roof profiled tile pack
Horizontal pack order reference
This pack contains:
Horizontal flat plate collector
Roof brackets for concrete / profiled tiles x 4
Mounting rail for panel
Hydraulic connection kit
Solar controller
Solar pump station
Flow sensor
Solar fluid (20 litres)
Coupling kit for multiple panels
Solar expansion vessel (25 litres)
Connection cable to disable heat pump
Pack price
Horizontal on-roof slate / flat tile pack
Horizontal pack order reference
This pack contains:
Horizontal flat plate collector
Roof brackets for slate/flat tiles x 4
Mounting rail for panel
Hydraulic connection kit
Solar controller
Solar pump station
Flow sensor
Solar fluid (20 litres)
Coupling kit for multiple panels
Solar expansion vessel (25 litres)
Connection cable to disable heat pump
Pack price
Part number
EKSV26P
162036-RTX
162067
EKSRCP
162084
EKSRDS2A
164116
162052-RTX
162016-RTX
162050
164110-RTX
Part number
EKSV26P
164723
162067
EKSRCP
162084
EKSRDS2A
164116
162052-RTX
162016-RTX
162050
164110-RTX
Part number
EKSH26P
162036-RTX
162068
EKSRCP
162084
EKSRDS2A
164116
162052-RTX
162016-RTX
162050
164110-RTX
Part number
EKSH26P
164723
162068
EKSRCP
162084
EKSRDS2A
164116
162052-RTX
162016-RTX
162050
164110-RTX
1 panel pack
2 panel pack
3 panel pack
UK.SP1VPP
Quantity
1
1
1
1
1
1
1
1
0
1
1
£1,302.00
UK.SP2VPP
Quantity
2
2
2
1
1
1
1
1
1
1
1
£1,840.00
UK.SP3VPP
Quantity
3
3
3
1
1
1
1
1
2
1
1
£2,378.00
1 panel pack
2 panel pack
3 panel pack
UK.SP1VSP
Quantity
1
1
1
1
1
1
1
1
0
1
1
£1,273.00
UK.SP2VSP
Quantity
2
2
2
1
1
1
1
1
1
1
1
£1,782.00
UK.SP3VSP
Quantity
3
3
3
1
1
1
1
1
2
1
1
£2,291.00
1 panel pack
2 panel pack
3 panel pack
UK.SP1HPP
Quantity
1
1
1
1
1
1
1
1
0
1
1
£1,325.00
UK.SP2HPP
Quantity
2
2
2
1
1
1
1
1
1
1
1
£1,886.00
UK.SP3HPP
Quantity
3
3
3
1
1
1
1
1
2
1
1
£2,447.00
1 panel pack
2 panel pack
3 panel pack
UK.SP1HSP
Quantity
1
1
1
1
1
1
1
1
0
1
1
£1,296.00
UK.SP2HSP
Quantity
2
2
2
1
1
1
1
1
1
1
1
£1,828.00
UK.SP3HSP
Quantity
3
3
3
1
1
1
1
1
2
1
1
£2,360.00
Important:
When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately:
EKHWP-PB - Thermal store
1620** – Solar pressurised pipe and connectors
EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB), not applicable for EDLQ-CV3
146
Residential, Commercial and Industrial
Daikin Solar Thermal System
Vertical in-roof pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Mounting rail for panel
Hydraulic connection kit
Solar controller
Solar pump station
Flow sensor
Solar fluid (20 Litres)
Coupling kit for multiple panels
In roof kit for 2 x V26P
In roof extension kit for additional V26P
Solar expansion vessel (25 litres)
Connection cable to disable heat pump
Pack price
Vertical flat roof pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector
Mounting rail for panel
Hydraulic connection kit
Solar controller
Solar pump station
Flow sensor
Solar fluid (20 Litres)
Coupling kit for multiple panels
Solar flat roof kit for 2xV26P
Solar flat roof kit for additional V26P
Solar expansion vessel (25 litres)
Connection cable to disable heat pump
Pack price
Horizontal flat roof pack
Horizontal pack order reference
This pack contains:
Horizontal flat plate collector
Mounting rail for panel
Hydraulic connection kit
Solar controller
Solar pump station
Flow sensor
Solar fluid (20 Litres)
Coupling kit for multiple panels
Solar flat roof kit for H26P
Solar flat roof kit for additional H26P
Solar expansion vessel (25 litres)
Connection cable to disable heat pump
Pack price
Part number
EKSV26P
162067
EKSRCP
162084
EKSRDS2A
164116
162052-RTX
162016-RTX
162019
162020
162050
164110-RTX
Part number
EKSV26P
162067
EKSRCP
162084
EKSRDS2A
164116
162052-RTX
162016-RTX
162058
162059
162050
164110-RTX
Part number
EKSH26P
162068
EKSRCP
162084
EKSRDS2A
164116
162052-RTX
162016-RTX
162060
162061
162050
164110-RTX
(Continued)
2 panel pack
3 panel pack
UK.SP2VIP
Quantity
2
2
1
1
1
1
1
1
1
0
1
1
£1,958.00
UK.SP3VIP
Quantity
3
3
1
1
1
1
1
2
1
1
1
1
£2,626.00
1 panel pack*
2 panel pack
3 panel pack
UK.SP1VAP
Quantity
1
1
1
1
1
1
1
0
1
0
1
1
£1,615.00
UK.SP2VAP
Quantity
2
2
1
1
1
1
1
1
1
0
1
1
£2,084.00
UK.SP3VAP
Quantity
3
3
1
1
1
1
1
2
1
1
1
1
£2,705.00
1 panel pack
2 panel pack
3 panel pack
UK.SP1HAP
Quantity
1
1
1
1
1
1
1
0
1
0
1
1
£1,437.00
UK.SP2HAP
Quantity
2
2
1
1
1
1
1
1
1
1
1
1
£2,054.00
UK.SP3HAP
Quantity
3
3
1
1
1
1
1
2
1
2
1
1
£2,671.00
HEATING
Solar Packs – Pressurised System for Daikin Altherma
* Important:
When ordering the vertical flat roof pack, please be aware the solar flat roof kit is sufficient for two vertical panels,
thus some wastage will occur (the wastage is not enough to be used for another panel).
Important:
When installing an integrated Daikin Altherma heat pump and pressurised Daikin solar thermal system, the following accessories need to be ordered separately:
EKHWP-PB - Thermal store
1620** – Solar pressurised pipe and connectors
EKRP1HBA – Option PCB for use with Hydrobox for alarm monitoring (Solar priority PCB), not applicable for EDLQ-CV3
Price List 2016
147
Daikin Solar Thermal System
Solar Packs – Standalone Pressurised System for use with Auxiliary Gas Boiler
Vertical on-roof profiled tile pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector (small panel)
Roof brackets for concrete / profiled tiles x 4
Mounting rail for panel
Hydraulic connection kit
Solar controller (for auxiliary gas boiler)
Solar pump station
Solar fluid (20 litres)
Coupling kit for multiple panels
Solar expansion vessel (25 litres)
Pack price
Vertical on-roof slate / flat tile pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector (small panel)
Roof brackets for slate / flat tiles x 4
Mounting rail for panel
Hydraulic connection kit
Solar controller (for auxiliary gas boiler)
Solar pump station
Solar fluid (20 litres)
Coupling kit for multiple panels
Solar expansion vessel (25 litres)
Pack price
HEATING
Vertical in-roof pack
Vertical pack order reference
This pack contains:
Vertical flat plate collector (small panel)
Mounting rail for panel
Hydraulic connection kit
Solar controller (for auxiliary gas boiler)
Solar pump station
Solar fluid (20 litres)
Coupling kit for multiple panels
Solar expansion vessel (25 litres)
In roof kit for 2 x V21P
In roof extension kit for additional V21P
Pack price
Part number
EKSV21P
162036-RTX
162066
EKSRCP
UK.SOLCTRBS4
EKSRDS2A
162052-RTX
162016-RTX
162050
Part number
EKSV21P
164723
162066
EKSRCP
UK.SOLCTRBS4
EKSRDS2A
162052-RTX
162016-RTX
162050
Part number
EKSV21P
162066
EKSRCP
UK.SOLCTRBS4
EKSRDS2A
162052-RTX
162016-RTX
162050
162017
162018
1 panel pack
2 panel pack
3 panel pack
UK.V21PP1
Quantity
1
1
1
1
1
1
1
0
1
£1,144.00
UK.V21PP2
Quantity
2
2
2
1
1
1
1
1
1
£1,610.00
UK.V21PP3
Quantity
3
3
3
1
1
1
1
2
1
£2,076.00
1 panel pack
2 panel pack
3 panel pack
UK.V21SP1
Quantity
1
1
1
1
1
1
1
0
1
£1,115.00
UK.V21SP2
Quantity
2
2
2
1
1
1
1
1
1
£1,552.00
UK.V21SP3
Quantity
3
3
3
1
1
1
1
2
1
£1,989.00
2 panel pack
3 panel pack
UK.V21IP2
Quantity
2
2
1
1
1
1
1
1
1
0
£1,898.00
UK.V21IP3
Quantity
3
3
1
1
1
1
2
1
1
1
£2,485.00
Important:
Packs detailed above are not designed to be used with Daikin Altherma heat pumps.
The above packs are designed to be used with an auxiliary gas boiler and twin coil cylinder.
To complete the Daikin standalone pressurised solar system, please order twin coil cylinder (FKU-HWS***TC).
148
Residential, Commercial and Industrial
HEATING
Underfloor Heating
ROTEX underfloor heating system is designed to work seamlessly
with the Daikin Altherma range to provide high heat pump efficiency
and low surface temperatures for the most comfortable room climate.
When partnered with heat pumps, UFH with low flow temperatures
helps to achieve high heat pump efficiencies and even higher
running cost savings.
> Energy saving and highly versatile, can be used with heat pumps and condensing boilers
> Simple installation with easy to lay components
> Additional energy benefits recognised in SAP and MCS
> R
otex Monopex is ideal for low temperature systems such as heat pumps and is
available in a variety of pipe sizes
> R
otex System 70 is ideal for mixed UFH and radiator systems and commercial heating
systems with primary flow temperatures 55 - 70°C
For information on Daikin’s underfloor heating design process go to page 152.
Price List 2016
149
Underfloor Heating System
Heat Emission Plate
Dual channel aluminium spreader plates for timber suspended or battened floor installations.
For joists at 400mm centres. Plate dimensions 1000x390mm
Description
Length
Part number
Trade Price
Spreader plates
For Ø 17mm pipe
10
(3.9m2)
171141
£67.00
Underfloor Heating System
Underfloor Heating Pipes
HEATING
Monopex heating pipes: Thick-walled, linked basic PE-X pipe with oxygen-tight barrier for Monopex low temperature underfloor heating systems.
Description
Length
Part number
Trade Price
Monopex 14 PE-X 14 x 2 OD
For Monopex underfloor
heating system
120m
170008
£128.00
240m
170009
£255.00
Monopex 14 ALU thick-walled PE-X 14 x 2 OD
Aluminium coating and PE external layer.
For Monopex underfloor heating systems
120m
170604
£181.00
240m
170605
£360.00
Monopex 17 PE-X 17 x 2 OD
For Monopex underfloor
heating system
120m
170029
£142.00
240m
170028
£283.00
600m
170062
£705.00
120m
170030
£163.00
240m
170109
£325.00
400m
170108
£540.00
25m
170053
Ø 19/25mm
£15.00
25m
170098
Ø 16/21mm
£12.00
75m
170001
Ø 23/28mm
£47.00
120m
170068
£199.00
240m
170086
£398.00
120m
170601
£229.00
240m
170602
£457.00
200m
170050
£435.00
Monopex 20 PE-X 20 x 2 OD
For Monopex underfloor
heating system
Protective pipe
Black corrugated pipe made of plastic as additional
insulation in the area of the manifold and expansion joints
DUO heating pipes: Thick-walled linked PE-X basic pipe, with oxygen-tight barrier, and additional highly flexible PE ribbed pipe.
For underfloor heating systems operated in direct combination with other heating surfaces, e.g. radiators.
DUO 17 PE-X 17/12 x 2 OD
For system 70 underfloor heating
& heating radiator connection
Outer pipe Ø 17mm
Inner pipe 12 x 2mm
DUO 17 ALU PE-X 17/12 x 2 OD
With aluminium coating and PE external layer.
For system 70 radiator connection and underfloor heating
Outer pipe Ø 17mm
Inner pipe 12 x 2mm
DUO 25 PE-X 25/18 x 2 OD
For system 70 industrial underfloor heating
150
Residential, Commercial and Industrial
Underfloor Heating System
Manifolds
RMX manifold: RMX heating circuit manifold, for underfloor heating systems and radiators.
Suitable for the smallest fitting heights. Buy clamping ring sets separately to suit pipe.
Description
Quantity per pack
Part number
Trade Price
Manifold RMX 2-port
1
172702
£106.00
Manifold RMX 3-port
1
172703
£124.00
Manifold RMX 4-port
1
172704
£146.00
Manifold RMX 5-port
1
172705
£167.00
Manifold RMX 6-port
1
172706
£189.00
Manifold RMX 7-port
1
172707
£211.00
Manifold RMX 8-port
1
172708
£232.00
Manifold RMX 9-port
1
172709
£254.00
Manifold RMX 10-port
1
172710
£276.00
Manifold RMX 11-port
1
172711
£296.00
Manifold RMX 12-port
1
172712
£319.00
RMX actutator (230V)
Actuator for RMX manifold and kombi box
1
175145
£18.00
RMX connection set DUO17
2
170312
£8.00
RMX connection set Monopex 14
2
170314
£8.00
RMX connection set Monopex 17
2
170317
£7.00
RMX connection set DUO25
2
170318
£7.00
RMX connection set Monopex 20
2
170320
£7.00
RMX manifold isolating valves 1”
2
175514
£21.00
HEATING
Clamping ring set on RMX heating circuit manifold for flow and return per heating circuit
HKV manifold: HKV heating circuit manifold, suitable for underfloor heating and radiators, with fast mounting system.
Description
Quantity per pack
Part number
Trade Price
Manifold HKV 2-port
1
172502
£72.00
Manifold HKV 3-port
1
172503
£87.00
Manifold HKV 4-port
1
172504
£103.00
Manifold HKV 5-port
1
172505
£116.00
Manifold HKV 6-port
1
172506
£137.00
Manifold HKV 7-port
1
172507
£147.00
Manifold HKV 8-port
1
172508
£162.00
Manifold HKV 9-port
1
172509
£176.00
Manifold HKV 10-port
1
172510
£192.00
Manifold HKV 11-port
1
172511
£206.00
Manifold HKV 12-port
1
172512
£223.00
Manifold HKV 13-port
1
172513
£237.00
Manifold HKV 14-port
1
172514
£291.00
HKV actuator (230V)
Actuator for HKV manifold and kombi box
1
175110
£21.00
HKV connection set DUO17
2
177012
£7.00
HKV connection set Monopex 14
2
177014
£7.00
HKV connection set Monopex 17
2
177017
£7.00
HKV connection set DUO25
2
177018
£7.00
HKV connection set Monopex 20
2
177020
£8.00
Connection kit for HKV2 to HKV14
Contains 2 x isolating valves (1”),
2 x connection pieces,
2 x filling and draining valves and
2 x temperature gauges
1
175510
£68.00
Clamping ring set on HKV heating circuit manifold for flow and return, per heating circuit
Price List 2016
151
Underfloor Heating System
Manifold Accessories
Quantity per pack
Part number
Trade Price
Coupling nipple (3/4”) for combination
with 1703** clamping ring sets
2
177227
£8.00
Connection nipple (3/4” PEX x 1/2” male)
for combination with 1703** clamping ring sets
2
177327
£6.00
Manifold cabinet up to 7-port
1
174110
£126.00
Manifold cabinet up to 10-port
1
174115
£139.00
Manifold cabinet up to 14-port
1
174120
£159.00
Kombi box
Subdivision for distribution room-by-room and controller
for max. 2 underfloor heating circuits with system 70
for DUO 17 heating pipe and optionally with a radiator
complete in UP case incl. cover plates, without clamping
ring set and actuator
1
172415
£95.00
HEATING
Description
Underfloor Heating (UFH) System Design Process
To prepare an accurate bill of materials
and quotation for your underfloor heating
project, we need to carry out a detailed
UFH system design. This will take account of
parameters including room heat losses, water
flow temperature, floor construction, floor
coverings and preferred manifold positions.
152
Residential, Commercial and Industrial
If you require an UFH system design, please contact your sales
representative or your local branch for assistance. To enable
us to carry out the UFH design, you will need to submit:
> Autocad drawings – floor plans and elevations
> Completed Daikin UFH design request form
(available from your local branch)
Please allow up to 20 working days from submitting your
drawings to receiving your quotation.
Once you have placed an order for the UFH materials, we will
send you the UFH system design for your approval prior to
shipping the materials.
Underfloor Heating System
Insulating Strips and Installation Accessories
Quantity per pack
Part number
Trade Price
Tacker gun
Tacker gun for 60mm pipe staples.
The tacker gun can be used to secure pipe directly to
floor insulation
1
171134
£200.00
Pipe staples
60mm pipe staples for use with tacker gun (171134)
and high density insulation with DPM
300
171137
£35.00
Clip rail
1m pieces, pipe centres 50mm
100
171224
£271.00
Clip rail nail KN06
100
171127
£27.00
Edging strip
For cement or anhydrite screed.
PE foam with welded foil, height 150mm, 8mm thick
25m
171101
£16.00
Edging strip
For free-flowing screed PE foam
with welded foil, and additional sealing cord.
Height 150mm, 10mm thick
25m
171126
£30.00
Combined pipe cutters and stripping pliers RAZ1
1
171110
£53.00
Pipe decoiler RAW 240 for <240m
1
171006
£525.00
Pipe clips
50
171117
For Ø 17-20mm
£6.00
171125
For Ø 25mm
£9.00
171142
For Ø 14-18mm
£16.00
171143
For Ø 20-22mm
£20.00
Pipe bend
This is recommended to facilitate the bend of the pipe
up-to the manifold
HEATING
Description
10
Price List 2016
153
Underfloor Heating System
Underfloor Heating Room Controls Basic Range
HEATING
Note: Cannot be combined with advanced range (see page 155)
Description
Quantity per pack
Part number
Trade Price
RTR5 control
Electronic room temperature control (230V)
1
175117
£21.00
RTK control
Room temperature control with heating/cooling function
1
175125
£30.00
FRT wireless control
Wireless room temperature control
1
175120
£77.00
Single FRT wireless receiver
Receiver FEM1 for 1x FRT
1
175121
£86.00
Multiple FRT wireless receiver
Receiver FEM4 for 4x FRT
1
175122
£152.00
Underfloor Heating System
Wiring Centres and Accessories Basic Range
Note: Cannot be combined with advanced range (see page 155)
Description
Quantity per pack
Part number
Trade Price
Wiring box for 14x SAT
Wiring box 6xRTR and max 14xSAT
DIN rail field supplied
1
175131
£62.00
Wiring box extension for 4x SAT
Wiring box extension for 175131.
Additional 2xRTR and Max 4x SAT
DIN rail field supplied
1
175132
£26.00
Pump module for wiring box
Provides on/off signal to the heat source
1
175134
£62.00
Note: Can only be combined with wiring box 175131.
One required per UFH manifold
DIN rail field supplied
154
Residential, Commercial and Industrial
Underfloor Heating System
Underfloor Heating Room Controls Advanced Range
Modern aesthetics, easy to install and greater user comfort
Note: Cannot be combined with basic range (see page 154)
Description
Quantity per pack
Part number
Trade Price
Room thermostat (wired)
- Electronic room temperature control (5V)
- Adjustment range 5-26°C
- D
isplay of heating and cooling mode (red and blue LED)
1
175139
£27.00
Room thermostat (RF)
- Electronic room temperature control
- Adjustment range 5-26°C
- Solar powered (no batteries required)
- A
llow 24 hours to charge before commissioning
1
175142
£128.00
Underfloor Heating System
Wiring Centres and Accessories Advanced Range
Modern aesthetics, easy to install and greater user comfort
Description
Quantity per pack
Part number
Trade Price
Wiring centre
- 6 channels
- 4 actuators (230 V) per channel
- Automatic heating/cooling switchover
DIN rail field supplied
1
175140
£121.00
Wiring centre
- 2 channels
- 4 actuators (230 V) per channel
- Automatic heating/cooling switchover
DIN rail field supplied
1
175141
£60.00
Wiring centre (RF)
- 6 channels
- 4 actuators (230 V) per channel
- Automatic heating/cooling switchover
- I ncluding antenna for wireless communication
DIN rail field supplied
1
175143
£227.00
Wiring centre (RF)
- 2 channels
- 4 actuators (230 V) per channel
- Automatic heating/cooling switchover
- I ncluding antenna for wireless communication
DIN rail field supplied
1
175144
£151.00
Wiring centre power module
To supply power to the wiring centres, including:
- P
ump input/output for heating and cooling
DIN rail field supplied
1
175137
£113.00
Wiring centre clock module
- Removable clock module
- 2 setback timers for heating circuits
1
175138
£60.00
Note: To be combined with the wiring centre power module
Price List 2016
155
HEATING
Note: Cannot be combined with basic range (see page 154)
HEATING
Heat Pump Convectors
Heat pump convectors can provide both heating and cooling if
required and can be used with the Daikin Altherma heat pump to
offer a compact and highly efficient solution:
> D
esigned to operate at low flow temperature (35°C) to optimise the
efficiency of an air-to-water heat pump
> Quiet operation and no draughts
> Able to heat and cool
> Available in 1.5 and 2kW
156
Residential, Commercial and Industrial
FWX / EKV
Daikin Heat Pump Convector
Indoor Unit
FWXV15A
FWXV20A
Description
Cased, low wall mount type, 2-pipe*
Cased, low wall mount type, 2-pipe*
EKVKHPC
EKVKHPC
£491.00
£528.00
1.5
1.2
0.98
0.013
0.013
2.0
1.7
1.4
0.015
0.015
Must be ordered with:
Combined Trade Unit Price
Heating capacity
Cooling capacity
Power input
Total capacity
Nom.
Total capacity
Nom.
Sensible capacity
Nom.
Heating
Nom.
Cooling
Nom.
Height x Width x Depth
Dimensions
Weight
Piping connections Drain/OD/Inlet/Outlet
Sound pressure level Heating
Nom.
Cooling
Nom.
Power supply
Phase/Frequency/Voltage
kW
kW
kW
kW
kW
mm
kg
mm/inch
dBA
dBA
Hz/V
600 x 700 x 210
15
18/G 1/2/G 1/2
19
19
29
29
1-phase / 230V / 50Hz
Nominal capacity based on following conditions:
Heating: indoor temp, 20°CDB; entering water temp. 45°C, water temperature drop 5°C.
Cooling: Indoor temp. 27°CDB; entering water temp. 7°C, water temperature rise 5°C.
Notes:
>The highly efficient, low noise Daikin heat pump convector is designed to provide the maximum comfort
and high efficiency in combination with Daikin Altherma heat pumps
>The heat pump convector improves system efficiency compared to a combined under floor heating
and radiator system and to a fan coil heating system
>The Daikin heat pump convector has been designed to work effectively at low temperatures,
while retaining a compact size compared to an equivalent output radiator sized for 45°C
>The heat pump convector can easily replace existing heat emitters
>The unit is very quiet in operation and is ideal for bedroom applications
>The unit has a quiet operation mode which can be selected using the remote controller
>The sound levels are as low as 18dB(A) on 2kW system and 12dB(A) on 1.5kW system on the quiet mode
>Daikin heat pump convectors offer a solution combined with UFH systems to provide heat in areas where
UFH is difficult to integrate
>It is designed to support heating only and heating / cooling applications
>When combined with Daikin Altherma outdoor units, the heat pump convectors can be linked together
for total system control, additional comfort and increased efficiency
>Additional third party controls are needed to link simple fan coil systems with Daikin Altherma heat pumps
>Delivered with individual controller and with 2-way valve
>Drain pan is included
i)* P
lease note that EKVKHPC (2 way valve)
needs to be ordered as a separate item,
but price shown includes the value of
this part
HEATING
Features:
Price List 2016
157
HEATING
Daikin UK Price List 2016
Refrigeration
Conveni-Pack (CVP)
160
Indoor Units and Biddle Air Curtains
161
Booster Unit
162
ZEAS163
Multi-ZEAS164
165
Industrial Condensing Units
166
REFRIGERATION
Accessories for ZEAS and Conveni-Pack
Scottish
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
LRYEQ-AY1
Conveni-Pack (CVP)
Conveni-Pack is a compact, low noise system which
integrates high and low temperature refrigeration
along with heating and cooling into one system.
It’s a total solution that helps retailers save energy
and reduce their environmental impact.
Benefits
> Optimum efficiency: inverter driven outdoor units match
system output to the actual demand in order to reach optimum
efficiency under all conditions
> Connection flexibility: supports a wide range of refrigeration
and cooling cases
> Save energy: by recovering the heat extracted from the
connected refrigeration appliances and using sophisticated
controls, energy savings of up to 50% can be reached compared
with conventional 3P systems
> Small footprint: along with reduced piping makes the compact
Conveni-Pack ideal for densely populated urban areas
> Flexible: VRV (Variable Refrigerant Volume) technology
for flexible application range. Full range of VRV fan coils
available together with air curtains
-35°C
HEAT
RECOVERY
> Minimal noise: lowest operating sound level
including night set back function
Medium temperature refrigeration & air conditioning
REFRIGERATION
Cooling capacity
Heating capacity (2)
Dimensions
Weight
Heat exchanger
Fan
Fan motor
Sound pressure
Compressor
Operation range
Refrigerant
Refrigerant oil
Piping connections
Power supply
Voltage range
Air conditioning
Refrigeration (1)
Air conditioning
Refrigeration (2)
Height x Width x Depth
Type
Type
Quantity
Air flow rate Cooling
Output
Drive
Nom. at 10m free field
N° of compressors
Type
Piston displacement
Speed
Output
Starting method
Frequency ON/OFF
Evaporator
Cooling
Type
Charge
Control
Type
Charged volume
Refrigeration Liquid
LRYEQ16AY1
Nom.
Nom.
Nom.
Nom.
kW
kW
kW
kW
mm
kg
Nom.
m³/sec
W
dBA
m³/h
rpm
W
Min.~Max.
50m or less
50~130m
Gas
50m or less
50~130m
Phase / Frequency / Voltage
Min.
Max.
-10°C
°CDB
kg
l
inch (mm)
inch (mm)
inch (mm)
inch (mm)
Hz / V
%
%
14.0
21.8
27.0
21.8
1,680 x 1,240 x 765
370
Cross fin coil
Propeller fan
2
3.833
750
Direct drive
42
3
Hermetically sealed scroll compressor
13.34 / 10.53 / 10.53
6,300 / 2,900 / 2,900
2,500 / 3,600 / 4,500
Direct on line (inverter driven)
Less than 6 times/hour
-20 @ 0~10
R-410A
11.5
Electronic expansion valve
Daphne FVC68D
1.7 (*1) / 2.1 (*2) / 2.1 (*3) / 4.0 (*4)
3/8 (9.5)
1/2 (12.70)
1 1/8 (28.60)
1 3/8 (34.90)
3~ / 50 / 380-415
-10
10
(1)Cooling priority mode: evaporating
temp. -10°C; outdoor temp. 32°CDB;
suction SH 10°C
(2)Heat recovery 100% mode: indoor
temp. 20°CDB; outdoor temp. 7°CDB,
6°CWB; refrigeration load 18kW; piping
length: 7.5m; level difference: 0m
(*1) Compressor 1
(*2) Compressor 2
(*3) Compressor 3
Trade Price
160
Residential, Commercial and Industrial
£14,015.00
(*4) Factory charge of unit
Indoor Units and Biddle Air Curtains
for Connection to Conveni-Pack
To respond to all shop requirements for comfort cooling and heating, a wide range of AC indoor units
and Biddle air curtains is available.
Capacity class (kW)
Product name
50
63
71
80
100
125
140
200
250
5.6
6.3
7.1
8.0
9.0
8.0
9.0
10.0
11.2
12.5
14.0
16.0
16.0
18.0
22.4
25.0
28.0
31.5


Page 56

Page 57
Roundflow cassette
FXFQ-A



2-way blow
ceiling mounted cassette
FXCQ-A



1-way blow
corner cassette

FXKQ-MA
See VRV
Section
Page 57
Concealed ceiling unit
(medium static)
FXSQ-A





Page 58
Concealed ceiling unit
(high static)
FXMQ-P7





Page 58
Concealed ceiling unit
(ultra high static)
FXMQ-MB
Ceiling suspended unit
FXHQ-A
Under ceiling cassette unit
FXUQ-A
Floor mounted cased
FXLQ-P


Page 62
Concealed
floor standing unit
FXNQ-A


Page 62




Page 60

Page 61

Page 61
REFRIGERATION
Model
Cooling capacity (kW)1
Heating capacity (kW)2
Please see Fan Coils on pages 56 to 62 for full product details and prices.
Capacity class (kW)
Model
Product Name
Heating capacity (kW)2
80
100
7.4 - 11.0 11.6 - 13.4
125
140
200
250
15.6
16.2 - 19.9
23.3
29.4 - 31.1
See VRV
Section
Biddle air curtain
free hanging
CYVS-DK






Pages 66 & 67
Biddle air curtain cassette
CYVM-DK






Pages 66 & 67
Biddle air curtain recessed
CYVL-DK






Pages 66 & 67
1
Nominal cooling capacities are based on: indoor temperature: 27°CDB / 19°CWB, outdoor temperature: 35°CDB, piping length: 7.5m, level difference: 0m
2
Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB / 6°CWB, piping length: 7.5m, level difference: 0m
3
Optional
Price List 2016
161
LCBKQ-AV19
Booster Unit
Benefits
> A
booster unit allows the connection of freezer showcases/
rooms to ZEAS and Conveni-Pack outdoor units
> R
educed piping requirements, from 4 to 2 pipes,
compared with a conventional system
> Low sound mode reduces sound emissions significantly
Booster with ZEAS:
MEDIUM + LOW TEMPERATURE refrigeration
-19°C
-20°C
8°C
2°C
Booster
Booster
Booster with Conveni-Pack:
MEDIUM + LOW TEMPERATURE refrigeration + space air conditioning + Biddle air curtain
-19°C
8°C
2°C
REFRIGERATION
Booster
Low Temperature Refrigeration
Nom.
Unit
Weight
Compressor
Unit
Type
Piston displacement
m³/h
Number of revolutions
rpm
Output
W
Starting method
Frequency ON/OFF
Type
Air flow rate
Cooling
Nom.
m³/min
Evaporator
Cooling
Min.~Max. °CDB
Ambient temperature Min.~Max.
°C
Type
Control
Type
Charged volume
l
Piping length
System
Booster unit - IU
Phase/Frequency/Voltage
Hz/V
Operation range
Refrigerant
Refrigerant oil
Piping connections
Power supply
Booster
LCBKQ3AV19
Refrigeration capacity
Dimensions
Fan
-20°C
Height
Width
Depth
Trade Price
kW
mm
mm
mm
kg
3.35
480
680
310
47
Hermetically sealed swing compressor
10.16
6,540
1,300
Direct on line (inverter driven)
Less than 6 times/hour
Propeller fan
1.6
-45~-20
-15~43
R-410A
Electronic expansion valve
Daphne FVC50K + FVC68D
0.85 / 0.5
30m or less
1~/50/220-240
£2,773.00
(1) Evaporating temp. -35°C; outdoor temp. 32°C; suction SH 10K; saturated temp. to discharge pressure of booster unit -10°C
(2) Its functioning relies on fluorinated greenhouse gases
162
Residential, Commercial and Industrial
LREQ-BY1
ZEAS Condensing Units
When you select a refrigeration condensing unit,
you want premium performance with simple
installation and maintenance. That’s why you
should specify Daikin ZEAS condensing units.
A complete solution for refrigeration applications
Compact yet powerful and extremely energy efficient, Daikin ZEAS
condensing units offer an industry-leading solution for all kinds of
installation projects.
ZEAS is an adaptable and controllable solution for all kinds of
environments with fluctuating loads such as supermarkets, hotels,
restaurants, hospitals and florists, as well as food production
facilities such as cold storage, and blast coolers and freezers.
Delivering all the benefits of inverter controlled VRV technology
for commercial refrigeration systems, ZEAS offers a comprehensive
product range suitable for low temperature applications of 5.4 to
15.1 kW at -35/+32°C and medium temperature applications of
12.2 to 37.0 kW at -10°C /+32°C.
Its small footprint and low sound levels offer installation
flexibility, so you can gain larger capacities even in small spaces.
What’s more, the ZEAS solution comes fully packaged and
Medium temperature
Nom.
Low temperature
Nom.
Unit
Height x Width x Depth
Unit
Type
Type
Quantity
Air flow rate
Cooling
Nom.
Fan motor
Output
Drive
Sound pressure Nom. at 10m free field
Compressor
Type
Piston displacement
Speed
Output
Starting method
Operation range Evaporator
Min.~Max.
Ambient temp.
Min.~Max.
Refrigerant
Type
Charge
Control
Refrigerant oil
Type
Charged volume
Piping
Liquid
50m or less
connections
50~130m
Gas
50m or less
50~130m
Power supply
Phase/Frequency/Voltage
Voltage range
Min.
Max.
Current
Nominal running
Compressor Cooling
current (RLA) - 50Hz
Current - 50Hz
Trade Price
Starting current (MSC)
Minimum Ssc value
Minimum circuit amps (MCA)
Maximum fuse amps (MFA)
Total overcurrent amps (TOCA)
Full load amps (FLA) Fan motor
All in all, it’s a quality solution that delivers maximum refrigeration
capacity with minimal fuss.
ZEAS condensing units offer:
> Compact 2P system with reduced piping lengths
> H
igher refrigeration capacity to power consumption ratio
compared with standard systems
> COP of up to 3.0
> Energy efficient inverter control minimises CO2 emissions
> Utilises energy efficient R-410A refrigerant
LREQ5BY1
LREQ6BY1
kW
kW
mm
kg
12.5
15.2
5.51
6.51
1,680 x 635 x 765
166
m³/sec
kW
1.583
dBA
m³/h
rpm
kW
°CDB
°C
kg
l
inch (mm)
inch (mm)
inch (mm)
inch (mm)
Hz/V
%
%
A
A
kVa
A
A
A
A
1.700
LREQ8BY1
LREQ10BY1
LREQ12BY1
19.8
8.33
23.8
10.0
1,680 x 930 x 765
242
Cross fin coil
Propeller fan
26.5
10.7
1
2.850
12.8
13.7
74
655
19.3
15
15.6
0.4
£5,921.00
£7,360.00
£8,855.00
LREQ20BY1
33.9
37.9
13.9
15.4
1,680 x 1,240 x 765
331
337
2
2.983
3.183
0.35
0.75
Direct drive
35.0
36.0
37.0
39.0
41.0
Hermetically sealed scroll compressor
11.18
13.85
19.68
23.36
25.27
5,280
6,540
4,320+2,900
6,060+2,900
6,960+2,900
2.6
3.2
2.1 + 3.6
3.0 + 3.6
3.4 + 3.6
Direct on line (inverter driven)
-45~10
-20~43
R-410A
5.2
7.9
Electronic expansion valve
Daphne FVC68D
1.7 / 2.5
1.7 / 2.5
1.7 / 2.1 / 3.0
1.7 / 2.1 / 3.0
1.7 / 2.1 / 3.0
3/8 (9.5)
3/8 (9.5)
1/2 (12.70)
7/8 (22.20)
1 1/8 (28.60)
7/8 (22.20)
1 1/8 (28.60)
3~/50/380-415
-10
10
7.1
9.2
5.3 + 7.5
7.4 + 7.9
9.8 + 8.3
-
LREQ15BY1
3.933
0.35 + 0.35
4.000
0.75+0.75
42.0
43.0
32.24
35.8
5,280+2,900+2,900 6,960+2,900+2,900
2.6 + 3.6 + 3.6 3.4 + 3.6 + 3.6
11.5
1.7 / 2.1 / 4.0
1/2 (12.70)
1.7 / 2.1 / 4.0
1 3/8 (34.90)
1 3/8 (34.90)
7.0 + 8.2 + 8.2
75
9.5 + 8.4 + 8.4
84
899
22.0
25
31.5
0.9
1,097
24.0
£10,850.00
£11,570.00
761
31.4
945
35.0
40
48.3
0.4 + 0.4
0.7 + 0.7
£16,531.00
£18,766.00
*Operation conditions of outdoor unit: Te = -10°C, outdoor temperature +32°C, suction SH10°C
Price List 2016
163
REFRIGERATION
MT or LT refrigeration condensing unit
Refrigeration
capacity
Dimensions
Weight
Heat exchanger
Fan
programmed, with minimal pipe work required, so installation
time and cost is reduced. Plus you can depend on Daikin’s
dedicated after-sales support to help ensure that commissioning
and maintenance go without a hitch.
LREQ-BY1
Multi-ZEAS Condensing Units
The Multi-ZEAS units deliver the higher capacities
required for larger supermarkets, food storage and
processing plants, while reducing energy consumption
by 35%, compared with traditional refrigeration systems.
Multi-ZEAS provides a superior solution to the traditional rack
systems typically used for bigger capacities, because the units
can be connected easily – in master and slave combination –
so installation piping is reduced and installation time is much
quicker. The new high capacity Multi-ZEAS consists of two 15hp
units or two 20hp units. This system offers the perfect solution for
multiple refrigeration needs in supermarkets and for applications
with fluctuating loads and high energy efficiency requirements,
such as blast coolers and freezers, cold storage, food outlets
and restaurants.
MT or LT refrigeration condensing unit
REFRIGERATION
System
Refrigeration
capacity
Medium temperature
Nom.
Low temperature
Nom.
Dimensions
Unit
Height x Width x Depth
Weight
Unit
Heat exchanger
Type
Compressor
Type
Piston displacement
Speed
Output
Starting method
Fan
Type
Quantity
Air flow rate
Cooling Nom.
Fan motor
Output
Drive
Sound pressure level
Nom. at 10m free field
Operation range
Evaporator
Cooling Min.~Max.
Ambient temperature
Min.~Max.
Refrigerant
Type
Charge
Control
Refrigerant oil
Type
Charged volume
Piping
Liquid
50m or less
connections
50~130m
Gas
50m or less
50~130m
Power supply
Phase/Frequency/Voltage
Current
Nominal running current (RLA) - 50Hz
Current - 50Hz
Starting current (MSC)
Trade Price
164
Residential, Commercial and Industrial
kW
kW
mm
kg
ZEAS condensing units are far quieter than traditional units,
because inverter control keeps fan speeds low while still meeting
cooling demand. At night maximum fan speeds can be lowered
to reduce noise, with only a limited loss of refrigeration capacity.
The ‘plug and play’ units come fully equipped and do not need to
be installed in a plant room, so retail space is maximised. All ZEAS
units have optimised controls, which can communicate with a
third party monitoring system or building management system via
Daikin’s powerful Modbus interface. Servicing and maintenance is
also simple.
LREQ30BY1
LREQ40BY1
LREQ15BY1R x 2
67.8
27.8
(1,680 x 1,240 x 765) x 2
331 x 2
LREQ20BY1R x 2
75.8
29.6
(1,680 x 1,240 x 765) x 2
337 x 2
Cross fin coil
Hermetically sealed scroll compressor
m³/h
rpm
W
32.24 x 2
(5,280+2,900+2,900) x 2
(2.6+3.6+3.6) x 2
35.80 x 2
(6,960+2,900+2,900) x 2
Direct online (inverter driven)
Propeller fan
m³/sec
W
2x2
3.833 x 2
(350 x 2) x 2
2x2
4.000 x 2
(750 x 2) x 2
Direct drive
dBA
°CDB
°C
45.0
46.0
-45~10
-20~43
R-410A
11.5 x 2
Electronic expansion valve
Daphne FVC68D
(1.7+ 2.1+2.1+ 4.0) x 2
kg
l
3/4 (19.05)
1 5/8 (41.28)
Hz/V
A
A
3~/50/380~415
(7.0/8.2/8.2) x 2
(9.5/8.4/8.4) x 2
109
115
£32,814.00
£37,284.00
Accessories for ZEAS and Conveni-Pack
BHGP26A1
Digital pressure gauge kit
The digital measurement display allows you to diagnose a
unit at a glance and it can be used with all ZEAS units and
Conveni-Pack systems.
> D
igital measurement display for fixed installation or
service applications
> Displays high and low pressure
> Displays error codes in the event of a fault
> Displays up to 32 operating parameters
> Displays error code history (last three)
> Scrolls and stores output values
> Automatically returns to normal operating display mode
Discharge pressure display
Suction pressure
display
BHGP26A1
Part No
Description
Trade Price
BHGP26A1
Digital pressure gauge
£320.00
MPa display
BRR9A1V1
Modbus communication kit
The interface allows you to read all the operational parameters and
control important values using the Modbus protocol. This unifying
component transforms ZEAS and Conveni-Pack into a transparent,
customisable refrigeration unit and means that you can create
object-specific and energy-optimised shop concepts, including
remote monitoring application.
Pro-interfaces can be used to connect up to 32 ZEAS units, and are
also suitable for use with Conveni-Pack systems and the Booster.
Control values
>
>
>
>
REFRIGERATION
The Daikin Modbus Communication Interface lets you fully integrate
Daikin ZEAS and Daikin Conveni-Pack systems with building control
automation networks and other monitoring systems.
T arget evaporation temperature
Low pressure level for on and off points
Forced stop
Error messages can be cancelled remotely
Display values
>
>
>
>
>
>
odel information and operating status
M
Refrigerant operating pressure and temperatures
Electrical operating data and temperatures for components
Target values
Fan stage and compressor frequency, operating hours
Warning and error messages as well as system safety functions
Part No
Description
Trade Price
BRR9A1V1
Modbus communication unit
£824.00
BRR9A1V1
Price List 2016
165
HSH/M/L 31 - HA
Industrial Condensing Units with Screw Compressor
Condensing unit for industrial refrigeration
REFRIGERATION
> H
igh energy efficiency: inverter controlled compressor,
economiser, high performance condenser
> Possibility of having a stand-by compressor
> Easy installation, ready to connect evaporators
> Integrated starter and control panel with electronic controller
> Space saving construction due to the compact design of the
condenser coils arranged in a ‘W’ configuration
> Low sound operation
> Approved according to EN 378: 2008
(Safety and environmental requirements)
> Refrigerants: R-404A, R-134a, R-407C, R-507A
Optional
>
>
>
>
ariable speed inverter technology
V
Variable condenser fan speed
Economiser (sub cooler)
Optional standby compressor on single
compressor systems
> Low sound level unit with sound pressure
level 64 dBA at 10 metres. Sound reduction
kits can be supplied with lower sound level
up to 52 dBA at maximum capacity
Width
Height
mm
mm
mm
Weight
kg
From
2,240
2,235
2,340
2,405
To
4,940
2,235
2,340
4,496
Performance overview
LT Economised 2 compressors
LT Economised 1 compressor
LT Standard 2 compressors
Applications
>
>
>
>
>
>
Length
LT Standard 1 compressor
old stores
C
Blast chillers
Blast freezers
Food processing
Food distribution centres
Large supermarkets
MT Economised 2 compressors
MT Economised 1 compressor
MT Standard 2 compressors
MT Standard 1 compressor
0
50
100
150
200
250
300
350
400
450
Capacity at +32°C in kW
Part No
Description
Trade Price
HSH/M/L 31 - HA
Industrial condensing unit
POA
166
Residential, Commercial and Industrial
LT Evaporating T = -35°C
MT Evaporating T = -10°C
Daikin UK Price List 2016
Applied
Daikin Chillers and Condensing Units
168
Daikin Fan Coil Units
176
Daikin Modular Air Handling Units
186
APPLIED
Save energy with Daikin ‘Total Inverter Solutions’
Scottish
Region
0845 641 9330
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
Daikin Chillers
Whatever your needs in climate control or process chilling,
there is a system that has proved its value in many situations –
from factories and warehouses to hotels and department stores,
APPLIED
and even district cooling for residential applications.
Daikin’s ranges of air-cooled and water-cooled chillers are designed
to suit every application – large or small – offering the ultimate
in flexibility and control. The unique combination of advanced
technology, experience and reliability make Daikin chillers the
ideal choice.
Highest efficiency
Daikin chillers have nominal cooling capacities of 5kW to 2,000kW
(air-cooled) or 13kW to 2,156kW (water-cooled).
> Lowest total cost of ownership
Worldwide experience
A global leader in HVAC solutions, Daikin has the world’s most
advanced facilities for air conditioning research and development,
meaning that we can manufacture all main chiller components
(compressors, fans, condenser coils, software) in-house.
Using the latest technology, Daikin achieves industry-leading
efficiency and energy-saving operation for outstanding cost
saving performance.
> Fast payback time
> Environment-friendly solutions
Quality, reliability
> Zero defect policy ensures quality of components and
finished products
> All chillers factory run and subjected to quality audit
before shipment
> Eurovent and AHRI certification
168
Residential, Commercial and Industrial
High Efficiency Inverter Chiller Ranges
High efficiency inverter chiller ranges for
comfort and process cooling / heating.
Why break from tradition?
> Seasonal efficiency
> Seasonal quietness
> Low starting currents
> Flexibility for new build or replacement projects
High efficiencies both at full load and part load
> Factory leak-tested and pre-charged
> High serviceability
> User-friendly smart controls which can be integrated
easily with building management systems
> D
aikin compressor with in-built inverter and Variable Volume
Ratio (VVR) for optimised efficiency
> In-house developed software with dynamic condensing pressure
management and innovative economiser control logic
Rapid return on investment
Benefits for the consultant
> P
ayback of three years, compared to a non-inverter unit for
comfort cooling applications
> Less than one year a for process cooling applications
> Multiple options available, e.g. rapid restart, variable
speed water pumps, smart energy meter, EC fans
> Ideal for both new and retrofit projects: same
footprints of non-inverter unit with higher
efficiencies and performance
Perfect comfort level
Benefits for the end user
> Rapid payback of three years for comfort
cooling applications
> 50% reduction of energy consumption
> Designed for sound-sensitive environments
APPLIED
Benefits for the installer
> Infinitely variable load regulation
> Precise leaving water temperature control thanks to
stepless regulation
Compact design
> M
ore compact heat exchanger with superior efficiencies
> Reduced electrical panel dimensions thanks to the inverter
compressor mounted.
Price List 2016
169
Products Overview
Air Cooled Chillers and Condensing Units
Sound version

BPHE
R-410A
1

BPHE
EWAQ~E-
R-410A
1
EWAQ~F-
R-410A
2
EWAQ~GZ
R-410A
1-2
EWAD~E-
R-134a
1
 
EWAD~D-
R-134a
2
    
EWAD~C-
R-134a
2-3
EWAD~CZ
R-134a
2-3
EWAD~CF
R-134a
2
EWAD~TZ
R-134a
1-2

EWYQ~ADVP
R-410A
1

EWYQ~ACV3/ACW1
R-410A
1


EWYQ~BA*
R-410A
1


SEHVX-AAW
SERHQ-AAW1
R-410A
1


BPHE
R-410A
1

BPHE



EWYQ~F-
R-410A
1-2



  
EWYD~BZ
R-134a
2-3
R-134a
1
Reduced

Low
1
Standard
R-410A
High ambient
EWAQ~BA*
Premium

High

Standard
1
Single pass shell
and tube
R-410A
Plate **
EWAQ~ACV3/ACW1
Screw

Scroll
1
Swing
R-410A
Free cooling
EWAQ~ADVP
Inverter
Refrigerant circuits
Efficiency version
Extra low
Water heat
exchanger
Refrigerant type *
Compressor
Cooling only
NEW


BPHE







 




  


 
  




BPHE
POA
EWAQ~G-








 
    

   
  



  



  
    


APPLIED
Heat pump
POA
EWYQ~G-
NEW


BPHE



BPHE



BPHE







 
 


 
Condensing unit
ERAD~E* (GWP) : R-410A (2087.5), R-134a (1430)
** BPHE: Brazed plate heat exchanger
*** Mandatory commissioning by Daikin Airconditioning UK
170
Residential, Commercial and Industrial

Mini chillers
Air cooled screw chillers
Ideal for residential or light commercial applications, Daikin mini
chillers are equipped with an inverter swing or scroll compressor
allowing a smooth, more reliable and energy-efficient operation
with low noise levels and class-leading ESEERs.
Manufactured for large capacities, Daikin screw chillers deliver
unparalleled reliability and efficiency, both for comfort and process
cooling. Equipped with an inverter they provide high efficiency at
part load.
Air cooled scroll chillers
Daikin scroll chillers are designed for small and medium cooling
and heating capacities. Our wide range of models matches every
building’s air conditioning and process cooling needs.
Cooling capacity (kW)
Heating capacity (kW)
0
17.5
200
500
1,000
2,000
5.3~7.2
8.6~17.0
16.6~64.5
69.3~154
172~334
*** Mandatory commissioning
165~672
196~395
98~411
177~620
617~2,002
696~1,795
602~1,555
170~710
0
17.5
200
500
1,000
2,000
500
1,000
2,000
5.3~7.2
5.6~8.2
8.6~17.0
9.9~14.8
16.6~64.5
20.7~74.3
75.2~165
82.2~170
158~624
173~674
247~580
271~618
0
17.5
200
116~488
*** Mandatory commissioning
21.3~63.7
Please contact your local sales office for further information on these products and extensive option flexibility – download info from daikin.co.uk
Price List 2016
171
APPLIED
16.2~63.7
Products Overview
Water Cooled and Condenserless Chillers
Sound
version
Standard
High
Efficiency version
Standard
Single
pass shell
and tube
Centrifugal
Screw
Scroll
Inverter
Refrigerant circuits
Refrigerant type *
Plate **
Water heat
exchanger
Compressor
Water cooled chillers (Cooling only & Heating only)
POA
EWWP~KBW1N
R-407C
1-2-4-6



EWHQ~G-
NEW
R-410A
1


EWWQ~G-
NEW
R-410A
1




EWWQ~L-
NEW
R-410A
2




EWWD~J-
R-134a
1-2




EWWD~G-
R-134a
1-2





EWWD~I-
R-134a
1-2-3




EWWD~H-
R-134a
1



Flooded


R-410A
1-2





EWLP~KBW1N
R-407C
1-2

BPHE



EWLQ~G-
R-410A
1




EWLQ~L-
R-410A
2




EWLD~J-
R-134a
1-2




EWLD~G-
R-134a
1-2




EWLD~I-
R-134a
1-2-3




R-134a
1
POA
Water cooled chillers (Cooling only)
EWWQ~B-
Water cooled centrifugal chillers
POA
APPLIED
POA
Condenserless chillers
EWWD~FZ
* (GWP) : R-410A (2087.5), R-134a (1430), R-407C (1,773.9)
** BPHE: Brazed plate heat exchanger
*** Mandatory commissioning by Daikin Airconditioning UK
172
Residential, Commercial and Industrial



Flooded


Water cooled scroll chillers
Water cooled, oil free centrifugal chillers
These units are among the most efficient, quiet and reliable chillers
available today which can be easily integrated with the HVAC
system of your choice.
With a small footprint, quiet compressor and ability to integrate
easily with existing HVAC systems, this chiller is the ideal solution
for large cooling requirements (e.g. district cooling) and offers a
return on investment throughout its lifecycle.
Water cooled screw chillers
The Daikin water cooled screw chillers provide the ideal solution
for sound sensitive environments. Applications range from comfort
cooling to ice making.
Cooling capacity (kW)
Heating capacity (kW)
0
17.5
200
500
1,000
2,000
1,000
2,000
1,000
2,000
1,000
2,000
12.9~194
16.7~249
87.3~352
107~420
93.7~370
107~426
*** Mandatory commissioning
187~721
213~837
120~568
142~681
165~602
209~743
332~1,503
424~1,951
368~1,212
454~1,488
0
17.5
200
500
379~2,156
0
17.5
200
500
12.1~62.4
110~529
160~524
315~1,433
0
17.5
200
500
APPLIED
173~676
*** Mandatory commissioning
86.5~346
113~1,054
Please contact your local sales office for further information on these products and extensive option flexibility – download info from daikin.co.uk
Price List 2016
173
Air Cooled Water Chillers
Air Cooled Inverter Packaged Swing / Scroll Compressor –
R410A c/w Hydraulic Pump and Expansion Vessel
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
EWAQ005ADVP
EWAQ006ADVP
EWAQ007ADVP
EWAQ009ACV3P
EWAQ010ACV3P
EWAQ011ACV3P
EWAQ009ACW1P
EWAQ011ACW1P
EWAQ013ACW1P
5.20
6.00
7.10
8.60
9.60
11.10
9.10
11.10
13.30
-
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
3-phase
3-phase
3-phase
Trade Price
EWAQ~P
Base Unit
EWAQ~P-HBase Unit with
OP10
£2,071.00
£2,244.00
£2,465.00
£2,925.00
£3,074.00
£3,275.00
£3,033.00
£3,300.00
£3,473.00
£1,840.00
£2,016.00
£2,234.00
£2,550.00
£2,699.00
£2,900.00
£2,660.00
£2,925.00
£3,098.00
Air Cooled Inverter Packaged Scroll Compressor – R410A
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
EWAQ016BAW
EWAQ021BAW
EWAQ025BAW
EWAQ032BAW
EWAQ040BAW
EWAQ050BAW
EWAQ064BAW
17.4
21.7
25.8
32.3
43.4
51.8
64.5
-
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
Trade Price
EWAQ-BAWN
Base Unit
EWAQ-BAWNBHBase Unit with
OP10+OPZL
£4,959.00
£5,728.00
£6,381.00
£7,266.00
£9,591.00
£10,594.00
£12,110.00
£4,342.00
£5,111.00
£5,764.00
£6,649.00
£8,794.00
£9,797.00
£11,313.00
EWAQ-BAWPBHStd Pump Unit with
OP10+OPZL
£5,351.00
£6,120.00
£6,773.00
£7,789.00
£10,114.00
£11,117.00
£12,633.00
EWAQ-BAWHBHHigh Pump Unit with
OP10+OPZL
£5,534.00
£6,303.00
£6,956.00
£7,841.00
£10,373.00
£11,376.00
£12,892.00
Air Cooled Heat Pump Water Chillers
Air Cooled Heat Pump Inverter Packaged Swing / Scroll Compressor –
R410A c/w Hydraulic Pump and Expansion Vessel
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
EWYQ005ADVP
EWYQ006ADVP
EWYQ007ADVP
EWYQ009ACV3P
EWYQ010ACV3P
EWYQ011ACV3P
EWYQ009ACW1P
EWYQ011ACW1P
EWYQ013ACW1P
5.20
6.00
7.10
8.60
9.60
11.10
9.10
11.10
13.30
5.65
6.35
7.75
9.90
11.40
12.90
10.90
12.40
13.90
1-phase
1-phase
1-phase
1-phase
1-phase
1-phase
3-phase
3-phase
3-phase
Trade Price
EWYQ~P
Base Unit
EWYQ~P-HBase Unit with
OP10
£2,355.00
£2,523.00
£2,768.00
£3,309.00
£3,464.00
£3,650.00
£3,424.00
£3,684.00
£3,873.00
£2,124.00
£2,295.00
£2,540.00
£2,934.00
£3,089.00
£3,275.00
£3,049.00
£3,309.00
£3,498.00
APPLIED
Air Cooled Heat Pump Inverter Packaged Scroll Compressor – R410A
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
EWYQ016BAW
EWYQ021BAW
EWYQ025BAW
EWYQ032BAW
EWYQ040BAW
EWYQ050BAW
EWYQ064BAW
17.4
21.7
25.8
32.3
43.4
51.8
64.5
16.2
20.3
24.6
30.7
40.6
49.0
61.5
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
Trade Price
EWYQ-BAWN
Base Unit
EWYQ-BAWNBHBase Unit with
OP10+OPZL
£5,609.00
£6,494.00
£7,246.00
£8,262.00
£10,907.00
£12,061.00
£13,806.00
£4,992.00
£5,877.00
£6,629.00
£7,645.00
£10,110.00
£11,264.00
£13,009.00
Notes:
Fitted Options:
i)Please contact your local sales office for further information on
these products – Download information from www.daikin.co.uk
To Fit Model EWAQ-A & EWYQ-A
Option
Description
OP10
Evaporator Heater Tape
ii)Nominal cooling capacities are based on 35°C ambient,
chilled water @ 12/7°C
iii)Nominal heating capacities are based on 7°C db / 6°C wb ambient,
water @ 40 / 45°C
iv)EWA/YQ series only operates in cooling down to ambients of +10°C
v)The EWA/YQ064BA delivery does not include offloading to kerbside.
Additional costs for delivery with a Hi-ab are available on request
vi)Commissioning by Daikin Airconditioning UK is not mandatory,
however can be arranged through your regional service department
174
Residential, Commercial and Industrial
EWYQ-BAWPBHStd Pump Unit with
OP10+OPZL
£6,001.00
£6,886.00
£7,638.00
£8,785.00
£11,430.00
£12,584.00
£14,329.00
EWYQ-BAWHBHHigh Pump Unit with
OP10+OPZL
£6,184.00
£7,069.00
£7,821.00
£8,837.00
£11,689.00
£12,843.00
£14,588.00
EWA/YQ-ADVP
005
006
007
£231 £231 £231
EWA/YQ-ACV3P
009
010
011
£375 £375 £375
EWA/YQ-ACW1P
009
011
013
£375 £375 £375
016
£353
£264
£392
£575
032
£353
£264
£523
£575
064
£444
£353
£523
£782
To Fit Model EWAQ-BA & EWYQ-BA
Option
Description
OP10-D
OPZL
OPSP
OPHP
Evaporator Heater Tape
Chilled Water Down to -10
Low Lift Pump
High Lift Pump
021
£353
£264
£392
£575
025
£353
£264
£392
£575
040
£444
£353
£523
£782
050
£444
£353
£523
£782
Water Cooled Chillers
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
To Fit Model EWWP-KAW1N
Water Cooled Packaged Scroll Compressor – R407C
EWWP014KBW1N
EWWP022KBW1N
EWWP028KBW1N
EWWP035KBW1N
EWWP045KBW1N
EWWP055KBW1N
EWWP065KBW1N
12.90
21.40
27.80
32.30
42.80
55.70
64.70
-
Fitted Options:
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£2,410.00
£3,066.00
£3,530.00
£3,952.00
£4,934.00
£5,850.00
£6,486.00
Option
Description
014
022
028
035
045
055
065
OPZH
OPZL
Chilled Water Down to -5
Chilled Water Down to -10
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
Notes:
i)Please contact your local sales office for further information on
these products – Download information from www.daikin.co.uk
ii)Nominal cooling capacities are based on chilled water @ 12/7°C,
condenser water @ 30/35°C
iii)Commissioning by Daikin Airconditioning UK is not mandatory,
however can be arranged through your regional service department
Condenserless Chillers
Model
No
Nominal
Cooling
kW
Nominal
Heating
kW
Power
Supply
Trade
Price
To Fit Model EWLP-KAW1N
Condenserless Packaged Scroll Compressor – R407C
EWLP012KBW1N
EWLP020KBW1N
EWLP026KBW1N
EWLP030KBW1N
EWLP040KBW1N
EWLP055KBW1N
EWLP065KBW1N
12.10
20.00
26.80
31.20
40.00
53.70
62.40
-
Fitted Options:
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
3-phase
£2,049.00
£2,607.00
£3,000.00
£3,359.00
£4,194.00
£4,973.00
£5,513.00
Option
Description
012
020
026
030
040
055
065
OPZH
OPZL
Chilled Water Down to -5
Chilled Water Down to -10
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
£122
Notes:
i)Please contact your local sales office for further information on
these products – Download information from www.daikin.co.uk
ii)Nominal cooling capacities are based on chilled water @ 12/7°C,
condensing temperature @ 45°C, liquid temperature @40°C
iii)Commissioning by Daikin Airconditioning UK is not mandatory,
however can be arranged through your regional service department
Applied Systems Kit Options
Model
Description
Trade Price
DTA104A62
EHMC10A10
EHMC10A80
EHMC15A10
EHMC15A80
EHMC30A10
EHMC30A80
EKAC10C
EKRUMCA
EKBT
EKLS1
EKLS2
EKLS2 X 2
EKRP1HBA
EKRP1AHT
EKRUAHTB
RTD-W
EKCC-W
External control adaptor Low noise & demand limit - EWAQ/EWYQ-BA
HYDRAULIC MODULE -Normal static + anti-freeze protection - EWWP014~022/EWLP012~020
HYDRAULIC MODULE-High static + anti-freeze protection - EWWP014~022/EWLP012~020
HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP028~035/EWLP026~030
HYDRAULIC MODULE-High static + anti-freeze protection - EWWP028~035/EWLP026~030
HYDRAULIC MODULE-Normal static + anti-freeze protection - EWWP045~065/EWLP040~065
HYDRAULIC MODULE-High static + anti-freeze protection - EWWP045~065/EWLP040~065
Address card for connection to BMS - EWWP, EWLP (note not available on the modular EWWP)
Remote Control - EWWP, EWLP (needs EKAC10C)
Buffertank 200I
Low noise operation EWLP012~EWWP14
Low noise operation EWLP02~030, EWWP22-35
Low noise operation EWLP040~065, EWWP45-65
Digital I/O PCB - EWAQ / EWYQ - AC
Demand PCB / Inputs - EWAQ/EWYQ-BA (2 x on size 40/50/64)
Remote user interface (in parallel) - EWAQ/EWYQ-BA
MODBUS Interface - EWAQ/EWYQ-BA
Sequence Controller - EWAQ/EWYQ-BA
£221.00
£1,668.00
£1,775.00
£1,775.00
£1,848.00
£1,991.00
£1,991.00
£86.00
£163.00
£1,097.00
£155.00
£155.00
£310.00
£104.00
£104.00
£157.00
£205.00
£640.00
APPLIED
Loose Accessory Options:
Daikin Commissioning & Maintenance
Model
Description
Net Price
UK.FSCC/SMALL
UK.FSCC/MEDIUM
UK.FSCC/LARGE
UK.FSCM/SMALL
UK.FSCM/MED
UK.FSCM/LARGE
Commissioning for small size chiller <70kW (price per chiller)
Commissioning for medium size chiller 70-999kW (price per chiller)
Commissioning for chiller large >1000kW ~ (price per chiller)
Maintenance contract for small size chiller <70kW (price per maintenance visit)
Maintenance contract for medium size chiller 70-999kW (price per maintenance visit)
Maintenance contract for large size chiller >1000kW ~ (price per maintenance visit)
£685.00
£877.50
£1,170.00
£342.50
£685.00
£1,027.50
Notes:
i)Commissioning is mandatory on all chillers with a
nominal capacity >70kW and as indicated on the
product overview pages 170-173
Please contact your regional service department for further information on these services.
Price List 2016
175
Product Overview
Fan Coil Units
Fan Coil Units are a highly efficient means
of turning a water chiller, heat pump or
hot water boiler into an efficient, quiet air
conditioning system. These units are an
effective solution to provide a comfortable
environment for both commercial and
residential applications. Daikin offers a wide
range of Fan Coil Units for both concealed
and exposed applications, to suit particular
APPLIED
installation requirements. Many of these
are available with Brushless Direct Current
(BLDC) Fan Motors providing high energy
efficiency and comfort levels.
176
Residential, Commercial and Industrial
High Efficiency BLDC Fan Coil Units
High efficiency BLDC Fan Coil units for
comfort cooling / heating.
Brushless DC Motors for:
> Higher operational efficiency
> Tighter comfort control
> Low sound levels
Higher efficiency than AC (Alternative Current) motor
Benefits for the installer
> Reduced amount of sizes: less stock space needed
> Modular designs for multiple configurations
> E asy integration in BMS system via modbus protocol*
* except for FWG-AT/AF range
Benefits for the consultant
> Best solution in the market in order to have top
efficiency,best comfort and lowest sound levels
>
>
>
>
p to 70% energy savings
U
No heat generation
No power losses
Higher efficiency than AC motors to reach set point
High comfort level
>
>
>
>
L ess fluctuation of air temperature and relative humidity
More consistent output level
Stepless speed change for gradual air output
More accurate adjustments to reach set point
Benefits for the end user
APPLIED
Low sound levels
> L ower minimum rotation speed
> No start-stop sequence
> Gradual air output
> High comfort level
> Up to 70% savings on running costs
> Controller with timer programmed operating mode
Price List 2016
177
Product Overview
Fan Coil Units
Type
Model
Ceiling mounted cassette
Floor standing unit
Flexi type unit
Product name
Fan motor type
Roundflow cassette
- Brushless DC fan motor unit for ceiling mounting
- 360° air discharge ensures uniform air flow
- Integrated fresh air intake
- Easy installation in corners
- Standard drain pump with 850 mm lift
FWC-BT/BF
BLDC
4-way blow ceiling mounted cassette
- AC fan motor unit for ceiling mounting
- Integrated fresh air intake
- Horizontal auto swing
- Easy installation in corners
- Standard drain pump with 750 mm lift
FWF-BT/BF
AC
Floor standing unit
- Brushless DC fan motor for vertical mounting
- Continuous air flow regulation and fan speed modulation
- Up to 70% energy savings
- Low sound levels
FWZ-AT/AF
BLDC
Floor standing unit
- AC fan motor unit for horizontal or vertical concealed mounting
- Insulated valve packages, no extra drain pan required
- Fast-on connections for electrical options: no tools needed
- Easy maintenance
FWV-DAT/DAF
AC
Flexi type unit
- Brushless DC fan motor unit for horizontal or vertical mounting
- Continuous air flow regulation and fan speed modulation
- Up to 70% energy savings
- Low sound levels
FWR-AT/AF
BLDC
Flexi type unit
- AC fan motor unit for horizontal or vertical concealed mounting
- Insulated valve packages, no extra drain pan required
- Fast-on connections for electrical options: no tools needed
- Easy maintenance
FWL-DAT/DAF
AC
FWS-AT/AF
BLDC
FWM-DAT/DAF
AC
Wall mounted unit
- AC fan motor unit for wall mounting
- High aesthetic cabinet design
- Optimum air distribution
- Easy installation
- 3-speed fan motor
FWT-CT
AC
Concealed ceiling unit with medium ESP
- Brushless DC fan motor unit for horizontal concealed mounting
- Instant adjustment to temperature and relative humidity changes
- Available static pressure up to 80 Pa
- Low sound levels
FWP-AT
BLDC
Concealed ceiling unit with medium ESP
- AC fan motor unit for horizontal concealed mounting
- Available static pressure up to 80 Pa
- 7-speed electrical motors (thermal protection on windings)
- Easy maintenance
FWB-BT
AC
FWD-AT/AF
AC
Concealed flexi type unit
- Brushless DC fan motor unit for horizontal or vertical concealed mounting
- Continuous air flow regulation and fan speed modulation
- Up to 70% energy savings
- Low sound levels
Concealed flexi type unit
- AC fan motor unit for horizontal or vertical concealed mounting
- Insulated valve packages, no extra drain pan required
- Fast-on connections for electrical options: no tools needed
- Easy maintenance
Wall mounted unit
Concealed ceiling unit
APPLIED
Concealed ceiling unit with high ESP
- AC fan motor unit for horizontal or vertical concealed mounting
- Available static pressure up to 120 Pa
- Easy maintenance
Capacity conditions
EUROVENT conditions
Cooling
27°C db / 19°C wb - Entering water 7°C - Leaving water 12°C
Heating 4 Pipe
20°C db - Entering water 70°C - Leaving water 60°C
Heating 2 Pipe
20°C db - Entering water 50°C - Flow rate as in cooling mode
178
Residential, Commercial and Industrial
Capacity class (kW)
1
2
3
4
5
Cooling: 2.0 - 5.2 kW
Heating: 2.9 - 6.7 kW
6
7
8
9




Cooling: 2.49 - 4.54 kW
Heating: 3.52 - 5.28 kW


Cooling: 2.64 - 10.08 kW
Heating: 2.46 - 11.18 kW













Cooling: 2.43 - 5.28 kW
Heating: 3.22 - 7.33 kW





Cooling: 2.61 - 6.47 kW
Heating: 5.47 - 12.28 kW






Cooling: 2.61 - 10.34 kW
Heating: 5.47 - 18.78 kW






Cooling: 1.46 - 8.02 kW
Heating: 1.90 - 10.03 kW

Cooling: 2.64 - 10.08 kW
Heating: 2.46 - 11.18 kW
Cooling: 1.46 - 8.02 kW
Heating: 1.90 - 10.03 kW

Cooling: 2.64 - 10.08 kW
Heating: 2.46 - 11.18 kW
Cooling: 1.46 - 8.02 kW
Heating: 1.90 - 10.03 kW

Cooling: 3.90 - 18.30 kW
Heating: 4.05 - 21.92 kW

11
12 ~
18









10


















Please contact your local sales office for further information on these products and extensive option flexibility – download info from daikin.co.uk
TYPICAL UK cooling conditions
22°C db / 16.0°C wb - Entering water 7°C - Leaving water 12°C
0 Pa External Static Pressure
0% Glycol
FWP & FWD Ducted FCU - Above capacities are based on 30 Pa
External Static Pressure
FWS Uncased - Based on 20 pa external static
Price List 2016
179
APPLIED
Capacity
New BLDC (Brushless Direct Current)
Inverter Driven Floor Standing Fan Coil Units
Cased Low Wall Mount Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height x Width x Depth
High/Low
High/Low
High
kW
kW
kW
mm
kg
dBA
dBA
m3/min
inch
FWZ06AT
FWZ08AT
2.57
4.96
6.4
226 x 987 x 564
25
70/28
62/20
15
1/2
3.23
6.32
7.51
226 x 1194 x 564
31
64/28
56/20
20
1/2
5.11
10.08
11.18
251 x 1404 x 564
41
71/28
63/20
27.66
3/4
FWZ02ATN
£254.00
FWZ02ATT6V3ES£509.00
FWZ02ATV6V3ES£577.00
FWZ03ATN
£269.00
FWZ03ATT6V3ES£531.00
FWZ03ATV6V3ES£598.00
FWZ06ATN
£311.00
FWZ06ATT6V3ES£581.00
FWZ06ATV6V3ES£653.00
FWZ08ATN
£389.00
FWZ08ATT6V3ES£664.00
FWZ08ATV6V3ES£743.00
FWZ02AF
FWZ03AF
FWZ06AF
FWZ08AF
1.39
2.64
2.46
226 x 774 x 564
21
62/28
54/20
9.33
1/2
2.57
4.96
4.19
226 x 987 x 564
26
70/28
62/20
15
1/2
3.23
6.32
6.45
226 x 1194 x 564
33
64/28
56/20
20
1/2
5.11
10.08
10.06
251 x 1404 x 564
44
71/28
63/20
27.66
3/4
FWZ06AFN
£349.00
FWZ06AFT6V3-S£496.00
FWZ06AFV6V3-S£609.00
FWZ08AFN
£428.00
FWZ08AFT6V3-S£578.00
FWZ08AFV6V3-S£698.00
1ph
Trade Fan Coil Price - Complete with 2-way 230V valve,
Elec Heater & FWECSAP power control factory fitted
Trade Fan Coil Price - Complete with 3-way 230V valve,
Elec Heater & FWECSAP power control factory fitted
Cased Low Wall Mount Type 4-pipe
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWZ03AT
1.39
2.64
3.47
226 x 774 x 564
20
62/28
54/20
9.33
1/2
Power Supply
Trade Fan Coil Price - Naked - No Valve
Capacity
FWZ02AT
UK Total Cooling
Nominal Cooling
Nominal Heating
Height x Width x Depth
High/Low
High/Low
High
kW
kW
kW
mm
kg
dBA
dBA
m3/min
inch
Power Supply
1ph
Trade Fan Coil Price - Naked - No Valve
Trade Fan Coil Price - Complete with 2-way 230V valve
and FWECSAP power control factory fitted
Trade Fan Coil Price - Complete with 3-way 230V valve
and FWECSAP power control factory fitted
FWZ02AFN
£277.00
FWZ02AFT6V3-S£424.00
FWZ02AFV6V3-S£537.00
FWZ03AFN
£294.00
FWZ03AFT6V3-S£441.00
FWZ03AFV6V3-S£554.00
Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network
New BLDC (Brushless Direct Current)
Inverter Driven Flexi Fan Coil Units
Cased Flexi Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height x Width x Depth
High/Low
High/Low
High
kW
kW
kW
mm
kg
dBA
dBA
m3/min
inch
APPLIED
FWR06AT
FWR08AT
2.57
4.96
6.4
226 x 987 x 564
27
70/28
62/20
15
1/2
3.23
6.32
7.51
226 x 1194 x 564
33
64/28
56/20
20
1/2
5.11
10.08
11.18
251 x 1404 x 564
44
71/28
63/20
27.66
3/4
FWR02ATN
£266.00
FWR02ATT6V3ES£521.00
FWR02ATV6V3ES£589.00
FWR03ATN
£288.00
FWR03ATT6V3ES£550.00
FWR03ATV6V3ES£617.00
FWR06ATN
£332.00
FWR06ATT6V3ES£602.00
FWR06ATV6V3ES£674.00
FWR08ATN
£424.00
FWR08ATT6V3ES£699.00
FWR08ATV6V3ES£778.00
FWR02AF
FWR03AF
FWR06AF
FWR08AF
1.39
2.64
2.46
226 x 774 x 564
22
62/28
54/20
9.33
1/2
2.57
4.96
4.19
226 x 987 x 564
28
70/28
62/20
15
1/2
3.23
6.32
6.45
226 x 1194 x 564
35
64/28
56/20
20
1/2
5.11
10.08
10.06
251 x 1404 x 564
46
71/28
63/20
27.66
3/4
FWR06AFN
£368.00
FWR06AFT6V3-S£515.00
FWR06AFV6V3-S£628.00
FWR08AFN
£468.00
FWR08AFT6V3-S£618.00
FWR08AFV6V3-S£738.00
1ph
Trade Fan Coil Price - complete with 2-way 230V valve,
Elec Heater & FWECSAP power control factory fitted
Trade Fan Coil Price - Complete with 3-way 230V valve,
Elec Heater & FWECSAP power control factory fitted
Cased Flexi Type 4-pipe
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWR03AT
1.39
2.64
3.47
226 x 774 x 564
21
62/28
54/20
9.33
1/2
Power Supply
Trade Fan Coil Price - Naked - No Valve
Capacity
FWR02AT
UK Total Cooling
Nominal Cooling
Nominal Heating
Height x Width x Depth
High/Low
High/Low
High
kW
kW
kW
mm
kg
dBA
dBA
m3/min
inch
Power Supply
Trade Fan Coil Price - Naked - No Valve
Trade Fan Coil Price - Complete with 2-way 230V valve
and FWECSAP power control factory fitted
Trade Fan Coil Price - Complete with 3-way 230V valve
and FWECSAP power control factory fitted
1ph
FWR02AFN
£291.00
FWR02AFT6V3-S£438.00
FWR02AFV6V3-S£551.00
FWR03AFN
£313.00
FWR03AFT6V3-S£460.00
FWR03AFV6V3-S£573.00
Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network
180
Residential, Commercial and Industrial
New BLDC (Brushless Direct Current)
Inverter Driven Low Static Concealed Flexi Fan Coil Units
Concealed Flexi Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height x Width x Depth
High/Low
High/Low
High
kW
kW
kW
mm
kg
dBA
dBA
m3/min
inch
FWS02AT
FWS03AT
FWS06AT
FWS08AT
1.08
2.64
3.47
224 x 584 x 535
15
62/28
54/20
9.33
1/2
2.02
4.96
6.4
224 x 794 x 535
19
70/28
62/20
15
1/2
2.52
6.32
7.51
224 x 1004 x 535
23
64/28
56/20
20
1/2
3.99
10.08
11.18
249 x 1214 x 535
32
71/28
63/20
27.66
3/4
Power Supply
1ph
Trade Fan Coil Price - Naked - No Valve
Trade Fan Coil Price - complete with 2-way 230V valve,
Elec Heater & FWECSAP power control factory fitted
Trade Fan Coil Price - Complete with 3-way 230V valve,
Elec Heater & FWECSAP power control factory fitted
FWS02ATN
£228.00
FWS02ATT6V3ES£483.00
FWS02ATV6V3ES£551.00
FWS03ATN
£243.00
FWS03ATT6V3ES£505.00
FWS03ATV6V3ES£572.00
FWS06ATN
£280.00
FWS06ATT6V3ES£550.00
FWS06ATV6V3ES£622.00
FWS08ATN
£349.00
FWS08ATT6V3ES£624.00
FWS08ATV6V3ES£703.00
FWS02AF
FWS03AF
FWS06AF
FWS08AF
1.08
2.64
2.46
224 x 584 x 535
16
62/28
54/20
9.33
1/2
2.02
4.96
4.19
224 x 794 x 535
20
70/28
62/20
15
1/2
2.52
6.32
6.45
224 x 1004 x 535
25
64/28
56/20
20
1/2
3.99
10.08
10.06
249 x 1214 x 535
34
71/28
63/20
27.66
3/4
FWS06AFN
£313.00
FWS06AFT6V3-S£460.00
FWS06AFV6V3-S£573.00
FWS08AFN
£391.00
FWS08AFT6V3-S£541.00
FWS08AFV6V3-S£661.00
Concealed Flexi Type 4-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height x Width x Depth
High/Low
High/Low
High
kW
kW
kW
mm
kg
dBA
dBA
m3/min
inch
Power Supply
Trade Fan Coil Price - Naked - No Valve
Trade Fan Coil Price - Complete with 2-way 230V valve
and FWECSAP power control factory fitted
Trade Fan Coil Price - Complete with 3-way 230V valve
and FWECSAP power control factory fitted
1ph
FWS02AFN
£252.00
FWS02AFT6V3-S£399.00
FWS02AFV6V3-S£512.00
FWS03AFN
£273.00
FWS03AFT6V3-S£420.00
FWS03AFV6V3-S£533.00
Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network
Floor Standing and Flexi Fan Coil Unit Accessories
FWZ, FWR, FWS
2-pipe 3-way valve kits c/w lockshields
4-pipe 3-way valve kits c/w lockshields
Vertical drainpan
Horizontal drainpan
Advanced Plus Electronic Controller
Split Electronic Controller
Power control board + Control panel
On board installation kit
(FWZ & FWR - Low Wall Mounted Only)
Return Air Sensor
Notes:
02-03
06
E2MV03A6
£122.00
E4MV03A6
£219.00
EDPVB6
£5.00
EDPHB6
£5.00
FWEC3A
£115.00
FWECSA = FWECSAP + FWECSAC
£143.00 or £82.00 + £61.00
FWECKA
£11.00
FWTSKA
£8.00
08
E2MV10A6
£129.00
E4MV10A6
£231.00
i)Each controller version includes the
water probe
ii)The on board installation kit includes a
remote air probe (if installed the internal
fan coil robe is disabled)
iii)The FWEC3A can operate up to 247
fan coils as master slave control, plus
weekly schedule timer, proportional valve
control and 2 digital outputs (1 per fan
coil required)
iv)The FWECSA can operate up to 256
fan coils as master slave control on
RS485 network
APPLIED
Loose Accessory Options:
v)The FWECSAP and FWECSAC can be
ordered individually or as a pack
Price List 2016
181
New BLDC (Brushless Direct Current)
Inverter Driven Medium Static Ducted Fan Coil Units
Concealed Ducted Type 2-pipe
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High/Low
High/Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
FWP02AT
FWP03AT
FWP04AT
FWP05AT
FWP06AT
FWP07AT
1.34
2.61
5.47
239
1039
609
24
56/40
44/24
6.66
3/4
1.67
3.14
6.01
239
1039
609
26
56/40
44/24
6.66
3/4
2.03
3.49
6.47
239
1039
609
28
56/40
44/24
6.66
3/4
2.5
5.08
10.31
239
1389
609
33
61/39
50/27
13.33
3/4
2.77
5.45
11.39
239
1389
609
35
61/39
50/27
13.33
3/4
3.47
6.47
12.28
239
1389
609
38
61/39
50/27
13.33
3/4
Power Supply
Trade Fan Coil Price - Naked - No Valve
Trade Fan Coil Price - Complete with 3-way 230V valve
and FWECSAP power control factory fitted
1ph
FWP02ATN
FWP03ATN
FWP04ATN
FWP05ATN
FWP06ATN
FWP07ATN
£327.00
FWP02ATV6V3-S-
£341.00
FWP03ATV6V3-S-
£354.00
FWP04ATV6V3-S-
£415.00
FWP05ATV6V3-S-
£420.00
FWP06ATV6V3-S-
£448.00
FWP07ATV6V3-S-
£472.00
£486.00
£499.00
£561.00
£565.00
£594.00
Please note models with factory fitted FWECSAP power control, require FWECSAC control panel(s) depending on FCU control network.
If you require a 4 pipe fan coil please purchase additional heat exchanger as shown below
Loose Accessory Options:
FWP
Additional Heat exchanger (4 Pipe)
nominal heating cap 3.2kW
Additional Heat exchanger (4 Pipe)
nominal heating cap 6.1kW
2-way valve cooling coil
3-way valve add.h/e
2-way valve add.h/e
Advanced Plus Electronic Controller
Split Electronic Controller
Power control board + Control panel
APPLIED
Return Air Sensor
182
Residential, Commercial and Industrial
Notes:
02 - 04
05 - 07
EAH04A6
£90.00
-
EAH07A6
£105.00
E2MV207A6
£53.00
E2MV307A6
£93.00
E2MV207A6
£53.00
FWEC3A
£115.00
FWECSA = FWECSAP + FWECSAC
£143.00 or £82.00 + £61.00
FWTSKA
£8.00
i)Each controller version includes the
water probe
ii)The FWEC3A can operate up to 247
fan coils as master slave control, plus
weekly schedule timer, proportional valve
control and 2 digital outputs (1 per fan
coil required)
iii)The FWECSA can operate up to 256
fan coils as master slave control on
RS485 network
iv)The FWECSAP and FWECSAC can be
ordered individually or as a pack
AC Fan Motor - 3 speed
High Static Ducted Fan Coil Units
Concealed Ducted Type 2-pipe
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Concealed Ducted Type 4-pipe
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWD06AT
FWD08AT
FWD10AT
FWD12AT
FWD16AT
FWD18AT
2.15
3.9
4.05
280
754
559
33
66/54
56/46
13.33
3/4
3.48
6.2
7.71
280
964
559
41
69/59
61/51
20.83
3/4
4.44
7.8
9.43
280
1174
559
47
72/62
64/54
26.67
3/4
4.92
8.82
10.79
280
1174
559
49
72/62
64/54
26.67
3/4
1ph
7.21
11.9
14.45
352
1174
718
65
74/60
66/52
36.67
1
8.96
16.4
19.81
352
1384
718
77
78/69
70/61
50
1
9.91
18.3
21.92
352
1384
718
80
78/69
70/61
50
1
£262.00
£346.00
£405.00
£450.00
£559.00
£717.00
£789.00
FWD04AF
FWD06AF
FWD08AF
FWD10AF
FWD12AF
FWD16AF
FWD18AF
2.15
3.9
4.05
280
754
559
35
66/54
56/46
13.33
3/4
3.48
6.2
7.71
280
964
559
43
69/59
61/51
20.83
3/4
4.44
7.8
9.43
280
1174
559
50
72/62
64/54
26.67
3/4
4.92
8.82
10.79
280
1174
559
52
72/62
64/54
26.67
3/4
1ph
7.21
11.9
14.45
352
1174
718
71
74/60
66/52
36.67
1
8.96
16.4
19.81
352
1384
718
83
78/69
70/61
50
1
9.91
18.3
21.92
352
1384
718
86
78/69
70/61
50
1
£308.00
£403.00
£470.00
£521.00
£656.00
£831.00
£911.00
Power Supply
Trade Fan Coil Price
Capacity
FWD04AT
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Power Supply
Trade Fan Coil Price
Loose Accessory Options:
FWD
2-pipe 3-way valve
4-pipe 3-way valve
Vertical Drain pan
Horizontal Drain Pan
Master slave interface
Power interface (S)
Standard Electronic Controller
Advanced Electronic Controller
Advanced Plus Electronic Controller
Split Electronic Controller
Power control board + Control panel
Return Air Sensor
Notes:
4
ED2MV04A6
£128.00
ED4MV04A6
£247.00
6
8 -10
ED2MV10A6
£128.00
ED4MV10A6
£247.00
EDDPV10A6
£11.00
EDDPH10A6
£13.00
EPIMSA6
£85.00
12
16 -18
ED2MV12A6
ED2MV18A6
£128.00
£134.00
2x ED2MV12A6 2 x ED2MV18A6
£256.00
£268.00
EDDPV18A6
£11.00
EDDPH18A6
£13.00
-
EPIB6
£85.00
FWEC1A
£59.00
FWEC2A
£83.00
FWEC3A
£115.00
FWECSA = FWECSAP + FWECSAC
£143.00 or £82.00 + £61.00
FWTSKA
£8.00
F WEC1A is designed as an individual unit
controller. Power interface EPIB6 is required
for unit size 16 and 18 can operate up to
4 fan coils by adding a EPIMSA6.
If using this controller to operate up to 4
fan coil units by adding a EPIMSA6 you will
require a EPIB6 power interface for unit
size 12,16,18.
FWEC2A can operate up to 247 fan coils as
master slave control ( 1 per fan coil required).
Power interface EPIB6 is required for each
unit size 16 and 18.
FWEC3A can operate up to 247 fan coils
as master slave control, plus weekly
schedule timer, proportional valve control
(by others) and 2 digital outputs ( 1 per fan
coil required).
T he FWECSA can operate up to 256 fan coils
as master slave control on RS485 network
Please note that:
i)Each controller version includes the
water probe.
ii)The FWECSAP and FWECSAC can be
ordered individually or as a pack
APPLIED
Capacity
Price List 2016
183
AC Fan Motor - 3 speed
600 Sq Cassette Fan Coil Units
600sq Cassette Type 2-pipe c/w Decoration Panel BYFQ60B3
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
600sq Cassette Type 4-pipe c/w Decoration Panel BYFQ60B3
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
FWF03BT
FWF04BT
FWF05BT
1.20
2
2.9
260
575
575
19
44/36
31/26
7.9
1.9
3.2
4
260
575
575
19
44/36
31/26
7.9
2.5
4.2
5.4
260
575
575
19
50/36
40/26
11.2
3.1
5.2
6.7
260
575
575
19
55/42
45/30
14.9
3/4 “ BSP Female
1 ph
Power Supply
Trade Fan Coil Price
Capacity
FWF02BT
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
£509.00
£535.00
£565.00
£603.00
FWF02BF
FWF03BF
FWF04BF
FWF05BF
1.10
2
3.9
260
575
575
19
44/36
31/26
7.9
1.6
2.7
3.8
260
575
575
20
44/36
31/26
7.2
2
3.5
4.9
260
575
575
20
50/36
40/26
10.4
2.5
4.5
6.1
260
575
575
20
55/42
45/30
13.9
3/4 “ BSP Female
1 ph
Power Supply
Trade Fan Coil Price
£541.00
£565.00
£603.00
£637.00
FWC06BT
FWC07BT
FWC08BT
FWC09BT
3.30
5.8
8
288
840
840
26
43/31
29/21
17.7
4.1
6.8
8.9
288
840
840
26
47/33
33/22
20.6
4.3
7.7
10.6
288
840
840
26
53/36
39/24
25.4
4.8
8.7
12.1
288
840
840
26
57/40
43/28
30.8
BLDC Fan Motor - 3 speed
Cassette Fan Coil Units
Cassette Type 2-pipe c/w Decoration Panel BYCQ140C
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
Trade Fan Coil Price
APPLIED
Cassette Type 4-pipe c/w Decoration Panel BYCQ140C
Capacity
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
£621.00
£637.00
£653.00
£681.00
FWC06BF
FWC07BF
FWC08BF
FWC09BF
3.30
5.8
7.5
288
840
840
29
43/31
29/21
17.1
4
6.6
8.4
288
840
840
29
47/33
33/22
19.9
4.3
7.6
9.7
288
840
840
29
53/36
39/24
24.6
4.8
8.7
11
288
840
840
29
57/40
43/28
29
£691.00
£708.00
3/4 “ BSP Female
1 ph
Power Supply
Trade Fan Coil Price
184
3/4 “ BSP Female
1 ph
Power Supply
Residential, Commercial and Industrial
£649.00
£673.00
Cassette Accessories
Loose Accessory Options:
Notes:
FWF/FWC
FWF/FWC
FWC only
FWC only
Remote wired controller
BRC315D
£66.00
DCS601C51
£1,641.00
KRP4A53
£67.00
KRP4A53/UK.FB2
£92.00
KRP2A52
£177.00
KRP2A52/UK.FB2
£202.00
EKFCMBCB
£55.00
EKMV2C09B
£58.00
EKMV3C09B
£64.00
EKRP1C11
£100.00
Wireless remote control heat pump
BRC7FA532F
£152.00
BRC7F533F
£121.00
KRCS01-4
£42.00
KRP1H98
£37.00
Intelligent touch controller
Unit/Group adapter pcb
Unit/Group adapter pcb complete with
installation box
System adaptor pcb
System adaptor pcb complete with
installation box
Optional pcb for connection to ModBus
(2 stopbit)
2-Way on / off valve kit
3-Way on / off valve kit
Valve control PCB
Wireless remote control cooling only
Remote air sensor
Installation box for an EKRP1C11 valve PCB
FWF only
FWF only
Wireless remote control heat pump
BRC7E530
£121.00
BRC7E531
£121.00
KRCS01-1
£46.00
EKRORO
£16.00
KRP1BA101
£45.00
Wireless remote control cooling only
Remote air sensor
Remote on/off control interface kit
Installation box for an EKRP1C11 valve PCB
i)FWF and FWC Cassette Fan Coil prices
include decoration panel
ii)It is not possible to use Intelligent Touch
control for combination with both VRV
and water based fan coils
FWF-Valve control requirements
2 pipe unit: 1 x valve kit + 1 x installation
box for PCB KRP1BA101 + 1 x valve control
PCB EKRP1C11
4 pipe unit: 2 x valve kit + 1 x installation
box for PCB KRP1BA101 + 1 x valve control
PCB EKRP1C11
FWC-Valve control requirements
2 pipe unit: 1 x valve kit + 1 x installation
box for PCB KRP1H98 + 1 x valve control
PCB EKRP1C11
4 pipe unit: 2 x valve kit + 1 x installation
box for PCB KRP1H98 + 1 x valve control
PCB EKRP1C11
AC Fan Motor - 3 speed
Wall Mounted Fan Coil Units
Dimensions
Weight
Sound Power
Sound Pressure
Air Flow Rate
Water Connections
Electrical Data
UK Total Cooling
Nominal Cooling
Nominal Heating
Height
Width
Depth
High / Low
High / Low
High
kW
kW
kW
mm
mm
mm
kg
dBA
dBA
m3/min
inch
FWT02CT
FWT03CT
FWT04CT
FWT05CT
FWT06CT
1.59
2.43
3.22
288
800
206
10
45/36
34/25
7.36
1/2
1.67
2.7
3.52
288
800
206
10
48/39
35/25
7.93
1/2
2.1
3.31
4.4
288
800
206
10
55/45
42/32
10.48
1/2
1ph
2.9
4.54
6.01
310
1065
224
15
55/47
42/34
14.43
1/2
3.41
5.28
7.33
310
1065
224
15
59/51
42/39
17.55
1/2
£192.00
£199.00
£228.00
£276.00
£294.00
Power Supply
Trade Fan Coil Price
Loose Accessory Options:
FWT
Standard wired remote controller
Simplified wired remote controller
Wireless controller for heat pump
Notes:
FWT
MERCA
£74.00
SRC-HPA
£39.00
WRC-HPC
£15.00
i)FWT fan coils are optimised for valveless
control in cooling. We would recommend
that a valve is fitted if being used for
heating only and for more precise control
in cooling.
ii)We would recommend the field supply of
a 240V - 4 port 3 way valve complete with
240V actuator.
Price List 2016
185
APPLIED
Cased High Wall Mount Type 2-pipe
Capacity
Daikin Air Handling Units
Daikin air handling units, with their plug-and-play design and
inherent flexibility, can be configured and combined specifically
to meet the exact requirements of any building, no matter what
it is used for, or who is to work there. Our systems are designed
to be the most environmentally friendly and the most energy
efficient on the market, thus reducing their ecological impact,
APPLIED
while, at the same time, keeping costs down through the
minimisation of energy consumption.
When combined with the small physical footprint of the system,
these features make our air handling units ideal for all markets.
186
Residential, Commercial and Industrial
ADT-F/B
Air Handling Units
Modular AHU with high efficiency heat recovery
Energy efficiency and indoor air quality
> Predefined sizes
> IE4 premium efficiency motor
EC fan
> High efficiency heat wheel (heat recovery)
> Compact design
> Advanced control features
> A
ir flow or pressure control
(Variable Air Volume – Constant Air Volume)
> Easy installation
> Nominal air flow programmed at factory
> Indoor air quality compliant with VDI 6022 hygiene guideline
> Silent operation
> O
perating limits from -25 °C, -40 °C with electric heaters,
up to +46 °C ambient temperature
Simple, quick installation
> VRV IV and ERQ coupling capability
> Indoor and outdoor versions
The Modular series’ Plug & Play design is more than just a
convenient feature for installers. It offers cost-saving benefits as
there is no need for expensive adjustments before the unit is
commissioned. Plug & Play makes everyone’s life simpler, safer and
more economical.
> Free cooling capability
> Economy and Night mode operation
> Monitoring and control through Daikin ITM
Unit Nominal Performances
(Main Module)
Size
Airflow [m3/h]
Temp efficiency winter [%]
ESP nominal [Pa]
Current nominal [A]
Power input nominal [kW]
SFPv [kW/m3/s]
Electrical supply [V-ph-Hz]
Lenght [mm]
Depth [mm]
Height overall [mm]
Weight [kg]
Sound level - Lp dB(A)*
1
2
3
1200
81.3
200
2.66
0.62
1.87
230-1-50
1700
720
1320
325
40
1700
81.1
200
3.9
0.89
1.89
230-1-50
1700
820
1320
350
42
2700
81.4
200
6.3
1.5
1.99
230-1-50
1800
990
1540
475
42
4
5
6
7
8
9
4100
5500
6100
7000
9100
11500
81.6
82.6
81.2
82.7
81.4
81.5
200
200
200
200
200
200
2.98
4
4.74
4.76
5.54
8.72
1.98
2.68
2.96
3.3
3.76
5.48
1.74
1.75
1.75
1.7
1.49
1.72
400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50 400-3+N-50
1920
2080
2280
2400
2450
2280
1200
1400
1400
1600
1940
1940
1740
1740
1920
1920
2180
2460
575
750
790
950
1330
1410
45
46
44
43
43
45
10
15000
83.2
200
10.2
7.04
1.69
400-3+N-50
2400
2300
2570
1750
45
* Sound pressure level radiated from unit at 1 meter and according to ISO 3744 (supply outlet ducted)
Main Unit
Size
1
2
3
4
Main Module
£7,228.00
£7,487.00
£8,415.00
£9,240.00
5
6
7
8
9
£10,066.00 £10,724.00 £11,872.00 £13,835.00 £15,882.00
10
£17,797.00
Size
Coil Module
Mixing Box
Roof
Mode
Coil’s Row
Cooling
Cooling+Heating
DX HP
6
6+2
4
1
2
3
4
5
6
7
8
9
10
£1,139.00
£1,624.00
£1,431.00
£1,251.00
£1,750.00
£1,480.00
£1,471.00
£2,003.00
£1,626.00
£1,755.00
£2,401.00
£2,428.00
£1,979.00
£2,661.00
£2,539.00
£2,377.00
£3,098.00
£2,726.00
£2,059.00
£2,815.00
-
£2,684.00
£3,529.00
-
£2,901.00
£3,480.00
-
£3,365.00
£4,816.00
-
Size
1
2
3
4
5
6
7
8
9
10
Three way mixing box
£606.00
£616.00
£661.00
£750.00
£797.00
£820.00
£948.00
£1,079.00
£1,175.00
£1,276.00
Size
1
2
3
4
5
6
7
8
9
10
Outdoor Kit (Roof )
£145.00
£159.00
£194.00
£246.00
£316.00
£332.00
£367.00
£447.00
£475.00
£533.00
Size
1
2
3
4
5
6
7
8
9
10
Filter Stage
M6 Filter (to replace G3 or G4)
Additional Filtration Module
F9 front withdrawal
£79.00
£799.00
£79.00
£822.00
£133.00
£963.00
£157.00
£1,117.00
£211.00
£1,231.00
£211.00
£1,346.00
£236.00
£1,569.00
£377.00
£1,852.00
£377.00
£2,171.00
£505.00
£2,306.00
Size
1
2
3
4
5
6
7
8
9
10
Heat Wheel
Sorption Type (to replace sensible
type on main module)
£695.00
£789.00
£998.00
£1,319.00
£1,504.00
£1,618.00
£1,936.00
£2,199.00
£2,627.00
£3,599.00
Size
Bacnet Module (for ITM Daikin)
1
2
3
4
5
6
7
8
9
10
Coms
Module
£157.00
Please contact your local sales office for further information on selection at different working conditions
and matched Daikin ERQ & VRV IV condenser units for DX applications
Price List 2016
187
APPLIED
* Price includes G4/G7 filtration, Mineral Wool Insulation, Aluzinc internal skin and Aluzinc or Pre-Painted external skin
Air Handling Units
Modular AHU application with Daikin DX condensers
Daikin fresh air package
High comfort levels
The Daikin fresh air package provides a complete solution,
including all unit controls (expansion valve, control box an AHU
controller) and sensors factory mounted and configured.
Daikin ERQ and VRV units respond rapidly to fluctuations in
supply air temperature, resulting in a steady indoor temperature
and resultant high comfort levels for the end user. The ultimate
is the VRV range which improves comfort even more by offering
continuous heating, also during defrost.
This unique solution allows for plug and play connection of our
AHU series to Daikin ERQ and VRV condensing units.
High efficiency
Daikin heat pumps are renowned for their high energy efficiency.
Integrating the AHU with a heat recovery system is even more
effective since an office system can frequently be in cooling
mode while the outdoor air is too cold to be brought inside in an
unconditioned state. In this case heat from the offices is merely
transferred to heat up the cold incoming fresh air.
VRV IV or ERQ
condensing unit
Expansion kit factory fitted and
integral to DX HP coil module
APPLIED
Expansion valve (EKEXV)
Please refer to pricing of our VRV IV (pages 71 - 73 and pages 76 - 83 and page 95) and
ERQ (Page 52) inverter driven condensing unit ranges which are compatible with the Modular AHU.
188
Residential, Commercial and Industrial
Electronic interface
(EKEQ)
Daikin UK Price List 2016
Services & Training
RW Fixings Guide
190
Service Department
192
Daikin Service Tools
195
Training196
Scottish
Region
0845 641 9330
198
Northern
Region
0845 641 9340
Midlands
Region
0845 641 9370
Western
Region
0845 641 9320
North
London
0845 641 9360
South
London
0845 641 9355
SERVICES & TRAINING
Terms & Conditions
Complete Range of Fixings
...now available at RW
FiG
FG
ixu
x
e
in
id
g
iunid
s
s
g
in
Fix
gse Gu
e
d
i
u
G
s
ide
Fixing
Rndi
e f rtion
Re fr&igAir
ing
Co
ein
ra
gtio
Ref rige rat ion
&igAeirraCto
n
io
iond
it
S
d
n &itiA
unp p
n
o
oir
Su
ni ng
C
p
p
ir
lie
li
A
e
rs
rs
Co n d
n &plie rs
Sup
e ra ti o
Re fr ig
rs
S u p p lie
w w w .r w
-w
www
ww w. rw -wk
.r w - w
h o le s
www .rw-w hole sale .co.u ho les al e. co .uk
a le .c
o .u k
k
.u
o
le .c
sa
le
o
h
it io n in
g
SERVICES & TRAINING
Call into your local branch for a copy today!
Refrigeration & Air Conditioning
Suppliers
www.rw-wholesale.co.uk
SERVICES & TRAINING
Call into your local branch for a copy today!
The Daikin UK Service Department
The Daikin UK Service department supplies a range of services to support our customers.
Pre-installation, commissioning and project support
Workshop
Commissioning
In our workshop in Bristol we modify standard Daikin equipment
to current specifications in order to meet our clients’ needs. We can
offer bespoke modifications to suit your exact requirements – please
speak to your sales engineer to discuss how we can help you.
Daikin UK offers a full commissioning service, which includes
the charging of additional refrigerant, setting up of all Daikin
control systems, operation testing and validation. A detailed
commissioning report is produced per system to aid you with
handover of the project. If you require dedicated support
throughout your project, we can now offer an extended service
to meet all your project requirements.
Typical modifications include:
> C
reating weather-proof enclosures for
VAM Total Heat Exchangers. See page 111
> Repainting indoor and outdoor units.
For VRV units, see page 69, for Sky units see page 41
> Customisation of controls
> Removing flair connections
> Strip and rebuilds. See page 69
> Blygolding. See below.
Strip and rebuild
Strip and rebuild offers the benefit of time and cost savings by
having VRV outdoor units delivered to site in portable components,
so they can be transported to the roof without the need for cranes
and road closure applications.
For larger projects, Daikin UK Service department offers complete
Project Support from the point of order to system handover. Our
service engineers will assist you throughout the project, providing
a dedicated contact for technical queries and support, installation
checks and commissioning.
As part of our Project Support service, we conduct surveys during
the installation to ensure it is installed to our specification and
rules, witness the strength/pressure test on the DX side, evacuate
the systems, charge with any additional refrigerant and configure
any ITM controls prior to commissioning.
For more information, see page 69.
Prior to project commencement, our service engineer will
meet with you to:
Blygold treatment for heat exchangers
> Discuss project time scales and schedule Daikin UK
engineer attendances
> Discuss potential installation restrictions/issues
> Identify potential issues and give advice on how to avoid
> Source copies of the site drawings
Daikin UK can offer additional treatment for Heat Exchangers to
protect against corrosion and pollution, ensuring the long term
efficiency of the units.
We can apply a Blygold treatment to the coil and fins. This is
recommended for salt laden air (coastal) projects or areas in which
high levels of pollutants can create a barrier between the air and
the heat exchanger.
Lead time: 2-3 weeks
Applicable units: All Condensers
Unit
Split Unit
SkyAir 71-140 Class
SkyAir 200-250 class
VRV Outdoor
SERVICES & TRAINING
Dedicated project support
192
Treatment Price (Excludes Unit Price)
£490.00
£540.00
£610.00
£725.00
Residential, Commercial and Industrial
Our service engineer will liaise with you throughout the project to
agree sign off dates, commissioning dates and schedules. We will
then commission the system, ensuring all systems are operating
correctly according to the site requirements.
Upon completion, a commissioning booklet is
produced including:
> Installation Certification Reports – number of reports depends
on number of checks
> Pressure/Strength Test Certificate
> Evacuation Verification Certificate
> Commissioning Reports
> F-Gas Log
If you would like Daikin UK Project Support, please speak to your
sales engineer who will liaise with service management team to
assign you a dedicated service engineer.
Post-installation, spare parts and service support
Aftersales technical helpdesk
Spare parts
This invaluable service offers technical support and guidance
when you are experiencing on-site problems when commissioning
or diagnosing faults. Final diagnosis is the responsibility of the
site engineer.
When a component fails, Daikin has over 13,000 spare parts based
in the UK, supported by our European parts centre with 700,000
parts. This helps us to achieve our target of delivering 97% of
critical A parts within two days.
For support with Air Conditioning systems,
please contact:
Tel 0845 641 9200
Mon - Fri 8.30 - 17.30
For support with Heating systems,
please contact:
Tel 0845 641 9277
Mon - Fri 8.30 - 20.00 & Sat 9.00 - 15.00
Email [email protected]
SMS Fault Code Service 07797 801908
If you need an explanation and remedy on a fault code and
haven’t got your service manual, just send the fault code to our
SMS message service and we will advise you by return.
Maintenance contracts
Commercial customers: if you would like Daikin UK to support
you with commercial maintenance contracts, we can offer a full
service package, including 24 hour support, for account holding
customers.
Domestic heating customers: Daikin UK offers comprehensive
heat pump maintenance as a premium after care service for Daikin
Altherma systems. All parts, labour and call-outs are covered in the
unlikely event of a heating or hot water failure.*
For total comfort and peace of mind, this heat pump maintenance
package also includes an annual maintenance visit, to help keep
your customers’ systems running efficiently throughout the year
and minimise the risk of any breakdowns.
Daikin UK also offers a basic heat pump maintenance package,
which entitles you to an annual maintenance visit, during which
our engineer will ensure that your Altherma heat pump is
operating within the optimum conditions to maximise energy
efficiency. Any potential issue can be dealt with by a Daikin
engineer. You will also be entitled to a discount on the cost of spare
parts and labour.
To contact the Spares team directly
Tel 0845 641 9230
Fax 0845 641 9299
Email [email protected]
If you hold a direct account with Daikin UK, you can send and
view your spare parts orders online using our Spare Parts Bank
– available 24 hours a day, 365 days a year. Plus, there are no
delivery charges on orders placed via the Spare Parts Bank,
which is equivalent to almost 5% extra discount.
To register for Spare Parts Bank go to www.daikin.co.uk/spares
Service support on-site
We can provide service engineers to assist you with on-site
commissioning or service support. All work is documented in
a report and sent for your records. So that we can give you the
best service possible, it is important to ensure that you are in
attendance at that time.
To book an engineer, please contact the Regional Service
office closest to the site where your equipment is installed:
Eastern Region Service Centre
Phone number
0845 641 9274
Operating Hours
Mon - Fri: 09.00 to 17.00
Email address
[email protected]
Western Region Service Centre
Phone number
Operating Hours
0845 641 9278
Mon - Fri: 09.00 to 17.00
Email address
[email protected]
Northern Region Service Centre
Phone number
Operating Hours
0845 641 9279
Mon - Fri: 09.00 to 17.00
Email address
[email protected]
Energy monitoring and auditing
Daikin UK offers an increasing range of energy monitoring and
auditing services, plus remote monitoring and prediction solutions
(DNSS). Please ask your sales engineer if you have a project that you
think may be suitable for including in an energy monitoring and
auditing trial.
*subject to t&c’s
Price List 2016
193
SERVICES & TRAINING
Your calls will be answered by Daikin trained engineers. To help
provide a quick and efficient response, please make sure you have
the full model number of the unit. It is important to remind you
that using the D1/D1+ PIN number gives you priority access to
our engineers.
Daikin UK warranties
Making a warranty claim
Daikin UK offers a range of warranties and extended warranties
for our Air Conditioning, Applied, Refrigeration and Heating
equipment.
If you have a component failure and it is within the warranty
period then we are here to help. After you have spoken to our
Technical Helpdesk to confirm diagnosis, you can simply contact
the warranty team.
Our warranties have been designed to meet the needs of our
customers and, as such, offer different terms for customers
belonging to our D1 partner programme, KEY heating installer
scheme and customers belonging to neither D1 nor KEY.
Our KEY heating installer scheme offers end-user warranties for
our domestic heating customers. Please see key.daikin.co.uk for
more information.
For all other customers - whether D1, D1+ or not yet a D1 partner
– we offer a commercial warranty. From April 2016, commercial
warranties are held between the installing contractor and Daikin
UK only (non transferable).
SERVICES & TRAINING
For detail on our warranties and how to claim, please see
www.daikin.co.uk or visit our business portal my.daikin.co.uk
for more information.
194
Residential, Commercial and Industrial
Contact the warranty team on:
Tel 0845 641 9275
Fax 0845 641 9299
Email [email protected]
Daikin Service Tools
Daikin Service App
Service checker (part no. 999165T)
The Daikin Service Application supports service engineers working
with Daikin VRV Equipment.
The service checker type 3 can read and record the operational
data from various Daikin equipment. This data consists of
thermistor readings, pressure sensor values, solenoid valve
operation, expansion valve pulses, operation modes etc.
Software version 1.53 or later is required for connection
to VRV IV systems.
It’s available for both android
and iPhone devices.
The application covers various
functions to help field engineers
to fault-find Daikin VRV
equipment . Service App
functions include:
Android functions
Fault Codes
VRV Additional Charge Calculation
Replacement PCB Dip Switch Settings
Pressure Transducer and Temperature Thermistor Checks
Outdoor Unit field settings include:
Fan Coil and BSVQ Box Count Check
Refrigerant Recovery Setting
Outdoor Unit Emergency Modes
VRV III & IV Short Test Run
There is also Daikin Altherma support for:
Fault Codes
Additional Refrigerant Charges
C Series Altherma Field Settings
Dip Switch Settings and much more...
iPhone functions
Fault Codes
VRV Additional Charge Calculation
Replacement PCB Dip Switch Settings
Pressure Transducer and Temperature Thermistor Checks
Outdoor Unit field settings include:
Fan Coil and BSVQ Box Count Check
Refrigerant Recovery Setting
Outdoor Unit Emergency Modes
VRV III Short Test Run
DChecker
The DChecker is a service tool used to capture operational data
from the following equipment, Split-Multisplit, Sky-Air & Altherma
products. This will record and graph all sensor data, PCB inputs &
outputs from indoor and outdoor units. From the operational data
this will help to identify any operational issue.
Please note the DChecker is a USB interface which provides a
direct wired link to the main PCBS and enables real-time data to
be viewed on a laptop running windows. Software included.
Inverter analyser RS UK0917A (part no. 136 8521)
The inverter analyser can be used to check the inverter outputs on
all VRV models (can also be used on various Split & Sky Air units).
To download the Apps go to:
Android:
https://play.google.com/store/apps/details?id=com.daikin.
aircon&hl=en
Price List 2016
195
SERVICES & TRAINING
iPhone:
https://itunes.apple.com/us/app/daikin-service/id571282882?mt=8
Daikin UK’s Customer Training
During 2016 we will continue to further invest in all our regional
training centres, hands-on training facilities and online resources,
to ensure that the training you receive is relevant to the everchanging market. By doing so, we aim to help you provide your
customers with the highest quality Installation, commissioning,
maintenance, service and fault-finding support.
Leading the way in R32 and R410A training
Daikin UK training centres
New hands-on training rigs for R410A or R32 Split systems are now
situated in all Daikin UK training centres. Purpose built R410A Sky
Air product training rigs can also be found at both our Woking and
Birmingham centres from March 2016. Attendees on our training
courses will get the opportunity to improve their operational
product knowledge and practice fault finding hands-on.
1 Bristol
Daikin Airconditioning UK Limited
Maple House, Brotherswood Court,
Great Park Road, Almondsbury,
Bristol BS32 4QW
With the introduction of R32 products into the UK market, and
the popularity of R32 training courses to date, we will be investing
further in our Woking Technology Centre during 2016, so that we can
offer hands-on R32 product installation and commissioning courses.
New Birmingham training centre
2 Woking
Daikin Airconditioning UK Limited
21 Woking Business Park, Albert Drive,
Woking, Surrey GU21 5JY
3 Birmingham
Daikin Airconditioning UK Limited
2470 Regents Court, The Crescent,
Birmingham Business Park,
Birmingham B37 7YE
4 Manchester
Daikin Airconditioning UK Limited
17b Cobra Court, Blackmore Road,
Manchester M32 0QY
5 Glasgow
Daikin Airconditioning UK Limited
Unit 2, Glasgow Airport Business Park,
Marchburn Drive, Paisley PA3 2SJ
6 PGL Training
Clyst Works, Clyst Road, Topsham,
Exeter EX3 0DB
Adjacent to our new Birmingham sales office, the Birmingham
training centre covers an area of over 200m2 and provides hands on
training on the latest Split, VRV, Altherma and control systems.
Woking Technology Centre
The Technology Centre in Woking is Daikin’s largest training facility
in the UK, over two floors, covering an area close to 1000m2.
The facility is able to hold three training events at one time, with
additional equipment demonstration facilities and a dedicated
suite for conducting Web based live training events.
SERVICES & TRAINING
The centre includes VRV Heat Recovery, VRV Heat Pump, Water
Cooled VRV, R22 Replacement VRV-Q, as well as a variety of Split
and Sky Air systems. A specially designed controls section has
been constructed to demonstrate the many different configuration
possibilities of individual and central controls together with the
many BMS interface options.
The first floor is dedicated to Heating products with eight individual
working bays containing a wide selection of systems to allow for
practical hands-on training of commissioning and fault diagnosis.
The award winning Altherma Hybrid system is installed in each of
these eight bays, so every attendee receives the highest quality
product training experience.
To find out when courses are scheduled at regional Daikin UK regional training centres and at PGL Training,
check availability and book a place: please go to the Daikin UK booking web site at www.daikintraining.co.uk
196
Residential, Commercial and Industrial
Online short courses
For anyone operating in the HVACR market, the skills and
knowledge required is getting greater every year. Daikin UK
recognises our training needs to keep pace with the demands on
people working in the industry – not least the pressures on your
time. So we are continually looking at new and innovative ways to
deliver the training you need.
During 2016 we are introducing a wider range of courses, together
with new web based short courses available on whichever online
or mobile platform you prefer.
Within our new Woking Technology Centre we have installed a
web based broadcast facility. From here we can provide short
courses across a range of subjects. The majority of these will also
be recorded and made available through our training website.
In response to valued customer feed back, we will also be
introducing short online refresher courses on specific products,
where previous product course attendance pre-requisites have
been fulfilled.
Users can register as an individual to undertake web based training
and each user has a training account that enables them to review
past training they have undertaken and print off training records
and certificates.
As these courses become available it will be possible to reserve
places at www.daikintraining.co.uk. We will announce more specific
details throughout the year.
Price List 2016
197
SERVICES & TRAINING
Our new courses will cover more application and design subjects,
legislation, technical topics and also personal development areas
such as presentation and selling skills.
RW Refrigeration Wholesale Ltd
Terms and Conditions
1 Price
4.3.5 recover (under clause 4.7) the cost of taking legal action to make you pay.
1.1 The price quoted excludes VAT (unless otherwise stated). VAT will be charged at the
rate applying at the time of delivery.
1.2 Our quotations lapse after 30 days (unless otherwise stated).
4.4 If you have an approved credit account we may withdraw it or reduce your credit
limit or bring forward your due date for payment. We may take any of these actions at
any time and without notice.
1.3 If your order is for goods less than £15.00 you will be charged a minimum invoice
charge of £15.00.
4.5 You do not have the right to set off any money you may claim from us against
anything you may owe us.
1.4 The price quoted includes standard next day delivery in Great Britain and Northern
Ireland (excluding the Scottish Highlands and Islands) by a method of transport selected
by us if the value of the goods ordered is £50.00 or more (unless otherwise stated.)
4.6 While you owe money to us, we have a right to keep any property we may hold of
yours until you have paid us in full (a lien).
1.5 The price quoted excludes express delivery or delivery within Great Britain and
Northern Ireland (excluding the Scottish Highlands and Islands) by a method requested
by you which is not usually used by us.
1.6 The price quoted excludes returnable cylinders. The cost of returnable cylinders will
be charged at the price current at the time of delivery unless they are returned to us
in good condition and within 30 days of receipt. The supply of returnable cylinders is
subject to our standard conditions from time to time in force.
5 Title
5.1 Until you pay all debts you may owe us:
1.7 Unless otherwise stated, the price quoted is an illustrative estimate only and the
price charged will be our price current at the time of delivery.
5.1.1 all goods supplied by us remain our property
1.8 Rates of tax and duties on the goods will be those applying at the time of delivery.
5.1.3 you must insure them (against the risks for which a prudent owner would insure
them) and hold the policy on trust for us
1.9 At any time before delivery we may adjust the price to reflect any increase in our
costs of supplying the goods.
5.1.2 you must store them so that they are clearly identifiable as our property
2.1 All delivery times quoted are estimates only.
5.1.4 you may use those goods and sell them in the ordinary course of your business,
but not if:
a. we revoke that right (by informing you in writing) or
b. you become insolvent.
2.2 If we fail to deliver within a reasonable time after the quoted delivery time, you may
(by informing us in writing) cancel the contract, however:
5.2 You must inform us (in writing) immediately if you become insolvent.
5.3 if your right to use and sell the goods ends you must allow us to remove the goods.
2.2.1 you may not cancel if we receive your notice after the goods have been
dispatched and
5.4 We have your permission to enter any premises where the goods may be stored:
2.2.2 if you cancel the contract, you can have no further claim against us under that
contract.
5.4.2 after your right to use and sell them has ended, to remove them, using reasonable
force if necessary.
2.3 If you accept delivery of the goods after the estimated delivery time, it will be on the
basis that you have no claim against us for delay (including indirect or consequential
loss, or increase in the price of the goods).
5.5 Despite our retention of title to the goods, we have the right to take legal proceedings
to recover the price of goods supplied should you not pay us by the due date.
2 Delivery
2.4 We may deliver the goods in instalments. Each instalment is treated as a separate
contract.
5.4.1 at any time, to inspect them and
5.6 You are not our agent. You have no authority to make any contract on our behalf
or in our name.
2.5 We may decline to deliver if:
6 Warranties
2.5.1 we believe that it would be unsafe, unlawful or unreasonably difficult to do so
6.1 We warrant that the goods:
2.5.2 the premises (or the access to them) are unsuitable for our vehicle or our carriers
vehicle or
6.1.1 comply with their description on our acknowledgement of order form and
2.5.3 you do not ensure that there is responsible person available to receive the goods
within a reasonable time of our arrival or our carriers arrival.
3 Risk
3.1 The goods are at your risk from the time of delivery.
3.2 Delivery takes place either:
3.2.1 at our premises (if you are collecting them or arranging carriage) or
3.2.2 at your premises or address specified by you (if we are arranging carriage).
3.3 You must inspect the goods on delivery. If any goods are damaged or not delivered,
you must write to tell us within five days of delivery or the expected delivery time. You
must give us (and any carrier) a fair chance to inspect the damaged goods.
4 Payment terms
4.1 You are to pay us in cash or in cleared funds on delivery, unless you have an
approved credit account.
4.2 If you have an approved credit account, payment is due no later than 30 days after
the date of our invoice unless otherwise agreed in writing.
4.3 If you fail to pay us in full on the due date we may:
4.3.1 suspend or cancel future deliveries
4.3.2 cancel any discount offered to you
SERVICES & TRAINING
4.7 You are to indemnify us in full and hold us harmless from all expenses and liabilities
we may incur (directly or indirectly and including finance costs, legal costs on a full
indemnity basis and the costs of instructing a debt collection agency to recover a
debt due to us if any) following any breach by you of any of your obligations under
these terms.
4.3.3 charge you interest at the rate set under s.6 of the Late Payment of Commercial
Debts (Interest) Act 1998
a .calculated (on a daily basis) from the date of our invoice until payment
b. before and after any judgment (unless a court orders otherwise)
4.3.4 claim fixed sum compensation from you under s.5A of that Act to cover our credit
control overhead costs and
198
Residential, Commercial and Industrial
6.1.2 are free from material defect at the time of delivery (as long as you comply with
clause (6.3)
6.2 We give no other warranty (and exclude any warranty, term or condition that would
otherwise be implied) as to the quality of the goods or their fitness for any purpose.
6.3 If you believe that we have delivered goods which are defective in material or
workmanship, you must:
6.3.1 inform us (in writing), with full details, within 7 days of becoming aware of the
failure
6.3.2 allow us and the manufacturer to investigate (we may need access to your
premises and product samples). We may request that you return the goods to us for
inspection at your own expense.
6.4 We may issue replacement goods to you while we investigate your claim. If so,
you must:
6.4.1 pay the price in full of the replacement goods to us and
6.4.2 pay the full price of the original goods to us (and accept their return) if , on
investigation, they are not found to be defective.
6.5 If the goods are found to be defective in material or workmanship (following our
investigations), and you have complied with those conditions (in clause 6.3) in full, we
will (at our option) repair the goods, replace the goods or refund the price subject to
clause 6.6 below.
6.6 As we are not the manufacturer of the goods, our liability is limited to the balance
of any benefit that we may receive under any manufacturer warranty or guarantee of
the goods.
6.7 Where goods are returned to us for repair or inspection under warranty:
6.7.1 you will pay the cost of sending the goods to us for repair or inspection
6.7.2 you must enclose with the returned goods a properly completed warranty claim
form or a site report form (if applicable)
6.7.4 you must ensure that the returned goods shall be free of external equipment and
that any openings are effectively sealed against ingress of foreign matter
6.7.5 if you are returning compressors you must ensure that they are fitted with the
appropriate electrical equipment and
6.7.6 you must return the goods to us within 21 days of the fault occurring.
9.5 You are responsible for arranging testing and inspection of the goods at our
premises before shipment (unless otherwise agreed). We are not liable for any defect
in the goods which would be apparent on inspection unless a claim is made before
shipment. We are not liable for any damage during transit.
9.6 We are not liable for death or personal injury arising from the use of the goods
delivered in the territory of another State (within the meaning of s.26 (3) (b) Unfair
Contract Terms Act 1977).
6.8 Where goods are returned to us for repair not under manufacturer warranty:
10 Cancellation
6.8.1 The price quoted for the repair excludes VAT (unless otherwise stated). VAT will
be charged at the rate applying at the time of the return of your repaired goods to you.
10.1 You may not cancel the order unless we agree in writing (and clauses 2.2.2 and
10.2 then apply).
6.8.2 Our quotations for repair lapse after 30 days (unless otherwise stated).
10.2 If the order is cancelled (for any reason) you are then to pay us for all stock (finished
or unfinished) that we may then hold (or to which we are committed) for the order.
6.8.3 The price quoted for repair excludes delivery of the goods to us and excludes
delivery of the repaired goods back to you (unless otherwise stated)
6.8.4 We will inform you if the goods are unrepairable. If you have not requested that
the unrepeatable goods be returned to you, you agree we can dispose of the goods
(without any liability to you) on 28 days written notice.
6.8.5 We will charge an inspection fee but will normally waive the fee if you instruct us
to repair the goods in accordance with our quotation.
10.3 We may suspend or cancel the order, by written notice if:
10.3.1 you fail to pay us any money when due (under the order or otherwise)
10.3.2 you become insolvent
10.3.3 you fail to honour your obligations under these terms.
11 Waiver and variations
6.9 We cannot accept liability in respect of any defect arising from fair wear and tear,
wilful damage, misuse, abnormal working conditions, failure to follow our instructions
or the guidelines for maintenance provided by us or the manufacturer, or the alteration
or repair of the goods without our or the manufacturers approval.
11.1 Any waiver or variation of these terms is binding in honour only unless:
6.10 We are not liable for any other loss or damage arising from the contract or the
supply of goods or their use, even if we are negligent, including (as examples only)
11.1.3 expressly stating an intention to vary these terms.
6.10.1 direct financial loss, loss of profits or loss of use And
6.10.2 indirect or consequential loss
6.11 Our total liability to you (from one single cause) for damage to property caused by
our negligence is limited to £750,000.
6.12 For all other liabilities not referred to elsewhere in these terms our liability is
limited in damages to the price of the goods.
6.13 Nothing in these terms restricts or limits our liability for death or personal injury
resulting from negligence.
11.1.1 made (or recorded) in writing
11.1.2 Signed on behalf of each party and
11.2 All orders that you place with us will be on these terms (or any that we may issue
to replace them). By placing an order with us, you are expressly waiving any printed
terms you may have to the extent that they are inconsistent with our terms.
12 Force majeure
12.1 If we are unable to perform our obligations to you (or able to perform them only
at unreasonable cost) because of circumstances beyond our control, we may cancel or
suspend any of our obligations to you, without liability.
6.14 The warranty is not transferable.
12.2 Examples of those circumstances include act of God, accident, explosion, war,
terrorism, fire, flood, transport delays, strikes and other industrial disputes and difficulty
in obtaining supplies.
7 Specification
13 General
7.1 If we prepare the goods in accordance with your specifications or instructions you
must ensure that:
13.1 English law is applicable to any contract made under these terms.
7.1.1 the specifications or instructions are accurate
13.3 If you are more than one person, each of you is liable for all of your obligations
under these terms (joint and several liability).
7.1.2 goods prepared in accordance with those specifications or instructions will be fit
for the purpose for which you intend to use them and
7.1.3 your specifications or instructions will not result in the infringement of any
intellectual property rights of a third party, or in the breach of any applicable law
or regulation.
7.2 We reserve the right
7.2.1 to make any changes in the specifications of our goods that are necessary to
ensure they conform to any applicable safety or statutory requirements and
7.2.2 to make without notice any minor modifications in our specifications we think
necessary or desirable.
8 Return of goods
8.1 We will accept the return of goods from you only:
8.1.1 by prior arrangement (confirmed in writing)
8.1.2 on payment of an agreed handling charge (unless the goods were defective
when delivered) and
8.1.3 where the goods and packaging are as fit for sale on their return as they were
on delivery.
9 Export terms
9.1 Clause 9 of these terms applies (except to the extent that it is inconsistent with
any written agreement between us) where we supply the goods over an international
border or overseas.
9.2 The Incoterms of the International Chamber of Commerce which are in force at
the time when the contract is made apply to exports, but these terms prevail over the
Incoterms to the extent that there is any inconsistency.
9.3 Unless otherwise agreed, the goods are supplied ex works our place of business.
13.2 The English and Welsh courts have non exclusive jurisdiction.
13.4 If any of these terms are unenforceable as drafted:
13.4.1 it will not affect the enforceability of any other of these terms and
13.4.2 if it would be enforceable if amended, it will be treated as so amended.
13.5 We may treat you as insolvent if:
13.5.1 you are unable to pay your debts as they fall due or
13.5.2 you (or any item of your property) becomes the subject of:
a. any formal insolvency procedure (examples of which include receivership, liquidation,
administration, voluntary arrangements (including a moratorium) or bankruptcy)
b. any application or proposal for any formal insolvency procedure or
c. any application, procedure or proposal overseas with similar effect or purpose.
13.6 All brochures, catalogues, technical literature and other promotional materials are
to be treated as illustrative only. Their contents form no part of any contract between us
and you should not rely on them in entering into any contract with us.
13.7 Any notice by either of us which is to be served under these terms may be served
by leaving it at or by delivering it to (by first class post or by fax) the others registered
office or principal place of business. All such notices must be signed.
13.8 No contract will create any right enforceable (by virtue of the Contracts (Rights of
Third Parties) Act 1999) by any person not identified as the buyer or seller.
13.9 The only statements upon which you may rely in making the contract with us are
those made in writing by someone who is (or whom you reasonably believe to be) our
authorised representative and either:
13.9.1 are contained in our estimate (or any covering letter) and not withdrawn before
the contract is made or
13.9.2 expressly state that you may rely on them when entering into the contract.
13.10 Nothing in these terms affects or limits our liability for fraudulent.
9.4 Where the goods are to be sent by us to you by a route including sea transport
we are under no obligation to give a notice under section 32(3) of the Sale of Goods
Act 1979.
Price List 2016
199
SERVICES & TRAINING
6.7.3 we will pay to return the repaired or replaced goods to you if the address is within
Great Britain
SERVICES & TRAINING
Notes
200
Residential, Commercial and Industrial
Daikin Air Conditioning Guide
Acton (London)
0208 896 9187
Bow (London)
0208 525 9888
Bristol
0117 977 2616
Birmingham
0121 328 1122
Chelmsford
01245 463 539
Dorset
01202 824 186
Edinburgh
01506 855 306
Exeter
01392 823 992
High Wycombe
01494 473 330
Hull
01482 974 500
Kent
01322 529 994
Nottingham
0115 986 6477
Daikin
Air Conditioning Guide
Issue 2
Daikin Air Conditioning
Suppliers
Daikin Air Conditioning
Suppliers
Refreshingly Different
Refreshingly Different
www.rw-wholesale.co.uk
www.rw-wholesale.co.uk
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement