AIPHONE | | 832809 TS-K1-02840
SPEAKER PHONE INTERCOM
MODELS: TS-6 K(6way)
TS-12K(12way)
— INSTRUCTIONS —
Handset microphone
(_ CONTROLS & FUNCTIONS ) Mandeer
andse
Directory card
D 29 0600600 Y BLE
Handset speaker
Call button
Paging button
Station selector buttons
Door release button
Privacy switch for loudspeaking
microphone
Loudspeaker
Terminal cord
Terminal box
Receiver cradle for wall mounting
Coil cord
Loudspeaking microphone
Case
Volume control
XDDD IO
( SPECIFICATIONS )
* Power source: DC 12 volt. Use PS-12S (PS-12C in North America) AC adaptor.
Current consumption: 150 mA maximum. |
Calling: Push button station selection. A single stroke chime sounds when call button is depressed.
Loudspeaking output: 200 mW maximum. | |
Paging: Use PG-U paging adaptor in conjunction with Aiphone paging amplifier: PG-A or PG-B and
speakers (or with PG-3 and a 8 ohm horn speaker). |
* Desk paging: Use desk paging adaptor PG-K with PG-U and paging amplifier. Output is approx. 300 mW
per station.
* Wiring: Up to 24 conductors may be required. Please refer to wiring diagram showing system that
meets your requirements. |
E о * %
( FEATURES )
*
Combination telephone and loudspeaking function. Either telephone conversation using handset at both stations or hands
free communication at receiving station is included.
Up to 13 stations can be connected in a system.
1 channel common talk system. Conference calls can selectively include up to 13 stations. |
* Paging system can be added using PG-U adaptor connected to Aiphone paging amplifier: PG-A or PG-B. Desk paging
(allows page message to be transmitted through loudspeaker at selected masters) is also available using PG-K adaptor.
* Designed for either desk use or wall mounting. |
* Privacy switch for loudspeaking microphone prevents. monitoring or eavesdropping by another master while in privacy
position.
* Volume controls for loudspeaker and tone call.
|
|
|
| ||
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
||
|
|
|
| |
1
|
|
|
|
|
|
|
|
|
|
|
|
Ш
\
| |
|
|
|
| |
||
| |
|
|
|
|
|
|
| |
|
| |
|
|
Ш
|
I
|
|
'
|
|
|
|
|
|
|
|
|
|
1]
|
| |
/
|
Ш
|
|
| |
| |
||
|
|
|
|
|
|
|
|
|
|
/
|
MI
|
|
|
| | |
|
|
|
|
|
|
|
|
|
|
' |
|
Ш
|
|
|
i
|
|
ı
|
|
||
|
|
i
hi
|
|
|
| |
|
|
| |
|
|
|
|
|
| |
|
|
|
|
|
||
||
||
||
|
|
|
|
|
|
|
Ш
i
{ll
|
|
i
I
|
|
|
|
|
|
|
i)
|
|
|
|
|
|
|
|
|
|
il
| |
|
|
| |
|
|
‘|
I
|
|
|
|
|
| |
||
|
|
| |
|
Л
|
|
|
||
|
|
|
A
|
||
|
|
|
|
| |
ll
| |
|
|
|
| |
|
|
И
|
Ш
|
|
|
'
|
|
|
|
|
| |
mn
|
|
||
i
|
|
|
|
"
|
| /
|
|
| |
|
Tr ii
il
|
|
|
|
| |
i
|
|
|
|
| |
|
|
i
li
|
|
|
a
i
|
|
|
|
|
|
|
|
|
||
|
|
|
|,
|
|
|
|
|
| |
|
| |
|
||
|
| |
|
|
|
||
|
|
|
|
|
|
|
Ш
|
| |
|
|
|
| |
|
|
|
I
|
|
|
|
|
|
|
|
|
|
|
|
| |
| |
|
|
|
|
|
|
fl |
|
|
|
|
|
| |
|
|
||
|
||
|
|
|
|
|
| |
|
|
N
|
|
|
|
|
|
|
|
|
|
I
I
|
|
|
|
|
|
|
|
|
|
| |
Ц
|
|
/
|
|
I
|
Ш
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
||
|
|
|
|
I
|
| ||
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| | |
|
|
|
|
|
||
|
|
|
yl
ill
|
|
|
|
IN,
|
|
|
|
| |
|
|
|
|
||
|
| |
|
|
|
|
|
|
|
|
I
|
|
I
iI"
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
||
| |
||
| | |
|
|
|
|
|
| |
|
|
|
|
|
|
||
|
|
|
|
|
|
|
|
|
|
|
|
|
(à
|
|
|
fil
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
] |
|
|
|
| |
|
|
|
||
| ||
!
| |
|
|
|
'
|
|
|
|
|
|
|
|
/
|
Ш
|
| |
|
Il
|
|
||
| |
|
||
Т
| |
||
|
||
|
|
|
|
|
|
|
|
|
!
|
qu
|
| |
|
| | |
|
| | |
| |
| |
|
|
|
|
|
|
|
|
i
‘ |
|
|
I]
|
|
|
|
|
|
|
|
||
|
|
|
|
* Door opener button can be used for remote control of door release. Other remote functions such as switching on outside
lights etc., can be accomplished using a proper relay.
* Excellent voice fidelity.
Door station IB-DA, etc. can be installed with adaptor DS-B. (Up to two door stations may be connected to up to 4
masters.)
* Block paging and talkback paging is available when using PA-B adaptor.
( INSTALLATION )
Do not attempt to install your intercom system until you have read and thoroughly understood the installation pro-
cedure. Aiphone’s warranty is void if system is installed in a manner other than described in this manual.
Lay out your system in advance. Determine the exact location of each station.
We recommend a full complement of wire be installed, even though you may not initially be installing the maximum
number of stations available for your system. This way, should you decide to add a station later, you can avoid running
additional cables to existing stations. Do not connect wires to terminals CS, ED, or P3 unless appropriate equipment is used.
Speaker phone will not operate if these wires are connected parallel through system.
A maximum of 24 conductors is required for the TS-12K. A maximum of 18 conductors is required for the TS-6K.
Refer to the chart below and select the proper wire gauge to meet your requirements.
AWG WIRE SIZE | 24 AWG 22 AWG 20 AWG 18 AWG
DISTANCE 550‘ 700 775° 875’
DIAMETER OF WIRE 0.5mm 065mm | 0.8mm 1.0 mm
DISTANCE 200 m 250m | 280m 320 m
Begin your installation with station #1. A space is provided at the left of the diagram to write in your color code.
Note the position of the C terminal at each station. Be sure you wire each station correctly.
After installing your second station we recommend that the power supply be connected to the + and — terminal lines at
a convenient location and that a test be made for calling and talking between each station. As each additional station is
installed retest between each station. Unplug power supply while making wiring connections. |
( ACTUAL TS-12K STATION TERMINAL LOCATION: )
O © MO
UD VOEDE
for connecting relative stations.
for power supply.
a
for talking and to be connected in common.
lo 5
| ЕЕ a5 com
for receiving call and talking.
for accessory functions added to system
at later date.
: for connecting door station.
©
for paging connection.
>
for door release or other remote control.
>
( INSTALLATION FOR WALL MOUNTING )
1) Attach the mounting bracket to wall or single gang plaster
ring.
2) Remove the rubber feet from base of station.
3) Attach the handset cradle with supplied screws.
( INSTALLATION OF TERMINAL BOX
(Can be mounted easily to wall or single gang box.)
1) Remove a screw and cover as shown.
. 2) Attach bottom case to wall or single gang box.
3) Wire terminals and replace cover.
TERMINAL IDENTIFICATIONS
—2—
(_EQUIPMENT AVAILABLE FOR USE WITH YOUR TS-K SPEAKER-PHONE )
TS-6K: 6 call master station. Up to 7
masters may be connected.
TS-12K: 12 call master station. Up to
13 masters may be connected.
DS-B: Adaptor for door station.
IB-DA: Door station. Please see below
for other types of door stations.
EL-9S: Electric door release. Requires
separate transformer.
PA-B: Talkback paging and/or block
paging adaptor,
PG-K: Desk paging adaptor. Allows page
to be heard through all other connected
stations. Must be used in conjunction
with paging amplifier.
PS-12C: CSA & UL approved power
supply (available only in North America).
PS-12S: Power supply for system.
Available everywhere except in North
America.
7
SP-3: Paging speaker. Complete and
ready to install including round flush
mounting frame. Transformer installed
for 70V line operation. (Either N-S,
square frame or N-E, round frame is
available for SP-3 installation).
PG-U TYPE A: Paging adaptor for con-
necting any amplifier and background
music source to your TS-K system.
Features paging volume, treble £ bass
controls and automatic background music
cut out.
RY-P: Relay for local speaker cut out.
Local speaker cut out eliminates the
chance of feed back if a paging speaker is
located near station initiating page.
PG-3: 3-watt paging amplifier.
PG-10A, PG-30A, PG-60A: UL & CSA
approved paging amplifier. 10W, 30W,
60W.
PG-10B, PG-30B, PG-60B: Standard
paging amplifier. 10W, 30W, 60W.
(_TS-K SYSTEM WITH TWO DOOR STATIONS CONNECTED )
Maximum of 2 door stations per system. Each door station may be connected to up to 4 masters.
STATION STATION
1 2
STATION STATION
3 4
TS-6K
DS-8
—
DOOR STATION
IB-DA
©
= | кю о оО
®
< |5 © 11] ||
= lwolalslo
00 ~ U
mw — TU
0 ~ U
PS-12S
or
PS-12C
NOTE: Please select the most suitable door station from your application from the IB-series door stations (IB-FY not available
in U.S.A).
1B-DA IB-NA IB-RA
STATION STATION STATION STATION
2 3 . 4
гп о —- о — 5 ==
С
2
3
4
5
6
7
8
9
©
3COT-OO Z-D—=
nl
то оО
mXm:I
STATION STATION STATION STATION STATION STATION STATION
1 | 1 fe |. 4 4 : Do
Mi — го =
© со On о ю С)
2 eek
Lad Nm 9
W
|
R
|
N
G
C
O
L
O
U
R
mOOO
mono
STER SYSTEM
\TION STATION STATION STATION STATION STATION STATION
9 10 11 12 13
AIPHONE
Power Supply
| PS—12C
” or
PS—12S
ith PAGING and DES
K PAGING
STATION STATION STATION STATION STATION STATION
| ; “Mi 10 TRE Ш ВР 13
E `В 7 = ; E TO PAGING
SPEAKERS
PAGING AMP.
PG-A or PG-B
O
С
— BACKGROUND
MUSIC SOURCE
70V LINE
— 5 PS-12C or PS-12S
( ALL MASTER INTERCOM SYSTEM WITH PAGING AND LOCAL SPEAKER CUTOUT )
STATION STATION STATION STATION STATION STATION STATION
1 2 3 4 5 6 7
ei
PG-U TYPEÁ
PAGING AMP,
PG-A or PG-B
QO
с
= BACKGROUND
MUSIC
SOURCE
moO OO ооо © — по = оо бо— — хо Ж
mm mT
PS-12C
or
PS-125
|] POWER SUPPLY
ul С
(_ PAGING WIRING REQUIREMENTS: )
a) 4 wires between PG-U and TS-K stations.
b) 5 common wires plus number of installed stations between TS-K stations,
с) A single pair of wires between PG-U and amplifier.
d) A single pair of wires between PG-U and background music source.
e) Paging speaker line must be run separately from station wires.
BL
ACK YELLOW
—
(_TO CUT OUT LOCAL SPEAKER DURING PAGING OPERATION )
Install relay RY-P between local speaker and TS-K station as shown with No. 2 station in the above wiring diagram.
Local speaker cut out eliminates the chance of feedback if paging speaker is located near station initiating page. (Yellow
wires from RY-P connect to paging speaker.) RY-P must be located at the speaker.
(INSTALLING PAGING SPEAKERS >
1) For ceiling or wall mounting, cut hole according to type of speaker chosen.
2) Install mounting hardware with screws provided. For mounting on concrete or other hard surface use suitable anchors for
attaching mounting frame.
3) Connect single pair of twisted wires to Paging amplifier.
4) Attach speaker to mounting frame by inserting studs into slots of mounting frame, aligning red arrow on baffle with red
screw and turning baffle clockwise until properly locked.
SP—3 SP—3 w/NS frame SP—3 w/NE frame
1
CIDE >
TRANSFORMER TERMINAL
LOCATION ON SP-3
3 (0.5 Watt)
2 (1 Watt)
1 (1.5 Watt)
SP-=3
NM
O (Com.)
Note: Aiphone SP-3 comes complete with baffle and mounted transformer.
— 6 —
Wire paging speakers referring to the table shown below. Total output of speakers must not be more than the rated
output of the paging amplifier used.
| RATED TRANS- SPEAKER OUTPUT | SPEAKER OUTPUT
FORMER OUTPUT TERMINAL CONNECTION 70.7V LINE 100V LINE
0 — 3 (10K ohms) 0.5 watt 1 watt
1.5 watts (70.7V LINE) —
SP-3 0 — 2 (5K ohms) 1 watt 2 watt
3 watts (100V LINE)
0 — 1 (3.3K ohms) 1.5 watt 3 watt
* Desk paging system can be added to an existing paging system by installing the PG-K adaptor, allowing paging announce-
ment to be heard through both paging speakers and loudspeakers of stations (desk paging).
*
Output for desk paging is 300 mW per station, so if 10 stations are connected for desk paging, 3 watts total is required. In
this example, 3 watts must be deducted from the total output of the paging amplifier used.
Example: Paging Amplifier 30 watt
Less 3 watt consumed by desk paging.
27 watt available for balance of paging system.
TS-K SPEAKER-PHONE SYSTEM WITH TALKBACK PAGING, ZONE PAGING, OR BOTH N
EQUIPMENT REQUIREMENTS J
1) TS-K system consists of TS-6K or TS-12K speaker phone powered by PS-12C or PS-12S power supply. PG-K desk paging
adaptor can also be installed. However, PG-K can not be wired for talkback paging.
2) One PG-U TYPE A, one PA-B, one paging amplifier with either 70 volt or 100V line and output of less than 50 watt RMS,
and appropriate paging speakers are required for each talkback zone.
a. If PA-B is installed for zone paging without talkback, amplifier is not limited to 50 watts.
For the full information, please refer to PA-B instruction sheet.
This example shows 3 areas of talkback paging. Selector
button #6 on each phone operates block #3. You may
page all 3 blocks (all page) by depressing selector button
#4, #5 and #6.
, TO PHONES
ор
RP,
- PG—U
[= A TYPEÁA
PAGING AMP.
PGA or PGB BLOCK?
_ STATION STATION STATION STATION
PAGING AMP.
ETN
с PG-A or PG-B BLOCK3
28 2 - ”
30 с [ 5 -
o 3 Bop pp С]
4 0 4 (FF РР, HR RB
5 5 5
5 5 5 6 ) (To ame PA—B
MO M м =
cs® cso cs@
Е © EQ Е ©
Es ® EJO EJO ()_() | Backorouno
Р, © Рю P — MUSIC SOURCE
P.O РО! P,
PO PQ PO
80 80 80 PS-125
B® 80 B® or
+0 +0 + PS-12C
- © - © m5 1 = POWER SUPPLY
——— —
( WIRING DOOR RELEASE EL-9S ) (Locked door is released by pushing door opener button on TS-K master station).
AVAILABLE CYLINDRICAL LOCKS
Vad EL—9S The bolt width
should be within
P3 © > 13/32”.
EL—9S e
B
B
WITHIN
+ A 167
-95 O
2 т EL-95 CYLINDRICAL X
- rans. LOCK 4
WITHIN
Separate bell transformer (not supplied by 135”
TS-—K terminal. Aiphone) required to power door lock. С 7
( OPERATION )
* Calling:
Pick up the handset and depress the selector button of desired station, then depress call button or call by direct voice.
* Receiving:
An incoming call is announced by a single stroke chime or by voice.
A reply can be made privately by using handset or hands free by using open voice speaker.
Volume control for loudspeaker is located on base of each master station.
* Monitoring:
Depress the selector button of desired station. Any master can monitor any other station if the selected station is not in
privacy position.
( PAGING OPERATION )
* Pick up the handset and make announcement pushing the paging button. Release paging button after completing an-
nouncement. Background music will automatically cut out during paging operation.
(CLEANING YOUR INTERCOM STATIONS )
* Your Aiphone intercom stations may be cleaned with a soft cloth dampened with household cleanser, such as Mr. Clean or
Fantastik.
*® kK
We at AIPHONE are proud of our products. Our designers and engineers strive to bring you the finest in
communication equipment. Each item has been carefully tested and inspected before leaving our factory. Properly
installed and used, your Aiphone intercom system should give years of trouble-free service.
We are pleased to offer the following warranty:
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal
use and service for a period of one year after delivery to the ultimate user and will repair free of
charge or replace at no charge, should it become defective upon which examination shall disclose
to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final
decision whether there is a defect in materials and/or workmanship; and whether or not the prod-
uct is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect,
accident, or to use in violation of instructions furnished, nor extended to units which have been
repaired or altered outside of the factory.
This warranty does not cover batteries or damage caused by batteries used in connection with the
product.
This warranty covers bench repairs only, and any repairs must be made at the shop or place des-
ignated in writing by Aiphone. Aiphone will not be responsible for any costs incurred involving on
site service calls.
FR TT Tp er
TT. Y + ETT
ан НЯ a
a bte Lo ?
PENE а Що
FAR lé
+
Aiphone Co., Ltd., Nagoya, Japan ALL OVER THE WORLD Al PHONE”
Aiphone Corporation, Bellevue, Washington
TS—K1-0284 Ú — 8 — PRINTED IN JAPAN(E)

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement