- Home
- Domestic appliances
- Floor care
- Vacuum cleaners
- Air King
- AKCV1225, AKCV1380, AKCV1310
- Operating manual
- 5 Pages
Air King AKCV1225, AKCV1380, AKCV1310 Central Vacuum Operating Manual
Air King AKCV1310 is a central vacuum cleaner designed to be permanently mounted in one location, with connections made to the living area with a network of inlets and tubing. It has a 120-volt AC motor and requires a dedicated, grounded electrical outlet of 120 volts AC, 60 Hz, 15 amp circuit. The AKCV1310 is designed to be used on a nominal 120-volt circuit and has a grounding plug. Make sure that the unit is connected to an outlet having the same configurations as the plug. No adapter should be used with this unit.
advertisement
Assistant Bot
Need help? Our chatbot has already read the manual and is ready to assist you. Feel free to ask any questions about the device, but providing details will make the conversation more productive.
IMPORTANT INSTRUCTIONS -
OPERATING MANUAL
Models AKCV1225,
AKCV1380, AKCV1310
Central Vacuum
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
1.
Read all instructions before installing or using the central vacuum.
2.
Use this central vacuum only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electrical shock, or injury to persons.
WARNING:
DO NOT DEPEND UPON THE UNIT’S CONTROLS AS THE
SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING.
ALWAYS UNPLUG THE UNIT.
3.
Before servicing or cleaning the unit, unplug the unit.
4.
Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including firerelated construction.
5.
Make certain that the power source conforms to the electrical requirements of the unit.
CAUTION:
THIS UNIT MUST NOT BE USED IN POTENTIALLY
DANGEROUS LOCATIONS SUCH AS FLAMMABLE, EXPLOSIVE, CHEMICAL-
LADEN OR WET ATMOSPHERES.
6.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
CAUTION:
EXHAUST SHOULD NOT BE VENTED INTO A WALL, CEILING,
OR CONCEALED SPACE WITHIN THE HOME.
7.
This unit is not intended for use on wet or outdoor locations, flammable or combustible liquids, burning or smoking items such as cigarettes, matches, or hot ashes.
8.
The central vacuum must be grounded as a precaution against possible electrical shock.
9. Do not use with damaged cord or plug.
10. Do not insert any objects into openings other than acceptable hose connections.
11. Use extra care when vacuuming on stairs.
12. To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall spray, construction dust, etc. off power unit.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
ELECTRICAL REQUIREMENTS
WARNING:
IMPROPER CONNECTION OF THE EQUIPMENT-GROUNDING
CONDUCTOR CAN RESULT IS A RISK OF ELECTRIC SHOCK. CHECK WITH A
QUALIFIED ELECTRICIAN OR SERVICE PERSON IF YOU ARE IN DOUBT AS TO
WHETHER THE OUTLET IS PROPERLY GROUNDED. DO NOT MODIFY THE PLUG
PROVIDED WITH THE UNIT- IF IT WILL NOT FIT THE OUTLET, HAVE A PROPER
OUTLET INSTALLED BY A QUALIFIED ELECTRICIAN.
WARNING:
THIS UNIT IS FOR USE ON A NOMINAL 120 VOLT CIRCUIT
AND HAS A GROUNDING PLUG. MAKE SURE THAT THE UNIT IS CONNECTED
TO AN OUTLET HAVING THE SAME CONFIGURATIONS AS THE PLUG. NO
ADAPTER SHOULD BE USED WITH THIS UNIT.
This unit requires a dedicated, grounded electrical outlet of 120 volts AC, 60 Hz,
15 amp circuit.
SAVE THESE INSTRUCTIONS
www.airkinglimited.com
000000 Rev A. 3-05 1 of 16
INSTALLATION INSTRUCTIONS
1. Unpack central vacuum power unit from the carton and confirm that all pieces are present. In addition to the power unit you should have:
1 - Power unit mounting bracket
1 - Inlet valve
1 - Instruction/Safety Sheet
Planning the Installation
The Air King Central Vacuum System consists of three major components. The power unit, fittings including the inlet valves and tubing, and the tool kit. The power unit is designed to be permanently mounted in one location with connections made to the living area with a network of inlets and tubing.
Locating the Power Unit
1. The power unit can be located in a garage, basement, utility room, or any other room that allows for sufficient ventilation, is dry, and provides accessibility to the unit for emptying the collection canister.
CAUTION:
IF THE POWER UNIT IS INSTALLED IN A CLOSET OR
UTILITY ROOM, IT MUST BE VENTED TO PROVIDE ENOUGH AIR FLOW.
LOUVERED DOORS CAN BE USED. DO NOT MOUNT IN A HIGH AMBIENT
TEMPERATURE AREA SUCH AS ATTIC, FURNACE ROOM, ETC.
NOTE: If venting the unit to the outdoors, avoid venting to areas such as patios or entranceways.
2. The power unit should be mounted within 5 feet of an acceptable outlet.
Check the electrical specifications of your specific unit to ensure the circuit is not being overloaded. A dedicated 15 amp circuit should be used.
Locating the Inlet Valves
1. The number of inlet valves will be determined by the layout of your home.
The hose must be able to reach every corner of the home including inside closets and around furniture. Inlets should be placed in central locations and avoid placing behind furniture or doors.
2. Using a 30 foot piece of string or the hose itself, have one person hold one end to the planned inlet location and have the second person walk around the room(s) to determine if more inlets are needed. Continue this exercise until you can reach every area of the home (Figure 1).
Power
Unit
Bedrm Bedrm Bedrm
Bath
Hall
Living
Room
45° Elbows
Obstruction
Trunk Line to
Power Unit
Stop
Coupling
Branch
Line
Trunk Line to last Inlet
Figure 2
2. Branch lines join the remaining inlets to the trunk line and can be run through walls, closets, cold air return duct, etc. As with the trunk line, branch lines should be kept at straight as possible.
3. Avoid gravity drops in the branch line. A branch line located directly below an overhead trunk line will accumulate dirt due to the effects of gravity. The result will be a pile of debris at the base of the inlet valve each time it is opened (Figure 3).
Debris
Correct
Wrong
Figure 3
CAUTION:
MAKE SURE TUBING WILL NOT OBSTRUCT OR INTERFERE
WITH ELECTRICAL, PLUMBING, OR OTHER MECHANICAL INSTALLATIONS.
Installation into New Construction
Installing the Inlet Valves
1. Using flush mounting screws (not provided) install the appropriate inlet mounting plate to the wall stud (Figure 4).
Model CVIV70
Standard Inlet
Mounting Plate
45° Wye
Trunk Line
Garage
Kitchen
Figure 1
3. If the installation is for new constructions and you are working with 1/4" scale blueprints, use a seven inch string to represent the hose.
NOTE: If an electrical tool kit with a corded hose will be used, make sure an electrical outlet is located within 5 feet of the inlet.
Planning the Tubing System
1. The tubing system will include a main trunk line that will flow from the furthest wall inlet back to the power unit and can be run through the basement or the attic (Figure 2). The trunk line should be kept as straight as possible to maximize the unit performance. When elbows are needed
45° fittings should be used or if a 90° connection is required, a sweep elbow should be used.
Model CVIV65
Electric Inlet
Mounting Plate
Model CVIV80
Plaster Guard
Figure 4
NOTE: Installation height will depend on personal preference, but generally the inlet is installed 18" above the finished floor.
2. To protect the system during the drywall phase of construction, an optional
CVIV80 plaster guard can be utilized and should be installed at this point.
000000 Rev A. 3-05 www.airkinglimited.com
2 of 16
Installing the Tubing
NOTE: When installing the tubing, start at the farthest inlet and work towards the power unit. Keep the tubing as straight as possible with the least amount of elbows and tees as possible to ensure maximum performance of your system.
When installing tees or elbows, make sure the curve in the fitting is aligned so that the air flow is towards the power unit.
1. Cut a 2-1/2" diameter hole in the sole plate, header, or stud directly in line with the opening of the inlet fitting (Figure 5).
Installing Wall Inlet Models CVIV60A or CVIV60W
CAUTION:
INSTALLATION WORK AND ELECTRICAL WIRING MUST
BE DONE BY QUALIFIED PERSON(S) IN ACCORDANCE WITH ALL APPLICABLE
CODES AND STANDARDS, INCLUDING FIRE-RELATED CONSTRUCTION.
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE STARTING INSTALLATION.
1. Once the drywall has been completed, the wall inlets can be installed. Start by checking the mounting plate for any debris that might have been left from the drywall process and clean if necessary.
2. Connect the low voltage wire to the terminal screws on the rear of the wall inlet (Figure 11).
2-1/4"
Figure 5 Figure 6
2. Measure the length of tubing needed to connect into the main trunk line, adding approximately 3/4" of tubing for insertion into fittings.
3. Cut the tubing, taking care to keep the straight square edge. The use of a miter box is recommended (Figure 6).
4. Remove rough edges with a utility knife or coarse sand paper (Figure 7).
Extra wire for inlet connection
Low
Voltage
Wire
Figure 7
Figure 9
Tape
8. Insert tubing with cement into fitting with a twisting motion to ensure the cement has been evenly spread. Check that the tubing is evenly seated in the fitting and is aligned properly with the rest of the line (Figure 10).
000000 Rev A. 3-05
1"
Cement
Figure 8
5. Dry fit all pieces and ensure proper fit and alignment before cementing.
6. When dry fitting tubing, run low voltage wire (minimum, solid 18 gauge, two conductor) by securing to tubing with tape. Allow approximately 6" of excess wire for connection to each inlet (Figure 8).
NOTE: PVC solvent cement “welds” the fitting to the tubing through a chemical reaction to produce an air tight seal. It is important to make sure all surfaces are clean and free of burrs to ensure a proper seal.
7. Once all tubing has been cut, cleaned, and checked for fit, apply model
CVFA35 PVC cement (not included) or equivalent cement to the outside of the tubing covering about 1". DO NOT allow any of the cement to enter the inside of the tubing (Figure 9).
Cement
Applicator
Figure 10
Figure 11 Figure 12
3. Align the inlet screw holes with the mounting plate holes and press the inlet into place, guiding any extra wire back through the mounting plate as you go. Attach wall inlet to mounting plate with provided screws (Figure 12).
Installing Electric Wall Inlet Models CVIV65A or CVIV65W
CAUTION:
INSTALLATION WORK AND ELECTRICAL WIRING MUST
BE DONE BY QUALIFIED PERSON(S) IN ACCORDANCE WITH ALL APPLICABLE
CODES AND STANDARDS, INCLUDING FIRE-RELATED CONSTRUCTION.
CAUTION:
MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL
BEFORE STARTING INSTALLATION.
1. Before the drywall is installed, run wire from a nearby electrical outlet box or junction box through the supplied strain relief and into the hole in the mounting plate, leaving about 10" of excess to make the connections to the inlet. Secure the wire in place by tightening the strain relief (Figure 13).
Low
Voltage
Wire
Supply
Wires from
Electrical Box
Figure 13
Strain
Relief
Figure 14 Wire Nut
2. Cap the loose wires and tuck back inside of mounting plate. Once the drywall has been completed the wall inlets can be installed. Start by checking the mounting plate for any debris that might have been left from the drywall process and clean if necessary.
3. Connect the low voltage wire to the terminal screws on the rear of the wall inlet. Second connect the black wire from the supply to the black wire of the inlet, then connect the white wire from the supply to the white wire of the inlet. Use approved electrical wire nuts for all connections (Figure 14).
4. Align the inlet screw holes with the mounting plate holes and press the inlet into place, guiding any extra wire back through the mounting plate as you go. Attach wall inlet to mounting plate with provided screws (Figure 12).
NOTE: The electrified wall inlet should be listed on the inspection report for building inspection purposes.
www.airkinglimited.com
3 of 16
Installation into Existing Construction
Installing the Inlet Valves
1. Once the desired location of the inlet has been determined, drill a small pilot hole through the subfloor directly below the center of the inlet and as close to the wall as possible (Figure 15).
Drywall
Sole Plate
Figure 15
4-3/8"
2-1/2"
Tubing
Pilot
Hole
Baseboard
18"
2-1/2"
Hole
2-1/4" +
Figure 16
2. From below, locate the pilot hole and measure over approximately 2-1/4"
(1/2" for the drywall + 1-3/4" to the center of a standard 2" x 4" sole plate).
Add extra for any additional material such as baseboards, thicker drywall, etc. Using a 2-1/2" hole cutter, drill through flooring and sole plate. Using a flashlight, inspect the interior of the wall to confirm that there are no obstructions (Figure 16).
NOTE: Installation height will depend on personal preference, but generally the inlet is installed 18" above the finished floor.
3. After confirming that there are no obstructions within the wall, cut a 2-1/2" x 4-3/8" hole in the wall at the desired wall inlet location (Figure 17).
Break Off
Tab
Pilot
Hole
Figure 17 Figure 18
4. Remove the perforated section of the mounting plate (Figure 18) and cement a model CVFE90S short 90° elbow to the mounting plate, facing the correct direction to make the connection to the tubing (Figure 19) (see step 7 in
Installing the Tubing section for cementing instructions).
8. Align the inlet screw holes with the mounting plate holes and lightly press the inlet into place, guiding any extra wire back through the mounting plate as you go. Attach wall inlet to mounting plate with provided screws making sure mounting plate is properly seated in hole (Figure 12).
NOTE: Do not cement wall inlet to mounting plate, the built in mounting plate gasket will provide a positive seal.
Installing the Tubing
NOTE: When installing the tubing, start at the farthest inlet and work towards the power unit. Keep the tubing as straight as possible with the least amount of elbows and tees as possible to ensure maximum performance of your system.
When installing tees or elbows, make sure the curve in the fitting is aligned so that the air flow is towards the power unit.
1. Measure the length of tubing needed to connect into the main trunk line, adding approximately 3/4" of tubing for insertion into fittings.
2. Cut the tubing, taking care to keep the straight square edge. The use of a miter box is recommended (Figure 6).
3. Remove rough edges with a utility knife or coarse sand paper (Figure 7).
4. Dry fit all pieces and ensure proper fit and alignment before cementing.
5. When dry fitting tubing, run low voltage wire (18 gauge, two conductor) by securing to tubing with tape. Allow approximately 6" of excess wire for connection to each inlet (Figure 8).
NOTE: PVC solvent cement “welds” the fitting to the tubing through a chemical reaction to produce an air tight seal. It is important to make sure all surfaces are clean and free of burrs to ensure a proper seal.
6. Once all tubing has been cut, cleaned, and checked for fit, apply model
CVFA35 PVC cement (not included) or equivalent cement to the outside of the tubing covering about 1". DO NOT allow any of the cement to enter the inside of the tubing (Figure 9).
7. Insert tubing with cement into fitting with a twisting motion to ensure the cement has been evenly spread. Check that the tubing is evenly seated in the fitting and is aligned properly with the rest of the line (Figure 10).
Installing the Power Unit
1. Determine a mounting location within 5 feet of a grounded electrical outlet and install the included mounting bracket (located inside of collection canister during shipping) using at least two appropriate screws (not included) for the wall material (Figure 21). The bracket must be level and mounted high enough to allow a minimum of 18" from the floor to the bottom of the collection canister.
Power Unit
Bracket
AKCVM1 Sound
Muffler
Cross
Bolt
Mounting
Bracket
Exhaust
Intake
Mounting Plate
Figure 19 Figure 20
5. Tape the low voltage wire (minimum, solid 18 gauge, two conductor) to the end of a sufficiently long enough piece of tubing and pass it up through the previously drilled hole (Figure 8).
6. Remove the wire and pass it through the upper hole of the mounting plate and connect to the terminal screws on the rear of the wall inlet (Figure 11).
7. Angle the mounting plate and elbow into the previously cut hole in the wall and make the connection with the tubing (Figure 20).
000000 Rev A. 3-05
Figure 21
www.airkinglimited.com
Screw
Holes Figure 22
2. Hang power unit on bracket so that it is properly seated between the two brackets of the power unit and tighten cross bolt (Figure 21).
3. Make tubing connections by cementing intake tubing (from the inlets) to the intake valve and connecting exhaust tubing to the exhaust valve. An optional model AKCVM1 sound muffler (not included) can be installed to the exhaust tubing to reduce the sound of the exhaust air (Figure 22).
NOTE: Exhaust should not be vented into a wall, ceiling, or concealed space within the home. It is best to exhaust to the outdoors.
4 of 16
Wiring
1. Make connections to low voltage wire from inlet to inlet in parallel. Connect any low voltage wire along trunk and branch lines using suitable wire connectors. Connect the low voltage wire to crimp connectors located on the top outside of the power unit (Figure 23).
Low Voltage
Wire
Low Voltage
Wire
2. Your unit is equipped with a self cleaning filter and it should not be removed.
If an excess of debris has built up on the filter you can simply shake it off.
It is recommended that you place a large plastic garbage bag under the unit when doing this.
CAUTION: DO NOT USE GASOLINE, BENZINE, THINNER, HARSH
CLEANSERS, ETC., AS THEY MAY DAMAGE THE RANGE HOOD. NEVER
USE ALCOHOL OR SOLVENTS.
3. If the power unit needs to be cleaned, use a damp towel with a mild detergent, such as dishwashing liquid, and dry with a soft cloth. NEVER USE ANY
ABRASIVE PADS OR SCOURING POWDERS. Use caution when cleaning around motor area and DO NOT allow water to enter into motor chamber.
Completely dry the unit before connecting to power source. NEVER IMMERSE
ELECTRICAL PARTS IN WATER.
Crimp
Connector
Power Unit Lead
To Other
Inlets
Figure 23
Check the System
1. Make sure all inlets are closed and the collection canister is in place. Switch the power on using the manual power switch on the power unit to test.
2. Test the inlets by inserting the power hose. The power unit should turn on and begin suctioning. Check for any air leaks in the system.
Maintenance
CAUTION:
MAKE SURE POWER UNIT IS UNPLUGGED BEFORE
SERVICING THE UNIT.
Inlets
2. Plug the power unit’s grounded cord into a 120 volt grounded receptacle.
LIMITED WARRANTY
All products manufactured by Air King Limited are warranted for one year from the date of purchase against defects in workmanship and/or material. In addition, all ventilating/exhaust fans, heaters, combination fan lights and/or heaters, and range hoods are guaranteed for five years from the date of purchase against defects in workmanship and/or material.
This warranty does not cover any labor or shipping costs or the cost of replacement components as part of routine maintenance such as: range hood grease filters, charcoal filters or combination charcoal/grease filters; replacement light bulbs in range hoods or bathroom fan/light/bulb heater combinations. As well, any damage or failure caused by abuse, misuse, abnormal usage, faulty installation, or improper maintenance will not be covered by this warranty.
In order to make a claim on this warranty, you must be the original consumer of the product. You will be required to present to Air King the original bill of sale showing: date of purchase, place of purchase and model purchased. Failure to meet these requirements will void your warranty.
Air King will not be held responsible for any bodily injury or damages to personal property or real estate whether caused directly or indirectly by the product.
Some states and provinces do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so these exclusions or limitations may not apply to you. This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.
1. The only regular maintenance your system will need is for the collection canister to be emptied. Usage will dictate how often this needs to be done.
To empty the canister, release the two clips on either side of the canister and slide off. When reinstalling, make sure the canister is properly seated in the rubber gasket.
Trouble
1. Unit will not turn on
2. Loss of suction power
Troubleshooting Guide
Probable Cause
1. Power unit is not plugged in.
2. Fuse or circuit breaker blown or OFF.
3. Loose connection in wiring to inlets.
Suggested Remedy
1. Plug power unit in.
2. Check main and branch fuse or circuit breaker.
3. Check wire connections to the inlet to insure proper connection.
1. Collection canister is full.
2. Collection canister not properly installed.
3. Blockage in the hose.
4. Blockage in the pipe.
1. Check to see if collection canister needs to be emptied.
2. Check to make sure canister is properly seated in rubber gasket.
3. Use a long blunt object to clear the blockage
4. Check at inlet location for any obstructions. If the blockage is further into the system, contact your local dealer for assistance.
FOR PARTS OR TECHNICAL ASSISTANCE
Please call: 1-800-465-7300, MONDAY THROUGH FRIDAY, BETWEEN THE HOURS OF 8 AM AND 4:00 PM EST.
PLEASE DO NOT RETURN PRODUCT TO PLACE OF PURCHASE.
Reference the type and style of product (located on label on product) when you call.
For more information please visit our website: wwwairkinglimited.com
000000 Rev A. 3-05 www.airkinglimited.com
5 of 16
advertisement
Key Features
- Powerful suction
- Whole-home cleaning coverage
- Easy canister emptying
- Multiple inlet valve options
- Safety features