RDF

INSTALLATION INSTRUCTIONS

INSTALLATION

OPERATION

MAINTENANCE

09/08

READ AND SAVE THESE INSTRUCTIONS

For The Following Base Models:

RDF 8-8IP, RDF 8-8MAX, RDF 12-8IP, RDF 12-8

( See supplemental instructions for derived models, with duct adapters, manifolds, etc., as appropriate for your particular model.)

CAUTION

For General Ventilating Use Only. Do

Not Use to Exhaust Hazardous or

Explosive Materials and Vapors.

WARNING

TO REDUCE THE RISK OF FIRE,

ELECTRIC SHOCK, OR INJURY

TO PERSONS, OBSERVE THE

FOLLOWING:

This model of centrifugal fan is designed for multiple purposes. It may be used as an in-line rectangular duct fan (Model

RDF) or a manifolded, multi-port fan for multiple exhaust or supply points. It may be installed in a remote location such as an attic space, mechanical room or above a drop ceiling, in a closet or laundry room, to provide quiet exhaust of stale, humid, or otherwise polluted air from bathrooms, the kitchen, laundry, or storage rooms, via exhaust grilles and ducting to the centrally located fan, which is ducted to the outdoors. With small return grilles in bedrooms and other areas, and one duct connection to the outdoors, as the BVS models, it may also be used as a supply ventilator or recirculating central ventilator for the introduction of outdoor air, raising the temperature of the fresh air by mixing with recirculated indoor air.

When used with adjustable balancing grilles or ALDES CAR, Constant Airfl ow

Regulators, and compatible roof/wall caps, ducting, etc., the fan is the heart of a complete pre-engineered ventilation system.

A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally.

When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag to the service panel.

In addition to the following manufacturer’s instructions, it is necessary to comply with federal, state, and local government codes. Your purchase of this American

ALDES ventilation system represents an investment in the health and comfort of the occupants, as well as an investment in the protection of the building from the damaging effects of excessive indoor humidity.

SYSTEM DESIGN:

Satisfactory performance of a central ventilation system requires the proper integration of all the components:

Fan selection for airfl ow, pressure and acoustic properties, vibration characteristics and mounting method, and mode of operation (continuous, manually or automatically controlled)

Proper duct design for friction losses, with compatible supply or exhaust grilles (airfl ow and acoustic properties of the supply/exhaust grilles, and compatible wall/roof caps

Method of balancing airfl ows of multi-point ventilation systems

Consideration for the potential of condensation in the ducting or fan housing (installation in an unheated space)

Upon receipt, inspect the carton to insure the fan has not been damaged in transit.

If damaged, it is the responsibility of the recipient to fi le a damage claim with the carrier. American ALDES Ventilation

Corporation is not responsible for damage incurred during shipment.

Handle the unit with care to prevent damage to the housing and other components. Store the unit indoors if possible. If outdoor storage is required, protection against moisture and dirt is necessary.

Unpack the unit, taking care to look for any loose components among the packing material. Make certain that the fan housing and the blower is free of any loose packing material or small parts.

If not removed before startup, damage and injury may result from solid objects discharged by the blower. Inspect for damage, loose or missing parts.

Install the unit in its fi nal location. The fan may be installed in a mechanical room, crawl space or attic. It is designed to be placed on a fl at surface, against a wall or trusses, or suspended from above. If set on a fl at surface, vibration isolation pads are recommended.

Mounting brackets with rubber grommets are supplied to permit installation against a vertical surface or from a ceiling above.

Alternatively, it may be suspended using threaded rods or chains. At least 12 inches clearance is needed from the access panel to permit servicing the motor.

MOUNTING INSTRUCTIONS

(Differences in bracket type and confi guration may exist on some derived models. Refer to supplement where appropriate). Orient the fan so that the access door can be opened for service.

Tools Required:

Power screwdriver with

No. 2 Philips bit.

Mounting brackets are supplied with the fan. The brackets may be mounted to the fan using the self-drilling screws and rubber grommets provided, at the locations indicated by dimple marks on the side and bottom panels of the fan. Pan head number 10 screws are provided to attach the mounting bracket to the building framing members. It may be necessary to add additional framing members to span wall studs. It is not recommended to use drywall anchors to support the fan. If installed against a concrete or masonry wall, concrete

The fan may also be mounted on a foam rubber pad on a fl at surface, such as an attic fl oor.

FANS MAY BE MOUNTED VERTICALLY OR HORIZONTALLY anchors are recommended. The rubber grommets provide vibration isolation.

The brackets should be attached to the fan fi rst. Then install the wood screws at the keyhole locations and install the fan.

of condensation forming in the fan housing or ducting components. A backdraft damper installed at each grille is very effective in reducing the potential for condensation when the fan is cycled on and off. Insulated ducting must be used where exposed to cold attic or crawl space temperatures, to avoid condensation in the ducting.

Condensation can also be avoided by continuous operation of the fan.

COLD CLIMATE PRECAUTIONS

If installed in an unheated space, in cold climates, there is a possibility

DUCT CONNECTIONS

Ducting may be fl exible or rigid, depending on local codes. If permitted by code, insulated fl exible ducting is recommended for at least several feet on each duct connection, to limit fan noise at the outlet grilles. Ducting should conform to NFPA 90A and meet the requirements of Underwriters Laboratory as a Class O or Class 1 duct to specifi cation UL 181,

Standard for Factory-Made Air Ducts and

Duct Connectors. Metal ducting must be sealed on both the end joints and longitudinal seams to avoid duct leakage and assure proper airfl ows at the grilles.

MAINTENANCE

Monthly:

Inspect and clean the exhaust grilles and fi lters, if so equipped.

Annually:

To ensure the maximum effi ciency of the fan unit, is recommended to clean the inside of the fan box as well as the blower wheel.

CAUTION:

Automatically operated device—to reduce risk of injury disconnect from the power supply before servicing.

DISASSEMBLY

Turn off all power to the unit. The blower

WARNING

TO REDUCE THE RISK OF

FIRE, ELECTRIC SHOCK,

OR INJURY TO PERSONS,

OBSERVE THE

FOLLOWING:

E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault

Circuit Interrupter) - protected branch circuit.

F. NEVER place a switch where it can be reached from a tub or shower.

A. Installation Work and Electrical

Wiring Must Be Done By Qualifi ed

Person(s) In Accordance With All

Applicable Codes And Standards,

Including Fire-Rated Construction.

B. Suffi cient air is needed for proper combustion and exhausting of gases through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire

Protection Association (NFPA), and the American Society for Heating,

Refrigeration and Air Conditioning

Engineers (ASHRAE), and the local code authorities.

C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.

ELECTRICAL

Provide disconnect switch in vicinity of fan, to permit servicing fan, in accordance with NEC and local codes.

Depending on the desired mode of operation, switches may be simple on-off switches, motor speed controls, timer switches, time delay, time of day cycle timers, dehumidistats, occupancy sensing controls, controllers, etc., provided they are rated for motor duty and meet the nameplate electrical ratings of the motor. (Additional application wiring diagrams are available illustrating a variety of controls for use with RDF fans by calling the factory at 1-800-255-7749.)

Base Model

RDF 8-8IP

RDF 8-8MAX

RDF 12-8IP

RDF 12-8

Field Wiring

ELECTRICAL DATA

Volts

115

115

115

115

Max Amps Max Watts

0.19

0.29

0.34

0.53

21

34

41

59

Factory Wiring

Green/Yellow

Black

White

Black

Brown

Field Wiring

Ground

Neutral

115 V

RPM

2500

3135

2200

2960

Factory Wiring for

IP Protected Motors

Green/Yellow

White

White Brown

Black

D. When used as exhaust fans, ducted fans must always be vented to the outdoors.

RDF 8MAX and RDF 12-8

RDF 8-8 IP and

RDF 12-8 IP

For installations in which the fan is connected to a range hood, or if an exhaust grille connected to the fan is located near the cooking surface as shown below, be sure to observe the following safety warnings:

WARNING

TO REDUCE THE RISK OF FIRE, USE ONLY

GALVANIZED STEEL DUCTWORK WHERE

REQUIRED TO USE METAL DUCT.

WARNING

TO REDUCE THE RISK OF A RANGE TOP

GREASE FIRE:

A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.

B. Always turn hood ON when cooking at high heat or fl ambeing food (i.e. Crepe

Suzette, Cherries Jubilee, Peppercorn

Beef Flambe).

C. Clean ventilating fans frequently.

Grease should not be allowed to accumulate on fan or fi lter.

D. Use proper pan size. Always use cookware appropriate for the size of the surface element.

(Note: If the fan is not connected to a range hood or a grille in the vicinity of the cooking surface, other approved ducting may be used as described in "Ducting" section of basic instructions.)

WARNING

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGE TOP

GREASE FIRE, OBSERVE THE FOLLOWING:

A. SMOTHER FLAMES with a close-fi tting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the fl ames do not go out immediately

EVACUATE AND CALL THE FIRE DEPARTMENT.

B. NEVER PICK UP A FLAMING PAN - You may be burned.

C. DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion could result.

D. Use an extinguisher ONLY if:

1. You know you have a Class ABC extinguisher, and you already know how fi re is small and contained in the area where it started.

fi re department is being called.

You a Based on "Kitchen Firesafety Tips" published by NFPA.

may be inspected and cleaned by removing the two screws from the hinged access panel. The blower assembly can now be swung open for cleaning the wheel.

DISCLAIMER:

IT IS THE RESPONSIBILITY

OF THE CONTRACTOR/

INSTALLER TO DETERMINE

THE SUITABILITY OF THIS

EQUIPMENT WITH RESPECT

TO THE POTENTIAL FOR

BACK DRAFTING NATURALLY

VENTED FLUE DEVICES

AND/OR AFFECTING RADON

ENTRY.

BACKDRAFTING AND VENTILATION EQUIPMENT

even though often at lower fl ow rates, the potential for backdrafting the fl ue of these appliances does exist, and represents a dangerous situation.

The International Fuel Gas Code,

Appendix D,- (http://www2.iccsafe.org/ states/Seattle/seattle_fuelgas/PDFs_ fuelgas/Appendix%20D.pdf) provides a Recommended Procedure for Safety

Inspection of an Existing Appliance

Installation.

IMPACT OF EXHAUST FANS:

In especially tight homes heated with naturally vented appliances, such as gas, oil or wood-fi red furnaces, boilers, stoves or fi replaces, the exhaust system may produce suffi cient negative pressure indoors to induce the backdrafting of fl ue gases. This is a common, though intermittent occurrence, with conventional exhaust systems, such as vented kitchen range hoods, clothes dryers, bath fans, etc. In the case of continuous exhaust,

This procedure should be followed to determine the presence of adequate combustion air, while all exhaust fans are operating at maximum speed, and all doors and windows are closed.

In the event that backdrafting occurs, steps must be taken to provide suffi cient combustion air to the furnace or boiler, following the guidelines of the National

Fuel Gas Code and all state and local codes.

MECHANICAL SUPPLY FANS:

Mechanical supply of outdoor air tends to reduce the potential and frequency of backdraft by reducing the contributing negative pressures. However, because of a multitude of factors, including the wide range of exhausting appliances that may be present, effects of wind and building shape, presence of multiple chimneys, building leakage and use of operable windows, no one can assure elimination of backdraft conditions so long as atmospherically vented combustion equipment is present in the home.

American ALDES Ventilation Corporation accepts no liability for backdraft conditions resulting from negative pressures. Nor does American ALDES make representation that blending supply ventilators are adequate to prevent such occurrences.

SEE THE

THREE (3) YEAR WARRANTY

INFORMATION EXPLAINED ON THE

BACK PAGE.

NOTE:

THIS WARRANTY SUPERSEDES ALL

PRIOR WARRANTIES

REPLACEMENT PARTS LIST (BASE MODELS)

Model

Motor

Part No

Impeller

Dimensions

(mm)

Capacitor

Part No. Cap

RDF 8-8IP*

RDF 8-8 MAX

RDF 12-8IP*

86 561

86 561

86 562

133 x 42

133 x 45

180 x 35

86 172

86 172

86 174

4uF

4uF

10uF

RDF 12-8 86 562 180 x 35 86 170 5uF

*Designates Impedance Protection, with alternate wiring of capacitor across aux. winding of motor.

THREE (3) YEAR WARRANTY

THIS WARRANTY SUPERSEDES ALL PRIOR WARRANTIES

FOR FACTORY RETURN YOU MUST:

1) Have a Return Materials

Authorization (RMA) number. This number may be obtained by calling:

AMERICAN ALDES

VENTILATION CORPORATION

PHONE: 1-800 255-7749.

Please have the Bill of Sale available.

2) The RMA number must be clearly displayed on the outside of the carton, or delivery will be refused.

3) All product being returned must be shipped prepaid and be accompanied with a copy of the Bill of Sale.

4) Product will be replaced/repaired and shipped back to buyer. No credits will be issued.

DURING THE FIRST THIRTY (30)

DAYS:

AMERICAN ALDES VENTILATION

CORPORATION will replace any product which has a factory defect in workmanship or material. Product may be returned to either the point of purchase or the AMERICAN ALDES factory, together with Bill of Sale, for an immediate replacement.

DURING THE FIRST THREE (3) YEARS

(excluding the above 30 day period):

AMERICAN ALDES VENTILATION

CORPORATION will replace any product which has a factory defect in workmanship or material. Product must be returned to the AMERICAN ALDES factory, together with the Bill of Sale , and identifi ed with an RMA number.

WARRANTY DOES NOT APPLY TO

THE FOLLOWING:

• Damages from shipping, either

• concealed or visible. Claim must be fi led with the carrier.

Damages resulting from improper wiring or installation.

Damages caused by acts of nature, or resulting from improper consumer

-

-

-

Misuse, abuse, abnormal use, or accident

Incorrect electrical voltage or current

Removal or alterations made on the

AMERICAN ALDES VENTILATION

CORPORATION label control number or date of manufacture

Any other warranty, expressed, written or implied, and to any consequential or incidental damages, loss of property, revenues, or profi t, or costs of removal, installation or reinstallation, for any breach of warranty.

WARRANTY VALIDATION

The end user must keep a copy of the Bill of Sale to verify purchase date.

LIMITATIONS OF

WARRANTY AND LIABILITY

This warranty does not apply to any

AMERICAN ALDES product or part which has failed as a result of faulty installation or abuse, incorrect electrical connections or alterations made by others, or use under abnormal operating conditions or misapplication of the product or parts.

We will not approve for payment any repair not made by us or our authorized agent without prior written consent.

The foregoing shall constitute our sole and exclusive warranty and our sole and exclusive liability, and is in lieu of any other warranties, whether written, oral, implied or statutory. There are no warranties which extend beyond the description on the page hereof. In no event, whether as a result of breach of contract, or warranty or alleged negligence, defect, incorrect advice or other causes, shall AMERICAN ALDES be liable for special or consequential damages, including but not limited to, loss of profi ts or revenue, loss of use of equipment or any other associated equipment, cost of substitute equipment, facilities or services, downtime costs, or claims of customers of purchases for such damages. AMERICAN ALDES neither assumes or authorizes any person to assume for it any other liability in connection with the sale of its products or parts. Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations and exclusions may not apply to you.

BRADENTON, FL 34203

P: 941.351.3441

F: 941.351.3442

E: [email protected]

www.americanaldes.com

09/08

MODEL MPVS 100 AND 120

INSTALLATION INSTRUCTIONS

(Supplement to RDF 09/08)

General: MPVS Series multi-port ventilators are highly versatile continuous duty rated fan units for residential and light commercial applications, and meet

ENERGY STAR effi ciency criteria for low energy consumption. The most popular use is central continuous exhaust ventilation of bathrooms, kitchens, laundry rooms, and other rooms where humidity is a controlling factor, since the fan has a single exhaust discharge duct directly to the outdoors.

DROP DOWN

HINGED

ACCESS

PANEL FOR

SERVICE AND

INSPECTION

The principle advantage of the MPVS central exhaust system is the assurance of controlled indoor air quality ventilation and the elimination of standard noisy bath fans, with the obvious benefi ts of reduced penetrations to the exterior of the building.

With the increased tightness of construction for energy effi cient buildings, there is a growing need of mechanical ventilation for indoor air quality. These fans are designed to serve this purpose as well, by providing effective bathroom ventilation, with the ability to run intermittently or continuously as needed. The quiet, energy effi cient permanent split capacitor external rotor motor has permanently sealed bearings that provide many years of maintenancefree performance.

DIMENSIONS:

MPVS 100 and 120

Duct Confi guration(s) 313, 323, and 333

INSTALLATION

OPERATION

MAINTENANCE

02/09

Construction: The MPVS fan is constructed of heavy gauge galvanized steel to prevent corrosion caused by moisture. The cabinet is internally lined with UL rated, acoustic closed-cell foam vapor barrier insulation. This allows installation directly above living spaces, or in unheated plenum spaces without concern for noise or condensation.

Fan and Motor: The fan motor is an energy effi cient permanent split capacitor type, of external rotor design. Totally sealed to protect against moisture and contaminants, it is approved for use to remove steam and moisture in kitchen and bath areas.

The motor incorporates permanently lubricated sealed bearings and automatic reset thermal overload protection. It is designed and certifi ed for continuous duty or intermittent operation.

The fan uses a backward inclined impeller design that minimizes dust from collecting on the blades and affecting airfl ow performance. Each fan is statically and dynamically balanced in the factory to eliminate vibration and ensure quiet

ELECTRICAL AND AIRFLOW PERFORMANCE

Model

Nominal

RPM

MPVS-100 2980

MPVS-120 3135

HP Volts

0.03

120

0.05

120

Watts at

.2" Ps

22

38

CFM vs. Static Pressure*

MAX.

AMPS 0" .2" .4" .6" .8"

0.19

108 88 68 48 25

0.29

143 128 112 95 74

*Certifi ed airfl ow rating at 0.2" w.g. is derated from actual test results per HVI Certifi cation procedure 920 .

operation. The entire motor and fan assembly is mounted on a drop-down hinged access panel for service and inspection, and can be removed from the fan without disassembly of the ducting connections.

MOUNTING BRACKET

LOCATIONS

Controls: The fans can be operated manually, or automatically by a programmable timer or dehumidistat and may also be operated in conjunction with a variable speed control.

Locating and Installing the Fan:

The compact dimensions and versatile mounting options permit installation above drop ceilings, between ceiling joists, or within a small soffi t location. The fan can be installed either horizontally or vertically.

Airflow Balancing: The flow rates are automatically set with preset ALDES Constant Airflow

Regulators.

A passively controlled element in each duct run infl ates or defl ates automatically in response to system pressure to maintain constant airfl ow.

ELECTRICAL DATA

MPVS 100 / 120

120 V, 60 Hz., .19/.29 amp.,

22/38 W Max., 2980 / 3135 RPM

Above ratings are intended for sizing electrical wring only. Actual consumption will be lower.

AIRFLOW

CFM

10

20

30

40**

50**

3" INTAKE DUCT TO FAN

Recommended

Max. Duct Length from

Grille to Fan (ft.)

SMOOTH

TABLE OF AIRFLOWS AND DUCT LENGHTS *

FLEXIBLE

TOTAL

EXHAUST

RATE CFM

60

FAN DISCHARGE DUCT

Assumes low pressure drop vent cap

4" SMOOTH

40 ft

4" FLEXIBLE

20 ft

225 180

75 25 ft 15 ft

65

30

50

25

90

100

18 ft

15 ft

12 ft

9 ft

20 15

120 11 ft 8 ft

10 10

135 8 ft 6 ft

FOR EACH

ELBOW

DEDUCT

3" Diameter

= 3 Feet

*This table should only be used as a general guide. Actual duct length allowances may be longer on some models. Contact the factory for assistance. **CAR Flow Regulators not available over 35 cfm. NOTE: If longer duct runs are required than permitted in the table above, use smooth ducting and/or increase the diameter.

BRADENTON, FL 34203

P: 941.351.3441

F: 941.351.3442

E: [email protected]

www.americanaldes.com

02/09