Fluidwell Book.indb
CONTENTS
2
OIL METERS
P2
WATER METERS
P8
CHEMICAL METERS
P12
MAG METERS
P18
TURBINE METERS
P21
FLOW SWITCHES
P7
INSTRUMENTATION
P23
ACCESSORIES
P25
SYSTEM DESIGN & BUILD P26
SERVICE & CALIBRATION P27
www.bellflowsystems.com
OIL METERS
SUITABILITY GUIDE
LOW VISCOSITY
HIGH VISCOSITY
G - Series
Positive Displacement - Oval Gear
oil, fuel, fat and lubricating liquids
GRAVITY FEED
PUMPED
HAZARDOUS AREAS
PULSE OUTPUT
J
J
J
J
J
J
G-Series positive displacement flow meters utilise the proven oval rotor design and are available in a
comprehensive selection of models and sizes. All meters are precision engineered and manufactured under
strict conditions of quality control, ensuring high accuracy with excellent levels of repeatability.
G-Series flow meters are suitable for a wide variety of applications on diverse liquids such as kerosene
to bunker oil. The oval rotor design ensures that all fluid is precisely measured without the need for flow
conditioning and with minimum pressure loss through the meter, even on changing to highly viscous
products up to 1 million centipoise.
G 05
1/8”
MODEL
G05ASP-1
G05SSP-1
METER BODY MATERIAL
ALUMINIUM
316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
316 STAINLESS STEEL/BRONZE
316 STAINLESS STEEL
NBR (EPDM, VITON, TEFLON OPTIONS)
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (EPDM, TEFLON OPTIONS)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
0.5 to 50 L/Hour
1 to 50 L/Hour
0.5 to 50 L/Hour
1 to 50 L/Hour
ACCURACY - of reading
+/- 1%
+/- 1%
REPEATABILITY
0.03%
0.03%
MAXIMUM VISCOSITY
1000 Centipoise
1000 Centipoise
MAXIMUM OPERATING PRESSURE
75 PSI/5 BAR
150 PSI/10 BAR (55 Bar option)
PULSER TYPE
HALL EFFECT SENSOR
OR REED SWITCH
HALL EFFECT SENSOR
OR REED SWITCH
G05ASP-1H
PULSES PER LITRE
See main data sheet
See main data sheet
BSP
WEIGHT
240g
600g
NPT
MAX. OPERATING TEMPERATURE
80°C/176°F
120°C/248°F
RECOMMENDED
STRAINER SIZE
25 micron
25 micron
G1
1/4”
G1RSP-1H
BSP
NPT
MODEL
G1ASP-1
G1SSP-1
G1SSPH-1(High Pressure)
METER BODY MATERIAL
ALUMINIUM
316 STAINLESS STEEL
316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (Options available)
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (Options available)
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (Options available)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
1 to 100 L/Hour
2 to 100 L/Hour
1 to 100 L/Hour
2 to 100 L/Hour
1 to 100 L/Hour
2 to 100 L/Hour
ACCURACY - of reading
+/- 1%
+/- 1%
+/- 1%
REPEATABILITY
0.03%
0.03%
0.03%
1000 Centipoise
MAXIMUM VISCOSITY
1000 Centipoise
1000 Centipoise
MAXIMUM OPERATING PRESSURE
75 PSI/5 BAR
150 PSI/10 BAR (55 Bar option)
PULSER TYPE
HALL EFFECT SENSOR
OR REED SWITCH
HALL EFFECT SENSOR
OR REED SWITCH
8000 PSI/551 BAR
HALL EFFECT SENSOR
OR REED SWITCH
PULSES PER LITRE
1000
1000
1000
WEIGHT
240g
600g
3.3kg
MAX. OPERATING TEMPERATURE
80°C/176°F
120°C/248°F
120°C/248°F
RECOMMENDED MESH
STRAINER SIZE
200 MESH
200 MESH
200 MESH
( 0800 0277786
3
OIL METERS
G2
1/4”
MODEL
G2RSP-1
G2SSP-1
G2SSPH-1 (High Pressure)
METER BODY MATERIAL
PPS
316 STAINLESS STEEL
316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIALS
SHAFTS
O’RING
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (Options available)
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (Options available)
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (Options available)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
15 to 500 L/Hour
25 to 500 L/Hour
15 to 500 L/Hour
25 to 500 L/Hour
15 to 500 L/Hour
25 to 500 L/Hour
ACCURACY - of reading
+/- 1%
+/- 1%
+/- 1%
REPEATABILITY
0.03%
0.03%
0.03%
MAXIMUM VISCOSITY
1000 Centipoise
1000 Centipoise
1000 Centipoise
MAXIMUM OPERATING
PRESSURE
75 PSI/5 BAR
150 PSI/10 BAR (55 Bar option)
8000 PSI/551 BAR
PULSER TYPE
HALL EFFECT SENSOR
OR REED SWITCH
HALL EFFECT SENSOR
OR REED SWITCH
HALL EFFECT SENSOR
OR REED SWITCH
BSP
PULSES PER LITRE
400
400
400
NPT
WEIGHT
240g
600g
3.3kg
MAX. OPERATING
TEMPERATURE
80°C/176°F
120°C/248°F
120°C/248°F
RECOMMENDED MESH
STRAINER SIZE
200 MESH
200 MESH
200 MESH
G2RSP-1H
* Polyphenylene Sulfide Resins
G2
1/4”
Fuel consumption meter
(dual chamber design)
MODEL
G2ARP2-1
G2ASP2-1
METER BODY MATERIAL
ALUMINIUM
ALUMINIUM
WETTED COMPONENTS:
ROTOR MATERIALS
SHAFTS
O’RING
316 STAINLESS STEEL/BRONZE
316 STAINLESS STEEL
VITON
316 STAINLESS STEEL/BRONZE
316 STAINLESS STEEL
VITON
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
15 to 500
25 to 500
15 to 500
25 to 500
ACCURACY - of reading
+/- 1%
+/- 1%
REPEATABILITY
0.03%
0.03%
MAXIMUM VISCOSITY
1000 Centipoise
1000 Centipoise
MAXIMUM OPERATING PRESSURE
150 PSI/10 BAR
150 PSI/10 BAR
PULSER TYPE
HALL EFFECT SENSOR
OR REED SWITCH
HALL EFFECT SENSOR
OR REED SWITCH
PULSES PER LITRE
400
400
MAX. OPERATING TEMPERATURE
80°C/176°F
120°C/248°F
RECOMMENDED MESH
STRAINER SIZE
200 MESH
200 MESH
* Polyphenylene Sulfide Resins
BSP
NPT
Optional fuel consumption display
(Battery or 12-24VDC)
G2 with C500 Battery
powered rate/totaliser
option fitted.
High Pressure
G1/G2 model (551 Bar)
4
www.bellflowsystems.com
Accessories, batch
controllers and remote
displays from p23.
OIL METERS
G4
1/2”
BSP
NPT
G4ARM-1
MODEL
G4
METER TYPE
METER WITH MECHANICAL DISPLAY
METER BODY MATERIAL
ALUMINIUM or 316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
*PPS or 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
1 to 30 L/min
3 to 25 L/min
ACCURACY - of reading
+/- 1%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
1000 Centipoise (high viscosity version available)
MAXIMUM OPERATING PRESSURE
34 Bar/500 PSI
MAX. OPERATING TEMPERATURE
80°C/176°F (option 120°C/248°F)
RECOMMENDED MESH STRAINER
60 MESH
* Polyphenylene Sulfide Resins
Options - see GEMINI brochure for full range
Blind - pulser version
G 10
LCD Rate/Totaliser
LCD Rate/Totaliser/Batcher
1”
BSP
NPT
ANSI FLANGED
DIN FLANGED
G10ARM-1
MODEL
G10
METER TYPE
METER WITH MECHANICAL DISPLAY
METER BODY MATERIAL
AA601 ALUMINIUM/316 STAINLESS STEEL/BRONZE
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
*PPS or 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
6 to 120 L/min
10 to 100 L/min
ACCURACY - of reading
+/- 1% / ANALOGUE REGISTER +/- .05%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
(OF STANDARD MODEL)
1000 Centipoise (high viscosity version available)
MAXIMUM OPERATING PRESSURE
500 PSI/34.5 BAR or Flange rule where fitted
MAX. OPERATING TEMPERATURE
80°C/176°F (option 120°C/248°F)
RECOMMENDED MESH STRAINER SIZE
60 MESH
* Polyphenylene Sulfide Resins
Options - see GEMINI brochure for full range
Analogue Register
Blind- pulser version
LCD Rate/Totaliser
LCD Rate/Totaliser/Batcher
( 0800 0277786
5
OIL METERS
G 40
1 1/2”
MODEL
G40
METER TYPE
METER WITH MECHANICAL DISPLAY
METER BODY MATERIAL
ALUMINIUM or 316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
PPS or 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
10 to 250 L/min
15 to 235 L/min
ACCURACY - of reading
+/- 1% / ANALOGUE REGISTER +/- 05%
REPEATABILITY
0.03%
BSP
MAX VISCOSITY
1000 Centipoise (high viscosity version available)
NPT
MAXIMUM OPERATING PRESSURE
260 PSI/18 BAR
Not to be exceeded PED 97/23EC
MAX. OPERATING TEMPERATURE
80°C/176°F, 120°C/248°F
RECOMMENDED MESH STRAINER
60 MESH
ANSI FLANGED
DIN FLANGED
G40ARM-1
* Polyphenylene Sulfide Resins
Options - see GEMINI brochure for full range
Analogue Register
G 50
Blind - pulser version
LCD Rate/Totaliser
2”
BSP
NPT
ANSI FLANGED
DIN FLANGED
G50SSM-1
LCD Rate/Totaliser/Batcher
MODEL
G50
METER TYPE
METER WITH MECHANICAL DISPLAY
METER BODY MATERIAL
AA601 ALUMINIUM or 316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
PPS or 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
15 to 350 L/min
30 to 300 L/min
ACCURACY - of reading
+/- 1% ANALOGUE REGISTER +/- 0.5%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
1000 Centipoise (high viscosity version available)
MAXIMUM OPERATING PRESSURE
260 PSI/18 BAR - Not to be exceeded PED
97/23EC
MAX. OPERATING TEMPERATURE
80°C/176°F (option 120°C/248°F)
RECOMMENDED MESH STRAINER
60 MESH
* Polyphenylene Sulfide Resins
Options - see GEMINI brochure for full range
Analogue Register
6
Blind - pulser version
LCD Rate/Totaliser
LCD Rate/Totaliser/Batcher
www.bellflowsystems.com
OIL METERS
G 80
3”
MODEL
G80
METER TYPE
METER WITH MECHANICAL DISPLAY
METER BODY MATERIAL
AA601 ALUMINIUM
WETTED COMPONENTS:
ROTORS/SHAFTS
BUSHINGS
O’RING
ALUMINIUM/STAINLESS STEEL
BRONZE
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
33 to 733 L/min
66 to 616 L/min
ACCURACY - of reading
+/- 1% or +/- 0.5% (dependant on display option)
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
1000 Centipoise
BSP
MAXIMUM OPERATING PRESSURE
175 PSI/12 BAR - Not to be exceeded PED 97/23EC
NPT
MAX. OPERATING TEMPERATURE
80°C/176°F
RECOMMENDED MESH STRAINER
40 MESH
ANSI FLANGED
DIN FLANGED
G80AAMA-1
* Polyphenylene Sulfide Resins
Options - see GEMINI brochure for full range
Analogue Register
!
Mech-register version
LCD Rate/Totaliser
LCD Rate/Totaliser/Batcher
Accessories, batch
controllers and remote
displays from p23.
Operating Principle
A pair of meshing oval rotors revolve on shafts located within a precision machined chamber inside the
meter body. Close tolerance machining eliminates pockets in which liquid could stagnate and ensures
maximum meter accuracy on thin as well as viscous fluids.
Each rotation measures a swept volume of liquid which is translated into volumetric measurement by
means of a mechanical output shaft or via electronic pulse generation, with options for reed-switch or hall
effect output.
Low pressure drop is a key operating feature of oval rotor flow meters, allowing for use in both pump and
gravity fed applications.
All meters are individually factory tested and their accuracy verified against certified transfer standards.
Calibration reports as well as instruction/installation manuals accompany all meters supplied.
( 0800 0277786
7
OIL METERS
ECONOMICAL FUEL METER
Not certified for fuel resale
diesel, kerosene, petrol, ethanol
SUITABILITY GUIDE
L
J
J
J
J
FUEL RESALE
MD-130 fuel meters are designed for outdoor installation all year round. These meters
are suitable for gravity flow and pumped refuelling systems. Meters are factory
calibrated. Accuracy is +/- 2% and re-calibration may be easily undertaken in the field.
FIELD CALIBRATION
GRAVITY FEED
PUMPED
HAZARDOUS AREAS
MD-130 FUEL METER
FLOW RATE RANGE
12 - 120 Ltrs/min
PORT CONNECTIONS
1” BSP(f) - Alternatively 1 1/2” and 3/4” fittings available
MEASURING PRINCIPLE
NUTATING DISC
PRESSURE
3.4 BAR
HOUSING MATERIAL
ALUMINIUM
STRAINER
INTEGRAL
REGISTER
MAX BATCH 999.9/MAX CUMULATIVE 999,999.9
CALIBRATION
FACTORY CALIBRATED/FIELD ADJUSTABLE
Custody Transfer Approved flow meters are available.
Ask for data sheet.
FLOW SWITCHES
FM Flow Switches / Indicators
For Fluids up to 600 cst viscosity
oil, water, fuel, chemicals
FM flow switches offer a robust and low cost solution to flowrate indication and monitoring.
Rate is displayed on a visual mechanical gauge and switch set-points are field adjustable.
Every flow switch is individually calibrated in any units with single scale to specification.
SUITABILITY GUIDE
LIQUID OR GAS
LOW PRESSURE DROP
ANY ORIENTATION
WIDE VISCOSITY RANGE
HAZARDOUS AREAS
Also
Small Screwed Unit - Aluminium
su
as
for g
FLOW RATE RANGES
PIPE SIZE
MATERIAL OF MANUFACTURE
0
0
0
0
0
0
1/4 - 1”
3/4 - 2”
3”
4”
6”
8”
Aluminium,
Aluminium,
Aluminium,
Aluminium,
Aluminium,
Aluminium,
-
50
400
1000
1500
3000
4500
L/min
L/min
L/min
L/min
L/min
L/min
O’RING SEAL MATERIAL
Bronze,
Bronze,
Bronze,
Bronze,
Bronze,
Bronze,
Cast
Cast
Cast
Cast
Cast
Cast
Iron,
Iron,
Iron,
Iron,
Iron,
Iron,
SS,
SS,
SS,
SS,
SS
SS
PVC
PVC
PVC
PVC
Buna, EPR, Viton, PTFE, Kalrez
PRESSURE (see data sheet)
LP Version = 20 Bar max/HP Version = 140 Bar max
PORT CONNECTIONS
BSP, NPT, BS4504/DIN2632-5, BS1560/ANSI B16.5, BS10
SWITCH OPTIONS
(Field Adjustable)
Standard/Flame Proof/Explosion Proof/Pneumatic
(various configurations ie. single pole - double pole)
OUTPUT OPTIONS
4-20mA
Medium Flanged Unit - Stainless Steel
8
le
itab
J
J
J
J
J
www.bellflowsystems.com
WATER METERS
HYDRAULIC SYSTEMS
SUITABILITY GUIDE
POTABLE WATER
IRRIGATION WATER
HOT WATER
AHS
OTHER LIQUIDS
Water Meters
single-jet, multi-jet, PD, woltmann
PULSE OUPUT
EEC APPROVED
J
J
J
L
J
J
AHS water meters are available in classes B & C of the relevant EEC standards. The range includes a variety
of models based on proven principals which are suitable for industrial and domestic applications. All meters
are designed and tested to provide guaranteed accuracy at extremely competitive prices.
ALFA
single-jet
MODEL
ALFA ~ compact design for most metering applications
METER TYPE
SINGLE-JET IMPELLAR DESIGN
DIAL TYPES AVAILABLE
WET, LIQUID FILLED OR SUPER-DRY DIAL (frost resistant)
METER BODY MATERIAL
BRASS - epoxy coated
WETTED COMPONENTS:
VARIOUS - Drinking water approved (75/33/EEC)
FLOW RATE RANGES
1/2” - 13mm
3/4” - 20mm
1” - 25mm
Qmin 30/25 L/Hour
Qmin 50 L/Hour
Qmin 70 L/Hour
ACCURACY
CLASS B
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
BSP - compression fittings supplied (nuts, tails & washers)
MAXIMUM PRESSURE
16 bar
Qn 1.5/2.5 m3/hr
Qn 2.5 m3/hr
Qn 3.5 m3/hr
Qmax 3 m3/hr
Qmax 7 m3/hr
Qmax 5 m3/hr
MAXIMUM TEMPERATURE
30°C OR 90°C VERSIONS
PULSE OUTPUT OPTION
10 LITRES PER PULSE (1/2” model only) ~ Reed Switch
FILTRATION
INTEGRAL STRAINER (to stop large particles)
SECURITY
TAMPER EVIDENT WIRE LOCK & SEAL
Available with pulse output (see table opposite)
BETA
multi-jet
MODEL
BETA ~ suitable for commercial & general purpose metering
METER TYPE
MULTI-JET IMPELLAR DESIGN
DIAL TYPES AVAILABLE
WET, LIQUID FILLED OR SUPER-DRY DIAL (frost resistant)
METER BODY MATERIAL
BRASS - epoxy coated
WETTED COMPONENTS:
VARIOUS - Drinking water approved (75/33/EEC)
FLOW RATE RANGES
1/2”
- 15mm
3/4”
- 20mm
1”
- 25mm
1 1/4 ” - 30mm
1 1/2” - 40mm
2”
- 50mm
Qmin
Qmin
Qmin
Qmin
Qmin
Qmin
ACCURACY
CLASS B (Class C on request)
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
BSP (nuts, tails & washers supplied) 2” DIN Flanged option
MAXIMUM PRESSURE
10/16 bar
30 L/Hour
50 L/Hour
70 L/Hour
100 L/Hour
200 L/Hour
200 L/Hour
Qn
Qn
Qn
Qn
Qn
Qn
1.5 m3/hr
2.5 m3/hr
3.5 m3/hr
6 m3/hr
10 m3/hr
15 m3/hr
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
3 m3/hr
5 m3/hr
7 m3/hr
12 m3/hr
20 m3/hr
30 m3/hr
MAXIMUM TEMPERATURE 30°C OR 90°C VERSIONS
PULSE OUTPUT OPTION
1, 10, 100, 1000 LITRES PER PULSE ~ Reed Switch
FILTRATION
INTEGRAL STRAINER (to stop large particles)
SECURITY
TAMPER EVIDENT WIRE LOCK & SEAL
Available with pulse output (see table opposite)
( 0800 0277786
9
WATER METERS
HYDRAULIC SYSTEMS
GAMMA
rotary piston
MODEL
GAMMA ~ especially suitable for lower flows and domestic use
METER TYPE
ROTARY PISTON - semi positive displacement
DIAL TYPES AVAILABLE
SUPER-DRY DIAL (frost resistant)
METER BODY MATERIAL
BRASS - epoxy coated
WETTED COMPONENTS:
VARIOUS - Drinking water approved (75/33/EEC)
FLOW RATE RANGES
1/2” - 13mm
3/4” - 20mm
Qmin 15 L/Hour
Qmin 25 L/Hour
ACCURACY
CLASS C
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
BSP - compression fittings supplied (nuts, tails & washers)
MAXIMUM PRESSURE
10/16 bar
Qn 1.5 m3/hr
Qn 2.5 m3/hr
Qmax 3 m3/hr
Qmax 5 m3/hr
MAXIMUM TEMPERATURE
30°C
PULSE OUTPUT OPTION
1, 10, 100, 1000 LITRES PER PULSE ~ Reed Switch
FILTRATION
INTEGRAL STRAINER (to stop large particles)
SECURITY
TAMPER EVIDENT WIRE LOCK & SEAL
MODEL
OMEGA ~ suitable for water distribution and industrial use.
METER TYPE
WOLTMANN - Helix with removable measuring element
DIAL TYPES AVAILABLE
SUPER-DRY DIAL (frost resistant)
Available with pulse output (see table opposite)
OMEGA
woltmann helix
METER BODY MATERIAL
CAST IRON - epoxy coated
WETTED COMPONENTS:
VARIOUS - Drinking water approved (75/33/EEC)
FLOW RATE RANGES
2”
DN50mm
Qmin 450 L/hr
2 1/2” DN65mm
Qmin 750 L/hr
3”
DN80mm
Qmin 1200 L/hr
4”
DN100mm
Qmin 1800 L/hr
6”
DN150mm
Qmin 4500 L/hr
8”
DN200mm
Qmin 7500 L/hr
10”
DN250mm
Qmin 12000 L/hr
12”
DN300mm
Qmin 18000 L/hr
(meters sized up to 20” DN500 available)
Qn
Qn
Qn
Qn
Qn
Qn
Qn
Qn
15 m3/hr
25 m3/hr
40 m3/hr
60 m3/hr
150 m3/hr
250 m3/hr
400 m3/hr
600 m3/hr
ACCURACY
CLASS B
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
DIN Flanged PN16 (others on request)
MAXIMUM PRESSURE
10/16 bar
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
30 m3/hr
50 m3/hr
80 m3/hr
120 m3/hr
300 m3/hr
500 m3/hr
800 m3/hr
1200 m3/hr
MAXIMUM TEMPERATURE 30°C OR 90°C VERSIONS
Available with pulse output (see table opposite)
PULSE OUTPUT OPTION
100, 1000, 10,000 LITRES PER PULSE ~ Reed Switch
FILTRATION
INTEGRAL STRAINER (to stop large particles)
SECURITY
TAMPER EVIDENT WIRE LOCK & SEAL
Definitions:
Normal flow rate Qn
Maximum flow rate
Minimum flow rate
The designated flow rate of the model
Qmax The highest rate at which meter accuracy will be within the maximum permitted error
Qmin The lowest rate at which meter accuracy will be within the maximum permitted error
Transitional flow rate
Qt
The rate at which point the max permitted error of the meter changes
Max permitted error from Qmin to Qt
± 5%
Max permitted error from Qt to Qmax
± 2%
10
www.bellflowsystems.com
WATER METERS
HYDRAULIC SYSTEMS
DELTA
irrigation meter
MODEL
DELTA ~ suitable for sandy/dirty irrigation water
METER TYPE
PADDLE WHEEL - under-shot design
DIAL TYPES AVAILABLE
SUPER-DRY DIAL (frost resistant)
METER BODY MATERIAL
CAST IRON - epoxy coated
WETTED COMPONENTS:
VARIOUS - Drinking water approved (75/33/EEC)
FLOW RATE RANGES
2”
DN50mm
2 1/2” DN65mm
3”
DN80mm
4”
DN100mm
5”
DN100mm
6”
DN150mm
8”
DN200mm
10”
DN250mm
12”
DN300mm
Qmin
Qmin
Qmin
Qmin
Qmin
Qmin
Qmin
Qmin
Qmin
ACCURACY-
CLASS A
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
DIN Flanged PN16
MAXIMUM PRESSURE
16 bar
2.8 L/hr
4 L/hr
6 L/hr
10 L/hr
14 L/hr
20 L/hr
36 L/hr
48 L/hr
64 L/hr
Qn
Qn
Qn
Qn
Qn
Qn
Qn
Qn
Qn
35 m3/hr
50 m3/hr
75 m3/hr
125 m3/hr
175 m3/hr
250 m3/hr
450 m3/hr
600 m3/hr
800 m3/hr
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
Qmax
70 m3/hr
100 m3/hr
150 m3/hr
250 m3/hr
350 m3/hr
500 m3/hr
900 m3/hr
1200 m3/hr
1600 m3/hr
MAXIMUM TEMPERATURE 30°C
PULSE OUTPUT OPTION
ON REQUEST ~ Reed Switch
FILTRATION
A COARSE STRAINER IS REQUIRED UP STREAM
SECURITY
TAMPER EVIDENT WIRE LOCK & SEAL
MODEL
LAMBDA ~ suitable for mobile or in-situ batch control
METER TYPE
TURBINE - With integral laminar flow element
DIAL TYPES AVAILABLE
WET DIAL
Available with pulse output (see table opposite)
LAMBDA
batch control
METER BODY MATERIAL
BRASS - epoxy coated
WETTED COMPONENTS:
VARIOUS - Drinking water approved (75/33/EEC)
FLOW RATE RANGES
1 1/2” DN40mm
2”
DN55mm
Qt 3 m3/hr
Qt 5.5 m3/hr
ACCURACY
CLASS A
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
BSP (nuts, tails & washers supplied)
MAXIMUM PRESSURE
10/16 bar
Qmax 20 m3/hr
Qmax 30 m3/hr
max daily del 200m3
max daily del 300m3
MAXIMUM TEMPERATURE 60°C
DIAL RANGES AVAILABLE 100, 200, 500, 1000, 2000, 5000 LITRES
FILTRATION
A COARSE STRAINER IS REQUIRED UP STREAM
FUNCTION:
LAMBDA-M
LAMBDA-SA
Manual batch progress indication + re-set lever
Automatic output (contact closure) upon batch completion
For suitable solenoid valves see page 26
Low-cost remote totalisers available.
IP67 rated, 7 year battery life
Accessories, batch
controllers and remote
displays from p23.
( 0800 0277786
11
WATER METERS
01N
Digital Water Meter
MODEL
01N
METER TYPE
FLOW TURBINE
DISPLAY
LIQUID CRYSTAL (Total & Cumulative Total to 9,999)
METER BODY MATERIAL
NYLON
WETTED COMPONENTS
VARIOUS
FLOW RATE RANGES
1”
10 - 100 Ltrs/min
ACCURACY
+/- 2% of reading
INSTALLATION
ANY (in straight pipe run as specified in instructions)
CONNECTIONS
1” BSP female
MAXIMUM PRESSURE
10.3 bar/150 PSI
MAXIMUM TEMPERATURE 54° C
POWER
2x AAA Batteries (9000 hrs life)
Available with pulse output
RADIO COMMS + DATA LOGGING + GSM
A selection of single or multi-channel licence exempt radio transmitters and receivers
are available, with options for basic flow totalisation or continuous logging.
These may be suitable where flow meters are sited in difficult to access locations with
or without power, or up to several miles away from the reading point. GSM “dial-in”
capability further enhances remote monitoring and data download possibilities. Call to
discuss your application.
RDLX
remote data logging
MODEL
RDLX - (XR Software included)
INPUTS
Pulse, 4-20mA, mV, AC current etc.
MEMORY
21,000 readings at 12 bit resolution
LOGGING MODES
Single Point or Average
LOGGING RATE
200 Hz to 12 Hours (Programmable)
DATA RETENTION
Over 200 years without power
OPERATING RANGE
-40°C to +60°C
BATTERY LIFE
2-3 Years - GSM option requires 5-30V DC to power modem
See below.
DATA FORMAT
Graphic and CSV, Suitable for export to Excel
GSM OPTION
900/1800 dual wave band - Vodaphone/Cellnet
9600 baud (12 mins for full memory download)
24 A/H alkaline 6V or 12V gel cell
-60 Days continuous standby or 2 yrs at 1 hour standby per day
(Solar/Wind power options are available)
Example GSM logging kit in IP68 weather-proof case shown.
Further kits with a variety of features available.
12
www.bellflowsystems.com
CHEMICAL METERS
SUITABILITY GUIDE
VARIABLE VISCOSITY
G - Series
GRAVITY FEED
PUMPED
Positive Displacement - Oval Gear
solvents, pesticides, resins, glue
HAZARDOUS AREAS
VARIOUS MATERIALS
J
J
J
J
J
G-Series positive displacement flow meters utilise the proven oval rotor design and are available in a
comprehensive selection of models and sizes. The oval rotor design ensures that all fluid is precisely
measured without the need for flow conditioning and with minimum pressure loss through the meter,
even on high and changing viscosity products.
G 05
1/8”
G05ASP-1H
MODEL
G05ASP-1
G05SSP-1
METER BODY MATERIAL
ALUMINIUM
316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
316 STAINLESS STEEL/BRONZE
316 STAINLESS STEEL
NBR (EPDM, VITON, TEFLON OPTIONS)
316 STAINLESS STEEL/SAPPHIRE
316 STAINLESS STEEL
VITON (EPDM, TEFLON OPTIONS)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
0.5 to 50 L/Hour
1 to 50 L/Hour
0.5 to 50 L/Hour
1 to 50 L/Hour
MAXIMUM OPERATING PRESSURE 75 PSI/5 BAR
150 PSI/10 BAR (55 Bar option)
PULSES PER LITRE
See main data sheet
See main data sheet
MAX. OPERATING TEMPERATURE
80°C/176°F
120°C/248°F
RECOMMENDED
25 microns
25 microns
With C500 Battery
powered rate/totaliser
option fitted.
STRAINER SIZE
G1
1/4”
MODEL
G1RRP-1C
G1SSP-1
G1SSPH-1 (High Pressure)
METER BODY MATERIAL
*PPS
316 STAINLESS STEEL
316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
*PPS
HASTALLOY
VITON (EPDM, BUNA, TEFLON)
316 STAINLESS STEEL/SAPHIRE
316 STAINLESS STEEL
VITON (EPDM, BUNA, TEFLON)
316 STAINLESS STEEL/SAPHIRE
316 STAINLESS STEEL
VITON (EPDM, BUNA, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
1 to 100 L/Hour
2 to 100 L/Hour
1 to 100 L/Hour
2 to 100 L/Hour
1 to 100 L/Hour
2 to 100 L/Hour
MAX OPERATING PRESSURE
75 PSI/5 BAR
150 PSI/10 BAR (55 Bar option)
PULSES PER LITRE
1000
1000
1000
120°C/248°F
120°C/248°F
MAX. OPERATING TEMPERATURE 80°C/176°F
8000 PSI/551 BAR
G1RSP-1H
G2
1/4”
MODEL
G2RRP-1C
G2SSP-1
G2SSPH-1 (High Pressure)
METER BODY MATERIAL
PPS
316 STAINLESS STEEL
316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIALS
SHAFTS
O’RING
*PPS
HASTALLOY
VITON (EPDM, BUNA, TEFLON)
316 STAINLESS STEEL/CARBON
316 STAINLESS STEEL
VITON (EPDM, BUNA, TEFLON)
316 STAINLESS STEEL/CARBON
316 STAINLESS STEEL
VITON (EPDM, BUNA, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
15 to 500 L/Hour
25 to 500 L/Hour
15 to 500 L/Hour
25 to 500 L/Hour
15 to 500 L/Hour
25 to 500 L/Hour
MAX OPERATING PRESSURE
75 PSI/5 BAR
150 PSI/10 BAR (55 Bar option)
8000 PSI/551 BAR
PULSES PER LITRE
400
400 (high resolution options- call)
400
120°C/248°F
120°C/248°F
MAX. OPERATING TEMPERATURE 80°C/176°F
G2RSP-1H
BSP
NPT
MODEL
ALL ABOVE
ALL ABOVE
ALL ABOVE
ACCURACY - of reading
+/- 1%
+/- 1%
+/- 1%
REPEATABILITY
0.03%
0.03%
0.03%
PULSER TYPE
HALL EFFECT SENSOR
OR REED SWITCH
HALL EFFECT SENSOR
OR REED SWITCH
HALL EFFECT SENSOR
OR REED SWITCH
RECOMMENDED MESH SIZE
200 MESH (SEE G05)
200 MESH (SEE G05)
* Polyphenylene Sulfide Resins
( 0800 0277786
13
CHEMICAL METERS
G4
1/2”
BSP
G4SRP-1
NPT
MODEL
G4
METER TYPE
PULSER METER
112 Pulses/Litre HALL EFFECT or REED SWITCH
METER BODY MATERIAL
ALUMINIUM OR 316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
*PPS OR 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
1 to 30 L/min
3 to 25 L/min
ACCURACY - of reading
+/- 0.5%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
1000 Centipoise (high viscosity version available)
MAXIMUM OPERATING PRESSURE
55 Bar/800 PSI
MAX. OPERATING TEMPERATURE
80°C/176°F (option 120°C/248°F)
RECOMMENDED MESH STRAINER
60 MESH
* Polyphenylene Sulfide Resins
Options - see GEMINI brochure for full range
Alternative 4-20mA PCB
G7
LCD Rate/Totaliser
LCD Rate/Totaliser/Batcher
1”
BSP
G7RRP-1
NPT
Options - see GEMINI brochure for full range
Alternative 4-20mA PCB
LCD Rate/Totaliser
MODEL
G7
METER TYPE
PULSER METER
52/104 Pulses/Litre HALL EFFECT or REED SWITCH
METER BODY MATERIAL
*PPS
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
*PPS
316 STAINLESS STEEL OR HASTALLOY C
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
3 to 80 L/min
8 to 70 L/min
ACCURACY - of reading
+/- 0.5%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
(OF STANDARD MODEL)
1000 Centipoise
MAXIMUM OPERATING PRESSURE
150 PSI/10 BAR
MAX. OPERATING TEMPERATURE
80°C/176°F (option 120°C/248°F)
RECOMMENDED MESH STRAINER
60 MESH
* Polyphenylene Sulfide Resins
LCD Rate/Totaliser/Batcher
Accessories, batch
controllers and remote
displays from p23.
14
www.bellflowsystems.com
CHEMICAL METERS
G 10
1”
BSP
NPT
ANSI FLANGED
DIN FLANGED
G10SSP-1
TRI-CLAMP
MODEL
G10
METER TYPE
PULSER METER
36/72 Pulses/Litre HALL EFFECT or REED SWITCH
METER BODY MATERIAL
ALUMINIUM, BRONZE or 316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
*PPS or 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
6 to 120 L/min
10 to 100 L/min
ACCURACY - of reading
+/- 0.5%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
(OF STANDARD MODEL)
1000 Centipoise (high viscosity version available)
MAXIMUM OPERATING PRESSURE
800 PSI/55 BAR or flange rule where fitted
MAX. OPERATING TEMPERATURE
80°C/176°F (option 120°C / 248°F)
RECOMMENDED MESH STRAINER SIZE
* Polyphenylene Sulfide Resins
60 MESH
Options - see GEMINI brochure for full range
Mechanical Register
G 40
Alternative 4-20mA PCB
LCD Rate/Totaliser
1 1/2”
LCD Rate/Totaliser/Batcher
Plug ‘n’ Play Batch Control System (St/Steel or Bronze)
MODEL
G40
METER TYPE
PULSER METER
52/104 Pulses/Litre HALL EFFECT or REED SWITCH
METER BODY MATERIAL
ALUMINIUM, BRONZE or 316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
PPS or 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally :VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
10 to 250 L/min
15 to 235 L/min
ACCURACY - of reading
+/- 0.5%
BSP
REPEATABILITY
0.03%
NPT
MAX VISCOSITY
1000 Centipoise (high viscosity version available)
MAXIMUM OPERATING PRESSURE
260 PSI/18 BAR
Not to be exceeded PED 97/23EC
MAX. OPERATING TEMPERATURE
80°C/176°F, 120°C/248°F
RECOMMENDED MESH STRAINER
60 MESH
ANSI FLANGED
DIN FLANGED
G40SRP-1
TRI-CLAMP
* Polyphenylene Sulfide Resins
Options - see GEMINI brochure for full range
Mechanical Register
Alternative 4-20mA PCB
LCD Rate/Totaliser
LCD Rate/Totaliser/Batcher
( 0800 0277786
15
CHEMICAL METERS
G 50
2”
BSP
NPT
ANSI FLANGED
G50SSM-3
DIN FLANGED
MODEL
G50
METER TYPE
PULSER METER 6.68/13.36 Pulses/Litre
HALL EFFECT or REED SWITCH
METER BODY MATERIAL
ALUMINIUM, BRONZE or 316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR MATERIAL
SHAFTS
O’RING
PPS or 316 STAINLESS STEEL
316 STAINLESS STEEL
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
15 to 350 L/min
30 to 300 L/min
ACCURACY - of reading
+/- 0.5%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
1000 Centipoise (high viscosity version available)
MAXIMUM OPERATING PRESSURE
260 PSI/ 18 BAR Not to be exceeded PED 97/23EC
MAX. OPERATING TEMPERATURE
80°C/176°F (option 120°C/248°F)
RECOMMENDED MESH STRAINER
60 MESH
* Polyphenylene Sulfide Resins
Options- see GEMINI brochure for full range
Mechanical Register
G 80
Alternative 4-20mA PCB
LCD Rate/Totaliser
3”
BSP
LCD Rate/Totaliser/Batcher
MODEL
G80
METER TYPE
PULSER METER 14.5/29 Pulses/Ltr
HALL EFFECT or REED SWITCH
METER BODY MATERIAL
AA601 ALUMINIUM
WETTED COMPONENTS:
ROTOR / SHAFTS
BUSHINGS
O’RING
ALUMINIUM or STAINLESS STEEL
BRONZE
NBR (NITRILE) (optionally: VITON, EPDM, TEFLON)
FLOW RATE RANGES
ABOVE 5 CPS
BELOW 5 CPS
33 to 733 L/min
66 to 616 L/min
ACCURACY - of reading
+/- 0.5%
REPEATABILITY
0.03%
MAXIMUM VISCOSITY
1000 Centipoise
MAXIMUM OPERATING PRESSURE
175 PSI/12 BAR- Not to be exceeded PED 97/23EC
NPT
MAX. OPERATING TEMPERATURE
80°C/176°F
ANSI FLANGED
RECOMMENDED MESH STRAINER
40 MESH
G80AAG-3
DIN FLANGED
* Polyphenylene Sulfide Resins
Options- see GEMINI brochure for full range
Analogue Register
16
Alternative 4-20mA PCB
LCD Rate/Totaliser
LCD Rate/Totaliser/Batcher
www.bellflowsystems.com
CHEMICAL METERS
G - Series
head mounted display options
Standard LC Display
The standard LC Display is available on specific
G4, G7, G10, G40, G50 and G80 series models.
It is also available as an accessory so it can be
used as a remote mounted display for any G
Series meter model supplied without a display
e.g. G1, G2, G10ARP.
FEATURES
• 7 Digit x17mm/0.67” and 11 Digit x8mm/0.31”
Liquid Crystal Display.
• Display can be rotated in 90° steps.
• Flow rate display in litres or US gallons (or
other selectable eng’g units).
• 2 total displays - resettable, up to 999999,9
and non-resettable, up to 9999999999.9
litres or US gallons etc.
• Fully progammable.
• Long life 3.2 volt (7 year) Lithium battery.
• Approved for hazardous locations:
EEx ia IIB/IIC T6 (Kema Ex-00.E.1127x)
• Options for Hi/Low Alarms, 4-20mA Output,
Temperature compensation etc.
Deluxe LC Display
The Deluxe LC Display is available on specific
G4, G7, G10, G40, G50 and G80 series
models. It is also available as an accessory so
it can be used as a remote mounted display
for any G Series meter model supplied without
a display e.g. G1, G2, G10ARP.
FEATURES
• 7 Digit x 12.7mm (1/2”) Liquid Crystal
Display.
• Display can be rotated in 90° steps.
• Selectable flow rate display in litres or US
gallons.
• 2 total displays.
• Up to 999999.9 litres or US gallons
(resettable).
Standard LC Display
• Pre-settable batch control function up to
9999 units (99.99, 999.9 or 9999 optional
settings).
• 10 preset batch quantity storage capacity.
• 3 digit cycle counter for batch dispensed.
• Single or dual valve actuation output to be
used with appropriate trip amplifier.
• Adjustable calibration constant
(K Factor).
• Additional 9 calibration constants
(K Factors) available for “in-the-field”
settings.
• Up to 9999999 litres or US gallons
(non-resettable).
• Transistor output to batch relay.
• Long Life 3-volt Lithium/CR2040 battery.
• Approved for hazardous locations (standard
battery only) EEx ia IIC T6 (PTB nr. Ex-93.C
4033X).
Deluxe LC Display
Mechanical Display - Digital
The Mechanical Display is available
on specific G4, G10, G40 and G50 Series
meter models.
FEATURES
• Litre or US gallon display (according to
model selected).
• Two Totals:
Non Reset
Litre 9,999,990
USG 999,999
Reset
Litre 9,999
USG 999.9
• Push button reset.
• Display can be rotated in 90° steps.
Mechanical Display
( 0800 0277786
17
CHEMICAL METERS
!
Operating Principle
A pair of meshing oval rotors revolve on shafts located within a precision machined chamber inside the
meter body. Close tolerance machining eliminates pockets in which liquid could stagnate and ensures
maximum meter accuracy on thin as well as viscous fluids.
Each rotation measures a swept volume of liquid which is translated into volumetric measurement by
means of a mechanical output shaft or via electronic pulse generation, with options for reed-switch or hall
effect output.
Low pressure drop is a key operating feature of oval rotor flow meters, allowing for use in both pump and
gravity fed applications.
All meters are individually factory tested and their accuracy verified against certified transfer standards.
Calibration reports as well as instruction/installation manuals accompany all meters supplied.
18
www.bellflowsystems.com
MAG METERS
Mag-Series
Electromagnetic Flow meters
chemicals, effluent, process fluids
NO MOVING PARTS
J
NON CONDUCTIVE FLUID
L
FULL BORE FLOW PATH
J
HIGH SOLIDS CONTENT
J
LOW MAINTENANCE
J
HAZARDOUS AREAS
J
Electromagnetic meters provide obstruction free flow measurement of all conductive liquids including:
chemicals, food stuffs, pulps, acids, pharmaceuticals and effluent. Their high accuracy is unaffected by
changes in fluid viscosity, line pressure, temperature or density. They are available with a choice of liners,
outputs, connections and displays.
CHECK-MAG
+ data
MODEL
METER TYPE
CHECK-MAG
ELECTROMAGNETIC
METER BODY MATERIAL
WELDED CARBON STEEL CONSTRUCTION
FLOW TUBE MATERIAL
STAINLESS STEEL
METER LINER MATERIAL
HARD RUBBER / SOFT RUBBER / PTFE
ELECTRODES:
STAINLESS STEEL (others on request)
SIZES
DN10 to DN1000
ACCURACY
0.5% in 10-100% RANGE (TRACEABLE CALIBRATION)
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
WIDE CHOICE OF FLANGES
MAXIMUM PRESSURE
40 BAR (dependant on sensor diameter and flange rule)
MAXIMUM TEMPERATURE HARD RUBBER 90°C / SOFT RUBBER 130°C / PTFE 180°C
OUTPUTS
PULSE, FREQUENCY, RS COMMS, 4-20mA
POWER SUPPLY
10 / 230 VAC
FEATURES
DATA LOGGING OF TOTALS & AVERAGES, BI-DIRECTIONAL,
NON FULL PIPE, SENSOR ELECTRODE CLEANING
MODEL
MAG-900
METER TYPE
ELECTROMAGNETIC (Bi-directional)
Available with remote or integral display unit
MAG-900
budget range
METER BODY MATERIAL
WELDED CARBON STEEL CONSTRUCTION
FLOW TUBE MATERIAL
STAINLESS STEEL
METER LINER MATERIAL
RUBBER / PTFE
ELECTRODES:
STAINLESS STEEL
SIZES
DN10 to DN1000
ACCURACY
0.5% (0.5 - 10m/s) 1% (0.1 - 0.5m/s)
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
CHOICE OF FLANGES
MAXIMUM PRESSURE
PN6, 10, 16, 25
MAXIMUM TEMPERATURE COMPACT 60°C / REMOTE 130°C
OUTPUTS
PULSE, FREQUENCY, INFRA-RED RS232, 4-20mA
POWER SUPPLY
110 / 230 VAC or 24V AC/DC
FEATURES
WINCAL & WINFLOW SOFTWARE SUPPLIED FOR EASY
CONFIGURATION BY PC, VIA CABLE SUPPLIED
Built-in Liquid Crystal display with choice of outputs
( 0800 0277786
19
MAG METERS
BUD-MAG
hygienic
MODEL
BUD-MAG
METER TYPE
ELECTROMAGNETIC
METER BODY MATERIAL
STAINLESS STEEL CONSTRUCTION
FLOW TUBE MATERIAL
STAINLESS STEEL
METER LINER MATERIAL
EXTRUDED WHITE PTFE
ELECTRODES
STAINLESS STEEL
SIZES
DN10 to DN50
ACCURACY
0.5% O.R.
INSTALLATION
HORIZONTAL OR VERTICAL
CONNECTIONS
SANITARY FITTINGS DIN 11851 / FLANGED ANSI 150RF
MAXIMUM PRESSURE
40 BAR (dependant on fittings and temperature)
MAXIMUM TEMPERATURE 180°C (dependant on fittings and pressure)
OUTPUTS
PULSE, FREQUENCY, RS COMMS, 4-20mA
POWER SUPPLY
110 / 230 VAC
FEATURES
DATA LOGGING OF TOTALS & AVERAGES, BI-DIRECTIONAL,
NON FULL PIPE, SENSOR ELECTRODE CLEANING
Available with pulse output (see table opposite)
The full range of Danfoss electromagnetic flow meters are available
from Bell Flow Systems. Danfoss have been a pioneer in the field of
non-intrusive flowmeters technologies since 1970.
Call for a MAGFLO® brochure or for further information.
!
Operating Principle
Electromagnetic flow meters are suitable for all conductive liquids including: aggressive, abrasive and
hygienic fluids.
They are also suitable for applications with high solids content due to their non-intrusive design.
Measurement is achieved via two electrodes mounted in the body of the meter which sense the changes
in a magnetic field caused by the passage of electrically conductive liquids. The measurement of this
electromotive force is based on Faraday’s Law of Electromagnetic
Induction and the resulting signal is conditioned by the integral or
remote mounted converter to give accurate measurement of flow rate.
Accessories, batch
controllers and remote
displays from p23.
20
www.bellflowsystems.com
TURBINE METERS
LFT-Series
LIQUID Turbine Flow meters
water, chemicals, general process
LFT/GFT-Series turbines are highly accurate and
robust flowmeters, yet economically priced.
They are suitable for low viscosity lubricating
and non-lubricating fluids as well as dry gases.
All models are manufactured from stainless
steel, making them suitable for aggressive and
corrosive media, as well as hygienic applications.
Pressure and temperature compensating
displays are available for this range.
LFTbsp
LFTflanged
J
HIGH VISCOSITY
L
LOW PRESSURE DROP
J
HIGH TEMPERATURE
J
HIGH PRESSURE
J
HAZARDOUS AREAS
J
MODEL
LFT
METER TYPE
FLOW TURBINE
METER BODY MATERIAL
316 STAINLESS STEEL
WETTED COMPONENTS:
ROTOR SUPPORTS
JOURNAL BEARINGS
ROTOR BLADE
ROTOR SHAFT
316 STAINLESS STEEL
TUNGSTEN CARBIDE
ANC1A STAINLESS STEEL
TUNGSTEN CARBIDE
LINEARITY
+/- 0.5% (less than +/- 0.2% when used with linearizing display)
INSTALLATION
STRAIGHT SECTION OF PIPE REQUIRED
CONNECTIONS
BSPP/Flanged ANSI 150/300, DIN-PN16, DIN-PN25/TRI-CLAMP
MAXIMUM PRESSURE
SEE BELOW
MAXIMUM TEMPERATURE
120°C (350°C option)
PULSE OUTPUT OPTIONS
AMPLIFIER AVAILABLE/2ND PICK-UP/I.S. CERTIFIED VERSION
FILTRATION
UPSTREAM FILTER RECOMMENDED
FLOW RATE RANGES- BSP Screwed
size
3/8 “
½“
5/8 “
¾“
1“
1½“
2“
connection
½ “ BSP
½ “ BSP
¾ “ BSP
¾ “ BSP
1” BSP
1 ½ “ BSP
2 “ BSP
250 BAR MAX W.P
range ltrs/min
1 - 10
2 - 20
5 - 50
14 - 140
27 - 270
55 - 550
114 - 1140
length
70
70
76
76
88
114
133
FLOW RATE RANGES- FLANGED ANSI 150/300, DIN-PN16, DIN-PN25 MAX W.P = Flange rule
size
¾“
1“
1½“
2“
3“
4“
6“
LFTtri-clamp
LOW VISCOSITY
connection
¾“
1“
1½“
2“
3“
4“
6“
range ltrs/min
14 - 140
27 - 270
55 - 550
114 - 1140
227 - 2270
454 - 4540
908 - 9080
FLOW RATE RANGES- Tri-Clamp
size
¾ “
1“
1½“
2“
( 0800 0277786
connection
1 “ Ferrule
1 ½ “ Ferrule
2 “ Ferrule
2 ½ “ Ferrule
length
140
152
165
165
165
210
240
68 BAR MAX W.P
range ltrs/min
3.5 - 35
7 - 70
14.5 - 145
30 - 300
length
50
64
88
100
21
TURBINE METERS
GFT-Series
GAS Turbine Flow meters
dry gases: inert and flammable
GFTbsp
HIGH ACCURACY
J
LOW PRESSURE DROP
J
SIMPLE DESIGN
J
HIGH PRESSURE
J
SELF POWERED
J
HAZARDOUS AREAS
J
FLOW RATE RANGES - BSP Screwed
size
3/8 “
½“
5/8 “
¾“
1”
1½“
2“
connection
½ “ BSP
½ “ BSP
¾ “ BSP
¾ “ BSP
1 “ BSP
1 ½ “ BSP
2 “ BSP
250 BAR MAX W.P.
range m3/hr
0.3 - 4.2
0.5 - 7
1 - 14
2.5 - 35
5 - 70
10 - 140
18 - 252
length
70
70
76
76
88
114
133
(also available NPT screwed)
GFTflanged
GFTwafer
FLOW RATE RANGES - FLANGED ANSI 150/300, DIN-PN16, DIN-PN25
MAX W.P. = Flange rule
size
¾“
1“
1½“
2“
3“
4“
6“
length
140
152
165
165
165
210
240
connection
¾“
1“
1½“
2“
3”
4“
6“
range m3/hr
2.5 - 35
5 - 70
10 - 140
18 - 252
35 - 490
70 - 980
140 - 1960
FLOW RATE RANGES - WAFER between flanges style
100 BAR MAX W.P.
size
¾“
1“
1½“
2“
3“
length
50
50
64
76
100
connection
43 mm R.F. Dia
52 mm R.F. Dia
73 mm R.F. Dia
92 mm R.F. Dia
127 mm R.F. Dia
range m3/hr
2.5 - 35
5 - 70
10 - 140
18 - 252
35 - 490
!
Operating Principle
Flow turbines provide an inferential measurement of flow. The rotor blades sweep out the full bore of the
meter except for a small tip clearance space. As the blade tips pass the magnetic pick up they initiate a
pulse. Flow rate is determined by the frequency of the pulses and Totalised Flow is obtained by summing
the pulses.
Internals Kit‘s (calibrated) can be supplied, which are very easy to retrofit into an existing body on location
(eliminating the need to return the turbine for calibration) .
FT2 low-cost flowmeter range
PPS body and PVDF turbine.
available with a choice of fittings.
0.01 - 160 L/min (10 models)
(CALL FOR A BROCHURE)
22
www.bellflowsystems.com
Accessories, batch
controllers and remote
displays from p23.
TURBINE METERS
A2
Digital Turbine Flow meters
water, chemicals, general process
LOW VISCOSITY
J
HIGH VISCOSITY
L
LOW PRESSURE DROP
J
HIGH TEMPERATURE
J
HIGH PRESSURE
J
HAZARDOUS AREAS
J
A2 Digital Turbine Flow meters are highly reliable and robust flowmeters, yet economically priced.
They are suitable for low viscosity lubricating and non-lubricating fluids. All models are factory calibrated,
but can be easily field calibrated, for increased accuracy. A choice of materials and fittings makes them
equally suitable for neutral or aggressive and corrosive media, as well as hygienic applications. All models
feature a built-in battery powered rate/totaliser, with the option of pulse output.
A2 Stainless steel
A2 Aluminium
A2 PVDF
A2 PVC
316 STAINLESS STEEL - BSP Screwed (Tri-clamp on request)
Pressure rating 103 Bar
model
S050
S075
S100
S150
S200
connection
½ “ BSP
¾ “ BSP
1 “ BSP
1½” BSP
2” BSP
range (extended)
1.9 - 37.9
3.8 - 75.7
9.5 - 190
19 - 380
38 - 760
ROTOR/SHAFT
PVDF/TUNGSTEN CARBIDE
BEARINGS
CERAMIC (98% ALUMINA)
range (linear)
3.8 - 37.9
7.6 - 75.7
18.9 - 190
38 - 380
76 - 760
ALUMINIUM - BSP Screwed
Pressure rating 20 Bar
model
A050
A075
A100
A150
A200
connection
½ “ BSP
¾ “ BSP
1 “ BSP
1½” BSP
2” BSP
range (linear)
3.8 - 37.9
7.6 - 75.7
18.9 - 190
38 - 380
76 - 760
ROTOR/SHAFT
PVDF/TUNGSTEN CARBIDE
BEARINGS
CERAMIC (98% ALUMINA)
PVC - Solvent Weld or NPT female
Pressure rating 10.2 Bar
model
C050
C100
connection
½ “ BSP
1 “ BSP
ROTOR/SHAFT
PVDF/TUNGSTEN CARBIDE
BEARINGS
CERAMIC (98% ALUMINA)
O-RING
VITON
range (linear)
3.78 - 37.80
18.9 - 190
PVDF - BSP Screwed or NPT
range (extended)
2.27 - 45.36
9.5 - 190
Pressure rating 10.2 Bar
model
C050
C100
connection
½ “ BSP
1 “ BSP
ROTOR/SHAFT
PVDF/TUNGSTEN CARBIDE
BEARINGS
CERAMIC (98% ALUMINA)
O-RING
VITON
( 0800 0277786
range (extended)
1.9 - 37.9
3.8 - 75.7
9.5 - 190
19 - 380
38 - 760
range (linear)
3.78 - 37.80
18.9 - 190
range (extended)
2.27 - 45.36
9.5 - 190
23
INSTRUMENTATION
Fluidwell
EASY TO CONFIGURE
J
Instrumentation family
flow, level, pressure, temperature
RANGE OF ENCLOSURES
J
SELF POWERED RANGE
J
SPECIALS BY REQUEST
J
HAZARDOUS AREAS
J
Fluidwell products are the ideal choice for a wide variety of flowmetering applications, with a
selection of easy to program models and a comprehensive list of options to choose from.
Fluidwell instruments combine ‘state of the art’ electronic engineering with innovative
software design. Couple this with a common user-friendly menu interface across the range
and you have a single source for a wealth of modern industrial measurement and control
instrumentation to meet your every need.
model range
FOSERIES
FIELD MOUNT INDICATOR
The FO-series range has been developed with primary functionality only in mind. Various
models exist for the cost conscious, featuring a variety of basic display, output and alarm
functions.The range is suitable for panel or wall-mounting and features the same user
interface as the F1- and 200-series products for more advanced measurements. Models
approved to Cenelec EEx ia IIB T4 (CSA & FM pending).
F1SERIES
FIELD MOUNT INDICATOR
The F1-series range offers versatility in a unit which can be both panel or remote mounted.
Various models exist to accept pulse or analogue inputs, with a wide selection of features
including: pulse/analogue re-transmission, hi/low alarm functions, signal linearisation,
square root extraction, batch control, RS comms, dual signal input, ratio control and more.
Cenelec EEx ia IIB T4 (CSA & FM pending). EExd enclosure available to EEx d IIB T5.
200SERIES
PANEL MOUNT INDICATOR - (DIN 43700) Large clear IP65 display.
The 200-series range has been designed with a rugged aluminium enclosure and resistant
ABS front panel with sturdy push buttons. Various models exist to accept pulse or analogue
inputs. A wide selection of features and options are available. 200-series units contain an
innovative self-tuning power supply 80-240V AC with the option to connect 12-28V AC/DC.
(EEX ia) approval - pending. Explosion proof enclosure available to EEx d IIB T5.
300SERIES
INDUSTRIAL BATCH CONTROLLERS & LOADING SYSTEMS
The 300-series range incorporates a wide selection of enclosures and feature packed
systems for controlling fluid and gas batching applications. Some of the models available
include: high speed batchers with CIP control, dual channel batch controllers as well as
advanced tanker loading systems and multiple menu-batchers with printer output and
operator ID. Explosion proof enclosure available to EEx d IIB T5.
600SERIES
PANEL MOUNT INDICATOR - (DIN 43700) Large back-lit LCD display
The 600-series range has been designed primarily for applications where simultaneous
flowmeter inputs require mathematical evaluation. Such as: additive addition, ratio control
and ingredient consumption analysis. Features of the range include: mass flow calculation,
curve linearisation, dual analogue output and multiple pulse/relay inputs and outputs.
All totals and process data are stored in NVRAM for safety.
24
www.bellflowsystems.com
INSTRUMENTATION
FO-SERIES
Universal mount
Panel-mount
IP65
FO-SERIES : (budget range) See catalogue for full selection
Model
Description
Input Options
Mounting Options
Power Options
F010-X
Basic Totaliser
(1x reset & 1x non reset)
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F011-X
Basic Rate Indicator
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F012-X
Basic Rate/Totaliser
(1x reset & 1x non reset)
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F013-X
Basic Rate/Totaliser +
(1x high/low alarm output)
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F014-X
Basic Rate/Totaliser +
(1x pulse output)
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F016-P
Basic Rate/Totaliser +
(signal linearisation)
pulse
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F030-P
Basic Batch Controller
(single stage)
pulse
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
GENERAL SPECIFICATIONS
Field-mount
ABS - IP65
DISPLAY
High intensity reflective alphanumeric LCD, UV-resistant
DIGITS
Seven 17mm (0.67”) and eleven 8mm (0.31”) operator selectable symbols and units
OPERATING TEMPERATURE
-30°C to +80°C (-22°F to +178°F) (Lower on I.S. Model see data sheet)
CE
EMC compliant ref: EN50081 and EN50082
HAZARDOUS AREA
Cenelec EEx ia IIB T4 Intrinsically Safe (EExd available)
INPUT OPTIONS
Field-mount
Aluminium
IP67
F1-SERIES
Universal mount
Panel-mount
ABS or Aluminium
IP65 rated
Pulse
coil/sine wave, namur, reed switch, NPN, PNP (Selectable low pass filter fitted)
4-20
(0)4-20mA Span/zero adjustable (Linear & Square root calculation)
0-10
0-10V DC Span/zero adjustable (Linear & Square root calculation)
OUTPUT OPTIONS
Transistor
Volt-free Contact
1x transistor (max 50VDC 300mA)
1x electro-mechanical relay (max 240V AC 0.5A)
F1-SERIES : See catalogue for full range
Model
Description
Input Options
Mounting Options
Power Options
F110-X
Rate/Totaliser 4-20 & Pulse O/P
(1x reset & 1x non reset)
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F112-X
Rate/Totaliser 4-20 & Pulse O/P
15 Point Linearisation
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F113-X
Rate/Totaliser 4-20 & Pulse O/P
2x high/low alarm Outputs
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F116-X
Differential Rate/Totaliser +
4-20 & Pulse O/P
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F120-P
PI (D) Flowrate controller +
4-20 & high/low alarm
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F126-P
Rate/Totaliser 4-20 O/P +
Temp/Pressure correction
pulse/4-20mA/0-10V
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
F130-P
Batch Controller (printout option) pulse/4-20mA/0-10V
2 stage/auto correct/remote start
Panel/Field-mount
Battery/Loop/24VDC/110-230VAC
GENERAL SPECIFICATIONS
Field-mount
ABS
IP65 rated
DISPLAY
High intensity reflective alphanumeric LCD, UV-resistant
DIGITS
Seven 17mm (0.67”) and eleven 8mm (0.31”) operator selectable symbols and units
OPERATING TEMPERATURE
-30°C to +80°C (-22°F to +178°F) (Lower on I.S Model see data sheet)
CE
EMC compliant ref: EN50081 and EN50082
HAZARDOUS AREA
Cenelec EEx ia IIB T4 Intrinsically Safe (EEx d available)
INPUT OPTIONS
Field-mount
Aluminium
IP67 rated
Pulse (0-10KHz)
coil/sine wave, namur, reed switch, NPN, PNP (Selectable low pass filter fitted)
4-20
(0)4-20mA Span/zero adjustable (Linear & Square root calculation)
0-10
0-10V DC Span/zero adjustable (Linear & Square root calculation)
OUTPUT OPTIONS
Transistor
Volt-free Contact
RS Comms
3x transistor (max 50VDC 300mA)
2x electro-mechanical relay (max 240V AC 0.5A)
RS232 or RS485 Modbus (ASCII/RTU) Full read/write capabilities
( 0800 0277786
25
INSTRUMENTATION
200-SERIES
Panel mount
Panel-mount
IP65
200-SERIES : Panel Mount to DIN 43700
Model
Description
Input Options
F210-X
Rate/Totaliser 4-20 & Pulse O/P
pulse/4-20mA/0-10V
Panel-mount
(1x reset & 1x non reset)
Mounting Options
Loop/12-28VDC/80-240VAC
Power Options
F212-X
Rate/Totaliser 4-20 & Pulse O/P
pulse/4-20mA/0-10V
15 Point Linearisation
Panel-mount
Loop/12-28VDC/80-240VAC
F213-X
Rate/Totaliser 4-20 & Pulse O/P
pulse/4-20mA/0-10V
Panel-mount
4x high/low alarm Outputs
Loop/12-28VDC/80-240VAC
F216-X
Differential Rate/Totaliser +
pulse/4-20mA/0-10V
4-20 & Pulse O/P
Panel-mount
Loop/12-28VDC/80-240VAC
F220-P
PI (D) Flowrate controller +
pulse/4-20mA/0-10V
4-20 & high/low alarm
Panel-mount
Loop/12-28VDC/80-240VAC
F225-P
Rate/Totaliser 4-20 O/P +
pulse/4-20mA/0-10V
Panel-mount
Temp/Pressure correction (4-20/PRTD100)
F231-P
Batch Controller (printout option) pulse/4-20mA/0-10V
Panel-mount
2 stage/auto correct/remote start
Loop/12-28VDC/80-240VAC
Loop/12-28VDC/80-240VAC
GENERAL SPECIFICATIONS
DISPLAY
High intensity transflective alphanumeric LCD, UV-resistant. (backlight option)
DIGITS
Seven 17mm (0.67”) and eleven 8mm (0.31”) operator selectable symbols and units
OPERATING TEMPERATURE
-30°C to +80°C (-22°F to +178°F) (Lower on I.S. Model see data sheet)
CE
EMC compliant ref: EN50081 and EN50082
HAZARDOUS AREA
Cenelec EEx ia IIB T4 Intrinsically Safe (EExd version available)
INPUT OPTIONS (Inc 4x Status Inputs)
300-SERIES
Batch controllers
Wall-mount
Polystrol - IP50
Wall-mount
Polystrol - IP65
Pulse
coil/sine wave, namur, reed switch, NPN, PNP (Selectable low pass filter fitted)
4-20
(0)4-20mA Span/zero adjustable (Linear & Square root calculation)
0-10
0-10V DC Span/zero adjustable (Linear & Square root calculation)
OUTPUT OPTIONS
Transistor
Volt-free Contact
4x transistor (max 50VDC 300mA)
4x electro-mechanical relay (max 240V AC 0.5A)
300-SERIES : BATCH CONTROLERS
Model
Description
Input Options
0302-X
Batch Controller - High Speed
NPN/PNP or NAMUR
Panel/Wall-mount
(8x presets/single-dual stage)
24VDC/110-230VAC
0303-X
Batch Controller - Sequential
NPN/PNP or NAMUR
Panel/Wall-mount
(8x presets/single-dual stage)
24VDC/110-230VAC
0310-X
Batch Controller - Basic Model
NPN/PNP or NAMUR
(single-dual stage)
Panel/Wall-mount
24VDC/110-230VAC
0313-X
Batch Controller + Printer output NPN/PNP or NAMUR
(single-dual stage)
Panel/Wall-mount
24VDC/110-230VAC
0320-P
Batch Controller - High Spec
NPN/PNP or NAMUR
Panel/Wall-mount
(4x presets/single-dual stage)
24VDC/110-230VAC
0326-P
Tanker Loading system
NPN/PNP or NAMUR
Panel/Wall-mount
(optional 4-20mA batch valve control)
24VDC/110-230VAC
0330-P
Batch Controller - Dual Channel
NPN/PNP or NAMUR
24VDC/110-230VAC
26
Panel/Wall-mount
Power Options
GENERAL SPECIFICATIONS
DISPLAY
High intensity transflective alphanumeric LCD with backlight
DIGITS
4 lines (20 characters per line) operator selectable symbols and units. (Eng, Fr, Dutch, German)
OPERATING TEMPERATURE
0°C to +55°C (32°F to +131°F)
CE
EMC compliant ref: EN50081 and EN50082.
OVER-RUN CORRECTION
Selectable ON/OFF Auto over-run correction profiles valve performance to enhance batch accuracy
INPUT OPTIONS
Panel-mount
Alu/SS - IP65
Mounting Options
PULSE = NPN/PNP or NAMUR type sensors (0 - 10KHz)
LOGIC INPUTS = 9x Status inputs (function dependant on unit)
OUTPUT OPTIONS
Volt-free Contacts
Solid-State relays
RS Comms
3x electro-mechanical relay (max 230V AC/DC - 1A)
2x transistor (max 48VDC - 1A)
RS232 or RS485 Modbus (ASCII/RTU) Full read/write capabilities
www.bellflowsystems.com
VALVES
ACCESSORIES
Solenoid, Angle Seat, Diaphragm, Motorized
MODULAR DIRECT ACTING SOLENOID - Steam and media at high temperatures up to 180 °C
Port
BSPP
6013 Solenoid Valve
Orifice
mm
Kv-value
(water m3/h)
Pressure Range
(AC)
(DC)
Weight
(g)
Voltage options
1/4”
2.0
0.12
0-16
0-12
360
24V AC/DC 110/230 AC
1/4”
3.0
0.23
0-14
0-8
360
24V AC/DC 110/230 AC
3/8”
3.0
0.23
0-14
0-8
500
24V AC/DC 110/230 AC
BRASS
SERVO-ASSISTED SOLENOID - neutral liquids up to 90°C or St/Steel version slightly aggresive media up to 90°C
BRASS
6213 Solenoid Valve
ST/STEEL
Port
BSPP
Orifice
mm
1/4”
10
Kv-value
(water m3/h)
2.0
Pressure Range
(AC)
(DC)
0-10
Weight
(kg)
0-10
0.40
Voltage options
24V AC/DC 110/230 AC
3/8”
10
2.0
0-10
0-10
0.40
24V AC/DC 110/230 AC
1/2”
13
3.6
0-10
0-10
0.55
24V AC/DC 110/230 AC
3/4”
20
9.0
0-10
0-10
1.0
24V AC/DC 110/230 AC
1”
25
11
0-10
----
1.7
24V AC
110/230 AC
*1 1/4”
25
11
0-10
----
1.7
24V AC
110/230 AC
*1 1/2”
40
30
0-10
----
3.60
24V AC
110/230 AC
*2”
40
30
0-10
----
3.60
24V AC
110/230 AC
* St/Steel up to 1” only
MODULAR DIRECT ACTING SOLENOID - Steam and media at high temperatures up to 180 °C
2000 Angle-seat Valve
Port
BSPP
Orifice
mm
1/4”
2.0
Kv-value
(water m3/h)
0.12
Pressure Range
(AC)
(DC)
0-16
Weight
(g)
0-12
360
Voltage options
24V AC/DC 110/230 AC
1/4”
3.0
0.23
0-14
0-8
360
24V AC/DC 110/230 AC
3/8”
3.0
0.23
0-14
0-8
500
24V AC/DC 110/230 AC
GUNMETAL
ST/STEEL
Let us help you select the right valve to work with your flow meter and batching instrument... call for data sheets.
STRAINERS
Y-Type
Y-TYPE STRAINERS 3/8” - 10”
A selection of strainers manufactured from cast iron, bronze, ductile iron and stainless steel, all with a choice of filtration sizes.
BSP, NPT, ANSI or DIN FLANGED
SAFETY BARRIERS & ISOLATORS
Zenner Barriers, Galvanic Isolators
SHUNT-DIODE SAFETY BARRIERS & ISOLATING INTERFACES
A choice of barriers and isolators from leading manufacturers.
Pulse isolators, Trip Amplifiers, Power Supplys, Solenoid Drivers, Signal Transfer Isolators, F/DC Converters
( 0800 0277786
27
SYSTEM DESIGN & BUILD
Bell Flow Sytems in conjunction with our approved contractors, provide a comprehensive design and
build service for liquid filling and control systems.
We have a strong tradition in the print industry, where
design and install innovative solvent management systems. The
systems streamline operations, providing faster response to solvent
demand, tighter control of ink viscosity and solvent mixing, as well as
improved health and safety.
we
We also have a large number of “track-side filling” installations located in vehicle manufacturing plants
around the UK, as well as numerous bespoke menu batching systems and control systems in all areas
of industry. Our applications experience extends from simple batching and blending systems in safe
and hazardous areas, to complex menu-batching systems handling flowrates down to a few millilitres
per minute and viscosities up to several hundred thousand centipoise.
MULTIFLOW GENERAL SPECIFICATIONS
DISPLAY
High intensity alphanumeric red dot matrix (152mm wide)
POWER
110-120V AC - 220-240V AC 50-60Hz/12-24V DC
INPUT OPTIONS
15x Pulse Input (various signal types) 0.001Hz. 20kHz/Accuracy +/- 0.01Hz +/- least significant digit.
(Each may be Linearised)
30x Analogue/12 bit resolution/Accuracy: +/- 0.025% of full scale
OUTPUT OPTIONS
15x Analogue/Accuracy: +/- 0.025% of full scale
(combinations of)
15x Pulse TTL (range: 1Hz...1kHz)
35x Single pole relays ([email protected] 240V AC)
Printer/ Comms:
MULTIFLOW...the powerful flowcomputer behind many of our
batching and control systems.
RS232/485 serial/parallel bi-directional.
CAPABILITY
The Multiflow was designed to meet the ever changing needs of flow metering and can be adapted to virtually any
flow application. All Multiflow systems are specifically tailored to the customers’ requirements by the addition of the
available options and the inclusion of dedicated software. Application specific software is written on a job-by-job
basis and each application benefits from the years of experience acquired by the Multiflow to date.
The Multiflow boasts powerful information processing capabilities and utilizes true parallel processing, with channel
and card instruction routines being run at up to five million times per second.
SERVICE & CALIBRATION
Bell Flow Sytems offers scheduled recalibrations to many of our customers, with the option to
return your meter to us, or to request an on-site calibration using transfer standard meters or proven
recalibration techniques.
Calibrations are on oil or water and all meters calibrated are issued
with calibration certificates, featuring the relevant data.
Our service and commissioning options allow you peace of mind
knowing that the equipment you have purchased will be installed and
configured correctly. Providing you with the accurate and reliable
results that you need. Many spares for repairs are carried in stock
and years of experience tell us what is needed to get you working
again.
28
www.bellflowsystems.com
USEFUL TABLES
COMMON ABBREVIATIONS
download a free unit converter
from www.bellflowsystems.com
Symbol
Name
Symbol
Name
π
Ω
μS/cm
°
°C
°F
°R
A
acf
acfm
acm
acmm
atm
bar
bbl
bpd
bph
bpm
BSP
Btu
cm
cp
cSt
cm2
dm
ft
g
gal
gpm
hhp
hp
Hz
hr
in
J
K
kj
kg
kgf
km
pi, 3.1415926535897931160
ohm
microsiemens per centimetre
degree
degree Celsius
degree Fahrenheit
degree Rankine
ampere
actual cubic foot
actual cubic foot per minute
actual cubic meter
actual cubic meter per minute
atmosphere
bar
barrel
barrel per day
barrel per hour
barrel per minute
British standard pipe
British thermal unit
centimeter
centipose
centistoke
square centimeter
decimeter
foot
gram
gallon
gallon per minute (US or Imp)
hydraulic horsepower
horsepower
Hertz
hour
inch
joule
Kelvin
kilojoule
kilogram
kilogram-force
kilometer
ksi
kW
L
lb
lbf
lbm
m
m3
m3/min
m/s
md
Mgal
min
mL
mm
mPa
MPa
Mscf
NPT
newton
N s/m2
oz
Pa
PS
psf
psi
pt
rad
rpm
sack
scf
scfm
scm
scmm
SG
sk
ton
tonf
tonne
W
1000 psi
kilowatt
litre
pound
pound-force
pound (mass)
meter
cubic meter
cubic meter per minute
metre per second
millidarci
1000 gal
minute
millilitre
millimeter
millipascal
megapascal
1000 standard cubic feet
national pipe thread
newton
newtons per square centimetre
ounce
pascal
horsepower (metric)
pound per square foot
pound per square inch
pint
radian
rotation per minute
100 pound sack (mass)
standard cubic feet
standard cubic feet per minute
standard cubic meter
standard cubic meter per minute
specific gravity
cubic foot (volume)
US ton
ton-force
UK ton
watt
kPa
kilopascal
yd
yard
All of the information on these pages should be checked against other sources for accuracy in critical calculations. Most conversions are accurate to
only a few significant figures
( 0800 0277786
29
USEFUL TABLES
CONVERSION TABLES
download a free unit converter
from www.bellflowsystems.com
PRESSURE/VACUUM
inch
ft
ft
yard
Angstrom
mm
2.54
12
0.305
1.094
1010
0.0393
to get
Divide
Multiply
to get
➜
cm
inch
meter
meter
meter
inch
atm
atm
atm
atm
atm
atm
bar
bar
bar
bar
bar
bar
bar
cm of H2O
cm of H2O
cm of H2O
cm of H2O
cm of H2O
cm of H2O
“ of H2O
“ of H2O
“ of H2O
“ of H2O
“ of H2O
“ of H2O
“ of Hg
“ of Hg
“ of Hg
“ of Hg
“ of Hg
“ of Hg
kg/cm2
kg/cm2
kg/cm2
kg/cm2
kg/cm2
kg/cm2
kg/cm2
kPa
kPa
kPa
kPa
kPa
kPa
33.9
760
1033.2
14.696
1.013
101.3
14.50
401.47
29.53
100.0
1000
1019.73
750.06
0.014223
0.3937
0.028958
0.09806
0.9806
0.7355
0.036127
0.073554
0.2491
2.491
2.5400
1.8683
0.4912
13.596
3.3864
33.864
34.532
25.400
14.223
393.7
28.96
98.06
980.6
1000
735.5
0.14504
4.0147
0.2953
10.000
10.1973
7.5006
➜
FLOWRATE
Multiply
to get
➜
to get
Divide
cc/min
cfm (ft3/min)
cfm (ft3/min)
cfm (ft3/min)
cfm (ft3/min)
cfh (ft3/hr)
cfh (ft3/hr)
gal/hr (US)
gal/hr (US)
gal/min (US)
gal/min (US)
gal/min (US)
gal/hr (Imp)
gal/min (Imp)
gal/min (Imp)
1
28.32
1.699
7.481
6.228
472
0.103
63.1
0.134
0.227
3.785
0.832
75.768
0.272
4.546
mL/min
L/min
m3/hr
gal/min (US)
gal/min (Imp)
mL/min
gal/min (IMP)
mL/min
cfh
m3/hr
L/min
gal/min (Imp)
mL/min
m3/hr
L/min
Multiply
to get
➜
to get
Divide
gallons (US)
gallons (US)
litres
lb water
gallons (Imp)
cubic ft
cubic in
cubic cm
cubic meters
cubic meters
128
3.785
1000
0.119
1.2
7.48
0.00433
0.0338
264.2
1000
➜
VOLUME
fluid ounces
litres
cc’s
gallons
gallons (US)
gallons
gallons
fluid ounces
gallons (US)
litres
➜
➜
PRESSURE/VACUUM
to get
Divide
Multiply
to get
➜
ft H2O
mm Hg
g/cm2
psi
bar
kPa
psi
“ of H2O
“ of Hg
kPa
mbar
cm of H2O
mm of Hg
psi
“ of H2O
“ of Hg
kPa
mbar
mm of Hg
psi
“ of Hg
kPa
mbar
cm of H2O
mm of Hg
psi
“ of H2O
kPa
mbar
cm of H2O
mm of Hg
psi
“ of H2O
“ of Hg
kPa
mbar
cm of H2O
mm of Hg
psi
“ of H2O
“ of Hg
mbar
cm of H2O
mm of Hg
mbar
mbar
mbar
mbar
mbar
mbar
micron (µ)
micron (µ)
micron (µ)
micron (µ)
micron (µ)
micron (µ)
micron (µ)
mm of Hg
mm of Hg
mm of Hg
mm of Hg
mm of Hg
mm of Hg
oz/inch2
oz/inch2
oz/inch2
oz/inch2
oz/inch2
oz/inch2
oz/inch2
psi
psi
psi
psi
psi
psi
psi
psi
torr
torr
torr
torr
torr
torr
torr
0.01450
0.40147
0.02953
0.100
1.01973
0.75006
0.00019337
0.0053525
0.00039370
0.0013332
0.013332
0.013595
0.001
0.019337
0.53525
0.039370
0.13332
1.3332
1.3595
0.06250
1.7299
0.1272
0.4309
4.309
4.394
3.232
27.680
2.036
6.8947
68.947
0.0689
70.308
0.06804
51.715
0.019337
0.53525
0.039370
0.13332
1.3332
1.3595
1.000
➜
LENGTH
Multiply
to get
to get
Divide
psi
“ of H2O
“ of Hg
kPa
cm of H2O
mm of Hg
psi
“ of H2O
“ of Hg
kPa
mbar
cm of H2O
mm Hg
psi
“ of H2O
“ of Hg
kPa
mbar
cm of H2O
psi
“ of H2O
“ of Hg
kPa
mbar
cm of H2O
mm of Hg
“ of H2O
“ of Hg
kPa
mbar
bar
cm of H2O
atm
mm of Hg
psi
“ of H2O
“ of Hg
kPa
mbar
cm of H2O
mm Hg
➜
All of the information on these pages should be checked against other sources for accuracy in critical calculations. Most conversions are accurate to
only a few significant figures
30
www.bellflowsystems.com
➜
USEFUL TABLES
CONVERSION TABLES
(cont’d)
download a free unit converter
from www.bellflowsystems.com
Miscellaneous
➜
Feet per Second
Feet per Second
Feet per Second
Metre per Second
Metre per Second
Metre per Second
Kilometre per Hour
Kilometre per Hour
Kilometre per Hour
Mile per Hour
Mile per Hour
Mile per Hour
0.3048
1.09728
0.6818
3.281
3.600
2.237
0.9111
0.2777
0.6214
1.467
0.4471
1.609
to get
Divide
Multiply
to get
➜
to get
Divide
Metres per Second
Kilometres per Hour
Miles per Hour
Feet per Second
Kilometres per Hour
Miles per Hour
Feet per Second
Metres per Second
Miles per Hour
Feet per Second
Metres per Second
Kilometres per Hour
hp
hp
hp
hp
watts
watts
lb-ft
oz-in
oz-in
oz-in
gauss
0.746
42.44
396,000
1.014
0.7376
44.25 lb
0.1368
0.072
70,600
0.00706
0.0001
➜
Velocity
Multiply
to get
kW
Btu/min
lb in/min
metric hp
lb ft/sec
ft/min
kg-m
kg-cm
dyne-cm
Nm
tesla
➜
Volts
Comparative Particle Size
US
mesh
Inches
Microns
US
mesh
Inches
Microns
3
3-1/2
4
5
6
7
8
10
12
14
16
18
20
25
30
35
0.265
0.223
0.187
0.157
0.132
0.111
0.937
0.787
0.0661
0.0555
0.0469
0.0394
0.0331
0.0280
0.0232
0.0197
6730
5660
4760
4000
3360
2830
2380
2000
1680
1410
1190
1000
841
707
595
500
40
45
50
60
70
80
100
120
140
170
200
230
270
325
400
—
0.0165
0.0138
0.0117
0.0098
0.0083
0.0070
0.0059
0.0049
0.0041
0.0035
0.0029
0.0024
0.0021
0.0017
0.0015
—
420
354
297
250
210
177
149
125
105
88
74
63
53
44
37
—
Watts
Volts = √Watts x Ohms =
Amperes
= Amperes x Ohms
Amperes
Amperes =
Volts
Ohms
=
Watts
Volts
=
√
Watts
Ohms
Ohms
Ohms
=
Volts
Ampeers
=
Volts2
Watts
=
Watt2
Amperes
Watts
Watts
= Volts x Amperes = Amperes2 x Ohms =
(E) is the unit of electric pressure or electromotive force.
It is the potential that will produce a current of 1 ampere
through a resistance of 1 ohm.
Ampere: (I) is the unit of electrical current (coulombs per second).
(R) is the unit of electrical resistance (volts/ampere).
Ohm:
Watts: (W) and kilowatts (KW) are units of electric power.
Calculation of Volumetric Flow to Mean Velocity
°F = (1.8 x °C) + 32
Definition: The mean velocity is that velocity which directly relates to the
volumetric flow rate.
US
Mean Velocity fps =
0.408 x gpm(US)
(internal Ø inches)2
Kelvin = °C + 273.2
°Rankin = °F + 459.67
Ohms
Volt:
Temperature Conversion Equations
°C = (°F-32) x 0.555
Volts2
Metric
Mean Velocity m/s =
354 x m3/h
(internal Ø mm)2
All of the information on these pages should be checked against other sources for accuracy in critical calculations. Most conversions are accurate to
only a few significant figures
( 0800 0277786
31
USEFUL TABLES
CONVERSION TABLES
(cont’d)
download a free unit converter
from www.bellflowsystems.com
Brix Scale (sucrose)
Typical Examples - Viscosity Reference Guide
Centipoise*
(cp)
Centistokes
(cSt)
Saybolt Second Universal
(SSU)
1
2.05
1
2.56
31
35
Water
Kerosene
3.2
16.5
34.6
88
176
352
880
1561
1760
3000
5000
8640
15,200
17,640
4
20.6
43.2
110
220
440
1100
1735
2200
4500
6250
10,800
19,000
19,600
40
100
200
500
1000
2000
5000
8000
10,000
20,000
28,000
50,000
86,000
90,000
Milk
Cream
Vegetable oil
SAE 10 oil
Tomato juice
SAE 30 oil
Glycerine
SAE 50 oil
Honey
Glue
Mayonnaise
Molasses B
Sour cream
SAE 70 oil
% Brix
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
Typical liquid
*Centipoise = centistokes x specific gravity where specific gravity is assumed to be 0.8
(except for water).To find the exact cp of your fluid use the tables below.
Dynamic (Absolute) Viscosity
➜
lbf-sec/ft2
lbf-sec/ft2
centipoises
centipoises
Pascal-sec
Pascal-sec
47880.26
47.8803
0.000102
0.001
3600
1000
Dynamic to Kinematic Viscosity
to get
Divide
Multiply
to get
➜
centipoises
Pascal-sec
kg-sec/sq meter
lbf-sec/sq ft*
kg/m.h
centipoises
centipoise
1/density(g/cm3)
centistokes
centipoise
0.00067197/density(lb/ft3)
ft2/sec
lbf-sec/ft2
32.174/density(lb/ft3)
ft2/sec
kg-sec/m2
9.80665/density (kg/m3)
sq meters/sec
Pascal-sec
to get
Divide
➜
Multiply
to get
Refractive Index
1.3330
1.3403
1.3479
1.3557
1.3639
1.3723
1.3811
1.3902
1.3997
1.4096
1.4200
1.4307
1.4418
1.4532
1.4651
1.4774
1.4901
1.5003
1000/density
(g/cm3)
centistokes
➜
*Sometimes absolute viscosity is given in terms of pounds mass.
In this case - centipoises x 0.000672 = lbm/ft sec.
Kinematic to Dynamic Viscosity
Multiply
to get
➜
ft2/sec
ft2/sec
sq meters/sec
sq meters/sec
centistokes
centistokes
92903.04
0.092903
10.7639
1000000.0
0.000001
0.0000107639
to get
Divide
centistokes
sq meters/sec
ft2/sec
centistokes
sq meters/sec
ft2/sec
Multiply
to get
➜
centistokes
density (g/cm3)
to get
Divide
➜
Kinematic Viscosity
centipoises
(kg/m3)
sq meters/sec
0.10197 x density
ft2/sec
0.03108 x density (lb/ft3)
ft2/sec
(lb/ft3)
1488.16 x density
3
centistokes
0.001 x density (g/cm )
sq meters/sec
1000 x density (g/cm )
3
kg-sec/sq meter
lbf-sec/ft2
centipoises
Pascal-sec
Pascal-sec
➜
All of the information on these pages should be checked against other sources for accuracy in critical calculations. Most conversions are accurate to
only a few significant figures
32
www.bellflowsystems.com
USEFUL TABLES
ENCLOSURE RATINGS
NEMA, UL & CSA to approximate
IEC/IP classification
Conversion of NEMA type classifications to IEC classification designation (IP ratings)
Note: NEMA standards meet or exceed IEC standards; therefore, the conversion does not work in the opposite direction.
(There is no direct equivalent)
NEMA
enclosure
type
NEMA DEFINITION
IEC
enclosure
class
1
Indoor use primarily to provide a degree of protection against contact with the enclosed equipment and
against a limited amount of falling dirt.
IP30
2
Indoor use to provide a limited degree of protection against limited amounts of falling water and dirt.
IP31
3
Provides a degree of protection against weather hazards such as wind blown dust, rain and sleet; for use
outdoors and remains undamaged by the formation of ice on the enclosure.
IP64
3R
Intended for outdoor use. Provides a degree of protection against falling rain and ice formation. Meets rod
entry, rain, external icing, and rust-resistance design tests.
IP32
4
Indoor or outdoor use to provide a degree of protection against splashing water and weather hazards such
as wind blown dust, rain and sleet, as well as hose directed water. Remains undamaged by the formation of
ice on the enclosure.
IP66
4X
Indoor or outdoor use to provide a degree of protection against splashing water and weather hazards such
as wind blown dust, rain and sleet, as well as hose directed water. Remains undamaged by the formation of
ice on the enclosure and resists corrosion.
IP66
6 & 6P
Indoor or outdoor use to provide a degree of protection against splashing water and weather hazards such
as wind blown dust, rain and sleet, as well as hose directed water. Remains undamaged by the formation of
ice on the enclosure. Submersible in water (design depends on specified conditions of pressure and time.)
IP67
11
Indoor use to provide by oil immersion a degree of protection of the enclosed equipment against the effects
of corrosive liquids and gas.
—
12 & 12K
Indoor use to provide a degree of protection against dust, falling dirt and dripping non corrosive liquid.
Meets drip, dust, and rust resistance tests.
IP55
13
General-purpose. Primarily used to provide protection against dust, spraying of water, oil, and noncorrosive coolants. Meets oil exclusion and rust resistance design tests
IP65
Ingress Protection (IP) Ratings IEC/EN 60529
The IP rating system provides a means of classifying the degrees of protection from solid objects and liquids afforded by electrical equipment and enclosures.
First number Protection against solid objects
0
1
2
3
4
5
6
no protection
protected against
protected against
protected against
protected against
protected against
dust tight
solid objects up to 50 mm (e.g. accidental touch by hands)
solid objects up to 12 mm (e.g. fingers)
solid objects up to 2.5 mm (e.g. tools and small wires)
solid objects up to 1 mm (e.g. tools and small wires)
dust - limited ingress permitted (no harmful deposits)
Second number Protection against liquids
0
1
2
3
4
5
6
7
0
no protection
protected against
protected against
protected against
protected against
protected against
protected against
protected against
no protection
vertically falling drops of water (e.g. condensation)
direct sprays of water up to 15° from the vertical
direct sprays of water up to 60° from the vertical
water sprayed from all directions—limited ingress permitted
low pressure jets of water sprayed from all directions—limited ingress permitted
strong jets of water—limited ingress permitted (e.g. for use on ship decks)
the effects of immersion between 15 cm and 1
All of the information on these pages should be checked against other sources for accuracy in critical calculations. Most conversions are accurate to
only a few significant figures. Bell Flow Systems accepts no responsibility for the accuracy of these tables or their use.
( 0800 0277786
33
LAB 2002
Bell Flow Systems Ltd
426 Westcott Venture Park, Aylesbury, Bucks, HP18 OXB
FREEPHONE UK. 0800 027 7786  Tel Int’l +44 (0)1296 658600  Fax. +44(0) 1296 658515
e-mail: [email protected] bellflowsystems.com
www.bellflowsystems.com
Was this manual useful for you? yes no