D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual CONTENTS 1 Overview ..................................................................................................................... 1 2 Specification ............................................................................................................... 1 3 Construction and Operation Principle..................................................................... 2 3.1 Construction .......................................................................................................... 2 3.2 Adjustment Frame ................................................................................................. 3 3.3 Operation Principle................................................................................................ 3 4 Installation and Connection...................................................................................... 3 4.1 Installation ............................................................................................................. 3 4.2 Connection ............................................................................................................ 4 5 Testing ......................................................................................................................... 6 6 Operation .................................................................................................................... 6 7 Application .................................................................................................................. 7 8 Troubleshooting ......................................................................................................... 7 9 Maintenance ............................................................................................................... 8 10 Caution ...................................................................................................................... 8 11 Accessories .............................................................................................................. 8 Page I D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual 1 Overview Dual-band infrared light detection for fire alarm. Sensitive to flame from material containing carbon. Suitable for fire starting from flame in large indoor or outdoor areas. Addressable (connecting fire alarm control panel) and non-addressable (through relay contact) working modes optional. Flame-proof. Applicable to either commercial or hazardous industrial areas, such as explosive Zone 1 and 2, and Zone 21 and 22 with flammable dust. 2 Specification Operating Voltage: Loop: Range 16V~28V 24VDC: Range 20VDC~28VDC Operating Current: Loop: Standby current≤ 1mA, alarm current≤1mA, Maximum Consumption 28mW 24VDC: Standby current ≤ 20mA, alarm current ≤ 30mA, Maximum Consumption:840mW Sensitivity Level: The detector has three sensitivity levels. The factory default sensitivity is Level I, which can be reduced in field using GST handheld programmer. Detection Distance: Sensitivity Level I: 25m (furthest) Sensitivity Level II: 17m Sensitivity Level III: 12m Test Fire: 33cm×33cm n-heptane fire. The correlation between detection distance and angle is shown in Fig. 1. The shaded area is detectable. The semicircle in the figure represents the detection distance in percentage. furthest 15 o 0o 15o 30 o 30o 45o 100% 45o 50% Detector Fig. 1 Page 1 50% 100% D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual Note: The detection angle to all directions are the same. Fig. 1 only gives a section illustration. Response Spectral Range: 4.4μ m±0.5μ m Response Time ≤30s Indicators: Red LED: Flashes periodically in standby state, and steadily illuminates in fire alarm. Yellow LED: Off in standby state, and steadily illuminates in fault. Contact Output: Fire alarm contact: 1A/25VDC, normally closed in fire alarm, and normally open in other states. Fault contact: 1A/25VDC, normally open in fault state, and normally closed in other states. Operating Environment: Temperature: -20℃~+55℃ Relative Humidity: ≤95%, non-condensing Ingress Protection: IP66 Dimensions: 166mm×235mm×199mm (with adjustment frame) Installation Hole Space: 125.5mm×80mm Material and Color of Enclosure: Stainless steel, metallic grey Weight: Detector: 4.8kg Adjustment frame: 1.3kg Explosion-proof Mark: Exd IIC T6 Gb/DIP A21 TA,T6 Explosion-proof Certificate Number: CE11.1229 Standard: GB 3836.1-2010,GB 3836.2-2010,GB 12476.1-2000,EN54-10 3 Construction and Operation Principle 3.1 Construction The construction of the detector is shown in Fig. 2. Adjustment Frame Securing Bolt Fire LED Detection Window Fault LED Axes Cap Earth Page 2 Cable Junction D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual Fig. 2 3.2 Adjustment Frame The adjustment frame can rotate by 60°around the axe, as shown in Fig. 3. Fig. 3 3.3 Operation Principle The detector uses two pyroelectric infrared sensors to detect the change of light signal of flame and background light signal at two bands of infrared spectrum through two signal processing channels. Its microprocessor analyzes the signal through the flame channel and background channel to judge if there is flame. 4 Installation and Connection 4.1 Installation Before installation, check first if the enclosure is in good condition with all necessary markings. Then set the detector address and sensitivity level (please refer to Section 6 Operation), and then install it according to Fig. 4. M Base Wall Frame lt Bo p4 S te p1 Ste Page 3 Step 3 p2 Ste p ca et ck so 25 n × go 8 xa s M h e r ew sc cover rew c 5s D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual Fig. 4 Step 1: Install the adjustment frame. Fix the adjustment frame securely on the wall using 4 M6 expansion bolts. Step 2: Install the base. Remove the protective cover (Fig. 5) from the base leaving the screws and washer with the base, and install the base onto the adjustment frame using a M5 screw. Aligning Element Protective Cover Fig. 5 Step 3: Cable connection. Pleaser refer to “Connection” section. Step 4: Install the cover. Remove the protective washer, insert the ribbon cable to XT3 of the base circuit, and then install the enclosure onto the base with reference to the aligning element with the U-shaped slot and secure the four screws using an Allen key. Note: The base and enclosure shall be securely installed. There shall not be any scratches or cracks on the detection window. The enclosure shall be earthed. Protective washer U-shaped slot Fig. 6 Finally, adjust the frame to make sure the detection window is facing the protected area, and fix the screws after adjustment. Note: The detector shall be installed in compliance with relative installation codes and make sure the enclosure is in good condition. Please always contact your installer in case of any off-normal condition. Never conduct maintenance or repair with the power on. 4.2 Connection (1) It is recommended to use multi-core copper cable with core cross section≥ Page 4 D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual 1.0mm 2, and external diameter 8mm~10mm. (2) The cable shall meet field requirements on resistance to explosion, heat, corrosion and fire. (3) The cable layout for hazardous explosive area must comply with corresponding codes. The connecting cable can be copper-core screened cable or explosion-proof hose with suitable junction thread matching with the detector taper thread of the cable nut (Fig. 7). (4) The cable must enter the detector through the junction nut, and there must be an O-ring, a seal and a washer, as shown in Fig. 7. Fig. 7 (5) Connect the screen cover of the cable with the protective earth inside the detector. (6) Terminals on the base are shown in Fig. 8. FT1 FT2 AL1 AL2 Fig. 8 Z1, Z2: Communication loop input from fire alarm control panel. Polarity insensitive. D1, D2: 24VDC power input. Polarity insensitive. AL1, AL2: Fire alarm contact output. Normally open contact. Closed in fire alarm. FT1, FT2: Fault contact output. Normally closed contact. Open in fault. The loop cable and the power shall enter the detector through a cable nut, and the signal cable through another cable nut (Fig. 9). If no signal cable is needed, the cable inlet shall be inserted with an end cap with O-ring. If Z1 and Z2 does not connect with the loop, they must be connected with D1 and D2 polarity-insensitively. Page 5 D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual Loop and 24VDC cable inlet Contact Signal cable outlet Fig. 9 (7) After connection, screw down the cable nut. 5 Testing Warning: Power up only after all detectors are installed. 1 The detector must be tested after installation and regular maintenance. 2 Tests: (1) Connect the detector to loop and 24VDC, it should be able to be registered by the control panel, and the red LED should flash periodically. After the detector is powered up for 20 minutes, igniting an infrared light source at 1.5m distance in front of it, it shall report a fire alarm to the control panel within 30s and light the fire LED, and it should be reset from the control panel to standby state. (2) Connect the detector to 24VDC only, the red LED should flash periodically in standby state. After the detector is powered up for 20 minutes, igniting an infrared light source at 1.5m distance in front of it, it shall give fire signal within 30s and light the fire LED. 3 After testing, reset the detector from control panel if it connects to the loop. If it’s not connected to loop, disconnect 24VDC power and re-power it up. Notify the proper authorities the system is back in operation. 4 If a detector fails in testing, clean and test it again. If it still fails, return it for repair. 6 Operation 1 2 The address and sensitivity level can be programmed using a handheld programmer. Please refer to the manual for the programmer. The range of address is 1~242. For setting sensitivity level, number 1 represents sensitivity level I, number 2 for level II and number 3 for level III. If the detector connects with the loop, it needs to be programmed with an address Page 6 D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual to be identified by the control panel. If it doesn’t connect with the loop, no address setup is required. But terminal Z1 and Z2 must be connected with D1 and D2 in an polarity-insensitive way. 7 Application 1 Fig. 10 shows the connection of the detector with GST fire alarm control panel. Fire Alarm Control Panel 2 Infrared Flame Detector Power FT1 FT2 AL1 AL2 D1 D2 Z1 Z2 Loop Fig. 10 Connection of the detector with control panels of other suppliers are shown in Fig. 11. Infrared Flame Detector Fault Signal Input Fire Alarm Signal Input FT1 FT2 AL1 AL2 D1 D2 Z1 Z2 Power Control Unit Fig. 11 8 Troubleshooting Possible Problem The indicator doesn’t flash Incorrect contact signal Resolution Check the cable connection. If there is no problem, replace the detector. Page 7 D-9107RExd Digital Flame Proof Dual IR Flame Detector Installation and Operation Manual Registration failure Other problems 9 Maintenance 1 2 3 The detection window should be cleaned at least every three months. Before cleaning, notify relative departments that the system is undergoing maintenance and will be out of service. Disable the zone or system in maintenance to avoid unwanted alarms. After cleaning, install the detector back and test again. 10 Caution (1) The detector should be handled with care during maintenance to avoid damage. (2) Installation and maintenance should strictly comply with relative codes for explosive and hazardous areas. (3) Never open the cover for maintenance in field. (4) The enclosure must be earthed. (5) False alarms may occur if there is arc welding operation within 5 meters to the detector. (6) The following places are not suitable for the detector: Where flameless fires are to be expected. Where intensive smoke spreads before flames. Where the "view" of the detector is easy to be obscured. Where the sun can directly shine the detection window. Where the detector may encounter frequent vibration. 11 Accessories 1 installation and operation manual 4 M6×60 expansion bolts 1 M5×10 screws 1 adjustment frame 1 Allen Key Page 8 Gulf Security Technology Co., Ltd. No. 80, Changjiang East Road, QETDZ, Qinhuangdao, Hebei, P. R. China 066004 Tel: +86 (0) 335 8502434 Fax: +86 (0) 335 8502532 [email protected] www.gst.com.cn
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement