RT 1-10KVA UPS RT 6-10K FEATURES HIGH POWER DENSITY RACK-TOWER 2-IN-1 TRUE DOUBLE CONVERSION ONLINE UPS RT 1-3K DSP Control 0.9 Output Power Factor Wide Input Range High Efficiency Mode(ECO) Frequency Converter Mode Input THDi<5% Output Voltage Regulation <1% Output THDv<2% Fan Speed Control FEATURES Compact Design Extendable Run Time Dual input (for 6-10KVA) Power Management Software Multiple Communication Ports Optional SNMP & Relay Cards Temperature Compensation PDU(for 6-10KVA) 1+1 Parallel for 6-10KVA FEATURES 1-3K REAR PANEL 1 1-2K 2KS 1 3K 2 5 5 2 5 2 6 7 3 4 1. AC OUTPUT 2. EPO/Dry-Contact Input Port 3. USB Port 4. AC Input 5. Dry-Contact Port 6. Intelligent Slot 7. RS232 Port 8. Earth Line Port 8 7 3 7 6 8 4 3KS 2 3 5 6K REAR PANEL 1. Ground Screw 2. EPO Port 3. Parallel Port (Optional) 4. Output Socket 5. Output Circuit Breaker 6. Maintenance Bypass Switch 7. Intelligent Slot 8. USB Port 9. RS-232 Port 10.Input/Output Terminal Block 6KS 1 7 2 3 9 8 10 5 6 6K 2 3 4 5 10K REAR PANEL 10KS 1 7 6 8 2 3 4 5 9 10 10K 1. Intelligent Slot 2. Parallel Port (Optional) 3. USB Port 4. RS-232 Port 5. External Battery Connector 6. Output Circuit Breaker 7. Output Socket 8. EPO Port 9. Maintenance Bypass Switch 10.Input/Output Terminal Block 4 RT 1-3KVA UPS SPECIFICATION MODEL CAPACITY 1K VA/W 1KS 1.5K 1000VA/900W 2K 1500VA/1350W Voltage Range Phase 2000VA/1800W < 5% with Full Load Power Factor ≥ 0.99@R Full Load ±1% Frequency (Synchronized Range) 45-55Hz/54-66Hz Frequency(BAT Mode) 50/60Hz±0.2Hz Current Crest Ratio 3:1 ≤ 2% @Linear Load Harmonic Distortion ≤ 5% @Non-linear Load Output Waveform INDICATOR AUDIBLE ALARM 12s @102%-130% Load 1.5s @130%-150% Load 100ms@>150% Load BAT Mode Line Mode >88% >89% >92% BAT Mode >83% >83% >86% ECO Mode >95% >95% >95% 3 Battery Type 12V/7.2Ah Backup Time >5 Minutes Recharge Time 3 Hours to 90% Charging Current(max) TRANSFER TIME Pure Sine Wave Line Mode Number of Batteries BATTERY 1.5A Depend on The Capacity of External Batteries 6A ENVIRONMENT 12V/7.2Ah >5 Minutes 3 Hours to 90% Depend on The Capacity of External Batteries 4 12V/9Ah >5 Minutes 3 Hours to 90% 6A 0ms INV <--> BYPASS 0ms INV -->ECO 1ms ECO --> INV <10ms LCD Sounding Every 4 Seconds Low Battery Sounding Every Second Fault Continuously Sounding 438×86.5×436 Operation Environment 0-40℃ Relative Humidity EPO 12V/9Ah >5 Minutes 3 Hours to 90% 6A 1.5A Depend on The Capacity of External Batteries 6A Sounding Twice Every Second Rack Case(WxHxD)mm Intelligent Slot 6 Load Level/Battery Voltage/Battery Mode/AC Mode/Bypass Mode Information BAT Mode RS232/USB Depend on The Capacity of External Batteries 1.5A LINE <--> BAT Noise Level INTERFACE 4 1.5A Overload DIMENSION 3000VA/2700W 208/220/230/240VAC Voltage Regulation EFFICIENCY 3KS Single Phase with Ground THDI Overload Capacity 3K 45-55Hz / 54-66Hz Voltage OUTPUT 2KS 120~276VAC Depends on Load Level Frequency Range INPUT 1.5KS 438×86.5×608 0-95%(Non-Condensing) <45dB @ Front 1 Meter <45dB @ Front 1 Meter <50dB @ Front 1 Meter Software Supports Windows Family,Linux,Sun Solaris, IBM Aix,Compaq True64,SGIIRIX,FreeBSD,HP-UX,MAC SNMP/AS400/Relay Card Emergency Power Off RT 6-10KVA UPS SPECIFICATION MODEL CAPACITY 6K VA/W 6KS 10K 6000VA/5400W 10000VA/9000W Voltage Range 120~276VAC Frequency Range INPUT 45-55Hz / 54-66Hz Phase Single Phase with Ground THDI < 5% with full load Power Factor ≥ 0.99@R full load Voltage 208/220/230/240VAC Voltage Regulation ±1% Frequency (Synchronized Range) 45-55Hz/54-66Hz Frequency(BAT Mode) 50/60Hz±0.1Hz Current Crest Ratio OUTPUT 3:1 ≤ 2% @Linear load Harmonic Distortion ≤ 5% @Non-linear load Output Waveform Overload Capacity EFFICIENCY 2min @102% ~ 130% 30s @130%~150% 100ms @>150% BAT Mode 10s @102% ~ 130% 100ms @>130% Line Mode >92% >93% BAT Mode >89% >90% ECO Mode >96% >97% 12V/5Ah Backup Time >2.5minutes Charging Current(max) INDICATOR 15 Battery Type Recharge Time TRANSFER TIME Pure Sine Wave Line Mode Number of Batteries BATTERY 3 hours to 90% 1.0A INTERFACE >3.5minutes 3 hours to 90% 8.0A 1.7A INV <--> BYPASS 0ms INV-->ECO 1ms ECO--> INV <10ms LCD Fault Continuously sounding Relative Humidity 8.0A Sounding every 4 seconds Sounding every second Rack Case(WxHxD)mm Depend on the capacity of external batteries Load level/Battery voltage/Battery Mode/AC Mode/Bypass Mode Information Low Battery Operation Environment ENVIRONMENT 12V/9Ah 0ms Overload DIMENSION 20 Depend on the capacity of external batteries LINE<--> BAT BAT Mode AUDIBLE ALARM 10KS Sounding twice every second 438x129x594 438x129x594 438x215.5x594 438x215.5x594 0-40℃ 0-95%(Non-Condensing) Noise Level <55dB @ Front 1 meter RS232/USB Software supports Windows Family,Linux,Sun Solaris, IBM Aix,Compaq True64,SGIIRIX,FreeBSD,HP-UX,MAC Intelligent Slot SNMP/AS400/Relay Card EPO Emergency Power Off
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement