Axil RT


Add to my manuals
4 Pages

advertisement

Axil RT | Manualzz
RT 1-10KVA UPS
RT 6-10K
FEATURES
HIGH POWER DENSITY
RACK-TOWER
2-IN-1 TRUE DOUBLE
CONVERSION
ONLINE UPS
RT 1-3K
DSP Control
0.9 Output Power Factor
Wide Input Range
High Efficiency Mode(ECO)
Frequency Converter Mode
Input THDi<5%
Output Voltage Regulation <1%
Output THDv<2%
Fan Speed Control
FEATURES
Compact Design
Extendable Run Time
Dual input (for 6-10KVA)
Power Management Software
Multiple Communication Ports
Optional SNMP & Relay Cards
Temperature Compensation
PDU(for 6-10KVA)
1+1 Parallel for 6-10KVA
FEATURES
1-3K REAR PANEL
1
1-2K
2KS
1
3K
2
5
5
2
5
2
6
7 3
4
1. AC OUTPUT
2. EPO/Dry-Contact Input Port
3. USB Port
4. AC Input
5. Dry-Contact Port
6. Intelligent Slot
7. RS232 Port
8. Earth Line Port
8
7
3 7
6
8 4
3KS
2 3
5
6K REAR PANEL
1. Ground Screw
2. EPO Port
3. Parallel Port (Optional)
4. Output Socket
5. Output Circuit Breaker
6. Maintenance Bypass Switch
7. Intelligent Slot
8. USB Port
9. RS-232 Port
10.Input/Output Terminal Block
6KS
1 7 2 3 9 8
10
5
6
6K
2
3 4
5
10K REAR PANEL
10KS
1
7
6 8 2
3 4
5
9
10
10K
1. Intelligent Slot
2. Parallel Port (Optional)
3. USB Port
4. RS-232 Port
5. External Battery Connector
6. Output Circuit Breaker
7. Output Socket
8. EPO Port
9. Maintenance Bypass Switch
10.Input/Output Terminal Block
4
RT 1-3KVA UPS SPECIFICATION
MODEL
CAPACITY
1K
VA/W
1KS
1.5K
1000VA/900W
2K
1500VA/1350W
Voltage Range
Phase
2000VA/1800W
< 5% with Full Load
Power Factor
≥ 0.99@R Full Load
±1%
Frequency
(Synchronized Range)
45-55Hz/54-66Hz
Frequency(BAT Mode)
50/60Hz±0.2Hz
Current Crest Ratio
3:1
≤ 2% @Linear Load
Harmonic Distortion
≤ 5% @Non-linear Load
Output Waveform
INDICATOR
AUDIBLE ALARM
12s @102%-130% Load
1.5s @130%-150% Load
100ms@>150% Load
BAT Mode
Line Mode
>88%
>89%
>92%
BAT Mode
>83%
>83%
>86%
ECO Mode
>95%
>95%
>95%
3
Battery Type
12V/7.2Ah
Backup Time
>5 Minutes
Recharge Time
3 Hours to
90%
Charging Current(max)
TRANSFER TIME
Pure Sine Wave
Line Mode
Number of Batteries
BATTERY
1.5A
Depend
on The
Capacity
of External
Batteries
6A
ENVIRONMENT
12V/7.2Ah
>5 Minutes
3 Hours to
90%
Depend
on The
Capacity
of External
Batteries
4
12V/9Ah
>5 Minutes
3 Hours to
90%
6A
0ms
INV <--> BYPASS
0ms
INV -->ECO
1ms
ECO --> INV
<10ms
LCD
Sounding Every 4 Seconds
Low Battery
Sounding Every Second
Fault
Continuously Sounding
438×86.5×436
Operation Environment
0-40℃
Relative Humidity
EPO
12V/9Ah
>5 Minutes
3 Hours to
90%
6A
1.5A
Depend
on The
Capacity
of External
Batteries
6A
Sounding Twice Every Second
Rack Case(WxHxD)mm
Intelligent Slot
6
Load Level/Battery Voltage/Battery Mode/AC Mode/Bypass Mode Information
BAT Mode
RS232/USB
Depend
on The
Capacity
of External
Batteries
1.5A
LINE <--> BAT
Noise Level
INTERFACE
4
1.5A
Overload
DIMENSION
3000VA/2700W
208/220/230/240VAC
Voltage Regulation
EFFICIENCY
3KS
Single Phase with Ground
THDI
Overload
Capacity
3K
45-55Hz / 54-66Hz
Voltage
OUTPUT
2KS
120~276VAC Depends on Load Level
Frequency Range
INPUT
1.5KS
438×86.5×608
0-95%(Non-Condensing)
<45dB @ Front 1 Meter
<45dB @ Front 1 Meter
<50dB @ Front 1 Meter
Software Supports Windows Family,Linux,Sun Solaris,
IBM Aix,Compaq True64,SGIIRIX,FreeBSD,HP-UX,MAC
SNMP/AS400/Relay Card
Emergency Power Off
RT 6-10KVA UPS SPECIFICATION
MODEL
CAPACITY
6K
VA/W
6KS
10K
6000VA/5400W
10000VA/9000W
Voltage Range
120~276VAC
Frequency Range
INPUT
45-55Hz / 54-66Hz
Phase
Single Phase with Ground
THDI
< 5% with full load
Power Factor
≥ 0.99@R full load
Voltage
208/220/230/240VAC
Voltage Regulation
±1%
Frequency
(Synchronized Range)
45-55Hz/54-66Hz
Frequency(BAT Mode)
50/60Hz±0.1Hz
Current Crest Ratio
OUTPUT
3:1
≤ 2% @Linear load
Harmonic Distortion
≤ 5% @Non-linear load
Output Waveform
Overload
Capacity
EFFICIENCY
2min @102% ~ 130%
30s @130%~150%
100ms @>150%
BAT Mode
10s @102% ~ 130%
100ms @>130%
Line Mode
>92%
>93%
BAT Mode
>89%
>90%
ECO Mode
>96%
>97%
12V/5Ah
Backup Time
>2.5minutes
Charging Current(max)
INDICATOR
15
Battery Type
Recharge Time
TRANSFER TIME
Pure Sine Wave
Line Mode
Number of Batteries
BATTERY
3 hours to 90%
1.0A
INTERFACE
>3.5minutes
3 hours to 90%
8.0A
1.7A
INV <--> BYPASS
0ms
INV-->ECO
1ms
ECO--> INV
<10ms
LCD
Fault
Continuously sounding
Relative Humidity
8.0A
Sounding every 4 seconds
Sounding every second
Rack Case(WxHxD)mm
Depend on
the capacity
of external
batteries
Load level/Battery voltage/Battery Mode/AC Mode/Bypass Mode Information
Low Battery
Operation Environment
ENVIRONMENT
12V/9Ah
0ms
Overload
DIMENSION
20
Depend on
the capacity
of external
batteries
LINE<--> BAT
BAT Mode
AUDIBLE ALARM
10KS
Sounding twice every second
438x129x594
438x129x594
438x215.5x594
438x215.5x594
0-40℃
0-95%(Non-Condensing)
Noise Level
<55dB @ Front 1 meter
RS232/USB
Software supports Windows Family,Linux,Sun Solaris,
IBM Aix,Compaq True64,SGIIRIX,FreeBSD,HP-UX,MAC
Intelligent Slot
SNMP/AS400/Relay Card
EPO
Emergency Power Off

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement