American Standard Cadet 4112.600 User's Manual

Add to my manuals
1 Pages

advertisement

American Standard Cadet 4112.600 User's Manual | Manualzz
CADET™
ROUND FRONT TOILET
VITREOUS CHINA
CADET™ ROUND FRONT TOILET
❑ 2798.012
•Vitreous china
•Low-consumption (6.0 Lpf/1.6 gpf)
•Round front siphon action jetted bowl
•Fully glazed 2" trapway
•AquaForce flushing technology
•Close-coupled tank with raised lip detail on
tank cover
•Color-matched trip lever
•Speed Connect ® tank/bowl coupling system
•Sanitary bar on bowl
•2 bolt caps
•100% factory flush tested
❑ 3454.016 Bowl
❑ 4112.016 Tank
Nominal Dimensions:
699 x 495 x 762mm (27-1/2" x 19-1/2" x 30")
FINISHED WALL
699mm
(27-1/2)
Fixture only, seat and supply by others
Compliance Certifications Meets or Exceeds the Following Specifications:
• ASME A112.19.2M for Vitreous China Fixtures includes Flush Performance, Ball Pass Diameter,
Trap Seal Depth and all Dimensions
To Be Specified:
❏ Color: ❏ White ❏ Bone ❏ Linen ❏ Silver
❏ Fawn Beige ❏ Black
❏ Seat: American Standard #5322.011 “Rise and
Shine” solid plastic closed front seat with cover.
❏ Seat: American Standard #5308.014 “Laurel”
molded closed front seat with cover.
❏ Alternate Seat:
❏ Supply with stop:
© 2008 AS America Inc.
495mm
(19-1/2)
225mm
(8-7/8)
419mm
(16-1/2)
C/L OF SEAT POST HOLES
140mm (5-1/2 CENTERS)
762mm
(30)
SUPPLY
AS
REQ'D
83mm
(3-1/4)
Alternate Tank Configurations Available:
❑ 4112.300 Tank complete with chrome all metal trip lever
❑ 4112.500 Tank complete with Aquagard Liner
❑ 4112.600 Tank complete with tank cover
locking device
❑ 4112.700 Tank complete with Aquagard Liner and tank cover locking device
❑ 4112.800 Tank complete with trip lever located on right side
❑ 4112.900 Tank complete with tank cover device
and trip lever located on right side
19mm ± 6mm
(3/4 ± 1/4)
381mm
(15)
*222mm
(8-3/4)
16mm
(5/8)
178mm
(7)
305mm
(12)
305mm
(12)
381mm
(15)
152mm
(6)
FINISHED
FLOOR
241mm
(9-1/2)
C/L OF OUTLET
NOTES:
THIS COMBINATION IS DESIGNED TO ROUGH-IN AT A MINIMUM DIMENSION
OF 305MM (12") FROM FINISHED WALL TO C/L OF OUTLET.
DIMENSION SHOWN FOR LOCATION OF SUPPLY IS SUGGESTED.
*SUPPLY
NOT INCLUDED WITH FIXTURE AND MUST BE ORDERED
SEPARATELY.
IMPORTANT: Dimensions of fixtures are nominal and may vary within the range
of tolerance established by ANSI Standard A112.19.2
These measurements are subject to change or cancellation. No responsibility is
assumed for use of superseded or voided pages.