short form catalog
SHORT FORM CATALOG
DEWETRON
DEWETRON –
WE SET STANDARDS
DEWETRON is the market-leading producer
of universal test and measurement systems.
DEWETRON‘s great strengths are in supplying
complete systems that are immediately ready for use
while also being quickly customizable to the unique
needs of the test environment.
DEWETRON has more than 25 years of
expertise in measurement engineering and
technology. The PC-based systems are
suitable for mobile use, modular in design
and can therefore be extended as desired.
DEWETRON systems are compatible with
all common sensors available on the market.
Together with our powerful measurement
amplifiers, DEWETRON systems will guarantee you accurate, immediate results from
your test series.
DEWETRON
A SUCCESS STORY
DEWETRON was established in 1989 as a
purveyor of PC components and measuring
instruments. At that time the market for PC
based measuring systems was just emerging and being identified as a promising
segment with great potential for growth.
In response to the potential, DEWETRON
expanded into producing it’s own measurement systems and measurement software.
As the test and measurement market
evolved so did DEWETRON, introducing the
concept of “modular logic”. The modular ap-
GENERAL SOLUTIONS
AUTOMOTIVE
AEROSPACE
ENERGY & POWER ANALYSIS
TRANSPORTATION
2
proach to test and measurement combines
application specific systems with customer
specific requirements to create a high level
of quality in a short time. Customization
was a part of DEWETRON’s philosophy long
before it became an industry standard.
For 25 years DEWETRON has set new
standards for test and measurement
systems. Today, customers from more than
25 countries worldwide rely on our products
for precision measurement recording
and analysis. DEWETRON is certified in
accordance with ISO 9001:2008 and ISO
14001:2009. Environmental and quality
management is more than just a statutory
obligation for us – it is an integral part of
all our business processes. We continually
strive to combine innovation and business
success with strict quality standards and
rigorous quality processes. It is for this
reason that we are recognized as a reliable
partner.
SHORT FORM CATALOG
DEWETRON
CUSTOMERS
There are more than 20,000 DEWETRON
measuring systems and over 300,000
measuring channels in use in well known
companies worldwide:
PROJECT PLANNING
AND CONSULTING
DEWETRON systems provide the complete
technical solution to test and measurement projects and DEWETRON employees
provide a wide range of project planning and
data management expertise. As your project
partner we are always available to answer
questions related to initial project planning,
post implementation data management and
technical support whenever you need it.
WORLDWIDE
SUPPORT
In the world of test and measurement, testing time is often short so there is no room
for downtime. Knowing this, DEWETRON
provides prompt, efficient technical support
worldwide. With 150 employees working
in over 25 countries technical and sales
support is always available and has been for
more than 25 years. Our support success is
measured by over 20,000 DEWETRON systems and 300,000 measurement channels
in continuous use in the worldwide Automotive, Aerospace, Energy & Power Analysis,
and Transportation markets.
QUALITY
Total Quality Management starts with an
understanding of what is important to
ensure the success of our customers.
Our commitment to quality begins with
defined technical specifications and continues through product development, delivery
and on to the support and service of our
products.
DEWETRON is ISO 9001:2008 and ISO
1401:2009 certified. Environmental
and Quality Management are more than
compliance, they are an integral part of our
operation. All DEWETRON products are
tested at our Environmental Test Facility in
Graz, Austria before being delivered.
AIRBUS, AUDI, BOEING, BOMBARDIER,
BRIDGESTONE, BMW, CONTINENTAL,
DEUTSCHE BAHN, ELECTRO SUISSE,
EADS, FERRARI, FIAT, FORD, FRAUNHOFER INSTITUTE, GOODYEAR, HARLEY
DAVIDSON, HYUNDAI, HELICOPTER
INSTITUTE CHINA, IVECO, JOHNSON &
JOHNSON, KENNEDY SPACE CENTER,
LUFTHANSA, MAGNA STEYR, MAN,
MERCEDES BENZ, METRO MADRID, NEW
YORK SUBWAY, NISSAN, NASA, NOKIA,
OMV, PANASONIC, PIRELLI, PORSCHE,
RENAULT, ROLLS ROYCE, SIEMENS,
SHANGHAI GM, TOYOTA, UNIVERSITY OF
VIENNA, US AIR FORCE EDWARDS FLIGHT
TEST CENTER, US NAVY, VOLVO, VW,
VOEST, YAMAHA AND MANY MORE.
CALIBRATION
DEWETRON maintains two high tech
calibration labs: one at the worldwide
headquarters in Austria and the other one
at the DEWETRON USA headquarters in
Rhode Island. Both calibration labs employ
the Fluke 5500 series calibrator and the
Agilent 3458 multimeter. METCAL calibration software automates nearly every
process for precision calibration.
Additionally to the standard calibration,
we offer accredited calibration according to
EN ISO/IEC 17025.
3
DEWETRON
WHY
DEWETRON?
SYNC-CLOCK™
TECHNOLOGY
COUNTER
The quality of synchronized measurement
is guaranteed by SYNC-CLOCK™ technology. With SYNC-CLOCK technology, analog,
digital, GPS, counter, CAN-bus, ARINC
and video as well as major sensor systems
like Kistler RoaDyn® 2000 wheel or the
GeneSys ADMA INS/GPS system are
recorded synchronously during measurement.
Counter/encoder inputs of TRION™ modules are phase synchronized. Referring to
the diagram, you can see that a standard
counter is always a sample behind. With
software interpolation you can get closer,
but only DEWETRON’s advanced technology is both, fully phase AND amplitude
corrected.
HIGHEST
PRECISION
TRION™ series modules easily integrate
with all similar products on the market.
ADC-CLOCK
COUNTER INPUT
IDEAL COUNTING
DEWETRON COUNTER
SOFTWARE INTERPOLATION
STANDARD COUNTER
4
SCALABLE AND
MODULAR
USER EXCHANGEABLE MODULES
GLOBAL
SUPPORT
Expand from a few channels to many and
connect many systems without compromising the simultaneous data sampling of
all channels.
TRION™ amplifier modules can be changed
in seconds. Modules with different sampling speed and resolution can be used in
one chassis. Use isolated and differential
inputs at the same time.
Our engineers are in 25 countries around
the world to support you with their
knowledge and expertise. We offer maintenance, upgrades, ISO certified system
calibrations and also customer training!
SHORT FORM CATALOG
TABLE OF
CONTENTS
OVERVIEW
Instrument Families ..................................................................6
System Overview ......................................................................7
Unlimited Measurements with... .............................................8
... more Channels .................................................................8
... more Software..................................................................8
... more Interfaces ................................................................9
... more Performance ...........................................................9
... more Insights ....................................................................9
TRION™ MEASUREMENT SYSTEMS
TRION™ Modules ......................................................................10
TRION™ All-in-One ...................................................................11
TRION™ Mainframes ................................................................12
TRION™ Front-ends .................................................................14
with Fibre-optic & PCIe Interface .......................................14
TRION™ Front-ends .................................................................16
with USB & Ethernet Interface ..........................................16
CAN & RS485 MODULES
CPAD3 ........................................................................................26
EPAD2 / CPAD2 ........................................................................27
ORION MEASUREMENT SYSTEMS
ORION A/D Boards ...................................................................17
Dynamic Amplifiers ...................................................................18
High-speed Amplifiers ..............................................................20
MSI Adapter...............................................................................21
SOFTWARE
PNA Software............................................................................31
OXYGEN .....................................................................................32
Power Analysis with OXYGEN.................................................34
LabVIEW™ Library ....................................................................35
DASYLab Drivers .......................................................................36
DEWETRON OEM .....................................................................37
ORION All-in-One .....................................................................22
ORION Mainframes...................................................................23
ORION Front-ends ....................................................................24
with PCIe Interface ..............................................................24
ORION Front-ends ....................................................................25
with USB & Ethernet Interface ..........................................25
CUSTOMIZED
MODULAR
TURNKEY SYSTEMS
CVT Logger.................................................................................28
Power Analyzer .........................................................................29
Power Quality Analyzer ............................................................30
Accessories ................................................................................38
Solutions ....................................................................................39
COMPETENT
COMMITTED
APPROVED
5
DEWETRON
INSTRUMENT
FAMILIES
DEWETRON data acquisition systems are
categorized into two families, the DEWE2
(TRION™) and the DEWE (ORION) series.
All systems of both series can record vastly
different signal sources in perfect sync. The
analog input modules are leading technology
and guarantee precise and robust results while
offering the right input for almost any sensor.
Sensor
Flexible
connector
panel
Signal
conditioning
Filtering
A/D
conversion
High-speed data
transfer
& synchronization
DEWE2 SERIES WITH
TRION™ MODULES
DATA ACQUISITION MODULES
HOUSING AND STORAGE
Counter
CAN bus
Analog signal conditioning
& A/D conversion
USER EXCHANGEABLE TRION™ MODULES
>> Highest precision
>> Highest channel density
WIDE RANGE OF HOUSINGS
>> Most rugged
>> Fully modular: user exchangeable modules for analog, digital, counter, CAN
DEWE SERIES WITH
ORION CARDS & DAQ MODULES
SIGNAL CONDITIONING MODULES HOUSING AND STORAGE AND A/D CARDS
Analog signal
conditioning
A/D CONVERSION
COUNTER
CAN BUS
ANALOG DAQ MODULES
>> Isolated or differential analog inputs
>> A/D resolution 16 or 24 bit
6
WIDE RANGE OF HOUSINGS
>> Separated A/D card for flexible sampling rates up to 10 MS/s
DEWE-ORION
A/D CARDS
SHORT FORM CATALOG
SYSTEM
OVERVIEW
Signal Conditioning Amplifier
A/D Conversion
Computer inside
Display
ALL-IN-ONE
IN
ADC OUT
>> Built-in display
>> Most compact and flexible configuration
>> Powerful PC inside for fast online displays and analysis
>> Most convenient for mobile applications
MAINFRAME
IN
ADC OUT
>> Powerful PC inside for fast online displays and analysis
>> Can be used with external display
>> Very popular for applications where the instrument is
installed in a poorly accessible place for the user
FRONT-END
IN
ADC OUT
>> High-speed data transfer
>> To be used with an external computer
>> Expansion for All-in-one or Mainframe instruments
>> Multiple units can be daisy-chained
SIGNAL CONDITIONING
>> Stand-alone signal conditioning
>> Front-ends for existing recorders, A/D boards …
>> Channel expansion for DEWETRON instruments
7
DEWETRON
UNLIMITED MEASUREMENTS WITH...
... MORE CHANNELS
HIGH-SPEED
EXPANSION
DEWE2-F7s
Add one or more Frontend chassis
for high-speed expansion
TRION-SYNC-bus
PCIe connection up to 7 meters
LOW-SPEED
EXPANSION
100 HZ
CPAD3 modules with
CAN interface
QUASI-STATIC
EXPANSION
12 HZ
Add one or more EPAD2
modules at any time
... MORE SOFTWARE
OXYGEN
8
DEWE2-F4s
SHORT FORM CATALOG
... MORE INTERFACES
ANALOG INPUTS
DIGITAL INPUTS
COUNTER
VIDEO
ARINC-429, MIL-STD-1553
GPS, VGPS, ABSOLUTE TIMING
z
y
x
INERTIAL DATA
CAN
PCM TELEMETRY
FLEXRAY
XCP
250
250
162,5
162,5
Rec
10 MS/s sampling rate
1 MS/s sampling rate
-12,5
]
U1_1MS; - [V
75
U1_10MS; - [V
]
75
-12,5
-100
50 MB/s
SYSTEM B
100 MB/s
SYSTEM A
150 MB/s
SYSTEM C
200 MB/s
-100
305 MB/s
DEWE-2600-STREAM
... MORE PERFORMANCE
... MORE INSIGHTS
HIGH-SPEED CAM
GIGE CAM
INFRARED CAM
USB CAM
9
DEWETRON
TRION™
MODULES
V
1000
> User exchangeable modules for signal conditioning
> Simultaneous sampling for DEWE2 product series
> Separate ADC on each channel
Voltage
(1000 V)
GPS
Current
(shunt required)
RTD
FlexRay
Current
(with shunt inside)
Absolute Time
ARINC 429
IEPE
(vibration)
Counter Inputs
MIL-STD 1553
Bridge
(strain gage)
CAN
Analog Output
Potentiometer
Modular Smart Interfaces
(e.g. for thermocouple)
Digital I/O
CHANNELS
SAMPLE RATE
PER CH.
RESOLUTION
ISOLATION
CONNECTOR TYPES
4 or 8
204.8 kS/s
24 bit
yes
DSUB, LEMO 0B
V
6
2 MS/s
1 MS/s
16 bit
24 bit
yes
BNC
V
6
2 MS/s
1 MS/s
16 bit
24 bit
yes
BNC, LEMO 1B
V
4 or 8
204.8 kS/s
24 bit
yes
Safety banana sockets
V
6
250 kS/s
16 bit
yes
BNC, LEMO 1B
6 or 8
204.8 kS/s
24 bit
-
RJ-45, DSUB,
LEMO 1B, LEMO 0B
6 or 8
204.8 kS/s
24 bit
-
SMB, BNC
CHANNELS
SAMPLE RATE
PER CHANNEL
RESOLUTION
ISOLATION
INPUT TYPES
ANALOG MODULES
V
100
TRION-2402-MULTI
TRION-1620-ACC
TRION-1620-LV
TRION-2402-V
TRION-1603-LV
100
100
1000
100
V
10
TRION-2402-dSTG
V
TRION-2402-dACC
100
MULTI-FUNCTION MODULES
TRION-1802-dLV
V
10
16 or 32
200 kS/s
100 kS/s
18 bit
24 bit
-
DSUB
TRION-1600-dLV
V
10
16 or 32
20 kS/s
16 bit
-
DSUB
CHANNELS
SAMPLE RATE
PER CHANNEL
RESOLUTION
ISOLATION
INPUT TYPES
6 to 18
800 kS/s
80 MHz
yes
DI, CNT
TRION-DI-48
48
2 MS/s
-
yes
DI
TRION-BASE
1 to 8
2 MS/s
80 MHz
-
DIO, CNT, SYNC, AUX
TRION-VGPS
1 GPS
100 Hz
0.01 km/h
<10 cm
-
GPS antenna, IRIG In / Out, DIO,
CNT, SYNC, AUX
TRION-TIMING
1 to 8
2 MS/s
80 MHz
-
GPS antenna, IRIG In / Out, DIO,
CNT, SYNC, AUX
CHANNELS
SAMPLE RATE
PER CHANNEL
RESOLUTION
ISOLATION
CONNECTOR TYPES
2 or 4
-
-
yes
DSUB
TRION-FLEXRAY
1
-
-
-
DSUB
TRION-A429 /
TRION-M1553 /
TRION-MA4
4 to 30
1 to 4
9 to 13
-
-
-
SCSI-3
Update rate
max. 2.8 MS/s
1 MS/s
16 bit
-
BNC
8 (4 U / 4 I)
2 MS/s
≥ 18 bit
yes
Safety banana, DSUB
DIGITAL MODULES
TRION-CNT
DEDICATED MODULES
TRION-CAN
TRION-1628-AO-2
TRION-1820-POWER
10
V
1000
00101001010001
SHORT FORM CATALOG
TRION™
ALL-IN-ONE
>
>
>
>
Built-in display
Most compact and flexible configuration
Powerful PC inside for fast online displays and analysis
Most convenient for mobile applications
DEWE2-A4
DEWE2-A4L
DEWE2-A7 / DEWE2-A13
DEWE2-A8-STREAM
4
4
7 / 13
8
Slots for TRION™ acquisition
modules
High-speed channel expansion
Add Front-end chassis or setup network
n/a
Low-speed channel expansion
100 Hz
CPAD3 via TRION-CAN
Quasi-static channel expansion
EPAD2
Data storage
256 GB
removable Solid State Disk
1 TB hard disk dedicated for data storage
120 GB SSD for operating system and application software
Optional data storage
500 GB SSD dedicated for
data storage
120 GB SSD for operating system
and application software
Up to 1 TB SSD
Gap free storing rate
Typ. 80 MB/s
Typ. 80 MB/s
Display
13“
(1280 x 800)
15.4“ multi-touch wide-screen
display (1280 x 800)
Typ. 90 MB/s
17“
(1920 x 1080)
FULL HD
Typ. 180 MB/s
17“
(1920 x 1080)
FULL HD
Power supply
Input voltage (max.)
10 to 36 VDC isolated
incl. external AC power supply
90 to 264 VAC
Option 1
Internal buffer battery
for ~ 5 min. operation
-
DC power supply (DW2-PS-DC-300)
10 to 36 VDC
Option 2
(DW2-UPS-250-DC)
Ext. battery pack,
3 battery slots for ~2 hours
operation
-
(DW2-PS-BAT)
Battery powered, 4 battery slots
for ~2 hours operation
318 x 253 x 128 mm
(12.5 x 10 x 5 in.)
462 x 320 x 135
(18.2 x 12.6 x 5.3 in.)
450 x 246 x 303 mm
(17.7 x 9.7 x 11.9 in.)
450 x 246 x 303 mm
(17.7 x 9.7 x 11.9 in.)
Typ. 5.9 kg (13 lb.)
Typ. 8.5 kg (18.7 lb.)
Typ. 15 kg (33 lb.)
Typ. 14 kg (31 lb.)
Dimensions
Dimensions (W x D x H)
(without handle)
Weight without modules and
batteries 1)
Weight of one battery: 660 g (1.45 lb.)
DEWE-CAM-01
Add video data to your measurements via
high shock and vibration resistant camera
DW2-UPS-250-DC,
250 W UPS with 3 battery slots
DW2-A13-CC
Shipping/carrying case
11
DEWETRON
TRION™
MAINFRAMES
> Most compact and flexible configuration
> Powerful PC inside for fast online displays and analysis
> Convinient for mobile applications
Slots for TRION™ acquisition modules
High-speed channel expansion
DEWE2-M4
DEWE2-M4s
4
4
7
n/a
Add Front-end chassis or
setup network
Add Front-end chassis or
setup network
Low-speed channel expansion 100 Hz
CPAD3 via TRION-CAN
Quasi-static channel expansion
Data storage
DEWE2-M7s
EPAD2 or CPAD2 via TRION-CAN
256 GB removable Solid State Disk
Optional data storage
256 GB Solid State Disk
Up to 1 TB
Power supply
Standard (max.)
10 to 36 VDC isolated; incl. external AC power supply
(DW2-PS-DC-Buffer)
Internal buffer battery for ~ 5 min. operation
Option 1
Option 2
(DW2-UPS-250-DC)
Ext. battery pack, 2 battery slots
n/a
(DEWE-UPS-300-DC)
Ext. battery pack, 4 battery slots
318 x 253 x 108 mm
(12.5 x 10 x 4.3 in.)
177 x 230 x 177 mm (4 u)
(7 x .9.1 x 7 in.)
258 x 230 x 177 mm (4 u)
(10.2 x 9.1 x 7 in.)
Typ. 3.9 kg (8.6 lb.)
Typ. 3.9 kg (8.6 lb.)
Typ. 4.9 kg (10.8 lb.)
Dimensions
Dimensions (W x D x H)
(without handle/feet)
Weight without modules and batteries1)
1)
Weight of one battery: 660 g (1.45 lb.)
CAM-SPLIT-BOX
12
BAT-CHARGER-1
Desktop battery charger
for 1 battery
BAT-CHARGER-4
Desktop battery charger
for 4 batteries
DE-POWERBOX-11
DC power distribution box
SHORT FORM CATALOG
DEWE2-M13s
DEWE2-M7 / DEWE2-M13
DEWE2-M18
13
7 / 13
18
Add Front-end chassis or setup network
Ethernet
CPAD3 via TRION-CAN
EPAD2 or CPAD2 via TRION-CAN
CPAD2 via TRION-CAN
256 GB Solid State Disk
1 TB Hard Disk (plus two 3,5“ bays)
256 GB Solid State Disk
Up to 1 TB
Up to 4 TB
Up to 1 TB
10 to 36 VDC isolated;
incl. external AC power supply
90 to 264 VAC
90 to 264 VAC
Internal buffer battery
for ~ 2 min. operation
Redundant AC power supply
n/a
Battery powered, 4 battery slots
for ~2 hours operation
n/a
n/a
441 x 230 x 177 mm (4 u)
(17.4 x 9.1 x 7 in.)
441 x 427 x 177 mm (4 u)
(17.4 x 16.8 x 7 in.)
Typ. 7.3 kg (16 lb.)
Typ. 13 kg (28.6 lb.)
MOB-DISP-12
External display
DEWE2-M13s with 4 battery slots
DEWE2-M13 with 2 hard disks
(2x option DW2-M13-BAY35-SATA)
13
DEWETRON
TRION™
FRONT-ENDS
WITH FIBRE-OPTIC & PCIE INTERFACE
> Most compact and flexible configuration
> High-end A/D conversion
> Data transmission via PCIe (up to 7 m) or fibre-optic
Slots for TRION™ acquisition modules
DEWE2-F4s
DEWE2-F7s
4
7
High-speed channel expansion
DEWE2-F13s
DEWE2-F13-FIBRE
DEWE2-F18
13
13
18
Firbre-optic
(needs fibre-optic
card in host)
PCIe
Daisy-chain another Front-end chassis
Low-speed channel expansion 100 Hz
CPAD3 via TRION-CAN
Quasi-static channel expansion
CPAD2 via TRION-CAN (no EPAD2)
Interface to host
PCIe
Power supply
Power supply standard (max.)
90 to 264 VAC
Option 1
10 to 36 VDC isolated
10 to 36 VDC isolated
Redundant AC power
supply
Redundant AC power
supply
Redundant AC power
supply
Option 2
Internal buffer battery
for ~ 5 min. operation
(requires DC option)
Internal buffer battery
for ~ 5 min. operation
(requires DC option)
10 to 36 VDC isolated;
Internal buffer battery
for ~ 2 min. operation
n/a
n/a
Option 3
n/a
n/a
Battery powered,
4 battery slots1)
for ~2 hours operation
n/a
n/a
Dimensions (W x D x H)
(without feet)
177 x 230 x 177mm
(4 u)
(7 x 9.1 x 7 in.)
258 x 230 x 177 mm
(4 u)
(10.2 x 9.1 x 7 in.)
441 x 230 x 177 mm
(4 u)
(17.4 x 9.1 x 7 in.)
441 x 427 x 177 mm
(4 u)
(17.4 x 16.8 x 7 in.)
441 x 427 x 177 mm
(4 u)
(17.4 x 16.8 x 7 in.)
Weight without modules and batteries1)
Typ. 3.9 kg (8.6 lb.)
Typ. 4.9 kg (10.8 lb.)
Typ. 8 kg (17.6 lb.)
Typ. 12 kg (26.4 lb.)
Typ. 12 kg (26.4 lb.)
Dimensions
1)
Weight of one battery: 660 g (1.45 lb.)
Link and Sync interfaces of A-series
for F-series expansion
14
DEWE-DCDC-24-400-ISO
External DC/DC converter
DEWE2-F13s with redundant 90 to 264 VAC
power supply (option DW2-PS-AC-RED)
SHORT FORM CATALOG
DISTRIBUTED SYSTEMS
OVER LARGE DISTANCE
Example: DEWE2-M13 expanded with
DEWE2-F13-FIBRE via fibre-cable for
long distance
100 m Fibre link for data transfer
IRIG-SYNC
DEWE2-M13
with TRION-TIMING module
DEWE2-F13-FIBRE with
TRION-TIMING module
NETWORK WITH MULTIPLE
SYSTEMS
WiFi
DEWE2-A4
with TRION-BASE module
DEWE2-M7s
with TRION-BASE module
Sync up to 1000 meters (IRIG DC, cable length delay compensation)
GPS-SYNC
DEWE2-A4 with TRION-VGPS
or TRION-TIMING module
DEWE2-M7s with TRION-VGPS
or TRION-TIMING module
GPS
Two or more instruments
synchronized via GPS
15
DEWETRON
TRION™
FRONT-ENDS
WITH USB & ETHERNET INTERFACE
>
>
>
>
Gigabit LAN and USB3
Distributable / stackable
Up to 100 m distance between the TRIONet systems
Touch display
TRIONet
Slots for TRION™ modules
2
1)
Quasi-static channel expansion
CPAD via TRION-CAN or TRION-MULTI (no EPAD)
LAN
2 x 10/100/1000BASE-TX Gigabit Ethernet
LAN configuration
DHCP or Static IP
USB
USB 2.0; USB 3.0
Synchronization
TRION-SYNC-Bus up to 100 m between nodes
System bandwidth
90 MB/s with one connected TRIONet (up to 50 MB/s with more than one)
Display
Status display with touch-screen
Cooling
2 temperature controlled ultra silent fans
Host system requirements
Supported operating systems
Windows 7; Windows 10
Supported interfaces
USB 3.0; USB 2.0; 10/100/1000BASE-TX Gigabit Ethernet
Power requirements
Isolated power supply (max)
10 to 32 VDC (9 to 36 VDC)
Power consumption
Without modules 15 W, totally equipped max. 55 W
External power supply (included)
100 to 240 V ~50 to 60 Hz / 65 W
Dimensions
Dimensions (W x D x H)
320 x 205 x 55 mm (12.6 x 8 x 2.2 in.)
Weight
Typ. 1.9 kg (4.2 lb.) without modules
Environmental specifications
Operating temperature
-20 °C to +60 °C (with pre-warmed unit)
Storage temperature
-20 to +70 °C
Humidity
10 to 90 % non cond., 5 to 95 % rel. humidity
Max. altitude
3000 m (9840 ft)
Sine vibration (EN 60068-2-6)
20 m/s²
Shock (EN 60028-2-27)
30 g
Random vibration (EN 60721-3-2)
Class 2M3
1) unsupported modules: TRION-FLEXRAY; TRION-A429; TRION-M1553; TRION-MA4; TRION-1628-AO-2
LOW CHANNEL COUNT
APPLICATION
LAN
or USB
16
DISTRIBUTED
INSTALLATION
LAN
or USB
LAN & Sync
100 m
SHORT FORM CATALOG
ORION
A/D BOARDS
> Simultaneous sampling with separate A/D converter per channel
> Clock output for synchronizing external devices, e.g. cameras
> Synchronized analog, digital, counter and CAN inputs
ANALOG
INPUT
CHANNELS
INPUT RANGES
RESOLUTION
MAX.
SAMPLING
RATE /
CHANNEL
TYPE OF
ADC
DIGITAL
INPUT
CHANNELS
DIGITAL I/O
COUNTER /
ENCODER
CAN
DEWE-ORION-0824-20x
series
8
Voltage: ±0.1 V, ±0.5
V, ±2 V, ±10 V
IEPE®: 4 mA / 8 mA
excitation
24 bit
204.8 kS/s
delta-sigma
with antialising
filter
up to 40
8
up to 10
(advanced)
up to 2
DEWE-ORION-0816-100x
series
8
Voltage: ±1.25 V,
±2.5 V, ±5 V, ±10 V
16 bit
1 MS/s
up to 40
8
up to 10
up to 2
DEWE-ORION-0816-5Mx
series
8
Voltage: ±5 V
16 bit
5 MS/s
up to 8
8
2
(advanced)
up to 2
DEWE-ORION-0816-10Mx
series
8
Voltage: ±5 V
16 bit
10 MS/s
up to 8
8
2
(advanced)
up to 2
DEWE-ORION-1624-20x
series
16
Voltage: ±10 V
24 bit
204.8 kS/s
up to 40
8
up to 10
(advanced)
up to 2
DEWE-ORION-1616-10x
series
16
Voltage: ±1.25 V,
±2.5 V, ±5 V, ±10 V
16 bit
100 kS/s
up to 40
8
up to 10
up to 2
DEWE-ORION-1616-100x
series
16
Voltage: ±1.25 V,
±2.5 V, ±5 V, ±10 V
16 bit
1 MS/s
up to 40
8
up to 10
up to 2
DEWE-ORION-3216-10x
series
32
Voltage: ±1.25 V,
±2.5 V, ±5 V, ±10 V
16 bit
100 kS/s
up to 24
8
2
up to 2
ORION MODEL
successive
approximation
(SAR)
successive
approximation
(SAR)
successive
approximation
(SAR)
delta-sigma
with antialising
filter
successive
approximation
(SAR)
successive
approximation
(SAR)
successive
approximation
(SAR)
DEWE INSTRUMENTS WITH
ORION A/D BOARDS + DAQ MODULES
SIGNAL CONDITIONING MODULES
ANALOG
SIGNAL
CONDITIONING
ANALOG DAQ MODULES
HOUSING AND STORAGE AND A/D CARDS
A/D conversion
Counter
CAN bus
DEWE-ORION
A/D CARDS
> Isolated or differential analog
inputs
> A/D resolution 16 or 24 bit
> Separated A/D card for flexible
sampling rates up to 10 MS/s
WIDE RANGE OF HOUSINGS
17
DEWETRON
DYNAMIC
AMPLIFIERS
>
>
>
>
Isolated dynamic single channel modules
Isolation up to 1.8 kVRMS
Bandwidth up to 300 kHz
Configuration via RS-485 interface
MODULE
Universal measurement
DAQP-STG
V
MSI
MSI
V
INPUT TYPE
Voltage
Bridge
Capacity
Current
Inductive sensors
Frequency
IEPE
Potentiometer
Charge
Thermocouple
RANGES
Strain gauge, bridge sensors
±0.1 to ±1000 mV/V (@ 5 VDCexc)
Piezoresistive bridge
±0.5 to 10000 mV/mA (@ 1 mAexc)
Voltage
±500 µV to ±10 V
Resistance
25 mΩ to 100 kΩ
Pt100, Pt200, Pt500, Pt1000,
-200° C to 850° C
Pt2000
MSI
DAQP-MULTI
V
High voltage measurement
DAQP-HV
IEPE® via MSI-BR-ACC
±100 to ±10000 mV
Thermocouple via MSI-BR-TH-x
full range of TC type
Charge via MSI-BR-CH-50
up to 50000 pC
Voltage via MSI-BR-V-200
up to ±200 V
Thermoresistor
Pt100, Pt200, Pt500, Pt1000 and
Pt2000, free programmable range
Thermocouple
Type K, J, T, R, S, N, E, B, L, C, U
free programmable range
Resistance
1 Ohm to 1 MOhm
Piezoresistive bridge
Voltage
Current (with external shunt)
13 ranges (±0.5 to 5000 mV/mA)
10 ranges from ±5 mV to ±5 V
depending on external shunt
High voltage
±20 to ±1400 V
V
TEDS
OUT
Current
output
BANDWIDTH (BW),
FILTERS
(LP = LOWPASS,
HP = HIGHPASS)
ISOLATION (ISO),
OVERVOLTAGE
PROTECTION (OP)

BW: 300 kHz
LP: 10 Hz to 300 kHz
ISO: 350 VDC
OP: ±50 VDC

BW: 3 kHz
LP: 3, 10, 30, 100, 300,
1000 Hz
ISO: 1 kVRMS
-
BW: 300 kHz
LP: 10 Hz to 300 kHz
ISO: 1.8 kVRMS

BW: 300 kHz
LP: 10 Hz to 300 kHz
ISO: up to
1 kVRMS
OP: 350 VDC
-
-
Voltage & current measurement
DAQP-LV
Voltage
V
MSI
MSI
MSI
±10 mV to ±50 V
Current (with external shunt)
20 mA / 5 A
IEPE® via MSI-V-ACC
±10 mV to 10 V
Pt100, Pt200, Pt500, Pt1000,
-200° C to 1000° C and
Pt2000 and resistance via
0 to 6.5 kOhm
MSI-V-RTD
Charge via MSI-V-CH-50
up to 50000 pC
Voltage
±10 V (1:1 input)
DAQN-AIN
V
18
OP: < ±500 V
(jumper
selectable)
SHORT FORM CATALOG
MODULE
INPUT TYPE
RANGES
TEDS
-
BANDWIDTH (BW),
FILTERS
(LP = LOWPASS,
HP = HIGHPASS)
ISOLATION (ISO),
OVERVOLTAGE
PROTECTION (OP)
Current measurement
DAQP-LA-SC
DAQP-LA-B
Current
0.1 A to 30 APEAK
Note: 5 ARMS continuous
max. 5 ARMS contin. current
Current
2 mA to 600 mA
BW: 300 kHz
ISO: 1.4 kVRMS
LP: 10 Hz to 300 kHz
-
Note: typ. 20 mA application
BW: 300 kHz
ISO: 1.4 kVRMS
LP: 10 Hz to 300 kHz
Carrier frequency amplifier
DAQP-CFB2
AC bridge, strain gauge
Bridge: 0.1 to 1000 mV/V
-
Note: programable sine wave
excitation up to 20 kHz
BW: DC to 9.6 kHz
OP: ±10 VDC
LP: 10 Hz to 1 kHz
Inductive sensors, LVDT capacity
Inductive: 5 to 1000 mV/V
Capacity
20 pF to 1 µF
IEPE® sensors
±50 mV to ±5 V
Charge / IEPE® measurement
DAQP-ACC-A
-
BW: 0.5 Hz to 300 kHz
-
LP: 1 to 300 kHz
HP: 0.5 Hz and 5 Hz
DAQP-CHARGE-A
Charge sensors
Charge: 5 to 50000 pC
IEPE® sensors
IEPE®: ±5 mV to 5 V
-
Charge sensors
-
LP: 100 Hz to 50 kHz
HP: 0.1 Hz to 10 Hz
Note: selectable integration and
double integration
DAQP-CHARGE-B
BW: 0.1 Hz to 50 kHz
±100 to ±1 000 000 pC
-
BW: DC to 100 kHz
ISO: 350 VDC
LP: 10 Hz to 100 kHz
Note: selectable time constant
for static sensors
HP: DC, 0.001 Hz to
0.5 Hz
Temperature measurement
DAQP-THERM
Thermocouple
Type K, J, T, R, S, N, E, B, L, C and
U selectable
Note: internal CJC and
linearisation
free programmable range
Frequency
100 Hz to 200 kHz
BW: 3 kHz
LP: 3, 10, 30, 100, 300,
1000 Hz
ISO: 1 kVRMS
Frequency measurement
DAQP-FREQ-A
-
BW: according to range
ISO: 350 VDC
Output response:
1.5 ms
30 ms
500 ms
Voltage output module
DAQN-V-OUT
Voltage output
1:1 output module with isolation
-
BW: 400 Hz
ISO: 240 VDC
Input voltage: ±10 V
Output voltage: ±10 V
OUT
19
DEWETRON
HIGH-SPEED
AMPLIFIERS
>
>
>
>
Isolated single channel module
High bandwidth up to 2 MHz
Selectable filters and multiple ranges
Analog signal output (±5 V)
MODULE
Universal measurement
HSI-STG
V
MSI
MSI
INPUT TYPE
RANGES
Strain gauge, bridge sensors
±0.1 to ±1000 mV/V (@ 5 VDCexc)
Piezoresistive bridge
±0.5 to 10000 mV/mA (@ 1 mAexc)
Voltage
±500 µV to ±10 V
Resistance
25 mΩ to 100 kΩ
Pt100, Pt200, Pt500, Pt1000,
-200° C to 850° C
Pt2000
MSI
IEPE® via MSI-BR-ACC
±100 to ±10000 mV
Thermocouple via MSI-BR-TH-x
Full range of TC type
Charge via MSI-BR-CH-50
Up to 50000 pC
Voltage via MSI-BR-V-200
Up to ±200 V
High voltage
±20 to ±1400 V
Voltage
±10 mV to ±50 V
BANDWIDTH (BW),
TEDS FILTERS (LP = LOWPASS,
HP = HIGHPASS)
ISOLATION (ISO),
OVERVOLTAGE
PROTECTION (OP)

BW: up to 2 MHz
LP: 100 Hz to 2 MHz
HP: 1 Hz
ISO: 350 VDC
OP: ±50 VDC
-
BW: 2 MHz
LP: 100 Hz to 2 MHz
ISO: 1.8 kVRMS

BW: 2 MHz
LP: 100 Hz to 2 MHz
ISO: up to
1 kVRMS
OP: 350 VDC
High voltage measurement
HSI-HV
V
Voltage & current measurement
HSI-LV
V
MSI
20
MSI
Current with external shunt
20 mA / 5 A
IEPE® via MSI-V-ACC
±10 mV to 5 V
Pt100, Pt200, Pt500, Pt1000,
-200° C to 1000° C and
Pt2000 and resistance via
8 to 4 kΩ
MSI-V-RTD
SHORT FORM CATALOG
MSI
ADAPTER
>
>
>
>
Modular Smart Interfaces
Expand functionality of bridge and voltage inputs
Automatically detected
Versions for voltage, thermocouple, RTD, IEPE®
and charge sensors
MODULAR SMART INTERFACES FOR HSI, DAQP AND MDAQ MODULES
MSI-BR-ACC
MDAQ-SUB-STG-D
MDAQ-SUB-V-200-D
DAQP-STG-D
DAQP-LV-D
HSI-LV
�
-
�
-
-
Isotron (constant current powered) adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector
Bandwidth and ranges are defined by connected amplifier
Automatic adapter identification
MSI-BR-V-200
�
-
�
-
-
200 V input adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
Differential input configuration, BNC connector
Bandwidth and ranges are defined by connected amplifier
Automatic adapter identification
MSI-BR-RTD
�
-
not needed
-
-
Pt100, Pt200, Pt500, Pt1000 and Pt2000 adapter for MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
2, 3 and 4 wire connection methods, 5-pin Binder 712 series connector
Automatic adapter identification
MSI-BR-CH-x
�
-
�
-
-
Charge input interface for DAQP-STG and MDAQ-SUB-BRIDGE / -STG with DB9 connector
Range up to 50000 pC, AC coupled with 0.07 Hz, BNC signal connection
Max. 100 kHz bandwidth (dependent on the max. bandwidth of the amplifier)
Automatic adapter identification
MSI-BR-TH-x
�
-
�
isolated TC sensor
-
-
any TC sensor
Thermocouple type K / J / T adapter for DAQP-BRIDGE-x and MDAQ-SUB-BRIDGE / -STG modules with DB9 connector
For use with isolated thermocouple sensors only!
High accuracy cold junction reference measurement, 1 m thermo cable with Mini TC connector
Automatic adapter identification
MSI-V-ACC
-
�
-
�
�
Isotron (constant current powered) adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector
Excitation current 4 mA at 21 V, High pass filter 1.5 Hz, BNC connector
Bandwidth and ranges are defined by connected amplifier
Automatic adapter identification
MSI-V-RTD
-
�
-
�
�
Pt100, Pt200, Pt500 and Pt1000 adapter for DAQP-LV and MDAQ-SUB-V-200 modules with DB9 connector
2, 3 and 4 wire connection methods, 5-pin Binder 712 series connector
Automatic adapter identification
21
DEWETRON
ORION
ALL-IN-ONE
>> Built-in display
>> Powerful PC inside for fast online data
view and analysis
>> Convenient for mobile applications
DEWE-2600
DEWE-5000
DEWE-3300
DAQ / PAD amplifier slots
16
16
16
Total PCI slots
7
5
2
4
5
1
Available with DAQ / PAD slots
High-speed channel expansion
DEWE-50-PCI Front-end or DEWE-30
Low-speed channel expansion 100 Hz
CPAD3, requires CAN interface in base unit
Quasi-static channel expansion
EPAD2
Data storage
Optional data storage
Display
1 TB hard disk
120 SSD, 1 TB Daten
Up to 4 TB HDD / Up to 1 TB SSD
15“
(1280 x 800)
17“
(1920 x 1080)
Up to 1 TB SSD
FULL HD
15.6“ multitouch-screen
(1920 x 1080) FULL HD
Power supply
Standard rated (max.)
Option
90 to 264 VAC
90 to 264 VAC
Battery powered, 3 battery slots for ~2 hours operation
90 to 264 VAC
9 to 30 VDC
incl. external AC power supply
Dimensions
Dimensions (W x D x H)
Weight without batteries1)
417 x 246 x 303 mm
(16.4 x 9.6 x 11.9 in.)
460 x 351 x 192 mm
(18.1 x 13.8 x 7.7 in.)
462 x 320 x 135 mm
(18.2 x 12.6 x 5.3 in.)
Typ. 14 kg (31 lb.)
Typ. 17 kg (37.4 lb.)
Typ. 8.2 kg (18 lb.)
1) Weight of one battery: 660 g (1.45 lb.)
2600-CC
DEWE-2600 shipping
and carrying case
22
DEWE-5000 with batteries
(5000-PS-BAT)
2600-CSMK1
Car seat mounting kit for DEWE-2600
SHORT FORM CATALOG
ORION
MAINFRAME
> Portable and rack-mount versions
> Powerful PC inside for fast online data
view and analysis
> Many power supply options
DEWE-800
DAQ / PAD amplifier slots
16
Total PCI slots
5
Available with DAQ / PAD slots
High-speed channel expansion
Low-speed channel expansion 100 Hz
Quasi-static channel expansion
5
DEWE-50-PCI Front-end or DEWE-30
CPAD3, requires CAN interface in base unit
EPAD interface with up to 16 EPAD2 modules = 128 ch
Data storage
1 TB hard disk
Optional data storage
Up to 4 TB hard disk / Up to 1 TB SSD
Power supply
Standard (max.)
90 to 264 VAC
Option
9 to 18 VDC
or
18 to 36 VDC
Dimensions
437 x 443 x 181 mm (4u)
(17.2 x 17.4 x 7.1 in.)
Dimensions (W x D x H)
Weight without batteries1)
Typ. 12 kg (26.4 lb.)
1) Weight of one battery: 660 g (1.45 lb.)
800-MK
DEWE-800 with 19” mounting kit
POWERBOX-11
Power distribution for automotive applications
DEWE-DCDC-24-400-ISO
10 to 36 VDC power supply 24 VDC (400 W)
23
DEWETRON
ORION
FRONT-ENDS
WITH PCIE INTERFACE
> High-speed PCIe connection to your
computer or laptop
> Up to 128 ch per chassis
> Cascading option for creating high
channel count systems
Slots for DAQ or PAD modules
DEWE-50-PCI-32
DEWE-50-PCI-64
32
64
External quasi-static channel expansion
EPAD interface, up to 16 EPAD2 modules = 128 ch
Digital I/O, counter, CAN bus
Depending on selected ORION board(s)
Main system
Internal PCI slots
3
Host PC interface
ExpressCard-54, optional PCI, PCI-Express or ExpressCard-34
7
Supported operating systems
Power supply (max.)
Dimensions (W x D x H)
Weight
Microsoft® WINDOWS® 7/10
95 to 260 VAC
95 to 260 VAC
435 x 300 x 223 mm
(17.1 x 11.8 x 8.8 in.)
435 x 300 x 444 mm
(17.1 x 11.8 x 17.5 in.)
Typ. 10 kg (22 Ibs)
Typ. 15 kg (33 Ibs)
Environmental specifications
Operating temperature
Storage temperature
0 to +50 °C
-20 to +70 °C
Humidity
10 to 90 % non cond., 5 to 95 % rel. humidity
Vibration
EN 60068-2-6, EN 60721-3-2 Class 2M2
Shock
EN 60068-2-27
The use of multiple DEWE-50-PCI on a single PC is supported;
ending up in a very flexible multi-channel system
24
SHORT FORM CATALOG
ORION
FRONT-ENDS
WITH USB & ETHERNET INTERFACE
> Easy USB or Ethernet connection to your computer
> Sync option for channel expansion (some models)
> Various power supply options
Slots for DAQ or PAD modules
External quasi-static
channel expansion
DEWE-50-USB2-8
DEWE-50-USB2-16
DEWE-50-NET-16
8
16
16
EPAD interface, up to 8 EPAD2 modules =
64 ch
EPAD interface, up to 16 EPAD2 modules = 128 ch
A/D conversion
Sampling method
Resolution
Sampling rate
Simultanous sampling
Multiplexed sampling
Multiplexed sampling
24 bit
16 bit
16 bit
204.8 kS/s
500 kS/s aggregate
31.25 kS/s per channel
500 kS/s aggregate
2 counters or 6 digital inputs
Optional
5 isolated counters / 16 TTL level DI
2
-
-
9 to 36 VDC
85 to 264 VAC
85 to 264 VAC
Counter and digital inputs
Counters / digital inputs
CAN bus
High-speed CAN bus interfaces
Power supply
Standard (max.)
Main system
Host PC interface
Supported operating systems
Dimensions (W x D x H)
Weight
USB 2
USB 2
100 Mbit Ethernet
Microsoft® WINDOWS® 7/10
Microsoft® WINDOWS® 7/10
Microsoft® WINDOWS® 7/10
230 x 181 x 104 mm
(9.1 x 7.1 x 4.1 in.)
435 x 245x 133 mm (3 u)
(17.1 x 9.6 x 5.2 in.)
435 x 245 x 133 mm (3 u)
(17.1 x 9.6 x 5.2 in.)
Typ. 3 kg (6.6 lbs)
Typ. 5.5 kg (12 Ibs)
Typ. 5.5 kg (12 Ibs)
Environmental specifications
Operating temperature
0 to +50 °C
Storage temperature
-20 to +70 °C
Humidity
10 to 90 % non cond., 5 to 95 % rel. humidity
Vibration
EN 60068-2-6, EN 60721-3-2 class 2M2
Shock
EN 60068-2-27
50-HANDLE
Carrying handle
50-16-DC
Option for DC power supply
USB interface with hot
plug-and-play capabilities
50-16-OUT-5/-10
16 BNCs on the rear for
conditioned signal output
50-16-MK
19“ rack mount kit
25
DEWETRON
CPAD3
MODULES FOR SLOW
MEASUREMENTS
>
>
>
>
100 Hz sampling rate
High isolation 1500 V
ADC per channel
CAN interface
MODULE
INPUT TYPE
INPUT RANGES
ISOLATION
SPECIAL
Dedicated modules
for type J, K, T
Universal module for types K, J, T,
E, R, S, B, N, C, U
According
thermocouple type
1500 VDC (channel to
channel and channel to BUS, power
and chassis)
Overvoltage protection:
15 VDC
8 isolated voltage input channels
Physical input range: ±50 V
Software selectable:
±100 mV, ±500 mV, ±1 V, ±2.5 V,
±5 V, ±10 V
1500 VDC (channel to
channel and channel to BUS, power
and chassis)
Overvoltage protection:
350 VDC
CPAD3-TH8-x
CPAD3-V8
CPAD3-TH8-X
>
>
>
>
Intelligent amplifier with integrated A/D conversion
CAN interface
8 input channels for thermocouples
Available thermocouple types:
> CPAD3-TH8-x: K, J, T standard type
> CPAD3-TH8-UNIVERSAL: K, J, T, E, R, S, B, N, C, U
CPAD3-V8
> Intelligent amplifier with integrated A/D conversion
> CAN interface
> 8 isolated voltage input channels
CPAD3-V8-B
> CAN interface
> 8 isolated voltage input channels
26
SHORT FORM CATALOG
EPAD2 /
CPAD2
>> Extremely rugged and flexible mounting
>> 24 bit A/D converter per channel, 12 Hz sampling rate
>> Channel to channel/system isolation
>> EPAD: RS-485 interface / CPAD: CAN interface
>> Stackable and lockable
MODULE
INPUT TYPE
INPUT RANGES
ISOLATION
SPECIAL
Dedicated modules
for type J, K, T
Universal module for types K, J, T,
E, R, S, B, N, C, U
According
thermocouple type
350 VDC
(channel to channel and channel
to BUS, power and chassis)
Overvoltage protection:
15 VDC
8 isolated voltage
input channels
Physical input range: ±50 V
Software selectable:
±100 mV, ±500 mV, ±1 V, ±2.5 V,
±5 V, ±10 V
350 VDC
(channel to channel and channel
to BUS, power and chassis)
Overvoltage protection:
350 VDC
8 isolated Resistance
Temperature Detector channels
Resistor: 0 to 999.99 Ω
RTD: PT100(385), PT200 (385),
PT500(385), PT1000 (385),
PT2000(385), PT100 (3961)
350 VDC
(channel to channel and channel
to BUS, power and chassis)
Overvoltage protection:
15 VDC
8 isolated current inputs
0 to 20 mA, ±20 mA, ±30 mA
350 VDC
(channel to channel and channel
to BUS, power and chassis)
Overcurrent protection:
70 mA cont.
USB-interface module
for EPAD2
n/a
-
-
OUTPUT TYPE
OUTPUT RANGES
ISOLATION
SPECIAL
4 voltage or current output
channels
±10 V; ±5 V; 0 to 5 V; 0 to 10 V;
0 to 20 mA; 4 to 20 mA
350 VDC
(channel to BUS, power and
chassis)
-
EPAD2/CPAD2-TH8-x
EPAD2/CPAD2-V8
EPAD2/CPAD2-RTD8
EPAD2/CPAD2-LA8
EPAD2-USB
MODULE
EPAD2-AO4
* CPAD = CAN-bus interface
* EPAD = RS-485 interface
27
DEWETRON
CVT
LOGGER
>
>
>
>
USB data logger for current, voltage and temperature inputs
Touch operation and easy to use software
8 channels (expandable to 128 channels)
24 bit, up to 10 Hz
PACKAGES
Each package contains:
CVT Logger software, interface module,
and power supply (24 V).
EPAD modules of your choice must be
selected (bricks of 8 channels). Depending
on application, CVT Logger is delivered
stacked, or separated for distributed
measurements. For distributed systems
cable length between the modules can be
selected (2 m, 5 m, 10 m).
EPAD MODULES
MODULE
INPUT TYPE
INPUT RANGES
ISOLATION
Universal module for types K, J, T, E, R, S,
B, N, C, U
According
thermocouple type
350 VDC
(channel to channel and channel to BUS,
power and chassis)
8 isolated Resistance
Temperature Detector channels
Resistor: 0 to 999.99 Ω
RTD: PT100(385),
PT200 (385), PT500(385), PT1000 (385),
PT2000(385), PT100 (3961)
350 VDC
(channel to channel and channel to BUS,
power and chassis)
8 isolated current inputs
0 to 20 mA, ±20 mA, ±30 mA
0 to 20 mA, ±20 mA, ±30 mA
8 isolated voltage input channels
Physical input range: ±50 V
Software selectable:
±100 mV, ±500 mV, ±1 V, ±2.5 V, ±5 V,
±10 V
350 VDC
(channel to channel and channel to BUS,
power and chassis)
EPAD2-TH8-x
EPAD2-RTD8
EPAD2-LA8
EPAD2-V8
28
SHORT FORM CATALOG
POWER
ANALYZER
> Modular high precision Mixed Signal Power
Analyzer
> Poly-phase power analysis up to 7 phases
> Online calculation of several power groups
> Up to 10 MS/s/ch simultaneous acquisition
> Gapless data acquisition
Slots for TRION™ acquisition modules
High-speed channel expansion
DEWE2-PA7
DEWE2-A4L-PA
7
4
Add one or more TRIONet
CPAD3 via TRION-CAN
EPAD2
CPAD via TRION-CAN or TRION-MULTI
(no EPAD)
1 TB hard disk dedicated for data storage
120 GB SSD for operating system and OXYGEN Measurement Software
-
Up to 1 TB SSD
-
Quasi-static channel expansion
Optional data storage
Gap-free storing rate
Display
2
Add Front-end chassis or setup network
Low-speed channel expansion 100 Hz
Data storage
TRIONet-PA
Typ. 80 MB/s
9’’ multi-touch wide screen
(1280 x 800)
15.4’’ multi-touch wide screen
(1280 x 800)
-
Power supply
Input voltage (max.)
90 to 264 VAC
10 to 32 VDC (9 to 36 VDC)
Dimensions
Dimensions (W x D x H)
(without feet/handle)
Weight without modules and batteries1)
1)
441 x 427 x 177 mm
(4 u plus 1 u for cooling in cabinet required)
(17.4 x 16.8 x 7 in.)
462 x 320 x 135 mm
(18.2 x 12.6 x 5.3 in.)
320 x 205 x55 mm
(12.6 x 8 x 2.2 in.)
Typ. 13kg (28.6 lb.)
Typ. 8.5 kg (18.7 lb.)
Typ. 1.9 kg (4.2 lb.)
Weight of one battery: 660 g (1.45 lb.)
MOTOR
INVERTER
ROTATION SPEED
HARMONIC LOAD
FLICKER
EFFICIENCY
HARMONIC EMISSION
LOAD
TEMPERATURE
TORQUE
ACTIVE POWER
POWER FACTOR
29
DEWETRON
POWER QUALITY
ANALYZER
> Modular and dedicated multi channel
Power Quality Analyzer
> Up to 64 synchronous channels
> All-in-one and rack mounted versions
DAQ / PAD amplifier slots
DEWE-3300-PQA
DEWE-800-PQA
DEWE-571-PQA-4U12I
16
16
-
Fixed amplifiers
-
-
4 x U, 12 x I
Total PCI slots
2
5
1
Available with DAQ / PAD slots
1
5
n/a
High-speed channel expansion
Low speed channel expansion 100 Hz
DEWE-50-PCI Front-end or DEWE-30
CPAD3, requires CAN interface in base unit
Quasi-static channel expansion
Data storage
Optional data storage
Display
n/a
n/a
EPAD2
120 GB, 1 TB HDD
1 TB hard disk
256 GB Solid State Disk
Up to 1 TB SSD
4 TB HDD / 1 TB SSD
Up to 1 TB SSD
15.5’’ multi-touch screen
(1920 x 1080) FULL HD
n/a
12.1” TFT touchscreen
95 to 260 VAC
95 to 260 VAC
Battery powered, 2 battery slots,
2 batteries for ~2 hours operation incl.,
incl. external AC power supply
8 to 30 VDC incl. external AC power supply
9 to 18 VDC or 18 to 36 VDC
n/a
462 x 320 x 135 mm
(18.2 x 12.6 x 5.3 in.)
437 x 443 x 181 mm (4 u)
(17.2 x 17.4 x7.1 in.)
360 x 300 x 150 mm
(14.2 x 11.8 x 5.9 in.)
Typ. 8.2 kg (18 lb.)
Typ 12 kg (26.4 lb.)
Typ. 5 kg (11 lb.)
Power supply
Power supply standard rated max.
Power supply option
Dimensions
Dimensions (W x D x H)
Weight without batteries 1)
Weight of one battery: 660 g (1.45 lb.)
30
SHORT FORM CATALOG
PNA
SOFTWARE
FOR POWER
QUALITY ANALYSIS
The PNA data acquisition software is
designed for applications in the lower-,
middle and high voltage grids, for storing
RMS values, power quality parameters
according to standards and recording
transients. The reporting tool PNA Post
is a handy tool for analyzing, displaying, comparing, exporting and reporting
stored data. Data can be analyzed in time
domain, frequency domain, statistical
analysis and special reporting according to
international standards.
PNA-SW-COMPLETE
PNA-SW-POWER-2
PNA-SW-ALARM
This software package includes all PNA
software options (FFT, POWER, …)
Enhanced power: Shows the symmetrical
components, in value and times-graph and
the loop impedance of the grid
Alarm module: Module for setting up
alarms on a PNA data network
PNA-SW-FFT
FFT analysis: Analysis up to 50th harmonic, detection of the direction, Interhamonics, Scope, Vectorscope
PNA-SW-POWER
Power monitor: Visualization of all relevant
data for power as value and graph, min.
/ max., 10 ms half period min / max with
timestamps
PNA-SW-DIST
Disturbance fault recorder module
PNA-SW-EN50160
Analysis of EN 50160 and flicker meter,
statistical evaluation, spectral analysis,
event monitor, CBEMA-(ITIC) curve
PNA-SW-TRANS
Transient recorder: Trigger on U / I / P / cos
Phi / harmonics etc.
PNA-SW-TEL
PNA-SW-REC
Data recorder: 8x U/I/temperature etc.
(without hardware, PNA-PAD-BOX or PAD
modules required)
PNA-SW-NET
Data network connection of the PNA
system, allows remote control,
remote postprocessing, data download
with modem and LAN
Module for detection and analysis of
telegrams
31
DEWETRON
OXYGEN
DATA ACQUISITION &
ANALYSIS SOFTWARE
Measure, store, view and analyze your measurement data with maximum efficiency. The
64-bit technology and unique multi-touch
user interface will inspire you.
EFFICIENCY &
PERFORMANCE
MULTI-TOUCH &
MOUSE
ANALYZE WHILE
RECORDING
> Easy-to-use and intuitive
> Efficient workflow that minimizes the
time between set-up and reporting
> High performance through 64-bit
technology
Get the best of two worlds: Efficient setup
using the mouse and keyboard in the
office or pure multi-touch operation in the
field.
DejaView allows you to view and analyze
all data from the start of the test, while
data is still being recorded – an especially
useful feature for long term testing.
Live View: Live data is still visible at the
same time on a different recorder, on the
same or on a different screen.
Live View
DejaView
MULTIPLE MEASUREMENT
SCREENS
DejaView
Organize your instruments on multiple
screens for a good overview and immediate analysis.
Live View
Look back in time and analyze with DejaView while data is still recorded and displayed in Live View
32
SHORT FORM CATALOG
LOGGING & RECORDING
Freely define your measurement screen(s),
up to hundreds of channels. Keep track on
all your data by using multiple measuring
screens.
Use trigger functions to immediately
capture any anomaly in the data.
Record any input over a long time:
> Voltage, current
> Temperature
> Pressure
> Acceleration
> Strain gauge
> And many more
VIEWING & ANALYZING
Multiple precision measurement systems
and analysis functions increase the value
of your measurements:
>
>
>
>
>
Scope
FFT
Statistic functions
Logic-, trigonometric functions
E-Power calculation (efficiency
measurement)
> XY chart
> And many more
ADVANCED APPLICATIONS
Use GPS/IRIG to synchronize your
distributed measurement systems
(e.g. in two different trains).
>
>
>
>
>
>
IRIG/GPS
DI/DO
Counter
Video (USB and GigE)
CAN
And many more
INDIVIDUAL REPORTING
There are plenty of options how to easily
create your test reports. Stay within
OXYGEN to print reports directly. Use your
common office software tools (e.g. Excel)
or export to common 3rd party analysis
software, like MATLAB.
Popular analysis platforms, like FlexPro
and FAMOS, open OXYGEN files directly.
33
DEWETRON
POWER ANALYSIS
WITH OXYGEN
POWER CALCULATION
FEATURE OF SOFTWARE
OXYGEN
OXYGEN with Power option seamlessly integrates data
being transmitted through multiple, totally synchronized signals into calculations for power analysis.
MULTI POWER ANALYZER
OXYGEN with Power option turns your DEWETRON
system into a MIXED SIGNAL POWER ANALYZER
for the simultaneous calculation of several power
groups with up to 7 phases. Power instruments can be
easily arranged using drag & drop predefined schematics and state-of-the-art multi-touch technology. All
important values for your analysis are clearly displayed
and in the right form.
HARMONIC ANALYSIS
Harmonic analysis at its best! We include all relevant
harmonic/interharmonic and higher frequency parts in
one chart. OXYGEN with Power option makes it easy
to keep the focus on what you are interested in. The
simultaneous display of voltage and current makes
it easy to analyze the behavior of electrical motors,
drives and other electrical components.
TESTBED INTEGRATION
OXYGEN’s smart interface technology makes it easy
to integrate a MIXED SIGNAL POWER ANALYZER
into automation systems and test bed environments.
Smart interface technology guarantees reliable data
transmission, easy to use remote control/configuration
by using TCP/IP based protocols in compliance with
standardized (e.g. ASAM) protocols and file formats.
34
FEATURES OF POWER ANALYSIS SOFTWARE
> Simple power group creation
> Predefined schematics for 1 to 7
phase power groups
> Several power groups with different
frequencies and variable sync sources
> Dedicated power instrument with
overview table, vector scope and
harmonics
> Calculation of flicker and flicker
emission
> Total and fundamental values of
voltage, current and power
> Fundamental frequency support
from 0.2 Hz to 1500 Hz or DC
> Gapless calculation
> Update rate down to 10 ms
SHORT FORM CATALOG
LABVIEW™
LIBRARY
FOR GRAPHICAL
PROGRAMMING
LabVIEW™ is a visual programming platform
that allows engineers and scientists the
flexibility to build programs specific to unique
data acquisition requirements and measurement systems. It offers unprecedented
integration with existing legacy software,
IP, and hardware while capitalizing on the
latest computing technologies. LabVIEW™
provides tools to resolve the challenges of
today and tomorrow. LabVIEW™ software is
ideal for any measurement or control system.
Integrating all the tools that engineers
and scientists need to build a wide range
of applications in dramatically less time,
LabVIEW™ is a development environment
for problem solving, accelerated productivity,
and continuous innovation.
Through the DEWETRON website, we offer
a comprehensive LabVIEW™ driver library
that supports all DEWETRON systems and
components, .
LINUX SUPPORT
DEWETRON TRION™ modules can run
in a Linux environment (CentOS, Ubuntu
and compatible distributions). Like all LabVIEW™ code, the DEWETRON LabVIEW™
libraries are platform independent and can
be used with Linux as well.
SAMPLE VIRTUAL
INSTRUMENTS
To expedite the development process
you use the ready-to-use functions and
example programs.
DEWETRON instruments
Signal conditioning
modules
DEWE-ORION
multifunction A/D boards
TRION™ PXI measurement modules
LOW LEVEL VIRTUAL
INSTRUMENTS
Using low level VIs you can create your own
project from scratch. Use VIs to access every single feature of the multifunction ADC
board, including. but not limited to sample
rate, input ranges, AI channels, digital I/O,
counter, onboard RS-485 interface, and
CAN bus interface.
DEWETRON CONNECTOR
The DEWETRON Connector is an abstraction layer for the DEWETRON hardware.
Use the ready to use GUI for configuring all
DEWETRON inputs and skip programming
at the board level. Programming on the Connector level is as easy as calling functions
like init, start, read, stop and quit. This saves
valuable development time and minimizes
the risk of programming errors.
35
DEWETRON
DASYLAB
DRIVERS
FOR SIGNAL CONDITIONING MODULES
AND ORION-BASED
INSTRUMENTS
DEWETRON offers a complete measurement solution with DASYLab. Drivers
for DAQP and PAD amplifier series are
supported as well as the ORION A/D board
driver with 16-bit . Simultaneously sampled analog inputs, synchronous digital
inputs and counters, and sampling rates
up to 5 MHz ensure performance, stability
and reliability without additional software.
DEWETRON drivers and DASYLab run on
Windows 7 and Windows 10 with 32 and
64-bit.
>> ORION-1616-100 /-500
>> ORION-3216-100
>> ORION-0816-1000 / -5M
>> ORION-1616-1000
>> DAQP series modules
>> PAD/EPAD modules
AD INPUT
The DASYLab driver supports the whole
ORION A/D boards with 16-bit. Also multiple AD cards can be combined to extend
channels. The smart driver architecture
does automatic hardware synchronization
of multiple cards.
CLOCK, TRIGGER AND
CLOCKOUT
The ORION cards also support an external
clock and trigger, which synchronizes to
other clock sources, or to rotary encoders
to transform from time domain to order
domain. Two free programmable clockout
channels, can be used to sync with other
devices.
36
DIGITAL AND COUNTER
INPUTS
The ORION A/D board series with 16-bit
also support synchronous digital and
counter inputs. Digital and counter inputs
are read with the selected sampling rate.
Compared to other AD cards where this is
read asynchronous, this feature enables
that fast digital channels can be measured
with the full sampling rate. The outstanding digital input filter of the ORION
counters will support measurements at
harsh electrical environments.
>> Basic event counting
>> Gated event counting
>> Up down counting
>> Basic encoder
SHORT FORM CATALOG
DEWETRON
OEM
SOFTWARE
DEVELOPMENT KIT
If your prefer to write your own program
code in C, C++, C#, Visual Basic, Python
or Java, our SDK for TRION is available for
you.
The DEWETRON TRION SDK is shipped
with the necessary interface files for C/
C++ (.h -Files) and Pascal-dialects like
Delphi (.pas – Files).
Using these files, direct integration into
the application can be achieved by including them. But this is not the limit, because
many languages are supported indirectly.
All public interface functions use the “stdcall” calling convention.
DATA TYPES
All public interface functions accept the
following primitive data types:
> 32-bit integers and pointers to 32-bit
integers
> 64-bit integers and pointers to 64-bit
integers
> Pointers to zero-terminated ASCIIStrings (no Unicode/wide string
support)
All public interface functions are accessible
by using the standard C. Therefore, any
programming language that allows the
above mentioned perquisites can exploit
the functionality of the API.
DEWE2 EXPLORER
INCLUDED
If you’re using the TRION hardware, the
API will install a DEWE2 Explorer application (delivered standard with all DEWE2
systems). Besides providing in-depth system information, this tool enables users to
run self-tests of TRION modules, enable
logging files in case of errors and to easily
upgrade the firmware of TRION modules.
The explorer can also create a virtual system in addition to the real one, to aid you
in programming your own application even
without the real hardware.
37
DEWETRON
ACCESSORIES
CAMERAS
MOBILE DISPLAY
CARRYING CASES
FireWire and Ethernet cameras;
Split-box for supplying and connecting
Ethernet cameras
External multi-touch display for mobile
applications
Carrying cases and transportation systems
are available for all systems
POWER SUPPLY
SOLUTIONS
CAR SEAT
MOUNTING KITS
CURRENT
TRANSDUCERS
Power supplies, battery and distribution
boxes
Car seat mounting kits for our mobile
systems
Several solutions for current measurement
from simple shunts to current clamps and
high-precision zero flux transducers
SYNCHRONIZED TIME
BASE GENERATOR
GPS SENSORS
ENCODER
GPS based speed and displacement
sensor
Encoders for combustion analysis and
torsional and rotational vibration
applications
The DEWE-CLOCK is a synchronized time
base generator (absolute time) capable of
using either GPS or IRIG as time source
38
SHORT FORM CATALOG
SOLUTIONS
YOUR MEASUREMENT APPLICATION ON OUR PRODUCTS
GENERAL
SOLUTIONS
MIXED SIGNAL RECORDER, DYNAMIC SIGNAL
ANALYZER, BALANCING, STROBE CAM, ORDER TRACKING, MODAL ANALYSIS, TORSIONAL & ROTATIONAL VIBRATION, TRANSIENT
RECORDER, DISTRIBUTED SYSTEMS, AND
MANY MORE
AUTOMOTIVE
COMBUSTION ANALYSIS, HYBRID TESTING,
MEASURING BATTERIES, FUNCTIONAL SAFETY, ROAD LOAD DATA, BASIC BRAKE TEST,
VEHICLE DYNAMICS, ADAPTIVE CRUISE CONTROL, TORSIONAL & ROTATIONAL VIBRATION,
E-MOBILITY, RACE CAR, AND MANY MORE
AEROSPACE
FLIGHT TEST, ENGINE TEST, WIND TUNNEL
TEST, MAINTENANCE, COMPONENT TEST,
SYSTEM INTEGRATION LAB, NOISE AND
VIBRATION, TACTICAL OR LAND VEHICLE,
STRUCTURAL TEST, PCM TELEMETRY, MODAL
TEST, AND MANY MORE
ENERGY & POWER
ANALYSIS
POWER ANALYSIS, 3 TO 7-PHASE SYSTEMS,
TEST BENCH, SOLAR INVERTERS, REAL DRIVE
TEST, E-MOBILITY, FREQUENCY CONVERTER,
POWER QUALITY ANALYSIS, MONITORING,
GRID COMPATIBILITY, POWER CONVERTER
TEST, AND MANY MORE
TRANSPORTATION
NOISE ORIGIN, CURRENT COLLECTOR TEST
ON TRAINS, POWER SUPPLY OF RAILWAY
SYSTEMS, BATTERY MEASUREMENT,
TORSIONAL & ROTATIONAL VIBRATION, DISTRIBUTED MEASUREMENTS, MIXED SIGNAL
RECORDING, AND MANY MORE
39
>
>
>
>
>
05/ 2017
DE-B160101E • All trademarks are acknowledged to be the property of their owners. Specificat io n subject t o chan ge w i t ho ut n o t i ce. Pr i n t ed i n t he USA. © DEW ETRO N Gm b H
CUSTOMER
CARE CENTER
Maintenance
Calibration
Help Desk
Training
Upgrade
DEWETRON Inc., Headquarters USA
2850 South County Trail, Unit 1
East Greenwich, RI 02818, USA
Phone: +1-401-284-3750
E-Mail: [email protected]
Web: www.dewetron.us
GENERAL SOLUTIONS
AUTOMOTIVE
AEROSPACE
ENERGY & POWER ANALYSIS
TRANSPORTATION
ABOUT DEWETRON
DEWETRON is an Austrian manufacturer
of precision Test & Measurement systems
designed to help our customers make the
world more predictable, efficient and safe.
Our strengths lie in customized solutions
that are immediately ready for use while
also being quickly adaptable to the
changing needs of the test environment
and sophisticated technology of the
Energy, Automotive, Transportation and
Aerospace industries. More than 25 years
of experience and innovation have awarded
DEWETRON the trust and respect of the
global market. There are more than 20,000
DEWETRON measurement systems and
over 300,000 measurement channels in
use in well-known companies worldwide.
Choosing DEWETRON means, having a
partner by your side who accompanies you
every step of the way.
DEWETRON employs over 150 people in
25 countries and is part of the TKH Group,
a global corporation, that specializes in
the development and supply of innovative
solutions worldwide. DEWETRON quality is
certified in compliance with ISO9001 and
ISO14001.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement