null  null
New_Intruder_Covers 3:Layout 1 23/08/2010 13:17 Page 1
Intruder Alarms
UK Product Catalogue
A Tyco International Company
IntroContentpgsIntrudrCat:Layout 1 20/03/2012 11:43 Page 1
Introduction
Welcome to the 14th Issue of Tyco EMEA’s Intruder Product Catalogue containing the wide range of products available
from our distribution centre in Letchworth. We aim to make your product range as comprehensive as possible to ensure
you never need go anywhere else. To meet this goal, our product specialists, with your help, have selected the most
appropriate, cost effective product range available on the market.
In line with our ISO 9000 accreditation, only those products that meet the highest quality criteria have been included.
Our goal is to despatch product on the same day as we receive your order. Our warranty and service returns policy is
second to none. We recognise that your business is highly dependent on excellence in customer service and to help
achieve this we offer extended warranty from many of our suppliers. Full credit is also available on a “No Question – No
Fuss” basis for any new in-warranty product returned to the distribution centre. Our standard duration for warranty is a
minimum of 12 months credit.
The Tyco EMEA Web site contains an endless supply of product related
information available in multiple languages - English, Dutch, French,
German, Italian, Polish and Spanish. It is regularly updated and features
many aids to the selling process including presentation material and
detailed technical information.
To enhance customer specifications and quotations we also provide a
series of product datasheets which can give our clients an opportunity to
read more about the product.
We are positive that together we can help grow your business and we
look forward to working with you in the future.
TECHNICAL SUPPORT & PRE-SALES CALL CENTRE
CONTACT INFORMATION
TYCO International EMEA
Voltaweg 20
6101 XK Echt - The Netherlands
Fax: +31 475 352 725
For Technical Services:
Hours: 8:00 to 18:00 EET, CET, GMT:
(Toll Free): +800CALLTYCO OR
+800 2255 8926
UK: 08081 013 73 OR 08701 238 787
For Technical Pre-sales Inquiries:
[email protected]
For Technical Training Enquiries:
[email protected]
http://www.tycoemea.com/English/Training.asp
For SSA/dongle Requests:
http://www.tycoemea.com/Dongle/index.htm
For Technical Post-Sales Enquiries:
[email protected]
www.tycoemea.com
www.calltyco.com
Hours: 8:00 to 18:00 EET, CET, GMT:
(Toll Free): +800CALLTYCO OR +800 2255 8926 UK: 08081 01373 OR 08701 238787
03/12
Intruder Catalogue
i
IntroContentpgsIntrudrCat:Layout 1 20/03/2012 11:43 Page 2
Contents
CONTENTS
Introduction
i
Contents
ii
Introduction of Intruder Alarm to European Standards
iii
Chapter 1 - Accessories
1.1
Chapter 2 - Audio Verification
2.1
Chapter 3 - Batteries
3.1
Chapter 4 - Contacts (Magnetic)
4.1
Chapter 5 - Day Alarms
5.1
Chapter 6 - Detectors - Beam
6.1
Chapter 7 - Detectors - Glassbreak
7.1
Chapter 8 - Detectors - Sequential Confirmation
8.1
Chapter 9 - Detectors - Dualtech
9.1
Chapter 10 - Detectors - Passive Infra-Red
10.1
Chapter 11 - Detectors - Vibration
11.1
Chapter 12 - Detectors - Temperature
12.1
Chapter 13 - External Lighting Control
13.1
Chapter 14 - Life Safety Devices
14.1
Chapter 15 - Intruder Alarm Control Panels - Galaxy
15.1
Chapter 16 - Intruder Alarm Control Panels - Domonial
16.1
Chapter 17 - Le Sucre
17.1
Chapter 18 - Perimeter Protection
18.1
Chapter 19 - Power Supply Units
19.1
Chapter 19 - Radio Equipment - Cooper Security
201
Chapter 21 - Radio Equipment - EMS
21.1
Chapter 22 - Signalling
22.1
Chapter 23 - Sounders
23.1
Chapter 24 - Cable
24.1
ii
Intruder Catalogue
03/12
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 1
Chapter 1 - Accessories
Accessories
Features
1147
• Easy Fit
• Unobtrusive Design
• Sleek Design
1148
609.002.024
1175
1155
DRB002NF
Exit Terminators
Exit terminate buttons are used to provide a final set input to
alarm systems. Generally sited outside the premises,
operation of the exit terminate button is the final action
required in the setting process.
This facility is mandatory in some police authority areas.
Product Codes
1147
1148
1155
1175
609.002.024
DRB002NF
03/12
Intruder Catalogue
Surface mount exit terminate button,
Smith type
Surface mount box for use with 1147 exit
terminate button
Exit terminator switch, magnetic operation
type. White. Requires ferrous object to be
held against it to operate.
ADT key ring for use with magnetic
operation type exit terminator+
Elmdene set switch with white clip on
bezel
ICS S/S Intruder set switch
Chapter 1 Page 1
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 2
Chapter 1 - Accessories
Features
• Silent Operation
• FSL and D/P Connection
• Multiple Control Panel / Resistor Options
• Easy Connection of Multiple Units
• Anti-lock Reset Mechanism
• Independent Micro Switch Tamper (removal of cover
initiates tamper signal only)
• Integral Storage for Rest Key
• Selectable Normally Closed or Open Contacts
New Elmdene PAB’s
A new range of static panic alarm buttons from Elmdene
International that conform to Grade 3 of EN50131-1. The
new range has the benefit of having separate tamper and
alarm contacts, which are necessary for reporting for Grade
3 systems, the tamper being a spring micro switch and the
alarm contacts being a magnetic/reed switch.
All units are Grade 3 Double Push with integral resistors for
use with most control panels or option for Double Pole.
Spare terminals allow through connection for multiple units
wired to one zone.
Special features include integral storage of reset key and
anti-lock reset mechanism to ensure unit still operates if
reset key is left in the unit and silent operation.
Elmdene Panic Buttons fully comply with 'The ACPO 10
Point Plan' and all requirements under EN50131-1:2006 and
PD6662:2004 A1 + A2.
The panic buttons can be wired in fully supervised formats
or traditional without any resistors (no jumpers fitted)
In addition they have clamp down terminals and have
selective resistor value jumpers that can be used for the
following panels;
• 4k7/2k2 ADE, Bosch, Castle, Menvier, Pyronix,
Scantronic, Texecom
• 1k/1k Galaxy
• 8k2/8k2 Guardall
• 4k7/4k7 Aritech
• 6k8/4k7 GardTec
• 2k2/2k2 Europlex
• 5k6/5k6 DSC
• Double Pole (no resistors)
Technical Specification
Product
Code
Dimensions
HxWxD mm
Operating
Temp.
ELM-PA-G3-SS
ELM-PA-G3-B
ELM-PA-G3-W
81 x 63.5 x 29
81 x 63.5 x 29
81 x 63.5 x 29
-40 C to +50 C
o
o
-40 C to +50 C
o
o
-40 C to +50 C
o
o
Action
Magnet Colour
Silent action, latching (key release)
Silent action, latching (key release)
Silent action, latching (key release)
Finish
Ferrite Stainless Steel Stainless Steel
Ferrite
Brass
Brass
Ferrite
White
Plastic
Indication
Flag Indication
Flag Indication
Flag Indication
Product Codes
ELM-PA-G3-B
ELM-PA-G3-SS
ELM-PA-G3-W
ELM-PA-KEY
1146
1183
1184
Chapter 1 Page 2
Intruder Catalogue
Grade 3 Panic Button - Brass
Grade 3 Panic Button - Brushed Stainless
Steel
Grade 3 Panic Button - White
Pack of 5 spare keys for Panic Buttons
Geutebruck suspicion button
Replacement key for Knight Plastics PA
button
Replacement key for Maximal PA buttons
03/12
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 3
Chapter 1 - Accessories
Features
• Compact
• Various Sizes
• Choice of colour
Door Loops
These are used for looping from door frame to a door.
For use with contacted locks, wired and covered doors etc.
Product Codes
EDL1
EDL2
EDL3
EDL1-BN
EDL2-BN
EDL3-BN
EDL1-KIT
EDL2-KIT
EDL3-KIT
EDL1-BN-KIT
EDL2-BN-KIT
EDL3-BN-KIT
03/12
30cm fixed length door loop white
25cm white door loop extendable
up to 170cm
50cm white door loop extendable
up to 330cm
30cm fixed length door loop Brown
25cm Brown door loop extendable
up to 170cm
50cm Brown door loop extendable
up to 330cm
30cm fixed length door loop white
Inc 2 EN3-JB9-HD-W & 2 Grommets
25cm white door loop extendable up
to 170cm Inc 2 EN3-JB9-HD-W & 2
Grommets
50cm white door loop extendable up
to 330cm Inc 2 EN3-JB9-HD-W & 2
Grommets
30cm fixed length door loop Brown
Inc 2 EN3-JB9-HD-W & 2 Grommets
25cm Brown door loop extendable
up to 170cm Inc 2 EN3-JB9-HD-W & 2
Grommets
50cm Brown door loop extendable
up to 330cm Inc 2 EN3-JB9-HD-W & 2
Grommets
EN3-JB9-HD-GROMMET
EN3-JB9-HD-BN-GROMMET
Intruder Catalogue
Pack of 10 white end
Grommets for HDJB’s
Pack of 10 brown end
Grommets for HDJB’s
Chapter 1 Page 3
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 4
Chapter 1 - Accessories
Features
•
•
•
•
•
Real tamper switch with spring operation
Clamp style terminals
Choice of models
Modern design
EN Grade 3 compliant
Junction Boxes
Designed for use in security applications, these junction
boxes are provided with a tamper connection which will
open circuit whenever the lid is removed.
Product Codes
EN3-JB10
Elmdene 10 way Grade 3 White JB with
Tamper - 8 way plus 2 terminals for
Tamper
EN3-JB10-BN
Elmdene 10 way Grade 3 brown JB with
tamper - 8 way plus 2 terminals for
Tamper
EN3-JB9-HD
Elmdene 9 way HD Grade 3 white JB with
Tamper and Sealing Gasket - 7 way plus 2
terminals for tamper with environmental
class 3 sealing gasket
EN3-JB9-HD-BN Elmdene 9 way grade 3 brown JB with
tamper with sealing gasket. 7way plus 2
terminals for tamper with environment
class 3 sealing gasket
EN3-JB26
Elmdene 24 way Grade 3 white JB with
Tamper - 24 way plus 2 terminals for
Tamper
Chapter 1 Page 4
Intruder Catalogue
03/12
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 5
Chapter 1 - Accessories
Accessories
Mains Filtering
ACT1313 12Vd.c. Spike Supressor
Induced AC (Electromagnetic
Interference) is caused when Intruder
cables come near mains or telephone
wires. High induced AC voltage
causes random and intermittent false
alarms as well as system
malfunctions.
Very often, mains and other high
voltage cables are run next to alarm
circuits after the system has been
installed. Eliminating induced AC is
simple by fitting a ‘Spike Suppressor’
as standard in every control panel or
PSU.
The suppressor connects directly
across the DC supply and to mains
earth, dumping induced AC noise
and clamping the DC voltage against
‘spikes’.
Focus Mains Filter
This unit combines both transient
protection and filter protection. The
unit is designed to be hard-wired into
the mains terminal block across
neutral and earth. To obtain the best
performance from the device, the
leads should be kept as short as
possible. Note the device requires
external fusing which should be no
more than 13 Amps maximum, so it
must be connected downline of the
units fusing the system. The power
must be switched off during
connection.
Product Code
F-2323MSF
Focus Mains Filter
ACT 2468 Radio frequency filter.
The ACT 2468 is a powerful 1 Amp
rated RFI filter specifically designed
for use on any DC troublesome alarm
circuit cable. They are particularly
beneficial where data corruption
occurs to keypads and LIM’s
(especially on take-overs). They can
be used to attenuate RFI interference
to alarm detectors and sounders. The
ACT 2468 will work on 12V and
24Vd.c., normally closed, end of line,
ID and Fire Alarm circuits. They can
also be used to attenuate RFI on DC
Access Control circuits. The filter
offers virtually no resistance to DC
circuits, but will substantially
attenuate RFI signals between
2.5MHz -800MHz making them
quicker and more cost effective than
rewiring in screened cable.
Technical Specification
Dimensions:
41.5H x 11W x 4D
mm
Product Code
3127
ACT1313 12Vdc
Spike Supressor
Product Code
3141
ACT 2468 Radio
Frequency Filter
Relays
Product Code
609.001.015
24V Slave Relay double pole
changeover relay.
03/12
Hoyles S312N double pole interface
relay. This device accepts a variety of
input conditions (Voltage, Logic,
Closed Circuit and Open Circuit) for
interfacing various signals via voltage
free DPCO contacts.
With a self adhesive backing for easy
mounting. Four mounting holes are
also provided for more permanent
fixing.
Product Code
6504
Hoyles S312T double pole interface
relay. This device accepts a variety of
input conditions (Voltage, Logic,
Closed Circuit and Open Circuit) for
interfacing various signals via voltage
DPCO contacts.
The S312T is similar to the S312N but
its action can be delayed by up to
about 30 seconds. This can be
adjusted with the on board
potentiometer. This can be a useful
feature where it is necessary to delay
one action slightly to allow another.
It is supplied with a self adhesive
backing for easy mounting. Four
mounting holes are also provided for
more permanent fixing.
Hoyles S320 interface relay . This
device accepts a variety of input
conditions for interfacing various
signals (Voltage, Logic, Closed Circuit
and Open Circuit). Output via voltage
free SPCO contacts.
With a self adhesive back for easy
mounting.
Product Code
6698
Intruder Catalogue
Product Code
609.001.214
Chapter 1 Page 5
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 6
Chapter 1 - Accessories
Relays
12V Slave Relay double pole
changeover relay.
Elmdene Multipurpose Relay.
MPR001 MULTI-PURPOSE RELAY
Supply 12-13.8Vdc
Current 20mA
Trigger Input 1.5mA
Switch Load Maximum [email protected] 24V dc
or 0.5A @ 125V ac
Product Code
609.001.014
Dimensions 72Lx26Wx20D
Product Code
609.001.215
Contacted Locks
Chubb 3G11O D/C. Is a BS3621 5
Detainer Mortice lock complete with
73mm backset, SPDS single pole
changeover switch, DPDS Double
pole changeover switch.
Product Codes
4001-ICS
Chubb 3G110
D/C lock
4049-ICS
Chubb 3G114
D/C lock
A diecast metal box measuring
90H x 38W x 30D mm containing a
keyswitch and anti-tamper switch.
Brown. Boxed Outside Shunt D.C.
Product Code
4015
Lock
Document Box
Product Codes
9313
Document Box
(Keyed Alike)
9314
Key For Document
Box
Plastic folder for the inside of control
panel lids. For fitting adjacent to
control panels to keep system
information secure.
Window Stickers
Product Codes
604.002.183
Window Sticker
604.002.186
Surface Sticker
Window Sticker Reads "Secured by
ADT Fire and Security 24 Hour Alarm
Monitoring" (174mm x 60mm)
Surface Sticker Reads "Secured by
ADT Fire and Security 24 Hour Alarm
Monitoring" (174mm x 60mm)
Strobes
These high quality range of Xenon
Beacons are tested to IP65 making
them ideal for most stringent
applications.
Each beacon incorporates a low
profile Frestral lens designed to give
maximum light output.
Chapter 1 Page 6
Features
. Protected to IP65
. Attractive Low Profile
Technical Specification
Design
75 Dia x 51Hmm
Dimensions:
Intruder Catalogue
Product Codes
7174
Clear strobe 12V
1W
7464
Blue strobe 12V
1W
7609
Amber strobe 12V
1W
03/12
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 7
Chapter 1 - Accessories
Service Tools
Service & installations engineer products, each designed to enable engineers to provide a trouble free alarm installation
service.*
Minitran 452 Test Telephone Handset
The Minitran 452 is a new low cost
Telephone Test Set designed to
enable alarm technicians to test lines
and verify signals sent to the Alarm
Receiving Centre during
commissioning and maintenance
inspections. The tester has Talk and
Monitor modes to enable lines to be
tested without disrupting signals. The
tester also incudes DSP (Digital
Service Protection) which enables
safe operation where telephone wiring
may carry digital signals, hazardous
voltages or fault conditions. A “POL”
test button with Green/Red LED’s
indicates correct or reverse “A/B”
polarity connection.
The tester comes complete with easy
to use operating instructions and line
cable with Red/Black Crock-Clip
connectors.
Product Code
M0452-00
Minitran 452 test
Telephone
Handset
Features
• DSP – Digital Services Protection
• Safe with Data Lines
• Rugged Drop Proof Design
• Protected against 230 VAC
• Flat Battery - always ready feature
• Over Current Protection
• Battery Saving Auto Power-off
• Lightning Surge Protection
• Three Position Volume Boost
• Finger Tip Microphone Mute
• Headset Socket for Hands Free
• 32 Digit Last Number Redial
• Acoustic Shock Protection
GOLDPLUS Battery SLA Tester
GOLD-PLUS is an Intelligent Battery
Capacity Tester designed to test
6/12V lead acid batteries from 1.2Ah
to 100Ah. Its pulse load technology
simulates a 20 hour battery discharge
test in just 20 seconds, displaying the
Ampere-hour (Ah) capacity available
in the battery.
• Displays the Ah capacity available
in 6/12Volt lead acid batteries in
seconds
• Tests 6Volt SLA batteries from
1.2Ah to 12Ah and 12Volt from
1.2Ah to 100Ah
• Tests SLA batteries straight from
the box, partially or fully charged
• Can be calibrated to test Standby
SLA and Cyclic GEL batteries.
• Table indicates when batteries
should be recharged or replaced
• Quick, accurate and easy to use
instrument body and breaking/
invalidating the calibration seal
Product Code
ACT-AVO300
Product Code
GOLD-PLUS
ACT Gold-plus
Battery SLA
Tester
ACT-AVO300 ACT Autoranging Digital Meter
The NEW AVO300 from ACT Meters
provides a high resolution 4000 count
digital display and offers a range of
measurement modes for AC and DC
applications, resistance and current
measurement. The AVO300 also has
the added benefit of a separate
battery and fuse compartment,
meaning both battery and fuses can
be replaced without opening the main
03/12
ACT Autoranging
Digital Meter
• Fully auto-ranging 4000 count
digital display
• Separate fuse and battery
compartment, allows both to be
replaced without breaking the
calibration seals
• Tough rubber-armoured case
Intruder Catalogue
Chapter 1 Page 7
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 8
Chapter 1 - Accessories
This page is left intentionally blank.
Chapter 1 Page 8
Intruder Catalogue
03/12
Intruder_Ch2_AudioVerif:Layout 1 20/03/2012 09:36 Page 1
Chapter 2 - Audio Verification
Audio Verification
The basis of Audio Confirmation is to enable an Alarm Receiving Centre operator to listen in to a premises that has
signalled an alarm activation and allow the ARC operator to confirm if the alarm activation is genuine.
Confirmation of intruder alarm activations is now a requirement under the ACPO 2000 Security Systems Policy. This can be
done through sequential, audio or visual confirmation.
Features
• The audio verification unit is small enough to be fitted
inside most panel housings
• Up to 512 microphones can be fitted using full allowance
of expansion boards and hubs
• Each microphone has an automatic gain compensation to
counter noise swamping offering High intelligibility audio
• Microphone modules will operate on 1Km loop lengths of
ordinary alarm cable
• Microphone tamper contacts for anti tamper monitoring
• Individual microphone module audio level and recording
indicators
• Four 10 second pre-recorded messages can be played
back for user prompting (with expander)
• Relay output for controlling internal sirens and
programmable outputs
CSL Audio Verification Unit
The CS5000 Is a compact AVU designed to provide
confirmation of an unauthorised intruder presence. The
system comprises a small, low current control unit housed in
the same enclosure as the alarm panel. It has two
independent microphone inputs with an auto-learn feature
that enables it to be easily connected to the majority of
control panels.
The unit also has clean changeover relay contacts to silence
the internal alarm siren whether recording or transmitting
unauthorised sounds. Microphones are housed in a small
plastic case that can be surface or corner mounted and
each has a two-wire connection designed to operate over
long lengths of standard alarm cable without suffering from
interference.
Audio Verification
CSL Audio Verification Interface
Product Code
608.009.192
CSL CS5000-00 Audio Verification
Interface (PCB Only)
CSL Audio Verification Microphone
Product Code
608.009.193
CSL CS5010-00 Audio Verification
Microphone (up to 8 per standard
system)
CSL Expansion Board
CSL CS5020-00 Expansion Board for
CSL Audio Interface (608.009.192) to
allow connection of further 24
Microphones over 6 additional
busses-32 total.
Also includes Voice annunciation
features for the reduction of User
False Alarms
Product Code
608.009.194
LIM/Hub Expansion Board
Product Code
608.009.195
CS5030 AVU LIM/Hub Expansion
Board
03/12
Intruder Catalogue
Chapter 2 Page 1
Intruder_Ch2_AudioVerif:Layout 1 20/03/2012 09:36 Page 2
Chapter 2 - Audio Verification
This page is left intentionally blank.
Chapter 2 Page 2
Intruder Catalogue
03/12
Intruder_Ch3_Batteries:Layout 1 20/03/2012 09:43 Page 1
Chapter 3 - Batteries
Batteries
We supply a wide range of rechargable lead acid batteries to meet the needs of giving extra autonomy to your security
system.
Product Codes
Product Code
CS0388
PS-1212
PS-1221
PS-1230
PS-1242
PS-1270
PS-12120
PS-12170
PS-12260
PS-122380
PS-12650
PS-6100
Voltage
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
12V
6V
Product Code
660.002.028
TY-4103-F2
TY-4106-F2
TY-4122-F1
TY-6205-BL1
TY-GP910A-BL2
TY-CR2025-BL5
TY-CR2032-BL5
AP-1
AP6MTHS
B-02-8001
L91
CS0388
DOM-BAT-CRI
LED-BATTERY-PACK
Q3-BATT-SET
Q3MAINTKIT
7K67J
CR2450
LSH20
03/12
Autonomy
0.6Ah
1.2Ah
2.1Ah
3.0Ah
4.2Ah
7.2Ah
12.0Ah
17.0Ah
26.0Ah
38.0Ah
65.0Ah
10.0Ah
Dimensions
110 x 90 x 28mm
97 x 42 x 54mm
178 x 34 x 66mm
134 x 67 x 66mm
90 x 70 x 101mm
151 x 65 x 98mm
151 x 98 x 100mm
181 x 76 x 167mm
167 x 175 x 125mm
197 x 165 x 170mm
348 x 167 x 178mm
151 x 51 x 98mm
Weight (kg)
0.18
0.55
1.0
1.2
1.7
2.6
4.1
6.1
9.4
13.8
24.0
2.1
Battery
Alkaline 6V Battery (GP1412AP)
Varta Alkaline (1.5V/1350mAh) Battery: Size AAA
Varta Alkaline (1.5V/3200mAh) Battery: Size AA
Varta Alkaline (9V/600mAh) Battery: Size E
Flint CR123A lithium battery 2/3 A,
Gold Peak Alkaline (1.5V/0mAh) Battery; Size N
Gold Peak LI-MNO2 CR2025 3V
Gold Peak LI-MNO2 CR2032 3V
IBP Battery bundle for smoke
IPB old dye pack batteries
ETS replacement battery
L91 Lithium AA 1.5v Battery
CSL Dualcom replacement batt
HON DOM ADT 4VOLT 3.5AHR batt
ELM battery for LED module
IBP Q3 Battery
IBP Q3 Battery Set
Duracell 7K67J for EMS PA
3v Coin Cell Battery
3.6v 13Ah Saft Battery (for Optex RF Beams)
Intruder Catalogue
Chapter 3 Page 1
Intruder_Ch3_Batteries:Layout 1 20/03/2012 09:43 Page 2
Chapter 3 - Batteries
This page is left intentionally blank.
Chapter 3 Page 2
Intruder Catalogue
03/12
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 1
Chapter 4 - Contacts
Contacts (Magnetic)
Contacts offer a simple means of protecting doors, windows and roller shutters. The principle of operation is that one
element, (usually fixed to the non-moving section), contains a small switch encapsulated in a glass bottle, (called a
magnetic reed), and the other elements contain a magnet.
When the magnet is held within the operating gap of the magnetic reed, the switch is held closed and the circuit made. If the
magnet is moved outside the operating gap parameters, the circuit opens and an alarm is generated. Tyco Safety Products
stock a wide variety of contact to suit most applications.
EN50131 -2-6 Opening Contacts (Magnetic)
Changes are necessary due to the new EN standards
implementation of, Draft prEN 50131-2-6 Alarm systems Intrusion and hold-up systems Part 2-6: Opening contacts
(magnetic) that came into force back in April 2007, but this
was not adhered too due to their being a lack of different
types available and their reliability.
A) Be immune to any influence by the interference of the
magnet and continue to operate normally.
B) Generate an intrusion, and/or tamper, and/or fault, and/or
other independent signal or message in accordance with
the standard when the make or break distances exceed
twice those specified.
Major Change to grade 3
4.5.4 Magnetic field interference
When the detector is mounted in accordance with the
manufacturer's instructions and is subject to the presence of
an external magnetic field generated by the interference of
an external magnet and applied to the faces of the detector,
the detector shall either:
Flush Contacts - Grade 3
EN3-QFC-GN
Product Code
EN3-QFC-GN
White 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium.
White 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
EN3-QFC-BN-GN
Product Code
EN3-QFC-BN-GN
Brown 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium.
Brown 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
Surface Contacts - Grade 3
EN3-QSC-GN
Product Code
EN3-QSC-GN
Small white Surface Plastic, Contact
for use on Wood or Aluminium.
Small white Surface Plastic, Contact
for use on Wood or Aluminium.
Integral Resistors, for use in FSL or
DP systems, single or multiple doors.
Incorporating magnetic
detection/immunity.
EN3-QSC-BN-GN
Product Code
EN3-QSC-BN-GN
Small Brown Surface Plastic, Contact
for use on Wood or Aluminium
Small Brown Surface Plastic, Contact
for use on Wood or Aluminium.
Integral Resistors, for use in FSL or
DP systems, single or multiple doors.
Incorporating magnetic
detection/immunity.
03/12
Intruder Catalogue
Chapter 4 Page 1
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 2
Chapter 4 - Contacts
Surface Contacts - Grade 3 cont’d
EN3-LSC-GN
Product Code
EN3-LSC-GN
Large white Surface Plastic, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
Large white Surface Plastic,
Cabled Contact for use on
Wood or Aluminium.
EN3-LSC-BN-GN
Large brown Surface Plastic, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
Product Code
EN3-LSC-BN-GN
Roller Shutter Contact, Integral
Resistors, for use in FSL or DP
systems, single or multiple doors.
Incorporating magnetic
detection/immunity.
Product Code
EN3-RSA-GN
Roller Shutter Contact
Heavy Duty service Aliminium
Contact with 8 Terminals and 1K
Resistor.
Product Code
YM101KR
Large brown Surface Plastic,
Cabled Contact for use on
Wood or Aluminium.
EN3-RSA-GN
YM101KR
SC570-WH-MD-MULTI-G3
Product Code
SC570-WH-MD-MULTI-G3
Large white surface contact with 6
Term and selectable EOL
resistor values and tampers
Chapter 4 Page 2
Intruder Catalogue
03/12
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 3
Chapter 4 - Contacts
Spacers
These spacers will help in aligning up the magnet to reed
contact on doors that are off set or need a small amount of
levelling up. The spacers can be used on both the magnet
and or the door contact.
Features
• White, brown and Aluminium versions
• 3mm and 2.5mm sizes
• Can be used on contact or magnet
There are 5 different types to suit most of the surface range
and in Aluminium, brown and white versions.
LSC-SPC-BN
QSC-SPC-BN
QSC-SPC
LSC-SPC
S-SPC
4HD-SPC
4SM-SPC
Product Codes
S-SPC
4HD-SPC
4SM-SPC
LSC-SPC
LSC-SPC-BN
QSC-SPC
QSC-SPC-BN
03/12
Intruder Catalogue
3.0MM Spacer for use with S type
Contacts, 6S-GN
3.0MM Spacer for use with HD type
Contacts, 6HDSO-GN
3.0MM Spacer for use with SM type
Contacts, 6SM-GN
Pack of 5, 2.5MM Spacers for LST-GN
& EN3-LSC-GN Contacts
Pack of 5, 2.5MM Brown Spacers for
EN3-LSC-BN-GN Contact
Pack of 5, 2.5MM Spacers for QSC-GN
& EN3-QSC-GN Contacts
Pack of 5, 2.5MM Brown Spacers for
EN3-QSC-BN-GN Contact
Chapter 4 Page 3
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 4
Chapter 4 - Contacts
Grade 3 Specifications
Grade
Model
Application
Cabled/Terminals
Suitable for Wood or Metal
Fixing
Operation Mode
Single/Multiple Doors
Special Features
Material
Colour
Contact Details
Magnetic Detection/Immunity
Operating GapMinimum Close (mm)
Resistors Fitted
Number of Wires or Terminals
S/Steel Cable protection
Encapsulation
Contact Dimensions
& Fixings
Length (mm)
Width (mm)
Depth (mm)
Flange (mm)
Body Diameter (mm)
Cable Length (mm)
Fixings
Magnetic Details
Length (mm)
Width (mm)
Depth (mm)
Flange (mm)
Body Diameter (mm)
Fixings
Classification
TS50131-2-6 Grade
Environmental Class
Protection
Chapter 4 Page 4
Flush
3
EN3-QFC-GN
EN3-QFC-BN-GN
Surface
3
EN3-QSC-GN
EN3-QSC-BN-GN
3
EN3-LSC-GN
EN3-LSC-BN-GN
3
EN3-RSA-GN
Cabled
Cabled
Wood or Metal
Wood or Metal
Screws
Screws
FSL of DP
FSL of DP
Single or Multiple Single or Multiple
Magnetic
Magnetic
Immunity
Immunity
ABS
ABS
White or
White or
Brown
Brown
Cabled
Wood or Metal
Screws
FSL of DP
Single or Multiple
Magnetic
Immunity
ABS
White or
Brown
Cabled
Wood or Metal
Screws
FSL of DP
Single or Multiple
Magnetic
Immunity & Detection
Aluminium
Silver
Immunity
Immunity
Immunity
Detection
13
Yes
6W
No
Potted
9
Yes
6W
No
Potted
7
Yes
6W
50cm
Potted
22
Yes
6W
N/A
N/A
15
36 x 22.5
20
100
Screws
70
17
15
N/A
N/A
100
Screws
93
25
25
N/A
N/A
100
Screws
150
40
14
N/A
N/A
100
Screws
N/A
N/A
25
36 x 22.5
20
Screws
70
17
15
N/A
N/A
Screws
93
25
25
N/A
N/A
Screws
73
60
40
N/A
N/A
Screws
3
III
IP67
3
III
IP67
3
III
IP67
3
III
IP67
Intruder Catalogue
Potted
03/12
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 5
Chapter 4 - Contacts
Surface Contacts - Grade 2
6S-GN
Small surface fitting unit designed to
work on wooden or metal doors.
Product Code
6S-GN
Small metal surface fitting unit
designed to work on wooden or metal
doors.
Product Code
6SM-GN
Large size surface fitting unit with
terminals, designed to work on
wooden or metal doors.
Product Code
LST-GN
Medium surface contact designed to
work on large wooden or metal
doors, 2 m of cable provided.
Product Code
6SL-200-GN
Medium surface contact designed to
work on large wooden or metal
doors. Available in brown only.
Product Code
6SL-200-BN-GN
Medium surface contact designed to
work on large wooden or metal
doors.
Product Code
6SL-GN
Medium surface contact designed to
work on large wooden or metal
doors. Available in brown only.
Product Code
6SL-BN-GN
6SM-GN
LST-GN
6SL-200-GN
6SL-200-BN-GN
6SL-GN
6SL-BN-GN
03/12
Intruder Catalogue
Chapter 4 Page 5
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 6
Chapter 4 - Contacts
6PHD-GN
Large surface contact designed to
work on large or metal doors.
Product Code
6PHD-GN
Medium surface contact designed to
work on large wooden or metal
doors.
Product Code
QST-GN
Medium surface contact designed to
work on large wooden or metal
doors. Available in brown only.
Product Code
QST-BN-GN
Large surface contact designed to
work on large or metal doors, has
built in standoff.
Product Code
6HDSO-GN
QST-GN
QST-BN-GN
6HDSO-GN
VHDA-GN
Heavy duty unit aluminium with 8
terminals.
Product Code
VHDA-GN
6HD-GN-SS
Product Code
6HD-GN-SS
Large surface contact designed to
work on large wooden or metal
doors.
6RSL-100-GN
Small roller shutter contact designed
to work on large wooden or metal
doors.
Note: Non-handed
Product Code
6RSL-100-GN
Large Roller shutter contact designed
to work on large wooden or metal
roller shutter doors.
Note: Non-handed.
Direct replacement for old part number 1019.
Product Code
6RSA-100-GN
6RSA-100-GN
Chapter 4 Page 6
Intruder Catalogue
03/12
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 7
Chapter 4 - Contacts
Flush Contacts - Grade 2
6F-GN
A Pencil type flush fitting unit
designed to work on wooden doors.
Product Code
6F-GN
A small flush fitting unit designed to
work on wooden doors.
Product Code
6QFC-GN
A small flush fitting unit designed to
work on wooden doors. Available in
brown only.
Product Code
6QFC-BN-GN
A small white flush fitting unit
designed to work on wooden doors,
6 terminals with tamper cover.
Product Code
QFT-GN
A small brown flush fitting unit
designed to work on wooden doors,
6 terminals with tamper cover.
Product Code
QFT-BN-GN
Large flush fitting unit designed to
work on wooden or metal doors.
Product Code
6MDP-GN
6QFC-GN
6QFC-BN-GN
QFT-GN
QFT-BN-GN
6MDP-GN
03/12
Intruder Catalogue
Chapter 4 Page 7
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 8
Chapter 4 - Contacts
High Security - Grade 2
6FMBR-GN
High Security flush fitting contact with
cable, designed to work on wooden
or metal doors.
Product Code
6FMBR-GN
High Security flush fitting contact with
cable, designed to work on wooden
or metal doors.
Product Code
6VS105-GN
Large surface contact designed to
work on large wooden or metal
doors, has built in standoff.
Product Code
6HDBR-SO-GN
Large Roller shutter contact designed
to work on large wooden or metal
roller shutter doors.
Product Code
6VS222-GN
6VS105-GN
6HDBR-SO-GN
6VS222-GN
Note: This is a handed model and must not be
confused with the basic model 6RSA-100-GN.
The contact would be fitted to the LEFT side of
a roller shutter door when stood inside the
building looking towards the outside.
For the version to fit to the RIGHT side of a
roller shutter door when stood inside the
building looking towards the outside, part code
would be 6VS222-GN-REV available as an NSL
from Elmdene.
6VS302-GN
Product Code
6VS302-GN
Large surface contact designed to
work on large wooden or metal
doors.
* NOTE: Please see the following pages of charts for more detailed information regarding the above contacts.
Chapter 4 Page 8
Intruder Catalogue
03/12
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 9
Chapter 4 - Contacts
Grade
Model
2
6S-GN
2
6SM-GN
2
LST-GN
2
6SL -GN
6SL-BN-GN
Medium surface
contact designed
to work on large
wooden or
metal doors
ABS
White or Brown
65mm
12mm
12mm
65mm
12mm
12mm
Standard
1
2
QST-GN
QST-BN-GN
Medium surface contact
designed to work
on large wooden
or metal doors
Anodised
Silver
38mm
16mm
9.5mm
38mm
16mm
9.5mm
Standard
1
Medium size fitting
unit with terminals
designed to work
on wooden or
metal doors
ABS
White
86mm
25mm
20mm
86mm
25mm
20mm
Standard
1
2
6SL-200-GN
6SL-200-BN-GN
Medium surface
contact designed
to work on large
wooden or
metal doors
ABS
White or Brown
65mm
12mm
12mm
65mm
12mm
12mm
Standard
1
Application
Small surface fitting
unit designed to
work on wooden
or metal doors
Small metal surface
fitting unit designed
to work on wooden
or metal doors
Material
Colours
Contact Length
Width
Depth
Magnet Length
Width
Depth
Reed Type
No. of Reeds
Operating Gapmax
Encapsulation
Protection
Amount of
Cable wires
Cable Length
Cable Protection
S/Steel
2 x 1K/1K for EOL
EN50131/
PD6662 grade
ABS
White
38mm
14mm
8.5mm
38mm
14mm
8.5mm
Standard
1
25mm
Potted
IP67
15mm
Potted
IP67
40mm
6 Terminals
N/A
15mm
Potted
IP67
15mm
Potted
IP67
20mm
Terminals
IP43
6
1m
6
1m
0
6 Terminals
6
2m
6
1m
Terminals
N/A
No
No
N/A
No
No
No
EOL
2
EOL
2
EOL
2
EOL
2
EOL
2
EOL
2
Grade
Model
Application
2
6PHD-GN
Large surface contact to
to work on large wooden
or metal doors
Material
Colours
Contact Length
Width
Depth
Magnet Length
Width
Depth
Reed Type
No. of Reeds
Operating Gap-max
Encapsulation
Protection
Amount of
Cable wires
Cable Length
Cable Protection
S/Steel
2 x 1K/1K for EOL
EN50131/
PD6662 grade
03/12
ABS
White or Brown
67mm
14mm
13mm
67mm
14mm
13mm
Standard
1
2
VHDA-GN
Heavy duty Ali
with 8 Terminal
2
6RSL-100-GN
Small Roller Shutter
contact designed to
work on large
wooden or metal doors
2
6RSA-GN
Large Roller Shutter
contact designed
to work on large
wooden or metal doors
ABS
White
80mm
20mm
12mm
80mm
20mm
12mm
Standard
1
15mm
Potted
IP67
2
6HDSO-GN
Small metal surface
fitting unit designed
to work on wooden
or metal doors, has
built in standoff
Anodised
Silver
80mm
32mm
45mm
80mm
32mm
45mm
Standard
1
25mm
Potted
IP67
ABS
Silver
170mm
25mm
25mm
170mm
25mm
25mm
Standard
1
50mm
terminals
N/A
ABS
Silver
94mm
40mm
15mm
50mm
55mm
35mm
Standard
1
70mm
Potted
IP67
ABS
Silver
175mm
52mm
15mm
85mm
70mm
35mm
Standard
1
70mm
Potted
IP67
6
1m
6
1m
0
8 Terminals
6
1m
6
1m
No
Option
Yes
50cm
50cm
EOL
2
EOL
2
EOL
2
EOL
2
EOL
2
Intruder Catalogue
Chapter 4 Page 9
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 10
Chapter 4 - Contacts
Grade
Model
2
6F-GN
2
QFT-GN
QFT-BN-GN
A small flush fitting unit
designed to work on
wooden doors 6 terminals
with tamper cover
2
6MDP-GN
A Pencil type flush
fitting unit designed
to work on wooden
or metal doors
2
6QFC--GN
6QFC-BN-GN
A small flush fitting
unit designed to
work on wooden or
metal doors
Application
Material
ABS
ABS
ABS
ABS
Colours
Contact Length
White
34mm
White or Brown
15mm
White or Brown
15mm
White
34mm
Diameter Flange
Diameter standoff
Flange
8mm
36mm x 22.5mm
36mm x 22.5mm
38mm (Oval)
N/A
0mm
0mm
24mm
Diameter Body
8mm
20mm
20mm
12mm
Fixings
Magnet Length
Push In
34mm
2 Screws
15mm
2 Screws
15mm
2 Screws
34mm
Diameter Flange
Diameter standoff
Flange
Diameter Body
8mm
36mm x 22.5mm
36mm x 22.5mm
38mm (Oval)
N/A
8mm
0mm
20mm
0mm
20mm
24mm
12mm
Fixings
Reed Type
No. of Reeds
Push In
Standard
1
2 Screws
Standard
1
2 Screws
Standard
1
2 Screws
Standard
1
Operating Gap
max
Encapsulation
Protection
Amount of cable
wires
Cable Length
Cable Protection
2 x 1K/1K for EOL
EN50131/
PD6662 grade
10mm
18mm
18mm
7mm
Potted
No
Potted
No
Terminals
No
Potted
No
6
1m
No
EOL
6
1m
No
EOL
2
Terminals
No
EOL
6
1m
No
EOL
2
2
2
2
Chapter 4 Page 10
Large flush fitting unit
designed to work on
wooden or metal doors
Intruder Catalogue
03/12
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 11
Chapter 4 - Contacts
FLush Contacts - Grade 1(Service Use Only)
QF-5
A small white flush fitting contact
designed to fit on wooden doors
5 x terminals.
Product Code
QF-5
A small brown flush fitting contact
designed to fit on wooden doors
5 x terminals.
Product Code
QF-5-BN
QF-5-BN
Grade
Model
Application
Material
Colours
Contact Length
Diameter Flange
Diameter standoff
Flange
Diameter Body
Fixings
Magnet Length
Diameter Flange
Diameter standoff
Flange
Diameter Body
Fixings
Reed Type
No. of Reeds
Operating Gap
max
Encapsulation
Protection
Amount of cable
wires
Cable Length
Cable Protection
2 x 1K/1K for EOL
EN50131/
PD6662 grade
03/12
1
QF-5
QF-5-BN
A Small flush fitting
contact with 5
terminals and no
resistors to work on
wooden doors
ABS
White or Brow
15mm
36mm x 22.5mm
0mm
20mm
2 Screws
15mm
36mm x 22.5mm
0mm
20mm
2 Screws
Standard
1
18mm
N/A
No
0
0
No
No
1
Intruder Catalogue
Chapter 4 Page 11
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 12
Chapter 4 - Contacts
This page is left intentionally blank.
Chapter 4 Page 12
Intruder Catalogue
03/12
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 1
Chapter 5 - Day Alarms
Day Alarms
EXITGUARD is the ideal solution for security of fire exit doors in Supermarkets, Hotels, Restaurants, Warehouses, Leisure
Centres and all types of public buildings. It satisfies the requirements of both fire and security officers.
An integral high power sounder is activated when the door is opened to warn those in the vicinity that security has been
breached.
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Hoyles Exitguard
This new EXITGUARD uses a nine digit keypad for both
control and programming. The tone of the high power
integral alarm can be selected to distinguish it from other
alarms. The alarm can be silenced and reset using a four
digit code or the EXITGUARD can re-arm automatically after
a preset delay once the door has been closed. Separate
Door Open Too Long (DOTL) delays can be set for Code
Reset and Auto Reset modes. There is also a Bleep In Off
option and Chime facility. There are a number of different
models to suit various applications:
EX204 is battery powered for use where a separate supply
of power is not available and the protected door is opened
infrequently or there is no requirement to sound the integral
sounder for long periods. If necessary the integral battery
can be dispensed with and a separate 12vdc supply
provided. This version has a logic output signal for
connection to a MULTIGUARD indicator.
High Power Piezo Sounder
Keypad Control
Auto Reset / Re-arm Delays 0 - 88s
Separate Door Open Too Long Delays for
Keypad & Auto re-arm. 0s - 88s
Bleep In Off option
Front & Back Acting Tamper Switch
Battery, 12 Vdc & Mains Versions
Selectable Alarm Tones
Visual Alarm Indication
Chime Facility
Alarm Relay Output
On - Off Monitor Relay
Fire Door Checker
This version is also supplied with 6 x AA alkaline batteries for
standby - Note: the batteries will not power the alarm relay.
All are supplied with a surface mounting door contact, fixing
screws and a door warning label.
Fire Door Checker
This unique feature enables the EXITGUARD to be used
to verify that all emergency fire exit doors are available for
use when a building is occupied. Simply wire a switched
signal from the intruder alarm control of the building to each
EXITGUARD. As soon as the alarm is switched off when the
building is opened staff are forced to visit each fire door in
turn and release the door to ensure that it is ready for
emergency use. The normal EXITGUARD functions are then
automatically restored to give protection against
un-authorised exit.
EX205 is 12vdc powered for use where the protected door
may be opened frequently or the integral sounder may need
to sound for long periods. This version can also be used as
equipment.
There is a logic output signal for connection to a
MULTIGUARD and there are volt free relay contacts for
separately signalling ON/OFF status and alarm conditions at
remote points. This version cannot be powered from
batteries. EX206 is 230vac mains powered where the
protected door may be opened frequently or the sounder
may need to sound for long periods. There is a logic output
signal for connection to a MULTIGUARD and a volt free relay
contact for alarm condition.
03/12
Intruder Catalogue
Chapter 5 Page 1
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 2
Chapter 5 - Day Alarms
Technical Specification
Specification
EX204
EX205
Supply Voltage
9vdc -15Vdc
11 - 14vdc
220/240Vac
Supply Current
35μA quiescent
45mA quiescent
< 0.5A
80mA max
155max
Battery
6 x AA Alkaline
None
Fusing
None
None
Visual Indication
5 Status LEDs
5 x Status LEDs Red,
EX206
6 x AA Alkaline
1A BS1662 Mains fuse
1 x Power LED Green
Status LEDs strobe with sounder on alarm on all models
Integral Sounder Level
102 - 104 db at 1 metre dependant on input voltage
Four programmable tones, two loud, two quiet
Input
All models: Double pole four wire. Alarm loop and tamper loop.
Remote Input for FDC
Apply +ve signal when building is closed remove when occupied for fire
door verification
Bleep in Off
Programmable on all models. Disabled on factory default
MULTIGUARD O/P
All models normally Logic Hi, Logic Lo on alarm
Tamper
Normally closed back & front acting tamper switch all models
Alarm Relay Contacts
None
SPCO 1A 30Vdc for connection to remote devices
On / Off Monitoring Relay None
Auto Reset Timer
SPCO 1A 30Vdc None
Programmable 0 - 88secs all models
Door Open Too Long
Timer
Programmable 0 - 88secs all models
Enclosures
Custom designed ABS plastic back box with mark resistant decal
Door Contact
Surface mount magnetic reed contact with 1m 4 core cable.
Exitguard 24hr Door Alarm & Fire Door Checker
Fire Door Checking Facility This unique feature enables the
EXITGUARD to be used to verify that all emergency fire exit
doors are available for use when a building is occupied. This
can be achieved in one of two ways, either: A. Wire a
switched 12Vdc +ve signal from the intruder alarm control
of the building to each EXITGUARD. or B. Wire a switched
12vdc +ve signal from a time clock to each EXITGUARD.
Chapter 5 Page 2
Whenever the alarm is switched off or when the time clock
removes the signal, the EXITGUARD will emit a double bleep
every 90 seconds and the LEDs will strobe. Staff must visit
each fire door in turn and release the door to ensure that it is
ready for emergency use. The normal EXITGUARD functions
are then automatically restored to give protection against
un-authorised exit. To conserve battery life it is
recommended that the EXITGUARD is centrally powered as
shown below.
Intruder Catalogue
03/12
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 3
Chapter 5 - Day Alarms
Exitguard 24hr Door Alarm & Fire Door Checker
Fire Door Checking Facility
This unique feature enables the EXITGUARD to be used to
verify that all emergency fire exit doors are available for use
when a building is occupied. This can be achieved in one of
two ways, either:
A. Wire a switched 12vdc +ve signal from the intruder alarm
control of the building to each EXITGUARD. or B. Wire a
switched 12vdc +ve signal from a time clock to each
EXITGUARD.
Whenever the alarm is switched off or when the time clock
removes the signal, the EXITGUARD will emit a double
bleep every 90 seconds and the LEDs will strobe. Staff must
visit each fire door in turn and release the door to ensure
that it is ready for emergency use.
The normal EXITGUARD functions are then automatically
restored to give protection against un-authorised exit. To
conserve battery life it is recommended that the
EXITGUARD is centrally powered as shown below.
Product Codes
EX204
EX205
EX206
9vdc -15Vdc Hoyles Exit Guard
11 - 14Vdc Hoyles Exit Guard
220/240VacHoyles Exit Guard
System Diagram
Method A
Fire Door 2
Storeroom
Door
Method B
12vdc supply. This can be a separate supply
but the-ve should be common for both
Fire Door 2
Storeroom
Door
When the intruder control is armed a 12vdc+ve
is applied to the R terminal of each EXITGUARD.
Fire Door 1
Fire Door 3
Fire Door 4
-+s
Intruder
Control
Fire Door 1
A 12 vdc+ve signal of at least 1 second duration is applied to the R terminal of each EXITGUARD at suitable time intervals. This would
usually be at least daily, possibly twice daily.
Most time clocks with independent voltage free
clean contact would be suitable.
Fire Door 4
12 vdc
Power Supply +
240vac supply
240vac supply
03/12
Fire Door 3
Intruder Catalogue
Chapter 5 Page 3
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 4
Chapter 5 - Day Alarms
Aidalarm
Features
•
•
•
•
•
•
•
•
•
•
DDA Compliant
BS8300 Compliant
High Power Piezo Sounder
12 Vdc & Mains Versions
Audible & Visual Signalling
Range of Accessories
Selectable Alarm Tones
Remote Signalling Output
Choice of Four Warning Tones
No Part B Building Regulation Conflicts
AIDALARM A600M Mains/12vdc Powered
AIDALARM A600M Mains/12vdc Powered
This is similar to the A600B but can be used to create a
more comprehensive system with the addition of a remote
reset button, remote indicator/mute unit with separate LED
and sounder controls or overdoor light / sounder.
The A600M is fitted with a volt free output relay for
connection to a MULTIGUARD indicator or a building
management system. The A600M can be powered from
either 12 volts dc from an external power supply or from
230/240 vac mains power. There is also an option for a
rechargeable standby battery (not supplied) when powered
from the mains supply.
The integral 12 volt dc supply will provide power for external
items such as overdoor lights etc.
AIDALARM can also be used with REDIPRESS switch strip to enable an alarm
condition to be generated near ground level. Various other options are available
using remote indicators, overdoor lights and resets. Please contact us for more
details or visit www.hedsolutions.co.uk
Chapter 5 Page 4
Intruder Catalogue
03/12
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 5
Chapter 5 - Day Alarms
Multiguard Disabled Toilet Alarm System
The AA31110D MULTIGUARD is a six zone disabled
toilet alarm system for larger buildings that need central
indication of the origin of the call. It is designed to give dual
re-assurance indication at the point of operation.
Operation
When a pull cord (S1600) is operated its LED flashes and a
local buzzer (S/1678) sounds to inform the caller that the call
has been transmitted. When the call is silenced at the panel
the flashing LED becomes steady and the local buzzer
silences to inform the caller that the call has been received
and help is on the way.
If the caller pulls the cord again the LED on the pull cord will
flash and the local buzzer sounds again. When help does
arrive the call is reset using the local (S/1608) reset button.
All LEDs and buzzers, flashing or steady, are extinguished.
An integral PSU and battery are included in the AA31110D
Multiguard.
The above schematic shows only a three zone system for
clarity. The system requirements for a six zone system are
as follows:1 x AA31110D per six zone system
1 x S1600 or S/1605 per toilet
1 x S1678 per toilet
1 x S1608 reset button per toilet
Product Codes
Technical Specification
Dimensions:
Power:
Current:
HXWXD
90 x 156 x 57mm
12Vdc or 240Vac
Output 200mm
609.001.206
609.001.211
609.001.212
609.001.214
609.001.215
S1778SR
609.001.312
A600M
6504
6698
609.001.211
S1609S
S1613S
S1705S
S351
03/12
Intruder Catalogue
Hoyles Light/Sounder S1678
Hoyles Pullcord/LED S1600
Hoyles Reset Button S1608
Hoyles 30 SEC Timer RelayS312T
Multipurpose Relay
Over door A/V unit stainless steel
Hoyles S1608P Reset Button S/M
Hoyles mains/12VDC powered Aidalarm
Hoyles S312N DBL Pole Relay
Hoyles S320 SGL Pole Relay
Hoyles Replacement cord for S1600 pull
cord
Hoyles 2 position keyswitch on stainless
steel single gang plate
Hoyles Mushroom headed latching button
with key reset facility on stainless steel
single gang plate
Call button and LED on stainless plate
Hoyles Universal timer/relay module
Chapter 5 Page 5
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 6
Chapter 5 - Day Alarms
Hoyles Multiguards
The MULTIGUARD 2000-6 is a general purpose six zone annunciator. The enclosure design is such that virtually any
system size can be met by stacking units together.
To cater for the many different requirements of the emergency alarm market the Multiguard is supplied in a number of
different guises, each of which offers a remarkable degree of flexibility.
Features
•
•
•
•
•
•
•
•
•
•
Custom Design Case
Integral P.S.U. & Battery Option
Integral Piezo Sounder
Unique Labelling System
Open or Closed Circuit Inputs
D.P.C.O. Global Output Relay
Lamp Test Option
Nurse Call Version with late attendance
Emergency re-call Facility
Total Flexibility
Multiguard
Possible uses for the Multiguard are Perimeter Protection
Systems, Personal Attack Monitoring, Fire Exit Door
Monitoring (e.g. EXITGUARDs/AIDALARMs) and Nurse Call
Systems. There are also many other applications in the field
of process monitoring such as Deep Freeze Alarms.
Technical Specification
MG212000 & MG212100 General purpose annunciators.
These Multiguards are the basic versions used for general
purpose monitoring where zone isolation is not required.
The MG212100 is fitted with an integral 12v 250ma PSU and
standby rechargeable battery. In all other respects these two
versions are identical.
When the cause of the alarm condition has been
investigated and cleared F2 can be pressed to RESET the
visual indication. If a subsequent alarm condition occurs
before earlier ones are cleared then all prior indications are
temporarily suppressed in order to emphasise the latest
event.
MG216000, MG216010 & MG216110 Annunciators with
Zone Isolate facilities. These are specified where zone
isolation facilities are required.
The operation is similar to the basic units. However, they are
fitted with six zone buttons Z1 - Z6 and, in the case of the
MG216010 & MG216110, a keyswitch. An alarm condition is
given in the same way as outlined above. In order to
SILENCE the alarm condition the relevant zone button is
pressed. When the cause of the alarm condition has been
cleared the zone button is pressed again to RESET the
indication. The zone buttons also have two further facilities,
a. to act as ISOLATE switches and b. to facilitate LAMP
TEST. Turning the keyswitch enables zone isolate. Pressing
a zone button illuminates an LED to indicate that the zone is
ISOLATED. Pressing the button again reinstates the zone.
Pressing any two zone buttons simultaneously tests each of
the LEDs in turn. If more than six zones are needed then a
number of units would be stacked together. The primary unit
would probably be an MG216110 which would support up
to 3 secondary units to expand the system capacity to 24
zones. These secondary units could be MG216000 versions
which would use the keyswitch and power supply of the
primary unit.
When an alarm condition is detected an audible warning is
given by the integral piezo sounder, the relevant zone LED
flashes, and a global relay energises to provide volt free
DPCO contacts for signalling to other equipment.
By pressing F1 the sounder is SILENCED, the alarm
condition is accepted, the global relay restores to normal
and the LED flashes more slowly.
Chapter 5 Page 6
Intruder Catalogue
03/12
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 7
Chapter 5 - Day Alarms
MG222000, MG226000 Repeaters.
It is often necessary to repeat indications at remote
locations. Each Multiguard master is equipped with a serial
output to enable data to be sent to a number of repeaters
simultaneously. Each Multiguard master with an integral
power supply can support up to three repeaters. If more
than three repeat locations are needed then an external
power supply should be used at the master. Because data is
sent out serially to the repeaters a reduced number of cable
cores are needed. If indication only is required
with no control functions then a five core cable will suffice
(an extra 3 cores are needed for each block of six zones) If
control functions are used then extra cores will be required,
(consult our technical department for details).
Multiguard repeaters are identical in appearance and user
functions to master units. Repeaters can be fitted with
keyswitches in the same way as master units for isolation or
other purposes.
MULTIGUARD Options
A keyswitch MG000010 can be added to any Multiguard not
already fitted with one. The keyswitch is a two position with
double pole changeover contacts. If a keyswitch is used for
isolation purposes then only the second pole is available for
an alternative use. This is obviously restricted to functions
that are coincidental with isolation. Two interface cards are
available to enable Multiguard annunciators to drive external
equipment. The MG020000 uses serial data from a master
unit to provide up to 16 outputs capable of switching up to
500ma per zone (subject to psu limit). Six outputs follow the
annunciator LEDs. Six further outputs switch on alarm
condition and restore on reset. Two outputs follow the
integral sounder and global relay. Two outputs are not
nominated.
Nurse Call Items.
S1600P is a manual latching call point with jumbo
re-assurance LED. Pressing the button generates the call,
pressing again resets it. The latching button can also be
used to illuminate and overdoor indicator (see below).
It designed for either surface or flush mounting on a
standard single gang electrical box.
The S1663P is an advanced electronic call point capable of
standard and emergency re-call. It is also generates a late
attendance signal. Calls are also reset at these points.
Pillow
Pushes or Ceiling Pull-Cords may be connected to
Electronic Call Points. When a call is generated a late
attendance timer is activated. If the call is not attended to
and reset within a predetermined period (adjustable on
installation at each call point between 30 seconds and 2/
minutes) a late attendance alarm is generated at the panel.
An emergency re-call can be generated at any time by
pressing both the reassurance LED and the re-call
button simultaneously at the call point. An output is available
from the call point for overdoor or corridor indicators.
S1636RP is an overdoor or corridor indicator.
These cards will fit into the Multiguard back box as shown.
Dimensions 135 x 67 x 15 (mm).
The MG030000 takes the serial data from a master unit to
provide six relay outputs with voltage free DPCO contacts
(1A/30vdc resistive). The activation of these relay outputs is
dependant upon the software configuration of the master
unit. These cards are often used to interface with CCTV
multiplexers. The cards must be housed separately. Power
requirement 12vdc 70ma. Dimensions 142 x 110 x 15 (mm)
MG311000 Nurse Call annunciators.
The principle of operation is similar to the Multiguard
general purpose annunciators. There is a SILENCE button
F1 but no reset button or isolate facilities are fitted. Integral
power supplies are NOT usually fitted to these versions as
extra power is needed for call points and overdoor lights etc.
The control logic is non-latching. When a call is made an
audible warning is given by an integral piezo sounder and
the relevant zone LED flashes. The sounder can be silenced
at the panel but must be reset at the call point.
Nurse call annunciators have facilities for Late Attendance
indication. When a late attendance condition is generated
the Multiguard emits an interrupted pulsed tone
accompanied by an interrupted flashing LED for the relevant
zone. Similar but continuous pulsed signals are used for
Emergency Re-call. Signals are graded - late attendance
takes priority over standard calls and emergency re-call take
priority over late attendance.
Manual and Electronic Call Points can be used on the
same installation. However, late attendance and emergency
re-call are only possible with electronic call points.
When used in a Multiguard nurse call system it derives its
power from either a manual or electronic call point. It is
designed for either surface or flush mounting on a standard
single gang electrical box.
EXITGUARD Self contained door alarm The EXITGUARD is
the ideal solution for the security of fire exit doors. Not only
in nursing and residential homes but also in supermarkets,
hotels, restaurants, warehouses, leisure centres and other
public buildings. It satisfies the requirements of both fire and
security officers. A number of versions are available and
they can be linked back to Multiguard annunciators. (Only
the EX500 and EX600 are suitable for nurse call
annunciators. Separate information available).
Product Codes
609.001.202
609.001.203
609.001.204
609.001.205
S1778PR
609.001.211
S1708S
609.001.214
03/12
Intruder Catalogue
Hoyles Multiguard 6ZN MG212100
Hoyles Multiguard EXT MG212000
Hoyles Multiguard RPT MG222000
Hoyles Multiguard K/S
Overdoor light and buzzer with 8 red
LEDs white plastic plate
S1600
Reset button on stainless steel plate
Hoyles 30 Sec Timer Relay S312T
Chapter 5 Page 7
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 8
Chapter 5 - Day Alarms
Elmdene Battery Day Alarm
This unit is designed to be a completely self contained alarm unit, ideal for situations which need to be guarded when the
normal day alarm is disarmed.
Features
• On/Off keylock
• Battery test push Button and LED
• Easy to Install
Day Alarm
Complete with tamper switch, 2 or 4 wire detection circuits
the unit will operate in standby mode for 6 months and in
alarm mode for 3 hours from a fresh, dry battery.
The Day alarm is provided with a standard 2 screw
terminal magnetic contact and works on a closed loop
detection basis.
Technical Specification
Dimensions:
Battery:
Output:
Magnetic Contact:
Chapter 5 Page 8
190H x 155W x 55D mm
PP9 Dry Cell
[email protected]
Normally open
A battery test push button enables the battery to illuminate
an LED if there is still sufficient charge in the battery.
All necessary fixing screws and 8m of twin core bell flex are
provided with this unit.
Product Code
6356
Intruder Catalogue
Elmdene Battery Day Alarm
03/12
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 9
Chapter 5 - Day Alarms
Zone Omit Modules
ZONEGUARD ZG800 is a Grade 3 EN50131 zone omit unit that fits between intruder detection devices and a control panel
to allow the devices to be securely and safely omitted and reinstated without generating false alarms.
Features
• Complies with EN50131 Grade 3
• Designed for detectors with separate alarm,
anti-masking and tamper facilities
• Rear acting Tamper switch/Omits two detection zones
• Integral high security keyswitch 250,000+ differs
• Integral 9 digit keypad 500,000 differs
• Dual responsibility or combination mode gives over 300
million differs
• Zone status LEDs, Fault LED
• Integral piezzo sounder
• Output for remote sounder, Independent zone omitted relay
• Input for remote devices, keyswitches, shunt locks,
biometric readers etc..
• User programmable code change/Timed entry/exit modes
• Suitable for use with other detection devices e.g. door
contacts
Zone Omit Modules
Grade 3 passive infra red/DualTec detection devices must
be fitted with independent anti-masking and tamper
detection.
The unique design of the ZONEGUARD allows the various
'end of line' resistors for each conditions to be passed
through to the control panel unimpeded.
In this way the detectors resistors are monitored directly by
the panel. Any value of alarm resistor greater than 1k can be
used by ZONEGUARD.
Other modes are available using the integral keypad or
external devices such as biometric reader or a combination
of keyswitch and keypad, this is useful where dual
responsibility is essential. Two timed entry/exit modes are
also available.
General Rules
Zones will always omit using an omit function. If any zone
has a detection condition during reinstatement, then it must
be returned to omitted state and the detection condition
cleared and then reinstated.
In its simplest mode ZONEGUARD uses its integral
keyswitch to omit or reinstate up to two detection zones.
Wiring Diagram
03/12
Intruder Catalogue
Chapter 5 Page 9
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 10
Chapter 5 - Day Alarms
Operational modes
This mode is useful where dual responsibility is desirable.
• Integral keyswitch mode. (Factory default) The keyswitch
is a 7 pin tumbler with over 250,000 differs. Grade 3
requirement is for 30,000+ differs
• Timed entry/exit, integral keyswitch to execute.
• Integral keypad mode. The integral 9 digit keypad using a
6 digit code gives over 500,000 differs. Grade 3
requirement is for 100,000 differs.
These last two timed entry/exit modes offer a higher degree
of security because the procedure must be completed within
a time window and the ZONEGUARD can be sited within
one of the protected zones.
A 10 second keypad lockout is incorporated after 5
incorrect codes are entered. 'Start again' is also
incorporated if no digit is entered within 8 seconds.
• Remote latching input mode, e.g. keyswitch. This would
need to be at least 30,000 differs.
• Remote non-latching input mode, e.g. biometric, card
reader or similar. Modes 3 and 4 permit the ZONEGUARD
to be fitted within one of the protected zones.
• Timed entry/exit, integral keypad to execute.
Any device can be used to activate the time window, this
could be a door contact or detector. The activation device
should not be considered to be part of the intruder detection
system but simply a device to start a procedure.
The ZONEGUARD requires a supply of 12vdc. (Quiescent
120ma in omitted state 200ma peak during programming).
The non-volatile memory stores mode settings, time delays
and codes in case of power down.
• Combination of integral keypad & integral keyswitch. The
9 digit keypad used with a 4 digit code and the integral
keyswitch gives over 3000 million differs. Use of a 4 digit
code is only possible in this combination mode.
Product Code
ZG800
Chapter 5 Page 10
Intruder Catalogue
Zone Omit Module
03/12
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 1
Chapter 6 - Detectors Beam
Beam Detectors
While movement detectors detect the movement of the body in a room the following detector will monitor the entry
through a protected perimeter.
Photoelectric Beam Detectors
Features
• Twin Synchronised Pulsed Beams Designed
for Greater Stability
• Selectable 4-Channel Beam Frequencies
• Adjustable beam interruption time - long interruption time
catches an intruder but allows a small animal to pass
through
• Twin beams require simultaneous interruption to create
activation
• 99.5% beam blocking stability
• Easy installation and alignment using viewfinder for rough
alignment and voltage meter jacks for fine-tuning
• Sealed optics to prevent ingress of insects and dust
Optex AX-130T/200
The AX-70/130TN Twin beam photoelectric sensors,
designed for short-range outdoor or long-range indoor
applications. Using twin beams of pulsed infrared energy,
reliable operation is possible in the worst conditions - up to
99% of the emitted radiation can be blocked by rain, fog or
falling snow and the beams will still operate.
By utilising an automatic gain control circuit, gradual
changes in signal strength caused by weather conditions
are continually monitored and the trigger level adjusted
accordingly to compensate. In addition, the unique
anti-frost design allows for trouble-free operation when the
cover is completely frosted over. The Series achieves the
IP65 high durable structure by using the rubber packing for
all conceivable points and it prevents the rain, dust, and tiny
insect getting into the unit.
AX-100/200TF is a compact photoelectric detector with “the
IP65 high durability”, and “stable detection performance”.
These features reduce false alarms drastically - caused by
outdoor severe environmental changes and provide a wide
range of applications.
AX-350/650TF Series photobeams are dual beam longrange sensors with a host of sophisticated extra facilities.
They are ideal for larger installations where they are
capable of external ranges up to 200m. The beams offer
four site-selectable frequencies that allow them to be
stacked one above another to provide a wall of coverage.
To reduce setup and alignment time to a minimum,
AX-350/650TF units include a one-man alignment facility,
A third infrared beam sends alignment information from the
receiver to the transmitter and allows the installer to see the
status of the received signal at the transmitter.
Input voltage is between 10.5 and 30V DC giving flexibility
in system design, particularly where large sites have remote
power supplies. The AX-350/650MKII’s dual beams reduce
the potential for false activation from birds or blowing
debris.
The AX-350 & 650DHMKIII are the World’s First Next
Generation photoelectric sensors with full digital
communication.
03/12
This new AX series delivers excellent performance in
preventing missed and false alarms, while allowing for even
easier installation which makes the whole installation
process more cost effective.
By using full digital packet communication, the new AX
series is able to transmit the address setting, cover
open/close information and the arrival level of beam power
simultaneously. The new Time Division Multiplex System
prevents any crosstalk beams when multiple beams are
installed on site or when beams are stacked. This greatly
reduces the risk of false or missed alarms, as well as
removing the need to manually choose channel settings.
The new IP65 rated casing prevents problems caused by
water or dust, while the new Anti-Frost hood cover prevents
any build-up of frost over the upper and lower beams.
Input voltage is between 10.5 and 30V DC giving flexibility
in system design, particularly where large sites have remote
power supplies.
Note: These cannot be mixed with any other beams from
the range on the same site. For more information, please
contact Optex technical department.
AX-701/130T Infrared Photoelectric
BAX-701/130T Infrared Photoelectric
Beam
Twin beam photoelectric detectors, designed for short-range
outdoor or long-range indoor applications.
Using twin beams of pulsed infrared energy, reliable
operation is possible in the worst conditions - up to 99% of
the emitted radiation can be blocked by rain, fog or falling
snow and the beams will still operate.
By utilising an automatic gain control circuit, gradual
changes in signal strength caused by weather conditions
are continually monitored and the trigger level adjusted
accordingly to compensate. In addition, the unique antifrost design allows for trouble-free operation when the cover
is completely frosted over.
Intruder Catalogue
Chapter 6 Page 1
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 2
Chapter 6 - Detectors Beam
Technical Specification
Model
Detection Method
Maximum detection range
Maximum arrival range
Interruption period
Selectable beam frequency
Power supply
Current consumption
(transmitter + receiver)
Alarm period
Alarm output
D.Q. Output
Tamper switch
Operating Temperature
Operating Humidity
Alignment angle
Mounting
Weight (transmitter + receiver)
Housing protection (EN 00529)
Model
Detection method
Range Outdoor
Indoor
Maximum arrival distance
Beam characteristics
Selectable beam frequency
Interruption period
Power Supply
Current consumption
(transmitter + receiver)
Alarm period
Alarm output
Tamper Switch
Operating Temperature
Environment Humidity
Alignment Angle
Alarm memory
Environmental disqualification
Circuit
Mounting
Weatherproof
Weight
AX-130T
AX-100TF
AX-200TF
Infrared beam interrupted detection
30m
300m
60m
600m
Selectable between 50, 100, 250, and 500m sec.
4 channel
10.5 - 28V DC
44mA(max.)
48mA (max.)
2 sec. (±1) nominal
N.C./N.O. 28V DC, 0.2A (max.)
N.C. 28V DC, 0.2A (max.)
Opens when cover is removed at 28V DC, 0.2A max.
-35°C to +60°C Use the optional heating unit (HU-3) in conditions of -25° C or below.
95% max.
±90° Horizontal, ±5° Vertical
Wall and pole mounting
700g
IP65
AX-350TF
AX-650TF
Infrared Photoelectric
100m
200m
1000m
200m
400m
2000m
Pulsed Infrared
4 channel
50,100,250,500 msec (4 steps)
10.5-30VDC
Normal operation 60mA Max
Normal operation 82 mA max
T:11mA+R±49mA
T:13mA+R±49mA
During optical alignment 78mA max
During optical alignment 80mA max
T:11mA+R±67mA
T:13mA+R±67mA
2sec(±1) nominal
Form C Relay (28VDC 0.2A max)
N.C. opens when cover is removed
-35°C ~ +60°C
96% MAX
±10° VERTICAL, ±90° Horizontal
LED indicates memory status. Selectable Negative & Positive
Form C relay operates when beam energy has been gradually reduced to abnormal level
Gradually reduced to abnormal level
Wall or Pole
IP54
2750g Transmitter and Receiver
Indoors
100m
Outdoors
200m
Product Codes
AX-130T
Optex External/Internal Synchronised twin
beam, 40M outside range
AX-200TF
Optex External/Internal Synchronised twin
beam, 60M outside range
AX-350TF
Optex External/Internal Synchronised
Photoelectric twin beam, 100M outside
range. 4 Channel frequencies
AX-650TF
Optex External/Internal Synchronised
Photoelectric twin beam, 200M outside
range. 4 Channel frequencies
AX-350DHMK111 Optex External/Internal Digital
Synchronised twin beam, 100M outside
range.
AX-650DHMK111 Optex External/Internal Digital
Synchronised twin beam, 200M outside
range.
Chapter 6 Page 2
Intruder Catalogue
03/12
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 3
Chapter 6 - Detectors Beam
Features
• Long battery life AX-100TFR: approx. 5 years AX-200TFR:
approx. 3 years
• Easy battery replacement
• Triple tamper functions
• Low battery output and LED indication
• Intermittent output function
• Compatible with numerous wireless transmitters
• Battery saving timer function for wireless transmitters
• International protection IP55
• Easy angle adjustment function
• Beam interruption adjustment function
• 99% Beam blocking stability
• N.C./N.O. output selection switch
• 4 selectable beam frequencies
AX-100/200TFR
The new AX-100TFR and AX-200TFR from OPTEX is a
revolution in the perimeter security industry, offering a
significant cost saving alternative to traditional hardwired
system. No trenching is required, drastically reducing
installation costs. The unit comes wireless ready with a
multifunctional back box and is compatible with most
manufactures wireless systems.
The AX-TFR series uses four 3.6V batteries with an average
lifespan of 5 years on the 100ft model and 3 years on the
200ft model.
Note: Use 2 x Honeywell DODT8M Transmitters
Model
Range
Maximum arrival distance
Detection Method
Beam frequency selection
Interruption period
Power Source
AX-100TFR
AX-200TFR
30m
60m
265m
530m
Infrared beam interruption detection
4 channel
Variable between 50,100, 250, 500 msec (4steps)
3.6V 13.0 Ah: LSH20 lithium batteries manufactured by SAFT (not installed)
Transmitter: 2 units Receiver
Cuurent Draw
620μA T:300μA + R : 320 μA
810μA T:490μA + R : 320 μA
(at 25oC, 3.6 VDC)
(at 25oC, 3.6 VDC)
Battery Life*
Transmitter
5 Years
3 Years
Receiver
5 Years
Alarm output
Form C-Solid State Switch: 3.6VDC, 0.01A
Alarm period
2 sec (+1) nominal
D.Q. output
Form A/B-Solid State Switch: 3.6VDC, 0.01A
Low battery output
Form A/B-Solid State Switch: 3.6VDC, 0.01A (Transceiver and Receiver)
Output
**Tamper output for front cover Form 3.6VDC, 0.01A Activates when cover removed (Receiver removed)
Tamper output for back box
Form 3.6VDC, 0.01AActivates when either back box or chassis is removed
from the installment
Alarm Indicator
1) Light on - IR Beam nor received
Indicator
(Receiver)
2) Flickering Light - IR Beams not received sufficiently
3) Light off- IR Beams received
Power
Power ON: ON
(Transmitter)
Power OFF: OFF
Low Battery
Voltage reduction:Flicker
Operating Temperature
-200C - +60oC
Operating ambient humidity
95% Max
Alignment angle
+ 90o Horizontal, + 5o Vertical
Mounting
Indoor /Outdoor, Wall Pole/Tower mounting (Optional main unit mounting brackets
are required, when the units mount in the tower)
Weight
1600g (Total weight of transmitter + receiver excluding accessories)
International Protection
IP55
Specifications and design are subject to change witout prior notice *The value is based on the condition that it is used within the ambient temperature range of 20 to 25oC
** The transmitter is also equipped with AX100/200 TFR (BE)
Product Codes
AX-100TFR
AX-200TFR
LSH20
03/12
Intruder Catalogue
OPX 30m RF Twin Beam unit
OPX 60m RF Twin Beam unit
Battery for AX-TFR 3.6v 13Ah (SAFT)
Chapter 6 Page 3
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 4
Chapter 6 - Detectors Beam
Features
•
•
•
•
•
•
•
•
•
•
Active Infrared Barrier
Interior and exterior use
Self alignment system
Quick and easy to install
Small Modern and unobtrusive design
Slim line Robust aluminium housing
2 - 8 infrared beam versions
Sunlight filter
IP55 rated
EN50131 Grade 2 environment Class
GPRS Darwin Active Infra Red Barriers
Darwin is the new CIAS Active Infrared Barrier.
Manufactures with high quality aluminium it is very strong
and resistant, suitable for offsetting any expansion due to
temperature peaks. Its small size (22.5X23 mm) makes it
invisible when it is installed between window casings.
Its modularity makes Darwin perfect for use with different
protection systems, both indoor and outdoor. It is equipped
with self-alignment system, alarm LED and "Plug and Play"
Fixing system which makes it easy and quick to install the
device.
No line synchronism is required as each ray is recognised
through separate optical codes. This results in optical
Synchronism with different and unique identification codes
for each single beam. The alarm operation Logic is
managed by a micro-processor which automatically sets
the configuration of the beams as adjacent, crossed or
multiple according to ray interruption and speed of
interruption.
Darwin is available with two colours: Beside the classic
black is available the new colour aluminium, really hi tech in
the look and adaptable also to light coloured rooms.
Product Codes
616.017.100
616.017.101
616.017.102
616.017.103
616.017.104
Darwin Active Infra-red Barrier for
indoor and outdoor Use (2 beam, 0.5m)
Darwin Active Infra-red Barrier for indoor
and outdoor Use (4 beam,1m)
Darwin Active Infra-red Barrier for indoor
and outdoor Use (6 beam,1.5m)
Darwin Active Infra-red Barrier for indoor
and outdoor Use (8 beam, 2m)
GPS Darwin Beam Brackets (1x Pair).
Each pack contains a pair of brackets for
one side of the Beam unit only. You will
need 2 pairs of brackets , for 1 set of
Beams
Technical Specification
Indoor Range
Outdoor Range
Power Supply
Consumption
Dimensions (WxD mm)
Height
Tamper Output
Alarm Logic
Synchronisation
Colour
Certification
Other Function
Chapter 6 Page 4
616.017.100
12m
6m
13.8Vdc
30mA
23 x 22.5
0.5m
616.017.101
616.017.102
12m
12m
6m
6m
13.8Vdc
13.8Vdc
40mA
50mA
23 x 22.5
23 x 22.5
1.0m
1.5m
Anti-removal & anti-opening
Automatic Beam Interruption
Automatic Optical Synchronism
Aluminium
EN50131 Grade 3
Anti-Insect
Intruder Catalogue
616.017.103
12m
6m
13.8Vdc
60mA
23 x 22.5
2.0m
03/12
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 1
Chapter 7 - Detectors Glassbreak
Glass Break Detectors
Glass break detectors are used to provide early application of an attack on glass surface. There are generally two types of
detector, on glass and off glass. Off-glass detectors operate when they ‘ hear’ the frequency on breaking glass.
The advantage of this type of unit is that it can be mounted discreetly to the wall or ceiling near the window. On glass detectors
are fixed (usually with glue) to the actual surface of the window.
Features
•
•
•
•
•
•
•
•
•
•
•
•
Aritech Glass Break Detector
Unobtrusive design
2m radius protection
Easy to install
Relay alarm contact
10-15 Vdc operation
Low current
Latching alarm L.E.D.
Fail safe
No adjustment
Tamper proof
Temperature limit – 40°C to + 70°C
Waterproof
The Aritech GS 110 Glassbreak Detector has been designed
using the latest electronic techniques. This enables the
detector to contain all the necessary circuitry for excellent
detection whilst filtering out and rejecting all unwanted
signals that would normally result in a nuisance alarm(s),
e.g. ultra-sound, radio frequency interference, etc.
The Model GS 110 will operate from 10-15 vdc, providing a
2m radius of protection. Suitable for use on standard
window glass or plate glass, the GS 110 sensors detect a
frequency of150 Khz which appears when the glass is
broken.
Technical Specification
Product Codes
Power:
Alarm output:
Coverage pattern:
Environmental limits:
Dimensions:
Weight:
Colour:
Cable length:
EN5013:
03/12
10 -15 Vdc
Standby 10 mA nominal at 12 V,
Alarm 26 mA nominal at 12 V
SPST relay NC 100 mA/28 Vdc
(Fail safe)
2 metre radius
-40°C to + 70°C
28 x 28 x 12 mm
28 g
white
3.0 m
Grade 2
5443
8182
Intruder Catalogue
Aritech GS110 Piezo break glass detector
2m (radius) range
Adhesive kit for Piezo break glass detector
Coverage Pattern
Chapter 7 Page 1
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 2
Chapter 7 - Detectors Glassbreak
Features
•
•
•
•
•
•
•
250 percent better false alarm immunity
Adjustable to room size
All-new, easy-access design
Designed for quiet occupied areas on the perimeter loop
Consistent detection, even of soft, quiet glass-breaks
Detects through blinds and light drapes
End-user can test sensor operation with a clap of the
hands
• Alarm memory
Aritech Shatterproof Detector
The Aritech 5815NT-ART Series ShatterPro3™is the latest
breakthrough in Aritech’s advanced series of acoustic
glassbreak sensors. In lab tests, ShatterPro3 provides 250
percent better false alarm immunity than the popular
ShatterPro.
Using Aritech’s patented Pattern Recognition Technology,
the sensor listens for actual patterns of breaking glass while
eliminating most false alarm patterns. ShatterPro3™ listens
across the glassbreak frequency spectrum for greater false
alarm immunity.
II (GS 903N)
The coverage pattern can be easily adjusted to fit small or
large rooms. Interference outside the range will not cause
false alarms. The ShatterPro3™ detects in a full 360°
coverage pattern, with a maximum 7.6 m radius from sensor
to glass.
Available with a round or rectangular housing, ShatterPro3™
can be tested without opening the sensor by activating the
Aritech hand-held glassbreak tester at close range. A simple
hand-clap feature lets end-users confirm at any time that the
ShatterPro3™ is operational.
Technical Specification
Product Code
Input voltage:
Current:
9 to 16 Vdc
Typical 15 mA
Maximum 25 mA
Detection range:
0.9 - 7.6 m x 360°
Operating temperature: 0° to 50°C
Recommended
glass thickness:
Plate 2.4 - 6.4 mm
Tempered 3.2 - 6.4 mm
Wired 6.4 mm
Laminated 3.2 - 6.4 mm
Dimensions:
115H x 70W x 20D mm
EN50131:
Grade 2
Chapter 7 Page 2
616.008.011
Intruder Catalogue
5812EZ-W Sentrol ShatterPro3™
Rectangular Detector
03/12
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 3
Chapter 7 - Detectors Glassbreak
Features
•
•
•
•
•
•
Superior False Alarm Immunity
Glassbreak Plus Forced Entry Detection
Easy Installation
Fast, Easy and Accurate Testing
Easily Verify Detector Operation at Any Time
Field Proven Glassbreak Protection
Honeywell FG-1608T Glassbreak Detector and Magnetic Contact
The FG-1608T Series Break Glass Detectors apply Digital
Signal Processing using an on board Micro-controller to
instantly digitise sounds into mathematic sequences,
distinguishing common false alarms from breaking glass.
The digitised signal is compared against eight conditions:
Flush level threshold, audio level threshold, time
coincidence, flex/audio ratio, attack threshold, flex
duration, audio duration and microphone overload. If
these eight conditions match a glassbreak, the detector
alarms.
Technical Specification
Product Code
Dimensions:
Weight:
Range:
Mounting Locations:
Alarm Relay:
Alarm Duration:
Tamper Switch:
Power Requirements:
Glassbreak Detector: 114mm x
30mm x 23mm (h x w x d)
Magnetic Contact:
114mm x 13mm x 23mm
(h x w x d)
85g
2.4m Maximum
Mount on doors, interior window
frames, corners, walls or ceilings
Form A(NC) / 250mA @25 Vdc
5 Seconds (unaffected by alarm
LED latching)
Combination cover and wall
tamper, 25 mA @ 24 VDC
8 - 14 VDC, 17 mA typical @ 12
VDC 30 mA max. AC ripple: 4
volts peak to peak at Nominal
12VDC
5446
FlexGuard Glassbreak
Simulator/Tester
RF Immunity:
Approvals:
Type Min.
Plate
Tempered
Laminated*
Wired
Coated**
Sealed
Insulating
03/12
The sound of breaking glass is
digitally simulated by the FG-701 and
is compatible for testing all Intellisense
glassbreak detectors. Testing
glassbreak detectors upon installation
is highly recommended.
Product Code
9094
Operating Temperature:
ESD Immunity:
Glassbreak Detector and Magnetic
Contact
0°C - 49°C
10 kV; discharges of either polarity
to exposed surfaces
30 V/m, 10 MHz - 1000 MHz
Suitable for use with EN50131-1
UL Listed, PD6662 Security Grade
2 Environmental Grade II
Thickness Max.
2.4mm
3.2mm
3.2mm
6.4mm
3.2mm
Thickness
6.4mm
6.4mm
14.3mm
6.4mm
6.4mm
* 3.2mm
6.4mm
Intruder Catalogue
FG-701 Glassbreak
Simulator
Chapter 7 Page 3
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 4
Chapter 7 - Detectors Glassbreak
Features
•
•
•
•
•
•
•
•
FlexCoreTM Signal Processor
Easy Installation and Setup
Mount the Detector Anywhere
Covers All Glass Types
Multiple Domain Signal Analysis
Remote Test Mode Enable/Disable
Enclosed PC Board
Grade 3 EN50131
Honeywell FG-1625TAS Glassbreak Detector
The new FG-1625TAS Glassbreak Detector uses the latest
technology to provide faster response and increased false
alarm immunity. The FG-26TAS is designed to allow fast and
easy installation. Optimum operation can be quickly
verified using the FG-701 Glassbreak Simulator.
FlexCore™ Signal Processor
The FlexCore Signal Processor is an Application-Specific
Integrated Circuit (ASIC), which processes sound data in
parallel rather than sequentially; for faster, more accurate
detection decisions.
Technical Specification
Easy Installation and Setup Intellisense’s patented
technology allows remote activation of Test Mode
(w/simulator). The FG-1625TAS has a centred wire
entry hole, 45° terminal blocks, and EOL terminals.
A hand-clap feature verifies that the detector is functioning.
No sensitivity adjustments are required.
Product Code
Physical Dimensions: 98 mm x 62 mm x 21.8 mm
White high impact ABS plastic housing
Weight:
Product only 90 g
Pkgd. Product 116 g
Range:
15’ (4.6 m) maximum,
omni-directional
no minimum range
Alarm Relay:
FG-1625TAS
Form A, 125 mA max. 25 Vdc max.
FG-1625TAS
Form C, 125 mA max. 25 Vdc max.
Alarm Duration:
Five seconds (unaffected by alarm
LED latching)
ESD Immunity:
10kV discharges of either polarity
to exposed surfaces
Power Requirements: 6 to 18VDC; 12mA typical at
12Vdc, 22mA
max, (Latched LED) AC ripple: 4V
peak-to peak at Nominal 12Vdc
RFI Immunity:
30V/m, 10MHz to 1000MHz
Operating Temperature: -10° to 50° C
Storage:
-20° to 50° C
Chapter 7 Page 4
The combination of proven FlexGuard® performance with the
speed of FlexCore processing provides unmatched false
alarm immunity without compromising detection.
FG-1625TAS
Intruder Catalogue
FG-1625TAS Glassbreak Detector
03/12
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 5
Chapter 7 - Detectors Glassbreak
Features
•
•
•
•
•
•
•
Honeywell FG-1625Z
Only Listens for Sounds Coming from Glass
Superior False Alarm Immunity
Field Proven Glassbreak Protection
Installer Friendly Installations
Ceiling Mount Detector
Fast and Accurate Testing
Easily Verify Detector Operation at Any Time
The FG-1025Z performance is achieved through the use of 2
microphones and Time-of-Arrival (TOA) processing. When a
sound is generated in the room, the microphone nearest the
sound will hear it first. The Micro-controller in the unit
monitors all sound events received by the microphones and
processes only those received first at the ‘front’ microphone,
which is pointed toward the protected zone. Sounds arriving
at the ‘back’ microphone first are simply ignored.
Because of the symmetry of the unit, the space surrounding
the front and back microphones is divided evenly between
protected and excluded zones. A region 20 degrees wide
on each side of the unit is the keep-out zone. In this region
sound may or may not be processed. Glass to be protected
should never be within the keep-out zone. However,
false-alarm rejection is still high in this region.
Technical Specification
Product Code
Dimensions:
Glassbreak Detector:
Weight:
Range:
Mounting Locations:
Alarm Relay:
Alarm Duration:
Tamper Switch:
Power Requirements:
AC ripple:
Operating Temperature:
ESD Immunity:
5442
108mm x22.4mm x23mm (ø x d)
128g
7.6m Maximum
Ceiling
Form C(NO/NC)\125 mA @ 25
Vdc
5 Seconds (unaffected by alarm
LED latching)
Combination cover and wall
tamper,
25 mA @ 24 Vdc
8 ~ 14 Vdc, 25 mA @ 12 Vdc
4 volts peak to peak at
Nominal 12Vdc
0°C ~ 49°C
10 kV; discharges of either
polarity to exposed surfaces
FG-1625Z Break Glass Detector
Glass Type Thickness
Minimum size for all glass types is 28cm x 28cm, square.
Glass must be framed in the wall of the room or mounted
in a barrier of 0.9m minimum width.
Type Min.
Thickness Max.
Thickness
Plate
2.4mm
6.4mm
Tempered
3.2mm
6.4mm
Laminated*
3.2mm
14.3mm
Wired
6.4mm
6.4mm
Coated**
3.2mm
6.4mm
Sealed Insulating*
3.2mm
6.4mm
Coverage Pattern
Command Input/Remote
LED Enable:
Active low (0 – 1.5V). High
impedance for inputs less than
5.6 V
20 mA/16 V max.
Approvals:
UL Listed, PD6662 Security
Grade 2,
Environmental Class I
* Laminated and sealed insulating glass types are protected only if both
plates of glass are broken
** For glass coated on the inner surface with 3m scotschield type
RE35NEARL or Hard Glass Film, reduce maximum effective range to
4.6m
03/12
Intruder Catalogue
Chapter 7 Page 5
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 6
Chapter 7 - Detectors Glassbreak
This page is left intentionally blank.
Chapter 7 Page 6
Intruder Catalogue
03/12
Intruder_Ch8_SequenttialConfiDet:Layout 1 20/03/2012 10:16 Page 1
Chapter 8 - Sequential Confirmation
Sequential Confirmation Detectors
Digital Dual Technology and Combined PIR Non-Overlapping
Detectors with Anti-Masking / Blocking Technology
Features
• 15m Volumetric PIRs
• 1-15m Adjustable Microwave
• Ability to operate as TMD (Two Movement Detectors) or
TriCover®
• Interdigitated fields of view (Patent pending)
• Unique Patented Anti Masking detection
• Ability to detect masking of either PIR or Microwave
• Anti Block technology (patent pending)
• Selectable EOL (End of Line) Resistors
• 4 LED indications
• Low power consumption
• Remote LED Enable
• Active Self Test
• Low Voltage Fault Detect
Pyronix TMD-15 Sequential Confirmation Detector
The TMD 15® is a unique product boasting 2 nonoverlapping detectors; a PIR and a dual technology in 1
robust housing. Based on Pyronix’ tried and tested patented
technologies which has been proven over the last 20 years
coupled with innovative features, the TMD 15® is ideal for
use on new systems or for retro fits upgrading to
PD 6662 / EN 50131-1 Grade 3 & TS 50131-2-4.
The TMD 15® offers you outstanding detection performance
with optimum reliability designed to meet the latest industry
regulations.
Horizontal Coverage
PIR and Microwave
Volumetric
90°
30 Zone edges
3 Planes
15m
12m
174mm
PIR
Volumetric
69.3°
24 Zone edges
3 Planes
10m
8m
6m
4m
70mm
40mm
2m
15m
50ft
The 2 detectors within the TMD 15® are non-overlapping and
have separate relay outputs. These outputs signal
independently to the control panel and consequently the
ARC (Alarm Receiving Centre) in the event of an activation.
The TMD 15® enables a cost effective and efficient
sequential confirmation system.
03/12
The TMD 15® boasts an anti-masking feature, unlike other
sequential confirmation detectors currently on the market.
This means that the TMD 15® is suitable for use in high risk
environments and for use in TS 50131-2-4 / EN 50131-1 / PD
6662 Grade 3 systems.
Intruder Catalogue
Chapter 8 Page 1
Intruder_Ch8_SequenttialConfiDet:Layout 1 20/03/2012 10:16 Page 2
Chapter 8 - Sequential Confirmation
Electrical
Operating Voltage
9-16V DC (12V nominal)
Current Consumption - No Alarm State
24mA
Current Consumption - Alarm State
28mA
Relay
Solid State
Relay Output
50mA, 60V DC protected
Tamper Switch
50mA, 12V max
RFI Immunity to Continuous Wave (CW) 80-2000MHz
75V/m
RFI Immunity to Amplitude / Pulse Modulation (AM / PM)
80-2000MHz
25V/m
DTI approved frequencies
10.680, 10.687, 10.695GHz
FCC approved frequencies
10.515,10.525 10.535GHz
PTT approved frequencies
9.87, 9.90, 9.91 GHz
Operating Features
Alarm period of
2.5 secs
Detection Speed
0.2 - 3m/s
Operating Temperature
-30°C to + 70°C
Storage Temperature
-40°C to +80°C
Optical
White Light Filter
2500 Lux
Optics
Sealed
Lens
Fresnel Array ‘Grooves in’ infrared
Protection
Ultraviolet Light Filter
Mounting
Optimum Coverage Height
1.8-2.4m
Features
TriCoverTM
Applications
Triple coverage ensures that an alarm will not occur unless all
3 detectors fields are activated in a particular sequence.
Offers unparalelled stability in the elimination of false alarm
activations.
2 Independent detectors in 1 housing with non-overlapping
fields of view and separate relay outputs provide a simple
solution to sequential confirmation.
Ideal in high security environments where there may be a
significant risk of masking. An area immediately in front of the
TMD 15 TM Grade 3 is monitored continuously and separately
from its normal mode. Any intrusion into this quiet area
activates the anti masking process.
TMD (Sequential Confirmation)
Anti-Masking Detection
Product Code
TMD-15
Chapter 8 Page 2
Intruder Catalogue
Pyronix Grade 3 DualTec Sequential
Confirmation Detector 15M
03/12
Intruder_Ch8_SequenttialConfiDet:Layout 1 20/03/2012 10:16 Page 3
Chapter 8 - Sequential Confirmation Detectors
Features
• Two PIR detectors in a single housing with separate alarm
outputs
• Two non-overlapping coverage patterns
• Coverage 12m
• Active IR Anti-Mask
• Built-in Triple EOL resistors, jumper selectable
• EN50131 Grade 3 compliant
New Risco Grade 3 Sequential Confirmation PIR
The Iwise QUADSEQ G3 non-overlapping coverage patterns
and two independent alarm outputs.
Built-in Triple EOL resistors simplify installation, and active IR
anti-masking provides reliable detection of masking
attempts.
Iwise QUADSEQ G3 is designed to meet ACPO DD243:2004
requirements for sequential confirmation, and also meet
PD6662, EN 50131-1 and TS50131-2-2 Grade 3
requirements.
Coverage pattern
Top View
Side View - Center Area
Side Area
8
2.4m
6
2
4
0m
2
0m
0m
90
o
2
4
6
8
10
12m
8
10
12m
Center Area
Side View - Side Area
2
2.4m
4
2
6
0m
Side Area
8
0m
0m
2
4
6
8
2
4
6
10 12m
The Iwise QUADSEQ G3 provides a reliable solution for
installations that have to meet both Grade 3 and DD243
requirements for sequential confirmation in a single room.
When the intruder then moves to the center of the room,
the second detector triggers, providing a sequentially
confirmed alarm according to DD243 requirements.
Iwise QUADSEQ G3 contains two independent detectors
in a single housing. When mounted in the corner of a
room, one detector covers the two walls (side area), while
the second detector covers the center of the room. When
an intruder enters the room via a door or window, the side
area triggers.
03/12
Intruder Catalogue
Chapter 8 Page 3
Intruder_Ch8_SequenttialConfiDet:Layout 1 20/03/2012 10:16 Page 4
Chapter 8 - Sequential Confirmation Detectors
Technical Specification
Coverage
Variable mounting height
Intruder detection method
Anti-Masking method
Fault indication
RFI Immunity
Operating voltage
Current consumption at
Alarm, Tamper and AM contacts
Alarm time
Optical filtering for white light protection
Operating temperature
Storage temperature
Dimensions (H x W x D)
12m
2.1m to 2.7m
Two PIR sensors with separate Digital Signal Processing and relay outputs
Active infrared
Separate AM / Fault relay
30 V/m from 10MHz to 1 GHz
9-16 VDC
12VDC 12mA typical, 39mA with all 3 LEDs on
Opto-relays, N.C., 100mA, 24VDC
2.2 sec. minimum
Pigmented PIR sensor cover
-20° to 55° C
-20° to 60° C
128 x 64 x 47 mm
PD6662, EN50131-1, TS50131-2-2 Grade 3, Class II Meets DD243:2004 requirements for sequential confirmation
Product Code
RK800QST
Chapter 8 Page 4
Intruder Catalogue
Risco Iwise Grade 3 sequential
confirmation PIR
03/12
Intruder_Ch9_DetectorsDualtec:Layout 1 20/03/2012 10:18 Page 1
Chapter 9 - Detectors Dualtech
Dual Technology Detector Range
Dual Technology devices usually encompass PIR and Microwave. PIR activates on movement of warm objects against a
background level whilst microwave transmits a signal and monitors the return signal and any “new” object in front of the
device alters this signal. As PIR and Microwave detect different phenomena they are not subject to the same false alarm
sources but are equally good at detecting real alarm events.
Features
•
•
•
•
•
•
•
•
•
•
•
PIR verified by microwave module
“Step & Gliding Focus Multi-Curtain” mirror optic
Plug-in electronics
Sealed optics E
ASIC with “4D” processing
Distance of Motion microwave signal processing
Selectable range with full undercrawl detection
No adjustment required for different mounting heights
Tolerates wall angle deviation
Complies with EN50131-2-2
Several European Approvals
DD100PI Volumetric Dual Motion Sensor
The DD100 series of detectors makes no compromises
because it is a dual technology detector. It utilizes all the
good features of our PIRs, including sealed Gliding Focus
Mirrors and the latest 4D signal processing. Add to the high
quality microwave, where the latest design using Twin
Opposed Antennae has been used to ensure a better signal
to noise ratio and better microwave direction. The end
results are products with sharp detection and excellent false
alarm immunity.
The dual technology processing of this detector is very
resistant to false alarm hazards. Nevertheless avoid
potential causes of false alarms, such as:
PIR Hazards
• Direct sunlight on the detector
• Heat sources within a field of view
• Strong air draughts on the detector
• Large animals in a field of view
Microwave Hazards
• Mounting surface susceptible to vibrations
• Metal surfaces reflecting microwave energy
• Water movement through plastic pipes
• Heating or air-conditioning ducts pointed directly at the
detector
Distance of Motion (DoM) Processing
The proprietary microwave processing converts the
analogue signal into a digital one where the custom ASIC
can effectively measure the distance travelled by the
intruder, irrespective of the intruder’s speed or distance
from the detector. This gives a significantly more uniform
microwave signal over the entire protected area.
Volumetric Curtains of Detection
Benefiting from the success of the EV series PIR’s, the
DD100 also features solid curtains of detection. Full undercrawl protection gives maximum security while the special
characteristics of a “curtain” ensures not only better intruder
detection but also better PIR stability from the environment.
Product Code
Technical Specification
Detection Range
10m
Undercrawl Protection Yes
Detection Range Selection10m or 6m
Coverage Field of View 86o with 5 curtains
Coverage Pattern Selection
Undercrawl Blinder
Mounting Height
1.8m to 3.0m
Power Supply
9 to 15Vdc
Current Consumption (nom.)
11.5mA
Alarm Relay (voltage free)
NC when energised
Tamper Relay (voltage free)
NC when cover closed
Remote Control Lines Walk test
Alarm Memory
No
Microwave Frequency (nom.)
2410MHz
Dimensions (WxHxD mm)
61 x 123 x 58
Ambient Conditions
-10 to +50oC max, 95% Relative
Humidity
Pry-off Tamper
ST400 (optional)
EN50131-2-2
Grade 2
DD100PI
Dual Technology Step and Gliding Focus Multi
Curtain Mirror optics Passive Infra Red/
Microwave Detector, wide angle (86o with 5
curtains) selectable range 10m, volumetric
PIR/W motion sensor with Pet Immunity up to
20Kg
Coverage Patterns
10m
0m
10m
3.0m max
2.4 m min 0.6
10m
03/12
Intruder Catalogue
Chapter 9 Page 1
Intruder_Ch9_DetectorsDualtec:Layout 1 20/03/2012 10:18 Page 2
Chapter 9 - Detectors Dualtech
Features
•
•
•
•
•
•
•
DT900 Range
The DT900 is designed specifically for tough commercial
and industrial applications. The use of three Micro-controller
based sensitivity modes (M.A.P.TM processing) gives the
DT900 excellent detection capability while virtually
eliminating false alarms. Sensor self-adjustment ensure
reliable performance in a variety of climates and conditions.
Digital Fluorescent Light Filter
Three Micro-controller-based Sensitivity Modes
Zero Clearance Bug Guard
Small Animal immunity
Installer-Friendly Design
LED Diagnostics
EN50131 Grade 3
The DT900s long range detection pattern, vandal resistant
housing and zero clearance bug guard make it ideal for
protecting warehouses, factory floors, retail outlets, open
indoor space etc.
The DT900 Range is suitable for commercial and high risk
applications.
Detection Patterns
PIR Fields of View
DT906AM-UK - 61m Range
(2 overlapping fields of
view per PIR Finger)
Long
Intermediate long
Intermediate
Intermediate lower
Lower
Look-down
2
6
4
4
8
2
DT906AM-UK - 37 m Range
(2 overlapping fields of
view per PIR finger):
Long
Intermediate long
Intermediate
Lower
Look-down
6
4
4
8
2
DT900AM-UK - 27m Range
(2 overlapping fields of
view per PIR Finger)
Long
Intermediate long
Intermediate
Intermediate lower
Lower
Look-down
18
18
16
12
8
2
DT900AM-UK - 15 m Range
(2 overlapping fields of
view per PIR finger):
Long
Intermediate long
Intermediate
Lower
Look-down
18
16
12
8
2
Technical Specification
Product Codes
Dimensions:
Weight:
Alarm Relay:
DT900AM-UK
Tampers:
200 x 170 x 150mm
1.36kg
Energised form C: 25 VDC,
125mA
Top, wall & bottom cover
30 Vdc, 25mA (N.C.)
DT906AM-UK
DT900 Wide angle dual technology
detector, 27 metre range
DT906 Corridor dual technology detector.
61 metre range
Anti-Mask & Trouble
Relays:
NC
30 Vdc, 25mA
Power Requirements: 10.15 Vdc: 35mA (max)
Operating Temperature: 0° to 49°C, 5 % to 95% relative
humidity, non-condensing
PIR White Light
Immunity:
6500 LUX
RF Immunity:
30 V/m, 10MHz to 1000 MHz
Input 1 & 2:
Self-test initiate: Active low 0 to
1.5V,
Inactive high 5 to V+
Optional Mounting
Height Range:
2m minimum to 3.8m maximum
Microwave Frequency: X-Band
ESD Immunity:
± 10kV
EN50131
Grade 3
Chapter 9 Page 2
Intruder Catalogue
Coverage Patterns
03/12
Intruder_Ch9_DetectorsDualtec:Layout 1 20/03/2012 10:18 Page 3
Chapter 9 - Detectors Dualtech
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Dual MW & PIR Technologies
Anti-CloakTM Technology (ACTTM)
Coverage of 15m and 25m
“Green” setting - MW disabled during unset
Active IR Anti-Mask with separate relay
Built-in EOL resistors, jumper selectable
3 LED walk test indication
Cover and wall tampers
Opto-relays for low current consumption and long
lifetime
Remote and local self test
Set and LED control inputs
Creep zone
High RF immunity 30V/m
Anti-fluorescent interference signal processing
Wall tamper proof swivel (optional)
Corridor lens (optional)
Risco Iwise GreenLine DT AM
The Iwise Green Line DT AM detectors are the ultimate
motion detectors for professional installations, incorporating
both Anti-MaskTM and Anti-CloakTM Technologies
(ACTTM), adhering to new environmentally friendly
guidelines and complying with PD 6662 and EN 50131-1
Grade 3.
In response to the recent growth in environmental
awareness, Rokonet has implemented a new “Green Line”
concept in the Iwise DT AM G3 series, by effectively
eliminating surplus MW radiation during unset periods.
Iwise Green Line DT AM detectors are available in 15m and
25m models, and include built-in-end-of-line (EOL) resistors
to simplify installation.
Technical Specification
Product Codes
Coverage
15m and 25m 100o
Variable Mounting Height 2.1m to 2.7m
Intruder Detection Method Combined PIR & Microwave
with Anti-CloakTM Technology
Anti-Masking Method
Active IR
Trouble Indication
Visual & separate AM/trouble
relay
RFI Immunity
30V/m from 10MHz to 1GHz
Operating Voltage
9-16Vdc
Current Consumption @ 12Vdc
12mA typical, 39mA maximum
with all 3 LEDs on
Alarm, Tamper & AM Contacts
Opto relays, N.C., 100mA,
24Vdc
Alarm Time
2.2 sec. minimum
Optical Filtering for White Light Protection
Pigmented PIR sensor cover
Operating Temperature
-20o to 55oC
Storage Temperature
-20o to 60oC
Dimensions (HxWxD mm) 128 x 64 x 41
RK815DTG3TYB Dual Technology Passive
InfraRed/Microwave (10.587GHz)
Detector, wide angle (100o) 15m or
6m, with Antimask and Anti-Cloak
Technology, NC relay, NC relay, ADT
logo, for UK
RK825DTG3TYB Dual Technology Passive
InfraRed/Microwave (10.587GHz)
Detector, wide angle (100º) 25m,
with Antimask and Anti-Cloak
Technology, NC relay, ADT logo
RL115CV
12M Curtain Lens IWise G3
RL15VT
15m IWISE G3 Long range corridor Lens
RL17V
23m IWISE G3 Long range corridor Lens
03/12
Coverage Patterns
Intruder Catalogue
Chapter 9 Page 3
Intruder_Ch9_DetectorsDualtec:Layout 1 20/03/2012 10:18 Page 4
Chapter 9 - Detectors Dualtech
Features
• True Range Control
• 3D Signal Processing
• High Performance PIR Verified by a
‘Distance of Motion’ Technique
Aritech DD325
The DD300 Plus series are dual technology detectors based
on a high quality PIR verified by “Distance of Motion”
(DOM) measurement technique. This technique uses
ultrasonic technology to measure the distance travelled by
the target and its accuracy is not significantly affected by
the distance of the target from the detector.
The result is a family of detectors with sharp detection
characteristics and excellent rejection of traditional false
alarm sources.
Technical Specification
Product Code
Supply Voltage:
616.013.016
Current Cons:
Outputs:
Coverage:
Mounting Height:
Operating Temp:
Relative Humidity:
Dimensions:
EN50131:
Chapter 9 Page 4
10-15Vdc Max ripple 2V
peak to peak @ 12Vdc
14mA (Normal)
18mA (In alarm, LED on)
NC contacts rated, 100mA @
28Vdc
12m adj. to 5, 8, & 12m
1.8 to 2.4m
-10°C to +55°C
Less than 90%
124 x 72 x 56 mm
Grade 2
Aritech DD325 PIR/Ultrasonic Dual Tech
Detector
Coverage Patterns
Intruder Catalogue
03/12
Intruder_Ch9_DetectorsDualtec:Layout 1 20/03/2012 10:18 Page 5
Chapter 9 - Detectors Dualtech
Features
•
•
•
•
•
•
•
•
•
•
•
Dual MW & PIR technologies
Anti-CloakTM Technology
‘Green’ setting - MW disabled during unset
Active IR Anti-Mask with separate relay
Built-in EOL resistors, ampere selectable
Cover and back tampers
Opto-relays for low current consumption and long lifetime
Remote and local self test
Set and LED control inputs
Superior fluorescent interference rejection
Grade 3 Compliant
Guardtec Rokonet 360°
LuNAR Green Line DT AM detectors are the ultimate for
professional 360 ceiling mount installations, incorporating
both Anti-Mask and Anti-CloakTM Technologies (ACTTM),
adhering to new environmentally friendly guidelines.
Complies with PD6662, EN50131-1 Grade 3 and TS501312-4 requirements.
Technical Specification
Product Code
Intruder detection
Method:
Coverage:
Detection zones:
Anti-Masking method:
Temperature:
Compensation:
Trouble indication:
RFI immunity:
Operating voltage:
Current consumption
at 12Vdc:
Alarm, Tamper:
and AM contacts:
Combined PIR & Microwave
with Anti-Cloak™ Technology
13m diameter at 4m mounting
height
60 zones; 30 Fresnel segments
arranged in 3 optical levels:
12 external, 12 middle and 6
internal segments
Active Infrared
Patented True
Temperature Compensation,
Microprocessor controlled
Visual & separate AM / trouble
relay
30 V/m from 10MHz to 1GHz
9-16 Vdc
RK150DTIG3T
LuNAR Green Line DT AM Grade 3
Coverage Patterns
12mA typical, 39mA maximum
with all 3 LEDs on
Opto relays, N.C., 100mA,
24Vdc
2.2 sec. minimum
Alarm time:
Optical filtering for white
light protection:
Pigmented PIR sensor cover
Operating temperature: -20° to 55° C
Storage temperature: -20° to 60° C
Dimensions:
(Diameter x Height)
135mm x 27mm
Maximum recommended
installation height:
4m
EN50131:
Grade 3
03/12
Intruder Catalogue
Chapter 9 Page 5
Intruder_Ch9_DetectorsDualtec:Layout 1 20/03/2012 10:18 Page 6
Chapter 9 - Detectors Dualtech
Features
•
•
•
•
•
•
•
Microwave Advanced Processing (MAP)
Microwave/PIR Technology
Built-in Diagnostics and Supervision
Remote LED
Ceiling Mount Design
Micro-controller-Initiated Self-Tests
Trouble Output
DT-7360 Dual Technology Motion Sensor
The DT-7360 combines a 360 degree field of view PIR and a
unique Microwave for ceiling mounting between heights of
2, 4 and 8m. The unit can be surface or recessed mounted
The sensor is provided with the exclusive feature M.A.P.TM
processing.
Micro-controlled Advanced Processing enhances system
reliability by continuously monitoring the timing and
sequence of events required to generate an alarm
condition.
Technical Specification
Product Code
Dimensions:
130 mm x 130 mm x 60 mm
(h x w x d) White high impact
ABS plastic housing
Weight:
397 g
Power requirements:
10 – 14.5 Vdc, 40 mA typical
Microwave:
K-band
Tamper switch:
Ceiling and cover tamper
switches; Form A (N.C.) switch
rated 25 mA, 30 Vdc
Operating Temperature: -10°C – 49°C, 5% to 95%
relative humidity,
non-condensing
RFI Immunity:
30 Vm, from 10MHz - 1000
MHz
PIR White Light Immunity: 900 LUX
Approvals:
FCC certified, UL listed, DTI
approved, CE,
EN50131-1 Security Grade 2,
Environmental Class II
Detection Patterns:
PIR Fields of view
(8 - 3.4m mirror assembly)
360° fields:
Long Range:
36
Intermediate:
24
Lower:
16
Look-down:
1
(3.7 - 4.9m mirror assembly)
360° fields
Long Range:
40
Intermediate:
20
Look-down:
1
PIR Sensitivity
2 - 4 Steps within field of view
Detection range:
15m diameter, 7.6m radius
Chapter 9 Page 6
DT-7360 UK
Intruder Catalogue
C&K ceiling mount radial dual technology
detector. 15 metre diameter range
360° Dualtec
Coverage Patterns
03/12
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 1
Chapter 10 - Detectors - Passive Infra-Red
Passive Infra-Red Detector Range
The correct selection of appropriate movement detectors is fundamental to the specification of a reliable intruder detection
system. We, therefore, offer a comprehensive range of detection devices to provide the right level of protection for all
applications.
Features
• 7 curtains of protection
• 12m coverage
• ASIC with “4” processing providing improved detection
and false alarm immunity
• Additional Bi-curtain processing for harsh environments
• Precision “Gliding Focus Curtain” mirror
• True range control (Autofocus) for stable performance in
all sizes of rooms up to 12m
• Individual masking of curtains
• Remote enable/disable of walk test LED
• Selectable control polarity
• Precision “Guilding Focus Curtain” mirrors
• Sealed 4D/Bi-curtain processing
• Low current draw
EV100 Series
The EV100 series is ideally suited to small room applications
featuring solid curtains of detection, range control,
selectable bi-curtain processing for harsh environments,
sealed optics, “4D” signal processing from a custom ASIC.
The EV100 series has all major European security
Approvals.
The EV100 has been designed specially for Residential /
short range commercial applications. Details such as plug-in
electronics allow rapid wiring while the Gliding Focus
Curtains ensure that you have simple commissioning with
perfect detection every time, without the need for time
consuming alignment.
The EV100 series enables rapid installation, provides sharp
detection every time while guarenteeing excellent fasle
alarm immunity with the highest quality.
Volumatic Curtains of Detection
Benefitting from the success of the EV series PIR’s, the
EV100 also features solid curtains of detection. Full
undercrawl protection gives maximum security while the
special characeristics of a “Curtain” ensures not only better
intruder detection but also better PIR stability from the
environment.
“4D” Signal processsing
4D signal processing is the latest generation of PIR
processing taken from EV400 Plus. 4D allows the PIR
processing to intelligently analyse a signal pattern and
distinguish between real human movement and flase alarm
hazards. The PIR processing is resistant to false alarms by
analysing the size, shape and speed of successive signals.
Product Codes
EV100
Technical Specification
Detection range
10 m
Undercrawl protection
Yes
Detection range selection 10 m or 6 m
Coverage field of view
86° with 5 curtains
Coverage pattern selection Undercrawl blinder
Mounting height
1.8 to 3.0 m
Power supply
9 to 15 VDC
Current consumption (nom)4.5 mA
Alarm relay (voltage free) NC when energised
Tamper relay (voltage free) NC when cover closed
Remote control lines
Walk test
Alarm memory
No
PIR process mode
Standard / Bi-curtain
Dimensions (W x H x D)
51 x 98 x 47 mm
Ambient conditions
-10 to +55°C; 95% relative
humidity
Pry-off tamper
ST400 (optional)
EN50131-2-2
Grade 2
EV100PI
Step & Gliding Focus Multi Curtain Mirror
optics Passive Infra Red Detector, wide
angle (86o with 5 curtains) selectable
range 10m or 6m, NC relay
Step & Gliding Focus Multi Curtain Mirror
optics Passive Infra Red Detector, wide
angle (86o with 5 curtains) selectable
range 10m or 6m, NC relay, Pet Immune
version
Coverage Pattern
10m
0m
10m
3.0m max
1.8m min
10m
EV100PI Only
3.0m max
2.4m min 0.6
03/12
Intruder Catalogue
Chapter 10 Page 1
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 2
Chapter 10 - Detectors - Passive Infra-Red
Features
•
•
•
•
•
•
•
•
•
•
•
EV105 - Short Range (EV)
The EV105 has been designed specifically for short range
Commercial applications. Details such as the plug-in
electronics allow rapid wiring while the Gliding Focus
Curtains ensure that you have simple commissioning with
perfect detection every time, without the need for time
consuming alignment. The EV105 enables rapid installation,
provides sharp detection every time while guaranteeing
excellent false alarm immunity with the highest quality.
Volumetric Curtains of Detection
Benefiting from the success of the EV series PIRs, the EV105
also features solid curtains of detection. Full undercrawl
protection gives maximum security while the special
characteristics of a "curtain" ensures not only better intruder
detection but also better PIR stability from the environment.
Technical Specification
Detection range
12 m
Undercrawl protection Yes
Detection range selection
12 m or 7 m
Coverage field of view 86° with 7 curtains
Coverage pattern selection
Undercrawl blinder
Mounting height
1.8 to 3.0 m
Power supply
9 to 15 VDC
Current consumption (nom)
4.5 mA
Alarm relay (voltage free)
NC when energised
Tamper relay (voltage free)
NC when cover closed
Remote control lines
Walk test
Alarm memory
No
PIR process mode
Standard / Bi-curtain
Dimensions (W x H x D) 51 x 98 x 47 mm
Ambient conditions
-10 to +55°C; 95% relative humidity
Pry-off tamper
ST400 (optional)
EN50131-2-2
Grade 2
Chapter 10 Page 2
Passive Infra Red motion sensor
"Step & Gliding Focus Multi Cutain" mirror optic
Plug-in electronics
Sealed optics
ASIC with "4D" processing
Selectable range with full undercrawl detection
Additional bi-curtain processing for harsh environment
No adjustment required for different mounting heights
Tolerates wall angle deviation
Complies with EN50131-2-2
Several European approvals
"4D" Signal processing
4D signal processing is the latest generation of PIR
processing taken from the EV 400 Plus. 4D allows the PIR
processing to intelligently analyse a signal pattern and
distinguish between real human movement and false alarm
hazards. The PIR processing is resistant to false alarms by
analysing the size, shape and speed of successive signals.
True Range Control
The EV105 is able to adjust the PIR range. Due to the
strength of the Gliding Focus Curtain Mirror, it is possible to
reduce how hard the detector is working in smaller rooms,
making the detector even more stable, without
compromising it's excellent detection.
Accessory
A wall and ceiling mount bracket is available providing
flexibility to install and aim the detector where required.
Product Code
EV105S70
Intruder Catalogue
"Step & Gliding Focus Multi Curtain" mirror
optics passive infra red detector, wide
angle (86o with curtains) selectable range
12m or 7m, NC relay
Coverage Patterns
03/12
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 3
Chapter 10 - Detectors - Passive Infra-Red
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Passive Infra Red motion sensor
Tri-Brid Step & Gliding Focus Curtain mirror
Plug-in electronics
Sealed optics
"5D" signal processing for false alarm immunity
Cloak and umbrella immunity
Full under crawl detection
Selectable coverage pattern using mirror masks
Auto focus with constant range sensitivity
No adjustment required for different mounting heights
Tolerates wall angle deviation
Certified EN50131-2-2 Grade 2 and 3
Several European approvals
EV1116 - Regular Range (EV)
GE Security motion sensors have the most advanced and
sophisticated optics in the security industry. This unique
optical mirror technology is a step and gliding focus, which
creates a continuous curtain resulting in a sensor that never
loses track of the object.
To increase detection coverage, the EV1100 series sensors
incorporate a 3-step gliding focus, which produces 11
continuous curtains to detect infrared signals up to a 16m
distance.
When a slow thermal source is detected, the signal
processing switches automatically to the 5D mode and
executes additional pattern recognition to distinct this signal
from a slow walking person. If the signal fits, it must be an
intruder and an alarm is generated. If there is no fit, the
signal is ignored, which ensures signals such as moving
reflection of sunlight are filtered out.
The result is a unique combination of high sensitivity
detection with high false alarm immunity without the need
for manual sensitivity adjustment.
5D" is the next generation of GE Security signal processing.
It builds on the current strengths of 4D, but adds an
intelligent differentiation between fast and slow moving
signals.
Technical Specification
Product Codes
Detection range
16 m
Undercrawl protection
Yes
Sensitivity
Normal / High
Coverage field of view
86° with 11 curtains
Coverage pattern selection Curtain labels
Mounting height
1.8 to 3.0 m
Power supply
9 to 15 VDC
Current consumption (nom.)
4.1 mA (EV1116)
11 mA (EV1116AM)
Alarm relay (voltage free) NC when energised
Tamper relay (voltage free) NC when cover closed
Remote control lines
Walk test
Alarm memory
Yes
PIR signal processing
5D
Dimensions (W x H x D)
125 x 65 x 60 mm
Ambient conditions
-10 to +55°C; 95% relative
humidity
Pry-off tamper
Optional
EN50131-2-2
Grade 2 (EV1116S70)
Grade 3 (EV1116AMS70)
EV1116S70
03/12
EV1116AMS70
"Tri-Brid Step & Gliding Focus Multi
Curtain" mirror optics passive infra red
detector, wide angle (86o with 11 curtains)
selectable range up to 16m, NC relay.
EN Grade 2
"Tri-Brid Step & Gliding Focus Multi
Curtain" mirror optics passive infrared
detector, wide angle (86º with 11 curtains)
selectable range up to16m, NC relay, with
antimask. ENGrade 3
Coverage Pattern
Intruder Catalogue
Chapter 10 Page 3
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 4
Chapter 10 - Detectors - Passive Infra-Red
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
VE1120 - Long Range (VE)
GE Security motion sensors have the most advanced and
sophisticated optics in the security industry. This unique
optical mirror technology is a step and gliding focus, which
creates a continuous curtain resulting in a sensor that never
loses track of the object.
Passive Infra Red motion sensor
Tri-Brid Step & Gliding Focus Curtain mirror
Plug-in electronics
Sealed optics
"V2E" signal processing for false alarm immunity
Cloak and umbrella immunity
Full under crawl detection
Selectable coverage pattern using mirror masks
Auto focus with constant range sensitivity
No adjustment required for different mounting heights
Tolerates wall angle deviation
Complies with EN50131-2-2 Grade 2 and 3
Several European approvals
Infrared signals are captured by the pyro-electric sensor
that is placed in the detectors' focal point. The conventional
pyro generates a one-dimensional signal (value) to detect
the presence of a source, and therefore its detection
probability within the area is entirely determined by the
resolution of the optics of the motion detector.
To increase detection coverage, the VE1120 series sensors
incorporate a 3-step gliding focus, which produces 11
continuous curtains to detect infrared signals up to a 20m
distance.
Technical Specification
Detection range
20 m
Undercrawl protection
Yes
Sensitivity
Normal / High
Coverage field of view
86° with 11 curtains
Coverage pattern selection Curtain labels
Mounting height
1.8 to 3.0 m (6 to 10 ft)
Power supply
9 to 15 VDC
Current consumption (nom)4.4 mA
Alarm relay (voltage free) NC when energised
Tamper relay (voltage free) NC when cover closed
Remote control lines
Walk test
Alarm memory
Yes
PIR signal processing
V2E
Dimensions (W x H x D)
125 x 65 x 60 mm
Ambient conditions
-10 to +55°C; 95% relative
humidity
Pry-off tamper
Optional
EN50131-2-2
Grade 2 and 3
Chapter 10 Page 4
Product Codes
VE1120S70
VE1120AMS70
"Tri-Brid Step & Gliding Focus Multi
Curtain" mirror optics passive infra
red detector, with "V2E" signal
processing for false alarm immunity,
wide angle (86o with 11 curtains)
selectable range up to 20m, NC relay
"Tri-Brid Step & Gliding Focus Multi
Curtain" mirror optics passive infra
red detector, with "V2E" signal
processing for false alarm immunity,
wide angle (86o with 11 curtains)
selectable range up to 20m, NC
relay, antimask
Coverage Pattern
Intruder Catalogue
03/12
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 5
Chapter 10 - Detectors - Passive Infra-Red
Features
•
•
•
•
•
•
•
•
•
•
•
•
•
Passive Infra Red motion sensor
Multi channel Anti Masking for all masking attempt
High density "Step & Gliding Focus" Multi Curtain mirror
Plug-in electronics
Sealed optics
"Vector Verified Enhanced" detection algorithm
Selectable range with full undercrawl detection
Selectable AM reporting and resetting
3 alarm sensitivities
No adjustment required for different mounting heights
Tolerates wall angle deviation
Pry-off and cover tamper
Complies with EN50131-2-2 Grade 2 and 3 versions
VE735 - Long Range (VE)
With the “High Density Optic” (HDO) mirror the VE735 will
provide you with more and wider curtains (and therefore
untraceable detection gaps), without increasing the mirror
size. The VE735 has a comprehensive floor pattern, made
by a wide angle mirror featuring 11 high density curtains
over a 90o field of view, enhanced with a 60m long range
curtain.
The VE735 is the only motion detector on the market that
can offer this unique protection in one product.
The pattern of the output vector of the VE735 pyro contains
unique information about the origin of the source. That’s
why the DSP in the VE735 can recognise the dircetion in
which the thermal source is moving. In other words, the
VE735 allows you to determine the dircetion of the intruder
across the surveillance area. When the chime mode is ON,
the VE735 can trigger an alarm when an intruder walks from
left to right and differentiate intruder movement from right to
left and vice versa.
Optics
The optical part of the VE735AM is identical to the VE735.
The step & glide focus mirror with multi curtains are features
unique to GE Security to provide maximum coverage
density and ensure easy installation.
Patented multi channel Anti-Masking
It is known that the best solution to protect a motion sensor
from being masked is active IR technology. GE Security has
always served the market with the best available technology
to achieve the highest AM performance. The VE735AM
continues this trend by using the fourth generation of AM.
EN50131-2-2 Grade3 compliancy
The VE735AM is designed and approved to comply with
EN50131-2-2 Grade 3, as well as with all highest European
security grades for a PIR/AM motion sensor.
The VE735AM is another GE Security motion sensor using
the V2E technology. This product uses the PIR part of VE735
together with multi channel anti masking.
Technical Specification
Detection range
60 m
Undercrawl protection
Yes
Detection range selection 60 m or 20 m
Coverage field of view
86°, 11 curtains & 5°, 1 curtain
Coverage pattern selection Blinders and curtain labels
Mounting height
1.8 to 3.0 m
Power supply
9 to 15 VDC
Current consumption (nom) 11mA G2 & 20mA G3
Alarm relay (voltage free) NC when energised
Tamper relay (voltage free) NC when cover closed
AM relay (voltage free)
NC when no AM
Relay configuration
Isolated or 4k7 EOL
Remote control lines
Walk test & Day-Night
Alarm memory
Yes
PIR process mode
Low / Standard / High
Dimensions (W x H x D)
93 x 175 x 66 mm
Ambient conditions
-10 to +55°C; 95% relative
humidity
Pry-off tamper
Yes
EN50131-2-2
Grade 2 and 3
03/12
Product Codes
VE735S70
VE735AMS70
Intruder Catalogue
"Step & Gliding Focus Multi Curtain" mirror
optics passive infra red detector, with
"V2E" signal processing for false alarm
immunity, wide angle (86o with 11 curtains
or 5o with 1 curtain) selectable range 60m
or 20m, NC relay....EN Grade 2.
"Step & Gliding Focus Multi Curtain" mirror
optics passive infra red detector, with
"V2E" signal processing for false alarm
immunity, wide angle (86o with 11 curtains
or 5o with 1 curtain) selectable range 60m
or 20m, NC relay, antimask....EN Grade 3.
Coverage Pattern
Chapter 10 Page 5
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 6
Chapter 10 - Detectors - Passive Infra-Red
Features
• Compatible with Domonial, Galaxy and Vista radio
modules, the IR8M & IRPI8M reduce the number of PIRs
you need to have in stock
• Four levels of sensitivity can be adjusted by switches,
make the IR8M perfect for a wide range of installations
• The IR8M & IRPI8M sensors mount virtually anywhere –
on walls, in corners or on ceilings
• Furthermore with the same attractive housing as the wired
IntelliSense IS2500 family, they allow a uniform look on
hybrid installations
• The two different lenses supplied with the IRPI8M (Pet
immune and high security) combined with four levels of
sensitivity which can be adjusted by a switch, make it
perfect for a wide range of installations.
• Compliant to latest European 2.7GHz EMC requirement
(mandatory for CE compliancy)
• Compliant with EN50131 rev. 2008
• Corner mount bracket (note: wall mount bracket was
already included)
• Protected PCB for PI version.
IR8M & IRPI8M
The IR8M & IRPI8M are the new universal wireless infrared
sensors from Honeywell. These PIRs have all the benefits of
our existing range of Infrared sensors and wireless
peripherals.
Features of the IR8M include, compliance to TS EN50131-22 Grade 2, Class II, providing exceptional detection
capabilities.
Features of the IRPI8M include selectable immunity for
animals weighing up to 36Kg, compliance to TS EN50131-22 Grade 2, Class II, providing exceptional detection
capabilities.
Product Codes
IR8M
IRPI8M
Chapter 10 Page 6
Intruder Catalogue
Universal Wireless Passive Infra Red
Detector
Universal Wireless Passive Infra Red
Detector including pet immunity up to
36Kg
03/12
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 7
Chapter 10 - Detectors - Passive Infra-Red
Technical Specification
Detection range
11 x 12m (at 2,30m mounting
height) Look-down pattern for
Hi-Security applications
Pet Immunity (IRPI8M)
Switch selectable pet immunity
0, 18 or 36Kg
Tamper Switch
Front cover and back
Lens (IR8M)
Hi-Security lens
Lenses (IRPI8M)
Pet Immune lens (factory
mounted)
Optional Hi-Security lens
(provided)
White light immunity
>6500 lux
Sensitivity & Pulse count
Switch selectable – Lowest,
Low, Medium, High
LED
Switch enabled Indicates
detection and transmission
(different timing)
Operating temperature
-10oC to 55oC
Relative humidity
5% to 95%, non-condensing
Storage temperature
-20oC to 70oC
Temperature compensation Advanced Dual Slope
Temperature Compensation
Test mode
Started at tamper opening and
closure 10mn duration
Dimensions
11, 2 x 6 x 4cm
Weight without battery
84g
Includes (IR8M)
Lens masking, Battery
Includes (IRPI8M)
Lens masking (PI and
Hi-security) Lookdown mask for
pet immune applications
(neoprene rubber) High
Security lens
Battery
One 3V CR123 lithium
Battery life
> 4, 5 years (> 3 years on
Galaxy or Vista radio modules)
Radio
Dual-protocols: V2 GY and
Alpha, FM narrow band,
868MHz frequency, 2000m
range in open field, Supervision
Compatibility
Galaxy Radio module: RF-Portal
(C077) Vista Radio module:
5882EUHSDomonial: CMI
800++ panels from I version
onwards
Approvals
EN50131-1 and TS50131-2-2
Security Grade 2,
Environmental Class II (IR8M)
Grade 2, Environmental Class II
(with high-security lens
mounted) (IRPI8M)
03/12
Intruder Catalogue
Coverage Pattern
Side View
Chapter 10 Page 7
Intruder_ch10_DetectorsPir:Layout 1 20/03/2012 10:19 Page 8
Chapter 10 - Detectors - Passive Infra-Red
Features
•
•
•
•
•
•
•
360° coverage
Full undercrawl detection
20m range (diameter)
2 x pyros; 2 x mirrors; 2 x ASICs; 2 x performance
18 unique gliding focus curtains
Precision mirror optics
Latest generation ‘4D’ signal processing providing
increased environmental stability with enhanced detection
capability
• Electronic coverage pattern selection
• Alarm memory as standard
• Selectable control logic for alarm memory and walk
test LED
EV669 - Short Range (EV)
With 18 curtains the EV669 offers a maximum detection
capability throughout the protected area including full
undercrawl detection.
In order to ensure the highest performance, the EV669
incorporates 2 x pyros, 2 x ACIS,s and 2 x the decision
power providing the installer/user with 2 x the performance.
Technical Specification
Product Code
Supply voltage:
Current consumption:
Normal operation
In alarm, LED on
Outputs:
Alarm:
Tamper:
Mounting height:
Coverage:
Ambient conditions:
IP rating:
Dimensions:
EN50131
Chapter 10 Page 8
8 - 15 Vdc; Max. ripple 2 V
peak-to-peak at 12 V dc
616.013.019
Aritech EV669 20m diameter Radial PIR.
Ceiling Mount
6 mA (EV 669)
11 mA max.
NC 100 mA at 28 Vdc.
Voltage free relay
100 mA at 28 Vdc
2.5 to 5.0 m
10 m radius
-18° to +55°C; Max 93% relative
humidity
IP301
Ø 138 x 66 mm
Grade 2
Intruder Catalogue
Coverage Pattern
03/12
Intruder_Ch11_DetectorVibration:Layout 1 20/03/2012 10:21 Page 1
Chapter 11 - Detectors - Vibration
Vault, Safe & ATM Protection Including Vibration Sensors
Vibration detectors are used to protect against physical attack on the fabric of a building or room. Special application
devices are available to protect vaults, strongrooms and Automated Teller Machines (ATM’s).
Seismic Detectors
Features
• Able to detect attempted break-in before entry
to the premises
• Unique Bi-Coloured LED indication of minor
or gross attack
• Shockguard 2 will monitor for minor vibrations
(and count them to a preset limit) and for major attacks at
the same time
• Choice of colour to suit different backgrounds
• Full anti-tamper protection
• Electronics module protected from moisture
• Each unit has it's own analyser with custom integrated
circuit that enables individual adjustment of all units
• High immunity to low frequency false alarms
• High immunity to radio interference
• Meets the requirements of BS 4737
• Compatible with all makes of control panels
Shockguard-2T
The Shockguard range of seismic detectors are able to
differentiate between natural vibrations that occur in our
environment and those that would only occur from an illegal
entry. Each detector has it's own analyser built-in. At the
heart of this analyser is a custom integrated circuit that is
exclusive to Gardiner Technology. All Shockguard versions
are designed to meet the requirements of BS 4737.
Quality and reliability are factors that are built in to the
Shockguard range. The housing is raised slightly to prevent
condensation entering the unit and each circuit board is
individually coated with a moisture proof coating.
Product Codes
616.006.010
616.006.011
616.006.012
03/12
Intruder Catalogue
Shockguard-2T Vibration Sensor (White)
Shockguard-2T Vibration Sensor (Brown)
Shockguard Metal Box - White
Chapter 11 Page 1
Intruder_Ch11_DetectorVibration:Layout 1 20/03/2012 10:21 Page 2
Chapter 11 - Detectors - Vibration
Features
• Tri-colour LED enables accurate and reliable calibration,
with ‘over-sensitive’ and ‘under-sensitive’ indications
• Internal magnetic reed switches for double protection
(shock and contact) saves installation time and cost
• Magnet can be mounted on the right side of the detector
up to a 20mm gap
• Mounts on frame or glass, vertically or horizontally
• Dual stage adjustment potentiometer
• Encapsulated piezo-electric sensor
• Cover tamper protection
• Modern design with ample wiring space and hermetic
wiring seal
• Magnetic Interface
• Grade 3
ShockTecTM
ShockTecTM digital shock detectors provide reliable
24hour perimeter protection. A break-in is detected as soon
as the intruder attempts to force, smash, drill or even saw
through the protected window, door, wall or roof. This
means that the alarm is activated whilst the intruder is still
outside, minimising damage to the premises and its
contents, and maximising personal security.
The DSP methods include analysis of signal frequency,
energy, amplitude and duration.
The ShockTecTM has optional magnetic reed switches for
double protection on opening windows and doors. The
detector may be mounted vertically or horizontally, with the
magnetic contact on either side of the detector.
ShockTecTM detects gross attacks and provides an
exceptional level of discrimination between real attacks
and background vibrations. An advanced digital
microprocessor with Intelligent Digital Signal Processing
accurately analyses the vibration signal from the
piezo-electric sensor.
Any attempt to defeat the detector by using large magnets,
as defined by EN-50131 Security Grade 3 requirements, will
cause a tamper signal.
Technical Specification
Typical Detection Range
An exceptional level of discrimination between real attacks
and vibrations caused by regular activities is achieved by
analysing the event parameters.
ShockTecTM with Magnetic Contacts
Supply voltage:
9V –16V DC
Current consumption
(typical):
12.5 mA 7.5 mA
Operational temp:
-200C to 600C
Maximum humidity:
95% non-condensing
Sensitivity setting:
Dual stage potentiometer
Tri-colour LED indicator:
Orange: Over-sensitive
Green: Alarm & correct calibration
Red: Under-sensitive
Contact ratings:
Alarm relay:
100mA at 24VDC, NC 100mA at
24VDC, NC, Opto relay
Tamper relay:
500mA at 24VDC, NC 500mA at
24VDC, NC
Reed relay:
100mA at 24VDC, NC
Alarm time:
2.5 seconds
Magnetic contact
reed relay option:
Two reed relays enable locating
the magnet on either side of the
detector
Latching modes:
Any or 1st to latch operation
modes
Max no. of units on
Any Latch loop:
80
Max no. of units on 1st
to Latch loop:
10
False alarm protection: Digital microprocessor signal
processing and noise reduction
with maximum ground plane
Electrostatic discharge: No false alarms up to 8kV
RF immunity:
40 V/m from 80MHz to 1GHz
Enclosure material:
Flame retardant ABS
Enclosure dimensions: 25x28x95mm 25x28x95mm –
detector 0.98x1.1x3.74 inch
0.98x1.1x3.74 inch
10x12x58mm – magnet
0.39x0.47x2.28 inch
Chapter 11 Page 2
Surface Radius
Concrete
Brick Wall
Steel
Glass
Wood
Plywood
1.5m
2.5m
3m
3.5m
3.5m
4m
Product Codes
RK601SMT
RK601SMBT
Intruder Catalogue
Grade 3 Shocktec Plus White
Grade 3 Shocktec Plus Brown
03/12
Intruder_Ch11_DetectorVibration:Layout 1 20/03/2012 10:21 Page 3
Chapter 11 - Detectors - Vibration
Features
•
•
•
•
Internal Heat Detector
High Security
Simple Installation and Calibration
High Rejection of False Triggers
Elmdene 5169 Safe Limpet with Delay
The Limpet Set is designed for the protection of safes, filing
cabinets, fruit machines etc. and may be fitted to any article
or piece of equipment that has a ferrous exterior. The
selective vibration detector is designed to trigger an alarm if
any attempt is made to gain access to the protected
equipment by hammering, drilling, chiselling etc. The heat
detector contact opens at a nominal temperature of 60° and
gives protection against attacks by thermal cutting
techniques.
The keep reed switch, which is held in the closed circuit
position by the keep magnet, becomes open circuit when
the limpet is removed from the keep, and thus trigger the
alarm if any attempt is made to remove the limpet from the
keep. In this sense it acts as a proximity switch.The second
reed switch is opened by the presence of an external
magnet. This eliminates the possibility of an external
magnet being used to override the keep magnet reed
switch.
Technical Specification
Product Code
Dimensions:
Weight:
120H x 95W x 35D mm
(Limpet)
130H x 105W x 30D mm
(Keep)
Limpet - 356g
Keep - 136g
616.013.028
Safe Limpet with delay
The Limpet will enter its alarm condition when either of the
conditions below are met:
a. Any of the reed or tamper switches are opened
b. The internal temperature rises above 60°
c. An impact or vibration triggers the Vibration Detector
03/12
Intruder Catalogue
Chapter 11 Page 3
Intruder_Ch11_DetectorVibration:Layout 1 20/03/2012 10:21 Page 4
Chapter 11 - Detectors - Vibration
Features
• Detects all known methods of attacks
• Advanced signal processing differentiates between
ambient noise and real attacks
• Draws extremely low current
• Two options of testing
• Adjustable sensitivity
• Full-scale tamer protection
• Complete line of accessories
• Easy to install
Seismic Detectors
The Advisor X series of vault sensors and accessories
provide early warning of attack on high security risks such
as bank vaults, night deposit safes, data storage rooms,
bonded areas etc.
The VV600 seismic detector senses vibrations that occur
within a radius of up to a maximum of 14m, dependent on
the surface to which it is fixed and the method of attack.
The VV600 is unique in having three distinct detection
channels allowing it to be highly tuned to detect the
frequencies known to be present during an attack. At the
same time it is able to reject everyday frequencies occurring
due to ambient movement and building settlement. The
result is excellent, secure detection without false alarm
problems. All this is possible in a small unobtrusive detector
due to the application of sophisticated technology and
miniature components.
VV602 Seismic Detector
The VV602 Seismic detector is specially designed to protect
automatic cash dispensers and night safes. The
sophisticated combination of three detection channels
allows the VV602 to detect all forms of attack, whilst not
responding to the vibrations arising from normal operation.
VM600 Mounting Plate
The Advisor X system includes a wide range of accessories,
allowing it to be installed easily and adding extra elements
of security. The VM600 allows easy mounting of the
detectors on concrete walls.
Technical Specification
Dimensions:
100H x 80W x 30D mm
Product Codes
Supply Voltage:
External dc power source
9 - 15Vdc, 2V max ripple
peak to peak
Typical 24mA
5470
616.013.020
617.001.047
5425
616.013.046
Power:
Chapter 11 Page 4
5423
Intruder Catalogue
Aritech VV600 Seismic detector. 1-4m
(radius) Range
Aritech VM653 5mm spacer
Aritech VV602S25 Seismic Detector
Aritech VM600 Mounting Plate
Aritech VM652 Keyhole Flap
Aritech VM654 Armed Cable Kit
03/12
Intruder_Ch12_DetectorsTemp:Layout 1 20/03/2012 10:22 Page 1
Chapter 12 - Detectors - Temperature
Temperature Sensors
Features
•
•
•
•
•
•
•
Program output for NO or NC operation
Programmable time-delay alarm output (0-255min.)
Accurate to ± 1.7°C (± 2.2°C without the probe)
Operates from -40°C to 60°C (0°C without the probe)
Push button programmability
Farenheit or Celsius operation
Standard remote probe is water resistant/weather
resistant
• Mount remote probe up to 100M from unit (purchase
separately)
Temperature Sensor
The TS300 is a hardwired temperature monitor able to
accurately detect variations in temperature. It can monitor
the temperature at the unit and at a remote location (using a
T280R) simultaneously. Alarm annunciations include a local
piezo sounder and two programmable NO/NC outputs
which activate when the mapped high or the low limits(S)
are exceeded, protecting equipment, property, and
perishable items.
The NO/NC alarm outputs may be delayed by increments of
one minute to allow for expected momentary temperature
variations such as during a refrigeration unit’s defrost cycle.
The audible alert, if programmed sounds when the
temperature limit is violated can be silenced with the press
of a button for a programmed duration.
Technical Specification
Product Codes
TS300
Set Point
programming method:
Set point/detection
range:
Min. span between high
and low set points:
Temperature accuracy:
Temperature response
time:
Indicators:
TS300
T280R
Temperature Alarm
Remote Probe for use with TS300 sensor
High/Low set point; digitally
programmed
40°C to 60°C
2.2°C
±1.7°C
1.1°C per minute
Seven segment LED
display: High/Low alarm,
ambient temperature
I7 to 16VDC
Input voltage:
10mA
Max current:
Selectable No/NC 50mA max.
Alarm output:
at 30 VDC
Operating temperature: 0°C to 60°C
118 x 78 x 29mm
Dimension (HxWxD):
T280 Remote Probe:
Temperature accuracy:
Temperature response
time:
Operating Temperature:
Dimensions:
03/12
±2.2°C
1.1°C per minute
-40°C- 60°C
9.5mm diameter x 38mm
L; cable:4.6m L
Intruder Catalogue
Chapter 12 Page 1
Intruder_Ch13_ExtlLightng:Layout 1 20/03/2012 10:23 Page 1
Chapter 13 - External Lighting Control
External Lighting Control
This new controller features a Modern blue back-lit LCD display showing real time clock, detector activation and zone
status. In addition to the controller a new 4 zone expander unit with built in energy efficient switch mode, 1amp 12v psu,
which can switch up to 6000 watts and is IP65 rated.
Features
•
•
•
•
•
Precise 24 hour control and monitoring
User-friendly control panel
Modern LCD display
2 programmable timers for each zone
Expanded to enable up to 30,000 Watts of lighting
GJD DygiZone External Lighting Controller
The Advanced Multi-function, 4 zone, security lighting
controller & enunciator, that saves power, minimises light
pollution and enhances security.
In an effort to increase security, many houses and premises
are lit up like a Christmas tree at night. Instead of deterring
intruders, some of these security lighting systems just light
their way, whilst at the same time illuminating the sky and
wasting energy.
The new advanced, feature rich DygiZone Controller
provides intelligent security lighting control which enhances
security, saves energy and minimises light pollution with
features such as • Precise 24 hour control and monitoring of 4 zones of
security lighting via a user-friendly control panel and
modern LCD display.
• Programmable functions that accurately control the
activation, timing and duration of the lighting to minimise
energy consumption and light pollution.
• Any one of 5 mode settings can be programmed for each
zone.
• When the external GJD sensors are activated, the
DygiZone indicates which Zone has been activated by
either an audible beep or a 10 second pre-recordable
voice message - and the Zone indicator is illuminated on
the control panel.
• 2 programmable timers for each zone allows the lighting
to be automatically switched on & off at pre-set periods
for a pre-set time-ideal for when a building or premises
are unoccupied.
• A system override can be made from up to 3 locations at
any time.
• The system can be expanded to enable up to 30,000
Watts of lighting to be controlled and switched as
required.
Product Code
GJD910
GJD 4 zone LCD Dygizone controller
Technical Specification
Display
Audible Warnings
Control
System configuration
Time control
Modes
Pulse Count
Maximum Wattage
Mounting
Temperature
Dimensions
Supply
Weight
Modern blue back-lit LCD display showing real-time clock (12 or 24 hours), detector activation and
Zone status
Internal warning beep with individual tones available for each Zone or a different 10 second voice
message can be recorded for each Zone
Four individual Zone buttons for selecting Zone status and programming options Keypad lockable
to preventaccidental changes to programme or settings
Normally - 1 Master and 1 Slave DygiZone
One additional Slave can be added if required
Requires GJD Expansion Units
Two individual on/off timers per Zone with ‘lights-on’ time adjustable for 1,2,3,4,5,8,12,16 or 24
minutes
Up to 5 different Modes can be selected for each Zone
The sensitivity of the detectors selectable as 1,2 or 3
Up to a total of 30, 000 Watts of lighting can be controlled and programmed across the 4 Zones
For indoor use only. Mount in a clean dry location. Can be fitted to a standard single or double
flush backbox
-100C to +550C
134 ( W ) x 87 ( H ) x 30 ( D ) mm
12 VDC @ 20 mA standby. 100 mA triggered with message playback
190g NET, 260g GROSS
The DygiZone is compatible with GJD Expansion Units and is designed as a direct replacement for Solitaire keypads
03/12
Intruder Catalogue
Chapter 13 Page 1
Intruder_Ch13_ExtlLightng:Layout 1 20/03/2012 10:23 Page 2
Chapter 13 - External Lighting Control
Features
The mini Opal, which replaces the existing unit, is an
attractively styled, 30 metre Passive Infrared (PIR) detector
that works with GJD security lighting controllers. The mini
Opal has additional advanced PIR features as follows:
GJD Mini Opal - 30 metre External PIR
• Sensor mounted white-light filter (sun glasses) to prevent
false detections on sunny days
• Dual tamper switches for case and wall-mount tamper
detection
• Zone blanking using vertical curtains and horizontal foil
for precise area coverage
• ±90° horizontal and ±45° vertical aim adjustment
• Conformally coated electronics for enhanced UV and
moisture resilience
• Attractive, 21st century styling with a protective cover to
disguise sensor direction.
Technical Specification
Coverage (max)
90° at 30m, equivalent to 625m2
Reach
Adjustable 9m to 30m
Directional adjustment ±90° horizontal (180°), ±45° vertical (90°)
Area adjustment (blanking)
Supplied with, 1 foil label for near/far beam blanking and 4 vertical opaque curtains for zone
blanking
Lens
2 rows of 10 beams
Sensor
White light filter prevents false triggering when sunny
Output A (Alarm)
Open-collector transistor switch. 12V, 25mA alarm current
Output S (Sensor, daylight)
Open-collector transistor switch. 12V, 25mA alarm current
Output T (Tamper)
Volts-free, normally-open switch output
Tamper switches
Case open and removal from wall
Power
9 to 15V DC
Current
4mA at 12V
Operating Temperature -20°C to +55°C
Protection
IP55, high-impact ABS housing. Conformal coated electronics (moisture and UV protection
lacquer)
Dimensions
84 x 106 x 72 mm
Mounting
Suggested height 3m
Cabling
0 to 200m: standard, 4-core, 7/0.2mm alarm cable 200 to 500m: 8-core, 16/0.2mm (use double
cores)
Approvals
The manufacturer declares that the product supplied is compliant with the provisions of the EMC Directive 89/336/EEC
amended 92/31/EEC for Electromagnetic Compatibility, and the Restriction of Hazardous Substances Directive (RoHS)
2002/95/EC. A Declaration of Conformity in accordance with the above directives is held on file with the manufacturer.
Product Code
GJD332
Chapter 13 Page 2
Intruder Catalogue
GJD Mini Opal 30m sensor
03/12
Intruder_Ch13_ExtlLightng:Layout 1 20/03/2012 10:23 Page 3
Chapter 13 - External Lighting Control
GJD 4 Zone Expansion Unit
The 4 Zone Expansion Unit works in conjunction with
DigiZone lighting controllers, Solitaire Touch Controls and
GJD detection devices. The modular design enables the 4
Zone Expansion Unit to be conveniently installed within
easy access to the mains supply.
The low voltage cable link allows the DygiZone lighting
controllers, Solitaire Touch Controls and Expansion Units to
be positioned anywhere up to a distance of 200 meters.
Technical Specification
Product Code
Mains Supply Input
GJD040
2 x 230 VAC 50 HZ via RCD, MCD
and 13 AMP fused spurs
Lighting outputs Driven 4 x 230 VAC 50 HZ 1500 Watts
Maximum or 1000
watts ballast
12 VDC Output
12VDC @ 1Amp
Operating Temperature -10o to 50o
Weight
810 gms
Dimensions
210 x 180 x 79mm
Mounting
Mount in a clean dry location on a
secure flat surface
GJD 4 Zone Expansion unit with 1amp
switch mode psu
Class 2 Independently mounted control EMC directive
2004/180/EC
GJD Sapphire 1 Zone Controller
An attractive single zone multi-sensor security lighting
controller utilises external sensors day and night. At dusk
on detection from up to 8 sensor lights are switched
automatically for a selected timed period. Lighting up to
1500W can be switched manually when required. It features
a 24 hour controllable audible warning tone and 4 detection
indicators plus added flexibility of a remote sounder output,
walk test facility, and pulse count adjustment and an
optional easy link to a standard alarm panel for instant light
activation under alarm conditions.
Technical Specification
Product Code
Dimensions
Supply Voltage
Power
6577
85H x 146W x 56D mm
230Vac
1 x 1500W
GJD Sapphire 1 zone controller
GJD Solitaire 2 zone expansion unit
Technical Specification
Product Code
Dimensions
(Controllers)
(Expansion Unit)
Supply Voltage
Power
(Expansion Unit)
6579
03/12
85H x 146W x 20D mm
85H x 146W x 48D mm
GJD Solitaire 2 zone expansion unit
230Vac
2 x 1500W
Intruder Catalogue
Chapter 13 Page 3
Intruder_Ch13_ExtlLightng:Layout 1 20/03/2012 10:23 Page 4
Chapter 13 - External Lighting Control
The unit utilises a passive infrared technology to detect heat
radiation of moving human bodies. Upon detection, the
lamp will illuminate for a user-determined time period. An
integral daylight sensor ensures night-only operation. The
motion detector has a number of detection zones, at
various vertical angles.
A moving human body needs to cross/enter one of these
zones to activate the sensor. The best all-round coverage is
achieved with the unit mounted at the optimum height of
2.5m.
• Fully enclosed unit
• Easy setup
External PIR’s Lighting
Technical Specification
Product Codes
Mains Supply Input
8162N
8164N
5396
2 x 230 VAC 50 HZ via RCD, MCD
and 13 AMP fused spurs
Lighting outputs Driven 4 x 230 VAC 50 HZ 1500 Watts
Maximum or 1000
watts ballast
12 VDC Output
12VDC @ 1Amp
Operating Temperature -10o to 50o
Weight
810 gms
Dimensions
210 x 180 x 79mm
Mounting
Mount in a clean dry location on a
secure flat surface
Enclose 400w halogen fitting
330W T.H. Replacement Bulb
Pir & Flood 500W
Class 2 Independently mounted control EMC directive
2004/180/EC
Zone 1
Zone 2
Zone 3
Zone 4
D -Tect
Detectors
Mains Supply
Mains Supply
DygiZone Master Controller Point 1
DygiZone Slave Controller Point 2 (up to 2 can be used)
“LV” Alarm Cable
Mains Cable
Chapter 13 Page 4
Intruder Catalogue
03/12
Intruder_Ch12_DetectorsTemp:Layout 1 20/03/2012 10:22 Page 2
Chapter 12 - Detectors - Temperature
This page is left intentionally blank.
Chapter 12 Page 2
Intruder Catalogue
03/12
Intruder_Ch14_LifeSafetyDevic:Layout 1 20/03/2012 10:25 Page 1
Chapter 14 - Life Safety Devices
Life Safety Devices
Fire and water are potential threats to the safety of a person. With this range of products you can add additional security to
every customer.
Features
•
•
•
•
•
•
•
Detects most carbon based types of fires
Provides very early warning for slow smouldering fires
Ideal for sleeping risks such as residential homes
High resistance to false alarms
Tolerant to various detector mounting positions
Negligible sensitivity to air speed
Compatible with most existing residential burglar alarm
systems
• Low profile, discreet and unobtrusive
• Environmentally friendly
• CE marked
SGU-601
The SGU-601 is based on the MU601 Carbon Monoxide
Fire Detector which is used for commercial fire detection
systems. The SGU-601 is powered from external 12Vd.c.
and provides a non-latching alarm signal to the panel when
Carbon Monoxide levels exceed the fire detection level.
The following design rules should be followed when
applying the SGU-601:
Technical Specification
Product Codes
CO Detection
Threshold:
Detector Material:
Dimensions:
Weight:
Colour:
Operating
Temperature:
Storage Temperature:
Relative Humidity:
03/12
• The SGU-601 is designed to be used on Residential
Intruder detection systems only
• Only one or two SGU-601 should be used on each
detection zone
• A separate fire signal must be used for central station
signalling
• A separate alarm sounder is recommended to indicate
fire condition
• Where a separate sounder is not available the internal
sounder should be used
616.023.001
440ppm
FR110 “Bayblend” Fire Resistant
Ø106 x 53mm
0.2kg detector and base approx
White
Range 0° to +50°C
-25°C to + 80°C
95% non-condensing
617.050.001
616.023.001.A
616.023.007
Intruder Catalogue
SGU-601 12V CO Fire Detector for use
with Residential Intruder Alarm Systems
SG600 Detector Base for SG601 12V CO
Fire Detector
SGU-601 12V CO Fire Detector for use
with Residential Intruder Alarm Systems
with ADT Branding
SGU601 12V CO Fire Detector complete
with SG600 Detector Base. For use with
Residential Intruder Alarm Systems. ADT
Branded
Chapter 14 Page 1
Intruder_Ch14_LifeSafetyDevic:Layout 1 20/03/2012 10:25 Page 2
Chapter 14 - Life Safety Devices
Features
• Automatic drift compensation
• Dust tolerant chamber provides optimum detection
performance and minimal nuisance alarm between
maintenance visits
• Multi-function, handheld remote programming and test
tool
• Programmable sensitivity via a handheld tool
• Digital addressing capability
• Advanced maintenance features are implemented via
handheld tool, reducing on site time
• Read and Write last maintenance date
• Read chamber contamination level
• Read thermal element value
• Alarm test
• Selectable Blink/No-Blink LED option via handheld tool
• Automatic alarm test via hand-held tool
• Photoelectric, multi-criteria photo-thermal, fixed and rate
of rise thermal detectors
• Backward compatibility with Series 100 bases enables
upgrade, extension and maintenance of existing
installations
• 8 to 30VDC operating range enables operation in both fire
and security systems
• -30 to +70oC operating temperature range
• Multi-functional Alarm - Normal bi-colour LED indicator
• EN54 (2000) part 7 Certified (Amendment 1)
System Sensor 12V Smoke Detector
The series 300 range of detectors has been produced using
the latest in manufacturing and design techniques, pushing
out the bounderies of existing conventional detector
technology. With its multitude of innovative features, the
Series 300 is a detector which “acts conventionally, thinks
intelligently”.
To maximise their flexibility several versions of the base are
available to ensure compatibility with the maximum number
of control panels:
Service and maintenance is also simplified because the
contamination level of the serving chamber can be read
maintenance dates can be written and an alarm test can be
instigated - all through use of the same handheld tool.
B312NL Non-latching relay base. This base is designed for
use in 12V 4 wire security systems which do not provide a
reset facility. The B312NL automatically resets the smoke
detector when a fire condition no longer exists, Because of
the self-rest feature, this base is ideal for the control of
electrical apparatus such as air conditioning systems in
systems using a 12V power supply instead of a control
panel. Current limiting in the alarm state is provided by the
circuit built into the base. The product is self resetting from
alarm and this is achieved by periodically removing the
supply voltage from the detector ad checking afterwards
that the detector is still in alarm. While the detector is still in
alarm the LED will be on, although it will flash when the
alarm check is performed.
Systems Sensor’s range of conventional relay bases can be
used to interface smoke detectors to 4 wire security panels
or to provide relay output suitable for the operation of door
closes etc. When used with 2 wire fire alarm panels. The
bases are compatible both with 4 wire security type
systems using a normally closed contact and 4 wire fire
alarm panels using a normally open contact.
B412RL latching relay base. This base does not
automatically reset the detector, allowing for easy
identification of the detector which caused an alarm. This
base can be used in 4 wire security systems with a reset
facility. it can also be used to provide a relay output from a
detector installed on a 24V 2 wire fire systems using a
series resistance greater than 470ohm.
Technical Specification
Product Codes
Series 300 is the paradigm shift in conventional fire detector
technology. This new range is the first to benefit from our
latest innovation-remote test and configuration capability
from the ground using a handheld test. Series 300 is
feature rich, including sensitivity selection, addressability,
and status indication using a bi-colour LED.
Dimensions:
Supply Voltage:
Power:
Chapter 14 Page 2
102Dia mm (Detector)
29H x 127 dia mm (Base)
15-32Vdc (Detector)
9.5V-15.0 Vdc(Base)
[email protected] Vdc (Detector)
[email protected] Vdc (Base)
2351-E
2351TEM
4351-E
5351E
B312NL
B312RL
Intruder Catalogue
SYS Low Pro Optical Smoke Detector
SYS Low Profile Multi-Criteria Smoke/Heat
Detector
SYS Fixed Temp (78°C) Heat Detector
SYS Rate of Rise Temp Detector (58°C)
SYS 12 Volt Non-Latching Relay Base
SYS 12 Volt Latching Base
03/12
Intruder_Ch14_LifeSafetyDevic:Layout 1 20/03/2012 10:25 Page 3
Chapter 14 - Life Safety Devices
Features
•
•
•
•
An economical extinguisher for use in car or home
Ideal where space is at a premium
Factory sealed unit requiring minimal maintenance
Supplied with steel spring clip for easy installation
Fire Extinguishing
0.6 Kg dry powder factory sealed stoved pressure type
complete with bracket.
Product Code
K-100D
0.6Kg Dry Extinguisher
Features
•
•
•
•
•
•
•
Single piece designs for long lasting service
No end caps to lose
Aesthetically pleasing design
Hinged lid for easy extraction
Moulded keyhole for added strength when hanging
Large labelling area for maximum impact
Kitemark to BSEN 1869:1997
Fire Blanket
Fire Blanket, 110 x 110 cm. In red plastic wall mountable
holder. Accredited to BSEN 1869. Made of Silicone coated
fibreglass.
Product Code
EB1212
03/12
Intruder Catalogue
Fire Blanket - 1.2m x 1.2m
Chapter 14 Page 3
Intruder_Ch14_LifeSafetyDevic:Layout 1 20/03/2012 10:25 Page 4
Chapter 14 - Life Safety Devices
Detector Test Equipment Point Detector Testing/Commissioning Equipment
Telescope Poles
Product Codes
517.001.230
SOLO100 Telescopic pole 1.26M to
4.5M long
517.001.226
SOLO101 Extension tube 1.13M long
for use with 517.001.230 Telescopic
extension pole
517.001.264
SOLO 610 Protective Carry/Storage
Bag for Solo Detector Test Kit
SOLO724 charger. (Connects directly
to SOLO100/101 poles).
517.001.242
SOLO720 Spare battery baton for use
with SOLO 450/460 tester
517.001.243
SOLO725 Spare mains/car battery
charger for SOLO720 battery baton
SOLO330 Test Gas Dispenser
Product Code
517.001.255
SOLO330 Aerosol dispenser for use
with all detector ranges. Connects
directly to SOLO100/101 poles
SOLO461 Heat Detector Tester
Product Codes
517.001.254
SOLO461 Cordless heat detector
tester kit including SOLO460 tester,
SOLO720 battery batons and
Smoke Detector Test Gas
Product Code
517.001.256
Suretest Solo aerosol tester can. For
use with SOLO 330 dispenser. Nonflammable, ozone and environment
friendly. Approx 200 tests per can
CO Detector Tester
Product Code
517.001.262
CO Detector Tester Solo C3-006 for
use with Solo 330 dispenser
Chapter 14 Page 4
Intruder Catalogue
03/12
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 1
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Intruder Alarm Control Panels
Tyco Safety Products support a wide range of control panels for use in Intruder Alarm applications. All systems are selected on the
basis of flexibility, reliability and functionality.
From a cost effective residential application up to a large complex commercial system, this range will include suitable control
panels. Products are selected from our key suppliers Aritech, Europlex.
Honeywell Galaxy Range
Features
• Dual path signalling via PSTN and GSM (only
available on Galaxy 2-44+)
• SMS text signalling to up to 3 mobile numbers
• Remote diagnostics
• Up to 44 zones
• Pr EN50131-1 Grade 2 compliant
• New: Door control and set/unset capability using MAX04
proximity card reader
• New: RF portal for superior bi-directional wireless
performance on 868 MHz.
• New: Dual path signalling over PSTN and/or IP networks
• Hybrid system which supports both hardwired and
wireless peripherals
Galaxy G2
Suited to all residential and small to medium size
commercial, PD6662:2004/prEN50131-1:2004 grade 2,
installations the Galaxy 2 series control panel range
provides feature rich, easy to use, security products with
great flexibility.
Compatible with the existing Galaxy peripheral range the
Galaxy 2 series utilises the familiar Galaxy user and
programming architecture.
Peripherals
The Galaxy 2 Series is supported by a comprehensive
peripheral set.
On the Galaxy bus:
Galaxy Mk7 LCD Keypad
2 x 16 alphanumeric character display
Galaxy Power RIO
2.75A EN50131-1 grade 3 compliant PSU with
integrated RIO
Galaxy alphanumeric LCD Keyprox
Equivalent to Galaxy Mk7 keypad with integrated
ASK prox reader
Allows the system to be set and unset by use of
proximity card
Can be used for DD243 compliant system
configuration
RIO
System expander module - 8 zones/4 outputs
03/12
RF Portal
Receiver for the Domonial V2 wireless peripheral
range
Additional RF Portals can be used to
increase wireless range
Provides full wireless diagnostic information
V2 wireless peripheral range
Aesthetically pleasing wireless transmitter devices
with excellent wireless performance
Intruder Catalogue
Chapter 15 Page 1
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 2
Chapter 15 - Intruder Alarm Control Panels - Galaxy
G2 Features
Zones
Outputs
RIO (8 zones/4 outputs)
Databuses
Integrated PSU
Alphanumeric LCD Keypads
Alphanumeric LCD KeyPro
RF Portal
User Codes (PIN and Card)
Groups
Part Set
Silent Night Set
Zone Types
O/P Types
Event Log
Multi-Users
Printer Module
PSTN Communicator/V.22 Modem
GSM Communicator/Modem
Serial Port
Galaxy
2-12
12
4+8 (via header)
1
Galaxy
2-20
12 to 20
4+8 to 16
2
RS485 Only
1A (0.6A @ Grade 2)
4
4
2
23
3+1 common group
2 Part Sets
Yes
18
23
387
4
Optional
On-Board
1 on-board
Galaxy
2 - 44
12 to 44
4+8 to 28
4
Product Codes
UK Panels
C012-36-C
C020-36-C
C043-36-C
C012-63-C
C020-63-C
C043-63-C
RoI
C012-84-C
C020-84-C
C043-84-C
C012-85-C
C020-85-C
C043-85-C
Chapter 15 Page 2
Intruder Catalogue
Galaxy G2-12 Zone control panel with
commercial defaults
Galaxy G2-20 Zone control panel with
commercial defaults
Galaxy G2-44 Zone Control Panel with
Commercial Defaults
Galaxy G2-12 Zone Control Panel with
Residential Defaults
Galaxy G2-20 Zone control Panel with
Residential Defaults
Galaxy G2-44 Zone Control Panel with
Residential Defaults
Galaxy G2-12 Zone control panel with
commercial defaults
Galaxy G2-20 Zone control panel with
commercial defaults
Galaxy G2-44 Zone Control Panel with
Commercial Defaults
Galaxy G2-12 Zone Control Panel with
Residential Defaults
Galaxy G2-20 Zone control Panel with
Residential Defaults
Galaxy G2-44 Zone Control Panel with
Residential Defaults
03/12
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 3
Chapter 15 - Intruder Alarm Control Panels - Galaxy
G2 System Architecture
12-way ribbon cable
External
Communicator
Program Header (for remote
servicing)
Trigger Header
RS485 BUS
Phone Line
Maximum cable length
form panel to last module
on line is 1Km
12 on- board zones
4 Outputs
Note: A maximum of 4 keypads
(including keyprox) can be
connected to the RS485 line
Mk7 LCD Keypad/Keyprox (4)
4 Outputs
MX04-NC
Rio (4) C072
8 Zones
OR
4 Outputs
Power Unit (4) P025 or
Power RIO (4) P026
8 Zones
Twisted pair screened cable Belden 87
equivalent. Daisy chain configuration only.
RF Portal (2)
03/12
Intruder Catalogue
Chapter 15 Page 3
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 4
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Specifications
Panel Specifications
2-20
Physical
Plastic Box-3 mm polycarb
(with mains transformer and PCB installed) Width: 300 mm
Height: 250 mm
Depth: 100 mm
Weight: 1.7 kg
Metal Box-1.2 mm steel
(with mains transformer and PCB installed) Width: 400 mm
Height: 255 mm
Depth: 115 mm
Weight: 4.2 kg
Electrical
Panel Current Consumption
120 mA (max)
PSU Type
A
230 V ac (+10% -15%)
Mains Input
Up to 7.2Ahr 12 V Sealed
Back-up Battery
Lead-Acid (plastic encl.)
Up to 12Ahr 12 V Sealed
Lead-Acid (metal encl.)
PSU Max total load
1.0 A (nominal temp. and mains supply)
Grade 2 Rating
600 mA
Max continuous ripple voltage
0.5 V at max. load
Individual 12 V outputs:
Bell+12V
Both Aux+combined
Trigger Header+12V
500 mA max
500 mA max
100 mA max
Switched Outputs:
Trigger Header Outputs
Bell Trigger 1003
Strobe Trigger 1004
Trig Output 1001
Can
Can
Can
Can
Speaker Output:
Speaker output 1002
8 to 32 ohms or 100 mA in switched DC mode
Fuses:
Mains
Battery (F1)
Aux (F2)
Bell (F3)
200 mA-20 mm anti-surge (IEC 127)
1 A, 20 mm anti-surge
500 mA, 20 mm anti-surge
500 mA, 20 mm anti-surge
sink
sink
sink
sink
30 mA each
500 mA max
500 mA max
300 mA each
Galaxy 2 Series Installation Manual
Peripheral Quiescent
Mk 7 Keyprox
RIO
Power RIO/Power Unit
RF Portal
6160 Keyprox
5800 RF Receiver
ECP Expander
GSM Module
Chapter 15 Page 4
Maximum Alarm
Current (mA)
90
40
100
55
40
60
25
10
Current (mA)
130
200
Intruder Catalogue
03/12
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 5
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Galaxy Dimension Series
Features
•
•
•
•
•
•
•
•
•
•
Galaxy Dimension Series
The new Galaxy Dimension series is the next generation of
intruder alarms from the established Galaxy range. Based
on the market leading Galaxy 3 series, it provides high
quality, reliable security solutions for commercial and
industrial applications.
Galaxy's latest version - Dimension - also now includes
enhanced access control features. With one integrated
system, operation is simpler for the end user and is easier
for the engineer to program, commission and maintain.
Technical Description
Description
Zones onboard (maximum)
Outputs (400mA) on-board
Trigger outputs on flying lead (10mA)
Integrated PSU
RS485 Databuses
Keypads (Keyprox)
Graphics Keypad Galaxy TouchCenter
Bus mounted prox readers (MAX)
DCMs with 2 x Wiegand interfaces
DCM controlled doors
Wireless RF Portal
Total Number of wireless sensors
Total Number of wireless key fobs
Users
7 Day Timer Schedules
Zone types
O/P types
Library
Event Log
Access Log
Multi-users
Autoset
Pre-Check
Timed Lockout
Links
Part Set
Silent Part Set
RS232
Integrated PSTN (V 22)
Printer Output
Remote Servicing
Ethernet module
Groups
Audio Verification channels
SMS text
ISDN
EN50131
03/12
GD-48
16 - (48)
8
6
2,5 A
1
8 (3)
1
4
4
8
4
32
50
100
19
52
81
Yes
1000
1000
Yes
Yes
Yes
Yes
64
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
8
8
Yes
Optional
Yes
GD-96
Up to 64 doors controlled
Up to 1000 users
Protecting up to 32 groups
Door access controlled by access templates and group
set status
Groups can be set by pressing the Menu Recall button
before card swipe, or by triple swipe
A system keypad can be linked to each reader for Menu
Recall function control
Up to 32 audio verification channels
Multi-language interface
Compatible with all wiegand keypads that use 8-bit
Burst mode
New graphical colour TouchCentre
Non PC Networked Access Control Solution
Galaxy Dimension combines the best intrusion features with
advanced access control functions in a single, integrated
system. Installing and programming a full security system
becomes easier, quicker and more efficient. With only one
system to install and maintain, one point of contact for
Technical Support and one training session for the complete
system, there are savings in both time and money. Offering
this Non PC based access control system for small
industrial & commercial premises provides a user friendly
system with upgrade facility to integrated & intruder &
access control at a later date.
16 - (96)
8
6
2,5 A
2
16(7)
2
16
16
32
8
80
100
250
35
52
81
Yes
1500
1000
Yes
Yes
Yes
Yes
128
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
16
32
Yes
Optional
Yes
GD-264
16 - (264)
8
6
2,5 A
2
16(7)
2
16
16
32
8
192
100
1000
67
52
81
Yes
1500
1000
Yes
Yes
Yes
Yes
256
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
32
32
Yes
Optional
Yes
GD-520
16 - (520)
8
6
2,5 A
4
32(24)
4
32
32
64
8
192
100
1000
67
52
81
Yes
1500
1000
Yes
Yes
Yes
Yes
256
Yes
Yes
Built-in
Built-in
Via RS232
Yes
Optional
32
32
Yes
Optional
Yes
Chapter 15 Page 5
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 6
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Galaxy Dimension Systems Architecture
PSTN Line
RS232 (serial Port)
6
A229
(Trigger cable to connect 6
additional outputs)
Bus cables:
CAT5 cable or twisted pair screened
cable, Belden 8723 equivalent,1km maximum
GD-520
GD-96/264
RS485 BUS
Line 1
Line 3
16
RS485 BUS
Line 1
Line 4
GD-48
Line 2
8
Line 2,3 4
Programming / Maintenance
A227
Same Configuration for buses
2,3,4
SPI key (copies configuration) Remote servicing suite
Galaxy Dimension
TouchCentre
Galaxy Dimension
TouchCentre
User-friendly control
Keypad or Keyprox
Keypad or Keyprox
Black tag: YX0-0004
Card: YX0-0002
(Keyprox and MAX)
(Keyprox and MAX)
Grey tag: YX0-0020
(Keyprox compatible only)
Max Badge reader
MX04-NC
Max Badge reader
MX04-NC
CO80
CO80
DCM
or DCM with PSU
DCM
or DCM with PSU
CO81
CO81
Door
lock
Weigand
Reader
Access control
Exit
Button
Exit
Button
Weigand Door
Reader
Lock
PO25
Intelligent PSU 2.75A, rated at
1.2A for Grade 3 compliance
4
Intelligent PSU 2.75A, rated
at 1.2A for Grade 3
compliance
8
8
Intelligent power supply
4
Power RIO combines Power
Supply and RIO in one cabinet
CO72
RIO Expander module, 8
inputs, 4 outputs
Power RIO combines Power
Supply and RIO in one cabinet
PO26
8
4
Wired Zone expanders
8
4
CO76
Wireless receiver - RF
Portal
Wireless devices
Wireless receiver
RF Portal
EO80
Ethernet module (x1)
RIO Expander
module, 8 inputs,
4 outputs
IP network
A211
ISDN module (x1)
ISDN
Chapter 15 Page 6
Intruder Catalogue
03/12
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 7
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Galaxy Dimension Systems Access Layout
RS485 bus
12VDC Power in
Touch Centre
Galaxy Dimension Board
(x 2)
Mifare 34 bit
OR 26bit
ioProx
(x 2)
Exit Button
(x 2)
DCM Board
(x 2)
Use the DCM for fully programmable
access control and maximum choice of
card/reader technology
Breakglass
Mag Lock
Door Contact
Product Codes
C048-C-C1
C096-C-C1
C264-C-C1
A321-C-C1
A322-C-C1
A323-C-C1
CP041-36
CP042-36
C080
C081
CP038-36-H
A229
A227
A228
A221
A234
03/12
Intruder Catalogue
Galaxy Dimension 48 zone panel with UK
and ROI defaults for both RESI and
COMMERCIAL
Galaxy Dimension 96 zone panel with UK
and ROI defaults for both RESI and
COMMERCIAL
Galaxy Dimension 264 zone panel with UK
and ROI defaults for both RESI and
COMMERCIAL
Galaxy Dimension 48 UK PCB
Galaxy Dimension 96 UK PCB
Galaxy Dimension 264 UK PCB
Galaxy Touchcentre with ADT Logo
Galaxy Touchcentre Prox with ADT Logo
Galaxy Door Control Module
Galaxy Power Door Control Module
Galaxy Keyprox ADT (HID)
Galaxy Dimension Trigger Lead
Galaxy Dimension SPI Programming Key
(Blank)
Honeywell G2 Trigger Lead
Honeywell G2 Programming Flash Lead
Honeywell Dimension RS232 cable kit
Chapter 15 Page 7
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 8
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Interfaces and RF Ancillaries - G2 and Dimension Panels
C079-2
Product Code
C079-2
RF Portal V2
alpha protocol
universal
Slimline Door Contact
Product Codes
DO800M
Slimline white
door contact
DO800M2
Slimline brown
door contact
Passive Infrared Sensor
Product Code
IR8M
IRPI8M
PIR10m
RF PIR 10m Pet
Tolerant version
Dualtec Motion Sensor
Product Codes
DTPI8M
RF Dualtec
Motion Sensor
with Pet Tolerant
DT8M
RF Dualtec
Motion
Sensor - High
Security
Smoke Sensor
Product Code
DF8M
Honeywell Alpha &
V2 protocal RF
smoke sensor
RF PAB
Product Code
TCBPA8M-1
Black PA keyfob
RF Set/Unset FOB
Product Codes
TCC8M
HON round
set/unset RF Fob
TY-CR2032-BL5
Replacement
battery (Pack of
5)
TCCBASE
Belt Clip Bracket
Features
• Feedback on all actions
• System status on request
• Warning in case of intruder alarm
on disarm
• Warning for low battery
• Black standard references
• Set of 3 colour rings
•Belt Clip Bracket available
Chapter 15 Page 8
Intruder Catalogue
03/12
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 9
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Door Contact with Supervised Input
Product Code
DODT8M
Galaxy RF door
contact with
supervised input
Alpha protocol
Flood and Temperature Sensor
Product Code
DET8M
RF Flood & Temperature
Sensor
Remote Refrigerator Probe
Product Code
T280R
Remote Refrigerator
Probe to be used
with DET8M and
temperature sensor
Acoustic Break Glass Sensor
Product Code
FG8M
RF Acoustic Glass
Break Sensor
Shock Sensors with Contact
Product Codes
SHKC8M RF Viper (Piezo
Shock Sensor) with
Contact - White
SHKC8M2 RF Viper (Piezo
Shock Sensor)with
Contact - Brown
Shock Sensor
Product Code
SHK8M
03/12
Intruder Catalogue
Shock Sensor
Chapter 15 Page 9
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 10
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Interfaces and Ancillaries
Galaxy Keypad
Galaxy Controllers will communicate
with a number of keypads, ranging
from 3 (Galaxy 8+/16), to 16 (Galaxy
18/60/128) and up to 32 keypads on
the Galaxy 500/504/512.
All the user and engineer controls are
presented on the keypad for simple
operation. An uncomplicated, menu
driven procedure leads any user
through the facilities available at that
particular password level.
Setting and unsetting the system is
carried out by entering a valid PIN
and pressing the A key. The keypad
is supplied in two variants, either
commercial or residential.
The residential keypad has “Hot
Keys” which allow the user to
generate a Police, Fire or Assistance
Call through to the Alarm Receiving
Centre.
Residential keypads must be used on
panels with residential defaults.
Technical Specification
Dimensions:
100H x 154W x
35Dmm
Product Code
608.010.009
Galaxy Mk 7
Remote keypad for Commercial use
CP027-36
Galaxy Keyprox
The Galaxy Keyprox is a standard
MK7 keypad and a proximity card
reader, combined into one housing.
This allows dual function
setting/unsetting ability from the one
unit without the need for a separate
card reader. It is primarily intended for
use in situations where a PIN and/or
card are needed to set and unset the
Intruder Alarm System. It is not
intended to be used for door control
as it does not contain a door strike
relay. However, limited door functions
can be programmed using
programming links in the Galaxy
Control Panels.
Product Codes
608.010.323
Galaxy Keyprox Intruder keypad with
Integral proximity reader Module (for
use on new installations to meet
DD243 July 2002 compliance).
Please note the fobs for this unit are
stockcode A38402
1346LSSM-H10302.1
HID: 1346LSSM Format: H10302
ProxKey II Keyfob programmed for
HIDs tracked 37bit Wiegand format.
Supplied with HID logo on the front,
back is standard finish. Numbering is
sequential internal & external. These
can be ordered individually
CP038-36-H
Galaxy Keyprox Intruder keypad with
Integral proximity reader Module with
HID Prox Reader (for use on new
installations to meet DD243 July 2002
compliance).
Galaxy MAX04
Product Code
MX04-NC
Galaxy MAX04 Standard
version with Normally
closed relay
MAX04 is a sophisticated door control
module which uses proximity card
reader technology to combine
performance with flexibility and
economy. The MAX04 can be
integrated with the majority of the
Galaxy range of control systems or
operate as a stand alone module.
Galaxy Keyprox + MAX04 Keyfob
Product Code
A38402 Keyfob
Galaxy Keyprox + MAX04 Keyfob
Galaxy MAX04 Proxcard
Product Code
A38403 Galaxy MAX04 Proxcard
Galaxy MAX04 Proxcard
Galaxy Keyprox Keyfob
Product Code
YX0-0020 Galaxy Keyfob
Galaxy Keyprox Keyfob for use on the
Mark 7 Keyprox keypad only. Not to
be used on the MAX04 reader (use
A38402 instead).
Chapter 15 Page 10
Intruder Catalogue
03/12
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 11
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Interfaces and Ancillaries
Galaxy G2 Replacement PCB
Galaxy G2 Replacement PCB
Product Codes
A244-63 Galaxy G2012 PCB ADT
RESIDENTIAL
A245-63
A246-63
A244-36
Galaxy G2-20 PCB ADT
RESIDENTIAL
Galaxy G2-44 PCB ADT
RESIDENTIAL
Galaxy G2-12 PCB ADT
COMMERCIAL
A245-36
A246-36
Galaxy G2-20 PCB ADT
COMMERCIAL
Galaxy G2 44 PCB ADT
COMMERCIAL
Galaxy Dimension Replacement PCB’s
Product Codes
A321-C-C1
Galaxy Dimension 48
UK PCB
A322-C-C1
Galaxy Dimension 96
UK PCB
A323-C-C1
Galaxy Dimension 264
UK PCB
Galaxy Dimension Replacement
PCB’s
Plug-On Expander for Galaxy Dimensions
Product Code
E485-2
Plug-On Expander for
Galaxy Dimension
The Plug-On Expander for Galaxy
Dimension expands from 264 to 520
zones.
Galaxy Telecoms Module E062
Product Code
7633
Galaxy Telecomms
Module E062
Galaxy Telecomms Module E062
Galaxy G2 External Signalling Interface
Product Code
A232
Galaxy G2 External
Signalling Interface
Galaxy G2 External Signalling
Interface for Redcare or DualCom
Plus
Ethernet Module
Ethernet Module PCB only.
Compatible with Galaxy classic V400
and later, and G3 Panels.
Product Code
E080-2
Ethernet Module PCB
Galaxy Remote Input Output Unit
(RIO) in Plastic Box. 8 Zone Input, 4
Darlington Driver Output, Data Bus
Interface (C072-36).
Product Code
608.010.055
Galaxy RIO
Galaxy RIO
Honeywell Galaxy Door Guard
Door Guard Interface
A module which is used to provide
protection to doors requiring
immediate local alarm warning.
• The Door Guard Interface can be
configured for both stand-alone
use (connected to a power supply
only) or as an integrated unit with
the Galaxy security system
providing details of door status at
the control panel
03/12
• Door access requires a key, which
temporarily suspends the door
monitoring
• Unauthorised access to a
protected area results in a local,
audible warning as well as an
indication at the Galaxy panel
Intruder Catalogue
Product Codes
6631
Galaxy Door Guard
(CO75)
C075W-C Honeywell Door Guard
(common key)
Chapter 15 Page 11
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 12
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Printers & Interfaces
The LQ 300 printer is designed as a low cost
business printer ideally suited for use with
the Galaxy range of Control Panels (use
6521). The printer interface allows either real
time printing of all events or print, on
request, of items held in the log.
Product Codes
6521
Galaxy printer interface. Converts RS485
data base to RS232 standard printer output
format. 25pin D-Connector.
The printer interface will operate in
conjunction with any standard serial printer.
557.180.239
LQ 300+II Epson Dot matrix alarm printer 24 pin 80 character
RS232 Communication Module
The RS232 Communication module has
three distinct operating modes. It can
operate as either a printer interface, a
memory buffer or a direct connection
interface to a PC package. As a printer
interface, the unit converts the system RS485
to standard printer format RS232 for
connection to any serial printer. As a
memory buffer, the unit can be used to
download the programming parameters of a
panel for temporary storage.
The information can later be uploaded either
to a PC package or another panel. This
functionality is particularly useful when
upgrading systems.
In direct connect mode the unit allows the
control panel to be connected directly to a
PC running Galaxy Gold and/or alarm
monitoring software. This enables local
monitoring and control of the control panels
on a PC that may be located in the Guard
house for instance.
Product Codes
6620
Galaxy RS232 communication module in
metal housing. Used for direct connection to
PC when using download/upload software or
alarm monitoring software. Can also be
used as a memory buffer when upgrading
control panels V2.01.
Ancillaries
The Galaxy 4 way relay interface is used with
RIO’s to connect the 12V Darlington Driver
outputs to clean relay signals. This is
particularly useful to trigger response events
on a CCTV System or other monitoring type
package. The Galaxy Doorguard unit
provides an d”Exitguard” facility when used
with Galaxy 60/500 or 512. “Exitguard”
enables a fire exit door to be monitored
locally, even when the alarm is unset.
Anyone opening the fire exit door will cause
the buzzer to sound. Operation of the on
bard keyswitch isolates the door and allows
authorised access/egress without an alarm
being raised.
Product Codes
6628
Galaxy 4 way relay interface to convert
Darlington driver outputs of field device
interface to clean relay outputs.
A221
Galaxy G2 programming lead for use in
upgrading software versions with a laptop,
file needed from resolve
A234
Galaxy G3 & Domonial RS232 cable Kit, for
use with G3 and Dimension Panels
Chapter 15 Page 12
Intruder Catalogue
03/12
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 13
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Panel Specifications
Mechanical (all variants)
Enclosure (with PCB and transformer) Width: 440 mm, Height: 352 mm, Depth: 90 mm, Weight: 6.4 kg
Physical space for batteries
2 x 17Ah Max (not suitable for 12Ah batteries)
PCB only
Width: 265 mm, Height: 120 mm, Depth: 47 mm, Weight: 0.3 kg
Operating temperature:
-10 deg.C to + 55 deg.C
Electrical
Mains input:
230V ac (+10%/-15%) @ 50 Hz
Power supply:
Type A
GD-48
Total capacity 1.5 A (0.75 A dedicated to battery)
Operating temperature:
-10 deg.C to +40 deg.C
Power supply:
Type A
GD-96/264/520
Total capacity 3 A (1.5 A dedicated to battery)
Operating temperature:
-10 deg.C to +40 deg.C
Auxiliary +
12V outputs: 12V nominal
GD-48
0.5 A in total
50.0 mV maximum ripple
Auxiliary +
12V outputs: 12V nominal
GD-96/264/520
1.0A in total
50.0 mV maximum ripple
Fuses
AUX1
1.0A - 20 mm anti-surge
AUX2
1.0A - 20 mm anti-surge
BELL
1.0A - 20 mm anti-surge
BATT GD-48
1.0A - 20 mm anti-surge
BATT GD-96/264/520
1.6A - 20 mm anti-surge
PSTN
V.22 Modem 1200 Baud
RS232
300 - 56k programmable
RS485
9600 Baud, Full Duplex, Asynchronous
Module Specifications
Modules
Galaxy Keypad (MarkVII)
Size:
Weight
190 g
149 x 91 x 31 mm (L x B x H)
Order Code
CP027
Galaxy Keyprox (Mark VII)
Size
Keypads Material
Keypad Colour
190 g
149 x 91 x 31mm (L x B x H)
CP028
Galaxy TouchCenter
Size
500 g
182 x 128 x 34 mm (L x B x H)
CP040
MAX3 (Boxed)
Size
267 g
185 x 120 x 48 mm (L x B x H)
MX03
Galaxy RIO (Boxed)
Size:
300 g
150 x 162 x 39 mm (L x B x H)
C072
Galaxy RF RIO (Boxed)
Size
270 g
150 x 162 x 39 mm (L x B x H)
C076
RS232 Module (Boxed)
Size:
823 g
180 x 155 x 35 mm (L x B x H)
E054
Door Control module (Boxed) No PSU
Size
270g
150 x 162 x 39 mm (L x B x H)
C080
Door Control module (Boxed) with PSU
Size
300g
150 x 162 x 39 mm (L x B x H)
C081
Line Expander
Size:
820g
180 x 155 x 35 mm (L x B x H)
A226
Doorguard
Size:
995g C075
150 x 185 x 40 mm (L x B x H)
Printer Interface (6-Way DIN Plug)
Printer Interface (25-Way D Plug)
Box Size:
Cable Size:
120 g
A134
130 g
A161
75 x 52 x 28 mm (L x B x H)
2m for 4-Way IDC, and 0.3m for 6-Way/25-Way plug.
03/12
PC + ABS
Neutral
Intruder Catalogue
Chapter 15 Page 13
Intruder_Ch15_PanelsGalaxy:Layout 1 20/03/2012 10:28 Page 14
Chapter 15 - Intruder Alarm Control Panels - Galaxy
Galaxy PC Package
Features
•
•
•
•
•
•
•
•
Galaxy User Management Suite
The Galaxy User Management Suite software has been
developed specifically for in-house Security Managers.
This software provides a user-friendly interface to key
functions of the Galaxy security system allowing essential
changes and amendments resulting from personnel
changes or opening hours to be made, ensuring smooth
and continuous day-to-day operation.
The software provides access to:
•
•
•
•
•
•
Programmable user functions
System and door access event log copying
Displaying and printing of selected event log categories
Off-line data programming
Password protected access to Galaxy panels
Password protected access to User Management Suite
Single local site servicing
Multiple remote site servicing
For remote Galaxy sites allowing communication with
multiple control panels:
• PSTN telephone line (using the Galaxy Telecom Module)
• ISDN line (using the Galaxy ISDN Module)*
• 10BaseT Ethernet (TCP/IP) local and wide area networks
(using the Galaxy Ethernet Module)*
For local Galaxy sites:
User code management
Event log copying
Time and date change
Virtual keypad for real-time control*
Holiday period changes
Summer time date change
• A dedicated connection to a single Galaxy control panel
via the Galaxy RS232 Module
The Galaxy User Management Suite menu options provide
the operator with a comprehensive range of features that
allow site data be copied to and stored on the controlling
PC or modified overwritten to control panels.
User Management Suite can connect to Galaxy security
systems via the following communications media:
Technical Specification
PC Requirements
Operating system
Processor
Memory
Hard Disk space
Comm Ports
Specification
Windows 98SE, 2000, ME, XP, NT4 with SP3
P3 600Mhz minimum
128MB minimum
500MB minimum. More may be required depending on size of database
1 or 2
* Some features are dependent on the model of Galaxy control panel used. The Galaxy 2 series system can’t be used with event monitoring software.
Product Codes
R058-CD-DG
YY0-0010
Chapter 15 Page 14
Intruder Catalogue
End User system management software
UMS
Extra operator Dongle for UMS
03/12
Intruder_Ch16_PanelsDomonial:Layout 1 20/03/2012 10:29 Page 1
Chapter 16 - Intruder Alarm Control Panels - Domonial
Honeywell Domonial Panel
Features
•
•
•
•
•
•
•
•
•
•
Compact Control Panel
Innovative Peripherals
Easy installation
Rich Maintenance Tools
Superior Flexibility in daily use
Programmable output,
XM10 transmitter,
Remote audio devices and external tamper
Built-in sounder for intruder and fire alarm
Built-in PSTN communicator and optional plug-on GSM
module for connection to a monitoring centre or
nominated number: protocols Secom3, Contact Id, Cesa,
Surtec
• Built-in speaker/microphone: listen-in facility and talk
initiated by operator or user.
• Full set, part set and annex set functions for protection of
the entire site or separate areas
• Leading edge radio transmission technology
Domonial Wireless Security System
The high performance wireless consumer alarm system.
Domonial is a compact, wireless security system for
residential installations. Its built-in communicator brings
remote maintenance and diagnostics into general use for
routine inspections and alarm activations.The optional GSM
module can be used as a back up for the PSTN or as the
main network connection. A great choice of innovative
controlling equipment helps provide a system best-fitted to
every user's lifestyle.
Peripherals
The Domonial security system is complimented by a
comprehensive range of wireless peripherals and additional
wired extensions.
Maintenance tools & Alarm Receiver
The Domonial alarm system is programmed and maintained
using software tools developed for standard platforms:
Local and remote programming and maintenance on PC
• Windows 2000, XP support, serial connection to the panel
using specific cable, remote connection using secured
modem Domodem
•User-friendly user interface with online installation guide
and saving and reporting facilities
•Reference: DOMOPC
Local programming tool for PDA
•Palm OS support, serial or USB connection to the panel
using specific cable
•Interactive screens with a rich set of programmable
features
•Reference DOMOPDA
•PDA device can be supplied (PK-U version)
IST Technical server, PE Alarm receiver, WAP portal
•ISDN connection with dynamic channel allocation
•Audio and image processing for alarm verification
•Network services for automated installations maintenance
•Wap portal application
Domonial Wireless Security System
Slimline Door Contact
Product Codes
DO800M Slimline
white door contact
DO800M2 Slimline brown door
contact
Slimline door contact
Smoke Sensor
Smoke Sensor
Features
• Wireless smoke sensor with 100m2
• Dedicated maintenance fault
Product Code
DF8M
Honeywell Alpha & V2
protocal RF smoke sensor
information for chamber cleaning
03/12
Intruder Catalogue
Chapter 16 Page 1
Intruder_Ch16_PanelsDomonial:Layout 1 20/03/2012 10:29 Page 2
Chapter 16 - Intruder Alarm Control Panels - Domonial
Passive Infrared Sensor
Honeywell RF PIR
Features
• Discrete wireless PIR sensor with
10m range
• Compliant to latest European
2.7GHz EMC requirement
(mandatory for CE compliancy)
• Compliant with EN50131 rev. 2008
• Corner mount bracket (note: wa
mount bracket was already
included)
• Protected PCB for PI version.
Product Codes
IRPI8M
PIR (Pet Immune)
IR8M
Passive Inrared
Sensor
Features
• Discrete wireless Dualtec sensor
with15x18m range 24.200 GHz
(keyboard)
Product Codes
DTPI8M
RF Dualtec Motion
Sensor with pet
immune
DT8M
RF Dualtec Motion
Sensor - High Security
Dualtec Motion Sensor
Honeywell RF Dualtec
Domonial Internal Sounder
Product Code
SI800M
Domonial
Internal Sounder
Domonial Internal Sounder
Keypad and Keyfob
Keypad and Keyfob
Features
• Keypad with LCD display, TAG prox
reader and keypad for PIN
entry
• Full set/part set/annex set users
TAG and/or PIN setup
• Event log, system diagnostics,
•
receivers remote control
Can be used as programming tool
for the installer
Product Codes
TAGEU-ADT-G
TCU3UK-ADT-0
ADT proximity
Tag
Domonial White
TCU
RF PAB
Product Code
TCBPA8M-1
Black PA keyfob
RF Set/Unset FOB
Product Codes
TCC8M
HON round
set/unset RF Fob
TY-CR2032-BL5
Replacement
battery (Pack of
5)
TCCBASE
Belt Clip Bracket
Features
• Feedback on all actions
• System status on request
• Warning in case of intruder alarm
on disarm
• Warning for low battery
• Black standard references
• Set of 3 colour rings
•Belt Clip Bracket available
Chapter 16 Page 2
Intruder Catalogue
03/12
Intruder_Ch16_PanelsDomonial:Layout 1 20/03/2012 10:29 Page 3
Chapter 16 - Intruder Alarm Control Panels - Domonial
Shock Sensor
Product Codes
SHK8M
RF Viper (Piezo Shock
Sensor) - White
SHK8M2 RF Viper (Piezo Shock
Sensor) - Brown
Shock Sensor
Door Contact with Universal Input
Product Code
DODT8M
Galaxy RF door
contact with
supervised input
Alpha protocol
Flood and Temperature Sensor
Product Code
DET8M
RF Flood & Temperature
Sensor
Remote Refrigerator Probe
Product Code
T280R
Remote Refrigerator
Probe to be used
with DET8M and
temperature sensor
Acoustic Break Glass Sensor
Product Code
FG8M
RF Acoustic Glass
Break Sensor
Shock Sensors with Contact
Product Codes
SHKC8M RF Viper (Piezo
Shock Sensor) with
Contact - White
SHKC8M2 RF Viper (Piezo
Shock Sensor)with
Contact - Brown
RF External Siren
Product Code
SEF8M
03/12
Intruder Catalogue
HON Domonial RF
External Siren
Dual Protocol
Chapter 16 Page 3
Intruder_Ch16_PanelsDomonial:Layout 1 20/03/2012 10:29 Page 4
Chapter 16 - Intruder Alarm Control Panels - Domonial
Technical Specification
Feature
Zones / sensors
Keypads
Keyfobs
Wireless sirens indoor/outdoor
Receivers : Radio and X10 plugs,
IRVideo sensors
Alert functions
Users
Full set, Part set, Annex set
Built-in sounder
Built-in audio verification
Event log
Narrow band FM radio frequency
Wired output
X10 extension
Wired audio modules extension
Built-in PSTN communicator
Optional GSM communicator
System integrity and diagnostics
Specification
30
4
10
4
12
Details
The Domonial panel can register up to 32 peripherals in different
sensors, keypads, sounders and receivers configuration.
3
Up to 10
The master user sets up other users
3 protection areas
90 dBA
7 levels and progressive mode
Speaker/microphone
1000
10 sub-channels in the 868-870 MHz band with anti-jamming technology
1
Programmable
1
Connector to XM10 transmitter
Up to 3 TP modules
1
1
Tamper protection, Adaptive radio jamming detection,
Monitoring of peripheral radio transmission, power supply and PSTN/GSM
Product Codes
660.002.029
DOM-BAT-CRI
TCC8M
TCBPA8M-1
DF8M
IR8M
IRPI8M
DO800M
DO800M2
DODT800GY-B
SI800M
TCU-BASE-0
TAGEU-ADT-G
TCU3UK-ADT-0
CMI8UK-ADT-7
DET8M
DT8M
DTPI8M
T280R
FG8M
SHK8M
SHK8M2
SHKC8M
SHKC8M2
SEF8M
Chapter 16 Page 4
Intruder Catalogue
Replacement Battery, Power Line
Lithium Manganese Dioxide 3V Battery
(CR123A)
Domonial panel Battery
HON round set/unset RF Fob
4 Button keyfob (encrypted black)
Honeywell Alpha & V2 protocal RF smoke
sensor
Passive Infrared sensor
PIR (Pet Immune)
Door Contact (slimline) white
Door Contact (slimline)brown
Door Contact with Universal input
Domonial internal Sounder
Honeywell Domonial Spare White TCU
holster
ADT Proximity Tag (Grey)
Domonial White TCU
ADT Domonial compact wireless control
panel with built-in digital communicator
and 2-way audio verification, 32 detection
zones and 3 partitions, order battery
BA04V35 seperately RF Flood & Temperature Sensor
RF Dualtec Motion Sensor - High Security
RF Dualtec Motion Sensor with pet
Immune
Remote Refrigerator Probe
RF Acoustic Glass Break Sensor
RF Viper (Piezo Shock Sensor) - White
RF Viper (Piezo Shock Sensor) - Brown
RF Viper (Piezo Shock Sensor) with
Contact - White
RF Viper (Piezo Shock Sensor with
Contact - Brown
HON Domonial RF External Siren Dual
Protocol
03/12
Intruder_Ch17_Panels Le Sucre:Layout 1 24/01/2012 10:36 Page 1
Chapter 17 - Intruder Alarm Control Panels - Le Sucre
Honeywell Le Sucre PanelLe Sucre
Features
•
•
•
•
•
•
•
•
•
•
•
•
Recurring Revenue for ADT.
Proven reliable wireless technology, reduces call outs.
Clean, quick and unobtrusive installation.
The sucre is totally unobtrusive
Configures itself automatically
Compact
Up to 50 radio peripherals
Data transmission via GPRS
Battery Backup
High Quality Radio:
Common RF peripherals – Domonial, G2, Dimension
Remote flash upgrade of Le Sucre software
Note The sucre is fully based on the Domonial technology
Le Sucre Wireless Security System
Le Sucre is a non regulated wireless residential alarm
system, which is programmed using a PC’s browser and
Honeywell software, it communicates to the ARC via the
GSM network only (no PSTN).
Le Sucre uses Honeywell Alpha Peripherals only
(bi-directional protocol) It has a High performance RF
range: up to 2000m in open field and a low current draw,
which permits a long battery life.
The Le Sucre is not a Domonial or Galaxy G2 replacement,
therefore it can not provide ADT customer’s with a police
response.
The Residential market consists of regulated and non
regulated intruder alarm systems. In the past ADT has
concentrated on the regulated sector, due to non regulated
systems having no recurring revenue. However the non
regulated market is huge and therefore so is the potential
for ADT to grow their business, by offering an affordable
Keyholder only monitored alarm system.
Le Sucre range can handle maximum of 3 keypads per
system – there is one within the packages plus 2 additional
ones.
Use the wireless devices as per Domonial and Galaxy G2
RF product range. external Domonial sirens is not
compatible.
As this is unregulated product range, the following applies:
• The system is ungraded
• NSI certificate will not be issued
• No PD6662 compliance as unregulated system
• System test calls every 30 days
If the customer requires their home security system for
insurance purposes, the customer will need to confirm with
the insurer that this ungraded system is sufficient. Should
this not be the case, ADT Connect systems would provide a
regulated, NSI certified system alternative.
Le Sucre System
Le Sucre Keypad/Arming Station
Product Code
Le Sucre Keypad/Arming
Station
Control Pad
Product Code
Le Sucre Control Pad
12/11
Intruder Catalogue
Chapter 17 Page 1
Intruder_Ch17_Panels Le Sucre:Layout 1 24/01/2012 10:36 Page 2
Chapter 17 - Intruder Alarm Control Panels - Le Sucre
Slimline Door Contact
Product Codes
Slimline door contact
DO800M
White Ultrasmall wireless door contact
DO800M2
Brown
Ultra-small wireless door contact
Smoke Sensor
Smoke Sensor
Features
• Wireless smoke sensor with 100m2
• Dedicated maintenance fault
Product Code
DF8M
Honeywell Alpha & V2
protocal RF smoke sensor
information for chamber cleaning
Passive Infrared Sensor
Honeywell RF PIR
Features
• Discrete wireless PIR sensor with
10m range
• Compliant to latest European
2.7GHz EMC requirement
(mandatory for CE compliancy)
• Compliant with EN50131 rev. 2008
• Corner mount bracket (note: wa
mount bracket was already
included)
• Protected PCB for PI version.
Product Codes
IRPI8M
PIR (Pet Immune)
IR8M
Passive Inrared
Sensor
Features
• Discrete wireless Dualtec sensor
with15x18m range 24.200 GHz
(keyboard)
Product Codes
DTPI8M
RF Dualtec Motion
Sensor with pet
immune
DT8M
RF Dualtec Motion
Sensor - High Security
Dualtec Motion Sensor
Honeywell RF Dualtec
Domonial Internal Sounder
Product Code
SI800M
Domonial
Internal Sounder
Domonial Internal Sounder
RF Set/Unset FOB
Product Codes
TCC8M
HON round
set/unset RF Fob
TY-CR2032-BL5
Replacement
battery (Pack of
5)
TCCBASE
Belt Clip Bracket
Features
• Feedback on all actions
• System status on request
• Warning in case of intruder alarm
on disarm
• Warning for low battery
• Black standard references
• Set of 3 colour rings
•Belt Clip Bracket available
Chapter 17 Page 2
Intruder Catalogue
12/11
Intruder_Ch17_Panels Le Sucre:Layout 1 24/01/2012 10:36 Page 3
Chapter 17 - Intruder Alarm Control Panels - Le Sucre
Flood and Temperature Sensor
Product Code
DET8M
RF Flood & Temperature
Sensor
Remote Refrigerator Probe
Product Code
T280R
Remote Refrigerator
Probe to be used
with DET8M and
temperature sensor
Shock Sensor
Product Codes
SHK8M
RF Viper (Piezo Shock
Sensor) - White
SHK8M2 RF Viper (Piezo Shock
Sensor) - Brown
Shock Sensor
Door Contact with Universal Input
Product Code
DODT8M
Galaxy RF door
contact with
supervised input
Alpha protocol
Acoustic Break Glass Sensor
Product Code
FG8M
RF Acoustic Glass
Break Sensor
Shock Sensors with Contact
Product Codes
SHKC8M RF Viper (Piezo
Shock Sensor) with
Contact - White
SHKC8M2 RF Viper (Piezo
Shock Sensor)with
Contact - Brown
12/11
Intruder Catalogue
Chapter 17 Page 3
Intruder_Ch17_Panels Le Sucre:Layout 1 24/01/2012 10:36 Page 4
Chapter 17 - Intruder Alarm Control Panels - Le Sucre
This page left intentionally blank
Chapter 17 Page 4
Intruder Catalogue
12/11
Intruder_Ch18_PerimProctect:Layout 1 20/03/2012 10:34 Page 1
Chapter 18 - Perimeter Protection
Perimeter Protection
The Geoquip Fence and Warehouse Systems comprise of two main parts, the sensor cable that detects any disturbance
or vibration and the analyser to intelligently read and interpret the type of disturbance caused.
The characteristics of the sensor cable enable it to detect vibrations occurring at any point along its entire length without
reduction in sensitivity.
GeoQuip Perimeter Protection
Features
• Can be fitted to new or existing chain link, weld mesh or
palisade fences
• 24 hr detection before intruder gains entrance to site
• Highest intruder detection level with lowest false alarm
rate
• Can be integrated with CCTV and access control systems
Fence Protection
Perimeter fencing is an effective initial deterrent to intruders,
with metal fences being the most common form of physical
barrier. However, the determined intruder can breach any
type of fence structure, often by cutting through or climbing
over.
Many electronic security systems focus on detecting
intruders after entry to property. This often alerts police or
security too late to be able to prevent an intruder from
achieving his objective. Intruders make the most of the
time delay between entering the property and response by
security staff or police support following subsequent alarm
activation.
A well-designed perimeter fence will delay an invader,
providing an early opportunity for electronic detection.
Geoquip’s Defensor system is designed to pick up
vibrations as soon as any contact is made with the fence.
A security system which incorporates Defensor will alarm as
soon as an attack starts. During the time taken to breach
the fence, the area of attack can be located, security staff
mobilised and CCTV, lights and sirens activated. This
means that the control of the situation stays with the
security service and the attack can often be prevented.
A further advantage of early detection is the potential for
saving the fence from repairs, which are costly, represent a
security risk while awaiting repair, and weaken the defenses
in further attacks.
By detecting the first contact made by an intruder, Defensor
is a ‘primary’ detection system. Overall security can be
enhanced by secondary detection systems, such as Infra
Red and Microwave beams, which can track intruders
inside the perimeter.
NOTE: On larger, more specialised projects, please contact Geoquip for prices on non-catalogue parts such as FAC + HS parts call Bernie Alphonso on 07866 494 198 - UK South or Neil Peart - 07836 211 480 - UK North
24 hour manned control room
containing a GQ6ZA Six Zone
Annunciator
Perimeter Protection
GD5000-1 Analyser
GDALPHA Sensor fitted to fence
using GQTY-1 tie wraps every
2.4m
200mm
1m
Zone 1
Four pair signal cable carrying 12V
dc to the Analysers and audio alarm
and tamper signals back to the
Annunciator
GQCOMBO GEO
MULTI FUNC JB
OR EOL
GQCOMBO GEO
MULTI FUNC JB
OR EOL
GD5000-1
Analyser
GDALPHA
Sensor looped
the gate
GDGLK-A
Gate loop kit
GQFC-9 feeder cable in
ducting under gate
03/12
GQCOMBO GEO
MULTI FUNC JB
OR EOL
Zone 2
Intruder Catalogue
Chapter 18 Page 1
Intruder_Ch18_PerimProctect:Layout 1 20/03/2012 10:34 Page 2
Chapter 18 - Perimeter Protection
Product Codes
Defensor External Analysers
External Fence Protection
GD5000-1
Single Zone External Analysers
* For use with GDALPHA &
GDALPHA-FAC sensors
GD5000-2
Dual Zone External Analysers
* For use with GDALPHA &
GDALPHA-FAC sensors
Defensor Sensors
GDALPHA-50
Alpha Precision Sensor Cable
50 M drum only
GDALPHA-100
Alpha Precision Sensor Cable
100 drum only
GDALPHA-200
Alpha Precision Sensor Cable
200m drum only
Termination for Defensor System
GQCOMBO
GEO MULTI FUNC JB OR EOL
* Includes fixings
Chapter 18 Page 2
Intruder Catalogue
03/12
Intruder_Ch18_PerimProctect:Layout 1 20/03/2012 10:34 Page 3
Chapter 18 - Perimeter Protection
Building Protection
Features
• Can be fitted to new or existing walls, cladding and roofs
• 24 hr detection before intruder gains entrance to building
• Highest intruder detection level with lowest false
alarm rate
• Audio as standard with Annunciator or PC
• Can be integrated with CCTV and access control systems
• Can be integrated with PC based alarm management
software
Building Protection
Solid building construction is an effective initial deterrent to
intruders. However, the determined intruder can breach any
type of building fabric, often by breaking through.
Many electronic security systems focus on detecting
intruders after entry to the building. This often alerts police
or security too late to be able able to prevent an intruder
from achieving his objective. Intruders make the most of the
time delay between entering the building and response by
security staff or police following a subsequent alarm
activation.
Geoquip’s guardwire and Impactor systems are designed
to pick up vibrations as soon as contact is made with the
building. A security system which incorporates either
system will alarm as soon as an attack starts. During the
time taken to breach the fabric, the area of attack can be
located, security staff mobilised and CCTV, lights and sirens
activated.
This means that the control of the situation stays with the
security service and the attack can often be prevented.
A further advantage of early detection is the potential for
saving the building from repairs which are costly, represent
a security risk while awaiting repair and weaken the
defenses in further attacks.
By detecting the first contact made by an intruder,
Guardwire and Impactor are ‘primary’ detection systems.
Overall security can be enhanced by secondary detection
systems, such as Infra-Red and Microwave beams, which
can track intruders inside the building.
NOTE: On larger, more specialised projects, please contact Geoquip for prices on non-catalogue parts such as FAC + HS parts call Bernie Alphonso on 07866 494 198 - UK South or Neil Peart - 07836 211 480 - UK North
Building Protection
GQCOMBO GEO
MULTI FUNC JB
OR EOL
ADT Alarm
control panel
GW500-2
Analyser
Zone 2 on
cladding
GDALPHA Sensor in conduit fitted
to building fabric
Zone 1 on
blockwood
GQFC-11 five pair and GQFC-12 ten pair signal cables carrying 12V do to the Analysers
and audio, alarm and tamper signals back to
the alarm panel
GQFC-9 Feeder cable over
roller shutter door
GQCOMBO GEO
MULTI FUNC JB
OR EOL
03/12
GQCOMBO GEO
MULTI FUNC JB
OR EOL
Intruder Catalogue
GQCOMBO GEO
MULTI FUNC JB
OR EOL
GDALPHA-TJ Sensor fixed Impactor
directly to blockwood
Analyser
Chapter 18 Page 3
Intruder_Ch18_PerimProctect:Layout 1 20/03/2012 10:34 Page 4
Chapter 18 - Perimeter Protection
Product Codes
Cables & Conduits
Guardwire Analysers
GW500-1
Single Zone Internal Detection Analyser:
* For use with GDALPHA-TJ sensors
GW500-2
Dual Zone Internal Detection Analyser:
* For use with GDALPHA-TJ sensors
* FDual channel adjustment with alarm,
tamper, audio and self test as standard
Fixings
GQSA-3
8mm HALF SADDLE
* For use with GQCL-2
* For internal use with GDALPHA-TJ
GQCL-2
Clips
* For use with GQSA-3
* For internal use with GDALPHA-TJ
per box of 100 only
659.001.022
Power Supply Unit
12VdC 1 amp D.C. PSU
Guardwire Sensors
GDALPHA-TJ-50 Guardwire Sensor
*
*
*
*
*
*
For internal use - fixing to walls or cladding
Toughened outer jacket
Direct Fix
Heavy duty protection
Includes saddles & chips
50m drum only
Power Supply Unit
12v 7 ampere
GDALPHA-TJ-100 Guardwire Sensor
*
*
*
*
*
*
For internal use - fixing to walls or cladding
Toughened outer jacket
Direct Fix
Heavy duty protection
Includes saddles & chips
100m drum only
Guardwire Termination
GQCOMBO
GEO MULTI FUNC JB OR EOL
* Includes fixings
Chapter 18 Page 4
Intruder Catalogue
03/12
Intruder_Ch19_PSU's:Layout 1 20/03/2012 10:37 Page 1
Chapter 19 - Power Supply Units
Power Supply Units and Batteries
We have a number of power supply units and batteries to suit your needs.
Features
•
•
•
•
•
•
•
Power Supply Units
Elmdene Range
The EN range of standalone power supplies from
Elmdene have been specifically designed to provide a
comprehensive and flexible range of options for Intruder
Systems complying with PD6662: 2004/prEN50131-1.
The Power Supplies comply with the requirements of
EN50131-6.
EN50131-6 Type A compliant
EN50131 Environmental Class II
Fault Status monitoring
High Efficiency Circuit Design
Comprehensive output voltage and current protection
Deep Discharge Protection
Lid and Rear Tampers
The Power RIO can be used for the G2-20 & G2-44 panels
as well as the G3 range. It is also backwards compatible
with the existing Galaxy Classic range.
Honeywell Galaxy Range
The Galaxy range consists of 3 products. Two versions sit
on the data bus - one with a RIO fitted and the other
without. There is also a standalone version that does not
contain a RIO.
The Galaxy series 3 Power Supply unit consists of 2
modules, the Power Block and the Control Unit. The PSU
can be connected to the G3 control panel via the RS485
(AB) line. The PSU can be used in place of a standard RIO
to overcome power problems that arise when the additional
Rio is fitted distant to the control panel.
Note: Standby periods for power supplies are:
• Grade 1 and Grade 2 = 12 hours
• Grade 3 and Grade 4 = 24 hours
Technical Specification
Product
EN2-7B
EN2-17B
EN3-7B
EN3-17B
P026-01-B
EN3-34-R
G13801N-A
Case Size
Max Output
Battery Size
B
B
B
B
B
B
A
1
Amp
1.4 Amp
1
Amp
1.4 Amp
2.75 Amp
3.00 Amp
1 Amp
7Amp
17Amp
7Amp
17Amp
17Amp
17Amp
7 Amp
EN 50131
Grade
2
2
3
3
3
3
N/A
330
330
330
330
330
330
200
Size
H/W/D
x 355 x 80mm
x 355 x 80mm
x 355 x 80mm
x 355 x 80mm
x 355 x 80mm
x 355 x 80mm
x 230 x 80mm
Product Codes
EN2-7B
EN2-17B
EN3-7B
EN3-17B
03/12
Elmdene EN 50131 Grade 2 PSU in
clamshell box for use with all external
signalling devices. Uses 7Ah battery.
Elmdene EN 50131 Grade 2 PSU in
clamshell box for use with all external
signalling devices. Uses 17Ah battery
Elmdene EN 50131 Grade 3 PSU in
clamshell box for use with all external
signalling devices. Uses 7Ah battery
Elmdene EN 50131 Grade 3 PSU in
clamshell box for use with all external
signalling devices. Uses 17Ah battery
P026-01-B
G13801N-A
Honeywell Power Rio. Grade 2/3 2.75 PSU
with a RIO. Provides equal current for
power output and battery charging. Sits
on the data bus.
Elmdene Grade 2/3 3.0A PSU without a
Rio. Standalone version that does not sit
on the bus. 2 outputs for battery and
mains faults.
Elm Switchmode 12V 1AMP Non EN PSU
Intruder Catalogue
Chapter 19 Page 1
EN3-34-R
Intruder_Ch19_PSU's:Layout 1 20/03/2012 10:37 Page 2
Chapter 19 - Power Supply Units
Features
• Fault outputs
• On Board Rio
• EN50131 Grade 3
Power Rio
This Power RIO (P026-01-B) can be used for the G2-20 &
G2-44 panels as well as the G3 range. It is also backwards
compatible with the existing Galaxy Classic range. The
Galaxy series 3 Power Supply Unit consists of 2 modules,
the Power Block and the Control Unit. The PSU can be
connected to the G3 control panel via the RS485 (AB) line.
The PSU can be used in place of a standard RIO to
overcome power problems that arise when the additional
RIO is fitted distant to the control panel. A 6-way jumper
lead connects the Power Block to the Control Unit.
The PSU has 8 zones and 4 outputs. Addressing is identical
to that described for RIO Modules.
FAULT OP AC: This is an open collector transistor which is
normally off. The output is activated by an AC failure.
FAULT OP BAT: This is an open collector transistor which is
normally off. The output is activated by a Battery Low or
Battery Fail condition.
FAULT OP POWER: This is an open collector transistor
which is normally off. The output is activated by low voltage
present in +12V1, +12V2 or +14.5V.
Battery
The minimum capacity battery to supply the PSU is
1x 7Ah. The maximum capacity battery to supply the
PSU is 2 x 17Ah.
Note: ADT's preferred option is to use 1 x 17Ah battery.
Standby periods for power supplies are:
•
Grade 1 and Grade 2 = 12 hours
•
Grade 3 and Grade 4 = 24 hours
Standby period for Grades 3 & 4 is halved if PSU Fault is
signalled to the ARC.
Product Code
Technical Specification
Electrical
P026-01-B
(Based on 34 AH battery and UK grade 3 compliance)
Input voltage:
Output voltage:
(nominal)
Output Current:
(max)
Operating Temp:
Aux 1 & Aux2
Output voltage
(nominal):
Output current:
230Vac(+10%/-15%)@50Hz
13.8V & 14.5V
3.0A
-10°C to +40°C
13.8V
14.V
0.15 (when using this current, the
AUX1 & AUX2 currents will be
reduced by an equivalent amount).
Battery Charge
Current (max):
1.4A
Maximum ripple voltage less than 100mV
Fuses
F1 (14.5V)
500mA - 20mm anti-surge
F2 (Battery)
1.6A - 20mm anti-surge
F3 (Aux1)
1.0A - 20mm anti-surge
F4 (Aux2)
1.0A - 20mm anti surge
Chapter 19 Page 2
ICP Galaxy Grade 3 compliant smart
2.75A PSU with RIO
EN50131 Compliance
This product is suitable for use in systems
designed to comply with EN50131-1:2004
Security Grade - 3
Environmental Class - II
Power Supply Type - A
Intruder Catalogue
03/12
Intruder_Ch20_RadioCooper:Layout 1 20/03/2012 10:39 Page 1
Chapter 20 - Radio Equipment - Cooper Security
Radio Equipment
The use of radio transmission within an Intruder Alarm System can be beneficial where cabling of devices is not practical.
A simple transmit/receive configuration can be used to interconnect conventional devices in out-buildings to the main alarm
system.
In addition, portable personal attack buttons enable personnel to summon assistance from any location within a building. It should
be noted that the effectiveness of a radio system is dependent on the building construction and background noise. It is
recommended that a radio test is carried out before installing this type of system.
Features
•
•
•
•
Full range of transmitters and receivers for all applications
5 types of PA transmitter including ‘tilt’ switch unit
2 channel receiver compatible with all alarm control panels
8 channel (expandable to 64 channels) receiver, mains or
12V powered
• Fully programmable, multi option transmitter
Scantronic Radio Equipment
Scantronic Radio Systems are an integrated range of FM
transmitters and dual conversion superheat receivers that
feature the latest SMD technology and long life LTC
batteries. The entire range is fully approved by the DTI for
use on the professional security frequency, 868MHz.
HVAC Plant Monitor
Use the 703recur-00 transmitter connected to the standard
monitor output contacts on heating, ventilating and air
conditioning plant so as to transmit any abnormal conditions
to gatehouse or building managers.
The Scantronic Radio products can be used in many
different applications such as;
‘Lone Worker’ Protection System
Use a 701recur-50 pendant or a 762recur-50 hand held
panic button with a 762recur-00/768recur-50 receiver
connected directly to a conventional intruder alarm panel, to
provide a means of summoning help if a ‘lone worker’
should become ill or injured whilst working alone.
A special version hand held panic button (706recur-00), has
an extra safety feature built in; a mercury tilt switch is
included and will automatically activate the transmitter
should the worker fall further than a nominal 45 degrees,
from the vertical, for longer than eight seconds. This is of
particular importance to those people working in areas
where there is a risk of falling or being overcome by toxic
fumes.
Alarm Retransmission
Use the 703recur-00 or 734recur-00 transmitters to collect
the alarm output from detectors or remote control units, and
transmit them back to the control unit of the main building
system.
This can be very useful in areas where there are
outbuildings or remote garages.
Each individual can have full local control, via its own control
panel, but any alarm signals can be brought into the main
security system.
Door/Barrier Control
Use the 762recur-00/768recur-50 receiver, 701recur-50
pendant or 726recur-60hand held transmitter to remotely
control electric doors, gates, lifting barriers or lights.
Particularly useful where it is difficult or expensive to run
cables from a control point to the remote door, gate, barrier
or lighting units.
Emergency Panic Button
Use a 726recur-60 hand held panic button with
762recur-00/768recur-50 receiver, connected to a
conventional burglar alarm control panel to provide a
fully mobile panic button facility. Ideal for use in homes,
garage forecourts, where cash is moved around or where
you have guards left alone in industrial premises.
03/12
Benefits:
8 Channel Programmable receiver expandable to 32 zones
Transmitter “Learn” coding via infra-red or radio (16,000,000
permutations.) Auto-recognition of transmitter type and auto
configuration. Two alarm output relays. Five status output
relays: low battery, jamming, supervision, Aux fail, tamper.
Integral field strength meter. 16 LED indicators, Expandable
up to 32 zones using 769 eur-00 (8 channels per 769R unit,
max three units0. 8 relay expander card 8600 can be fitted
to both 768R and 769R. Anti-tampered polycarbonate
housing. Features AE2 dual diversity receiver technology
and antenna. Provision for external antenna via BNC socket.
Intruder Catalogue
Chapter 20 Page 1
Intruder_Ch20_RadioCooper:Layout 1 20/03/2012 10:39 Page 2
Chapter 20 - Radio Equipment - Cooper Security
Narrowband 868.6625 MHz Transmitters and Receivers
Programmable, multi-function 4 channel transmitter (including 792recur-00antenna)
Programmable, multi-function 4
channel transmitter (including
792recur-00 antenna)BNC socket for
external antenna, plus 792 1/4 wave
aerial. 12VDC and/or 2 x AA nonrechargeable alkaline batteries.
Polycarbonate housing 2 indicator
LEDs.
Technical Specification
Description Dimensions (mm WxHxD)
105 x 150 x 30
Product Code
703REUR-00
Technical Specification
Description Dimensions (mm
WxHxD)170 x 45 x 30
Product Code
706REUR-00
4 channel
transmitter
Lone worker unit with addition PA function
Lone worker unit with addition PA
function. Man-down signal with
integral buzzer. PA uses double
action button to avoid false alarms.
Belt clip. Long range. Sealed unit,
non-replaceable Lithium battery.
Lone worker
and PA
transmitter
Double action personal attack transmitters
Double action PA transmitter, lock to
prevent accidental operation
(includes belt clip). Sealed-unit,
non-replaceable lithium battery.
Product Codes
726REUR-50
Technical Specification
Description Dimensions
(mm WxHxD)
710REUR-00
726REUR-60
Long range PA
Transmitter
PA
Transmitter
Dual
Operational PA
transmitter
726REUR-50 Long range PA
transmitter: 170 x 45 x 30
726REUR-60 PA transmitter:
100x 45x30
710REUR-00 Dual Operational
PA transmitter:
58 x40 x16
Part Number
710REUR-00
Dual Operation Personal
attack transmitter
726REUR-50
Extended range,
dual operation personal
attack transmitter
726REUR-60
Standard, dual operation
personal attack
transmitter
Channels
1
1
1
Operating frequency
868.6625MHz @ 20Khz bandwidth. CE tested to I-ETS 300 220
Description
Transmission Power
10mW
10mW
10mW
Free Space Radio Range
Power Supply (Battery)
>1000
3v CR2 Li
>1000
3.6v Li 1/2 AA Not
user replaceable
>600
3.6v Li 1/2 AA Not user
replaceable
Typical Battery Life
3-5 years
3-5 years
3-5 years
Temperature Range
-10 to +55°C
-10 to +55°C
Dimensions
58 x 40 x 16
163 x 46 x 30
104 x 46 x 30
Weight
34gm
65gm
65kgm
Colour
Dark Grey
Dark Grey
Dark Grey
Compliance
Chapter 20 Page 2
EN50131-2 Grade 2, EN610000-6-3:2001, Environmental Class II
Intruder Catalogue
03/12
Intruder_Ch20_RadioCooper:Layout 1 20/03/2012 10:39 Page 3
Chapter 20 - Radio Equipment - Cooper Security
Narrowband 868.6625 MHz Transmitters and Receivers cont’d
4 Channel Door Contact
4 Channel Door contact with integral
magnetic contact (magnet supplied).
Alarm and tamper signals. )) Version
provides inputs for shock detector
and roller shutter. 1 x CR2
replaceable battery (supplied).
Technical Specification
Description Dimensions (mm
WxHxD)
734R EUR-00:
35 x 90 x 24
734R EUR-01:
35 x 90 x 24
Product Code
734REUR-00
Technical Specification
See detail in table below
Product Code
762REUR-00
Door Contact
+ shock
sensor
2 Channel Programmable receiver
2 channel programmable receiver.
Transmitter ‘Learn’ coding via
infra-red or radio (16,000,000
permutations). Auto recognition of
transmitter type and auto
configuration. Two alarm output
relays. Five status output relays: low
battery, jamming, supervision, Aux
fail, temper. Integral filed strength
meter. Eight LED indicators. Features
AE2 dual diversity receiver technology and
antenna. Provision for external Power
9-15 VDC, 55mA max.
Channels
LED Indicators
Internal Display
Compliance
Radio Section
Antenna
Transmitter Learn
Input Power
Supervision Interval
Outputs 1 and 2
Status Outputs
Dimensions
Weight
03/12
2 channel
programmable
receiver for
700R series
2 channels, up to four devices per channel (2 x single channel or 1 x 2 channel transmitter
recommended)
8 showing Power; transmitter low battery; supervision; jamming; channel activated; tamper
activated
Two by seven-segment LED. Visible with case open
Product is tested to 1995/5/EC R&TTE Directive, EN50131-3 Security grade 2
environmental class II
Operating Frequency868.6625MHz at 20kHz bandwidth. I-ETS 300 220 CE tested to I-ETS
300 339 (draft standard)
Integral AE2 dual diversity antennae and receiver; BNC connector for connection of any
remote antenna
Auto recognition of type and auto configuration via radio or LED (16,000,000 permutations)
9-15Vdc Quiescent current 55mA. All outputs active 200mA
Programmable 4 minutes, 29 minutes or no supervision
Relay contacts, NO/NC, 2A at 25Vdc
5 x Relay contacts, NO/NC, 2A at 25Vdc
183 x 129 x 32 mm (HxWxD)
0.35Kg
Intruder Catalogue
Chapter 20 Page 3
Intruder_Ch20_RadioCooper:Layout 1 20/03/2012 10:39 Page 4
Chapter 20 - Radio Equipment - Cooper Security
8 Channel Programmable receiver Expandable to 32 Zones
Transmitter ‘ Learn’ coding via
infra-red or radio (16,000,000
permutations). Auto-recognition of
transmitter type and auto
configuration. Two alarm output
relays. Five status output relays: low
battery, jamming, supervision, Aux
fail, tamper, Integral field strength
meter.
Eight LED indicators. Features AE2
dual diversity receiver technology
an antenna. Provision for external
antenna via BNC socket.
Anti-tampered polycarbonate
housing.
Technical Specification
Dimensions (mm WxHxD)
768R EUR-50: 163 x 265 x 81
769R EUR-50: 163 x 265 x 81
8600R EUR-00: 60 x 130 x 20
Product Codes
768REUR-50
769REUR-50
08600EUR-00
Expandable 8
channel
receiver
8 Channel
expander for
768R
Relay card for
768R and
769R
Antennae for 700R
Antennae for 700R Connection via
BNC socket
Technical Specification
Dimensions (mm WxHxD)
792R EUR-00:
110 x 15
794R EUR-00:
1200 x 30
797R EUR-00:
200 x 22
Product Codes
792REUR-00
794REUR-00
797REUR-00
Chapter 20 Page 4
Intruder Catalogue
Indoor 1/4
wave antenna
703R and
790R
Indoor/outdoor
8 x 1/2 we've
antennae with
3m coax cable
and fixing
bracket
Indoor/outdoor
1/2 wave
antenna with
3m coax cable
and fixing
bracket
03/12
Intruder_Ch21_RadioEMS:Layout 1 20/03/2012 10:40 Page 1
Chapter 21 - Radio Equipment - EMS
EMS
The IRIS Radio Personal Attack system is ideal for use in all types of financial, industrial or commercial premises.
This system is especially ideal where staff need the security of a personal attack alarm with the freedom of mobility.
Features
• Completely wire free
• Individually identifiable
• Uniquely Coded Parts
UHF System 7000 Intelligent Radio Information System (IRIS)
Up to 256 transmitters, each individually identified by the
receiver make up the standard IRIS UHF personal attack
system. Each transmitter is uniquely coded and cannot be
duplicated.
The IRIS radio system supports numerous other integrated
devices for gathering information from fixed or portable
alarm inputs. This information can then be displayed locally
on the receiver or used to send onward signals via an alarm
transmitter. The transmitters are also suitable for fixed
positions, and, as the system is devoid of interconnecting
wiring, any alteration can be carried out quickly and
inexpensively. False alarms caused by damage to traditional
24 hour live personal attack wiring circuits are totally
eliminated.
Every event is time and date stamped, held in an incident
log and viewable from the LCD display. After resetting, the
events are then transferred to the historical log, also
viewable from the display, or via an optional plug-in printer.
Up to 256 transmitters, each individually identified by the
receiver make up the standard IRIS UHF personal attack
system. Each transmitter is uniquely coded and cannot be
duplicated.
The transmitters are also suitable for fixed positions, and, as
the system is devoid of interconnecting wiring, any
alteration can be carried out quickly and inexpensively.
False alarms caused by damage to traditional 24 hour live
personal attack wiring circuits are totally eliminated.
EMS Brackets
Product Code
Ems Bracket for 7930
7206
asset protection and 7971
single button PA
transmitter
Product Code
Ems Bracket for 7900 PA
7207
Handset
Product Code
Ems Bracket for 7500 PA
7507
Handset
03/12
Intruder Catalogue
Chapter 21 Page 1
Intruder_Ch21_RadioEMS:Layout 1 20/03/2012 10:40 Page 2
Chapter 21 - Radio Equipment - EMS
Product Code
609.011.179
Product Code
7215-SL-BB
EMS 7911/B H/WIRED PA
HSBC
Product Code
609.011.182
EMS 7970 Dual
Action pendant
Ems 7215 Software and
Bluestrobe Kit
(Barclays Bank)
EMS IRIS UHF
Product Code
7256-PLUS
Product Code
7500-2
Product Code
7573
Product Code
7920
Product Code
7920-PB
Product Code
7920-PC
Chapter 21 Page 2
EMS IRIS UHF
Multi Funcion RF REC
EMS IRIS UHF hand TX 2
Button
EMS 7207 TX Mounting
Bracket
Product Code
7328
Product Code
7500-3
Product Code
7723
Product Code
7920-AS
EMS IRIS UHF
UNIV ContactTX
EMS IRIS UHF Contact
TX PB
Product Code
7920-PB-BB
Product Code
7K67J
EMS IRIS UHF
Contact TX Pull Cord
Intruder Catalogue
EMS IRIS UHF
HIgh Gain Aerial
EMS IRIS UHF hand TX
EMS IRIS UHF
Transponder
EMS IRIS UHF
Contact TX PB AS
EMS IRIS UHF Contact
TX PB Barclays Bank
Version
6 volt battery for use with
7900 Personal Attack
handset
03/12
Intruder_Ch21_RadioEMS:Layout 1 20/03/2012 10:40 Page 3
Chapter 21 - Radio Equipment - EMS
Features
• Dual action buttons for “full alarm” transmission
• Secondary single action button for local or ancillary
alarm
• Optional 3 button or any combination of the 3 buttons
• Operation for full alarm generation
UHF System Single Zone Receivers
The 7703 radio personal attack system is ideal for use in all
types of financial, industrial or commercial premises where
staff need the security of a personal attack alarm and also
the freedom of mobility. They are also suitable for fixed
positions and, as the system is devoid of interconnecting
wiring, any alteration can be carried out quickly and
inexpensively. False alarms caused by damage to traditional
24 hour live personal attack wiring circuits are totally
eliminated.
Consisting of a compact receiver unit and up to 48
transmitters, the standard 7703 UHF personal attack
system has a typical range up to 250 metres.
Technical Specification
Product Code
Dimensions:
Operating Freq:
609.011.103
Supply Voltage:
Power:
Inputs Radio Transmitters:
Outputs:
03/12
230H x 150W x 68D mm
458.5 to 458.8MHz (MPT
1329) Channel spacing
25KHz
12V or 24Vd.c.
60mA standard at 12V
All transmitters including the fixed money clip are powered
by an Alkaline battery giving a minimum of one year battery
life.
EMS 7703 UHF single zone receiver
7900 Portable Tx
7910 Money clip Tx
2 relay outputs with 1A
24Vd.c. change over
contacts [email protected]
Max (28VA)
Intruder Catalogue
Chapter 21 Page 3
Intruder_Ch21_RadioEMS:Layout 1 20/03/2012 10:40 Page 4
Chapter 21 - Radio Equipment - EMS
This page is left intentionally blank
Chapter 21 Page 4
Intruder Catalogue
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 1
Chapter 22 - Signalling
Signalling
Intruder Alarm Systems provide the optimum protection when used in conjunction with an Alarm Receiving Centre. In the event of
an alarm condition the Intruder System will send a signal to the Alarm Receiving Centre who will then take appropriate action, e.g..
summon police, fire brigade etc.
There are several ways of transmitting the signal from the site to the Alarm Receiving Centre. The method of signalling will depend
on the level of risk associated with the premises.
Selecting Appropriate Signalling Device
Types of Signalling
Standard Intruder Alarm Control Panels have fitted as
standard a digital communications device which signals
over a standard PSTN (Public Switched Telephone
Network) Line. If the line is cut then the Central Station is
not notified, there is only local indication of a line cut. This
type of signalling is adequate for Level 1, Low Risk
Residential Customers.
RedCARE
RedCARE is a polled device signalling over the PSTN.
If the line is cut then both the Customer and the Central
Station are informed.
Digital Communicators
Digital Communicators offer a cost effective means of
transmitting signals to an Alarm Receiving Centre. They
connect to a standard telephone line (PSTN) and in the
event of an alarm “phone up” the Alarm Receiving
Centre and exchange code information. If the
telephone line is cut the Alarm Receiving Centre is NOT
notified and the system reverts to local indication only.
As all signalling devices are wired-in they require to
placed in a housing. You will require an Elmdene 12Vdc
1Amp PSU.
EN2-7B
EN2-17B
EN3-7B
EN3-17B
RedCARE GSM
RedCARE GSM works in the same way as DualCom
GSM just on a different GSM network. If using
RedCARE GSM you must test the signal strength
where the control panel will be located.
In addition, they use battery PS-1270, PS-12170.
DualCom GPRS
DualCom GPRS, from CSL DualCom Limited, is an
intruder alarm signalling device that uses both the
Vodafone network and your telephone path to transmit
intruder and personal attack signals at high speed.
Once the alarm is confirmed as genuine, police are
notified. Utilising two signalling paths ensures that
DualCom dual-signalling will always have a back-up
path in the event of an accidental or deliberate fault on
either path.
IP Signalling
IP uses the internet to carry security communications
instead of the old switched telephone network. This
means that vastly more information, of vastly different
kinds can be sent without the need for dedicated lines;
information such as voice, data and high definition
CCTV. It also allows that information to be two-wa, so a
monitoring centre can communicate with a remote site,
interrogate it's health, control cameras and even
conduct remote maintenance. There's also
considerable pressure from the telecommunications
companies themselves or the security industry to
switch to IP. Because IP uses less bandwidth than
conventional methods, it frees up capacity to be used
for other purposes such as on-demand television.
Indeed much of the European telecom network is in
the process of planning the withdrawal of the services
that makes non-IP security communications possible.
03/12
Intruder Catalogue
Chapter 22 Page 1
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 2
Chapter 22 - Signalling
Features
• 11-Zone 5GSTU consists of a stand-alone base model
5GSTU
• RedCare is a Secured By Design produce and as such
has gained Police Preferred Specification status. This was
achieved after testing against and meeting the highest
grade (Grade 4) of European Standard 50131
• No need for an extra telephone line (a Modem Compatible
Device may be required if fax and data services are to be
used on same line)
• Active, continuous 2-way monitoring - 24 hours a day,
every day of the year
RedCare 5g STU 11 pin
The 5th Generation Subscribers Terminal Unit (5G STU) is a
communicator for signalling alarm signals between a
protected premises and an Alarm receiving centre (ARC).
The 5G STU uses the extremely reliable BT redcare network
to convey the messages over a redcare enabled BT
analogue PSTN line. Even if an intruder cuts the line and
jams the radio signals an alarm message will still rapidly be
sent to the ARC.
The 5G STU is fully compatible with BT’s 21CN network
upgrade program and connects to any BT redcare enabled
telephone line. The 5G STU is fully ADSL compliant and
does not require an additional ADSL microfilter.
The STU has 11 screw terminal inputs plus tamper (T) & AC
fail (F) for connection to the monitored equipment such as
an alarm panel. (3 inputs on the Fire STU) (Note on GSM
STU pin 8 is reserved for low signal strength, and pin 10 &
11 maybe reserved for path test alarms in BSIA mode
(F7=3) The alarm inputs are triggered by changing their
voltage state.
Output Relays
Three output relays are provided: Control, Return Path
Signalling (RPS), and Line Fault. The use of any, or all, of
these functions is optional. For a basic installation these
outputs are not required.
Note: If an output is to be connected to a device which produces transient
voltages, such as a bell,the device should be suppressed using a suitable
protection diode.
Control output relay (CTRL)
This relay can be switched on or off by the alarm receiving
centre (ARC) operator by sending and output ON or output
OFF command to the STU through the redcare network.
The output can typically be used to remotely reset an alarm
panel, or to operate other devices such as lights or door
latches at the site.
Line Fault output (LF)
The Line Fault Output is used to indicate, at the protected
premises, that either or both the GSM and landline (PSTN or
Private Wire) communication paths have failed. The ‘Line
Fault’ relay contacts (Normally Open, Common, Normally
Closed) are available for connection on TB1. The maximum
current rating of the relay contacts is 1 Amp.
Return Path Signalling (RPS)
The RPS output is used to indicate, at the protected
premises, that the opening/closing signal has been sent to,
and acknowledged by, the Alarm Receiving Centre.
To use the RPS function, at least one of the alarm inputs
must be designated as an opening/closing channel (usually
channel 4). The RPS output will activate when an opening or
closing signal is detected. It will de-activate when the
opening or closing signal has been acknowledged by the
Alarm Receiving Centre. It is allowable to have more than
one input designated as an opening/closing channel, but
each must be acknowledged to de-activate the RPS output.
The RPS relay contacts (Normally Open, Common, Normally
Closed) are available for connection on terminal block TB1.
To use this option, a warning device such as a piezo bleeper
or external strobe light should be connected through these
contacts. The maximum current rating of the relay
contacts is 1 Amp
Technical Specification
Product Codes
Pin alarm inputs:
Logic High
+2.5V to +30V
Logic Low
-0.5V to +0.8V
:
Logic level outputs:
Logic High
3.0V @ 560mA max
Logic Low
0.4V @ 280mA max
With respect to the 0V terminal on TB1.
Power Rating:
5G GSM 12Vdc 160mA mean 350mA peak
5G Classic 12Vdc 80mA
5G Fire 24Vdc xxmA
Environmental:
Operating ambient temperature
+5°C to +40°C
Relay contacts:
30V 1A Max
Physical
Size
168 x 115 x 36mm
5G-STU
7525
11 pin STU
Prom for 3GTSU, PakNet and Scantronic
digital communicators
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 3
Chapter 22 - Signalling
Features
•
•
•
•
Ideal for Businesses and Residential
EN501331 Grade 4
Continuous Monitoring
Two signalling paths, PSTN & GSM
RedCare 5G-GSM
RedCARE GSM is a combined PSTN Subscriber Terminal
Unit and wireless alarm reporting device for the BT
RedCARE service.
This STU is to be used for new installations but can be used
for old control panels as replacements, as it incorporates
backward compatibility. BT Redcare GSM has an ATS rating
of 5 as per table 11 of “prEN50131-1 2004 for the primary
path and ATS rating of 4 for the radio path and complies
with the requirements of PD6662:2004.
The RedCARE GSM system is designed to provide a backup
communications path for the single land line connection to a
premises. This allows alarms to continue to be transmitted
even in the event of a land line communications failure. The
Alarm Receiving Centre (ARC) will be able to continue to
monitor a premises following a land line failure. It also
allows line faults (as distinct from malicious line cuts) to be
more positively identified. A malicious line cut will usually be
accompanied by an intruder alarm transmitted over the GSM
path.
In addition, the GSM signal strength is constantly monitored.
Should this fall below a certain level then a GSM alarm will
be transmitted via the landline. This means that both
landline and GSM are constantly monitored and a failure of
one will transmit an alarm via the other.
Siting
When surveying the site please remember that the
RedCARE GSM unit operates in a similar way to an ordinary
mobile telephone, therefore any restrictions on the use of
mobile telephones in the area will also apply to the
RedCARE GSM unit. Premises such as hospitals, petrol
stations, airports, blasting areas etc. may operate mobile
telephone restriction in certain areas.
Signal Strength Testing
Prior to quoting a RedCARE GSM for a site, you should
carry out a signal strength test during your survey or
pre-installation site visit. This task requires the use of a
Cellnet digital GSM mobile telephone with the test
programme loaded. This enables you to find a suitable
location for the GSM STU.
If the signal strength is weak, try to find a better position
for the GSM STU unit. If required, a high gain extension
antenna with an extension cable is available (608.009.188).
ATS Test Mode
GSM STU EV will be supplied with a plug-in NVM chip
already fitted an programmed to enable the new Alarm
Transmission System Test functionality. This chip can be
simply removed before installation to maintain compatibility
with older systems.
In ATS Test mode, pin alarms 8,10 and 11 are reserved an
cannot be used for intruder alarms as they will be ignored.
Pin 10 (alarm and reset) signals a GSM path successful
communication, Pin 11 (alarm and reset) shows a
successful landline communication, pin terminal 8 (Pin 11
SK2) is used to initiate the ATS Test. Pin Alarm 8 will still
indicate local GSM signal strength issues.
For Plug-in units, a new jumper needs to be set to (LK3) to
allow pin 11 to be used as the ATS test pin.
Always check that the chosen site is free of such restrictions
and advise the end user so that they are aware, should any
come into force in the future.
Technical Specification
Dimensions:
Power:
Inputs:
Comms Triggers:
Operating Temp:
03/12
HXWXD
308 x 383 x 95mm
(not including Aerial
230 Vac)
12Vdc, + VE removed in Alarm
-10 ° to 55 °C
Product Codes
5G-GSM
608.009.188
WHITESTICK
EXT-CABLE
Intruder Catalogue
RedCARE GSM STU combined dual
signalling unit (for use on new
installations)
GSM STU 5 metre extension antenna for
use with 608.009.187
WHITESTICK extension aerial
10 metre extension cable
Chapter 22 Page 3
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 4
Chapter 22 - Signalling
Features
• Multiple signalling paths, GPRS, telephone and/or IP/TCIP
(Internet, broadband or LAN connectivity)
• High-speed signalling on GPRS path
• Dual signalling is preferred by Insurance companies and
Police
• Meets all insurance grades (low to high risk)
• GradeShift® to remotely up/down grade for increased
insurance specification
• No need for dedicated telephone line, can share with
existing
telephone line or network
• Reports signalling path failure in seconds
• Supplied fully programmed
• Comes with world SIM
CSL DualCom - GPRS Grade 4 (Gradeshift)
DualCom GPRS is an advanced auto-dialling Digital
Communication Device for secure alarm reporting. It is
supplied as a “dual path” Alarm Transmission System (ATS)
that when fully installed will meet Grade 2, 3, or 4
installations as specified in the EN50136 standard for ATS.
DualCom GPRS can transmit alarm signals to an Alarm
Receiving Centre via the radio GPRS path, the radio GSM
path, the customer’s wired LAN network (IP) in connection
with the internet, and the PSTN (Public Switched Telephone
Network).
This aerial provides everything necessary to fit on the
metal/plastic alarm enclosure, on an internal wall up to 1m
away from the DualCom unit and on an internal/external
wall up to 5m + 1m away from the DualCom unit with the
addition of a 5m extension lead available separately. ( Part
number CS2056)
Now you can dispense with the DualCom external aerial,
(CS2057) as there is no need for it and as this new aerial
offers better attenuation over both the existing extension
and white box aerials there should be less incidents of bad
signal strength and less second visits to correct this.
With effect from November 1st 2008 all Dualcom GPRS
units will be sent out with a new aerial. This aerial will be
standard included with all the DualCom units replacing the
white boxed aerial currently supplied.
DualCom GPRS G2 Features
All the above features plus: Designed for lower risk premises
usually domestic or small commercial installations, G2 offers
an affordable dual signalling solution whilst providing future
proofing against the planned changes to the BT Network
(21CN – explained overleaf). It is also ideal for upgrading
digital communicators which offer limited protection and one
single path.
GRADESHIFT®
Imagine one product for all grades – G2, G3, G4 and Fire
With GradeShift® from CSL DualCom it’s a reality!
DualCom GPRS Fire Features
With 67% of fires occurring when premises are vacant
DualCom Fire fulfils an invaluable role with its ability to signal a
fire alarm whether the premises are vacant or occupied. The
quick and reliable despatch of an alarm is critical when dealing
with Fire signalling. It has a voltage range of 10 to 30 volts for
an easy installation and is compliant to BS5839 (the Fire British
Standard). DualCom Fire signals to the Alarm Receiving Centre
in seconds minimising damage to property whilst protecting
lives.
DualCom GPRS G4 Features
All the above features plus: Designed with the
highest risk premises in mind and is the ultimate
signalling solution for premium commercial
installations. DualCom G4 is compliant with
EN50131 Grade 4 (the most stringent of all
security regulations) ensuring maximum
insurance approval and loss protection. In
addition to this, DualCom G4 is polled every 3
minutes on all signalling paths so that you will
know of an intrusion at the earliest possible
instance. Its 96 hour memory log (explained
overleaf) provides an infallible record of onboard activity.
Chapter 22 Page 4
DualCom GPRS G3 Features
All the above features plus: Designed for
medium risk premises, DualCom G3 is ideal for larger
commercial installations and is approved by all leading
insurance companies for this grade of risk. It provides
enhanced polling in the form of Priority Polling™ (explained
overleaf) completely free of charge giving you extra peace of
mind. DualCom G3 is future proofed against BT’s planned
changes to their network and its unique Gemini Callback®
feature teamed with 21CN Mode® (explained overleaf) make
it an ideal choice if you wish to eliminate unnecessary
keyholder callouts.
Intruder Catalogue
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 5
Chapter 22 - Signalling
Priority PollingTM
Is available on all GPRS G3 products and can be switched
on when stock profile is high or premises enter a higher
category of Risk and require a higher degree of polling.
Gemini Call Back®
For additional peace of mind all DualCom products
incorporate this unique Callback feature. If a DualCom
fails to signal, our Gemini polling server will call the
DualCom over the GSM path (at no extra cost) to verify
that the DualCom is able to make a call before keyholders
get disturbed unnecessarily.
If there is no GPRS radio coverage at the proposed site,
the DualCom’s GPRS radio alarm reporting and polling
path will not operate.
If there is no GSM radio coverage at the proposed site, the
DualCom’s GPRS and GSM radio alarm reporting paths
will not operate.
Product Code
CS2412
CSL Dualcom GPRS Grade 4..comes
with world SIM
21CN Mode®
All DualCom products have a programmable 21CN mode®
whereby enhanced polling on the radio path will avoid
unnecessary keyholder contact from telephone or IP path
disruptions.
Memory Log
Keeps a record for the last 96 hrs of call traffic on-board
the DualCom.
Site Survey
It is strongly recommended that a site survey is conducted
prior to a installation of a DualCom GPRS to conform that
adequate GPRS signal strength is available at the site.
Before visiting the site, call CSL Technical Support. Ask for
a GPRS signal strength prediction. For this, you will need
to have the Postcode of the site available. This will tell you
if there is GPRS radio coverage at the proposed site.
For further information, contact CSL:
CSL Dualcom Limited
Salamander Quay West
Park Lane
HAREFIELD
Middlesex
UB9 6NZ
Tel: 01895 474 474
DualCom GPRS is supplied with a vodafone UK GPRS SIM
Card which can only be used in the UK on the Vodafone
UK GSM and GPRS networks.
Features
Priority Polling™
Gemini Callback®
21CN-MODE®
GradeShift® - Remote Grade Change up or down
Variable Voltage Input VVI – will accept 9v to 30v DC power
GSM Secondary Reporting Path
Managed Network
Insurance Specified
Memory Log (keeps a record of the last 96 hrs of call traffic
on-board the DualCom)
Free PSTN calls for polling and alarms
Polling Times
Fault reporting when any path fails Radio GSM/GPRS
Path
Landline/IP Path
G2
yes
yes
yes
yes
yes
yes
yes
n/a
G3
yes
yes
yes
yes
yes
yes
yes
yes
G4
yes
yes
yes
yes
yes
yes
yes
yes
GFire
-------yes
yes
yes
yes
yes
yes
yes
------yes
------yes
96 hrs
yes
96hrs
yes
G2
G3
3 mins
99 secs
3 mins 3 mins 3 mins
99 secs 99 secs 99 secs
Polling Frequency on the Radio path when PSTN and/or IP has failed
Polling frequency on the PSTN and/or IP when Radio path has failed
Fault reporting if both paths fail simultaneously
G4
GFire
5 hrs 15 mins* 3 mins
n/a
5 mins* 3 mins
24 hrs 1 hr
3 mins
3 mins
3 mins
3mins
* Average 10 – 20 mins expected. Note 1: Values shown are for alarm reporting, polling and system integrity alerts. Note 2: Grade 4 has
Priority Polling™ on both paths. Note 3: The Primary and Secondary paths can be any combination of GPRS/PSTN/IP/GSM. Note 4: All
values show the maximum specification possible from each technology.
03/12
Intruder Catalogue
Chapter 22 Page 5
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 6
Chapter 22 - Signalling
Features
• Two signalling paths, GPRS and telephone
• High-speed transmission on GPRS world SIM-UK Only
• Fixed tariff means unlimited transmissions and no hidden
charges
• Dual-signalling preferred by insurance companies and
police
• Meets insurance Grades 2 & 3 (medium-high risk
category)
• Can connect to any telephone network
• No need for dedicated telephone line, can share with
existing telephone line
• Reports telephone or GPRS failure in seconds
• Supplied fully programmed
• For fire installations, use DualCom Fire
DualCom GPRS Grade 3
Signalling Changes
DualCom GPRS, from CSL DualCom Limited, is an intruder
alarm signalling device that uses both the Vodafone network
and your telephone path to transmit intruder and personal
attack signals at high speed. Once the alarm is confirmed as
genuine, police are notified. Utilising two signalling paths
ensures that DualCom dual-signalling will always have a
back-up path in the event of an accidental or deliberate fault
on either path.
Dual-Signalling
DualCom GPRS is the newest member of the tried and
tested DualCom family. GPRS is a high-speed technology
used to send and receive ‘packets’ of data. CSL chose
Vodafone for the integrity of its performance in both
reliability and speed.
DualCom GPRS
A dual-signalling device helps to distinguish genuine from
false alarms and can therefore prevent your police response
time from dropping to a lower level or being withdrawn. It
also allows you to gain instant reinstatement of your Police
response should it have been withdrawn.
Additional Option
With the addition of a LAN (Local Area Network) card,
DualCom GPRS can convert to an IP (Internet) based
secondary path. And, if you’re not convinced that the
internet is the way forward for your business or you are
simply not ready, it can be plugged on at a later date whilst
running on the proven signalling paths of telephone line and
GPRS in the interim.
GPRS is charged as a fixed tariff, meaning the device can
send and receive an unlimited amount of data at no extra
charge. The use of this affordable new technology allows
CSL to bring dual-signalling to a market previously using
single-path technology on a cost basis. Dual-signalling, as
favoured by insurance and police, is the only way forward
when it comes to the protection of people and property.
Product Codes
CS2312
CS2351-00
CS2056
CSL Dualcom Grade 3 GPRS with world
SIM UK only
9 to 16 Channel Expander Card
CSL 5M extension lead for Dualcom GPRS
units
Additional Equipment required
PSU and Battery
Chapter 22 Page 6
Intruder Catalogue
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 7
Chapter 22 - Signalling
Features
• Two signalling paths, GPRS and telephone
• High-speed transmission on GPRS world SIM-UK Only
• High-speed transmission on GPRS Vodaphone SIM- ROI
only
• Fixed tariff means unlimited transmissions and no hidden
charges
• Dual-signalling preferred by insurance companies and
police
• Meets insurance Grade 2 (low-medium risk category)
• Remote upgrade available for increased insurance
specification
• Can connect to any telephone network
• No need for dedicated telephone line, can share with
existing telephone line
• Reports telephone or GPRS failure in seconds
• Supplied fully programmed
• For fire installations, use DualCom Fire
DualCom GPRS Grade 2
Grade 2 Dualcom GPRS unit from CSL (CS2322-00) is an
intruder alarm signalling device that uses both the Vodafone
network and the telephone path to transmit intruder and
personal attack signals at high speed. Once the alarm is
confirmed as genuine, police are notified.
Utilising two signalling paths ensures that DualCom
dual-signalling will always have a back-up path in the event
of an accidental or deliberate fault on either path.
DualCom GPRS Grade2 is the newest member of the tried
and tested DualCom family.
GPRS is a high-speed technology used to send and receive
'packets' of data. CSL chose Vodafone for the integrity of its
performance in both reliability and speed. GPRS is charged
as a fixed tariff, meaning the device can send and receive
an unlimited amount of data at no extra charge. The use of
this affordable new technology allows us to bring dualsignalling to a market previously using single-path
technology on a cost basis. Dual-signalling, as favoured by
insurance and police, is the only way forward when it
comes to the protection of people and property.
CSL Signal Test
The CS2366 is a Radio Test Set for use with GSM and
GPRS Radio Networks.
The Test Set will measure and display radio signal strength
received, plus levels of received of interference. With the
supplied aerial, it may be used to measure surrounding
GSM and GPRS base stations and to aid positioning of
GSM and GPRS aerial systems, in addition, it may be used
to identify sources of interference.
The supplied aerial may be removed to allow performance
testing of other aerial systems. Settings allow the
measurement and display of all available GSM and GPRS
networks. Alternatively, the Test Set can be 'locked' to one
network only.
The Test Set contains a battery allowing remote operation
for up to 12 hours. The internal battery may be recharged
from the supplied mains power supply.
21CN-MODE™
All DualCom products have a programmable 21CN-MODE™
whereby enhanced polling on the radio path will avoid
unnecessary keyholder contact from telephone or IP path
disruptions. 21CN-MODE™ can also be used to increase
polling over Holiday or high-stock periods.
DualCom GPRS G2 can also be upgraded remotely. If for
any reason your insurance specification increases there will
be no need to install a new system - just contact your ARC
to move your system from Grade 2 to Grade 3 or
downgrade if required.
DualCom GPRS G2 has been developed with 21CN in mind
to help assist with a smooth transition from the existing
PSTN or the Legacy Network over to the 21CN Network.
Many of the digital communication systems that are
currently specified to a Grade 2 standard operate by
sending alarm signals to an Alarm Receiving Centre or ARC
over your telephone line in the event of an intrusion.
Recently changes were tabled by OFCOM where some of
the telephone numbers used by the ARC could incur an
additional cost each time the system is set and unset.
By moving to DualCom's fixed rate tariffs costs are known
from the outset.
DualCom GPRS G2 operates primarily over a wireless radio
network and will therefore not incur the same telephone line
charges.
For further information, contact CSL.
CSL Dualcom Limited
Salamander Quay West
Park Lane
HAREFIELD
Middlesex
UB9 6NZ
Tel: 01895 474 474
If the Test Set is left switched on and unused, the unit will
automatically switch off after a preset time. The Test Set is
contained within a strong protective sleeve and is supplied
complete with a charger, aerial and manual.
03/12
Intruder Catalogue
Chapter 22 Page 7
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 8
Chapter 22 - Signalling
Traditional Single Path
Traditional
Single
Path
(telephone)
First signal
indicates line fault
Second signal
cannot be transmitted
NO SIGNAL PATH
DualCom GPRS G2
DualCom
GPRS
(radio &
telephone)
First signal
indicates line fault
RADIO CONFIRMED
Second signal confirms
subsequent alarm
Technical Specification
Product Codes
CS2366 Radio Test Set Technical Specifications
Dimensions: (h x w x d) 135 x 78 x33 mm (215mm high
with supplied aerial)
Weight:
210 grammes (includes aerial)
Temperature:
-20C to +60C transit, -4C to +40C
operating
Battery:
4 volt, 500mA/h Solid Electrolyte
Lithium Ion
Charger:
Nokia Type ACP-12X or alternative
Power :
Mains 50mA (operation & battery
recharging)
Aerial connector:
SMA
CS2212
Chapter 22 Page 8
CS2366
CS2056
CS2322-IRE
3RD-PARTY-W-SIM
Intruder Catalogue
CSL Dualcom Grade 2 GPRS with
world SIM…UK Only
CSL GPRS Radio Test Set
CSL 5M extension lead for Dualcom
GPRS units
CSL Dualcom grade 2 GPRS
with Vodaphone SIM - ROI Only
World roaming sim designed for use
with third party GPRS
signalling devices other than CSL
Dualcoms. CSL part CS2394 World
roaming SIM that covers, ORANGE,
VODAPHONE, O2 and TMOBILE
networks
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 9
Chapter 22 - Signalling
Features
• Lightweight
• May be used to identify sources of interference
• Remote operation for up to 12 hours
CSL Signal Test
The CS2366 is a Radio Test Set for use with GSM and
GPRS Radio Networks.
The Test Set will measure and display radio signal strength
received, plus levels of received of interference. With the
supplied aerial, it may be used to measure surrounding
GSM and GPRS base stations and to aid positioning of
GSM and GPRS aerial systems, in addition, it may be used
to identify sources of interference.
The supplied aerial may be removed to allow performance
testing of other aerial systems. Settings allow the
measurement and display of all available GSM and GPRS
networks. Alternatively, the Test Set can be 'locked' to one
network only.
If the Test Set is left switched on and unused, the unit will
automatically switch off after a preset time. The Test Set is
contained within a strong protective sleeve and is supplied
complete with a charger, aerial and manual.
For further information,
contact CSL:CSL Dualcom Limited
Salamander Quay West
Park Lane
HAREFIELD
Middlesex
UB9 6NZ
Tel: 01895 474 474
The Test Set contains a battery allowing remote operation
for up to 12 hours. The internal battery may be recharged
from the supplied mains power supply.
Technical Specification
Product Code
Dimensions:
CS2366
(h x w x d) 135 x 78 x33 mm (215mm high
with supplied aerial)
Weight:
210 grammes (includes aerial)
Temperature:
-20C to +60C transit, -4C to +40C
operating
Battery:
4 volt, 500mA/h Solid Electrolyte
Lithium Ion
Charger:
Nokia Type ACP-12X or alternative
Power :
Mains 50mA (operation & battery
recharging)
Aerial connector: SMA
03/12
Intruder Catalogue
CSL GPRS Radio Test Set
Chapter 22 Page 9
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 10
Chapter 22 - Signalling
Features
• Guaranteed to make all digital communicators NGN and
21CN compatible
• Simple to fit in less than 5 minutes and supplied ready
programmed
• No need to change/reprogram/adjust existing digital
communicator
• More robust administration structure for older digital
communicators
• Can use any telephone line from any provider
• Will not affect or be affected by other telephone equipment
DigiPlus® DualCom
DigiSolo® and DigiPlus® are essentially the same product
– the new version of DigiSolo® is able to convert and
upgrade to a DigiPlus® either from the point of purchase or
at any point in the future. Every DigiSolo® is connected to
DualCom’s Gemini managed network free of charge but is
not enabled with the features of DigiPlus® until activated.
The DigiSolo®/DigiPlus® single hardware platform was
developed in conjunction with Vodafone to fit between any
existing digital communicator and the telephone line
providing an improved and robust signalling solution. It is
guaranteed to make all existing digital communicators fully
compatible with NGNs and BT’s new 21st Century Network
(21CN) as it uses a 300 baud modem. The sole purpose of
DigiSolo® is to provide immunity for NGN/21CN round-trip
issues. In addition DigiPlus® guarantees compatibility and
provides a fixed cost solution to varying non-geographical
telephone number rates used by most UK Alarm Receiving
Centres by using 0800 free telephone calls for all alarm and
polling traffic. DigiSolo® can be upgraded to a DigiPlus®
remotely by your ARC for an additional monthly
payment – this payment can be offset by your Customers’
saving on telephone charges.
Solution
DigiSolo® and DigiPlus® provide an invaluable solution to
the issues created by the current upgrade of the UK’s
telephone network from analogue switched circuit (PSTN)
technology to digital Internet Protocol (IP) technology. The
new Networks are known as Next Generation Networks the
biggest of these being BT’s 21st Century Network. In total
BT plan to have upgraded 40% of its Network by 2012 –
that’s 10 million premises! NGNs could affect many intruder
and fire alarm systems signalling to Alarm Receiving
Centres (ARCs).
Many tens of thousands of older intruder alarm systems that
use Digital Communicators (DigiComs) will be more
seriously affected. During migration DigiComs will
experience outages of up to 30mins, during which time no
alarms will be delivered to your ARC. This may leave end
users with large telephone bills and burden installers with
outdated legacy equipment.
Product Code
CS2100
CSL DigiPlus
Digital Communicator
Vodafone Data
Network
Primary DigiPlus
Polling Server
Secondary DigiPlus
Polling Server
Telephone Line
CS2100 DigiPlus
Telephone Line
Telephone exchange
Chapter 22 Page 10
Alarm Receiving
Centre
Kilostream X25
Line
PSTN/X25
Gateway
Telephone Line
Telephone
Exchange
Intruder Catalogue
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 11
Chapter 22 - Signalling
Features
•
•
•
•
•
•
Remote upload/download
Dual path
Connects to any alarm panel
Touch screen programming
Easy to set up
EN50131 & EN50136 Grade 4
Chiron Iris Touch IP Signalling Units
The IRIS dialler range offers a quick and cost effective way
to interface any existing alarm system to alternative
networks such as GSM, Ethernet and GPRS.
The IRIS range of alarm diallers allow users to migrate
intruder alarm systems away from traditional PSTN
communications to IP based and/or wireless networks,
without the need to upgrade or replace the alarm system.
The majority of intruder alarm systems which are configured
to make alarm calls to a central monitoring station use the
traditional PSTN analogue network as the communications
path. However, PSTN is becoming increasingly unsuitable
as users move to IP and Voice over IP (VoIP) for their fixed
networks or rely purely on mobile (GSM and GPRS)
communications. In addition most PSTN service providers
are migrating to VoIP networks, so in the not too distant
future PSTN lines may be withdrawn.
Alarm dialler Interface
Two wire interface via RJ11 socket
40V feed at 12mA
Ringing voltage 40V P-P to REN4 for incoming calls
Off hook detection with dial-tone presented to alarm dialler
DTMF tone recognition for dialling outgoing calls and alarm
signaling
Ethernet Interface
10Mbps and 100Mbps (10/100BaseT) with auto-negotiation
UTP with standard RJ45 socket for CAT-5 cabling
Dynamic IP addressing (DHCP) or fixed
PIN Inputs
Maximum input voltage range
Input ‘low’ threshold
Input ‘high’ threshold
Input pull-up impedance
Relay Outputs
Maximum operating voltage
Maximum current rating
Power Supply
Supply voltage 9 - 30V DC
Ethernet only (typical current) dialler on hook
Ethernet only (typical current) dialler off hook
With GSM/GPRS (typical current) dialler on hook
With GSM/GPRS (typical current) dialler off hook
The IRIS 400 series is intended to be used with alarm panels
that that have sufficient space inside their enclosures for the
IRIS dialler to be fitted. There are two diallers in the range:
• IRIS Touch 420 - Ethernet
• IRIS Touch 440 - Ethernet & GPRS
The IRIS Touch dialler should be located within the alarm
panel tamper protected enclosure and powered from the
alarm panel or via a boxed battery backed power supply.
GSM/GPRS Interface
Dual band GSM 900 MHz and DCS 1800 MHz
MMCX socket for antenna connection
IP
TCP ports (outbound): 51292 (diagnostics), 52737 (polling),
53165 (alarms)
UDP ports for upload/download 8738 and 8739
0V to +24V
< 2V
> 3V
Internal 10K to 5V supply
24V
1A
145mA (supply at 12v)
175mA (supply ay 12V)
185mA (supply at 12V)
215mA (supply at 12V)
Note: These figures are based upon the Ethernet link being connected. With GSM/GPRS there will also be additional transient peak current of up to 250mA required as GSM and
GPRS transmissions (e.g. for network registration and calls) are made.
Weights
Dialler unit
Fully packaged
03/12
300g
500g
Intruder Catalogue
Chapter 22 Page 11
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 12
Chapter 22 - Signalling
What is IP?
Quite simply IP uses the Internet to carry security
communications instead of the old switched telephone
network. This means that vastly more information, of vastly
different kinds can be sent without the need for dedicated
lines; information such as voice, data and high definition
CCTV. It also allows that information to be two-way, so a
monitoring centre can communicate with a remote site,
interrogate its health, control cameras and even conduct
remote maintenance.
There's also considerable pressure from the
telecommunications companies themselves or the security
industry to switch to IP. Because IP uses less bandwidth
than conventional methods, it frees up capacity to be used
for other purposes such as on-demand television. Indeed,
much of the European telecom network is in the processes
of planning the withdrawal of the services that makes non-IP
security communications possible - so soon IP in security
will not be a choice, but a certainty.
Feature
Flexibility
The IRIS Touch range is able to convert virtually any existing
analogue based security installation to IP, no matter its age
or manufacturer. Similarly the receiving unit appears as a
standard unit with a serial interface to the monitoring centre
operator.
Simplicity
The IRIS Touch range has been designed to be simple to
install, configure and use. It requires no deep knowledge of
the Internet and is no more complex to set up than a home
broadband connection. This, in part, is due to a unique
touch screen that guides users and installers through every
step and makes troubleshooting simple.
Capability
IRIS Touch makes full use of all the advantages that IP
brings to security communication, from remote
troubleshooting to CCTV control, to communications
resilience. It offers dual path backup by all standard
methods, flexible polling and simpler upgrade paths.
Indeed, it allows any analogue installation to become part of
the IP revolution.
Touch 420 Ethernet Touch 440 Ethernet & GPRS
•
•
•
•
•
•
16
4
16
4
•
•
•
•
•
•
•
•
16
16
•
•
•
•
•
•
•
Easy to install and test with touch screen interface
2-wire (POTS) analogue interface to standard alarm diallers
Support for SIA (1-3), Contact ID,Scancom (Fast Format) and Robofon protocols
Pin inputs for alarm messages over SMS
Relay contact outputs
9-30V DC power from alarm panel
USB port for local configuration
Secure polling (monitoring) over Ethernet
Secure alarm transmission over Ethernet
Pin inputs for alarm messages over Ethernet or GPRS
Configuration and diagnostics over Ethernet
Secure polling (monitoring) over GPRS
Secure alarm transmission over GPRS
Configuration and diagnostics over GPRS
Alarm transmission over GSM
•
Serial port for connection to alarm panel for fast upload/download
Product Codes
IRIS-Touch-420
IRIS-Touch-440
Chapter 22 Page 12
Intruder Catalogue
Chiron IRIS Touch 420 IP Module
Chiron IRIS Touch 420 IP/GPRS
Module
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 13
Chapter 22 - Signalling
Features
• Constant signal path monitoring
• Dual path signalling
Ethernet IP with GPRS backup
• Dual path communications
• Alarm panel management over GPRS
• Configuration via USB
• Integrated panel support
Galaxy bus alarms to Ethernet
Galaxy bus alarms to GPRS
Galaxy remote management over Ethernet
Galaxy remote management over GPRS
IRIS Touch 640 - IP and GPRS
The IRIS Touch 640, IRIS Touch 640 - IP and GPRS
A cost-effective PCB based dialler offering both IP and
GPRS and intended for Installation in existing panels,
including fire.
Chiron has LPS1277 accreditation for all 9 of it’s products
and the fact that the new product, the IRIS Touch 640
optimised for working in the Galaxy panels.
The IRIS Touch 640 brings IP operation, and high
specification integration, to many legacy panels including
Honeywell and offers fast remote access, easy installation,
and commissioning.
Alarm Dialer Interface
Direct connection to various panel types:
Honeywell Galaxy (V4.00 onwards) (via RS485)
Texacom Premier (V7.60 onwards) (via serial)
RS485 2 wire half duplex
Serial data – 3V logic levels (5V tolerant), Tx, Rx, Ground
Ethernet Interface
10Mbps and 100Mbps (10/100BaseT) with auto-negotiation
UTP with standard RJ45 socket for CAT-5 cabling
Dynamic IP addressing (DHCP) or fixed
GSM/GPRS Interface
Dual band GSM 900 MHz and DCS 1800 MHz
MMCX socket for antenna connection
IP
TCP ports (outbound): 51292 (diagnostics), 52737 (polling), 53165 (alarms)
PIN Inputs
Maximum input voltage range
0V to +24V
Input ‘low’ threshold
< 2V
Input ‘high’ threshold
> 3V
Input pull-up impedance
Internal 10K to 5V supply
Relay Outputs
Maximum operating voltage
24V
Maximum current rating
1A
Power Supply
Supply voltage
9 - 30V DC
Ethernet only (typical current)
145mA (supply at 12v)
With GSM/GPRS (typical current)
185mA (supply at 12V)
Note: These figures are based upon the Ethernet link being connected. With GSM/GPRS there will also be additional
transient peak current of up to 250mA required as GSM and GPRS transmissions (e.g. for network registration and calls) are made.
Weights
Dialer unit
60g
Fully packaged
160g
Product Code
IRIS-TOUCH-640 IP Signaling unit Opt for Galaxy Panel
03/12
Intruder Catalogue
Chapter 22 Page 13
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 14
Chapter 22 - Signalling
Features
•
•
•
•
WebWay 2424 IP Signalling
WebWay 2424 is a managed alarm transmission system for
intruder, fire and imaging, polled end to end. Any
interruption of the service results in automatic notification of
both alarm panel and ARC. WebWay 2424’s technical
alarm features and polling assist in the diagnosis of faults or
network outages and generates availability reports per site
for the use of end users, insurers, installers, installers,
inspectorates and ARC’s.
WebWay 2424 goes beyond the standards, with end to end
polling identifying a three minute outage of either signalling
path, message encryption, device substitution protection an
password controlled remote engineering functions.
Exceeds the needs of EN50131 Grade 4, BS8148, CFOA
and insurance requirements.
Hardware
Product name
Alarm panel connection
Number of pin connections
Data port
Number of outputs
Event log Over
Remote upgrade
Remote diagnostics
On board configuration options
Configuration via alarm panel keypad
Dual path option?
Enclosure available?
Remote power management?
Current draw
Environmental class
Features
Standards Grading
IP/ADSL broadband service providers
Mobile service providers
SIA protocol transmission
Line failure notification on Primary Path
Line failure notification on Secondary Path
Notification of either path
failure to alarm panel
Notification on alarm panel loss
Encryption of all messages, polls, engineering
Hardware substitution protection
Message replay protection
Chapter 22 Page 14
IP Products
2424 Broadway
RS232, TTL, RS485,
modem
up to 16
RS232 (option)
3
1000 events Over
Yes
Yes
Yes
Yes, GPRS
Yes, Grade 3
Yes
190mA
II
Can be fitted in existing EN PSU’s
Uses standard communications
Network Reliability
EN Grade 4
Security Signalling over IP
Within the security signalling environment it is essential that
any signal sent over an IP network is known to have arrived
at the receiver and has been protected from being read or
replayed by a third party whilst in transmission.
The WebWay 2424 systems always know if a signal has not
been delivered to any of the multiple receivers inside the
alarm receivingcentres. If a signal is known not to have
been delivered a sophisticated retry process is instigated
automatically, trying multiple IP and GPRS routes.
Should a signal not have arrived, then there will have been
a network failure or attack. Any such event will have
resulted in the loss of the WebWay 2424 secure polling
regime, generating the required communications failure
indications at the ARC within three minutes. As the solution
is polled end to end, from premises to ARC, the WebWay
2424 Communicator intelligently understands that it is not
receiving line polling acknowledgment from our receivers
and informs the alarm panel of the failure.
GPRS-PSTN Products
2424 Airway
RS232, TTL, RS485,
modem
up to 16
RS232 (option)
3
1000 events
Yes
Yes
3 buttons or computer i/f
Yes
Yes, PSTN
Yes, Grade 3
Yes
130mA
II
PD6662, EN50131-1, EN50136 series. Default configured to
Grade 4, ATS5 for both Primary and Secondary paths
Any
Any
Vodafone, Orange, O2 or own choice
Yes
Yes
180 seconds, configurable for all solutions
180 seconds, configurable for all solutions
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Intruder Catalogue
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 15
Chapter 22 - Signalling
Product Codes
22-5005-IPUR
Webway IP/GPRS LPS I&HAS ATS5 purchased
22-5005-FPUR
Webway IP/GPRS LPS Fire Type 1 purchased
22-5014-PUR
Webway IP-Digi purchased
22-5059
Dial Capture Plug on alarm
Plug on to convert any Serial board to a Combi for connection to
panels with an integrated modem.
22-5049-10M
Extension antenna with 10M
Extension antenna with 10m cable specified at order
22-5049-15M
Extension antenna with
15M Cable
Extension antenna with 15m cable specified at order
22-5054
Smart Disc Engineers pack
Local signal improvement antenna, 0.5m cable
22-5038
Remote PINs module
Remote PINs module, RS485 bus connection to PCB, 8 PINs.
Provides additional pins, or enables pin only connection to a remote
alarm panel.
05-5022
10 meter ethernet cable
Alternative cable length requirement for special projects
05-5023
20 meter ethernet cable
Alternative cable length requirement for special projects
03/12
Intruder Catalogue
Chapter 22 Page 15
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 16
Chapter 22 - Signalling
Features
• Built-in Abort function to enable older alarm systems to
comply with the ACPO false alarm policy.
• Provides robust Fast Format which is resilient to delays
introduced by next generation networks
• Monitors the PSTN line continuously - if a fault occurs, a
message will be sent to the control panel.
• In case of a misoperation when the system is set, and the
system is unset within 90 seconds, a “Restore on Channel
3”, or separate, code will be sent to the Alarm Receiving
Centre.
• PC programmer - easily programmed with 7200/7300
• 8 alarm inputs – when Triggered by the alarm system, the
DigiCom2 initiates calls to the Alarm Receiving Centre.
• Built-in relay for serial handset connection
• Three way calling to override engaged Telephone line.
• NVM re-usable chip -Fully compatible with Scantronic NVM
chips.
Digital Communicator
The DigiCom2 is an advanced auto-dialing digital
communicator for alarm reporting. It can transmit alarm
signals to an Alarm Receiving Centre via the analogue
PSTN (Public Switched Telephone Network) using the
‘DTMF Fast Format’ protocol.
The DigiCom2 has 8 alarm inputs. When triggered by the
alarm system, it initiates calls to the Alarm Receiving Centre
(ARC).
Technical Specification
Product Codes
The DigiCom2 is housed in an ABS plastic case which
protects the electronics.
Model
D1110 Stand Alone
Dimensions
(h x w x d) 19 x 61 x 91 mm
Weight
80 grams
Telephone
Path Standard PSTN technology
Abort Facility Built-in
Power Requirement
Max 13.8v Min 9.0v DC, 0.1volt max
ripple
Current Consumption
6mA quiescent, 20mA operating
Low Battery
10.9-11.1 volts falling, 11.9-12.1v recovery
Outputs
1 Aux relay (24v 1A contacts)
Start Inputs
Max +15 volt, Min +3.5 volts DC
Temperature
-20°C to +60°C transit, -4°C to +5°0C
operating
Humidity
0 - 80% non-condensing
Chapter 22 Page 16
D1110
D1154
D1055
Intruder Catalogue
Dycon Digicom 2, 8 channel standalone
digital communicator
chip programmer with CD and USB
cable (available via NSL)
NVM chip (available via NSL)
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 17
Chapter 22 - Signalling
Features
• LCD display.
• Programmable 9 x 32 digit phone numbers for each
trigger.
• 10 second duration recordable message for each trigger.
• Built in memory for telephone numbers and programmed
setting.
• Dual Triggers.
• Programmable as Silent Alarm (dial only) or Audible (siren
+ dialler).
• Cancel Message and Alarm at remote telephone using *
Key or cancel message only using # Key.
• Programmable daily, weekly or monthly test message.
• Network Provider Field Strength Indication.
GJD Voice Dialler
When your burglar alarm goes off the reality is that in most
situations it is ignored. Many people view the alarm siren as
a nuisance and do not call the police or bother to
investigate. The GJD Voice Dialler offers a solution.
The GJD Voice Dialler is the ideal companion for virtually
any alarm control panel as it provides additional protection,
rather than relying on the outside bell to attract attention.
When the alarm is triggered, the Voice Dialler will ring a
combination of nine different numbers (including mobile
phones) to alert people you know and trust so they can
investigate appropriately.
The unit stores up to two pre-recorded messages which can
be used to warn of two different situations, e.g. burglary,
personal attack, fire etc. These are specific to your alarm
system and can be changed as often as desired.
The Voice Dialler is connected between the alarm control
panel and the telephone line. It behaves like another
extension to the telephone and does not affect the normal
operation or that of any other extensions fitted. However, if
the Voice Dialler is operating, the messages will be heard if
any hand set is lifted. it requires no batteries as its power is
derived from the alarm control panel.
The Voice Dialler is simple to operate with clear on screen
instructions guiding the user through programming
messages and telephone numbers. Recording a message is
easy as the has a built in microphone and speaker so that
phrases can be recorded and replayed directly into the unit.
When the outgoing call is answered the Voice Dialler plays a
common phrase which normally states your name and
address and one of the phrases relating to the inputs from
the control panel (PA, burglary, fire and auxiliary in our
example).
Product Code
GJDHYL004
03/12
Intruder Catalogue
GJD voice dialler
Chapter 22 Page 17
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 18
Chapter 22 - Signalling
Signalling Accessories
Return Path signal LED
Product Code
Return Path Signal LED
7113
Return path signal LED for indicating
‘system set’ return signal from Alarm
Receiving Centre
(1015-00)
BT Line Jack Lead
Product Code
BT Line Jack Lead
2118
BT line jack lead
Captive Locking Bar
Product Code
Captive Locking Bar
2119
Captive Locking Bar for BT line jack
BT Extension Line Jack
BT extension line jack for connection
of alarm panels to existing telephone
lines
Product Code
BT Extension Line jack
2117
Versus Modem Compatibility Device
MCD 46801 Interface
Product Code
608.009.171 Versus Modem
Compatibility Device
MCD
608.009.171
Chapter 22 Page 18
Intruder Catalogue
03/12
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 19
Chapter 22 - Signalling
Features
•
•
•
•
•
•
•
•
ADSL Alarm Micro Filter Z-A431UK
With the proliferation of DSL for high-speed Internet access
in residences and small businesses, alarm dealers and
service providers receive an increasing number of reports of
interference between their customers. DSL service and
alarm systems. When alarm panels have difficulty dialling
out and reporting incidents in an emergency, customer
service calls increase, customer confidence decreases and
company profits can suffer.
Tyco Safety Products are pleased to announce the launch of
a new Broadband micro filter from Focus. As the number of
installed bases of Broadband increases, so too does the
need for a professional, reliable interface between the
intruder alarm and the broadband line. Since a broadband
line incorporates the ability for both "voice channel"
communication and also "data channel" it is very easily
possible to use the voice channel for the intruder alarm
signaling whilst still keeping available the data channel for
computer use. For more complex installation, particularly
those required to meet EN 50131 the new hard-wired filter
(608.009.196) is a more necessary solution.
The (608.009.196) filter provides screw termination to the
incoming line, to the alarm panel and provides further screw
terminals to allow a "through line" carrying both the
voice and data channels to further outlets in the installation.
In addition, the filter incorporates line seizure of the "through
line" voice channel and has lightning fuses for additional
protection.
This is the only DSL filter in the world designed solely for UK
alarm systems. The current filter (608.009.221) should be
used in conjunction with the new filter and distributed
through out the subscribers premises for filtering of other
voice band equipment devices, such as dial up modems,
fax/answering machines and telephones.
03/12
Reliable alarm panel dial-out
Uninterrupted DSL/HPN communication
Over-voltage protection,
Easy installation
Compatibility with Full Rate DSL, G.Lite DSL, V.90 and
Metallic Loop Testing (MLT)
CE Mark Certification pending
Broadband Compatible
These just need to be plugged into the sockets and then
have the devices plugged into the filters.
Broadband
As DSL service becomes more commonplace and more
affordable, more customers are choosing to use high speed
internet and compatibility issues are arising. Worryingly,
compatibility issues often occur without the knowledge of:
The alarm installer
The insurer
The customer
Z-A431EU
The Z-A431EU offers service providers an effective way to
block interference between DSL and monitored alarm
panels. It is the only DSL filter in the world designed solely
for European alarm systems. The Z-A431EU isolates high
frequency DSL and HPN (Home Phone Network) signals
from low-frequency voice and data communication.
Installation
The Z-A431EU can be installed in an alarm system at any
time. It can be used on an existing installation when DSL is
activated. It can be installed on a new installation when DSL
is active or before DSL is active.
Retrospective Installations
The Z-A431EU can obviously be installed into existing
systems as and when the customer chooses to have DSL
activated. When DSL is activated, customers are generally
aware of the necessity of standard filters. However, alarm
panels are frequently neglected and the system is left in a
simple installation (no line seizure).
In order for a monitored alarm to work effectively on a
broadband line, the Z-A431EU must be installed in front of
the alarm panel where it can filter the DSL signals.
Intruder Catalogue
Chapter 22 Page 19
Intruder_Ch22_Signalling:Layout 1 20/03/2012 10:42 Page 20
Chapter 22 - Signalling
New Installations
All new alarm installations must meet EN50131. To do this,
the alarm panel must be capable of line seizure. In order
to achieve this, the alarm must be installed first in line in
the system. The ZA431EU allows alarm panels to meet
EN50131. It is simply inserted between the telephone
master socket and the alarm panel, allowing line seizure
to continue, but also filtering the DSL signal from the
alarm panel.
Alarm dealers and service providers have taken various
approaches to solve this problem, such as:
•
•
Installing a splitter or separate phone line,
which is more costly than an Alarm Filter
Installing a standard DSL filter at the alarm
panel, which prevents the alarm panel from
seizing a dial-out line if there is an emergency,
or if the line is cut. In addition, a standard DSL
filter will not ensure the highest possible data
rates and does not filter all high-frequency
disturbances such as those from a cordless
phone.
None of these approaches provide a low-cost, reliable
solution to the problems created by the co-existence of
DSL service with an alarm system.
Introducing Z-BLOCKER® Alarm Panel DSL Filter
The Z-BLOCKER Z-A431UK provides alarm dealers and
service providers with a low-cost alarm panel DSL filter
that keeps customer service calls down and customer
satisfaction up.
The only DSL filter in the world designed solely for UK
alarm systems, the ZA431UK isolates high-frequency DSL
and HPN (Home Phone Network) signals from
low-frequency voice and data communication to provide:
•
•
•
•
•
•
•
Reliable alarm panel dial-out in case of
emergency or cut line, even during
high frequency disturbances not related to DSL
Uninterrupted DSL/HPN communication during
alarm panel line seizure and incident reporting
Screw down terminal connections for line seizure
and cut-line protection in alarm panels, freeing
phone line to report incidents
Over-voltage protection, protecting alarm panel
from power surges and reducing service calls
Easy installation for service provider personnel
less than 15 minutes to insert filter between alarm
panel and phone line and perform a system test
Compatibility with Full Rate DSL, G.Lite DSL, V.90
and Metallic Loop Testing (MLT)
CE Mark Certification pending
The Z-BLOCKER Z-A431UK can be used in conjunction
with other Z-BLOCKER DSL filters such as the BT SINcompliant model Z-420UK-A. These filters are distributed
throughout the subscriber’s premises for filtering of other
voice band equipment devices including wired/cordless
telephones, fax/answering machines, dial-up modems,
and automatic diallers.
Product Codes
608.009.196
608.009.222
Main Filter
Plug in Filter
Wiring Diagram
Filtered DSL (analogue only) Line
Pass Through 1
A Line To A 1
B IN Equip B 1
Digicom
Master Socket
DSL (digital and
Analogue) Line
A Line From A 1
B OUT Equip B 1
Pass Through 2
Alarm Panel
Z-A431EU Filter
To phone
Extension 1
To computer
Extension 2
Chapter 22 Page 20
Standard
DSL Filters
Intruder Catalogue
03/12
Intruder_Ch23_Sounders:Layout 1 20/03/2012 10:43 Page 1
Chapter 23 - Sounders
Sounders
In many cases, the use of an external siren is beneficial to draw attention to the property where the alarm has been
generated. In addition, the noise from an external siren may cause a would be intruder to flee.
External Sounders
Features
•
•
•
•
•
•
•
•
•
•
•
•
Standard ADT Outdoor Sounder
Elmdene’s Advanced Sounder Module combines high
specification with low cost and also an enhanced sound
output at only 100 mA load. Elmdene are pioneering new
methods (patent applied for) of piezo drive to maximise
sound output levels without drawing excessive power from
the control panel.
Low Current 100mA, Remote Test Facility
High Output Siren 108dB(A)
Engineer Input for quiet installation
High Security Electronic Module Cover
Microprocessor Controlled, Internal Power LED
Active in-rush current limit on strobe with power save after
15 minutes
Active fault monitoring with healthy output
Sounder Time-Out of 15 minutes
Easy installation audible verification of tamper status
2-way tamper-wall and cover
Conformal coated boar and SAB operation
PD6662:2004 and EN50131 ready
Additionally, the unit will assist the installer with
commissioning with Elmdene’s unique commissioning
mode including silent start up and audible tamper and
battery connection verification. A fully enclosed and
conformal coated PCB prevents the weather from affecting
normal operation.
Using the latest microprocessor technology, Elmdene have
completely updated the 7422 siren to keep up with the latest
intruder alarm standards. Product enhancements include
piezo and battery monitoring (both load tests and voltage
checking) and the ability to do remote testing without the
need for a site visit. Any faults will be signalled back to the
panel within seconds.
Product Codes
Technical Specification
Environmental
Sounder Volume:
Cut off TImer:
Waterproofing:
Operating Temp:
Storage Temp:
Electrical
Supply Voltage:
Current:
Sounder:
Strobe:
Battery:
Type:
Voltage:
Capacity:
Strobe Rating:
Strobe Flash Rate:
Tamper Return:
Healthy Output:
Physical
Material:
Tamper Detection:
Kinetic Protection:
03/12
108dB(A)
15 minutes max
All electronics conformal coated
-25 to + 55°C
-25 to + 70°C
7423
7422-EN
676.002.055
TYCO-LED-MODULE
LBP001
9-15Vd.c. (13.8Vd.c. nominal)
17mA quiescent
100mA Sounder
100mA
SIREN-BACK-PLATE
Ni-MH
6.0V
320mAH
1 Watt
1 Hz reduces to 1/2 Hz after 15min
Volt Free - 16 nominal resistance
Open Collector Referenced to H-
ADT Hexagonal Siren Cover
Outdoor Siren for Hexagonal
Siren Cover
Plastic Bracket for Hexagonal
Siren Cover
2 x LED Module for Dummy +
External Sirens
Battery pack for LED module
when using Dummy sirens
Aluminium mounting plate for
external siren. The mounting
plate is made from 3mm
Aluminium and measures
350mm x 350mm
1,2mm Galvanised Steel
Cover and Rear/module
IK07
Intruder Catalogue
Chapter 23 Page 1
Intruder_Ch23_Sounders:Layout 1 20/03/2012 10:43 Page 2
Chapter 23 - Sounders
Features
•
•
•
•
•
•
•
•
•
Rapier 6000
Stainless Steel Cover
Dual Steel Skin Enclosure
Twin Streamlines Translucent Strobes
Dual Piezo Sounders
Twin Comfort LEDs
Electronics Fully Enclosed
Full SAB facility with on-board 12V Nicad Battery
Engineer Mode for Silent Start-Up
Universal Trigger and Tamper
Superior quality metal External Sounder which is ideal for
prestigious installations and projects. It meets requirements
for High Security installations (BS 7042).
The Rapier 600 is vandalism protected and internally
protected for long life in harsh environments. ‘Engineer
Friendly’ for easy installation and maintenance.
Technical Specification
Product Codes
Dimensions:
Materials:
Cover:
Backplate:
Steel Protective:
Treatment:
340mm x 220mm x 55mm
Plated Painted or Stainless Steel
(1.2mm)
Plated Steel (1.2mm)
7632
SIREN-BACK-PLATE
Zinc Plated and Coloured
Passivated
Siren:
Input Voltage:
Operating Voltage:
Current:
Sound Output:
12V dc Nominal
13.8V Nominal
350mA Nominal
118dB at 1m
Strobe:
Input Voltage:
Flash Rate:
Current:
Full Slab:
12V dc Nominal
1 per second
150mA Nominal
12V NiCad Battery
Chapter 23 Page 2
7631
7407
Intruder Catalogue
Rapier 6000 Stainless Siren
Rapier Stainless Steel High
Security Siren (Grade 4)
Rapier Stainless Dummy Siren
when using Dummy sirens
Aluminium mounting plate for
external siren. The mounting
plate is made from 3mm
Aluminium and measures
350mm x 350mm
03/12
Intruder_Ch23_Sounders:Layout 1 20/03/2012 10:43 Page 3
Chapter 23 - Sounders
Features
• High Output
• Mains Powered
• IP67 Rated
High Output Sounders Klaxon Duplo High Output Siren
Klaxon Duplo High Power Siren
The Duplo is a powerful weatherproof motor driven siren
producing a clear, distinctive note suitable for use in fire,
security and general industrial use.
Secomac Master Blaster External Siren
Master Blaster is the most powerful security siren of its type
available. Mains powered but triggered by a 12V relay.
It has a sound output of 127dB at 1 metre. The unit has a
weatherproof ABS body and comes pre-wired with 1m
cable.
Technical Specification
Product Codes
Klaxon Duplo High Power Siren
Voltage:
12Vdc - 15.0A
24Vdc - 8.3A
110Vac - 2.0A
230Vac - 1.0A
Audibility:
126dB at 1 metre
Frequency:
1500Hz
Rating:
On 15 mins, off 10 mins
Weight:
2.04Kg
Case Material:
Aluminium Alloy LM25
Colour:
Grey/Black
7068
7622
6143
Klaxon duplo high power siren
Secomac master blaster siren, 240V a.c.
Universal 240V siren relay/timer
Secomac Master Blaster External Siren
Weight:
1.8Kg
Voltage:
110Vac, 2.7A
Audibility:
127dB at 1 metre
Frequency:
1680Hz
Rating:
Continuous
Colour:
Yellow
03/12
Intruder Catalogue
Chapter 23 Page 3
Intruder_Ch23_Sounders:Layout 1 20/03/2012 10:43 Page 4
Chapter 23 - Sounders
Internal Sirens
Internal sirens operate both as an early deterrent to intruders and as a method of indicating changes in system status
to property occupants.
Internal
Extension Speaker
Extension speaker for connection to
the horn output of the Galaxy range
and most Scantronic control panels.
As this unit is a speaker, when
connected to the correct alarm panel,
different tones will be generated to
indicate various conditions.
Product Codes
7337E
Elmdene 16-Ohm extension speaker
with 1k resistor fitted
7587E
Elmdene 16-Ohm extension speaker
with 1K resistor fitted and tamper
switch
Besson Bandit
Besson bandit 12V Piezo siren. 108db
@ 1 metre
Product Code
7067
Besson Bandit
This unit is an internal unit giving
audible and visual indication when
activated. The unit is particularly
useful for use in conjunction with an
Exitguard unit.
Product Code
676.002.033
Piezostrobe
Similar to the Piezostrobe but without
the visual element. 102dB output.
Product Code
676.002.034
Soundguard
Piezo Strobe
Soundguard
Elmdene Self Actuating Siren
Product Code
676.002.061
Elmdene INT401S Internal Self
Actuating Siren for use with
Residential Systems.
Elmdene Self
Actuating Siren
Elmdene ELM300
Product Code
676.002.054
Elmdene ELM300 Internal Self
Actuating Siren Steel Box
Elmdene ELM300 Internal Self
Actuating Siren Steel box The unit
has full SCB facility with 12 Volt
Nicads on board, cut-off timer, twin
piezo an draws 50 mA when in alarm
condition 100dB at 1 Mtr
Chapter 23 Page 4
Intruder Catalogue
03/12
Intruder_Ch23_Sounders:Layout 1 20/03/2012 10:43 Page 5
Chapter 23 - Sounders
Buzzer
Buzzer, approx. 90dB, fitted into a low
profile 8 way junction box. Approx.
25mA. Low profile bleep 2 x 2.
Product Code
7224
Buzzer
Product Code
7502
Aritech AI673
Aritech Audio/visual Optical Acoustic Indicator
Aritech AI673 Audio/visual
optical-acoustic indicator with an
additional sounder built-in on the
PCB providing the dual, visible and
audible.
AS270 Internal Siren
Product Code
7637
AS270 Internal siren. Aesthetically
pleasing unit to provide an audible
alarm in the event of alarm activation.
03/12
Intruder Catalogue
AS270 Internal
Siren
Chapter 23 Page 5
Intruder_Ch23_Sounders:Layout 1 20/03/2012 10:43 Page 6
Chapter 23 - Sounders
This page is left intentionally blank
Chapter 23 Page 6
Intruder Catalogue
03/12
Intruder_Ch24_Cable:Layout 1 20/03/2012 10:45 Page 1
Chapter 24 - Cable
Cable
Product Codes
Description
355004-WHT-100
355006-WHT-100
355012-WHT-100
355006-BRN-100
355008-BRN-100
355012-BRN-100
355008LSF-WHT100
320018-WHT-100
428723-WHT-100
428723-WHT-500
355106LSF-WHT100
355108LSF-WHT100
520003-WHT-100
355001-WHT-250
355020-WHT-100
355030-WHT-100
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
Webro
03/12
4c Security White PVC
6c Security White PVC
12c Security White PVC
6c Security Brown PVC
8c Security Brown PVC
12c Security Brown PVC
8c Security LSF White 100m
3183Y 1.0mm mains flex White
8723 EQ White LSF
8723 EQ White LSF
6c Security Screened White LSF
8c Security Screened White LSF
3pr CW1308 PVC White
Hard Drawn Lacing Wire
20c Security White PVC
30c Security White PVC
100m
100m
100m
100m
100m
100m
100m
100m
100m
500m
100m
100m
100m
250m
100m
100m
Intruder Catalogue
Chapter 24 Page 1
Intruder_Ch24_Cable:Layout 1 20/03/2012 10:45 Page 2
Chapter 24 - Cable
This page is left intentionally blank.
Chapter 24 Page 2
Intruder Catalogue
03/12
New_Intruder_Covers 3:Layout 1 23/08/2010 13:17 Page 16
Tyco International EMEA Pre-Sales & Post-Sales Technical Support
Toll Free: 00 800 CALLTYCO or (00 800-2255 8926)
Direct: +31 475 352 722
Fax: +31 475 352 725
Hours: 8am to 6pm CET
Technical Post-Sales Inquiries: [email protected]
European Distribution Centre - Echt, Holland:
(Warehousing/Distribution/
Purchasing/Customer Service/
Call Centre Helpdesk)
Voltaweg 20
6101 XK
Echt
Holland
Tel: +31 475 371 666
Fax: +31 475 371 660
E-mail: [email protected]
Technical Pre-Sales Inquiries: [email protected]
Technical Training Inquiries: [email protected]
www.tycoemea.com
Local Direct Dial Numbers:
• UK – (08081 013 753) and (08701 238 787)
Please note that in the UK, some ADT Office switchboards will not allow you to call the 08081
number. If this is the case, please use the 08701 UK number.
For more detailed product information, please visit us at www.tycoemea.com
Head Office: ADT Fire and Security plc, Security House, The Summit, Hanworth Road, Sunbury-on-Thames,
Middlesex TW16 5DB.
ADT and the ADT logo are registered trademarks of ADT Services AG and are used under license.
ADT reserves the right to modify or withdraw any product or service without notice.
World leader in fire and security solutions
PMC004B Iss. 13.8/ 03.12
© 2012 Tyco International
UK Distribution Centre
(Warehousing/Distribution/Purchasing)
Dunhams Lane
Letchworth
Hertfordshire
SG6 1BE
United Kingdom
Tel: +44 (0) 1462 667 700
Fax: +44 (0) 1462 667 777
E-mail: [email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement