Ethernet Switch

ESUL8P-PC2

User Manual

Ethernet Switch User Manual

TABLE OF CONTENTS

1 OVERVIEW ................................................................................. 3

1.1

I NTRODUCTION ............................................................................................ 3

1.1.1

ESUL8P-PC2 ....................................................................................... 3

1.2

T ECHNICAL S PECIFICATION .............................................................................. 4

2 INSTALLATION ............................................................................. 5

2.1

P ACKAGE C ONTENTS ...................................................................................... 5

2.2

C ONFIGURATIONS ......................................................................................... 5

2.2.1

Physical Connections ........................................................................... 6

2.3

I NSTALLATION M ETHOD ................................................................................... 7

2.3.1

DIN Rail Mount ................................................................................... 7

2.3.2

Wall-mount ........................................................................................ 7

2.4

E THERNET RJ45 C ONNECTIONS ......................................................................... 7

2.5

C OMBO PORTS ............................................................................................. 8

2.6

P OWER C ONNECTIONS .................................................................................... 8

2.7

F AULT A LARM C ONTACT ................................................................................... 9

2.8

LED S TATUS ............................................................................................. 10

3 TROUBLESHOOTING .................................................................... 11

3.1

S ELF TESTING ........................................................................................... 11

4 SYSTEM EXAMPLE ....................................................................... 12

5 DIMENSIONS (MM) ....................................................................... 12

6 WARRANTY .............................................................................. 13

6.1

W ARRANTY I NFORMATION .............................................................................. 13

6.2

C LASS A ITE ............................................................................................ 14

6.3

FCC ....................................................................................................... 14

7 INSTRUCTION OF DISASSEMBLY ...................................................... 14

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 2 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

1 Overview

1.1 Introduction

This manual covers the ESUL8P-PC2 series. KBC Networks’ ESUL8P-PC2 products are high performance, unmanaged, ten port industrial PoE Ethernet switches designed for use in a wide range of operating temperatures in nonenvironmentally conditioned, industrial applications. The units have redundant power supply terminals and an alarm output. All copper ports are automatically configured and the plug-and-play design provides ease and speed of installation.

1.1.1 ESUL8P-PC2

The ESUL8P-PC2 provides connectivity for up to eight, 10/100 RJ45 twisted pair copper ports which are capable of simultaneously supplying IEEE802.3af PoE and two gigabit combo ports. Each of the eight, 10/100 RJ45 ports supports a self-adaptive function allowing it to be configured to 10Base-T or 100Base-TX, full or half duplex operation mode. The two combo ports offer a 10/100/1000

RJ45 interface or a 100/1000 SFP module slot. It is available as either DIN rail or wall-mount configurations.

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 3 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

1.2 Technical Specification

Switching

Mode

Switching rate

Backplane switching bandwidth

Mac address table

Ports

Combo

Physical port

RJ45 port

Copper

Physical port

RJ45 port

Standard

Transmission distance

PoE

Physical port

Standard

Power supplied (per port)

Electromagnetic compatibility

Interference

Immunity

Power

Input voltage

Power consumption

Power supply

Environmental

Operating temperature

Storage temperature

Relative humidity

Mean Time Between Failure

Mechanical

Dimensions (W x H x D)

Protection class rating

Weight

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 4 of 15

ESUL8P-PC2

Store-and-forward

14,881pps, 148,810pps or 1,488,100pps

5.6Gbps

8k

2 x shielded RJ45, 2 x 100/1000 SFP

10BASE-T/100BASE-TX/1000BASE-T

8 x shielded RJ45

10BASE-T/100Base-TX

Auto-negotiation

IEEE 802.3

<100m

8 x shielded RJ45

IEEE 802.3af

15.4W @ +48Vdc

EN55022 Class A

IEC61000-6-2

48Vdc

16.8W (no PoE)

123W ( full load PoE)

Supplied separately

-40°C - +74°C / -40°F - +165°F

-40°C - +74°C / -40°F - +165°F

5% - 95%, Non-condensing

>300,000 hours

72mm x 152mm x 105mm

2.83” x 5.98” x 4.13”

IP30

907g

2.0lb www.kbcnetworks.com

Ethernet Switch User Manual

2 Installation

2.1 Package Contents

 Ethernet switch fitted with DIN rail mount.

 2 x Wall-mount brackets with screws

 Pluggable terminal block

 Quick Start Guide

Note: A 48Vdc PSU is required but supplied separately.

Please contact you dealer or distributor if a part is missing or damaged.

2.2 Configurations

Products are available in either DIN rail or wall-mount packages, with the following configurations:

Product Type

ESUL8P-PC2

DIN Rail

Wall-mount

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 5 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

2.2.1 Physical Connections

Top View

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 6 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

2.3

Installation Method

2.3.1 DIN Rail Mount

 Remove all packaging material.

 Attach the device to a DIN rail.

 Attach copper cables as required.

 Insert the male power block (attached to the supplied in-line PSU) to the female power socket on the device and tighten the terminal locking screws using a flathead screw driver.

See Section 2.7 for LED status.

2.3.2 Wall-mount

 Remove all packaging material.

 Unscrew the DIN rail mounting plate from the switch taking special care to retain the 3 screws using a Phillips No.1 or No.2 screwdriver.

 Attach the supplied wall mount plates to the switch using the screws that have just been removed from the DIN rail mounting plate with a Phillips

No.1 or No.2 screwdriver.

 Position the unit on the required, flat surface and secure with screws via the mounting plate holes. Screws are not provided.

 Attach copper cables as required.

 Insert the male power block (attached to the supplied in-line PSU) to the female power socket on the device and tighten the terminal locking screws using a flathead screw driver.

See Section 2.7 for LED status.

2.4 Ethernet RJ45 Connections

Each of the eight fixed RJ45 ports (P1 to P8) are adaptive and support auto MDI/MDI-X connection. They can be connected by straight through or cross-over cables to terminal devices, servers, hubs or other switches. Each switch supports IEEE802.3x so the optimum transmission mode (either half-duplex or full-duplex) and data rate (either

10Mbps or 100Mbps) will be selected automatically.

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 7 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

2.5 Combo ports

The SFP ports can be configured as 100BASE-FX/BX or 1000BASE-SX/LX/BX/ZX in any permutation.

The RJ45 ports are IEEE802.3ab compliant, 10/100/1000.

Note: If the SFP port is being used then the corresponding RJ45 port is automatically disabled and vice versa.

2.6 Power Connections

A 6 pin, power terminal block should be used to connect the power cable to the unit.

1 2 3 4 5 6

VV+ VV+

Figure 2.1 Power connections

Contact number

1

2

3

Connections

PWR2: -

PWR2: +

Fault alarm contact

4

5

6

Fault alarm contact

PWR1: -

PWR1: +

Note: If only using one power source, connect pin 1 to pin 5 and pin 2 to pin 6 otherwise the Power Fault Alarm will be lit.

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 8 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

2.7 Fault Alarm Contacts

The fault alarm contacts are in the middle of the 6 pin, screw block terminal on pins 3 &

4. An open circuit will occur if a power failure is detected.

1 2 3 4

P-Fail

5 6

24Vdc, 1A resistance

Load

External power

Figure 2.2 Fault Alarm Contacts

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 9 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

2.8 LED Status

LED

PWR1

PWR2

P-Fail

PoE 1-8

Status

ON

OFF

ON

OFF

ON

OFF

Description

Power is supplied to the unit

No power to the unit

Power is supplied to the unit

No power to the unit

Power to PWR1 or PWR2 has failed

Power is functioning to both or none of the power inputs

ON The port is supplying power to the powered device

OFF

There is no powered device attached or the power to the device has failed

Ethernet RJ45 Ports P1 - P8 Status LED

Each RJ45 Ethernet port has two indicators, a yellow lamp and a green lamp. The yellow lamp indicates port speed, and the green lamp indicates port link state.

ON Full duplex link

10/100

(Yellow)

FLASH Collisions are occurring

LINK/ACT

(Green)

OFF

ON

FLASH

OFF

Half duplex link or no connection

Effective network connection has been established for the port

Data traffic is passing through the port

No effective network connection has been established for the port

Ethernet RJ45 Ports P9 & P10 Status LED

Each RJ45 Ethernet port has two green indicators, an upper and lower. The upper one indicates the state of the port link and the lower one indicates port link speed.

Lower

LED

ON

OFF

Port operating at 1000M

Upper

LED

ON

FLASH

Port not operating at 1000M or no connection

Effective network connection has been established for the port

Data traffic is passing through the port

OFF

ON

No effective network connection has been established for the port

SFP port link established

Link

/Active

FLASH Active data flow

OFF No connection to the network

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 10 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

3 Troubleshooting

3.1 Self-testing

When the device is powered on, all LEDs on the front panel will flash twice, indicating that the ports are running normally and the Power (PWR1/2) indicator lights will be illuminated if power is connected to the respective input.

If problems are encountered when using this Ethernet switch please check the following:

 Verify that the correct power supply unit is being used; this unit requires a

48Vdc supply.

 Ensure that the correct cables are being used to construct your network: o Unshielded Twisted Pair or Shielded Twisted Pair for RJ45 connections o 100Ω Cat 3 cable or above for 10Mbps connections o 100Ω Cat 5 cable or above for 100Mbps connections o 100Ω Cat 5e cable or above for 1000Mbps connections o Twisted pair connection must not exceed 100m (328 feet)

 See section 2.7 for LED status indicators.

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 11 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

4 System Example

5 Dimensions

Figure 4.1 ESUL8P-PC2 Typical System Application

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 12 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

6 Warranty

6.1 Warranty Information

KBC extends the following LIMITED WARRANTY to the original owner/purchaser of this product as follows:

-

Five years from the date of initial sale for Ethernet switches.

-

Two years from the date of initial sale for all wireless and other network products.

-

Five years from the date of initial sale for all fiber products.

1) If, within the specified warranty period, this product, or any part or portion thereof, shall prove upon examination by KBC, to be defective in material or workmanship,

KBC will repair or replace such part or portion at KBC’s option. The warranty period on the repaired or replaced part or portion of this product shall be limited to the unexpired term of the original warranty. The buyer shall be responsible for all shipping and transportation of the product to KBC for any performance under this warranty.

2) Conditions and Exceptions: a) Any accident to this product, any misuse or abuse, alternation, use in modified form, or any attempt to repair this product shall void this warranty. These conditions to the warranty include, but are not limited to, incorrect power connections, physical damage due to mechanical shock, exposure to moisture, and circuit modification. b) SHOULD THIS PRODUCT PROVE DEFECTIVE FOLLOWING PURCHASE, THE BUYER,

NOT THE MANUFACTURER, DISTRIBUTOR, OR RETAILER, ASSUMES THE ENTIRE

COST OF ALL SERVICING OR REPAIR, EXCEPT AS OTHERWISE PROVIDED BY THE

TERMS OF THIS WARRANTY. c) FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY ON THIS PRODUCT, THE

BUYER IS LIMITED TO THE FOLLOWING DAMAGES. (1) THE COST OF LABOR TO

REPAIR OR REPLACE DEFECTIVE PARTS OR PORTIONS OF THIS PRODUCT, AND

(2) THE COST OF THE REPAIRED OR REPLACE PARTS OR PORTIONS OF THIS

PRODUCT. d) NO OTHER EXPRESSED OR IMPLIED WARRANTIES HAVE BEEN MADE OR WILL BE

MADE ON BEHALF OF KBC WITH RESPECT TO THE SALE, REPAIR, INSTALLATION,

OPERATION, OR REPLACEMENT OF THIS PRODUCT. KBC DISCLAIMS ANY

IMPLIED WARRANTY OF MERCHANTABILITY OF THIS PRODUCT OR ITS FITNESS

FOR ANY PURPOSE, AND THE BUYER AGREES THAT THIS PRODUCT IS SOLD “AS

IS” AND THAT THE ENTIRE RISK OF QUALITY AND PERFORMANCE OF THIS

PRODUCT IS WITH THE BUYER, EXCEPT AS OTHERWISE PROVIDED BY THE

TERMS OF THIS WARRANTY. e) Some states/jurisdictions do not allow exclusions or limitations of incidental or consequential damages, or limitations on how long an implied warranty lasts, so the above exclusions or limitations may not apply to you. f) If you do not wish to be bound by any of the provisions in this warranty, please return the product(s) immediately.

3) Contact your dealer regarding return authorizations for out of warranty repairs and any further product information.

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 13 of 15 www.kbcnetworks.com

Ethernet Switch User Manual

6.2 Class A ITE

This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.

6.3 FCC

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful Interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at this own expense.

7 Instruction of Disassembly

Instruction of Disassembly of KBC Product

(For EU Directive 2002/95/EEC-WEEE)

Tools required:

 No. 1 Phillips screwdriver

 No. 2 Phillips screwdriver

Steps for disassembly:

1. Remove tightening screws of box cover (8 screws).

2. Remove cover plate.

3. Remove tightening screws for printed circuit board (PCB).

4. Take out all PCBs.

Notice: When a product reaches the end of its life – return to KBC.

Manual-ESUL8P-PC2_Series_HW-Rev1201

Copyright © KBC Networks Ltd. Page 14 of 15 www.kbcnetworks.com

data delivered

KBC Networks

25691 Atlantic Ocean Drive

Suite 3B

Lake Forest, CA 92630

U.S.A

Americas

Phone:

Fax:

1-949-297-4930

1-949-297-4933

KBC Networks Ltd., EMEA

KBC Networks Ltd.

Barham Court

Teston, Maidstone

Kent, ME18 5BZ

United Kingdom

Phone:

Fax:

Email:

Web:

+44(0)1622 618787

+44(0)20 7100 8147 [email protected]

www.kbcnetworks.com

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement