AC/DC - Voltimum
2017 | 2018
Product Catalog
Electrical
Test Equipment
English
Table of Contents
About us - More than 40 years Beha-Amprobe
New products
6
Electric testing equipment
8
Voltage detectors
4
9
Lamp testers
11
Continuity testers/battery testers
13
Phase sequence indicator
14
Measuring solar radiation
15
Locating and measuring wires/cables
16
Cable locators
17
Digital multimeters
24
Current clamps
33
Measurement and test equipment in accordance with EN 61557
48
Things to know about device testing
49
Overview of national regulations
52
Measurement and test equipment in accordance with national standards
54
Accessories
66
Software packages
63
Environmental/HVAC testing
Temperature, Light, Sound, Humidity, Rotational Speed
66
Temperature meters
67
Power and Energy Measurement
79
Accessories
81
Accessories
82
Cases
88
Fuses
89
Appendix
91
Measurement categories
92
Index according to order no.
93
Index according to type description
95
3
NG 309
V1X Mini
First Voltage
Continuity Tester
Megohmeter
First Multifunction Installation tester
Unitest V1X
0100-Multitester
(first multifunction
installation tester)
Unitest 380
1975
1980
More than 40 years of Beha-Amprobe:
milestones of the brand
1985
1990
Nearly 70 years ago, in 1948, the very first inductive clamp
meter named “Amprobe” was invented in the United States
by Pyramid Instrument Company. Soon after, the Amprobe
name became so synonymous in the US with clamp meters
that in 1960 the company name was formally changed to
Amprobe Instrument Corporation.
Fourteen years later in Glottertal, Germany, Christian Beha
invented the V1X, a continuity tester designed to replace
his previous model after it failed on the job. An immediate
success, the V1X ushered in a period of rapid growth for the
company. By the mid-90s, Beha was a respected name in the
electrical industry.
Recognizing the strength and quality of each brand,
Danaher Corporation bought Beha and Amprobe in 2003
and 2006 respectively. Today, our combined legacies span
over 100 years of bringing safety, speed and ease to the
HVAC and electric professional with high-quality test and
measurement tools.
From multimeters to voltage detectors, we are always
improving on our designs to provide you with the very best
quality in tools and support.
4
1995
Hexagon 50
AT-7000-EUR Series
GT-800
Machine Tester 0113
AMP-25-EUR Mini Clamp
Unitest Machine Tester 204
VP700
Telaris ProInstall 100
2000 Beta
2000
2005
2010
2012
2015
Innovative Testing Tools for Electricians
Our products are sold by a global network of trusted
partners with a professional support team at your service,
making Beha-Amprobe the natural choice. Whether you
need test and measurement tools for industrial, commercial
or residential applications, Beha-Amprobe offers innovative
test equipment to fit your needs.
Every tool undergoes rigorous testing in our lab and by
certified third-parties to ensure the rugged durability,
quality and safety you’ve come to expect from us.
5
New products
Our new products and
recommendations
2100-Gamma
Voltage and continuity tester
with phase sequence indication,
resistance measurement and NCV
CAT III 1000 / CAT IV 600,
6 - 1000 V AC, 6 - 1200 V DC
More information can be found on page 11
BAT-250-EUR
2100-GAMMA
Battery analyzer
Article no. 4709243
More information can be found on page 13
BAT-250-EUR
Article no. 4620297
AMP-25-EUR
AC/DC TRMS
mini clamp
More information can be found on page 38
AMP-25-EUR
Article no. 4588268
Pocket-sized
14.7 cm height
AT-7000-EUR series
Multi-function cable locator
Wire tracing reinvented
More information can be found on page 20
AT-7020-EUR
Article no. 4542794
AT-7030-EUR (illustrated here)
Article no. 4542782
AMP-200-EUR series
Clamp meters
True-RMS clamp meters
An alternative to our
previous products:
ACD-14 TRMS-PLUS,
ACD-10 TRMS-PLUS
ACDC-100 TRMS
ACDC-400
More information can be found on page 38
AMP-210-EUR
Article no. 4560581
AMP-220-EUR (illustrated here)
Article no. 4560590
6
AMP-300-EUR series
Clamp meters
TRMS clamp meters
for motor maintenance
An alternative to our
previous products:
ACD-14 TRMS-PLUS
ACD-10 TRMS-PLUS
ACDC-100 TRMS
ACDC-400
More information can be found on page 39
AMP-310-EUR
AMP-330-EUR
Article no. 4560603
(illustrated here)
AMP-320-EUR
Article no. 4560626
Article no. 4560615
New products
AM-500-EUR series
Digital multimeter
ACD-14-PRO-EUR
An alternative to our
previous products:
Current clamp
with dual display (AC)
5XP-A
30XR-A
34XR-A
37XR-A
An alternative to our
previous products:
ACD-14 Plus
ACD-14 TRMS-PLUS
33XR-A
35XP-A
38XR-A
More information can be found on page 27
More information can be found on page 40
AM-550-EUR
ACD-14-PRO-EUR
Article no. 4718989
PRM-5-EUR
AM-500-EUR
AM-520-EUR
AM-540-EUR
Article no. 4102332
Article no. 4131281
Article no. 4131308
AM-510-EUR
AM-530-EUR
AM-550-EUR
Article no. 4102344
Article no. 4131296
Article no. 4131313
PRM-6-EUR
Phase sequence indicator
Motor and
Phase Rotation Indicators
An alternative to our
previous products:
An alternative to our
previous products:
DR 100
DR 705
More information can be found on page 14
More information can be found on page 14
PRM-5-EUR
Article no. 4375961
PRM-6-EUR
Article no. 4633222
Light adapters
ProInstall-75-UK
4854835 ADPTR-KIT1-EUR Light Check Adapter Kit EUR w/carrying case
Multifunction Installation Tester (for UK)
4854847 ADPTR-E27-EUR Light Check Adapter E27
4854858 ADPTR-B22-EUR Light Check Adapter B22
ProInstall-75-UK
4854864 ADPTR-E14-EUR Light Check Adapter E14
Article no. 4826466
4854873 ADPTR-B15-EUR Light Check Adapter B15
4854886 ADPTR-GU10-EUR Light Check Adapter GU10
ADPTR-GU10-EUR
ADPTR-PE-EUR
Socket testers
4854820 ADPTR-SCT-UK Socket Check Adapter UK
4854899 ADPTR-SCT-EUR Socket Check Adapter Schuko
4854900 ADPTR-PE-EUR Socket Check Adapter Schuko PE
7
Electric testing equipment
Our range of electric testing equipment
covers standard equipment for any electrician,
including the latest voltage detectors, noncontact voltage testers in a compact pen design,
continuity phase rotation indicators for safely
establishing the phase sequence, and motor
rotation direction.
Products
Voltage detectors / testers
Lamp testers
Continuity testers
Phase rotation indicators
Symbols used in this chapter
Rx
1
0
RCD / FI
Continuity test (optical and/or acoustic)
Trip test or internal load for triggering a
residual current circuit breaker (RCD/FI)
AC/DC
L3
DC and AC voltage
L1
Phase sequence indication
L2
IP
65
LED
Display with LED
LCD
Display with LCD
Water-resistant (spray, jets of water)
Lighting of measurement points
Dust-resistant
Resistance measurement (e.g. 0...2 kΩ)
0…2 k
Back light
Data
Hold
V
non contact
IP protection category (e.g. IP65)
Measurement memory for barely visible
or readable measurement results
Non-contact detection of AC voltage
No battery needed
Detecting magnetic fields
Alternating current
Acoustic recognition of (alternating) current
no battery
AC
CAT IV
600 V
Disclosure of measurement category in accordance with
EN 61010, DIN VDE 0411
10
11
13
14
Voltage detectors
Model
2100-ALPHA
2100-BETA
2100-GAMMA
VOLTfix plus
VOLTfix Drill
MAGNO-VOLTfix
Model.
2100-ALPHA
2100-BETA
2100-GAMMA
2052-D
2054-D
2050-D
Display
LED bar chart
display
LED bar chart display
LCD 3-1/2-digit
LED bar chart display
LCD 3-1/2-digit
1 LED
2 LEDs
2 LEDs
Range/resolution
12, 24, 50, 120,
230, 400, 690 V
12, 24, 50, 120,
230, 400, 690 V
12…690 V / 1 V
12, 24, 50, 120, 230,
400, >690 V,
6...1000 V AC,
6...1200 V DC / 1 V
50…600 V AC
50…600 V AC
50…600 V AC
Tolerance AC/DC
in accordance with
DIN VDE 0682-401
in accordance with
DIN VDE 0682-401
in accordance with
DIN VDE 0682-401
< 3.5 mA (690 V)
< 3.5 mA (690 V)
<3.5 mA AC at 1000 V AC/
<4.5 mA DC at 1200 V DC
Basic load (at voltage)
Approximately
2.4 W at 690 V
Approximately
2.4 W at 690 V
Approximately 3.5 W at
1000 V AC/approx. 5.4 W at
1200 V DC
Automatic turn-on threshold
Approximately
12 V
Approximately 12 V
LED: >12 V, LCD: >6V
Approximately
50 V
Approximately
50 V
Approximately
50 V
Measurement Category
CAT IV / 600 V
CAT III / 690 V
CAT IV / 600 V
CAT III / 690 V
CAT IV / 600V
CAT III / 1000 V
CAT III / 600V
CAT III / 600V
CAT III / 600V
DC, 16.7... 400 Hz
DC, 16.7... 400 Hz
DC, 16.7...400 Hz
50…500 Hz
50…500 Hz
50…500 Hz
overall area
overall area
overall area
340...400 VAC /
47....63 Hz
340...400 VAC /
47....63 Hz
170...1000 VAC /
40....70 Hz
0…500 kΩ
optically/acoutically
0…500 kΩ
optically/acoustically
0…500 kΩ optically/acoustically
Low resistance indication:
<10-50 Ω
0…3 MΩ
<5μA
<5μA
<5μA
Approximately
0.3μA
Voltage test
Test current (at voltage)
Frequency
Voltage test
Polarity
Phase sequence detection
Continuity test
Area/Signaling
Test Current
Resistance Measurement
0...1999 Ω
Overall
Approximately 300 W at
1000 VAC /
Approximately 420 W at
1200 VDC
Additional load
Approximately
240 W at 690 V,
≤ 200 mA
Approximately 240 W
at 690 V,
≤ 200 mA
On-time recovery time
max. 30 s/240 s
max. 30 s/240 s
max. 30 s/240 s
2 x 1.5 V, IEC LR03
2 x 1.5 V, IEC LR03
2 x 1.5 V, IEC LR03
Voltage AC/DC testing
•
•
•
Automatic range selection
•
•
•
Single-pole phase testing
•
•
•
Power supply
Non-contact voltage indicator/
electrical field (NCV/EF)
Automatic internal nominal load
Accessory Case
Features
•
•
•
constant
2 x 1.5 V, IEC LR03
AC only
constant
2 x 1.5 V, IEC LR03
AC only
constant
2 x 1.5 V, IEC LR03
AC only
•
•
•
•
•
CC-VP-7xx
CC-VP-7xx
CC-VP-7xx
Continuity measurement, single-pole phase test,
lighting of measurement points
Continuity measurement, single-pole
phase test, lighting
of measurement
points, digital LCD
Resistance measurement
range, low resistance continuity test, single-pole
phase test, lighting of
measurement points, digital
LCD, NVC
9
Electrical testing equipment | Voltage testers
2100-ALPHA
Voltage and continuity
tester with phase sequence
indication
Functions
• Voltage test
• Optical and acoustic continuity and voltage test
• Patented phase rotation indicator, no 3rd hand
required
• Single-pole phase test
• Polarity
Product information
AC/DC
Rx
L3
• Switchable load (load tester) of 240 W
via two push buttons, triggering a
RCD/FI up to 30 mA
• IP 64, water and dust-resistant
• Integrated probe-tip protection for
reducing the danger of injuries
• Fully functional voltage indicator even
without batteries or if batteries are empty
1
L1
0
RCD / FI
L2
IP
64
LED
Product highlights
CAT IV
600 V
• No unintentional triggering of
RCD/FI circuit breakers
• Fast single-handed testing of power sockets
with 19 mm contact clearance, without the
probe coming away from the unit
• Lighting of measurement points via white LED
• Extremely robust construction with doubly insulated wires
CAT III
690 V
Technical specifications
Display
Voltage range
Direct current /
alternating current
Frequency range
Internal nominal load
Test current
Switchable load
Test current with load
Rotating field definition
Frequency range
Single-pole phase test
Voltage range
Frequency range
Continuity test
Switching threshold
Test current
Safety cert
Measurement
Pollution Degree
Protection Category
Power supply
Current consumption
Dimensions
Weight
LED bar graph display
±12, ±24, 50, 120, 230, 400,
690 V
Graphical LCD, 12…690 V AC/DC
12...690 V AC/DC
automatic recognition
DC 16 2/3 Hz... 400 Hz
approx. 2.4 W at 690 V
≤3.5 mA (without key activation)
approx. 240 W (at 690 V)
≤ 350 mA
340…440 V AC (phase conductor)
47…63 Hz
180 ... 690 V AC
40…70 Hz
approx. 500 kΩ
<5 μA
DIN VDE 0682-401, EN 61243-3
CAT IV / 600 V, CAT III / 690 V
2
IP 64, water and dust-resistant
2 x battery 1.5 V Micro, IEC LR03
max. 60 mA
approx. 280 x 78 x 35 mm
approx. 320 g
2100-BETA
Voltage and continuity tester with
phase sequence indication
As the 2100-ALPHA, also with:
• Digital LCD 12…690 V AC/DC
AC/DC
IP
64
Rx
L3
1
L1
0
L2
RCD / FI
LED LCD
CAT IV
600 V
CAT III
690 V
Data
Hold
Accessories:
Carrying case
Model CC-VP-7xx
Spare part: 2100-ACCS
4 mm probe extenders and probe
tip covers
Model 2100-ACCS
10
Scope of delivery 2100 ALPHA/BETA:
1 x 2100-ALPHA or 2100-BETA
2 x probe cover (GS38)
2 x 4-mm-probe extenders (screwable)
2 x batteries 1.5 V, IEC LR 03 (AAA), Micro
1 x user manual
Ordering Information:
Description
Model
2100-ALPHA
2100-ALPHA* 4312495
2100-BETA
2100-BETA*
4312508
Carrying case
CC-VP-7xx
3889931
2100-ACCS (Spare part) 2100-ACCS
Article no.
4736214
* Packing unit of 10 items (also available individually)
Voltage detectors/lamp testers
2100-GAMMA
Technical specifications
Voltage and continuity tester
with phase sequence indication,
resistance measurement and NCV
Functions
AC/DC
Rx
L3
1
L1
Data
Hold
0
L2
IP
64
RCD / FI
V
LED
LCD
CAT IV
600 V
non contact
CAT III
1000 V
• Voltage test up to 1000 V
alternating current and 1200 V direct current
• Digital LCD 12…1000 V AC/ 1200 V DC
• Measures resistance up to 1999 Ohm
• Optical and acoustic continuity and voltage test
• Low resistance continuity measurement
<10...50 Ohm
• Patented phase rotation indicator,
no 3rd hand required
• Single-pole phase test
• Polarity
• Non-contact voltage (NCV/EF) detection
Product information
• Switchable load (load tester) of 300 W at
1000 VAC / 420 W at 1200 VDC via
two push buttons, triggering a
RCD/FI up to 30 mA
• IP 64, water and dust-resistant
• Integrated probe-tip protection for reducing the
danger of injuries
Product highlights
Included:
1 x 2100-GAMMA
2 x probe cover (GS38)
2 x 4-mm probe extenders (screwable)
2 x batteries 1.5 V, IEC LR 03 (AAA), Micro
1 x user manual
• No unintentional triggering of RCD/FI circuit
breakers
• Fast single-handed testing of power sockets
with 19 mm contact clearance, without the
probe coming away from the unit
• Lighting of measurement points via white LED
• Extremely robust construction with doubly insulated wires
Accessories:
Carrying case
Model CC-VP-7xx
Spare part: 2100-ACCS
4 mm probe extenders and probe
tip covers
Model 2100-ACCS
Ordering Information:
Description
Model
2100-GAMMA
2100-GAMMA*4709243
Carrying case
CC-VP-7xx
2100-ACCS (Spare part) 2100-ACCS
Article no.
3889931
Functions
• Testing fluorescent lamps of various types
• Non-contact voltage detection
• Direct testing of lamp contacts
Product information
V
non contact
Included:
1 x LT-10-EUR
1 x antenna, 122cm
1 x adapter plate for fluorescent tubes
1 x antenna for sodium vapour lamps
1 x carrying case
1 x user manual
automatic recognition
DC, 16 2/3 Hz…400 Hz
approx. 3.5 W at 1000 VAC /
5.4 at 1200 VDC
Test current
≤3.5 mA at 1000 VAC /
≤4.5 mA at 1200 VDC
(without key activation)
Switchable load
approx. 300 W at 1000 V AC/
Approximately 420 W at 1200 VDC
Test current with load ≤300 mA AC at 1000 V AC/
≤350 mA DC at 1200 V DC
Rotating field definition 170…1000 V AC
(phase conductor)
Frequency range
40…70 Hz
Single-pole phase test
Voltage range
100 ... 1000 V AC
Frequency range
40…70 Hz
Continuity measurement of switching threshold
approx. 500 kΩ
Test current
<5 μA
Resistance measurement range/resolution
0...1999 Ω/1 Ω
Test current
<30 μA
Low resistance indication acoustic indication <10…50 Ω
Overvoltage protection 1000 V AC/1200 V DC
Non-contact voltage indicator (NCV/EF)
Voltage range
100…1000 V AC
Frequency range
50…60 Hz
Display
Three-stage display via
LCD segments
Safety cert
DIN VDE 0682-401, EN 61243-3
Measurement
CAT IV / 600 V, CAT III / 1000V
Pollution Degree
2
Protection Category
IP 64, water and dust-resistant
Power supply
2 x battery 1.5 V Micro, IEC LR03
Current consumption max. 60 mA
Dimensions
approx. 280 x 78 x 35 mm
Weight
approx. 320 g
* Packing unit of 10 items (also available individually)
Lamp Tester
LED
Voltage range
Direct/
Alternating current
Frequency range
Internal nominal load
LED bar graph display
±12, 24, 50, 120, 230, 400, ≥690V
LCD, 6…1000 V AC/
1200 V DC
6…1000 V AC/ 1200 V DC
4736214
LT-10-EUR
AC
Display
• Simple single-hand/1-button operation
• Extremely compact - pocket-size design
• Compatible with the most common
fluorescent lamps:
- T2, T4, T5, T8, T9, T10, T12
- energy-saving fluorescent lamps
• Including sodium vapour lamp antenna for
testing additional lamps:
- Sodium vapour low-pressure lamps
- Sodium vapour high-pressure lamps
- Fluorescent tubes
- Mercury vapour lamps
- Halogen metal vapour lamps
Device highlight
• Integrated, highly-sensitive 122 cm antenna
(can be removed and inserted) enables testing
of both lamp and voltage without a conductor
Technical specifications
Display
Test voltage
(with new battery)
Non-Contact
Field strength:
Voltage test:
Overall
Safety cert.:
Measurement category
Pollution Degree
Protection category
Power supply
Dimensions
Weight
1 LED
approx. 3 kV / 280 kHz
Approx. 100 μV/m at 260 - 300 kHz
AC 90 V to AC 600 V, 50/60
EN61010/IEC61010
CAT II/300 V, CAT I/600 V
2
IP 40
1 x battery 9V, 6LR61
170 x 40 x 24 mm
approx. 100g (incl. batteries)
Ordering Information:
Description
Model
Article no.
LT-10-EUR
LT-10-EUR
4386345
LT-10-ANT (Spare part) LT-10-ANT
4357839
11
Electrical testing equipment | Voltage testers
VOLTfix plus
Non-contact volt probe
Functions
• Non-contact, optical and acoustic detection of
AC voltages
• Fast, accurate detection of cable breaks in
open-ended cables, e.g. cable drums or extension cables
Product information
• Reliable, automatic self-test of activated device
with optical readiness indicator
• Compact, handy design that fits in any pocket
• Wide range of applications in trade and industry
Technical specifications
Display
1 LED
Voltage range
50…600 V AC
Frequency range
50...500 Hz
On-time
constant
Pollution degree
2
Measurement category CAT III/600 V
Safety cert.:
DIN VDE 0411,EN 61010
Power supply
2 x battery 1.5 V, IEC LR03
Dimensions
140 x 24 x 20 mm
Weight
approx. 50 g
Device highlight
LED
AC
V
• On/off switch
non contact
Included:
Ordering Information:
Description
1 x VOLTfix plus
2 x battery 1.5 V, IEC LR03
1 x user manual
VOLTfix plus
VOLTfix Drill
Non-contact voltage probe with
screwdriver insert
Functions
• Non-contact, optical and acoustic detection of
AC voltages
• Direct voltage test via screwdriver blade
• Continuity test
• Fast, accurate detection of cable breaks in
open-ended cables, e.g. cable drums, extension
cables
Product information
AC
Rx
LED
V
non contact
Included:
• Reliable, automatic self-test of activated device
with optical readiness indicator
• Compact, handy design that fits in any pocket
Model
Article no.
2052-D*
3454347
Technical specifications
Display
2 LEDs
Voltage range/
50…600 V AC
Frequency
Voltage
50…500 Hz
Continuity test
0... 3 MΩ
Test current
approx. 0.3 μA
On-time
constant
Pollution degree
2
Measurement category CAT III/600 V
Safety cert.:
DIN VDE 0411, EN 61010
Power supply
2 x battery 1.5 V, IEC LR03
Dimensions
160 x 25 x 21 mm
Weight
approx. 55 g
Device highlight
• Integrated, ultra-bright flashlight
• Fixed, high-quality screwdriver insert (chrome,
vanadium, molybdenum blade)
Ordering Information:
Description
1 x VOLTfix drill
2 x battery 1.5 V, IEC LR03
1 x user manual
VOLTfix drill
MAGNO-VOLTfix
Non-contact voltage probe with
magnetic field detection
Functions
• Non-contact, optical and acoustic detection of
AC voltages
• Fast, accurate detection of cable breaks in
open-ended cables, e.g. cable drums, extension
cables
• Optical signal for detection of magnetic fields,
e.g. on magnetic coils or permanent magnets
Model
Article no.
2054-D*
3454358
Technical specifications
Display
2 LEDs
Voltage range/
50…600 V AC
Frequency
Voltage
50…500 Hz
On-time
constant
Pollution degree
2
Measurement category CAT III/600 V
Safety cert.:
DIN VDE 0411, EN 61010
Power supply
2 x battery 1.5 V, IEC LR03
Dimensions
140 x 24 x 20 mm
Weight
approx. 50 g
Product information
• Compact, handy design that fits in any pocket
• Wide range of applications in trade and industry
AC
LED
Included:
1 x MAGNO-VOLTfix
2 x battery 1.5 V, IEC LR03
1 x user manual
V
non contact
Ordering Information:
Description
MAGNO-VOLTfix
Model
Article no.
2050-D*
3454335
* Packing unit of 10 items (also available individually)
12
Continuity testers/battery testers
TESTFIX
Continuity and circuit tester with
flashlight function
Technical specifications
Continuity test
Test current
Functions
• Acoustic continuity tester (summer)
• Optical continuity display (lamp)
Product information
• Low-resistance continuity tester
• For testing light bulbs, fuses, etc.
• Test wiring and grid networks
Test voltage
Power supply
Dimensions
Weight
0…10 Ω (optical),
0…100 Ω (acoustic)
approx. 200 mA (optical)
Approx. 40 mA (acoustic)
< 4.5 V
3 x battery 1.5 V, IEC LR6
130 x 75 x 35 mm
approx. 180 g
Product highlights
• Flashlight function with continuous light
Rx
Included:
Ordering Information:
1 x TESTFIX without batteries
1 x spare lamp
1 x carrying case
2 x uninsulated crocodile clips
1 x user manual
Description
Model
Article no.
TESTFIX
9023*
2147430
* Packing unit of 10 items (also available individually)
Ohmtest
Continuity tester
Functions
• Continuity tester with buzzer
• Optical continuity display
• External voltage display >50 V
Product information
• Range of applications: Resistance, semi-conductor, and polarity testing, light-bulbs, fuse, etc.
Technical specifications
Continuity test
Test current
Test voltage
External voltage
indicator
Protection category
Power supply
Dimensions
Weight
0...500 kΩ
approx. 5 μA
<9V
50....600 V
IP 40
1 x battery 9 V, IEC 6LR61
110 x 58 x 24 mm
approx. 150 g
Device highlight
• Voltage-proof up to 600 V
Rx
LED
Included:
Accessories:
Ordering Information:
Description
1 x Ohmtest
1 x battery 9 V, IEC 6LR61
1 x crocodile clip
2 x probes
1 x user manual
Carrying case
Model 1150
Model
Ohmtest
9072-D*
Carrying case
1150
Article no.
3454373
2145755
* Packing unit of 10 items (also available individually)
BAT-250-EUR
Battery tester
Functions
• Test standard and rechargeable batteries
• Direct display of state of charge
• Analog display with colored areas
Product information
• Testing of Mignon (AA), Micro (AAA), Baby (C),
and Mono (D) battery types
• Testing of 1.5 V button cells
• Testing of 9 V block batteries
Product highlights
Included:
1 x BAT-250-EUR
1 x user manual
• Ergonomic design, sliding contact for one-handed operation
• V-shaped battery holder on the side
• High-quality connections for 9 V block batteries
• No batteries required to operate
Technical specifications
Display
Analog display with colored
areas
Replace (REPLACE), Low (LOW),
Good (GOOD)
Test current (typical) 1.5 V: 375 mA, 9 V: 40 mA (at
limit of measurement range)
Nominal load (typical) 1.5 V: 4 Ω, 9 V: 215 Ω
Battery types
9 V block battery, Micro (AAA),
Mignon (AA), Baby (C), Mono (D)
and 1.5 V button cells
Dimensions
approx. 110 x 74 x 29 mm
Weight
approx. 50 g
Ordering Information:
Description
Model
BAT-250-EUR
BAT-250-EUR
Article no.
4620297
13
Electrical testing equipment | Phase sequence indicator
PRM-5-EUR
Phase Rotation Tester
Functions
• Phase sequence display with LEDs
• Display of a missing or incorrectly connected
outer conductor
Product information
• Fast detection of phase sequence in three-phase
supply
• Voltage range from 100 to 700 V, Frequency
range 16 to 400 Hz
Technical specifications
Display
LED for anticlockwise, clockwise, faulty connection
Voltage range
100 ... 700 V
Frequency range
16 ... 400 Hz
Test current
≤3,5 mA
Safety cert
DIN VDE 0411/EN 61010-1/
DIN VDE 0413-7, EN 61557-7
Measurement category CAT IV / 600 V
Power supply
from test object
Dimensions
137 x 65 x 33 mm
Weight
approx. 253 g
Product highlights
L3
• No battery needed
• Robust housing with rubber protective cover
• Securely connected test leads
Measurement category CAT IV, 600 V
L1
no battery
L2
AC
Included:
Accessories:
Description
1 x PRM-5-EUR
3 x probes
1 x crocodile clip
1 x carrying case
1 x user manual
Unidreh accessory set
Model 1324
Carrying case
Model 1150
Accessories
1324 Unidreh accessory set allows a perfect and
easy connection to CEE 16 A and CEE 32 A sockets,
safety cert.: CAT II, 1000 V
Crocodile clips for conductor rails
Model 391511 (red)
Model 391512 (black)
4375961
1324
2146183
Carrying case
1150
2145755
Crocodile clip for conductor rail
Red
391511
2146861
Black
391512
2146877
Functions
• Fast detection of phase sequence in three-phase
supply
• Voltage range from 40 to 700 V, Frequency
range 16 to 400 Hz
L2
PRM-5-EUR
UNIdreh accessory set
Display
Phase sequence
indication
Product information
Product highlights
• Robust housing with rubber protective cover
• Detachable test leads
• Measurement category CAT IV, 600 V
• Back light
• Testing rotary field direction possible without
batteries, or with empty batteries
Article no.
PRM-5-EUR
Technical specifications
• Phase sequence display with LCD
• Display of a missing or incorrectly connected
outer conductor
• Non-contact motor rotation indicator when the
motor is running
• De-energised identification of motor connections (U, V, W) via a manual drive
L1
Model
PRM-6-EUR
Motor and Phase Rotation Tester
L3
Ordering Information:
Non-Contact
Motor rotation
indicator
Detection of
motor connections
Test current
Safety cert
LCD
40...700 V / 16....60 Hz
50...700 V / 60....400 Hz
16....400 Hz
>0.65 V / 2....100 Hz
≤3,5 mA
DIN VDE 0411/EN 61010-1/
DIN VDE 0413-7, EN 61557-7
Measurement category CAT IV / 600 V
Power supply
2x batteries 1.5 V, IEC LR 03 (AAA),
Micro
Dimensions
137 x 65 x 33 mm
Weight
approx. 170 g
AC
Included:
1 x PRM-6-EUR
2 x batteries 1.5 V, IEC LR 03
3 x test leads
3 x probes
3 x crocodile clips
1 x carrying case
1 x user manual
Accessories:
Description
Unidreh accessory set
Model 1324
Carrying case
Model 1150
Crocodile clips for conductor rails
Model 391511 (red)
Model 391512 (black)
TL-PRM-6 test lead set for
PRM-6-EUR
Model TL-PRM-6
14
Ordering Information:
Model
Article no.
PRM-6-EUR
PRM-6-EUR
4633222
UNIdreh accessory set
1324
2146183
Carrying case
1150
2145755
Crocodile clip for conductor rail
Red
391511
2146861
Black
391512
2146877
TL-PRM-6 test lead set for PRM-6-EUR
(Spare part)
TL-PRM-6
4692870
Measuring solar radiation
Products
SOLAR-100
15
Symbols used in this chapter
15 sec
Data
Hold
Fast measurement
Measurement Memory
Min/MAX memory
SOLAR-100
Solar Power Meter
Functions
• Measuring solar radiation
• Establishing light transparency of windows and
panes (g-factor)
Product information
• Display switchable between W/m² or
BTU / (ft² x h)
• Manual range selection
• Integrated measurement memory (data hold)
• MAX/MIN function
• Manual zero adjustment
15 sec
Data
Hold
Included:
1 x SOLAR-100
1 x battery 9 V, IEC 6F22
1 x carrying case
1 x user manual
Technical specifications
Display
LCD, 3 ½ digit, 1999 digits
Measurement ranges 0...200, 2000 W/m²,
0…634 BTU / (ft² x h)
Resolution
0.1, 1 W/m²; 0.1, 1 BTU
Accuracy
±10W/m² (±3 BTU) or
±5 %
Power supply
1 x battery 9 V, IEC 6F22
Dimensions
130 x 63 x 38 mm (unit)
80 x 55 x 29 mm (sensor)
Weight
approx. 230 g
Ordering Information:
Description
Model
SOLAR-100
SOLAR-100
Article no.
3474979
15
Locating and measuring
wires/cables
Cable locators are useful for tracing and
finding wires and cables.
This means that sockets and fuses can be
assigned to circuits, hidden sockets and
junction boxes in walls, floors, and ceilings
can be traced, and interruptions in cables and
short circuits can be located.
• Targeted locating of cables in walls, as well
as interruptions and short circuits in cables
• Locating of fuses/machines and assignment
to circuits
• Locating of accidentally concealed sockets
and distribution boxes
• Locating of interruptions and short circuits in
unshielded underfloor heating
• Tracing wires in ceilings and walls
• Tracing cables in soil
Interesting facts
Cable locators
18
Products
Cable locators
16
20
Cable locators | Cable locators
AT-7000-EUR Features and Functions
Trace Wires Inside Conduit
Detect and trace energised and de-energised wires that are surrounded by metal
conduits by removing the cover off the junction box and using the sensor tip of the
AT-7000-RE receiver to identify the exact wire that transmits the signal generated by
the AT-7000-TE transmitter. Wires in non-metal conduits can be traced directly without
opening the junction box and using the AT-7000-RE Receiver’s Smart Sensor™.
Trace energised or de-energised wires by
removing the junction box cover.
Find energised wires without direct connection to wires, signal feed
via current clamp
The SC-7000-EUR current clamp accessory can be used with the AT-7000-TE transmitter
to induce a signal into energised and de-energised wires when direct access to the
wires is neither possible, nor desired. Simply clamp around the desired wire to induce
the signal, then begin tracing.
Induce signal with the current clamp
when there is no bare conductor.
Use the Tip Sensor to trace wires in hard to reach areas
When used with the AT-7000-TE transmitter, the tip sensor pinpoints the location
of energised and de-energised wires in tight, hard to reach spaces. It easily and
accurately traces the targeted energised and de-energised wires in junction boxes,
corners, walls, floors and ceilings to a depth of up to approx. 6 meters (20 feet).
Use the Tip Sensor to trace wires in hard
to reach areas.
Non-contact voltage (NCV) detection
The NCV feature extends functionality of the AT-7000-RE receiver by detecting
energised wires from 90 to 600 V and 40 to 400 Hz without the use of the AT-7000TE transmitter. Its adjustable sensitivity fits a range of applications, from detecting
presence of voltage (higher sensitivity) to precisely pinpointing a hot wire in a bundle
(lower sensitivity).
Non-contact voltage (NCV) detection.
17
Cable locators | Cable locators
Cable locator AT-7000-EUR
Transmitter
Receiver
Theoretical operating principle
The cable locator consists of a transmitter
and the receiver.
The signal generated by the transmitter
consists of a modulated current, which
generates an electromagnetic field
around a conductor.
This electromagnetic field, that is set
up around the conductor, induces a
current in the nozzles on the receiver.
The induced current is amplified by the
receiver, decoded, converted into the
original signal, and then appears in the
display.
The transmitter must always be
connected for such an application such
that a closed circuit is the result.
Types of application
1. Single-pole application: connection of the transmitter to
only one conductor
2. Double-pole application: connection of transmitter to the
grid
The receiver is powered by the built-in battery (rechargeable)
in this operating mode. As the signal generated by the
transmitter is of high-frequency origin, then only a single
conductor can be searched or traced.
The transmitter is powered by the grid. In such a case the
modulation current flows from the transmitter, for example in
the phase, to the transformer and then back to the transmitter
via the neutral conductor.
The second conductor replaces earth. In this arrangement a
high-frequency current flows through the conductor via the air
and back to earth in a similar manner as with a radio transmitter
and radio receiver.
A further opportunity is available for de-energised systems,
where the transmitter is connected to the start of two cables
and then the ends of the cables are short-circuited. This also
results in a closed circuit. The transmitter is then powered by
the built-in battery. The cable locator can only locate cables that
are correctly connected in accordance with physical principles.
18
Cable locators | Cable locators
Locating interruptions in cables
(single-pole application)
The signal is transmitted to the wire that is suspected to be
interrupted. The other wires are connected with the ground
jack on the transmitter, and with an earth. The signal is
traced with the receiver. The signal breaks off at the point
where the interruption takes place.
In closed circuits (double-pole application)
Closed circuits are suitable, for example, for locating
sockets, switches, fuses, etc. in domestic installations that
are energised. This application is possible either when
de-energised, or energised (from 90 - 270 V). The tracing
depth is approximately 0. . . 10 cm.
Tracing fuses
19
Cable locators | Cable locators
AT-7000-EUR series
Multi-function wire tracer
Functions
• Targeted locating of cables in walls, as well as
interruptions and short circuits in cables
• Locating fuses/machines and assignment to
circuits
• Locating accidentally concealed sockets and distribution boxes
• Locating interruptions and short circuits in
unshielded underfloor heating
• Tracing metallic water and heating pipes
Product information
• Set consisting of transmitter and receiver in a
stable, shock-proof case
• Display of sender signal
• Clear, easy-to-follow instruction manual with
application examples
Product highlights
• All application areas (live or de-energised) are
covered without the need for additional devices
• Receiver with high-resolution 8.9 cm (3.5") TFTLCD color screen
• Display of position and direction of wire on LC
screen
• Receiver with two antennas - "Smart Sensor™"
and "Tip Sensor"
• Transmitter with two switchable transmission
frequencies (6 kHz and 33kHz)
• Connection for optional current clamp to feed
in a signal without direct connection to the
wire.
AT-7020-EUR
AT-7000-RE Receiver
Transmitter AT-7000-TE
3 test leads
2 x crocodile clips
2 x probes
10x batteries 1.5 V, IEC LR 06 (AA), Mignon
1 x carry case
1 x user manual
Technical specifications
Display
TFT-LCD color screen, 8.9 cm
(3.5“), 70 x 53 mm
with backlit display
Resolution
320 x 240 pixels
Measurement frequencies energised: 6.25 kHz
De-Energised: 32.768 kHz
Tracing depth
Smart sensor
approx. 5 cm ... approx. 1.5 m
Tip sensor,
energised
approx. 5 cm ... approx. 6.7 m
Tip sensor, de-energised approx. 5 cm ... approx. 4.3 m
Non-Contact
Voltage test
approx. 5 cm ... approx. 1.2 m
Non-contact voltage
detection (NCV)
approx. 90 ... 600 V AC
Safety cert
DIN VDE 0411/EN 61010-1
Measurement category CAT IV / 600 V
Power supply
4x batteries 1.5 V, IEC LR 06 (AA),
Mignon
Energy intake
2W
Dimensions
280 x 113 x 65 mm
Weight
approx. 540 g
Transmitter AT-7000-TE
Display
TFT-LCD, 4.5 cm (1.77“), 28 x 35 mm
with backlit display
Resolution
128 x 160 pixels
Measurement frequencies energised 6.25 kHz
de-energised 32.768 kHz
Voltage measurement 9 ... 300 V AC/DC 0 ... 400 Hz
Safety cert
DIN VDE 0411/EN 61010-1
Measurement category CAT IV / 300 V
Power supply
6x batteries 1.5 V, IEC LR 06 (AA),
Energy consumption
2W
Dimensions
216 x 100 x 56 mm
Weight
approx. 590 g
Ordering Information:
Description
Model
Article no.
AT-7020-EUR
AT-7020-EUR
4542794
AT-7030-EUR
AT-7030-EUR
4542782
Receiver
AT-7000-RE
4542802
Transmitter
AT-7000-TE
4542816
Recommended Accessories
AT-7030-EUR
AT-7000-RE Receiver
Transmitter AT-7000-TE
SC-7000-EUR Current clamp
BR-7000-T power pack
Hanging strap HS-1
3 test leads
2 x crocodile clips
2 x probes
10x batteries 1.5 V, IEC LR 06 (AA), Mignon
1 x carry case
1 x user manual
Accessories:
1. Current clamp
SC-7000-EUR
1
2
2. Hanging strap for transmitter
HS-1
3. Power pack for transmitter
BR-7000-T
4. Battery charger
BR-7000-C
3
4
5
5. Test leads 25 m
TL-7000-25M
20
Current clamp
SC-7000-EUR
Hanging strap for transmitter
4594135
Power pack for transmitter
4467296
4542825
HS-1
BR-7000-T
4544583
Battery charger
BR-7000-C
Test lead 25 m
TL-7000-25M 4634011
Cable locators/fuse finders
Cable Locator Set
for live and de-energised circuits
Functions
• Targeted locating of cables in walls, as well as
interruptions and short circuits in cables
• Locating of fuses and assignment to circuits
• Locating of accidentally concealed
sockets and distribution boxes
• Locating of interruptions and short circuits in
unshielded underfloor heating
• Tracing of metallic water and heating pipes
Product information
• Set consisting of transmitter and receiver in a
robust, shock-proof case
• Transmitter signal is indicated optically and
acoustically
• Clear, easy-to-follow instruction manual with
application examples
Included:
1 x cable locator receiver
1 x cable locator transmitter, code "F"
4 x test leads
3 x battery 9 V, IEC 6LR61
2 x crocodile clips
2 x probes
1 x carry case
1 x user manual
Product highlights
• All application areas (live or
de-energised) are covered without the need for
additional devices
• Accurate locating by means of displaying a
specified letter on the receiver
ECB50A
Fuse finder for live circuits
Functions
• Fast and accurate locating of fuses and assignment to circuits
• Locating and tracing of cables beneath plaster
Product information
• Set consisting of transmitter and receiver in a
robust carry case
• Transmitter signal is indicated optically and
acoustically on the receiver
• Transmitter with built-in Schuko plug for simple
contacting with the Schuko or UK socket
• Simple switching between fuse and cable search
function
• Continuous sensitivity adjustment of receiver
• Coded signal enables precise identification from
the receiver
Included:
1 x fuse finder transmitter
1 x fuse finder receiver
1 x battery 9 V, IEC 6LR61
1 x carry case
1 x user manual
* This product is not available in Switzerland
* For UK: circuit breaker finder ECB50A-E
available with UK plug
* For EUR (except UK): ECB50A-FGIS with Schuko
plug
Technical specifications
Display
LED bar for intensity and
7-segment display on receiver for
number or letter indicating the
transmitter code
Tracing depth
0...40 cm
Withstand voltage
250 V
Measurement category CAT II/250 V
Pollution degree
2
Safety cert.:
EN 61010-1/IEC 61010
Power supply
1 x battery 9 V, IEC 6LR61
(receiver)
2 x battery 9 V, IEC 6LR61
(transmitter)
Dimensions
380 x 305 x 90 mm (case)
Weight
approx. 1.8 kg
Ordering Information:
Description
Model
Article no.
Cable locator set
in case
2032-D
3454320
Technical specifications
Receiver display
2 LEDs and 7-segment display
for letters for displaying the code
from the transmitter
Tracing depth
Function fuse 0…10 cm
Function wire 0…40 cm
Voltage range
100…250 V AC (50…60 Hz)
Measurement category CAT III/300 V
Pollution degree
2
Safety cert.:
EN 61010-1/IEC 61010
Power supply
1 x battery 9 V, IEC 6LR61
(receiver)
network supply
(transmitter)
Dimensions
180 x 120 x 45 mm (case)
Weight
approx. 250 g (set)
Ordering Information:
Description
Model
ECB50A-E
ECB50A-FGIS
ECB50A-E
ECB50A-FGIS
Article no.
3027097
3027106
21
Cable locators| Cable locators/cable testers
AT-3500
Underground cable locator
With the AT-3500 cable locator you
can ensure that productivity remains
high, whilst costs remain low. AT-3500
is a robust, cost-effective solution for
locating live and de-energised wires,
cables and pipes in soil.
The cable locator is, for example, suitable
for car park and airport lighting, and
shows the location of cables and pipes
immediately on a digital, backlit multisegment display, complete with acoustic
indicators.
22
The AT-3500 cable locator functions at
the frequency of 33 kHz, which is proven
for the majority of tracing applications. In
order to avoid wires on construction sites,
the device also provides a highly-sensitive
current mode and a radio mode. Depth
measurements can be carried out by
pressing the button.
Cable locators/cable testers
AT-3500
Underground Cable /
Pipe Locator System
Functions
• Locating and tracing cables and pipes in the
ground
• Simplified tracing function enables location of
cable or pipe damage
• Determining the location, depth, and alignment
of metal cables
• Optical and acoustic display
Product information
• Set consists of transmitter, receiver, and measuring accessories
• Various measurement functions allow for high
levels of accuracy:
- Passive via network frequency
- Passive via radio signals
- Active via signal generator
• Transmitter with voltage-proof output
• Comprehensive range of accessories available
Product highlights
• Large display with simple menu navigation and
back light
• Robust construction for use in inclement weather and harsh environments
Technical specifications
Transmitter T-3500
Transmission power
Frequency
Power supply
Operating time
Protection category
Dimensions
Weight
Receiver R-3500
Frequency ranges
Sensitivity
Depth range
Resolution
Power supply
Operating time
Protection category
Dimensions
Weight
Included:
Accessories:
1 x R-3500 receiver
1 x T-3500 transmitter
1 x user manual
2 x test leads
2 x crocodile clips
1 x earth spike
10 x battery 1.5 V, IEC LR6 / AA / Mignon
6 x battery 1.5 V, IEC LR20/D/Mono
1 x robust carry case
MLS55-3,
Pipe transmitter for AT-3500
order no. MLS55-3
SC-3500, Current clamp
for AT-3500
order no. SC-3500
LAN-1
LAN Cable Tester
Included:
1 x LAN-1
1 x remote coding plug
1 x battery 9 V, IEC 6F22
2 x adapter RJ45/BNC
1 x adapter RJ45/RJ45
2 x adapter BNC/BNC
1 x carrying case
1 x user manual
Range 1: Radio 15 kHz to 23 kHz;
Range 2: Power grid 50 / 60 Hz;
Range 3: Transmitter 32.768 kHz
Range 1: Radio > 20 μA;
Area 2: Power grid > 7 mA; Range
3: Transmitter > 5 μA
0.1 m … 5 m
0.1 m
10 x battery 1.5 V, IEC LR6 / AA /
Mignon
approx. 40 hours
(for operation with interruptions
and with alkali batteries at 20 °C)
IP 67 from the lower edge of the
receiver to the lower edge of
the battery compartment, and
IP 56 for all parts for which this
description is not relevant
approx. 99 x 660 x 252 mm
approx. 2.5 kg
Ordering Information:
Description
Model
AT-3500
AT-3500
MLS55-3
MLS55-3
SC-3500
SC-3500
Display
Product information
• Test pin configuration for:
- 10/100 base
- 10 base-2 cables
- RJ45 cables
- AT&T 258A cables
- EIA / TIA 568A/568B cables
- Token ring cables
• Testing installed cable on wall plate or the patch
panels by using an external coding plug
• Testing a cable loop or remote testing with a
coding plug
• Acoustic error display
Ordering Information:
• Automatic and manual test procedure
• Recognition of split pairs
3435058
3435099
3435073
2x 9 LED segments for
cable occupation green output,
red input
RJ45 and BNC
>300 m
battery 1 x 9 V, IEC 6F22
130 x 56 x 38 mm
approx. 600 g
Connection
Max. cable length
Power supply
Dimensions
Weight
Product highlights
Article no.
Technical specifications
Functions
• Testing wiring faults of LAN cables
• Detection of cable breaks, short circuits,
reversed and split pairs
• Check of shielding
0.1 W/0.5 W (switchable)
32.768 kHz
6 x battery, IEC LR20 / D / Mono
approx. 40 hours
(for operation with interruptions
and with alkali batteries at 20 °C)
IP 56
260 x 255 x 140 mm
1.7 kg (2.65 lb)
Description
Model
LAN-1
LAN-1
Article no.
3052401
23
Digital multimeters
Multimeters are measuring devices
that can measure many variables.
Our product portfolio ranges from
compact multimeters for simple
applications (e.g. troubleshooting)
up to multimeters for more
demanding situations such as in
development or within industry,
with a variety of functions and
measurement options. This means
that regardless of the application,
we have the right multimeter
offering excellent value for money.
Products
Full overview
LCR meters
AM-500-EUR series
Hexagon series
PM series
HD series
Junior set and kits
battery test
Hz
PC
Bargraph
24
Battery test
Back light
Temperature measurement
Diode test and
Continuity beeper
Frequency verification
Data
Hold
Measurement Memory
Capacitance measurement
CAT IV
600 V
Measurement Category
PC interface
True PC measurement
Digital bar graph display
Min/Max Hold
25
27
28
29
30
31
32
0.1 μA…10 A
(20A for 30 s)
50...500 Hz
0.1 μA…10 A
(20A for 30 s)
0.1 mV... 1000 V
(0.3% + 4D)
0.1 μA…10 A
(20A for 30 s)
(1.5% + 4D)
50 Hz...500 Hz
0.1 μA…10 A
(20A for 30 s)
(1.2% + 3D)
0.1Ω…40 MΩ
1 mV... 600 V
(0.8% + 3D)
0.1 μA...10 A
(1.5% + 3D)
45...400 Hz
0.1 μA...10 A
(1.2% + 3D)
1Ω…20 MΩ
•
Voltage DC
Basic Accuracy*
Basic Accuracy*
Frequency
Current DC
Basic Accuracy*
Resistance
Features
Measurement Category
Battery
Auto Power Off
Data logger/interface
Relative measurement
Peak Hold
Acoustic warning signal for
incorrect jack connection
Acoustic warning signal for
incorrect Jack connection
incl. temperature probe
CAT III/600 V,
CAT II/1000 V
CAT III/600V,
CAT II/1000 V
CAT III/600 V
Battery test,
1.5 V/9 V
2 x 1.5 V
2 x 1.5 V
•
•
1x9V
•
•
1x9V
•
- / RS-232
•
•
•
•
•
•
-20...+1300°C
3.00Hz...10MHz
0.01 nF... 400.0 μF
•
0.1Ω…40 MΩ
(0.5% + 10D)
0.01 μA... 10 A
45 Hz...1 kHz
(1.5% + 20D)
0.01 μA... 10 A
(0.25% + 5D)
0.1 mV... 1000 V
45 Hz...2 kHz
(1.2% + 10D)
0.1 mV... 750 V
•
AC+DC
4 digit, 9999 digits
38 XR-A
Current loop measurement
(4….20mA) Software
optionally available
Magnetic hanger
(MagneGripTM)
CAT III/600V, CAT II/1000V CAT III/600V, CAT II/1000V
1x9V
RS-232 interface
Inductance measurement
Illuminated display
Acoustic warning signal in
Calibration and adjustment case of incorrect jack connecwithout opening the device
tion logic test
Software optionally available
Magnetic hanger
(MagneGripTM)
CAT IV/600 V,
CAT III/1000 V
1x9V
•
- / RS-232
•
- / RS-232
•
•
•
•
•
•
•
•
Data Hold
•
•
3.00Hz...10MHz
0.01 nF... 400.0 μF
•
0.1Ω…40 MΩ
(0.5% + 10D)
0.01 μA... 10 A
45 Hz...1 kHz
(1.5% + 10D)
0.01 μA... 10 A
(0.1% + 5D)
0.1 mV... 1000 V
45 Hz...2 kHz
(1.2% + 10D)
0.1 mV... 750 V
•
•
•
Manual
Min/max value memory
•
•
Automatic
Range selection
Max Hold
-50…+1000 °C
-20…+300 °C
Temperature
Max Hold
5 Hz…125 kHz
5 Hz…1 MHz
5 Hz…1 MHz
Frequency
•
0.01 nF... 9999 μA
•
0.01 nF... 3000 μF
Diode and continuity test
•
0.01Ω…50 MΩ
(0.2% + 4D)
0.1 μA…10 A
(20A for 30 s)
40 Hz…1 kHz
(0.6% + 3D)
0.1 μA…10 A
(20A for 30 s)
(0.08% + 2D)
0.01 mV... 1000 V
40 Hz...20 kHz
0.01 nF…3000 μF
0.1Ω…40 MΩ
(1.2% + 3D)
(1.5% + 4D)
0.1 mV... 1000 V
50...500 Hz
(0.5% + 3D)
0.01 mV... 1000 V
Capacitance
Current AC
(0.3% + 4D)
50...500 Hz
45...400 Hz
Frequency
(1.5% + 5D)
(1.5% + 5D)
(1.0% + 3D)
Basic Accuracy*
0.1 mV... 1000 V
0.1 mV... 1000 V
1 mV... 600 V
Voltage AC
Ranges
•
•
Bar graph
37 XR-A
AC
Hexagon 340
4 digit, 9999 digits
3¾ digit, 4000 digits
Hexagon 120
AC
3¾ digit, 4000 digits
Hexagon 110
¾ digit, 5000 digits
31/2 digit, 1999 digits
AM-500-EUR
True-RMS measurement
Display Digits
Model
Overview
* = Basic accuracy figures are with regard to the best level of accuracy of the relevant measurement function
25
26
0.01 Hz...10 MHz
0.01 Hz…10 MHz
Frequency
* = Basic accuracy figures are with regard to the best level of accuracy of the relevant measurement function
Features
Measurement Category
Battery
Auto Power Off
Data logger/interface
Relative measurement
Peak Hold
CAT IV/1000V
CAT IV/1000V
Highest levels of safety
CAT IV/1000V
Illuminated display
Auto power off
1x9V
1x9V
Highest levels of safety
CAT IV/1000V,
Auto Power Off
•
•
•
•
•
•
Data Hold
•
•
•
Min/max value memory
•
•
Automatic
Manual
Range selection
Temperature
Non-contact
voltage detection,
battery test, duty cycle
function
CAT III/600 V
1x9V
•
•
•
•
10 pF...4000 μF
10 pF...100.0 μF
0.01 nF... 400.0 μF
Capacitance
Non-contact
voltage recognition,
True RMS measurement
(TRMS)
CAT III/600V,
CAT II/1000 V
CAT III/600V,
CAT II/1000 V
Non-contact
voltage detection,
min/max
value memory
1x9V
•
•
•
•
•
-40...+1000 °C
0.01 Hz...10 MHz
10 pF...4000 μF
•
0.1 Ω…40 MΩ
(1.0 % + 2 D)
0.1 μA...10 A
45 Hz ...400 Hz
(1.2 % + 3 D)
0.1 μA...10 A
(0.8 % + 1 D)
0.1 mV...1000 V
45 Hz ...400 Hz
(1.0 % + 3 D)
400 mV...750V
AC
3¾ digit, 3999 digits
AM-530-EUR
1x9V
•
•
•
•
•
-40...+1000 °C
0.01 Hz...10 MHz
•
•
•
•
-20…+1300 °C
0.1 Ω…40 MΩ
0.1 Ω...40 MΩ
0.1 Ω…40 MΩ
0.1 Ω…40 MΩ
Diode and continuity test
Resistance
(1.0 % + 2 D)
(1.0 % + 2 D)
(1.5% + 10D)
(1.5% + 10D)
0.1 μA...10 A
Basic Accuracy*
45 Hz ...400 Hz
0.1 μA...10A
0.01 μA...2 A
0.01 μA...2 A
Current DC
45 Hz ... 400 Hz
45 Hz...1 kHz
45 Hz...1 kHz
Frequency
(1.2 % + 3 D)
(1.2 % + 2 D)
(0.8 % + 4 D)
(0.8 % + 4 D)
0.1 μA...10 A
0.1 μA...10 A
Basic Accuracy*
(0.8 % + 1 D)
(0.8 % + 1 D)
(0.1% + 5 D)
0.1 mV...1000 V
1 mV...600V
0.01 μA... 2 A
45 Hz ...400 Hz
45 Hz ... 400 Hz
(0.1% + 5 D)
0.1 mV... 1500 V
0.1 mV... 1500 V
Voltage DC
(1.0 % + 3 D)
(1.0 % + 3 D)
0.01 μA... 2 A
45 Hz...2 kHz
45 Hz...2 kHz
Frequency
400 mV...750V
0.1 mV...600V
•
3¾ digit, 3999 digits
AM-520-EUR
Current AC
(1.2 % + 10 D)
(1.2 % + 10 D)
•
3¾ digit, 3999 digits
AM-510-EUR
Basic Accuracy*
0.1 mV... 1000 V
0.1 mV... 1000 V
AC
4 digit, 9999 digits
HD 160C
Basic Accuracy*
4 digit, 9999 digits
HD 110C
Voltage AC
Ranges
Bar graph
True-RMS measurement
Display Digits
Model
Low pass filter
Dual display
Duty cycle function
Peak value measurement
(crest)
CAT IV/600 V,
CAT III/1000 V
1x9V
Low pass filter
True-rms reading
Dual display
Duty cycle function
Peak value measurement
(crest)
CAT IV/600 V,
CAT III/1000 V
1x9V
•
•
•
•
•
•
•
•
-40...+1000 °C
0.01 Hz...600.0 kHz
60.00 nF...60 mF
•
0.1 Ω…60 MΩ
(1.0 % + 2 D)
0.1 μA...10 A
45 Hz ...400 Hz
(1.2 % + 5 D)
0.1 μA...10 A
(0.5 % + 2 D)
0.1 mV...1000 V
45 Hz... 400 Hz
(1.0 % + 3 D)
1 mV...1000 V
•
AC
3¾ digit, 5999 digits
AM-550-EUR
•
•
•
•
-40...+1000 °C
0.01 Hz...600.0 kHz
60.00 nF...60 mF
•
0.1 Ω…60 MΩ
(1.0 % + 2 D)
0.1 μA...10 A
45 Hz ...400 Hz
(1.2 % + 5 D)
0.1 μA...10 A
(0.5 % + 2 D)
0.1 mV...1000 V
45 Hz... 400 Hz
(1.0 % + 3 D)
1 mV...1000 V
•
3¾ digit, 5999 digits
AM-540-EUR
Digital Multimeters | Overview
LCR meters/multimeters
LCR55A
LCR Meter
Functions
• Measuring resistance
• Capacitance measurement
• Inductance measurement
• Transistor and diode measurement
Product information
• Manual range selection
• Integrated measurement memory (data hold
and MAX hold)
• Shock-proof and impact-resistant thanks to
standard protective holster
• Auto Power Off
Product highlights
Manual
Range
• Large, clear display
Data
Hold
Included:
Accessories:
1 x LCR55A
2 x test leads
2 x crocodile clips
1 x battery 9 V, IEC 6LR61
1 x user manual
Soft Case
Model CC-ACDC
AM-500-EUR
Compact digital multimeter
Functions
• Voltage, current and resistance measurement
• Diode and acoustic continuity test
Device information
• Automatic and manual range selection
• Integrated measurement memory (data hold)
• Shock-proof and impact-resistant thanks to
standard protective holster
• μA measurement range
• Auto Power Off
Product highlights
• 1.5 V and 9 V battery test
Manual
Range
CAT III
600 V
Included:
1 x AM-500-EUR
2 x test leads
2 x battery 1.5 V, LR3
1 x user manual
battery test
Accessories:
Carrying case for devices with protective holster Model 1150
Safety set
Model 370003
Technical specifications
Display
LCD, 3½ digit, 1999 digits
Ranges
Resistance
0,01 Ω...20 MΩ
Basic accuracy
±(0.5% rdg + 5 digits)
Continuity
R < 30 Ω
Inductance
1 μH...200 H
Basic accuracy
±(3.0% rdg. + 20 digits)
Capacitance
1 pF...2000 μF
Basic accuracy
±(1.0% rdg. + 3 digits)
Diode test
0…3 V
Accuracy
±(1.5% rdg. +1 digit)
Transistor test (NPN, PNP) hfe, Iceo
Test current:
approx. 1 mA
Test voltage:
3.0 V DC typical
Power supply
1 x battery 9 V, IEC 6LR61
Dimensions
183 x 79 x 38 mm
Weight
approx. 311 g (incl. battery)
Ordering Information:
Description
Model
LCR55A
LCR55A
CC-ACDC
CC-ACDC
Article no.
3026976
2732643
Technical specifications
Display
LCD, 3½ digit, 1999 digits
Ranges
AC voltage
1 mV...600 V
Basic accuracy
±(1.0% rdg. + 3 digits)
Frequency range
45...400 Hz
DC voltage
1 mV...600 V
Basic accuracy
±(0.8% rdg. + 3 digits)
Input resistance
10 MΩ
AC current
0.1 μA...10 A
Basic accuracy
±(1.5% rdg. + 3 digits)
Frequency range
45...400 Hz
DC current
0.1 μA...10 A
Basic accuracy
±(1.2% rdg. + 3 digits)
Resistance
1 Ω...20 MΩ
Basic accuracy
±(1.5% rdg. + 5 digits)
Pollution degree
2
Measurement category CAT III/600V
Safety cert.:
DIN VDE 0411, EN 61010,
IEC 61010
Power supply
2 x 1.5 V, LR3
Dimensions
150 x 83 x 40 mm
Weight
290 g (incl. battery)
Ordering Information:
Description
Model
AM-500-EUR
Carrying case
Safety set
AM-500-EUR
1150
370003
Article no.
4102332
2145755
2146666
27
Digital Multimeter | Multimeter
AM-510-EUR
Technical specifications*
Functions
Display
Ranges
AC voltage
Basic accuracy
Frequency range
DC voltage
Basic accuracy
Input resistance
AC current
Basic accuracy
Frequency range
DC current
Basic accuracy
Resistance
Basic accuracy
Continuity
Frequency
Basic accuracy
Capacitance
Basic accuracy
Temperature
Basic accuracy
Pollution degree
Measurement category
• Voltage, current and resistance measurement
• Capacitance and frequency measurement
• Diode and acoustic continuity test
• Battery test 1.5 V and 9 V (AM-510-EUR only)
Product information
• Automatic and manual range selection
• Integrated measurement memory (data hold)
• Illuminated display
• Relative measurement
• Auto Power Off
Product highlights
Auto/
Manual
Range
CAT III
600 V
• True RMS measurement (TRMS)
(only AM-530-EUR and AM-550-EUR)
• Non-contact voltage detection
• Built-in LED flashlight
Hz
AM-520-EUR
Data
Hold
As AM-510-EUR, but with:
Bargraph
• Temperature measurement
Product information
• Additional bar graph display (61 segments)
• MIN/MAX hold
• Carry case included
Included with AM series:
1x
2x
1x
2x
1x
1x
1x
1x
Safety cert.
AM-510-EUR, AM-520-EUR, AM-530-EUR,
AM-535-EUR, AM-540-EUR, AM-550-EUR,
AM-555-EUR
test leads
temperature probe (only AM-520-EUR,
AM-530-EUR
As AM-520-EUR, but with:
* Technical data relates to the highest model in the
series. Data regarding individual modules can be
found on our website www.beha-amprobe.com.
AM-540-EUR
As AM-520-EUR, but with:
• Low pass filter
• Peak value measurement
Product highlights
battery 9 V, IEC 6LR61
carry case (only AM-520-EUR, AM-530-EUR,
user manual
Accessories:
• Two temperature inputs
• Duty cycle function
• Measurement category CAT IV / 600V, CAT III /
1000V
Ordering Information:
Description
Safety set
Model 370003
VC221B carrying case
Material: Imitation leather, carrying strap
External dimensions: 220 x 115 x 60 mm
Model VC221B
Display
True-RMS
measurement
AM-510-EUR
AM-520-EUR
Model
Article no.
AM-550-EUR
AM-510-EUR
AM-510-EUR
As AM-540-EUR, but with:
AM-520-EUR
AM-520-EUR
AM-530-EUR
AM-530-EUR
• True RMS measurement (TRMS)
2 x temperature probes with adapter
For AM-540-EUR and AM-550-EUR,
AM-555-EUR
Model TPK-62
Model
1 mV...1000 V
±(1.0% rdg. + 3 digits)
45 Hz...1 kHz
0.1 mV...1000 V
±(0.5% rdg. + 3 digits)
10 MΩ
0.1 μA...10 A
±(1.2% rdg. + 5 digits)
45 Hz...1 kHz
0.1 μA...10 A
±(1.0% rdg. + 2 digits)
0.1 Ω...60 MΩ
±(1.0 % rdg. + 2 digits)
R < 10 Ω
1.00 Hz...60 MHz
±(0.1% rdg. + 3 digits)
0.01 nF...60 mF
±(3.0% rdg. + 5 digits)
-40°C...1000°C
±(1.0% rdg. + 8 °C)
2
CAT III/600 V, CAT II/1000 V
(AM-510, AM-520, AM-530)
CAT IV / 600 V, CAT III / 1000 V
(AM-540, AM-550)
DIN VDE 0411, EN 61010,
IEC 61010
1 x battery 9 V, IEC 6LR61
182 x 90 x 45 mm
• True RMS measurement (TRMS)
AM-530-EUR, AM-535-EUR)
temperature probes (only AM-520-EUR,
AM-530-EUR, AM-535-EUR)
temperature adapter (only AM-535-EUR,
AM-540-EUR, AM-550-EUR, AM-555-EUR)
hanging strap (only AM-520-EUR, AM-530-EUR,
AM-540-EUR, AM-550-EUR)
AM-535-EUR, AM-540-EUR, AM-550-EUR, AM-555-EUR)
1x
Power supply
Dimensions
LCD, 33/4 digit, 5999 digits
AM-530-EUR
AM-535-EUR
AM-535-EUR
AM-535-EUR
AM-540-EUR
AM-540-EUR
AM-550-EUR
AM-550-EUR
AM-555-EUR
AM-555-EUR
Safety set
370003
AM-540-EUR
AM-550-EUR
4102344
4131281
4131296
4701027
4131308
4131313
4701030
2146666
AM-555-EUR
33/4 digit, 3999 digits 33/4 digit, 3999 digits 33/4 digit, 3999 digits 33/4 digit, 3999 digits 33/4 digit, 5999 digits 33/4 digit, 5999 digits 33/4 digit, 5999 digits
–
–
•
•
–
•
•
Bar graph
–
•
•
•
•
•
•
Temperature
–
•
•
•
•
•
•
Temperature
inputs
0
1
1
1
2
2
2
Min/max value
memory
–
•
•
•
•
•
•
Peak Hold
–
–
–
–
•
•
•
Battery test
•
–
–
–
–
–
–
Low pass filter
–
–
–
–
•
•
•
Duty cycle
function
–
–
–
–
•
•
•
CAT III / 600 V
CAT III / 600 V
CAT II / 1000 V
CAT III / 600 V
CAT II / 1000 V
CAT III / 600 V
CAT II / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
CAT IV / 600 V
CAT III / 1000 V
Measurement
Category
28
Multimeter
Hexagon® 110
Technical specifications*
Digital multimeter with
extra large display
Functions
• Voltage, current and resistance measurement
• Capacitance and frequency measurement
• Diode and acoustic continuity test
Hexagon 110
Product information
• Automatic and manual range selection
• Integrated measurement memory (Data Hold)
and Max Hold
• Relative measurement
• Auto Power Off
• Shock-proof and impact-resistant thanks to
standard protective holster
Product highlights
• Digital multimeter with extra large display
• Acoustic warning signal and display message in
case of incorrect jack connections (Hexagon 110
and 120 only)
Hexagon® 120
As Hexagon 110, but with:
Hexagon 340
Hexagon 120
• Temperature measurement
Auto/
Manual
Range
Data
Hold
Hz
PC
Hexagon® 340A
As Hexagon 120, but with:
• True RMS measurement (TRMS)
• Electrically isolated IR/RS-232 interface
(software with adapter as option)
• 0.08 % best level of basic accuracy
• Additional analog bar graph with zoom function for evaluating trends
• Illuminated display
1 x Hexagon 110, 120 or 340
1 x protective holster
2 x test leads
1 x temperature probe (0° C...+400° C) (120, 340)
1 x battery 9 V, IEC 6LR61 (340)
2 x battery 1.5 V, IEC LR03 (110, 120)
1 x user manual
* Technical data relates to the highest model in the
series. Data regarding individual modules can be
found on our website www.beha-amprobe.de or
pages 31 and 32.
Model
Hexagon 110
Hexagon 120
Hexagon 340A
Display
33/4 digit, 4000 digits
33/4 digit, 4000 digits
33/4 digit, 5000 digits
True-RMS measurement
–
–
•
Bar graph
–
–
•
Temperature
–
•
•
Max Hold
Max Hold
•
Peak Hold
–
–
•
Illuminated display
–
–
•
RS-232 interface
–
–
•
Acoustic jack control
•
•
–
IR/RS-232 interface
–
–
•
CAT III / 600 V
CAT III / 600 V
CAT IV / 600 V
Min/max value memory
Measurement Category
Included with Hexagon:
Display
LCD, 3¾ digit, 5000 digits
Ranges
AC/DC voltage
0.01 mV...1000 V
AC basic accuracy
± (0.5 % rdg. + 3 D)
DC basic accuracy
± (0.08 % rdg. + 2 D)
AC/DC current: 0.1 μA to 10 A (20 A, 30 s)
AC basic accuracy
± (0.6 % rdg. + 3 D)
DC basic accuracy
± (0.2 % rdg. + 4 D)
AC frequency
range
40 Hz ... 20 kHz
Alternating current
40 Hz...1 kHz
Resistance
0.01 Ω...50 MΩ
Basic accuracy
±(0.1 % rdg. + 2 D)
Temperature
-50°...1000° C
Basic accuracy
±(0.3% rdg. + 3 digits)
Frequency
5 Hz...125 kHz
Basic accuracy
±(0.01% rdg. + 2 digits)
Capacitance
0.01 nF...9999 μF
Basic accuracy
±(0.8% rdg. + 3 digits)
Pollution degree
2
Measurement category CAT III/600 V, CAT II/1000 V
(110, 120)
CAT IV/600 V, CAT III/1000 V (340)
Safety cert.
DIN VDE 0411, EN 61010,
IEC 61010
Power supply
1 x battery 9 V, IEC 6LR61
Dimensions
198 x 97 x 55 mm
Weight
approx. 430 g
Accessories:
Ordering Information:
Description
Model
Article no.
For all Hexagon models
Carrying case for devices with
protective holster
Model 1150
Safety set
Model 370003
For Hexagon 340:
Hexagon 110
93523-D
Hexagon 120
93524-D
Hexagon 340A
93497-D
Carrying case
1150
Safety set
370003
Software
1332
3454478
3454484
3454491
2145755
2146666
3313506
Software for transferring and
displaying data on a PC
Model 1332
29
Digital Multimeter | Multimeter
PM51A
Pocket multimeter with frequency
and capacitance measurement
Functions
• AC/DC voltage measurement
• Measuring resistance
• Diode and acoustic continuity test
• Capacitance and frequency measurement
Product information
• Automatic range selection
• Integrated measurement memory (data hold)
• With securely connected test leads
• Auto Power Off
Product highlights
Auto
Range
• Compact digital multimeter in card format
• Large, clear display
Data
Hold
Technical specifications
Display
Ranges
AC voltage
Basic accuracy
Frequency range
DC voltage
Basic accuracy
Input resistance
Resistance
Basic accuracy
Continuity
Frequency
Basic accuracy
Capacitance
Basic accuracy
Pollution degree
Measurement category
Safety cert.
Power supply
Dimensions
Weight
Included:
Accessories:
1 x PM51A
1 x battery 3 V, IEC CR2032
1 x user manual
Soft Field Case
Model VC30A
PM55A
Pocket multimeter with non-contact
voltage detection (VolTect™) and
automatic function selection
(AutoTect™)
Functions
• Voltage and resistance measurement
• Diode and acoustic continuity test
• Voltage measurement (AC/DC μA range)
• Capacitance and frequency measurement
• Non-contact voltage detection (VolTectTM)
Product information
Auto
Range
V
non contact
• Automatic range selection
• Includes rubber protective cover
• Auto Power Off
Product highlights
• Compact digital multimeter in card format
• Large, clear display
• Automatic function selection of voltage and
resistance (AutoTect™)
1 x PM55A
1 x battery 3 V, IEC CR2032
1 x case
1 x user manual
30
Accessories:
Soft Case
Model VC30A
0.001 V...600 V
±(2.0% rdg. + 5 digits)
50 Hz...500 Hz
0.1 mV...600 V
±(1.0% rdg. + 2 digits)
10 MΩ
0.1 Ω...40 MΩ
±(1.5 % rdg. + 6 digits)
R < 65 Ω
5 Hz...1 MHz
±(0.5% rdg. + 4 digits)
0.1 nF...3000 μF
±(3.5 % rdg. + 6 digits)
2
CAT III/300V, CAT II/600V
DIN VDE 0411, EN 61010,
IEC 61010
1 x battery 3 V, IEC CR2032
113 x 53 x 10 mm
approx. 78 g (incl. battery)
Ordering Information:
Description
Model
PM51A
PM51A
VC30A
VC30A
Article no.
2727700
3099130
Technical specifications
Display
Ranges
AC voltage
Basic accuracy
Frequency range
DC voltage
Basic accuracy
Current AC
Basic accuracy
Frequency range
Current DC
Basic accuracy
Resistance
Basic accuracy
Continuity
Frequency
Basic accuracy
Capacitance
Basic accuracy
Pollution degree
Measurement category
Safety cert.
Power supply
Dimensions
Weight
Included:
LCD, 33/4 digit, 4000 digits
LCD, 33/4 digit, 6000 digits
0.001 V...600 V
±(1.5% rdg. + 5 digits)
50 Hz…60 Hz
0.001 V...450 V
±(0.5% rdg. + 3 digits)
0.1 μA...2000 μA
±(1.5% rdg. + 3 digits)
50 Hz…60 Hz
0.1 μA...2000 μA
±(1.2% rdg. + 3 digits)
0.1 Ω...6,000 MΩ
±(1.2 % rdg. + 6 digits)
R < 175 Ω
10 Hz...30.00 kHz
±(0.5% rdg. + 4 digits)
0.1 nF...100.0 μF
±(3.5 % rdg. + 6 digits)
2
CAT III/300V, CAT II/600V
DIN VDE 0411, EN 61010,
IEC 61010
1 x battery 3 V, IEC CR2032
113 x 53 x 10 mm
approx. 78 g (incl. battery)
Ordering Information:
Description
Model
PM55A
PM55A
VC30A
VC30A
Article no.
2727721
3099130
Multimeter
HD160C
Heavy-duty digital multimeter
(TRMS)
Functions
• Voltage, current and resistance measurement
• Diode and acoustic continuity test
• Capacitance and frequency measurement
• Temperature measurement
Product information
• Automatic and manual range selection
• Integrated measurement memory (data hold)
• MIN/MAX, relative and average value measurement
• Illuminated display
• Shock-proof and impact-resistant thanks to standard protective holster
• Auto Power Off
Product highlights
Auto/
Manual
Range
CAT IV
1000 V
Data
Hold
Hz
HIGHEST
SAFETY RATING
CAT IV/1000V
Included:
1 x HD160C
2 x test leads
1 x magnetic holder
1 x temperature probe
1 x battery 9 V, IEC 6LR61
1 x user manual
• True RMS measurement (TRMS)
• Highest safety rating of CAT IV/1000 V
• High voltages (1000 V AC and 1500 V DC)
• Protection category: IP67
HD110C
Robust multimeter for
industrial applications
Technical specifications
Display
LCD, 4 digit, 9999 digits
Ranges
AC voltage
0.1 mV...1000 V
Basic accuracy
±(1.2 % rdg. + 10 digits)
Frequency range
45 Hz...2 kHz
DC voltage
0.1 mV...1500 V
Basic accuracy
±(0.1% rdg. + 5 digits)
Input resistance
10 MΩ
AC current
0.01 μA...2 A
Basic accuracy
±(0.8 % rdg. + 4 digits)
Frequency range
45 Hz...1 kHz
DC current
0.01 μA...2 A
Basic accuracy
±(1.5% rdg. + 10 digits)
Resistance
0.1 Ω...40 MΩ
Basic accuracy
±(1.0 % rdg. + 10 digits)
Continuity
R < 40 Ω
Frequency measurement 0.01 Hz...10 MHz
Basic accuracy
±(0.1% rdg. + 5 digits)
Capacitance measurement 0.01 nF...400.0 μF
Basic accuracy
±(3.0% rdg. + 10 digits)
Temperature
-20°C...1300°C
Basic accuracy
±(1.0% rdg. + 3 °C)
Pollution degree
2
Measurement category CAT IV / 1000 V
Safety cert.
DIN VDE 0411, EN 61010, IEC 61010
Power supply
1 x battery 9 V, IEC 6LR61
Dimensions
200 x 102 x59 mm
Weight
approx. 642 g (incl. battery)
Functions
• Voltage, current and resistance measurement
• Diode and acoustic continuity test
Product information
Professional test lead set with silicone insulation
• Manual range selection
• Integrated measurement memory (data hold)
• Shock-proof and impact-resistant thanks to standard protective holster
• Auto Power Off
Model 1306
Product highlights
Accessories:
* Technical data relates to the HD160C model. Data
regarding individual models can be found on our
website www.beha-amprobe.com
Ordering Information:
Description
Model
HD160C
HD160C
• Highest safety rating of CAT IV/1000 V
• High voltages (1000 V AC and 1500 V DC)
• Protection category: IP67
HD110C
HD110C
DM73C
Technical specifications
Pen Type Digital Multimeter
Functions
• Voltage and resistance measurement
• Diode and acoustic continuity test
Product information
• Automatic range selection
• Integrated measurement memory (data hold)
• Additional bar graph display
• Auto Power Off
Product highlights
• Compact multimeter in pen design
Professional test lead set 1306
Display
Ranges
AC voltage
Basic accuracy
Frequency range
DC voltage
Basic accuracy
Input resistance
Resistance
Basic accuracy
Continuity
Pollution degree
Measurement category
Safety cert.
Power supply
Dimensions
Weight
Auto
Range
CAT II
600 V
Included:
1 x DM73C
1 x test leads
1 x crocodile clip
1 x probe
2 x battery 1.5 V, IEC LR44
1 x user manual
Bargraph
Article no.
2670787
2670779
3313458
LCD, 33/4 digit, 3400 digits
0.001 V...600 V
±(1.5% rdg. + 8 digits)
50 Hz...500 Hz
0.1 mV...600 V
±(0.5% rdg. + 2 digits)
10 MΩ
0.1 Ω...34 MΩ
±(1.0 % rdg. + 4 digits)
R < 35 Ω
2
CAT III/300V, CAT II/600V
DIN VDE 0411, EN 61010,
IEC 61010
2 x battery 1.5 V, IEC LR44
198 x 29 x 35 mm
approx. 150 g (incl. battery)
Data
Hold
Accessories:
Carrying case
Model VC30A
Ordering Information:
Description
Model
DM73C
DM73C
VC30A
VC30A
Article no.
2727739
3068280
31
Digital multimeters | Junior set and kits
Our recommendation for training!
Junior set A
consisting of:
• Hexagon 60 digital multimeter
• 2100-ALPHA
• Testfix 9023
• Test leads (red/black)
• Rugged carrying case
Included:
Ordering Information:
1 x Hexagon 60
1 x 2100-ALPHA
1 x Testfix 9023
2 x test leads
1 x robust carry case
Description
Model
Junior set A
AMPRB-EU-03-A
Article no.
4460579
AMPRB-EU-01-A
Standard kit
Contents
• AM-510-EUR (Digital multimeter)
• ACD-10 PLUS (Digital current clamp)
• TPP1-C1 (contact thermometer)
• EU-200 (test lead set with 2 leads), 2 test prods
(4 mm), 2 crocodile clips (CAT III/1000 V)
• Hard carrying case
Included:
Ordering Information:
1 x AM-510
1 x ACD-10 PLUS
1 x TPP1-C1
1 x EU-200
1 x Hard carrying case
Description
Model
Standard kit A
AMPRB-EU-01-A
Article no.
4460593
AMPRB-EU-02-A
Professional kit
Contents
• AM-540-EUR (Digital multimeter)
• ACDC-100 TRMS (digital AC/DC current clamp)
• IR608A infrared thermometer
• EU-200 (test lead set with 2 leads), 2 test prods
(4 mm), 2 crocodile clips CAT III/1000 V
• Hard carrying case
Included:
1 x AM-540-EUR
1 x ACDC-100 TRMS
1 x IR608A
1 x EU-200
1 x Hard carrying case
32
Ordering Information:
Description
Model
Article no.
Professional kit A
AMPRB-EU-02-A 4460587
Current clamps
Our clamp meters and clamp adapters
are suitable for measuring currents
without interruption of the current flow.
They enable current measurements
in units and systems from 1 mA up to
3000 A.
Our leakage current clamps, which
enable a resolution of 0.01 mA AC, are
ideal for troubleshooting insulation
faults in systems and in equipment tests.
Products
Symbols used in this chapter
PC
Minimal or maximal value memory
Peak
Hold
1000 A
AC/DC
Output
Analog
35
Clamp meters (AC)
40
Clamp meters (AC/DC)
41
Power clamp meters
44
Leakage current clamp meters
46
Clamp meters (AC/DC),
current clamp adapters,
and accessories
47
Setting up UNINSULATED, HAZARDOUS, ACTIVE
conductors and removal of these is permitted
data
logger
Integrated measurement value recording (data logger)
Information regarding the current measurement range
(e.g. 1000 A AC)
Back light
Analog output
True-RMS measurement
Temperature measurement
38
PC interface
Peak value memory
Best resolution (e.g. 10 μA AC)
Full overview
AMP series of clamp meters
(AC, AC/DC)
CAT IV
600 V
L3
Measurement Category
L1
Low pass filter
Phase sequence indication
L2
Capacitance measurement
Measuring resistance
0…2 k
Hz
Frequency verification
Measurement of ionization current (uA DC range) in heating systems
Acoustic continuity measurement (occasionally with diode
test)
AMP tip
33
Current clamps | Things to know about current clamps
Interesting facts regarding
current clamps and clamp
adapters
conductor (e.g. N) can be quickly, simply,
and safely measured by covering all
active conductors (e.g. L1, L2, L3, N, or
L1, N).
Current clamps and clamp adapters
are suitable for measuring AC and DC
currents on units and systems without
interrupting the current flow.
Leakage
current
0,5 mA
Earth
ground
(e.g. via
motor shaft)
Measurements with "Max-Hold" function
Readout Clamp with activated
"MAX-HOLD" function
True-RMS measurement is necessary
for the most precise recording of an
alternating or mixed current.
Differential current measurement
with leakage current clamp
Our current clamps and clamp adapters
are characterized by being simple and
intuitive. The individual conductor is fully
surrounded by the current clamp. The
measured value appears on the digital
display and can be read off immediately.
Measurement of current usage
"Max-Hold" function of a
single-phase motor
Stray current measurement
(leakage current measurement)
H igh- r e so lu tio n c urrent clamps
for leakage currents over 10 μA
are indispensable, particularly for
troubleshooting or for testing units
and systems in accordance with the
Ordinance on Industrial Safety and
Health (DGUV Regulation 3). Currents
that do not flow back via an electrical
34
Time
True-RMS measurement
Simple to use
Earth ground
Electricity
Leakage
current
1,2 mA
Measuring current without
interruptions
Switching off systems or individual
units in order to separate the circuit is
not generally possible in practice and is
largely avoided. All hazards, such as, for
example, the appearance of hazardous
contact voltages or a potential polarity
reversal upon closing the circuit can be
effectively prevented.
Some clamp meters are equipped with
a peak value memory (or measurement
of inrush current). Due to the shorter
response time it is possible to record
current spikes in motors upon ignition,
for example.
Display: 1.7 mA
Safety
Only use current clamps or clamp
adapters that are suitable for the stated
measurement category for the desired
measurement. If, for example, you
wish to carry out a measurement in a
distribution cabinet within a building,
then a multimeter with at least a
measurement category of III (CAT III)
must be used. A detailed description
of the measurement categories can be
found on page 106.
Peak value memory (Peak Hold)
Storing the displayed reading
(Hold) and measurement
memory
After pressing the HOLD button, the
value that is currently displayed is
stored on the display. This is very useful
if the display cannot be read during
measurement. With some current clamps
the minimum or maximum value (min/
max data hold) of a measurement series
can also be stored on the display.
The effective value plays an important
part, especially with non-sinusoidal
currents, e.g. phase angle control. The
average value displayed by traditional
current clamps is lower than the current
that is actually available. Further
information regarding the effective
value can be found in "Things to know
about multimeters".
Power clamp meters
Measurement of apparent, active,
reactive power and power factor cos
is quick and simple with the BEHAAMPROBE range of power clamp meters.
Power consumers with load currents up
to 1000 A can be measured.
Clamp adapters
Clamp adapters are suitable for
applications which are solely aimed at
recording measurements. Depending
on the type of evaluating circuit, the
primary flowing current can be converted
into a considerably lower, safe secondary
current or a voltage. Applications: e.g.
switch cabinet construction, laboratory
measurement circuits.
•
60.00 / 300.0 A
1.5% + 5 counts
Current DC
Basic Accuracy*
R < 10 Ω
•
MIN/MAX/Peak Hold
Features
Measurement category
CAT III/600V
Diode test,
Back light
Back light
Low pass filter
Non-contact voltage recognition, measurement of inrush
current
•
2 x 1.5 V IEC LR03
30 mm
•
•
•
CAT III/600V
•
Power supply
Auto Power Off
25 mm
2 x 1.5 V IEC LR44
Jaw opening
Capacitance measurement
•
Data Hold
Power measurement
5.00 Hz…999.9 Hz
Continuity test
Frequency verification
1% + 5 counts
Basic Accuracy*
Diode test,
Back light
CAT III/600V
•
2 x 1.5 V IEC LR03
35 mm
•
•
•
5.00 Hz…999.9 Hz
R < 10 Ω
1% + 5 counts
0.1 Ω…60,00 kΩ
0.1 Ω…60,00 kΩ
Resistance
0.1…600.0 V
50…60 Hz
1.0% + 5 counts
0.1…600.0 V
2.0 % + 5 counts
60.00 / 600 A
50…400 Hz
2.2 % + 7 counts
60.00 / 600.0 A
3 ¾ digit,
6000 digits
•
AC/DC
600 A
AMP-220-EUR
1.2% + 7 counts
50…60 Hz
1.0% + 5 counts
0.1…600.0 V
50…400 Hz
2.2 % + 7 counts
60.00 / 600.0 A
3 ¾ digit,
6000 digits
•
AC
600 A
AMP-210-EUR
Basic Accuracy*
Voltage DC
Frequency
Basic accuracy*
Voltage AC
50…400 Hz
1.5% + 5 counts
Basic Accuracy*
Frequency
60.00 / 300.0 A
3 ¾ digit,
6000 digits
Current AC
Display
True RMS measurement
300 A
AC/DC
Current type
AMP-25-EUR
Max. current
Model
Diode test, back light thermometer -40°C to 400°C
3-phase and motor rotation
indicator
DC micro amps
CAT III/600V
•
2 x 1.5 V IEC LR03
30 mm
•
•
•
5.00 Hz…999.9 Hz
R < 10 Ω
1% + 5 counts
0.1 Ω…60,00 kΩ
50…60 Hz
1.0% + 5 counts
0.1…600.0 V
50…400 Hz
2.2 % + 7 counts
60.00 / 600.0 A
3 ¾ digit,
6000 digits
•
AC
600 A
AMP-310-EUR
Diode test,
Back light
Thermometer -40°C to 400°C
3-phase and motor rotation
indicator
DC micro amps
CAT III/600V
•
2 x 1.5 V IEC LR03
35 mm
•
•
•
5.00 Hz…999.9 Hz
R < 10 Ω
1% + 5 counts
0.1 Ω…60,00 kΩ
1.2% + 7 counts
0.1…600.0 V
50…60 Hz
1.0% + 5 counts
0.1…600.0 V
2.0 % + 5 counts
60.00 / 600 A
50…400 Hz
2.2 % + 7 counts
60.00 / 600.0 A
3 ¾ digit,
6000 digits
•
AC/DC
600 A
AMP-320-EUR
Diode test, back light thermometer -40°C to 400°C
3-phase and motor rotation
indicator
DC micro amps
Flashlight function
CAT IV 600V, III 1000V
•
2 x 1.5 V IEC LR6
51 mm
•
•
•
5.00 Hz…999.9 Hz
R < 10 Ω
1% + 5 counts
0.1 Ω…60,00 kΩ
0.8% + 5 counts
0.1…1000 V
20…400 Hz
0.8% + 5 counts
0.1…1000 V
1.8% + 5 counts
60.00 / 1000 A
40…400 Hz
1.8% + 5 counts
60.00 / 1000 A
3 ¾ digit,
6000 digits
•
AC/DC
1000 A
AMP-330-EUR
Overview
* = Basic accuracy figures are with regard to the best level of accuracy of the relevant measurement function
35
36
R < 120 Ω
Features
Narrow jaws
Measurement of
inrush current
2000 μA measurement
range for
direct measurement of
ionization currents in
heating systems
CATIII/600 V
•
CATIII/600 V
•
Measurement Category
Auto Power Off
2 x 3 V,
IEC/CR2032
1 x 3V,
IEC/CR2032
•
26 mm
Power supply
•
25 mm
Capacitance measurement
•
•
0.001Hz...100kHz
R < 120 Ω
0.8% + 6 digits
0.1 Ω... 40.00 MΩΩ
Jaw opening
•
•
Data Hold
MIN/MAX/Peak Hold
Power measurement
0.001Hz...100kHz
Continuity test
Frequency verification
1.0% + 4 digits
0.1 Ω...40.00 MΩΩ
Basic Accuracy*
Resistance
0.1 V... 600 V
0.1 mV... 600 V
0.5 % + 3 digits
Voltage DC
Basic Accuracy*
0.5 % + 3 digits
50...400 Hz
50...500 Hz
Frequency
1 mV... 600 V
1 mV... 600 V
CATIII/600 V
Non-contact voltage
recognition, swivel
clamp head (180°)
Non-contact voltage
recognition, swivel
clamp head (180°)
•
2 x 1.5 V,
IEC LR03
30 mm
•
•
R < 25 Ω
1.0% + 4 digits
0.1Ω...40.00 MΩΩ
0.5 % + 2 digits
0.1 mV... 600 V
50...500 Hz
1.2% + 5 digits
CATIII/600 V
•
2 x 1.5 V,
IEC LR03
30 mm
•
R < 25 Ω
1.0% + 4 digits
0.1Ω...40.00 MΩΩ
0.5 % + 2 digits
0.1 mV... 600 V
50...500 Hz
1.2% + 5 digits
CATII/600 V
2 x 1.5 V,
IEC LR6
23 mm
•
•
0.01 Hz…50 kHz
R < 40 ΩΩ
2% + 2 digits
0.1 Ω…400 Ω
2% + +2
0.1 V...400 V
40Hz...1kHz
2% + +2
0.1 V...400 V
1.5% + 5 digits
1.5% + 5 digits
Basic Accuracy*
0.001 V... 600 V
0.001 V... 600 V
Voltage AC
40Hz...1kHz
2% + 4 digits
0.01A...200 A
3¾ digit,
3999 digits
AC/DC
200 A
CHB 15
2% + 2 digits
50/60 Hz
2% + 6 digits
0.01 A... 400 A
3¾ digit,
3999 digits
•
AC
400 A
ACD-23SW
0.01 A...200 A
50/60 Hz
2% + 6 digits
0.01 A... 400 A
3¾ digit,
3999 digits
AC
400 A
ACD-20SW
Basic Accuracy*
50/60 Hz
1.9% + 8 digits
0.01 A... 600 A
3¾ digit,
4000 digits
AC
600 A
ACD-14-PRO-EUR
Current DC
50/60 Hz
1.5% + 8 digits
Basic Accuracy*
Frequency
0.01 A... 600 A
Current AC
Display
3¾ digit,
4000 digits
AC
True RMS measurement
600 A
Current type
ACD-10 PLUS
Max. current
Model
Non-contact
frequency measurement
CATII/600 V
2 x 1.5 V,
IEC LR6
23 mm
•
•
0.01 Hz...9.99 kHz
2% + 2 digits
0.01 A...400 A
40Hz...1kHz
2% + 3 digits
0.001 A...400 A
3¾ digit,
3999 digits
•
AC/DC
400 A
CHB 35
Measurement of inrush
current
CATIII/600 V
•
2 x 1.5 V,
IEC LR03
50 mm
R < 120 Ω
R < 120 Ω
0.8% + 6 digits
0.1 Ω…40 MΩ
0.5 % + 3 digits
0.1 mV...600 V
50...500 Hz
1% + 4 digits
0.1 mV...600 V
1.5% + 4 digits
0.1 A...1000 A
40...200 Hz
1.5% + 5 digits
0.1 A...800 A
3¾ digit,
4000 digits
AC/DC
800 A AC/1000 A DC
ACDC-100
Measurement of inrush
current
True-rms reading
CATIII/600 V
•
2 x 1.5 V,
IEC R03
50 mm
•
R < 120 Ω
R < 120 Ω
0.8% + 6 digits
0.1 Ω…40 MΩ
0.5 % + 3 digits
0.1 mV...600 V
50...500 Hz
1% + 4 digits
0.1 mV...600 V
1.5% + 4 digits
0.1 A...1000 A
40...200 Hz
1.5% + 5 digits
0.1 A...800 A
3¾ digit,
4000 digits
•
AC/DC
800 A AC/1000 A DC
ACDC-100 TRMS
Current clamps | Overview
50 Hz…400 Hz
Frequency
Features
Active power,
cos ,
Harmonic content (THD),
Bar graph
•
CAT IV / 600 V
CAT III / 1000 V
Measurement Category
Active power,
cos ,
Harmonic content (THD),
Bar graph
•
CAT IV / 600 V
CAT III / 1000 V
9 V, IEC 6F22
Power supply
Auto Power Off
9 V, IEC 6F22
37 mm
42 mm
0.01…4000 μF
0.01…4000 μF
Jaw opening
Capacitance measurement
•
•
MIN/MAX Peak Hold
•
•
0…600 kW
20.00…9,999 kHz
R < 30 Ω
1 % + 3 digits
1 Ω…99.99 kΩ
0.7 % + 2 digits
0.01…1000 V
50 Hz…500 Hz
1 % + 5 digits
0.01…1000 V
1.5 % + 5 digits
0.01...600 A
50 Hz…400 Hz
1.5 % + 5 digits
Data Hold
0…600 kW
R < 30 Ω
Continuity test
20.00…9,999 kHz
1 % + 3 digits
Basic Accuracy*
Frequency verification
1 Ω…99.99 kΩ
Resistance
Power measurement
0.7 % + 2 digits
0.01…1000 V
Voltage DC
Basic Accuracy*
1 % + 5 digits
50 Hz…500 Hz
Basic Accuracy*
Frequency
0.01…1000 V
Voltage AC
Basic Accuracy*
Current DC
1.5 % + 5 digits
Basic Accuracy*
Current AC
Display
•
3¾ digit,
4000 digits
0.01…1000 A
•
3¾ digit,
4000 digits
0.01…600A
•
3¾ digit,
4000 digits
0.01…600 A
Active power,
cos ,
Harmonic content (THD),
Temperature,
Bar graph
•
CAT IV / 600 V
CAT III / 1000 V
9 V, IEC 6F22
42 mm
0.01…4000 μF
•
•
0…999 kW
20.00…9,999 kHz
R < 30 Ω
1 % + 3 digits
1 Ω…99.99 kΩ
0.7 % + 2 digits
0.01…1000 V
50 Hz…500 Hz
1 % + 5 digits
0.01…1000 V
1.5 % + 5 digits
0.01…1000 A
50 Hz…400 Hz
1.5 % + 5 digits
AC/DC
1000 A AC/DC
True RMS
Measurement
600 A
AC/DC
AC
ACDC-54NAV
600 A
ACDC-52NAV
Current type
ACD-50NAV
Max. current
Model
0.1 Ω…66.00 MΩ
1% + 5 digits
R < 30 Ω
0.1 Ω…40 MΩΩ
1% + 3 digits
R < 40 Ω Ω
Illuminated
display
Relative value measurement, Illuminated display, Duty cycle function
•
CATIII/1000 V, CATIV/600 V
•
CATIII/600 V
Leakage current clamp,
lowest resolution
0.01 mA
CATII/600 V
•
30 mm
2 x 1.5 V, IEC LR6
51 mm
1 x 9 V,
IEC 6F22
2 x 1.5 V, IEC R03
•
•
R < 40 Ω
1 % + 2 digits
0.1 Ω...400 Ω
40 Hz...1 kHz
2% + 4 digits
0.1 V...400 V
40 Hz…1 kHz
1.5% + 5 digits
3¾ digit,
3999 digits
0.01 mA...60 A
AC
60 A
AC50A
30 mm
0.001 nF…6.6 mF
•
•
•
•
0.01 Hz…1000 MHz
0.5% + 2 digits
0.1 mV…1000 V
50 Hz…1 kHz
1.5 % + 8 digits
0.1 mV…750 V
2 % + 5 digits
0.1 A…1000 A
50…1 kHz
2 % + 10 digits
3¾ digit,
6600 digits
0.1 A…1000 A
•
AC/DC
1000 A
ACDC-3400 IND
0.8 % + 2 digits
0.1 mV...600 V
50...500 Hz
1% + 3 digits
0.1 mV...600 V
1.5% + 3 digits
0.01 A...400 A
50/60 Hz
1.5% + 3 digits
3¾ digit,
3999 digits
0.01 A... 400 A
AC/DC
400 A
ACDC-400
Leakage current clamp,
lowest resolution 0.01 mA
Harmonics measurement
up to the 99th peak value
measurement
CATII/600V,
CAT III/300 V
2 x 1.5 V, IEC LR6
30 mm
•
•
45 Hz...65 Hz
50 Hz...1 kHz
0.5% + 5 digits
0.1 V...600 V
45 Hz.. 1 kHz
1.5% + 5 digits
4 digit,
9999 digits
0.5 mA...50 A
•
AC
50 A
CHB 5
Measurement
of direct currents with
1 mA resolution
CATIII/300 V
•
1 x 9 V, IEC 6LR61
19 mm
•
1.3% + 5 digits
0.001...40 A
40...400 Hz
1.3% + 5 digits
4 digit,
4000 digits
0.001...40 A
AC/DC
40 A
LH41A
Overview
* = Basic accuracy figures are with regard to the best level of accuracy of the relevant measurement function
37
Current clamps
AMP-25-EUR
Technical specifications
Mini current clamp (AC/DC)
Display
Ranges
Current AC
Basic accuracy
Frequency range
Current DC
Basic accuracy
Current AC
(with low pass filter)
Basic accuracy
Frequency range
Pollution degree
Measurement category
Safety cert.:
Jaw opening
Power supply
Dimensions
Weight
Functions
• True RMS current measurement
• Low pass filter
• Measurement of inrush current
• Non-contact voltage detection
Product information
• Automatic range selection
• Zero adjustment
• Integrated measurement memory (data hold)
• Jaw opening 25 mm
• Auto Power Off
Product highlights
• Very compact design
• Illuminated display
Peak
Hold
300 A
AC/DC
Hz
CAT III
600 V
Included:
AMP-25-EUR
AMP-25-EUR
AMP-210-EUR
Technical specifications*
Product information
Hz
• Automatic range selection
• Zero adjustment, relative value measurement
• Integrated measurement memory
(Data Hold, MIN/MAX)
• Jaw opening
30 mm (AMP-210-EUR),
35 mm (AMP-220-EUR)
• Auto Power Off
Product highlights
• Precise measurement of smaller currents (AmpTip)
• Illuminated display
AMP-220-EUR
Current clamp (AC/DC)
As AM-210-EUR, but with:
• DC Current Function
• Display of mixed currents AC+DC (TRMS)
• Display of mixed voltages AC+DC (TRMS)
• Larger housing than AMP-220-EUR
600 A
AC/DC
Hz
600 V
AC/DC
CAT III
600 V
60kΩ
Included:
1 x AMP-210-EUR or AMP-220-EUR
2 x test leads
2 x batteries 1.5 V, IEC LR 03
1 x carrying case
1 x user manual
Accessories:
Safety set
Model 370003
38
Ordering Information:
Model
• Current, voltage and resistance measurement
• Capacitance and frequency measurement
• Continuity beeper
• Low pass filter
• Measurement of inrush current
• Non-contact voltage detection
CAT III
600 V
0.01 A... 300 A
±(3.5% rdg. + 5 digits)
50...60 Hz
2
CAT III/600 V
DIN VDE 0411/EN 61010/
approx. 25 mm
2x battery 1.5V IEC LR 44
147 x 60 x 32 mm
approx. 140 g
Description
Functions
600 V
AC
0.01 A... 60 / 300 A
±(1.5% rdg. + 5 digits)
50...400 Hz
0.01 A... 60 / 300 A
±(1.5% rdg. + 8 digits)
1 x AMP-25
2 x batteries 1.5V, IEC LR 44
1 x carrying case
1 x user manual
current clamp (AC)
60kΩ
LCD, 3¾ digit, 6000 digits
Article no.
4588268
Display
LCD, 3¾ digit, 6000 digits
Ranges
Current AC
0.01 A... 600 A
Basic accuracy
±(1.8% rdg. + 5 digits)
Frequency range
50...400 Hz
Current DC
0.01 A... 600 A
Basic accuracy
±(2.0% rdg. + 5 digits)
Current (Amp-Tip) AC/DC 0.01 A... 60 A
Basic accuracy
±(1.5% rdg. + 5 digits)
Frequency range
DC, 50...60 Hz
AC/DC voltage
0.1 V...600 V
Basic accuracy
±(1.0% rdg. + 5 digits)
Frequency range
DC, 50...60 Hz
Continuity
IN ≤ 10 Ω, OUT ≥ 250 Ω
Resistance
0.01 ... 60.00 kΩ
Basic accuracy
±(1.0% rdg. + 5 digits)
Capacitance
measurement
0.1 ... 2500 μF
Frequency measurement 5.00 ... 999.9 Hz
Non-Contact
Voltage measurement 10 ...1000 V AC, 50/60Hz
Pollution degree
2
Measurement category CAT III/600 V
Safety cert.:
DIN VDE 0411/EN 61010
Jaw opening
approx. 30 mm (AMP-210-EUR),
approx. 35 mm (AMP-220-EUR)
Power supply
2x batteries 1.5 V, IEC LR 03 (AAA),
Micro
Dimensions
219 x 77 x 37 mm (AMP-210-EUR),
224 x 77x 37 mm (AMP-220-EUR)
Weight
approx. 208 g (AMP-210-EUR),
approx. 254 g (AMP-220-EUR)
* Technical data relates to the highest model in the
series. Data regarding individual modules can be
found on our website www.beha-amprobe.com or
the table on pages 41, 42, and 43.
Ordering Information:
Description
Model
AMP-210-EUR
AMP-220-EUR
Safety set
AMP-210-EUR
AMP-220-EUR
370003
Article no.
4560581
4560596
2146666
Current clamps
AMP-310-EUR
current clamp (AC)
• Precise measurement of smaller currents (AmpTip)
• Displays rotary field direction and motor rotation direction Illuminated display
• Measurement of ionization current (uA DC
range) in heating systems
Display
Ranges
Current AC
Basic accuracy
Frequency range
Current DC
Basic accuracy
Current (Amp-Tip)
AC/DC
Basic accuracy
Frequency range
AC/DC voltage
Basic accuracy
Frequency range
Continuity
Resistance
Basic accuracy
Capacitance
measurement
Frequency
measurement
Non-Contact
Voltage measurement
Ionization current
Basic accuracy
Temperature
Basic accuracy
Pollution degree
Measurement category
AMP-320-EUR
Safety cert.:
Jaw opening
Functions
• Current, voltage and resistance measurement
• Capacitance and frequency measurement
• Measurement of ionization current (μA DC
range)
• Temperature measurement
• Continuity beeper
• Low pass filter
• Measurement of inrush current
• Non-contact voltage detection
Product information
Hz
600 V
AC
60kΩ
L3
L1
CAT III
600 V
L2
Technical specifications*
• Automatic range selection
• Zero adjustment, relative value measurement
• Integrated measurement memory
(Data Hold, MIN/MAX)
• Jaw opening 30 mm (AMP-310-EUR),
35 mm (AMP-320-EUR),
51 mm (AMP-330-EUR)
• Auto Power Off
Product highlights
Current clamp (AC/DC)
As AM-310-EUR, but with:
Power supply
• DC Current Function
• Display of mixed currents AC+DC (TRMS)
• Display of mixed voltages AC+DC (TRMS)
Dimensions
Weight
LCD, 3¾ digit, 6000 digits
0.01 A... 600 A (or 1000 A)
±(1.8% rdg. + 5 digits)
50...400 Hz
0.01 A... 600 A (or 1000 A)
±(2.0% rdg. + 5 digits)
0.01 A... 60 A
±(1.5% rdg. + 5 digits)
DC, 50...60 Hz
0.1 V...600 V (or 1000 V)
±(1.0% rdg. + 5 digits)
DC, 50...60 Hz
IN ≤ 10 Ω, OUT ≥ 250 Ω
0.01 ... 60.00 kΩ
±(1.0% rdg. + 5 digits)
0.1 ... 2500 μF
5.00 ... 999.9 Hz
10 ...1000 V AC, 50/60Hz
0.1 μA... 2000 μA
±(1.0% rdg. + 5 digits)
-40 ... +400 °C
±(1.0% rdg. + 0.8 °C)
2
CAT III/600 V
CAT IV / 600 V, CAT III / 1000 V
(AMP-330-EUR)
DIN VDE 0411/EN 61010
30 mm (AMP-310-EUR)
35 mm (AMP-320-EUR)
51 mm (AMP-330-EUR)
2x battery 1.5 V, IEC LR 03
( AAA), Micro
2x battery 1.5 V, IEC LR 06 (AA),
Mignon (AMP-330-EUR)
219 x 77x 37 mm (AMP-310-EUR)
224 x 77 x 37 mm (AMP-320-EUR)
258 x 94 x 44 mm (AMP-330-EUR)
approx. 208 g AMP-310-EUR),
approx. 254 g (AMP-320-EUR)
approx. 420 g (AMP-330-EUR)
Hz
0...60kΩ
L3
600 V
AC/DC
L1
* Technical data relates to the highest model in
the series. Data regarding individual modules can
be found on our website www.beha-amprobe.
com or the table on pages 41, 42, and 43.
600 A
AC/DC
CAT III
600 V
L2
AMP-330-EUR
Current clamp (AC/DC)
As AMP-320-EUR, but with:
• Voltage measurement up to 1000 A AC/DC
• AC and DC voltage measurements to 1000 V
• Measurement categories CAT IV 600 V, CAT III
1000 V
• Larger housing than AMP-320-EUR
Included:
1 x AMP-310-EUR or AMP-320-EUR
2 x test leads
2 x crocodile clips
1 x temperature probe
2 x battery 1.5 V, IEC LR 03 (or IEC LR 06)
1 x carrying case
1 x user manual
Hz
0...60kΩ
L3
L1
L2
1000 A
AC/DC
1000 V
AC/DC
CAT III
1000 V
CAT IV
1000 V
Ordering information:
Description
Model
AMP-310-EUR
AMP-320-EUR
AMP-330-EUR
Safety set
AMP-310-EUR
AMP-320-EUR
AMP-330-EUR
370003
Article no.
4560603
4560615
4560626
2146666
Accessories:
Safety set
Model 370003
39
Current clamps| Clamp meters (AC) bis 600 A
ACD-10 PLUS
current clamp (AC)
Functions
• Current, voltage and resistance measurement
• Continuity beeper
• Diode test
• Capacitance and frequency measurement
• Measurement of inrush current (30 ms)
Product information
• Automatic range selection
• Integrated measurement memory
(Data hold and MAX hold)
• Jaw opening 25 mm
• Auto Power Off
Product highlights
• Narrow jaws
Data
Hold
600 V
AC/DC
40MΩ
Hz
Peak
Hold
CAT III
600 V
Included:
Accessories:
Safety set
Model 370003
1 x ACD-10 PLUS
2 x test leads
1 x battery 3 V, IEC CR2032
1 x carrying case
1 x user manual
Current clamp
with dual display (AC)
Functions
• True RMS current measurement
• Voltage and resistance measurement
• Capacitance and frequency measurement
• Temperature measurement
• Continuity beeper
• Low pass filter
• Measurement of inrush current
• Non-contact voltage detection
Product information
• Automatic range selection
• Integrated measurement memory (data hold)
• Jaw opening 30 mm
• Auto Power Off
Hz
Data
Hold
Product highlights
• Dual display with illumination
• Precise measurement of small AC currents
(Amp-Tip)
• Measurement of ionization current
(μA DC range) in heating systems
• True RMS measurement (TRMS)
CAT III
600 V
Included:
1 x ACD-14-PRO-EUR
2 x test leads
1 x temperature probe
2 x batteries 1.5 V, IEC LR 03
1 x carrying case
1 x user manual
40
Display
LCD, 3¾ digit, 4000 digits
Ranges
Current AC
0.01 A... 600 A
Basic accuracy
±(1.5% rdg. + 8 digits)
Frequency range
50/60 Hz
AC voltage
0.001 V...600 V
Basic accuracy
±(1.5% rdg. + 5 digits)
Frequency range
50...500 Hz
DC voltage
0.1 mV...600 V
Basic accuracy
±(0.5 % rdg. + 3 digits)
Continuity
R < 120 Ω
Resistance
0.1 Ω... 40.00 MΩ
Basic accuracy
±(1.0% rdg. + 4 digits)
Frequency measurement 0.001 Hz...100 kHz
Capacitance
measurement
0.1 nF...3000 μF
Pollution degree
2
Measurement category CAT III/600 V
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Jaw opening
approx. 25 mm
Power supply
1 x battery 3 V, IEC CR2032
Dimensions
190 x 63 x 32 mm
Weight
approx. 150 g
Ordering Information:
Description
Model
ACD-10 PLUS
ACD-10 PLUS
ACD-10 PLUS
ACD-10 PLUS-D*
Safety set
370003
D* is German version
ACD-14-PRO-EUR
Peak
Hold
Technical specifications
Accessories:
Safety set
Model 370003
Article no.
3037808
3454555
2146666
Technical specifications
Display
Dual-LCD, 3¾ digit, 6000 digits
Ranges
Current AC
0.01 A... 600 A
Basic accuracy
±(1.8% rdg. + 5 digits)
Frequency range
50...400 Hz
Current (Amp-Tip) AC 0,01 A... 60 A
Basic accuracy
±(1.5% rdg. + 5 digits)
Frequency range
50...60 Hz
AC/DC voltage
0.1 V...600 V (or 1000 V)
Basic accuracy
±(1.0% rdg. + 5 digits)
Frequency range
DC, 50...60 Hz
Continuity
IN ≤ 10 Ω, OUT ≥ 250 Ω
Resistance
0.01 ... 60.00 kΩ
Basic accuracy
±(1.0% rdg. + 5 digits)
Capacitance
measurement
0.1 ... 2500 μF
Frequency measurement 5.00 ... 999.9 Hz
Non-Contact
Voltage measurement 10 ... 550 V, 50/60 Hz
Ionization current
0.1 μA... 2000 μA
Basic accuracy
±(1.0% rdg. + 5 digits)
Temperature
-40 ... +400 °C
Basic accuracy
±(1.0% rdg. + 0.8 °C)
Pollution degree
2
Measurement category CAT III/600 V
Safety cert.:
DIN VDE 0411/EN 61010
Jaw opening
30 mm
Power supply
2x batteries 1.5 V, IEC LR 03 (AAA),
Micro
Dimensions
219 x 77 x 37 mm
Weight
approx. 208 g
Ordering Information:
Description
Model
Article no.
ACD-14-PRO-EUR ACD-14-PRO-EUR
4718989
Safety set
2146666
370003
Clamp meters (AC/DC) up to 400 A / 800 A
ACD-20SW
Swivel clamp meter (AC)
Functions
• Current, voltage and resistance measurement
• Continuity beeper
• Diode test
Product information
• Automatic and manual range selection
• Integrated measurement memory (data hold)
• Jaw opening approx. 30 mm
• Auto Power Off
Product highlights
• Clamp head swivels up to 180°
• Non-contact voltage detection
600 V
AC/DC
40MΩ
CAT III
600 V
Data
Hold
Accessories:
Safety set
Model 370003
1 x ACD-20SW
2 x test leads
2 x battery 1.5V, IEC LR03
1 x carrying case
1 x user manual
ACD-23SW
Swivel clamp meter TRMS (AC)
Functions
• Current, voltage and resistance measurement
• Audible continuity and diode test
• Capacitance and temperature measurement
Product information
• Automatic and manual range selection
• Integrated measurement memory (data hold)
• Jaw opening approx. 30 mm
• Auto Power Off
Product highlights
• Clamp head swivels up to 180°
• Non-contact voltage detection
• True RMS measurement (TRMS)
40MΩ
Included:
1 x ACD-23SW
2 x test leads
2 x battery 1.5V, IEC LR03
1 x temperature probe
1 x carrying case
1 x user manual
CAT III
600 V
Display
Ranges
Current AC
Basic accuracy
Frequency range
AC voltage
Basic accuracy
Frequency range
DC voltage
Basic accuracy
Continuity
Resistance
Basic accuracy
Pollution degree
Measurement category
Safety cert.:
Jaw opening
Power supply
Dimensions
Weight
Included:
600 V
AC/DC
Technical specifications
Data
Hold
Accessories:
Safety set
Model 370003
LCD, 3¾ digit, 3999 digits
0.01...400 A
±(2% rdg. + 6 digits)
50...60 Hz
1.0 mV...600.0 V
±(1.2% rdg. + 5 digits)
50...500 Hz
0.1 mV...600 V
±(0.5% rdg. + 2 digits)
R < 25 Ω
0.1 Ω... 40 MΩ
±(1.0% rdg. + 4 digits)
2
CAT lll / 600 V
DIN VDE 0411/EN 61010/
IEC 61010
approx. 30 mm
2 x battery 1.5 V, AAA IEC LR03
240 × 70 × 41 mm
approx. 220 g
Ordering Information:
Description
Model
Article no.
ACD-20SW
ACD-20SW
3472723
Safety set
370003
2146666
Technical specifications
Display
LCD, 3¾ digit, 3999 digits
Ranges
Current AC
0.01...400 A
Basic accuracy
±(2% rdg. + 6 digits)
Frequency range
50...60 Hz
AC voltage
1.0 mV...600.0 V
Basic accuracy
±(1.2% rdg. + 5 digits)
Frequency range
50...500 Hz
DC voltage
0.1 mV...600 V
Basic accuracy
±(0.5% rdg. + 2 digits)
Continuity
R < 25 Ω
Resistance
0.1 Ω... 40 MΩ
Basic accuracy
±(1.0% rdg. + 4 digits)
Capacitance measurement
0.01…4000 μF
Temperature measurement
-35...400°C
Pollution degree
2
Measurement category CAT lll / 600 V
Safety cert.:
DIN VDE 0411/EN 61010/IEC
61010
Jaw opening
approx. 30 mm
Power supply
2 x battery 1.5 V, AAA IEC LR03
Dimensions
240 × 70 × 41 mm
Weight
approx. 220 g
Ordering Information:
Description
Model
Article no.
ACD-23SW
ACD-23SW
3804941
Safety set
370003
2146666
41
Current clamps| Clamp meters (AC/DC) bis 400 A
ACDC-400
Current clamp (AC/DC)
Functions
• Current, voltage and resistance measurement
• Continuity beeper
Product information
• Automatic and manual range selection
• Integrated measurement memory
(data hold, MIN/MAX)
• Relative measurement
• Additional bar graph display
• Jaw opening 30 mm
• Auto Power Off
Product highlights
• AC/DC clamps are also suitable for automotive
applications, emergency power supplies and
solar technology.
• Illuminated display
400 A
AC/DC
600 V
AC/DC
Auto/
Manual
Range
CAT III
600 V
Display
Ranges
Current AC
Basic accuracy
Frequency range
Current DC
Basic accuracy
AC voltage
Basic accuracy
Frequency range
DC voltage
Basic accuracy
Continuity
Resistance
Basic accuracy
Pollution degree
Measurement category
Safety cert.:
Jaw opening
Power supply
Dimensions
Weight
Bargraph
LCD, 3¾ digit, 3999 digits
0.01 A... 400 A
±(1.5% rdg. + 3 digits)
50/60 Hz
0.01 A... 400 A
±(1.5% rdg. + 3 digits)
0.1 mV...600 V
±(1% rdg. + 3 digits)
50...500 Hz
0.1 mV...600 V
±(0.8 % rdg. + 2 digits)
R < 40 Ω
0.1 Ω... 40 MΩ
±(1% rdg. + 3 digits)
2
CAT III / 600 V
DIN VDE 0411/EN 61010/
IEC 61010
approx. 30 mm
2 x battery 1.5 V, IEC LR03
205 x 64 x 39 mm
approx. 280 g
Data
Hold
Included:
1 x ACDC-400
2 x test leads
2 x battery 1.5 V, IEC LR03
1 x carrying case
1 x user manual
AMP-210-EUR AC clamp meter
42
40MΩ
Technical specifications
Accessories:
Ordering Information:
Description
Safety set
Model 370003
AMP-320-EUR AC/DC clamp meter
Model
ACDC-400
ACDC-400
Safety set
*D is German version
Article no.
ACDC-400-D* 3454596
ACD-400
2730810
370003
2146666
AMP-330-EUR AC/DC clamp meter
Current clamps (AC/DC) up to 200 A / 400 A
CHB15
Current clamp (AC/DC)
Functions
• Current, voltage and resistance measurement
• Continuity beeper
• Frequency verification
Product information
• Manual range selection
• Integrated measurement memory (data hold)
• MIN/MAX and relative value measurement
• Additional bar graph display
• Jaw opening 23 mm
Product highlights
• AC/DC clamps are also suitable for automotive
applications, emergency power supplies and
solar technology.
200 A
AC/DC
400 V
AC/DC
CAT II
600 V
Data
Hold
400Ω
Hz
Included:
Accessories:
1 x CHB15
2 x test leads
2 x battery 1.5 V, IEC LR6
1 x carrying case
1 x user manual
Safety set
Model 370003
CHB35
TRMS current clamp (AC/DC)
Functions
• Current measurement
• Frequency measurement (non-contact)
Product information
• Manual range selection
• Integrated measurement memory (data hold)
• MIN/MAX and relative value measurement
• Additional bar graph display
• Jaw opening 23 mm
Product highlights
• AC/DC clamps are also suitable for automotive
applications, emergency power supplies and
solar technology.
• True RMS measurement (TRMS)
400 A
AC/DC
CAT II
600 V
Data
Hold
Included:
1 x CHB35
2 x battery 1.5 V, IEC LR6
1 x carrying case
1 x user manual
Technical specifications
Display
LCD, 3¾ digit, 3999 digits
Ranges
Current AC
0.01...200 A
Basic accuracy
± (2 % rdg. + 4 digits)
Current DC
0.01...200 A
Basic accuracy
± (2 % rdg. + 2 digits)
Voltage AC
0.1...400 V
Basic accuracy
± (2 % rdg. + 2 digits)
DC voltage
0.1 V...400 V
Basic accuracy
± (2 % rdg. + 2 digits)
Frequency range for
AC current/voltage
40 Hz...1 kHz
Input resistance
10 MΩ
Resistance
0.1...400 Ω
Basic accuracy
± (2 % rdg. + 2 digits)
Continuity
R < 40 Ω
Frequency measurement 0.01 Hz…50 kHz
Basic accuracy
± (1 % rdg. + 2 digits)
Pollution degree
2
Measurement category CAT II/600 V
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Jaw opening
approx. 23 mm
Power supply
2 x battery 1.5 V, IEC LR6
Dimensions
183 x 64 x 36 mm
Weight
approx. 190 g
Ordering Information:
Description
Model
CHB15
93468-D
Safety set
370003
Article no.
3454457
2146666
Technical specifications
Display
LCD, 3¾ digit, 3999 digits
Ranges
Current AC
0.001...400 A
Basic accuracy
± (2 % rdg. + 3 digits)
Current DC
0.01...400 A
Basic accuracy
± (2 % rdg. + 2 digits)
AC frequency
range
40 Hz ... 1kHz
Crest factor
<4
Frequency measurement 0.01 Hz...9.99 kHz
Basic accuracy
± (1 % rdg. + 2 digits)
Pollution degree
2
Measurement category CAT II/600 V
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Jaw opening
approx. 23 mm
Power supply
2 x battery 1.5 V, IEC LR6
Dimensions
183 x 64 x 36 mm
Weight
approx. 190 g
Hz
Ordering Information:
Description
Model
CHB35
93469-D
Article no.
3454469
43
Current clamps| Clamp meters (AC/DC) bis 600 A
ACD-50NAV
CAT IV Navigator™ power clamp
meter 600 A (AC) TRMS
Functions
• Current, voltage and resistance measurement
• Continuity beeper
• Capacitance and frequency measurement
• Measurement of active power
• Measuring the power factor cos • Harmonics measurement for current and
voltage values (up to the 25th harmonic)
• Measurement of total harmonic distortion (THD)
• Measurement of inrush current for motors
Product information
CAT III
1000 V
CAT IV
600 V
1000 V
AC/DC
99kΩ
L3
Data
Hold
Bargraph
L1
L2
• Automatic and manual range selection
• Integrated measurement memory (MIN/MAX
and Data Hold)
• Peak value memory (Peak Hold)
• Rotary field measurement
• Low pass filter for measurement of
frequency converters
• Large digit display with backlit display and
analog bar graph
• Jaw opening 37 mm
• Auto Power Off
Product highlights
Hz
• AC/DC true RMS measurement (TRMS)
• Automatic flashlight function on opening the
jaws
• Non-contact voltage detection
• Functions can be selected via a joystick
Accessories:
Included:
Safety set
Model 370003
ACDC-52NAV
CAT IV Navigator™ power clamp
meter 600 A (AC/DC) TRMS
Functions
• Current, voltage and resistance measurement
• Continuity beeper
• Capacitance and frequency measurement
• Measurement of active power
• Measuring the power factor cos • Harmonics measurement for current and
voltage values (up to the 25th harmonic)
• Measurement of total harmonic distortion (THD)
• Measurement of inrush current for motors
Product information
CAT IV
600 V
600 A
AC/DC
1000 V
AC/DC
99 kΩ
L3
Data
Hold
Bargraph
L1
• Automatic and manual range selection
• Integrated measurement memory (MIN/MAX
and Data Hold)
• Peak value memory (Peak Hold)
• Rotary field measurement
• Low pass filter for measurement of frequency
converters
• Large digit display with backlit display and
analog bar graph
• Jaw opening 42 mm
• Auto Power Off
L2
Product highlights
Hz
Included:
1 x ACDC-52NAV
2 x test leads
1 x battery 9 V, IEC 6F22
1 x carrying case
1 x user manual
44
Display
LCD, 3¾ digit, 4000 digits
Ranges
Current AC
0.01…600 A
Basic accuracy
±(1.5 % rdg. + 5 digits)
Frequency range
50 Hz…400 Hz
Voltage AC
0.01...1000 V
Basic accuracy
±(1 % rdg. + 5 digits)
Frequency range
50 Hz…500 Hz
DC voltage
0.01…1000 V
Basic accuracy
±(0.7 % rdg. + 2 digits)
Active power
0…600.0 kW
cos ˻
-1.00…0.00…+1.00
Harmonics
Up to 25th
total harmonic distortion
(THD)
0,1…100 %
Resistance
1Ω…99.99 kΩ
Basic accuracy
± (1 % rdg. + 3 digits)
Continuity
R < 30 Ω
Frequency measurement 20.00…9,999 kHz
Capacitance measurement
0.01…4000 μF
Pollution degree
2
Measurement category CAT IV / 600 V, CAT III / 1000 V
Safety cert.
DIN VDE 0411/EN 61010/
IEC 61010
Jaw opening
approx. 37 mm
Power supply
1 x battery 9 V, IEC 6F22
Dimensions
approx. 260 x 80 x 40 mm
Weight
approx. 480 g
Ordering Information:
Description
1 x ACD-50NAV
2 x test leads
1 x battery 9 V, IEC 6F22
1 x carrying case
1 x user manual
CAT III
1000 V
Technical specifications
• AC/DC true RMS measurement (TRMS)
• Automatic flashlight function on opening the
jaws
• Non-contact voltage detection
• Functions can be selected via a joystick
Accessories:
ACD-50NAV
ACD-50NAV
Safety set
370003
Article no.
3729945
2146666
Technical specifications
Display
LCD, 3¾ digit, 4000 digits
Ranges
Current AC
0.01…600 A
Basic accuracy
±(1.5 % rdg. + 5 digits)
Frequency range
50 Hz…400 Hz
Current DC
0.01...600 A
Basic accuracy
±(1.5 % rdg. + 5 digits)
Voltage AC
0.01...1000 V
Basic accuracy
±(1 % rdg. + 5 digits)
Frequency range
50 Hz…500 Hz
DC voltage
0.01…1000 V
Basic accuracy
±(0.7 % rdg. + 2 digits)
Active power
0…600.0 kW
cos ˻
-1.00…0.00…+1.00
Harmonics
Up to 25th
total harmonic distortion
(THD)
0,1…100 %
Resistance
1Ω…99.99 kΩ
Basic accuracy
±(1 % rdg. + 3 digits)
Continuity
R < 30 Ω
Frequency measurement 20.00…9,999 kHz
Capacitance measurement
0.01…4000 μF
Pollution degree
2
Measurement category CAT IV / 600V, CAT III / 1000 V
Safety cert.
DIN VDE 0411/EN 61010/
IEC 61010
Jaw opening
approx. 42 mm
Power supply
1 x battery 9 V, IEC 6F22
Dimensions
approx. 260 x 80 x 40 mm
Weight
approx. 480 g
Ordering Information:
Description
Safety set
Model 370003
Model
Model
Article no.
ACDC-52NAV
ACDC-52NAV 3729961
Safety set
370003
2146666
Clamp meters (AC/DC) up to 1000 A
ACDC-54NAV
CAT IV Navigator™ power clamp
meter 1000 A (AC/DC) TRMS
Functions
• Current, voltage and resistance measurement
• Continuity beeper
• Capacitance and frequency measurement
• Temperature measurement
• Measurement of active power
• Measuring the power factor cos • Harmonics measurement for current and
voltage values (up to the 25th harmonic)
• Measurement of total harmonic distortion (THD)
• Measurement of inrush current for motors
Product information
CAT III
1000 V
1000 A
AC/DC
1000 V
AC/DC
99 kΩ
L3
Data
Hold
Bargraph
Hz
L1
L2
• Automatic and manual range selection
• Integrated measurement memory (MIN/MAX
and Data Hold)
• Peak value memory (Peak Hold)
• Rotary field measurement
• Low pass filter for measurement of frequency
converters
• Large digit display with backlit display and
analog bar graph
• Jaw opening 42 mm
• Auto Power Off
Product highlights
• AC/DC true RMS measurement (TRMS)
• Automatic flashlight function on opening the
jaws
• Non-contact voltage detection
• Functions can be selected via a joystick
Included:
Accessories:
Safety set
Model 370003
ACDC-3400 IND
CAT IV TRMS clamp meter for
industrial applications up to
1000 A (AC/DC)
Functions
• Current, voltage and resistance measurement
• Continuity beeper
• Frequency verification
• Capacitance measurement
• Peak value measurement
• Duty cycle function
Product information
CAT IV
600 V
1000 A
AC/DC
Peak
Hold
Data
Hold
Hz
Included:
1 x ACDC-3400 IND
2 x test leads
1 x battery 9 V, IEC 6F22
1 x carrying case
1 x user manual
Display
LCD, 3¾ digit, 4000 digits
Ranges
Current AC
0.01…1000 A
Basic accuracy
±(1.5 % rdg. + 5 digits)
Frequency range
50 Hz…400 Hz
Current DC
0.01...1000 A
Basic accuracy
±(1.5 % rdg. + 5 digits)
Voltage AC
0.01...1000 V
Basic accuracy
±(1 % rdg. + 5 digits)
Frequency range
50 Hz…500 Hz
DC voltage
0.01…1000 V
Basic accuracy
±(0.7 % rdg. + 2 digits)
Active power
0…999.9 kW
cos ˻
-1.00…0.00…+1.00
Harmonics
Up to 25th
total harmonic distortion
(THD)
0,1…100 %
Resistance
1Ω…99.99 kΩ
Basic accuracy
±(1 % rdg. + 3 digits)
Continuity
R < 30 Ω
Frequency measurement 20.00…9,999 kHz
Capacitance
measurement
0.01…4000 μF
Temperature
measurement
-50...1000°C
Pollution degree
2
Measurement category CAT IV / 600V, CAT III / 1000 V
Safety cert.
DIN VDE 0411/EN 61010/
IEC 61010
Jaw opening
approx. 42 mm
Power supply
1 x battery 9 V, IEC 6F22
Dimensions
approx. 260 x 80 x 40 mm
Weight
approx. 480 g
Ordering Information:
Description
1 x ACDC-54NAV
2 x test leads
1 x temperature probe
1 x battery 9 V, IEC 6F22
1 x carrying case
1 x user manual
CAT III
1000 V
Technical specifications
750 V
AC/DC
• Automatic and manual range selection
• Integrated measurement memory
(Data hold and Peak hold)
• Additional bar graph display
• Illuminated display
• Auto Power Off
• Relative measurement
• Jaw opening: 51 mm
Product highlights
• True RMS measurement (TRMS)
Accessories:
ACD-54NAV
ACD-54NAV
Safety set
370003
Test lead set with crocodile clips
Model TL36A
Article no.
3729989
2146666
Technical specifications
Display
LCD, 3¾ digit, 6600 digits
Ranges
Current AC
0.1…1000 A
Basic accuracy
± (2 % rdg. + 10 digits)
Frequency range
50 Hz…1 kHz
Current DC
0.1...1000 A
Basic accuracy
± (2 % rdg. +5 digits)
AC voltage
0.1 mV…750 V
Basic accuracy
± (1.5 % rdg. + 8 digits)
Frequency range
50 Hz…1 kHz
DC voltage
0.1 mV…1000 V
Basic accuracy
± (0.5% rdg. + 2 digits)
Continuity
R < 30 Ω
Resistance
0.1 Ω…66.00 MΩ
Basic accuracy
± (1 % rdg. +5 digits)
Frequency measurement 0.01 Hz…1.000 MHz
Capacitance
0.001 nF…6.6 mF
Duty cycle function
5.0 %…95.0 %
Pollution degree
2
Measurement
categories
CAT IV 600 V, CAT III 1000 V
Safety cert.:
EN 61010/IEC 61010
Jaw opening
approx. 51 mm
Power supply
1 x battery 9 V, IEC 6F22
Dimensions
281 x 105 x 53 mm
Weight
approx. 560 g
Ordering Information:
Description
Safety set
Model 370003
Model
Model
Article no.
ACDC-3400 IND
ACDC-3400 IND3434889
TL36A
TL36A
Safety set
370003
3034444
2146666
45
Clamp meters | Leakage current clamp meters (AC)
AC50A
Digital leakage current clamp
(AC)
Functions
• Leakage current measurement
• Voltage and resistance measurement
• Continuity test with beeper
Product information
• Manual range selection
• Integrated measurement memory (data hold)
• MIN/MAX and relative value measurement
• Additional bar graph display
• Jaw opening 30 mm
• Auto Power Off
Product highlights
CAT II
600 V
400 V
AC
60 A
AC
• Minimum resolution: 0.01 mA
• Range of applications: Measurement of leakage
currents, e.g. stray or residual currents, current
consumption of units in service or customer service sector without interruption to circuit
Data
Hold
Technical specifications
Display
Ranges
Current AC
Tolerance
Voltage AC
Tolerance
Frequency range for
AC current/
voltage
Input resistance
Tolerance
Resistance
Tolerance
Continuity
Pollution degree
Measurement category
Safety cert.:
Jaw opening
Power supply
Dimensions
Weight
LCD, 3¾ digit, 3999 digits
0.01 mA...60 A
±(1.5 % rdg. + 5 digits)
0.1...400 V
±(2 % rdg. + 4 digits)
40 Hz...1 kHz
10 MΩ
0.1...400 Ω
±(1 % rdg. + 2 digits)
R<40 Ω
2
CAT II/600 V
DIN VDE 0411/EN 61010/
IEC 61010
approx. 30 mm
2 x battery 1.5 V, IEC LR6
210 x 62 x 36 mm
approx. 230 g
400Ω
Included:
Accessories:
1 x AC50A
2 x test leads
2 x battery 1.5 V, IEC LR6
1 x carrying case
1 x user manual
Adapters for stray current measurements:
Schuko/Schuko*
Model 1233
CEE 5-pole 16 A
Model 1235
CEE 5-pole 32 A
Model 1236
CHB5
Functions
• Leakage test
• Stray current measurement (leakage current
measurement) TRMS
• Voltage measurement (TRMS)
• Frequency verification
• Harmonics measurement for current and
voltage values (up to 99th harmonic)
Product information
• Integrated measurement memory (data hold)
• MIN/MAX value measurement
• Jaw opening 30 mm
• Auto Power Off
Product highlights
CAT II
600 V
CAT III
300 V
Hz
Included:
1 x CHB5
2 x test leads
2 x battery 1.5 V, IEC LR6
1 x carrying case
1 x user manual
600 V
AC
Data
Hold
• Minimum resolution: 0.01 mA
• Harmonics measurement
• Range of applications: Measurement of leakage
currents, e.g. stray or residual currents, current
consumption of units in service or customer
service sector without interruption to circuit
Accessories:
Adapters for stray current measurements:
Schuko/Schuko*
Model 1233
CEE 5-pole 16 A
Model 1235
CEE 5-pole 32 A
Model 1236
46
Description
Model
AC50A
AC50A
D* is German version
AC50A
AC50A-D*
Article no.
3033017
3454543
Test adapter:
Schuko/Schuko*
1233
2145900
CEE 5-pin 16 A
1235
2145921
CEE 5-pin 32 A
1236
2145939
* only for countries with Schuko plug
Technical specifications
Digital leakage current clamp
with harmonics measurement
TRMS (AC)
50 A
AC
Ordering Information:
* only for countries with Schuko plug
Display
LCD, 4 digit, 9999 digits
Ranges
Current AC
0.5 mA...50 A
Basic accuracy
±(1.5 % rdg. + 5 digits)
Voltage AC
0.1...600 V
Basic accuracy
±(0.5 % rdg. + 5 digits)
Frequency range for
AC current/
voltage
45 Hz...1 kHz
Input resistance
10 MΩ
Frequency measurement 45…65 Hz
Basic accuracy
±(0.2 Hz)
Harmonics
display up to 99th
Crest factor measurement
1.00…99.99
Basic accuracy
±(5 % rdg. + 30 digits)
Pollution degree
2
Measurement category CAT II/600 V, CAT III/300 V
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Jaw opening
approx. 30 mm
Power supply
2 x battery 1.5 V, IEC L 6
Dimensions
210 x 62 x 36 mm
Weight
approx. 200 g
Ordering Information:
Description
Model
Article no.
CHB5
93570
3313218
Measurement adapter:
Schuko/Schuko*
1233
CEE 5-pole 16 A
1235
CEE 5-pole 32 A
1236
2145900
2145921
2145939
Clamp meters (AC/DC) and current clamp adapters
LH41A
Digital current
clamp (AC/DC)
Functions
• Current measurement from 1 mA AC and DC
Product information
• Manual range selection
• Jaw opening 19 mm
• Automatic zero-point (DC measurement range)
• Integrated 5 s measurement memory (data hold)
• Auto Power Off
Product highlights
Technical specifications
Display
Ranges
Current AC/DC
Basic accuracy
Frequency range
Pollution degree
Measurement category
Safety cert.:
Jaw opening
Power supply
Dimensions
Weight
LCD, 4 digit, 4000 digits
0.001…40 A
±(1.3 % rdg. + 5 digits)
40...400 Hz
2
CAT lll / 300 V
DIN VDE 0411/EN 61010/
IEC 61010
approx. 19 mm
1 x battery 9 V, IEC 6LR61
184 x 71 x 31 mm
approx. 235 g
• Minimum resolution: 1 mA
• Shielded against external interference
CAT III
300 V
Data
Hold
Included:
1 x LH41A
1 x battery 9 V, IEC 6LR61
1 x user manual
CT235A
Current clamp adapter (AC/DC)
Functions
• Clamp adapter for extending the AC and DC
ranges of multimeters up to 1000 A AC/DC
Product information
• Can be used with all common multimeters; also
compatible with TRUE RMS multimeters and
analogue recorders
• Output Signal: 1 mV corresponds to 1 A test
current
• Jaw opening 32 mm
• Fixed test leads
• Zero adjustment
CAT III
300 V
1000 A
AC/DC
Included:
1 x CT235A
1 x battery 9 V, IEC 6F22
1 x user manual
Ordering Information:
Description
Model
Article no.
LH41A
LH41A
3030898
Technical specifications
Ranges
Current AC/DC
Basic accuracy
Output voltage
AC frequency
range: 50 Hz ... 10 kHz
Pollution degree
Measurement category
Safety cert.:
Jaw opening
Length of connection
cable
Power supply
Dimensions
Weight
approx. 1.5 m
1 x battery 9 V, IEC 6F22
approx. 195 x 70 x 30 mm
approx. 300 g
Ordering Information:
Description
Model
CT235A
CT235A
Technical specifications
Functions
Ranges
Current AC/DC
Basic accuracy
Output voltage
• Clamp adapter for extending the AC and DC
ranges of multimeters up to 200 A AC/DC
Product information
• Can be used with all common multimeters;
also compatible with TRUE RMS multimeters
and analogue recorders
• Output Signal: 10 mV corresponds to 1 A
test current
• Jaw opening 20 mm
• Fixed test leads
• Zero adjustment
200 A
AC/DC
2
CAT III/300 V
DIN VDE 0411/EN 61010/
IEC 61010
approx. 32 mm
CT237B
Current clamp adapter (AC/DC)
CAT III
300 V
200 A, 1000 A
± (1 % + 0.5 A)
1mV/A
Included:
1 x CT237B
1 x battery 9 V, IEC 6F22
1 x user manual
AC frequency
range
Pollution degree
Measurement category
Safety cert.:
Jaw opening
Power supply
Length of connection
cable
Dimensions
Weight
Article no.
3026809
20 A, 200 A
± (1.2 % + 0.03 A)
10 mV/A
(20 A measurement range)
1 mV/A
(200 A measurement range)
50 Hz ... 1 kHz
2
CAT III/300 V
DIN VDE 0411/EN 61010/
IEC 61010
approx. 20 mm
1 x battery 9 V, IEC 6F22
approx. 1.5 m
approx. 185 x 70 x 30 mm
approx. 280 g
Ordering Information:
Description
Model
CT237B
CT237B
Article no.
3511514
47
Measurement and test equipment
in accordance with (inter)national
standards
Measurement and test equipment in accordance with
DIN/VDE and EN 61557 are used to check electrical
safety in order to establish safety for people and
objects. Our measurement and test equipment is
divided into three groups in accordance with the
tests that are to be performed:
KMP series for UK only
Earth measurement
Socket tester
Installation testers
Portable Appliance Testers
Accessories
50
53
54
52
56
59
•
Testing electric machines (stationary) in
accordance with DIN VDE 0100/0105 and
EN 61557
•
Testing electric equipment (portable) in
accordance with DIN VDE 0701-0702 and
EN 61557
•
Testing electric machines in accordance with DIN
VDE 0113 and EN 61557
This equipment was developed in accordance with
the user's requirements and standards in order to
carry out tests in a fast, simple, and safe manner.
Most of our measurement and test equipment also
provide an integrated measurement memory for
creating a measurement report to make logging
along with our software packages much more
effective.
See our full line of UK specific single and
multifunction testers at beha-amprobe.com
Symbols used in this chapter
Low
Low ohm measurement
I∆
Leakage test
Rs
Measurement of loop resistance
IB
Measurement of touch current
Ri
Measurement of internal resistance
Optional
Software
Software optionally available
1
0
Trip test for residual current circuit breakers (RCD/FI)
RCD / FI
Earth Ground Testing
RCD-Test
Measurement
Memory
HS-
high-voltage
testing
RCD-FI test with increasing test current
No battery needed
LCD
Adjustable test time
TYP B
RCD-Test
ON
T
TES
PRCD
48
Display with LCD
Integrated socket test with contact electrode
socket test
Timer
SD
High-voltage testing
no battery
Adjustable curve form of test current (RCD/FI)
PC
Internal measurement memory
PC interface
Uses SD card memory storage
Touch screen
AUTO
TEST
Testing of AC/DC-sensitive RCD/FI
Automatic test sequence
Connection for barcode scanner
BARCODE
Testing of portable residual current
circuit breakers (PRCD)
Connection of an external current clamp
EXTERNAL
current clamp
49
Ground Resistance Tester
KMP7010
Ground Resistance Tester
according to BS7671 IEE
17th Edition regulations
Functions
• Measures Earth ground resistance
• Measure resistance of the grounding
systems to verify that the system has
low enough resistance to provide
protection for people, equipment
and structures
Technical specifications
(At 23°C ± 5°C. 45% to 75% RH)
Earth Resistance
Measurement
0.00Ω ~ 40.00Ω
0.0Ω ~ 40.00Ω
0Ω ~ 40.00Ω
± (2% rdg + 20 LSD)
± (2% rdg + 3 LSD)
± (2% rdg + 3 LSD)
Voltage Measurement
0Vac ~ 400Vac
± (1% rdg + 6 LSD)
@ 50/ 60 Hz
Operating Temperature
Storage Temperature
+5°C to +40°C. ≤80% RH, no condensation
-20°C to +60°C. ≤90% RH, no condensation
(without batteries)
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
1.5V Alkaline Battery (AA Battery) x 6 pcs
160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)
Approx. 500g (1.1 lb) with batteries installed
Designed to allow testing to BS7671
IEE 17th Edition regulations
BS EN 61010-1 CAT III 400V
BS EN 61557-1. BS EN 61557-5
BS EN 61326-1 (EMC)
Product information
• Measures Earth ground resistance
- 3 point (fall of potential) or 2 point
tests
• Voltage measurement prevents false
measurements
• Built-in memory to store 20
measurements
• Safety CAT III 600V
Product highlights
• Designed to allow testing to BS7671
IEE 17th Edition regulations, BS EN
61010-1 BS EN 61557-1, BS EN 615575, BS EN 61326-1 (EMC)
• Test leads, auxiliary electrodes are
included for a complete instrument
KMP7021
Included:
1 Pc. Test lead set for 3 point test
1 Pc. Auxiliary ground rods
1 Pc. Test lead set for 2 point test
1 Pc. Batteries (6 x AA)
1 Pc. User’s manual
1 Pc. Strap and carrying case
Accessories:
Description
Model
Single function
tester kit carry bag
KP1700
Specifications (At 23°C ± 5°C. 45% to 75% RH)
Functions
Operating Voltage
230Vac, 50 Hz
+10% to -15%
Trip current @ X½
10/20/30/100/300/500mA
(trip time 0 to 2000ms)
Trip current tolerance:
-10% to +10%
Trip time: ± (2% rdg + 2 LSD)
Trip current @ X1
10/20/30/100/300mA
Trip current tolerance:
(trip time 0 to 10000ms) 500mA 0% to +10%
(trip time 0 to 300ms)
Trip time: ± (2% rdg + 2 LSD)
Trip current @ X5
10/20/30mA
(trip time 0 to 40ms)
Trip current tolerance:
0% to +10%
Trip time: ± (2% rdg + 2 LSD)
Fast Trip Current
(KMP7021)
250mA (trip time 0 to 40ms)
Trip current tolerance:
0% to +10%
Trip time: ± (2% rdg + 2 LSD)
Ramp Test (KMP7021)
10/20/30/100/300/500mA -10% to +10%
Ramp increase by 10%
Default nominal residual currents from 20% to 110%
Maximum measuring time 300ms x 10 times
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
+0°C to +40°C. ≤80% RH, no condensation
-20°C to +60°C. ≤90% RH, no condensation
AC mains 230V + 10% - 15%, 50 Hz
160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)
Approx. 450g (0.99 lb)
Designed to allow testing to BS7671
IEE 17th Edition regulations
BS EN 61010-1 CAT III 300V
BS EN 61557-1. BS EN 61557-6
BS EN 61326-1 (EMC)
• Designed to check for correct
operation of RCD devices
• Three levels of trip currents (x1/2,
x1, x5) for complete range of testing
applications: Fast Trip Function and
Ramp Test
• Phase switch selection 0° and 180°
for positive and negative semi-cycle
testing
• Large display
• Safety CAT III 300 V
Product highlights
• 3-LED proper connection indicator
Displays mains voltage before test
• Designed to allow testing to BS7671
IEE 17th Edition regulations, BS EN
61010-1 CAT III 300V, BS EN 61557-1,
BS EN 61557-3, BS EN 61326-1 (EMC)
4160759
Technical specifications
Digital RCD Tester
according to BS7671 IEE
17th Edition regulations
Product information
Article no
Included:
1 Pc. 3-Wires mains test cord
1 Pc. Test lead set with leads/probes/alligator clips
1 Pc. User manual
1 Pc. Strap and carrying case
Accessories:
Description
Model
Article no
Standard test lead set
for KMP7030
SL7030
4160744
Single function
tester kit carry bag
KP1700
* Products are only available in UK
50
4160759
Ground Resistance Tester
Earth ground testing
KMP7030
Loop Impedance Tester
according to BS7671 IEE
17th Edition regulations
Functions
• Non Trip Loop test
• Loop testing is a quick, convenient,
and highly specific method of
evaluating an electrical circuit for its
ability to engage protective devices
(circuit breakers, fuses, RCDs)
• A ground loop determines the
effectiveness of protective devices,
therefore it is crucial to be able to
measure it, in order to detect and
correct problems
Product information
• Fast testing
• Instant reading
• Loop measurement ranges: 20, 200
& 2000Ω
• PSC measurement up to 20kA
• Backlight display
• Low Battery Indication
• CAT III 300V
Product highlights
• Displays mains voltage before test
• Instant correct wiring status check
• Designed to allow testing to BS7671
IEE 17th Edition regulations, BS EN
61010-1 CAT III 300V, BS EN 61557-1,
BS EN 61557-3, BS EN 61326-1 (EMC)
KMP7036
Insulation-Continuity
Tester according
BS7671 IEE 17th Edition
regulations
Functions
• Tests insulation of wires, cables,
transformers and electrical motors
Product information
• Selectable test voltages 250V, 500V
and 1000V
• Test button hold to perform the
Dielectric Absorption Ratio Test
• Continuity test at 200mA short-circuit
• Built in voltmeter and red light
warning for live circuit indication
• Automatic discharge of test object
after completion of measurement
• Test lead resistance zero facility
• Safety CAT III 600V
Product highlights
• Designed to diagnose the breakdown
of the insulation in various parts of
the electrical system such as wires,
transformers and motors
• Three testing voltages covering wide
range of commercial and residential
applications
• The quality of insulation is critical to
assure proper, uninterrupted and safe
functioning of electrical circuits
• Designed to allow testing to BS7671
IEE 17th Edition regulations BS EN
61010-1 CAT III 600V,
BS EN 615571 / -2 / -4 / -10, BS EN 61326-1 (EMC)
Technical specifications
Specifications (At 23°C ± 5°C. 45% to 75% RH)
Operating Voltage
230Vac, 45Hz ~ 65 Hz
+10% to – 15%
Loop Impedance
20/200/2000Ω
0 ~ 19.99 / 199.9 / 1999 Ω
±(3% rdg + 4 LSD)
AC Test Current
25A Nominal at 20Ω
AC Test Period
10ms at 20Ω
No Trip Loop Impedance 0 ~ 19.99 / 199.9 Ω
20 / 200Ω
(L – N im-pedance > 20 Ω)
PSC Measurement
0.0 ~ 1999.9 / 1999 / 19.9kA
200A / 2000A / 20kA
± (3% rdg + 6 LSD)
PSC accuracy derived from
measured loop impedance
spec-ification and measured
voltage specification
Voltage Measurement
100Vac ~ 300Vac
± (2% rdg + 4 LSD)
@ 50/60Hz
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
0°C to +40°C. ≤85% RH, no condensation
-20°C to +60°C. ≤90% RH, no condensation (without batteries)
1.5V Alkaline Battery (AA Battery) x 8 pcs
189 x 168 x 85 mm (7.43 x 6.65 x 3.35 in)
Approx. 450g (0.99 lb)
Designed to allow testing to BS7671
IEE 17th Edition regulations
BS EN 61010-1 CAT III 300V
BS EN 61557-1. BS EN 61557-3
BS EN 61326-1 (EMC)
Included:
1 Pc. Alligator clip set
1 Pc. batteries (8 x AA)
1 Pc. user manual
1 Pc. strap and carrying case
1 Pc. Mains test cord
1 Pc. Test lead set with
IEC connector
1 Pc. Test probe set,
Accessories:
Description
Model
Article no
Standard test lead set
for KMP7030
SL7030
4160744
Single function
tester kit carry bag
KP1700
4160759
Technical specifications
Specifications (At 23°C ± 5°C. 45% to 75% RH)
Insulation Resistance
@ 250V/500/1000V
(Test Current ≥1mA)
0.00MΩ ~ 4.99MΩ
5.0MΩ ~ 49.9MΩ
50MΩ ~ 999Ω
1.00GΩ ~ 1.99GΩ
(Buzzer threshold: 4MΩ)
Continuity
0.00MΩ ~ 9.99MΩ
@ IN ≥200mA,Uo=5Vdc 10.0MΩ ~ 99.9MΩ
(Nominal)
Operating Temperature
Storage Temperature
Power Supply
Dimensions (L x W x H)
Product Weight
Regulation Compliance
± (3% rdg + 5 LSD) for
0.00MΩ ~ 99.9MΩ
± (5% rdg + 5 LSD) for
100MΩ ~ 1.99GΩ
± (2% rdg + 3 LSD)
@ 50/ 60 Hz
0°C to +35°C. ≤75% RH, no condensation
-20°C to +60°C. ≤80% RH, no condensation (without batteries)
1.5V Alkaline Battery (AA Battery) x 6 pcs
160 x 101 x 71 mm (6.3 x 3.98 x 2.79 in)
Approx. 450g (0.99 lb) with batteries installed
Designed to allow testing to BS7671
IEE 17th Edition regulations
BS EN 61010-1 CAT III 600V
BS EN 61557-1 / -2 / -4 / -10
BS EN 61326-1 (EMC)
Included:
1 Pc. batteries (6 x AA)
1 Pc. user’s manual
1 Pc. carrying case and strap
2 Pc. Test leads
2 Pc. Test probes
2 Pc. alligator clips
Accessories:
Description
Model
Single function
tester kit carry bag
KP1700
Article no
4160759
Ordering Information:
Description
KPM7010
Model
KPM7010*
Article no.
3730256
KPM7021
KPM7021*
KPM7030
KPM7030*
KPM7036
KPM7036*
3730301
3842833
3730274
* Products are only available in UK
51
Measurement and test equipment in accordance with EN 61557 |
100 /200
TELARIS
ProInstall-100
®
Technical specifications
Combined installation
measurement equipment
Functions
• Measurement of loop resistance
• Measurement of internal network resistance
• Measurement of short circuit current
• Low resistance and continuity measurement
• Insulation test
• RCD/FI measurement (contact voltage, trip time,
trip current - increasing current)
• Voltage and frequency measurement
Product information
Low
test
voltage
test
voltage
test
voltage
100 V
250 V
500 V
1
Ri
Measurement
Memory
L3
L1
PC
0
RCD / FI
Rs
Optional
Software
L2
• Memory for approx. 400 readings with 3 levels
for assignment of distribution list numbers and
circuit numbers
• IR/USB interface for transferring the
stored measurement values to a PC
• Software for logging is optionally available for
printing out a test report
• Integrated socket test with contact electrode for
identification of incorrectly connected sockets
or missing protective earth
• Easy-to-read, large LC display with back lighting
and an especially large viewing angle
• Auto Power Off
Product highlights
socket test
• Compact, robust construction enables work to
take place even in harsh environments (weighs
only 1500g)
• A simple to use and intuitive user interface
enables you to work immediately and efficiently
• Probe with test button
Included
• Measurement of loop resistance and short circuit current without tripping RCD/FI
TELARIS
ProInstall-200
®
Combined installation
measurement equipment
as the ProInstall-100, also with:
• Testing of AC/DC-sensitive RCD/FI (type B)
• Memory for approx. 1000 readings
• Earth measurement (optionally with probes)
• RCD/FI analysis for testing all RCD/FI parameters
Display
LCD, 4 digit, 9999 digits
Measurement range/resolution
Voltage
50...500 V/1V AC
Frequency
45.0...65.0 Hz/0.1 Hz
Loop resistance
0.15…20/200/200 Ω
0.01/0.1/1 Ω
Short circuit current
0...10 kA
Input voltage
range
100...500 V 50/60 Hz
Test current
approx. 7 A (at 230 V)
Internal network
resistance
0.15…20/200/200 Ω
0.01/0.1/1 Ω
Short circuit current
0...10 kA
Input voltage
range
100...500 V 50/60 Hz
Test current
approx. 7 A (at 230 V)
approx. 5 mA (at 230 V)
Insulation resistance
0...1000 MΩ
0.01/ 0.1/1 MΩ
Test voltage
100, 250, 500, 1000 V DC
Low ohm measurement 0.05...20/200/2000 Ω
0.01/0.1/1 Ω
Test current
> 200 mA DC
RCD/FI rated residual
currents10, 30, 100, 300, 500, 1000 mA
Factors:
x1/2, x1, x5 and AUTO
RCD/FI types:
Standard AC, selective, pulsating,
B-type (only ProInstall-200)
Measurement functions contact voltage, trip time, trip
current test with rising test current
Contact voltage
0...50 V
Trip time
1...510 ms/1 ms
Trip current
30...110% of IDN
(in 10% increments)
Phase rotation test
Input voltage
range
100...500 V 50/60 Hz
Earth resistance
0.05...200 Ω / 2000 Ω
Probe resistance
0.1...52 kΩ
Max. measurement current
approx. 3.5 mA
Measurement voltage
approx. 25 V
Frequency
128 Hz/140 Hz
Overall
Measurement memory
approx. 400 to 1000 measurement
values
Interface
IR/USB
Safety cert.:
DIN VDE 0411/EN61010/
IEC61010 DIN VDE 0413/
EN61557/IEC61557
Measurement category CAT III/500 V, CAT IV/300 V
Pollution degree
2
Protection category
IP 40
Power supply
6 x battery 1.5 V, IEC LR6
Dimensions
110 × 260 × 130 mm
Weight
approx. 1500g (incl. batteries
Ordering Information:
Description
Included:
Low
test
voltage
test
voltage
test
voltage
100 V
250 V
500 V
1
Ri
L3
L1
0
RCD / FI
L2
Rs
PC
Optional
Software
TYP B
Measurement
Memory
socket test
RCD-Test
1 x ProInstall-100 or 200
3 x test leads
3 x crocodile clips
3 x probes
1 x probe with test button
1 x protective holster (integrated)
1 x hanging strap
1 x carrying case
6 x battery 1.5 V, IEC LR6
1 x quick start guide
1 x user manual on CD-ROM
1 x Schuko input line cord
Recommended Accessories
Software
Earth testing set
TL-EARTH
52
Article no.
ProInstall-100-D
ProInstall-100-D 4373971
ProInstall-100-DK ProInstall-100-DK 4399247
ProInstall-200-D
ProInstall-200-D 4373980
ProInstall-100-CH ProInstall-100-CH 4374484
ProInstall-200-CH ProInstall-200-CH 4374491
ProInstall-100-EUR ProInstall-100-EUR 4374504
ProInstall-200-EUR ProInstall-200-EUR 4374519
ProInstall-75-UK* ProInstall-75-UK 4826466
Please check which model is relevant for your
country:
D version for Germany, Austria only
DK version for Denmark only
CH version for Switzerland only
UK version for UK/Ireland only
EUR version for other EU countries except for
UK, Germany, Austria, Switzerland and Denmark.
4388671
USB download cable TL-USB
4372676
es control 0100
1312
2390062
Beha-Amprobe
DL-SW-KIT
4597359
downloader software with cable
Model
Additional accessories can be found at the end of
the chapter
* ProInstall-75-UK is not shown in this catalog,
for information please visit our website
beha-amprobe.com. Check for availability
for your country with your local distributor.
Measurement and test equipment in accordance with EN 61557 |
Earth ground testing
DGC-1000 A
Clamp meter for earth loop
measurement
Functions
• Earth loop measurement range: 0.025–1500 Ω
• Stray current measurement range
0.2...1000 mA
• Current measurement range: 0.2–30 A
Product information
• Measurement memory for 116 readings
• Recording interval 1...255 s
• Limit adjustment with alarm function
• Data hold function
• Jaw opening 23 mm
• Calibration loop included
Product highlights
• Earth measurement in closed earthing systems
without setting of earth stakes
• TRMS current measurement
Included:
1 x DGC-1000A
1 x battery 9 V, IEC LR6
1 x user manual
1 x calibration loop
1 x case
Technical specifications
Display
Display ranges/
Resolution
Earth resistance
Stray current
LCD, 4 digit, 9999 digits
0.025 ...1500 Ω
0.2…1.000/10.00/100.0/1000mA
0.001/0.01/0.1/1 mA
Current
0.2 A...4.000 A/30 A
0.001/0.01 A
Measurement memory for 116 readings
Recording interval
1 ... 255 s
Overall
Crest factor
<3
Pollution degree
2
Measurement category CAT III/300 V, CAT II/600 V
Safety cert.:
DIN VDE 0411/IEC 61010
Jaw opening
approx. 23 mm
Power supply
1 x battery 9 V, IEC 6LR61
Dimensions
257 x 100 x 47 mm
Weight
approx. 640 g
Ordering Information:
Description
Model
DGC-1000 A
DGC-1000 A
Article no.
2731217
Earth loop measurement with a clamp meter
In the case of earthing systems with
earths connected to each other that
create a closed loop (e.g. the lightning
protection system on a house), the
earth resistance of every earth loop can
be quickly and safely determined by
means of a clamp meter for earth loop
measurement (DGC-1000A).
A measurement current is induced in the
earth loop with a current clamp, whilst
the current running through the earth is
measured with a second clamp in order
to derive the resistance of the earth loop
for the relevant earth.
The DGC-1000A clamp meter is a clamp
with two current clamps in practical
terms, which are installed within a
housing. This clamp combines the two
current clamps needed to perform
the stakeless ground loop test in one
compact and easy to use instrument.
53
Socket Tester
Schuko-Test FI/RCD
Socket tester with RCD/FI tripping
Functions
• Fast and effective testing of 30 mA RCD/FI
• Testing for correct/incorrect wiring
• Connection test for individual conductors (L-NPE)
• PE fault detection
Product information
• True PE fault detection via LCD and contact
electrode
• Detection of wiring faults with classic protective
earthing
Product highlights
• Clear and reliable indication of PE faults via LCD
screen
Technical specifications
Nominal voltage
Frequency range
RCD/FI test current
RCD/FI test time
Contact voltage
with break-off at
monitoring
PE fault detection
Response threshold
Safety cert.:
230 V AC ±10%
50...60 Hz
30 mA
< 300 ms
20...25 V AC/DC
25 V AC
DIN VDE 0411/EN 61010/
IEC 61010
Measurement category CAT II/300 V
Pollution degree
2
Power supply
from mains voltage
Dimensions
70 x 55 x 86 mm
Weight
approx. 75 g
1
0
RCD / FI
no battery
LCD
socket test
D Utility model
29822508.5
Included:
1 x Schuko test FI/RCD
1 x user manual
Ordering Information:
Description
Model
Article no.
Schuko test FI/RCD
9080*
3530534
* Packing unit of 10 items (also available individually)
* Tester is available for countries with a Schuko plug
only
Socket test
FI/RCD testers contain a display for
testing the pin assignment specifically
intended for testing an earthed socket.
With all RCD/FI testers, the contact voltage is monitored and any PE faults are
clearly displayed.
54
Measurement and test equipment in accordance with EN 61557 |
Megohmmeters
93530
Technical specifications
Functions
Display
Display range/resolution
Insulation resistance
Megohmmeter
• Insulation test
• Voltage measurement
• Resistance and continuity measurements
with beeper
Product information
• Built-in measurement memory for 9 readings
• Lock function enables continuous operation
• Zero adjustment with resistance measurement
• Backlit display
• Additional bar graph display
test
voltage
test
voltage
test
voltage
Prüfspannung
100 V
250 V
500 V
1000 V
Measurement
Memory
Test voltage
Test current
Voltage AC/DC
Continuity measurement
Resistance measurement
Safety cert.:
Measurement category
Pollution degree
Power supply
Dimensions
Weight
9999 Ω
LCD, 4 digit; 9999 digits
0...999.9 kΩ/0.1kΩ,
9.999 MΩ/0.001 MΩ,
99.99 MΩ/0.01 MΩ,
999.9 MΩ/0.1 MΩ,
9.999 GΩ/0.001 GΩ (at
>250V)
100, 250, 500, 1000 V
>1 mA
0...600 V / 1 V
0...999.9 Ω/0.1 Ω
(sound at <40 Ω)
0...9999 Ω/1 Ω
DIN VDE 0411/EN 61010/
IEC 61010,
DIN VDE 0413, T. 2/
EN 61557-2/IEC 61557-2
CAT III/600 V
2
6 x battery 1.5 V, IEC LR6
200 x 95 x 48 mm
approx. 500 g
Bargraph
Included:
1 x insulation tester 93530
2 x test leads
1 x crocodile clip
1 x probe
1 x carrying case
6 x battery 1.5 V, IEC LR6
1 x user manual
Ordering Information:
Description
Model
93530
93530-D
Article no.
3454416
Things to know about insulation measurement:
One of the most important measurements
of an electrical system is insulation
measurement. It is the only measurement
for fire and touch protection, amongst
others. If electrical cables are energised
then residual currents flow, which
generate heat or electrolytic material
migrations. If a limited residual current
flows between two cables due to an
insulation fault, then the current can
lead to warming and in extreme cases to
fire.
These residual currents are generally so
small that preset protection systems such
as RCD/FI protection systems or fuses do
not detect them. The DIN VDE allows for
a residual current with a heat output of
1mA/kW. The values that are measured
in practice on a new unit are, however,
considerably lower.
Insulation
measurement
is
a
measurement that does not require a
mains connection and can therefore take
place early, before, for example, a faulty
wire is plastered in and where fault
detection or elimination can be very
demanding. If the readings are logged,
then if a fault appears later on, it can be
shown whether it was caused by other
tradespeople involved with construction.
Insulation resistance is a complex form of
resistance, comprising several different
individual resistances and capacitances.
The inflow from capacitor C is switched
off when the measurement is carried
out with direct current or direct voltage.
In order to obtain a meaningful,
comparable reading, the test voltages
and the test currents are established so
that the inflow of the current or voltagedependent resistances (Ru, Ri) remain
identical.
The resistance (RD) of the dielectric
is affected by moisture and the timedependent resistance (Rt) is affected
by the aging of the materials used
(Rw), which can lead to different
results for readings at different times.
Measurement of the insulation resistance
must be carried out between every active
conductor and earth upon initial testing.
Replacement circuit diagram of the insulation
resistor from L to N
55
Equipment tester in accordance with EN 61557
GT-400
Technical specifications
Portable equipment tester in
accordance with UK code of
practice & DIN VDE 0701-0702
Functions
• Measurement of protective earth resistance
• Insulation resistance measurement
• Measurement of protective earth and touch current (alternative stray current procedure)
Product information
• Automatic test sequence for equipment in protection class I, protection class II/III
• Automatic testing of extension cables, socket
strips, and IEC cables
• Clear display via symbols in case of non-adherence to threshold values
• Preset threshold values in accordance with UK
Code of Practice DIN VDE 0701-0702
AUTO
TEST
Product highlights
• Battery-operated - ideal for mobile use
• Suitable for trained people due to the Pass/Fail
descriptive function
• Simple to use due to a rotary switch and start
button
Included:
Accessories:
1 x equipment tester GT-400
1 x measurement accessories set with safety test
line, Safety crocodile clip and safety probe
6 x battery type AA
1 x IEC power cable 0.5m
1 x carry case
1 x user manual
Leakage current clamp
AC50A
Measurement adapter Schuko/
Schuko
1233*
Display
Measurement range
Resolution
Protective earth
resistance
Test current / voltage
Test current/voltage
Insulation resistance
Test current / voltage
Equivalent stray current
Test voltage
Overall
limit value display
Measurement category
Pollution degree
Protection class
Protection category
Power supply
Dimensions (W*H*D)
Weight
Graphic LCD
0.10…2.00 Ω
> ± 200 mA DC / > 4 V
> 5 A / approx. 6 V AC
0.1…20 MΩ
> 500 V DC / > 1 mA
0.1...20 mA
approx. 32 V AC
via symbols in LCD
Safety cert.: DIN VDE 0404
DIN VDE 0411/EN 61010/
IEC 61010
DIN VDE 0413/EN 61557/
IEC 61557
CAT II/300 V
2
II
IP 40
6 x 1.5 V battery, IEC LR6 (AA)
approx. 265 x 110 x 50 mm
approx. 700g
Ordering Information:
Description
Model
Article no.
GT-400-D
GT-400-D
4380998
GT-400-CH
GT-400-CH
4381001
GT-400-UK
GT-400-UK
4381012
D version for Germany, Austria and all other
countries using the Schuko plug
CH version for Switzerland only
UK version for UK only
Test report 0701-0702
1279
Check for availability for your country with your
local distributor.
Recommended accessories
AC50A AC50A-D 3454543
Schuko test adapter
1233
2145900
Test log 0701-0702
1279
3313435
Additional accessories can be found at the end
of the chapter
Application example for a leakage test under mains voltage:
Leakage current clamp
AC50A and measurement adapter
Schuko/Schuko 1233
56
L
N
PE
Measurement and test equipment in accordance with EN 61557 |
Equipment tester in accordance with EN 61557
GT-600
Equipment tester in accordance
with DIN VDE 0701-0702
Functions
• Measurement of protective earth resistance
• Insulation resistance measurement
• Measurement of equivalent stray current
• Measurement of protection earth current
• Measurement of touch current
• Performance measurement, load voltage, load
current, power factor
• Direct testing of IEC cables without adapter
device information
Product information
PC
Optional
Software
Measurement
Memory
AUTO
TEST
BARCODE
ON
T
TES
EXTERNAL
current clamp
PRCD
Included:
1 x GT-600 with accessory case (fixed to device lid,
removable)
1 x test lead
1 x probe
1 x crocodile clip
1 x interface cable (USB)
1 x user manual
• Memory for approx. 3800 readings, real-time
clock
• 3 memory levels (client, location, department)
• Integrated interface (USB 2.0)
for transferring measurements to PC
• Separate interface (USB 2.0) for connecting a
barcode scanner and keyboard
• Graphical LCD for measured values, limit values
and parameters
• Wiring diagrams and limit values on
device lid
• Simple operation with rotary switch
• Manual test sequence
• Clear display "Test OK/not OK"
• Test lead compensation
• Compact and robust carrying case
• Convenient software with
"es control professional“ database for logging
purposes available (optional)
Product highlights
• 5-A and 0.2-A test current for protective earth
resistance
• Differential current procedure for protective
earth current
• Direct measuring procedure for touch current
• Fast safety and function check of IEC cables
• Connection for barcode scanner for reading in
sample numbers and test sequences
• Suitable for trained people due to the good/bad
descriptive function
Technical specifications
Display
Display ranges
Protective earth
resistance
Test current/voltage
Test current/voltage
Insulation resistance
Test current / voltage
graphical LCD, 128 x 64 pixels
0.01...10.0 Ω
> 200 mA / approx. 6 V AC
> 5 A / approx. 6 V AC
0.01...50 MΩ
500 V DC / > 1 mA
(250/500 V only GT-800)
Equivalent stray current 0.25...20 mA
Test voltage / current
approx. 45 V AC / approx. 260 mA
Protective earth current 0.25...20 mA
(Differential current procedure)
Touch current
0.02...2 mA
(Direct measurement procedure)
Apparent power
30 W...4.04 kVA
Active power
30 W...4.04 kW
Load voltage
195...253 V
Load current
0...16 A
Power factor
0...1
Voltage measurement
SELV/PELV
10.0…150 V AC/DC
External
current clamp input
0.0 ... 20.0 mA
0.2 ... 60.0 A, for clamp adapter
1000:1 (only GT-800)
Test functions of PRCD (only GT-800)
Protective earth, insulation,
function, protective earth current,
RCD test:
½x IΔN, 1x IΔN, 5x IΔN, and
trip current (ramp)
PRCD types
2-pole, 3-pole, and S-type
Mains fuse
2 x T16 A
Overall
Measurement memory 3800 measurement values, corresponds to
approx. 260 meter measurements
Interface (USB 2.0)
for PC
Interface (USB 2.0)
for barcode scanner and keyboard
Limit value display
optical and acoustic
Safety cert.:
DIN VDE 0404 parts 1, 2,
DIN VDE 0411-1 / EN 61010-1
DIN VDE 0413/EN 61557 parts 2, 4
Measurement category CAT II/300 V
Protection category
IP 40
Power supply
230 V +10%/-15% 50/60 Hz
Power consumption
approx. 45 VA
Dimensions
300 x 250 x 130 mm
Weight
approx. 4.5 kg
Ordering Information:
Adapter cable ACF-6A
Description
Model
Article no.
GT-600*
GT-600
4151632
Recommended Accessories
Leakage current clamp
adapter CHB1
1311
2390055
Adapter cable
ACF-6A
2743889
Barcode scanner
BC-1250G
BC-1250G
4377939
Keyboard KBGEMT204S
KBGE-MT204S 3504388
Software es control
0701-0702/0113
1314
2390081
(without interface adapter)
Further accessories are at the end of the chapter
* only available for countries which use a
Schuko plug
57
Equipment tester in accordance with EN 61557
GT-800
Automatic equipment tester
in accordance with
DIN VDE 0701-0702
as the GT-600, also with:
• Automatic test sequence, with input from custom test sequences
• Connection for external current clamp adapter
for measurement of protective earth currents,
even on 3-phase samples
• Testing of portable residual current circuit
breakers (RCDs)
• Test voltage for insulation measurement, switchable 250 / 500 V
• Automatic polarity of mains socket
PC
Optional
Software
Measurement
Memory
AUTO
TEST
BARCODE
ON
T
TES
EXTERNAL
current clamp
PRCD
Included:
1 x GT-800 with accessory case (fixed to device lid,
removable)
1 x test lead
1 x probe
1 x crocodile clip
1 x interface cable (USB)
1 x user manual
Adapter cable ACF-6A
Technical specifications
Display
Display ranges
Protective earth
resistance
Test current/voltage
Test current/voltage
Insulation resistance
Test current / voltage
graphical LCD, 128 x 64 pixels
0.01...10.0 Ω
> 200 mA / approx. 6 V AC
> 5 A / approx. 6 V AC
0.01...50 MΩ
500 V DC / > 1 mA
(250/500 V only GT-800)
Equivalent stray current 0.25...20 mA
Test voltage / current
approx. 45 V AC / approx. 260 mA
Protective earth current 0.25...20 mA
(Differential current procedure)
Touch current
0.02...2 mA
(Direct measurement procedure)
Apparent power
30 W...4.04 kVA
Active power
30 W...4.04 kW
Load voltage
195...253 V
Load current
0...16 A
Power factor
0...1
Voltage measurement
SELV/PELV
10.0…150 V AC/DC
External
current clamp input
0.0 ... 20.0 mA
0.2 ... 60.0 A, for clamp adapter
1000:1 (only GT-800)
Test functions of PRCD (only GT-800)
Protective earth, insulation,
function, protective earth current,
RCD test:
½x IΔN, 1x IΔN, 5x IΔN, and
trip current (ramp)
PRCD types
2-pole, 3-pole, and S-type
Mains fuse
2 x T16 A
Overall
Measurement memory 3800 measurement values, corresponds to approx. 260 meter
measurements
Interface (USB 2.0)
for PC
Interface (USB 2.0)
for barcode scanner and keyboard
Limit value display
optical and acoustic
Safety cert.:
DIN VDE 0404 parts 1, 2,
DIN VDE 0411-1 / EN 61010-1
DIN VDE 0413/EN 61557 parts 2, 4
Measurement category CAT II/300 V
Protection category
IP 40
Power supply
230 V +10%/-15% 50/60 Hz
Power consumption
approx. 45 VA
Dimensions
300 x 250 x 130 mm
Weight
approx. 4.5 kg
Ordering Information:
Description
Model
Article no.
GT-800*
GT-800
4151644
GT-800-CH**
GT-800-CH
4460614
* only available for countries which use a Schuko
plug
** Only available for Switzerland
Recommended Accessories
Leakage current clamp
adapter CHB1
1311
2390055
Adapter cable
ACF-6A
2743889
Barcode scanner
BC-1250G
BC-1250G
4377939
Keyboard
KBGE-MT204S
KBGE-MT204S 3504388
Software es control
0701-0702/0113
1314
2390081
(without interface adapter)
Further accessories are at the end of the chapter
58
Accessories
Earth measurement set
perfect for:
• e.g. Telaris ProInstall-200
Included:
Ordering Information:
Description
Model
Earth measurement set TL-EARTH
Article no.
4388671
1 x carrying case
2 x ground spikes (235 x ’ 10 mm)
1 x test lead, red, 25 m
1 x test lead, blue, 25 m
1 x test lead, green, 5 m
3 x test lead winders
3 x crocodile clips
Barcode Scanner
• For reading in barcoded sample numbers*
Model 1325 for:
• For MACHINEmaster (Model 9050)
Model BC-GT07XX for:
• for equipment tester GT-0751
Model BC-1250G for:
• for machine tester MT 204-S (Model 9085)
• for equipment tester GT600 and GT800
Ordering Information:
Description
Model
Article no.
Barcode scanner
1325
3223132
Barcode scanner
BC-GT07XX
BC-GT07XX
3504434
Barcode scanner
BC-1250G
BC-1250G
4377939
Barcode sticker
(250 pcs. on roll)
1063
2389952
Barcode sticker
Barcode scanner
BC-1250G
1063
• Abrasion-resistant numbered barcodes for
identifying samples
• Consecutive numbering
• Barcoded (code 39) and clear text
• Size 54 x 15 mm
• For 0701/0702 test equipment
• For MACHINEmaster (Model 9050)
* for reading in code 39, code 128, code 2/5, EAN,
UPC barcodes
KBGE-MT204S
Description
Model
• For convenient entry of client/sample
information on site
• For equipment tester GT600 and GT800
Keyboard
KBGE-MT204S 3504388
AC current clamp adapter
Ordering Information:
• Current measurement from approx. 1 mA to
1000 A
• Jaw opening 48 mm
• Current output, output signal:
1 mA corresponds to 1 A test current
• Fixed test lead
• No batteries required
1000 A
AC
Ordering Information:
USB keyboard
Description
Model
AC current clamp adapter 1226
Article no.
Article no.
3313401
Output
Analog
59
Measurement and test equipment in accordance with EN 61557 | Accessories
Measurement adapter
Ordering Information:
Description
for stray current/
leakage current measurement
Measurement adapter:
Schuko/Schuko*
1233
CEE 5-pole 16 A
1235
CEE 5-pole 32 A
1236
1233
• Measurement adapter for measuring differential current, protective earth current, load current, and neutral conductor current in portable
consumers via a leakage current clamp
• All conductors are individually brought out
* only for countries with Schuko plug
L
N
PE
Wiring diagram 1233
1235
Application example for a leakage test
under mains voltage
(leakage current) e.g. with
AC50A, CHB5, or CHB1
L1
L2
L3
N
PE
Wiring diagram 1235/1236
1236
Application example for a
leakage test
under mains voltage
(leakage current) e.g. with
AC50A, CHB5, or CHB1
VLP 5
Three-phase current extension
test adapter
• For testing portable equipment and extension
cables with the plugs and couplings:
· 16 A CEE 3-pole
· 16 A CEE 5-pole
· 32 A CEE 5-pole
· IEC power cable and Schuko
• Measurement of protective earth resistance,
insulation resistance, function of active conductors (L-N), and rotary field
• Suitable for all test equipment with an earthed
socket and test probe
Ordering Information:
Description
Model
VLP5
1343
60
Article no.
3313514
Model
Article no.
2145900
2145921
2145939
Accessories
DAA-16, DAA-32
Three-phase adapter 16 A or 32 A
• Three-phase current plug CEE 16 A or CEE 32 A
• Connections via five separate 4 mm sockets
for L1, L2, L3, N and PE
• For quick connection of test devices to threephase sockets when testing according to DIN
VDE 0100
Ordering Information:
Description
Model
DAA-16*
DAA-16
DAA-32*
DAA-32
Article no.
2743806
2743850
* with Schuko plug
DAA-16, DAA-32
Three-phase adapter
1142
• For testing portable equipment with the plugs:
16 A CEE 3-pole, 16 A CEE 5-pole, and 32 A CEE
5-pole
• Measurement of protective earth resistance and
insulation resistance
• Suitable for all test equipment with an earthed
socket and test probe
Three-phase adapter
1240/1241
• For testing portal devices with three-phase
current plug 16 A CEE 5-pole (1240) or 32 A CEE
5-pole (1241)
• Measurement of protective earth resistance and
insulation resistance
• Suitable for all test equipment with an earthed
socket
Ordering Information:
Description
Model
Three-phase adapter*
1142
Article no.
3313394
* with Schuko plug
Ordering Information:
Description
Model
Article no.
Three-phase adapter
16A*
1240
3313412
Three-phase adapter
32A*
1241
3313420
* with Schuko plug
1240/1241
61
Measurement and test equipment in accordance with EN 61557 |
Accessories
CHB1
Leakage current clamp adapter
(AC)
Functions
• Clamp adapter for measuring leakage currents
in conjunction with a multimeter
• Stray current measurement in connection with
GT-800
Product information
50 A
AC
Output
• Current output, output signal:
1 mA corresponds to 1 A test current
• Jaw opening 30 mm
• Fixed test leads
• No batteries required
• Not suitable for earth measurements
Ranges
Current AC
Basic accuracy
Output current
Frequency range
Protection class
Pollution degree
Measurement category
Safety cert.:
1mA ...50 A
± (6 % + 0.5 mA)
1 mA/A
40 Hz…10 kHz
IP 30
2
CAT II/600 V
DIN VDE 0411/EN 61010/IEC
61010
Jaw opening
approx. 30 mm
Length of connection cable
approx. 1.5 m
Dimensions
approx. 140 x 45 x 20 mm
Weight
approx. 75 g
Ordering Information:
Analog
PAT-BRUSH
Description
Model
CHB1
1311
Description
Model
• Measurement of protective earth resistance and
touch current
• Enables stray current measurement on moving or
rotating parts
• Reduces transition resistance due to multiple
contacting
• Simplifies measurement on refined or oxidized
surfaces
• Max. test current 0.2 A
• 4 mm plug-in technology
• Total length 190 mm, brush dimensions 60 mm x
Æ20 mm
• With protective packaging for safe storage
• Can be used for all testing equipment
Brush probe
PAT-BRUSH
2390055
Article no.
4151667
Ordering Information:
Adapters for protective earth
Description
• Measurement of protective earth resistance
with securely attached equipment
• Secure contacting of the protective earth to a
Schuko socket
• 4 mm plug-in technology
Adapter for protective
earth
ADAPTER-PE
PA-1
Article no.
Ordering Information:
Brush probe
ADAPTER-PE
62
Technical specifications
Model
Article no.
4151659
Ordering Information:
Adapter for 3-pole plug
Description
Model
• Measurement of protective earth resistance and
insulation
• For C5 power cable types
(DIN VDE 0623, IEC/EN60320)
Adapter for
3-pole plug
PA-1
Article no.
4362289
Software packages for
logging purposes
Test reports act as evidence of proper
performance of the work carried out,
and provide the client and the company
that has been commissioned clear
documentation regarding safety.
Software packages from Beha-Amprobe
provide a convenient, practical
solution in order to transfer data from
measurement and testing equipment by
quickly and easily creating a test report
and archiving the measurement data.
Compared to manual creation this
results in time being saved, particularly
with repeat testing services and
verifications.
Products
es control professional
Downloader Software
64
63
Software | Which software for which device
Software
es control professional
0100
es control professional
0701-0702/0113
es control professional
Complete
Beha-Amprobe
Downloader Software
Test equipment:
Model 1312
Model 1314
Model 1316
Model DL-SW-KIT
PROINSTALL-100
•
•
•
PROINSTALL-200
•
•
•
GT-600
•
•
GT-800-CH
•
•
GT-0751
•
•
MACHINEmaster
•
•
MT 204-S
•
•
DL-SW-KIT
Downloader Software
Key Features
System requirements
• Software for logging measurement data in
accordance with DIN VDE 0100 and 0105. Downloads data from supported meters:
- ProInstall-100
- ProInstall-200
• Displays downloaded data using form and table
view for easy analysis
• Allows saving, retrieving and printing of the
downloaded data
• Provides standard form templates to quickly log
results with professional quality
• Exports data to other programs such as Microsoft Excel using the CVS format
• Provides utility to clear memory and to change
meter setup
• Opto-isolated USB interface for user and computer safety
• Preview of the stored measurement values on
the PC using Virtual Meter function
Operating System: Windows 7, 8 or 10.
Minimum recommended hardware: Pentium class
microprocessor, 32 MB RAM, and up to 70 MB
hard disk space (100 MB to install)
Supported instruments
• ProInstall-100
• ProInstall-200
Ordering Information:
Description
Model
Downloader Software
es control professional
Software packages
• Convenient, upgradeable software for logging
measurement data in accordance with DIN VDE
0100, 0701-0702, 0751, and 0113
• Access authorization/user administration for
four different user groups
• Comparison and update of different es control
databases (replication)
• Interface to external barcode printing programs
(Brother® P-Touch), allowing the sample number
and test code to be printed as a barcode
• Result evaluation for tests in accordance with
DIN VDE 0100 for quick evaluation of overall
test
• Ideal software for all providers of repeat testing
services according to BetrSichV (German Ordinance on Industrial Health and Safety) or in the
field of facility management
• Interface cable not included in delivery (optional)
Software in English/German language version
available.
64
DL-SW-KIT
Ordering Information:
Description
Model
Article no.
4597359
Article no.
es control
professional 0100
(without interface cable) 1312
2390062
es control
professional 0701-0702/0113
(without interface cable) 1314
2390081
es control professional
Complete
(without interface cable) 1316
2390735
USB download cable for
ProInstall series
TL-USB
4372676
RS-232 on USB adapter 1217
2389965
Downloader Software
DL-SW-Kit
4597359
DL-SW-KIT
Software
es control
professional
0100
Model
DIN VDE 0100, 0105
es control
professional
0701-0702/0113
•
•
DIN VDE 0701-0702, 0751-1/
EN 62353 and 0113
Clear and simple hierarchy
•
Data tree (client, unit, test, distributor, and circuit)
•
Operating system
Processor
RAM
Screen
Memory
Drive
Interface
Win XP, Win 7, Win 8/8.1,
Win 10
Pentium IV or similar processor*
256 MB or higher
VGA monitor or monitor
with higher resolution;
Super VGA recommended:
Resolution 800 x 600 or
greater available
400 MB
CD-ROM
RS232; 9-pole or USB
(dependent on tester)
* Windows 7, 8 and 10 are registered trademarks of
the Microsoft Corporation
Included:
1 x software on CD-ROM
(es control professional 0100,
es control professional 0701-0702/0113, or es
control professional Complete)
1 x user manual
Price
advantage!
0751
0701/
0702
0113
professional
0100
Save upon purchasing
a complete package
(all modules)
compared to
buying all individual
modules separately.
•
•
•
•
•
Data tree (customer, location, department, sample, and test)
Recommended configuration
for es control software
es control
professional
Complete
•
•
•
•
•
Automatic creation of new devices under test that are not yet
in the database. Tests can thus be
printed out quickly and easily.
•
•
•
Results of a standard test report
for electrical systems
•
Transfer of measured values from
tester to PC
•
Results of a test series can be
printed out in form of a list or
individual logs for each DUT
•
•
•
•
Lists can be exported in text
and Excel format
•
Assistant for reading in data
and printing out reports
•
Access authorization/user administration for four different user
groups
•
•
•
Comparison and update of
different es control databases
(replication)
•
•
•
Result evaluation for tests in
accordance with DIN VDE 0100
for quick evaluation of overall
test
•
•
•
Data export to external barcode
printing programs (Brother®
P-Touch), allowing the sample
number and test code to be
printed as a barcode
Accessories:
USB adapter including driver
Model 1217
•
•
Ordering Information:
Description
Model
Article no.
es control professional
0100
1312
2390062
es control professional
0701-0702 / 0113
1314
2390081
es control professional
Complete
(all modules)
1316
2390735
USB data cable for
ProInstall series
TL-USB
RS-232 on USB adapter 1217
4372676
2389965
Beha-Amprobe
Downloader Software
with interface cable
DL-SW-KIT
4597359
Environmental testing:
Temperature, light, sound,
humidity, rotational speed
Within the field of environmental testing,
we provide a wide range of thermometers
and appropriate thermal sensors for every
application.
In addition, our range of environmental
testing products also features a selection
of various meters such as moisture meters,
sound level meters, and light meters
for measuring illumination, e.g., in the
workplace.
Products
Temperature meters
Moisture meters
Temperature / RH data logger
Temperature sensors / accessories
Light meters
Sound level meters
Anemometers
Tachometers
Symbols used in this chapter
NTC
Typ
Typ
Data
Hold
NTC as thermal element
NiCr/Ni thermo-element (K-type)
Measurement memory
Min/max value memory
Back light
66
Infra-red measurement
data
logger
DATA HOLD
Data Logger
Alarm function
PC
PC interface
Dew point measurement
67
70
72
73
74
75
77
78
Temperature Meters
IR608A
Technical specifications
Infrared thermometer
Display
Measurement ranges
Functions
• Non-contact temperature measurement
Product information
• Switchable between °C and °F measurement
• Integrated measurement memory (data hold)
• Illuminated display
• Distance to spot size ratio: 8:1
• Auto Power Off
Resolution
Basic accuracy
Emissivity
Response time
Power supply
Dimensions
Weight
LCD, 4 digit
-18...+400°C
0 ... 750° F
0.2°C / 0.5°F
±2% or ±2°C (±3.5°F)
0.95 (preset)
500 ms
1 x battery 9 V, IEC 6LR61
152 x 101 x 38 mm
approx. 227 g
Product highlights
• Laser-based targeting
• Handy and compact design
in pistol format
Data
Hold
Included:
1 x IR608A
1 x battery 9 V, IEC 6LR61
1 x user manual
Ordering Information:
Description
Model
Article no.
IR608 A
IR608A
3015690
IR-450-EUR
Technical specifications
Mini infra-red thermometer
with flashlight
Display
Measurement ranges
Resolution
Basic accuracy
Emissivity
Response time
Power supply
Dimensions
Weight
Functions
• IR temperature measurement
• LED flashlight
Product information
• Ratio of spot size to distance 8:1
• °F / °C selectable
• Temperature is displayed for 10 seconds
• With pocket clip
LCD, 3 digit
-30...+500° C; 20 ... 932° F
0.2° C / 0.5° F
±1.5% or ±2° C (±3° F)
0.95 (preset)
500 ms
1 x battery 1.5 V, IEC LR03, AAA
100 x 20 x 29 mm
approx. 50 g
Product highlights
• With laser pointer
• Small and compact
Included:
1 x IR-450-EUR
1 x battery 1.5 V, IEC LR03, AAA
1 x user manual
Ordering Information:
Description
Model
IR-450-EUR
IR-450-EUR
Article no.
4308539
67
Environmental testing| Temperature meters
IR-710-EUR
Infrared Thermometer 10:1
Functions
• Non-contact temperature measurement
Product information
• Temperature measurement from -18° to 380°C
• Integrated measurement memory (data hold)
• MIN/MAX measurement memory
• Illuminated display
• Distance to spot size ratio: 10:1
• Very fast response time
• Auto Power Off
IR-710-EUR
Product highlights
• Laser-based targeting
• Handy and compact "pistol grip" design
Data
Hold
IR-712-EUR
Infrared Thermometer 12:1
Technical specifications
Display
Measurement ranges
Resolution
Basic accuracy
Emissivity
Response time
Ratio of
spot size to
distance
Laser
Power supply
Dimensions
Weight
LCD, 4 digit
-32...+1550°C
0.1°C < 999.9 °C / 1°C > 999.9 °C
±1.8% or ±1.8° C
Adjustable between 0.10…1.00
250 ms
50:1
1-point laser >1mW Class 2
1 x battery 9 V, IEC 6LR61
183 x 147 x 57 mm
approx. 345
Power supply
Dimensions
Weight
1 x battery 9 V, IEC 6LR61
183 x 147 x 57 mm
approx. 345
* Technical data relates to the highest model in
the series (IR-750-EUR). Data regarding individual models can be found on our website www.
beha-amprobe.com
as the IR-710-EUR, also with:
• Temperature measurement from -18° to 550°C
• Distance to spot size ratio: 12:1
• Continuously adjustable emissivity
• Integrated thread for tripod
• Measuring the average temperature
IR-712-EUR
IR-720-EUR
IR-730-EUR
IR-720-EUR
Infrared Thermometer 20:1
as the IR-712-EUR, also with:
• Temperature measurement from -32° to 1050°C
• Distance to spot size ratio: 20:1
Data
Hold
IR-730-EUR
Infrared Thermometer 30:1
as the IR-720-EUR, also with:
• Temperature measurement from -32° to 1250°C
• Distance to spot size ratio: 30:1
IR-750-EUR
Infrared Thermometer 50:1
as the IR-730-EUR, also with:
• Temperature measurement from -50° to 1550°C
• Distance to spot size ratio: 50:1
• Adjustable alarm function
• Data memory up to 99 readings
• USB interface for transferring
stored measurements to a PC
• Input for K-type test probe
IR-750-EUR
Included:
Data
Hold
PC
68
Typ
1 x IR-710-EUR, IR-712-EUR, IR-720-EUR,
IR-730-EUR, IR-750-EUR
1 x battery 9 V, IEC 6LR61
1 x carry case (only for IR-712-EUR, IR-720-EUR,
IR-730-EUR, IR-750-EUR)
1 x user manual
1 x USB cable (only IR-750-EUR)
1 x software on CD (only IR-750-EUR)
1 x hard carrying case (only IR-750-EUR)
1 x K-type wire probe (only IR-750-EUR)
Ordering Information:
Description
Model
Article no.
IR-710-EUR
IR-710-EUR
4308480
IR-712-EUR
IR-712-EUR
4308498
IR-720-EUR
IR-720-EUR
4308500
IR-730-EUR
IR-730-EUR
4308517
IR-750-EUR
IR-750-EUR
4308521
Temperature Meters
TMD-50
Technical specifications
K-type digital thermometer
with dual inputs
Display
Measurement range
Functions
Basic accuracy
±(0.1% v.M.+1°C)
±(0.1% v.M.+2°C)
±(0.1% v.M.+2°F)
±(0.1% v.M.+4°F)
Resolution
Power supply
Dimensions
Weight
• Temperature measurement with inputs for two
probes
• Measurement of temperature difference
Product information
TMD-50
Typ
Data
Hold
Typ
from -60°C to 1350°C
from -60°C to 200°C
from -76°F to 1999°F
from -76°F to -328°F
0.1 °C/°F
4 x battery 1.5 V, IEC R03, AAA
approx. 160 x 85 x 30 mm
approx. 280 g
Product highlights
• T1-T2 (temperature difference)
• Shock-proof and impact-resistant thanks to
standard protective holster
TMD-53
Typ
• Input for two type K temperature probes
• Switchable between °C and °F measurement
• Integrated measurement memory (data hold)
• MIN/MAX and relative value measurement
• Measuring the average temperature
• Illuminated display
• Auto Power Off
LCD, 3½ digit, 1999 digits
Type K -180...+1350° C
(-292...+1999° F)
TMD-53
TMD-53 specifications
K-type / J-type digital
thermometer with dual input
Display
Measurement range
as the TMD-50, also with:
• Connections for two temperature probes
(for types K and J)
• Alarm function (optical and acoustic)
• Clear multi-functional display for T1, T2 and
T1-T2 (temperature difference)
Basic accuracy
± (0.05% rdg. + 0.3°C)
± (0.05% rdg. + 0.7°C)
± (0.05% rdg. + 0.6°F)
± (0.05% rdg. + 1.4°F)
Resolution
Power supply
Dimensions
Weight
LCD, 5 digit, 99999 digits
Type K -180...+1350° C
(-292...+2462° F)
at -50°C to 1350°C
at -50°C to -200°C
at -58°F to 2498°F
at -58°F to -328°F
0.1 °C/°F
4 x battery 1.5 V, IEC R03, AAA
approx. 160 x 85 x 30 mm
approx. 280 g
Included with TMD-50/TMD-53:
1 x TMD-50 or TMD-53
2 x K-type wire probe
4 x battery 1.5 V, IEC R03, AAA
1 x user manual
Data
Hold
TMD-56
Technical specifications
Digital thermometer with data
logger and USB connection
Display
Measurement range
as the TMD-53, also with:
• Inputs for two temperature probes
(of types K, J, T, R/S, N and E)
• Built-in real-time clock and date
• Clear multi-functional display for date, time, T1,
T2 and T1-T2 (temperature difference)
• USB interface
• Evaluation software included
• Data logger for 16,000 measurement values
(various intervals can be selected)
Basic accuracy
Type K
± (0.05% rdg. + 0.3°C)
± (0.05% rdg. + 0.7°C)
± (0.05% rdg. + 0.6°F)
± (0.05% rdg. + 1.4°F)
Resolution
Power supply
Dimensions
Weight
LCD, 4½ digit, 19999 digits
Type K: -180°C to 1350°C
(-292°F to 2462°F)
at -50°C to 1350°C
at -50°C to -210°C
at -58°F to 2501°F
at -58°F to -346°F
0.1 °C/°F
4 x battery 1.5 V, IEC R03, AAA
approx. 160 x 85 x 30 mm
approx. 360 g
TMD-56
Typ
Typ
R/S,
N, E
Typ
Data
Hold
PC
data
logger
Accessories:
Carrying case
Model 1150
Heat-conducting paste
up to 250 °C (30 g)
Model 1032
Included with TMD-56:
1 x TMD-56
2 x K-type wire probe
1 x USB cable
1 x software CD
4 x battery 1.5 V, IEC R03, AAA
1 x user manual
Ordering Information:
Description
Model
TMD-50
TMD-50
TMD-53
TMD-53
TMD-56
TMD-56
Carrying case
1150
Heat-conducting paste 1032
Article no.
3730150
3730085
3730138
2145755
2145689
69
Environmental testing| Temperature meters/moisture meters
TPP1-C1
Mini pocket thermometer with
immersion probe
Functions
• Temperature measurement with integrated
NTC sensor
Product information
• Immersion probe
• Measurement memory (data hold)
• Compact design
• With protective sleeve/holder (TPP1-C1 only)
TPP2-C1
TPP2-C1
NTC
Typ
Data
Hold
Accessories:
Heat-conducting paste
up to 250 °C (30 g)
Model 1032
Mini pocket thermometer with
surface probe
Technical specifications
Display
Measurement range
Range
-50...-20° C
-19.9 ... +49.9° C
+50.0 ... +199.9° C
+200 ... +250° C
Temperature change/
response time
Probe dimensions
TPP1-C1
TPP2-C1
LCD, 3½ digit
-50 to +250°C
Resolution Accuracy
1° C
±3° C
0.1° C
±2° C
0.1° C
±(3 % rdg. + 1°C)
1° C
±(3 % rdg. + 1°C)
> 5 K/s
128 mm x Ø 3.8 mm
125 mm x Ø 13.7 mm
(tube Ø 3.8 mm)
1 x battery 3 V, IEC 2032
Power supply
Dimensions
(with protective sleeve): approx. 40 x 30 x 160 mm
Weight
approx. 16 g
• As TPP1-C1, but with:
Surface probe without protective sleeve
Included:
1 x TPP1-C1 or TPP2-C1
1 x battery 3 V, IEC 2032
1 x user manual
Ordering Information:
Description
Model
TPP1-C1
TPP1-C1
TPP2-C1
TPP2-C1
Heat-conducting paste 1032
TH-1
Digital humidity and
temperature meter
Functions
• Humidity measurement
• Temperature measurement
Product information
• Probe integrated in device
• Switchable between °C and °F measurement
• Integrated measurement memory (data hold)
• MIN and MAX data hold
• Auto Power Off
Product highlights
Article no.
2826634
2826652
2145689
Technical specifications
Display
Humidity
measurement
Measurement range
Resolution
Accuracy
Temperature
measurement
Measurement range
Resolution
Accuracy
Power supply
Dimensions
Weight
Dual LCD
0 to 100% rel. humidity
0.1%
± 3% rel. humidity
-20 to +50°C / -4 to +122°F
0.1°C / 0.1°F
± 0.6°C / ± 1F
1 x battery 3V, CR2032
175 x 42 x 16 mm
approx. 120 g
• Compact and handy design
• Dew point measurement
• Measurement of wet bulb temperature
NTC
Typ
Data
Hold
Included:
1 x TH-1
1 x battery 3 V, CR2032
1 x user manual
70
Ordering Information:
Description
Model
TH-1
TH-1
Article no.
3311871
Temperature meters/moisture meters
TH-3
Digital humidity and
temperature meter
Functions
• Humidity measurement
• Temperature measurement
Product information
• Probe integrated in device
• Switchable between °C and °F measurement
• Integrated measurement memory (data hold)
• MIN and MAX data hold
• Auto Power Off
Technical specifications
Display
LCD, 3½ digit
Humidity measurement
Measurement range
5...95% rel. humidity
Resolution
0.1%
Accuracy
± 3% rel. humidity
Response time
< 3 min.
Temperature measurement
Measurement range
-20…+60°C / -4…+140°F
Resolution
0.1°C / 0.1°F
Accuracy
± 0.8°C / ± 1.6°F
Response time
< 10 sec.
Power supply
1 x battery 9 V, IEC 6LR61
or 6F22
Dimensions
240 x 54 x 34 mm
Weight
approx. 180 g
Data
Hold
100 %
uncomfortable wet
THWD-3
Digital humidity and
temperature meter
80 %
As TH-3, but also with:
• Dew point measurement
• Measurement of wet bulb temperature
60 %
comfortable
40 %
rel. humidity
still comfortable
20 %
uncomfortable dry
0%
Included:
1 x TH-3 or THWD-3
1 x carrying case
1 x battery 9 V, IEC 6LR61
1 x user manual
Ordering Information:
Description
Model
TH-3
TH-3
THWD-3
THWD-3
Article no.
3027060
3033042
room temperature
MT-10
Moisture meters for construction
and timber
Functions
• Moisture meters for construction and timber
• Temperature measurement
Product information
• Probe integrated in device
• Switchable moisture measurement for timber
or construction materials
• Switchable temperature measurement in
°C or °F
• Back light
• Auto Power Off
Product information
• Compact and handy design
• Quick and simple statement regarding the
moisture content by means of 3 LEDs:
· green:
air-dry environment
· yellow:
increased moisture
· red:
excessive moisture
Included:
1 x MT-10
1 x battery 9 V, 6F22
1 x user manual
Technical specifications
Display
LCD, 3½ digit and 3 LEDs
Humidity measurement
Measurement principle of electric resistance
Measurement range
Timber
8…60%
Construction material 0.3…2.0%
Temperature
0…+40°C or +32…+99°F
Resolution
Timber
0.1%
Construction material 0.01%
Temperature
0.1°C / 0.2°F
Accuracy
Timber
±2%
Construction material ±0.1%
Temperature
±1°C / ±2°F
Power supply
1 x battery 9 V, 6F22
Dimensions
145 x 60 x 31 mm
Weight
approx. 100 g
Ordering Information:
Description
Model
Article no.
MT-10
MT-10
3503178
71
Environmental testing| Temperature and moisture meter,
carbon monoxide meter
TR200-A
Temperature / RH Data Logger
with Digital Display
Functions
• Temperature measurement
• Relative Humidity measurement
• Data Logger
Product information
PC
data
logger
Included:
1 x TR200-A
1 x user manual
1 x battery 3.0 V, IEC CR2
1 x USB cable
1 x CD with software (download suite)
• Wall mountable
• Offers visible LEDs warnings to monitor IAQ
condition
• Instrument for monitoring indoor temperature
and humidity
• Selection of save slots: 1000, 2000, 4000, 8000,
12000, 16000 max. per function
• Auto shutoff
• Can only be used via PC!
Product highlights
• USB interface
• IP65 rated for dust and moisture
• Optical limit value display
Accessories:
TPK-60, external temperature sensor
Model TPK-60
TR300
Temperature / RH Data Logger
with Digital Display
Functions
• Temperature measurement
• Relative Humidity measurement
• Data Logger
• Dew point display
Product information
PC
data
logger
Included:
1 x TR300
1 x user manual
4 x battery 1.5 V, IEC LR6
1 x USB cable
1 x CD with software (download suite)
• Instrument for indoor air quality monitoring
• Wall mountable, self-standing or tripod mountable
• Displays temperature, relative humidity
• Air Temperature or Dew Point (DP) display and
Celsius/Fahrenheit are selectable
• Offers visible LEDs warnings to monitor IAQ
condition
• Small size design
• Selection of save slots: 1000, 2000, 4000, 8000,
12000, 16000
Ordering Information:
Description
Model
TR200-A
TR-200-A
TPK-60
TPK-60
Article no.
3477302
3503184
Technical specifications
Display
Ranges
Temperature range
Relative Humidity
Tolerance
Temperature
Relative Humidity
Resolution
Temperature
Relative humidity
Power supply
Dimensions
Weight
LCD
-20…+70 °C
0…100 %
±0.6 °C at 0…50 °C;
otherwise ±1.2 °C
±3 % at 10…90 %; otherwise
±5 %
0.1 °C
0.1 %
4 x battery 1.5 V, IEC LR6
175 x 42 x 16 mm
approx. 200 g
Ordering Information:
Description
Model
Article no.
TR300
TR300
3311844
CM100
Technical specifications
• Adjustable threshold values: 25, 30, 35, 45, 50,
70, 100, and 200 ppm
• Display of measured value and maximum value
• Self-test function
• Auto Power Off
Display
LC display, 3 digit, 1000 digits
Measurement range/resolution
Carbon monoxide (CO) 0...999 ppm / 1 ppm
Accuracy
± 20% at 0 – 100 ppm
± 15% at 100 – 500 ppm
(at 20 °C +/-5%, 50 +/-20% RH)
Operating
temperature range
-10 ... +60°C (5...99% rel. humidity)
Power supply
3x batteries 1.5 V, IEC LR 03
(AAA), Micro
Dimensions
175 x 47 x 28 mm
Weight
approx. 130 g
Product highlights
Ordering Information:
• Monitoring carbon monoxide concentrations
with an alarm function
• Preset threshold value of 25 ppm for safe recognition of risks
Product information
72
LCD, 3¾ digit, 1999 digits
red: Hi-Lo Alarm: yellow Recording
Measurement ranges Temperature
Internal probe
-40 °C…+85 °C
External probe
-40 °C…+100 °C
Relative Humidity
0.0…99.9 %
Tolerance
Temperature
±0.6 °C (-20 °C…+50 °C);
otherwise ±1.2 °C
Relative Humidity
±3 % at 25 °C; otherwise 5 %
Resolution temperature 0.1 °C
Resolution RH
0.1 %
Save slots
1000, 2000, 4000, 8000, 12000,
16000
Power supply
1x battery 3.0 V, IEC CR2
Protection category
IP54
Dimensions
75 x 55 x 23 mm
Weight
approx. 200 g
• Real time marking (date/time)
• USB interface
• Extra large digital display
• Alarm function
Functions
1 x CM100
3 x batteries 1.5 V, IEC LR 03
1 x carrying case
1 x user manual
Display
LED display
Product highlights
carbon monoxide meter
Included:
Technical specifications
• Display of maximum carbon monoxide
concentration
• Illuminated display
Description
Model
Article no.
CM100
CM100
3311826
Temperature sensors / accessories
TPK-59
Type 101
flexible wire probe 4 mm plug
K-type surface probe
• with 4 mm plug (clearance 19 mm)
• Probe length approx. 0.9 m
K-type temperature sensor
Typ
Temperature range -46 °C…+316 °C
Accuracy
±1.5 °C
Typ
Temperature range -50 °C…+450 °C
Response time
approx. 5.5 s (63.2 % of final temperature value)
Accuracy
±1.5 °C
Connection cable
approx. 500 mm spiral cable
Dimensions
130 x 4 mm
Weight
approx. 115 g
Ordering Information
Ordering Information
Model: TPK-59 · Article no.: 2733660
Model: 5795 · Article no.: 2147199
TPK-60
Type 104
temperature probe
K-type liquid sensor
• 2.5 mm jack plug
• Fits the TR100-A and TR200-A
• Cable length 115 mm
• Temperature range
(see TR200-A on page 86)
Typ
Temperature range -50 °C…+1100 °C
Response time
approx. 12.0 s (63.2 % of final
temperature value)
Accuracy
±1.5°C (from 400 °C, 0.48 % rdg.)
Connection cable
approx. 500 mm spiral cable
Dimensions
130 x 3 mm
Weight
approx. 105 g
Ordering Information
Ordering Information
Model: TPK-60 · Article no.: 3503184
Model: 5794 · Article no.: 2147186
TPK-62
Type 106
2 x temperature probes with adapter
K-type immersion probe
• 4 mm jacks, connection for K-type probe
• Suitable for AM-540-EUR and AMP-550-EUR
•Temperature range
(see AM-540-EUR/AM-550-EUR on page 35)
Temperature range -50 °C…+600 °C
Response time
approx. 12.0 s (63.2 % of final
temperature value)
Accuracy
±1.5°C (from 400 °C, 0.48 % rdg.)
Connection cable
approx. 500 mm spiral cable
Dimensions
130 x 3 mm
Weight
approx. 105 g
Typ
Typ
Ordering Information
Ordering Information
Model: TPK-62 · Article no.: 4160703
Model: 5793 · Article no.: 3313234
TM-SWA
Type 110
K-type fast response surface probe
Data Logging Software and RS232
Cable for TMA10A
• Real-time software logs and displays data from all
measurement functions
• Record two channels simultaneously
• Air Flow and Temperature with TMA10 device
• Save results for subsequent analysis
• Automatic calculation of results including maximum,
minimum, average, and standard deviation
Typ
Temperature range -50 °C…+900 °C
Response time
approx. 2.3 s (63.2 % of final temperature value)
Accuracy
±1.5 °C (from 400 °C, 0.48 % rdg.)
Connection cable
approx. 500 mm spiral cable
Dimensions
130 x 8 mm
Weight
approx. 112 g
Ordering Information
Ordering Information
Model: TM-SWA · Article no.: 3027085
Model: 5797 · Article no.: 3313241
1032
Type 111
• Heat-conducting paste up to 250 °C (30 g)
• Contains silicone
Temperature range -50 °C…+400 °C
approx. 5.0 s (63.2 % of final temResponse time
perature value)
±1.5 °C
Accuracy
1000 x 2 mm
Dimensions
approx. 22 g
Weight
Heat-conducting paste
K-type flexible wire probe
Typ
Ordering Information
Ordering Information
Model: 1032 · Article no.: 2145689
Model: 5790 · Article no.: 3313229
73
Environmental testing| Light meters
93560
Digital light meter
with save function
Functions
• Illuminance measurement
Product information
• Automatic range selection
• Silicon sensor
• Integrated measurement memory (data hold)
Product highlights
• Measurement memory for 99 individual readings
Technical specifications
Display
Measurement ranges
(Auto range)
Resolution
of the display
Measurement ranges
Accuracy
Temperature drift
Power supply
Dimensions
Weight
Measure
0,1…
200000 Lux
Data
Hold
LCD, 4 digit
0…50 lx, 0…500 lx, 0…5000 lx,
0…50 klx, 0…200 klx
0.01 lx, 0.1 lx, 1 lx, 10 lx,
100 lx
0…5, 0…50, 0…500,
0…5000 fc,
0…20 kfc
< 10 %
< 1%/K
6 x battery 1.5 V, IEC LR03
150 x 72 x 35 mm (unit)
92 x 60 x 29 mm (sensor)
approx. 250 g
Measurement
Memory
Included:
1 x 93560
6 x battery 1.5 V, IEC LR03
1 x carrying case
1 x user manual
LM-100
Digital Lux Meter
Functions
Ordering Information:
Description
Model
Article no.
93560
93560
3222543
Technical specifications
Display
Measurement range
• Light measurement
Product information:
• Manual range selection
• Silicon sensor
• Integrated measurement memory (data hold)
• Max data hold (Max)
LM-120
Digital Lux Meter
Resolution
Accuracy
Power supply
Dimensions
Weight
LCD, 3½ digit
0…20 (only LM-120)
0...200, 2000, 20.000,
200,000 Lux
0–20, 200, 2000,
20,000 fc
0.1, 1, 10, 100 Lux
0.01, 0.1, 1, 10 Fc
< 10 %
1 x battery 9 V, IEC 6F22
130 x 63 x 38 mm (unit)
80 x 55 x 29 mm (sensor)
approx. 220 g
as the LM-100, also with:
• Automatic and manual range selection
• Minimum and maximum data hold (min/max)
• Auto Power Off
• Zero adjust knob
Measure
0,1…
200000 Lux
Data
Hold
Max
Hold
Included:
1 x LM-100 or LM-120
1 x battery 9 V, IEC 6F22
1 x carrying case
1 x user manual
74
Ordering Information:
Description
Model
LM-100
LM-100
LM-120
LM-120
Article no.
3052348
3052353
Leak detectors, sound level meters
TMULD-300
Ultrasonic leak detector kit
Technical specifications
Display
35 kHz...45 kHz ±6 dB
1 x battery 9 V, IEC 6LR61 (in any
case)
LED
Frequency
UT-300
40 kHz
Product information
Dimensions
ULD-300
UT-300
65 x 185 x 25 mm
65 x 165 x 25 mm
• Kit consisting of ultrasonic leak detector
(ULD-300) and ultrasonic transmitter (UT-300) in
robust carrying case
• Leaks indicated optically and acoustically
Weight
ULD-300
UT-300
approx. 150 g (incl. battery)
approx. 160 g (incl. battery)
Functions
• Pressurized air leaks (HGV pressurized air, braking and suspension systems), leaks in refrigeration, air-conditioning and heating systems, leaks
in steam lines etc.
• Leaks in door and window seals, roofs
• Leaks in the automobile sector:
Windscreens, door seals
ULD-300
Power supply
INFO:
Included:
1 x ultrasound leak detector ULD-300
1 x ultrasonic transmitter UT-300
1 x headphones
1 x extension and parabolic attachment
2 x batteries 9 V, IEC 6LR61
1 x carrying case
1 x user manual
Sounds above 20 kHz cannot be heard by the
human ear. Even the smallest leaks in pressurized
air and gas systems cause turbulences, which in
turn generate ultrasonic sounds.
The ULD-300 detects these sounds and pinpoints
the exact location of the leak. The ULD-300
indicates leaks optically (10-stage LED scale) and
acoustically (headphones) and features a thumb
wheel for setting the device's sensitivity.
Ordering Information:
Description
Model
Article no.
TMULD-300
TMULD-300 2731543
Ultrasonic transmitter (accessories)
UT-300
2734446
Accessories:
ULTRASONIC TRANSMITTER
Model UT-300
93517
Digital sound level meter with
save function
Functions
• Measurement of sound level for a comparison
with the guideline values for occupational safety (DGUV Regulation 6)
Product information
• Measurement according to frequency evaluation filters
A and C, with direct display in dB
• Maximum data hold (Max Hold)
• Switchable between fast and slow response
times
• Tripod connection
Technical specifications
Display
Measurement ranges
Resolution
Frequency range
Measurement accuracy
Response times
Recorder output
Power supply
Dimensions
Weight
LCD, 4 digit, bar graph
30...130 dB/0.1 dB
31.5 Hz…8 kHz
Class 2 in accordance with IEC
61672
FAST (125 ms), SLOW (1s)
AC: 1 Vrms at 5 kΩ,
DC: 10 mV/dB at 5 kΩ
1 x battery 9 V, IEC 6LR61
264 x 68 x 27 mm
approx. 260 g
Product highlights
Output
Analog
Measurement
Memory
Max
Hold
• DC and AC voltage output for connection to
spectrum analyzers, level recorders, or FFT analyzers
• Measurement memory for 99 individual readings
Included:
1 x 93517
1 x adjusting screwdriver
1 x 3.5 mm jack plug
1 x battery 9 V, IEC 6LR61
1 x carry case
1 x windbreak
1 x user manual
Ordering Information:
Description
Model
Article no.
93517
93517
3313290
75
Environmental testing| Sound level meter / calibrator
SM-10
Digital sound level meter
Functions
• Measurement of sound level
Product information
• Measurement according to frequency evaluation filters A and C, with direct display in dB
• Integrated measurement memory (data hold,
MAX)
• Switchable between fast and slow response
times
• Back light
Included:
Data
Hold
1 x SM-10
1 x battery 9 V, IEC 6LR61
1 x carrying case
1 x windbreak
1 x user manual
Max
Hold
SM-20A
Digital sound level meter
Functions
• Measurement of sound level
Product information
• Measurement according to frequency evaluation filters A and C, with direct display in dB
• Integrated measurement memory (data hold,
MAX)
• Switchable between fast and slow response
times
• Back light
Technical specifications
Display
LCD, 4 digit
Measurement range/resolution
A:
30…130 dB. / 0.1 dB
C:
35…130 dB. / 0.1 dB
Frequency range
31.5 Hz…8 kHz
Tolerance
±1.5 dB
Response times
Fast (125 ms); Slow (15 ms)
Power supply
1 x battery 9 V, IEC 6LR61
Dimensions
200 x 55 x 38 mm
Weight
approx. 230 g
Ordering Information:
Description
Model
Article no.
SM-10
SM-10
3052366
Technical specifications
Display
Measurement ranges
A:
C:
Tolerance
Frequency range
Power supply
Dimensions
Weight
LCD, 4 digit
30…30 dB. (resolution: 0.1 dB)
35…130 dB.(Resolution 0.1 dB)
±1.5 dB
31.5 Hz…8 kHz
1 x battery 9 V, IEC 6LR61
200 x 55 x 38 mm
approx. 230 g
Product highlights
• USB interface for PC connection
• Internal data logger for 14,000 readings
Included:
Data
Hold
Max
Hold
PC
data
logger
1 x SM-20A
1 x battery 9 V, IEC 6LR61
1 x interface cable
1 x software
1 x carrying case
1 x user manual
SM-CAL1
Sound level calibrator
Functions
• Calibrator for sound level meters
Product information
• Two selectable areas: 94 dB and 114 dB
• Appropriate for 1/2" microphones
Included:
1 x SM-CAL1
1 x 1/2” adapter
1 x battery 9 V, IEC 6F22
1 x user manual
76
Ordering Information:
Description
Model
SM-20A
SM-20A
Article no.
3477333
Technical specifications
Output signal
Accuracy
Frequency
Power supply
Dimensions
Weight
94 dB, 114 dB
± 0.5 dB
1 kHz (±4 %)
1 x battery 9 V, IEC 6F22
Ø 48 x 125mm
approx. 285 g
Ordering Information:
Description
Model
SM-CAL1
SM-CAL1
Article no.
3052382
Anemometer
TMA5
Technical specifications
Mini anemometer
Functions
• Air velocity measurement (m/s)
• Temperature measurement
• Humidity measurement
Product information
• Automatic range selection
• Integrated measurement memory (data hold)
• Auto power-off (can be deactivated)
Product highlights
• External temperature sensor can be connected
• Dew point measurement
• Measurement of wet bulb temperature
Data
Hold
Included:
1 x TMA5
1 x temperature probeTPK60
1 x battery 3.0 V, IEC CR 2032
1 x carrying case
1 x strap hanger
1 x user manual
Ordering Information:
Description
Model
Article no.
TMA5
TMA5
3503169
TMA10A
Anemometer
Functions
• Air velocity measurement (m/s)
• Airflow measurement (m3/s)
• Temperature measurement
Product information
Data
Hold
PC
• Integrated measurement memory (data hold)
• MIN/MAX and AVG value measurement
• Auto power-off (can be deactivated)
• Ideal for measurements in ventilation, air-conditioning and heating systems
• Flexible precision vane
Technical specifications
Display
LCD, 4 digit, 9999 digits
Measurement range (m/s)0.40–25.00 m/s
(resolution: 0.01 m/s)
Basic accuracy
±(3% rdg.)
Volume flow
0.01…99.99 m3/s
(Resolution 0.01 m3/s)
Temperature
0...50 °C or 32...122 °F
(Resolution 0.1 °F/°C)
Basic accuracy
± 1.5 °F / 0.8 °C
Power supply
1 x battery 9 V, IEC 6LR61
Dimensions
181 x 71 x 38 mm
Weight
approx. 360 g (incl. battery)
Product highlights
• RS-232 interface for PC connection
• TM-SWA software (optional)
Included:
Accessories:
TM-SWA data loggingsoftware and RS232 cable
Model TM-SWA
1 x TMA10A
1 x carry case
1 x battery 9 V, IEC 6LR61
1 x user manual
TMA-21HW
Hot-wire anemometer
Functions
• Air velocity measurement (m/s)
• Airflow measurement (m3/s)
• Temperature and humidity measurement
Product information
Data
Hold
Display
LCD, 3¾ digit, 3999 digits
Measurement ranges Air velocity
1.1...20.0 m/s
0.7...72.0 km/h
0.5...44.7 mph
60...3937 ft/m
0.4...38.8 KNT
1...8 BF
Basic accuracy
± 5% rdg or ± 5 digits
(the higher value applies)
Temperature (int.)
0°C...50°C
32°F...122°F
Resolution
0.1 °C/°F
Basic accuracy
± 1°C
Temperature (ext.)
-20°C...70°C
-4°F...158°F
Resolution
0.1 °C/°F
Basic accuracy
± 0.6°C
Humidity
5%...95% relative humidity
Resolution
0.1% relative humidity
Basic accuracy
± 3.5% relative humidity
Power supply
1 x battery 3.0 V, IEC CR 2032
Dimensions
136 × 46 × 17 mm
Weight
approx.135 g
PC
Included:
1 x TMA-21HW
1 x telescopic probe
1 x carry case
6 x battery 1.5 V, IEC LR03
1 x USB cable
1 x software on CD
1 x user manual
• Integrated measurement memory (data hold)
• MIN/MAX and AVG value measurement
• Auto power-off (can be deactivated)
• Ideal for measurements in ventilation, air-conditioning and heating systems
• Large, illuminated display
Ordering Information:
Description
Model
TMA10A
TMA10A
TM-SWA
TM-SWA
Article no.
2817785
3027085
Technical specifications
Display
LCD, 4 digit, 9999 digits
Measurement ranges (m/s) 0.1…30.0 m/s
(Resolution 0.1 m/s)
Basic accuracy
± (3% rdg.)
Volume flow
0.01…99.99 m3/s
(Resolution 1 m3/s)
Temperature
-20...60 °C
(Resolution 0.1 °C)
Basic accuracy
± 0.5 °C
Memory
512KB for 99 datasets
Power supply
6 x battery 1.5 V, IEC LR03
Dimensions
150 x 72 x 35 mm (unit)
Weight
approx. 300 g (incl. battery)
Product highlights
• USB interface for transferring stored measurements to a PC
• 1.2m telescopic probe simplifies measuring
• Integrated data logger for records over a longer
timeframe
Ordering Information:
Description
Model
TMA-21HW
TMA-21HW
Article no.
3730239
77
Environmental testing| Tachometers
TACH20
Digital tachometer
Functions
• Rotational speed measurement
• Surface speed measurement
• Length measurement
Product information
• Display of rotational speed
• Display of surface speed in m/min, ft/min and
in/min
• Display of length measurement in m, ft and inch
• Integrated measurement memory
• Display shows last, maximum or minimum value
• Optical (non-contact) or mechanical, adapter-based measurement
• Visible optical measurement performed using
infrared beam
• Auto power off after approx. 30 sec (data
remains saved)
Included:
Accessories:
1 x TACH20
1 x mechanical measurement adapter
1 x extension
2 x probes
2 x measuring wheel
10 x Reflex stickers
2 x batteries 1.5 V, IEC LR6
1 x case
1 x user manual
Reflex stickers
75 mm long (10 pcs.) Model 1154
TACH-10
Digital tachometer
Functions
• Rotational speed measurement
• Surface speed measurement
Product information
• Display of rotational speed
• Display of surface speed in m/min, ft/min and
in/min
• The last value is shown in the display
• Optical (non-contact) or mechanical, adapter-based measurement
• Visible optical measurement performed using
infrared beam
• Auto Power Off
Included:
1 x TACH-10
1 x measuring wheel
1 x roll of Reflex stickers
1 x battery 9 V, IEC 6LR61
1 x user manual
78
Accessories:
Reflex stickers
75 mm long (10 pcs.) Model 1154
Technical specifications
Display
Ranges
Rotational speed
Speed
Length
Tolerance
Measurement time
Measurement distance
Power supply
Dimensions
Weight
LCD, 5 digit
1 ... 99,999 1min
0.1 ... 1,999 m/min
0.02 … 99,999 m
± 0.2 %
± 0.02 % (rpm)
0.5 s/1 period at low
rpm
max. 350 mm
2 x battery 1.5 V, IEC LR6
180 x 60 x 25 mm
approx. 195 g
Ordering Information:
Description
Model
TACH20
TACH20
Reflex stickers
1154
Article no.
3311961
2145762
Technical specifications
Display
Ranges
Rotational speed
Speed
Tolerance
Measurement distance
Power supply
Dimensions
Weight
LCD, 5 digit
10 ... 99,999 1min
1.000 ... 9,999 m/min
± (0.1 % rdg. + 2 digits)
50-300 mm
1 x battery 9 V, IEC 6LR61
270 x 180 x 30 mm
approx. 550 g
Ordering Information:
Description
Model
TACH-10
TACH-10
Reflex stickers
1154
Article no.
3730008
2145762
Power and Energy
Measurement
Energy costs have been rising at increasing
speed for many years. For this reason, the
notion of energy efficiency is more relevant
than ever.
Using corresponding measuring equipment
means it is not just possible to measure and
document energy consumption, but it is also
possible to establish the potential savings
from your system.
Products
Power and energy measurement
80
79
Power and Energy Measurement
Power Analyzer PQ55A
3-phase power and energy analyzer
Functions
• Comprehensive real-time monitoring, recording
and analysis of 3-phase systems
• Voltage measurement (true RMS)
• Current measurement (true RMS)
• Power factor measurement
• Phase angle measurement
• Power analysis (active, apparent and reactive
power)
• 4. Current clamp for neutral line current measurement
• Suitable for use in housing construction, offices
and
small businesses
Product information
Included:
1 x PQ55A
4 x current clamps
4 x crocodile clips
4 x test leads
8 x battery 1.5 V, IEC LR6
1 x mains adapter
1 x RS-232 cable
1 x carry case
1 x PC software (English) for Windows 2000/XP/
Vista with in-depth manual (German)
1 x user manual
• Internal 512 kB data logger for long-term monitoring
• Internal measurement memory for max. 99 individual readings
• Multi-functional measured value display for all
input signals
• Power supply via batteries or external mains
adapter
• Current clamps 3…1000 A, jaw opening 40 mm
• Data transfer via optically isolated RS-232 interface
• Software for data analysis included
Technical specifications
Voltage measurement:
3 input channels with common reference point "N"
Measurement range
0…600 Vrms
Resolution
0.1 V
Accuracy
± (1 % rdg. + 10 D)
For voltages >80 V
Network frequency
50 Hz (excl. frequency inverter
operation)
Current measurement:
Measurement range
phase 1-3
3...1000 A
"N" measurement range 3...250 A
Resolution
0.1 A
Basic accuracy:
± (2.5% rdg. + 15 digits) ±1%
for currents > 3 A
Permissible overload 10 % (for sinusoidal currents)
Active power (P)
display range: 0–999.9 kW
Apparent power (S)
display range
0 to -999.9 kVA
Reactive power (Q)
display range
0–999.9 kVar
Power factor (PF)
display range
0 to +1
Phase angle
display range
0° to 90°
Frequency measurement (for voltage range >80 V)
Measurement range
45 ... 85 Hz
Phase sequence detection (for conductor voltages > 80 V)
Energy measurement (active, apparent and reactive power)
Accuracy
±(3.5 % rdg. + 20 digits)
Data logger
512 kB,
non-volatile memory
max. 20,000 readings,
max. 10 measurement series
max. 12,000 readings
per measurement series
Sampling rate
adjustable: 5 s, 30 s, 1 min,
2 min
Manual
measurement memory max. 99 readings
General information
Display
multi-functional LCD
Data transfer
via optically isolated RS-232 interface
Frequency range
42–63 Hz
Power consumption
approx. 10 VA
Pollution degree
2
Protection class
II
Protection category
IP 30
Measurement category CAT III/600 V
Safety cert.:
DIN VDE 0411/
EN 61010/IEC 61010
Power supply
8 x batteries 1.5 V, IEC LR6
Battery life
typ. 50 h
Mains adapter
Schuko 230 V/12…15 V, 300 mA
Environmental conditions
Operating temperature 0 °C to +50 °C
Storage temperature -10 °C to +60 °C
Dimensions
device (W x H x D)
235 x 117 x 54 mm
Weight (incl. battery) approx. 730 g
Ordering Information:
Description
Model
Article no.
Power Analyzer
PQ55A*
PQ55A
3037739
* only available for countries with Schuko plug
80
Measurement accessories
for a secure connection
Products
Measurement accessories
Cases
Replacement parts/fuses
82
88
89
The right measurement and testing
equipment, as well as the appropriate
measurement accessories are important
components for carrying out measurements
in a safe, reliable manner.
The following measurement accessories
contains various test leads, probes, and
crocodile clips. This ensures that any user
can find the necessary tools that is required
for their measurement task.
Replacement parts and fuses are listed on
page 103.
Symbols used in this chapter
Length of plug-in technology (e.g. 4 mm)
S
Silicone test lead
Touch protection
PVC test lead
CAT III
1000 V
Disclosure of measurement category in accordance with
EN 61010, DIN VDE 0411
Heat-resistant
16 A
Current-carrying capacity (e.g. 16 A)
Cold-resistant
81 81
Measuring accessories | Measuring accessories
Test leads SML 4W
4 mm safety plug-in technology
Accessory information
• Safety test lead, flexible 0.8 mm2
• Current-carrying capacity 16 A
• Measurement category CAT III / 600 V
Design
Ordering Information:
Description
Model
Article no.
Test lead ML 4W
red - 1000mm
307111
2146495
black - 1000mm
307121
2146508
red - 2000mm
307112
3313550
black - 2000mm
307122
3313561
• PVC insulation
• Two-way safety plugs with onward connection
capability in accordance with DIN VDE 0411/EN
61010/IEC 61010
600 V
16 A
Safety clamp-type test
probe SKP 41 set
4 mm plug-in technology
Ordering Information:
Model
370010
Article no.
2146701
Accessory information
• Approx. 155 x 49 mm
• Current-carrying capacity 2 A
• Measurement category CAT III/1000 V
Set, consisting of:
1 x SKP 41 gray/red
1 x SKP 41 gray/black
Design
• Spring wire grabber with flexible, insulated
shaft
• Safety clamp-type test probe with 4-mm
safety jack in accordance with DIN VDE 0411/
EN 61010/IEC 61010
CAT III
1000 V
2A
High current safety
clamp-type test probe
HCP 41 set
4 mm plug-in technology
Accessory information
• Approx. 160 x 60 mm
• Current-carrying capacity 10 A
• Measurement category CAT III/1000 V
Set, consisting of:
1 x HCP 41 gray/red
1 x HCP 41 gray/black
Design
• Safety clamp-type test probe with
4-mm safety jack in accordance with
DIN VDE 0411/EN 61010/IEC 61010
CAT III
1000 V
82
10 A
Ordering Information:
Model
370024
Article no.
2146758
Measuring accessories
Probes PSS set of 2
Accessory information
• Approx. 100 x 21 mm
• Current-carrying capacity 6 A
• Measurement category CAT III/1000 V
Ordering Information:
Model
370008
Article no.
2146694
Set, consisting of:
1 x probe PSS 2 gray/red
1 x probe PSS 2 gray/black
Design
• Safety probe with
4-mm safety jack in accordance with
DIN VDE 0411/EN 61010/IEC 61010
CAT III
1000 V
6A
Probes PSK set of 2
Ordering Information:
2 mm probe, short version
Model
Accessory information
370004
Article no.
2146675
• Approx. 102 x 10 mm
• Current-carrying capacity 16 A
• Measurement category CAT III/1000 V, CAT
IV/600 V (with cover)
• Measurement category CAT II/1000 V
(without cover)
Set, consisting of:
1 x probe PSK 2, gray/red (with cover)
1 x probe PSK 2 gray/black (with cover)
Design
• Safety probe with safety jack
4-mm and 2 mm stainless steel probe in accordance with
DIN VDE 0411/EN 61010/IEC 61010
CAT III
1000 V
CAT IV
600 V
16 A
TL-300
Test lead set with crocodile clips
(red, black, yellow), case, and
temperature probe
Technical specifications
Current-carrying capacity 10 A
Current-carrying capacity 10 A
Measurement Category
Probes
CAT IV/1000 V (with cover)
CAT II/1000 V (without cover)
Crocodile clips
CAT IV/600 V, CAT III/1000 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/IEC 61010
Temperature probes K-type flexible wire probe
4 mm plug (distance 19 mm)
Probe length
approx. 0.9 m
Temperature range
-20 °C…+250 °C
Accuracy
-20...0 °C: ±2.5 °C or ±1.5% rdg.
0...250 °C: ±1.1 °C or ±0.4% rdg.
Ordering Information:
Typ
CAT III
1000 V
CAT IV
600 V
10 A
Model
Article no.
TL-300
4588279
83
Measuring accessories | Measuring accessories
Safety crocodile clip
KS 4L set
Ordering Information:
Model
4 mm plug-in technology
370012
Article no.
2146712
Accessory information
• 94 x 42 mm
• Current-carrying capacity 16 A
• Measurement category CAT III/1000 V, CAT
IV/600 V
• Opening: approx. 24 mm
Set, consisting of:
1 x KS4L gray/red
1 x KS4L gray/black
Design
• Safety crocodile clip with
4-mm safety jack in accordance with
DIN VDE 0411/EN 61010/IEC 61010
CAT III
1000 V
CAT IV
600 V
16 A
Crocodile clips for
conductor rails
4 mm safety plug-in technology
Accessory information
Ordering Information:
Model
red
black
391511
391512
Article no.
2146861
2146877
• 155 x 40.5 mm
• Current-carrying capacity 5 A
• For conductor rails up to 30 mm
• Measurement category CAT III/600 V
• Opening: 0...20 mm/10...30 mm
Design
• Crocodile clip for secure measurement
on conductor rails
• 4 mm safety plug-in technology
CAT III
600 V
5A
Unidreh accessory set
4 mm plug-in technology
Accessory information
• Self-retaining probes with clamping range
ø 4...8 mm
• Safe contacting, e.g. in CEE 16 A- and
CEE 32 A sockets
• Crocodile clip included
Included:
3 x probes, black
1 x crocodile clip, black
1 x carrying case
Technical specifications
Current-carrying capacity 8 A
Measurement Category
Probes (Astaco)
CAT II/1000 V
Crocodile clip (KS4L)
CAT III/1000 V, CAT IV / 600 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Ordering Information:
Model
UNIdreh accessory set
1324
CAT II
1000 V
The solution for secure contacts with
CES sockets.
84
Article no.
2146183
Measuring accessories
Professional test lead
set for multimeters
2 mm safety probes
Accessory information
• Test lead set with
4 mm safety plug-in technology
• Ergonomic handle
• Silicone safety test lead
• Measurement category CAT IV / 1000 V
(with cover)
• Measurement category CAT II / 1000 V
(without cover)
• 2mm probes
Technical specifications
Current-carrying capacity max. 20 A
Measurement category CAT IV / 1000 V (with cover)
CAT II / 1000 V (without cover)
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Ordering Information:
Model
Professional test
lead set
1306
with silicone insulation
Article no.
3313458
Included:
CAT IV
1000 V
S
2 x test leads, approx. 1 m long,
2 covers
Professional test lead
set for multimeters
4 mm safety probes
Accessory information
• Test lead set with 4 mm safety plug-in
technology
• Ergonomic handle
• Silicone safety test lead
• Measurement category CAT IV / 1000 V
(with cover)
• Measurement category CAT II / 1000 V
(without cover)
• 4mm probes
Technical specifications
Current-carrying capacity max. 20 A
Measurement category CAT IV / 1000 V (with cover)
CAT II / 1000 V (without cover)
2
Pollution degree
DIN VDE 0411/EN 61010/
Safety cert.:
IEC 61010
Ordering Information:
Model
Professional test
1307
lead set
with silicone insulation
Article no.
2146176
Included:
CAT IV
1000 V
S
2 x test leads, approx. 1 m long,
2 x covers
Mini crocodile clips
2 mm plug-in technology (fits
all 2 mm multimeter probes)
Accessory information
Ordering Information:
Model
red
black
390450
390451
Article no.
2406492
2406509
• 41.5 x 13 mm
• Max. voltage 33 V AC / 70 V DC
• Opening: approx. 7 mm
Design
• Miniature crocodile clip
85
Measuring accessories | Measuring accessories
TL36A
Technical specifications
Accessory information
Measurement categories
Test lines CAT III/1000 V, CAT IV/600 V
(with cover)
CAT II / 1000 V
(without cover)
Current-carrying capacity 10 A
Crocodile clips
CAT III / 1000 V, CAT IV / 600 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Test lead set
with crocodile clips
2 mm safety probes
• Test lead set with 4 mm safety technology
• PVC-insulated leads
• Threaded test probes
• Crocodile clips with thread connection,
opening approx. 10 mm
CAT III CAT IV
1000 V 600 V
Included:
2 x test leads, approx. 1 m long, with covers
2 x crocodile clips
Included:
2 x test leads, approx. 1 m long,
with covers
2 x crocodile clips
Accessory information
• Test lead set with 4 mm safety technology
• 4 mm test probes
Included:
2 x test leads
2 x probes (with covers)
2 x crocodile clips
86
3034444
Accessory information
Test lead set
CAT IV
600 V
TL36A
Measurement categories
Test lines CAT III/1000 V, CAT IV/600 V
(with cover)
CAT II / 1000 V
(without cover)
Current-carrying capacity 10 A
Crocodile clips
CAT III / 1000 V, CAT IV / 600 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
EU-200
CAT III
1000 V
Article no.
Technical specifications
• Test lead set with 4 mm safety technology
• PVC-insulated leads
• Threaded test probes
• Safety crocodile clips with thread connection,
opening approx. 16 mm
CAT IV
600 V
Model
TL35B
Test lead set
with safety crocodile clips
2 mm safety probes
CAT III
1000 V
Ordering Information:
Ordering Information:
Model
Article no.
TL35B
3068232
Technical specifications
Measurement categories
Test leads
CAT III / 1000 V
Probes
CAT IV / 600 V, CAT III / 1000 V
(with cover)
CAT II / 1000 V
(without cover)
Current-carrying capacity 16 A
Crocodile clips
CAT III / 1000 V, CAT IV / 600 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Ordering Information:
Model
Article no.
EU-200
2745046
Measuring accessories
Safety set
Accessory information
• Test lead set with 4 mm safety technology
Included:
CAT III
1000 V
1 x safety test lead, red
1 x safety test lead, black
1 x probe, red, with cover
1 x probe, black, with cover
1 x crocodile clip, red
1 x crocodile clip, black
Electronics set
Accessory information
• Test lead set with 4 mm safety plug-in technology
Included:
CAT III
1000 V
1 x safety test lead, red, 16A
1 s safety test lead, black, 16A
1 x crocodile clip, red, 16A
1 x crocodile clip, black, 16A
1 x safety clamp-type test probe, red, 2A
1 x safety clamp-type test probe, black, 2A
1 x safety probe, red, 6A
1 x safety probe, black, 6A
Electrician set
Accessory information
• Test lead set with 4 mm safety plug-in technology
Included:
CAT III
1000 V
1 x safety test lead, red, 16A
1 s safety test lead, black, 16A
1 x safety probe, red, 6A
1 x safety probe, black, 6A
1 x safety clamp-type test probe, red, 10A
1 x safety clamp-type test probe, black, 10A
1 x crocodile clip, red, 16A
1 x crocodile clip, black, 16A
Technical specifications
Current-carrying capacity 16 A
Measurement Category
Safety test
leads
CAT III/1000 V
Probes
CAT III/1000 V, CAT IV / 600 V
(with cover)
CAT II / 1000 V
(without cover)
Crocodile clip
CAT III/1000 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Ordering Information:
Model
Safety set
370003
Article no.
2146666
Technical specifications
Current-carrying capacity 2A/6A/16A
Measurement Category
Safety test
leads
CAT III/1000 V
Probes
CAT III/1000 V
Crocodile clip
CAT III/1000 V
Clamp-type test probes CAT III/1000 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Ordering Information:
Model
Electronics set
370001
Article no.
3313577
Technical specifications
Current-carrying capacity 6A/10A/16A
Measurement Category
Safety test
leads
CAT III/1000 V
Probes
CAT III/1000 V
Crocodile clip
CAT III/1000 V
Clamp-type test probes CAT III/1000 V
Pollution degree
2
Safety cert.:
DIN VDE 0411/EN 61010/
IEC 61010
Ordering Information:
Model
Electrician set
370000
Article no.
2146653
87
Measurement accessories| Cases
1150
1175
CC-VP-7xx
Material: Nylon, upholstered, fasteners,
Lanyard
Internal dimensions: 200 x 150 x 40 mm
Material: Nylon, upholstered, belt loop
Internal dimensions: 295 x 80 x 50 mm
Material: Nylon, upholstered, fasteners,
Hand Strap.
Suitable for 2100 series (Alpha/Beta/Gamma)
and the VP-700 series
Internal dimensions: 280 x 80 x 45 mm
Model: 1150
Article no.: 2145755
Model: 1175
Article no.: 2145796
Model: CC-VP-7xx
Article no.: 3889931
1193
VC30A
VC221B
Material: Nylon, upholstered, fasteners,
Neck strap
Internal dimensions: 300 x 400 x 65 mm
Material: Imitation leather, carrying strap
External dimensions: 200 x 80 x 45 mm
Material: Imitation leather, carrying strap
External dimensions: 220 x 115 x 60 mm
Model: 1193
Article no.: 2145812
Model: VC30A
Article no.: 3068280
Model: VC221B
Article no.: 3068271
CC-ACDC
SV-U
Material: Nylon, carrying strap, belt loop
External dimensions: 300 x 120 x 60 mm
Material: Nylon, carrying strap, belt loop
External dimensions: 300 x 120 x 60 mm
Model: CC-ACDC
Article no.: 2732643
Model: SV-U
Article no.: 2733511
Carrying case
Professional carry case
Carrying case
88
Carrying case
Carrying case
Carrying case
Carrying case
Carrying case
Fuses
Fuses
Nominal
Feature
Nominal voltage
Dimensions
Packing unit
Item Number
500mA
fast-acting
1000V
6.3x32mm
4-pack, FP 500
1990695
500mA
fast-acting
500V
6.3x32mm
FP520
2156748
500mA
fast-acting
500V
6.3x32mm
3504681
500mA
fast-acting
1000V
6.3x32mm
2156753
630mA
fast-acting
500V
6.3x32mm
4223534
1A
fast-acting
600V
10x38mm
4223398
10A
fast-acting
600V
6.3x32mm
3814230
10A
fast-acting
500V
6.3x32mm
3504670
10A
fast-acting
1000V
10x38mm
11A
fast-acting
1000V
10x38mm
803293
12.5A
fast-acting
500V
6.3x32mm
2156681
15A
fast-acting
500V
6.3x32mm
2156727
2-pack, FP100
1990707
89
90
91
Appendix
Contents
Measurement categories
Index according to order no.
Index according to description
92
92
93
95
Appendix | Measurement categories
Things worth knowing
about measurement
categories, pollution
degree, labeling, and
symbols
Measurement categories:
Measurement category was referred to
as overvoltage category in an earlier
publication of DIN VDE 0411-1:1994.
0 – no measurement category:
Several types of testing and measurement circuits are not intended for direct
connection to the mains supply. These
are circuits, which are not directly connected to the mains, e.g. circuits within devices after the input transformer.
No standard values for overvoltage are
defined for such circuits.
CAT II - Measurement category II:
Operating or testing equipment that
is connected between the sockets and
the consumers. Only small overvoltages through lightning strikes have to be
taken into account for CAT II measurement category equipment, although
overvoltages caused by switching operations can arise. Short circuit currents of
up to 10kA must be expected. Examples
for operating equipment within this category include electrical equipment connected to sockets.
CAT III - Measurement category III:
Pollution Degree 1
Operating or testing equipment that is
connected between the energy meter
and the sockets. In the case of such
operating equipment, limited overvoltages can arise through lightning
strikes, and short circuit currents of up
to 50 kA must be expected. Examples
for operating equipment in this category includes building installations, fuses,
circuit breakers, residual current devices, switches, sockets, or permanently
installed operating equipment.
There is either no contamination, or only
dry contamination with no conductivity.
CAT IV - Measurement category
IV:
Pollution Degree 3
Operating or testing equipment that is
connected between the source of the
low-voltage network outside the building and the energy meter. Stronger
overvoltages and lightning strikes must
be taken into account with such operating equipment. Examples of operating
equipment belonging to measurement
category IV include cables in front of
the energy meter, service lines, overhead
lines, and underground cables. Short
circuit currents of over 50 kA must be
expected.
Pollution Degree
The insulation capability of measurement and testing equipment can be
severely reduced by surface contamination. Particles of dust and soot, or water
can create conductive connections and
considerably reduce the surface resistance of the insulation.
Measurement category
0
II
III
Supply of access cables
counter
Secondary building
counter
iburg
SC Fre
1.FC Köln
Pollution Degree 2
Usually, only non-conductive contamination is found. However, temporary conductivity due to condensation should be
expected on occasion.
Operation site, e.g. industrial, or in a
laboratory.
Either conductive contamination takes
place, or there is dry, non-conductive
contamination which becomes conductive due to condensation that is expected.
Operation site, e.g. heavy industry, construction sites, brief usage in the open
air.
Labeling and symbols
Warning of a hazardous area,
observe the instruction manual
Caution! Hazardous voltage, risk of
electric shock
Double or reinforced insulation in
accordance with Class II IEC 61140
(Protection class II)
Conformity mark, confirms adherence to the relevant guidelines and
regulations applicable to the respective equipment
Protection types
IV
Supply of
access
cables
This pollution has no effect.
Earth cable
DJK Heuweiler
In electronic measurement and test
devices, and other operating equipment, the protection against foreign
bodies (dirt) and water is indicated by
two digits after the short form IPxx. The
first digit can be from 0 to 6. This indicates the protection against the ingress
of foreign bodies. 0 indicates no protection, 6 indicates protection against the
ingress of dust. The second digit can be
from 0 to 8. This indicates the protection
against the ingress of water. 0 indicates
no protection, 8 indicates protection
against the ingress of water when submerged.
Secondary building
Supply of
access
cables
Transformer
counter
Earth cable
0
CAT II
CAT III
CAT IV
Other circuits that
are not directly
connected to
MAINS
Circuits connected
to MAINS socket
outlets, and similar
points in the
MAINS installation
MAINS
distribution parts
of the building
Source of the
MAINS installation
in the building
Protection Levels
Protection class I:
Protection via protective earth
Protection class II:
Protection via protective insulation
Protection class III:
Protection via safety extra-low voltage
93
Index according to order no.
1032
1063
1141
1142
1150
1154
1175
1193
1217
1226
1233
1235
1236
1237
1240
1241
1278
1279
1282
1289
1290
1304
1306
1307
1311
1312
1314
1316
1324
1325
1332
1338
1343
5790
5793
5794
5795
5797
9023
9050
9080
9085
9098
93517
93560
93570
307111
307112
307121
307122
370000
370001
370003
370004
370008
370010
370012
370014
370016
370024
390450
390451
391111
391121
391511
391512
1103D
15XP-B
2025-D
2032-D
94
Heat-conducting paste up to 250°C (30g)
Barcode sticker 54 x 15 mm (250 pcs.)
Test lead Commander 2 (for 9050)
Three-phase adapter
Carry case
Reflex sticker for TACH20
Carry case for 2100/2000 ALPHA/BETA/GAMMA
Professional carry case
USB adapter
AC current clamp adapter for 0100-EUROtest
Measurement adapter: Schuko/Schuko
Measurement adapter: CEE 5-pole, 16A
Measurement adapter: CEE 5-pole, 32A
Crimping tool
Three-phase adapter 16A
Three-phase adapter 32A
Test report in accordance with DIN VDE 0100
Test report in accordance with DIN VDE 0701/0702
Interface cable, 9-pole
Protocol set
Punch pliers
Marker tags (10 pcs.)
Professional test lead set with 2 mm silicone safety probes
Professional test lead set with 4 mm silicone safety probes
CHB1 Leakage current clamp adapter (AC)
Software es control professional 0100
Software es control professional 0701-0702/0113
Software es control professional Complete
UNIDREH accessory set
Barcode scanner for MACHINEmaster (9092, 9050)
Software for Hexagon 340 digital multimeter
Test report for DIN VDE0113 / EN 60204
VLP 5 Three-phase current extension test adapter
Type 111 thermal sensor, K-type flexible wire probe
Type 106 thermal sensor, K-type immersion probe
Type 104 thermal sensor, K-type liquid sensor
Type 101 thermal sensor, K-type surface probe
Type 110 thermal sensor, K-type fast response surface probe
TESTFIX continuity tester
MACHINEmaster machine and equipment tester
Schuko test FI/RCD (Socket tester with RCD/Fi trigger)
MT204-S machine tester in accordance with
DIN VDE 0113-1/EN 60204-1
GT-0751-CH medical equipment tester (Switzerland)
Sound level meter with save function
Light meter with save function
CHB5 Leakage current clamp with harmonics measurement TRMS
Test leads SML 4W 1000mm red
Test leads SML 4W 2000mm red
Test leads SML 4W 1000mm black
Test leads SML 4W 2000mm black
Electrician set
Electronics set
Safety set
Probes PSK set of 2
Probes PSS set of 2
Safety clamp-type test probe SKP 41 set
Safety crocodile clip KS 4L set
Measurement accessories 0100-SET black/blue/green
Measurement accessories MACHINE-SET red/black
High current safety clamp-type test probe HCP 41 set
Mini crocodile clip 2mm red
Mini crocodile clip 2mm black
Probes PSL 4 142mm gray/red
Probes PSL 4 142mm gray/black
Crocodile clips for conductor rails, 155mm red
Crocodile clips for conductor rails, 155mm black
UNITEST professional accessories
Digital multimeter
SF-1 Fuse finder
Cable locator set in case
69
59
68
61
69
78
88
88
64
59
60
60
60
72
61
61
72
56
29
72
72
*
85
85
57
64
64
64
84
59
29
72
60
73
73
73
73
87
13
59
54
59
71
75
74
46
82
82
82
82
87
87
87
83
83
82
98
*
*
82
85
85
*
*
84
84
*
*
27
21
2050-D
2052-D
2054-D
2100-ALPHA
2100-BETA
2100-GAMMA
MAGNO-VOLTfix contact-less voltage tester
VOLTfix plus contact-less voltage tester
VOLTfix Drill contact-less voltage tester
Voltage and continuity tester with phase sequence display/LED
Voltage and continuity tester with phase sequence display/LED-LCD
Voltage and continuity tester with phase sequence display/
LED-LCD 1000V
30XR-A-D
Digital multimeter
33XR-A-D
Digital multimeter
34XR-A-D
Digital multimeter
37XR-A
Digital multimeter
38XR-A
Digital multimeter
9072-D
Ohmtest continuity tester
93468-D
CHB15 Current clamp (AC/DC)
93469-D
CHB35 Current clamp (AC/DC) TRMS
93497-D
Hexagon 340A digital multimeter
93523-D
Hexagon 110 digital multimeter
93524-D
Hexagon 120 digital multimeter
93530-D
Insulation tester
AC50A-D
Digital leakage current clamp (AC)
AC68C
Current clamp 600A AC/DC TRMS with DMM
AC75B
Current clamp 600A AC, with DMM, temperature, capacitance
ACD-10 PLUS-D
Current clamp
ACD-14 TRMS-D
Current clamp 600A AC, TRMS, dual display
ACD-14-PRO-EUR
Current clamp with dual display
ACD-20SW
Swivel current clamp (AC)
ACD-23SW
Swivel current clamp (AC)
ACD-3300 IND
Current clamp 1000A AC TRMS, CAT IV industrial applications
ACD-45PQ
Power clamp meter 600 A AC TRMS
ACD-50NAV
Current clamp, TRMS, CAT IV
ACDC-100 (D)
Current clamp (AC/DC)
ACDC-100 TRMS-(D) Current clamp (AC/DC)
ACDC-3400 IND
Current clamp (AC/DC), TRMS, CAT IV
ACDC-400-(D)
Current clamp (AC/DC)
ACDC-52NAV
Current clamp (AC/DC), TRMS, CAT IV, 600A
ACDC-54NAV
Current clamp (AC/DC), TRMS, CAT IV, 1000A
ACF-6A
Adapter cable for current clamp
ADAPTER-PE
Adapter for protective earth
ADPTR-B15-EUR
Light Check Adapter B15
ADPTR-B22-EUR
Light Check Adapter B22
ADPTR-E14-EUR
Light Check Adapter E14
ADPTR-E27-EUR
Light Check Adapter E27
ADPTR-GU10-EUR Light Check Adapter BU10
ADPTR-KIT1-EUR
Light Check Adapter Kit EUR w/carrying case
ADPTR-PE-EUR
Socket Check Adapter Schuko PE
ADPTR-SCT-EUR
Socket Check Adapter Schuko
ADPTR-SCT-UK
Socket Check Adapter UK
AM-500-EUR
Digital multimeter
AM-510-EUR
Digital multimeter
AM-520-EUR
Digital multimeter
AM-530-EUR
Digital multimeter TRMS
AM-535-EUR
Digital multimeter Industry
AM-540-EUR
Digital multimeter
AM-550-EUR
Digital multimeter TRMS
AM-555-EUR
Digital multimeter Industry TRMS
AMP-210-EUR
AC current clamp 600A
AMP-220-EUR
Current clamp (AC/DC) 600A TRMS
AMP-25-EUR
Mini current clamp 300A AC/DC TRMS
AMP-310-EUR
AC current clamp 600A TRMS with rotary field measurement
AMP-320-EUR
Current clamp (AC/DC) 600A TRMS rotary field measurement
AMP-330-EUR
Current clamp (AC/DC) 1000A TRMS rotary field measurement
AMPRB-EU-01-A
Standard Kit
AMPRB-EU-02-A
Professional Kit
AMPRB-EU-03-A
Junior set A
AT-3500
Earth cable locator
AT-7000-RE
Receiver for AT-7000-EUR
AT-7000-TE
Transmitter with LCD for AT-7000-EUR
AT-7020-EUR
Cable locator set in case
AT-7030-EUR
Cable locator set in case with current clamp
BAT-250-EUR
Battery tester, BAT-250-EUR
BC-1250G
Barcode scanner for GT-800 and MT204-S
9
9
9
10
10
11
*
*
*
7
7
13
43
43
29
29
29
55
56
*
*
40
*
40
41
41
*
*
45
36
36
45
42
44
45
57
62
*
*
*
*
*
*
*
*
*
*
27
28
28
28
28
28
28
38
38
38
39
39
39
32
32
32
23
17
17
20
20
13
59
Appendix| Index according to order no.
BC233
BC-GT07XX
BR-7000-C
BR-7000-T
CC-7000-EUR
CC-ACDC
CC-VP-7XX
CM100
CT235A
CT237B
DAA-16
DAA-32
DGC-1000A
DL243D
DL248D
DL-SW-KIT
DM73C
DM78C
EU-200
EXT-MT204S
FTW00001339D
FTW00001341D
FTW00001342D
GT-0751
GT-400-CH
GT-400-D
GT-400-UK
GT-600
GT-800
GT-800-CH
HD110C
HD160C
HS-1
IR-450-EUR
IR608A
IR-710-EUR
IR-712-EUR
IR-720-EUR
IR-730-EUR
IR-750-EUR
KBGE-MT204S
LAN-1
LCR55A
LH41A
LM-100
LM-120
LT-10-ANT
LT-10-EUR
MANO2-A
MC-GT07XX
MLS55-3
MT-10
PA-1
PAT-BRUSH
PM-1
PM51A
PM55A
PQ55A
PRM-5-EUR
PRM-6-EUR
PROINSTALL-75-UK
PROINSTALL-100-CH
PROINSTALL-100-D
PROINSTALL-100-DK
PROINSTALL-100-EUR
PROINSTALL-200-CH
Barcode scanner for MACHINEmaster 9050
*
Barcode scanner RS-232, for application tester
GT-0701/0702, GT0751
59
Battery charger
20
Power pack for transmitter
20
Carry case for AT-7000-EUR
*
Carry case
88
Carrying case for VP-7xx series, 2000 and 2100 series
88
Carbon monoxide meters
72
Current clamp adapter (AC/DC)
47
Current clamp adapter (AC/DC)
47
Three-phase adapter 16A
61
Three-phase adapter 32A
61
Clamp meter for earth loop measurement
53
Test lead set, basic
*
Test lead set, deluxe
*
Software DOWNLOADER with interface cable
64
Pen-design digital multimeter
31
Pocket multimeter in protective case, Autorange
*
Test lead set with 4mm safety technology
86
Test lead extension 10 meters for MT204-S
*
Software package es control professional 0100 - Update
*
Software package es control professional 0701-0702/0113 - Update *
Software package es control professional Complete - Update
*
Medical applicance tester GT-0751
*
Appliance tester in with according DIN VDE 0701-0702 (Switzerland) 56
Appliance tester according DIN VDE 0701-0702
(Schuko plug,Germany, Austria)
56
Appliance tester according UK code of practice
00
Appliance tester according DIN VDE 0701-0702
(Schuko plug, Germany, Austria)
57
Appliance tester according DIN VDE 0701-0702
(Schuko plug, Germany, Austria)
57
Appliance tester according DIN VDE 0701-0702
(Schuko plug, Germany, Austria)
58
Multimeter for industrial applications
31
Multimeter heavy-duty TRMS multimeter, IP67, CAT IV
31
Hanging strap for transmitter
20
Infrared thermometer with flashlight, thermometer
67
Infrared thermometer
67
Infrared thermometer 10:1
68
Infrared thermometer 12:1
68
Infrared thermometer 20:1
68
Infrared thermometer 30:1
68
Infrared thermometer 50:1
68
Keyboard, USB German, for GT-800 and MT204-S
59
LAN-1, Wiring tester for LAN cable
23
LCR meter
27
Current clamp (AC/DC)
47
Light meter
74
Light meter, Autorange
74
Antenna for LT-10-EUR with carry case
11
Lamp tester with non-contact voltage recognition
11
Differential pressure manometer, with USB
*
Memory card (MMC/SD) for GT-07XX
*
Pipe transmitter for AT-3500
23
Moisture meters
71
Adapter for 3-pole plug
62
Brush probe
62
Test panel
*
Pocket multimeter
30
Pocket multimeter
30
Power Analyzer
80
Phase rotation indicator
14
Phase rotation indicator and motor rotation indicator
14
Installationtester (UK)
7
Installation testers in accordance with DIN VDE 0100/0105 (Switzerland) 52
Installation testers in accordance with DIN VDE 0100/0105
52
Installationtester (DK)
52
Installationtester EU (excl. UK, DACH, DK)
52
Installation testers in accordance with DIN VDE 0100/0105 (Switzerland) 52
PROINSTALL-200-D
PROINSTALL-200-EUR
PROINSTALL-CC
PROINSTALL-TL-CH
PROINSTALL-TL-D
PROINSTALL-TL-KIT
PROINSTALL-TL-UK
SC-3500
SC-7000-EUR
SF100-D
SM-10
SM-20A
SM-CAL1
SOLAR-100
SV-U
TACH-10
TACH20
TH-1
TH-3
THWD-3
TL-75
TL1500
TL-300
TL35B
TL36A
TL-7000-25M
TL-7000-EUR
TL73C
TL-EARTH
TL-GT07XX
TL-MT204S
TL-USB
TMA10A
TMA-21HW
TMA40-A
TMA5
TMD-50
TMD-53
TMD-56
TM-SWA
TMULD-300
TP73C
TPK-59
TPK-60
TPK-62
TPP1-C1
TPP2-C1
TR200-A
TR300
TX900
ULD-300
Zero-adapter
Installation testers in accordance with DIN VDE 0100/0105
Installationtester EU (excl. UK, DACH, DK)
PROINSTALL-CC, carrying case
PROINSTALL-TL-CH test lead (Switzerland)
PROINSTALL-TL-D test lead
PROINSTALL-TL-KIT, Test prod set
PROINSTALL-TL-UK, test lead (UK)
Current clamp for AT-3500
Current clamp for AT-7000-EUR
Fuse finder set
Sound level meter
Sound level meter
Sound level calibrator
Radiation measurement unit
Yellow carry case
Tachometer
Tachometer
Digital humidity and temperature meter
Digital humidity and temperature meter
Temperature and moisture meter with dew point measurement
Fused test probe (ProInstall-75)
Test lead set with crocodile clips (red/black)
Test lead set with safety crocodile clips
Test lead set with safety crocodile clips
Test lead set with crocodile clips
Test lead set, 25 meters, for AT-7000-EUR
Test lead set for AT-7000-EUR
Test lead with crocodile clip for DM73C
Earth measurement set
Measurement accessories set (test lead, probe, clip) and
USB cable for GT-07XX
Test lead 2 m, with probes for MT204-S
USB download cable for ProInstall 75/100/200
Anemometer
Hot wire anemometer
Anemometer
Mini anemometer
K-type thermometer with dual inputs
K/J-type thermometer with dual inputs
K/J/T/E-type thermometer with data logger and USB connections
Software and cable for TMA10A
Ultrasonic leak detector kit
Probe for DM73C
Flexible wire probe with 4 mm plug
Temperature probes for TR100-A and TR200-A
Temperature probes with adapter
Pocket thermometer with immersion probe
Pocket thermometer with surface probe
Temperature / RH data logger USB
Temperature / RH data logger USB
Microwave leak detector kit
Ultrasonic leak detector kit 89UT-300 Ultrasonic transmitter
Zero-adapter for ProInstall 75
52
52
*
*
*
*
*
23
20
*
76
76
76
15
88
78
78
70
70
71
*
*
83
86
86
20
*
*
52
*
*
52
77
77
*
77
69
69
69
73
75
*
73
73
73
70
70
72
72
*
75
*
*products in the portfolio but not shown in the catalog.
95
Index according to type description
AC current clamp 600A TRMS with rotary field measurement
Adapter cable for current clamp
Adapter for 3-pole plug
Adapter for protective earth
Anemometer
Anemometer
Antenna for LT-10-EUR, with carry case
Barcode scanner for GT-800 and MT204-S
Barcode scanner for MACHINEmaster (9092, 9050)
Barcode scanner for MACHINEmaster 9050
Barcode scanner RS-232, for equipment tester GT-0701/0702, GT0751
Barcode sticker 54 x 15 mm (250 pcs.)
Battery charger
Battery tester, BAT-250-EUR
Brush probe
Cable length meter 3000 (cable length measuring unit)
Cable locator set in case
Cable locator set in case
Cable locator set in case with current clamp
Carbon monoxide meters
Carry case for AT-7000-EUR
Carrying case
Carrying case
Carrying case
Carrying case for 2100/2000 ALPHA/BETA/GAMMA
Carrying case for VP-7xx series, 2000 and 2100 series
Carrying case, yellow SV-U
CHB1 Leakage current clamp adapter (AC)
CHB15 Current clamp (AC/DC)
CHB35 Current clamp (AC/DC) TRMS
CHB5 Leakage current clamp with harmonics measurement, TRMS
Clamp meter for earth loop measurement
Crimping tool
Crocodile clips for conductor rails, 155mm black
Crocodile clips for conductor rails, 155mm red
Current clamp (AC/DC)
Current clamp (AC/DC)
Current clamp (AC/DC)
Current clamp (AC/DC)
Current clamp (AC/DC)
Current clamp (AC/DC) 1000A TRMS rotary field measurement
Current clamp (AC/DC) 600A
Current clamp (AC/DC) 600A TRMS
Current clamp (AC/DC) 600A TRMS rotary field measurement
Current clamp (AC/DC), TRMS, CAT IV
Current clamp (AC/DC), TRMS, CAT IV, 1000A
Current clamp (AC/DC), TRMS, CAT IV, 600A
Current clamp 1000A AC TRMS, CAT IV industrial applications
Current clamp 600A AC, TRMS, dual display
Current clamp 600A AC, with DMM, temperature, capacitance
Current clamp 600A AC/DC TRMS with DMM
Current clamp adapter (AC/DC)
Current clamp adapter (AC/DC)
Current clamp adapter AC for 0100-EUROtest
Current clamp for AT-3500
Current clamp for AT-7000-EUR
Current clamp with dual display
Current clamp with dual display
Current clamp, TRMS, CAT IV
Differential pressure manometer, with USB
Digital humidity and temperature meter
Digital humidity and temperature meter
Digital leakage current clamp (AC)
Digital multimeter
Digital multimeter
Digital multimeter
Digital multimeter
Digital multimeter
Digital multimeter
Digital multimeter
Digital multimeter
Digital multimeter
96
AMP-310-EUR
ACF-6A
PA-1
ADAPTER-PE
TMA10A
TMA40-A
LT-10-ANT
BC-1250G
1325
BC233
BC-GT07XX
1063
BR-7000-C
BAT-250-EUR
PAT-BRUSH
2005
2032-D
AT-7020-EUR
AT-7030-EUR
CM100
CC-7000-EUR
1150
CC-ACDC
VC221B
1175
CC-VP-7XX
102
1311
93468-D
93469-D
93570
DGC-1000A
1237
391512
391511
ACDC-100
ACDC-100 TRMS-D
ACDC-400-D
LH41A
ACD-10 PLUS-D
AMP-330-EUR
AMP-210-EUR
AMP-220-EUR
AMP-320-EUR
ACDC-3400 IND
ACDC-54NAV
ACDC-52NAV
ACD-3300 IND
ACD-14 TRMS-D
AC75B
AC68C
CT235A
CT237B
1226
SC-3500
SC-7000-EUR
ACD-14 PLUS-D
ACD-14-PRO-EUR
ACD-50NAV
MANO2-A
TH-1
TH-3
AC50A-D
15XP-B
33XR-A-D
34XR-A-D
37XR-A
38XR-A
AM-510-EUR
AM-520-EUR
AM-540-EUR
30XR-A-D
39
58
62
62
77
*
11
59
59
*
59
59
20
13
62
*
21
20
20
72
*
88
88
88
88
88
58
43
43
46
53
*
84
84
36
36
42
47
40
39
38
38
39
45
45
44
*
*
*
*
47
47
59
23
20
*
40
44
*
70
71
46
*
*
*
7
7
28
28
28
*
Digital multimeter TRMS
AM-530-EUR
28
Digital multimeter TRMS
AM-550-EUR
28
Earth cable locator
AT-3500
23
Earth measurement set
TL-EARTH
59
Echometer 3000 (cable length measuring unit)
2006
*
Electrician set
370000
87
Electronics set
370001
87
Equipment tester in accordance with DIN VIN 0702-0702
GT-400-D
56
Equipment tester in accordance with DIN VIN 0702-0702 (Switzerland) GT-400-CH
56
Equipment tester in accordance with DIN VIN 0702-0702 (Switzerland) GT-600
57
Equipment tester in accordance with DIN VIN 0702-0702
with automatic operation
GT-800
58
Equipment tester in accordance with DIN VIN 0702-0702
with automatic operation (Switzerland)
GT-800-CH
58
Flexible wire probe with 4 mm plug
TPK-59
73
Fuse finder set
SF100-D
*
Hanging strap for transmitter
HS-1
20
Heat-conducting paste up to 250°C (30g)
1032
73
Hexagon 110 digital multimeter
93523-D
29
Hexagon 120 digital multimeter
93524-D
29
Hexagon 340A digital multimeter
93497-D
29
Hexagon 60 digital multimeter
HEX60-D
*
High current safety clamp-type test probe HCP 41 set
370024
82
Hot-wire anemometer
TMA-21HW
77
Infrared thermometer IR608A
81
Infrared thermometer 10:1
IR-710-EUR
68
Infrared thermometer 12:1
IR-712-EUR
68
Infrared thermometer 20:1
IR-720-EUR
68
Infrared thermometer 30:1
IR-730-EUR
68
Infrared thermometer 50:1
IR-750-EUR
68
Infrared thermometer with flashlight, thermometer
IR-450-EUR
67
Installation tester in accordance with DIN VDE 0100/0105
PROINSTALL-100-D
52
Installation tester in accordance with DIN VDE 0100/0105
PROINSTALL-200-D
52
Installation tester in accordance with DIN VDE 0100/0105 (Switzerland) PROINSTALL-100-CH 52
Installation tester in accordance with DIN VDE 0100/0105 (Switzerland) PROINSTALL-200-CH 52
Insulation tester
93530-D
55
Interface cable, 9-pole
1282
*
Junior set A
AMPRB-EU-03-A
32
K/J/T/E-type thermometer with data logger and USB connections TMD-56
69
K/J-type thermometer with dual inputs
TMD-53
69
Keyboard, USB German, for GT-800 and MT204-S
KBGE-MT204S
59
K-type thermometer with dual inputs
TMD-50
69
Lamp tester with non-contact voltage recognition
LT-10-EUR
11
LAN-1, Wiring tester for LAN cable
LAN-1
23
LCR meter
LCR55A
27
Light meter
LM-100
74
Light meter with save function
93560
74
Light meter, Autorange
LM-120
74
MACHINEmaster machine and equipment tester
9050
59
MAGNO-VOLTfix contact-less voltage tester
2050-D
12
Marker tags (10 pcs.)
1304
*
Measurement accessories 0100-SET black/blue/green
370014
*
Measurement accessories MACHINE-SET red/black
370016
*
Measurement accessories set (test lead, probe, clip) and USB cable for
GT-07XX TL-GT07XX *
Measurement adapter: CEE 5-pole 16A
1235
60
Measurement adapter: CEE 5-pole 32A
1236
60
Measurement adapter: Schuko/Schuko
1233
60
Medical equipment tester GT-0751
GT-0751
*
Medical equipment tester GT-0751-CH (Switzerland)
9098
59
Medium-sized carrying case
VC30A
88
Memory card (MMC/SD) for GT-07XX
MC-GT07XX
*
Microwave leak detector kit
TX900
*
Mini anemometer
TMA5
77
Mini crocodile clip 2mm black
390451
85
Mini crocodile clip 2mm red
390450
85
Mini current clamp 300A AC/DC TRMS
AMP-25-EUR
38
Mini current clamp 400A AC
AD40B
*
Mini current clamp 400A AC
AD40B-D
*
Moisture meters for construction and timber
MT-10
85
MT204-S Machine tester in accordance with DIN VDE 0113-1/EN 60204-1 9085
67
Multimeter for industrial applications
HD110C
37
Appendix | Index according to type description
Multimeter heavy-duty TRMS multimeter, IP67, CAT IV
Ohmtest continuity tester
Peak output and I-U curve analyzer for PV systems
Pen-design digital multimeter
Phase rotation indicator
Phase rotation indicator
Phase rotation indicator
Phase rotation indicator and motor rotation indicator
Pipe transmitter for AT-3500
Pocket multimeter
Pocket multimeter
pocket multimeter in protective case, Autorange
Pocket thermometer with immersion probe
Pocket thermometer with surface probe
Power Analyzer
Power clamp meter 1000 A AC TRMS, CAT IV, Navigator™
Power clamp meter 600 A AC TRMS
Power pack for transmitter
Probe for DM73C
Probes PSK set of 2
Probes PSL 4 142mm gray/black
Probes PSL 4 142mm gray/red
Probes PSS set of 2
Professional carry case
Professional Kit
Professional test lead set with 2 mm silicone safety probes
Professional test lead set with 4 mm silicone safety probes
PROINSTALL-CC, carrying case
PROINSTALL-TL-CH test lead (Switzerland)
PROINSTALL-TL-D test lead
PROINSTALL-TL-KIT, Test prod set
Protocol set
Punch pliers
Radiation measurement unit
Receiver for AT-7000-EUR
Reflex sticker for TACH20
Safety clamp-type test probe SKP 41 set
Safety crocodile clip KS 4L set
Safety set
Schuko measurement adapter for Telaris 0701/0702 (Switzerland)
Schuko test FI/RCD (Socket tester with RCD/Fi trigger)
SF-1 Fuse finder
Software and cable for TMA10A
Software DOWNLOADER with interface cable
Software es control professional 0100
Software es control professional 0701-0702/0113
Software es control professional Complete
Software for Hexagon 340 digital multimeter
Software package es control professional 0100 - Update
Software package es control professional 0701-0702/0113 - Update
Software package es control professional Complete - Update
Sound level calibrator
Sound level meter
Sound level meter
Sound level meter with save function
Standard kit
Swivel current clamp (AC)
Swivel current clamp (AC)
Tachometer
Tachometer
Temperature / RH data logger
Temperature / RH data logger
Temperature and moisture meter with dew point measurement
Temperature probes for TR100-A and TR200-A
Temperature probes with adapter
Test lead 2 m, with probes for MT204-S
Test lead Commander 2 (for 9050)
Test lead extension 10 meters for MT204-S
Test lead set for AT-7000-EUR
Test lead set with 4mm safety technology
Test lead set with crocodile clips
Test lead set with crocodile clips (red/black)
HD160C
9072-D*
SOLAR-4000
DM73C
DR100-D
DR705-D
PRM-5-EUR
PRM-6-EUR
MLS55-3
PM55A
PM51A
DM78C
TPP1-C1
TPP2-C1
PQ55A
ACD-53NAV
ACD-45PQ
BR-7000-T
TP73C
370004
391121
391111
370008
1193
AMPRB-EU-02-A
1306
1307
PROINSTALL-CC
PROINSTALL-TL-CH
PROINSTALL-TL-D
PROINSTALL-TL-KIT
1289
1290
SOLAR-100
AT-7000-RE
1154
370010
370012
370003
1296C
9080
2025-D
TM-SWA
DL-SW-KIT
1312
1314
1316
1332
FTW00001339D
FTW00001341D
FTW00001342D
SM-CAL1
SM-10
SM-20A
93517
AMPRB-EU-01-A
ACD-20SW
ACD-23SW
TACH-10
TACH20
TR200-A
TR300
THWD-3
TPK-60
TPK-62
TL-MT204S
1141
EXT-MT204S
TL-7000-EUR
EU-200
TL36A
TL1500
37
13
*
31
*
*
14
14
23
30
30
*
70
70
80
*
*
20
*
83
*
*
83
88
32
85
85
*
*
*
*
*
*
15
20
78
82
84
87
*
54
21
73
64
64
64
64
29
*
*
*
76
76
76
75
32
41
41
78
78
72
72
71
73
73
*
*
*
*
86
86
*
Test lead set with safety crocodile clips
Test lead set with safety crocodile clips
Test lead set, 25 meters, for AT-7000-EUR
Test lead set, basic
Test lead set, deluxe
Test lead with crocodile clip for DM73C
Test leads SML 4W 1000mm black
Test leads SML 4W 1000mm red
Test leads SML 4W 2000mm black
Test leads SML 4W 2000mm red
Test panel without equipment tester
Test report for DIN VDE0113 / EN 60204
Test report in accordance with DIN VDE 0100
Test report in accordance with DIN VDE 0701/0702
TESTFIX continuity tester
Three-phase adapter
Three-phase adapter 16A
Three-phase adapter 16A
Three-phase adapter 32A
Three-phase adapter 32A
Transmitter with LCD for AT-7000-EUR
Type 101 thermal sensor, K-type surface probe
Type 104 thermal sensor, K-type liquid sensor
Type 106 thermal sensor, K-type immersion probe
Type 110 thermal sensor, K-type fast response surface probe
Type 111 thermal sensor, K-type flexible wire probe
Ultrasonic leak detector kit
Ultrasonic leak detector kit
Ultrasonic transmitter
UNIDREH accessory set
UNITEST professional accessories
USB adapter
USB cable for ProInstall 100/200
VLP 5 Three-phase current extension test adapter
Voltage and continuity tester with phase sequence display/LED
Voltage and continuity tester with phase sequence display/LED-LCD
Voltage and continuity tester with phase sequence display/LED-LCD
TL35B
TL-300
TL-7000-25M
DL243D
DL248D
TL73C
307121
307111
307122
307112
PM-1
1338
1278
1279
9023
1142
DAA-16
1240
1241
DAA-32
AT-7000-TE
5795
5794
5793
5797
5790
TMULD-300
ULD-300
UT-300
1324
1103D
1217
TL-USB
1343
2100-ALPHA
2100-BETA
2100-GAMMA
86
83
20
*
*
*
82
82
82
82
*
56
56
56
32
61
61
61
61
61
20
73
73
73
73
73
70
70
70
84
*
64
52
60
10
10
11
*products in the portfolio but not shown in the catalog.
97
98
Your local partner:
Beha-Amprobe
In den Engematten 14
D-79286 Glottertal
Tel. +49 (0) 76 84 / 80 09 - 0
Fax +49 (0) 76 84 / 80 09 - 410
E-Mail: [email protected]
www.beha-amprobe.de
Specifications subject to change without notice. - 6007093-en
Beha-Amprobe
52 Hurricane Way
Norwich, Norfolk
NR6 6 JB United Kingdom
Tel. +44 (0) 1603 25 6662
Fax +44 (0) 1603 25 6664
E-Mail: [email protected]
www.beha-amprobe.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement