PSC-60 series
040-02-409-216-EH-0610.pdf
040-02-409-216-EH-0610
60W Single Output with Battery Charger(UPS Function)
PSC-60
series
Features :
Universal AC input / Full range
Optional L-Bracket and cover (PSC-60x-C, x=A,B)
Protections: Short circuit / Overload / Over voltage
Battery low protection / Battery polarity protection by fuse
Alarm signal for AC OK and Battery low
Cooling by free air convection
100% full load burn-in test
2 years warranty
SPECIFICATION
OUTPUT
OUTPUT NUMBER
CH1
CH2
CH1
CH2
DC VOLTAGE
13.8V
13.8V
27.6V
27.6V
RATED CURRENT
2.8A
1.5A
1.4A
0.75A
CURRENT RANGE
0 ~ 4.3A
--------
0 ~ 2.15A
--------
RATED POWER
59.34W
RIPPLE & NOISE (max.) Note.2 120mVp-p
CH1: 12 ~ 15V
VOLTAGE TOLERANCE Note.3 1.0%
--------
0.5%
--------
0.5%
--------
Note.5 800ms, 50ms/230VAC
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms/230VAC
90 ~ 264VAC
FREQUENCY RANGE
47 ~ 63Hz
1600ms, 50ms/115VAC at full load
10ms/115VAC at full load
127 ~ 370VDC
84%
EFFICIENCY (Typ.)
84%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
1.6A/115VAC
1A/230VAC
COLD START 30A/115VAC
60A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC
OVERLOAD
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
CH1:14.49 ~ 18.63V
CH1:28.98 ~ 37.26V
BATTERY CUT OFF
Protection type : Hiccup mode, recovers automatically after fault condition is removed
21 1V
10.5 0.5V
AC OK
TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. [email protected] 50VDC
BATTERY LOW
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. [email protected] 50VDC
DIMENSION
PACKING
Battery low voltage : < 22V
Battery low voltage : < 11V
-20 ~ +70 (Refer to output load derating curve)
20 ~ 90% RH non-condensing
-20 ~ +85
, 10 ~ 95% RH
0.03%/ (0~50 ) on CH1 output
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1 approved
I/P-O/P:3KVAC
I/P-FG:1.5KVAC
O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25
EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) Class B
Compliance to EN61000-3-2,-3
HARMONIC CURRENT
EMS IMMUNITY
MTBF
NOTE
--------
LOAD REGULATION
VIBRATION
OTHERS
--------
0.5%
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
(Note 4)
--------
CH1: 24 ~ 29V
1.0%
--------
WORKING TEMP.
EMC
240mVp-p
0.5%
OVER VOLTAGE
SAFETY &
--------
LINE REGULATION
PROTECTION
FUNCTION
59.34W
VOLTAGE ADJ. RANGE
SETUP, RISE TIME
INPUT
PSC-60B
PSC-60A
MODEL
/ 70% RH
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN55024, light industry level, criteria A
589.7K hrs min. MIL-HDBK-217F (25 )
PCB:101.6*50.8*29mm (L*W*H) ; with optional CASE:103.4*62*37mm (L*W*H)
PCB:0.13Kg; 96pcs/13.5Kg/0.89CUFT ; with optional CASE:0.29Kg; 45pcs/14Kg/0.67CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
6. Heat sink HS1,HS2 can not be shorted.
7. Heat sink HS1 must have safety isolation distance with system case.
File Name:PSC-60-SPEC 2010-05-24
040-02-409-216-EH-0610.pdf
040-02-409-216-EH-0610
PSC-60
60W Single Output with Battery Charger(UPS Function)
Mechanical Specification
series
Unit:mm
101.6
3.175
95.25
3.175
Optional cover:
No.998A -T
HS2
50.8
44.45
FS1
3
2
1
AC FUSE
T2.5A/250V
SVR1
1
2
3
4
5
6
CN1
CN2
HS1
3 max.
29
4- 3.3
18
14.5
1.HS1,HS2 can not be shorted.
2.HS1 must have safety isolation distance with system case.
4.2
AC Input Connector (CN1) : JST B3P-VH or equivalent
Assignment
AC/N
No Pin
AC/L
Mating Housing
JST VHR
or equivalent
Terminal
2-M
Optional L-Bracket:
No.998A -D
JST SVH-21T-P1.1
or equivalent
12.
7
Assignment
Bat. Low
AC OK
Battery -
95
3L
2-
Pin No. Assignment
Battery +
4
DC Output +
5
6
DC Output COM
2-M
Mating Housing
JST VHR
or equivalent
=4
3
78
DC Output Connector (CN2) : JST B6P-VH or equivalent
Pin No.
1
2
3
2-M
Terminal
10
JST SVH-21T-P1.1
or equivalent
3.4
3L
3.5
37
Pin No.
1
2
3
=4
55
30.
24
.2
85
62
Block Diagram
AC OK
Bat. Low
ALARM
CIRCUIT
I/P
EMI
FILTER
RECTIFIERS
&
FILTER
POWER
SWITCHING
RECTIFIERS
&
FILTER
DETECTION
CIRCUIT
FG
O.L.P.
CONTROL
O.V.P.
+V
-V
Bat. +
Bat. Battery Charger
&
Back Up Control
File Name:PSC-60-SPEC 2010-05-24
040-02-409-216-EH-0610.pdf
040-02-409-216-EH-0610
PSC-60
60W Single Output with Battery Charger(UPS Function)
series
Output Derating VS Input Voltage
Output Derating
Ta=25
100
100
PCB only
90
80
For PCB with
L-Bracket+cover option
80
70
LOAD (%)
LOAD (%)
60
40
20
-20
0
10
20
30 35 40
50
60
60
50
40
70 (HORIZONTAL)
90
95
100
115
120
140
160
180
200
220
240
264
INPUT VOLTAGE (VAC) 60Hz
AMBIENT TEMPERATURE ( )
Suggested Application
1.Back up connection for AC interruption
(1) Please refer to the Fig1.1 for suggested connection.
The power supply charge the battery and provide energy to the load in the same time when the AC main is OK.
The battery start to supply power to the load when the AC main fails.
+
A : 12V
B : 24V
Battery
BatBat+
DC+
DC-
+
-
Load
Fig 1.1 Suggested system connection
2.Alarm Signal for AC OK and Battery Low
(1) Alarm Signal is sent out through " AC OK " & " Battery Low " pins.
(2) An external voltage source is required for this function. The maximum applied voltage is 50V and the maximum sink current is 30mA.
(3) Table2.1 explain the alarm function built-in the power supply
Function
AC OK
Battery
Low
Output of alarm
Description
The signal is "Low" when the power supply
turns on
Low
(0.3V max. at 30mA)
The signal turns to be "High" when the power
supply turns OFF
High or open(External applied
voltage 30mA max.)
The signal is "Low" when the voltage of
battery is under A:11V, B:22V
Low
(0.3V max. at 30mA)
The signal is "High" when the voltage of
battery is above A:11V, B:22V
High or open(External applied
voltage 30mA max.)
Table 2.1 Explanation of Alarm Signal
AC OK (Battery low)
R
V
Pin6 DC output com
External voltage and R
(The max. Sink is 30mA and 50V)
Fig 2.2 Internal circuit of AC OK (Battery Low)
File Name:PSC-60-SPEC 2010-05-24
Headquarter Switzerland:
Pewatron AG
Thurgauerstrasse 66
CH-8052 Zurich
Phone +41 44 877 35 00
[email protected]
Office Germany:
Pewatron AG
Neumarkter Straße 86a
D-81673 Munich
Phone +49 89 260 38 47
[email protected]
We are here for you. Addresses and Contacts.
Sales Switzerland & Liechtenstein
Sales International Key Accounts
Postcode 3000 – 9999
Postcode 1000 – 2999
Basil Frei
Pewatron AG
Thurgauerstrasse 66
CH-8052 Zurich
Eric Letsch
Pewatron AG
Thurgauerstrasse 66
CH-8052 Zurich
Peter Felder
Pewatron AG
Thurgauerstrasse 66
CH-8052 Zurich
Phone + 41 44 877 35 18
Mobile + 41 76 279 37 26
Phone + 41 44 877 35 14
Mobile + 41 76 491 66 70
Phone + 41 44 877 35 05
Mobile + 41 79 406 49 83
[email protected]
[email protected]
[email protected]
Sales Germany
Postcode 00000 – 31999
Postcode 38000 – 39999
Postcode 80000 – 99999
Postcode 32000 – 37999
Postcode 40000 – 79999
Sales Austria
Kurt Stritzelberger
Pewatron AG
Neumarkter Straße 86a
D-81673 Munich
Gerhard Vetter
Pewatron AG
Fürstenbergstraße 12
D-55422 Bacharach-Medenscheid
Kurt Stritzelberger
Pewatron AG
Neumarkter Straße 86a
D-81673 Munich
Phone + 49 89 260 52 80
Mobile + 49 171 803 41 35
Phone + 49 674 394 75 75
Mobile + 49 163 762 74 30
Phone + 49 89 260 52 80
Mobile + 49 171 803 41 35
[email protected]
[email protected]
[email protected]
Pressure Sensors
Gas sensors / Gas sensor modules
Load cells
Linear position sensors
Angle sensors
Philipp Kistler
Phone + 41 44 877 35 03
[email protected]
Thomas Clausen
Phone + 41 44 877 35 13
[email protected]
Eric Letsch
Phone + 41 44 877 35 14
[email protected]
Accelerometers
Power supplies
Current sensors
Eric Letsch
Phone + 41 44 877 35 14
[email protected]
Sebastiano Leggio
Phone + 41 44 877 35 06
[email protected]
Sebastiano Leggio
Phone + 41 44 877 35 06
[email protected]
Drive technology
CH Postcode 5000 – 9999 / DE
Drive technology
CH Postcode 1000 – 4999 / AT / IT / FR
Roman Homa
Mobile + 41 79 444 00 86
[email protected]
Christian Mohrenstecher
Mobile +41 76 444 57 93
[email protected]
Sales Other Countries / Product Management
Competitive sensor & power supply solutions worldwide
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement