Designed, Manufactured and Supported in the USA
VIKING
PRODUCT MANUAL
S E C U R I T Y & C O M M U N I C A T I O N S O L U T I O N S
K-1275-IP Series
VoIP Entry Phone System with Built-In Proximity Card
Reader and Color Camera
November 7, 2016
Vandal Resistant VoIP Entry Phone System with Built-In Directory,
Proximity Card Reader, 12 Button Auto Dialer, and Analog Video Camera
The K-1275-IP is a durable and attractive hands-free phone for apartment and residential door entry applications requiring a vandal resistant VoIP speaker phone with an integrated 125 KHz Proximity Card
Reader and analog Color Video Camera. The K-1275-IP phone is designed to provide quick and reliable hands-free communication for SIP VoIP phone systems or cloud based service providers. The unit can be programmed from any PC on the same LAN or remotely using a Static IP Address. The K-1275-IP entry phone can dial up to 12 programmable numbers and another 12 rollover numbers. The brushed stainless steel faceplate has a built-in 12 resident directory with a waterproof, scratch resistant lens and 12 buttons for single push auto-dialing of a tenant’s phone number or business extension.
When the K-1275-IP phone is connected to an apartment or business tenant, a built-in contact closure may be activated to control an electric gate or door strike. Up to 1,000 keyless entry codes may be programmed, providing tenants with keyless entry. The K-1275-IP has a built-in Proximity Card Reader with capacity to program up to 1,000 card numbers. Keyless entry codes and card numbers can be programmed to only allow access at specific times and/or day of the week. The K-1275-IP includes a request for exit (REX) input and also offers event logging with time and date stamp.
The K-1275-IP-EWP shares all of the features of the K-1275-IP in addition to Enhanced Weather Protection
(EWP) for outdoor installations where the unit is exposed to precipitation or condensation. EWP products feature foam rubber gaskets and boots, sealed connections, gel-filled butt connectors, as well as urethane or thermal plastic potted circuit boards. For more information on EWP, see DOD# 859.
!
K-1275-IP
“Brushed 316 Stainless Steel”
(similar to brushed nickel)
K-1275-IP
(shown in optional VE-5x10-SS surface mount box)
Installation requires the assistance of a
Network Administrator / IT Technician.
Features
• Built-in high resolution analog NTSC color video camera with wide viewing angle, tilt/swivel adjustments and wide operating temperature: -40°F to 140°F
• Built-in 125KHz 26-bit Wiegand proximity card reader with LED and beep card read confirmation and EWP board protection
• Vandal Resistant Features: 14 gauge louvered 316 stainless steel faceplate with permanent laser etched graphics. Speaker/mic screen. Heavy duty metal keypad buttons and T-10 Security Torx drive mounting screws.
• Weather Resistant Features: Marine grade 316 stainless steel faceplate and screws. Keypad internally sealed per IP67. Mylar speaker. Self-draining mic mount. Faceplate, mic and speaker gaskets.
• Two sets of SPDT 2 Amp relay contacts for door/gate or camera control
• Optional RC-4A for Secure Remote Relay Control, see DOD# 582
• Blue “Call /Status” LED indicator
• SIP compliant (see pg 2 for list of compatible IP-PBX phone systems)
• PoE powered (class 2, <6.5 watts)
• Automatic Noise Canceling (ANC) feature for operation in noisy environments
• Viking’s proprietary VOX switching eliminates the need for “Push to Talk” mode
• Network downloadable firmware
• Programmable to speed dial up to 12 numbers
• Cycles to roll over phone number on busy or no-answer
• Program up to 1,000 keyless entry codes and/or proximity card numbers
• Keyless entry codes and proximity card numbers can be programmed to only allow access at specific times and day of week
• Event logging with time and date stamp
• Optional Enhanced Weather Protection (EWP), EWP products are designed to meet IP66 Ingress Protection Rating, see DOD# 859
• Hangs up on busy signal, time-out or touch tone command
• Remotely programmable
• Extended temperature range (-40°F to 140°F)
• Programmable volume adjustments for microphone and speaker
• Selectable auto-answer feature for monitoring
• Zinc plated steel rough-in box included
• Optional LRR-4 Long Range RFID Reciever, see DOD #226
• Optional VE-5x10 Surface Mount Box available, see DOD #424
• Optional VE-LIGHT kit to illuminate the front panel at night, see DOD# 428
• Self diagnostics (testing: com, mic, speaker, and switch)
Applications
• Residential Gate Entrance
• Courtesy Assistance Phone
• Customer Service Phone
• Automated Teller (ATM) Phone
• Kiosk Phone with up to
12 number speed dialing
• Door Entry Phone
• Apartment Entry Phone
• Use with LRR-4 Long Range RFID Transmitter DOD# 226
• Use with any of Viking’s Proximity Credentials: PRX-C, PRX-C-
ISO, PRX-FOB, and LRT-4 see DOD# 198 and 226.
www.vikingelectronics.com
Specifications
Power: PoE class 2 (<6.5 watts)
Dimensions: Overall: 5” x 10” x 2.5” (127mm x 254mm x 63.5mm)
Rough-in box: 4.5” x 9.12” x 2.5” (114mm x 232mm x 64mm)
Shipping Weight: K-1275-IP 4.4 lbs (2.0 kg), K-1275-IP-EWP 4.6 lbs (2.09 kg)
Operating Temperature: -40°F to 140°F (-40° C to 60° C)
Humidity - Standard Products: 5% to 95% non-condensing
Humidity - EWP Products: Up to 100%
Audio Codecs: G711u, G711a, G722
Network Compliance: IEEE 802.3 af PoE, SIP 2.0 RFC3261, 100BASE-TX with auto cross over
Connections: (1) RJ45 10/100 Base-T, (14) gel-filled butt connectors
Viking VoIP SIP System Compatibility List
NOTE: Exclusion from this list means only that compatibility has not been verified, it does not mean
incompatibility.
For detailed configuration instructions for certain vendors below, see Configuring Viking VoIP Phone
and SIP Servers, DOD# 944.
Vendor
3COM VCX
3CX
Aastra
Asterisk
Atcom
Avaya Aura Communication Manager
Avaya IP Office
BlueBox
Brekeke
Callcentric
Cisco Unified Communications Manager (CUCM)
Cisco Unified Communications Manager Express
(CUCME)
Elastix
Freeswitch
Grandstream
Interactive Intelligence iPECS (Ericsson-LG) iptel.org
Kamailio
MetaSwitch
NEC
OfficeSIP
OpenSIPS
Panasonic** (with SIP Extension Card)
Samsung Communications Manager (SCM)
ShoreTel*
Siemens Communications Server (SCS)
SIP Express Router (SER) sip.antisip.com
Snom PBX
Sonus
Switchvox
Teksip
Toshiba
VoIP.ms
Softswitch
X
X
X
X
X
PBX
Infrastructure Class
Proxy
SBC
(session border controller)
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Service
Provider
X
X
X
X
X
X
* Note: Not compatible with ShoreTel Ring Group/Hunt Group (unit can be programmed to ring an extension 2 or 3 times then roll to the next number, for a total of 5 numbers).
** Note: Relay operation commands are Not compatible with Panasonic Phone Systems (Panasonic does not transmit DTMF between station ports).
Known Incompatible System or Service Provider: Ring Central (Requires Authorization ID and Proxy address).
2
Camera Specifications
Image Sensor: 1/4” color CMOS
Video Output: 1 VP-P composite, NTSC, 75 ohms
Resolution: 420 lines (640 x 480 @ 30fps / 307,200 pixels)
Sensitivity: 0.025 LUX (50 IRE) F 1.2 3200K
Lens: 2.1mm, conical pinhole
FOV (Field of View): 80° Horizontal, 60° Vertical, 100° Diagonal
Tilt/Swivel Adjustment: Vertical +/- 20°, horizontal +/- 30° (see Diagram A)
IR Compatibility: This camera is equipped with an OLP (Optical Low Pass) filter to maintain correct video color in outside applications. The standard camera is NOT compatible with IR illuminators. If IR illumination is required, you will need to replace the existing camera with a Viking model VCAM-1IR. For more information, see DOD# 190.
Maximum Wire Run Length: 1000 ft with *RG59/RG6 for video and CAT5 for power (1 pair) and entry phone audio (1 pair). 150 ft with CAT5E for video, power and entry phone audio (longer video runs are possible by using video balun transceivers.
* Note: RG59 or RG6 with solid center conductor and 95% bare copper braid shield.
Diagram A
Camera Horizontal Field of View:
Rotate
Left 30°
80° Lens FOV
Rotate
Right 30°
Camera Lens
Proximity Card Reader Specifications
Power: PoE powered from K-1275-IP PCB
Maximum Cable Length: 500 ft 24 Awg stranded shielded (Belden 9537)
Frequency: 125KHz
Format: 26 bit Wiegand
Read Range: 1.25” to 2.0”
Technologies Supported: Viking PRX-C, PRX-C-ISO, PRX-FOB, LRT-4, certain legacy
HID® proximity protocols* and certain AWID 125Khz proximity protocols**
Transducer: Beeps during card read
LED: Red, turns off during card read
Humidity: Up to 100% (fully potted EWP)
Operating Temperature: -34° C to 65° C (-30° F to 150° F)
* HID and the HID logo are registered trademarks of HID Global Corporation, an ASSA
ABLOY company. All other trademarks are the property of their respective owners.
** AWID is a trademark of Applied Wireless Identification Group.
Definitions
Client: A computer or device that makes use of a server. As an example, the client might request a particular file from the server.
DHCP: Dynamic Host Configuration Protocol. In this procedure the network server or router takes note of a client’s MAC address and assigns an IP address to allow the client to communicate with other devices on the network.
DNS Server: A DNS (Domain Name System) server translates domain names (ie: www.vikingelectronics.com) into an IP address.
Ethernet: Ethernet is the most commonly used LAN technology. An Ethernet Local Area Network typically uses twisted pair wires to achieve transmission speeds up to 1Gbps.
Host: A computer or device connected to a network.
Host Name: A host name is a label assigned to a device connected to a computer network that is used to identify the device in various forms of network communication.
Hosts File: A file stored in a computer that lists host names and their corresponding IP addresses with the purpose of mapping addresses to hosts or vice versa.
Internet: A worldwide system of computer networks running on IP protocol which can be accessed by individual computers or networks.
IP: Internet Protocol is the set of communications conventions that govern the way computers communicate on networks and on the Internet.
IP Address: This is the address that uniquely identifies a host on a network.
LAN: Local Area Network. A LAN is a network connecting computers and other devices within an office or building.
Lease: The amount of time a DHCP server reserves an address it has assigned. If the address isn’t used by the host for a period of time, the lease can expire and the address can be assigned to another host.
MAC Address: MAC stands for Media Access Control. A MAC address, also called a hardware address or physical address, is a unique address assigned to a device at the factory. It resides in the device’s memory and is used by routers to send network traffic to the correct IP address. You can find the MAC address of your K-1775-IP phone printed on a white label on the top surface of the PoE LAN port.
Router: A device that forwards data from one network to another. In order to send information to the right location, routers look at IP Address, MAC Address and Subnet Mask.
RTP: Real-Time Transport Protocol is an Internet protocol standard that specifies a way for programs to manage the real-time transmission of multimedia data over either unicast or multicast network services.
Server: A computer or device that fulfills requests from a client. This could involve the server sending a particular file requested by the client.
Session Initiation Protocol (SIP): Is a signaling communications protocol, widely used for controlling multimedia communication sessions such as voice and video calls over Internet
Protocol (IP) networks. The protocol defines the messages that are sent between endpoints, which govern establishment, termination and other essential elements of a call.
Static IP Address: A static IP Address has been assigned manually and is permanent until it is manually removed. It is not subject to the Lease limitations of a Dynamic IP Address assigned by the DHCP Server. The default static IP Address is: 192.168.154.1
Subnet: A portion of a network that shares a common address component. On TCP/IP networks, subnets are defined as all devices whose IP addresses have the same prefix. For example, all devices with IP addresses that start with 100.100.100. would be part of the same subnet. Dividing a network into subnets is useful for both security and performance reasons. IP networks are divided using a subnet mask.
TCP/IP: Transmission Control Protocol/Internet Protocol is the suite of communications protocols used to connect hosts on the Internet. TCP/IP uses several protocols, the two main ones being TCP and IP. TCP/IP is built into the UNIX operating system and is used by the Internet, making it the de facto standard for transmitting data over networks.
TISP: Telephone Internet Service Provider
WAN: Wide Area Network. A WAN is a network comprising a large geographical area like a state or country. The largest WAN is the Internet.
Wireless Access Point (AP): A device that allows wireless devices to connect to a wired network using Wi-Fi, or related standards. The AP usually connects to a router (via a wired network) as a standalone device, but it can also be an integral component of the router itself.
Wireless Repeater (Wireless Range Extender): takes an existing signal from a wireless router or access point and rebroadcasts it to create a second network. When two or more hosts have to be connected with one another over the IEEE 802.11 protocol and the distance is too long for a direct connection to be established, a wireless repeater is used to bridge the gap.
3
Mounting Screws: (4) 6-32 X 3/4” Marine grade
316 stainless steel, flat head, T-10 Torx security screws and drive bit (included).
Speaker Screen: Speaker screen with 0.018" wide slots to prevent punctures from paperclips, etc.
Speaker: Mylar speaker with rubber gasket to maintain water-tight seal and eliminate water deterioration.
Microphone: Omni-directional microphone with protective water-resistant cloth.
Blue Call LED: Lights steady to help locate the button in low light, flashes during dialing, then lights steady when answered.
Faceplate Material: 14 gauge 316 stainless steel with #4 brushed finish.
Laser Etched Graphics: For long lasting easy to read graphics.
Features Overview
Front View of the
K-1275-IP Entry Phone
*
VIKING
©
1 2
3 4
5
6
*
7 8
9 0
#
Protective Camera Window: Impact resistant polycarbonate lens with scratch resistant coating and water-tight gasket.
Color Video Camera: Wide operating temperature range of -40°F to 140°F, NTSC composite video output with 420 lines of resolution, 80° wide viewing angle lens, tilt and swivel adjustments for aiming towards visitors.
Proximity Card Reader: 26-bit Wiegand,
125KHz, red LED turns off and transducer will beep during card read. Fully potted EWP. Read range 1.25" to 2.0". Impact resistant polycarbonate lens with water-tight gasket.
Keypad: Push to initiate call, push again to disconnect. Zinc Die cast with Satin Chrome
Finish, internally sealed per IP67.
Condensation Drain Hole
Optional: Connect to an additional
Long Range RFID Receiver with 26
Bit Wiegand Output (Viking Model
PRX-3 or LRR-4 See DOD# 228 or
226)
White
Proximity Card
Reader (26 Bit
Wiegand Input)
Green
+ Red
- Black
Optional
Long Range
RFID Receiver
Camera
Power
- Black
+ Red
12 VDC Power Output for
VE-LIGHT, etc.
(12VDC @ 50mA max)
- Black
+ Red
Request for Exit
(REX) Input
Relay 2 Output Contacts
(2A@30VDC/ 250VAC max)
Green
Green
N.C.
COM.
N.O.
Brown
Violet
White
Connect to Optional
Doorstrike, Mag Lock,
Gate Controller, etc.
120V AC
(not connected)
Doorstrike /
Magnetic Lock
(Power typically not required for gate controllers)
Relay 1
Output Contacts
(2A@30VDC/ 250VAC max)
N.C. (Gray)
COM. (Blue)
N.O. (Yellow)
3 Gel-Filled Butt
Connectors (included)
Rear (PCB) View of K-1275-IP
White
White
+ Red
- Black
- Black
+ Red
Black
Black
Speaker
LED
Microphone
Call Switch
PoE LAN Port 10/100,
PoE Class 2 (<6.5 Watts):
Connect to your LAN via
RJ45 plug and CAT5 or greater twisted pair wire.
MAC Address Label: The
MAC address is aunique
12 digit number used by routers to send network traffic to the correct IP address.
Yellow Network Status
LED: Lights steady to indicate power and data link. Blinks to indicate network activity.
Green Unit Status LED
Note: The gel-filled (water-tight) butt connectors are designed for insulation displacement on 19-26 gauge wire with a maximum insulation of 0.082 inches.
4
Installation and Mounting
A. Mounting
The K-1275-IP is designed to be installed in a sheltered location, and is not meant to be used outdoors. For outdoor applications use the K-1275-IP-EWP. The K-1275-IP can either be installed as a flush mount unit using the included rough in box, or as a surface mount unit using an optional VE-5x10 or VE-5x10-SS. The rough in box uses the inner set of four holes on the face plate while the VE-5x10 uses the outside set of holes. A set of dummy screws and nuts are provided to fill the unused mounting holes.
0.952"
Front View of the K-1275-IP
5.00"
4.50"
2.596"
0.425"
Side View of the K-1275-IP
4.5"
2.5"
Optional VE-5x10 Surface Mount
Box (not included), see DOD# 424
3.69"
5.22"
10.0"
9.5"
8.65"
9.12"
- OR -
10.14"
VIKING
©
14 Gauge Marine
Grade 316 Stainless
Steel Faceplate
(8) #6-32 x 3/4" Stainless
Steel, T-10 Torx Security
(included)
Zinc-Plated Steel
Rough-In Box
B. Changing the Directory
To install a directory, remove the four screws that mount the directory lens to the front of the K-1275-IP using the included Allen wrench. Insert a paper directory behind the lens and secure the two back onto the front panel being careful to align the names with the front panel graphics. For your convenience, the back of this document has pre-printed directory forms.
Note: To print directory forms for the K-1275-IP, go to www.vikingelectronics.com and enter “930” in the DOD field at the top of the page for a direct link to the PDF.
Paper Directory
Directory
Lens
5
Camera Wiring and Adjustments
IMPORTANT: Electronic devices are susceptible to lightning and power station electrical surges from the AC outlet.
It is recommended that a surge protector be installed to protect against such surges.
A. Using RG59 for Analog Video (Recommended)
Back View of the K-1275-IP
J6
Q171570
8
2W
J6
Model: xxxxxxxxx
S/N: XXXXXX
P/N: xxxxxxxxx DEV:
Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016
RoHS
3-Wire Gel-Filled Butt
Connectors included
(3M Scotchlok UR2)
Yellow (Video)
- Black (GND)
* Note: RG59 or RG6 with solid center conductor and 95% bare copper braid shield.
Center conductor stripped back 5/8"
* RG59 or RG6 Shielded
Video Cable, up to 1000 ft
Twisted foil and braided shield
Yellow/Red
OR
Black
** Female "F" to Wire or "BNC" to Wire
Converter Cable (not included)
"F"
Connector
"F" to Phono Plug
Adapter
(Radio
Shack part #278-252)
To unused input on TV,
VHF modulator, whole house video distribution equipment, IP video encoder (Axis M7001), etc.
** Note: For ease of installation, a Viking Female "F" to
Wire Converter Cable can be used (Part # 261217) or
"BNC" to wire converter cable (Part # U213510) can be used. Go to www.vikingelectronics.com and click on
"Spare Parts" to order.
B. Using CAT5E or CAT6 for Analog Video (see Caution below)
Back View of the K-1275-IP
J6
3-Wire Gel-Filled Butt
Connectors included
(3M Scotchlok UR2)
Video Out (+)
Video GND (-)
To unused input on TV, VHF modulator, whole house video distribution equipment, IP video encoder (Axis M7001), etc.
(-)
(+)
Phono (RCA) Plug,
F Connector, Etc.
W/G Green
J6
Video Out (+)
W/G
Video GND (-)
Green
CAT5E or
CAT6 Cable
(see Caution below)
Model: xxxxxxxxx
S/N: XXXXXX
P/N: xxxxxxxxx DEV:
Viking Electronics, Inc. (715)386-8861
1531 Industrial St., Hudson, WI 54016
RoHS
* Up to 150 ft
* Note: Up to 150 ft video cable run length can be achieved using CAT5E or CAT6 cable. Longer cable runs can be used if a passive or active video Balun transceiver is used on each end of the cable. Generally, passive transceivers can achieve up to 750 ft cable runs where active transceivers can achieve up to
3000 ft runs depending on cable type, etc. The type of video balun transceiver required is specific to your cable run length. For more information on video balun transceivers go to: www.northernvideo.com.
Caution: When routing CAT5E or CAT6 cable, maintain a minimum distance of 3 ft from any parallel high voltage wire (110 VAC) and a minimum of 2 ft from crossing any high voltage wire. For installations where RF noise is expected (commercial applications) or wire runs are near high voltage (110 VAC) wires, a shielded video cable such as RG6 is recommended.
C. Using a Video Encoder to Convert the Analog NTSC Video to IP
Axis manufactures video servers that encode analog video signal for transmission across IP network or the internet. The single channel model M7011 is shown. Supplied software allows you to access Axis units connected to the network (auto-discovery) and program them via a web page interface. The video can then be monitored from any location on the network.
For more information, go to www.axis.com
Axis Model
M7011 shown
D. Adjusting the Camera
The camera can be tilted and rotated to your desired position. A portable service (test) monitor can be used to determine the correct viewing angle during installation.
Important: To prevent the edge of the faceplate from being viewed in the video image, do not rotate the camera beyond 30 degrees or tilt beyond 20 degrees.
Vertical (Tilt)
Adjustment
+/- 20 degrees maximum
Horizontal (Rotation)
Adjustment
+/- 30 degrees maximum
1
3
5
7
9
*
0
#
6
8
2
4
VIKING
©
6
Using a Viking Model RC-4A for Secure Remote Relay Control
12V DC Adapter
(included)
Door / Gate Examples:
Door near Entry Phone 1
Relay 1 Output Contacts
(5A@30VDC / 250VAC max)
120V AC
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
COM.
N.O.
2 Gel-Filled Butt
Connectors (included)
Gate near Entry Phone 1
Relay 2 Output Contacts
(5A@30VDC / 250VAC max)
Connect to Gate Controller, etc.
Gate Controller
(Power typically not required for gate controllers)
COM.
N.O.
2 Gel-Filled Butt
Connectors (included)
VIKING
©
MODEL RC-4A
VIKING
ELECTRONICS
HUDSON, WI 54016
NETWORK ENABLED
RELAY CONTROLLER
1
RELAY 1
2 3 4
1 2 3 4 5 6
IN1 C IN2 IN3 C IN4
RELAY 2 RELAY 3 RELAY 4
STATUS
LED
5 6 7 8 9 10 11 12
LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
SPARE
1 2 3 4
NETWORK
LED 9
LED 1 LED 2
LED 5
LED 6
LED 3
LED 7
LED 8
LED 4 on
1 2 3 4
Switch
SIP VoIP PBX,
SIP Cloud based
Service Provider or
PC with SIP
Server Software
Sensor
Examples:
Door Sensor
Gate Sensor
Door Sensor
Door Sensor
IN1 C IN2 IN3 C IN4
1 2 3 4 5 6
PoE
Switch
Internet
K-1275-IP
Entry Phone 1
K-1275-IP
Entry Phone 2
K-1275-IP
Entry Phone 3
K-1275-IP
Entry Phone 4
Door near Entry Phone 2
Relay 3 Output Contacts
(5A@30VDC / 250VAC max)
120V AC
Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
Doorstrike /
Magnetic Lock
COM.
N.O.
2 Gel-Filled Butt
Connectors (included)
Door near Entry Phone 3
Relay 4 Output Contacts
(5A@30VDC /
250VAC max) Connect to Doorstrike,
Mag Lock, Gate Controller, etc.
120V AC
COM.
Doorstrike /
Magnetic Lock
N.O.
2 Gel-Filled Butt
Connectors (included)
The front panel of the K-1275-IP is mounted using security Torx screws to help prevent intruders from removing the panel and accessing the on board door strike/gate control relays. For applications requiring additional security, a Viking model
RC-4A remote relay controller can be used. The relay controller is mounted securely inside the building and connected to
the same LAN as the K-1275-IP. The on board door strike relays would not be used in this case as the K-1275-IP will send an encrypted message to the RC-4A to activate its relays which control the door strikes/gates.
Up to 4 K-1275-IP’s can communicate with one RC-4A allowing you to securely control four entrances.
When using an RC-4A for remote relay control the K-1275-IP’s relays should be set to “External” in the PC programming.
Note: If the K-1275-IP loses communications with the RC-4A, the LED on the front panel of the K-1275-IP will flash 3 times every 2 seconds indicating the communication error. If this error occurs, make sure the RC-4A is powered, has a network connection and has the correct IP address and security code of the K-1275-IP displaying errors.
7
Viking
K-1275-IP
Entry Phone
Typical Installation on SIP Based VoIP Phone System
100m (328 ft) maximum*
10/100 Mbps
Maximum
SIP VoIP PBX or
PC with
SIP Server
Software
Internet
Viking supplies
Optional
PoE Injector
(If VoIP PBX does not have PoE)
Customer’s
Responsibility
Optional
Switch / Hub
(Extends range of cable, keeps 1 Gbps network speed for other equipment on network)
VIKING
©
MODEL RC-4A
VIKING
ELECTRONICS
HUDSON, WI 54016
NETWORK ENABLED
RELAY CONTROLLER
1
RELAY 1
2 3
RELAY 2
4
1 2
IN1 C
5 6
3 4
RELAY 3
5
IN2 IN3 C
6
IN4
RELAY 4
7 8 9 10 11 12
STATUS
LED
LOGIC LEVEL
PROGRAMMING
RESTORE DEFAULTS
DEBOUNCE
1 2 3 4
NETWORK
LED 9
LED 2
LED 5 LED 6
LED 3
LED 7 LED 8
LED 4 LED 1 on
1 2 3 4
1 2 3 4 NETWORK
Optional Viking model
RC-4A Secure Remote
Relay Controller, see page 7 (DOD# 582)
* Note: A PoE extender can be used for an additional 100 meters per extender. For longer runs (up to 2 km / 1.2 miles) a ethernet to fiber media converter can be used.
PC Requirements
• IBM compatible personal computer with:
Windows 2000 (service pack 4 or higher)
Windows XP (service pack 2 or higher)
Windows Vista (SP2 or newer), 32 or 64 bit versions
Windows 7
Windows 8
Windows 10
• Adobe Acrobat Reader 8 or higher
• K-1275-IP hardware
• Available LAN with PoE (class 2, <6.5 watts)
• Ethernet cable ( CAT5 min.)
• 1 MB minimum free hard drive space for installation
• 16MB of free physical RAM
PC Programming
A DVD is included with each K-1275-IP VoIP Entry Phone. The DVD contains the application “Viking IP Programming” used to program the unit using a PC running Windows 2000, XP, Vista, Windows 7, Windows 8 or Windows 10 (see System
Requirements above). The PC must be connected to the same LAN as the K-1275-IP VoIP phone. Install the application on your PC by placing the DVD into your PC’s drive. Click “I Accept” on the bottom of the first screen, then select “Viking IP
Programming” and click the “Install” button. Follow the directions on the screen. To start the Viking IP Programming application, click on the Viking IP Programming icon on your desk top. The Main screen will appear, allowing the user to program any K-1275-IP phone connected to that LAN.
8
A. Connect/Disconnect
Open the “Viking IP Programming” software on the PC and the start screen shown below will appear. Any Viking IP phones that are connected to the network will appear on the list. Simply select the K-1275-IP on the list and click on the “Connect” button at the bottom or double click the selected phone. If the security code of the selected phone is still set to default (845464), the PC software will not require entering a security code to connect to the phone. K-1275-IP’s have a default name of “uCMK60_E_1600A_IP”, so if many phones are connected to the same network that all have the default name, MAC addresses must be used to identify each phone.
When finished programming, click on the “Disconnect” button at the bottom. Closing the program will also automatically disconnect the unit.
B. Manually Muting SIP/Network Failure Alarm Beeps
(3 beeps repeated every 30 seconds)
With the unit connected and powered (Green LED on and Yellow LED off or blinking) it will output 3 beeps every 30 seconds and turn the call LED on and off once per second to indicate a SIP registration failure, failure to receive an echo reply from pinged gateway or Ethernet connection failure. You can manually disable the beeps by pressing and holding the “
Q” button for 5 seconds (2 beeps will then be heard) or by clicking the “Mute Alarm Until Next Failure” button in the Viking VoIP programming software. The LED will continue to flash allowing you to trouble shoot the failure.
9
C. Configuring the K-1275-IP Network Settings
Step 1.
Step 2.
Open the “Viking IP Programming” software on a windows PC that is connected to the same LAN as the K-1275-IP phone to be programmed.
The window in the upper left corner of the menu will show you each K-1275-IP phone that is connected to that LAN. Select the unit with the same MAC address shown on the label located on the top of the Ethernet connector on the K-1275-IP phone.
Step 3.
Click the “Connect” button. If a pop up window appears, enter the unit’s security code (factory set to 845464) then click “OK”.
Step 4.
The program will then read and display the K-1275-IP phone’s IP and programming settings.
Step 5.
Click on the “IP Settings” tab and fill in the three required fields of SIP Server, Username and Password. The SIP provider or the phone system programmer provide the information to put in these fields. The SIP Server field can contain an IP address or a fully qualified domain name. Some examples are shown below. Our phones use port “5060” for traffic by default but another port can be specified by adding a “:” (colon) and the desired port number at the end of the SIP server IP address (for example “192.168.210.61:5070” to specify port “5070”). You can also assign a name for the K-1275-IP in the Unit Name field. When finished, click on the “Apply” button to send the
IP settings to the connected unit. See Examples 1 and 2 of the required fields below:
D. Manually Resetting the Security Code to Enter Programming
Step 1.
Power down the K-1275-IP phone by disconnecting the LAN Cable (RJ45 plug).
Step 2.
Press and hold the # key on keypad, then reconnect the LAN Cable (RJ45 plug).
Step 3.
Continue to hold # key until you hear 2 beeps, (approximately 6 seconds). Then release the button. The “Call” LED will remain off for the first 3 seconds, flash slowly for 3 seconds then fast flash (after 2 beeps), indicating when to release button.
Step 4.
The security code is now reset to 845464 (factory default).
Step 5.
You can now enter programming by following the steps in section A.
E. Manually Resetting All Network Parameters to Factory Default
Step 1.
Power down the K-1275-IP phone by disconnecting the LAN Cable (RJ45 plug).
Step 2.
Press and hold the # key on keypad, then reconnect the LAN Cable (RJ45 plug).
Step 3.
Continue to hold # key until you hear 2 beeps, (approximately 6 seconds). Continue to hold # key until you hear 4 more beeps, approximately 6 seconds later, then release the button. The “Call” LED will remain off for the first 3 seconds, flash slowly for 3 seconds
(2 beeps), fast flash for 6 seconds (4 beeps), then light steady indicating when to release button.
Step 4.
You can now enter programming by following the steps in section A.
10
Programming Features Index
DESCRIPTION
Connect/Disconnect
Phone Number Database
Event Log
Entry Code Database
Phone Name
Mute Alarm Until Next Failure
Phone Firmware
IP Firmware
Import/Export
Default Phone Settings
Diagnostics (used to check mic, speaker, relays and proximity card reader operation)
Security code (factory set to 845464)
Access Code (1-6 digits, blank = disabled, factory set to 123456)
Inbound Call Mode (Disabled, Auto Answer, Auto Answer-Secure, Silent Monitor, Silent Monitor-Secure)
Select Time Zone
Daylight Savings
Keyless/Card Logging
Relay 1 or 2 Mode (Door Strike, Outbound Call, In/Outbound Call, Doorbell, Alarm Mode, factory set to Door Strike)
Relay 1 or 2 Command (1 or 2 digits, factory set to
QQ and Q2) (Relay Mode must be set to Door Strike)
Relay 1 or 2 Time (0.5 - 99 sec, factory set to 5 sec)
Relay 1 or 2 Int/Ext (factory set to Internal)
Relay Activation Delay (Disabled or 0.5 - 99 sec, factory set to Disabled)
Relay Buzz (Activation Tone) Volume (1 digit 0-3, 0 = off, factory set to 3)
Relay Latch Commands (Enabled or Disabled, factory set to Enabled)
Speaker Volume (0-9, factory set to 2)
Microphone Volume (0-9, 0 = Auto, factory set to 5)
Talk/Listen Delay (VOX) (.1 to .9 sec, factory set to .5 sec)
Audio Call Progress (OFF, ON, factory set to ON)
Audio Detect Level (1-9, 1 = min, 9 = max, factory set to 5, power cycle unit after setting)
Call Length Time Out (disabled or 1 to 9 min, factory set to 3 min)
Dial Next Number on RNA (Ring No Answer) (disabled, 1 - 9 = number of rings, factory set to 7)
Dial Next Number on Busy (disabled or enabled, factory set to enabled)
REX Input
16
16
16
16
16
16
16
15
15
15
15
15
17
17
17
17
17
18
18
18
18
17
17
17
Page
9
12
13
14
14
14
14
15
15
17
18
19
20
14
15
16
9
10
11
12
13
21
22
23
24
25
29
30
31
32
26
27
28
Section
A
1
2
3
4
7
8
5
6
11
Programming Features
1. Phone Number Database
Clicking on the “Phone Number Database” button will open a screen allowing you to program all the Tenants Name’s,
Speed Dial Numbers, and Primary and Roll Over phone numbers. Tenant names are stored locally on the PC and are not uploaded.
The Speed Dial Number is the single digit number visitors enter on the K-1275-IP’s keypad for the unit to call the tenant.
3 seconds after the number is entered, the unit will then dial the Primary Phone Number associated with that Speed
Dial Number. If there is no answer or a busy signal is detected, the K-1275-IP will then dial the Roll Over Phone Number.
12
2. Event Log
The Event Log button is used to open the Event Log screen. The Event Log screen shows you the time and date of each event, the event type, relay action (which door/gate was opened or closed), entry code index and phone number index with tenant name. The Event Log can store up to 4,095 events. Events are stored in a first in first out format.
When the memory is full, new events will over write the oldest events. The Event log can be saved in one of two file formats: Tab Delimited Text or Comma Separated Variable.
13
3. Entry Code Database
Clicking on the “Entry Code Database” button will open the Entry Code Database screen.
The Entry Code Database will then download, this can take over a minute. The Entry Code Database will allow you to program the Relay Function, Relay 1 or 2, once only (one time use only), Entry Type (Card, Keyless or both), Keyless
Code, Proximity Card #, Facility Code, Day of week, Time of Day and Tenant Name. Tenant names are stored locally on the PC and are not uploaded. When “Card + Keyless” is selected, a valid card must be presented and the keyless code entered within 15 seconds.
4. Phone Name
Up to a 31 character phone name can be assigned to the K-1275-IP being programmed. Often times the building name and entrance location near the unit are used for the name.
5. Mute Current / Next Alarm
A network failure alarm will be indicated by providing 3 beeps every 30 seconds in the handset of the K-1275-IP. A network failure indicates the unit is not registered to the SIP server or there is a communication failure with the gateway.
The three beeps can be muted by clicking on “Mute Current / Next Alarm”.
6. Phone Firmware
If new K-1275-IP firmware is available, after opening the programming software a pop up window will ask if you would like to update firmware. Another way to update is accomplished by clicking the phone firmware “Update” button. You can then browse to the folder that contains the HEX file for updating the unit’s firmware. This method is typically only used when Viking Technical Support has sent you updated firmware.
7. IP Firmware
If new K-1275-IP firmware is available, after opening the programming software a pop up window will ask if you would like to update firmware. Another way to update is accomplished by clicking the IP firmware “Update” button. You can then browse to the folder that contains the PIP file for updating the unit’s IP firmware. This method is typically only used when Viking Technical Support has sent you updated IP firmware
14
8. Import/Export
The Import/Export feature is useful for backing up all the K-1275-IP’s programming or for importing programming when installing multiple units with a majority of the same programming.
9. Default Phone Settings
Clicking on the “Default Phone Settings” button in programming will reset all of the Programming Features back to their factory default settings. Note: This command will not change or reset your IP settings.
10. Diagnostics
The Diagnostics section in the Viking IP Programming can be used to test the functionality of the two relays, read current relay status or to display information on the last card or fob detected by the card reader.
11. Security Code
The security code allows the user/installer to program the K-1275-IP phone. The factory set security code is 845464.
It is recommended that the factory set security code be changed.
Note: The security code must be 6 digits and cannot include a
Q or a #.
12. Access Code
The Access Code is used for remotely operating the relays (Doorstrike, Mag-Lock, etc) by calling into the unit. This code provides basic security and only allows operation of the relays and not the ability to change any of the programming parameters. Once entered, any of the “Remote Access Operation Commands” can be used. The code can be 1 to 6 digits in length and cannot contain a “
Q” or “#”. Simply call the K-1275-IP phone (set to auto-answer/auto-answer secure), the unit will automatically answer the line and output one beep. You then enter the programmed 1 to 6 digit access code, 2 beeps should be heard. You can now enter any “Remote Access Operation Commands” (see page 19).
13. Inbound Call Mode
The Inbound Call Mode determines how the K-1275-IP handles incoming calls. One option is to generate a loud ring sound through the handset receiver, allowing someone to lift the handset to answer the inbound call. The K-1275-IP can also auto answer the call, to allow remote control of the doorstrike relays and the ability to listen to transmit audio from the handset of the phone. The last option is the silent monitor mode, which allows callers to listen to the transmit audio from the handset of the phone at a much higher volume than normal. The “secure” options for auto answer and silent monitor require the callers to dial the access code in order to remain connected and listen to the audio from the handset.
Disabled – Inbound calls are not allowed.
Auto Answer – Inbound calls are auto answered on the first ring.
Auto Answer Secure – Inbound calls are auto answered and the caller must dial the access code in order to listen or talk on the unit.
Silent Monitor – Inbound calls are auto answered and the caller hears transmit audio from the microphone at a much higher volume level.
Silent Monitor Secure – Inbound calls are auto answered and the caller must dial the access code in order to listen to transmit audio from the microphone (volume level is still at a much higher volume level).
15
14. Select Time Zone
When using date and time logged events or setting the access date and times of keyless codes or proximity cards in the Entry Code
Database, you must program the unit to your time zone. Example: You are installing the K-1275-IP in the Central standard time zone:
Select (UTC - 06:00) CST, which is 6 hours behind Coordinated Universal Time (UTC).
15. Daylight Savings
The Daylight Saving Time programming can be enabled or disabled and can be programmed to start on any Sunday in March and stopped on any Sunday in November. Currently, daylight saving time starts on the second Sunday in March and ends on the first
Sunday in November, with the time changes taking place at 2:00AM local time.
16. Keyless/Card Logging
Keyless Entry Code and Proximity Card logging can be set to Log Errors. With Log Errors selected (default selection), the K-1275-
IP will not only log all valid Keyless Entry Code and Proximity Card entries, but also log any errors, incorrect codes, or non-valid card reads.
Keyless Entry Code and Proximity Card logging can also be set to Live Logging. With Live logging selected and the K-1275-IP programming software open and connected to a unit, each Keyless Entry Code entered or Proximity Card read will immediately open the Event Log screen and display the latest entry.
17. Relay Mode
Doorstrike Mode: When programmed for Doorstrike Mode the relay is intended for door strike, maglock or gate control. The relay can also be touch tone activated by dialing a “#” plus a valid keyless entry code or by scanning a valid proximity card that has been assigned to that relay.
Outbound Call Mode: When programmed for Outbound Call Mode the relay will activate continuously for the duration of any outbound call from the Entry phone.
Inbound/Outbound Call Mode: When programmed for Inbound/Outbound Call Mode the relay will activate continuously for the duration of any inbound or outbound call to or from the Entry phone. This mode is useful for turning on IR flood lights, for VoIP phones with cameras, etc.
Doorbell Mode: When programmed for Doorbell Mode the relay will momentarily activate the relay for the preprogrammed relay activation time on any outbound call from the Entry phone. This mode is useful for activating a door chime, etc. When activating door chimes, a 0.5 - 1 second relay activation time is recommended. Note: Activation time must be set before Doorbell Mode is selected.
Alarm Mode: When programmed in Alarm Mode the relay will activate continuously while the Entry phone is powered and registered to the SIP server. In the event the unit loses power and/or SIP registration the relay will turn off, which can be used to signal an alarm device.
18. Relay 1 or 2 (Activation) Command
The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being called must enter on their phone in order to momentarily activate relay 1 or 2 to control a doorstrike, mag-lock, gate controller, or other device.
The code can contain the characters 0 - 9, # or
Q. The code cannot match a relay latching or toggle command (11, 10, 1#, 21, 20, or 2#). The code must be entered while the remote phone is communicating with the Entry phone. The Entry phone determines which direction the touch tone is coming from and only responds to touch tones from the called phone. The factory setting is
QQ for relay
1 and
Q2 for relay 2.
19. Relay 1 or 2 Activation Time
The value stored in the Relay 1 or 2 Activation Time is the amount of time relay 1 or 2 will be energized after a correct momentary touch tone command is entered, “#” plus a valid keyless entry code or a proximity card was scanned that is programmed to momentarily activate the relay. This number can range from 0.5 to 99 seconds. The factory setting is 5 seconds.
20. Relay 1 or 2 Internal / External
With relay 1 and/or 2 set to “Internal” the K-1275-IP will activate its on board relays for door strike / gate control. Relay 1 and/or 2 should be set to “External” for higher security installations when using a Viking remote model RC-4A relay controller to activate the door strike / gate controller (see page 6).
16
21. Relay Activation Delay
A relay activation delay of 0.5 to 99 seconds or disabled can be programmed in the K-1275-IP. A relay activation delay is useful in two door vestibule entrance applications. This allows you to program a delay time from when relay 1 (outside door) is activated to when relay 2 (inside door) is activated. The programmed delay time should be set to the average time it takes a person to walk from the outside door to the inside door. If set to “Disabled” only relay 2 will activate.
When a request for exit (REX) is activated, relay 2 will activate first, then after the programmed delay relay 1 will activate.
22. Relay Buzz (Activation Tone) Volume
The relay activation tone is a buzzing sound that is heard at the Entry phone when the door strike relay is activated.
After the called party enters the correct relay activation command, the called party will hear 2 short confirmation beeps and the entry phone will output a buzzing sound (relay activation tone) when the door strike relay is activated. The tone (buzz) length will match the relay activation time up to a maximum of 5 seconds. The tone (buzz) can be programmed to three different volume settings 1 = Low, 2 = Medium, 3 = High or it can be disabled.
The volume will also vary with the speaker volume setting.
23. Relay Latch Commands
When programmed to “Enable” (factory default) the Remote Access Operation Commands to Un-Latch, Latch or Toggle the relay are enabled.
When programmed to “Disable” the Remote Access Operation Commands to Un-Latch, Latch or Toggle the relay are disabled.
Disabling the Latch commands can be useful in applications where you want to eliminate the possibility of inadvertently entering a latch command leaving a gate open/closed, etc.
24. Speaker Volume
The speaker volume can be set from 0 to 9 (0 = lowest volume setting, 9 = the highest, factory set to 2).
25. Microphone Volume / Automatic Noise Cancelling Mode
The microphone volume can be set from 1 to 9 (1 = lowest volume setting, 9 = the highest, factory set to 5). Alternatively the microphone can be placed in the “Auto” Automatic Noise Cancelling mode. With the mic in the Auto mode, when background noise increases, the mic gain will automatically decrease. When background noise decreases the mic gain will automatically increase. The Auto mode is useful in applications where the background noise level can change drastically such as a gas car running vs a diesel truck.
26. Talk / Listen Delay (VOX)
This feature selects switching time between talk and listen modes (VOX switching time). The Talk/Listen Delay can be programmed from .1 to .9 seconds.
Note: The factory default is .5 seconds.
27. Audio Call Progress (In-Band Audio Call Progress Detection)
The In-Band Audio Call Progress Detection can be set to enabled or disabled. In-Band Audio Call Progress detection should be enabled in applications where you are making an outbound call through your VoIP phone system and are relying on In-Band analog audio for ringback or busy detection. The factory default is: Enabled.
28. Audio Detect Level (In-Band Audio Detection Level / Sensitivity)
The In-Band Audio Detection level (Sensitivity) can be set from 1 to 9 (1 = minimum setting, 9 = the highest, factory set to 5). Increasing or decreasing the sensitivity may be required in applications where you are making an outbound call through your VoIP phone system and are relying on In-Band analog audio detection.
17
29. Call Length Time Out
This feature selects the maximum length of time that calls can be connected. Programmable in increments of 1 minute up to a maximum of 9 minutes or disabled. With the call length disabled, the K-1275-IP phone must rely on a call ended signal, busy signal, silence, Ring No Answer limit, or return to dial tone to hang-up.
Note: The factory default is 3 minutes.
30. Dial Next Number on RNA (Ring No Answer)
If enabled and a ring-no-answer is detected, the K-1275-IP phone will dial the “Roll Over” speed dial number.
Note: Factory set to redial if not answered after 7 rings.
31. Dial Next Number on Busy
If enabled and a busy is detected, the K-1275-IP phone will dial the “Roll Over” speed dial number. Notes: This feature
is enabled in the factory default setting. If the busy signal is interrupted with a promotional message, contact your central office to have it removed.
32. REX Input
The K-1275-IP has one Request for Exit (REX) trigger input. The REX switch must have a momentary, normally open contact.
When the K-1275-IP detects a contact closure on the REX trigger input it performs one of the following actions, based on the Relay
Mode settings for each relay (see section 22):
Relay 1 "Door Strike", relay 2 other: Relay 1 will be activated for the programmed Relay 1 Activation Time.
Relay 1 other, relay 2 "Door Strike": Relay 2 will be activated for the programmed Relay 2 Activation Time.
Relay 1 "Door Strike", relay 2 "Door Strike": If the Relay Activation Delay is disabled, Relay 2 will be activated for the programmed
Relay 2 Activation Time. If Relay Activation Delay is not disabled, Relay 2 will be activated for the programmed Relay 2 Activation
Time, then after the Relay Activation Delay time has passed, Relay 1 will be activated for the programmed Relay 1 Activation Time.
This is useful in two door vestibule applications where Relay 1 is used to unlock the outside door, and Relay 2 is used to unlock the inside door.
Operation
A. Keypad
When a Keypad button is pressed, the K-1275-IP immediately dials the pre-programmed telephone number stored in the corresponding Phone Number Database Index location (1-#). The Call Status LED momentarily flashes during dialing. In the event the line is busy or there is a ring-no-answer, the unit can be programmed to call a second roll over number.
When the call is answered, relay activation commands can be entered or the # key can be used to force the phone to hang-up.
After communication is established, enter the 1 or 2 digit relay activation command (factory set to “
QQ” for Relay 1 and
”
Q2” for Relay 2
) to momentarily activate the entry phone (door strike) relay. Two beeps will be heard confirming that the relay has been activated. If you require the relay to remain on continuously (ie: a truck delivery), enter Touch Tones “11” or “21” to continuously activate relay 1 or relay 2 respectively. A double beep will indicate that the relay is latched on.
When the visitor calls in again (ie: they are finished unloading the truck), enter Touch Tones “10” or “20” to deactivate relay 1 or relay 2 respectively. A single beep will indicate the relay is latched off. The relays can be toggled by entering
“1#” and “2#” for relays 1 and 2.
18
B. Remote Access Operation Commands
The following commands can be entered after answering an inbound call from the entry phone. The commands can also be entered on an outbound call to the entry phone. After the entry phone auto answers the call, one or two beeps will be heard. If the access code has been disabled (two beeps heard), you can now enter the Remote Access Operation Commands below. If an Access code has been programmed (one beep heard), enter the Access code digits. With the correct code entered, two beeps will be heard and you can now enter the Remote Access Operation Commands below. The relay must be set to “Door Strike” Mode to be controlled by these commands.
Feature
Momentarily
Activate Relay 1
Touch Tone
Command
QQ or
___ ___
Description
Momentarily activate relay 1 (1 or 2 digits, factory set to
QQ).
Latch Relay 1 11
Latch* (continuously activate) relay 1.
Un-Latch Relay 1
Toggle Relay 1
Momentarily
Activate Relay 2
Latch Relay 2
10
1#
Q2 or
___ ___
21
Un-latch* (deactivate) relay 1.
Toggle relay 1 from last position.
Momentarily activate relay 2 (1 or 2 digits, factory set to
Q2).
Latch* (continuously activate) relay 2.
Un-Latch Relay 2
Toggle Relay 2
Disconnect
20
2#
#
Un-latch* (deactivate) relay 2.
Toggle relay 2 from last position.
Disconnects or forces the phone to hang up.
* Note: Relay latch commands must be enabled in programming.
C. Keyless Entry Codes and One Time Use Keyless Entry Codes
Keyless entry codes may be used by the tenants to provide keyless entry. The K-1275-IP can be programmed with a combination of up to 1000* keyless entry codes or one time use keyless entry codes. The keyless entry codes can be programmed to be from 1 to 6 digits in length. Each keyless entry code can be programmed to activate relay 1 and/or 2 in four different relay modes: Momentary, Latch, Un-
Latch and Toggle. To use a keyless entry code the tenant simply dials “#” followed by the entry code on the K-1275-IP’s keypad. After the one time use keyless entry code has been used, it is instantly cleared from the unit’s memory. This is ideal for issuing keyless entry codes to service personnel, etc.
2. If keyless entry codes are used, leave the “#” position blank in the Phone Number Database.
D. Proximity Cards / Fobs
Proximity cards or Fobs can also be used by the tenants to provide keyless entry. The K-1275-IP can be programmed with up to 1000* proximity card numbers. Each proximity card number can be programmed to activate relay 1 and/or 2 in four different relay modes:
Momentary, Latch, Un-Latch and Toggle. To use a proximity card the tenant simply presents a preprogrammed proximity card within **6 inches of the proximity card reader attached to the K-1275-IP. A short beep will be heard from the card reader indicating a card scan. If the card matches a valid preprogrammed card number a short buzz sound
(if enabled) will be heard indicating the relay has been activated and the visitor can now open the door or gate.
* Note: 1000 is the total number of Keyless Entry Codes and/or Proximity Card numbers that can be programmed in the Entry Code Database.
** Note: Read range is dependent on the card reader type.
Troubleshooting
If the unit cannot register with the programmed SIP server, the LED will blink on and off every second, and three error beeps will be heard every 30 seconds until communication is restored. This alerts a potential user of a problem with the device that will prevent an emergency phone call from being made.
19
Related Products
Surface or Pedestal Mount Viking Products
While Maintaining Weather and Vandal Resistance
The VE-3x5, VE-5x5, VE-6x7 and VE-5x10 add vandal and weather resistance, as well as versatility to many Viking products.
The VE-Series backboxes are available in black fine texture powder painted steel or marine grade 316 stainless steel. The weather resistant boxes are designed to be surface mounted to a wall, post, single gang box, or a VE-GNP gooseneck pedestal.
Note: The VE-3x5 is not compatible with the VE-GNP pedestals and is not available in stainless steel.
VE-5x5 VE-5x5-SS VE-5x5-RD VE-5x5-PNL VE-5x5-PNL-SS
VE-6x7 VE-6x7-SS VE-6x7-PNL VE-6x7-PNL-SS
VE-GNP-2
VE-GNP-IP
The VE-GNP gooseneck pedestals are designed to be used with the
VE-5x5, VE-6x7 and VE-5x10
backboxes and are ideal for drive up communications. Note: The
VE-3x5 is not compatible with the
VE-GNP pedestals.
VE-3x5
VE-5x10 VE-5x10-SS VE-5x10-PNL VE-5x10-PNL-SS
VE-GNP-SS
VE-GNP
The VE-PNL’s are VE-Series backboxes with a blank aluminum panel. The user can customize the clear-coated aluminum panel to mount an PRX-1 card reader, PRX-
2 keypad or switch. The kits come complete with box, gasket, panel and screws.
Model numbers that end with “SS” are stainless steel version. Note: The use of
magnets to mount the VE-Series enclosure to a metal surface can affect the operation of the enclosed product.
Caution: Handsfree phones are not suitable for noisy applications (see “Important” on page 2).
For more information on Viking Surface Mount Boxes and Pedestals, see DOD# 424.
Add Panel Lighting to Your Viking VoIP Entry Phone
The VE-LIGHT kit adds bright LED illumination to any VoIP entry phone that is housed in a Viking VE-5x5, VE-6x7 or VE-5x10 enclosure.
The stainless steel bracket is easily mounted using existing holes and hardware.
Two bright white LEDs are used as the light source, so there are no filaments to break or bulbs to burn out.
12 VDC power adapter included. Any power source between 12 and 24 volts, AC or
DC can be used to supply the VE-LIGHT with power.
For more information, See DOD# 428.
VE-LIGHT shown right with Viking
E-30 and VE-5x5 (not included)
20
Related Products
Control Relay Contacts Across a Local Area Network
The RC-4A Network Enabled Relay Controller provides networked control of four relays via an easyto-use web interface. The same interface can be used to check the status of four contact closure inputs. Relays can be toggled on or off, or user-programmed timed closures can be activated.
The RC-4A can be configured to work as a remote relay for Viking VoIP series entry phones, controlling door strikes and gates when a remote relay is required for security reasons. It can also be programmed to send an email or text message in response to a change in one or more of the sensor inputs. Two RC-4A’s can be set up so that activity on a sensor input of one unit will automatically send a message across the network to activate one of the relays on the other unit.
Two levels of user access permit selected users to have full operational and programming rights while others have operational control but not programming capability.
For more info, see DOD# 585
Long Range 4 Channel Transmitters and
Receivers
Viking’s model LTR-4 Long Range Wireless 4
Channel Radio Transmitters and LRR-4 Long
Range 4 Channel Receivers with integrated receive antenna comprise Vikings high frequency, long-range (RFID) identification solution. Intended for security access control applications, the LRT-4’s wireless communication is based upon a secure, digital, anti-playback
LRR-4 LRT-4
routine. The LRT-4 Transmitters have four buttons, each corresponding to its own Wiegand output on the LRR-4 Receiver. Each Transmitter includes an integrated red
LED, used to indicate both positive button press and battery strength. They are also equipped standard with a 125KHz HID** compatible potted proximity module allowing the Transmitter to also be used as a close range access credential.
The transmitters and receivers operate at 433-MHz allowing a transmission range of up to 500 ft (line of sight). The LRR-4 receiver has an adjustable read range, optional external antenna connector, terminal block with 4 channel Wiegand data output and a transducer and LED to confirm transmitter button press. The LRR-4 has a conformal coated circuit board mounted in a NEMA 4, 4x rated box for use in outdoor applications.
See
DOD# 226 for more information.
125KHz Proximity Cards
The PRX-C and PRX-C-ISO are non-contact security cards that can be presented to the front of a K-1770/75-IP proximity card reader to allow entrance into a secured area. The PRX-C is a clam shell card made made from 0.070” thick plastic to resist bending and folding. A slot is provided at one end to allow a lanyard to be added for creating a “dog tag” style neck strap. The PRX-C-ISO is a thin 0.032” thick flexible “ISO” style proximity card. Much like a credit card, the PRX-C-ISO is perfect for storing in your wallet.
The PRX-FOB is a proximity key ring fob with brass eyelet designed to attach to a key chain or necklace. The PRX-FOB’s compact size is only 1.5” x 1.2” x
0.15” making it one of the smallest available.
The cards and fobs are custom pre-programmed.
For more information see DOD# 198.
21
Medium Range 125KHz Proximity
Card Reader
The model PRX-3 is a high performance medium range
125KHz proximity card reader.
The PRX-3’s compact size yet long read range of up to 16 inches* make it ideal for parking control, gate access, turnstiles,
PRX-3
etc. It is designed to be mounted directly to a wall, post, single gang electrical box or use an optional mounting kit for attaching it to a gooseneck pedestal. Mounting is simplified with horizontal and vertical mounting slots, which allow the reader to be conveniently adjusted and leveled. To increase vandal resistance the chassis is a single piece design with the mounting screws concealed behind a UV stable label.
The proximity card reader transmits data in 26-Bit Wiegand format, making it compatible with any of the Wiegand equipped Viking entry controllers. The PRX-3 is equipped with Enhanced Weather
Protection (EWP) for outdoor installations where the unit is exposed to precipitation or condensation. With its sealed connections and fully potted electronics the PRX-3 is designed to meet an IP66 Ingress Protection Rating. For more information
see DOD# 228.
Gooseneck Pedestal Mounting Kit
PRX-3 shown with
VE-GNP pedestal,
PRX-3-MK-VEGNP
mounting kit and
K-1275-IP with
VE-6x7
The model PRX-3-MK-VEGNP is a mounting kit for attaching the PRX-3 proximity card reader and a VE-5x5, VE-6x7 or VE-5x10 (surface mount entry phone box) to a VE-GNP gooseneck pedestal. It includes the required mounting hardware, has a mounting plate made from durable 3/8 inch thick black UV stable textured ABS plastic and a gasket for sealing the back side of the VE surface mount box.
For more info see DOD# 229
Warranty
IF YOU HAVE A PROBLEM WITH A VIKING PRODUCT, CONTACT: VIKING TECHNICAL SUPPORT AT (715) 386-8666
Our Technical Support Department is available for assistance Monday through Friday 8:00am to 5:00pm central time. So that we can give you better service, before you call please:
1. Know the model number, the serial number and what software version you have (see serial label).
2. Have your Product Manual in front of you.
3. It is best if you are on site.
RETURNING PRODUCT FOR REPAIR
The following procedure is for equipment that needs repair:
1. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (RA) number. The customer MUST have a complete description of the problem, with all pertinent information regarding the defect, such as options set, conditions, symptoms, methods to duplicate problem, frequency of failure, etc.
2. Packing: Return equipment in original box or in proper packing so that damage will not occur while in transit. Static sensitive equipment such as a circuit board should be in an anti-static bag, sandwiched between foam and individually boxed. All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment. Include ALL parts of the equipment. C.O.D. or freight collect shipments cannot be accepted. Ship cartons prepaid to: Viking Electronics, 1531 Industrial Street, Hudson, WI 54016
3. Return shipping address: Be sure to include your return shipping address inside the box. We cannot ship to a PO Box.
4. RA number on carton: In large printing, write the R.A. number on the outside of each carton being returned.
RETURNING PRODUCT FOR EXCHANGE
The following procedure is for equipment that has failed out-of-box (within 10 days of purchase):
1. Customer must contact Viking’s Technical Support at 715-386-8666 to determine possible causes for the problem. The customer MUST be able to step through recommended tests for diagnosis.
2. If the Technical Support Product Specialist determines that the equipment is defective based on the customer's input and troubleshooting, a Return
Authorization (R.A.) number will be issued. This number is valid for fourteen (14) calendar days from the date of issue.
3. After obtaining the R.A. number, return the approved equipment to your distributor, referencing the R.A. number. Your distributor will then replace the
Viking product using the same R.A. number.
4. The distributor will NOT exchange this product without first obtaining the R.A. number from you. If you haven't followed the steps listed in
1, 2 and 3, be aware that you will have to pay a restocking charge.
TWO YEAR LIMITED WARRANTY
Viking warrants its products to be free from defects in the workmanship or materials, under normal use and service, for a period of two years from the date of purchase from any authorized Viking distributor. If at any time during the warranty period, the product is deemed defective or malfunctions, return the product to Viking Electronics,
Inc., 1531 Industrial Street, Hudson, WI., 54016. Customer must contact Viking's Technical Support Department at 715-386-8666 to obtain a Return Authorization (R.A.) number.
This warranty does not cover any damage to the product due to lightning, over voltage, under voltage, accident, misuse, abuse, negligence or any damage caused by use of the product by the purchaser or others. This warranty does not cover non-EWP products that have been exposed to wet or corrosive environments. This warranty does not cover stainless steel surfaces that have not been properly maintained.
NO OTHER WARRANTIES. VIKING MAKES NO WARRANTIES RELATING TO ITS PRODUCTS OTHER THAN AS DESCRIBED ABOVE AND DISCLAIMS ANY
EXPRESS OR IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
EXCLUSION OF CONSEQUENTIAL DAMAGES. VIKING SHALL NOT, UNDER ANY CIRCUMSTANCES, BE LIABLE TO PURCHASER, OR ANY OTHER PARTY,
FOR CONSEQUENTIAL, INCIDENTAL, SPECIAL OR EXEMPLARY DAMAGES ARISING OUT OF OR RELATED TO THE SALE OR USE OF THE PRODUCT SOLD
HEREUNDER.
EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY. WHETHER IN AN ACTION BASED ON CONTRACT, TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY)
OR ANY OTHER LEGAL THEORY, ANY LIABILITY OF VIKING SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE PRODUCT, OR AT VIKING'S OPTION,
REFUND OF THE PURCHASE PRICE AS THE EXCLUSIVE REMEDY AND ANY LIABILITY OF VIKING SHALL BE SO LIMITED.
IT IS EXPRESSLY UNDERSTOOD AND AGREED THAT EACH AND EVERY PROVISION OF THIS AGREEMENT WHICH PROVIDES FOR DISCLAIMER OF
WARRANTIES, EXCLUSION OF CONSEQUENTIAL DAMAGES, AND EXCLUSIVE REMEDY AND LIMITATION OF LIABILITY, ARE SEVERABLE FROM ANY OTHER
PROVISION AND EACH PROVISION IS A SEPARABLE AND INDEPENDENT ELEMENT OF RISK ALLOCATION AND IS INTENDED TO BE ENFORCED AS SUCH.
If trouble is experienced with the K-1275-IP phone, for repair or warranty information, please contact:
Viking Electronics, Inc., 1531 Industrial Street, Hudson, WI 54016 (715) 386-8666
WHEN PROGRAMMING EMERGENCY NUMBERS AND (OR) MAKING TEST CALLS TO EMERGENCY NUMBERS:
Remain on the line and briefly explain to the dispatcher the reason for the call. Perform such tests in off-peak hours, such as early morning or late evenings.
PART 15 LIMITATIONS
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
Product Support: (715) 386-8666
Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.
DOD# 274 Printed in the U.S.A.
22
ZF303880 REV 2

Public link updated
The public link to your chat has been updated.
Advertisement