10 Katalog_NEU.indd - Multiplan Electronics
Index
Table of contents
Table
of contents
Category
Index
Page
Business Company
Chronology / Array of products
2-3
UPS classification
UPS classification / Technology
4-5
AC line-interactive UPS 400-3200VA
ME series
6-7
MI-RM series
8-9
MTD series
MTD-RM series
AC online double-conversion UPS
700-3000VA
AC large UPS 6-300kVA
MT series
14-15
MT-RM series
16-17
MKD series
18-19
MKD-RM series
20-21
MH/MHD series
22-23
MH-RM/MHD-RM series
24-25
MH 6000
26-27
MH 6000 RM
28-29
MHD 10-20kVA
30-31
MHD RM 10kVA
Quasar II
AC large modular UPS 4-120kVA
NEU / NEW 10-11
NEU / NEW 12-13
NEU / NEW 32-33
NEU / NEW 34-35
Quasar 60-120kVA
36-37
Pegasus 10-40kVA
38-39
Pegasus 60-160kVA
40-41
Pegasus 200-300kVA
42-43
MHD Modular
44-47
MHD Modular P3
NEU / NEW 48-49
50-51
UPS-Management
Software
SNMP / web adapters
52-53
Accessories
External bypass
54
Batteries
AC/DC power supplies, chargers, inverters / rectifiers
Battery-cabinet
55
BT series batteries
56-57
BTL series batteries
58-59
Front terminal batteries
60
Terminal types
61
BACS battery management
62-69
DC UPS, DIN-rail
70-71
Modular DC power supply systems 48-60V
72-87
Modular DC power supply systems 108-220V
88-91
EFFEKTA Charger
Mascot power supplies, chargers, converters
Solar inverter
Solar-LogTM
Mobile inverters WRI
Mobile inverters WRS
NEU / NEW 92-93
94-95
NEU / NEW 96-97
NEU / NEW 98-99
NEU / NEW 100-101
102-103
Special appliances AC
Special appliances
104-105
Service
Service
106-107
References
AGBs
References
108-109
Terms & Conditions
110
1
Power Supplies
Business Company Company
Business
Chronology & development:
- Foundations:
HJ Elektronik in 1984
EFFEKTA® Regeltechnik GmbH in 1990
EFFEKTA® (Taiwan) in1991
EFFEKTA® (Hungary) in 1998
Rottweil sales department in 1999
Amalgamation of business of Tettnang and Rottweil
in Rheinwaldstraße 34, Rottweil in 2007
.
.
.
.
.
.
- Management-buy-out in 2000 with new directors:
P. Androt, G. Kremer and R. Schmeh
- Today:
the company employs 62 staff.
2
EFFEKTA has been successfully operating on the UPS
market for over 18 years. Over the years, our company
has come to epitomise reliability and quality and we are
now one of the leading UPS manufacturers in Germany.
This success has been made possible by consistent
ongoing, development and the use of innovative
technology.
®
The fact that EFFEKTA UPSs are used every day in
renowned companies such as Berliner Verkehrsbetriebe
(Berlin Municipal Transport Company), Daimler
Chrysler, SIEMENS, Deutsche Telekom, BASF, BayerLeverkusen, Deutsches Institut für Luft- und Raumfahrt
(German Aerospace Centre) and many more is
testament to their high quality (s. p. 110/111).
®
Business Company
UPS-Systems
Pegasus 10-40 kVA
Pegasus 60-160 kVA
Pegasus 200-300 kVA
(from left to right)
Most UPSs are employed to safeguard data processing
functions in case of power disturbances. EFFEKTA
UPSs are not only suited to use with computers, but also
with all sensitive, power-dependent units.
®
The EFFEKTA range provides a solution for every
kind of application we have got a solution. We are also
experienced in custom designs and small production
runs.
®
We now have expanded our array of products to
include rectifiers, inverters and power supplies for every
requirement and also DC UPSs for telecommunications
or wireless network operators.
Our array of products:
. Line-interactive UPSs up to 3.2kVA
. Online double-conversion UPSs up to 800kVA
. Single- and three-phase standalone units
. 19” versions and more special enclosures
. Redundant systems, AC and DC up to 800kVA (KW)
. UPS management solutions
. Inverters / rectifiers
. DC UPS systems
. Power supplies
. Batteries 2/6/12V, 0.8 ... 2000Ah
. ”BACS” battery control/-management
. Custom solutions
All models come in standard enclosures or can be
supplied for switchboards or DIN-rails.
Leasing with our partner VR LEASING is available hence.
EFFEKTA® family of batteries
3
Power Supplies
UPS classificlassifi
cation
UPS
cation
Power disturbance
Usable UPS class
VFI
VI
VFD
Power failure
>10ms
9
9
9
Voltage
fluctuations
<16 ms
9
9
9
Peaks
4-16ms
9
9
9
9
9
8
Over-voltage
9
9
8
Lightning
effects
9
8
8
Surge
<4ms
9
8
8
Two different technologies are used to provide a
consumer with uninterrupted power. The norms
EN 50091-3 and IEC 62040-3 serve to differentiate the
two technologies and assess their protection.
VI: UPS output voltage is independent of line voltage
or comparable modifications (voltage-stabilized)
VFI: UPS output voltage and frequency are
independent of line voltage and frequency or
comparable modifications.
Units: MT, MT-RM, ME, MI-RM, MTD, MTD-RM
Previously used definitions: online double-conversion,
continuous operation
Units: MH, MH-RM, MHD, MHD-RM, MKD, MKD-RM,
Pegasus, Quasar, Quasar II
4
Under-voltage
Previously used definitions: line-interactive,
single-conversion, delta conversion
VFD: UPS output frequency and output voltage
is dependent on line frequency and line voltage
or comparable modifications
Previous used definition: off-line, stand-by
UPS classification
Manual
Bypass (Option)
Input
Filter
Bidirectional
Inverter
Rectifier
Inverter
Input
Output
Output
Charger
Battery
Charger
Battery
Automatic
Bypass
LINE INTERACTIVE
Online Double-Conversion
Line-interactive systems (VI)
Online double-conversion (VFI)
. Short transfer time
. Bi-directional inverter
. Output voltage mostly pure sine wave /
. Securest UPS technology
. Protection against all types of disruption
. Stable output voltage
. No transform time
. Bypass function
in some cases modified sine wave
. Attractive price
. Booster-function
Areas of application:
Areas of application:
. Telecommunications
. CAD appliances
. SPS systems
. Small servers
. Telecommunications
. Servers
. Measuring systems
. Medical equipment (not life-support)
. Critical industrial and IT applications
Models:
ME series
MI-RM series (19“)
MT series
MT-RM series (19“)
MTD
MTD-RM
Models:
MH / MH-RM series (19”)
MHD / MHD-RM series (19”)
MKD / MKD-RM series (19”)
Pegasus
Quasar
Quasar II
.
.
.
.
.
.
.
.
.
.
.
.
5
Power Supplies
ME
ME
Line-interactive
400, 500, 600, 650, 800, 1000, 1500VA
The ME series offers as a succession model of the
proven MI series reliable protection before current
failures.
It was technically optimised and delivers optimum
protection and improved communication possibilities for
the electronic data processing with its digital circuit.
As a reasonable line-interactive model it is suitably
for the application on pc’s, workstations and network
components.
6
Features
‧ UPS-Classification VI-SY-333 in accordance with
IEC 62040-3
‧ Line-interactive technology
‧ Microprocessor-based regulation
‧ Automatic frequency synchronization
‧ Overload & short circuit protection
‧ RS-232, and SNMP via optional adapter
‧ optionally USB port
‧ Software-Suite PowerShut for UPS Management in
almost all current operating systems
‧ 24 months’ warranty
AC line-interactive UPS 400-3200VA
Rear view of ME 400-800VA
Models with USB
Rear view of ME 1000/1500
Rear view of ME 400-800VA
Models with RS232
Specifications
Specifications
Model
Input
Output (AC-Mode)
Voltage (VAC)
Frequency (Hz)
Synchronous zone
AVR Regulation
Output (INV.mode)
Voltage
Battery
DC start
Self diagnostics
Indicator
Frequency
Waveform
Capacity (VA/W)
Transfer time (ms)
Autonomy at full load in min.
Voltage
Type
Capacity
Quantity
Recharging time
Overload
Alarm
Short circuit
Noise suppression
Spike suppression
Battery over-drain
Modem / network
Audible
Environmental
Communication
Safety
conformance
400/225
6
12VDC
5Ah
1
AC mode
INVmode
Dimensions (HxWxD)
Net weight
Outlet (IEC)
Operation temp.
Operation humidity
Interface type
Safety standard
EMC / surge standard
Mark
ME 500
ME 600
+/-15%
LED
Protection
Physical
ME 400
5.4kgs
3
500/250
ME 650
170-280VAC
50/60Hz
45-65Hz
Boost +13%
Buck -13%
230VAC
50/60Hz±1%
Modified sinewave
650/325
ME 800
+/-10%
600/300
800/425
Typical 2-6ms
6
4
4
3
12VDC
12VDC
12VDC
12VDC
Maintainance free lead acid
7Ah
7Ah
7Ah
9.5Ah
1
1
1
1
8 hours to 90%
Yes
Upon power-on or software control
2 LEDs (AC mode, battery mode, fault)
ME 1000
ME 1500
+/-15%
1000/600
1500/900
Typical 4ms
5
4
24VDC
24VDC
7Ah
9.5Ah
2
2
6-8 hours to 90%
4 LEDs: line, backup, fault,
overload
Buzzer warning and fuse will open
Continuous buzzer warning
Buzzer warning and UPS-shutdown
>100% continuous warning
>110% UPS shut off after 10s
AC mode: input fuse and elctronic circuit, Inv. Mode: electronic circuit
EN50091-2
EN61000-4-5
Battery low warning and UPS shut off
RJ45
Line failure, battery low
Line failure, battery low, overload/fault
171x95x357mm
234x147x375mm
5.8kgs
5.8kgs
5.8kgs
6.4kgs
10.6kgs
14.2kgs
3
3
3
3
6
6
0-40°C
0-90% (non condensing)
0-95% (non condensing)
RS232 SUB D 9 / optionally USB
EN50091-1
EN50091-2, EN61000-3-2, EN61000-3-3
CE
7
Power Supplies
MI RM RM
MI
Line-interactive 600-1200VA
MI-Series is a cost-effective line-interactive system, that
protects sensitive consumers from power blackouts.
Areas of application are computers and smaller servers
and especially active network components in 19”
switchboards.
8
‧ UPS-classification VI-SY-333 in accordance
with IEC 62040-3
‧ Line-interactive technology
‧ Compact construction (only one 19” unit)
‧ Microprocessor-based regulation
‧ Automatic frequency synchronisation
‧ RS-232,opto-coupler and SNMP via adapter
‧ Software-Suite PowerShut for UPS Management in
almost all current operating systems
‧ 24 months’ warranty
AC line-interactive UPS 400-3200VA
MI 600 RM (rear view)
MI 1200 RM (rear view)
Specifications
Specifications
Type
Output
Power VA/Watt
Max current at 230 V (ampere)
Sockets
Output voltage
Frequency
Waveform
Transfer time
Input
Voltage
Frequency
Boost (+13%)
Buck (-13%)
Batteries
Full load
DC voltage
Accumulators
Type
Recharge time
Efficiency AC-AC
Auto-restart
Audible noise
Display
LED (UPS Status)
Acoustic alert
Protection
Overload
Lightning
EMC/LVD
Certificates and tests
Communication
Environment
Temperature
Humidity
Mechanics
Dimensions
Weight
MI 600 RM
MI 1200 RM
600/325
2.6
3 x nema sockets
1200/720
5.3
3 x nema sockets
230V ± 10%
50/60Hz auto
Step wave
Approx. 4 msec.
170-280VAC (230VAC)
50Hz (45-55) / 60Hz (55-65) auto
Yes
Yes
5 min
12VDC
7Ah-6V
5 min
24VDC
7Ah-6V
Lead-acid, maintenance-free (VRLA)
8-10 hours up to 90%
>94%
Yes
Noiseless
Line, Batt, Fault
Yes
Yes
ANSI/IEEE587 Class A
EN50091-2, EN50091-1
CE
RS232 / opto-coupler / SNMP via adapter
0-40°C (UPS without batteries)
0-95% (non-condensing)
1U x 19“ x 245mm deep
8.2kg
1U x 19“ x 350 mm deep
13.2kg
9
Power Supplies
MTD-series
MTD-series
NEU / NEW
MTD 1000
left: front
right: rear view
Description
Features
The MTD is EFFEKTA®s‘ further development of the lineinteractive MT-series.
It protects sensitive consumers from power blackouts,
spikes and other disruptions. Areas of application are
computers, remote telecommunications and other
computer-aided systems.
The unit‘s compact and stable construction has been
complemented by a convenient LCD display for easier
operation.
‧ UPS-classification VFI-SS-311 in accordance with
IEC 62040-3
‧ Line-interactive-technology
‧ User-friendly LCD-display
‧ Sine wave output
‧ Microprocessor controlled
‧ Automatic frequency detection
‧ Equiped with RS-232 port as standard
‧ Slot for optional adapters: relay-card, opto-coupler,
USB or SNMP
‧ Software-Suite PowerShut for UPS Management in
almost all current operating systems
‧ 36 months‘ warranty
Option: XL-Version with an possibility for easy extension
of the autonomy time through external battery packs
Left picture: clear control panel with back lighted LCD
display
10
AC line interactive UPS 400-3200VA
MTD is equiped with RS-232
slot interface, which can be
replaced with optional adapters:
relay-card, opto-coupler, USB
or SNMP.
Specifications
Specifications
Model
Power
Autonomy time
Input
Output
DC start-up
Switch time
Battery
Display
Audible alarm
Interface
Environment
Mechanic
Terminals
Safety/Enclosure
Power in VA
Power in W
100% load
50% load
Nominal load
Nominal input voltage
Input frequency range
Boost starting value / shut-off
Buck starting value / shut-off
Undervoltage warning value / all-clear
Overvoltage warning value / all-clear
Output voltage
Voltage tolerance
Line Mode
Battery Mode
Frequency tolerance
Line Mode
Battery Mode
Power factor
Voltage form
Efficiency
black start
typical
Nominal voltage
Blocks x nominal capacity / block
Type
Life time
Recharge time
LCD
LED
Battery Mode
Battery Low
fault
overload
Slot card
Temperature
Humidity
Operating height
Acoustic Noise
Casing
Protection class
Dimensions (H x W x D in mm)
Weight
Input
Output
DC-connection (for battery extension)
Standards
EMC
Norms
MTD 1000
1000
625
6min
15min
MTD 1500
MTD 2000
1500
2000
938
1250
6min
4min
15min
9min
230VAC
170~300VAC
45~70Hz Auto Sensing
195.5VAC ± 2% / 205.5VAC ± 2%
264.5VAC ± 2% / 254.5VAC ± 2%
170VAC ± 2% / 180VAC ± 2%
300VAC ± 2% / 290VAC ± 2%
Adjustable on LCD-display 220, 230, 240VAC
±15%
<3% RMS
50Hz oder 60Hz
±0.1Hz
0.625
Sine-wave
>80%
Yes
<4msec.
24VDC
36VDC
36VDC
4 x 9Ah
3 x 9Ah
3 x 9Ah
Maintenance free sealed lead-acid battery
5 years, optional 10 years
~5 h at 90%
UPS status, I/P&O/P Voltage & Frequency, Load %, Battery Voltage %, Temperature
Normal (green) / Warning (yellow) / Fault (red)
Beeping every 4 seconds
Beeping every second
Beeping continuously
Beeping twice per second
Standard with RS 232-interface
Optional cards: USB, relay, AS400, SNMP, Modbus
0°C – 40°C
0-95% non-condensing
<2000 above sea level
<55dBA @ 1m
Steel plate-tower / front plastic
IP 20
210 x 145 x 380
210 x 145 x 445
210 x 145 x 445
16.5kg
17.5kg
22.5kg
1 x IEC (10A)
3 x IEC
6 x IEC
only XL-versions
EN62040-1-1
EN62040-2
CE
11
Power Supplies
MTD-RM series
MTD-RM
series
NEU / NEW
1000, 1500, 2000VA
19” Rackmountable
upper model:
MTD 1000/1500 RM
bottom model:
MTD 2000 RM
Description
Features
The MTD-RM is EFFEKTA®s‘ further development of the
line-interactive MT-series.
It protects sensitive consumers from power blackouts,
spikes and other disruptions. Areas of application are
computers, remote telecommunications and other
computer-aided systems.
The unit‘s compact and stable construction has been
complemented by a convenient LCD display for easier
operation.
‧ UPS-classification VFI-SS-311 in accordance with
IEC 62040-3
‧ Line-interactive-technology
‧ User-friendly LCD-display
‧ Compact design: only 1U (1000/1500 VA)
and 2U (2000 VA)
‧ Sine wave output
‧ Automatic frequency detection
‧ Equiped with RS-232 port as standard
‧ Slot for optional adapters: relay-card, opto-coupler,
USB or SNMP
‧ Software-Suite PowerShut for UPS Management in
almost all current operating systems
‧ 36 months‘ warranty
Option: XL-Version with an possibility for easy extension
of the autonomy time through external battery packs
Left picture: clearly arranged control panel with back
lighted LCD display (2000 VA model)
12
AC line-ineractive UPS 400-3200VA
MTD-RM is with its 1U (1000 and 1500VA, upper picture) and 2U (2000VA, buttom
picture) one of the most compact 19” line-interactive UPS systems in this power
stage.
MTD is equiped with RS-232
slot interface, which can be
replaced with optional adapters:
relay-card, opto-coupler, USB
or SNMP.
Specifications
Specifications
Model
Power
Autonomy time
Input
Output
DC start-up
Switch time
Battery
Display
Audible alarm
Interface
Environment
Mechanic
Terminals
Safety/Enclosure
Power in VA
Power in W
100% load
50% load
Nominal load
Nominal input voltage
Input frequency range
Boost starting value / shut-off
Buck starting value / shut-off
Undervoltage warning value / all-clear
Overvoltage warning value / all-clear
Output voltage
Voltage tolerance
Line Mode
Battery Mode
Frequency tolerance
Line Mode
Battery Mode
Power factor
Voltage form
Efficiency
black start
typical
Nominal voltage
Blocks x nominal capacity / block
Type
Life time
Recharge time
LCD
LED
Battery Mode
Battery Low
fault
overload
Slot card
Temperature
Humidity
Operating height
Acoustic Noise
Casing
Protection class
Dimensions (H x W x D in mm)
Weight
Input
Output
DC-connection (for battery extension)
Standards
EMC
Norms
MTD 1000 RM
1000
625
3min
8min
MTD 1500 RM
MTD 2000 RM
1500
2000
938
1250
2min
4min
5min
9min
230VAC
170~300VAC
45~70Hz Auto-Sensing
195.5VAC ± 2% / 205.5VAC ± 2%
264.5VAC ± 2% / 254.5VAC ± 2%
170VAC ± 2% / 180VAC ± 2%
300VAC ± 2% / 290VAC ± 2%
Adjustable on LCD Display 220, 230, 240VAC
± 15%
< 3% RMS
50Hz or 60Hz
± 0.1Hz
0.625
Sine wave
> 80%
Yes
< 4msec.
24VDC
24VDC
36VDC
4 x 6V / 7Ah
4 x 6V / 7Ah
3 x 12V / 9Ah
Maintenance free sealed lead-acid battery
5 years, optional 10 years
5h at 90%
UPS status, I/P&O/P Voltage & Frequency, Load %, Battery Voltage %, Temperature
Normal (green) / Warning (yellow) / Fault (red)
Beeping every 4 seconds
Beeping every second
Beep continuously
Beeping twice per second
Standard with RS 232-interface.
Optional cards: USB, relay, AS400, SNMP, Modbus
0°C – 40°C
0-95% non-condensing
< 2000m above sea level
< 55dBA @ 1m
Steel plate-tower / front plastic
IP 20
44 (1U) x 440 (19”) x 515
44 (1U) x 440 (19”) x 515
88 (2U) x 440 (19”) x 465
18kg
20.2kg
24.5kg
1 x IEC (10A)
3 x IEC
6 x IEC
only XL-versions
EN62040-1-1
EN62040-2
CE
13
Power Supplies
MT
MT
Line-Interactive 700, 1000, 1500, 2000, 3200VA
The MT Series is a progressive line-interactive UPS, that
protects sensitive consumers from power blackouts,
spikes and other disruptions. Areas of application are
computers, remote telecommunications and other computer-aided systems. The unit’s compact and stable construction provides additional security and flexibility of use.
All models
also available in black
14
‧ UPS classification VI-SS-311 in accordance
with IEC 62040-3
‧ Line-interactive technology
‧ Microprocessor-based regulation
‧ Pure sine wave output
‧ Temperature sensor
‧ Automatic frequency synchronisation
‧ RS-232, opto-coupler and SNMP via adapter
‧ Software-Suite PowerShut for UPS Management in
almost all current operating systems
‧ 36 months’ warranty
AC line-interactive UPS 400-3200VA
MT 700 (rear view)
MT 1000-2000 (rear view)
MT 3200 (rear view)
Specifications
Specifications
Type
Output
Power VA/Watt
Max current at 230 V (ampere)
Sockets
Output voltage
Frequency
Waveform
Input
Voltage
Frequency
Boost (+13%)
Buck (-13%)
Batteries
Full load
DC voltage
Accumulators
Type
Recharge time
Test
Efficiency AC-AC
DC-start-up (black-start)
Auto-restart
Overload
Audible noise
LED display
UPS status
Acoustic alert
Protection
Overload
Lightning
EMC/LVD
Certificates and tests
Communication
Environment
Temperature
Humidity
Mechanics
Dimensions (HxWxD in mm)
Weight
MT 700
MT 1000
MT 1500
MT 2000
MT 3200
700/470
3.0
2 x nema sockets
1000/670
4.3
4 x nema sockets
1500/1000
6
4 x nema sockets
230V ± 3%
50/60Hz ± 0.1% auto
Pure sine wave
2000/1200
7.8
4 x nema sockets
3200/2000
13.9
6 x nema sockets
171-278VAC (230VAC)
50Hz (44-55) / 60Hz (55-65) auto
Yes
Yes
8min
24VDC
10min
36VDC
<40dB(A)
10min
48VDC
7Ah-12V
Lead-acid, maintenance-free (VRLA)
8-10 hours up to 90%
Automatic or test key
>95%
Yes
Yes
110% for 10sec.
<45dB(A)
10min
60VDC
8min
2x48VDC
Line, On Bat, On AVR, Bat Weak, Fault, Overload, Load Level
Yes
Yes
ANSI/IEEE587 Cat.A
EN50091-2, EN50091-1
CE
black models optionally with RS232 + USB / opto-coupler / SNMP via adapter
0-40°C (UPS without batteries)
0-95% (non-condensing)
160x120x360
13.3kg
200x160x450
19.5kg
200x160x450
22.6kg
200x160x450
26.2kg
290x160x530
45.0kg
15
Power Supplies
MT RM RM
MT
Line-interactive 700, 1000, 1500, 2000, 3200VA
‧
The MT Series is a progressive line-interactive UPS,
that protects sensitive consumers from power blackouts,
spikes and other disruptions. Areas of application are
computers, remote telecommunications and other
computer-aided systems. The enclosures of the MT
Series are almost the most robust and compact racks
on the UPS market (starting from a 300mm mounting
depth).
‧
‧
‧
‧
‧
‧
‧
‧
3200VA model
16
UPS classification VI-SS-311 in accordance
with IEC 62040-3
Line-interactive technology
Microprocessor-based regulation
Pure sine wave output
Temperature sensor
Automatic frequency synchronisation
RS-232, opto-coupler and SNMP via adapter
Software-Suite PowerShut for UPS Management in
almost all current operating systems
36 months’ warranty
AC line-interactive UPS 400-3200VA
MT 700-1500 RM (rear view)
MT 2000 RM (rear view)
MT 3200 RM (rear view)
Specifications
Specifications
Type
Output
Power VA/Watt
Max current at 230V (ampere)
Sockets
Output voltage
Frequency
Waveform
Input
Voltage
Frequency
Boost (+13%)
Buck (-13%)
Batteries
Full load
DC voltage
Accumulators
Type
Recharge time
Test
Efficiency AC-AC
DC-start-up (black-start)
Auto-Restart
Overload
Audible noise
LED display
UPS status
Acoustic alert
Protection
Overload
Lightning
EMC/LVD
Certificates and tests
Communication
Environment
Temperature
Humidity
Mechanics
Dimensions (U x 19” x D in mm)
Weight
MT 700 RM
MT 1000 RM
MT 1500 RM
MT 2000 RM
MT 3200 RM
700/450
3
2 x three-core sockets
1000/670
4.3
2 x three-core sockets
1500/1000
6
2 x three-core sockets
230V ± 3%
50/60Hz ± 0.1% auto
Pure sine wave
2000/1200
7.8
2 x three-core sockets
3200/2000
13.9
8 x nema sockets
171-278VAC (230VAC)
50Hz (45-55) / 60Hz (55-65) auto
Yes
Yes
8min
24VDC
10min
36VDC
10min
48VDC
7Ah-12V
Lead-acid, maintenance-free ( VRLA)
8-10 up to 90%
Automatic or test key
>95%
Yes
Yes
110% for 10sec.
<45dB(A)
<35dB(A)
10min
60VDC
8min
2 x 48VDC
Line, On Bat, On AVR, Bat Weak, Fault, Overload, Load Level
Yes
Yes
ANSI/IEEE587 Cat.A
EN50091-2, EN50091-1
CE
RS232 / opto-coupler / SNMP via adapter
0-40°C (UPS without batteries)
0-95% (non-condensing)
3U x 19“ x 300
15kg
3U x 19“ x 300
19.6kg
3U x 19“ x 300
24kg
3U x 19“ x 350
29.5kg
3U x 19“ x 480
49.5kg
17
Power Supplies
MKD
MKD
MKD 1000
To the right: Rear view
To the left: Front view
Description
Features
The MKD UPS is a modern, microprocessor controlled
online double-conversion UPS.
The MKD UPS features electronic bypass and is to be
applied with supersensitive and critical applications like
servers, workstations, metrological or industrial systems.
‧ UPS-classification VFI-SS-111 (IEC 62040-3)
‧ Extraordinary wide voltage range
(118-300VAC @ <50% load)
‧ User-friendly LCD-Panel
‧ Online double-conversion
‧ Sine wave output
‧ Microprocessor controlled
‧ Automatic frequency detection
‧ Equipped with RS-232 port as standard
‧ Slot for optional adapters: relay card, opto-coupler,
USB or SNMP
‧ Software-Suite PowerShut for UPS Management in
almost all current operating systems
‧ Optional XL-version with external battery cabinets
‧ 36 months’ warranty
Left hand picture: 2000 VA XL-version with optional
external battery cabinet (right hand casing)
18
AC online double-conversion UPS 700-3000VA
Rear view MKD 700/1000
Rear view MKD 2000
Rear view MKD 3000
Specifications
Specifications
Type
Power
Autonomy time
Input
Output
Overload
Bypass
Battery
Prot./standards
Environment
Mechanic
Terminals
Communication
Power in VA
Power in W
Nominal load
Nominal input voltage
Input voltage range
Input frequency range
Max. input current
Powerfactor (cos φ)
Output voltage
Deviation statically
Waveform
Output frequency
Harmonic distortion / linear load
Crest factor acc. EN 50091-1
Max. output current in A
Efficiency at nom. Load
Normal operation mode
Normal / battery mode
Short circuit current
Voltage range
Transfer time
Nom. Voltage
Blocks
Nom. capacity/block
Type
Life time
Recharge time
Battery test
Appliances
Safety
EMC
Temperature (operational)
Temperature (storage)
Humidity
Altitude (operational)
Casing
Protection class
Dimensions (H x W x D in mm)
Weight
Input
Output
Input fuse
DC-terminals (for ext. battery extension)
Socket Sub-D 9, slot
MKD 700
700
490
10
MKD 1000
1000
700
7
MKD 2000
2000
1400
7
MKD 3000
3000
2100
6
230VAC
118~300VAC (0-50% load), 140~300VAC (50-70% load), 160~300VAC (70-100% load)
50 or 60Hz +/-8%
s. terminals > input fuse
>0.95
>0.97
adjustable 220, 230, 240VAC
+/-2%
Sine wave
50 or 60Hz (synchronized line-mode / ± 0.5% battery mode)
< 3% @ full load
< 4% @ full load
3:1 / (surge current / RMS-current)
3
4.3
8.7
13
>85% AC-AC / >83% DC-AC
Bypass transfer @ load > 110%
105-150% for 30Sec. / 150% for 200mSec
3 x Inenn for (120mSec)
Adjustment range min. 156-196V, max. 233-273V
2.5mSec inverter to bypass
36VDC
36VDC
96VDC
96VDC
3
8
8
3
7Ah
7Ah
7Ah
7Ah
Lead acid, maintenance free batteries
App. 5 years (subject to environment)
App. 5h up to 90%
Manually via button or via software
Electron. overload- and short circuit-prot., temperature monitoring, deep discharge protection…
CE / EN62040-1
EN 62040-2
0°C – 40°C
0°C – 40°C
20-95% not condensing
<2000m o. NN
Steel plate / front plastics
IP20
220x160x400
220x160x400
352x200x450
352x200x450
15kgs
15kgs
34kgs
35kgs
1 x IEC (10A)
1 x IEC (16A)
4 x IEC
6 x IEC
3 x IEC (10A)
1 x IEC (16A)
6.3A
6.3A
10A
16A
Only XL-models
RS 232-interface / Optionally available cards for slot: USB, relays, SNMP
19
Power Supplies
MKD-RM
MKD-RM
Right hand picture:
MKD 2000/3000 RM
Description
Features
The MKD UPS is a modern, microprocessor controlled
online double-conversion UPS.
With its extraordinary compact design MKD RM can
specially be used in racks with a minimum of space
capacity.
‧
The MKD UPS features an electronic bypass and is to
be applied with supersensitive and critical applications
like servers, workstations, metrological or industrial
systems.
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
Bottom picture: MKD 700/1000 RM
20
UPS-classification VFI-SS-111 (IEC 62040-3)
Extraordinary wide voltage range
(118-300VAC @ <50% load)
User-friendly LCD-Panel
Compact design: only 2U per slot
already from 415mm depth (700/1000VA)
Online double-conversion
Sine wave output
Microprocessor controlled
Automatic frequency detection
Equipped with RS-232 port as standard
Slot for optional adapters: relay card, opto-coupler,
USB or SNMP
Software-Suite PowerShut for UPS Management in
almost all current operating systems
Optional XL-version with external battery cabinets
36 months’ warranty
AC online double-conversion UPS 700-3000VA
Rear view of MKD 700/1000 RM (internal batteries)
Rear view of MKD 2000 RM (electronics only)
Rear view of MKD 3000 RM (electronics only)
Rear view of battery pack for MKD 2000/3000 RM
(same type for XL models)
Specifications
Specifications
Type
Power
Autonomy time
Input
Output
Overload
Bypass
Battery
Prot./standards
Environment
Mechanic
Terminals
Communication
Power in VA
Power in W
Nominal load
Nominal input voltage
Input voltage range
Input frequency range
Max. input current
Powerfactor (cos φ)
Output voltage
Deviation statically
Waveform
Output frequency
Harmonic distortion / linear load
Crest factor acc. EN 50091-1
Max. output current in A
Efficiency at nom. Load
Normal operation mode
Normal / battery mode
Short circuit current
Voltage range
Transfer time
Nom. Voltage
Blocks
Nom. capacity/block
Type
Life time
Recharge time
Battery test
Appliances
Safety
EMC
Temperature (operational)
Temperature (storage)
Humidity
Altitude (operational)
Casing
Protection class
Dimensions (H x W x D in mm)
Weight
Input
Output
Input fuse
DC-terminals (for ext. battery extension)
Socket Sub-D 9, slot
MKD 700 RM
700
490
10
MKD 1000 RM
1000
700
7
MKD 2000 RM
2000
1400
7
MKD 3000 RM
3000
2100
6
230VAC
118~300VAC (0-50% load), 140~300VAC (50-70% load), 160~300VAC (70-100% load)
50 or 60Hz +/-8%
s. terminals > input fuse
>0.95
>0.95
adjustable 220, 230, 240VAC
+/-2%
Sine wave
50 or 60Hz (synchronized line-mode / ± 0.5% battery mode)
< 3% @ full load
< 3% @ full load
3:1 / (surge current / RMS-current)
3
3
3
3
>85% AC-AC / >83% DC-AC
Bypass transfer @ load > 110%
105-150% for 30Sec. / 150% for 200mSec
3 x Inenn for (120mSec)
Adjustment range min. 156-196V, max. 233-273V
2.5mSec inverter to bypass
36VDC
36VDC
96VDC
96VDC
3
3
8
8
7Ah
7Ah
7Ah
7Ah
Lead acid, maintenance free batteries
App. 5 years (subject to environment)
App. 5h up to 90%
Manually via button or via software
Electron. overload- and short circuit-prot., temperature monitoring, deep discharge protection…
CE / EN62040-1
EN 62040-2
0°C – 40°C
0°C – 40°C
20-95% not condensing
<2000m o. NN
Steel plate / front plastics
IP20
2U x 19“ x 415mm
2U x 19“ x 415mm
2 x 2U x 19“ x 465mm
2 x 2U x 19“ x 465mm
15kgs
15kgs
34kgs
35kgs
1 x IEC (10A)
1 x IEC (16A)
4 x IEC
4 x IEC
2 x IEC (10A)
1 x IEC (16A)
6.3A
6.3A
10A
16A
optional
RS 232-interface / Optionally available cards for slot: USB, relays, SNMP
21
Power Supplies
MH
MH
Online double-conversion
700, 1000, 1500, 2000, 3000VA
‧
‧
The MH Series is a state of the art, microprocessorcontrolled online double-conversion UPS solution
with an electronic bypass for supersensitive and
critical applications such as servers, workstations, and
measuring or industrial machines.
‧
‧
‧
‧
‧
‧
‧
‧
‧
UPS-classification VFI-SS-111 in accordance
with IEC 62040-3
Online double-conversion
Auto-select input frequency
Pure sine wave output
Microprocessor-based regulation
Automatic frequency synchronisation
Intelligent battery management
RS-232, opto-coupler and SNMP via adapter
Software-Suite PowerShut for UPS Management in
almost all current operating systems
Temperature sensor
36 months’ warranty
MH 2000 display- “line-mode / 20% load“
MH 2000 display- “battery-mode / batteries loaded“
MHD series with RS232
+ USB + LCD-Display
22
MH 700 display- “battery-mode /
batteries at 3/4 capacity“
AC online double-conversion UPS 700-3000VA
MH 700-1500 (rear view)
MH 2000-3000 (rear view)
Specifications
Specifications
Type
Output
Power VA/Watt
Max current at 230V
Sockets
Output voltage
Frequency
Waveform
Input
Voltage
Frequency
Batteries
Full load
DC-voltage
Accumulators
Type
Recharge time
Test
PFC
Efficiency AC-AC
DC-start-up (black-start)
Auto-restart
Overload
Audible noise
LED display
USV status
Load status
Audible alert
Protection
Overload
Lightning
EMC/LVD
Certificates and tests
Communication
Environment
Temperature
Humidity
Mechanics
Dimensions (HxWxD in mm)
Weight
MH 700
MH 1000
MH 1500
MH 2000
MH 3000
700/490
3.0A
2 x three-core sockets
1000/700
4.3A
2 x three-core sockets
1500/975
6A
2 x three-core sockets
230V ± 2%
50/60Hz ± 0.1% auto
Pure sine wave
2000/1400
8.7A
3 x three-core sockets
3000/2100
13A
3 x three-core sockets
160-275VAC (230VAC)
45-65Hz
10min
24VDC
7Ah-12V
10min
36VDC
<45dB(A)
6min
36VDC
7/9.5Ah-12V
Lead-acid, maintenance-free (VRLA)
8-10 up to 90%
Automatic or test key
Yes
>85%
Yes
Yes
110% for 10-25sec.
<50dB(A)
10min
72VDC
7Ah-12V
10min
96VDC
<47dB(A)
LINE; BYPASS; INV; FAULT; BAT-LEVEL; LOAD-LEVEL; BAT.(MH 2000/3000)
20%, 50%, 100%, OVERLOAD
Yes
Yes
ANSI/IEEE587 Cat.A
EN50091-2, EN50091-1
CE
RS232 / opto-coupler / SNMP via adapter / MHD Series with RS232 + USB + LCD-Display (black cabinet)
0-40°C (UPS without batteries)
0-95% (non-condensing)
190x140x440
12.5kg
190x140x440
15kg
190x140x440
15.2kg
320x190x500
32.4kg
320x190x500
38.2kg
23
Power Supplies
MH RM RM
MH
MH 2000-3000 RM incl. battery cabinet
Online double-conversion 19“
700, 1000, 1500, 2000, 3000VA
The MH RM is a state of the art, microprocessor-controlled
online double-conversion solution with an electronic
bypass for supersensitive and critical application such
as servers, workstations and measuring or industrial
machines. The enclosures of this series are amongst
the most robust and compact racks on the UPS market
(starting from a 390mm mounting depth).
. UPS-classification VFI-SS-111 according IEC 62040-3
. Online-Double conversion
. Auto select input frequency
. Pure sine wave output
. Microprocessor based regulation
. Automatic frequency synchronisation
. Intelligent battery management
. RS-232, opto-coupler and SNMP via Adapter
. Software-Suite PowerShut for UPS Managemnt in
almost all current operating systems
. Temperature sensor
. 36 months warranty
MH 2000 display- “line-mode / 20% load“
MH 2000 display- “battery-mode / batteries loaded“
MH 700 display- “battery-mode /
batteries at 3/4 capacity“
24
MHD-RM series with RS232
+ USB + LCD-Display
AC online double-conversion UPS 700-3000VA
MH 700-1500 RM (rear view)
MH 700-1500 RM (front view)
MH 2000-3000 RM (with battery cabinet) (rear view)
Battery cable
Specifications
Specifications
Type
Output
Power VA/Watt
Max current at 230V
Sockets
Output voltage
Frequency
Waveform
Input
Voltage
Fequency
Batteries
Full load
DC voltage
Accumulators
Type
Recharge time
Test
PFC
Efficiency AC-AC
DC-start-up (black-start)
Auto Restart
Overload
Audible noise
LED display
UPS status
Load status
Audible alert
Protection
Overload
Lightning
EMC/LVD
Certificates and tests
Communication
Environment
Temperature
Humidity
Mechanics
Dimensions (U x 19“ x D in mm)
Weight
Dimensions battery-pack (U x W x D in mm)
Weight battery-pack
MH 700 RM
MH 1000 RM
MH 1500 RM
MH 2000 RM
MH 3000 RM
700/490
3.0A
2x three-core sockets
1000/700
4.3A
2x three-core sockets
1500/975
6A
2x three-core sockets
230V ± 2%
50/60Hz ± 0.1% auto
Pure sine wave
2000/1400
8.7A
2x three-core sockets
3000/2100
13A
2x three-core sockets
160-275VAC (230VAC)
45-65Hz
10min
24VDC
7Ah-12V
10min
36VDC
7Ah-12V
< 45dB(A)
min
10min
36VDC
72VDC
9.5Ah-12V
7Ah-12V
Lead-acid, maintenance-free (VRLA)
8-10 hours up to 90%
Automatic or test key
Yes
>85%
Yes
Yes
110% for 10-25sec.
< 50dB(A)
10min
96VDC
7Ah-12V
< 45dB(A)
LINE; BYPASS; INV; FAULT; BAT-LEVEL; LOAD LEVEL; BAT.(MH 2000/3000)
20%, 50%, 100%, OVERLOAD
Yes
Yes
ANSI/IEEE587 Cat.A
EN50091-2, EN50091-1
CE
RS232 / opto-coupler / SNMP via adapter
0-40°C (UPS without batteries)
0-95% (non-condensing)
2U x 19“ x 390
16.4kg
-
2U x 19“ x 390
19.3kg
-
2U x 19“ x 420
19.7kg
-
2U x 19“ x 480
15.4kg
2U x 19“ x 395
25.4kg
2U x 19“ x 480
15.5kg
2U x 19“ x 395
31kg
25
Power Supplies
MH 60006000
MH
MH 6000 incl battery cabinet
Online double-conversion 6000VA with
1-phase input
‧
‧
MH 6000 is a progressive development of UPS MH
5000/7000. With its fast DSP (Digital Signal Processing)
controller it offers a new sine-wave quality and high
performanc in controlling input & output. Digitalisation of
all circuits accelerates, optimises and reduces the number
of components and increases the standard lifetime of
important parts.
‧
‧
‧
‧
‧
‧
‧
‧
26
The reliability and availability of the power line has been
improved considerably compared to existing switching
technologies.
‧
A wide range of easy-to-use extension options enable the
UPS to be integrated easily for any application.
Its modern design, compact dimensions and low audible
noise make it suitable for all kinds of offices.
‧
‧
UPS-classification VFI-SS-111 in accordance
with IEC 62040-3
True Online-Double conversion
Digital control processor
Dual input loops
Smart eco mode
Programmable frequency processor
Easy-to-set user personalization
Power range and runtime scalability
RS-232 + EPO (equipped as standard)
Additional slot for optional relaycard or SNMP-adapter
Management software enclosed
24 months’ warranty
Optional easy-to-use parallel installation
‧ Optional galvanic isolation transformator
‧ Optional hot swappable batteries
AC large UPS 6-300kVA
MH 6000 Display
MH 6000 (rear view)
MH 6000 (adapter slot)
Specifications
Specifications
Type
Power
VA Rating
Wattage
Cos phi
Input
Voltage
Frequency
Current in Ampere
PFC (power-factor-correction)
Output
Voltage
Current in Ampere
Overload
Frequency
Waveform
Crest factor
Harmonic distortion
Fault reaction
Efficiency
BatterIES
Autonomy time (100% load)
DC-voltage
Number of blocs
Capacity per unit
Type
Expected lifetime
Recharge time
Bypass (SBS)
Nominal voltage
Overload
Manuel bypass (standard)
Communication
Display
Alarms
Interface
SNMP
Certificates and tests
Security
EMV / RFI
Mechanics / Environment
Casing
Temperature
Humidity
Audible noise
MH 6000
6000
4200
0.7
160-280VAC
45-65Hz
25
yes
200/220/230/240VAC selectable, ± 2%
21
110% for 125 sec./140% for 10sec. - 2 cycles before switching to bypass
50/60Hz (± 0,2Hz in backup mode)
Pure sine wave
3:1
<3% with linear load
Automatic switch to bypass or disconnection (in case of overload, overheat or short circuit)
up to 91% / in eco mode up to 98%
>8min.
240VDC
20
7Ah
Lead acid, maintenance free (VRLA)
5 years (optional 10 years)
<4 hours up to 90%
1 x 230V (160-280V)
200% for 160msec.
Yes
Status on LCD + LCD: Line Mode, Backup Mode, ECO Mode, Bypass supply, Battery Low,
Battery Bad/Disconnected, Overload, Transferring with Interruption & UPS Fault
Readings on LCD: Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load percentage,
Battery Voltage & Inner Temperature
Audible and visual: Line Failure, Battery Low, Transfer to Bypass, System Fault Condition
Standard RS232 interface, Communication slots options: 2nd RS232 & EPO, USB & EPO, RS 485 & EPO,
Relay contact & EPO, SNMP/WEBcard, etc.
Optional via software or external/slot adaptor
IEC 950/EN 50091-1, CE
EN 55022 « A »
Tower / colour black / protection type IP 21 / 748 x 290 x 645mm (H x W x D) / app. 86kg
0-40°C (UPS without battery)
10-90% (non condensing)
55dB(A) in 1m distance (depends on load and temperature)
27
Power Supplies
MH 60006000
RM
MH
RM
6000VA online double-conversion with single-phase
output
‧
UPS-classification VFI-SS-111 in accordance
with IEC 62040-3
True online double-conversion
Digital control processor
LCD display, 30 different status messages
Sine wave current consumption
Pure sine wave output
Digital battery management
Modular battery extension
RS-232 + EPO (equipped as standard)
Additional slot for optional relaycard or SNMP-adapter
Management software enclosed
24 months’ warranty
‧
Optional external bypass
‧
‧
MH 6000 RM is a fully digital UPS from EFFEKTA .
With its fast DSP (Digital Signal Processing) controller it
offers a new sine-wave quality and high performances in
controlling input and output.
Digitalisation of all circuits accelerates, optimises and
reduces the number of components and increases the
standard lifetime of important parts.
®
‧
‧
‧
‧
‧
‧
‧
‧
The reliability and availability of the power line has been
improved consideravly compared to existing switching
technologies.
‧
A wide range of easy-to-use extensions enable the UPS
to be integrated easily for any application.
External bypass with optional web manager
28
AC large UPS 6-300kVA
rear view:
Electronic-module at top,
battery cabinet middle
and bottom
Specifications
Specifications
Type
Power
VA Rating
Wattage
Cos phi
Input
Voltage
Frequency
Current in Ampere
PFC (power-factor-correction)
Output
Voltage
Current in Ampere
Overload
Frequency
Waveform
Crest factor
Harmonic distortion
Fault reaction
Efficiency
BatterIES
Autonomy time (100% load)
DC-voltage
Number of blocs
Capacity per unit
Type
Expected lifetime
Recharge time
Bypass (SBS)
Nominal voltage
Overload
Manuel bypass (standard)
Communication
Display
Alarms
Interface
SNMP
Certificates and tests
Security
EMV / RFI
Mechanics / Environment
Casing
Dimensions UPS (H x W x D in mm)
Dimensions battery pack (H x W x D in mm)
Weight
Temperature
Humidity
Audible noise
MH 6000 RM
6000
4200
0.7
160-280VAC
45-65Hz
25
yes
200/220/240VAC selectable, ± 2%
21
<105% : 160 s >105% … < 150% : 40ms >150% :immediately
50/60Hz (± 0,2Hz in backup mode)
Pure sine wave
3:1
<3% with linear load
Automatic switch to bypass or disconnection (in case of overload, overheat or short circuit)
up to 91% / in eco mode up to 98%
>8min.
240VDC
20
9,5Ah
Lead acid, maintenance free (VRLA)
5 years (optional 10 years)
<8 hours up to 90%
1 x 230V (160-280V)
200% for 160msec.
Yes
Status on LCD + LCD: Line Mode, Backup Mode, ECO Mode, Bypass supply, Battery Low,
Battery Bad/Disconnected, Overload, Transferring with Interruption & UPS Fault
Readings on LCD: Input Voltage, Input Frequency, Output Voltage, Output Frequency, Load percentage,
Battery Voltage & Inner Temperature
Audible and visual: Line Failure, Battery Low, Transfer to Bypass, System Fault Condition
Standard RS232 interface
Communication slots options: 2nd RS232 & EPO, USB & EPO, RS 485 & EPO,
Relay contact & EPO, SNMP/WEBcard, etc.
Optional via software or external/slot adaptor
IEC 950/EN 50091-1, CE
EN 55022 « A »
19” rack mountable / colour black / protection type
3U / 19“ / 545mm
2 x (2U / 19“ / 515mm)
19.5 + 36.5 + 36.5
0-40°C (UPS without battery)
10-90% (non condensing)
50dB(A) in 1m distance (depends on load and temperature)
29
Power Supplies
MHD 10-20kVA
MHD
10-20kVA
Online double-conversion 10-20kVA
with 1-phase (10kVA) input
or 3-phase (10, 15, 20kVA) input
The MHD 10-20kVA with its fast DSP (Digital Signal
Processing) controller offers a new sine-wave quality
and high performanc in controlling input & output.
Digitalisation of all circuits accelerates, optimises and
reduces the number of components and increases the
standard lifetime of important parts.
The reliability and availability of the power line has been
improved considerably compared to existing switching
technologies.
A wide range of easy-to-use extension options enable
the UPS to be integrated easily for any application.
Its modern design and compact dimensions make it
suitable for all kinds of offices.
30
Features & Advantages
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
UPS-classification VFI-SS-111 (IEC 62040-3)
Online Double-Conversion
Multiple Microprocessor design base
Detachable control panel with LCD
Wide input voltage range
Optionally parallel design
DC start and automatic self-diagnostic function
High capacity of battery through extension packs
Slot for alternatively RS232, SNMP or relay card
High efficiency design
Low heat dissipation in long term operation
24 months' warranty
AC large UPS 6-300kVA
MHD 10kVA display
UPS electronics rear view
Specifications
Specifications
Input
Output
Battery
Transfer Time
Indicator
Removable
Audible Alarm
Interface
Certificates
Environment
Weight
Dimension
Model
Capacity
Nominal Voltage
Voltage Range
Frequency
Power Factor
Voltage
Frequency
Wave-form
Distortion
Crest Ratio
Type
Capacity
Back-up
Built-In Charger
Charger (Option)
Charging Voltage
Recharger Time
AC-DC to Bypass
LCD
LED
Battery Mode
Battery Low
Overload
Fault
RS-232 Interface
SNMP Intelligent Slot (Option)
engineer standards
Temperature
Humidity
Acoustic Noise (at 1M)
w/ battery
w/o battery
(HxWxD)mm
MHD 10kVA 1-1
10KVA/7KW
Single ph. 230Vac
176~276Vac
MHD 10kVA 3-1
10 kVA/7kW
MHD 15 kVA 3-1
MHD 20kVA 3-1
15kVA/10,5kW
20kVA/14kW
3 ph. 380Vac
304~478Vac
50Hz or 60Hz +/- 8%
≥0.98
≥0.95
220 / 230 / 240Vac +/- 1%
Synchronized (Line mode), 50Hz or 60Hz +/- 0.5Hz (Battery Mode)
True Sine wave
2% (Linear Load), 6% (Non-Linear Load)
3:1
Maintenance free sealed lead-acid battery
12V / 9Ah * 20pcs
On request
On request
On request
4min
On request
On request
On request
2A
4,2A
4,2A
4,2A
4.2A
On request
On request
On request
274Vdc +/- 0.5V
On request
On request
On request
7-8 hrs to 90% of full capacity after full load discharge
0 ms
UPS status, I/P&O/P Voltage& Frequency, Load %, Battery Voltage & %, Temperature, Model Spec.,
Event Log
Normal (Green), Warning (Yellow), Fault (Red)
Beeping every 4 seconds
Beeping every seconds
Beeping twice per second
Beep Continuously
Yes
Power management via optional SNMP management and web browser
CE
0-40 degree C; 32-104 degree F
20-90% non-condensing
< 55dBA
< 55dBA
< 60dBA
< 60dBA
94kgs
Batteries on principle in external cabinet
38kgs
38,5kgs
55kgs
55kgs
717x260x570
717x260x570
717x260x570
717x260x570
31
Power Supplies
MHD RM 10kVA
MHD
RM 10kVA
NEU / NEW
Right hand picture:
Front view
MHD RM 10kVA incl.
battery cabinet
19“-online double-conversion UPS
10.000VA with 1-phase input
The MHD 10 RM offers a new sine-wave quality and
high performance in controlling input & output with its
modern electronics.
The depth of only 570 mm is one of the smallest on
the UPS market. This compactness and the other
advantages make the MHD 10 RM suitable for all
applications, that presuppose highest reliability and
minimal required space of the UPS system.
The reliability and availability of the power line has been
improved considerably compared to existing switching
technologies.
A wide range of easy-to-use extension options enable
the UPS to be easily dimensioned and professionally
integrated for any application.
Bottom picture: optionally external bypass
32
Features
‧ UPS-classification VFI-SS-111 (IEC 62040-3)
‧ Online double-conversion with sine-wave output
‧ Compact design with 19“ width, 4U (electronics), and
only 570 mm depth
‧ User-friendly LCD-Panel
‧ Microprocessor controlled
‧ Wide voltage range
‧ Sine wave current consumption
‧ DC start and automatic self-diagnostic function
‧ Modular battery extension
‧ RS-232 (euipped slot as standard)
‧ Slot for optional relaycard, USB or SNMP-adapter
‧ High efficiency design
‧ Low heat dissipation in long term operation
‧ 24 months‘ warranty
AC large UPS 6-300kVA
rear view
MHD 10 RM display
Specifications
Specifications
Input
Output
Battery
Transfer Time
Indicator
Audible Alarm
Interface
Environment
Weight
Dimension
Model
Capacity
Nominal Voltage
Voltage Range
Frequency
Power Factor
Voltage
Frequency
Wave-form
Distortion
Crest Ratio
Type
Capacity
Back-up
Built-In Charger
Charging Voltage
Recharging Time
AC-DC to Bypass
LCD
LED
Battery Mode
Battery Low
Overload
Fault
RS-232 interface
Options
Temperature
Humidity
Operating height
Acoustic Noise (at 1M)
w/battery (standard)
w/o battery
UPS elektronics
Battery cabinet
MHD 10 RM
10kVA / 7kW
1-ph. 230VAC (L, N, P)
176~276VAC
50 or 60Hz ± 8%
≥ 0,98
220 / 230 / 240VAC ± 1%
Synchronized (Line mode), 50Hz or 60Hz ± 1% (Battery Mode)
Sine-wave
< 2% (Linear load), < 6% (non-linear load)
3:1
Maintenance free sealed lead-acid battery
12V, 9Ah
4min, extendible
2A
274VDC ± 0,5V
7-8h at 90% of full capacty after full load discharge
0ms
UPS status, I/P&O/P Voltage & Frequency, Load %, Battery Voltage %, Temperature
Model Spec., Event Log
Normal (green), Warning (yellow), Fault (red)
Beeping every 4 seconds
Beeping every second
Beeping twice per second
Beep Continuously
yes
USB
SNMP
AS400 / Relay contacts
0-40°C; 32-104°F
20-90% non-condensing
0 .. 5000m
if operating above 1000m it is important to reduce load
< 57dBA
101kg
27kg
4U x 19“ x 570mm incl. terminals
2 x 2U x 19“ x 515mm (570mm incl. terminals)
33
Power Supplies
QUASAR II
QUASAR
II
NEU / NEW
Online double-conversion 10, 15, 20, 25, 30kVA
Features
As one of the first UPS on the market, QUASAR
II from EFFEKTA® can be programmed on every
‧ UPS-classification VFI-SS-111 in accordance with
IEC 62040-3
‧ Online double-conversion with sine-wave output
‧ IGBT-rectifier
‧ Comfortable front control panel incl. EPO
‧ Interface for EPO remote control
‧ Space-saving cable feeding from the bottom of the
housing
‧ Small dimensions
(all models 910 x 390 x 900 mm)
‧ Expandable autonomy time
‧ 24 months‘ warranty
required phase configuration via software:
Selective:
1-phase input and 1-phase output
1-phase input and 3-phase output
3-phase input and 1-phase output
3-phase input and 3-phase output
Particularly, the configuration of 1-phase input and
3-phase output is unique on the UPS market.
The usage of IGBT-rectifiers reduces the distortion of
the connected mains. The current consumption is almost
ideal sinus and the power factor is increased compared
with traditional thyristor designed UPS.
Considerable and comfortable extension possibilities
simplify the dimensioning and professional involvement
of the installation in any environment. Amongst others,
several systems can be switched in parallel, to increase
the reliability through redundant operation.
34
Options:
‧ Parallel configuration
‧ Power extension
‧ Output isolating transformer
‧ Slot for optional adapter: relay-card or SNMP
AC large UPS 6-300kVA
block diagram:
1. IGBT power input
2. Battery
3. Inverter power IGBT
4. Static Switch
5. Manual Bypass
Control panel:
Quasar II has a clear control
panel, in which the EPO switch is
already integrated.
Specifications
Specifications
Model
Power
Efficiency (AC-AC) - % (ECO-mode)
Efficiency (AC-AC) - % (Online-mode)
Input
Voltage nominal
Voltage tolerance
Frequency
Power Factor
Output
Voltage
Frequency
Voltage form
Distortion
Crest factor
Batteries
Type
Capacity
Autonomy
Voltage nominal
Min. discharge voltage
Charging voltage
Charging time
Transfertime
AC-DC to bypass
Display
LCD
LED
Acoustic
Restable
alarm
Interface
RS-232 Interface
SNMP (optional)
Relay contacts (optional)
Environment
Temperature
Humidity
Audible noise @ 1m distance)
Weight
Without batteries
Incl. batteries
Dimensions
HxWxD in mm
Safety
Enclosure
Colour
QAUASAR II
10kVA
10kVA / 8kW
QUASAR II
15kVA
15kVA / 12kW
QUASAR II
QUASAR II
QUASAR II
20kVA
25kVA
30kVA
20kVA / 16kW
25kVA / 20kW
30kVA / 24kW
> 98%
> 93% (@ 75% load)
Programmable on 3- or 1-phase: 3-ph. 380VAC / 1-ph. 230VAC
380-415VAC ± 10VAC
50Hz / 60Hz adjustable
0.8
Programmable on 3- or 1-phase: 3-ph. 380/400/415VAC / 1-ph. 220/230/240VAC
50/60Hz ± 0.005Hz (battery mode) ± 1Hz synchronized (line mode)
Sinus-wave
< 3% (linear load), 5% (nonlinear load), in accordance with IEC 62040-3
3:1
Maintenance free sealed lead-acid battery
Internal 60 x 5Ah, 7Ah or 9Ah
10 minutes by nominal load / expandable
720VDC
600VDC
810VDC
7-8h at 90% of total capacity after complete discharge
<1ms
Alphanumeric display
Normal operation / alarm
Yes
Yes
Powermanagement via optional SNMP-Adapter and Webbrowser
4 signals via additional expansion card
0-40°C (battery 20- +30°C)
< 90% non condensing
< 58dBA
60kg
60kg
65kg
65kg
65kg
230kg
230kg
230kg
230kg
230kg
910 x 390 x 900
910 x 390 x 900
910 x 390 x 900
910 x 390 x 900
910 x 390 x 900
EN 50091-2, CEI-EN 62040-1-1, CEI EN 62040-1-2, CEI EN 62040-2, CEI EN 62040-3, CE
IP20
anthracite RAL 7016
35
Power Supplies
Quasar 60-120 60-120
Quasar
Online double-conversion, 60-120kVA, with 3-phase
input, 3-phase output
The UPS Quasar 60-120kVA is a progressive
development of UPS Quasar 10-40kVA version.
The Quasar enables a reliable and uninterruptible power
line. It is a double-conversion unit for supersensitive
industrial and IT applications current available.
Up to 6 systems can be connected in parallel for
redundant operations (n+1operation) or for power
increase.
36
‧ UPS-classification VFI-SS-111 in accordance
with IEC 62040-3
‧ Online double-conversion
‧ Input power factor 0.95
‧ Sine wave current consumption
‧ 100% asymmetric load (>10s)
‧ 2 separate infeeds
‧ Wide input voltage range
‧ ”Power save” mode
‧ Automatic and manual bypass
‧ Modular battery extension
‧ Menu-controlled LCD display
‧ Fully front-operable
‧ RS-232, communication and SNMP via adapter
‧ 24 months’ warranty
‧ N+1 redundancy (optional)
AC large UPS 6-300kVA
Specifications
Specifications
Power (in kVA)
60
80
100
120
Autonomy time in min.
(more info on request)
10
14
20
35
5
9
13
25
5
9
16
25
5
9
16
27
Type
Power
Power in kVA/kW
Input power factor cos phi
Input
Voltage
Frequency
Input power factor correction
Output
Voltage
Current in ampere
Regulation - static
Regulation - dynamic (100% laod fluctuation)
Overload inverter
Overload static bypass
Frequency
Synchronisation-range
Waveform
Crestfactor
Harmonic distortion
Fault reaction
Efficiency (battery full / 100% load)
Batteries
Max. charging current in ampere (adjustable)
Nominal voltage
Number of 12V blocks
Capacity of each block
Type
Expected lifetime
Recharging time
Bypass (EUE)
Nominal voltage
Overload capacity
Manual bypass (standard)
Interface communication
Display
Acoustic alert
Interface
SNMP
Certificates & tests
EMC
Standards
Mechanics / environment
Enclosure
UPS dimension (H x W x D in mm)
Battery pack dimensions (H x W x D in mm)
Weight in kg (UPS without batteries)
Ambient temperature
Rel. air humidity
Audible noise at 1m distance
UPS dimensions
(H x W x D in mm)
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
1800x700x740
battery cabinet dimensions
(H x W x D in mm)
1220x770x950
1220x770x950
1800x911x800
1800x1211x800
1220x770x950
1220x770x950
1800x911x800
1800x1211x800
1220x770x950
1220x770x950
1800x1211x800
1800x2411x800
1800x911x800
1800x911x800
1800x1211x800
1800x1811x800
Q060
Q080
60/48
80/64
0.95
Weight in kg
300+915
300+980
300+1192
300+1741
335+915
335+980
335+1171
335+1713
365+980
365+1171
365+1713
365+2654
455+1466
455+1466
455+2143
455+3069
Q100
Q120
100/80
120/96
3 x 380/400/415VAC (300÷480VAC)
50/60Hz (40÷70Hz)
Yes
87
>92%
32
384VDC
32
115
3 x 380/400/415VAC
144
< 1%
< 6%
125% for 10 minutes / 150% for 10 seconds
150% für 30 minutes / 1000% für 0.1 seconds
50/60Hz (± 0.005% in backup mode)
± 1% to ± 4% selectable
Sine wave
3:1
<3% with linear load
Auto bypass mode / switch-off in case of overload, over-temp., short circuit
>92.5%
>93%
32
384VDC
32
65-200Ah
VRLA
10 years
8 hours 80% capacity
32
384VDC
32
174
>93.8%
40
480VDC
40
380/400/415V
10 x Inom 100msec/ 1.5 x Inom 30min
Yes
LCD display with 21 alphanumeric / status messages
Yes
RS232 / relay contacts for 4 condition information
Optional via software and adapter
CE
EN50091-2, class A, IEC801-2, IEC801-3, IEC801-4
IEC 146-4, EN50091-1, IEC 950
Tower / Protection IP 20 (IEC529, IEC944)
1800x700x740
Depends on battery capacity
400
470
500
540
0-40°C (UPS without battery)
<95% non-condensing
<60dB(A) (depends on load and temperature)
<65dB(A) (depends on load and temperature)
37
Power Supplies
Pegasus 10-40kVA 10-40kVA
Pegasus
10-20 kVA 3/1-phase
10-40 kVA 3/3-phase
Online double-conversion 10, 15, 20, 30, 40kVA
The PEGASUS is a online double-conversion UPS
system with 1- or 3-phase output. It can be configured
parallel-redundant. Up to 6 Systems can be connected
in parallel for redundant operations and increases the
availability.
The electronic components are up to highest standards
as known from military requirements. So you find an
UPS system with enhanced reliability, availability and
safety.
The PEGASUS 10-40kVA is an UPS system with
modular design. Each power module offers complete
self-diagnosis to simplify the “on field” trouble-shooting.
The usage of IGBT rectifiers reduces the distortion
of dependened mains. The current drain is almost
ideal sinus and the power factor was increased in
comparance to traditional thyristor design.
‧ UPS classification VFI-SS111 in accordance with
IEC 62040-3
‧ Online double-conversion
‧ IGBT rectifier
‧ Input power factor >0,99
‧ Modular technology
‧ Models with 1- or 3 phase output available
‧ Modules with progressive self diagnostics
‧ High efficiency
‧ Output sine wave
‧ Digital control
‧ Comfortable LCD display
‧ Compact design
‧ Low weight
‧ RS-232 (equipped as standard)
‧ Additional slot for optional relaycard, RS485or SNMP-adapter
‧ 24 months’ warranty
‧ Optionally incl. BACS battery management
‧ Optionally up to 6 devices parallel
‧ Optionally external battery extension
38
AC large UPS 6-300kVA
block diagram
UPS electronics (modular
design / power module)
control panel
Specifications
Specifications
Model
Power
Efficiency % (ECO-Mode)
Efficiency (AC-AC) - % (Online-Mode)
Input
Voltage nominal
Voltage tolerance
Frequency
Power factor
Output
Voltage
Frequency
Waveform
Distortion
Crest factor
Batteries
Type
Capacity
Autonomy
Voltage nominal
Charging voltage
Recharging time
Transfertime
AC-DC to bypass
Display
LCD
LED
Acoustic alarm Restable
Interface
RS-232 interface
SNMP (Option)
Relay contacts (optionally)
Environment
Temperature
Humidity
Audible noise (1m distance)
Weight
Without batteries
With batteries
Dimensions
HxWxD in mm
Safety
Enclosure
Colour
PEGASUS 10kVA
31/33
10kVA / 8kW
>98
>92
PEGASUS 15kVA
31/33
15kVA / 12kW
>98
>92
PEGASUS 20kVA
PEGASUS 30KVA
PEGASUS 40kVA
31/33
33
33
20kVA / 16kW
30kVA / 24kW
40kVA / 32kW
>98
>98
>98
>92
>92
>92
3-ph. 400VAC
380-400-415VAC +10% / -20%
50Hz – 60Hz +/- 5Hz
>0.99
31ph model: 220, 230, 240 selectable / 33ph model: 380-4 5VAC selectable
50Hz or 60Hz +/- 0.001Hz (battery mode) +/- 2Hz synchronised (line mode)
Sinus
< 1% (linear load), 5% (nonlinear load), in accordance with IEC 62040-3
3:1
maintenance free lead acid batteries
on request
on request
on request
on request
on request
on request
on request
on request
on request
on request
2 x 360VDC @ 25°C
on request
on request
on request
on request
on request
7-8h 90% capacity
0ms
Alphanumeric backlit display
Diagramm with LEDs
Yes
Yes
Powermanagement via optional SNMP-Adapter and Webbrowser
Eight Signals via additional expansion card
0-40°C (Battery 0 - +25°C)
20-80% non condensing
< 50dBA
90kgs
100kgs
100kgs
141kgs
141kgs
250kgs
260kgs
260kgs
on request
on request
1200 x 450 x 650
1200 x 450 x 650
1200 x 450 x 650
1200 x 450 x 650
1200 x 450 x 650
EN 50091-2, CE
IP 20
RAL 7035
39
Power Supplies
Pegasus 60-160kVA 60-160kVA
Pegasus
60, 80, 100, 125, 160kVA 3/3 phase
The output isolation transformer of the PEGASUS UPS
provides the galvanic isolation between consumer load
and DC intermediate circuit and battery.
‧ UPS classification VFI-SS111 in accordance
with IEC 62040-3
‧ Online double-conversion
‧ IGBT rectifier
‧ Output isolation transformer
‧ Power factor >0,99
‧ Output sine wave
‧ Digital control
‧ Comfortable LCD display
‧ Compact design
‧ RS-232 (equipped as standard)
‧ Additional slot for optional relaycard, RS485or SNMP-adapter
‧ 24 months’ warranty
The electronic components are up to highest standards
as known from military requirements. So you find an UPS
system with enhanced reliability, availability and safety.
‧ Optionally incl. BACS battery management
‧ Optionally up to 6 devices parallel
‧ Optionally external battery extension
Online double-conversion 60, 80, 100, 125, 160kVA
The PEGASUS is a online double-conversion UPS system
with 3-phase output. It can be configured parallel-redundant
and increases the availability of the power source.
The usage of IGBT rectifiers reduces the distortion of
dependent mains. The current drain is almost ideal sinus
and the power factor was increased in comparison to
traditional thyristor design.
40
AC large UPS 6-300kVA
block diagram
control panel
Specifications
Specifications
Model
Power
Efficiency (AC-AC) - % (ECO mode)
Efficiency (AC-AC) - % (Online mode)
Input
Voltage nominal
Voltage tolerance
Frequency
Power factor (@ 400V)
Output
Voltage
Frequency
Waveform
Output current nominal @ CosPhi 0.8/1.0
Short-circuit current
Distortion
Crest factor
Batteries
Type
Capacity
Cells
Autonomy
Nominal voltage
Minimal discharging voltage
Charging voltage
Recharging time
Transfer time
AC-DC to bypass
Display
LCD
LED
Acoustic alarm Resettable
Interface
RS-232 Interface
SNMP
Relay contacts
Environment
Temperature
Humidity
Audible noise
(@ 1m distance)
Weight
Without batteries
Dimensions
HxWxD in mm
Safety
Enclosure
Color
PEGASUS
60kVA
60kVA / 48kW
80/70A
140A
PEGASUS
PEGASUS
PEGASUS
100kVA
125kVA
160kVA
100kVA / 80kW
125kVA / 100kW
160kVA / 128kW
>98
>93
3-ph. 400VAC
380-400-415VAC +10% / -20%
50Hz – 60Hz +/- 5Hz
>0.99
380-415VAC +/- 1% adjustable
50Hz or 60Hz +/- 0,001Hz (battery mode) +/- 2Hz synchronized (line mode)
Sinus
116/93A
145/116A
180/145A
232/186A
186A
232A
290A
372A
<2% (linear load), <5% (nonlinear load), in accordance to IEC 62040-3
3:1
Maintenance free lead acid batteries
On request
300
On request
600VDC @ 25°C
496VDC
On request
7-8h 90% capacity
0ms
Alphanumeric backlit display
Diagram with LEDs
Yes
Yes
Power management via optional SNMP adapter and web browser
optionally via additional expansion card
0-40°C (batteries 0- +25°C)
<95% no condensing
< 60dBA
570kg
1670 x 815 x 825
PEGASUS
80kVA
80kVA / 64kW
600kg
1670 x 815 x 825
630kg
1670 x 815 x 825
EN 50091-2, CE
IP 20
RAL 7035
662kg
1670 x 815 x 825
720kg
1670 x 815 x 825
41
Power Supplies
Pegasus 200-300kVA 200-300kVA
Pegasus
200-300 kVA 3/3-phase
Online double-conversion 200, 250, 300kVA
The PEGASUS is a online double-conversion UPS
system with 3-phase output. It can be configured
parallel-redundant and increases the availability of the
power source.
The electronic components are up to highest standards
as known from military requirements.So you find an
UPS system with enhanced reliability, availability and
safety.
The usage of IGBT rectifiers reduces the distortion
of dependened mains. The current drain is almost
ideal sinus and the power factor was increased in
comparance to traditional thyristor design.
The output isolation transformer of the PEGASUS UPS
provides the galvanic isolation between consumer load
and DC intermediate circuit and battery.
42
‧ UPS classification VFI-SS111 in accordance
with IEC 62040-3
‧ Online double-conversion
‧ IGBT rectifier
‧ output isolation transformer
‧ Input power factor >0.96
‧ Output sine wave
‧ Digital control
‧ Comfortable LCD display
‧ Compact design
‧ RS-232 (equipped as standard)
‧ Additional slot for optional relaycard, RS485or SNMP-adapter
‧ 24 months’ warranty
‧ Optionally incl. BACS battery management
‧ Optionally up to 6 devices parallel
‧ Optionally external battery extension
AC large UPS 6-300kVA
block diagram
control panel
UPS electronics
Specifications
Specifications
Model
Power
Efficiency (AC-AC) - % (ECO mode)
Efficiency (AC-AC) - % (Online mode)
Input
Voltage nominal
Voltage tolerance
Frequency
Power factor (@ 400V)
Output
Voltage
Frequency
waveform
Output current nominal @ CosPhi 0.8/1.0
Short-circuit current
Distortion
Crest factor
Batteries
Type
Capacity
Cells
Autonomy
Nominal voltage
Minimal discharging voltage
Charging voltage
Recharging time
Transfer time
AC-DC to bypass
Display
LCD
LED
Acoustic alarm
Resetable
Interface
RS-232 Interface
SNMP (Option)
Relay contacts
Environmentz
Temperature
Humidity
Audible noise (@ 1m distance)
Weight
Without batteries
Dimensions
HxWxD in mm
Safety
Enclosure
Colour
PEGASUS 200kVA
200kVA / 160kW
>97
>93
PEGASUS 250kVA
PEGASUS 300kVA
250kVA / 200kW
300kVA / 240kW
>97
>97
>93
>93
3-ph. 400VAC
380-400-415VAC +10% / -20%
50Hz – 60Hz +/- 5Hz
>0.96
380-415VAC +/- 1% einstellbar
50Hz or 60Hz +/- 0.001Hz (battery mode) +/- 2Hz synchronised (line mode)
Sinus
290/230A
360/290A
430/360A
462A
520A
578A
<2% (linear load), <5% (nonlinear load), in accordance to IEC 62040-3
3:1
Maintenance free lead acid batteries
On request
On request
On request
300
300
300
On request
On request
On request
600VDC bei 25°C
496VDC
On request
On request
On request
7-8h 90% capacity
0ms
Alphanumeric backlit display
Diagram with LEDs
Yes
Yes
Powermanagement via optional SNMP adapter and webbrowser
Via additional expansion card
0-40°C (batteries 0- +25°C)
<95% noncondensing
< 62dBA
870kgs
1020kgs
1200kgs
1900 x 1200 x 860
1900 x 1200 x 860
1900 x 1200 x 860
EN 50091-2, CE
IP 20
RAL 7035
43
Power Supplies
MHD ModularModular
MHD
Online double-conversion 4-24kVA
MHD Modular is a scalable single phase or three-phase
double-conversion UPS and can be configured to a
capacity of 4kVA, 8kVA, 12kVA, 16kVA, 20kVA, 24kVA
with maximum 6 modules. It can be configured to
parallel redundancy which provides the maximum
reliability. And delivers power output per modules from
4kVA to 24 kVA.
The MHD Modular is scalable in the capacity between
4-24kVA as well as scalable in autonomy time with
additional external battery cabinetts, or it can be
configured for a N+X parallel redundancy as well..
Each UPS system includes maximum six UPS modules
that each module is operating independetly. If any
one UPS module fails, the load is instantaneously
redistributed among the remaining modules and the
defective UPS module is automatically taken off-line
from the system. Maintenance personnel can easily
change the defective module during normal operation
without disturbing the reliability.
44
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
UPS-classification VFI-SS-111 (IEC 62040-3)
Online double-conversion
Modular design
Scalable capacity in 4kVA steps up to 24kVA
1- or 3-phase input
Hot swappable modules
Sinewave output
Digital signalprocessor
Clearly arranged LCD display
Modular battery extension
Optionally incl. BACS battery management
Compact design
Little weight
RS232, RS485 and expansion slots for
different communication ports (SNMP, Relais)
‧ 24 months’ warranty
Casing variation with additional space
for isolation transformator or other
AC large modular UPS 4-120kVA
The 4kVA-modules of EFFEKTA® MHD Modular
provide advanced UPS technology with high operating
efficiency. The System absolutely prevents power
failures, power sags, surges, brownouts, line noise,
spikes, frequency variations switching transients and
harmonic distortion.
With its fast DSP-controller (Digital Signal Processing) it
offers a highend sinewave-quality and high performance
in controlling input & output.
The display of MHD Modular shows all important
UPS informations in a userfriendly way. The backlight
improves the readability. All important messages
concerning the configuration and diagnosis as well as
controlls and management of the UPS can be seen at a
glance.
You can watch all data like input and output voltage,
frequency, connection data, position and and actual
state of the modules. The facility of inspection is
provided by additional LEDs for informations about most
impoertant state of operation like „normal“, „on battery“,
„bypass“ and „fault“.
Also the MHD Modular provides communication ports
for remote monitoring via EDP. Standard are a RS232
and RS485 port at ther rear of the UPS. Additionally
the intelligent slot provides more options for EDP or
other monitoring functions for your UPS management.
Amongst others SNMP-/WEB adapters or relais cards
could be used.
45
Power Supplies
MHD ModularModular
MHD
LOAD
LOAD
The MHD Modular is a scalable online double-conversion
UPS and with up to 6 modules it can be configured to
4kVA, 8kVA, 12kVA, 16kVA, 20kVA and 24kVA.
One of the most important advantages of the
modularand redundant design is the improved safety
and reliability. If the MHD Modular is configured to
N+X parallel- redundancy, the load is instantaneously
redistributed among the remaining modules. Because
each module is a seperately operating device, there is
no central control system that could be damaged, so this
also increases the safety.
The MHD Modular has got hardwired outputs with one
phase and can be used with one or three phase inputs
alternatively. In case of operating with three phases,
each of them is monitored by the UPS.
46
Additional modules can be installed to the MHD Modular
during normal operation without much time and effort.
This hot swappable methode provides subsequent
extension of the UPS system without any disturbance of
normal operation of the users, so this
system provides safing of costs. Also the possibility
to change defective modules during normal operation
without any disturbance of the users leads to more
safing of costs.
AC large modular UPS 4-120kVA
Specifications
Specifications
Number of modulescapacity
1
Module
2
Modules
3
Modules
4
Modules
5
Modules
6
Modules
N
N+1 (4kVA)
N+2 (8kVA)
N+3 (12kVA)
N+4 (16kVA)
N+5 (20kVA)
N
N+1 (4kVA)
N+2 (8kVA)
N+3 (12kVA)
N+4 (16kVA)
N
N+1 (4kVA)
N+2 (8kVA)
N+3 (12kVA)
N
N+1 (4kVA)
N+2 (8kVA)
N
N+1 (4kVA)
4kVA
8kVA
12kVA
16kVA
20kVA
24kVA
Model
Capcity
Input
Output
N
Singel / three phase
Wiring
Voltage
Input frequency
Power factor
Bypass
Phase
Wiring
Voltage
Power factor
Output frequency
MHD Modular
4~24kVA
Single phase
1Ф2W + G
160~300VAC
140~300VAC
118~300VAC
70% load
50-70% load
50% load
Three phase
3Ф4W + G
277~520VAC
242~520VAC
204~520VAC
50/60 (1±8%) Hz
0,98
80~264VAC
140~457VAC
Single phase
1Ф2W + G
230 (±2%) VAC
0,7
Same as input frequency
50/60 (1±0,5%) Hz (backup mode)
110-130%, after 30 seconds transfer to bypass
>130%, after 2 seconds transfer to bypass
Overload
Capacity / module
Output capacity
External batteries
Connect to generator
Communication / interface
Weight
Module
Cabinet
Dimensions of modules HxWxD in mm
Dimensions of cabinet HxWxD in mm
4kVA
4kVA x number of modules
120VDC (10 batteries in each cabinet)
Yes
RS232, RS485, intelligent slot
15kg
75kg
88x430x530
965x442x700
Battery capacity / autonomy time
Capacity VA
4000
4000
4000
4000
8000
8000
8000
8000
Capacity
watt
2800
2800
2800
2800
5600
5600
5600
5600
Number of
modules
1
1
1
1
2
2
2
2
Autonomy
minutes
30
40
60
90
10
25
30
45
Battery configuration
120V-28Ah
120V-45Ah
2x120V-28Ah
120V-65Ah
120V-28Ah
120V-45Ah
2x120V-28Ah
3x120V-28Ah
Capacity VA
12000
12000
12000
16000
16000
16000
20000
20000
24000
24000
Capacity
watt
8400
8400
8400
11200
11200
11200
14000
14000
16800
16800
Number of
modules
3
3
3
4
4
4
5
5
6
6
Autonomy
minutes
15
20
30
10
15
20
15
25
10
20
Battery configuration
2x120V-28Ah
120V-65Ah
3x120V-28Ah
2x120V-28Ah
120V-65Ah
3x120V-28Ah
3x120V-28Ah
2x120V-65Ah
3x120V-28Ah
2x120V-65Ah
47
Power Supplies
MHD ModularModular
P3
MHD
P3
NEU / NEW
Features
Online double-conversion
15, 30, 45, 60, 75, 90, 105, 120kVA
with 3-phase input and output, n+X redundancy
EFFEKTA®s‘ MHD Modular P3 covers the area of
redundant systems with 3-phase connection from up to
120kVA.
It can accommodate up to 8 15kVA UPS-modules, which
could be exchanged or added during a continuously
operation („Hot-Swappable“). In case of failure or
removal of a module, the load redistribute automatically
and without interruption to the remaining modules.
All settings, such as module number and parallel
redundancy can be performed comfortably over the
control panel with LCD display.
48
‧ UPS-classification VFI-SS-111 in accordance with
IEC 62040-3
‧ Online double-conversion with sinus output
‧ Modular design for up to 8 UPS-modules
‧ Up to 99,99% availability through n+X redundancy
‧ All modules „Hot-Swappable“
‧ Allmost sine-wave current consumption and high
efficiency
‧ Suitable for generator operation
‧ Clear front control panel incl. multilingual LCD-Display
‧ Interface for EPO remote control
‧ Expandable autonomy time
‧ 24 months‘ warranty
Options:
‧ Front operable Power-Distribution-Panel
‧ External battery cabinet
‧ Output isolating transformer
‧ Slot for optional communication adapter
AC large modular UPS 4-120kVA
UPS and battery status, parameters and warnings are
shown on the control panel with LCD-display. Ater start-up
of the UPS, all operations could be done over the control
panel.
With N+S-redundancy, the MHD Modular P3 offers the
most reliable power supply configuraion.
N = Minimum number of required modules for the total
load on the UPS.
X = Number of redundant modules of the UPS.
Specifications
Specifications
Power system
Power modul
Efficiency (AC-AC) - % (Online-mode)
Input
Voltage nominal
Voltage tolerance
Frequency
Power Factor
Output
Voltage
Frequency
Voltage form
Distortion
Crest factor
Batteries
Type
Capacity
Autonomy
Voltage nominal
Min. discharge voltage
Charging voltage
Charging time
Transfertime
AC-DC to bypass
Display
LCD
LED
Acoustic
Restable
alarm
Interface
RS-232 Interface
SNMP (optional)
Relay contacts (optional)
Environment
Temperature
Humidity
Audible noise
Weight
Cabinet
Modul
Dimensons
Cabinet HxWxD in mm
Modul HxWxD in mm
Enclosure
Safety
Colour
15-120kVA (maximum 8 modules in parallel configuration)
15kVA / 12kW
> 90%
400VAC 3 phase + neutral conductor + ground / wye connection
204 ~ 520VAC 100% linear o. non linear load
50Hz / 60Hz adjustable
0.99
380 / 400VAC
50/60Hz ± 0.05Hz (battery mode) ± 1Hz synchronised (line mode)
Sinus wave
< 3% (linear load), 5% (non linear load), in accordance with IEC 62040-3
3:1
Maintenance free sealed lead-acid battery
Configuration dependent
10 minutes by nominal load / expandable
480VDC
400VDC
548VDC ± 1%
7-8h at 90% of total capacity after complete discharge
< 1ms
Alphanumeric display
Normal operation / battery / bypass / failure
Yes
RS232, RS485, IntelligentSlot
Powermanagement via optional SNMP-Adapter and Webbrowser
4 signals via additional expansion card
0-40°C (storage -25°C - 55°C)
20-90% non condensing
< 62dBA
250kg
35kg
2000 x 600 x 1000
131 x 700 x 440
CE
EMI: IEC/EN 62040-2 / EMS: IEC/EN 61000-4-2/3/4/5/6/8 / IEC/EN 61000-2-2
IP 20
black
49
Power Supplies
Software
Software
for all EFFEKTA® AC UPSs (400VA-300kVA)
The UPS management software solution PowerShut Plus
runs as a client/server application for heterogeneous
networks or local computers. It works on Windows
95/98/2000/NT/XP/Vista (Business and higher), Novell,
Linux and all current Unix derivatives. It also includes an
SNMP agent for Windows NT and Novell. All Servers on
the network can be shut down via RCCMD (MultiserverShutdown). The software provides all important UPS
information such as battery level, temperature, condition
of line-voltage and others in clear graphical displays.
Disruptions can be reported by e-mail, mobile phone or fax.
50
‧ Available for Windows 9x, NT, 2K, 2003 Server, XP,
Vista (Business and higher), Netware, Macintosh,
UNIX and VMS
‧ UPS monitoring via floating contacts or serial interface
‧ Local or network shutdown on up to several
hundred computers
‧ Integrated SNMP subagent (RFC 1628)
‧ Graphical interface with all UPS information
‧ Graphical interface on UNIX, MAC, VMS (JAVAMON)
‧ Event-based dispatch of network messages
‧ Event-based dispatch of e-mails and SMS
‧ Logging of all UPS status information and
measurements in MS-Excel file
‧ Schedulers for time-controlled execution of
reboot, shutdown etc.
UPS management
Line fail
UPSMON module (right-hand images)
. Monitoring of all UPSs connected
via UPSMAN/SNMP adapter
. Remote network control of all UPS
. Graphical representation of UPS input
data (current, voltage)
. Reading and display UPSMAN event log files
. Programming UPSMAN scheduler
. Graphical interface with all UPS information
. Graphical interface on UNIX, MAC, VMS
(JAVAMON)
Normal operation
UPSMAN
configuration
UPSMAN module (right-hand images)
. UPS monitoring via with floating contacts or serially
. Local or network shutdown
. Integrated SNMP subagent (RFC 1628)
. Event-based dispatch of network messages
. Event-based dispatch of e-mails and SMS
. Logging of all UPS status information and
measurement data
. Scheduler for time-controlled execution of
Message:
“line fail“
reboot, shutdown etc.
. Password protection for all UPS remote functions
. Time dependent control of up to four
.
.
consumer units (optional hardware necessary)
Configuration parameters identical on all platforms
(UNIX, Windows, Netware, VMS, MAC)
UPSMAN runs in the background as an independent
service process
RCCMD (optional client module / bottom left image)
Available for Windows 9x, NT, 2000, XP,
Vista (Business and higher) Netware,
Mac OS (up to 9.x), UNIX and VMS
Currently for 25 operating systems, older
ones also available
Unlimited number of clients possible
Sequential network shutdown configurable
Configuration of clients on network
Event-based connection with UPSMAN
Simple installation and configuration
Protected against unauthorised client regulation
No network load at all
.
.
.
.
.
.
.
.
.
51
Power Supplies
SNMP
SNMP
for all EFFEKTA® AC UPSs (400VA-300kVA)
CS 121 SNMP adapter
. Powerful 32-bit RISC processor, 8MB RAM,
4MB Flash
The CS121 is equipped with a 32-bit processor, 8 MB
RAM, 4 MB Flash, 2 serial interfaces and a 10/100MBIT
network connection.
COM1 is provided for communication with the UPS,
COM2 may be used for configuring the adapter,
connection to a modem or to forwarding UPS data to
other computers.
Other features in the area of UPS visualisation and the
remote-controlled network shutdown option (RCCMD)
make the CS121 easy to operate and increase its range
of application.
Optionally the CS121 "Budget" (right hand picture) is
available for reasonable network solutions. This version
of the adapter is for the limited purpose of network
communication, so it is not equipped with the additional
interfaces of the "Professional" version (picture at the
top of the page).
52
. Supported protocols: SNMP, HTTP, Telnet,
.
.
.
.
.
.
UPSMON, PPP/ SLIP, SMTP and FTP, Modbus
10/100 Mbit Ethernet connection
2 serial RS-232 interfaces (RS-422/ 485 optional)
Modem support for UPS dialer and
internet connection
Integrated WEB server
Visualisation via UPSMON, JAVAMON, UNMS,
NMS,WEB browser or TELNET
Support UPS standard MIB RFC1628
UPS management
Configuration and monitoring via web browser
UNMS (9 UPSs)
UPSMAN module
UNMS UPS monitoring panel (freeware)
Available for Windows 95/ 98/ ME/ NT/ 2000 / XP /
Vista (Business and higher)
Clear representation of all network UPS
Up to 9 UPS in network can be monitored
(freeware version)
Simple configuration
Number of connections adjustable
Acoustic alert
Expandable on request
SNMP adapter support
Up to 1500 nodes optional
. UPS monitoring via floating contacts
.
.
.
.
.
.
.
or serial interface
Local or network shutdown
Event-based dispatch of network messages
Event-based dispatch of e-mails and SMS
Schedulers for time-controlled execution of
reboot, shutdown etc.
Password protection for all UPS remote-functions
Configuration via common web browsers
Monitoring via UPSMON possible
.
.
.
.
.
.
.
.
USW (”UPS SNMP Watch”, left hand image)
Monitoring of parallel and single UPSs
Clear representation of all UPS status information
User-defined configuration of all events
Sequential network shutdown of computers in
homogeneous and heterogeneous networks
Available for UNIX and Windows NT/ 2000 / XP /
Vista (Business and higher)
UPS control via SNMP adapter and SNMP
software agent (UPSMAN)
Further graphical interfaces started via
mouse-click (UPSMON, JAVAMON)
Java-based program
.
.
.
.
.
.
.
.
53
Power Supplies
External bypass
External
bypass
An external bypass can be used to guarantee optimum
availability of the EFFEKTA®’ UPS systems, particulary
for critical applications. During UPS maintenance, the
bypass bridge the UPS and provides the load with
uninterrupted power after a manual changeover.
Type
Adaptable up to (UPS power in kVA)
Socket
Mounting/construction
Type
Adaptable up to (UPS power in kVA)
Socket
Mounting/construction
Further models on request.
54
Type
Adaptable up to (UPS power in kVA)
Socket
Mounting/construction
Z00/Byp016A-000
3kVA
Single-phase hardwired
Wall-mounting
Type
Adaptable up to (UPS power in kVA)
Socket
Mounting/construction
ZRO/Bypk40A-000
6kVA
Single-phase hardwired
19“ rack, 2U
Type
Adaptable up to (UPS power in kVA)
Socket
Mounting/construction
Z00/Byp100A-000
40kVA
Three-phase hardwired
Wall-mounting
Z00/Byp016A-A02
3kVA
Single-phase pluggable
19“ rack, 2U
Z00/Byp063A-000
30kVA
Three-phase hardwired
Optionally one-phase hardwired
Wall-mounting
UPS accessories
Battery cabinets cabinets
Battery
B10
Battery cabinet for UPSs in office premises
Steel cabinet with synthetic front (IP 20)
Article
B10/…
B10/…
Dimensions
(H x W x D in mm)
207x140x437
207x140x437
Adapted
battery type
BFR/BT12-7
BFR/BT12-9.5
Max. number of
batteries
8
8
B28
Battery cabinet for small and medium UPS types.
Lacquered steel construction (black / IP20) on casters.
Optionally with BACS incl. LCD Display.
Article
B28
Dimensions
(H x W x D in mm)
445 x 285 x 520
B28 BACS
445 x 285 x 520
Adapted
battery type
BT 12-28
(12V / 28Ah)
BT 12-28
(12V / 28Ah)
Max. number of
batteries
8
8
B30
Battery cabinet for large UPSs or high autonomy times
Powder-coated steel construction (IP 20)
Article
B30/S600-3
B30/S600-4
B30/S800-3
B30/S800-4
B30/S800-4
Dimensions
(H x W x D in mm)
1220x580x950
1220x580x950
1220x770x950
1220x770x950
1220x770x950
Adapted
battery type
BZR/BTL12-33
BZR/BTL12-45
BZR/BTL12-55
BZR/BTL12-65
BZR/BTL12-80
Max. number of
batteries
32
32
32
32
32
B40
Battery cabinet for large UPSs or high autonomy times
Powder-coated steel construction (IP 20)
Article
B40/…
B40/…
B40/…
B40/…
Dimensions
(H x W x D in mm)
on request
on request
on request
on request
Adapted
battery type
BZR/BTL12-100
BZR/BTL12-120
BZR/BTL12-150
BZR/BTL12-200
Max. number of
batteries
on request
on request
on request
on request
55
Power Supplies
BT batteries
BT
batteries
BT 12-28
BT 12-18
Our long-standing experience with emergency power
systems and uninterruptible power supply units is
our guarantee for the highest quality and reliability of
EFFEKTA® batteries.
BT batteries are ideally suited for use in:
. Uninterruptible power supplies (UPSs)
. Telecommunications systems
. Fire alarm and safety systems
. Medical equipment
. Photovoltaic applications
Advantage of BT batteries:
. Fully maintenance-free
. High recombination in cycle activity
. Valve-regulated plastic container as overload protection
. Excellent high-current capability
. Classified as non-dangerous in accordance with IATA
. Cycle-resistant (more than 400 recharging/discharging
cycles up to 50% DOD)
. Robust construction
. Location-independent
56
BT 12-0.8
BT 12-5
BT 12-7
VdS certified
Batteries
Specifications
Specifications
Type
Voltage in (V)
Capacity
in Ah (C20)
L (mm)
BT 12-1,2
BT 12-2,3
BT 12-2,8
BT 12-2,9
BT 12-3,2
BT 12-5
BT 12-7E
BT 12-7 (VdS)
BT 12-9
BT 12-9,5
BT 12-12
BT 12-18
BT 12-18i
BT 12-20
BT 12-28
BT 12-28S
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
12
1,2
2,3
2,8
2,9
3,2
5
7
7
9
9,5
12
18
18
20
28
28
97
178
104,5
79,5
134,5
90
151
151
151
151
151
181
181
181
166
166
BT 6-3,2
BT 6-12
6
6
3,2
12
134
151
W (mm)
12V types
43
34,5
47,5
56
67
70
65
65
65
65
98
77
77
77
175
126
6V types
34
50
H (mm)
H (mm)
max.
Weight
in kg
Terminal
standard / optional
52
60,5
69,5
99
59,5
101
95
95
95
95
95
167
167
167
125
174
58
66,5
69,5
105
65,5
107
101
101
101
101
101
167
167
167
125
174
0.6
0.97
1
1.1
1.3
1.7
2.15
2.26
2.4
2.63
3.6
5
5
5.9
8.6
8.6
F1
F1
F2/F1
F1
F1
F1/F2
F2
F2/S-type: F1
F2
F2
F2
F3
F13
F3/F13
F13
F11
60,5
95
66,5
100
0.65
1.8
F1
F1/F2
57
Power Supplies
BTL batteries
BTL
batteries
BTL 12-65
BTL 12-100
Our long-standing experience with emergency power
systems and uninterruptible power supply units is
our guarantee for the highest quality and reliability of
EFFEKTA® batteries.
BTL 12-45
BTL batteries are ideally suited to use in:
‧ Uninterruptible power supplies (UPSs)
‧ Telecommunications systems
‧ Fire alarm and safety systems
‧ Medical equipment
‧ Photovoltaic application
‧ Emergency lighting systems
Advantage of BTL batteries:
‧ Absolutely maintenance-free
‧ High recombination in cycle activity
‧ Valve-regulated plastic container as overload protection
‧ Excellent high-current capability
‧ Classified as non-dangerous in accordance with IATA
‧ Long service life of approx. 10 years
‧ Cycle-resistant (more than 500 recharging/discharging
‧ cycles up to 50% DOD)
‧ Robust construction
‧ Location-independent
58
BTL 12-55
BTL 12-33
Batteries
Specifications
Specifications
Type
Voltage
(V)
in
Capacity
in Ah (C20)
L (mm)
BTL 12-33
BTL 12-45
BTL 12-55
BTL 12-60
BTL 12-65
BTL 12-75
BTL 12-80
BTL 12-90
BTL 12-100
BTL 12-120
BTL 12-120S
BTL 12-150
BTL 12-200
12
12
12
12
12
12
12
12
12
12
12
12
12
33
45
55
60
65
75
80
90
100
120
120
150
200
195
198
229
260
350
260
350
306
320
407
330
483
522
BTL 6-100
6
100
194
W (mm)
12V types
130
166
138
169
167
169
167
169
172
177
171
170
240
6V types
170
H (mm)
H (mm)
max.
Weight
kg
in
Terminal
159
170
210
210
180
210
180
210
220
227
220
240
218
180
170
235
235
183
235
183
217
227
227
227
240
240
10.2
13.2
18
20.5
21
23.5
24
28.5
30
35
32
44.5
60
F11
F11
F11
F11
F11
F11
F11
F12/F5
F12/F5
F12/F5
F12/F5
F12/F5
F12/F5
205
322
16.5
On request
59
Power Supplies
Front terminalterminal
batteries
Front
BTL front terminal batteries from EFFEKTA® have
the same electrical construction as batteries of the
BTL types. However the special dimensions of the
batteries mean that they are compact and easy to
maintain especially in 19’’ rack cabinets.
BFR/BTL12-55F
(left-hand image: terminals)
BFR/BTL12-150F
(right-hand image: terminals)
BFR/BTL12-105F
(right-hand image: terminals)
60
BTL Series type
Voltage in (V)
BTL 12-55F
BTL 12-90F
BTL 12-105F
BTL 12-110F
BTL 12-150F
12
12
12
12
12
Capacity
in Ah (C20)
55
90
105
110
150
L (mm)
W (mm)
H (mm)
277
563
502
394
552
106
114
111
110
110
222
188
236
286
288
H (mm)
max.
222
188
236
286
288
Weight
in kg
18
26.5
32.5
33
45
Terminal
F12
F12
F12
F12
F12
Batteries
Terminals
Terminals
More information on request.
61
Power Supplies
BACS
BACS
BACS, the Battery Analysis & Care System, represents
a groundbreaking innovation in the field of battery
secured power supplies. This patent-pending technology
sets completely new standards in terms of true battery
management. BACS guarantees optimum safety and
capacity of the battery pack throughout its entire life cycle,
thus safeguarding the functionality of your power supplies.
BACS is available as build-in-version as well as external
version for many EFFEKTA®-UPSs. It is also available
on demand for different battery-systems.
General functions of BACS:
BACS
"RTV"-Module
- Automatic adjustment of the battery pack to parent
systems (control circuits enable automatic
harmonisation with the charger)
- Internal resistance, temperature and voltage
measurements enable battery status monitoring and
automatic compensation of key parameters
- The system is equipped with a status display with
alarm output
- Communication via RS232, SNMP or voltage-free
contacts
62
BACS
"RTV"-Module
BACS
"RTV"-Module
Charged to
same level by
"equalizing"
BACS
"Core"-Module
- Uniform battery statuses are guaranteed via a
controlled equalizing process
BACS
"RTV"-Module
(Output for
signals/alarms)
Batteries
BACS can find out each damaged or weak battery
before the whole system gets critical
Integration of BACS technology benefits a complete
system (battery pack) in the following ways:
- Increase in useful life of the batteries and consequently
also the entire battery pack.
- Guarantees maximum possible system capacity at all
times (increase of up to 20%).
- Warnings output in the case of weak or defective
systems, in particular display of the defective battery
block. Important especially in safety-critical areas such
as UPS equipment.
- Alarm if maximum ratings are exceeded (e.g. excessive
battery voltage or temperature).
- Existing UPS equipment can be upgraded at any time
Top image: MHD-display with BACS-messages
- Individual battery blocks can be exchanged (traditional
battery management requires all batteries to be
exchanged).
63
Power Supplies
BACS
BACS
How BACS works and its benefits in comparison to
conventional battery-management-systems:
Traditionally, batteries in all common UPS systems have
been connected and charged in series. The voltage
present at the batteries is monitored. This is normally
approx. 12-13V or a multiple thereof in accordance with
the battery voltage. In this way, it is possible to measure
whether the necessary voltage to supply the required
battery capacity is available. EFFEKTA®’s BACS is
working more accurately:
Fig. 1: In series connected and charged batteries have different capacity because of different conditions. As a result of natural ageing,
these batteries already have different charge statuses after only a
short period of use due to internal chemical processes.
Fig. 2: Standard charging of the batteries using traditional methods
causes overcharging or deep discharging and damage to individual
batteries, which in turn compromises the reliability of the entire
system.
64
The BACS benefits:
1. Each battery is individually monitored via a dedicated
processor-controlled “RTV” module. This also enables
defective batteries on a system to be identified.
This elimiates one important weak spot of conventional
systems: Even defective or discharged batteries can
supply the required 12-13V for a short period, which
often causes the incorrect assumption in battery
management terms that the battery status is OK. This
leads to an excessively rapid discharge in the case of
a power failure. Not so with BACS because weak or
defective batteries are reported on time.
2. The user is informed of defective or weak batteries
BEFORE any potential damage occurs.
In conventional systems the capacity of the battery/
batteries is actually depleted, although the display (LED
chain, LCD display or software) states otherwise. (s.
item 1.) The safety of a UPS system is thus no longer
guaranteed. The necessary autonomous time for a
secure shutdown may not be available, which would
result in the uncontrolled crash of all consumers.
Batteries
200 Ah-batteries with BACS in Quasar batterie cabinett
3. Each battery is individually monitored via a dedicated
processor-controlled “RTV” module. This also enables
defective batteries on a system to be identified. (Each
single battery can be changed instad of the mor expensive exchange of whole battery line)
Traditional battery management systems have following
restriction: In the case of multiple batteries connected
in parallel, only one average voltage value is calculated
per block, which can cause individual defective batteries
amongst intact ones to be overlooked, thus diminishing
the capacity of the entire system.
Detail view of single modules. Detection and exchange of defective
batteries easily possible.
BACS
"RTV"-Module
BACS
"RTV"-Module
BACS
"RTV"-Module
BACS
"RTV"-Module
Charged to
same level by
"equalizing"
BACS
"Core"-Module
(Output for
signals/alarms)
Fig. 3: All batteries attain the same charging level at the end of
the charging process, avoiding overcharging or deep discharging
of individual batteries and optimising overall capacity.
On some battery management systems, voltage measurements can be set to run over a defined long period
with a specified load, but these are of no help in this case.
4. The batteries of a system are charged to the same
level, which increases both the overall capacity and the
life expectancy of the system.
This elimiates another weak spot of conventional systems:
One defective battery can have such a negative impact
on the charging behaviour of intact batteries of the system
that these too are damaged. The defective battery thus
“infects” the others.
Fig. 4: Remopte monitoring of battery systems via BACS and
monitoring software increases the system‘s stabitity
65
Power Supplies
BACS
BACS
Structure of the overall BACS system:
All batteries in the system are equipped with a control unit
(data collection, battery controller) – the “RTV” module.
The bus system guides all data to the BACS nerve
centre, the core module. This handles the entire
management of the battery pack including signal output.
Detailed functions of the RTV module:
Protection Circuit:
Protects the battery module from over-voltage by destroying an irreversible fuse (conducting path).
Ri-Measure:
Measuring channel and signal conditioning of the internal resistance measurement. Measurement is only active when no equalizing (bypass switched off) occurs.
Voltage Measure:
Measuring channel for voltage measurement.
Bypass:
The bypass channel enables a cross-flow that is used
both for equalizing and as an offset-signal generator. Appropriately deployed resistances serve as a fuse in the
case of a bypass short circuit.
Temp. Measure:
A sensor outside the board records the battery temperature. These data are important for monitoring whether
the thermal range of application is adhered to and at the
same time to initiate any necessary corrections, e.g. of
the final charging voltage.
Controller:
The controller records, controls and processes all signals and data. Additionally, it secures data exchange
via the communication channel.
66
Indication:
The integrated LED displays the operational readiness
of the module via a flashing signal. Other optical messages are conceivable.
Communication Port:
The galvanically isolated communication channel enables data exchange with parent systems; the connection
enables all subscribers to listen, and just one replies to
the central module.
Heat sink:
The electrical energy generated via e.g. equalizing is
dissipated as heat.
Carrier:
A carrier for affixing each RTV module is adapted to
each battery type.
Panel:
Board for the RTV module electronics.
Batteries
Classification of the RTV modules
The battery modules (RTVC001 to RTVC004) are
designed exclusively for lead batteries with a nominal
connection voltage of 12V. The description section
CXXX specifies the corresponding capacity class.
This guarantees that the module type (RTVCXXX) is
suited to the intended battery capacity. The following
RTV modules are available:
Class:
Capacity range: (battery
capacity)
Resistance range: (internal
resistance measurement)
IB/[A]*
IP/[A]**
C001
7 – 12Ah
1.1 – 110mΩ
0 – 0.1
0.2
C002
>12 – 28Ah
1.0 – 100mΩ
0 – 0.3
0.6
C003
>28 – 65Ah
0.6 – 60mΩ
0 – 0.8
1.6
C004
>65 – 200Ah
0.3 – 30mΩ
0–3
4.6
Module C004
Single module
detail: board with temperature sensor
Modules integrated into battery line
Module C001
Single module
Modules integrated into battery line
Battery line on rail prepared for
integration into a Quasar
Single batteries
Module C003 on
BTL12-45 battery
Module C004 on
BTL6-100 battery
67
Power Supplies
BACS
BACS
Descriptions of the core GX module (BACS
Webmanager)
In summary, the BACS Webmanager provides the
following functions:
The BACS WEBMANAGER is the core of BACS. The
module both provides the link to parent systems (PC,
server, web) and also controls all battery modules located in the system. The collected data are managed
and saved, and statuses are correspondingly displayed
or signalled. The text output on the display is limited to
a few messages (several alarms or statuses or current
actions). Important data are transferred to the parent
WEBMANAGER system and statistically processed accordingly.
‧ Management of all BACS modules/ communication
with up to 150 modules (module bus)
‧ Simple display of the operating statuses/ alarms via
the LCD display (16x2 key for scrolling in the display,
LED for optical control of the function and as a warning
notice (red “fault” LED)
‧ Acoustic signalling
‧ Alarm output (relay contact)
‧ “Real-time clock” for linking/ measuring time and data
‧ Bulk storage (CF card) for archiving the data over a
long period (min. 2-10 years, depending on the size
of the CF card)
‧ Hardware and software “watchdog” for monitoring the
Webmanager’s own operating safety. Signal output via
alarm contact
‧ Ports provided: 2x RS232, 1x Ethernet
‧ 5V DC input for general module power supply
‧ I²C bus between the web target, the peripheral
manager and the BACS modules
The BACS WEBMANAGER can manage up to 150
modules. The BACS WEBMANAGER is supplied as an
external unit in its own housing. The “bare” BACS WEBMANAGERS (without casing) can be installed inside the
unit if customers require this version. The BACS WEBMANAGER can thus be directly integrated into a UPS or
battery pack, for instance.
68
Batteries
BACS and communication via the Webmanager
Software and functional scope:
As a rule the CS121 chip takes precedent over the entire
functionality of the core GX module. The CS121 chip
essentially handles administration in the same way as the
classic USV CS121 SNMP web adapter, the difference
being that a BACS system is monitored in this case.
The web browser is also used to set the battery
parameters to adapt each module to the specifics of the
battery manufacturer.
The web browser displays a warning (yellow) for
batteries that are weak or about to fail. As soon as a
certain threshold value is crossed, the symbol turns red
and a system alarm is activated (acoustically and via the
network, e.g. as an e-mail).
For the graphical evaluation of the data, either a custom
EXCEL file can be created or the user can use the
BACS VIEWER, an external Windows program that can
read the data across the network and display them graphically. BACS VIEWER is available as freeware.
Specifications
Specifications
BACS module:RTV C001 xxxx:
RTV C001 xxxx:
RTV C002 xxxx:
RTV C003 xxxx:
RTV C004 xxxx:
Input voltage (nominal):
Input voltage range:
Precision (V measurement):
Valid block voltage range:
“Shut off“- current (RTV):
Module power consumption:
12V
7–23V
<0.5%
9V <UBlock <15V
8V
12V
7–23V
<0.5%
9V <UBlock <15V
8V
12V
7– 23V
<0.5 %
9V <UBlock <15V
8V
12V
7–23V
<0.5%
9V <UBlock <15V
8V
Approx. 100mW
Approx. 100mW
Approx. 100mW
Approx. 100mW
7–12Ah
Lead: vlies, gel
12 – 28Ah
Lead: vlies, gel
28–65Ah
Lead: vlies, gel
65–200Ah
Lead: vlies, gel
0.1A
0.3A
0.8A
3A
Bypass current (R meas.):
Internal resistance (nominal):
Internal resistance measurement
range:
Precision (R measurement) :
0.2A
20–13mΩ
1.1–110mΩ
<3%
0.6A
13–7mΩ
1.0–100mΩ
<3%
1.6A
7–4mΩ
0.6–60mΩ
<3%
4.6A
4–2.7mΩ
0.3–30mΩ
<3%
Operating temperature:
Temperature measurement range:
Valid temperature range:
Precision (T measurement) :
TU [0–55]°C
TRange [-5–60]°C
TBlock [0–45]°C
<4%
TU [0–55]°C
TRange [-5–60]°C
TBlock [0–45]°C
<3%
TU [0–55]°C
TRange [-5–60]°C
TBlock [0–45]°C
<3%
TU [0–55]°C
TRange [-5–60]°C
TBlock [0–45]°C
<3%
Serial, RS232 / 5V
4800 baud
Serial, RS232 / 5V
4800 baud
Serial, RS232 / 5V
4800 baud
Serial, RS232 / 5V
4800 baud
Battery capacity:
Battery type:
Max. bypass current eff. (equalise):
Communication / level:
Communication speed:
69
Power Supplies
DC UPSUPS
DIN rail DIN rail
DC
12VDC–48VDC, 150-500W
For installation in electrical control cabinets, on DIN rails or
anywhere that protected 24V (or 12V and 48V) is required;
for instance for entry-control systems, manufacturing and
process control systems.
The EFFEKTA® battery with 7/12/18Ah is connected to
the UPS and supplies fully uninterrupted load up to the
end of cell voltage in case of a mains failure. The battery is
optionally available in a DIN roptional ail cabinet.
70
Features
. Compact construction
. Redundant parallel switching possible from 300W
. Alarm outputs for mains fail, battery low and
.
.
.
.
remote off
Output voltage internally adjustable for lowmaintenance and maintenance-free battery types
Temperature-regulated charging voltage
Status indication with LEDs
Surge protection
AC/DC power supplies, chargers, inverters / rectifiers
Specifications
Specifications
Specification
Input voltage
Output voltage (nominal)
Output voltage (physical)
L.V.D. threshold
Output current nominal
Power ( w/o battery)
Recommended batt. capacity
Dimensions (H x W x D in mm)
Weight (w/o battery)
Operating temperature
Signals
Displays
Service
Safety
EMI
DT0/012
12V
13.6V
10.5V
12A
144W
21A
252W
105x210x85
1.6kg
1.6kg
DC UPS on DIN rail
DT0/024
DT0/048
90…264VAC, 47…63Hz
24V
48V
27.2V
54.4V
21V
42V
5.6A
7.4A
11A
18A
3A
4.2A
6.25A
134W
178W
264W
432W
144W
202W
300W
5…18Ah
105x210x85
133x240x85
133x250x85
105x210x85
133x240x85
1.6kg
1.7kg
2.3kg
2.8kg
1.6kg
1.7kg
2.3kg
0…40°C, battery up to +30 °C
Dry contacts: Mains fault, dc low voltage
LED green “Operation“, red LED “Mains fault“, red LED “Battery weak“
Switsch for: “Output on/off“, “Automatic restart on/off“
EN60950, EN50091-1-2
EN61000-6-1, EN61000-6-3
10A
480W
133x250x85
2.8kg
BT 12-12 (12Ah)
BT 12-5 (5Ah)
BT 12-7.2 (7.2 Ah)
Dimensions / weight
(H x W x L in mm)
L.V.D.
voltage
5Ah
107 x 70 x 90 / 2.1kg
2x (107 x 70 x 90) / 4.2kg
4x (107 x 70 x 90) / 8.4kg
Batteries
BT 12-18 (18Ah)
Back-up time in minutes at load (current)
8A
10A
2A
4A
6A
10.5V
21V
42V
105
50
25
15
7
10.5V
21V
42V
2A
4A
6A
8A
10A
12A
14A
7.2Ah
101 x 65 x 151 / 2.7kg
2x (101 x 65 x 151) / 5.4kg
4x (101 x 65 x 151) / 10.8kg
150
65
38
25
20
13
7
10.5V
21V
42V
2A
4A
6A
8A
10A
12A
14A
16A
18A
12Ah
101 x 98 x 151 / 4.2kg
2x (101 x 98 x 151) / 8.4kg
4x (101 x 98 x 151) / 16.8kg
295
140
84
54
39
31
25
20
18
10.5V
21V
42V
2A
4A
6A
8A
10A
12A
14A
16A
18A
20A
18Ah
167 x 88 x 181 / 5.7kg
2x (167 x 88 x 181) / 11.5kg
4x (167 x 88 x 181) / 23kg
470
200
121
93
66
48
40
34
29
26
71
Power Supplies
DC power
supply
DC
power
supply
DC ST601
-48 / 60V power supply system including:
‧ 1U 19IN shelf
‧ Max. 2 x 600W rectifier
‧ Power distribution
‧ Controller
Description
Main features
The DC ST601 power supply system is designed for
various applications such as digital access, wireless
base stations, microwave links as well as PABX. Numerous options provide solutions for global applications
in different environments.
‧
‧
‧
‧
‧
‧
‧
‧
The integrated modular power system allows flexible
adaptations. It contains up to 2 rectifiers GR 600 with 48
or 60V, AC- and up to 6 separate protected DC-connections, battery fuses LVD, and power system controller.
These features together with the very short depth are
the key factors for the success of this power system,
offering cost-effective and reliable solutions.
This compact and high density power supply system is
the perfect choice for space-critical locations.
Rear view
72
19” / 1U shelf power system up to 1200W
High power density
Very short depth
Fits into 300mm deep ETSI cabinets
Fan cooled rectifiers GR 600 (48 or 60V)
Integrated power distribution
Easy installation
Dimensions (h x w x d) 44.45 x 430 x 280mm
Applications
‧
‧
‧
‧
‧
‧
DC UPS systems
Digital subscriber line (DSL)
Fiber in the loop
Transmission
PBX
Network components
Modular DC power supply systems 48-60V
Specifications
Specifications
Optional accessories
Software
Programming cable
Blank panel
Right hand picture: rear view of rectifier module GR 600
On the far right: front view of rectifier module GR 600
General
48V-version
60V-version
Load distribution
48V-version
60V-version
Efficiency
≥92%
≥92%
Fuses (DIN 72581-3)
4 pieces / 1 … 30A
4 pieces / 1 … 30A
PLD
None
None
EMI, radiated
EN 55 022, class B
EN 55 022, class B
Safety
EN 60 950, class I
EN 60 950, class I
Cooling
Fan cooled
Fan cooled
Battery connection
48V-version
60V-version
Protection
IP 20
IP 20
Fuses (DIN 72581-3)
2 pieces / 40A
2 pieces / 40A
LVD
60A
60A
Mechanics
48V-version
60V-version
Construction
Steel rack
Steel rack
Cabinet standard
19IN
19IN
Width
430mm
280mm
(including handles)
44.45mm (1U)
5kgs / 11lb
(excluding rectifier)
0.9kg / 2.0lb
430mm
280mm
(including handles)
44.45mm (1U)
5kgs / 11lb
(excluding rectifier)
0.9kg / 2.0lb
Input
48V-version
60V-version
AC connection
1 x L/N/PE
1 x L/N/PE
Nominal voltage
230 Vrms
230Vrms
Voltage range
Voltage range,
reduced power
Frequency range
80 ... 300Vrms
80 ... 300Vrms
80 … 130Vrms
80 … 130Vrms
50 / 60Hz
50 / 60Hz
Current nominal
5.8Arms
5.8Arms
Current maximum
12Arms
12Arms
Line current
Meets IEC 1000-3-2
Meets IEC 1000-3-2
Mains terminal
Common terminal
Common terminal
Weight, system
Transient OVP
Optional / external
Optional / external
Weight, rectifier
Output
48V-version
60V-version
Voltage, nominal
-48Vdc
-60Vdc
Voltage range
-42 …-58Vdc
-52 …-72Vdc
Output current
25Adc
20Adc
Current limitation
28Adc
22Adc
Power, limitation
2 x 600W
2 x 600W
Power, nominal
1200W
1200W
Control and monitoring
48V-version
60V-version
Power, redundant
600W
600W
Controller
PSC 1 / 3
PSC 1 / 3
Power, at 88Vrms
800W
800W
See brochure/data sheet of power system controller
Depth, overall
Height, overall
Environment
48V-version
60V-version
Operation temperature
-25 … +65°C
95% max., non condensing
-25 … +65°C
95% max., non condensing
Relative humidity
73
Power Supplies
DC power
supply
DC
power
supply
DC ST602
-48 / 60V power supply system including:
‧ 2U 19IN shelf
‧ Max. 4 x 600W rectifier
‧ Power distribution
‧ Controller
Description
Main features
The DC ST602 power supply system is designed for
various applications such as digital access, wireless
base stations, microwave links as well as PABX. Numerous options provide solutions for global applications
in different environments.
‧
‧
‧
‧
‧
‧
‧
‧
The integrated modular power system allows flexible
adaptations. It contains up to 4 rectifiers GR 600 with 48
or 60V, AC- and up to 16 DC-connections, battery
connection and power system controller. These features
together with the very short depth are the key factors for
the success of this power system, offering cost-effective
and reliable solutions.
This compact and high density power supply system is
the perfect choice for space-critical locations.
Rear view
74
19” / 2U shelf power system up to 2400W
High power density
Very short depth (fits into 300mm deep ETSI cabinets)
Parallel redundant operation mode applicable
Fan cooled rectifiers GR 600 (48 or 60V)
Integrated power distribution
Easy installation and programming
Dimensions (h x w x d) 88 x 430 x 282mm
Applications
‧
‧
‧
‧
‧
‧
DC UPS systems
Digital subscriber line (DSL)
Fiber in the loop
Transmission
PBX
Network components
Modular DC power supply systems 48-60V
Upper left picture: Modular
design with up to 4 rectifiers
Lower left picture: model with
automatic circuit breakers
(purpose-built item)
Right hand picture: rectifier
GR 600
Specifications
Specifications
General
600W - 48V
600W - 60V
Load distribution
600W - 48V
600W - 60V
Efficiency
EMI, radiated
≥92%
≥92%
Fuses (DIN 72581-3)
16 pieces / 1… 20A
16 pieces / 1… 20A
EN 55 022, class B
EN 55 022, class B
PLD
None
None
Safety
EN 60 950, class I
EN 60 950, class I
Cooling
Fan cooled
Fan cooled
Battery connection
600W - 48V
600W - 60V
Protection
IP20
IP20
Fuses (DIN 72581-3)
2 pieces / 50A
2 pieces / 50A
LVD
60A
60A
Input
600W - 48V
600W - 60V
AC connection
1 x L/N/PE
1 x L/N/PE
Mechanics
600W - 48V
600W - 60V
Nominal voltage
230Vrms
230Vrms
Construction
Steel rack
Steel rack
80 ... 300Vrms
80 ... 300Vrms
Cabinet standard
19IN
19 IN
Weight, rectifier
430mm
282mm
(including handles)
88.9mm (2U)
5kg / 11lb
(excluding rectifier)
0.9kg / 2.0lb
430mm
282mm
(including handles)
88.9mm (2U)
5kg / 11lb
(excluding rectifier)
0.9kg / 2.0lb
Environment
600W - 48V
600W - 60V
Operation temperature
-25 … +65°C
95% max.,
non condensing
-25 … +65°C
95% max.,
non condensing
Voltage range
Voltage range,
reduced power
Frequency range
80 … 130Vrms
80 … 130Vrms
Width
50 / 60Hz
50 / 60Hz
Depth, overall
Current nominal
11,5Arms
11,5Arms
Height, overall
Current maximum
24Arms
Meets
IEC 1000-3-2
Common terminal
Weight, system
Mains terminal
24Arms
Meets
IEC 1000-3-2
Common terminal
Transient OVP
Optional / external
Optional / external
Line current
Output
600W - 48V
600W - 60V
Voltage, nominal
-48Vdc
-60Vdc
Voltage range
-42 …-58Vdc
-52 …-72Vdc
Control and monitoring
600W - 48V
600W - 60V
Output current
50Adc
40Adc
Controller
PSC 1 / 3
PSC 1 / 3
Current limitation
56Adc
44Adc
Power, limitation
4 x 600W
4 x 600W
Optional accessories
Power, nominal
2400W
2400W
Software
Power, redundant
1800W
1800W
Programming cable
Power, at 88Vrms
1600W
1600W
Dummy cover
Relative humidity
75
Power Supplies
GR 600 600
GR
Rectifier 48 / 60V, 600W
Left hand image: rear view
Right hand image: front view
Description
Main features
GR 600 is a single phase, hot-pluggable, fan-cooled
rectifier. The outstanding power density of this product
offers the optimum shelf solutions with 1U shelf DC
ST601 and 2U shelf DC ST602.
‧
‧
‧
‧
‧
‧
‧
‧
The short depth and extended operating temperature
range support compact installation in space critical
pole-mount applications. The high efficiency supports
the operator’s effort for energy saving for the backup
power solution and requires less cooling energy due to
the low losses. The very low audible noise is the key
factor for installations in urban areas. Together with the
advanced controller, the power solution offers additional
benefits to optimize the running cost of the total site.
The typical applications for this rectifier are both in
indoor and outdoor environments, which is a perfect
solution for digital subscriber line (DSL), transmission,
wireless infrastructure, core network components,
telecommunication networks and data networks.
76
Space saving - Very high power density (up to 14W/in3)
Energy saving - High efficiency up to 92%
Easy installation - Hot pluggable, connectors at the rear
Low audible noise - Fan cooled with speed control
Wide input voltage range 80 … 300Vrms
Protection against loss of Neutral and AC overvoltage
Power factor correction - Sinusoidal input current
Optimized power availability to recharge batteries Constant output power characteristic
‧ Operating temperature range up to 75°C (167ºF)
Applications
‧
‧
‧
‧
Digital subscriber line (DSL)
Transmission, PBX
Fiber in the Loop
Wireless base stations, Network components
Modular DC power supply systems 48-60V
Specifications
Specifications
Top picture:
Output characteristics 600W, 60V
Top picture:
Output characteristics 600W, 48V
General
600W, 48V
600W, 60V
User interface
Efficiency
Losses max.
Safety
≥92%
90W
EN 60 950, class I
UL 60 950 / CAN /
CSA – C22.2
EN 55022, class B
ETSI EN 300386
Fan cooled
14W/in3
50dB(A)
Output current display
LED-bar
Status indication
EMI, radiated
Compliant with
Cooling
Power density
Acoustic noise
≥92%
90W
IEC 60 950, class I
UL 60 950 CAN /
CSA – C22.2
EN 55022, class B
ETSI EN 300386
Fan cooled
14W/in3
50dB(A)
LED «ok»
LED «OVP»*
LED «Over temp»*
LED «Fan failure»*
*Indications in LED bar
Input
600W, 48V
600 W, 60 V
Voltage range
Volt. range, red. power
Inrush current
Current maximum
Line current
Harmonic distort. THD
Power factor
EMI, conducted
Mains connector
Input protection
Input switch
AC overvoltage protection
80 … 300Vrms
80 … 184Vrms
20Apeak
6Arms
IEC 1000-3-2
< 5%
~ 1.0
EN 55022, class B
Rear side
Internal fuse 2 x 8A
None
Incl. loss of neutral
80 … 300Vrms
80 … 184Vrms
20 peak
6Arms
IEC 1000-3-2
< 5%
~ 1.0
EN 55022, class B
Rear side
Internal fuse 2 x 10A
None
Incl. loss of neutral
Output
600 W, 48 V
600 W, 60 V
Voltage, nominal
Volt. adjust range
Voltage regulation
Overvoltage protection
Ripple + Spikes
Psophometric noise
EMI, conducted
Current limit, nom.
Limit adjustment range
Load sharing
Power limit
Output connector
53,5Vdc
42 … 58Vdc
±250mVdc
59±1Vdc
≤100mVp-p
≤1.5mVrms (weighted)
EN 55022, class A
14Adc
0 … 14Adc
<±1Adc
600W, fixed
Rear side
66,9Vdc
52 … 72Vdc
±250mVdc
73±1Vdc
≤100mVp-p
≤1.5mVrms (weighted)
EN 55022, class A
11,2Adc
0 … 11,2Adc
<±1Adc
600W, fixed
Rear side
Output protection
Internal fuse 20 A
Internal fuse 20 A
Systemcontroller
PSC 1000
PSC 1 / 3 (See brochure/data
sheet of power system controller)
Voltage programming
Rectifier fail alarm
Voltage programming
Current limit programming
Power limit programming
Rectifier fail alarm
Rectifier start up
Rectifier on/off
Separate charge
Right hand picture:
System controller PSC 1
Environment
Temperature
-25 … +75°C (-13 … +167°F)
Power derating
+65 … +75°C (+149 … +167°F)
Relative humidity
95% max., non condensing
Mechanics
600 W, 48 V
600 W, 60 V
Width, overall
40.5mm (1U)
40.5mm (1U)
Height, overall
86.4mm (2U)
86.4mm (2U)
Depth, overall
231.9mm
231.9mm
Weight
0.9kg
0.9kg
77
Power Supplies
DC power
supply
DC
power
supply
DC ST1603
-48 V power supply system consisting of:
‧ 3U Shelf
‧ Max. 4 x 1600W rectifiers
‧ Power distribution
‧ Controller
Description
Features
The DC ST1603 is a power supply system for -48V with
a maximum power up to 6400W with 3-phase input.
‧
‧
‧
‧
‧
‧
‧
‧
The integrated modular power system allows flexible
adaptations. It contains up to 4 rectifiers of type GR
1600, AC- and DC-connections, battery connection and
power system controller PSC 1 / PSC 3. Other configurations are available on request.
These features together with the very compact depth are
the key factor for the success of this power system and it
offers cost-effective and reliable solutions.
This power supply system is designed for various
applications such as digital access, wireless base
stations, microwave links as well as PABX. Feel free to
ask for individual solutions.
78
Modular design
19”- 3U rectifier-shelf (standard) + controller PSC1/3
Easy connecting and mounting of shelf
Fan cooled rectifiers GR 600 (48 or 60V)
Hot pluggable
All connectors at the rear
Efficiency ≤ 92 %
Integrated power distribution
Applications
‧
‧
‧
‧
‧
Digital subscriber line (DSL)
Transmission
PBX
Wireless base stations
Network components
Modular DC power supply systems 48-60V
Specifications
Specifications
Optional accessories
Software
Programming cable
Dummy cover
Options
Number of rectifiers
1…4
AC connections
3L+PE (220 / 240Vrms L-L)* L + N + PE
Display
System voltage, current
Transient OVP
for 3L + N + PE (external)
Right hand picture:
Rectifier GR 1600
General
Load distribution
Efficiency
≥ 91 %
Fuses (DIN 72581-3)
9 MCBs, 1 ... 63A
EMI, radiated
EN 55 022, class B
LVLD
no
Safety
EN 60 950, class I
Cooling
Fan cooled
Battery connection
Input
Fuses (DIN 72581-3)
2 MCBs, 125A max.
LVD
Optional
AC connection
3 x L + N/PE
Nominal voltage
3 x 230 / 400Vrms
Voltage range
88 ... 300Vrms
Mechanics
Range,
reduced power
88 …184Vrms
Construction
Steel rack
Frequency range
50 / 60Hz
Cabinet standard
19IN
Current nominal / phase
(4 rectifiers)
19A
Width, body
450.5mm
Current maximum
< 30Apeak
Depth, overall
272mm (incl. grab handle)
Line current
meets IEC 1000-3-2
Height, overall
133mm (3U)
EMI, conducted
EN 55 022, class B
Weight, system
9 kg (without rectifiers)
Mains terminal
Terminal Block
Weight, rectifier
1.25kg each
Transient OVP
Optional / extern
Environment
Output
Voltage, nominal
53.5Vdc
Operation temperature
-25 … +65°C
Operation temperature
(reduced power)
65 … +75°C
Relative humidity
95% max., non condensing
Protection
IP 20
Voltage adjust range
42 …58Vdc
Voltage error, static
± 250mVdc
Overvoltage protection
59V ± 1V
Ripple + Spikes
≤ 200mVp-p
Psophometric noise (weighted)
≤ 1.0mVrms
EMI, conducted
EN 55 022, class A
Control and monitoring
Power, nominal (4 rectifiers)
6400W
Controller
Power, redundant (3 rectifiers)
4800W
See brochure/data sheet of power system controller
PSC 1 / 3
79
Power Supplies
GR 16001600
GR
Rectifier 48V, 1600W
Left hand image: rear view
Right hand image: front view
Description
Main features
GR 1600 is a single phase, hot-pluggable, fan-cooled
48V rectifier. The outstanding power density of this product offers the optimum 1U or 3U 19IN shelf solutions.
‧
‧
‧
‧
‧
‧
‧
‧
‧
The short depth and extended operating temperature
range support compact installation in space critical polemount applications. The high efficiency supports the
operator’s effort for energy saving for the backup power
solution and requires less cooling energy due to the low
losses. The very low audible noise is the key factor for
installations in urban areas. Together with the advanced
controller, the power solution offers additional benefits to
optimize the running cost of the total site.
The typical applications for this rectifier are both in
indoor and outdoor environments, which is a perfect
solution for digital subscriber line (DSL), transmission,
wireless infrastructure, core network components,
telecommunication networks and data networks.
80
Space saving - Very high power density 24W/in3
Energy saving - High efficiency 92%
Easy installation - Hot pluggable, connectors at the rear
Low audible noise - Fan cooled with speed control
Wide input voltage range: 88 - 300Vrms
Protection against loss of Neutral and AC overvoltage
Power factor correction - Sinusoidal input current
Constant output power characteristic
Operating temperature range up to 75°C (167ºF)
Applications
‧ Digital subscriber line (DSL)
‧ Transmission, PBX
‧ Wireless base stations, Network components
Modular DC power supplies 48-60V
Specifications
Specifications
Optional accessories
Single backplane
Triple backplane
Blank panel
D0106218
D0112006
D0112127
Environment
Temperature
Power derating
Relative humidity
-25 … +75°C (-13 … +167°F)
+65 … +75°C (+149 … +167°F)
95% max., non condensing
Mechanics
Width, overall
Height, overall
Depth, overall
Weight
40.8mm (1.6in, 1U)
132mm (5.2in, 3U)
232.5mm (9.15in)
1.25kg (2.75lb)
General
Efficiency
Losses max.
Safety
EMI, radiated
Compliant with
Cooling
Power density
Acoustic noise
User interface
92%
180W
IEC 60 950, class I
UL 60 950
CAN / CSA – C22.2
EN 55022, class B
ETSI EN 300386
Fan cooled
24W/in3
48dB(A)
Output current display
LED-bar
Status indication
LED «ok»
LED «OVP»*
LED «Over temp»*
LED «Fan failure»*
*Indications in LED bar
System controller
PSC 1000
PSC 1 / 3 (See brochure/data
sheet of power system controller)
Input
Voltage range
Volt. range, red. power
Inrush current
Current maximum
Line current
Harmonic distort. THD
Power factor
EMI, conducted
Mains connector
Input protection
Input switch
AC overvoltage protection
Top image: Block diagram
85 … 300Vrms
85 … 184Vrms
15Apeak
9,5Arms
IEC 1000-3-2
5%
~ 1.0
EN 55022, class B
Rear side
Internal fuse 2 x 15A
None
Incl. loss of neutral
Voltage programming
Rectifier fail alarm
Voltage programming
Current limit programming
Power limit programming
Rectifier fail alarm
Rectifier start up
Rectifier on/off
Separate charge
Output characteristic:
Output
Voltage, nominal
Volt. adjust range
Voltage regulation
Overvoltage protection
Ripple + Spikes
Psophometric noise
EMI, conducted
Current limit, nom.
Limit adjustment range
Load sharing
Power limit
Output connector
Output protection
53,5Vdc
42 … 58Vdc
±250mVdc
59±1Vdc
≤100mVpp
≤1.5mVrms (weighted)
EN 55022, class A
33,4Adc
0 … 33,4Adc
<±2Adc
1600W, fixed
Rear side
Internal fuse 40A
‚Golden finger‘ connector for reliable
1:1 connection to the system bus
81
Power Supplies
DC power
supply
DC
power
supply
DC ST2010
-48 / 60V power supply system consisting of:
‧ 5U shelf for power distribution and controller
‧ 5U shelf for max. 6 x 2000W rectifiers
Left hand picture:
rear view
Right hand picture:
front view
Description
Main features
The DC ST2010 is a very compact 19’’ / 5U shelf for the
rectifier GR 2000 with a maximum power of 12kW and
three phase input.
‧
‧
‧
‧
‧
‧
‧
‧
Due to the modular design the DC ST2010 can be
assembled with up to 6 rectifiers GR 2000. In the power
distribution unit there also can be found the controller,
LVD/PLD, current sensors, battery fuses and up to 15
separately protected DC-outputs. Other configurations
can be easily developed on demand.
These are the key factors of the success of this power
system and it offers a cost-effective and reliable solution.
The typical applications for this rectifier shelf are both
in indoor and outdoor environments, which is a perfect
solution for wireless base stations, core network components, telecommunication networks and data networks.
Please feel free to ask for individual solutions.
82
Modular structure
19’’ rectifier shelf / 5U
Easy to stack shelves
Up to 12 kW installed power
Fan cooled rectifiers FR 48V – 2000W – E
Hot pluggable, all connectors at the rear
Efficiency ≥ 92%
Integrated 3 phase AC terminal (3L + N + PE)
Applications
‧
‧
‧
‧
Indoor and outdoor
Medium to large power systems
Shelf power solutions
Telecom, wireless, Datacom
Modular DC power supply systems 48-60V
Specifications
Specifications
Options
Max. number of rectifiers
AC connection
DC outputs
1…6
3L + N + PE
3L + PE (220 / 240Vrms L-L)*
max. 15
*on request
Optional accessories
Software
Programming cable
Dummy cover
Right hand picture: rear view GR 2000
On the far right: front view GR 2000
General
Efficiency
Losses, max.
Safety
EMC
Cooling
Protection
≥ 92%
1200W (6 rectifiers)
IEC/EN 60 950
EN 300 386-2
Fan cooled rectifiers
IP 20
Input
AC connection
Nominal voltage
Range, full power
Range, reduced power
Frequency range
Current nominal
Current maximum
Inrush current
Line current
Harmonic distort. THD
Mains terminal
Input protection, recommended
Main switch
3L + N + PE
3 x 230 Vrms (L-N)
184 ... 300Vrms
88 … 184Vrms
45 / 66Hz
3 x 19Arms @ 12kW
3 x 24Arms @ 12kW
< 30Apeak each phase
meets IEC 1000-3-2
< 5%
AC cable 5 x 6mm 2 / 5m
MCB 3 x 25A / C-curve
external
Mechanics
Construction
Cabinet standard
Width, body
Depth, overall
Height, overall
Weight, system
Weight, rectifiers
steel frame
19”
437mm
432mm
2 x 225mm (2 x 5U)
20kg
App. 6 x 4.4kg
Environment
Operating temperature
Relative humidity
-5 … +45°C
95% max., non condensing
Control and monitoring
Controller
PSC 1 / 3
See brochure/data sheet of power system controller
Output
Voltage, nominal
Voltage range
Voltage error, static
Overvoltage protection
Ripple + Spikes
Psophometric noise
Nominal current
Current limit, maximum
Power, nominal
Power, redundant
Power, reduced
Output terminal
Output protection
-48 / -60Vdc
-42 … -72Vdc
± 250mVdc
59 / 71V ± 1V
≤ 200mVp-p
≤ 1.0mVrms (weighted)
224Adc 12kW, 53.5V
279Adc @ 12kW, 43V
12kW
10kW
min. 4800W
Copper bar, rear side
Internal fuse each rectifier
Right hand picture:
Customers design system:
2 x 24.000W redundant
(24 rectifiers)
in 600x600x2000mm cabinet
with 2 inputs
83
Power Supplies
GR 20002000
GR
Rectifier 48/60V, 2000W
Right hand picture: rear view
On the far right: front view
Description
Main features
The GR 2000 is an up to date high frequency switched
mode telecom power supply for both 48V and 60V
applications.
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
It consists of two power processing stages. The first
one is a boost based power factor corrector using the
zero current switching technique. The second stage is a
phase shifted full bridge DC/DC converter using state-ofthe-art soft switching technology.
The GR 2000 offers output characteristic with power
limit matching a constant power character of modern
telecom loads and thus reducing the required number of
rectifiers.
The primary applications of the rectifier are modular
power systems for telecommunication equipment.
84
Efficiency ≥ 91%
Compact (500W / l) and light (4.4kg)
Hot pluggable, all connectors at the rear
Fan cooled with air flow monitoring
Wide input voltage range: 88 - 276Vrms
Power factor ~ 1.0 (sinusoidal input current)
Selectable output voltage 48V or 60V
Constant output power characteristic
Analogue system bus
Operating temperature range up to 70°C
Applications
‧
‧
‧
‧
Indoor and Outdoor
Medium to large power systems
Shelf power solutions
Telecom, wireless, Datacom
Modular DC power supply systems 48-60V
Right hand image:
Block diagram
Specifications
Specifications
General
Efficiency
Losses, max.
Safety
EMI, radiated
Compliant with
Cooling
Power density
≥ 91%
200W
EN 60 950, class I
EN 55022, class B
EN 300386-2
Fan cooled
500W/l (8.2W / in3)
Input
Voltage range
Volt. range, red. power
Inrush current
Current maximum
Line current
Harmonic distort. THD
EMI, conducted
Mains connector
Input protection
Input switch
88 … 276Vrms
88 … 184Vrms
< 15Apeak
12Arms
According IEC 1000-3-2
< 5%
EN 55022, class B
Rear side
Internal fuse 2 x 15A
None
Output
Voltage, nominal
Voltage adjust range
Voltage regulation
Overvoltage protection
Ripple + Spikes
Psophometric noise
EMI, conducted
Current limit, nominal
Limit adjustment range
Load sharing
Power limit
Output connector
Output protection
53.5 / 62Vdc
42 … 72Vdc
± 250mVdc
58.5 / 73V ± 1 %
≤ 200mVpp
≤ 1.0mVrms (weighted)
EN 55022, class A
37Adc
0 … 37Adc
< ± 3Adc
2000W, fixed
Rear side
Internal fuse 50A
User interface
Output current display
Status indication
Output voltage
Output current
LED bar
LEDs «ok», «Alarm»
Test jack
Test jack
Power system controller
PSC 1000
PSC 1 / 3 (See brochure/data
sheet of power system controller)
Voltage programming
Rectifier fail alarm
Voltage programming
Current limit programming
Power limit programming
Rectifier fail alarm
Rectifier start up
Rectifier on/off
Separate charge
Mechanics
Width, overall
Height, overall
Depth, overall
Weight
65mm (2.56in)
212mm (8.35in)
346mm (13.62in)
4.4kg (9.7lb)
Environment
Operating temperature
Power derating
Relative humidity
-25 … +70°C (-13 … +158°F)
+60 … +70°C (+140 … +158°F)
95% max., non condensing
Optional accessories
Single backplane
Blank panel
D0100298
D0018281
Output characteristic:
85
Power Supplies
Power SystemSystem
Controller Controller
Power
Controller for power supply systems
DC ST 601 up to DC ST 2010 / rectifiers GR 600 - GR 2000
PSC 1
PSC 3
Description
Description
The PSC 1 is a simple power system controller for small power systems.
It consists of a compact central unit providing basic I/O periphery, and of
an analogue based communication bus to the rectifiers. The user friendly
display quickly displays basic information about the current status of
the power system. The controller’s battery management with regularly
accomplished capacity tests is one of the key factors for the availability of a
power system. The PSC 1 controller allows also remote alarming by means
of potential-free relay contacts.
The PSC 3 is a 3rd generation power system controller for small to very large and complex power systems. It consists of a central unit, which provides
basic I/O periphery, and of a very reliable CAN standard based communication bus. The front end modules are located close to the elements to be
monitored. The benefit is an easy wiring, which is perfect for expandable
power systems with decentralized distributions (BDFB) and batteries in
separate rooms. The integrated PLC offers the flexibility for monitoring and
control of auxiliary devices, later functions upgrade and system capacity
expansions. The PSC 3 allows remote alarming by means of potential-free
relay contacts or via modem or LAN / Ethernet. The SNMP offers enhanced
remote alarming and is designed to work with SNMP managers. An integrated web server offers a user friendly interface for detailed monitoring and
control with a standard web browser.
Features
Features
‧
‧
‧
‧
‧
‧
‧
‧
Float voltage control
Temperature compensation
Battery current limit
Boost charge
Battery test, advanced capacity test
LVD control
Analogue system bus
Simple user interface
Applications
‧
‧
‧
‧
‧
86
Power supply systems
Digital subscriber line (DSL)
Fiber in the loop
Transmission
PBX
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
‧
Modular power system controller
Integrated PLC for flexible system configuration
Easy system expansion
Digital system bus
Enhanced battery management
Remote monitoring with modem or LAN
Integrated web server
SNMP
Energy saving functions
New alarming concepts
Monitoring of auxiliary devices
Advanced site monitoring & control
Applications
‧ Power supply systems
‧ Decentralized power plants
Modular DC power supply systems 48-60V
Top picture: controlling and monitoring
of PSC 3 via WEB browser
Top picture: «PSC 1 Monitor» - program
General
PSC1
PSC3
Functions
PSC1
PSC3
Safety
EN 60 950, class I
UL 60 950
CAN / CSA – C22.2
EN 55 022, class B
EN 300 386-2
Convection
horizontal / vertical
IP20
EN 60 950, class I
UL 60 950
CAN / CSA – C22.2
EN 55 022, class B
EN 300 386-2
Convection
All
IP20
Float voltage control / Temperature compensation
Battery middle point
Battery block voltage, up to 256
Battery current limit, enhanced
Boost charge
Equalise
Battery test, advanced capacity test
LVD and PLD functions, up to 96
Battery deep discharge protection
Mains failure detection
Real time clock
Genset functions
Individual rectifier control
Efficiency mode / Energy saving
Rectifier cycling
Sequential startup
PLC functionality / event generator
200 data log entries
Remote function upgrade
●
●
●
●
●
●
●
●
●
●
●
● (optional)
●
●
●
●
●
●
●
●
EMV, radiated
Compliant with
Cooling
Mounting direction
Protection
Power supply
PSC1
PSC3
Voltage range
Current
EMI, conducted
Input protection
Input switch
18 ... 75Vdc
50 mAdc max.
EN 55 022, class B
Internal fuse
None
18 … 75Vdc
0.75 Adc max.
EN 55 022, class B
External fuse 2A
None
Features
PSC1
PSC3
Rectifier interface
Number of rectifiers
Digital input
Relay output
Temperature
Voltage, current
Analogue
Up to 16
Up to 4
Up to 6
2
Up to 3
Display
LCD
Local monitoring
Remote monitoring
Remote alarming
Web server access
SNMP management
LCD and RS232
None
Dry contacts
None
None
Digital, CAN-based
Up to 128
Up to 225
Up to 97
Up to 96
Up to 96
Up to 2 User interface
modules
LAN/RS232/WEB Browser
LAN/Modem/WEB Browser
Dry contactsSNMP
Up to 4 levels
Standard SNMP manager
Mechanics
PSC1
PSC3
Height, body
Width, overall
Depth, overall
Weight
40.4mm / 1U
83.4mm / 2U
195mm / 7.7inch
0.3kg / 6.6lb
43mm / 1.69inch
86.5mm / 3.41inch
180mm / 7.09inch
0.6kg / 13.2lb
●
●
●
●
●
User interface
PSC1
PSC3
Status indication
LED «Alarm»
LCD with backlight
Rectifier status indication
on each module
None
LED «ok»
LED «alarm»
Environment
PSC1
PSC3
Operating temperature
Relative humidity
-40 … +75°C
-35 … +60°C
-40 … +167°F
-31 … +140°F
95% max., non condensing
Options
PSC1
User interface UIM
(option)
5 configurable LED
LCD display
Keypad
PSC3
None
User Interface Module UIM with
LCD display and keys
Modem interface RS 232
Real time clock
Configuration software
Programming cable
87
Power Supplies
DC-UPS
DC-UPS systems systems
Product Description
The DC Power Rack DCPR 48-66 is specifically designed
for use in telecomunications networks. Fuse-protected
48V power supplies from EFFEKTA® are already in
successful operation in TETRA and TETRAPOL networks
Available versions: 108V and 216 VDC.
Up to 4 rectifier modules PSR308 can be integrated into
the subrack. The unit is equipped with a supervisory
module combined with a fan tablet and DC distribution.
Key Features
. High reliability
. Simple installation and operation
. Forced fan cooling
. USB interface for PC connection
. Alarm contacts for multible configurations
. Intelligent battery management
. CAN-Bus interface
. Hot pluggable controller and DC distribution modules
. Optional Ethernet (SNMP compatible)
.
Front view of DCR PSR 327-10.8
88
interface module
LVD and PLD functionality
Modular DC power supply systems 108-220V
System Components
Rectifier module PSR327:
110 / 220VDC; 2700W; 12.9A / Key Features:
. Single–phase modul with sinusoidal input current (PFC)
. Input overvoltage protection
. Wide input voltage range (100-254 VAC)
. „Hot–Plug–In“ design with backplane connection
. High power density
. CAN– Bus interface
. Integrated decoupling from the DC bus
Controll Unit UPC3 with integrated fan
Key Features:
. Extensive battery management
. Freely programmable signalling concept
. „Hot–Plug–In“ design with backplane connection
. Integration of external alarm structures possible
. Remote controll. + monitoring via direct PC link,
modem or SNMP
. CAN–
Bus interface
Specifications
Specifications
Type
DCR PSR327-xxx
Input voltage
Output voltage
Output capacity
230VAC
110 / 220VDC
8100 / 10800W
Mains
DC output
3 phases, N, PE
Screw connection M10
3 x shunt (60mV); 2 x temperature sensor
1 x battery tapping point, analog inputs on ext. connector board
sensor lead for output voltage
8 x potential-free, common ground
6 isolated relay contacts
Acc. IEC 721-3-3 Klasse 3K3/3Z1/3B1/3C2/3S2/3M2
operation: -20°C up to +55°C
storage: -40°C up to +85°C
transport: -40°C up to +85°C
yes
311 x 483 x 355 mm (HxWxD) 19“ Sub-Rack, 3U
App. 6.1kg without rectifier
app. 3.8kg
Analog inputs
Signalling input
Signalling output
Climatic conditions
Extended ambient temperature range
RoHS-compliance
Dimensions
Weight
Weight rectifier
Front view of DCR PSR 327-8.1
89
Power Supplies
Rectifiers
Rectifi
ers
Switched rectifiers for parallel-redundant power
supply systems of high availability in the energy
sector, telecommunications and industry; hot plugin; processorcontrolled, charging voltages and
characteristic curves can be adjusted manually and
remotely, can be used with all battery types.
Example configuration DCR PSR327-10.8 HV
4 x PSR327-220V
Control unit
UPC3
Controll unit UPC3 with integrated fan
•
•
•
•
•
•
Extensive battery management
Freely programmable signalling concept
„Hot–Plug–In“ design with backplane connection
Integration of external alarm structures possible
Remote controll. + monitoring via direct PC link, modem or SNMP
CAN– Bus interface
Dimensions: 133x101x320 mm (HxWxD)
Weight: app. 1.8kgs
Rectifier module PSR327
Dimensions (HxWxD):
133x106.3x326.5mm
Weight: app. 3.8kgs
Outpt voltage
110 (108)V
220 (216)V
Output current
25A
12.5A
1/4 * 19“ * 3U high to use in racks, all connectors
on rear side, with or without PowerController UPC
selectable, hot-swapable, (Compatible 19” rack: DCR
PSR327-xx)
Rectifier module PSS18
Output voltage
110 (108)V
220 (216)V
Dimensions (HxWxD):
262x142x285mm
Weight: app. 8.4kg
90
Rectifier module
PSR327-110V
Output current
13.3A
6.7A
1/3-19“ * 6U to use in racks as per DIN A 41 494,all
connectors on front side (Compatible 19” rack: DCR
PSS18-xx)
Rectifier module
PSS18-110V
Modular DC power supply systems 108-220V
Inverters
Inverters
Right hand picture: Assembly set 19“ sub
rack 2U incl. backplane for 3pcs. inverters
INV2xx and 1pc. static switch STS207
Left hand picture:
single 110 VDC modulet
Product description
An INV-series inverter includes the newest switching
technology with digital control. Due to this fact a
dramatic reduction of volume and weight was achieved.
With a state-of-the-art control solution it provides an
excellent functionality and several protection features.
The inverter is able to run in parallel operation mode to
increase the reliability of the AC system without any
additional options. Additional modules can be integrated
in wired slots during normal system operation. For
higher reliability the hard wired synchronization bus
between paralleled inverters is working in a redundant
mode.
Up to 4 inverters can be installed in a 19”-subrack with
only 2U. The module is prepared to operate with the
new static switches of the STS series to increase the
system availability furthermore.
Key features
. 1/4 x 19‘‘, 2U
. Excellent overall efficiency and high regulation speed
. “Hot plug-in“ design with backplane connection
. High power density
. CAN-Bus interface
. Ability for parallel operation
. Temperature-controlled fan cooling
. Redundant synchronization bus
. Excellent sinusoidal output
. Input over/under voltage shutdown, overload
and short circuit-proof
Available versions:
Type
input
output
capacity
INV222
110VDC
230VAC
2.25kVA
INV222
220VDC
230VAC
2.25kVA
91
Power Supplies
Charger
Charger
NEU / NEW
EFFEKTA® CHA-series
Description
12, 24 and 48V Charger
The EFFEKTA® chargers offer a rapidly and gently charging process with IUoU-characteristics. Thereby they are
ideal for charging lead-gel, lead-acid and AGM batteries.
This 3-steps constant current charging in professional
quality, batteries charge faster and more gently than
comparable units on the market, whereby the service life
of the batteries significantly increase.
92
With the IUoU-characteristics, charge occurs with
constant current until the gasing voltage. After a certain
gasing time the voltage reduces to trickle charge.
Features
Hereby each battery can be charged up to its maximum
capacity.
‧
‧
‧
‧
Reverse polarity- and short circuit protection
Overload protection
IUoU-charging characteristic
High efficiency through switching power supplytechnology
‧ Temperature-controlled fan
‧ 24 months‘ warranty
AC power supply, chargers
Specifications
Specifications
12 V - Model
Input voltage
Frequency
Output voltage
Charging end voltage
Charging maintenance voltage
Charging current max.
Operating temperature
Weight
Dimensions (H x W x D in mm)
CHA 012-012
12A
25A
0-50°C
2.1kg
82 x 205 x 230
24 V - Model
Input voltage
Frequency
Output voltage
Charging end voltage
Chrging maintenance voltage
Charging current max.
Operating temperature
Weight
Dimensions (H x W x D in mm)
48 V - Model
Input voltage
Frequency
Output voltage
Charging end voltage
Charging maintenance voltage
Charging current max.
Operating temperature
Weight
Dimensions (H x W x D in mm)
CHA 012-025
230VAC ± 10%
50Hz
12VDC
14.4VDC
13.6VDC
2.7kg
82 x 205 x 290
CHA 024-008
CHA 024-014
230VAC ± 10%
50Hz
24VDC
28.8VDC
27.2VDC
8A
14A
0-50°C
2.1kg
82 x 205 x 230
2.7kg
82 x 205 x 290
CHA 048-008
230VAC ± 10%
50Hz
48VDC
57.6VDC
54.4VDC
8A
0-50°C
2.7kg
82 x 205 x 290
Right picture: rear view of EFFEKTA® charger model 24-14
(24V, 14A) with fan, solid cable and fuse
93
Power Supplies
Chargers
Chargers
Switch-mode chargers for lead-acid
batteries, with IUoU-characteristic, timer for
float charge, low ripple, leads with battery
clips, waterproof (IP67) version available
Nominal
voltage
Output
current
135x80x44mm (L x B x H) app. 350g
12V
24V
4A
2A
(no pic.) 184x171x54mm(LxBxH) app. 1.7kg
Nominal
voltage
12V
24V
36V
48V
Output
current
10A
5.0A
3.3A
2.5A
Nominal
voltage
Output
current
12V
24V
20A
10A
MA2040
MA9740
MA2045
MA 2040
MA 2045
215x186x63.5mm (LxBxH) app. 2.2kg
Mascot AC/DC plug-in units
switch mode:
MA9725
AC/DC plug-in units with universal input
voltage and high efficiency, short circuitproof, output cables with exchangeable
plugs, EN60601 on request.
75x32x40mm
(LxBxH) app. 65g
MA9619
100x63x47mm
(LxBxH) 250g
Output
voltage
5V
6V
7.5V
9V
12V
Output
current
1A
1A
0.7A
0.6A
0.6A
Output
voltage
7.5V
9V
13V
18V
24V
Output
current
3.0A
2.8A
2.4A
1.7A
1.3A
MA9725
MA9619
Mascot AC/DC power supplies
switch mode:
AC/DC power supplies, primary switched,
short circuit-proof, 190-264VAC / 260-340VDC,
6.3mm push-on terminals, inc. earth, cable,
hand lamp or cigarette lighter plug, output
voltage adjustable on charging voltage.
MA9120
122x77.5x42mm
(LxBxH) app. 400g
MA8921
215x151x62mm
(LxBxH) 1.55kg
Output
voltage
7.5V
9V
10V
12V
25V
Output
current
3.0A
4.5A
3.5A
2.7A
2.0A
Output
voltage
Output
current
12V
20A
24V
12A
48V
6A
MA9120
MA8921
94
AC/DC
DC/DC convertersconverters
DC/DC
For use as a mains source in cars, boats and for other mobile applications.
MA8662
MA8862
Switched mode DC/DC converter, output isolated for vehicle use
135x119x46mm
(LxWxH)
app. 600g
Input voltage
Output voltage
Power contin.
Peak power
18-32V
13.2 / 24 / 48V
81W
132W
MA8662
Linear regulated CD/DC converter for vehicle use
Input voltage
20-32V
129x115x62
Output voltage
13.5V / 6A
mm
Power contin.
80W
(LxWxH)
app. 500g
Peak power
100W
Available types:
Input range
Fixed output
Contin.current
10-16V
13.2V
3A
10-16V
24V
1.7A
10-16V
48V
0.7A
18-32V
13.2V
6A
18-32V
24V
3A
18-32V
36V
2.5A
18-32V
48V
1.5A
30-48V
13.2V
6A
30-48V
24V
3A
MA8862
MA9970
Switched mode DC/DC converter, output isolated for vehicle use
MA9970
203x102x63mm
(LxWxH)
0,9kg
Input voltage
Output voltage
Power contin.
20-30V
13.8V
276W
Peak power
317W
MA9970
95
Power Supplies
Solar inverter
ES-series
Solar
inverter
ES-series
NEU / NEW
Grid-connected
ES3300 – 3000watt
ES4200 – 4000watt
ES5000 – 5000watt
The EFFEKTA® ES inverters with an output power of
3000 up to 5000Watt are ideally suitable for several solar
modules. With its robust assembly in dustproof IP65
cabinet, the application range is nearly unlimited.
Features
‧ Transformer-less with high efficiency (96%)
‧ Wide range of working temperature:
-25°C bis +50°C
‧ Intelligent MPP-Tracking
‧ Suitable to operate either indoor or outdoor (IP65)
‧ Fan-less through convection cooling
‧ RS232-communication
‧ Wide communication equipment:
Slots for RS485 USB,
relays card or TCP/IP
‧ 5 years‘ warranty
(optionally expandable to 10 years)
Comfortable multifunciton panel
1. LCD-Display
2. Warning-LED rounding failure
3. Warning-LED supply failure
4. LED-display supply OK
5. Access functions
6. Click back
7. Click forward
8. Confirm
1
2
3
4
Slot for optional communication cards
96
5
6
7
8
Solar inverter
Easy and secure mounting with carrier plate
Sample configuration:
DC-connection clamp for one 2-String-PV-array
Specifications
Specifications
Model
Inverter
technology
DCinput
ACoutput
Efficiency
Environment
Mechanic
Communicaion
Frontpanel
Implementation
Isolation method
Nominal voltage
Max. input voltage
Operating voltage
Max. current (each MPP-Tracker)
MPPT range
MPPT tracker
Nominal power
Max. power
Nominal voltage
Form of the output connection
Voltage range
Nominal current
Frequency
Power factor
Harmonic distortion
Max. efficiency
EURO efficiency
CEC efficiency
Operating temperature
Humidity
Audible noise
Dimensions (H x W x D in mm)
Weight (kg)
Enclosure
Cooling
AC connection
DC connection
Standard
Optional
LCD
LED
Safety
Certification
Keyboard
Mains supply
Short circuit
EPO
Over temparature
Safety
EMI/EMC
ES3300
ES4200
ES5000
sine-wave, current source, change-/high-frequency PWM
version without transformer*
360VDC
500VDC
120VDC to 500VDC**
22A
14A
17.65A
150VDC to 450VDC
1
2
3000
4000
4600
3300
4200
5000
230 VAC adjustable on 200/208/220/230/240
1-phase, mains connection (L, N, PE)
184 to 264.5 VAC (basic 230 VAC)
13A
17.7A
21.7A
50/60Hz, autoselect
>0.99 with nominal AC
total harmonic distortion: under 5%
single harmonic distortion: under 3%
>96%
>94%
>94%
-25°C up to +50°C (-13°F up to +122°F)
0 to 90% (without condensation)
<45dBA
455 x 430 x 170
455 x 510 x 170
25
29
IP65, outdoor operating
convection
terminal
multiple, pluggable
RS232
USB, RS485, potential fee contact, TCP/IP
input DC voltage/input DC current/input DC current capacity/
output AC voltage/output AC current/output frequency/output AC current capacity/
energy output/inside temperature/cooling body temperature/status signal/failure signal
red:
grounding failure or DC-input insolation failure
yellow: supply conditions are not comply with input values of photovoltaic inverter
green: solar cell energy is higher or lower than 5% of nominal capacity of the photovoltaic inverter
up button/down button/function button/enter-button
over-/under voltage, over-/under frequency, grounding failure, DC-input isolation failure, off-grid operation
AC input: input diode/electronical switching
AC output: output relay/electronical switching
photovoltaic inverter switches off immediately
≤50°C (122°F) at full power/≥50°C (122°F) at reduced power
Europe VDE0126-1-1, EN50178, IEC62103
EN61000-6-1, EN61000-6-2, EN61000-6-3, EN61000-6-4
*no galvanic isolation – note installation introduction of the solar-panel manufacturer..
**nominal range should be from 150 VDC up to 500 VDC to achieve the nominal capacity.
97
Power Supplies
Solar-Log Monitoring
Solar-Log
TM
TM
Remote diagnostic system for
EFFEKTA® solar inverter ES
NEU / NEW
Te microcomputer Solar-LogTM offers the owner or installer
an easy installation coupled with a large range of functions
for their photovoltaic system.
Solar-Log200 for
1 inverter
Solar-LogTM enables you to monitor and manage your photovoltaic system yourself. The main focus is on performance and yield
control. Selectable display methods, data security and our free web
based service are further plus-points that speak for Solar-LogTM.
Solar-LogTM constantly monitors the performance of each and every
inverter/string and evaluates the status messages. Specific alert
message protocols allow fast response times and prevents loss of
revenue.
Features and advantages
‧ Low cost – high benefit
‧ Easy installation and operation
‧ Solar-Log500 provides up to 10 inverters
‧ Solar-Log1000 provides up to 100 inverters
‧ Endless, consistent data logging
‧ Centralized monitoring, remote configuration of
multiple plants (via optional portal connection)
‧ Operating with touch-screen or web-browser in a
network
‧ Service-orientated monitoring and analysis options
‧ User-friendly visualization of plant data
‧ Low losses of profit
‧ Earnings forecast
‧ Degradation of modules calculation
‧ Made in Germany
‧ 5 years warranty
98
Solar-Log500 for up to
10 inverters
Solar-Log1000 for up to
100 inverters
Solar inverter
Event log retrievable via PC for detailed Diagnosis of Inverter
(German language screenshot
Graphical and tabulation view of daily, monthly and total values, reference value for annual yield, input voltage in daily view available.
(German language screenshot).
Specifications
Specifications
Model
Inverter communication / inverters
Max. number inverters
Communication interfaces
Inverter-mixed mode
Maximum unit size
Maximum cable length
Bluetooth2)
Power management2)
System monitoring
String monitoring (dependant on inverter-type)
Inverter breakdown
Performance monitoring per inverter
Status / error monitoring
Sensor connection (Irradiation / 2 x Temp. / Wind)
Connection of digital electric meters
Email and SMS alert
Local alert (floating contact)
Income forecast
Degradations calculation
Visualization
Integrated web server
Graph. visualization - local PC
Graph. visualization - USB strick
Graph. visualization - Internet
LED status indicator
Display on device
Operation on device
Large display RS485 / S 0-Impuls
Interfaces
Ethernet - Network
USB stick
Analog modem / GPRS (GSM) / DSL
Floating contact (relay)
Alarm contact (theft)
General data
Power supply / Voltage
Electricity consumption
Ambient temperature
Case
Dimensions (H x W x D) in cm
Installation
Protection
Connection to Solar-LogTM Portal
Multiple languages (DE, EN, ES, FR, IT, NL)
Memory, Micro-SD, 2 GB, endless data-recording
Warranty
1)
2)
Solar-Log 200
Solar-Log 500
Solar-Log 1000
1
1 x RS485 / RS422
–
15kWp
max. 1000m1)
optional, internal antenna
–
10
1 x RS485 / RS422
–
50kWp
max. 1000m1)
optional, internal antenna
–
100
1 x RS485, 1x RS485 / RS422
●
1MWp
max. 1000m1)
optional, internal antenna
●
●
●
–
●
–
–
●
–
●
●
●
●
●
●
–
●
●
–
●
●
●
●
●
●
●
●
●
●
●
●
●
●
–
●
●
–
–
–
●
●
–
●
●
2-line Dot matrix display
Keypad entry
●/●
●
●
●
●
●
Full - graphic display
via touch screen
●/●
●
–
–
–
–
●
–
–
–
–
●
●
●
●
●
3W
●
●
●
220 V / 12V
3W
-10°C to +50°C
Plastic
22.5 x 4 x 28.5
Wall mounted
IP 20 (only for indoor use)
●
●
●
5 years
3W
●
●
●
Depending on the inverter and the cable length (Figures may vary depending on the type of device)
Other important information on Bluetooth and compatibility can be found on www.solar-log.com
99
Power Supplies
Inverter WRI
Inverter
EFFEKTA® Inverter WRI-Series
NEU / NEW
Description
The new EFFEKTA® WRI-series inverters are suitable
in the low and middle performance range as AC power
supplies for mobile applications.
Features
‧ Output voltage 230VAC
‧ Input voltage 12 or 24VDC
‧ Available with 150, 300, 500, 700, 1000, 2000,
3000, 4000 or 5000Watt
‧ Compact design
‧ Minimal weight
‧ Battery low alarm
‧ Overload-/voltage reversal-/short circuit-safe
‧ Overheat control
100
AC power supplies, mobile inverters
Specifications
Specifications
Model
Max. continuous power (W)
Surge capability (W)
Output voltage
Output frequency
Optimum efficiency (App.)
No load current draw (A)
Input voltage
Low battery alarm
Low battery shutdown
output wave form
No. of AC connections
Temperature
Replaceable fuse (Amps)
Dimensions (H x W x D in mm)
Weight
Model
Max. continuous power (W)
Surge capability (W)
Output voltage
Output frequency
Optimum efficiency (App.)
No load current draw (A)
Input voltage
Low battery alarm
Low battery shutdown
Output wave form
No. of AC connections
Temperature
Replaceable fuse intern (Amps)
Dimensions (H x W x D in mm)
Weight
Model
Max. continuous power (W)
Surge capability (W)
Output voltage
Output frequency
Optimum efficiency (App.)
No load current draw (A) switch „on“
No load current draw (A) switch „off“
Input voltage
Low battery alarm
Low battery shutdown
Output wave form
No. of AC connections
Temperature
Replaceable fuse intern (Amps)
Dimensions (H x W x D in mm)
Weight
WRI-150
150
300
≤0.5
20A
155 x 122 x 51
0.75kg
WRI-700
700
1600
≤1.0
WRI-300
300
600
RMS 230VAC ±10%
50Hz ±4Hz
85%
≤0.5
12Volts (24Volt)
10.5-11.1Volts (20.0-21.0Volts)
9.8-10.4Volt (19.1-19.9Volts)
Regulated modified sine-wave
1
0°C to +40°C
30A
175 x 122 x 51
1.00kg
WRI-3000
2700
3000
≤2.0ADC
≤0.2mADC
2
≥250
470 x 208 x 148
7.5kg
≤0,5
2 x 30A
195 x 170 x 61
1.55kg
WRI-1000
1000
2000
RMS 230VAC ±10%
50Hz ±4Hz
85%
≤1.0
12Volts (24Volts)
10.5-11.1Volts (20.0-21.0Volts)
9.8-10.4Volt (19.1-19.9Volts)
Regulated modified sine-wave
1
≥70
221 x 170 x 61
1.80kg
WRI-500
500
1000
WRI-2000
2000
4000
≤1.5
2
0°C to +40°C
5 x 25A
292 x 170 x 61
2.30kg
WRI-4000
3600
4000
RMS 120/230VAC ±10%
50Hz ±4Hz
90%
≤2.0ADC
≤0.2mADC
12Volts (24Volts)
10.8Volts (21.5Volts)
10Volts (20Volts)
Regulated modified sine-wave
2
0°C to + 40°C
≥350
470 x 208 x 148
10.3kg
6 x 30A
340 x 210 x 80
3.70kg
WRI-5000
4500
5000
≤1.2ADC
≤0.2mADC
2
≥400
630 x 208 x 148
11.5kg
101
Power Supplies
Inverters WRS
Inverters
EFFEKTA® WRS-series
WRS-012-3000
Description
The EFFEKTA® WRS-series inverters are suitable in
the low and middle performance range as AC power
supplies for industrial and mobile applications.
Front view WRS-024-1500
Features
‧
‧
‧
‧
‧
Output voltage 230VAC
Input voltage 12, 24 or 48VDC
Battery low alarm
Overload-/ voltage reversal-/short circuit-safe
Screwable terminals on the rear side
Rear view WRS-024-1500
102
AC power supplies, mobile inverters
WRS-012-0700
WRS-024-0350
Specifications
Specifications
Model
Power
Output voltage
Input voltage
Low.Bat.-Shutdown
Dimensions H x W x D
Weight
WRS-012-0200
WRS-024-0200
WRS-048-0200
200W
200/220/230/240VRMS ±3%, 50/60Hz switchable
24VDC
48VDC
12VDC
10.0VDC
20.0VDC
42.0VDC
71 x 119 x 230mm
1.2kg
Model
Power
Output voltage
Input voltage
Low.Bat.-Shutdown
Dimensions H x W x D
Weight
WRS-012-1500
Model
Power
Output voltage
Input voltage
Low.Bat.-Shutdown
Dimensions H x W x D
Weight
WRS-012-0350
Model
Power
Output voltage
Input voltage
Low.Bat.-Shutdown
Dimensions H x W x D
Weight
WRS-012-2000
Model
Power
Output voltage
Input voltage
Low.Bat.-Shutdown
Dimensions H x W x D
Weight
WRS-012-0700
Model
Power
Output voltage
Input voltage
Low.Bat.-Shutdown
Dimensions H x W x D
Weight
WRS-012-3000
Model
Power
Output voltage
Input voltage
Low.Bat.-Shutdown
Dimensions H x W x D
Weight
WRS-012-1000
WRS-024-0350
WRS-048-0350
350W
200/220/230/240VRMS ±3%, 50/60Hz switchable
24VDC
48VDC
12VDC
10.0VDC
20.0VDC
42.0VDC
71 x 119 x 230mm
1.6kg
WRS-024-0700
WRS-048-0700
700W
200/220/230/240VRMS ±3%, 50/60Hz switchable
24VDC
48VDC
12VDC
10.0VDC
20.0VDC
42.0VDC
81 x 179 x 298mm
2.8kg
WRS-024-1500
WRS-048-1500
1500W
200/220/230/240VRMS ±3%, 50/60Hz switchable
24VDC
48VDC
12VDC
10.0VDC
20.0VDC
42.0VDC
102 x 278 x 413mm
7.2kg
WRS-024-2000
WRS-048-2000
2000W
200/220/230/240VRMS ±3%, 50/60Hz switchable
24VDC
48VDC
12VDC
10.0VDC
20.0VDC
42.0VDC
102 x 278 x 413mm
7.2kg
WRS-024-3000
WRS-048-3000
3000W
200/220/230/240VRMS ±3%, 50/60Hz switchable
24VDC
48VDC
12VDC
10.0VDC
20.0VDC
42.0VDC
102 x 283 x 455mm
10.6kg
WRS-024-1000
WRS-048-1000
1000W
200/220/230/240VRMS ±3%, 50/60Hz switchable
24VDC
48VDC
12VDC
10.0VDC
20.0VDC
42.0VDC
81 x 179 x 334mm
3.8kg
103
Power Supplies
Special DC appliances
Special
appliances
“Powermanager“
Processor-regulated uninterruptible power supply
system with 230V/50Hz/200VA AC output, five separate
24V/20A DC-outputs, battery monitoring, protection
monitoring, watch-dog, in accordance with VDE0828/
EN60849.
Production-redundant
Telecom power supply 48V/1800A
48V/2.7kW/55A charging rectifiers makes up a parallelredundant UPS system with two maintenance-free
48V/1000Ah batteries, 1800A inverter with central
installation control, low-discharging protection and
SNMP-interface.
Reference projects:
Waste incinerator in Bremen (ANO II)
GEW Köln tetra radio network
M”Net München
broadnet mediascape AG
VOITH Hydro Power
104
Special appliances
Product
Application
Features
MD-1
Constructed for industrial systems
Online double-conversion with integrated auto bypass
Mounting height 4U, to achieve a shortened modular
depth of 300mm.
All power lines, outputs and sockets for control signal
(floating contacts) on hardwired Phoenix terminals.
Basic unit
Optimised for 19“ switch cabinet
MH RM 2000
®
EFFEKTA UPSs are not only suited for use in computers,
but also for all sensitive, power-dependent units.
We have a solution for every kind of application. We
are also experienced in custom designs and small
production runs.
All models are available in standard enclosures or ac be
supplied for switchboards or DIN rails.
Product
Application
GSV („Gesicherte Stromversorgung“ [german])
The GSV is intended to provide the needed power to electric
drive units for doors during powerfailures in emergency
situations.
Features
The GSV provides up to 72 h standby mode and after that about
5 min with 500 W load. The system can be activated by an
external dry contact.
During a powerfailure after a delay (10 seconds default) a signal
switch (500 ms impulse) will be sent to activate the electric drive
unit.
Back in normal mode the mains will be switched directly to the
output.
In normal mode the GSV-system is charging the internal batteries and in emergency mode it monitores the battery voltage.
Basic unit
In- and output single phase hardwired
Capacity 1000VA/670W (maximum 4,3 A)
Cabinet prepared for wall assembly
Electronics: IP65
Batteries: IP21
Dimensions (compl. HxWxD) 500x300x120 mm
MT 1000
105
Power Supplies
Service
Service
Overview of maintenance and service contracts
1) Performance-based service
. Date: as customer requires
. Cleaning the installation
. Check-up of the mechanical condition
and all installation parts
. Voltage check of AC current
.
.
inter-circle
Control and possible alignment of oscillator circles
Examination and adjustment of all electric
control circuits of inverter and rectifier
. Control measurement of thyristors, diodes,
.
.
.
transformers, filter-elements etc, to guarantee
a perfect operation of installation
Capacity test of the batteries as customor requires
Exchange of defective batteries after prior
approval of cost estimate
Invoice: at the valid EFFEKTA® cost rate
2) Partial-maintenance contract including spare
parts excluding batteries
. Date: 1x annually
. Cleaning the installation
. Check-up of the mechanical condition
.
.
. Examination and adjustment of all electric
control circuits of inverter and rectifier
. Control measurement of thyristors, diodes,
.
.
.
.
.
.
.
106
and all installation parts
Voltage check of AC current
inter-circle
Control and possible alignment of oscillator circles
transformers, filter elements etc, to guarantee
a perfect operation of installation
Capacity test of the batteries as customor requires
Exchange of defective batteries after prior
approval of cost estimate
Fault hotline
(response time: 24 hours Mon-Fri 8am- 5pm)
Spare parts covered by maintenance fee
15% discount on batteries
Minimum contract period: 4 years
Invoice: via maintenance fee
Service
3) Full maintenance contract including
spare parts and batteries
. Date: 1x annually
. Cleaning the installation
. Check-up of the mechanical condition
.
.
.
and all installation parts
Voltage check of AC current inter-circle
Control and possible adjustment of oscillator-circles
Examination and attitude of all electric
control circuits of inverter and rectifier
. Control measurement of thyristors, diodes,
.
.
.
.
.
.
transformers, filter elements etc, to guarantee
a perfect operation of installation
Capacity test of the batteries as customor requires
Exchange of defective batteries
Fault hotline
(response time: 24 hours Mon-Fri 8am- 5pm)
Spare parts and batteries via maintenance fee
Minimum contract period: 4 years
Invoice: via maintenance fee
107
Power Supplies
Reference
Reference
Industry:
Sports facilities:
· Alstom Turbinen........................................Nuremberg
· BASF AG ..................................................Ludwigshafen
· BASF AG ..................................................Willstätt
· Bayer Leverkusen ....................................Leverkusen
· Bayer Vital ................................................Fernwald
· BMW AG...................................................Munich
· Bombardier ...............................................Braunschweig
· Burda Rechenzentrum .............................Munich
· Daimler Chrysler.......................................Stuttgart
· Daimler Chrysler.......................................Rastatt
· Deutsche Messe AG.................................Hannover
· Deutscher Wetterdienst ............................Offenbach
· Festo ........................................................Esslingen
· Georg Fischer...........................................Singen
· Gerolsteiner Brunnen GmbH ....................Gerolstein
· Hoechst AG ..............................................Frankfurt
· Hoechst AG ..............................................Wiesbaden
· Höft und Wessel AG .................................Hanover
· Kaufhof .....................................................Cologne
· Klöckner Stahl GmbH ...............................Bremen
· Mattson.....................................................Plietzhausen
· Mediamarkt...............................................Velbert
· Merck KG aA ............................................Grafing
· Mitropa .....................................................Berlin
· Obi ............................................................Martinsried
· Ravensburger Spiele GmbH ....................Ravensburg
· Scheidt & Bachmann ................................Mönchengladbach
· TNT ..........................................................Troisdorf
· VW............................................................Wolfsburg
· Walter AG .................................................Tübingen
· Bayarena ..................................................Leverkusen
· Nürburgring ..............................................Nürburg
· Stadion der Freundschaft .........................Cottbus
· SAP Arena ................................................Mannheim
· Mercedes Benz Arena ..............................Stuttgart
Banks:
· BHF Bank .................................................Frankfurt
· Kreissparkasse .........................................Friedrichshafen
· Sparkasse ................................................Dillenburg
· Volksbank .................................................Altshausen
· Volksbank .................................................Biberach
· Volksbank .................................................Dreieich
· Volksbank .................................................Friedrichshafen
· Volksbank .................................................Gardeling
· Volksbank .................................................Saulgau
· Volksbank .................................................Tettnang
· Volksbank .................................................Weingarten
· Volksbank .................................................Donaueschingen
108
Universities:
· Universität ................................................Heidelberg
· Universität ................................................Wuppertal
· Universität ................................................Ulm
· Universität ................................................Konstanz
· Universität ................................................Tübingen
· Universität ................................................Regensburg
· Universität der Bundeswehr .....................Hamburg
· Universität Gesamthochschule.................Soest
· Fachhochschule .......................................Frankfurt
· Fachhochschule .......................................Stuttgart
· Fachhochschule .......................................Mannheim
· Fachhochschule .......................................Dortmund
· Fachhochschule .......................................Darmstadt
· Fachhochschule .......................................Giessen
Hospitals:
· Albklinik ....................................................Münsingen
· Bundeswehrkrankenhaus .........................Amberg
· Kliniken Landkreis ....................................Sigmaringen
· Krankenhaus St. Martin ............................Duderstadt
· Krankenhaus Bad Cannstatt ....................Stuttgart
· Krankenhaus Stadt Chemnitz...................Chemnitz
· Krankenhaus Sachsenhausen .................Frankfurt
· Städtisches Krankenhaus ........................Friedrichshafen
· Städtisches Krankenhaus.........................Dresden
Reference
Authorities:
EFFEKTA Austria:
· Berliner Verkehrsbetriebe (BVG) .............Berlin
· Abfallbehandlung Nord .............................Bremen
· AOK Brandenburg ....................................Potsdam
· Ambassy of the United Arab Emirates ......Berlin
· Finanzamt.................................................Schweinfurt
· FTZ ...........................................................Eschborn
· Kläranlage ................................................Griesheim
· Kläranlage ................................................Langenhagen
· Kreisverwaltung ........................................Mansfeld
· Landesvermessung ..................................Dresden
· Landesvermessung ..................................Potsdam
· Landeswohlfahrtsverband ........................Kassel
· Landratsamt .............................................Friedrichshafen
· Landratsamt .............................................Mosbach
· Max-Planck-Institut ...................................Golm
· Max-Planck-Institut ...................................Stuttgart
· Messe AG .................................................Hanover
· Polizeipräsidium .......................................Wiesbaden
· Sancura BKK ............................................Wetzlar
· Stadtverwaltung........................................Frankfurt
· Stadtverwaltung........................................Halle
· Stadtverwaltung........................................Konstanz
· Stadtverwaltung........................................Schwalbach
· AGIP Austria GmbH .................................... Wien
· Agrana Fruit Austria GmbH ......................... Allhartsberg
· Allgemein österr. Bezirkskrankenhaus ........ St. Johann in Tirol
· AUVA........................................................... Wien
· Bezirksgericht Kirchdorf .............................. Kirchdorf
· Bob- und Rodlbahn ..................................... Igls
· BTV AG ....................................................... Innsbruck
· Bundesministerium für Justiz ...................... Wien
· Daily Service Tiefkühllogistik GmbH ........... Asten
· Dornbirner Messe GmbH ............................ Dornbirn
· Ebewe Pharma GesmH............................... Unterach am Attersee
· Energie Control GmbH ................................ Wien
· Erber AG ..................................................... Herzogenburg
· Fiber Cable Technologie ............................. Gmünd
· Gartner KG .................................................. Lambach
· Haidlmaier GmbH ........................................ Nussbach
· Hit FM Privatradio........................................ Krems / St. Pölten
· Hypo Bank ................................................... Wien
· IGM Robotersysteme .................................. Wien
· Interwetten AG ............................................ Wien
· Isovolta AG .................................................. Werndorf / Lebring
· Kirchdorfer Zementwerk Hofmann GmbH ... Kirchdorf
· Kraft Foods Österreich GmbH ..................... Wien
· Landessicherheitszentrale Burgenland ....... Eisenstadt
· Landhaus 2.................................................. Innsbruck
· Manpower GmbH ........................................ Wien
· Net4You Internet GmbH .............................. Villach
Telecommunications:
· Broadnet Mediascape ..............................Hamburg
· DeTe Mobil AG .........................................Bonn
· Deutsche Telekom AG ..............................Weilheim
· T-Mobile....................................................Leipzig
· M“net GmbH ............................................Munich
· SCALTEL AG ............................................Waltenhofen
· TeleData GmbH ........................................Friedrichshafen
International:
· Praktiker .......................................................Hungary
· Messer Hungarogaz .....................................Hungary
· Osram...........................................................China
· Philips ...........................................................Israel
· Euroforum Trade Center...............................Luxembourg
· Patentamt .....................................................Vienna/Austria
· Deutsche Babcock .......................................United Arab. Emirates
· Deutsche Botschaft ......................................Nairobi
· Olympiahalle.................................................Innsbruck/Austria
· Migros Markt.................................................Zürich/Switzerland
· Zollamt..........................................................Zürich/Switzerland
· Several in Riga/Latvia, Hungary, Switzerland, Spain, UK,
Sweden, USA, Saudi Arabia, China, Taiwan
109
Power Supplies
Terms & Conditions
Terms
& Conditions
Terms and conditions for sales and delivery of EFFEKTA Regeltechnik GmbH, Rottweil
Preamble
The following terms and conditions for sales and delivery form the basis of the delivery and service contracts of the contractor (user) and
supplement the applicable law.
They are only applicable to businesses where the contract is made in the course of their business, legal entities of the public law or special
authorities under public law.
I. Application
1. Orders only become binding with regard to the type and scope of deliveries after the supplier confirms the order. Any changes and
additions must be in writing.
2. Where ongoing business relationships subsist, these terms and conditions also apply to future transactions even where they are not
expressly communicated to the orderer. The terms and conditions are deemed to be accepted at the latest when the order is placed or
the delivery or service is accepted. If alternative provisions of the orderer or supplier are to apply instead of these terms and conditions,
these must be expressly agreed by the partners.
3. Contrary or divergent sales terms of the orderer shall only be binding on the supplier if they have been expressly acknowledged by
him in writing.
II. Prices
1. A binding price shall only be deemed to have been set after the supplier confirms the order in writing. This is subject to the proviso
that the order details on which the order confirmation is based remain unchanged. The supplier’s prices are in EUR exclusive of any VAT
applicable at the time of the delivery, unless other information is specified.
2. If, in the course of a delivery period of more than four months, a change to the price basis occurs (increase in the price of raw materials,
change of salary and wage rates), the supplier reserves the right to adjust the price accordingly.
3. Packaging, postage and other shipping costs are not included and will be invoiced additionally.
4. The orderer shall bear the costs of any changes to the product he requests after the order has been confirmed.
5. Partial deliveries may be invoiced separately.
1. All payments must be made in Euros exclusively to the supplier.
2. Insofar as nothing else has been agreed, the purchase price must be paid via cash on delivery or advance cheque. In the latter case
delivery shall proceed once the cheque has cleared. In exceptional cases payment terms of 14 days strictly net may apply.
3. If the orderer defaults on payment, the supplier is permitted to demand default interest at eight percentage points above the base
interest rate. The supplier may at any time produce evidence of higher interest damages and charge for these.
4. Failure to observe the terms of payment, default or circumstances that pose a risk of reducing the orderer’s creditworthiness will result
in all of the supplier’s claims becoming due for payment immediately. Further, the supplier is permitted after a reasonable grace period to
withdraw from the contract or demand damages instead of performance.
5. The orderer may only exercise offsetting rights if his counterclaims have been legally established, are indisputable or have been
acknowledged by the supplier.
6. The orderer is permitted to exercise a right of retention insofar as his counterclaim is based on the same contractual relationship.
7. The supplier is under no obligation whatever to accept cheques and bills of exchange. Credit of this type is in all cases subject to
redeemability (on account of payment, not on account of performance) and is deemed to be redeemed on the day that redemption value
is available to the supplier. In the case of bills of exchange, any discount on presentation, stamp duty, bank charges and any direct debit
charges shall be passed on by the supplier.
8. The right to pursue any further contractual or statutory claims in the event of default is reserved.
VII. Responsibility for defects
If the orderer fulfils the duty of inspection, notification and rejection required of him in accordance with section 377 of the Commercial
Code, the supplier is liable for defects of the delivery to the following extent:
1. Where the orderer collects the goods from the supplier’s premises, risk passes with transfer of the goods to the orderer. Where the
goods are shipped, risk passes on transfer of the goods to the carrier. Where the goods are delivered, risk passes when the goods leave
the supplier’s premises.
2. In the event of delays to dispatch that are the fault of the orderer, risk passes on communication of readiness for shipping.
3. Insofar as nothing else has been agreed, the supplier shall select the packaging and shipping type to the best of his judgment. Where
requested in writing by the orderer, the goods may be insured against breakage, transport and fire damage at the orderer’s expense.
1. In the event of a not inconsiderable defect of the purchased goods, the supplier may choose either to correct the defect or supply a
defect-free product (supplementary performance). In the event of failure of the supplementary performance, the supplier is authorised to
undertake a further act of supplementary performance. Further, in the event of repeated supplementary performance, the supplier decides
between re-supply or correction of the defect. Should one or both of these methods of supplementary performance be impossible or not
proportionate, the supplier is permitted to refuse them. The supplier may also refuse supplementary performance for such time as the
orderer does not fulfil his payment obligations towards him proportionate to the defect-free part of the performance.
2. If supplementary performance as per clause 1 is impossible or fails, the orderer has the right either to reduce the purchase price
accordingly or withdraw from the contract in accordance with the statutory provisions. These rights are open to the purchaser particularly
where the supplier culpably delays or refuses the supplementary performance or if it fails for a second time. Insofar as the following (clause
4) does not provide otherwise, further claims of the orderer, regardless of their legal ground (in particular claims arising from the breach
of contractual conditions and warranties, reimbursement of expenses with the exception of that provided for in section 439 subsection 2
of the German Civil Code, unlawful acts and other tortious liability) are excluded. This applies in particular to claims for damages beyond
the thing purchased and for claims for the reimbursement of lost profits. This also covers claims that do not result from the defectiveness
of the thing purchased.
3. The above provisions also apply to the delivery of a different item or a lesser quantity.
4. The exclusion of liability under clause 2 does not apply where an exclusion or limitation of liability for damages for death, personal injury
or damage to health caused as a result of a wilful or negligent breach of duty by the user or wilful or negligent breach of duty by a legal
representative or vicarious agent of the user has been agreed. It also does not apply where an exclusion or limitation of liability for other
damages caused as a result of a wilful or negligent breach of duty by the user or wilful or negligent breach of duty by a legal representative
or vicarious agent of the user has been agreed. Liability shall not be excluded where the supplier breaches a fundamental contractual duty
or a “cardinal duty”, but instead limited to the foreseeable damages typical for the type of contract. It is further excluded under clause 2.
The exclusion of liability shall not apply if liability for personal injury or material damage to privately used items in the event of defects to
the thing supplied applies under the Product Liability Act.
Further, this also applies in cases covered by a guarantee by the supplier or where assurances were made as to specific properties of the
goods purchased. Here a defect in this regard triggers the supplier’s liability.
The above applies correspondingly in the event of reimbursement of expenses.
5. Claims for supplementary performance, damages and replacement goods/services are subject to a time limit of one year after delivery
of the goods.
This does not apply to goods which have been deployed in a building in accordance with their standard application and have caused this
to become defective. The time limit here is five years.
Claims for abatement and the exercise of the right to withdraw from the contract are excluded where the time limit for a claim for
supplementary performance has been exceeded.
In the case of clause 3 the purchaser may refuse to pay the purchase price to the extent that he would be entitled in the event of
withdrawal or abatement. In the case of an exclusion of withdrawal and subsequent refusal to pay, the supplier is permitted to withdraw
from the contract.
6. Claims resulting from right of recourse to the producer are not affected by this section.
7. No liability is accepted for damage resulting from unsuitable or improper use, defective installation by the orderer or a third party,
defective or negligent handling or natural wear. Further, the supplier bears no liability for any damages caused by unsuitable equipment,
defective building work, replacement materials, chemical and electrochemical or electrical influences (insofar as these are not the fault of
the supplier) and improper alterations or maintenance work made without prior approval of the manufacturer on the part of the orderer or
third parties. The same applies to unauthorised re-working or improper handling.
8. Transport damages must be reported immediately to the delivering transport company. The carrier’s instructions on subsequent
procedure must be followed in all cases. Never should goods damaged in transit be sent to us either through us or the transport company
without such instructions.
V. Retention of title
VIII. Breaches of duty
1. The supplier shall retain title to the deliveries until all current and future amounts due from the business relationship have been settled,
even where the purchase price of specifically designated amounts due has been paid. In the case of rolling invoices, the retained title of the
deliveries (goods subject to retention of title) counts as a security for the payment of amounts due on the supplier’s account.
2. In the event of conduct constituting a breach of contract on the part of the orderer, in particular late payment, the supplier is entitled
to reclaim the goods. The orderer hereby agrees to the goods being reclaimed under these circumstances. Reclaiming the goods only
represents a withdrawal from the contract where the supplier expressly declares this to be such. Any costs incurred by the supplier in
reclaiming the goods (in particular transport costs) shall be borne by the orderer. Further, the supplier is authorised to prevent the orderer
from selling on or processing the goods subject to retention of title and to revoke any direct debit authorisation that may have been issued.
Once the purchase price and all costs have been paid, the orderer can require any goods reclaimed without an express declaration of
withdrawal to be despatched.
3. The orderer undertakes to handle the goods with care.
4. The orderer may neither mortgage, pledge as security nor assign the goods delivered and corresponding amounts due.
In the case of seizure or other third-party intervention, the orderer shall immediately inform the supplier in writing in order for him to file
a claim in accordance with section 771 of the Civil Procedure Code. Any remaining costs outstanding to the supplier despite successful
litigation as per section 771 of the Civil Procedure Code shall be borne by the orderer.
5. The orderer is permitted to sell on, process or mix the goods in the normal course of business. In doing so he hereby assigns to the
supplier all amounts due from selling on, processing, mixing or other legal grounds (in particular from insurance or non-permitted actions)
to the extent of the final invoice amount agreed with the supplier (incl. VAT).
The orderer remains authorised to collect these amounts due even after assignment, without prejudice to the authorisation of the supplier
to collect the amounts due himself. However, the supplier undertakes not to collect the amounts due for such time as the orderer fulfils his
payment obligations from the revenue received, is not in default of payment and no application to instigate insolvency proceedings has
been made and no suspension of payment is in force.
If this is the case, the orderer is required to notify the supplier on request of the assigned amounts due and debtors, to provide all
information required for collection, to deliver up the associated documents and to notify the debtor (third party) of the assignment.
The direct debit authorisation may be revoked by the supplier in the event of breaches of contract (in particular payment default) by the
orderer.
6. The retention of title also extends to the products arising as a result of processing, mixing or combination of the delivered goods to the
extent of their full value, whereby these processes shall be deemed by the supplier to constitute manufacture. In the event of processing,
mixing or combination of the goods with goods to which a third party retains title, the supplier obtains co-ownership in proportion to the
objective values of these goods.
7. For the purpose of securing the amounts due against the supplier, the orderer also assigns to the supplier the amounts due which arise
in favour of a third party through the combination of the delivered goods with land.
8. The securities owing to the supplier are not included where the value of his securities exceeds the value of the secured claims by
more than 30%.
9. The enforceability of the retention of title in the event of default on payment or exposure to loss and seizure of the delivered goods by
the supplier represents withdrawal from the contract.
1. The supplier’s liability for breach of duty is limited to grossly negligent or wilful breaches of duty.
2. Any liability for the infringement of intellectual property rights of third parties is excluded, in particular when performing production
tasks in accordance with the orderer’s specifications. The supplier is not subject to a duty of scrutiny in regard to the intellectual property
rights of third parties.
III. Delivery quantity, delivery period
1. Production-related over- or underdeliveries of up to 10% of the order quantity are permitted.
2. The supplier is permitted to make partial deliveries.
3. The delivery periods commence with the date of order confirmation by EFFEKTA - Regeltechnik GmbH. The delivery periods specified
by the supplier refer to the shipping date of the goods. They shall be deemed to have been observed if at this time the goods are
dispatched from the factory or the orderer is informed that they are ready to be shipped.
4. The agreed delivery time is only applicable after all technical and commercial details have been settled.
Accordingly, all delivery times are provisional. Delivery times are only binding where they have been confirmed to the orderer as such
in writing.
5. If action on the part of the orderer is necessary for the manufacture of an item or the execution of a delivery, the delivery period shall not
commence until the orderer has fully completed this action.
6. In the event of a delay in delivery, the orderer may withdraw from the contract should a reasonable grace period expire without results. In
the event of impossibility of performance on the part of the supplier, this right is available without the supplementary period.
Delay in delivery is deemed to amount to impossibility if delivery does not occur for more than one month.
Claims for damages (incl. any consequential loss) are excluded, without prejudice to clause 7; the same applies to reimbursement of
expenses.
7. The exclusion of liability regulated by clause 6 shall not apply where an exclusion or limitation of liability for damages for death,
personal injury or damage to health resulting from a wilful or negligent breach of duty by the user or vicarious agents of the supplier has
been agreed; further, it shall not apply where an exclusion or limitation of liability for other loss resulting from a wilful or grossly negligent
breach of duty by the supplier or a wilful or grossly negligent breach of duty by a legal representative or a vicarious agent of the supplier
has been agreed.
Liability shall not be excluded where the supplier culpably breaches a fundamental contractual duty or a “cardinal duty”, but instead limited
to the foreseeable damages typical for the type of contract.
The above applies correspondingly in the event of reimbursement of expenses.
8. The limitations of liability stipulated in clauses 6 and 7 do not apply insofar as a commercial firm deal was agreed; the same also applies
where the orderer can assert that he no longer has an interest in fulfilling the contract due to a delay for which the supplier is at fault.
9. In the event of forces majeures experienced by the supplier or his subsuppliers, the delivery time shall be prolonged by a corresponding
amount. This shall also apply in the event of intervention by official bodies, difficulties with the supply of energy and raw materials, strikes,
lockouts and unforeseen obstacles to delivery, insofar as these are not the fault of the supplier. The supplier shall inform the orderer of
any such event without delay.
IV. Transfer of risk, packaging and shipping
110
VI. Terms of payment
IX. Software
Insofar as programs are part of the scope of delivery, the orderer obtains individual unlimited usage rights, that is he may not copy them or
use them for any other purpose. Multiple usage rights shall be subject to written agreement. In the event of an infringement of these usage
rights, the purchaser shall be liable for the full extent of any resultant loss.
X. Place of performance, jurisdiction and applicable law
1. The place of performance is Rottweil.
2. The court of jurisdiction is Rottweil, insofar as the orderer is trading in the course of a business. The supplier is permitted to bring an
action against the orderer in other permissible jurisdictions.
3. The law of the Federal Republic of Germany applies with regard to all claims and rights resulting from this contract. The application of
UN sale of goods law (CISG) is expressly excluded.
XI. Closing provisions
1. Any changes to the contract or supplementary agreements are only effective if they have been approved in writing by the supplier.
2. Rights of the orderer arising from the legal transaction with the supplier are not transferable.
3. Should any individual provisions of these terms and conditions become partially or wholly ineffective or invalid, this shall not affect the
validity of the remaining provisions. The parties to the contract undertake to agree to a ruling by means of which the purpose intended by
the ineffective or invalid provision is largely achieved.
(As of: November 2006)
Notes
111
Power Supplies
Notes
112
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement