Code Master 2 HID Catalog May 2016
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
Applications
• UL Listed for Marine Type Electric Fixtures Outside Type (Salt
Water).
• Ideal in Class I, Division 1 and 2 installations in refineries, in
pipeline transportation facilities, at drilling rigs and in production
facilities on land and marine platforms.
• Class I, Division 1 areas include:
(1) enclosed derricks, mud tanks, desander-desilter, gasoperated control devices, oil-gas separation vessels, shale
shakers and flowing or beam wells
(2) flowing or beam wells in open areas with cellar or below
grade sump
(3) on refinery docks where tankers are loaded with hoses or
loading arms
(4) in compressor buildings (open or enclosed) where methane
gas is present
• Virtually all enclosed areas at drilling operations or refineries
where ventilation is inadequate, or where a cellar or below grade
sump exists, are Class I, Division 1.
Shown with Optional High Bay Reflector
Features
• Choice of mountings: (1) crossarm with degree indicator; (2)
junction box for horizontal or vertical mount; and (3) swivel for
pole mount (screws onto standard 2” pipe threads).
• Fixtures operate safely in high ambient temperatures. For
example, in Class I areas the 150 W HPS unit operateSee page
1290 for classified area suitability.
• Arrangement of heat-producing components results in more
efficient heat dissipation for cooler fixture operation.
• All threaded joints are flame-tight.
• Five threads are always fully engaged in an
explosionproof manner.
• Factory sealed. External seals not required.
• Strategic location of lamp socket, in combination with the
interior prism design of the glass globe, provides optimum light
distribution and control.
• Heat- and impact-resistant globes have smooth
dust-resistant exterior.
• Superior corrosion resistance, with epoxy powder coat finish.
• Ballasts operate at low temperatures – PSMH: -29 °C (-20 °F);
HPS: -40 °C (-40 °F).
Standard Materials
Effective Protected area: 1.8 Square Feet
Options
• Fuses for field installation are ordered by catalog number from
the fuse kit table
• Quartz Auxiliary Emergency Lamp for PSMH and HPS fixtures.
Relay switch installed fixture. Add suffix -E to fixture catalog
number.
• Hot Restrike Option available for 150 W HPS. Add suffix -R.
• Smart Starter. Add suffix -S
NEC/CEC Certifications and Compliances
•
•
•
•
UL Standard: UL 1598, UL 844
UL Listed: E10794
CSA Standard: C22.2 No. 250, C22.2 No. 137
CSA Certified: 025428
• Ballast housing, guard and junction box, and pole mounts:
copperfree (4/10 of 1% max.) aluminum
• Crossarm mount: malleable iron
• Trunnion: steel.
• High bay reflector: aluminum
• Standard dome, deep dome and 30° angle reflectors:
fiberglass reinforced polyester
• Socket: porcelain
• Screw shell: nickel-plated phosphor bronze
Standard Finishes
• Ballast housing, guard, trunnion and mounting accessories:
epoxy-clad finish. Powder coat baked finish, electrostatically
applied for complete, uniform corrosion protection
414
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2016
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Classified Area Suitability — Suitability includes use of reflector
Lamp
Type
Pulse Start
Metal Halide
Metal Halide 
Supply Wire
°C (°F)
Ambient Temp
°C (°F)
150
50 (122)
40 (104)
T5
C,D
Class II, Division 1 and 2
With Globe or with Globe and
Reflector CEC Temp. Ident. No.
Nameplate
CEC
Marking
Groups
B, C, D
T3A
E,F
150
75 (167)
55 (131)
—
C,D
B, C, D
T3
—
250
75 (167)
40 (104)
T4
C,D
B, C, D
—
—
250
75 (167)
55 (131)
—
C,D
B, C, D
—
—
400
85 (185)
40 (104)
T3A
C,D
B, C, D
—
—
175
75 (167)
40 (104)
T3B
C,D
B, C, D
T3C
E,F,G
250
75 (167)
40 (104)
T3B
C,D
B, C, D
T3A
E,F
320
75 (167)
40 (104)
T3
C,D
B, C, D
—
—
350
75 (167)
40 (104)
T3
C,D
B, C, D
—
—
400
75 (167)
40 (104)
T3
C,D
B, C, D
—
—
175
75 (167)
40 (104)
T4
—
B, C, D
T3C
E, F, G
250
75 (167)
40 (104)
T4
—
B, C, D
T3A
E, F
400
75 (167)
40 (104)
T3C
—
B, C, D
—
—
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
High Pressure
Sodium
Lamp
Watts
Class I, Division 1 and 2 With Globe or with
Globe and Reflector UL/NEC/CEC Temp. Ident. No.
Nameplate
NEC
CEC
Marking
Groups
Groups
 Mercury vapor and metal halide luminaires are not available for purchase within the United States. Please check with your countries governing legislation
regarding allowable lamp types before ordering.
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2016
415
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
Lamp
Watts
ANSI Lamp Type
HPS
PSMH
Catalog Number 
HPS
PSMH
Fixture Unit
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
CFL150MT
—
CFL250MT
—
—
CFL400MT
CFP150MT
CFP175MT
CFP250MT
CFP320MT
CFP350MT
CFP400MT
CFL150JBMT
—
CFL250JBMT
—
—
CFL400JBMT
CFP150JBMT
CFP175JBMT
CFP250JBMT
CFP320JBMT
CFP350JBMT
CFP400JBMT
Fixture Unit with Junction Box for Horizontal or Vertical Mounting 
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30”
Flexible Coupling connects to 3/4” fixture hub and to 1/2”
junction box opening. Furnished with one 3/4” Close-up Plug.
Has Locking Screw for horizontal adjustment.
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) 
2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal
adjustment. 30” Flexible Coupling connects to 3/4” fixture hub
(3/4 – 14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
150
S55
M102
CFL150SFMT
CFP150SFMT
175
—
M137/M152
—
CFP175SFMT
250
S50
M138/M153
CFL250SFMT
CFP250SFMT
320
—
M145
—
CFP320SFMT
350
—
M131
—
CFP350SFMT
400
S51
M135/M155
CFL400SFMT
CFP400SFMT
CFL150CAMT
—
CFL250CAMT
—
—
CFL400CAMT
CFP150CAMT
CFP175CAMT
CFP250CAMT
CFP320CAMT
CFP350CAMT
CFP400CAMT
Fixture Unit with Crossarm Mounting 
For mounting to flat surface. 180° horizontal adjustment with
degree indicator. 30” Flexible Coupling connects to 3/4” fixture
hub (3/4 – 14 NPT) and to any 1/2” opening (1/2 – 14 NPT).
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
 To order fixture with guard, add suffix -G before voltage suffix.
 Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
 Change suffix -MT (120/208/240/277 V) to -480 for 480 V.
416
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2016
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Lamp
Watts
HPS
ANSI Lamp Type
PSMH
MH
HPS
Catalog Number 
PSMH
MH
Fixture Unit
Furnished with Trunnion 3/4” hub. (3/4 – 14 NPT)
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
—
M57/H39
M58/H37
—
—
M59/H33
CFL150TTCN
—
CFL250TTCN
—
—
CFL400TTCN
CFP150TTCN
CFP175TTCN
CFP250TTCN
CFP320TTCN
CFP350TTCN
CFP400TTCN
—
CFH175TTCN
CFH250TTCN
—
—
CFH400TTCN
CFP150JBTTCN
CFP175JBTTCN
CFP250JBTTCN
CFP320JBTTCN
CFP350JBTTCN
CFP400JBTTCN
—
CFH175JBTTCN
CFH250JBTTCN
—
—
CFH400JBTTCN
Fixture Unit with Junction Box for Horizontal or Vertical Mounting 
3/4” fixture hub and two conduit openings (3/4 – 14 NPT). 30” Flexible
Coupling connects to 3/4” fixture hub and to 1/2” junction box
opening. Furnished with one 3/4” Close-up Plug. Has Locking Screw
for horizontal adjustment.
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
—
M57/H39
M58/H37
—
—
M59/H33
CFL150JBTTCN
—
CFL250JBTTCN
—
—
CFL400JBTTCN
Fixture Unit with Pole-Top Mount (on 2” Threaded Pipe) 
2” tapered threads (2 – 11-1/2 NPT). Locking Screw for horizontal
adjustment. 30” Flexible Coupling connects to 3/4” fixture hub (3/4 –
14 NPT) and to 1/2” pole-top opening (1/2-14 NPT).
CFL150SFTTCN
CFP150SFTTCN
150
S55
M102
—
175
—
M137/M152
M57/H39
250
S50
M138/M153
M58/H37
320
—
M145
—
—
CFP320SFTTCN
—
350
—
M131
—
—
CFP350SFTTCN
—
400
S51
M135/M155
M59/H33
—
CFL250SFTTCN
CFL400SFTTCN
—
CFP175SFTTCN
CFH175SFTTCN
CFP250SFTTCN
CFH250SFTTCN
CFP400SFTTCN
CFH400SFTTCN
CFP150CATTCN
CFP175CATTCN
CFP250CATTCN
CFP320CATTCN
CFP350CATTCN
CFP400CATTCN
—
CFH175CATTCN
CFH250CATTCN
—
—
CFH400CATTCN
Fixture Unit with Crossarm Mounting 
For mounting to flat surface. 180° horizontal adjustment with degree
indicator. 30” Flexible Coupling connects to 3/4” fixture hub (3/4 – 14
NPT) and to any 1/2” opening (1/2 – 14 NPT).
150
175
250
320
350
400
S55
—
S50
—
—
S51
M102
M137/M152
M138/M153
M145
M131
M135/M155
—
M57/H39
M58/H37
—
—
M59/H33
CFL150CATTCN
—
CFL250CATTCN
—
—
CFL400CATTCN
 To order fixture with guard, add suffix -G before voltage suffix.
 Fixtures furnished with trunnion and bolts, flexible coupling and fittings, and mounting accessory. The trunnion provides vertical adjustment and the mounting
accessory provides horizontal adjustment.
 Change voltage suffix -TT (120/277/347 V) to -MT for 120/208/240/277 V, -C2 for 208 V, -C3 for 240 V, -C6 for 480 V, or -C7 for 600 V.
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2016
417
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
150
175
250
320
350
400
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
Description
Junction Box for Horizontal or Vertical Mounting
Box has 1/2” opening for threading to Flexible Coupling, and two 3/4”
conduit openings (3/4 – 14NPT) and is furnished with one 3/4” close-up
plug. Locking screw for horizontal adjustment. Trunnion bolts furnished.
Aluminum, gray epoxy finish.
Catalog Number
AF-JB
Pole-Top Mount (on 2” Threaded Pipe)
Threads onto 2” pipe with tapered threads (2-11 – 1/2 NPT). Includes
floodlight trunnion bolts. Locking screw for horizontal floodlight
adjustment. Aluminum, gray epoxy finish.
AF-SF
Crossarm Mounting Bracket
Has 180° horizontal adjustment – degree-marked. Facilitates mounting
floodlight to crossarm or other flat surface, or to G-AM-8-WB Pole/Wall
Mounting Bracket (see photo below). Includes floodlight trunnion bolts.
Malleable iron, plated, chromate sealed, architectural bronze EPOXY finish.
G-AM-8-CA
Polyester Reflectors – 150 W through 400 W
Standard Dome
CMR-4ST
Deep Dome
30° Angle
CMR-4DD
CMR-4AN
Aluminum High Bay Reflectors – 150 W through 400 W
CMR-4HB
Flexible Coupling – 30” Long
Connects to 3/4” Fixture Unit hub (3/4 – 14 NPT) and to 1/2”
Junction Box or Pole-Top Accessory opening (1/2 – 14 NPT).
AF-EXL
Quartz Emergency Lamp for Pulse Start Metal Halide and High Pressure Sodium Fixtures
Fixtures can be supplied with a socket to accept a 150 W or 250 W, 120 V quartz lamp.
This D.C. bayonet base socket is in addition to the standard lamp socket, independent of the lighting fixture voltage.
Add Suffix-E
HPS Smart Hot Restrike
Smart Hot Restrike will immediately restrike an HPS lamp when power is restored after a momentary power interruption.
The smart function removes the hot restrike ignitor from the circuit if the lamp burns out or is removed from the socket.
Eliminates starter failures caused by prolonged operation with cycling or failing lamps and simplifies finding their location,
reducing maintenance and repair costs.
Optional for 150 W fixtures (HPS only)
Add Suffix -SR
HPS Hot Restrike
Restrikes HPS lamp immediately when power is restored after a momentary power interruption.
Optional for 150 W fixtures (HPS only)
Add Suffix -R
HPS Smart Starter
Smart Starter for HPS and PSMH fixtures. Incorporates a 1-1/2-minute timer and performs as a conventional starter to normally
start lamp. Removes itself from circuit if lamp burns out or is removed from socket. Eliminates starter failures caused by
prolonged operation with cycling or failing lamps and simplifies finding their location, reducing maintenance and repair costs.
Optional for all fixture watts
Add Suffix -S
G-AM-8-CA Crossarm Mounting Bracket
Shown with G-AM-8-WB Pipe/Wall Mounting Bracket.
The G-AM-8-WB bracket is not furnished with fixtures.
418
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2016
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
Lamp
Watts
150
250
320
350
400
Ballast Amps
Pulse Start Metal Halide
Super CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
1.10
1.86
0.75
1.23
0.65
0.98
0.55
0.87
0.25
0.65
0.25
0.50
1.96
2.50
1.13
1.45
0.98
1.25
0.85
1.10
0.62
0.90
0.32
0.67
3.30
3.25
1.90
1.90
1.60
1.65
1.40
1.40
0.70
1.10
0.45
0.85
3.60
3.70
2.10
2.10
1.80
1.80
1.60
1.60
0.70
1.01
0.60
0.90
3.50
4.00
2.00
2.30
1.75
2.00
1.50
1.75
1.10
1.35
0.75
1.00
Metal Halide
CWA
Start
Operating
—
—
—
—
—
—
—
—
—
—
—
—
1.30
1.80
0.75
1.10
0.65
0.90
0.55
0.80
0.50
0.65
—
—
1.20
2.60
0.65
1.50
0.60
1.30
0.50
1.12
0.80
0.90
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.25
4.00
1.90
2.30
1.65
2.00
1.40
1.75
1.20
1.40
—
—
Fuse Kit Catalog Number
Fuse
Quantity
Required
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
1
2
2
1
1
2
HPS
CF-10
CF-5
CF-5
CF-5
CF-5
CF-3
—
—
—
—
—
—
CF-8
CF-5
CF-5
CF-5
CF-5
CF-2
—
—
—
—
—
—
—
—
—
—
—
—
CF-15
CF-8
CF-5
CF-5
CF-5
CF-5
PSMH
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
CF-2
CF-8
CF-5
CF-5
CF-3
CF-3
CF-2
CF-8
CF-6
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
CF-10
CF-8
CF-5
CF-5
CF-5
CF-3
MH 
—
—
—
—
—
—
CF-5
CF-3
CF-3
CF-2
CF-2
—
CF-8
CF-5
CF-5
CF-3
CF-3
—
—
—
—
—
—
—
—
—
—
—
—
—
CF-10
CF-8
CF-5
CF-5
CF-5
—
Fuse Kit includes fuse, fuse holder and necessary hardware for field installation. Mounts easily in ballast body with one screw. Order one fuse for 120 and 277 V,
and 2 fuses for 208, 240 and 480 V. CF-2 = 2 amp; CF-3 = 3 amp; CF-5 = 5 amp; CF-6 = 6 amp; CF-8 = 8 amp; CF-10 = 10 amp
 50 through 150 W HPS have H.P.F. High Reactance ballasts; 250 W and 400 W HPS have CWA ballasts.
 Mercury vapor and metal halide luminaires are not available for purchase within the United States. Please check with your countries governing legislation
regarding allowable lamp types before ordering.
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2016
419
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
175
Volts
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
120
208
240
277
347
480
High Pressure
Sodium 
Start
Operating
2.00
1.66
1.16
0.96
1.00
0.83
0.88
0.75
0.52
0.56
0.50
0.44
—
—
—
—
—
—
—
—
—
—
—
—
1.75
2.70
1.00
1.50
0.85
1.30
0.75
1.15
0.60
0.93
0.40
0.65
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
3.10
3.90
1.80
2.25
1.60
1.95
1.35
1.70
1.00
1.32
0.80
1.00
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Integrally Ballasted. 150 W, 250 W, 400 W HPS; 150 W, 175 W, 250 W, 320 W, 350 W, 400 W PSMH; 175 W, 250 W, 400 W MH. Mogul Base.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Dimensions in Millimeters (Inches)
74.9
(2.95)
82.6
(3.25)
60.5
(2.38)
120.7
(4.75)
120.7
(4.75)
144.8
(5.70)
127
(5.00)
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
143.5
(5.65)
125.5
(4.94)
60.5
(2.38)
925.6
(36.44)
417.6
(16.44)
404.9
(15.94)
292.1
(11.50)
88.9
(3.50)
127
(5.00)
44.5
(1.75)
.3
528.80)
(20
38.1
(1.50)
112.8
(4.44)
330.20)
(13.0
9.4 )
593.60
(2 3.2 )
520.60
(2
127
(5.00)
74.9
(2.95)
473.2
(18.63)
4.8 )
302.00
(1
292.1
(11.5)
50
(20.08
0)
292.1
(11.50)
181.1
(7.13)
1346.2 (53.00)
44.5
(1.75)
88.9
(3.50)
74.7
(2.94)
50.8
(2.00)
330.2
(13.00)
Weights kg (lb)
420
150 W
175 W
250 W
320 W
350 W
400 W
21 (46.30)
21 (46.30)
32 (70.55)
32 (70.55)
32 (70.55)
32 (70.55)
Visit our website at www.emerson.com or contact us at (800) 621-1506.
© May 2016
Code•Master™ 2 HID Factory Sealed Floodlights
Marine (Outside Type). Explosionproof
Typical Footcandle Values for Iso-Footcandle Curves. Data Based on 400 W HPS (50,000 Lumens) Clear Mogul Base Lamps.
NEC:
Class 1, Division 1 and 2, Groups C, D
Marine Type Electric Fixtures
Outside Type (Salt Water)
CEC:
Class I, Division 1 and 2, Groups B, C, D
Class II, Division 1, Groups E, F, G
Class II, Division 2, Groups F, G
Class III
CSA 4X
Photometric Data
400W MH Floodlight at 45° Angle with High Bay Reflector
HID/FLOODLIGHT: NEC/CEC EXPLOSIONPROOF
Distance in terms of mounting height
400 W HPS Floodlight at 45° Angle with High Bay Reflector 
Mounting
Height
(feet)
FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES
A
B
C
D
E
F
G
H
I
Mounting
Height
(feet)
FOOTCANDLE VALUES FOR ISO-FOOTCANDLE CURVES
A
B
C
D
E
F
G
H
I
15
52.52
43.34
31.00
17.05
10.23
4.77
2.43
1.36
0.84
15
33.97
22.10
16.12
9.69
6.40
4.12
2.13
1.13
.67
20
29.54
24.38
17.44
9.59
5.75
2.68
1.37
0.77
0.47
20
19.11
12.43
9.07
5.45
3.60
2.31
1.20
.64
.38
25
18.91
15.60
11.16
6.14
3.68
1.72
0.87
0.49
0.30
25
12.23
7.96
5.80
3.49
2.30
30
13.13
10.84
7.75
4.26
2.56
1.19
0.61
0.34
0.31
30
8.49
5.52
4.03
2.42
1.60
35
9.65
7.96
5.69
3.13
1.88
0.88
0.45
0.25
0.15
35
6.24
4.06
2.96
1.78
1.18
.76
.39
.21
.12
0.12
40
4.78
3.11
2.27
1.36
.90
.58
.30
.16
.10
40
7.39
6.10
4.36
2.40
1.44
0.67
0.34
0.19
45°
1.48
1.03
.77
.41
.24
.53
.28
.17
45°
MH
MH
1.0MH
1.0MH
 For 250 Watt HPS Clear, 30,000 Lumen lamp, multiply all FTC values by 0.60.