toshiba air conditioning

TOSHIBA

AIR

CONDITIONING

Product Guide January 2017

01707 378 670 | ampair.co.uk

Toshiba Air Conditioning Product Guide

Contents

About Us

......................................................02

Indoor - Wall Mounted.......................... 130

Indoor - Ceiling Suspended.................. 134

Indoor - Floor Standing.........................137

RAS Split Systems

....................................07

Range Overview.......................................08

Wall Mounted...........................................10

Bi Flow Floor Standing...........................17

Multi Splits - Outdoor Units................. 18

Multi Splits - Indoor Units.....................20

Multi Splits Combination Tables......... 23

Air Handling & HRV

..................................147

Air to Air with DX Coil.............................148

Fresh Air Intake Units............................ 150

VN Heat Recovery Ventilation Units.. 151

VRF Air Handling Unit Interface...........154

RAV Air Handling Unit Interface.......... 156

RAV Split Systems

.................................... 33

Range Overview.......................................35

Wall Mounted...........................................36

Compact Cassette...................................40

4 Way Cassette........................................43

Slim Ducted..............................................49

Standard Ducted.....................................52

High Static Ducted..................................58

Ceiling Suspended..................................60

Floor Standing Conversions.................66

Twin, Triple & Quad Systems...............70

Applied & Air to Water

........................... 163

CIAT............................................................164

Air Curtains - RAV....................................166

Air Curtains - VRF....................................181

Estia Air to Water....................................184

Controls

....................................................... 195

Toshiba Rewards

......................................207

Reference/Faults

......................................215

VRF

.................................................................81

Outdoor - Overview................................83

Outdoor - Mini SMMS Heat Pump......84

Outdoor - SMMSe Heat Pump............ 85

Outdoor - SHRMi Heat Recovery........95

Indoor - FSU Boxes & Branch Pipes.. 102

Indoor - Overview...................................103

Indoor - Heating/Cooling Capacities..104

Indoor - Cassettes................................... 106

Indoor - Ducted.......................................118

Index

.............................................................224

Where are we?

AMP are located in Welwyn Garden City, Hertfordshire only 20 miles from the M25 (Jct 23) and 3 miles from the A1(M) (Jct 6).

AMP Air Conditioning, Blenheim House

Blenheim Court, Brownfields

Welwyn Garden City

Herts AL7 1AD

ampair.co.uk | 01707 378 670 | [email protected]

1

About Us

An Introduction to AMP Air Conditioning

WE KNOW HOW MUCH YOU RELY ON

US TO PROVIDE THE BEST SOLUTION

FOR YOU SO WE WORK HARD TO

ENSURE THAT WE’RE UNRIVALLED

WHEN IT COMES TO CUSTOMER

SERVICE AND SUPPORT.

Polly McConachie

Company Director & Co-owner

We’ve come a long way since 1989 when we sold our first air conditioning unit from a small office in

Edmonton, North London. Today we’re the UK’s largest independent distributor of HVAC products working from a comprehensive, purpose-built venue in Hertfordshire with multiple warehouse locations throughout the country. We’ve grown significantly over the years by keeping our focus on our customers ensuring we’re exceeding your expectations again and again. In an ever changing business environment, we know you rely on us to do everything we can to support you and your customers.

We also know it’s important for our staff to be trained to the highest levels and so we continue to invest in our staff through professional training and qualifications.

Almost a quarter of AMP’s staff have completed NVQs in Customer Service and Management over the past year and we plan to continue this calendar of ongoing eduction moving forward.

Since the start of 2015 we’ve invested in our company giving you the confidence that we’re the most qualified partner for all your air conditioning needs. Our team recently secured two internationally recognised independent accreditations for environmental and quality management. Our ISO 9001 and 14001 accreditations require us to follow clear, documented procedures for managing our business to consistently achieve high customer satisfaction and minimise environmental impact.

Martin Michaelson

Company Director & Co-owner

@amp_aircon | amp-air-conditioning 2

About Us

Customer Services

Industry Leading Technical Support

We offer an experienced and dedicated pre and post sales technical support team who have many years experience across all Toshiba product ranges. Their expertise encompasses answering the smallest query right through to designing and supporting complex VRF projects. We also have specialist engineers on call to help commission and fault find at a moment’s notice.

Design Services

At AMP we understand that selecting the right equipment for your project is of the utmost importance. With this in mind, our in-house design team is available to provide help with the design of all aspects of your project, whether it’s for a commercial or domestic environment. Our experienced team can review your requirements and apply the most suitable equipment from our portfolio to meet both your needs and budget.

Training

We believe in passing on knowledge and expertise to our customers. Our specially designed Toshiba training courses cover product selection, installation, maintenance and controls. We offer the opportunity of hands-on training giving your engineers the opportunity to experience working systems. Certificates and training guides are offered as part of each course for reference and proof of attendance.

Warranty & After Sales Support

All products supplied by AMP are provided with a comprehensive three year warranty as standard, covering parts and a contribution towards fitting costs*. In the unlikely event that you encounter a problem with a Toshiba system, you can rest assured it will be resolved quickly and efficiently by our professional after sales team.

Extended warranties are available through Toshiba Rewards - see page 207 for more information.

Delivery

We pride ourselves on flexibility of service, offering next day delivery on all orders received up to 3pm the day before. With our main warehouse in Hertfordshire

(just north of London) and benefiting from multiple warehouse storage facilities throughout the UK, we are ideally placed to serve the capital and the rest of the UK quickly and easily. For urgent orders, same day delivery may be available depending on stock availability and delivery location.

Additional services offered by AMP include Grille Colour Matching, Coil Coating,

Bespoke Control Panels, VRF Strip-Down and On-site Engineer visits. Contact your local sales representative or call our customer services team for more information.

*Terms & Conditions apply.

ampair.co.uk | 01707 378 670 | [email protected]

3

About Us

Customer Testimonials

Martin Perkins

R Perkins & Sons

“AMP have been our one stop shop for all things air conditioning since 1989. Quotations, sales, technical information, on site back up and on time delivery. AMP have delivered exceptional service on all levels at all times for the 27 years we have worked together.”

BARRY HAWKES

Hawkes Refrigeration Engineers

“AMP has been a crucial supplier to Hawkes over the last 20 years. We know AMP delivers a first class, professional, competitive and yet personal service to us at Hawkes. Truly an astonishing team of hard working, genuine and knowledgeable people that we will continue to use for all of our air conditioning and heat recovery ventilation requirements.”

DAVID CHAPMAN

Chapman Ventilation

“Being in such a fast-pace and reactive industry, it is important to us to have such a reliable and efficient supplier like AMP. They really understand our needs and are willing to go the extra mile for us. For a number of years they have continued to provide us with good quality service and products.”

PROVIDED A SPECIALIST

SALES ROUTE FOR

OUR PRODUCTS, AS

WELL AS PROVIDING A

FULL PRE-SALES AND

AFTER SALES SUPPORT

FUNCTION ENSURING

OUR CUSTOMERS’

EXPECTATIONS ARE

MET OR EXCEEDED. IN

THE LAST 12 MONTHS

THEY HAVE FURTHER

DEVELOPED THEIR

TEAM BY ADDING KEY

CORE STRENGTHS TO

THEIR STAFF WITH

CONTINUOUS TRAINING

AND ISO QUALIFICATION

TO ENHANCE THE

CUSTOMERS EXPERIENCE.

@amp_aircon | amp-air-conditioning 4

About Us

Sub-Title

“AMP are a pleasure to deal with, very nice people who are always happy to help. AMP are very prompt and fair for the sometimes difficult but very important after-sales service”

Damian Nunn - Pitkin & Ruddock Ltd

Photo: Steve O’Brien, Warehouse Operative at AMP

About Us

Toshiba Rewards

Toshiba’s New Incentive Scheme

Toshiba Rewards is the new incentive scheme from Toshiba.

Launched in January 2016 it builds on the success of the Additions scheme to further reward installers of Toshiba Air Conditioning products.

Reward points are awarded on every purchase of Toshiba products through AMP, these points can then be exchanged for a variety of diff erent rewards.

In addition, simply by registering you will be eligible for an enhanced 5 year warranty, this can be further extended to 7 years, subject to meeting certain criteria.

Exchange rewards points for…

»

Love2Shop gift cards

»

European and Worldwide holidays with Love2Travel

»

Toshiba air conditioning units and accessories

»

Trade installation products

»

Marketing support

To Qualify

»

No minimum turnover

»

One application per company

»

Contractor must adhere to F-Gas

»

Contractor must be Refcom or equivalent compliant

»

Points accumulated on paid invoices

»

Please speak to your sales person who will be happy to assist with your registration details.

See page

207 for further scheme

details

@amp_aircon | amp-air-conditioning 6

RAS Split Systems

RAS Residential

Introduction & Range Overview

Single Split Systems

The Mirai, AvAnt & Daiseikai range of inverter high-wall units has been specifi cally designed for residential applications. The modern design fi ts well into any room. The units are extremely quiet in operation, provide excellent all round comfort and give high energy effi cient heating and cooling. The Mirai range are available in both R410A and R32 at no extra cost. In addition a range of fl oor standing split systems are also available.

Multi Split Systems

When it is necessary to provide a total comfort solution for a multi-room application, Toshiba multi split systems off er the perfect answer for any kind of requirement. One outdoor unit is capable of operating 2, 3, 4 or 5 indoor units.

They are compact and elegant as they are designed to blend in with any room interior. In fact, Toshiba off ers a wide range of possibilities to create all the comfort you desire.

1.5

2.0

Single Split Systems

2.5

Nominal Cooling

3.1

3.5

4.5

5.0

Mirai R410A

Wall Mounted

1Ph (10) 1Ph (10) 1Ph (11) 1Ph (11)

Mirai R32 Wall

Mounted

1Ph (12) 1Ph (12) 1Ph (12) 1Ph (13)

AvAnt Wall

Mounted

Daiseikai Wall

Mounts

Bi Flow Floor

Standing

1Ph (14)

1Ph (15

- 16)

1Ph (17)

1Ph (14)

1Ph (15

- 16)

1Ph (17)

1Ph (13)

1Ph (14)

1Ph (15

- 16)

1Ph (17)

@amp_aircon | amp-air-conditioning 8

RAS Residential

Range Overview

2 - 4.0

2 - 5.2

Multi Split Outdoor Units

Number Of Indoors - Nominal Cooling

3 - 5.2

3 - 7.5

4 - 8.0

1Ph (18) 1Ph (18) 1Ph (18) 1Ph (19)

5 -10.0

1Ph (19) 1Ph (19)

Page numbers in brackets.

Daiseikai Wall

Mounts

2.5

1Ph (20)

Multi Split Indoors

Nominal Cooling

3.5

4.5

1Ph (20) 1Ph (20)

5.0

1Ph (20) 1Ph (20) Wall Mounted 1Ph (20)

Bi Flow Floor

Standing

Compact

Cassette

1Ph (21)

1Ph (21)

Ducted 1Ph (22)

1Ph (21)

1Ph (21)

1Ph (22)

1Ph (21)

1Ph (22)

1Ph (21)

Page numbers in brackets.

ampair.co.uk | 01707 378 670 | [email protected]

9

RAS Residential

Mirai Wall Mounted

R410A

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat) kW kW kW kW

RAS-07BKV-E

Included

RAS-07BAV-E

2.00 (0.65 - 2.50)

1.47 - 1.22

2.50 (0.55 - 3.20)

TBC

5.70 - 4.00

A+ / A+

3.33 - 4.03

TBC

RAS-10BKV-E

Included

RAS-10BAV-E

2.50 (0.67 - 3.10)

1.95 - 1.68

3.20 (0.70 - 3.90)

TBC

5.60 - 4.00

A+ / A+

2.94 - 3.81

TBC

AMBIENT RANGE

Cooling

Heating

°C

°C

46°C to -15°C

24°C to -15°C

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection mm mm kg l/s

Pa dB(A) dB(A) in m m kg mm

293 - 798 - 230

530 - 660 - 240

9.0 - 21.0

68 - 148 n/a n/a

22 - 40

48 - 50

3/8" - 1/4"

15 - 12

15

0.48 - n/a

Yes (3/8” - 1/4” only)

16

293 - 798 - 230

530 - 660 - 240

9.0 - 21.0

70 - 153 n/a n/a

23 - 41

48 - 50

3/8" - 1/4"

15 - 12

15

0.52 - n/a

Yes (3/8” - 1/4” only)

16

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

V-Ph-Hz

A kW

230 - 1 - 50

3 core + E

3.10 - 3.17

0.60 - 0.62

230 - 1 - 50

3 core + E

4.22 - 4.21

0.85 - 0.84

Suggested Fuse Size

Indoor Unit

A

10

£166

10

£169

Outdoor Unit £391 £399

Retail Price £557 £568

Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201 for details |RB-RXS30-E Controller with weekly timer £54

Special price offers available on

Mirai systems

Contact us for details

@amp_aircon | amp-air-conditioning 10

RAS Residential

Mirai Wall Mounted

R410A

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat) kW kW kW kW

RAS-13BKV-E

Included

RAS-13BAV-E

3.10 (0.75 - 3.50)

2.44 - 2.03

3.60 (0.70 - 4.50)

TBC

5.70 - 4.00

A+ / A+

2.70 - 3.75

TBC

RAS-16BKV-E

Included

RAS-16BAV-E

4.40 (1.10 - 4.80)

3.03 - 2.44

5.20 (0.80 - 6.10)

TBC

5.90 - 4.20

A+ / A+

2.82 - 3.42

TBC

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

°C

°C mm mm kg l/s

Pa dB(A) dB(A) in m m kg mm

293 - 798 - 230

530 - 660 - 240

9.0 - 22.0

82 - 172 n/a n/a

24 - 42

48 - 50

3/8" - 1/4"

15 - 12

15

0.58 - n/a

Yes (3/8” - 1/4” only)

16

46°C to -15°C

24°C to -15°C

293 - 798 - 230

530 - 780 - 240

10.0 - 34.0

97 - 210 n/a n/a

26 - 43

49 - 50

1/2" - 1/4"

20 - 12

15

0.96 - 20g/m

Yes (1/2” - 1/4” only)

16

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

V-Ph-Hz

A kW

230 - 1 - 50

3 core + E

5.60 - 4.75

1.15 - 0.96

230 - 1 - 50

3 core + E

7.55 - 7.38

1.56 - 1.52

Suggested Fuse Size

Indoor Unit

A

10

£174

16

£211

Outdoor Unit £458 £662

Retail Price £632 £873

Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201for details |RB-RXS30-E Controller with weekly timer £54

Special price offers available on

Mirai systems

Contact us for details

ampair.co.uk | 01707 378 670 | [email protected]

11

RAS Residential

Mirai Wall Mounted

R32

AMBIENT RANGE

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R32 (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection kW kW kW kW

°C

°C mm mm kg l/s

Pa dB(A) dB(A) in m m kg mm

RAS-05BKVG-E

Included

RAS-05BAVG-E

1.50 (0.66 - 2.00)

1.47 - 1.22

2.00 (0.54 - 3.00)

TBC

5.60 - 4.00

A+ / A+

3.85 - 4.26

TBC

293 - 798 - 230

530 - 660 - 240

9.0 - 21.0

68 - 145 n/a n/a

22 - 37

48 - 50

3/8" - 1/4"

15 - 12

15

0.40- n/a

No

16

RAS-07BKVG-E

Included

RAS-07BAVG-E

2.00 (0.67 - 2.60)

1.95 - 1.57

2.50 (0.55 - 3.30)

TBC

5.60 - 4.00

A+ / A+

3.45 - 3.91

TBC

46°C to -15°C

24°C to -15°C

293 - 798 - 230

530 - 660 - 240

9.0 - 21.0

68 - 148 n/a n/a

23 - 38

48 - 50

3/8" - 1/4"

15 - 12

15

0.40 - n/a

No

16

RAS-10BKVG-E

Included

RAS-10BAVG-E

2.50 (0.68 - 3.00)

2.44 - 1.93

3.20 (0.71 - 3.90)

TBC

5.70 - 4.00

A+ / A+

3.25 - 3.76

TBC

293 - 798 - 230

530 - 660 - 240

9.0 - 21.0

70 - 153 n/a n/a

24 - 39

49 - 51

3/8" - 1/4"

15 - 12

15

0.43 - n/a

No

16

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

V-Ph-Hz

A kW

230 - 1 - 50

3 core + E

2.02 - 2.40

0.39 - 0.47

230 - 1 - 50

3 core + E

2.95 - 3.25

0.58 - 0.64

230 - 1 - 50

3 core + E

3.85 - 3.17

0.77 - 0.85

Suggested Fuse Size

Indoor Unit

A

10

£158

10

£166

10

£169

Outdoor Unit £372 £391 £399

Retail Price £530 £557 £568

Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201 for details |RB-RXS30-E Controller with weekly timer £54

@amp_aircon | amp-air-conditioning 12

RAS Residential

Mirai Wall Mounted

R32

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat) kW kW kW kW

RAS-13BKVG-E

Included

RAS-13BAVG-E

3.30 (0.75 - 3.0)

3.22 - 2.49

3.60 (0.72 - 4.50)

TBC

5.60 - 4.00

A+ / A+

2.92 - 3.75

TBC

RAS-16BKVG-E

Included

RAS-16BAVG-E

4.60 (1.20 - 5.30)

4.49 - 3.36

5.40 (0.93 - 6.40)

TBC

6.20 - 4.20

A++ / A+

3.01 - 3.48

TBC

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R32 (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

°C

°C mm mm kg l/s

Pa dB(A) dB(A) in m m kg mm

293 - 798 - 230

530 - 660 - 240

9.0 - 22.0

82 - 172 n/a n/a

24 - 42

50 - 51

3/8" - 1/4"

15 - 12

15

0.43 - n/a

No

16

46°C to -15°C

24°C to -15°C

293 - 798 - 230

530 - 780 - 240

10.0 - 34.0

97 - 213 n/a n/a

25 - 43

50 - 52

1/2" - 1/4"

20 - 12

15

0.80 - TBC

No

16

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

V-Ph-Hz

A kW

230 - 1 - 50

3 core + E

5.48 - 4.65

1.13 - 0.96

230 - 1 - 50

3 core + E

7.19 - 7.17

1.53 - 1.55

Suggested Fuse Size

Indoor Unit

Outdoor Unit

A

10

£174

£458

16

£211

£662

Retail Price £632 £873

Gravity drain | Rear, top, left or right piping. | For control via GSM or SMS use the Intesis Wi Fi option, see page 201 for details |RB-RXS30-E Controller with weekly timer £54

ampair.co.uk | 01707 378 670 | [email protected]

13

RAS Residential

AvAnt Wall Mounted

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Effi ciency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat) kW kW kW kW

RAS-107SKV-E7

Included

RAS-107SAV-E6

2.5 (1.2 - 3.0)

2.44 - 2.16

3.2 (0.9 - 3.5)

2.05

5.1 - 3.8

A / A

3.25 - 3.81

A / A

RAS-167SKV-E7

Included

RAS-167SAV-E5

4.4 (1.1 - 5.0)

4.30 - 3.37

5.2 (1.0 - 6.2)

3.34

5.8 - 3.8

A+ / A

2.82 - 3.42

C / B

AMBIENT RANGE

Cooling

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airfl ow Rate (l-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff .)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size

Indoor Unit

Outdoor Unit

Retail Price

°C

°C mm mm kg l/s

Pa dB(A) dB(A) in m m kg mm

V-Ph-Hz

A kW

A

275 - 790 - 205

530 - 660 - 240

9 - 28

70 - 158 n/a n/a

28 - 41

48 - 50

3/8" - 1/4"

15 - 8

15

0.63 - n/a

No

VP16 (14id 16od)

230 - 1 - 50

3 core + E

3.88 - 4.19

0.77 - 0.84

10

£179

£421

£600

46°C to -10°C

24°C to -15°C

275 - 790 - 205

550 - 780 - 290

9 - 40

103 - 207 n/a n/a

31 - 45

49 - 50

1/2" - 1/4"

20 - 10

15

1.05 - 20g/m

No

VP16 (14id 16od)

230 - 1 - 50

3 core + E

7.13 - 6.91

1.53 - 1.53

16

£222

£697

£919

Gravity drain | Rear, top, left or right piping | Auto restart | Infrared control only, no hard-wired option |RB-RXS30-E Controller with weekly timer £54.

While

Stocks

Last

@amp_aircon | amp-air-conditioning 14

RAS Residential

Daiseikai 6 Wall Mounted

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size

Indoor Unit

Outdoor Unit

Retail Price

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

A kW

A kW kW kW kW mm

V-Ph-Hz

RAS-B10N3KVP-E

Included

RAS-10N3AVP-E

2.51 (0.80 - 3.50)

2.39 - 2.07

3.21 (0.80 - 5.80)

2.06

8.50 - 4.60

A+++ / A++

5.12 - 4.60

A / A

275 - 790 - 225

630 - 800 - 300

10 - 41

175 - 197 n/a n/a

27 - 43

46 - 47

3/8" - 1/4"

25 - 10

15

1.05 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

2.94

0.49 - 0.63

10

£303

£933

£1,236

RAS-B13N3KVP-E

Included

RAS-13N3AVP-E

3.52 (0.90 - 4.10)

3.35 - 2.77

4.22 (0.80 - 5.90)

2.70

7.00 - 4.50

A++ / A+

4.19 - 4.44

A / A

46°C to -10°C

24°C to -15°C

275 - 790 - 225

630 - 800 - 300

10 - 41

183 - 210 n/a n/a

27 - 44

48 - 50

3/8" - 1/4"

25 - 10

15

1.05 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

4.30

0.84 - 0.95

10

£312

£989

£1,301

RAS-B16N3KVP-E

Included

RAS-16N3AVP-E

4.53 (0.90 - 5.00)

4.31 - 3.37

5.53 (0.80 - 6.70)

3.54

6.60 - 4.30

A++ / A+

3.38 - 3.76

A / A

275 - 790 - 225

630 - 800 - 300

10 - 41

192 - 210 n/a n/a

27 - 45

49 - 50

1/2" - 1/4"

25 - 10

15

1.05 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

6.13

1.34 - 1.47

16

£334

£1,239

£1,573

Gravity drain | Rear, top, left or right piping | Auto restart | Infrared control only, no hard-wired option.

ampair.co.uk | 01707 378 670 | [email protected]

15

RAS Residential

Daiseikai 8 Wall Mounted

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Effi ciency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

AMBIENT RANGE

Cooling

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airfl ow Rate

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff .)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size

Indoor Unit

Outdoor Unit

Retail Price

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

A kW

A kW kW kW kW mm

V-Ph-Hz

RAS-10G2KVP-E

Included

RAS-10G2AVP-E

2.50 (0.55 - 3.50)

2.44 - 2.27

3.20 (0.45 - 5.80)

2.05

9.10 - 5.20

A+++ / A+++

5.15 - 5.52

A / A

293 - 831 - 270

630 - 800 - 300

14 - 42

180 n/a n/a

20 - 42

47

3/8" - 1/4"

25 - 10

15

1.05 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

2.52

0.48 - 0.58

10

£397

£903

£1,300

RAS-13G2KVP-E

Included

RAS-13G2AVP-E

3.50 (0.63 - 4.10)

3.42 - 2.89

4.00 (0.65 - 6.30)

2.56

8.90 - 5.10

A+++ / A+++

4.27 - 5.00

A / A

46°C to -10°C

24°C to -15°C

293 - 831 - 270

630 - 800 - 300

14 - 42

187 n/a n/a

21 - 43

49

3/8" - 1/4"

25 - 10

15

1.05 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

3.57

0.82 - 0.80

10

£407

£959

£1,366

RAS-16G2KVP-E

Included

RAS-16G2AVP-E

4.50 (0.63 - 5.00)

4.40 - 3.36

5.50 (0.65 - 6.80)

3.52

7.30 - 4.60

A++ / A++

3.46 - 4.01

A / A

293 - 831 - 270

630 - 800 - 300

14 - 42

193 n/a n/a

23 - 44

50

1/2" - 1/4"

25 - 10

15

1.05 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

5.96

1.30 - 1.37

16

£425

£1,226

£1,651

Gravity drain | Rear, top, left or right piping | Auto restart | Infrared control only, no hard-wired option.

@amp_aircon | amp-air-conditioning 16

RAS Residential

Bi Flow Floor Standing

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Effi ciency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airfl ow Rate (l-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff .)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size

Indoor Unit

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

RAS-B10UFV-E1

Included

RAS-10N3AV2-E1

2.5 (1.10 - 3.10)

2.44 - 2.03

3.2 (0.90 - 4.80)

2.05

6.60 - 4.10

A++ / A+

4.20 - 4.27

A / A

600 - 700 - 220

550 - 780 - 290

16 - 33

75 - 142 n/a n/ a

26 - 39

46 - 47

3/8" - 1/4"

20 - 10

15

0.80 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

2.90 - 3.51

0.60 - 0.75

10

£537

£518

£1,055

27 - 40

48 - 50

3/8" - 1/4"

20 - 10

15

0.80 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

4.52 - 5.18

1.05 - 1.25

10

£585

£642

£1,227

RAS-B13UFV-E1

Included

RAS-13N3AV2-E1

3.5 (1.10 - 4.10)

3.42 - 2.74

4.2 (1.00 - 5.00)

2.69

6.30 - 4.00

A++ / A

3.33 - 3.36

A / A

46°C to -10°C

24°C to -15°C

600 - 700 - 220

550 - 780 - 290

16 - 34

80 - 153 n/a n/a

RAS-B18UFV-E1

Included

RAS-18N3AV2-E

5.0 (1.00 - 5.70)

4.89 - 3.77

5.8 (1.10 - 6.30)

3.72

5.70 - 3.80

A+ / A

3.01 - 3.21

B / C

600 - 700 - 220

550 - 780 - 290

16 - 39

102 - 18 n/a n/a

34 - 46

49 - 50

1/2" - 1/4"

20 - 10

15

1.40 - 20g/m no

VP16 (14id 16od)

230 - 1 - 50

3 core + E

7.54 - 8.19

1.66 - 1.81

16

£648

£823

£1,471

ampair.co.uk | 01707 378 670 | [email protected]

17

RAS Residential

Multi Split Outdoor Units

Outdoor Unit Model Number

Nominal Cooling (Range)

Nominal Heating (Range)

Number Of Indoor Units

EER - COP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

AMBIENT RANGE

Cooling

Heating

Height

Width

Depth

Weight

Sound Pressure Level (Cool-Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure

Gas Pipe Size*

Liquid Pipe Size*

Maximum Pipe Run (Per Unit)

Maximum Pipe Run (Total)

Maximum Height Difference

Pre-charged for

Charge R410A - Factory

Charge R410A - Additional

Suitable For Replacement Tech.

Power Supply (Outdoor)

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Max Current

Interconnecting Cables

Outdoor Unit

Retail Price

kW

KW

°C

°C mm mm mm kg dB(A) l/s

Pa m m

Kg kW

A m m in in g/m

V-Ph-Hz

A

A

RAS-2M14S3AV-E

4.0 (1.6 - 4.9)

4.4 (1.3 - 5.2)

2

4.82 - 5.18

TBC

-10°C to 46°C

-20°C to 24°C

630

800

300

44

45 - 46

10

1.32

TBC

No

230 - 1 - 50

16

0.93 - 0.89

3.87 - 3.96

12.6

20

30

10

517

0

3/8"

1/4”

3 core + E

£843

£843

RAS-2M18S3AV-E

5.2 (1.7 - 6.2)

5.6 (1.3 - 7.5)

2

3.88 - 4.71

TBC

-10°C to 46°C

-20°C to 24°C

630

800

300

44

47 - 50

585

0

3/8"

1/4”

20

30

10

10

1.32

TBC

No

230 - 1 - 50

16

1.34 - 1.19

6.15 - 5.48

12.6

3 core + E

£927

£927

RAS-3M18S3AV-E

5.2 (2.4 - 6.5)

6.8 (1.9 - 8.0)

2 - 3

4.44 - 4.30

TBC

-10°C to 46°C

-20°C to 24°C

630

800

300

46

47 - 50

605

0

1/2" (A) 3/8" (B-C)

1/4”

25

50

10

15

1.50

TBC

No

230 - 1 - 50

16

1.17 - 1.58

5.39 - 7.22

13.1

3 core + E

£1,314

£1,314

* Pipework size to be as per indoor unit | For performance data when each indoor unit is combined with outdoor unit refer to separate table.

@amp_aircon | amp-air-conditioning 18

RAS Residential

Multi Split Outdoor Units

Outdoor Unit Model Number

Nominal Cooling (Range)

Nominal Heating (Range)

Number Of Indoor Units

EER - COP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Height

Width

Depth

Weight

Sound Pressure Level (Cool-Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure

Gas Pipe Size*

Liquid Pipe Size*

Maximum Pipe Run (Per Unit)

Maximum Pipe Run (Total)

Maximum Height Difference

Pre-charged for

Charge R410A - Factory

Charge R410A - Additional

Suitable For Replacement Tech.

Power Supply (Outdoor)

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Max Current

Interconnecting Cables

Outdoor Unit

Retail Price

kW

KW

°C

°C mm mm mm kg dB(A) l/s

Pa m m in in m m

Kg g/m

V-Ph-Hz

A kW

A

A

RAS-3M26S3AV-E

7.5 (4.1 - 9.0)

9.0 (2.0 - 11.2)

2 - 3

3.75 - 4.09

TBC

-10°C to 46°C

-15°C to 24°C

890

900

320

72

TBC

696

0

1/2" (A-B) 3/8" (C)

1/4”

25

70

15

40

2.40

20

No

230 - 1 - 50

TBC

2.00 - 2.20

9.15 - 10.07

TBC

3 core + E

£1,550

£1,550

RAS-4M27S3AV-E

8.0 (4.2 - 9.3)

9.0 (2.9 - 11.7)

2 - 4

3.50 - 4.67

TBC

-10°C to 46°C

-15°C to 24°C

890

900

320

69

48 - 49

696

0

1/2" (A&B) 3/8" (C&D)

1/4”

25

70

15

40

2.40

20

No

230 - 1 - 50

20

2.29 - 1.93

10.46 - 8.82

16.4

3 core + E

£1,892

£1,892

RAS-5M34S3AV-E

10.0 (3.7 - 11.0)

12.0 (2.7 - 14.0)

2 - 5

3.36 - 4.24

TBC

-10°C to 46°C

-15°C to 24°C

890

900

320

78

TBC

1018

0

1/2" (A&B) 3/8" (C-E)

1/4”

25

80

15

40

2.99

20

No

230 - 1 - 50

TBC

2.98 - 2.83

13.65 - 12.97

TBC

3 core + E

£2,154

£2,154

* Pipework size to be as per indoor unit | For performance data when each indoor unit is combined with outdoor unit refer to separate table.

ampair.co.uk | 01707 378 670 | [email protected]

19

RAS Residential

Multi Split - Indoors

Indoor Unit inc. Infrared Controller

Nominal Cooling

Nominal Heating

Indoor Unit Dimensions (h-w-d)

Indoor Weight

Indoor Unit Airfl ow Rate (Cool - Heat)

Indoor Sound Pressure (l-h)

Pipe Sizes (Gas - Liquid)

Power Supply (Location)

Interconnecting Cables

Indoor Unit

Grille / Spigot Kit

Infra Red Remote Controller

Retail Price

kW kW mm kg l/s dB(A) in

Daiseikai Multi Split High Wall

RAS-B10N3KVP-E

2.5

3.2

RAS-B13N3KVP-E

3.5

4.2

275 - 790 - 225

10

175 - 194

27 - 42

275 - 790 - 225

10

183 - 203

27 - 43

3/8" - 1/4"

Outdoor

3 core + E

£303 n/a

Included

£303

3/8" - 1/4"

Outdoor

3 core + E

£312 n/a

Included

£312

RAS-B16N3KVP-E

4.5

5.2

275 - 790 - 225

10

192 - 208

29 - 45

1/2" - 1/4"

Outdoor

3 core + E

£334 n/a

Included

£334

Gravity drain | Rear, top, left or right piping | Cooling/heating capacities depend on unit combinations & outdoor unit.

Indoor Unit inc. Infrared Controller

Nominal Cooling

Nominal Heating

Indoor Unit Dimensions (h-w-d)

Indoor Weight

Indoor Unit Airfl ow Rate (Cool - Heat)

Indoor Sound Pressure (l-h)

Pipe Sizes (Gas - Liquid)

Power Supply (Location)

Interconnecting Cables

Indoor Unit

Grille / Spigot Kit

Infra Red Remote Controller

Retail Price

kW kW mm kg l/s dB(A) in

Multi Split High Wall

RAS-B10N3KV2-E1 RAS-B13N3KV2-E1

2.5

3.5

3.2

275 - 790 - 225

10

143 - 158

4.2

275 - 790 - 225

10

156 - 175

26 - 38

3/8" - 1/4"

Outdoor

3 core + E

£266 n/a

Included

£266

26 - 39

3/8" - 1/4"

Outdoor

3 core + E

£280 n/a

Included

£280

RAS-B16N3KV2-E1

4.5

5.2

275 - 790 - 225

10

190 - 206

30 - 45

1/2" - 1/4"

Outdoor

3 core + E

£312 n/a

Included

£312

Gravity drain | Rear, top, left or right piping | Cooling/heating capacities depend on unit combinations & outdoor unit.

@amp_aircon | amp-air-conditioning 20

RAS Residential

Multi Split - Indoors

Indoor Unit inc. Infrared Controller

Nominal Cooling kW

Nominal Heating

Indoor Unit Dimensions (h-w-d)

Indoor Weight

Indoor Unit Airflow Rate (Cool - Heat)

Indoor Sound Pressure (l-h)

Pipe Sizes (Gas - Liquid)

Power Supply (Location) kW mm kg l/s dB(A) in

Interconnecting Cables

Indoor Unit

Grille / Spigot Kit

Infra Red Remote Controller

Retail Price

Multi Split Bi Flow Console

RAS-B10UFV-E1

2.5

3.2

RAS-B13UFV-E1

3.5

4.2

600 - 700 - 220

16

130 - 142

23 - 39

600 - 700 - 220

16

142 - 153

24 - 40

3/8" - 1/4"

Outdoor

3 core + E

£537 n/a

Included

£537

3/8" - 1/4"

Outdoor

3 core + E

£585 n/a

Included

£585

RAS-B18UFV-E1

5.0

5.8

600 - 700 - 220

16

167 - 178

31 - 46

1/2" - 1/4"

Outdoor

3 core + E

£648 n/a

Included

£648

Cooling/heating capacities depend on unit combinations & outdoor unit.

Indoor Unit inc. Infrared Controller

Grille / Spigot Kit

Nominal Cooling kW

Nominal Heating kW

Indoor Unit Dimensions (h-w-d)

Indoor Weight

Indoor Unit Airflow Rate (Cool - Heat)

Indoor Sound Pressure (l-h)

Pipe Sizes (Gas - Liquid)

Power Supply (Location)

Interconnecting Cable

Indoor Unit

Grille / Spigot Kit

Infra Red Remote Controller

Retail Price

mm kg l/s dB(A) in

Multi Split 600mm

2

Compact Cassette

RAS-M10SMUV-E RAS-M13SMUV-E

RB-B11MC(W)E

2.7

4.0

268 (27) - 575 (700) -

575 (700)

15 (3)

120 - 152

30 - 37

3/8" - 1/4" outdoor

3 core + E

£679

£216 included

£895

RB-B11MC(W)E

3.7

5.0

268 (27) - 575 (700) -

575 (700)

RAS-M16SMUV-E

RB-B11MC(W)E

4.5

5.2

268 (27) - 575 (700) -

575 (700)

15 (3)

120 - 172

30 - 38

3/8" - 1/4" outdoor

3 core + E

£737

£216 included

£953

15 (3)

125 - 183

31 - 40

1/2" - 1/4" outdoor

3 core + E

£782

£216 included

£998

Cooling/heating capacities depend on unit combinations & outdoor unit.

ampair.co.uk | 01707 378 670 | [email protected]

21

RAS Residential

Multi Split - Indoors

Indoor Unit inc. Infrared Controller

Grille / Spigot Kit

Nominal Cooling kW

Nominal Heating

Indoor Unit Dimensions (h-w-d)

Indoor Weight

Indoor Unit Airflow Rate (Low - High)

Static Pressure

Indoor Sound Pressure (l-h)

Pipe Sizes (Gas - Liquid)

Power Supply (Location) kW mm kg l/s

Pa dB(A) in

Interconnecting Cables

Indoor Unit

Grille / Spigot Kit

Infra Red Remote Controller

Retail Price

RAS-M10G3DV-E n/a

2.7

4.0

210 - 700 - 450

16

106 - 158

35

27 - 35

3/8" - 1/4"

Outdoor

3 core + E

£782 n/a

Included

£782

Multi Split Ducted Indoor Units

RAS-M13G3DV-E n/a

3.7

5.0

210 - 700 - 450

16

107 - 169

35

27 - 37

3/8" - 1/4"

Outdoor

3 core + E

£792 n/a

Included

£792

RAS-M16G3DV-E n/a

4.5

5.5

210 - 900 - 450

19

117 - 217

35

24 - 35

1/2" - 1/4"

Outdoor

3 core + E

£844 n/a

Included

£844

Unit does not come with return air filter

@amp_aircon | amp-air-conditioning 22

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

1 unit

230V

2 units

13

10

13

13

10

13

A

7

7

10

Indoor Unit

7

10

10

13

-

-

7

7

B

-

Power

Supply

230V

Operating

Status

1 unit

2 units

16

7

10

13

16

10

13

A

7

10

13

16

13

16

16

Indoor Unit

7

7

7

-

7

-

-

B

-

10

10

10

13

13

16

Cooling Capacity (kW)

A B

2.00

2.70

-

-

3.70

2.00

2.30

-

2.00

1.70

2.60

2.00

2.31

2.00

1.40

2.00

1.69

2.00

2.60

3.01

3.25

2.60

2.85

2.60

Cooling Capacity (kW)

A B

2.00

2.70

-

-

3.70

4.50

2.00

2.70

3.38

3.60

-

-

2.00

2.00

1.82

1.60

2.60

2.19

1.95

2.60

2.35

2.60

Heating Capacity (kW)

A B

2.00

4.00

-

-

4.40

2.20

2.63

-

2.20

1.77

2.73

2.00

2.30

2.20

1.67

2.00

2.10

2.20

2.80

3.11

3.24

2.80

2.93

2.80

Heating Capacity (kW)

A B

2.70

4.00

-

-

5.00

5.50

2.70

3.34

3.64

3.76

-

-

2.70

2.26

1.96

1.84

2.80

2.49

2.36

2.80

2.67

2.80

ampair.co.uk | 01707 378 670 | [email protected]

23

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V

1 unit

2 units

3 units

-

-

-

-

-

7

7

7

7

-

-

-

-

-

-

-

-

C

-

7

7

7

7

7

10

10

10

10

10

10

13

13

16

7

10

7

7

7

7

7

7

Indoor Unit

B

-

-

-

-

7

10

10

10

13

13

10

10

10

13

13

16

13

16

16

7

10

13

16

10

13

16

10

10

13

A

7

16

7

10

13

16

13

16

10

13

16

13

1.90

2.29

2.54

2.05

2.29

1.74

2.12

2.36

1.90

2.70

3.38

3.60

2.60

3.01

3.25

2.60

2.85

2.60

1.74

2.10

2.50

2.76

Cooling Capacity (kW)

A B C

2.00

2.70

-

-

-

3.70

4.50

2.00

-

-

2.00

-

-

-

2.00

1.82

1.60

2.60

2.19

1.95

2.60

2.35

2.60

1.73

1.55

1.35

1.22

-

-

-

-

-

-

-

-

-

1.73

1.55

1.35

1.22

1.90

1.67

1.53

2.05

1.89

1.73

1.54

1.42

1.90

1.40

1.24

1.13

1.10

1.02

1.73

1.54

1.42

1.40

2.54

2.91

3.07

2.68

2.83

2.26

2.62

2.78

2.43

4.00

4.42

4.56

3.40

3.78

3.94

3.40

3.56

3.40

2.26

2.90

3.26

3.44

Heating Capacity (kW)

A B C

2.70

4.00

-

-

-

5.00

5.50

2.70

-

-

2.70

-

-

-

2.70

2.38

2.24

3.40

3.02

2.86

3.40

3.24

3.40

2.27

1.95

1.77

1.68

-

-

-

-

-

-

-

-

-

2.27

1.95

1.77

1.68

2.54

2.32

2.23

2.68

2.58

2.27

2.09

2.01

2.43

1.72

1.57

1.50

1.44

1.39

2.27

2.09

2.01

1.94

@amp_aircon | amp-air-conditioning 24

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V

1 unit

2 units

3 units

10

10

13

13

16

16

10

10

10

10

13

13

13

13

13

16

16

13

16

16

13

16

16

7

7

7

16

18

10

10

7

7

7

10

10

10

10

7

7

7

7

13

13

13

16

Indoor Unit

B

-

-

-

-

-

16

18

13

16

16

18

10

13

16

18

13

16

18

16

18

16

18

18

16

18

13

16

18

18

18

7

10

13

16

18

10

13

18

10

13

16

18

13

16

18

16

7

10

13

16

10

13

16

18

A

7

10

10

10

10

10

10

7

7

7

7

7

7

7

13

13

13

13

10

10

10

13

16

16

7

7

7

-

-

7

7

7

7

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

C

-

3.03

3.22

2.47

3.01

3.36

3.56

2.71

3.06

3.62

3.81

2.91

3.26

3.46

3.25

2.85

3.03

2.47

2.80

2.98

2.66

2.84

2.50

2.68

3.79

3.60

2.00

2.70

3.56

3.92

4.11

2.70

3.26

2.00

2.70

3.70

4.08

4.50

2.70

3.41

3.94

4.09

3.15

3.73

3.91

3.60

A

Cooling Capacity (kW)

B C

2.00

2.70

-

-

-

3.70

4.50

5.00

-

-

-

-

-

-

2.00

2.00

2.00

1.82

1.80

2.70

2.49

2.36

2.21

3.15

3.07

2.89

3.60

-

-

-

-

-

-

-

-

-

-

-

-

-

3.03

2.90

2.47

2.20

2.02

1.92

2.71

2.51

2.17

2.06

2.91

2.68

2.56

2.40

2.85

2.73

2.47

2.30

2.21

2.66

2.56

2.50

2.41

3.41

3.60

2.00

2.00

1.92

1.74

1.64

2.70

2.38

1.35

1.29

2.47

2.20

2.02

1.92

1.98

1.83

1.61

1.53

1.57

1.45

1.38

1.75

1.71

1.64

2.47

2.30

2.21

2.19

2.10

2.50

2.41

-

-

2.00

2.00

1.92

1.74

1.64

2.00

1.76

3.57

3.76

2.97

3.42

3.63

3.81

3.18

3.38

4.01

4.20

3.50

3.71

3.90

3.56

3.26

3.45

2.97

3.16

3.34

3.09

3.27

3.00

3.18

4.49

4.30

2.70

3.53

4.28

4.49

4.68

3.18

3.80

2.70

4.00

4.81

5.10

5.45

3.60

4.22

4.57

4.74

3.95

4.35

4.53

4.30

Heating Capacity (kW)

A B C

2.70

4.00

-

-

-

5.00

5.50

6.00

-

-

-

-

-

-

2.70

2.70

2.59

2.50

2.45

3.60

3.38

3.33

3.16

3.95

3.95

3.77

4.30

-

-

-

-

-

-

-

-

-

-

-

-

-

3.57

3.45

2.97

2.74

2.64

2.54

3.18

3.07

2.92

2.80

3.50

3.37

3.25

2.97

3.26

3.16

2.97

2.87

2.78

3.09

3.00

3.00

2.91

4.11

4.30

2.70

2.38

2.31

2.20

2.11

3.18

3.04

1.75

1.69

2.97

2.74

2.64

2.54

2.54

2.46

1.97

1.89

1.89

1.82

1.75

2.37

2.37

2.30

2.97

2.87

2.78

2.81

2.73

3.00

2.91

-

-

2.70

2.38

2.31

2.20

2.11

2.14

2.05

ampair.co.uk | 01707 378 670 | [email protected]

25

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V

2 units

3 units

10

10

13

13

13

16

16

16

16

18

10

10

16

16

18

16

18

13

13

13

10

10

10

7

7

10

13

13

13

13

13

13

16

16

10

10

10

10

7

7

18

7

7

7

7

Indoor Unit

B C

7

7 -

-

-

-

-

-

-

-

-

-

-

-

-

-

7

7

-

7

10

10

10

10

10

10

10

7

10

10

7

7

13

13

13

16

10

13

13

13

7

7

7

7

7

7

7

7

7

16

18

13

16

18

16

18

16

18

18

10

13

16

18

18

16

18

13

16

18

16

18

10

13

16

18

13

16

18

13

16

18

16

18

18

7

10

13

10

13

16

18

10

13

A

7

16

18

4.80

1.81

4.28

1.71

2.70

2.70

3.39

2.48

3.77

2.26

3.97

2.14

3.03

3.03

1.59

1.64

3.44

2.83

3.64

2.70

1.53

1.46

1.81

1.71

2.00

1.83

1.67

3.19

3.39

3.19

1.42

3.05

1.36

3.29

3.29

1.32

2.53

2.53

2.53

3.13

2.28

2.28

3.50

3.70

2.10

2.00

2.82

2.82

3.22

2.65

3.42

2.53

3.04

3.04

3.20

2.88

2.10

2.00

2.06

1.93

1.85

1.82

1.73

3.11

3.11

2.60

2.60

2.99

2.46

3.19

2.36

2.80

2.80

2.99

2.69

2.88

2.88

2.63

2.63

1.68

2.60

2.46

2.36

2.30

2.21

2.13

2.63

A

Cooling Capacity (kW)

B C

2.00

2.70

2.00

2.00

-

-

D

-

-

-

3.70

4.08

4.50

2.00

1.82

1.80

-

-

-

-

-

2.70

2.70

3.41

2.49

3.94

2.36

4.09

2.21

-

-

-

-

-

-

-

3.15

3.15

3.73

3.07

3.91

2.89

3.60

3.60

3.79

3.41

3.60

3.60

2.00

2.00

2.70

2.00

3.65

1.97

-

-

-

-

-

-

2.00

2.00

1.97

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

D

-

4.39

4.58

3.18

3.72

3.92

4.11

3.43

3.67

3.85

2.16

2.16

2.06

2.06

3.18

2.14

2.97

2.01

2.85

1.93

2.74

1.85

3.43

1.85

3.33

1.80

3.21

1.73

3.57

3.76

3.57

1.75

3.45

1.69

3.63

3.63

1.63

2.87

2.87

2.87

3.35

2.68

2.68

3.54

2.58

3.73

2.49

3.11

3.11

3.34

3.03

3.56

2.97

3.26

3.26

3.45

3.16

2.58

2.49

2.49

2.43

2.37

2.37

2.30

3.34

3.34

2.93

2.93

3.16

3.34

2.87

2.78

2.23

2.93

2.87

2.78

3.06

3.24

3.14

2.97

3.06

2.97

3.14

2.97

2.78

2.70

2.62

2.97

A

Heating Capacity (kW)

B C D

2.70

2.70

4.00

2.70

-

-

-

4.81

2.59

5.10

2.50

5.45

2.45

-

-

-

-

-

-

3.60

3.60

4.22

3.38

4.57

3.33

4.74

3.16

3.95

3.95

4.35

3.95

4.53

3.77

4.30

4.49

4.30

4.11

4.30

2.70

3.53

4.13

4.30

-

2.70

2.70

2.38

2.38

2.23

2.23

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

@amp_aircon | amp-air-conditioning 26

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V 4 units

10

10

13

13

16

13

16

13

13

13

13

13

16

16

10

10

10

13

13

13

16

16

18

13

13

13

13

13

16

16

10

10

10

10

18

10

10

10

7

7

7

Indoor Unit

B C

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

10

10

10

10

10

10

10

10

10

10

13

13

13

13

13

13

13

10

10

10

10

10

10

10

10

10

13

13

16

18

13

16

16

18

18

13

16

18

13

18

16

18

10

13

18

13

16

18

16

18

18

13

16

13

16

18

16

18

18

10

13

16

10

13

16

18

10

13

A

7

16

18

10

10

10

10

10

10

10

10

10

10

13

7

10

10

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

D

7

A

Cooling Capacity (kW)

B C

1.78

1.78

1.78

D

1.78

2.33

2.90

3.30

3.55

1.72

1.57

1.47

1.42

1.72

1.57

1.47

1.42

1.72

1.57

1.47

1.42

2.18

2.74

3.13

3.38

2.18

2.00

1.88

1.82

1.62

1.48

1.39

1.35

1.62

1.48

1.39

1.35

2.56

2.56

2.91

2.40

3.11

2.30

2.73

2.73

2.93

2.63

2.82

2.82

2.03

2.03

2.60

1.90

2.99

1.79

1.39

1.30

1.24

2.03

1.90

1.79

1.39

1.30

1.24

1.22

1.22

1.17

1.17

1.13

1.13

1.50

1.41

1.33

A

Heating Capacity (kW)

B C D

2.09

2.09

2.80

1.89

2.09

1.89

2.09

1.89

3.30

1.78

3.53

1.73

3.75

1.69

1.78

1.78

1.73

1.73

1.69

1.69

2.58

2.58

3.03

2.43

3.26

2.37

3.47

2.31

2.89

2.89

3.08

2.80

3.26

2.71

2.98

2.98

3.16

2.90

3.07

3.07

2.35

2.35

2.81

2.25

3.02

2.20

1.74

1.74

1.64

1.64

1.60

1.60

1.56

1.56

1.56

1.56

1.51

1.51

1.47

1.47

1.42

1.47

1.47

1.42

1.38

2.35

2.25

2.20

1.38

1.59

1.52

1.48

3.19

1.72

2.42

2.42

2.76

2.27

2.95

2.18

2.59

2.59

2.78

2.50

2.72

2.72

2.23

2.23

2.56

2.10

1.72

1.27

1.76

1.31

1.65

1.22

1.59

1.18

1.56

1.15

1.50

1.11

1.47

1.09

2.93

2.89

2.23

1.21

2.10

1.14

2.51

2.69

3.20

2.66

2.85

3.02

2.77

2.13

2.13

2.66

2.13

2.59

2.07

2.51

2.01

2.77

2.01

2.69

1.96

2.89

1.93

2.51

2.51

2.45

2.45

2.82

3.02

2.28

2.61

2.50

2.80

2.68

2.74

2.03

2.45

2.45

2.03

2.01

2.63

2.37

1.95

1.98

1.98

1.98

2.48

1.81

1.81

1.69

1.69

1.63

1.63

2.28

2.15

2.50

2.07

2.42

2.12

2.47

2.12

2.03

2.65

1.96

2.00

2.00

1.67

1.57

2.12

2.03

1.96

2.00

1.10

2.86

1.09

2.65

2.38

2.38

2.65

2.41

1.29

1.30

1.05

2.81

2.58

2.34

1.27

1.98

2.18

1.81

2.62

2.18

2.09

2.18

2.09

2.18

2.09

1.69

1.63

1.67

1.57

1.50

1.50

1.51

1.51

1.45

1.45

1.55

1.48

1.43

2.00

2.80

2.97

2.47

2.65

2.61

2.34

2.54

2.70

2.25

2.03

1.98

2.47

2.41

2.61

2.81

2.34

2.77

2.54

2.34

2.31

2.25

2.25

2.03

1.98

1.98

1.92

1.89

2.03

1.98

1.98

1.92

1.89

1.87

1.87

1.85

1.85

2.34

2.31

2.25

2.25

1.87

1.85

1.80

2.25

1.44

1.44

1.40

1.36

1.36

1.32

1.30

1.36

1.32

ampair.co.uk | 01707 378 670 | [email protected]

27

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V

1 unit

2 units

3 units

10

10

13

13

10

10

7

7

7

7

7

16

18

10

10

10

10

13

13

16

16

18

18

13

13

13

13

13

16

16

16

16

16

18

7

10

10

10

10

7

7

7

7

13

13

13

16

-

-

-

-

-

B

Indoor Unit

C D

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

10

13

13

13

10

10

10

10

13

16

13

13

-

-

-

-

-

-

-

-

-

-

-

-

7

7

7

7

7

7

7

7

7

7

7

-

-

10

10

10

10

10

7

7

7

7

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

16

18

13

16

16

18

10

13

18

18

7

10

13

10

13

16

18

13

18

16

18

18

18

13

16

18

16

18

16

18

16

16

18

18

18

10

13

16

18

13

16

18

16

7

10

13

16

10

13

A

7

16

18

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

E

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

E

-

3.79 3.41

3.60 3.60

-

-

2.00 2.00 2.00

2.70 2.00 2.00

3.65 1.97 1.97

4.08 1.81 1.81

4.28 1.71 1.71

2.70 2.70 2.00

3.39 2.48 1.83

3.77 2.26 1.67

3.97 2.14 1.59

3.03 3.03 1.64

3.44 2.83 1.53

3.64 2.70 1.46

3.19 3.19 1.42

3.39 3.05 1.36

3.29 3.29 1.32

2.53 2.53 2.53

3.13 2.28 2.28

3.50 2.10 2.10

3.70 2.00 2.00

2.82 2.82 2.06

A

2.00

Cooling Capacity (kW)

B C D

-

2.70

3.70

4.50

5.00

-

-

-

-

-

-

-

-

-

-

-

-

2.00 2.00

2.70 2.00

3.70 2.00

4.08 1.82

-

-

-

-

-

-

-

-

4.50 1.80

2.70 2.70

3.41 2.49

3.94 2.36

4.09 2.21

3.15 3.15

3.73 3.07

3.91 2.89

3.60 3.60

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3.22 2.65 1.93

3.42 2.53 1.85

3.04 3.04 1.82

3.20 2.88 1.73

3.11 3.11 1.68

2.60 2.60 2.60

2.99 2.46 2.46

3.19 2.36 2.36

2.80 2.80 2.30

2.67 2.67 2.67

2.99 2.69 2.21

2.88 2.88 2.13

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

E

-

4.49 4.11

4.30 4.30

-

-

2.70 2.70 2.70

3.53 2.38 2.38

4.13 2.23 2.23

4.39 2.16 2.16

4.58 2.06 2.06

3.18 3.18 2.14

3.72 2.97 2.01

3.92 2.85 1.93

4.11 2.74 1.85

3.43 3.43 1.85

3.67 3.33 1.80

3.85 3.21 1.73

3.57 3.57 1.75

3.76 3.45 1.69

3.63 3.63 1.63

2.87 2.87 2.87

3.35 2.68 2.68

3.54 2.58 2.58

3.73 2.49 2.49

3.11 3.11 2.49

A

2.70

Heating Capacity (kW)

B C D

-

4.00

5.00

5.50

6.00

-

-

-

-

-

-

-

-

-

-

-

-

2.70 2.70

4.00 2.70

4.81 2.59

5.10 2.50

-

-

-

-

-

-

-

-

5.45 2.45

3.60 3.60

4.22 3.38

4.57 3.33

4.74 3.16

3.95 3.95

4.35 3.95

4.53 3.77

4.30 4.30

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

3.34 3.03 2.43

3.56 2.97 2.37

3.26 3.26 2.37

3.45 3.16 2.30

3.34 3.34 2.23

2.93 2.93 2.93

3.16 2.87 2.87

3.34 2.78 2.78

3.06 3.06 2.78

2.97 2.97 2.97

3.24 2.97 2.70

3.14 3.14 2.62

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

@amp_aircon | amp-air-conditioning 28

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V 4 units

13

16

16

18

16

18

13

13

10

13

13

13

16

13

13

16

13

16

10

10

10

10

13

16

18

13

18

13

13

16

13

13

16

16

18

13

13

13

16

16

10

10

10

10

18

10

10

10

7

7

7

7

7

B

Indoor Unit

C D

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

10

10

10

7

7

7

7

7

7

7

7

7

7

7

7

7

13

13

13

13

10

13

13

13

13

13

13

13

13

10

10

10

13

10

10

10

10

13

13

13

13

13

13

13

13

13

10

10

13

13

10

10

10

10

10

10

10

10

10

10

10

10

10

10

7

7

7

7

7

7

7

7

7

7

7

7

7

10

10

10

10

10

10

10

10

10

18

16

18

18

18

18

13

16

18

13

16

18

16

13

16

16

18

18

10

13

16

18

18

18

18

13

18

13

16

16

16

18

16

18

18

13

16

18

16

18

18

10

13

16

10

13

16

18

10

13

16

18

A

7

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

E

-

A

Cooling Capacity (kW)

B C D

2.00 2.00 2.00 2.00

2.61 1.93 1.93 1.93

3.28 1.77 1.77 1.77

3.73 1.66 1.66 1.66

4.00 1.60 1.60 1.60

2.44 2.44 1.81 1.81

3.10 2.26 1.67 1.67

3.54 2.12 1.57 1.57

3.80 2.05 1.52 1.52

2.89 2.89 1.56 1.56

3.32 2.73 1.48 1.48

3.54 2.62 1.42 1.42

3.12 3.12 1.38 1.38

3.33 3.00 1.33 1.33

3.21 3.21 1.29 1.29

2.30 2.30 2.30 1.70

2.93 2.14 2.14 1.59

3.37 2.02 2.02 1.50

3.63 1.96 1.96 1.45

2.75 2.75 2.01 1.49

3.14 2.58 1.88 1.40

3.36 2.49 1.81 1.34

2.96 2.96 1.77 1.31

3.17 2.85 1.71 1.27

3.06 3.06 1.65 1.22

2.54 2.54 2.54 1.37

2.91 2.40 2.40 1.29

3.13 2.31 2.31 1.25

2.76 2.76 2.27 1.22

2.96 2.66 2.19 1.18

2.87 2.87 2.12 1.15

2.18 2.18 2.18 2.18

2.79 2.04 2.04 2.04

3.21 1.93 1.93 1.93

3.44 1.85 1.85 1.85

2.60 2.60 1.90 1.90

2.98 2.45 1.79 1.79

2.81 2.81 1.69 1.69

3.19 2.36 1.72 1.72

3.02 2.72 1.63 1.63

2.92 2.92 1.58 1.58

2.41 2.41 2.41 1.76

2.77 2.28 2.28 1.66

2.63 2.63 2.16 1.58

2.98 2.21 2.21 1.61

2.83 2.55 2.09 1.53

2.74 2.74 2.03 1.48

2.25 2.25 2.25 2.25

2.60 2.13 2.13 2.13

2.80 2.07 2.07 2.07

2.47 2.47 2.03 2.03

2.66 2.40 1.97 1.97

2.59 2.59 1.91 1.91

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

E

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

E

-

A

Heating Capacity (kW)

B C D

2.33 2.33 2.33 2.33

3.11 2.10 2.10 2.10

3.66 1.98 1.98 1.98

3.92 1.93 1.93 1.93

4.17 1.88 1.88 1.88

2.84 2.84 1.91 1.91

3.37 2.69 1.82 1.82

3.62 2.63 1.78 1.78

3.86 2.57 1.74 1.74

3.21 3.21 1.74 1.74

3.46 3.14 1.70 1.70

3.66 3.05 1.65 1.65

3.35 3.35 1.65 1.65

3.35 3.25 1.60 1.60

3.45 3.45 1.55 1.55

2.61 2.61 2.61 1.76

3.12 2.50 2.50 1.69

3.36 2.44 2.44 1.65

3.59 2.40 2.40 1.62

2.99 2.99 2.40 1.62

3.20 2.91 2.33 1.57

3.39 2.82 2.26 1.53

3.11 3.11 2.26 1.53

3.30 3.02 2.20 1.48

3.21 3.21 2.14 1.44

2.82 2.82 2.82 1.53

3.02 2.75 2.75 1.48

3.21 2.67 2.67 1.44

2.94 2.94 2.67 1.44

3.13 2.86 2.60 1.41

3.05 3.05 2.54 1.37

2.43 2.43 2.43 2.43

2.91 2.33 2.33 2.33

3.14 2.29 2.29 2.29

3.33 2.22 2.22 2.22

2.78 2.78 2.22 2.22

2.97 2.70 2.16 2.16

2.89 2.89 2.11 2.11

3.16 2.63 2.11 2.11

2.08 2.82 2.05 2.05

3.00 3.00 2.00 2.00

2.63 2.63 2.63 2.11

2.82 2.56 2.56 2.05

2.75 2.75 2.50 2.00

3.00 2.50 2.50 2.00

2.93 2.68 2.44 1.95

2.86 2.86 2.38 1.90

2.50 2.50 2.50 2.50

2.68 2.44 2.44 2.44

2.86 2.38 2.38 2.38

2.62 2.62 2.38 2.38

2.79 2.56 2.33 2.33

2.73 2.73 2.27 2.27

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V 5 units

13

16

18

13

18

16

18

10

18

13

16

18

16

16

16

13

16

16

16

18

16

13

13

16

18

16

10

13

16

18

13

16

18

13

16

18

16

18

10

13

13

16

10

13

16

18

10

13

A

7

16

18

10

10

10

13

16

16

16

10

10

13

13

13

16

13

16

13

13

16

13

13

16

13

13

13

13

16

10

10

10

10

13

13

13

13

13

13

16

16

10

10

10

10

10

10

13

10

7

7

7

7

7

B

Indoor Unit

C D

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

10

10

10

10

7

7

7

7

7

7

7

7

7

7

7

7

7

10

10

10

10

10

10

10

10

13

13

13

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

10

13

13

10

10

13

13

13

10

13

13

13

13

13

10

10

10

13

10

10

10

10

7

10

7

7

7

7

7

7

7

10

10

13

13

13

10

10

10

10

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

7

E

7

A

Cooling Capacity (kW)

B C D E A

Heating Capacity (kW)

B C D E

1.96 1.96 1.96 1.96 1.96 2.28 2.28 2.28 2.28 2.28

2.50 1.85 1.85 1.85 1.85 3.16 2.13 2.13 2.13 2.13

3.13 1.69 1.69 1.69 1.69 3.70 2.00 2.00 2.00 2.00

3.56 1.58 1.58 1.58 1.58 3.95 1.94 1.94 1.94 1.94

3.81 1.52 1.52 1.52 1.52 4.18 1.88 1.88 1.88 1.88

2.34 2.34 1.74 1.74 1.74 2.91 2.91 1.96 1.96 1.96

2.95 2.16 1.60 1.60 1.60 3.42 2.74 1.85 1.85 1.85

3.38 2.03 1.50 1.50 1.50 3.66 2.66 1.79 1.79 1.79

3.61 1.95 1.45 1.45 1.45 3.88 2.59 1.75 1.75 1.75

2.73 2.73 1.48 1.48 1.48 3.23 3.23 1.75 1.75 1.75

3.14 2.58 1.39 1.39 1.39 3.46 3.15 1.70 1.70 1.70

3.37 2.49 1.35 1.35 1.35 3.68 3.06 1.65 1.65 1.65

2.97 2.97 1.32 1.32 1.32 3.37 3.37 1.65 1.65 1.65

3.19 2.87 1.28 1.28 1.28 3.58 3.28 1.61 1.61 1.61

2.21 2.21 2.21 1.64 1.64 2.69 2.69 2.69 1.82 1.82

2.80 2.04 2.04 1.51 1.51 3.18 2.54 2.54 1.72 1.72

2.60 2.60 1.90 1.40 1.40 3.02 3.02 2.41 1.63 1.63

3.21 1.92 1.92 1.42 1.42 3.40 2.48 2.48 1.67 1.67

3.44 1.86 1.86 1.38 1.38 3.62 2.41 2.41 1.63 1.63

2.43 2.43 2.43 1.31 1.31 2.87 2.87 2.87 1.55 1.55

2.80 2.30 2.30 1.25 1.25 3.08 2.80 2.80 1.51 1.51

3.02 2.23 2.23 1.21 1.21 3.28 2.73 2.73 1.48 1.48

2.84 2.84 1.70 1.26 1.26 3.15 3.15 2.29 1.55 1.55

3.06 2.75 1.65 1.22 1.22 3.36 3.08 2.24 1.51 1.51

2.67 2.67 2.19 1.19 1.19 3.01 3.01 2.73 1.48 1.48

2.88 2.59 2.13 1.15 1.15 3.21 2.94 2.67 1.44 1.44

2.09 2.09 2.09 2.09 1.55 2.50 2.50 2.50 1.50 1.69

2.65 1.94 1.94 1.94 1.43 2.97 2.38 2.38 1.38 1.60

3.05 1.83 1.83 1.83 1.36 3.19 2.32 2.32 2.32 1.56

3.28 1.77 1.77 1.77 1.31 3.39 2.26 2.26 2.26 1.53

2.48 2.48 1.81 1.81 1.34 2.83 2.83 2.26 2.26 1.53

2.86 2.35 1.71 1.71 1.27 3.04 2.76 2.21 2.21 1.49

3.07 2.28 1.66 1.66 1.23 3.24 2.70 2.16 2.16 1.46

2.72 2.72 1.63 1.63 1.21 2.97 2.97 2.16 2.16 1.46

2.32 2.32 2.32 1.69 1.25 2.70 2.70 2.70 2.16 1.46

2.68 2.21 2.21 1.61 1.19 2.90 2.64 2.64 2.11 1.42

2.56 2.56 2.11 1.54 1.14 2.83 2.83 2.58 2.06 1.39

2.18 2.18 2.18 2.18 1.18 2.58 2.58 2.58 2.58 1.39

2.53 2.08 2.08 2.08 1.13 2.77 2.52 2.52 2.52 1.36

2.42 2.42 1.99 1.99 1.08 2.72 2.72 2.47 2.47 1.33

10 1.98 1.98 1.98 1.98 1.98 2.34 2.34 2.34 2.34 2.34

10 2.53 1.84 1.84 1.84 1.84 2.79 2.23 2.23 2.23 2.23

10 2.91 1.75 1.75 1.75 1.75 2.99 2.18 2.18 2.18 2.18

10 3.13 1.69 1.69 1.69 1.69 3.19 2.13 2.13 2.13 2.13

10 2.36 2.36 1.72 1.72 1.72 2.66 2.66 2.13 2.13 2.13

10 2.73 2.25 1.64 1.64 1.64 2.86 2.60 2.08 2.08 2.08

10 2.95 2.18 1.59 1.59 1.59 3.05 2.54 2.03 2.03 2.03

10 2.61 2.61 1.56 1.56 1.56 2.80 2.80 2.03 2.03 2.03

10 2.22 2.22 2.22 1.62 1.62 2.54 2.54 2.54 2.03 2.03

10 2.58 2.12 2.12 1.55 1.55 2.74 2.49 2.49 1.99 1.99

10 2.78 2.06 2.06 1.50 1.50 2.93 2.44 2.44 1.95 1.95

RAS Residential

Multi Split - Combination Tables

Power

Supply

Operating

Status

230V 5 units

A

16

13

16

18

16

13

16

13

13

16

13

13

16

13

B

Indoor Unit

C D

13

13

10

13

13

13

13

13

13

13

13

13

13

13

E A

Cooling Capacity (kW)

B C D E A

Heating Capacity (kW)

B C D E

10 2.49 2.49 2.04 1.49 1.49 2.85 2.75 2.50 2.00 2.00

10 2.09 2.09 2.09 2.09 1.53 2.44 2.44 2.44 2.44 1.95

10 2.46 2.02 2.02 2.02 1.48 2.69 2.45 2.45 2.45 1.96

10 2.66 1.97 1.97 1.97 1.44 2.88 2.40 2.40 2.40 1.92

10 2.36 2.36 1.94 1.94 1.41 2.64 2.64 2.40 2.40 1.92

10 2.00 2.00 2.00 2.00 2.00 2.40 2.40 2.40 2.40 2.40

10 2.33 1.92 1.92 1.92 1.92 2.59 2.35 2.35 2.35 2.35

Toshiba Rewards, the new loyalty scheme from

Toshiba, see page 207 for details

WHOLE NEW DIMENSION

@amp_aircon | amp-air-conditioning 32

TAKING OMFORT TO A

WHOLE NEW DIMENSION

RAV Split Systems

Toshiba installation at Mercedes Beaconsfield, courtesy of Tencer Ltd

RAV Split Systems

Introduction

Toshiba Digital and Super Digital Inverter systems deliver exceptional operating savings in extremely compact units. With state-ofthe-art technologies, flexible controls and flexible installation they bring comfort and convenience.

The technology of the Digital Inverter control module ensures optimised reproduction of the supply sine wave at the desired frequency, in order to reduce inefficient harmonics that inverters normally emit. With this innovative control method, the Toshiba Digital Inverter brings state-of-the-art inverter technology to the commercial sector, offering considerable advantages in terms of capacity, energy savings and optimised control.

The Super Digital Inverter provides industry leading part load efficiency in cooling and heating mode. In most applications, these systems can reduce the Seasonal

Energy Consumption. The variable capacity management of the compressor allows the

Digital and Super Digital Inverter to maintain room temperature control and to ensure minimum energy wastage.

Super Digital and Digital Inverter systems are capable of satisfying applications that require cooling at low operating conditions down to

–15°C, while powerful heating capacities are possible at –20°C outdoor temperature.

Thanks to the filter positioned in the refrigerant circuit, the SDI and DI systems, equipped with

R410A refrigerant, can use pipework designed for old R22 or R407C refrigerant. High-mesh filters and stable lubricant oil against chloride compounds, combined with high-tech Toshiba control, are key to make SDI and DI units suitable for reuse of existing piping. This solution offers significant benefits in terms of performance, acoustic comfort and efficiency.

@amp_aircon | amp-air-conditioning 34

RAV Split Systems

Range Overview

2.5

3.6

5.0

Nominal Cooling

6.7

10.0 12.0 14.0 20.0 25.0

Digital Inverter

1Ph

(37)

1Ph

(37)

1Ph

(38)

1Ph

(38)

KRT-E Wall

Mounted

Super Digital

Inverter

1Ph

(39)

1Ph

(39)

1Ph

(39)

Digital Inverter

MUT-E Compact

Cassette

Super Digital

Inverter

1Ph

(41)

1Ph

(41)

1Ph

(41)

1Ph

(42)

1Ph

(42)

UTP-E 4 Way

Cassette

Digital Inverter

Super Digital

Inverter

Digital Inverter

1Ph

(44)

1Ph

(44)

1Ph

(44)

1Ph

(45)

1Ph

(45)

1Ph

(46)

1Ph

(46)

1Ph

(47)

3Ph

(48)

1Ph

(47)

3Ph

(48)

3Ph

(48)

1Ph

(50)

1Ph

(50)

1Ph

(50)

SDT-E Low

Static Ducted

Super Digital

Inverter

1Ph

(51)

1Ph

(51)

BTP-E Standard

Ducted

Digital Inverter

Super Digital

Inverter

1Ph

(53)

1Ph

(53)

1Ph

(53)

1Ph

(54)

1Ph

(54)

1Ph

(54)

1Ph

(55)

1Ph

(55)

1Ph

(55)

1Ph

(56)

3Ph

(57)

1Ph

(56)

3Ph

(57)

3Ph

(57)

Digital Inverter

DT-E High Static

Ducted

Super Digital

Inverter

3Ph

(59)

3Ph

(59)

Digital Inverter

1Ph

(61)

1Ph

(61)

1Ph

(61)

1Ph

(62)

1Ph

(62)

1Ph

(62)

CTP-E Ceiling

Suspended

Super Digital

Inverter

1Ph

(63)

1Ph

(63)

1Ph

(63)

1Ph

(64)

3Ph

(65)

1Ph

(64)

3Ph

(65)

3Ph

(65)

Page numbers are shown in brackets | Floor standing converted systems are also available. See page 66 - 68 for details

| Twin, Triple and quad systems also available. See pages 70 - 79 for details.

ampair.co.uk | 01707 378 670 | [email protected]

35

RAV Split Systems

KRT-E Wall Mounted

KRT-E Wall Mounted Indoor Unit

Super Digital Inverter outdoor unit

With its slim-line design, the Super Digital Inverter high-wall unit is ideal for offices, restaurants and other applications where elegance is required.

»

»

High efficiency twin rotary inverter compressor

Replacement technology (R22 & R407c)

» High performance operation using digital inverter control system

»

Enhanced filtration system

» TCC link remote control options (optional)

» Auto louver mode allows optimum air distribution

»

Infrared and wired controls available

Existing

Pipe Sizes

Allowable Outdoors

Part No.

Compatible Accessories

Description

List

Price

£50 RBC-AMT32E Wired Remote Controller

RBC-AM-

S41E

RBC-AM-

S54E-ES

Wired remote controller with 7-day time clock

Premium wired remote controller with 7-day time clock

£66

£105

RBC-AS41E Simplified wired remote controller £70

AMP-TRF

Adapter for run/fault (12V DC output)

AMP-TRFVF Adapter for run/fault (volt free)

£16

£68

Liquid Gas Digital Inverter Super Digital Inverter

1/4"

1/4"

1/4"

3/8"

3/8"

3/8"

3/8"

3/8"

1/2"

5/8"

3/8"

1/2"

5/8"

3/4"

304, 404

304, 404, 564, 804

404, 564, 804

304

304, 404, 564, 804

404, 564, 804

804

404

404, 564, 804

404, 564, 804

404, 564, 804

404, 564, 804

804

Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information

Contact AMP for details.

£110

@amp_aircon | amp-air-conditioning 36

RAV Split Systems

Wall Mounted Digital Inverter

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Max Running Current

Power Consumption (Cool - Heat)

Suggested Fuse Size

Indoor Unit

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

275 - 790 - 217

550 - 780 - 290

10 - 33

83 - 128 - 158 n/a n/a

29 - 37 - 41

46 - 47

3/8" - 1/4"

20 - 10

15

0.8kg - 20g/m

Yes

VP16 (14id 16od)

230 - 1 - 50

3 core + E

3.86

0.61 - 0.85

10

£292

£588

£880

RAV-SM307KRTP-E

Included

RAV-SM304ATP-E

2.5 (0.9 - 3.0)

2.40 - 1.90

3.4 (0.8 - 4.5)

2.2

5.90 - 4.00

A+ / A+

4.10 - 4.00

TBC

RAV-SM407KRTP-E

Included

RAV-SM404ATP-E

3.6 (0.9 - 4.0)

3.45 - 2.70

4.0 (0.8 - 5.0)

2.6

5.40 - 4.12

A / A+

3.19 - 3.57

TBC

46°C to -15°C

15°C to -15°C

275 - 790 - 217

550 - 780 - 290

10 - 39

83 - 145 - 191 n/a n/a

30 - 40 - 45

49 - 50

1/2" - 1/4"

20 - 10

15

1.4kg - 20g/m

Yes

VP16 (14id 16od)

230 - 1 - 50

3 core + E

5.14

1.13 - 1.12

10

£317

£704

£1,021

Gravity drain | Rear, top, left or right piping.

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

37

RAV Split Systems

Wall Mounted Digital Inverter

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

AMBIENT RANGE

Cooling

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

320 - 1050 - 228

550 - 780 - 290

12 - 40

183 - 208 - 233 n/a n/a

36 - 39 - 42

46 - 48

1/2" - 1/4"

30 - 30

20

1.1kg - 20g/m

Yes

VP16 (14id 16od)

230 - 1 - 50

3 core + E

7.78 - 7.26

1.66 - 1.55

16 - 12.3

£391

£840

£1,231

RAV-SM566KRT-E

Included

RAV-SM564ATP-E

5.0 (1.5 - 5.6)

4.8 - 3.4

5.3 (1.5 - 6.3)

3.8

5.77 - 4.00

A+ / A+

3.01 - 3.42

B / B

RAV-SM806KRT-E

Included

RAV-SM804ATP-E

6.7 (1.5 - 7.0)

6.4 - 4.5

7.7 (1.5 - 9.0)

5.5

5.62 - 4.01

A+ / A+

2.75 - 2.95

D / D

46°C to -15°C

15°C to -15°C

320 - 1050 - 228

550 - 780 - 290

12 - 44

183 - 208 - 283 n/a n/a

36 - 41 - 47

48 - 52

5/8" - 3/8"

30 - 30

20

1.7kg - 40g/m

Yes

VP16 (14id 16od)

230 - 1 - 50

3 core + E

11.43 - 12.23

2.44 - 2.61

20 - 15.5

£421

£1,177

£1,598

Gravity drain | Rear, top, left or right piping.

@amp_aircon | amp-air-conditioning 38

RAV Split Systems

Wall Mounted Super Digital Inverter

Indoor Unit

Infrared Remote Controller

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

RAV-SM407KRTP-E

Included

RAV-SP404ATP-E

3.6 (TBC)

TBC

4.0 (TBC)

TBC

5.40 - 4.12

A / A+

TBC

TBC

275 - 790 - 217

550 - 780 - 290

10 - 40

83 - 145 - 191 n/a n/a

30 - 40 - 45

45 - 47

1/2" - 1/4"

30 - 30

15

1.0kg - 20g/m

Yes

VP16 (14id 16od)

230 - 1 - 50

3 core + E

5.14

1.13 - 1.12

10 - TBC

£317

£998

£1,315

36 - 39 - 42

47 - 48

1/2" - 1/4"

50 - 30

20

1.4kg - 20g/m

Yes

VP16 (14id 16od)

230 - 1 - 50

3 core + E

6.74 - 6.98

1.44 - 1.50

16 - 13.4

£391

£1,097

£1,488

RAV-SM566KRT-E

Included

RAV-SP564ATP-E

5.0 (1.2 - 5.6)

4.8 - 3.4

5.6 (0.9 - 7.3)

3.7

5.82 - 4.01

A+ / A+

3.47 - 3.73

A / A

43°C to -15°C

15°C to -20°C

320 - 1050 - 228

550 - 780 - 290

12 - 44

183 - 208 - 233 n/a n/a

RAV-SM806KRT-E

Included

RAV-SP804ATP-E

7.1 (1.9 - 8.0)

6.7 - 4.7

8.0 (1.3 - 10.6)

5.2

5.88 - 3.87

A+ / A

3.21 - 3.42

A / B

320 - 1050 - 228

890 - 900 - 320

12 - 66

183 - 208 - 283 n/a n/a

36 - 41 - 47

48 - 49

5/8" - 3/8"

50 - 30

30

2.1kg - 40g/m

Yes

VP16 (14id 16od)

230 - 1 - 50

3 core + E

10.71 - 11.02

2.21 - 2.34

25 - 20.4

£421

£1,628

£2,049

Gravity drain | Rear, top, left or right piping.

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

39

RAV Split Systems

MUT-E Compact Cassettes

MUT-E 4-way compact cassette

Super digital outdoor unit

The Super Digital Inverter series of cassettes are unobtrusive and flexible easily blending in with any room interior. They offer high performance utilising minimum energy to help lower your power consumption.

»

»

High efficiency twin rotary inverter compressor

Replacement technology (R22 & R407c)

» Lightweight and easy to install

» Built in drain pump up to 850mm

» Self cleaning function and anti-mould drain pan

»

Removable corner pockets for easy access

» Infrared and wired controls available

»

Operational to -15°C in cooling and -20°C heating

Part No.

Compatible Accessories

Description

List

Price

£50 RBC-AMT32E Wired Remote Controller

RBC-AM-

S41E*

RBC-AM-

S54E-ES

Wired remote controller with 7-day time clock

Premium wired remote controller with 7-day time clock

£66

£105

RBC-AS41E Simplified wired remote controller £70

Existing

Pipe Sizes

Allowable Outdoors

Liquid Gas Digital Inverter Super Digital Inverter

1/4"

1/4"

1/4"

3/8"

3/8"

3/8"

3/8"

1/2"

5/8"

3/8"

1/2"

5/8"

304, 404

304, 404, 564

404, 564

304

304, 404, 564

404, 564

404

404, 564

404, 564

404, 564

404, 564

Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information

Contact AMP for details.

TCB-AX32E2 Infrared remote controller kit

TCB-PCNT-

30TLE2**

AMP-TRF

Network adapter for connection to central controllers

Adapter for run/fault (12V DC output)

£214

£78

£16

AMP-TRFVF Adapter for run/fault (volt free) £68

£110

*System princes include these as standard | **Require TCB-PX30MUE adapter box £59.00.

@amp_aircon | amp-air-conditioning 40

RAV Split Systems

Compact Cassettes Digital Inverter

Indoor Unit

Grille

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating kW kW kW kW

°C

°C

RAV-SM304MUT-E

RBC-UM11PG(W)E

RBC-AMS41E

RAV-SM304ATP-E

2.5 (0.9 - 3.0)

2.40 - 1.95

3.4 (0.8 - 4.5)

2.18

5.53 - 4.27

A / A+

4.24 - 4.47

TBC

RAV-SM404MUT-E

RBC-UM11PG(W)E

RBC-AMS41E

RAV-SM404ATP-E

3.6 (0.9 - 4.0)

3.45 - 2.79

4.0 (0.8 - 5.0)

2.56

5.35 - 4.27

A / A+

4.00 - 4.21

TBC

46°C to -15°C

15°C to -15°C

268 (27) - 575 (700) -

575 (700)

RAV-SM564MUT-E

RBC-UM11PG(W)-E

RBC-AMS41E

RAV-SM564ATP-E

5.0 (1.5 - 5.6)

4.80 - 3.50

5.3 (1.5 - 6.3)

3.79

5.48 - 4.16

A / A+

3.03 - 3.49

B / B

Indoor Unit Dimensions (H-W-D) mm

268 (27) - 575 (700) -

575 (700)

268(27)- 575(700 )-

575(700)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size

Indoor Unit

Grille / Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

dB(A) dB(A) in m m kg mm kg l/s

Pa mm

V-Ph-Hz

A kW

A

550 - 780 - 290

16 (3) - 33

122 - 144 - 177 n/a n/a

31 - 36 - 40

46 - 47

3/8" - 1/4"

20 - 10

15

0.8kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

3.45

0.59 - 0.76

10

£538

£200

£66

£588

£1,392

550 - 780 - 290

16 (3) - 39

130 - 153 - 183 n/a n/a

31 - 36 - 40

49 - 50

1/2" - 1/4"

20 - 10

15

1.4kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

4.32

0.90 - 0.95

10

£532

£200

£66

£704

£1,502

550 - 780 - 290

17 (3) - 40

152 - 187 - 222 n/a n/a

34 - 39 - 43

46 - 48

1/2" - 1/4"

30 - 30

20

1.1kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

7.73 - 7.12

1.65 - 1.52

16 - 12.5

£526

£200

£66

£840

£1,632

Lift pump, 850mm from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake.

ampair.co.uk | 01707 378 670 | [email protected]

41

RAV Split Systems

Compact Cassettes Super Digital Inverter

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Grille

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Suggested Fuse Size - Max. Current

Indoor Unit

Grille / Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

°C

°C mm mm kg l/s

Pa dB(A) dB(A) in m m kg

A kW

A kW kW kW kW mm

V-Ph-Hz

RAV-SM404MUT-E

RBC-UM11PG(W)-E

RBC-AMS41E

RAV-SP404ATP-E

3.6

3.4 - 2.7

4.0

2.6

5.38 - 4.17

A / A+

3.60 - 4.12

A / A

43°C to -15°C

15°C to -15°C

268 (27) - 575 (700 ) - 575 (700)

550 - 780 - 290

17 (3) - 40

130 - 153 - 183 n/a n/a

31 - 36 - 40

45 - 47

1/2" - 1/4"

30 - 30

20

1.0kg - 20g/m yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

5.05 - 4.79

1.00 - 0.97

20 - 15.0

£532

£200

£66

£998

£1,796

RAV-SM564MUT-E

RBC-UM11PG(W)-E

RBC-AMS41E

RAV-SP564ATP-E

5.0

4.8 - 3.5

5.6

3.6

5.61 - 4.20

A+ / A+

3.21 - 3.64

A / A

43°C to -15°C

15°C to -20°C

268 (27) - 575 (700) - 575 (700)

550 - 780 - 290

17 (3) - 44

152 - 187 - 222 n/a n/a

34 - 39 - 43

47 - 48

1/2" - 1/4"

50 - 30

20

1.4kg - 20g/m yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

7.24 - 7.14

1.56 - 1.54

16 - 13.6

£526

£200

£66

£1,097

£1,889

Lift pump, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | Knock out for fresh air intake 64 x 64.

@amp_aircon | amp-air-conditioning 42

RAV Split Systems

UTP-E 4 Way Cassettes

UTP-E 4-way compact cassette

Digital inverter twin fan outdoor unit.

The Digital Inverter series of cassettes are unobtrusive and flexible which can easily blend in with any room interior. It is the ideal solution for applications where a ceiling void is present and easy access is required for maintenance and filter cleaning.

Part No.

Compatible Accessories

Description

RBC-AMT32E Wired Remote Controller

RBC-AM-

S41E*

RBC-AM-

S54E-ES

RBC-AX-

32U(W)-E

TCB-PCNT-

30TLE2

AMP-TRF

Infrared remote controller kit

Network adapter for connection to central controllers

Adapter for run/fault (12V DC output)

£78

£16

AMP-TRFVF Adapter for run/fault (volt free)

List

Price

£50

Wired remote controller with 7-day time clock

£66

Premium wired remote controller with 7-day time clock

£105

RBC-AS41E Simplified wired remote controller £70

£151

£68

£110

» Replacement technology (R22 & R407c)

» Lightweight and easy to install

»

Built in high lift drain pump up to 850mm

» Self cleaning function and anti-mould drain pan

» Removable corner pockets for easy access

» Infrared and wired controls available

»

Detachable louver and grille for easy cleaning

Existing

Pipe Sizes

Allowable Outdoors

Liquid

1/4"

1/4"

3/8"

3/8"

3/8"

Gas

1/2"

5/8"

1/2"

5/8"

3/4"

Digital Inverter

564, 804

564, 804

564, 804

564, 804, 1104,

1404, 1603

804, 1104, 1404,

1603

Super Digital Inverter

564, 804

564, 804

564, 804

564, 804, 1104,

1404

804, 1104, 1404

1/2"

1/2"

5/8"

3/4"

1104, 1404, 1603

1104, 1404, 1603

1104, 1404

1104, 1404

Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information

Contact AMP for details.

*System princes include these as standard.

ampair.co.uk | 01707 378 670 | [email protected]

43

RAV Split Systems

4 Way Cassettes Digital Inverter

Indoor Unit

Grille

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating kW kW kW kW

°C

°C

RAV-SM564UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SM564ATP-E

5.0 (1.5 - 5.6)

5.0 - 3.5

5.3 (1.5 - 6.3)

3.8

6.14 - 4.51

A++ / A+

3.21 - 3.90

A / A

RAV-SM804UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SM804ATP-E

6.7 (1.5 - 8.0)

6.4 - 4.2

7.7 (1.5 - 9.0)

5.5

5.81 - 4.05

A+ / A+

3.02 - 3.62

B / A

46°C to -15°C

15°C to -15°C

256 (30) - 840 (950) -

840 (950)

RAV-SM1104UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SM1104ATP-E

10.0 (3.0 - 11.2)

9.5 - 7.6

11.2 (3.0 - 13.0)

8.0

5.87 - 4.28

A+ / A+

3.31 - 3.82

A / A

Indoor Unit Dimensions (H-W-D) mm

256 (30) - 840 (950) -

840 (950)

319 (30) - 840 (950) -

840 (950)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size mm kg l/s

Pa dB(A) dB(A) in m m kg mm

V-Ph-Hz

A kW

A

550 - 780 - 290

20 (4.2) - 40

217 - 242 - 292 n/a n/a

28 - 29 - 32

46 - 48

1/2" - 1/4"

30 - 30

20

1.1kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

7.31 - 6.37

1.56 - 1.36

16 - 12.3

550 - 780 - 290

20 (4.2) - 44

225 - 267 - 342 n/a n/a

28 - 31 - 35

48 - 52

5/8" - 3/8"

30 - 30

20

1.7kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

10.40 - 9.98

2.22 - 2.13

20 - 14.3

Indoor Unit

Grille / Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

£610

£154

£66

£840

£1,670

£708

£154

£66

£1,177

£2,105

£793

£154

£66

£1,549

£2,562

Lift pump as standard, 850mm from the underside of the ceiling tile| Knock out for branch duct 105 x 105 | Knock out for fresh air intake 57 x 64.

890 - 900 - 320

24 (4.2) - 68

325 - 400 - 558 n/a n/a

33 - 38 - 43

53 - 54

5/8" - 3/8"

50 - 30

30

2.8kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

14.60 - 14.17

3.02 - 2.93

25 - 20.8

@amp_aircon | amp-air-conditioning 44

RAV Split Systems

4 Way Cassettes Digital Inverter

Indoor Unit

Grille

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D) kW kW kW kW

°C

°C mm

RAV-SM1404UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SM1404ATP-E

12.1 (3.0 - 13.2)

11.4 - 9.1

12.8 (3.0 - 16.0)

9.1

5.36 - 4.19

A / A+

2.80 - 3.76

D / A

RAV-SM1604UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SM1603AT-E

14.0 (3.0 - 16.0)

13.3 - 9.4

16.0 (3.0 - 18.0)

10.4

5.47 - 4.47

A / A

3.12 - 3.61

B / A

46°C to -15°C

15°C to -15°C

319 (30) - 840 (950) - 840 (950) 319 (30) - 840 (950) - 840 (950)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size mm kg l/s

Pa dB(A) dB(A) in m m kg mm

V-Ph-Hz

A kW

A

890 - 900 - 320

24 (4.2) - 68

342 - 400 - 583 n/a n/a

34 - 38 - 44

54 - 55

5/8" - 3/8"

50 - 30

30

2.8kg - 40g/m yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

20.74 - 16.44

3.57 - 3.40

25 - 22.8

1340 - 900 - 320

24 (4.2) - 99

350 - 417 - 592 n/a n/a

36 - 40 - 45

51 - 53

5/8" - 3/8"

50 - 30

30

3.1kg - 40g/m yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

21.48 - 21.20

4.49 - 4.43

32 - 29.7

Indoor Unit

Grille / Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

£815

£154

£66

£1,633

£2,668

£887

£154

£66

£2,059

£3,166

Lift pump as standard, 850mm from the underside of the ceiling tile| Knock out for branch duct 105 x 105 | Knock out for fresh air intake 57 x 64.

ampair.co.uk | 01707 378 670 | [email protected]

45

RAV Split Systems

4 Way Cassettes Super Digital Inverter Single Phase

Indoor Unit

Grille

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Grille / Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz dB(A) dB(A) in m m kg

°C

°C mm mm kg l/s

Pa

RAV-SM564UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SP564ATP-E

5.3 (1.2 - 5.6)

5.0 - 3.5

5.6 (0.9 - 8.1)

3.6

6.17 - 4.58

A++ / A+

3.61 - 4.63

A / A

RAV-SM804UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SP804ATP-E

7.1 (1.9 - 8.0)

6.7 - 4.5

8.0 (1.3 - 11.3)

5.2

6.39 - 4.19

A++ / A+

3.82 - 4.19

A / A

43°C to -15°C

15°C to -20°C

256 (30) - 840 (950) - 840 (950)

550 - 780 - 290

20 (4.2) - 44

256 (30) - 840 (950) - 840 (950)

890 - 900 - 320

20 (4.2) - 66

217 - 242 - 292 n/a n/a

28 - 29 - 32

47 - 48

1/2" - 1/4"

50 - 30

20

1.4kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

6.82 - 5.61

1.47 - 1.21

16 - 13.3

£610

£154

£66

£1,097

£1,927

225 - 267 - 342 n/a n/a

28 - 31 - 35

48 - 49

5/8" - 3/8"

50 - 30

30

2.1kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

8.72 - 8.95

1.86 - 1.91

25 - 20.3

£708

£154

£66

£1,628

£2,556

Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | knock out for fresh air intake 57 x 64.

@amp_aircon | amp-air-conditioning 46

RAV Split Systems

4 Way Cassettes Super Digital Inverter Single Phase

Indoor Unit

Grille

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Grille / Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz dB(A) dB(A) in m m kg

°C

°C mm mm kg l/s

Pa

RAV-SM1104UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SP1104AT-E

10.0 (2.6 - 12.0)

9.5 - 7.6

11.2 (2.4 - 13.0)

7.3

6.60 - 4.28

A++ / A+

4.52 - 4.79

A / A

RAV-SM1404UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SP1404AT-E

12.5 (2.6 - 14.0)

11.9 - 9.5

14.0 (2.4 - 16.5)

9.1

5.36 - 4.19

A / A+

3.96 - 4.36

A / A

319(30)- 840(950)- 840(950)

1340 - 900 - 320

24 (4.2) - 93

43°C to -15°C

15°C to -20°C

319(30)- 840(950)- 840(950)

1340 - 900 - 320

24 (4.2) - 93

325 - 400 - 558 n/a n/a

33 - 38 - 43

49 - 50

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

10.36 - 10.96

2.21 - 2.34

25 - 20.5

£793

£154

£66

£1,995

£3,008

342 - 400 - 583 n/a n/a

34 - 38 - 44

51 - 52

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

14.66 - 14.89

3.16 - 3.21

25 - 20.5

£815

£154

£66

£2,205

£3,240

Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | knock out for fresh air intake 57 x 64.

ampair.co.uk | 01707 378 670 | [email protected]

47

RAV Split Systems

4 Way Cassettes Super Digital Inverter Three Phase

Indoor Unit

Grille

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating kW kW kW kW

°C

°C

RAV-SM1104UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SP1104AT8-E

10.0 (2.6 - 12.0)

9.7 - 7.4

11.2 (2.4 - 15.6)

7.3

6.57 - 4.28

A++ / A++

4.22 - 4.63

A / A

RAV-SM1404UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SP1404AT8-E

12.5 (2.6 - 14.0)

12.1 - 8.4

14.0 (2.4 - 18.0)

9.1

5.87 - 4.86

A+ / A++

3.61 - 4.09

A / A

46°C to -15°C

15°C to -20°C

319 (30) - 840 (950) -

840 (950)

RAV-SM1604UTP-E

RBC-U31PGP(W)-E

RBC-AMS41E

RAV-SP1604AT8-E

14.0 (2.6 - 16.0)

13.5 - 9.0

16.0 (2.4 - 19.0)

10.4

5.49 - 4.73

A / A++

3.12 - 3.72

B / A

Indoor Unit Dimensions (H-W-D) mm

319 (30) - 840 (950) -

840 (950)

319 (30) - 840 (950) -

840 (950)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Grille / Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

mm kg dB(A) dB(A) m kg in m l/s

Pa mm

V-Ph-Hz

A kW

A

1340 - 900 - 320

24 (4.2) - 95

325 - 400 - 558 n/a n/a

33 - 38 - 43

49 - 50

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

400 - 3 - 50

3 core + E

4.54 - 4.52 per phase

2.37 - 2.42

20 - 14.7 per phase

£793

£154

£66

£2,184

£3,197

1340 - 900 - 320

24 (4.2) - 95

342 - 400 - 583 n/a n/a

34 - 38 - 44

51 - 52

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

400 - 3 - 50

3 core + E

6.03 - 5.97 per phase

3.46 - 3.42

20 - 14.7 per phase

£815

£154

£66

£2,279

£3,314

1340 - 900 - 320

24 (4.2) - 95

350 - 417 - 592 n/a n/a

36 - 40 -45

51 - 53

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

400 - 3 - 50

3 core + E

7.55 - 7.26 per phase

4.49 - 4.30

20 - 14.7 per phase

£887

£154

£66

£2,426

£3,533

Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct 105 x 105 | Knock out for fresh air intake 57 x 64.

@amp_aircon | amp-air-conditioning 48

RAV Split Systems

SDT-E Slim Ducted

SDT-E Slim Ducted Indoor Unit

Digital Inverter Outdoor Unit

The slim ducted unit is very compact with low height dimensions for flexible ceiling instillations.

» High efficiency twin rotary inverter compressor

»

Replacement technology (R22 & R407c)

» Slim 210mm deep ducted unit design

» Rear or underside return air

» Static pressure up to 50Pa

»

Extremely quiet operation

Part No.

Compatible Accessories

Description

List

Price

£50 RBC-AMT32E Wired Remote Controller

RBC-AM-

S41E*

RBC-AM-

S54E-ES

Wired remote controller with 7-day time clock

Premium wired remote controller with 7-day time clock

£66

£105

RBC-AS41E Simplified wired remote controller £70

RCB-AX32E2 Infrared remote controller kit £214

TCB-TC41LE Remote return air sensor

TCB-PCNT-

30TLE2

AMP-TRF

Network adapter for connection to central controllers

Adapter for run/fault (12V DC output)

£64

£78

£16

AMP-TRFVF Adapter for run/fault (volt free) £68

£110

*System princes include these as standard .

» Twin split also available

»

Infrared and wired control options available

» Operational to -15°C in cooling and heating

Existing

Pipe Sizes

Allowable Outdoors

Liquid Gas Digital Inverter Super Digital Inverter

1/4"

1/4"

1/4"

3/8"

3/8"

3/8"

3/8"

1/2"

5/8"

3/8"

1/2"

5/8"

304, 404

304, 404, 564

404, 564

304

304, 404, 564

404, 564

404

404, 564

404, 564

404, 564

404, 564

Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information

Contact AMP for details.

ampair.co.uk | 01707 378 670 | [email protected]

49

RAV Split Systems

Slim Ducted Digital Inverter

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

AMBIENT RANGE

Cooling

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Suggested Fuse Size - Max. Current

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

A kW

A kW kW kW kW mm

V-Ph-Hz

26 - 28 - 30*

46 - 47

3/8" - 1/4"

20 - 10

15

0.8kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

3.91

0.56 - 0.86

10 - TBC

£467

£66

£588

£1,121

RAV-SM304SDT-E

RBC-AMS41E

RAV-SM304ATP-E

2.5 (0.9 - 3.0)

2.40 - 1.97

3.4 (0.8 - 4.5)

2.18

RAV-SM404SDT-E

RBC-AMS41E

RAV-SM404ATP-E

3.6 (0.9 - 4.0)

3.45 - 2.84

4.0 (0.8 - 5.0)

2.56

6.10 - 4.48

A++ / A+

4.46 - 3.95

TBC

5.55 - 3.88

A / A

3.87 - 4.12

TBC

210 - 845 - 645

550 - 780 - 290

22 - 33

46°C to -15°C

24°C to -15°C

210 - 845 - 645

550 - 780 - 290

22 - 39

133 - 155 - 183

10 - 50

Rectangular Outlet

145 - 167 - 192

10 - 50

Rectangular Outlet

26 - 28 - 30*

49 - 50

1/2" - 1/4"

20 - 10

15

1.4kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

4.41

0.93 - 0.97

10 - TBC

£507

£66

£704

£1,277

28 - 31 - 33*

46 - 48

1/2" - 1/4"

30 - 30

20

1.1kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

8.95 - 7.03

1.91 - 1.50

16 - 13.6

£518

£66

£840

£1,424

RAV-SM564SDT-E

RBC-AMS41E

RAV-SM564ATP-E

5.0 (1.5 - 5.6)

4.8 - 3.3

5.3 (1.5 - 6.3)

3.79

5.06 - 4.06

B / A+

2.62 - 3.53

D / B

46°C to -15°C

15°C to -15°C

210 - 845 - 645

550 - 780 - 290

22 - 40

162 - 188 - 217

4 - 50

Rectangular Outlet

Rear or bottom return | * Sound pressure levels are for rear return, bottom return have higher sound pressure levels.

@amp_aircon | amp-air-conditioning 50

RAV Split Systems

Slim Ducted Super Digital Inverter

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (Upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Suggested Fuse Size - Max. Current

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

A kW

A kW kW kW kW mm

V-Ph-Hz

26 - 28 - 30*

45 - 47

1/2" - 1/4"

30 - 30

20

1.0kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

5.05 - 4.79

1.00 - 0.97

20 - 15.0

£507

£66

£998

£1,571

RAV-SM404SDT-E

RBC-AMS41E

RAV-SP404ATP-E

3.6

3.4 - 2.6

4.0

2.6

5.11 - 3.90

A / A

3.50 - 4.00

A / A

43°C to -15°C

15°C to -15°C

210 - 845 - 645

550 - 780 - 290

22 - 40

145 - 167 - 192

50

Rectangular Outlet

28 - 31 - 33*

47 - 48

1/2" - 1/4"

50 - 30

20

1.4kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

7.24 - 7.14

1.56 - 1.54

16 - 13.6

£518

£66

£1,097

£1,681

RAV-SM564SDT-E

RBC-AMS41E

RAV-SP564ATP-E

5.0

4.8 - 3.5

5.6

3.7

5.10 - 3.83

A / A

3.21 - 3.89

A / A

43°C to -15°C

15°C to -20°C

210 - 845 - 645

550 - 780 - 290

22 - 44

162 - 188 - 217

50

Rectangular Outlet

Rear or bottom return | * Sound pressure levels are for rear return, bottom return have higher sound pressure levels.

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

51

RAV Split Systems

BTP-E Standard Ducted

BTP-E Standard Ducted Unit DI twin fan outdoor unit

The Digital Inverter series of ducted units can be discreetly positioned in the ceiling. They are ideal for hotels, banks and similar applications where very low noise levels are needed.

Part No.

RBC-AMT32E Wired Remote Controller

RBC-

AMS41E*

RBC-

AMS54E-ES

Compatible Accessories

Description

List

Price

£50

Wired remote controller with 7-day time clock

£66

Premium wired remote controller with 7-day time clock

£105

» Unobtrusive installation above suspended ceilings

» High performance operation

»

Infrared and wired control options available

» High static pressure up to 120Pa

» High-lift drain pump kit to 550mm

» Uniform temperatures throughout the room

»

Extremely quiet operation

» Ideal for R22 & R407c replacement

RBC-AS41E Simplified wired remote controller £70

Existing

Pipe Sizes

Allowable Outdoors

TCB-AX32E2 Infrared remote controller kit £214

TCB-TC41LE Remote return air sensor £64

TCB-

PCNT30TLE2

Network adapter for connection to central controllers

£78

AMP-TRF

Adapter for run/fault (12V DC output)

£16

AMP-TRFVF Adapter for run/fault (volt free) £68

£110

*System princes include these as standard.

Liquid Gas Digital Inverter Super Digital Inverter

1/4"

1/4"

1/4"

3/8"

3/8"

3/8"

1/2"

1/2"

3/8"

1/2"

5/8"

1/2"

5/8"

3/4" 804, 1104, 1404, 1603 804, 1104, 1404

5/8"

3/4"

404

404, 564, 804

404, 564, 804

404, 564, 804

404, 564, 804, 1104,

1404, 1603

1104, 1404, 1603

1104, 1404, 1603

404

404, 564, 804

404, 564, 804

404, 564, 804

404, 564, 804, 1104,

1404

1104, 1404

1104, 1404

Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information

Contact AMP for details.

@amp_aircon | amp-air-conditioning 52

RAV Split Systems

Standard Ducted Digital Inverter

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Suggested Fuse Size - Max. Current

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

dB(A) dB(A) in m m kg

°C

°C mm mm kg l/s

Pa

A kW

A kW kW kW kW mm

V-Ph-Hz

RAV-SM406BTP-E

AMP-RAVBTE-2DUCT

RBC-AMS41E

RAV-SM404ATP-E

3.6 (TBC)

TBC

4.0 (TBC)

TBC

5.06 - 3.95

B / A

TBC

TBC

275 - 700 - 750

550 - 780 - 290

23 - 39

TBC

TBC

2 x 200mm

25 - 29 - 33

45 - 47

1/2" - 1/4"

20 - 10

15

1.4kg - 20g/m

Yes

TBC

230 - 1 - 50

3 core + E

TBC

TBC

10 - TBC

£528

£40

£66

£704

£1,338

RAV-SM566BTP-E

AMP-RAVBTE-2DUCT

RBC-AMS41E

RAV-SM564ATP-E

5.0 (1.5 - 5.6)

4.8 - 3.6

5.3 (1.5 - 6.3)

3.8

4.80 - 3.98

B / A

2.73 - 3.27

D / C

46°C to -15°C

15°C to -15°C

275 - 700 - 750

550 - 780 - 290

23 - 40

133 - 175 - 222

30 - 120

2 x 200mm

25 - 29 - 33

46 - 48

1/2" - 1/4"

30 - 30

20

1.1kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

8.58 - 7.59

1.83 - 1.62

16 - 12.9

£588

£40

£66

£840

£1,534

RAV-SM806BTP-E

AMP-RAVBTE-3DUCT

RBC-AMS41E

RAV-SM804ATP-E

6.7 (1.5 - 7.4)

6.2 - 4.8

7.7 (1.5 - 9.0)

5.5

5.04 - 3.83

B / A+

2.82 - 3.32

C / C

275 - 1000 - 750

550 - 780 - 290

30 - 44

200 - 258 - 333

30 - 120

3 x 200mm

26 - 30 - 34

48 - 52

5/8" - 3/8"

30 - 30

20

1.7kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

11.15 - 10.87

2.38 - 2.32

20 - 15.4

£843

£54

£66

£1,177

£2,140

Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.

ampair.co.uk | 01707 378 670 | [email protected]

53

RAV Split Systems

Standard Ducted Digital Inverter

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Suggested Fuse Size - Max. Current

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

dB(A) dB(A) in m m kg

°C

°C mm mm kg l/s

Pa

A kW

A kW kW kW kW mm

V-Ph-Hz

RAV-SM1106BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SM1104ATP-E

10.0 (3.0 - 11.2)

9.5 - 7.7

11.2 (3.0 - 12.5)

8.0

5.03 - 4.14

B / A+

3.18 - 3.75

B / A

275 - 1400 - 750

890 - 900 - 320

40 - 68

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

53 - 54

5/8" - 3/8"

50 - 30

30

2.8kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

15.18 - 14.46

3.14 - 2.99

25 - 22.0

£964

£67

£66

£1,549

£2,646

RAV-SM1406BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SM1404ATP-E

12.1 (3.0 - 13.2)

11.5 - 8.9

12.8 (3.0 - 16.0)

9.2

5.53 - 4.42

A / A+

2.74 - 3.61

D / A

46°C to -15°C

15°C to -15°C

275 - 1400 - 750

890 - 900 - 320

40 - 68

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

54 - 55

5/8" - 3/8"

50 - 30

30

2.8kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

21.37 - 17.17

4.42 - 3.55

25 - 22.8

£1,076

£67

£66

£1,633

£2,841

RAV-SM1606BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SM1603AT-E

14.0 (3.0 - 16.0)

13.3 - 9.3

16.0 (3.0 - 18.0)

10.5

4.78 - 3.89

B / A

2.73 - 3.41

D / B

275 - 1400 - 750

1340 - 900 - 320

40 - 99

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

51 - 53

5/8" - 3/8"

50 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

24.54 - 22.44

5.13 - 4.69

TBC - TBC

£1,174

£67

£66

£2,059

£3,366

Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.

@amp_aircon | amp-air-conditioning 54

RAV Split Systems

Standard Ducted Super Digital Inverter Single Phase

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Suggested Fuse Size - Max. Current

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

dB(A) dB(A) in m m kg

°C

°C mm mm kg l/s

Pa

A kW

A kW kW kW kW mm

V-Ph-Hz

133 - 175 - 222

30 - 120

2 x 200mm

25 - 29 - 33

45 - 47

1/2" - 1/4"

30 - 30

20

1.0kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

5.40 - 5.13

1.07 - 1.04

16 - 11.2

£528

£40

£66

£998

£1,632

RAV-SM406BTP-E

AMP-RAVBTE-2DUCT

RBC-AMS41E

RAV-SP404ATP-E

3.6 (1.5 - 4.0)

3.4 - 3.0

4.0 (1.5 - 5.0)

2.6

5.10 - 4.02

A / A+

3.38 - 3.84

A / A

43°C to -15°C

15°C to -15°C

275 - 700 - 750

550 - 780 - 290

23 - 40

RAV-SM566BTP-E

AMP-RAVBTE-2DUCT

RBC-AMS41E

RAV-SP564ATP-E

5.0 (1.2 - 5.6)

4.8 - 3.6

5.6 (0.9 - 7.4)

3.7

4.88 - 4.01

B / A+

3.21 - 3.61

A / A

133 - 175 - 222

30 - 120

2 x 200mm

25 - 29 - 33

47 - 48

1/2" - 1/4"

50 - 30

20

1.4kg - 20g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

7.23 - 7.18

1.56 - 1.55

16 - 13.7

£588

£40

£66

£1,097

£1,791

RAV-SM806BTP-E

AMP-RAVBTE-3DUCT

RBC-AMS41E

RAV-SP804ATP-E

7.1 (1.9 - 8.0)

6.7 - 5.1

8.0 (1.3 - 10.6)

5.2

5.88 - 4.00

A+ / A+

3.45 - 3.62

A / A

275 - 700 - 750

550 - 780 - 290

23 - 44

43°C to -15°C

15°C to -20°C

275 - 1000 - 750

890 - 900 - 320

30 - 66

200 - 258 - 333

30 - 120

3 x 200mm

26 - 30 - 34

48 - 49

5/8" - 3/8"

50 - 30

30

2.1kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

9.65 - 10.30

2.06 - 2.21

25 - 20.7

£843

£54

£66

£1,628

£2,591

Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.

ampair.co.uk | 01707 378 670 | [email protected]

55

RAV Split Systems

Standard Ducted Super Digital Inverter Single Phase

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Suggested Fuse Size - Max. Current

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

kW kW kW kW

RAV-SM1106BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SP1104AT-E

10.0 (2.6 - 12.0)

9.7 - 7.2

11.2 (2.4 - 13.0)

7.3

5.65 - 3.87

A+ / A

3.79 - 4.04

A / A

RAV-SM1406BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SP1404AT-E

12.5 (2.6 - 14.0)

12.1 - 9.0

14.0 (2.4 - 16.5)

9.1

5.22 - 4.03

A / A+

3.26 - 3.81

A / A dB(A) dB(A) in m m kg

°C

°C mm mm kg l/s

Pa

43°C to -15°C

15°C to -20°C mm

V-Ph-Hz

A kW

A

275 - 1400 - 750

1340 - 900 - 320

40 - 93

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

49 - 50

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

12.30 - 12.90

2.64 - 2.77

25 - 22.3

£964

£67

£66

£1,995

£3,092

275 - 1400 - 750

1340 - 900 - 320

40 - 93

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

51 - 52

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

230 - 1 - 50

3 core + E

TBC

TBC

25 - 22.6

£1,076

£67

£66

£2,205

£3,414

Lift pump as standard, 550mm from the underside of the unit | Bottom return as standard, rear return possible.

@amp_aircon | amp-air-conditioning 56

RAV Split Systems

Standard Ducted Super Digital Inverter Three Phase

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Suggested Fuse Size- Max. Current

Indoor Unit

Spigot Kit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

°C

°C mm mm kg l/s

Pa dB(A) dB(A) in m m kg

A kW

A kW kW kW kW mm

V-Ph-Hz

RAV-SM1106BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SP1104AT8-E

10.0 (2.6 - 12.0)

9.7 - 7.2

11.2 (2.4 - 15.6)

7.3

5.65 - 3.87

A+ / A

3.79 - 4.04

A / A

275 - 1400 - 750

1340 - 900 - 320

40 - 95

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

49 - 50

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

400 - 3 - 50

3 core + E

3.72 per phase

2.64 - 2.77

20 - 16.2 per phase

£964

£67

£66

£2,184

£3,281

RAV-SM1406BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SP1404AT8-E

12.5 (2.6 - 14.0)

12.1 - 9.0

14.0 (2.4 - 18.0)

9.1

5.09 - 4.48

B / A+

3.24 - 3.81

A / A

46°C to -15°C

15°C to -20°C

275 - 1400 - 750

1340 - 900 - 320

40 - 95

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

51 - 52

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

400 - 3 - 50

3 core + E

5.42 per phase

3.86 - 3.67

20 - 16.5 per phase

£1,076

£67

£66

£2,279

£3,488

RAV-SM1606BTP-E

AMP-RAVBTE-4DUCT

RBC-AMS41E

RAV-SP1604AT8-E

14.0 (2.6 - 16.0)

13.5 - 10.1

16.0 (2.4 - 19.0)

10.5

4.97 - 4.35

B / A+

3.01 - 3.48

B / B

275 - 1400 - 750

1340 - 900 - 320

40 - 95

350 - 458 - 583

50 - 120

4 x 200mm

33 - 36 - 40

51 - 53

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP25 (25id 32od)

400 - 3 - 50

3 core + E

6.66 per phase

4.65 - 4.60

20 - 16.9 per phase

£1,174

£67

£66

£2,426

£3,733

Lift pump as standard, 850mm from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake.

ampair.co.uk | 01707 378 670 | [email protected]

57

RAV Split Systems

DT-E High Static Ducted

DT-E high static ducted RAV-SM2804AT8-E outdoor unit

This range of units has been designed to provide a high capacity output from a very small footprint.

Part No.

Compatible Accessories

Description

List

Price

£50 RBC-AMT32E Wired Remote Controller

RBC-

AMS41E*

RBC-

AMS54E-ES

Wired remote controller with 7-day time clock

Premium wired remote controller with 7-day time clock

£66

£105

RBC-AS41E Simplified wired remote controller £70

TCB-AX32E2 Infrared remote controller kit £214

TCB-TC41LE Remote return air sensor £64

TCB-

PCNT30TLE2

Network adapter for connection to central controllers

£78

AMP-TRF

Adapter for run/fault (12V DC output)

£16

AMP-TRFVF Adapter for run/fault (volt free) £68

£110

*System princes include these as standard.

»

Maximum external static pressure 196Pa

» 3 stage selectable static pressure setting

» Digital inverter large outdoor unit

» Ideal for larger shops and retail premises

»

Outdoor unit 400V, 3 phase supply

» High efficiency twin rotary inverter compressor

» Space saving small footprint

Existing

Pipe Sizes

Allowable Outdoors

Liquid Gas Digital Inverter Super Digital Inverter

1/2" 7/8"

1/2" 1 1/8"

5/8" 7/8"

5/8" 1 1/8"

2244, 2804

2244, 2804

2244, 2804

2244, 2804

Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information

Contact AMP for details.

@amp_aircon | amp-air-conditioning 58

RAV Split Systems

High Static Ducted Digital Inverter

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Suggested Fuse Size

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

kg l/s

Pa

°C

°C mm mm dB(A) dB(A) in m m kg

A kW

A kW kW kW kW mm

V-Ph-Hz

RAV-SM2242DT-E

RBC-AMS41E

RAV-SM2244AT8-E

20.0 (9.8 - 22.4)

19.3 - 15.0

22.4 (9.8 - 25.0)

14.60

4.15 - 4.11

C / A+

2.78 - 3.45

D / B

RAV-SM2802DT-E

RBC-AMS41E

RAV-SM2804AT8-E

23.0 (9.8 - 27.0)

22.2 - 16.7

27.0 (9.8 - 31.5)

17.60

4.51 - 3.98

C / A

2.63 - 3.31

D / C

46°C to -15°C

15°C to -20°C

470 - 1380 - 1250

1540 - 900 - 320

160 - 134

1000

68.6 - 137.0 - 196.0

Rectangular Outlet

54

56 - 57

1 1/8" - 1/2"

70 - 30

30

5.9kg - 80g/m

Yes

32 (VP25 (25id 32od))

470 - 1380 - 1250

1540 - 900 - 320

160 - 134

1167

68.6 - 137.0 - 196.0

Rectangular Outlet

55

57 - 58

1 1/8" - 1/2"

70 - 30

30

5.9kg - 80g/m

Yes

32 (VP25 (25id 32od))

400 - 3 - 50 & indoor 230- 1 -50

3 core + E

Outdoor 18.0A - indoor 15.0A

7.20 - 6.49

400 - 3 - 50 & indoor 230- 1 -50

3 core + E

Outdoor 20.0A - indoor 15.0A

8.75 - 8.15

Outdoor 25A per phase - indoor 20A Outdoor 32A per phase - indoor 20A

£2,622 £2,826

£66

£3,000

£5,688

£66

£3,095

£5,987

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

59

RAV Split Systems

CTP-E Ceiling Suspended

CTP-E ceiling suspended unit

Existing

Pipe Sizes

Digital inverter single fan outdoor unit

The Digital Inverter series of ceiling suspended units can be discreetly positioned under the ceiling. They are ideal for offices, classrooms and restaurants.

» Easy installation and maintenance

»

High performance operation, using digital inverter control

» Infrared and wired controls available

»

Low noise levels

» Ideal for R22 and R407c replacement

» Automatic louver control for colling and heating models plus auto-swing

Allowable Outdoors

Part No.

Compatible Accessories

Description

List

Price

£50 RBC-AMT32E Wired Remote Controller

RBC-AM-

S41E*

RBC-AM-

S54E-ES

Wired remote controller with 7-day time clock

Premium wired remote controller with 7-day time clock

£66

£105

RBC-AS41E Simplified wired remote controller £70

RBC-AX33CE Infrared remote controller kit £166

TCB-

PCNT30TLE2

AMP-TRF

Network adapter for connection to central controllers

Adapter for run/fault (12V DC output)

£78

£16

AMP-TRFVF Adapter for run/fault (volt free) £68

Liquid Gas Digital Inverter Super Digital Inverter

1/4"

1/4"

1/4"

3/8"

3/8"

3/8"

1/2"

1/2"

3/8"

1/2"

5/8"

5/8"

3/4"

404

404, 564, 804

404, 564, 804

1104, 1404, 1603

1104, 1404, 1603

404

404, 564, 804

404, 564, 804

1/2"

5/8"

404, 564, 804

404, 564, 804, 1104,

1404, 1603

404, 564, 804

404, 564, 804, 1104,

1404

3/4" 804, 1104, 1404, 1603 804, 1104, 1404

1104, 1404

1104, 1404

Subject to the pipe sizes used and selected outdoor unit additional pipe work and capacity, limitations may apply, see page 222 for further information

Contact AMP for details.

£110

*System princes include these as standard

@amp_aircon | amp-air-conditioning 60

RAV Split Systems

Ceiling Suspended Digital Inverter

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

28 - 35 - 37

49 - 50

1/2" - 1/4"

20 - 10

15

1.4kg - 20g/m

Yes

VP20

230 - 1 - 50

3 core + E

5.48

1.20 - 0.78

10 - TBC

£604

£66

£704

£1,374

RAV-SM407CTP-E

RBC-AMS41E

RAV-SM404ATP-E

3.6 (0.9 - 4.0)

3.45 - 2.89

4.0 (0.8 - 5.0)

2.56

5.96 - 4.98

A+ / A++

4.34 - 5.13

TBC

46°C to -15°C

24°C to -15°C

235 - 950 - 690

550 - 780 - 290

23 - 39

150 - 200 - 250 n/a n/a

28 - 35 - 37

46 - 48

1/2" - 1/4"

30 - 30

20

1.1kg - 20g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

7.54 - 6.37

1.61 - 1.36

16 - 12.8

£658

£66

£840

£1,564

RAV-SM567CTP-E

RBC-AMS41E

RAV-SM564ATP-E

5.0 (1.5 - 5.6)

4.8 - 3.6

5.3 (1.5 - 6.3)

3.8

RAV-SM807CTP-E

RBC-AMS41E

RAV-SM804ATP-E

6.9 (1.5 - 7.4)

6.6 - 5.0

7.7 (1.5 - 9.0)

5.5

5.41 - 4.21

A / A+

3.11 - 3.90

B / A

5.62 - 4.01

A+ / A+

2.90 - 3.62

C / A

235 - 950 - 690

550 - 780 - 290

23 - 40

46°C to -15°C

15°C to -15°C

235 - 1270 - 690

550 - 780 - 290

29 - 44

150 - 200 - 250 n/a n/a

208 - 278 - 392 n/a n/a

29 - 36 - 41

48 - 52

5/8" - 3/8"

30 - 30

20

1.7kg - 40g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

11.15 - 9.98

2.38 - 2.13

20 - 15.1

£779

£66

£1,177

£2,022

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

61

RAV Split Systems

Ceiling Suspended Digital Inverter

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

AMBIENT RANGE

Cooling

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

RAV-SM1107CTP-E

RBC-AMS41E

RAV-SM1104ATP-E

10.0 (3.0 - 11.2)

9.5 - 7.2

11.2 (3.0 - 12.5)

8.0

5.79 - 4.27

A+ / A+

3.22 - 3.81

B / A

235 - 1586 - 690

890 - 900 - 320

35 - 68

283 - 375 - 517 n/a n/a

32 - 38 - 44

53 - 54

5/8" - 3/8"

50 - 30

30

2.8kg - 40g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

15.04 - 14.22

3.11 - 2.94

20 - 21.6

£849

£66

£1,549

£2,464

35 - 41 - 46

54 - 55

5/8" - 3/8"

50 - 30

30

2.8kg - 40g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

21.37 - 16.59

4.42 - 3.43

25 - 22.8

£1,071

£66

£1,633

£2,770

RAV-SM1407CTP-E

RBC-AMS41E

RAV-SM1404ATP-E

12.1 (3.0 - 13.2)

11.5 - 8.4

12.8 (3.0 - 16.0)

9.1

5.53 - 4.55

A / A+

2.74 - 3.73

D / A

46°C to -15°C

15°C to -15°C

235 - 1586 - 690

890 - 900 - 320

35 - 68

333 - 425 - 567 n/a n/a

RAV-SM1607CTP-E

RBC-AMS41E

RAV-SM1603AT-E

14.0 (3.0 - 16.0)

13.3 - 9.3

16.0 (3.0 - 18.0)

10.4

4.94 - 4.36

B / A+

3.01 - 3.47

C / B

235 - 1586 - 690

1340 - 900 - 320

35 - 99

350 - 458 - 567 n/a n/a

36 - 42 - 46

51 - 53

5/8" - 3/8"

50 - 30

30

3.1kg - 40g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

22.25 - 22.06

4.65 - 4.61

tbc - tbc

£1,090

£66

£2,059

£3,215

@amp_aircon | amp-air-conditioning 62

RAV Split Systems

Ceiling Suspended Super Digital Inverter Single Phase

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

28 - 35 - 37

45 - 47

1/2" - 1/4"

30 - 30

15

1.0kg - 20g/m

Yes

VP20

230 - 1 - 50

3 core + E

TBC

TBC

20

£604

£66

£998

£1,668

RAV-SM407CTP-E

RBC-AMS41E

RAV-SP404ATP-E

3.6 (TBC)

TBC

4.0 (TBC)

TBC

5.96 - 4.98

A+ / A++

TBC

TBC

46°C to -15°C

15°C to -15°C

235 - 950 - 690

550 - 780 - 290

23 - 40

150 - 200 - 250 n/a n/a

28 - 35 - 37

47 - 48

1/2" - 1/4"

50 - 30

20

1.4kg - 20g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

6.55

1.37 - 1.28

16 - 13.6

£658

£66

£1,097

£1,821

RAV-SM567CTP-E

RBC-AMS41E

RAV-SP564ATP-E

5.0 (1.2 - 5.6)

4.8 - 3.6

5.6 (0.9 - 7.4)

3.7

RAV-SM807CTP-E

RBC-AMS41E

RAV-SP804ATP-E

7.1 (1.9 - 8.0)

6.7 - 5.1

8.0 (1.3 - 10.6)

5.2

5.45 - 4.28

A / A+

3.65 - 4.38

A / A

6.21 - 4.10

A++ / A+

3.82 - 4.17

A / A

235 - 950 - 690

550 - 780 - 290

23 - 44

43°C to -15°C

15°C to -20°C

235 - 1270 - 690

890 - 900 - 320

29 - 66

150 - 200 - 250 n/a n/a

208 - 278 - 392 n/a n/a

29 - 36 - 41

48 - 49

5/8" - 3/8"

50 - 30

30

2.1kg - 40g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

9.02

1.86 - 1.92

25 - 20.6

£779

£66

£1,628

£2,473

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

63

RAV Split Systems

Ceiling Suspended Super Digital Inverter Single Phase

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

AMBIENT RANGE

Cooling

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

235 - 1586 - 690

1340 - 900 - 320

35 - 93

283 - 375 - 517 n/a n/a

32 - 38 - 44

49 - 50

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

10.43

2.45 - 2.39

25 - 21.6

£849

£66

£1,995

£2,910

RAV-SM1107CTP-E

RBC-AMS41E

RAV-SP1104AT-E

10.0 (2.6 - 12.0)

9.5 - 7.2

11.2 (2.4 - 13.0)

7.3

6.18 - 4.27

A++ / A+

4.08 - 4.69

A / A

43°C to -15°C

15°C to -20°C

RAV-SM1407CTP-E

RBC-AMS41E

RAV-SP1404AT-E

12.5 (2.6 - 14.0)

11.9 - 8.7

14.0 (2.4 - 18.0)

9.1

5.14 - 4.09

A / A+

3.21 - 3.87

A / A

235 - 1586 - 690

1340 - 900 - 320

35 - 93

333 - 425 - 567 n/a n/a

35 - 41 - 46

51 - 52

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP20 (20id 26od)

230 - 1 - 50

3 core + E

15.76

3.90 - 3.62

25 - 21.6

£1,071

£66

£2,205

£3,342

@amp_aircon | amp-air-conditioning 64

RAV Split Systems

Ceiling Suspended Super Digital Inverter Three Phase

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

UK Cooling (Total - Sensible)

Nominal Heating (Range)

UK Heating

SEER - SCOP (Cool - Heat)

Energy Efficiency Class (Cool / Heat)

EER - COP (Cool - Heat)

Energy Label (Cool / Heat)

Cooling

AMBIENT RANGE

Heating

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Indoor Unit Airflow Rate (l-m-h)

Static Pressure (standard-upper)

Discharge Spigots

Indoor Sound Pressure (l-m-h)

Outdoor Sound Pressure (cool-heat)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Indoor Drain Connection

Power Supply (Outdoor)

Interconnecting Cables

Running Current (Cool - Heat)

Power Consumption (Cool - Heat)

Suggested Fuse Size - Max. Current

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

A kW

A kW kW kW kW mm

V-Ph-Hz

°C

°C mm mm kg l/s

Pa m m kg dB(A) dB(A) in

RAV-SM1107CTP-E

RBC-AMS41E

RAV-SP1104AT8-E

10.0 (2.6 - 12.0)

9.5 - 7.2

11.2 (2.4 - 14.0)

7.3

6.35 - 4.41

A++ / A+

4.22 - 4.43

A / A

235 - 1586 - 690

1340 - 900 - 320

35 - 95

283 - 375 - 517 n/a n/a

32 - 38 - 44

49 - 50

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP20 (20id 26od)

400 - 3 - 50

3 core + E

3.72 per phase

2.53 - 2.37

20 - 16.1 per phase

£849

£66

£2,184

£3,099

35 - 41 - 46

51 - 52

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP20 (20id 26od)

400 - 3 - 50

3 core + E

5.42 per phase

3.56 - 3.72

20 - 15.9 per phase

£1,071

£66

£2,279

£3,416

RAV-SM1407CTP-E

RBC-AMS41E

RAV-SP1404AT8-E

12.5 (2.6 - 12.0)

11.9 - 8.7

14.0 (2.4 - 18.0)

9.1

5.49 - 4.65

A / A++

3.36 - 3.93

A / A

46°C to -15°C

15°C to -20°

235 - 1586 - 690

1340 - 900 - 320

35 - 95

333 - 425 - 567 n/a n/a

RAV-SM1607CTP-E

RBC-AMS41E

RAV-SP1604AT8-E

14.0 (2.6 - 16.0)

13.3 - 9.3

16.0 (2.4 - 19.0)

10.4

5.49 - 4.73

A / A++

3.11 - 3.71

B / A

235 - 1586 - 690

1340 - 900 - 320

35 - 95

350 - 458 - 567 n/a n/a

36 - 42 - 46

51 - 53

5/8" - 3/8"

75 - 30

30

3.1kg - 40g/m

Yes

VP20 (20id 26od)

400 - 3 - 50

3 core + E

6.66 per phase

4.31 - 4.50

20 - 16.1 per phase

£1,090

£66

£2,426

£3,582

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

65

RAV Split Systems

Floor Standing VRF Indoor Unit Conversions

It is now possible, utilising the RBC-CK1/CK2 interface, to convert floor standing VRF indoor units to connect to a standard RAV digital or super digital inverter outdoor unit. The interface fits to the indoor unit, with the unit shipped with interface fitted by AMP. It can then be connected to any of the standard RAV control options.

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Nominal Heating (Range)

Indoor Unit Dimensions (h-w-d)

Outdoor Unit Dimensions (h-w-d)

Weight (Indoor - Outdoor)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Power Supply (Outdoor)

Suggested Fuse Size

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

V-Ph-Hz

A kW kW mm mm kg in m

Floor Chassis

AMP-MML-AP0154BH-E AMP-MML-AP0184BH-E AMP-MML-AP0244BH-E

RBC-AMS41E

RAV-SM564ATP-E

RBC-AMS41E

RAV-SM564ATP-E

RBC-AMS41E

RAV-SM804ATP-E

5.0

5.3

600 - 1045 - 220

550 - 780 - 290

29 - 40

5.0

5.3

600 - 1045 - 220

550 - 780 - 290

29 - 40

6.7

7.7

600 - 1045 - 220

550 - 780 - 290

29 - 44

1/2" - 1/4"

30 - 30

230 - 1 - 50

16

£1,075

£66

£840

£1,981

1/2" - 1/4"

30 - 30

230 - 1 - 50

16

£1,130

£66

£840

£2,036

5/8" - 3/8"

30 - 30

230 - 1 - 50

20

£1,166

£66

£1,177

£2,409

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Nominal Heating (Range)

Indoor Unit Dimensions (H-W-D)

Outdoor Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Power Supply (Outdoor)

Suggested Fuse Size

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

V-Ph-Hz

A kW kW mm mm kg in m

Floor Chassis

Floor Cabinet

AMP-MML-AP0154H-E

RBC-AMS41E

RAV-SM564ATP-E

5.0

5.3

630 - 950 - 230

550 - 780 - 290

37 - 44

1/2" - 1/4"

30 - 30

230 - 1 - 50

16

£1,243

£66

£840

£2,149

AMP-MML-AP0184H-E

RBC-AMS41E

RAV-SM564ATP-E

5.0

5.3

630 - 950 - 230

550 - 780 - 290

40 - 44

1/2" - 1/4"

30 - 30

230 - 1 - 50

16

£1,306

£66

£840

£2,212

AMP-MML-AP0244H-E

RBC-AMS41E

RAV-SM804ATP-E

6.7

7.7

630 - 950 - 230

550 - 780 - 290

40 - 44

5/8" - 3/8"

30 - 30

230 - 1 - 50

20

£1,352

£66

£1,177

£2,595

Indoor unit cost includes RBC-CK1 and fitting ready for installation

Units can also be used for twin split systems, contact AMP for details

Can be used on replacement technology

Can also be used with super digital outdoor units

Floor Cabinet

@amp_aircon | amp-air-conditioning 66

RAV Split Systems

Floor Standing VRF Indoor Unit Conversions

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Nominal Heating (Range)

Indoor Unit Dimensions (h-w-d)

Outdoor Unit Dimensions (h-w-d)

Weight (Indoor - Outdoor)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Power Supply (Outdoor)

Suggested Fuse Size

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

V-Ph-Hz

A kW kW mm mm kg in m

AMP-MMF-AP0156H-E

RBC-AMS41E

RAV-SM564ATP-E

5.0

5.3

1750 - 600 - 210

550 - 780 - 290

46 - 40

1/2" - 1/4"

30 - 30

230 - 1 - 50

16

£1,539

£66

£840

£2,445

AMP-MMF-AP0246H-E

RBC-AMS41E

RAV-SM804ATP-E

6.7

7.7

1750 - 600 - 210

550 - 780 - 290

47 - 44

5/8" - 3/8"

30 - 30

230 - 1 - 50

20

£1,680

£66

£1,177

£2,923

AMP-MMF-AP0276H-E

RBC-AMS41E

RAV-SM804ATP-E

6.7

7.7

1750 - 600 - 210

550 - 780 - 290

47 - 44

5/8" - 3/8"

30 - 30

230 - 1 - 50

20

£1,723

£66

£1,177

£2,966

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Nominal Heating (Range)

Indoor Unit Dimensions (h-w-d)

Outdoor Unit Dimensions (h-w-d)

Weight (Indoor - Outdoor)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Power Supply (Outdoor)

Suggested Fuse Size

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

kW kW mm mm kg in m

V-Ph-Hz

A

AMP-MMF-AP0366H-E

RBC-AMS41E

RAV-SM1104ATP-E

10.0

11.2

1750 - 600 -390

890 - 900 - 320

62 - 68

5/8" - 3/8"

50 - 30

230 - 1 - 50

25

£1,767

£66

£1,549

£3,382

AMP-MMF-AP0486H-E

RBC-AMS41E

RAV-SM1404ATP-E

12.1

12.8

1750 - 600 -390

890 - 900 - 320

62 - 68

5/8" - 3/8"

50 - 30

230 - 1 - 50

25

£1,845

£66

£1,633

£3,544

AMP-MMF-AP0566H-E

RBC-AMS41E

RAV-SM1603AT-E

14.0

16.0

1750 - 600 -390

1340 - 900 - 320

62 - 99

5/8" - 3/8"

50 - 30

230 - 1 - 50

32

£1,925

£66

£2,059

£4,050

Indoor unit cost includes RBC-CK1 and fitting ready for installation

Units can also be used for twin split systems, contact AMP for details

Can be used on replacement technology

ampair.co.uk | 01707 378 670 | [email protected]

67

RAV Split Systems

Floor Standing VRF Indoor Unit Conversions

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Nominal Heating (Range)

Indoor Unit Dimensions (h-w-d)

Outdoor Unit Dimensions (h-w-d)

Weight (Indoor - Outdoor)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Power Supply (Outdoor)

Suggested Fuse Size

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

m

V-Ph-Hz

A kW kW mm mm kg in

AMP-MMF-AP0156H-E

RBC-AMS41E

RAV-SP564ATP-E

5.0

5.3

1750 - 600 - 210

550 - 780 - 290

46 - 44

1/2" - 1/4"

50 - 30

230 - 1 - 50

16

£1,539

£66

£1,097

£2,702

AMP-MMF-AP0246H-E

RBC-AMS41E

RAV-SP804ATP-E

6.7

7.7

1750 - 600 - 210

890 - 900 - 320

47 - 66

5/8" - 3/8"

50 - 30

230 - 1 - 50

25

£1,680

£66

£1,628

£3,374

AMP-MMF-AP0276H-E

RBC-AMS41E

RAV-SP804ATP-E

6.7

7.7

1750 - 600 - 210

890 - 900 - 320

47 - 66

5/8" - 3/8"

50 - 30

230 - 1 - 50

25

£1,723

£66

£1,628

£3,417

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Nominal Cooling (Range)

Nominal Heating (Range)

Indoor Unit Dimensions (h-w-d)

Outdoor Unit Dimensions (h-w-d)

Weight (Indoor - Outdoor)

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Power Supply (Outdoor)

Suggested Fuse Size

Indoor Unit

Remote Controller inc. Time Clock

Outdoor Unit

Retail Price

V-Ph-Hz

A kW kW mm mm kg in m

AMP-MMF-AP0366H-E

RBC-AMS41E

RAV-SP1104AT-E

10.0

11.2

1750 - 600 -390

1340 - 900 - 320

62 - 93

5/8" - 3/8"

75 - 30

230 - 1 - 50

25

£1,767

£66

£1,995

£3,828

AMP-MMF-AP0486H-E

RBC-AMS41E

RAV-SP1404AT-E

12.1

12.8

1750 - 600 -390

1340 - 900 - 320

62 - 93

5/8" - 3/8"

75 - 30

230 - 1 - 50

25

£1,845

£66

£2,205

£4,116

AMP-MMF-AP0566H-E

RBC-AMS41E

RAV-SP1604AT8-E

14.0

16.0

1750 - 600 -390

1340 - 900 - 320

62 - 95

5/8" - 3/8"

75 - 30

400 - 3 - 50

20A per phase

£1,925

£66

£2,426

£4,417

Indoor unit cost includes RBC-CK1 and fitting ready for installation

Units can also be used for twin split systems, contact AMP for details

Can be used on replacement technology

@amp_aircon | amp-air-conditioning 68

Very helpful and responsive when dealing with technical matters and on-site equipment issues. Always nice to know that back up is there when its needed most.”

Glen Tempest - NCPI Solutions

Photo: Mickey Day, Warehouse Operative at AMP

ampair.co.uk | 01707 378 670 | [email protected]

69

RAV Split Systems

Digital Inverter Twin Split Systems

Outdoor

Unit

-

Phase

-

Range -

Refrigerant

Nom.

Cool/Heat

-

Rmt. Control

-

Branch Pipe

Indoor

Units

RAV-

SM564ATP-E

5.0 / 5.3

Single Phase RBC-AMS41E

DI - R410A

RAV-

SM804ATP-E

n/a

6.7 / 7.7

Single Phase RBC-AMS41E

DI - R410A n/a

RAV-

SM1104ATP-E

10.0 / 11.2

Single Phase RBC-AMS41E

DI - R410A n/a

RAV-

SM1404ATP-E

12.1 / 12.8

Single Phase RBC-AMS41E

DI - R410A

RAV-

SM1603AT-E

n/a

14.0 / 16.0

Single Phase RBC-AMS41E

DI - R410A

RAV-

SM2244AT8-E

n/a

20.0 / 22.4

Three Phase RBC-AMS41E

DI - R410A

RAV-

SM2804AT8-E

RBC-TWP101E

23.0 / 27.0

Three Phase RBC-AMS41E

DI - R410A RBC-TWP101E

2 x 30*

2 x 40*

2 x 56*

2 x 80*

2 x 80*

2 x 110*

2 x 140*

KRTP-E

Wall

Mounted

CTP-E

Ceiling

Suspended

MUT-E

Compact

Cassette

UTP-E

4 Way

Cassette

SDT-E

Slim

Ducted

BTP-E

Standard

Ducted

Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price

SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP

Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating

£1,490.00

£2,382.00

£1,840.00

5.77

4.00

A+ A

5.48

A

4.16

A+

5.06

B

4.06

A+

£1,877.00

5.62

4.01

A+ A+

£2,397.00

A+ A+

£2,931.00

A+ A+

£3,067.00

A A+

£2,651.00

B A

£2,871.00

5.13

4.18

5.70

4.27

£3,143.00

5.04

4.17

5.72

4.28

5.09

4.16

5.00

4.14

A A+

£2,541.00

£2,451.00

5.62

4.01

A+ A+

£3257.00

£2,707.00

5.81

B

4.05

A+ A+ A+

£3,423.00

£2,257.00

£2,379.00

5.58

4.07

5.04

3.83

B A+ B A+

£3,493.00

5.27

A

4.19

A+

5.53

A

4.55

A+

5.25

4.19

A A+

5.53

4.42

A A+

£2,967.00

£3,683.00

4.94

4.36

4.94

B A+ B

4.36

A+

£3,849.00

5.47

4.47

A A+

£3,919.00

4.78

3.86

B A

£4,764.00

4.76

4.54

B A+

£5,303.00

4.85

4.31

B A+

£4,960.00

5.01

4.79

B A++

£5,099.00

5.15

4.55

A A+

£5,128.00

4.76

4.54

B A+

£5,447.00

4.85

4.31

B A+

@amp_aircon | amp-air-conditioning 70

RAV Split Systems

Digital Inverter Twin Split Systems

Outdoor Unit Details & Pipe Sizing

Outdoor unit

RAV-SM564ATP-E

RAV-SM804ATP-E

RAV-SM1104ATP-E

RAV-SM1404ATP-E

RAV-SM1603AT-E

RAV-SM2244AT8-E

RAV-SM2804AT8-E

Maximum pipe run

(Height difference)

30m - 30m

30m - 30m

50m - 30m

50m - 30m

50m - 30m

70m - 30m

70m - 30m

Indoor Unit Pipe Sizing

Indoor unit

30*

40*

56*

80*

110*

140*

Pipe Sizes

3/8" & 1/4"

1/2" & 1/4"

1/2" & 1/4"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values.

| System costs include all branch kits and spigot kits (where required) and 1 x RBC-

AMS41E remote controller.

Pipe Sizes

1/2" & 1/4"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

1 1/8" & 1/2"

1 1/8" & 1/2"

Suggested Fuse Size

16A

20A

25A

25A

32A

25A per phase

32A per phase

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

71

RAV Split Systems

Super Digital Inverter Twin Split Systems

Outdoor

Unit

-

Phase

-

Range -

Refrigerant

Nom.

Cool/Heat

-

Rmt. Control

-

Branch Pipe

Indoor

Units

RAV-

SP564ATP-E

5.0 / 5.6

Single Phase RBC-AMS41E

SDI - R410A

RAV-

SP804ATP-E

n/a

7.1 / 8.0

Single Phase RBC-AMS41E

SDI - R410A n/a

RAV-

SP1104ATP-E

10.0 / 11.2

Single Phase RBC-AMS41E

SDI - R410A n/a

RAV-

SP1104AT8-E

10.0 / 11.2

Three Phase RBC-AMS41E

SDI - R410A

RAV-

SP1404AT-E

n/a

12.3 / 14.0

Single Phase RBC-AMS41E

SDI - R410A

RAV-

SP1404AT8-E

n/a

12.3 / 14.0

Three Phase RBC-AMS41E

SDI - R410A RBC-TWP101E

RAV-

SP1604AT8-E

14.0 / 16.0

Three Phase RBC-AMS41E

SDI - R410A RBC-TWP101E

2 x 30*

2 x 40*

2 x 56*

2 x 56*

2 x 80*

2 x 80*

2 x 80*

KRTP-E

Wall

Mounted

CTP-E

Ceiling

Suspended

MUT-E

Compact

Cassette

UTP-E

4 Way

Cassette

SDT-E

Slim

Ducted

BTP-E

Standard

Ducted

Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price

SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP

Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating

£1,747.00

£2,639.00

£2,097.00

5.82

4.01

A+ A+

5.61

A+

4.20

A+

5.10

A

3.90

A

£2,328.00

£2,902.00

5.88

3.87

6.21

4.10

£3,158.00

5.60

3.86

£2,708.00

£2,830.00

5.38

3.88

5.88

4.00

A+ A

£2,843.00

A++ A+

£3,377.00

A+ A

£3,513.00

A A

£3,097.00

A+ A+

£3,317.00

5.60

3.87

6.18

£3,589.00

4.27

5.67

3.90

6.60

4.28

5.60

3.84

5.65

3.87

A+ A

£3,032.00

A++ A+

£3,566.00

A+ A

£3,702.00

A++ A+

£3,778.00

A+ A

£3,286.00

A+ A

£3,506.00

5.51

3.87

6.35

4.41

5.64

3.90

6.57

4.28

5.55

3.84

5.65

3.87

A A A++ A+ A+ A A++ A+ A A A+ A

£3,113.00

B A

£3,829.00

4.95

4.00

5.14

A

4.09

A+

£3,187.00

£3,903.00

4.95

4.00

5.49

4.65

B A

£3,334.00

A A++

£4,050.00

4.55

3.64

5.49

4.73

C A A A++

£3,995.00

6.18

4.61

A++ A++

£4,069.00

5.87

4.86

A+ A++

£4,216.00

5.49

4.73

A+ A++

£4,065.00

5.22

4.03

A A+

£4,139.00

5.09

4.48

B A+

£4,286.00

4.97

4.35

B A+

@amp_aircon | amp-air-conditioning 72

RAV Split Systems

Super Digital Inverter Twin Split Systems

Outdoor Unit Details & Pipe Sizing

Outdoor Unit

RAV-SP564ATP-E

RAV-SP804ATP-E

RAV-SP1104ATP-E

RAV-SP1104AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1604AT8-E

Maximum pipe run

(Height difference)

50m - 30m

50m - 30m

75m - 30m

75m - 30m

75m - 30m

75m - 30m

75m - 30m

Indoor Unit Pipe Sizing

Indoor unit

30*

40*

56*

80*

Pipe Sizes

3/8" & 1/4"

1/2" & 1/4"

1/2" & 1/4"

5/8" & 3/8"

Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |

System costs include all branch kits and spigot kits (where required) and

1 x RBC-AMS41E remote controller.

Pipe Sizes

1/2" & 1/4"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

Suggested Fuse Size

16A

25A

25A

20A per phase

25A

20A per phase

20A per phase

Toshiba Rewards, the new loyalty scheme from

Toshiba, see page 207 for details

ampair.co.uk | 01707 378 670 | [email protected]

73

RAV Split Systems

Digital Inverter Triple Split Systems

Outdoor

Unit

-

Phase

-

Range -

Refrigerant

Nom.

Cool/Heat

-

Rmt. Control

-

Branch Pipe

Indoor

Units

RAV-

SM1104ATP-E

10.0 / 11.2

Single Phase RBC-AMS41E

DI - R410A

RAV-

SM1404ATP-E

RBC-TRP100E

12.1 / 12.8

Single Phase RBC-AMS41E

DI - R410A RBC-TRP100E

RAV-

SM1603AT-E

14.0 / 16.0

Single Phase RBC-AMS41E

DI - R410A RBC-TRP100E

RAV-

SM2244AT8-E

20.0 / 22.4

Three Phase RBC-AMS41E

DI - R410A

RAV-

SM2804AT8-E

RBC-TRP100E

23.0 / 27.0

Three Phase RBC-AMS41E

DI - R410A RBC-TRP100E

3 x 30*

3 x 40*

3 x 56*

3 x 80*

3 x 80*

KRTP-E

Wall

Mounted

CTP-E

Ceiling

Suspended

MUT-E

Compact

Cassette

UTP-E

4 Way

Cassette

SDT-E

Slim

Ducted

BTP-E

Standard

Ducted

Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price

SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP

Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating

£2,667.00

£4,025.00

£3,212.00

5.70

4.27

A+ A+

5.04

B

4.17

A+

5.09

B

4.16

A+

£2,846.00

5.53

4.55

A A+

£3,494.00

A A+

£4,295.00

A A+

£4,499.00

A A+

£3,875.00

4.54

3.39

£4,613.00

£4,205.00

4.94

4.36

4.64

3.86

5.47

4.47

4.64

3.86

4.78

3.86

C B

£4,525.00

£3,707.00

5.53

4.55

B A+

£5,599.00

£4,091.00

5.25

B

4.19

A A A+

£5,848.00

£3,416.00

5.53

4.42

B A B A

£5,953.00

4.76

B

4.54

A+

4.76

B

4.54

A+

5.01

4.79

B A++

4.76

4.54

B A+

£4,620.00

4.85

B

4.31

A+

£5,694.00

4.85

4.31

B A+

£5,943.00

5.15

4.55

A A+

£6,048.00

4.85

4.31

B A+

@amp_aircon | amp-air-conditioning 74

RAV Split Systems

Digital Inverter Triple Split Systems

Outdoor Unit Details & Pipe Sizing

Outdoor unit

RAV-SM1104ATP-E

RAV-SM1404ATP-E

RAV-SM1603AT-E

RAV-SM2244AT8-E

RAV-SM2804AT8-E

Indoor Unit Pipe Sizing

Indoor unit

30*

40*

56*

80*

Maximum pipe run

(Height difference)

50m - 30m

50m - 30m

50m - 30m

70m - 30m

70m - 30m

Pipe Sizes

3/8" & 1/4"

1/2" & 1/4"

1/2" & 1/4"

5/8" & 3/8"

Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |

System costs include all branch kits and spigot kits (where required) and

1 x RBC-AMS41E remote controller.

Pipe Sizes

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

1 1/8" & 1/2"

1 1/8" & 1/2"

Suggested Fuse Size

25A

25A

32A

25A per phase

32A per phase

ampair.co.uk | 01707 378 670 | [email protected]

75

RAV Split Systems

Super Digital Inverter Triple Split Systems

Outdoor

Unit

-

Phase

-

Range -

Refrigerant

Nom.

Cool/Heat

-

Rmt. Control

-

Branch Pipe

Indoor

Units

RAV-

SP1104ATP-E

10.0 / 11.2

Single Phase RBC-AMS41E

SDI - R410A RBC-TRP100E

RAV-

SP1104AT8-E

10.0 / 11.2

Three Phase RBC-AMS41E

SDI - R410A RBC-TRP100E

RAV-

SP1404AT-E

12.3 / 14.0

Single Phase RBC-AMS41E

SDI - R410A RBC-TRP100E

RAV-

SP1404AT8-E

12.3 / 14.0

Three Phase RBC-AMS41E

SDI - R410A RBC-TRP100E

RAV-

SP1604AT8-E

14.0 / 16.0

Three Phase RBC-AMS41E

SDI - R410A RBC-TRP100E

3 x 30*

3 x 30*

3 x 40*

3 x 40*

3 x 56*

KRTP-E

Wall

Mounted

CTP-E

Ceiling

Suspended

MUT-E

Compact

Cassette

UTP-E

4 Way

Cassette

SDT-E

Slim

Ducted

BTP-E

Standard

Ducted

Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price

SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP

Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating

£3,133.00

£4,471.00

£3,652.00

5.60

3.87

A+ A

5.67

A+

3.90

A

5.60

A+

3.84

A

£3,322.00

5.51

A

3.87

A

£3,418.00

4.95

4.00

£4,279.00

£4,660.00

5.64

A+

3.90

A

£4,663.00

5.14

4.09

6.18

4.61

£3,847.00

5.55

3.84

A A

£3,988.00

B

4.95

B

A

£3,492.00

4.00

A

A

£4,353.00

5.49

A

A+

4.65

A++

A++

£4,737.00

5.87

A+

A++

4.86

A++

5.22

4.03

A A+

£4,062.00

5.09

4.48

B A+

£3861.00

£4,662.00

4.55

3.64

5.49

4.73

£4,866.00

4.95

4.65

£4,980.00

5.49

4.73

£4,242.00

4.95

4.43

£4,572.00

4.97

4.35

C A A A++ B A+ A A++ B A+ B A+

@amp_aircon | amp-air-conditioning 76

RAV Split Systems

Super Digital Inverter Triple Split Systems

Outdoor Unit Details & Pipe Sizing

Outdoor unit

RAV-SP1104ATP-E

RAV-SP1104AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1604AT8-E

Indoor Unit Pipe Sizing

Maximum pipe run

(Height difference)

75m - 30m

75m - 30m

75m - 30m

75m - 30m

75m - 30m

Indoor unit

30*

40*

56*

Pipe Sizes

3/8" & 1/4"

1/2" & 1/4"

1/2" & 1/4"

Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |

System costs include all branch kits and spigot kits (where required) and

1 x RBC-AMS41E remote controller.

Pipe Sizes

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

Suggested Fuse Size

25A

20A per phase

25A

20A per phase

20A per phase

ampair.co.uk | 01707 378 670 | [email protected]

77

RAV Split Systems

Digital Inverter & Super Digital Inverter Quad Split Systems

Outdoor

Unit

-

Phase

-

Range -

Refrigerant

Nom.

Cool/Heat

-

Rmt. Control

-

Branch Pipe

Indoor

Units

RAV-

SM1404ATP-E

12.1 / 12.8

Single Phase RBC-AMS41E

DI - R410A

RBC-

DTWP101E

RAV-

SP1404AT-E

12.3 / 14.0

Single Phase RBC-AMS41E

SDI - R410A

RBC-

DTWP101E

RAV-

SP1404AT8-E

12.3 / 14.0

Three Phase RBC-AMS41E

SDI - R410A

RBC-

DTWP101E

RAV-

SM1603AT-E

14.0 / 16.0

Single Phase RBC-AMS41E

DI - R410A

RAV-

SP1604AT8-E

RBC-

DTWP101E

14.0 / 16.0

Three Phase RBC-AMS41E

SDI - R410A

RBC-

DTWP101E

RAV-

SM2244AT8-E

20.0 / 22.4

Three Phase RBC-AMS41E

DI - R410A

RBC-

DTWP101E

RAV-

SM2804AT8-E

23.0 / 27.0

Three Phase RBC-AMS41E

DI - R410A

RBC-

DTWP101E

4 x 30*

4 x 30*

4 x 30*

4 x 40*

4 x 40*

4 x 56*

4 x 80*

KRTP-E

Wall

Mounted

CTP-E

Ceiling

Suspended

MUT-E

Compact

Cassette

UTP-E

4 Way

Cassette

SDT-E

Slim

Ducted

BTP-E

Standard

Ducted

Retail Price Retail Price Retail Price Retail Price Retail Price Retail Price

SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP SEER SCOP

Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating Eng. Rating

£3,076.00

£4,860.00

£3,776.00

5.53

4.55

A A+

5.25

A

4.19

A+

5.53

A

4.42

A+

£3,648.00

4.95

4.00

B A

£3,722.00

£5,432.00

6.18

A++

4.61

A++

£5,506.00

£4,348.00

5.22

A

4.03

A+

£4,422.00

4.95

4.00

B A

5.87

4.86

A+ A++

£3,602.00

£4,750.00

4.54

3.39

4.94

4.36

£5,262.00

4.64

3.86

C B B A+ B A

5.09

4.48

B A+

£4,362.00

£4,606.00

4.64

3.86

4.64

3.86

B A B A

£3,969.00

£5,117.00

4.55

3.64

5.49

C A A

4.73

A++

£5,629.00

5.49

A

4.73

A++

£4,729.00

£4,973.00

4.95

4.43

4.95

4.43

B A+ B A+

£4,836.00

£5,907.00

4.76

4.54

4.76

4.54

£6,179.00

4.76

4.54

£6,331.00

5.01

4.79

£5,347.00

4.76

4.54

£5,787.00

4.76

4.54

B A+ B A+ B A+

£5,054.00

B A+

£6,486.00

B A++

£6,818.00

B A+

£6,902.00

4.85

4.31

4.85

4.31

B A+ B A+

5.15

4.55

A A+

4.85

4.31

B A+

@amp_aircon | amp-air-conditioning 78

RAV Split Systems

Digital Inverter & Super Digital Inverter Quad Split Systems

Outdoor Unit Details & Pipe Sizing

Outdoor unit

RAV-SM1404ATP-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SM1603AT-E

RAV-SP1604AT8-E

RAV-SM2244AT8-E

RAV-SM2804AT8-E

Indoor Unit Pipe Sizing

Indoor unit

30*

40*

56*

80*

Maximum pipe run

(Height difference)

50m - 30m

75m - 30m

75m - 30m

50m - 30m

75m - 30m

70m - 30m

70m - 30m

Pipe Sizes

3/8" & 1/4"

1/2" & 1/4"

1/2" & 1/4"

5/8" & 3/8"

Units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please refer to technical data for exact values. |

System costs include all branch kits and spigot kits (where required) and

1 x RBC-AMS41E remote controller.

Pipe Sizes

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

5/8" & 3/8"

1 1/8" & 1/2"

1 1/8" & 1/2"

Suggested Fuse Size

25A

25A

20A per phase

32A

20A per phase

25A per phase

32A per phase

ampair.co.uk | 01707 378 670 | [email protected]

Optional Controller

RBC-AMS54E-ES £105 Retail

79

“AMP have been our preferred supplier for many years due to their outstanding product knowledge, excellent service and friendly staff, they are our “go to” A/C Supplier”

Kevin Efford - Complete Cooling Systems limited

Photo: Tim Young, Commercial Manager at AMP

VRF Systems

VRF Outdoor

Introduction

VRF technology offers the best solution for large commercial and industrial buildings, including hotels, hospitals, leisure and shopping centers.

The dual / triple inverter compressors guarantee high efficiency levels, operating flexibility and reduced maintenance requirements. Moreover, the wide range of indoor units make the Toshiba VRF system the most flexible choice to satisfy any kind of requirement and is ideal for many installations.

Quality has always been Toshiba’s strength and will remain the trademark that will differentiate

Toshiba air conditioners from the competition.

This is the philosophy behind every Toshiba product especially in the highly technological

VRF systems where the use of the active oil management system and inverter controlled compressors, provide a significant reduction in mechanical and electrical stress, increasing the durability and reliability of the components.

With the sophisticated Toshiba technology and the use of 3 compressors and 3 inverters, the SMMSe systems ensure extraordinary flexibility in any application. The SMMSe offers innovations in energy savings with highly efficient DC twin rotary compressors and advanced vector-controlled inverters boasting higher COP at 50% partial load.

The new Toshiba three-pipe VRF Super Heat

Recovery Multi System (SHRMi) delivers simultaneous cooling and heating to different zones or rooms and has exceptional energy efficiency.

The Toshiba MiNi-SMMS is a small VRF system which offers great flexibility and power, but with a small and compact chassis which bridges the gap between the versatile Multi-Split Systems and the larger capacity of the SMMSe.

Sophisticated inverter control permits matching of the actual refrigerant flow to the capacity required by each indoor unit in an application.

This results in optimised efficiency of the refrigerant cycle and increased precision in maintaining the required temperature, improving comfort for the occupants.

@amp_aircon | amp-air-conditioning 82

VRF Outdoor

Range Overview

84

Nominal Cooling kW

Nominal Heating kW

Outdoor Unit Type

Capacity Code (Hp)

2 pipe Mini SMMS - heat pump

12.1 14.0 15.5 22.4 28.0 33.5 40.0 45.0 50.4 56.0 61.5 68.0 73.0 78.5 85.0

12.5 16.0 18.0 25.0 31.5 37.5 45.0 50.0 56.5 63.0 69.0 76.5 81.5 88.0 95.0

04** 05** 06** 08** 10** 12** 14** 16** 18** 20** 22** 24** 26** 28** 30**

4 5 6 8 10 12 14 16 18 20 22 24 26 28 30

ü ü ü

85 2 pipe SMMSe - heat pump n/a

Contact

AMP

2 pipe SMMSe - heat pump high efficiency

95 3 pipe SHRMi - heat recovery

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

84

Nominal Cooling kW

Nominal Heating kW

Outdoor Unit Type

Capacity Code (Hp)

2 pipe Mini SMMS - heat pump

90.0 96.0 101.0 106.0 112.0 118.0 123.5 130.0 135.0 140.4 146.0 151.5 157.0 162.5 168.0

100.0 108.0 113.0 119.5 127.0 132.0 138.0 145.0 150.0 156.0 163.0 164.0 176.0 177.0 178.0

32** 34** 36** 38** 40** 42** 44** 46** 48** 50** 52** 54** 56** 58** 60**

32 34 36 38 40 42 44 46 48 50 52 54 56 58 60

85 2 pipe SMMSe - heat pump n/a

Contact

AMP

2 pipe SMMSe - heat pump high efficiency

ü ü ü ü ü ü ü ü ü ü ü ü ü ü ü

ü ü ü ü ü ü

95 3 pipe SHRMi - heat recovery

ü ü ü ü ü ü

ampair.co.uk | 01707 378 670 | [email protected]

83

VRF Outdoor

Mini SMMS Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Retail Price

kW kW l/s

Pa in in in kg

HP mm mm mm kg dB(A)

V-Ph-Hz

A kW

A

A

1616

0

5/8"

3/8" n/a

7.2

230- 1 -50

20

2.82 - 2.71

13.2 - 12.5

Soft Start

£3,575

MCY-MAP0401HT n/a

4

12.1

12.5

6

3.2 - 5.2

4.29 - 4.61

7.09 - 7.39

5.86 - 6.09

1

4HP

1340

900

320

117

49.0 - 50.0

MCY-MAP0501HT n/a

5

14.0

16.0

8

4.0 - 6.5

4.03 - 4.00

6.45 - 6.73

5.07 - 5.26

1

5HP

1340

900

320

117

50.0 - 52.0

1700

0

5/8"

3/8" n/a

7.2

230- 1 -50

25

3.47 - 4.00

16.1 - 18.3

Soft Start

£4,064

1783

0

3/4"

3/8" n/a

7.2

230- 1 -50

32

4.63 - 4.85

21.4 - 22.2

Soft Start

£4,369

MCY-MAP0601HT n/a

6

15.5

18.0

9

4.3 - 7.8

3.35 - 3.71

5.51 - 5.76

5.14 - 5.37

1

6HP

1340

900

320

117

51.0 - 53.0

For pipe work limitations see installation manual | 2 core non polar 1.5mm2 screened cable | **Condition apply, see technical manual for details

@amp_aircon | amp-air-conditioning 84

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-MAP0806HT8P-E MMY-MAP1006HT8P-E MMY-MAP1206HT8P-E n/a

8

22.4

n/a

10

28.0

n/a

12

33.5

25.0

18

4.00 - 10.8

4.04 - 4.52

31.5

22

5.0 - 13.5

3.64 - 4.25

37.5

27

6.0 - 16.2

3.35 - 3.89

7.18 - 7.55

5.71 - 5.95

1

8HP

1830

990

780

242

55.0 - 56.0

7.04 - 7.45

5.45 - 5.69

1

10HP

1830

990

780

242

57.0 - 58.0

7.23 - 7.72

5.05 - 5.29

1

12HP

1830

990

780

242

59.0 - 61.0

2694

60

3/4"

1/2" na

11.5

400 - 3 - 50

TBC

5.54 - 5.53

8.79 - 8.77

soft start

£6,003

2694

60

7/8"

1/2" na

11.5

400 - 3 - 50

TBC

7.69 - 7.41

12.1 - 11.6

soft start

£6,574

3389

50

1 1/8"

1/2" na

11.5

400 - 3 - 50

TBC

10.0 - 9.65

15.5 - 15.0

soft start

£7,302

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

85

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-MAP1406HT8P-E MMY-MAP1606HT8P-E MMY-MAP1806HT8P-E n/a

14

40.0

n/a

16

45.0

n/a

18

50.4

45.0

31

7.0 - 19.9

3.25 - 4.02

50.0

36

8.0 - 21.6

3.15 - 3.88

56.5

40

9.0 - 24.3

3.45 - 3.97

6.96 - 7.42

5.08 - 5.29

1

14HP

1830

1210

780

300

60.0 - 62.0

7.09 - 7.59

4.86 - 5.07

1

16HP

1830

1210

780

300

62.0 - 64.0

6.83 - 7.25

4.99 - 5.20

1

18HP

1830

1600

780

371

60.0 - 61.0

3389

50

1 1/8"

5/8" na

11.5

400 - 3 - 50

TBC

12.3 - 11.2

19.5 - 17.8

Soft Start

£9,132

3500

40

1 1/8"

5/8" na

11.5

400 - 3 - 50

TBC

14.3 - 12.9

22.4 - 20.2

Soft Start

£9,509

4805

50

1 1/8"

5/8" na

11.5

400 - 3 - 50

TBC

14.6 - 14.1

22.9 - 22.1

Soft Start

£10,460

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

SMMSe Hi COP combinations also available.

Contact AMP for more information.

@amp_aircon | amp-air-conditioning 86

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-MAP2006HT8P-E n/a

20

56.0

63.0

45

10.0 - 27.0

3.24 - 3.71

6.73 - 7.17

4.73 - 4.95

1

20HP

1830

1600

780

371

61.0 - 62.0

4972

40

1 1/8"

5/8" na

11.5

400 - 3 - 50

TBC

17.3 - 17.0

26.8 - 26.1

Soft Start

£11,192

MMY-AP2206HT8P-E n/a

22

61.5

64.0

49

11.0 - 29.7

2.65 - 3.74

6.61 - 7.11

4.76 - 4.98

1

22HP

1830

1600

780

371

61.0 - 62.0

5139

40

1 1/8"

3/4" na

11.5

400 - 3 - 50

TBC

23.2 - 17.1

35.6 - 26.5

Soft Start

£11,975

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

87

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-AP2416HT8P-E

RBM-BT14E

24

67.0

75.0

54

12.0 - 32.4

3.35 - 3.89

7.22 - 7.71

5.08 - 5.31

2

12HP+12HP

1830

2000

780

484

62.0 - 64.0

6778

50

1 3/8"

3/4" na

23

400 - 3 - 50

TBC

20.0 - 19.3

31.0 - 30.0

Soft Start

£14,604

£127

£14,731

MMY-AP2616HT8P-E

RBM-BT24E

26

73.5

82.5

58

13.0 - 35.1

3.30 - 3.96

7.09 - 7.56

5.07 - 5.29

2

14HP+12HP

1830

2220

780

542

62.5 - 64.5

6778

50

1 3/8"

3/4" na

23

400 - 3 - 50

TBC

22.3 - 20.9

35.0 - 32.8

Soft Start

£16,434

£158

£16,592

6889

40

1 3/8"

3/4" na

23

400 - 3 - 50

TBC

24.3 - 22.6

37.9 - 35.2

Soft Start

£16,811

£158

£16,969

MMY-AP2816HT8P-E

RBM-BT24E

28

78.5

87.5

63

14.0 - 37.8

3.23 - 3.88

7.14 - 7.63

4.96 - 5.18

2

16HP+12HP

1830

2220

780

542

64.0 - 66.0

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

SMMSe Hi COP combinations also available.

Contact AMP for more information.

@amp_aircon | amp-air-conditioning 88

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-AP3016HT8P-E

RBM-BT24E

30

85.0

95.0

64

15.0 - 40.5

3.20 - 3.94

7.02 - 7.50

4.96 - 5.17

2

16HP+14HP

1830

2440

780

600

64.5 - 66.5

6889

40

1 3/8"

3/4" na

23

400 - 3 - 50

TBC

26.6 - 24.1

41.9 - 38.0

Soft Start

£18,641

£158

£18,799

MMY-AP3216HT8P-E

RBM-BT24E

32

90.0

100.0

64

16.0 - 43.2

3.15 - 3.88

7.08 - 7.57

4.86 - 5.07

2

16HP+16HP

1830

2440

780

600

65.0 - 67.0

7000

40

1 3/8"

3/4" na

23

400 - 3 - 50

TBC

28.6 - 25.8

44.8 - 40.4

Soft Start

£19,018

£158

£19,176

8305

40

1 3/8"

3/4" na

23

400 - 3 - 50

TBC

28.9 - 27.0

45.3 - 42.3

Soft Start

£19,969

£158

£20,127

MMY-AP3416HT8P-E

RBM-BT24E

34

95.4

106.0

64

17.0 - 45.9

3.30 - 3.93

6.96 - 7.41

4.93 - 5.14

2

18HP+16HP

1830

2830

780

671

64.5 - 66.0

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

89

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-AP3616HT8P-E

RBM-BT24E

36

101.0

113.0

64

18.0 - 48.6

3.20 - 3.78

6.90 - 7.36

4.79 - 5.00

2

20HP+16HP

1830

2830

780

671

64.5 - 66.5

8472

40

1 5/8"

7/8" n/a

23

400 - 3 - 50

TBC

31.6 - 29.9

49.2 - 46.3

Soft Start

£20,701

£158

£20,859

MMY-AP3816HT8P-E

RBM-BT24E

38

106.5

114.0

64

19.0 - 51.3

2.84 - 3.80

6.83 - 7.33

4.80 - 5.01

2

22HP+16HP

1830

2830

780

671

64.5 - 66.5

8639

40

1 5/8"

7/8" n/a

23

400 - 3 - 50

TBC

37.5 - 30.0

58.0 - 46.7

Soft Start

£21,484

£158

£21,642

9944

40

1 5/8"

7/8" n/a

23

400 - 3 - 50

TBC

34.6 - 34.0

53.6 - 52.2

Soft Start

£22,384

£158

£22,542

MMY-AP4016HT8P-E

RBM-BT24E

40

112.0

126.0

64

20.0 - 54.0

3.24 - 3.71

6.74 - 7.17

4.73 - 4.95

2

20HP+20HP

1830

3220

780

742

64.0 - 65.0

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

SMMSe Hi COP combinations also available.

Contact AMP for more information.

@amp_aircon | amp-air-conditioning 90

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-AP4216HT8P-E

RBM-BT24E

42

117.5

127.0

64

21.0 - 56.7

2.90 - 3.72

6.67 - 7.14

4.74 - 4.96

2

22HP+20HP

1830

3220

780

742

64.0 - 65.0

10111

40

1 5/8"

7/8" n/a

23

400 - 3 - 50

TBC

40.5 - 34.1

62.4 - 52.6

Soft Start

£23,167

£158

£23,325

10278

40

1 5/8"

7/8" n/a

23

400 - 3 - 50

TBC

46.4 - 34.2

71.2 - 53.0

Soft Start

£23,950

£158

£24,108

MMY-AP4416HT8P-E

RBM-BT24E

44

123.5

128.0

64

22.0 - 59.4

2.65 - 3.74

6.60 - 7.10

4.77 - 4.98

2

22HP+22HP

1830

3220

780

742

64.0 - 65.0

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

91

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-AP4616HT8P-E

RBM-BT24E x 2

46

130.0

145.0

64

23.0 - 62.1

3.18 - 3.92

7.04 - 7.53

4.93 - 5.14

3

16HP+16HP+14HP

1830

3670

780

900

66.5 - 68.5

10389

40

1 5/8"

7/8" n/a

34.5

400 - 3 - 50

TBC

40.9 - 37.0

64.3 - 58.2

Soft Start

£28,150

£316

£28,466

MMY-AP4816HT8P-E

RBM-BT24E x 2

48

135.0

150.0

64

24.0 - 64.8

3.15 - 3.88

7.09 - 7.58

4.86 - 5.07

3

16HP+16HP+16HP

1830

3670

780

900

67.0 - 69.0

10500

40

1 5/8"

7/8" n/a

34.5

400 - 3 - 50

TBC

42.9 - 38.7

67.2 - 60.6

Soft Start

£28,527

£316

£28,843

11806

40

1 5/8"

7/8" n/a

34.5

400 - 3 - 50

TBC

43.2 - 39.9

67.7 - 62.5

Soft Start

£29,478

£316

£29,794

MMY-AP5016HT8P-E

RBM-BT24E x 2

50

140.4

156.0

64

25.0 - 67.5

3.25 - 3.91

7.00 - 7.46

4.90 - 5.11

3

18HP+16HP+16HP

1830

4060

780

971

66.5 - 68.0

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

SMMSe Hi COP combinations also available.

Contact AMP for more information.

@amp_aircon | amp-air-conditioning 92

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-AP5216HT8P-E

RBM-BT24E x 2

52

146.0

163.0

64

26.0 - 70.2

3.18 - 3.81

6.96 - 7.43

4.81 - 5.02

3

20HP+16HP+16HP

1830

4060

780

971

66.5 - 68.5

11972

40

1 5/8"

7/8" n/a

34.5

400 - 3 - 50

TBC

45.9 - 42.8

71.6 - 66.5

Soft Start

£30,210

£316

£30,526

MMY-AP5416HT8P-E

RBM-BT24E x 2

54

151.5

164.0

64

27.0 - 72.9

2.92 - 3.82

6.91 - 7.41

4.81 - 5.02

3

22HP+16HP+16HP

1830

4060

780

971

66.5 - 68.5

12139

40

1 5/8"

7/8" n/a

34.5

400 - 3 - 50

TBC

51.8 - 42.9

80.4 - 66.9

Soft Start

£30,993

£316

£31,309

13444

40

1 5/8"

7/8" n/a

34.5

400 - 3 - 50

TBC

48.9 - 46.9

76.0 - 72.4

Soft Start

£31,893

£316

£32,209

MMY-AP5616HT8P-E

RBM-BT24E x 2

56

157.0

176.0

64

28.0 - 75.6

3.21 - 3.75

6.84 - 7.30

476 - 4.98

3

20HP+20HP+16HP

1830

4450

780

1042

66.5 - 67.5

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

93

VRF Outdoor

SMMSe Heat Pump Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-AP5816HT8P-E

RBM-BT24E x 2

58

162.5

177.0

64

29.0 - 78.3

2.97 - 3.77

6.76 - 7.26

4.78 - 5.00

3

22HP+20HP+16HP

1830

4450

780

1042

66.5 - 67.5

13611

40

1 5/8"

7/8" na

34.5

400 - 3 - 50

TBC

54.8 - 47.0

84.8 - 72.8

Soft Start

£32,676

£316

£32,992

13778

40

1 5/8"

7/8" na

34.5

400 - 3 - 50

TBC

60.7 - 47.1

93.6 - 73.2

Soft Start

£33,459

£316

£33,775

MMY-AP6016HT8P-E

RBM-BT24E x 2

60

168.0

178.0

64

30.0 - 81.0

2.77 - 3.78

6.80 - 7.28

4.77 - 4.98

3

22HP+22HP+16HP

1830

4450

780

1042

66.5 - 67.5

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-5°C to 46°C | Heating operating range -25°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

SMMSe Hi COP combinations also available.

Contact AMP for more information.

@amp_aircon | amp-air-conditioning 94

VRF Outdoor

SHRMi Heat Recovery Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-MAP0804FT8-E n/a

8

22.4

25.0

13

5.6 - 10.8

4.33 - 4.40

7.13 - 7.45

5.18 - 5.35

1

8HP

1830

990

780

259

55.0 - 57.0

2417

50

7/8"

1/2"

3/4"

11

400 - 3 - 50

16

5.17 - 5.68

8.3 - 9.1

soft start

£6,265

MMY-MAP1004FT8-E n/a

10

28.0

31.5

16

7.0 - 13.5

3.85 - 4.20

6.78 - 7.13

5.16 - 5.35

1

10HP

1830

990

780

259

57.0 - 59.0

2611

40

7/8"

1/2"

3/4"

11

400 - 3 - 50

20

7.28 - 7.50

11.4 - 12.0

soft start

£6,816

MMY-MAP1204FT8-E n/a

12

33.5

37.5

20

8.4 - 16.2

4.00 - 4.14

7.04 - 7.41

5.11 - 5.30

1

12HP

1830

1210

780

334

60.0 - 62.0

3333

40

1 1/8"

1/2"

3/4"

11

400 - 3 - 50

25

8.38 - 9.05

13.4 - 14.5

soft start

£9,384

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm

2 screened cable (2mm 2 after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

95

VRF Outdoor

SHRMi Heat Recovery Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-MAP1404FT8-E n/a

14

40.0

45.0

23

9.8 - 18.9

3.54 - 3.54

6.35 - 6.68

4.85 - 5.08

1

14HP

1830

1210

780

334

62.0 - 64.0

3611

40

1 1/8"

5/8"

7/8"

11

400 - 3 - 50

25

11.30 - 12.70

17.8 - 19.9

Soft Start

£9,853 n/a

£9,853

MMY-AP1614FT8-E

RBM-BT14FE

16

45.0

50.0

27

11.2 - 21.6

4.32 - 4.40

7.09 - 7.42

5.18 - 5.36

2

8HP + 8HP

1830

2000

780

518

58.0 - 60.0

4834

50

1 1/8"

3/4"

7/8"

22

400 - 3 - 50

16 & 16

10.42 - 11.36

16.7 - 18.2

Soft Start

£12,530

£128

£12,658

5028

40

1 1/8"

3/4"

7/8"

22

400 - 3 - 50

20 & 16

12.45 - 13.18

19.7 - 21.1

Soft Start

£13,081

£128

£13,209

MMY-AP1814FT8-E

RBM-BT14FE

18

50.4

56.5

30

12.6 - 24.3

4.05 - 4.29

6.88 - 7.22

5.15 - 5.34

2

10HP + 8HP

1830

2000

780

518

59.5 - 61.5

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

@amp_aircon | amp-air-conditioning 96

VRF Outdoor

SHRMi Heat Recovery Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-AP2014FT8-E

RBM-BT14FE

20

56.0

63.0

33

14.0 - 27.0

3.85 - 4.20

6.78 - 7.13

5.14 - 5.34

2

10HP + 10HP

1830

2000

780

518

60.0 - 62.0

5222

40

1 1/8"

3/4"

7/8"

22

400 - 3 - 50

20 & 20

14.56 - 15.00

22.8 - 24.0

Soft Start

£13,632

£128

£13,760

MMY-AP2214FT8-E

RBM-BT14FE

22

61.5

69.0

37

15.4 - 29.7

3.93 - 4.17

6.92 - 7.28

5.13 - 5.32

2

12HP + 10HP

1830

2220

780

593

62.0 - 64.0

5944

40

1 3/8"

3/4"

1 1/8"

22

400 - 3 - 50

20 & 20

15.66 - 16.55

24.8 - 26.5

Soft Start

£16,200

£128

£16,328

6222

40

1 3/8"

3/4"

1 1/8"

22

400 - 3 - 50

25 & 20

18.58 - 20.20

29.1 - 31.9

Soft Start

£16,669

£128

£16,797

MMY-AP2414FT8-E

RBM-BT14FE

24

68.0

76.5

40

16.8 - 32.4

3.66 - 3.79

6.27 - 6.58

4.80 - 5.00

2

14HP + 10HP

1830

2220

780

593

63.5 - 65.5

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

97

VRF Outdoor

SHRMi Heat Recovery Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-AP2614FT8-E

RBM-BT24FE

26

73.0

81.5

43

18.2 - 35.1

3.75 - 3.82

66.6 - 7.01

4.92 - 5.13

2

14HP + 12HP

1830

2440

780

668

64.5 - 66.5

6944

40

1 3/8"

7/8"

1 1/8"

22

400 - 3 - 50

25 & 20

19.48 - 21.35

30.9 - 33.8

Soft Start

£19,237

£159

£19,396

MMY-AP2814FT8-E

RBM-BT24FE

28

78.5

88.0

47

19.6 - 37.8

3.57 - 3.58

6.40 - 6.74

4.90 - 5.13

2

14HP + 14HP

1830

2440

780

668

65.0 - 67.0

7222

40

1 3/8"

7/8"

1 1/8"

22

400 - 3 - 50

25 & 25

21.98 - 24.60

34.5 - 38.6

Soft Start

£19,706

£159

£19,865

MMY-AP3014FT8-E

RBM-BT24FE x 2

30

85.0

95.0

48

21.0 - 40.5

3.82 - 4.19

6.73 - 7.08

5.13 - 5.32

3

10HP + 10HP + 10HP

1830

3010

780

777

62.0 - 64.0

7833

40

1 3/8"

7/8"

1 1/8"

33

400 - 3 - 50

20, 20 & 20

22.26 - 22.70

34.9 - 36.4

Soft Start

£20,448

£318

£20,766

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-10°C to 43°C | heating operating range -20°C to 15.5°C| 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

@amp_aircon | amp-air-conditioning 98

VRF Outdoor

SHRMi Heat Recovery Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-AP3214FT8-E

RBM-BT24FE x 2

32

90.0

100.0

48

22.4 - 43.2

3.89 - 4.19

6.85 - 7.21

5.16 - 5.35

3

12HP + 10HP + 10HP

1830

3230

780

852

63.0 - 65.0

8555

40

1 3/8"

7/8"

1 1/8"

33

400 - 3 - 50

20, 20 & 20

23.15 - 23.85

36.6 - 38.2

Soft Start

£23,016

£318

£23,334

MMY-AP3414FT8-E

RBM-BT24FE x 2

34

96.0

108.0

48

23.8 - 45.9

3.71 - 3.90

6.57 - 6.92

4.95 - 5.15

3

14HP + 10HP + 10HP

1830

3230

780

852

64.5 - 65.0

8833

40

1 3/8"

7/8"

1 1/8"

33

400 - 3 - 50

25, 20 & 20

25.86 - 27.70

40.6 - 44.0

Soft Start

£23,485

£318

£23,803

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

99

VRF Outdoor

SHRMi Heat Recovery Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

SOUND & AIRFLOW

Airflow Rate

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) in in kg l/s

Pa in

V-Ph-Hz

A kW

A

A

MMY-AP3614FT8-E

RBM-BT24FE x 2

36

101.0

113.0

48

25.2 - 48.3

3.98 - 4.13

6.69 - 7.04

4.98 - 5.18

3

12HP + 12HP + 12HP

1830

3670

780

1002

65.0 - 67.0

10000

40

1 5/8"

7/8"

1 3/8"

33

400 - 3 - 50

20, 20 & 20

25.35 - 27.35

40.6 - 43.8

Soft Start

£28,152

£318

£28,470

MMY-AP3814FT8-E

RBM-BT24FE x 2

38

106.5

119.5

48

26.6 - 51.3

3.82 - 3.91

6.48 - 6.82

4.90 - 5.11

3

14HP + 12HP + 12HP

1830

3670

780

1002

65.5 - 67.5

10278

40

1 5/8"

7/8"

1 3/8"

33

400 - 3 - 50

25, 20 & 20

27.85 - 30.60

44.2 - 48.6

Soft Start

£28,621

£318

£28,939

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-10°C to 43°C | heating operating range -20°C to 15.5°C| 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

@amp_aircon | amp-air-conditioning 100

VRF Outdoor

SHRMi Heat Recovery Outdoor Units

Outdoor Unit

Connection Kit

Horse Power

Nominal Cooling

Nominal Heating

Maximum Number of Indoor Units

Min - Max Connected Capacity Code**

EER - COP

SEER - ESEER value (Office Profile)

SCOP - ESCOP (Value)

Number of Modules

Size of Modules

Height

Width*

Depth

Weight

Sound Pressure Level (Cool - Heat)

Airflow Rate

SOUND & AIRFLOW

Max External Static Pressure**

Gas Pipe Size

Liquid Pipe Size

Discharge Pipe Size

R410A Refrigerant Base Charge

Power Supply

Suggested Fuse Size

Power Input (Cool - Heat)

Running Current (Cool - Heat)

Starting Current

Outdoor Unit

Connection Kit

Retail Price

kW kW

HP mm mm mm kg dB(A) l/s

Pa in in in kg

V-Ph-Hz

A kW

A

A

MMY-AP4014FT8-E

RBM-BT24FE x 2

40

112.0

127.0

48

28.0 - 54.0

3.68 - 3.71

6.56 - 6.90

4.88 - 5.09

3

14HP + 14HP + 12HP

1830

3670

780

1002

66.5 - 68.5

10555

40

1 5/8"

7/8"

1 3/8"

33

400 - 3 - 50

25, 25 & 20

30.40 - 34.25

48.2 - 54.1

Soft Start

£29,090

£318

£29,408

MMY-AP4214FT8-E

RBM-BT24FE x 2

42

118.0

132.0

48

29.4 - 56.7

3.56 - 3.58

6.38 - 6.72

4.89 - 5.12

3

14HP + 14HP + 14HP

1830

3670

780

1002

67.0 - 69.0

10833

40

1 5/8"

7/8"

1 3/8"

33

400 - 3 - 50

25, 25 & 25

33.10 - 36.90

51.9 - 57.9

Soft Start

£29,559

£318

£29,877

*Width assumes 20mm gap between modules | **Condition apply, see technical manual for details | For pipe work limitations see installation manual | Cooling operating range

-10°C to 43°C | Heating operating range -20°C to 15.5°C | 2 core non polar 1.5mm

2

screened cable (2mm

2

after 1000m total length).

ampair.co.uk | 01707 378 670 | [email protected]

101

VRF Indoor

Flow Selector Units & Branch Pipes

Flow Selector Units RBM-Y1123FE RBM-Y1803FE RBM-Y2803FE

Connectible Indoor Unit Capacity

Maximum number of indoor units

Height

Width

Depth

Weight mm mm mm

Kg

Below 4.0HP

5

190

250

160

5

4.0 to below 6.4HP

8

190

250

160

5

6.4 to 10.0HP

8

200

400

200

8

Indoor Side Connection Size

Outdoor Side Connection Size

Connection Type

Power Supply in in

V-Ph-Hz

3/8” & 5/8"

3/8”, 1/2" & 5/8"

Brazed

230 - 1 - 50

3/8” & 5/8”

3/8”, 1/2” & 5/8”

Brazed

230 - 1 - 50

1/2” & 7/8”

1/2”, 3/4” & 5/8”

Brazed

230 - 1 - 50

Retail Price

£531 £589 £923

Multiple indoor units connected to the same flow selector unit will operate in the same mode using a single source of control | Flow selectors come complete with a 5m cable for connection to associated indoor unit, this can be extended to 15m by using part RBC-FSEX15 £104 retail

2 Pipe Branch Joints & Header Pipes

Model Type

RBM-BY55E

RBM-BY105E

RBM-BY205E

Branch Pipe Kit

Branch Pipe Kit

Branch Pipe Kit

RBM-BY305E

RBM-HY1043E

RBM-HY2043E

RBM-HY1083E

RBM-HY2083E

Branch Pipe Kit

4 Way Header

4 Way Header

8 Way Header

8 Way Header

Description

Downstream capacity of less than 6.4HP

Downstream capacity of 6.4 to 14.2HP

Downstream capacity of 14.2 - 25.2HP

Downstream capacity of 25.2HP or more

Downstream capacity of less than 14.2HP

Downstream capacity of 14.2 to 25.2HP

Downstream capacity of less than 14.2HP

Downstream capacity of 14.2 - 25.2HP

Retail Price

£57

£70

£116

£154

£128

£102

£148

£143

3 Pipe Branch Joints & Header Pipes

Model

RBM-BY55FE

RBM-BY105FE

RBM-BY205FE

RBM-BY305FE

RBM-HY1043FE

RBM-HY2043FE

RBM-HY1083FE

RBM-HY2083FE

Type

Branch Pipe Kit

Branch Pipe Kit

Branch Pipe Kit

Branch Pipe Kit

4 Way Header

4 Way Header

8 Way Header

8 Way Header

Description

Downstream capacity of less than 6.4HP

Downstream capacity of 6.4 to 14.2HP

Downstream capacity of 14.2 - 25.2HP

Downstream capacity of 25.2HP or more

Downstream capacity of less than 14.2HP

Downstream capacity of 14.2 to 25.2HP

Downstream capacity of less than 14.2HP

Downstream capacity of 14.2 - 25.2HP

Outdoor Connection Kits

Model

RBM-BT14E

Type Description

Outdoor Connection Kit Y Connector less than 26HP SMMSe

RBM-BT24E

RBM-BT14FE

RBM-BT24FE

Outdoor Connection Kit

Outdoor Connection Kit

Outdoor Connection Kit

Y Connector greater than 26HP SMMSe

Y Connector less than 26HP SHRMi

Y Connector greater than 26HP SHRMi

Retail Price

£65

£89

£133

£219

£130

£130

£214

£210

Retail Price

£127

£158

£128

£159

@amp_aircon | amp-air-conditioning 102

VRF Indoor

Range Overview

126

129

130

132

134

106

108

110

114

118

122

137

140

142

144

148

150

Nominal Cooling kW

Nominal Heating kW

Indoor Unit Type

Capacity Code (HP)

1 Way Cassette

600mm

2

Compact Cassette

4 Way Cassette

2 Way Cassette

Standard Ducted

Slim Ducted

ü

ü

High Static Ducted

High Static Ducted (high Flow)

3 Series Wall Mounted

4 Series Wall Mounted

Ceiling Suspended

ü

1.7 2.2 2.8 3.6 4.5 5.6 7.1 8.0 9.0 11.2 14.0 16.0 22.4 28.0

1.9 2.5 3.2 4.0 5.0 6.3 8.0 9.0 10.0 12.5 16.0 18.0 25.0 31.5

005* 007* 009* 012* 015* 018* 024* 027* 030* 036* 048* 056* 072* 096*

0.6 0.8

1 1.25 1.7

2 2.5

3 3.2

4 5 6 8 10

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü ü

Floor Mounted Cabinet

Floor Standing Chassis

Floor Mounted Console

Floor Mounted Bi Flow

Air to air with DX coil

Fresh air intake unit

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü

ü ü ü

ü

ü

ü ü

005* models are only compatible with SMMSe outdoor units

VRF Indoor

UK Cooling Capacities

Indoor

Unit

Type

030*

036*

048*

056*

072*

096*

005*

007*

009*

012*

015*

018*

024*

027*

The unit capacities shown is the booklet are all nominal figures. The tables below show the cooling capacities at various design conditions.

These figures are the approximate capacities for the SMMSe systems with 4 way cassette indoor units. Figures for the SHRMi / other indoors will be similar. 005* models are only compatible with SMMSe outdoor units

Capacity

Code

0.6

0.8

1

1.25

1.7

2

2.5

3

3.2

4

5

6

8

10

Linear separation = 20m

High Fan Speed

Sensible Cooling (kW)

5.79

7.19

9.15

10.27

13.92

17.09

1.21

1.59

1.96

2.53

2.99

3.74

4.30

5.14

Total Cooling (kW)

8.08

10.06

12.57

14.37

20.11

25.14

1.53

1.98

2.51

3.29

4.04

5.03

6.37

7.18

Low Fan Speed

Sensible Cooling (kW)

4.29

5.32

6.77

7.60

10.30

12.65

0.90

1.17

1.45

1.87

2.21

2.76

3.18

3.80

Total Cooling (kW)

6.46

8.04

10.06

11.49

16.09

20.11

1.22

1.58

2.01

2.63

3.23

4.02

5.10

5.75

Indoor

Unit

Type

030*

036*

048*

056*

072*

096*

005*

007*

009*

012*

015*

018*

024*

027*

Capacity

Code

3.2

4

5

6

8

10

0.6

0.8

1

1.25

1.7

2

2.5

3

Linear separation = 50m

High Fan Speed

Sensible Cooling (kW)

5.69

7.06

8.99

10.09

13.67

16.79

1.19

1.56

1.93

2.48

2.94

3.67

4.22

5.05

Total Cooling (kW)

7.44

9.26

11.57

13.23

18.52

23.15

1.41

1.82

2.31

3.03

3.72

4.63

5.87

6.61

Low Fan Speed

Sensible Cooling (kW)

4.21

5.23

6.65

7.47

10.12

12.42

0.88

1.15

1.43

1.84

2.17

2.72

3.12

3.73

Total Cooling (kW)

5.95

7.41

9.26

10.58

14.81

18.52

1.12

1.46

1.85

2.42

2.98

3.70

4.70

5.29

Indoor

Unit

Type

030*

036*

048*

056*

072*

096*

005*

007*

009*

012*

015*

018*

024*

027*

Capacity

Code

3.2

4

5

6

8

10

0.6

0.8

1

1.25

1.7

2

2.5

3

Linear separation = 80m

High Fan Speed

Sensible Cooling (kW)

5.59

6.94

8.83

9.91

13.42

16.49

1.17

1.53

1.89

2.44

2.88

3.60

4.14

4.96

Total Cooling (kW)

6.94

8.64

10.80

12.34

17.28

21.60

1.31

1.70

2.16

2.82

3.47

4.32

5.48

6.17

Low Fan Speed

Sensible Cooling (kW)

4.13

5.13

6.53

7.33

9.93

12.20

0.87

1.13

1.40

1.80

2.13

2.67

3.07

3.67

Total Cooling (kW)

5.55

6.91

8.64

9.87

13.82

17.28

1.05

1.36

1.73

2.26

2.78

3.46

4.38

4.94

@amp_aircon | amp-air-conditioning 104

VRF Indoor

UK Heating Capacities

Indoor Unit

Type

030*

036*

048*

056*

072*

096*

005*

007*

009*

012*

015*

018*

024*

027*

Capacity Code

3.2

4

5

6

8

10

0.6

0.8

1

1.25

1.7

2

2.5

3

High Fan Speed

Linear separation = 80m

Low Fan Speed

7.53

9.41

12.04

13.55

18.82

23.71

1.43

1.88

2.41

3.02

3.76

4.74

6.04

6.77

6.02

7.53

9.64

10.84

15.05

18.97

1.14

1.51

1.93

2.42

3.01

3.79

4.83

5.42

ampair.co.uk | 01707 378 670 | [email protected]

105

VRF Indoor

1 Way Cassettes

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMU-AP0074YH1-E

RBC-UY135PG

0.8

2.2

2.5

235 (18)

850 (1050)

400 (470)

22 (3.5)

34 - 39 - 42

117 - 133 - 150 n/a

3/8”

1/4”

25 nom.

Yes (350mm)*

230 - 1 - 50

3

0.053

0.24

0.60

£1,100

£226

£1,326

MMU-AP0094YH1-E

RBC-UY135PG

1

2.8

3.2

235 (18)

850 (1050)

400 (470)

22 (3.5)

34 - 39 - 42

117 - 133 - 150 n/a

3/8”

1/4”

25 nom.

Yes (350mm)*

230 - 1 - 50

3

0.053

0.24

0.60

£1,135

£226

£1,361

MMU-AP0124YH1-E

RBC-UY135PG

1.25

3.6

4.0

235 (18)

850 (1050)

400 (470)

22 (3.5)

34 - 39 - 42

117 - 133 - 150 n/a

3/8”

1/4”

25 nom.

Yes (350mm)*

230 - 1 - 50

3

0.053

0.24

0.60

£1,169

£226

£1,395

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 350 from the underside of the ceiling tile

@amp_aircon | amp-air-conditioning 106

VRF Indoor

1 Way Cassettes

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0154SH1-E

RBC-US21PG-E

1.7

4.5

5.0

200 (20)

1000 (1230)

710 (800)

21 (5.5)

32 - 35 - 37

175 - 192 - 208 n/a

MMU-AP0184SH1-E

RBC-US21PG-E

2

5.6

6.3

200 (20)

1000 (1230)

710 (800)

21 (5.5)

34 - 36 - 38

183 - 200 - 217 n/a

MMU-AP0244SH1-E

RBC-US21PG-E

2.5

7.1

8.0

200 (20)

1000 (1230)

710 (800)

22 (5.5)

37 - 41 - 45

225 - 267 - 317 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

1/2”

1/4”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.042

0.34

0.51

£1,037

1/2”

1/4”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.046

0.37

0.54

£1,189

5/8”

3/8”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.075

0.62

0.80

£1,267

Grille

Retail Price

£310

£1,347

£310

£1,499

£310

£1,577

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake

ampair.co.uk | 01707 378 670 | [email protected]

107

VRF Indoor

4 Way Compact Cassettes

SOUND & AIRFLOW

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0056MH1-E

RBC-UM11PG(W)E

0.6

1.7

1.9

268 (27)

575 (700)

575 (700)

17 (3.0)

28 - 32 - 35

105 - 128 - 135 n/a

MMU-AP0074MH1-E

RBC-UM11PG(W)E

0.8

2.2

2.5

268 (27)

575 (700)

575 (700)

17 (3.0)

28 - 32 - 36

105 - 128 - 153 n/a

MMU-AP0094MH1-E

RBC-UM11PG(W)E

1

2.8

3.2

268 (27)

575 (700)

575 (700)

17 (3.0)

28 - 33 - 37

105 - 130 - 158 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

3/8”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.034

0.28

0.49

£704

3/8”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.034

0.28

0.49

£705

3/8”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.036

0.30

0.52

£757

Grille

Retail Price

£200

£904

£200

£905

£200

£957

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |

Knock out for fresh air intake 64 x 64 | 0056 model is only compatible with SMMSe outdoor units

@amp_aircon | amp-air-conditioning 108

VRF Indoor

4 Way Compact Cassettes

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0124MH1-E

RBC-UM11PG(W)E

1.25

3.6

4.0

268 (27)

575 (700)

575 (700)

17 (3.0)

29 - 33 - 37

112 - 140 - 165 n/a

MMU-AP0154MH1-E

RBC-UM11PG(W)E

1.7

4.5

5.0

268 (27)

575 (700)

575 (700)

17 (3.0)

30 - 35 - 40

130 - 153 - 183 n/a

MMU-AP0184MH1-E

RBC-UM11PG(W)E

2

5.6

6.3

268 (27)

575 (700)

575 (700)

17 (3.0)

34 - 39 - 44

145 - 178 - 212 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

3/8”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.038

031

0.54

£789

1/2”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.041

0.34

0.59

£831

1/2”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.052

0.42

0.73

£885

Grille

Retail Price

£200

£989

£200

£1,031

£200

£1,085

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |

Knock out for fresh air intake 64 x 64 | 0056 model is only compatible with SMMSe outdoor units

RBC-AMS54E-ES £105 Retail

ampair.co.uk | 01707 378 670 | [email protected]

109

VRF Indoor

4 Way Cassettes

SOUND & AIRFLOW

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0094HP1-E

RBC-U31PGP(W)-E

1

2.8

3.2

256 (30)

840 (950)

840 (950)

20 (4.0)

27 - 29 - 30

189 - 203 - 222 n/a

MMU-AP0124HP1-E

RBC-U31PGP(W)-E

1.25

3.6

4.0

256 (30)

840 (950)

840 (950)

20 (4.0)

27 - 29 - 30

189 - 203 - 222 n/a

MMU-AP0154HP1-E

RBC-U31PGP(W)-E

1.7

4.5

5.0

256 (30)

840 (950)

840 (950)

20 (4.0)

27 - 29 - 31

219 - 231 - 258 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

3/8”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.021

0.23

0.30

£806

3/8”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.021

0.23

0.30

£830

1/2”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.023

0.27

0.33

£876

Grille

Retail Price

£154

£960

£154

£984

£154

£1,030

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |

Knock out for fresh air intake 64 x 57

@amp_aircon | amp-air-conditioning 110

VRF Indoor

4 Way Cassettes

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0184HP1-E

RBC-U31PGP(W)-E

2

5.6

6.3

256 (30)

840 (950)

840 (950)

20 (4.0)

27 - 29 - 32

222 - 256 - 292 n/a

MMU-AP0244HP1-E

RBC-U31PGP(W)-E

2.5

7.1

8.0

256 (30)

840 (950)

840 (950)

20 (4.0)

28 - 31 - 35

222 - 256 - 358 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

1/2”

1/4”

25od

Yes (850mm)*

230 - 1 - 50

3

0.026

0.29

0.36

£899

5/8”

3/8”

25od

Yes (850mm)*

230 - 1 - 50

3

0.036

0.38

0.42

£939

Grille

Retail Price

£154

£1,053

£154

£1,093

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |

Knock out for fresh air intake 64 x 57

RBC-AS41E £70 Retail

ampair.co.uk | 01707 378 670 | [email protected]

111

VRF Indoor

4 Way Cassettes

SOUND & AIRFLOW

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0274HP1-E

RBC-U31PGP(W)-E

3

8.0

9.0

256 (30)

840 (950)

840 (950)

20 (4.0)

28 - 31 - 35

222 - 256 - 358 n/a

MMU-AP0304HP1-E

RBC-U31PGP(W)-E

3.2

9.0

10.0

256 (30)

840 (950)

840 (950)

20 (4.0)

30 - 33 - 38

236 - 306 - 367 n/a

MMU-AP0364HP1-E

RBC-U31PGP(W)-E

4

11.2

12.5

319 (30)

840 (950)

840 (950)

25 (4.0)

32 - 38 - 43

297 - 397 - 547 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

5/8”

3/8”

25od

Yes (850mm)*

230 - 1 - 50

3

0.036

0.38

0.42

£1,117

5/8”

3/8”

25od

Yes (850mm)*

230 - 1 - 50

3

0.043

0.43

0.59

£1,222

5/8”

3/8”

25od

Yes (850mm)*

230 - 1 - 50

3

0.088

0.73

0.87

£1,292

Grille

Retail Price

£154

£1,271

£154

£1,376

£154

£1,446

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |

Knock out for fresh air intake 64 x 57

@amp_aircon | amp-air-conditioning 112

VRF Indoor

4 Way Cassettes

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0484HP1-E

RBC-U31PGP(W)-E

5

14.0

16.0

319 (30)

840 (950)

840 (950)

25 (4.0)

33 - 38 - 46

314 - 397 - 592 n/a

MMU-AP0564HP1-E

RBC-U31PGP(W)-E

6

16.0

18.0

319 (30)

840 (950)

840 (950)

25 (4.0)

33 - 40 - 46

342 - 422 - 592 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

5/8”

3/8”

25od

Yes (850mm)*

230 - 1 - 50

3

0.112

0.88

1.23

£1,350

5/8”

3/8”

25od

Yes (850mm)*

230 - 1 - 50

3

0.112

0.88

1.26

£1,523

Grille

Retail Price

£154

£1,504

£154

£1,677

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct 105 x 105 |

Knock out for fresh air intake 64 x 57

RBC-AMT32E £50 Retail

ampair.co.uk | 01707 378 670 | [email protected]

113

VRF Indoor

2 Way Cassettes

SOUND & AIRFLOW

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0072WH1-E

RBC-UW283PG(W)-E

0.8

2.2

2.5

295 (20)

815 (1050)

570 (680)

19 (10)

30 - 32 - 34

125 - 138 - 155 n/a

MMU-AP0092WH1-E

RBC-UW283PG(W)-E

1

2.8

3.2

295 (20)

815 (1050)

570 (680)

19 (10)

30 - 32 - 34

125 - 138 - 155 n/a

MMU-AP0122WH1-E

RBC-UW283PG(W)-E

1.25

3.6

4.0

295 (20)

815 (1050)

570 (680)

19 (10)

30 - 32 - 34

125 - 138 - 155 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

3/8”

1/4”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.029

0.23

0.35

£885

3/8”

1/4”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.029

0.23

0.35

£915

3/8”

1/4”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.029

0.23

0.35

£942

Grille

Retail Price

£221

£1,106

£221

£1,136

£221

£1,163

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake

MMU-AP0242WH1-E

@amp_aircon | amp-air-conditioning 114

VRF Indoor

2 Way Cassettes

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0152WH1-E

RBC-UW283PG(W)-E

1.7

4.5

5.0

295 (20)

815 (1050)

570 (680)

19 (10)

30 - 33 - 35

125 - 148 - 167 n/a

MMU-AP0182WH1-E

RBC-UW803PG(W)-E

2

5.6

6.3

345 (20)

1180 (1415)

570 (680)

26 (14)

30 - 33 - 35

172 - 208 - 250 n/a

MMU-AP0242WH1-E

RBC-UW803PG(W)-E

2.5

7.1

8.0

345 (20)

1180 (1415)

570 (680)

26 (14)

33 - 35 - 38

205 - 233 - 292 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

1/2”

1/4”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.030

0.24

0.36

£980

1/2”

1/4”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.044

0.32

0.48

£1,072

5/8”

3/8”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.054

0.39

0.59

£1,138

Grille

Retail Price

£221

£1,201

£294

£1,366

£294

£1,432

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake

RBC-AMS54E-ES £105 Retail

ampair.co.uk | 01707 378 670 | [email protected]

115

VRF Indoor

2 Way Cassettes

SOUND & AIRFLOW

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0272WH1-E

RBC-UW803PG(W)-E

3

8.0

9.0

345 (20)

1180 (1415)

570 (680)

26 (14)

33 - 35 - 38

205 - 233 - 292 n/a

MMU-AP0302WH1-E

RBC-UW803PG(W)-E

3.2

9.0

10.0

345 (20)

1180 (1415)

570 (680)

26 (14)

34 - 37 - 40

217 - 250 - 350 n/a

MMU-AP0362WH1-E

RBC-UW1403PG(W)-E

4

11.2

12.5

345 (20)

1600 (1835)

570 (680)

36 (14)

36 - 39 - 42

328 - 398 - 483 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

5/8”

3/8”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.054

0.39

0.59

£1,310

5/8”

3/8”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.064

0.46

0.69

£1,323

5/8”

3/8”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.073

0.48

0.72

£1,589

Grille

Retail Price

£294

£1,604

£294

£1,617

£336

£1,925

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake

MMU-AP0242WH1-E

@amp_aircon | amp-air-conditioning 116

VRF Indoor

2 Way Cassettes

Indoor Unit

Grille

Capacity Code

Nominal Cooling

Nominal Heating

Height - Unit (Grille)

Width - Unit (Grille)

Depth - Unit (Grille)

Weight - Unit (Grille)

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure kW kW mm mm mm kg dB(A) l/s

Pa

MMU-AP0482WH1-E

RBC-UW1403PG(W)-E

5

14.0

16.0

345 (20)

1600 (1835)

570 (680)

36 (14)

37 - 40 - 43

342 - 412 - 500 n/a

MMU-AP0562WH1-E

RBC-UW1403PG(W)-E

6

16.0

18.0

345 (20)

1600 (1835)

570 (680)

36 (14)

39 - 42 - 46

367 - 438 - 567 n/a

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

5/8”

3/8”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.088

0.57

0.86

£1,743

5/8”

3/8”

25 nom.

Yes (850mm)*

230 - 1 - 50

3

0.117

0.75

1.13

£1,913

Grille

Retail Price

£336

£2,079

£336

£2,249

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the underside of the ceiling tile | Knock out for branch duct | Knock out for fresh air intake

RBC-AMS41E £66 Retail

ampair.co.uk | 01707 378 670 | [email protected]

117

VRF Indoor

Standard Ducted

SOUND & AIRFLOW

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0076BHP1-E

AMP-RAVBTE-2DUCT

0.8

2.2

2.5

275

700

750

23

23 - 26 - 29

100 - 125 - 150

30 (30 - 120)

MMD-AP0096BHP1-E

AMP-RAVBTE-2DUCT

1

2.8

3.2

275

700

750

23

23 - 26 - 30

108 - 133 - 158

30 (30 - 120)

MMD-AP0126BHP1-E

AMP-RAVBTE-2DUCT

1.25

3.6

4.0

275

700

750

23

23 - 26 - 30

108 - 133 - 158

30 (30 - 120)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current in in mm

V-Ph-Hz

A kW

A

3/8”

1/4”

25

Yes (850mm)*

230 - 1 - 50

3

0.038

0.26

3/8”

1/4”

25

Yes (850mm)*

230 - 1 - 50

3

0.043

0.29

3/8”

1/4”

25

Yes (850mm)*

230 - 1 - 50

3

0.043

0.29

Starting Current

Indoor Unit

A

0.45

£776

0.5

£754

0.5

£796

Spigot Kit £40 £40 £40

Retail Price £816 £794 £836

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard

MMD-AP0306BHP1-E

@amp_aircon | amp-air-conditioning 118

VRF Indoor

Standard Ducted

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0156BHP1-E

AMP-RAVBTE-2DUCT

1.7

4.5

5.0

275

700

750

23

25 - 29 - 33

150 - 183 - 217

30 (30 - 120)

MMD-AP0186BHP1-E

AMP-RAVBTE-2DUCT

2

5.6

6.3

275

700

750

23

25 - 29 - 33

150 - 183 - 217

30 (30 - 120)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current in in mm

V-Ph-Hz

A kW

A

1/2”

1/4”

25

Yes (850mm)*

230 - 1 - 50

3

0.062

0.42

1/2”

1/4”

25

Yes (850mm)*

230 - 1 - 50

3

0.062

0.42

Starting Current

Indoor Unit

A

0.73

£819

0.73

£875

Spigot Kit £40 £40

Retail Price £859 £915

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard

RBC-AS41E £70 Retail

ampair.co.uk | 01707 378 670 | [email protected]

119

VRF Indoor

Standard Ducted

SOUND & AIRFLOW

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0246BHP1-E

AMP-RAVBTE-3DUCT

2.5

7.1

8.0

275

1000

750

30

27 - 31 - 36

242 - 267 - 333

40 (30 - 120)

MMD-AP0276BHP1-E

AMP-RAVBTE-3DUCT

3

8.0

9.0

275

1000

750

30

27 - 31 - 36

242 - 267 - 333

40 (30 - 120)

MMD-AP0306BHP1-E

AMP-RAVBTE-3DUCT

3.2

9.0

10.0

275

1000

750

30

27 - 31 - 36

258 - 300 - 350

40 (30 - 120)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current in in mm

V-Ph-Hz

A kW

A

5/8”

3/8”

25

Yes (850mm)*

230 - 1 - 50

3

0.077

0.52

5/8”

3/8”

25

Yes (850mm)*

230 - 1 - 50

3

0.077

0.52

5/8”

3/8”

25

Yes (850mm)*

230 - 1 - 50

3

0.094

0.61

Starting Current

Indoor Unit

A

0.90

£914

0.90

£1,013

1.06

£1,082

Spigot Kit £54 £54 £54

Retail Price £968 £1,067 £1,136

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard

MMD-AP0306BHP1-E

@amp_aircon | amp-air-conditioning 120

VRF Indoor

Standard Ducted

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0366BHP1-E

AMP-RAVBTE-4DUCT

4

11.2

12.5

275

1400

750

40

33 - 36 - 40

383 - 450 - 533

50 (30 - 120)

MMD-AP0486BHP1-E

AMP-RAVBTE-4DUCT

5

14.0

16.0

275

1400

750

40

33 - 36 - 40

417 - 483 - 583

50 (30 - 120)

MMD-AP0566BHP1-E

AMP-RAVBTE-4DUCT

6

16.0

18.0

275

1400

750

40

33 - 36 - 40

417 - 483 - 583

50 (30 - 120)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current in in mm

V-Ph-Hz

A kW

A

5/8”

3/8”

25

Yes (850mm)*

230 - 1 - 50

3

0.172

1.07

5/8”

3/8”

25

Yes (850mm)*

230 - 1 - 50

3

0.198

1.23

5/8”

3/8”

25

Yes (850mm)*

230 - 1 - 50

3

0.198

1.23

Starting Current

Indoor Unit

A

1.85

£1,240

2.13

£1,327

2.13

£1,409

Spigot Kit £67 £67 £67

Retail Price £1,307 £1,394 £1,476

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | as standard units come with rectangular air outlets, 640 x 180 (0076 - 0186), 940 x 180 (0246 - 0306), 1340 x 180 (0366 - 0566). The optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | Return air filter as standard

RBC-AMS54E-ES £105 Retail

ampair.co.uk | 01707 378 670 | [email protected]

121

VRF Indoor

Slim Ducted

SOUND & AIRFLOW

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)**

Airflow Rate (lo-me-hi)

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0056SPH1-E n/a

0.6

1.7

1.9

210

845

645

22

30 - 33 - 36 / 24 - 26 - 27

112 - 130 - 137

6 (6-46)

MMD-AP0074SPH1-E n/a

0.8

2.2

2.5

210

845

645

22

30 - 33 - 36 / 24 - 26 - 28

111 - 131 - 150

6 (6-46)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

3/8”

1/4”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.039

0.29

0.51

£693

3/8”

1/4”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.039

0.29

0.51

£693

Spigot Kit

Retail Price

n/a

£693

n/a

£693

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units

MMD-AP0074SPH1-E

@amp_aircon | amp-air-conditioning 122

VRF Indoor

Slim Ducted

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0094SPH1-E n/a

1

2.8

3.2

210

845

645

22

30 - 33 - 36 / 24 - 26 - 28

111 - 131 - 150

6 (6-46)

MMD-AP0124SPH1-E n/a

1.25

3.6

4.0

210

845

645

22

32 - 35 - 38 / 25 - 27 - 29

125 - 144 - 167

5 (5-45)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

3/8”

1/4”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.039

0.29

0.51

£702

3/8”

1/4”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.043

0.31

0.54

£722

Spigot Kit

Retail Price

n/a

£702

n/a

£722

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units

RBC-AS41E £70 Retail

ampair.co.uk | 01707 378 670 | [email protected]

123

VRF Indoor

Slim Ducted

SOUND & AIRFLOW

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)**

Airflow Rate (lo-me-hi)

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0154SPH1-E n/a

1.7

4.5

5.0

210

845

645

23

33 - 36 - 39 / 28 - 30 - 32

144 - 167 - 192

5 (5 - 45)

MMD-AP0184SPH1-E n/a

2

5.6

6.3

210

845

645

23

36 - 38 - 40 / 29 - 31 - 33

161 - 189 - 217

4 (4 - 44)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

1/2”

1/4”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.045

0.32

0.56

£752

1/2”

1/4”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.054

0.39

0.68

£790

Spigot Kit

Retail Price

n/a

£752

n/a

£790

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units

MMD-AP0074SPH1-E

@amp_aircon | amp-air-conditioning 124

VRF Indoor

Slim Ducted

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0244SPH1-E n/a

2.5

7.1

8.0

210

1140

645

29

44 - 47 - 49 / 33 - 36 - 38

250 - 278 - 300

42 (2 - 42)

MMD-AP0274SPH1-E n/a

3

8.0

9.0

210

1140

645

29

44 - 47 - 49 / 33 - 36 - 38

250 - 278 - 300

42 (2 - 42)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

5/8”

3/8”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.105

0.75

1.13

£853

5/8”

3/8”

32 od 25 id

Yes (850mm)*

230 - 1 - 50

3

0.105

0.75

1.13

£921

Spigot Kit

Retail Price

n/a

£853

n/a

£921

Communication cable - 2 core non polar 1.5mm

2

screened cable | * Max height of lift pump is 850 from the bottom of the unit | ** Bottom return / rear return | Unit comes as bottom return as standard, can be changed to rear return | Knock out for fresh air intake | Return air filter as standard | 0056 model only compatible with SMMSe outdoor units

RBC-AMS41E £66 Retail

ampair.co.uk | 01707 378 670 | [email protected]

125

VRF Indoor

High Static Ducted

SOUND & AIRFLOW

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0186HP1-E n/a

2

5.6

6.3

298

1000

750

34

30 - 32 - 37

152 - 183 - 222

100 (50 - 200)

MMD-AP0246HP1-E n/a

2.5

7.1

8.0

298

1000

750

34

31 - 34 - 38

222 - 269 - 333

100 (50 - 200)

MMD-AP0276HP1-E n/a

3

8.0

9.0

298

1000

750

34

31 - 34 - 38

222 - 269 - 333

100 (50 - 200)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

1/2”

1/4”

25 nom.

Yes

230 - 1 - 50

3

0.085

0.52

0.78

£1,028

5/8”

3/8”

25 nom.

Yes

230 - 1 - 50

3

0.115

0.70

1.05

£1,133

5/8”

3/8”

25 nom.

Yes

230 - 1 - 50

3

0.115

1.17

1.75

£1,182

Spigot Kit

Retail Price

n/a

£1,028

n/a

£1,133

n/a

£1,182

Communication cable - 2 core non polar 1.5mm

2

screened cable | Unit does not come with a filter | Air outlet dimensions 180 x 940 (0186 - 0276), 180 x 1340 (0366 - 0566),

TBC (0762 - 0966)

MMD-AP0486HP1-E

@amp_aircon | amp-air-conditioning 126

VRF Indoor

High Static Ducted

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure (standard (min-max)) kW kW mm mm mm kg dB(A) l/s

Pa

MMD-AP0366HP1-E n/a

4

11.2

12.5

298

1400

750

43

34 - 37 - 41

372 - 433 - 533

100 (50 - 200)

MMD-AP0486HP1-E n/a

5

14.0

16.0

298

1400

750

43

35 - 40 - 42

394 - 483 - 583

100 (50 - 200)

MMD-AP0566HP1-E n/a

6

16.0

18.0

298

1400

750

43

37 - 42 - 45

461 - 567 - 667

100 (50 - 200)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit in in mm

V-Ph-Hz

A kW

A

A

5/8”

3/8”

25 nom.

Yes

230 - 1 - 50

3

0.198

1.17

1.75

£1,239

5/8”

3/8”

25 nom.

Yes

230 - 1 - 50

3

0.230

1.34

2.01

£1,371

5/8”

3/8”

25 nom.

Yes

230 - 1 - 50

3

0.290

1.68

2.51

£1,467

Spigot Kit

Retail Price

n/a

£1,239

n/a

£1,371

n/a

£1,467

Communication cable - 2 core non polar 1.5mm

2

screened cable | Unit does not come with a filter | Air outlet dimensions 180 x 940 (0186 - 0276), 180 x 1340 (0366 - 0566),

TBC (0762 - 0966)

RBC-AMS54E-ES £105 Retail

ampair.co.uk | 01707 378 670 | [email protected]

127

VRF Indoor

High Static Ducted

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate

SOUND & AIRFLOW

Static Pressure (standard (min-max))

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump kW kW mm mm mm kg dB(A) l/s

Pa in in mm

MMD-AP0726HP1-E n/a

8

22.4

25.0

448

1400

900

97

36 - 40 - 44

1056

150 (50 - 250)

7/8”

1/2”

25 nom.

No

MMD-AP0966HP1-E n/a

10

28.0

31.5

448

1400

900

97

38 - 42 - 46

1333

150 (50 - 250)

7/8”

1/2”

25 nom.

No

Power Supply

Suggested Fuse Size

Power Input

V-Ph-Hz

A kW

230 - 1 - 50

10

0.540

230 - 1 - 50

10

0.790

Running Current

Starting Current

Indoor Unit

Spigot Kit

A

A

2.80

7.80

£2,476 n/a

3.75

7.80

£2,616 n/a

Retail Price £2,476 £2,616

Communication cable - 2 core non polar 1.5mm

2

screened cable | Unit does not come with a filter | Air outlet dimensions 180 x 940 (0186 - 0276), 180 x 1340 (0366 - 0566),

TBC (0762 - 0966)

@amp_aircon | amp-air-conditioning 128

VRF Indoor

High Static Ducted - High Flow

Indoor Unit

Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure (standard (min-max))

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMD-AP0364H-EU n/a

4

11.2

12.5

TBC

TBC

TBC

TBC

TBC

TBC

TBC

5/8”

3/8”

TBC

TBC

230 - 1 - 50

3

TBC

TBC

TBC

£3,210 n/a

£3,210

MMD-AP0484H-EU n/a

5

14.0

16.0

TBC

TBC

TBC

TBC

TBC

TBC

TBC

5/8”

3/8”

TBC

TBC

230 - 1 - 50

3

TBC

TBC

TBC

£3,552 n/a

£3,552

Communication cable - 2 core non polar 1.5mm

2

screened cable

MMD-AP0564H-EU n/a

6

16.0

18.0

TBC

TBC

TBC

TBC

TBC

TBC

TBC

5/8”

3/8”

TBC

TBC

230 - 1 - 50

3

TBC

TBC

TBC

£3,801 n/a

£3,801

RBC-AMT32E £50 Retail

ampair.co.uk | 01707 378 670 | [email protected]

129

VRF Indoor

Wall Mounted 3 Series

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

V-Ph-Hz

A kW

A

A kW kW mm mm mm kg dB(A) l/s

Pa in in mm

3/8”

1/4”

16 nom.

No

230 - 1 - 50

3

0.018

0.17

0.22

£735 n/a

£735

MMK-AP0073H1 n/a

0.8

2.2

2.5

320

1050

228

15

28 - 31 - 35

108 - 125 - 158 n/a

MMK-AP0093H1 n/a

1

2.8

3.2

320

1050

228

15

28 - 32 - 37

108 - 133 - 167 n/a

3/8”

1/4”

16 nom.

No

230 - 1 - 50

3

0.021

0.19

0.24

£746 n/a

£746

Communication cable - 2 core non polar 1.5mm

2

screened cable | Unit comes with infra red controller as standard

3/8”

1/4”

16 nom.

No

230 - 1 - 50

3

0.021

0.19

0.24

£757 n/a

£757

MMK-AP0123H1 n/a

1.25

3.6

4.0

320

1050

228

15

28 - 32 - 37

108 - 133 - 167 n/a

@amp_aircon | amp-air-conditioning 130

VRF Indoor

Wall Mounted 3 Series

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

V-Ph-Hz

A kW

A

A kW kW mm mm mm kg dB(A) l/s

Pa in in mm

1/2”

1/4”

16 nom.

No

230 - 1 - 50

3

0.043

0.32

0.41

£791 n/a

£791

MMK-AP0153H1 n/a

1.7

4.5

5.0

320

1050

228

15

33 - 36 - 41

150 - 183 - 233 n/a

MMK-AP0183H1 n/a

2

5.6

6.3

320

1050

228

15

33 - 36 - 41

150 - 183 - 233 n/a

1/2”

1/4”

16 nom.

No

230 - 1 - 50

3

0.043

0.32

0.41

£806 n/a

£806

Communication cable - 2 core non polar 1.5mm

2

screened cable | Unit comes with infra red controller as standard

5/8”

3/8”

16 nom.

No

230 - 1 - 50

3

0.050

0.37

0.47

£818 n/a

£818

MMK-AP0243H1 n/a

2.5

7.1

8.0

320

1050

228

15

34 - 39 - 46

158 - 208 - 283 n/a

RBC-AMS54E-ES £105 Retail

ampair.co.uk | 01707 378 670 | [email protected]

131

VRF Indoor

Wall Mounted 4 Series

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMK-AP0054MHP-E1 n/a

0.6

1.7

1.9

275

790

208

11

29 - 31 - 33

TBC n/a

3/8”

1/4”

16 od

No

230 - 1 - 50

3

TBC

TBC

TBC

£666 n/a

£666

MMK-AP0074MHP-E1 n/a

0.8

2.2

2.5

275

790

208

11

29 - 32 - 35

100 - 117 - 133 n/a

3/8”

1/4”

16 od

No

230 - 1 - 50

3

0.017

0.17

0.22

£676 n/a

£676

Communication cable - 2 core non polar 1.5mm

2

screened cable | Unit does not come with a controller as standard | 0054 unit only compatible with SMMSe outdoor units

@amp_aircon | amp-air-conditioning 132

VRF Indoor

Wall Mounted 4 Series

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

V-Ph-Hz

A kW

A

A kW kW mm mm mm kg dB(A) l/s

Pa in in mm

MMK-AP0094MHP-E1 n/a

1

2.8

3.2

275

790

208

11

29 - 33 - 36

100 - 125 - 142 n/a

3/8”

1/4”

16 od

No

230 - 1 - 50

3

0.018

0.18

0.23

£685 n/a

£685

MMK-AP0124MHP-E1 n/a

1.25

3.6

4.0

275

790

208

11

29 - 33 - 37

100 - 125 - 150 n/a

3/8”

1/4”

16 od

No

230 - 1 - 50

3

0.019

0.19

0.24

£698 n/a

£698

Communication cable - 2 core non polar 1.5mm

2

screened cable | Unit does not come with a controller as standard

RBC-AS41E £70 Retail

ampair.co.uk | 01707 378 670 | [email protected]

133

VRF Indoor

Ceiling Suspended

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMC-AP0157HP1-E n/a

1.7

4.5

5.0

235

950

690

23

28 - 34 - 36

150 - 200 - 233 n/a

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.033

0.36

0.54

£1,119 n/a

£1,119

MMC-AP0187HP1-E n/a

2

5.6

6.3

235

950

690

23

28 - 35 - 37

150 - 200 - 267 n/a

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.034

0.37

0.55

£1,238 n/a

£1,238

Communication cable - 2 core non polar 1.5mm

2

screened cable

@amp_aircon | amp-air-conditioning 134

VRF Indoor

Ceiling Suspended

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMC-AP0247HP1-E n/a

2.5

7.1

8.0

235

1270

690

29

29 - 36 - 41

217 - 283 - 400 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.067

0.65

0.97

£1,311 n/a

£1,311

MMC-AP0277HP1-E n/a

3

8.0

9.0

235

1270

690

29

29 - 36 - 41

217 - 283 - 400 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.067

0.65

0.97

£1,323 n/a

£1,323

Communication cable - 2 core non polar 1.5mm

2

screened cable

RBC-AMS54E-ES £105 Retail

ampair.co.uk | 01707 378 670 | [email protected]

135

VRF Indoor

Ceiling Suspended

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMC-AP0367HP1-E n/a

4

11.2

12.5

235

1586

690

35

32 - 38 - 44

283 - 383 - 517 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.083

0.77

1.16

£1,343 n/a

£1,343

MMC-AP0487HP1-E n/a

5

14.0

16.0

235

1586

690

35

35 - 41 - 44

333 - 433 - 514 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.083

0.77

1.16

£1,366 n/a

£1,366

Communication cable - 2 core non polar 1.5mm

2

screened cable

MMC-AP0567HP1-E n/a

6

16.0

18.0

235

1586

690

35

36 - 42 - 46

350 - 467 - 567 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.111

0.99

1.46

£1,463 n/a

£1,463

@amp_aircon | amp-air-conditioning 136

VRF Indoor

Floor Mounted Cabinet

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMF-AP0156H1-E n/a

1.7

4.5

5.0

1750

600

210

46

37 - 42 - 46

183 - 217 - 250 n/a

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.055

0.38

0.53

£1,313 n/a

£1,313

MMF-AP0186H1-E n/a

2

5.6

6.3

1750

600

210

46

37 - 42 - 46

183 - 217 - 250 n/a

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.055

0.38

0.53

£1,392 n/a

£1,392

Communication cable - 2 core non polar 1.5mm

2

screened cable

ampair.co.uk | 01707 378 670 | [email protected]

137

VRF Indoor

Floor Mounted Cabinet

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMF-AP0246H1-E n/a

2.5

7.1

8.0

1750

600

210

47

39 - 45 - 49

233 - 275 - 333 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.089

0.60

0.84

£1,453 n/a

£1,453

MMF-AP0276H1-E n/a

3

8.0

9.0

1750

600

210

47

39 - 45 - 49

233 - 275 - 333 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.089

0.60

0.84

£1,496 n/a

£1,496

Communication cable - 2 core non polar 1.5mm

2

screened cable

@amp_aircon | amp-air-conditioning 138

VRF Indoor

Floor Mounted Cabinet

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MMF-AP0366H1-E n/a

4

11.2

12.5

1750

600

390

62

41 - 46 - 51

383 - 450 - 533 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.135

0.90

1.26

£1,540 n/a

£1,540

MMF-AP0486H1-E n/a

5

14.0

16.0

1750

600

390

62

44 - 49 - 54

433 - 481 - 600 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.160

1.10

1.54

£1,618 n/a

£1,618

Communication cable - 2 core non polar 1.5mm

2

screened cable

MMF-AP0566H1-E n/a

6

16.0

18.0

1750

600

390

62

44 - 49 - 54

433 - 481 - 600 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.160

1.10

1.54

£1,698 n/a

£1,698

ampair.co.uk | 01707 378 670 | [email protected]

139

VRF Indoor

Floor Standing Chassis

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MML-AP0074BH1-E n/a

0.8

2.2

2.5

600

745

220

21

32 - 34 - 36

83 - 111 - 128

0

3/8”

1/4”

20 nom.

No

230 - 1 - 50

3

0.056

0.250

0.60

£769 n/a

£769

MML-AP0094BH1-E n/a

1

2.8

3.2

600

745

220

21

32 - 34 - 36

83 - 111 - 128

0

3/8”

1/4”

20 nom.

No

230 - 1 - 50

3

0.056

0.250

0.60

£789 n/a

£789

MML-AP0124BH1-E n/a

1.25

3.6

4.0

600

745

220

21

32 - 34 - 36

83 - 111 - 128

0

3/8”

1/4”

20 nom.

No

230 - 1 - 50

3

0.056

0.250

0.60

£812 n/a

£812

Communication cable - 2 core non polar 1.5mm

2

screened cable | Top discharge as standard, can be converted to front discharge

@amp_aircon | amp-air-conditioning 140

VRF Indoor

Floor Standing Chassis

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MML-AP0154BH1-E n/a

1.7

4.5

5.0

600

1045

220

29

32 - 34 - 36

136 - 167 - 206

0

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.090

0.450

0.80

£848 n/a

£848

MML-AP0184BH1-E n/a

2

5.6

6.3

600

1045

220

29

32 - 34 - 36

136 - 167 - 206

0

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.090

0.450

0.80

£903 n/a

£903

MML-AP0244BH1-E n/a

2.5

7.1

8.0

600

1045

220

29

33 - 37 - 42

178 - 219 - 264

0

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.095

0.460

1.00

£939 n/a

£939

Communication cable - 2 core non polar 1.5mm

2

screened cable | Top discharge as standard, can be converted to front discharge

RBC-AMT32E £50 Retail

ampair.co.uk | 01707 378 670 | [email protected]

141

VRF Indoor

Floor Standing Console

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MML-AP0074H1-E n/a

0.8

2.2

2.5

630

950

230

37

35 - 37 - 39

100 - 117 - 133 n/a

3/8”

1/4”

20 nom.

No

230 - 1 - 50

3

0.056

0.260

0.60

£922 n/a

£922

MML-AP0094H1-E n/a

1

2.8

3.2

630

950

230

37

35 - 37 - 39

100 - 117 - 133 n/a

3/8”

1/4”

20 nom.

No

230 - 1 - 50

3

0.056

0.260

0.60

£944 n/a

£944

Communication cable - 2 core non polar 1.5mm

2

screened cable

MML-AP0124H1-E n/a

1.25

3.6

4.0

630

950

230

37

38 - 41 - 45

181 - 217 - 250 n/a

3/8”

1/4”

20 nom.

No

230 - 1 - 50

3

0.092

0.430

0.80

£967 n/a

£967

@amp_aircon | amp-air-conditioning 142

VRF Indoor

Floor Standing Console

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MML-AP0154H1-E n/a

1.7

4.5

5.0

630

950

230

37

38 - 41 - 45

181 - 217 - 250 n/a

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.092

0.430

0.80

£1,016 n/a

£1,016

MML-AP0184H1-E n/a

2

5.6

6.3

630

950

230

37

39 - 44 - 49

217 - 258 - 300 n/a

1/2”

1/4”

20 nom.

No

230 - 1 - 50

3

0.102

0.470

1.10

£1,079 n/a

£1,079

Communication cable - 2 core non polar 1.5mm

2

screened cable

MML-AP0244H1-E n/a

2.5

7.1

8.0

630

950

230

37

39 - 44 - 49

217 - 258 - 300 n/a

5/8”

3/8”

20 nom.

No

230 - 1 - 50

3

0.102

0.470

1.10

£1,126 n/a

£1,126

RBC-AS41E £70 Retail

ampair.co.uk | 01707 378 670 | [email protected]

143

VRF Indoor

Floor Standing Bi Flow Console

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

kW kW mm mm mm kg dB(A) l/s

Pa in in mm

V-Ph-Hz

A kW

A

A

MML-AP0074NH1-E n/a

0.8

2.2

2.5

600

700

220

17

26 - 32 - 38

78 - 102 - 142 n/a

3/8”

1/4”

16 nom.

No

230 - 1 - 50

3

0.021

0.20

0.26

£960 n/a

£960

MML-AP0094NH1-E n/a

1

2.8

3.2

600

700

220

17

26 - 32 - 38

78 - 102 - 142 n/a

3/8”

1/4”

16 nom.

No

230 - 1 - 50

3

0.021

0.20

0.26

£1,034 n/a

£1,034

Communication cable - 2 core non polar 1.5mm

2

screened cable

MML-AP0124NH1-E n/a

1.25

3.6

4.0

600

700

220

17

29 - 34 - 40

90 - 113 - 153 n/a

3/8”

1/4”

16 nom.

No

230 - 1 - 50

3

0.025

0.23

0.30

£1,109 n/a

£1,109

@amp_aircon | amp-air-conditioning 144

VRF Indoor

Floor Standing Bi Flow Console

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-me-hi)

Airflow Rate (lo-me-hi)

SOUND & AIRFLOW

Static Pressure

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

V-Ph-Hz

A kW

A

A kW kW mm mm mm kg dB(A) l/s

Pa in in mm

MML-AP0154NH1-E n/a

1.7

4.5

5.0

600

700

220

17

31 - 37 - 43

107 - 130 - 173 n/a

1/2”

1/4”

16 nom.

No

230 - 1 - 50

3

0.034

0.29

0.38

£1,183 n/a

£1,183

MML-AP0184NH1-E n/a

2

5.6

6.3

600

700

220

17

34 - 40 - 47

118 - 147 - 202 n/a

1/2”

1/4”

16 nom.

No

230 - 1 - 50

3

0.052

0.42

0.55

£1,227 n/a

£1,227

Communication cable - 2 core non polar 1.5mm

2

screened cable

BMS-SM1280ETLE Smart Manager £2,000 Retail

ampair.co.uk | 01707 378 670 | [email protected]

145

AMP Air Conditioning

Field Based Staff

In addition to our offices in Welwyn Garden City and Bristol we have an extensive network of sales and technical support staff covering the UK.

All our field based team have an in-depth knowledge of our product ranges. They are supported by our central sales department so there is always someone availiable to help with your enquiry. We are committed to helping you select the most suitable system for your needs and budget to ensure that you receive comprehensive project support.

Our field based team can support you throughout the whole project process, including

»

On site surveys

»

Extensive product knowledge

»

Design advice and unit selections / quotations

»

Pipe work and wiring

schematics

»

Product documentation including O&M manuals

»

Advice on integrating our units with the latest control systems

»

Project support from conception to handover

Our team is further enhanced by experienced and highly qualified field based engineers.

With access to state of the art diagnostics tools, they are able to provide you with technical support whenever needed.

For further details or to arrange a meeting with your local team member please contact us on 01707 378 670 or email [email protected]

@amp_aircon | amp-air-conditioning 146

Air Handling & HRV

Air Handling & HRV

Air to Air Heat Exchangers with DX Coil

Indoor Unit

Remote Controller

Capacity Code

Fresh Air Conditioning Load (cooling)

Fresh Air Conditioning Load (heating)

Air Volume (extra high) m3/h - l/s

Air Volume (low) m3/h - l/s

Airflow Limit (upper) m3/h - l/s

Airflow Limit (lower) m3/h - l/s

Unit (height-width-depth)

Weight

Duct Diameter

External Static Pressure - extra high

External Static Pressure - high

External Static Pressure - low

Temperature Exchange Efficiency (H-L)

Enthalpy Exchange Efficiency cool (H-L)

Enthalpy Exchange Efficiency heat (H-L)

Sound Pressure Level - Extra High

Sound Pressure Level - High

Sound Pressure Level - Low

Pipe Sizes (gas - liquid)

Indoor Drain Connection

Water Pressure

Water Flow

Water Supply

Power Supply (V - Ph - Hz)

Power Consumption (eh - h - l)

Running Current (eh - h - l)

Suggested Fuse Size

Operating Range - around unit

Operating Range - outdoor air

Operating Range - return air

VN Unit

Remote Controller

Retail Price

kW kW

W

A

A mm kg mm

Pa

Pa

Pa

%

%

% mm

Mpa kg/h in dB(A) dB(A) dB(A) in

MMD-VN502HEX1E

NRC-01HE

1.0

4.10 (1.30)

5.53 (2.33)

500 - 139

440 - 122

600 - 167

330 - 92

430 - 1140 - 1690

84

200

120

105

115

70.5 - 71.5

56.5 - 57.5

68.5 - 69.0

37.5

36.5

34.5

3/8” - 1/4”

25 n/a n/a n/a

230 - 1 - 50

300 - 280 - 235

1.30 - 1.21 - 1.01

3

£3,193

£74

£3,267

Cooling and heating capacities are based upon the following conditions

Cooling: 27°CDB 19°CWB indoor, 35°CDB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilator

Heating: 20°CDB indoor, 7°CDB 6°CWB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilator

MMD-VN802HEX1E

NRC-01HE

1.7

6.56 (2.06)

8.61 (3.61)

800 - 222

640 - 178

960 - 267

480 - 133

430 - 1189 - 1739

100

250

120

100

100

70.0 - 72.5

56.0 - 59.0

70.0 - 73.0

41.0

40.0

38.0

1/2” - 1/4”

25 n/a n/a n/a

230 - 1 - 50

505 - 465 - 335

2.25 - 2.07 - 1.46

3

-10°C to 40°C 80% RH or less

-15°C to 43°C 80% RH or less

5°C to 40°C 80% RH or less

£4,654

£74

£4,728

MMD-VN1002HEX1E

NRC-01HE

2.0

8.25 (2.32)

10.92 (4.32)

950 - 264

820 - 278

1140 - 317

640 - 178

430 - 1189 - 1739

101

250

135

120

105

65.5 - 67.5

52.0 - 54.0

66.0 - 68.5

43.0

42.0

40.0

1/2” - 1/4”

25 n/a n/a n/a

230 - 1 - 50

550 - 545 - 485

2.46 - 2.43 - 2.16

3

£5,315

£74

£5,389

@amp_aircon | amp-air-conditioning 148

Air Handling & HRV

Air to Air Heat Exchangers with DX Coil & Humidifier

Indoor Unit

Remote Controller

Capacity Code

Fresh Air Conditioning Load (cooling)

Fresh Air Conditioning Load (heating)

Air Volume (extra high) m3/h - l/s

Air Volume (low) m3/h - l/s

Airflow Limit (upper) m3/h - l/s

Airflow Limit (lower) m3/h - l/s

Unit (height-width-depth)

Weight

Duct Diameter

External Static Pressure - extra high

External Static Pressure - high

External Static Pressure - low

Temperature Exchange Efficiency (H-L)

Enthalpy Exchange Efficiency cool. (H-L)

Enthalpy Exchange Efficiency heat. (H-L)

Sound Pressure Level - Extra High

Sound Pressure Level - High

Sound Pressure Level - Low

Pipe Sizes (gas - liquid)

Indoor Drain Connection

Water Pressure

Water Flow

Water Supply

Power Supply (V - Ph - Hz)

Power Consumption (eh - h - l)

Running Current (eh - h - l)

Suggested Fuse Size

Operating Range - around unit

Operating Range - outdoor air

Operating Range - return air

VN Unit

Remote Controller

Retail Price

kW kW mm kg mm

Pa

Pa

Pa

%

%

% dB(A) dB(A) dB(A) in mm

Mpa kg/h in

W

A

A

MMD-VNK502HEX1E

NRC-01HE

1.0

4.10 (1.30)

5.53 (2.33)

500 - 139

440 - 122

600 - 167

330 - 92

430 - 1140 - 1690

91

200

95

85

95

70.5 - 71.5

56.5 - 57.5

68.5 - 69.0

36.5

35.5

33.5

3/8” - 1/4”

25

0.02 - 0.49

3

1/2”

230 - 1 - 50

305 - 285 - 240

1.33 - 1.24 - 1.03

3

£3,605

£74

£3,679

Cooling and heating capacities are based upon the following conditions

Cooling: 27°CDB 19°CWB indoor, 35°CDB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilator

Heating: 20°CDB indoor, 7°CDB 6°CWB outdoor, the figures in ( ) indicate the heat reclaimed from the heat recovery ventilator

MMD-VNK802HEX1E

NRC-01HE

1.7

6.56 (2.06)

8.61 (3.61)

800 - 222

640 - 178

960 - 267

480 - 133

430 - 1189 - 1739

111

250

105

85

90

70.0 - 72.5

56.0 - 59.0

70.0 - 73.0

40.0

39.0

38.0

1/2” - 1/4”

25

0.02 - 0.49

5

1/2”

230 - 1 - 50

530 - 485 - 350

2.37 - 2.14 - 1.54

3

-10°C to 40°C 80% RH or less

-15°C to 43°C 80% RH or less

5°C to 40°C 80% RH or less

£5,247

£74

£5,321

MMD-VNK1002HEX1E

NRC-01HE

2.0

8.25 (2.32)

10.92 (4.32)

950 - 264

820 - 228

1140 - 317

640 - 178

430 - 1189 - 1739

112

250

110

90

115

65.5 - 67.5

52.0 - 54.0

66.0 - 68.5

42.0

41.0

39.0

1/2” - 1/4”

25

0.02 - 0.49

6

1/2”

230 - 1 - 50

575 - 565 - 520

2.56 - 2.51 - 2.31

5

£6,000

£74

£6,074

Humidification available during heating operation

The water quality of the humidifiers supply water should meet public waterworks standards and have a hardness of less than 100mg/l

If the water does not meet the above standard then you must use a deionizer.

ampair.co.uk | 01707 378 670 | [email protected]

149

Air Handling & HRV

Fresh Air Intake Units

Indoor Unit

Grille / Spigot Kit

Capacity Code

Nominal Cooling

Nominal Heating

Height

Width

Depth

Weight

Sound Pressure Level (lo-hi)

Airflow Rate (high)

SOUND & AIRFLOW

Static Pressure (lo-me-hi)

Gas Pipe Size

Liquid Pipe Size

Drain Connection

Internal Lift Pump

Power Supply

Suggested Fuse Size

Power Input

Running Current

Starting Current

Indoor Unit

Grille / Spigot Kit

Retail Price

Accessory

Drain Pump Option

Filter Box Option *

Pre Filter Option

65% Filter Option

90% Filter Option

Model

MMD-AP0481HFE

MMD-AP0721HFE

MMD-AP0961HFE

MMD-AP0481HFE

MMD-AP0721HFE

MMD-AP0961HFE

MMD-AP0481HFE

MMD-AP0721HFE

MMD-AP0961HFE

MMD-AP0481HFE

MMD-AP0721HFE

MMD-AP0961HFE

MMD-AP0481HFE

MMD-AP0721HFE

MMD-AP0961HFE

V-Ph-Hz

A kW

A

A kW kW mm mm mm kg dB(A) l/s

Pa in in mm

MMD-AP0481HFE n/a

5

14.0

8.9

492

892

1262

93

41 - 45

300

170 - 210 - 230

5/8”

3/8”

TBC

No

230 - 1 - 50

3

0.280

1.43

3.50

£1,854 n/a

£1,854

Part Number

TCB-DP31DE

TCB-DP32DE

TCB-FCY51DE

TCB-FCY100DE

TCB-PF1D-1E (2 REQ.)

TCB-PF3DE

TCB-UFM1D-1E (2 REQ.)

TCB-UFM3DE

TCB-UFH5D-1E (2 REQ.)

TCB-UFH7DE

MMD-AP0721HFE n/a

8

22.4

13.9

492

1392

1262

144

44 - 46

466

140 - 165 - 180

7/8”

1/2”

TBC

No

230 - 1 - 50

3

0.450

2.52

7.00

£3,070 n/a

£3,070

Retail Price

£809

£809

£331

£614

£46 Each

£158

£147 Each

£488

£152 Each

£504

MMD-AP0961HFE n/a

10

28.0

17.4

492

1392

1262

144

44 - 46

466

160 - 190 - 205

7/8”

1/2”

TBC

No

230 - 1 - 50

3

0.520

2.73

7.00

£3,243 n/a

£3,243

100% Fresh air units

Allows air to be pre-heated or pre-cooled

Only compatible with SMMSe

Not suitable for SHRMi or

Mini SMMS systems

Air must be pre-filtered

Total indoor unit + fresh air capacity must be 80 to 100% of outdoor unit capacity

Fresh air units can make up no more than 30% of total indoor capacity code

* The filter box can accommodate 2 filters - one of which must be a pre-filter.

Either but not both high efficiency filters may also be used in conjunction with the pre-filter

@amp_aircon | amp-air-conditioning 150

Air Handling & HRV

Heat Recovery Ventilation Units

VN Unit

Remote Controller

Air Volume (high) m3/h - l/s

Air Volume (low) m3/h - l/s

Unit (height-width-depth)

Weight

Duct Diameter

External Static Pressure - extra high

External Static Pressure - high

External Static Pressure - low

Filtration Efficiency Grade

Temperature Exchange Efficiency (H-L)

Sound Pressure Level - Extra High

Sound Pressure Level - High

Sound Pressure Level - Low

Power Supply (V - Ph - Hz)

Power Consumption - Extra High

Power Consumption - High

Power Consumption - Low

Operating Range - around unit

Operating Range - outdoor air

Operating Range - return air

VN Unit

Remote Controller

Retail Price

W

W

W

% dB(A) dB(A) dB(A)

Dimensions do not include electrical box 200mm mm kg mm

Pa

Pa

Pa

VN-M150HE

NRC-01HE

150 - 42

110 - 31

290 x 900 x 900

36

100

82 - 102

52 - 78

47 - 64

82%

81.5 - 83.0

26.0 - 28.0

24.0 - 25.5

20.0 - 22.0

230 - 1 - 50

68 - 78

59 - 67

42 - 47

£1,004

£74

£1,078

VN-M250HE

NRC-01HE

250 - 69

155 - 43

290 x 900 x 900

36

150

80 - 98

34 - 65

28 - 40

82%

87.0 - 81.5

29.5 - 30.0

25.0 - 27.0

21.0 - 22.0

230 - 1 - 50

123 - 138

99 - 111

52 - 59

-10°C to 40°C 80% RH or less

-15°C to 43°C 80% RH or less

5°C to 40°C 80% RH or less

£1,033

£74

£1,107

VN-M350HE

NRC-01HE

350 - 97

210 - 58

290 x 900 x 900

38

150

114 - 125

56 - 83

65 - 94

82%

74.5 - 79.5

34.0 - 35.0

30.0 - 32.0

27.0 - 29.0

230 - 1 - 50

165 - 182

135 - 145

82 - 88

£1,187

£74

£1,261

Accessory

Retail Price

RBC-VNL1

£50

RBC-VNMH1-PE

100mm heater kit for

VN-M150

£360

RBC-VNMH2-PE

150mm heater kit for

VN-M250-350

£360

RBC-VNMC-PE

Heater Kit Controller

£407

ampair.co.uk | 01707 378 670 | [email protected]

151

Air Handling & HRV

Heat Recovery Ventilation Units

VN Unit

Remote Controller

Air Volume (high) m3/h - l/s

Air Volume (low) m3/h - l/s

Unit (height-width-depth)

Weight

Duct Diameter

External Static Pressure - extra high

External Static Pressure - high

External Static Pressure - low

Filtration Efficiency Grade

Temperature Exchange Efficiency (H-L)

Sound Pressure Level - Extra High

Sound Pressure Level - High

Sound Pressure Level - Low

Power Supply (V - Ph - Hz)

Power Consumption - Extra High

Power Consumption - High

Power Consumption - Low

Operating Range - around unit

Operating Range - outdoor air

Operating Range - return air

VN Unit

Remote Controller

Retail Price

% dB(A) dB(A) dB(A)

W

W

W

Dimensions do not include electrical box 200mm mm kg mm

Pa

Pa

Pa

VN-M500HE

NRC-01HE

500 - 139

390 - 108

350 x 1140 x 1140

53

200

134 - 150

69 - 99

62 - 92

82%

76.5 - 78.0

32.5 - 34.0

29.5 - 31.0

26.0 - 29.0

230 - 1 - 50

214 - 238

176 - 192

128 - 142

£1,437

£74

£1,511

VN-M650HE

NRC-01HE

650 - 180

520 - 144

350 x 1140 x 1140

53

200

91 - 107

58 - 82

61 - 96

82%

75.0 - 76.5

34.0 - 36.0

33.0 - 34.0

31.0 - 32.5

230 - 1 - 50

262 - 290

240 - 258

178 - 191

-10°C to 40°C 80% RH or less

-15°C to 43°C 80% RH or less

5°C to 40°C 80% RH or less

£1,597

£74

£1,671

VN-M800HE

NRC-01HE

800 - 222

700 - 194

400 x 1189 x 1189

70

250

142 - 158

102 - 132

76 - 112

82%

76.5 - 77.5

37.0 - 38.5

35.5 - 37.0

33.5 - 35.0

230 - 1 - 50

360 - 383

339 - 353

286 - 300

£1,870

£74

£1,944

Accessory

Retail Price

RBC-VNL1

£50

RBC-VNMH3-PE

200mm heater kit for

VN-M500-650

£417

RBC-VNMH4-PE

250mm heater kit for

VN-M800-1000

£417

RBC-VNMC-PE

Heater Kit Controller

£407

@amp_aircon | amp-air-conditioning 152

Air Handling & HRV

Heat Recovery Ventilation Units

VN Unit

Remote Controller

Air Volume (high) m3/h - l/s

Air Volume (low) m3/h - l/s

Unit (height-width-depth)

Weight

Duct Diameter

External Static Pressure - extra high

External Static Pressure - high

External Static Pressure - low

Filtration Efficiency Grade

Temperature Exchange Efficiency (H-L)

Sound Pressure Level - Extra High

Sound Pressure Level - High

Sound Pressure Level - Low

Power Supply (V - Ph - Hz)

Power Consumption - Extra High

Power Consumption - High

Power Consumption - Low

Operating Range - around unit

Operating Range - outdoor air

Operating Range - return air

VN Unit

Remote Controller

Retail Price

W

W

W

% dB(A) dB(A) dB(A)

Dimensions do not include electrical box 200mm mm kg mm

Pa

Pa

Pa

VN-M1000HE

NRC-01HE

1000 - 278

755 - 210

400 x 1189 x 1189

70

250

130 - 150

97 - 122

84 - 127

82%

73.5 - 77.0

39.5 - 40.5

38.5 - 40.0

34.0 - 35.5

230 - 1 - 50

532 - 569

494 - 538

353 - 370

£2,076

£74

£2,150

VN-M1500HE

NRC-01HE

1500 - 417

1200 - 333

810 x 1189 x 1189

143

250

135 - 156

103 - 129

112 - 142

82%

76.5 - 79.0

38.0 - 39.0

36.5 - 37.5

36.0 - 37.5

230 - 1 - 50

751 - 786

708 - 784

570 - 607

-10°C to 40°C 80% RH or less

-15°C to 43°C 80% RH or less

5°C to 40°C 80% RH or less

£3,942

£74

£4,016

VN-M2000HE

NRC-01HE

2000 - 556

1400 - 389

810 x 1189 x 1189

143

250

124 - 143

92 - 116

110 - 143

82%

73.5 - 77.5

41.0 - 42.5

39.5 - 41.0

37.0 - 38.0

230 - 1 - 50

1084 - 1154

1032 - 1080

702 - 742

£4,331

£74

£4,405

Accessory

Description

Retail Price

RBC-VNL1

VN unit wiring interface for remote on-off

£50

ampair.co.uk | 01707 378 670 | [email protected]

153

Air Handling & HRV

VRF Air Handling Unit Interface

DX Controller Model

DX Valve Kit Model

Capacity Code

Nominal Cooling Capacity

Nominal Heating Capacity

Controller unit height

Controller unit width

Controller unit depth

Controller unit weight

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Evaporating Temperature Range

Suction Superheat

Condensing Temperature

Power Supply

Suggested Fuse Size

DX Controller

DX Valve Kit

Retail Price

kW kW mm mm mm mm m 3 /hr cm

3 in

°C

K

°C

V-Ph-Hz

A

MM-DXC010

MM-DXV080

2

5.6

6.3

400

300

150

8

720 - 1080

800 - 1100

3/8”

4 - 6

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

MM-DXC010

MM-DXV080

2.5

7.1

8.0

400

300

150

8

1060 - 1580

1000 - 1400

3/8”

6 - 8

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

MM-DXC010

MM-DXV080

3

8.0

9.0

400

300

150

8

1060 - 1580

1000 - 1400

3/8”

6 - 8

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

MM-DXC010

MM-DXV140

4

11.2

12.5

400

300

150

8

1280 - 1920

1500 - 2100

3/8”

6 - 10

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

For Multi-Circuit DX coil; applications outdoor units can be combined up to 48HP by the inclusion of the

DXC012 follower panel(s) £440 each, contact AMP for details

Allows connection of a 3rd party AHU unit to all Toshiba VRF products using a locally supplied DX coil

Control is achieved using a standard Toshiba remote controller (RBC-AMT32E)

Compatible with Toshiba control accessories

External on/off input

Safety cut out input to detect fan failure

Multi-Circuit combinations also available.

Contact AMP for more information.

@amp_aircon | amp-air-conditioning 154

Air Handling & HRV

VRF Air Handling Unit Interface

DX Controller Model

DX Valve Kit Model

Capacity Code

Nominal Cooling Capacity

Nominal Heating Capacity

Controller unit height

Controller unit width

Controller unit depth

Controller unit weight

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Evaporating Temperature Range

Suction Superheat

Condensing Temperature

Power Supply

Suggested Fuse Size

DX Controller

DX Valve Kit

Retail Price

kW kW mm mm mm mm m 3 /hr cm 3 in

°C

K

°C

V-Ph-Hz

A

MM-DXC010

MM-DXV140

5

14.0

16.0

400

300

150

8

1680 - 2520

1700 - 2700

3/8”

8 - 12

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

MM-DXC010

MM-DXV140

6

16.0

18.0

400

300

150

8

1850 - 3740

1700 - 3200

3/8”

8 - 12

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

MM-DXC010

MM-DXV280

8

22.4

25.0

400

300

150

8

2880 - 4320

3000 - 4200

3/8”

10 - 12

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

MM-DXC010

MM-DXV280

10

28.0

31.5

400

300

150

8

3360 - 5040

3000 - 5400

3/8”

10 - 12

6.5

5

52

230 - 1 - 50

6

£583

£338

£921

For Multi-Circuit DX coil; applications outdoor units can be combined up to 48HP by the inclusion of the

DXC012 follower panel(s) £440 each, contact AMP for details

Allows connection of a 3rd party AHU unit to all Toshiba VRF products using a locally supplied DX coil

Control is achieved using a standard Toshiba remote controller (RBC-AMT32E)

Compatible with Toshiba control accessories

External on/off input

Safety cut out input to detect fan failure

ampair.co.uk | 01707 378 670 | [email protected]

155

Air Handling & HRV

Air Handling Unit Interface for Digital Inverters

Outdoor Unit

AHU Interface

Remote Controller

Cooling Capacity Range

Heating Capacity Range

Outdoor Unit - Height

Outdoor Unit - Width

Outdoor Unit - Depth

Outdoor Unit - Weight

Outdoor Unit Air Flow

OU Sound Pressure Level Cool - Heat

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Power Supply

Running Current

Suggested Fuse Size

Outdoor Unit

AHU Interface

Remote Controller

Retail Price

m kg in m kW kW mm mm mm mm l/s dB(A) m 3 /hr cm 3 in

V-Ph-Hz

A

A

RAV-SM304ATP-E

RBC-AHU1

RBC-AMS41E

0.9 - 3.0

0.8 - 4.5

550

780

290

33

500

46 - 47

480 - 660

TBC

3/8”

4

3/8” - 1/4”

2 - 20

15

0.8 - 20g/m

Yes

230 - 1 - 50

3.86

10

£588

RAV-SM404ATP-E

RBC-AHU1

RBC-AMS41E

0.9 - 4.0

0.8 - 5.0

550

780

290

39

616

49 - 50

522 - 690

TBC

3/8”

4 - 6

1/2” - 1/4”

2 - 20

15

1.4 - 20g/m

Yes

230 - 1 - 50

5.14

10

£704

£461

£66

£461

£66

£461

£66

£1,115 £1,231 £1,367

Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)

RAV-SM564ATP-E

RBC-AHU1

RBC-AMS41E

1.5 - 5.6

1.5 - 6.3

550

780

290

40

667

46 - 48

480 - 1100

500 - 1500

3/8”

4 - 6

1/2” - 1/4”

5 - 30

20

1.1 - 20g/m

Yes

230 - 1 - 50

8.95

16

£840

@amp_aircon | amp-air-conditioning 156

Air Handling & HRV

Air Handling Unit Interface for Digital Inverters

Outdoor Unit

AHU Interface

Remote Controller

Cooling Capacity Range

Heating Capacity Range

Outdoor Unit - Height

Outdoor Unit - Width

Outdoor Unit - Depth

Outdoor Unit - Weight

Outdoor Unit Air Flow

OU Sound Pressure Level Cool - Heat

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Power Supply

Running Current

Suggested Fuse Size

Outdoor Unit

AHU Interface

Remote Controller

Retail Price

in m m kg l/s dB(A) m 3 /hr cm 3 in kW kW mm mm mm mm

V-Ph-Hz

A

A

RAV-SM804ATP-E

RBC-AHU1

RBC-AMS41E

1.5 - 8.0

1.5 - 9.0

550

780

290

44

750

48 - 52

700 - 1500

800 - 2400

3/8”

6 - 8

5/8” - 3/8”

5 - 30

20

1.7 - 40g/m

Yes

230 - 1 - 50

11.43

16

£1,177

RAV-SM1104ATP-E

RBC-AHU1

RBC-AMS41E

3.0 - 11.2

3.0 - 13.0

890

900

320

68

1133

53 - 54

1260 - 2500

1000 - 3000

3/8”

6 - 10

5/8” - 3/8”

5 - 30

30

2.8 - 40g/m

Yes

230 - 1 - 50

15.18

20

£1,549

£461

£66

£461

£66

£461

£66

£1,704 £2,076 £2,160

Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)

RAV-SM1404ATP-E

RBC-AHU1

RBC-AMS41E

3.0 - 13.2

3.0 - 16.0

890

900

320

68

1166

54 - 55

1260 - 2750

1250 - 3750

3/8”

8 - 12

5/8” - 3/8”

5 - 50

30

2.8 - 40g/m

Yes

230 - 1 - 50

21.37

32

£1,633

ampair.co.uk | 01707 378 670 | [email protected]

157

Air Handling & HRV

Air Handling Unit Interface for Digital Inverters

Outdoor Unit

AHU Interface

Remote Controller

Cooling Capacity Range

Heating Capacity Range

Outdoor Unit - Height

Outdoor Unit - Width

Outdoor Unit - Depth

Outdoor Unit - Weight

Outdoor Unit Air Flow

OU Sound Pressure Level Cool - Heat

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Power Supply

Running Current

Suggested Fuse Size

Outdoor Unit

AHU Interface

Remote Controller

Retail Price

m kg in m kW kW mm mm mm mm l/s dB(A) m 3 /hr cm 3 in

V-Ph-Hz

A

A

RAV-SM1603AT-E

RBC-AHU1

RBC-AMS41E

3.0 - 16.0

3.0 - 16.0

1340

900

320

99

1717

51 - 53

1260 - 3000

1400 - 4200

3/8”

8 - 12

5/8” - 3/8”

5 - 50

30

3.1 - 40g/m

Yes

230 - 1 - 50

21.70

32

£2,059

RAV-SM2244AT8-E

RBC-AHU1

RBC-AMS41E

9.8 - 22.4

9.8 - 25.0

1540

900

320

134

2217

56 - 57

2880 - 4320

2000 - 6000

3/8”

10 - 12

1 1/8” - 1/2”

5 - 75

30

5.9 - 80g/m

Yes

400 - 3 - 50

13.33 per phase

16 per phase

£3,000

£461

£66

£461

£66

£461

£66

£2,586 £3,527 £3,622

Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)

RAV-SM2804T8-E

RBC-AHU1

RBC-AMS41E

9.8 - 27.0

9.8 - 31.5

1540

900

320

134

2217

57 - 58

3360 - 5040

2500 - 7500

3/8”

10 - 12

1 1/8” - 1/2”

5 - 75

30

5.9 - 80g/m

Yes

400 - 3 - 50

15.83 per phase

20 per phase

£3,095

@amp_aircon | amp-air-conditioning 158

Air Handling & HRV

Air Handling Unit Interface for Super Digital Inverters

Outdoor Unit

AHU Interface

Remote Controller

Cooling Capacity Range

Heating Capacity Range

Outdoor Unit - Height

Outdoor Unit - Width

Outdoor Unit - Depth

Outdoor Unit - Weight

Outdoor Unit Air Flow

OU Sound Pressure Level Cool - Heat

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Power Supply

Running Current

Suggested Fuse Size

Outdoor Unit

AHU Interface

Remote Controller

Retail Price

in m m kg l/s dB(A) m 3 /hr cm 3 in kW kW mm mm mm mm

V-Ph-Hz

A

A

RAV-SP404AT-E

RBC-AHU1

RBC-AMS41E

1.5 - 4.0

1.5 - 5.0

550

780

290

40

667

45 - 47

480 - 880

350 - 1050

3/8”

4

1/2” - 1/4”

5 - 50

20

1.0 - 20g/m

Yes

230 - 1 - 50

4.98

10

£998

RAV-SP564ATP-E

RBC-AHU1

RBC-AMS41E

1.2 - 5.6

0.9 - 8.1

550

780

290

44

667

47 - 48

480 - 1100

500 - 1500

3/8”

4 - 6

1/2” - 1/4”

5 - 50

20

1.4 - 20g/m

Yes

230 - 1 - 50

6.55

16

£1,097

£461

£66

£461

£66

£461

£66

£1,525 £1,624 £2,155

Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)

RAV-SP804ATP-E

RBC-AHU1

RBC-AMS41E

1.9 - 8.0

1.3 - 11.3

890

900

320

66

833

48 - 49

700 - 1500

800 - 2400

3/8”

6 - 8

5/8” - 3/8”

5 - 50

30

2.1 - 40g/m

Yes

230 - 1 - 50

9.02

16

£1,628

ampair.co.uk | 01707 378 670 | [email protected]

159

Air Handling & HRV

Air Handling Unit Interface for Super Digital Inverters

Outdoor Unit

AHU Interface

Remote Controller

Cooling Capacity Range

Heating Capacity Range

Outdoor Unit - Height

Outdoor Unit - Width

Outdoor Unit - Depth

Outdoor Unit - Weight

Outdoor Unit Air Flow

OU Sound Pressure Level Cool - Heat

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Power Supply

Running Current

Suggested Fuse Size

Outdoor Unit

AHU Interface

Remote Controller

Retail Price

m kg in m kW kW mm mm mm mm l/s dB(A) m 3 /hr cm 3 in

V-Ph-Hz

A

A

RAV-SP1104AT-E

RBC-AHU1

RBC-AMS41E

2.6 - 12.0

2.4 - 13.0

1340

900

320

93

1683

49 - 50

1260 - 2500

1000 - 3000

3/8”

6 - 10

5/8” - 3/8”

3 - 75

30

3.1 - 40g/m

Yes

230 - 1 - 50

10.43

16

£1,995

RAV-SP1104AT8-E

RBC-AHU1

RBC-AMS41E

2.6 - 12.0

2.4 - 13.0

1340

900

320

93

1683

49 - 50

1260 - 2500

1000 - 3000

3/8”

6 - 10

5/8” - 3/8”

3 - 75

30

3.1 - 40g/m

Yes

400 - 3 - 50

3.72 per phase

10 per phase

£2,184

£461

£66

£461

£66

£2,522 £2,711

Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)

@amp_aircon | amp-air-conditioning 160

Air Handling & HRV

Air Handling Unit Interface for Super Digital Inverters

Outdoor Unit

AHU Interface

Remote Controller

Cooling Capacity Range

Heating Capacity Range

Outdoor Unit - Height

Outdoor Unit - Width

Outdoor Unit - Depth

Outdoor Unit - Weight

Outdoor Unit Air Flow

OU Sound Pressure Level Cool - Heat

Hex Air Volume

Hex Coil Volume

Hex Coil Diameter

Hex Paths

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Pre-charged for

Charge R410A (Factory - Additional)

Suitable for Replacement Tech.

Power Supply

Running Current

Suggested Fuse Size

Outdoor Unit

AHU Interface

Remote Controller

Retail Price

in m m kg l/s dB(A) m 3 /hr cm 3 in kW kW mm mm mm mm

V-Ph-Hz

A

A

RAV-SP1404AT-E

RBC-AHU1

RBC-AMS41E

2.6 - 14.0

2.4 - 16.5

1340

900

320

95

1717

51 - 52

1260 - 2750

1250 - 3750

3/8”

8 - 12

5/8” - 3/8”

3 - 75

30

3.1 - 40g/m

Yes

230 - 1 - 50

15.76

25

£2,205

RAV-SP1404AT8-E

RBC-AHU1

RBC-AMS41E

2.6 - 14.0

2.4 - 16.5

1340

900

320

95

1717

51 - 52

1260 - 2750

1250 - 3750

3/8”

8 - 12

5/8” - 3/8”

3 - 75

30

3.1 - 40g/m

Yes

400 - 3 - 50

5.42 per phase

16 per phase

£2,279

£461

£66

£461

£66

£461

£66

£2,732 £2,806 £2,953

Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB)

RAV-SP1604AT8-E

RBC-AHU1

RBC-AMS41E

2.6 - 16.0

2.4 - 19.0

1340

900

320

95

1717

51 - 53

1260 - 3000

1400 - 4200

3/8”

8 - 12

5/8” - 3/8”

3 - 75

30

3.1 - 40g/m

Yes

400 - 3 - 50

6.66 per phase

16 per phase

£2,426

ampair.co.uk | 01707 378 670 | [email protected]

161

“It’s always a pleasure to do business with AMP - they provide a great level of personal customer service and are always willing to go the extra mile.”

Tim Church -

Calibre Climate Control

Photo: Sarah Smith, Internal Sales Administrator at AMP

@amp_aircon | amp-air-conditioning 162

Applied & Air to Water

CIAT installation at Queen Mary University courtesy of Hawkes Refrigeration

Applied Products & Air to Water

CIAT Products

AMP have been recognised as a Toshiba Platinum Partner. As such AMP can now offer the complete range of CIAT products to the UK market.

CIAT supplies an extensive range of high performance chillers, air handling units, fan coils and heat pumps.

The complete CIAT range includes

»

Air to water heat pumps and water chillers

»

Water to water heat pumps and water chillers

»

Fan coil units

»

Air handling units

»

Roof top packaged units

»

Dry coolers

»

Thermal energy storage

Aquaciat Power, Air to Water 190 - 657kW

CIAT Chillers and heat pumps are designed and manufactured at their European sites in ultra-modern industrial plants, thereby benefiting from all the group’s industrial resources.

With over 80 years experience, more than 2,000 employees and 6 production sites, CIAT has obtained ISO

14001 certification and is renowned as a major player in the HVAC industry.

ClimaCIAT Airtop Air Handling Unit up to 17,000m3/h

Major Line Cased Unit - 0.7 - 11.0kW

CIAT’s UK operation has moved to new headquarters alongside Toshiba in Leatherhead. This new CIAT base will include a dedicated air conditioning training centre with working equipment, a show room and administration offices for technical support and sales staff.

Equipment will be stocked and distributed from

Toshiba’s UK logistics hub at Plymouth.

@amp_aircon | amp-air-conditioning 164

Applied Products & Air to Water

CIAT Products

CIAT chiller installation at Queen Mary University

Courtesy of Hawkes Refrigeration

The first CIAT chiller to be supplied by Toshiba distributor

AMP Air has been installed at Queen Mary University of

London.

The AquaCIAT 2 Evolution chiller was installed by

Basildon-based Hawkes Refrigeration Engineers at the

John Vane Science Centre, the world-renowned cancer research centre on the University’s Charterhouse campus.

The installation was part of a major replacement and upgrade of the building’s air conditioning system.

It had previously relied on an ageing split system, using a water chiller linked to remote condensing units.

The packaged air-cooled CIAT chiller, with a capacity of

141kW of cooling, is equipped with optional inverter-controlled variable speed pumps for improved efficiency, delivering an EER of 3.09 and SEER of 4.06.

The R410A-based system running on scroll compressors is designed to allow for future expansion as part of a staged replacement process. This includes the use of

6in diameter chilled water pipework and a 10in low-loss header to permit the addition of up to three further

Toshiba/CIAT chillers, one of which would be on standby.

Given the sensitive research environment, the chiller is equipped with enhanced acoustic insulation in order to minimise noise in the vicinity of the installation.

For further details please contact us on

01707 378 670 or email [email protected]

ampair.co.uk | 01707 378 670 | [email protected]

165

Applied Products & Air to Water

Air Curtain - Free Hanging - Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating) kW mm m

OUTDOOR UNIT SPECIFICATION

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) m m kg kg l/s dB(A) mm kg

Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

V-Ph-Hz

A

A

RAV-CT101CH-M RAV-CT101CH-L RAV-CT151CH-M RAV-CT151CH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SM804ATP-E RAV-SM804ATP-E RAV-SM1104ATP-ERAV-SM1104ATP-E

3

8.0

2.46

1000

3.0

3

8.0

2.52

1000

3.2

4

11.2

2.44

1500

3.0

4

11.2

2.65

1500

3.2

260 - 1210 - 490 260 - 1210 - 490 260 - 1710 - 490 260 - 1710 - 490

54 57 85 87

422

54

583

55

633

55

778

56

550 - 780 - 290

44

550 - 780 - 290 890 - 900 - 320

44 68

46°C to -15°C / 15°C to -15°C

890 - 900 - 320

68

750

48 - 52

5/8” - 3/8”

5 - 30

30

20

1.7 - 40g/m

750

48 - 52

5/8” - 3/8”

5 - 30

30

20

1.7 - 40g/m

1133

53 - 54

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

1133

53 - 54

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

15.18

20

230 - 1 - 50

3 core & earth

15.18

20

£4,157

£66

£4,687

£66

£5,253

£66

£5,523

£66

£1,177

£5,400

£1,177

£5,930

£1,549

£6,868

£1,549

£7,138

Suitable for installation above the door where whole unit will be visible

Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48

Ceiling mounting kit for model 25, part number 4034 retail price £65

@amp_aircon | amp-air-conditioning 166

Applied Products & Air to Water

Air Curtain - Free Hanging - Digital Inverter

OUTDOOR UNIT SPECIFICATION

Air Curtain

Outdoor Unit

Retail Price

RAV-CT201CH-M RAV-CT201CH-L RAV-CT251CH-M RAV-CT251CH-L

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating)

Standard Airflow

Power Supply

Interconnecting Cables

Air Curtain

Remote Controller kW mm m kg l/s dB(A) mm kg l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional)

Maximum Running Current

Suggested Fuse Size in m m m kg

V-Ph-Hz

A

A

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SM1404ATP-ERAV-SM1404ATP-E RAV-SM1603AT-E RAV-SM1603AT-E

5

14.0

2.63

2000

5

14.0

2.82

2000

6

16.0

3.12

2500

6

16.0

3.27

2500

3.0

3.2

3.0

3.2

260 - 2210 - 490 260 - 2210 - 490 260 - 2710 - 490 260 - 2710 - 490

115

844

56

890 - 900 - 320

68

1167

54 - 55

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

117

1167

57

890 - 900 - 320

147

1056

57

1340 - 900 - 320 1340 - 900 - 320

68 99

46°C to -15°C / 15°C to -15°C

1167 1717

54 - 55

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

51 - 53

5/8” - 3/8”

5 - 50

30

30

3.1 - 40g/m

149

1361

58

99

1717

51 - 53

5/8” - 3/8”

5 - 50

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

21.37

32

230 - 1 - 50

3 core & earth

21.37

32

230 - 1 - 50

3 core & earth

21.70

32

230 - 1 - 50

3 core & earth

21.70

32

£6,020

£66

£6,834

£66

£6,841

£66

£7,159

£66

£1,633

£7,719

£1,633

£8,533

£2,059

£8,966

£2,059

£9,284

Suitable for installation above the door where whole unit will be visible

Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48

Ceiling mounting kit for model 25, part number 4034 retail price £65

RBC-AMS54E-ES £105 Retail

ampair.co.uk | 01707 378 670 | [email protected]

167

Applied Products & Air to Water

Air Curtain - Free Hanging - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating) kW mm m

OUTDOOR UNIT SPECIFICATION

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) m m kg kg l/s dB(A) mm kg

V-Ph-Hz Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

A

A

RAV-CT101CH-M RAV-CT101CH-L RAV-CT151CH-M RAV-CT151CH-M

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP804ATP-E RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1104AT8-E

3

8.0

2.46

1000

3.0

3

8.0

2.52

1000

3.2

4

11.2

2.44

1500

3.0

4

11.2

2.44

1500

3.0

260 - 1210 - 490 260 - 1210 - 490 260 - 1710 - 490 260 - 1710 - 490

54 57 85 85

422

54

583

55

633

55

633

55

550 - 780 - 290

44

750

48 - 52

5/8” - 3/8”

5 - 50

30

30

1.7 - 40g/m

550 - 780 - 290

44

750

48 - 52

5/8” - 3/8”

5 - 30

30

30

1.7 - 40g/m

1340 - 900 - 320 1340 - 900 - 320

93

43°C to -15°C / 15°C to -15°C

1683

49 - 50

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

95

1683

49 - 50

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

10.43

16

400 - 3 - 50

3 core & earth

3.72 per Ph

10 per Ph

£4,157

£66

£4,687

£66

£5,253

£66

£5,253

£66

£1,628

£5,851

£1,628

£6,381

£1,995

£7,314

£2,184

£7,503

Suitable for installation above the door where whole unit will be visible

Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48

Ceiling mounting kit for model 25, part number 4034 retail price £65

@amp_aircon | amp-air-conditioning 168

Applied Products & Air to Water

Air Curtain - Free Hanging - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight kW mm m

OUTDOOR UNIT SPECIFICATION

Operating Range (Cooling - Heating)

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) kg l/s dB(A) mm kg m m kg

V-Ph-Hz Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

A

A

RAV-CT151CH-L RAV-CT151CH-L RAV-CT201CH-M RAV-CT201CH-M

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP1104AT-E RAV-SP1104AT8-E RAV-SP1404AT-E RAV-SP1404AT8-E

4

11.2

2.65

1500

4

11.2

2.65

1500

5

14.0

2.63

2000

5

14.0

2.63

2000

3.2

3.2

3.0

3.0

260 - 1710 - 490 260 - 1710 - 490 260 - 2210 - 490 260 - 2210 - 490

87

778

87

778

115

844

115

844

56 56 56 56

1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320

93 95

1683

49 - 50

5/8” - 3/8”

3 - 75

95 93

46°C to -15°C / 15°C to -15°C

1683 1717

49 - 50

5/8” - 3/8”

3 - 75

30

51 - 52

5/8” - 3/8”

3 - 75

30

1717

51 - 52

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

30

3.1 - 40g/m

30

3.1 - 40g/m

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

10.43

16

400 - 3 - 50

3 core & earth

3.72 per Ph

10 per Ph

230 - 1 - 50

3 core & earth

15.76

25

400 - 3 - 50

3 core & earth

5.42 per Ph

16 per Ph

£5,523

£66

£5,523

£66

£6,020

£66

£6,020

£66

£1,995

£7,584

£2,184

£7,773

£2,205

£8,291

£2,279

£8,365

Suitable for installation above the door where whole unit will be visible

Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48

Ceiling mounting kit for model 25, part number 4034 retail price £65

RBC-AS41E £70 Retail

ampair.co.uk | 01707 378 670 | [email protected]

169

Applied Products & Air to Water

Air Curtain - Free Hanging - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating) kW mm m

OUTDOOR UNIT SPECIFICATION

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) m m kg kg l/s dB(A) mm kg

V-Ph-Hz Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

A

A

RAV-CT201CH-L RAV-CT201CH-L RAV-CT251CH-M RAV-CT251CH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E RAV-SP1604AT8-E

5

14.0

2.82

2000

3.2

5

14.0

2.82

2000

3.2

6

16.0

3.12

2500

3.0

6

16.0

3.27

2500

3.2

260 - 2210 - 490 260 - 2210 - 490 260 - 2710 - 490 260 - 2710 - 490

117 117 147 149

1167

57

1167

57

1056

57

1361

58

1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320

93 95 95

43°C to -15°C / 15°C to -15°C

95

1717

51 - 52

1717

51 - 52

1717

51 - 53

1717

51 - 53

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

15.76

25

400 - 3 - 50

3 core & earth

5.42 per Ph

16 per Ph

400 - 3 - 50

3 core & earth

6.66 per Ph

16 per Ph

400 - 3 - 50

3 core & earth

6.66 per Ph

16 per Ph

£6,834

£66

£6,834

£66

£6,841

£66

£7,159

£66

£2,205

£9,105

£2,279

£9,179

£2,426

£9,333

£2,426

£9,651

Suitable for installation above the door where whole unit will be visible

Ceiling mounting kit for model 100 to 200, part number 3871 retail price £48

Ceiling mounting kit for model 25, part number 4034 retail price £65

@amp_aircon | amp-air-conditioning 170

Applied Products & Air to Water

Air Curtain - Cassette Type - Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight kW mm m

OUTDOOR UNIT SPECIFICATION

Operating Range (Cooling - Heating)

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) kg l/s dB(A) mm kg m m kg

Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

V-Ph-Hz

A

A

RAV-CT101UH-M RAV-CT101UH-L RAV-CT151UH-M RAV-CT151UH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SM804ATP-E RAV-SM804ATP-E RAV-SM1104ATP-ERAV-SM1104ATP-E

3

8.0

2.46

1000

3

8.0

2.52

1000

4

11.2

2.44

1500

4

11.2

2.65

1500

3.0

3.2

3.0

3.2

260 - 1050 - 780 260 - 1050 - 780 260 - 1550 - 780 260 - 1550 - 780

49

422

54

550 - 780 - 290

44

52

583

55

550 - 780 - 290

105

633

55

890 - 900 - 320

44 68

46°C to -15°C / 15°C to -15°C

750 1133

107

778

56

890 - 900 - 320

68

750

48 - 52

5/8” - 3/8”

5 - 30

30

20

1.7 - 40g/m

48 - 52

5/8” - 3/8”

5 - 30

30

20

1.7 - 40g/m

53 - 54

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

1133

53 - 54

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

15.18

20

230 - 1 - 50

3 core & earth

15.18

20

£4,351

£66

£4,994

£66

£5296

£66

£5,687

£66

£1,177

£5,594

£1,177

£6,237

£1,549

£6,911

£1,549

£7,302

Suitable for recessed installation

ampair.co.uk | 01707 378 670 | [email protected]

171

Applied Products & Air to Water

Air Curtain - Cassette Type - Digital Inverter

OUTDOOR UNIT SPECIFICATION

Air Curtain

Outdoor Unit

Retail Price

RAV-CT201UH-M RAV-CT201UH-L RAV-CT251UH-M RAV-CT251UH-L

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating)

Standard Airflow

Power Supply

Interconnecting Cables

Air Curtain

Remote Controller kW mm m kg l/s dB(A) mm kg l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional)

Maximum Running Current

Suggested Fuse Size in m m m kg

V-Ph-Hz

A

A

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SM1404ATP-ERAV-SM1404ATP-E RAV-SM1603AT-E RAV-SM1603AT-E

5

14.0

2.63

2000

5

14.0

2.82

2000

6

16.0

3.12

2500

6

16.0

3.27

2500

3.0

3.2

3.0

3.2

260 - 2050 - 780 260 - 2050 - 780 260 - 2550 - 780 260 - 2550 - 780

111

844

56

890 - 900 - 320

68

1167

54 - 55

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

113

1167

57

890 - 900 - 320

135

1056

57

1340 - 900 - 320 1340 - 900 - 320

68 99

46°C to -15°C / 15°C to -15°C

1167 1717

54 - 55

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

51 - 53

5/8” - 3/8”

5 - 50

30

30

3.1 - 40g/m

137

1361

58

99

1717

51 - 53

5/8” - 3/8”

5 - 50

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

21.37

32

230 - 1 - 50

3 core & earth

21.37

32

230 - 1 - 50

3 core & earth

21.70

32

230 - 1 - 50

3 core & earth

21.70

32

£6,107

£66

£6,887

£66

£6,891

£66

£7,626

£66

£1,633

£7,806

£1,633

£8,586

£2,059

£9,016

£2,059

£9,751

Suitable for recessed installation

@amp_aircon | amp-air-conditioning 172

Applied Products & Air to Water

Air Curtain - Cassette Type - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight kW mm m

OUTDOOR UNIT SPECIFICATION

Operating Range (Cooling - Heating)

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) kg l/s dB(A) mm kg m m kg

V-Ph-Hz Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

A

A

RAV-CT101UH-M RAV-CT101UH-L RAV-CT151UH-M RAV-CT151UH-M

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP804ATP-E RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1104AT8-E

3

8.0

2.46

1000

3

8.0

2.52

1000

4

11.2

2.44

1500

4

11.2

2.44

1500

3.0

3.2

3.0

3.0

260 - 1050 - 780 260 - 1050 - 780 260 - 1550 - 780 260 - 1550 - 780

49

422

54

550 - 780 - 290

44

750

48 - 52

5/8” - 3/8”

5 - 50

30

20

1.7 - 40g/m

52

583

55

550 - 780 - 290

105

633

55

1340 - 900 - 320 1340 - 900 - 320

44 93

43°C to -15°C / 15°C to -15°C

750 1683

48 - 52

5/8” - 3/8”

5 - 50

30

20

1.7 - 40g/m

49 - 50

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

105

633

55

95

1683

49 - 50

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

11.43

16

230 - 1 - 50

3 core & earth

10.43

16

400 - 3 - 50

3 core & earth

3.72 per Ph

10 per Ph

£4,351

£66

£4,994

£66

£5,296

£66

£5,296

£66

£1,628

£6,045

£1,628

£6,688

£1,995

£7,357

£2,184

£7,546

Suitable for recessed installation

RBC-AMT32E £50 Retail

ampair.co.uk | 01707 378 670 | [email protected]

173

Applied Products & Air to Water

Air Curtain - Cassette Type - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight kW mm m

OUTDOOR UNIT SPECIFICATION

Operating Range (Cooling - Heating)

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) kg l/s dB(A) mm kg m m kg

V-Ph-Hz Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

A

A

RAV-CT151UH-L RAV-CT151UH-L RAV-CT201UH-M RAV-CT201UH-M

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP1104AT-E RAV-SP1104AT8-E RAV-SP1404AT-E RAV-SP1404AT8-E

4

11.2

2.65

1500

4

11.2

2.65

1500

5

14.0

2.63

2000

5

14.0

2.63

2000

3.2

3.2

3.0

3.0

260 - 1550 - 780 260 - 1550 - 780 260 - 2050 - 780 260 - 2050 - 780

107

778

107

778

111

844

111

844

56 56 56 56

1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320

93 95

1683

49 - 50

5/8” - 3/8”

3 - 75

95 93

46°C to -15°C / 15°C to -15°C

1683 1717

49 - 50

5/8” - 3/8”

3 - 75

30

51 - 52

5/8” - 3/8”

3 - 75

30

1717

51 - 52

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

30

3.1 - 40g/m

30

3.1 - 40g/m

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

10.43

16

400 - 3 - 50

3 core & earth

3.72 per Ph

10 per Ph

230 - 1 - 50

3 core & earth

15.76

25

400 - 3 - 50

3 core & earth

5.42 per Ph

16 per Ph

£5,687

£66

£5,687

£66

£6,107

£66

£6,107

£66

£1,995

£7,748

£2,184

£7,937

£2,205

£8,378

£2,279

£8,452

Suitable for recessed installation

@amp_aircon | amp-air-conditioning 174

Applied Products & Air to Water

Air Curtain - Cassette Type - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airfl ow

Sound Pressure Level

Dimensions (height - width - depth)

Weight kW mm m

OUTDOOR UNIT SPECIFICATION

Operating Range (Cooling - Heating)

Standard Airfl ow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Diff erence

Pre-charged for

Charge R410A (Factory - Additional) kg l/s dB(A) mm kg m m kg

V-Ph-Hz Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

A

A

RAV-CT201UH-L RAV-CT201UH-L RAV-CT251UH-M RAV-CT251UH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E RAV-SP1604AT8-E

5

14.0

2.82

2000

5

14.0

2.82

2000

6

16.0

3.12

2500

6

16.0

3.27

2500

3.2

3.2

3.0

3.2

260 - 2050 - 780 260 - 2050 - 780 260 - 2550 - 780 260 - 2550 - 780

113

1167

113

1167

135

1056

137

1361

57 57 57 58

1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320

93 95

1717

51 - 52

5/8” - 3/8”

3 - 75

95 95

43°C to -15°C / 15°C to -15°C

1717 1717

51 - 52

5/8” - 3/8”

3 - 75

30

51 - 53

5/8” - 3/8”

3 - 75

30

1717

51 - 53

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

30

3.1 - 40g/m

30

3.1 - 40g/m

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

15.76

25

400 - 3 - 50

3 core & earth

5.42 per Ph

16 per Ph

400 - 3 - 50

3 core & earth

6.66 per Ph

16 per Ph

400 - 3 - 50

3 core & earth

6.66 per Ph

16 per Ph

£6,887

£66

£6,887

£66

£6,891

£66

£7,626

£66

£2,205

£9,158

£2,279

£9,232

£2,426

£9,383

£2,426

£10,118

Suitable for recessed installation

RBC-AMS41E £66 Retail

ampair.co.uk | 01707 378 670 | [email protected]

175

Applied Products & Air to Water

Air Curtain - Built-In - Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating) kW mm m

OUTDOOR UNIT SPECIFICATION

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) m m kg kg l/s dB(A) mm kg

Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

V-Ph-Hz

A

A

RAV-CT101BH-M RAV-CT101BH-L RAV-CT151BH-M RAV-CT151BH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SM804ATP-E RAV-SM804ATP-E RAV-SM1104ATP-ERAV-SM1104ATP-E

3

8.0

2.46

1000

3.0

3

8.0

2.52

1000

3.2

4

11.2

2.44

1500

3.0

4

11.2

2.65

1500

3.2

405-485 - 1105 - 720 405-485 - 1105 - 720 405-485 - 1605 - 720 405-485 - 1605 - 720

77

422

54

550 - 780 - 290

44

750

48 - 52

5/8” - 3/8”

5 - 30

30

20

1.7 - 40g/m

80

583

55

550 - 780 - 290

750

48 - 52

5/8” - 3/8”

5 - 30

30

20

1.7 - 40g/m

113

633

55

890 - 900 - 320

44 68

46°C to -15°C / 15°C to -15°C

1133

53 - 54

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

115

778

56

890 - 900 - 320

68

1133

53 - 54

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

230 - 1 - 50

3 core & earth

11.43

16

£4,847

£66

230 - 1 - 50

3 core & earth

11.43

16

£4,884

£66

230 - 1 - 50

3 core & earth

15.18

20

£5,831

£66

230 - 1 - 50

3 core & earth

15.18

20

£6,099

£66

£1,177

£6,090

£1,177

£6,127

£1,549

£7,446

£1,549

£7,714

Suitable for recessed ducted installation

@amp_aircon | amp-air-conditioning 176

Applied Products & Air to Water

Air Curtain - Built-In - Digital Inverter

OUTDOOR UNIT SPECIFICATION

Air Curtain

Outdoor Unit

Retail Price

RAV-CT201BH-M RAV-CT201BH-L RAV-CT251BH-M RAV-CT251BH-L

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating)

Standard Airflow

Power Supply

Interconnecting Cables

Air Curtain

Remote Controller kW mm m kg l/s dB(A) mm kg l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max)

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional)

Maximum Running Current

Suggested Fuse Size in m m m kg

V-Ph-Hz

A

A

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SM1404ATP-ERAV-SM1404ATP-E RAV-SM1603AT-E RAV-SM1603AT-E

5

14.0

2.63

2000

5

14.0

2.82

2000

6

16.0

3.12

2500

6

16.0

3.27

2500

3.0

3.2

3.0

3.2

405-485 - 2105 - 720 405-485 - 2105 - 720 405-485 - 2605 - 720 405-485 - 2605 - 720

143

844

56

890 - 900 - 320

68

1167

54 - 55

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

230 - 1 - 50

3 core & earth

21.37

32

145

1167

57

890 - 900 - 320

185

1056

57

1340 - 900 - 320 1340 - 900 - 320

68 99

46°C to -15°C / 15°C to -15°C

1167 1717

54 - 55

5/8” - 3/8”

5 - 50

30

30

2.8 - 40g/m

230 - 1 - 50

3 core & earth

21.37

32

51 - 53

5/8” - 3/8”

5 - 50

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

21.70

32

189

1361

58

99

1717

51 - 53

5/8” - 3/8”

5 - 50

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

21.70

32

£6,357

£66

£6,967

£66

£7,196

£66

£7,863

£66

£1,633

£8,056

£1,633

£8,666

£2,059

£9,321

£2,059

£9,988

Suitable for recessed ducted installation

ampair.co.uk | 01707 378 670 | [email protected]

177

RBC-AMS54E-ES £105 Retail

Applied Products & Air to Water

Air Curtain - Built-In - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating) kW mm m

OUTDOOR UNIT SPECIFICATION

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) m m kg kg l/s dB(A) mm kg

Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

V-Ph-Hz

A

A

RAV-CT101BH-M RAV-CT101BH-L RAV-CT151BH-M RAV-CT151BH-M

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP804ATP-E RAV-SP804ATP-E RAV-SP1104AT-E RAV-SP1104AT8-E

3

8.0

2.46

1000

3.0

3

8.0

2.52

1000

3.2

4

11.2

2.44

1500

3.0

4

11.2

2.44

1500

3.0

405-485 - 1105 - 720 405-485 - 1105 - 720 405-485 - 1605 - 720 405-485 - 1605 - 720

77

422

54

550 - 780 - 290

44

750

48 - 52

5/8” - 3/8”

5 - 50

30

20

1.7 - 40g/m

80

583

55

550 - 780 - 290

44

113

633

55

1340 - 900 - 320 1340 - 900 - 320

93

43°C to -15°C / 15°C to -15°C

750

48 - 52

5/8” - 3/8”

5 - 30

30

20

1.7 - 40g/m

1683

49 - 50

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

113

633

55

95

1683

49 - 50

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

11.43

16

£4,847

£66

230 - 1 - 50

3 core & earth

11.43

16

£4,884

£66

230 - 1 - 50

3 core & earth

10.43

16

£5,831

£66

400 - 3 - 50

3 core & earth

3.72 per Ph

10 per Ph

£5,831

£66

£1,628

£6,541

£1,628

£6,578

£1,995

£7,892

£2,184

£8,081

Suitable for recessed ducted installation

@amp_aircon | amp-air-conditioning 178

Applied Products & Air to Water

Air Curtain - Built-In - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight kW mm m

OUTDOOR UNIT SPECIFICATION

Operating Range (Cooling - Heating)

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) kg l/s dB(A) mm kg m m kg

Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

V-Ph-Hz

A

A

RAV-CT151BH-L RAV-CT151BH-L RAV-CT201BH-M RAV-CT201BH-M

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP1104AT-E RAV-SP1104AT8-E RAV-SP1404AT-E RAV-SP1404AT8-E

4

11.2

2.65

1500

4

11.2

2.65

1500

5

14.0

2.63

2000

5

14.0

2.63

2000

3.2

3.2

3.0

3.0

405-485 - 1605 - 720 405-485 - 1605 - 720 405-485 - 2105 - 720 405-485 - 2105 - 720

115

778

115

778

143

844

143

844

56 56 56 56

1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320

93 95

1683

49 - 50

5/8” - 3/8”

3 - 75

95 93

46°C to -15°C / 15°C to -15°C

1683 1717

49 - 50

5/8” - 3/8”

3 - 75

30

51 - 52

5/8” - 3/8”

3 - 75

30

1717

51 - 52

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

30

3.1 - 40g/m

30

3.1 - 40g/m

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

10.43

16

400 - 3 - 50

3 core & earth

3.72 per Ph

10 per Ph

230 - 1 - 50

3 core & earth

15.76

25

400 - 3 - 50

3 core & earth

5.42 per Ph

16 per Ph

£6,099

£66

£6,099

£66

£6,357

£66

£6,357

£66

£1,995

£8,160

£2,184

£8,349

£2,205

£8,628

£2,279

£8,702

Suitable for recessed ducted installation

RBC-AS41E £70 Retail

ampair.co.uk | 01707 378 670 | [email protected]

179

Applied Products & Air to Water

Air Curtain - Built-In - Super Digital Inverter

Air Curtain

Remote Controller

Outdoor Unit

Horse Power

Heating Capacity

Heating COP

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Dimensions (height - width - depth)

Weight

Operating Range (Cooling - Heating) kW mm m

OUTDOOR UNIT SPECIFICATION

Standard Airflow l/s

Sound Pressure Level (Cooling - Heating) dB(A)

Pipe Sizes (Gas - Liquid)

Pipe Limits (min - max) in m

Maximum Height Difference

Pre-charged for

Charge R410A (Factory - Additional) m m kg kg l/s dB(A) mm kg

Power Supply

Interconnecting Cables

Maximum Running Current

Suggested Fuse Size

Air Curtain

Remote Controller

Outdoor Unit

Retail Price

V-Ph-Hz

A

A

RAV-CT201BH-L RAV-CT201BH-L RAV-CT251BH-M RAV-CT251BH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

RAV-SP1404AT-E RAV-SP1404AT8-E RAV-SP1604AT8-E RAV-SP1604AT8-E

5

14.0

2.82

2000

3.2

5

14.0

2.82

2000

3.2

6

16.0

3.12

2500

3.0

6

16.0

3.27

2500

3.2

405-485 - 2105 - 720 405-485 - 2105 - 720 405-485 - 2605 - 720 405-485 - 2605 - 720

145

1167

145

1167

185

1056

189

1361

57 57 57 58

1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320 1340 - 900 - 320

93 95 95

43°C to -15°C / 15°C to -15°C

95

1717

51 - 52

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

1717

51 - 52

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

1717

51 - 53

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

1717

51 - 53

5/8” - 3/8”

3 - 75

30

30

3.1 - 40g/m

230 - 1 - 50

3 core & earth

15.76

25

400 - 3 - 50

3 core & earth

5.42 per Ph

16 per Ph

400 - 3 - 50

3 core & earth

6.66 per Ph

16 per Ph

400 - 3 - 50

3 core & earth

6.66 per Ph

16 per Ph

£6,967

£66

£6,967

£66

£7,196

£66

£7,863

£66

£2,205

£9,238

£2,279

£9,312

£2,426

£9,688

£2,426

£10,355

Suitable for recessed ducted installation

@amp_aircon | amp-air-conditioning 180

Applied Products & Air to Water

Air Curtain - Free Hanging - VRF

Air Curtain

Remote Controller

Accessory Kit

Capacity Code

Heating Capacity

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

PIPE WORK

Gas Pipe Sizes

Liquid Pipe Sizes

Power Supply

Power Input

Suggested Fuse Size

Air Curtain

Remote Controller

Accessory Kit

Retail Price

kW mm m kg l/s dB(A) in in

V-Ph-Hz kW

A

RAV-CT101CH-M RAV-CT101CH-L RAV-CT151CH-M RAV-CT151CH-L

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

3

8.0

1000

3.0

3

8.0

1000

3.2

4

11.2

1500

3.0

4

11.2

1500

3.2

260 - 1210 - 490 260 - 1210 - 490 260 - 1710 - 490 260 - 1710 - 490

54 57 85 87

422

54

583

55

633

55

778

56

5/8”

3/8”

230 - 1 - 50

5/8”

3/8”

230 - 1 - 50

5/8”

3/8”

230 - 1 - 50

5/8”

3/8”

230 - 1 - 50

0.56

10

£4,157

0.82

10

£4,687

0.74

10

£5,253

1.11

10

£5,523

£66

£856

£5,079

£66

£856

£5,609

£66

£856

£6,175

£66

£856

£6,445

Air Curtain

Remote Controller

RAV-CT201CH-M RAV-CT201CH-L RAV-CT251CH-M RAV-CT251CH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

PIPE WORK

Accessory Kit

Capacity Code

Heating Capacity

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Gas Pipe Sizes

Liquid Pipe Sizes

Power Supply

Power Input

Suggested Fuse Size kW mm m kg l/s dB(A) in in

V-Ph-Hz kW

A

MMD-ODH1

5

14.0

MMD-ODH1

5

14.0

MMD-ODH1

6

16.0

MMD-ODH1

6

16.0

2000

3.0

2000

3.2

2500

3.0

2500

3.2

260 - 2210 - 490 260 - 2210 - 490 260 - 2710 - 490 260 - 2710 - 490

115 117 147 149

844

56

5/8”

3/8”

230 - 1 - 50

0.93

10

£6,020

1167

57

5/8”

3/8”

230 - 1 - 50

1.64

16

£6,834

1056

57

5/8”

3/8”

230 - 1 - 50

1.11

10

£6,841

1361

58

5/8”

3/8”

230 - 1 - 50

1.92

16

£7,159 Air Curtain

Remote Controller

Accessory Kit

Retail Price

£66

£856

£6,950

Suitable for installation above the door where whole unit will be visible

Ceiling mounting kit for model 100 to 200, part number 3871 retail price £50

Ceiling mounting kit for model 25, part number 4034 retail price £68

£66

£856

£7,756

£66

£856

£7,763

£66

£856

£8,081

ampair.co.uk | 01707 378 670 | [email protected]

181

Applied Products & Air to Water

Air Curtain - Cassette Type - VRF

PIPE WORK

Air Curtain

Remote Controller

Accessory Kit

Capacity Code

Heating Capacity

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Gas Pipe Sizes

Liquid Pipe Sizes

Power Supply

Power Input

Suggested Fuse Size

Air Curtain

Remote Controller

Accessory Kit

Retail Price

Air Curtain

Remote Controller

PIPE WORK

Accessory Kit

Capacity Code

Heating Capacity

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

Gas Pipe Sizes

Liquid Pipe Sizes

Power Supply

Power Input

Suggested Fuse Size

Air Curtain

Remote Controller

Accessory Kit

Retail Price

Suitable for recessed installation kW mm m kg l/s dB(A) in in

V-Ph-Hz kW

A

RAV-CT101UH-M RAV-CT101UH-L RAV-CT151UH-M RAV-CT151UH-L

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

3

8.0

1000

3.0

3

8.0

1000

3.2

4

11.2

1500

3.0

4

11.2

1500

3.2

260 - 1050 - 780 260 - 1050 - 780 260 - 1550 - 780 260 - 1550 - 780

49 52 105 107

422

54

583

55

633

55

778

56

5/8”

3/8”

230 - 1 - 50

5/8”

3/8”

230 - 1 - 50

5/8”

3/8”

230 - 1 - 50

5/8”

3/8”

230 - 1 - 50

0.56

10

£4,351

0.82

10

£4,994

0.74

10

£5,296

1.11

10

£5,687

£66

£856

£5,273

£66

£856

£5,916

£66

£856

£6,218

£66

£856

£6,609

kW mm m kg l/s dB(A) in in

V-Ph-Hz kW

A

RAV-CT201UH-M RAV-CT201UH-L RAV-CT251UH-M RAV-CT251UH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E

MMD-ODH1

5

14.0

MMD-ODH1

5

14.0

MMD-ODH1

6

16.0

MMD-ODH1

6

16.0

2000

3.0

2000

3.2

2500

3.0

2500

3.2

260 - 2050 - 780 260 - 2050 - 780 260 - 2550 - 780 260 - 2550 - 780

111 113 135 137

844

56

5/8”

3/8”

230 - 1 - 50

0.93

10

£6,107

1167

57

5/8”

3/8”

230 - 1 - 50

1.64

16

£6,887

1056

57

5/8”

3/8”

230 - 1 - 50

1.11

10

£6,891

1361

58

5/8”

3/8”

230 - 1 - 50

1.92

16

£7,626

£66

£856

£7,029

£66

£856

£7,809

£66

£856

£7,813

£66

£856

£8,548

@amp_aircon | amp-air-conditioning 182

Air Curtain

Remote Controller

Accessory Kit

Capacity Code

Heating Capacity

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

Standard Airflow

Sound Pressure Level

PIPE WORK

Gas Pipe Sizes

Liquid Pipe Sizes

Power Supply

Power Input

Suggested Fuse Size

Air Curtain

Remote Controller

Accessory Kit

Retail Price

Air Curtain

Remote Controller

Accessory Kit

Capacity Code

Heating Capacity

Door Width

Maximum Door Height

Dimensions (height - width - depth)

Weight

PIPE WORK

Standard Airflow

Sound Pressure Level

Gas Pipe Sizes

Liquid Pipe Sizes

Power Supply

Power Input

Suggested Fuse Size

Air Curtain

Remote Controller

Accessory Kit

Retail Price

Suitable for recessed ducted installation

Applied Products & Air to Water

Air Curtain - Built-In - VRF kW mm m kg l/s dB(A) in in

V-Ph-Hz kW

A

RAV-CT101BH-M RAV-CT101BH-L RAV-CT151BH-M RAV-CT151BH-L

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

RBC-AMS41E

MMD-ODH1

3

8.0

1000

3.0

3

8.0

1000

3.2

4

11.2

1500

3.0

4

11.2

1500

3.2

405-485 - 1105 - 720 405-485 - 1105 - 720 405-485 - 1605 - 720 405-485 - 1605 - 720

77 80 113 115

422

54

5/8”

3/8”

230 - 1 - 50

0.56

10

£4,847

583

55

5/8”

3/8”

230 - 1 - 50

0.82

10

£4,884

633

55

5/8”

3/8”

230 - 1 - 50

0.74

10

£5,831

778

56

5/8”

3/8”

230 - 1 - 50

1.11

10

£6,099

£66

£856

£5,769

£66

£856

£5,806

£66

£856

£6,753

£66

£856

£7,021

RAV-CT201BH-M RAV-CT201BH-L RAV-CT251BH-M RAV-CT251BH-L

RBC-AMS41E RBC-AMS41E RBC-AMS41E RBC-AMS41E kW mm m kg l/s dB(A) in in

V-Ph-Hz kW

A

MMD-ODH1

5

14.0

2000

3.0

MMD-ODH1

5

14.0

2000

3.2

MMD-ODH1

6

16.0

2500

3.0

MMD-ODH1

6

16.0

2500

3.2

405-485 - 2105 - 720 405-485 - 2105 - 720 405-485 - 2605 - 720 405-485 - 2605 - 720

143 145 185 189

844

56

5/8”

3/8”

1167

57

5/8”

3/8”

1056

57

5/8”

3/8”

1361

58

5/8”

3/8”

230 - 1 - 50

0.93

10

£6,357

230 - 1 - 50

1.64

16

£6,967

230 - 1 - 50

1.11

10

£7,196

230 - 1 - 50

1.92

16

£7,863

£66

£856

£7,279

£66

£856

£7,889

£66

£856

£8,118

£66

£856

£8,785

ampair.co.uk | 01707 378 670 | [email protected]

183

Applied Products & Air to Water

Estia Introduction

With its best in class COP performance, Estia air to water heat pump system delivers more heating power with less energy consumption. Estia uses high quality components and material which contribute to the overall savings in energy consumption. With the Toshiba advanced inverter, Estia air to water heat pump systems deliver the heating capacity required; thus consuming only the necessary electricity.

Easy to install

Quick and easy to install. The hydro module unit can be placed safely in the most suitable place within the house. The compact outdoor unit can be placed anywhere outside the house or on a balcony, thanks to extensive piping options.

Environmentally conscious

The use of Toshiba Estía heat pumps contributes to the reduction of global CO2 emissions and limits the use of fossil fuels or other non-renewable energy primary sources. Whenever required for maintenance, all the R410A refrigerant (non ozone depleting) can be completely pumped back to the outdoor unit through the powerful embedded Toshiba “pump down” operation.

One system, multiple solutions

Estía heat pump systems can be used in combination with different types of emitters: existing heating low temperature radiators, floor heating or fan coil units.

Incentives

Every country in Europe has already issued or is in the process of promoting incentive schemes for the installation of heat pump systems. Grants or tax rebates are calculated using the nominal COP as a reference, with progressively annual efficiency entering into consideration. The installation of Estía air to water heat pump systems with high nominal COP and outstandingly high partial load COP, thanks to its inverter DC Twin rotary compressor, guarantees to match most local governments requirements.

The right temperature at the right time

It can produce water at different temperatures for several applications simultaneously. Toshiba Estía air to water heat pump systems operate smoothly both with low outdoor air temperature down to -20 °C in winter and up to 43 °C in the summer season.

@amp_aircon | amp-air-conditioning 184

Applied Products & Air to Water

Estia - Outdoor Units - Standard - Single Phase

Outdoor Unit

Heating Capacity *1

Rated Water Flow (Heating Condition 1)

Input Power (Heating Condition 1)

COP (Heating Condition 1)

Operating Temp. Range Hydro/Outdoor

Operating Humid Range Hydro/Outdoor

Unit Dimensions (H-W-D)

PHYSI- CAL

Weight (Indoor - Outdoor)

Sound Pressure level - Hydro

Sound Pressure level - Outdoor

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Power Supply (Outdoor)

Hydro Unit Running Current Heating

Hydro Unit Power Input Heating

Outdoor Unit running Current Heating

Outdoor Unit Power Input Heating

Total Running Current heating

Suggested Fuse Size kW l/m kW

°C mm kg dB(A) dB(A) in m m kg

V-Ph-Hz

A kW

A

Kw

A

A

HWS-804H-E1

8.0

22.90

1.79

4.46

890 - 900 - 320

63

27

49

5/8” - 3/8”

30 - 30

30

1.8 - n/a

230 - 1 - 50

0.44

0.06

7.97

1.73

8.41

20

HWS-1104H-E1

11.2

32.10

2.30

4.88

5°C to 32°C / -20°C to 43°C

15% to 85% / 15% to 100%

1340 - 900 - 320

92

29

49

5/8” - 3/8”

30 - 30

30

2.7 - n/a

230 - 1 - 50

0.66

0.09

10.08

2.21

10.74

25

HWS-1404H-E1

14.0

40.10

3.11

4.50

1340 - 900 - 320

92

29

51

5/8” - 3/8”

30 - 30

30

2.7 - n/a

230 - 1 - 50

0.66

0.09

13.74

3.02

14.40

25

Outdoor Unit

Retail Price

£1,936

£1,936

£2,138

£2,138

£2,515

£2,515

*1 Heating performance measurement conditions: outside air temperature 7°C, water supply temperature 30°C, outlet water temperature 35°C, refrigerant piping length 7.5m (no height difference)

Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail

Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail

Wired Remote Controller for room air temperature control. HWS-AMS11E, £90 Retail

ampair.co.uk | 01707 378 670 | [email protected]

185

Applied Products & Air to Water

Estia - Outdoor Units - Standard - Three Phase

PHYSI- CAL

Outdoor Unit

Heating Capacity *1

Rated Water Flow (Heating Condition 1)

Input Power (Heating Condition 1)

COP (Heating Condition 1)

Operating Temp. Range Hydro/Outdoor

Operating Humid Range Hydro/Outdoor

Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Sound Pressure level - Hydro

Sound Pressure level - Outdoor

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Power Supply (Outdoor)

Hydro Unit Running Current Heating

Hydro Unit Power Input Heating

Outdoor Unit running Current Heating

Outdoor Unit Power Input Heating

Total Running Current heating

Suggested Fuse Size kW l/m kW

°C mm kg dB(A) dB(A) in m m kg

V-Ph-Hz

A kW

A

Kw

A

A

HWS-1104H8-E1

11.2

32.10

2.34

4.80

1340 - 900 - 320

93

29

49

5/8” - 3/8”

30 - 30

30

2.7 - n/a

400 - 3 - 50

0.66

0.09

3.73 per Ph

2.25

4.39 per Phase

16 per Phase

HWS-1404H8-E1

14.0

40.10

3.16

4.44

5°C to 32°C / -20°C to 43°C

15% to 85% / 15% to 100%

1340 - 900 - 320

93

29

51

5/8” - 3/8”

30 - 30

30

2.7 - n/a

400 - 3 - 50

0.66

0.09

5.01 per Phase

3.07

5.67 per Phase

16 per Phase

HWS-1604H8-E1

16.0

45.80

3.72

4.30

1340 - 900 - 320

93

29

52

5/8” - 3/8”

30 - 30

30

2.7 - n/a

400 - 3 - 50

0.66

0.09

5.94 per Phase

3.63

6.60 per Phase

16 per Phase

Outdoor Unit

Retail Price

£2,504

£2,504

£2,706

£2,706

£3,075

£3,075

*1 Heating performance measurement conditions: outside air temperature 7°C, water supply temperature 30°C, outlet water temperature 35°C, refrigerant piping length 7.5m (no height difference)

Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail

Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail

Wired Remote Controller for room air temperature control. HWS-AMS11E, £90 Retail

@amp_aircon | amp-air-conditioning 186

Applied Products & Air to Water

Estia - Hot Water Tanks - Standard

Domestic Hot Water Tank

Water Volume

Maximum Water Temperature

Electric Heater

Standing Heat Loss kWh/day

Nominal Storage Capacity of Units liter - kg

Liters

°C kW

Maximum Water Supply Pressure to Prv Mpa-bar

Operating Pressure of Unit

Expansion Vessel Charge Pressure

Mpa-bar

Mpa-bar

Expansion Valve Setting

Maximum Primary Working Pressure

Opening Temperature of T&P Relief

Valve

Opening Pressure of T&P Relief Valve

Mpa-bar

Mpa-bar

°C

Mpa-bar

Material

Insulation

Height

Diameter

Weight Net

Power Supply

Suggested Fuse Size

Domestic Hot Water Tank

Retail Price

mm mm kg

V-Ph-Hz

A

HWS-1501CSHM3-UK HWS-2101CSHM3-UK HWS-3001CSHM3-UK

150 210 300

75

2.75

75

2.75

75

2.75

1.45

150 - 181

1.6 - 16.0

1.91

210 - 251

1.6 - 16.0

2.52

300 - 360

1.6 - 16.0

0.35 - 3.5

0.35 - 3.5

0.6 - 6.0

0.3 - 3.0

90

1.0 - 10

0.35 - 3.5

0.35 - 3.5

0.6 - 6.0

0.3 - 3.0

90

1.0 - 10

0.35 - 3.5

0.35 - 3.5

0.6 - 6.0

0.3 - 3.0

90

1.0 - 10

1090

550

31

230 - 1 - 50

16

£987

£987

Stainless Steel

CFC/HCFC free polyurethane foam

1474

550

41

230 - 1 - 50

16

£1,151

£1,151

2040

550

60

230 - 1 - 50

16

£1,352

£1,352

ampair.co.uk | 01707 378 670 | [email protected]

187

Applied Products & Air to Water

Estia - Hydro Units - Standard

Hydro Unit

Remote Controller

Water Piping Maximum Length

Water Piping Max. Height Difference

Water Piping Minimum Flow Rate

Water Piping Max. Working Water Pres.

Heat Exchanger

Heat Exchanger Type

Heat Exchanger Water Volume

Heat Exchanger Minimum Flow Rate

Circulating Pump Max Motor Output

Circulating Pump Flow Rate

Circulating Pump Type

Water Pump Power Input

Water Pump Delivery Head m l/m

Kpa liters l/m

W l/m

W m

HWS-804XWHM3-E1

HWS-AMS11E

None

7

HWS-804XWHT6-E1

HWS-AMS11E

None

7

13+

300

17+

300

Brazed Plate

Plate-type Heat Exchanger

Brazed Plate

0.67

13

125

0.67

13

190

22.9

Non-Self suction centrifugal Pump

32.1

48

6.3

48

6.3

Unit Dimensions (H-W-D)

Weight

Pipe Sizes (Gas - Liquid)

Sound Pressure level

Expansion Vessel Volume

Expansion Vessel Initial Pressure

Water Temperature Range Heating

Back up Heater Power Supply

Back up Heater Power - Max Current mm kg in dB(A)

Liters

Mpa-Bar

Pressure Relief Valve Operating Pressure Mpa-Bar

°C

V-Ph-Hz

A

Hot Water Cylinder Heater power Supply V-Ph-Hz

925 - 525 - 355

50

5/8” - 3/8”

27

12

0.1 - 1.0

0.3 - 3.0

20 - 55

230 - 1 - 50

3.0 - 13

230 - 1 - 50

925 - 525 - 355

50

5/8” - 3/8”

27

12

0.1 - 1.0

0.3 - 3.0

20 - 55

400 - 3 - 50

6.0 - 13 (13Ax2P)

230 - 1 - 50

Hot Water Cylinder Heater Max. Current A

Hydro Unit

Remote Controller

Retail Price

System Retail Prices (Excluding domestic hot water tank)

Combined with HWS-804H-E1 Outdoor Unit

12.0

£2,878

£90

£2,968

£4,904

12.0

£2,990

£90

£3,080

£5,016

Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £55 retail

Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £79 Retail

@amp_aircon | amp-air-conditioning 188

Applied Products & Air to Water

Estia - Hydro Units - Standard

Hydro Unit

Remote Controller

Water Piping Maximum Length

Water Piping Max. Height Difference

Water Piping Minimum Flow Rate

Water Piping Max. Working Water Pres.

Heat Exchanger

Heat Exchanger Type

Heat Exchanger Water Volume

Heat Exchanger Minimum Flow Rate

Circulating Pump Max Motor Output

Circulating Pump Flow Rate

Circulating Pump Type

Water Pump Power Input

Water Pump Delivery Head

Unit Dimensions (H-W-D)

Weight

Pipe Sizes (Gas - Liquid)

Sound Pressure level

Expansion Vessel Volume

Expansion Vessel Initial Pressure

Pressure Relief Valve Operating Pressure Mpa-Bar

Water Temperature Range Heating

Back up Heater Power Supply

Back up Heater Power - Max Current

Hot Water Cylinder Heater power Supply V-Ph-Hz

Hot Water Cylinder Heater Max. Current m l/m

Kpa liters l/m

W l/m

W m mm kg in dB(A)

Liters

Mpa-Bar

°C

V-Ph-Hz

A

A

Hydro Unit

Remote Controller

Retail Price

System Retail Prices (Excluding domestic hot water tank)

Combined with HWS-1104H-E1 Outdoor Unit

Combined with HWS-1404H-E1 Outdoor Unit

Combined with HWS-1104H8-E1 Outdoor Unit

Combined with HWS-1404H8-E1 Outdoor Unit

Combined with HWS-1604H8-E1 Outdoor Unit

HWS-1404XWHM3-E1 HWS-1404XWHT6-E1 HWS-1404XWHT9-E1

HWS-AMS11E HWS-AMS11E HWS-AMS11E

None

7

None

7

None

7

17+

300

17+

300

Plate-type Heat Exchanger

Brazed Plate Brazed Plate

1.18

17.5

1.18

17.5

190 190

32.1

87

8.8

925 - 525 - 355

54

40.1

Non-Self suction centrifugal Pump

87

8.8

925 - 525 - 355

54

17+

300

Brazed Plate

1.18

17.5

190

45.8

87

8.8

925 - 525 - 355

54

5/8” - 3/8”

29

12

0.1 - 1.0

0.3 - 3.0

20 - 55

230 - 1 - 50

3.0 - 13

230 - 1 - 50

12.0

£3,669

£90

£3,759

5/8” - 3/8”

29

12

0.1 - 1.0

0.3 - 3.0

20 - 55

400 - 3 - 50

6.0 - 13 (13Ax2P)

230 - 1 - 50

12.0

£3,782

£90

£3,872

5/8” - 3/8”

29

12

0.1 - 1.0

0.3 - 3.0

20 - 55

400 - 3 - 50

9.0 - 13 (13Ax3P)

230 - 1 - 50

12.0

£3,801

£90

£3,891

£5,897

£6,274

£6,263

£6,465

£6,834

£6,010

£6,387

£6,376

£6,578

£6,947

£6,029

£6,406

£6,395

£6,597

£6,966

Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail

Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail

ampair.co.uk | 01707 378 670 | [email protected]

189

Applied Products & Air to Water

Estia - Outdoor Units - High Temperature - Single Phase

PHYSI- CAL

Outdoor Unit

Heating Capacity *1

Rated Water Flow (Heating Condition 1)

Input Power (Heating Condition 1)

COP (Heating Condition 1)

Operating Temp. Range Hydro/Outdoor

Operating Humid Range Hydro/Outdoor

Unit Dimensions (H-W-D)

Weight (Indoor - Outdoor)

Sound Pressure level - Hydro

Sound Pressure level - Outdoor

Pipe Sizes (Gas - Liquid)

Pipe Limits (Max Run - Height Diff.)

Pre-charged for

Charge R410A (Factory - Additional)

Power Supply (Outdoor)

Hydro Unit Running Current Heating

Hydro Unit Power Input Heating kW l/m kW

°C mm kg dB(A) dB(A) in m m kg

V-Ph-Hz

A kW

HWS-P804HR-E1

8.0

22.90

1.68

4.76

HWS-P1104HR-E1

11.2

32.10

2.30

4.88

5°C to 32°C / -20°C to 43°C

15% to 85% / 15% to 100%

1340 - 900 - 320

92

1340 - 900 - 320

92

27

49

5/8” - 3/8”

30 - 30

30

2.7 - n/a

230 - 1 - 50

0.44

0.06

29

49

5/8” - 3/8”

30 - 30

30

2.7 - n/a

230 - 1 - 50

0.66

0.09

Outdoor Unit running Current Heating

Outdoor Unit Power Input Heating

Total Running Current heating

Suggested Fuse Size

A

Kw

A

A

7.57

1.62

8.01

25

10.33

2.21

10.99

25

Outdoor Unit

Retail Price

£2,517

£2,517

£2,557

£2,557

*1 Heating performance measurement conditions: outside air temperature 7°C, water supply temperature 30°C, outlet water temperature 35°C, refrigerant piping length 7.5m (no height difference)

Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail

Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail

Wired Remote Controller for room air temperature control. HWS-AMS11E, £90 Retail

@amp_aircon | amp-air-conditioning 190

Applied Products & Air to Water

Estia - Hot Water Tanks - High Temperature

Domestic Hot Water Tank

Water Volume

Maximum Water Temperature

Electric Heater

Standing Heat Loss kWh/day

Nominal Storage Capacity of Units liter - kg

Liters

°C kW

Maximum Water Supply Pressure to Prv Mpa-bar

Operating Pressure of Unit

Expansion Vessel Charge Pressure

Mpa-bar

Mpa-bar

Expansion Valve Setting

Maximum Primary Working Pressure

Opening Temperature of T&P Relief

Valve

Opening Pressure of T&P Relief Valve

Mpa-bar

Mpa-bar

°C

Mpa-bar

Material

Insulation

Height

Diameter

Weight Net

Power Supply

Suggested Fuse Size

Domestic Hot Water Tank

Retail Price

mm mm kg

V-Ph-Hz

A

HWS-1501CSHM3-UK HWS-2101CSHM3-UK HWS-3001CSHM3-UK

150 210 300

75

2.75

75

2.75

75

2.75

1.45

150 - 181

1.6 - 16.0

1.91

210 - 251

1.6 - 16.0

2.52

300 - 360

1.6 - 16.0

0.35 - 3.5

0.35 - 3.5

0.6 - 6.0

0.3 - 3.0

90

1.0 - 10

0.35 - 3.5

0.35 - 3.5

0.6 - 6.0

0.3 - 3.0

90

1.0 - 10

0.35 - 3.5

0.35 - 3.5

0.6 - 6.0

0.3 - 3.0

90

1.0 - 10

1090

550

31

230 - 1 - 50

16

£987

£987

Stainless Steel

CFC/HCFC free polyurethane foam

1474

550

41

230 - 1 - 50

16

£1,151

£1,151

2040

550

60

230 - 1 - 50

16

£1,352

£1,352

ampair.co.uk | 01707 378 670 | [email protected]

191

Applied Products & Air to Water

Estia - Hydro Units - High Temperature

Hydro Unit

Remote Controller

Water Piping Maximum Length

Water Piping Max. Height Difference

Water Piping Minimum Flow Rate

Water Piping Max. Working Water Pres.

Heat Exchanger

Heat Exchanger Type

Heat Exchanger Water Volume

Heat Exchanger Minimum Flow Rate

Circulating Pump Max Motor Output

Circulating Pump Flow Rate

Circulating Pump Type

Water Pump Power Input

Water Pump Delivery Head

Unit Dimensions (H-W-D)

Weight

Pipe Sizes (Gas - Liquid)

Sound Pressure level

Expansion Vessel Volume

Expansion Vessel Initial Pressure

Pressure Relief Valve Operating Pressure Mpa-Bar

Water Temperature Range Heating

Back up Heater Power Supply

Back up Heater Power - Max Current

Hot Water Cylinder Heater power Supply V-Ph-Hz

Hot Water Cylinder Heater Max. Current

Hydro Unit

Remote Controller

Retail Price

m l/m

Kpa liters l/m

W l/m

W m mm kg in dB(A)

Liters

Mpa-Bar

°C

V-Ph-Hz

A

A

HWS-P804XWHM3-E1 HWS-P804XWHT6-E1 HWS-P804XWHT6-E1

HWS-AMS11E HWS-AMS11E HWS-AMS11E

None

7

None

7

None

7

13+

300

13+

300

Plate-type Heat Exchanger

Brazed Plate Brazed Plate

0.67

13

0.67

13

125 125

22.9

48

6.3

925 - 525 - 355

49

22.9

Non-Self suction centrifugal Pump

48

6.3

925 - 525 - 355

49

13+

300

Brazed Plate

0.67

13

125

22.9

48

6.3

925 - 525 - 355

49

5/8” - 3/8”

27

12

0.1 - 1.0

0.3 - 3.0

20 - 60

230 - 1 - 50

3.0 - 13

230 - 1 - 50

5/8” - 3/8”

27

12

0.1 - 1.0

0.3 - 3.0

20 - 60

400 - 3 - 50

6.0 - 13 (13Ax2P)

230 - 1 - 50

5/8” - 3/8”

27

12

0.1 - 1.0

0.3 - 3.0

20 - 60

400 - 3 - 50

9.0 - 13 (13Ax3P)

230 - 1 - 50

12.0

£2,791

£90

12.0

£2,899

£90

12.0

£2,998

£90

£2,881 £2,989 £3,088

Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail

Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail

@amp_aircon | amp-air-conditioning 192

Applied Products & Air to Water

Estia - Hydro Units - High Temperature

Hydro Unit

Remote Controller

Water Piping Maximum Length

Water Piping Max. Height Difference

Water Piping Minimum Flow Rate

Water Piping Max. Working Water Pres.

Heat Exchanger

Heat Exchanger Type

Heat Exchanger Water Volume

Heat Exchanger Minimum Flow Rate

Circulating Pump Max Motor Output

Circulating Pump Flow Rate

Circulating Pump Type

Water Pump Power Input

Water Pump Delivery Head

Unit Dimensions (H-W-D)

Weight

Pipe Sizes (Gas - Liquid)

Sound Pressure level

Expansion Vessel Volume

Expansion Vessel Initial Pressure

Pressure Relief Valve Operating Pressure Mpa-Bar

Water Temperature Range Heating

Back up Heater Power Supply

Back up Heater Power - Max Current

Hot Water Cylinder Heater power Supply V-Ph-Hz

Hot Water Cylinder Heater Max. Current

Hydro Unit

Remote Controller

Retail Price

m l/m

Kpa liters l/m

W l/m

W m mm kg in dB(A)

Liters

Mpa-Bar

°C

V-Ph-Hz

A

A

HWS-1104XWHM3-E1 HWS-1104XWHT6-E1 HWS-1104XWHT9-E1

HWS-AMS11E HWS-AMS11E HWS-AMS11E

None

7

None

7

None

7

17.5+

300

17.5+

300

Plate-type Heat Exchanger

Brazed Plate Brazed Plate

1.18

17.5

1.18

17.5

190 190

32.1

87

8.8

925 - 525 - 355

52

32.1

Non-Self suction centrifugal Pump

87

8.8

925 - 525 - 355

52

17.5+

300

Brazed Plate

1.18

17.5

190

32.1

87

8.8

925 - 525 - 355

52

5/8” - 3/8”

29

12

0.1 - 1.0

0.3 - 3.0

20 - 60

230 - 1 - 50

3.0 - 13

230 - 1 - 50

5/8” - 3/8”

29

12

0.1 - 1.0

0.3 - 3.0

20 - 60

400 - 3 - 50

6.0 - 13 (13Ax2P)

230 - 1 - 50

5/8” - 3/8”

29

12

0.1 - 1.0

0.3 - 3.0

20 - 60

400 - 3 - 50

9.0 - 13 (13Ax3P)

230 - 1 - 50

12.0

£3,557

£90

12.0

£3,667

£90

12.0

£3,686

£90

£3,647 £3,757 £3,776

Input signal PCB - room thermostat input, emergency stop input, TCB-PCM03E, £58 retail

Output Signal PCB - boiler operation, alarm, defrost & compressor outputs, TCB-PCIN3E £83 Retail

ampair.co.uk | 01707 378 670 | [email protected]

193

“Having worked with AMP since their formation in 1989 it goes without saying that they are by far my preferred supplier.

They continue to deliver the very best service, support and expertise, my first choice for all my air conditioning needs”

Richard Morley, External Technical Support at AMP

Controls & Accessories

Controls & Accessories

Wired & Wireless Remote Controllers

Wired Remote Controllers

RBC-AMT32E

Standard Remote

Controller

Full control including service functions

£50

RBC-AMS54E-ES

Lite-Vision Plus Remote

Controller

Includes timer and back light display as well as power save functions, multi-lingual

£105

Wireless Remote Controllers

RBC-AX32U(W)-E

Wireless Remote

Controller Kit - 4 Way

Cassette

Replacement corner panel with built in receiver and remote controller for RAV and VRF standard cassettes

£151

RBC-AX33CE

Wireless Remote

Controller Kit - Ceiling

Suspended (7 Series)

Infra red kit for RAV and VRF ceiling suspended units

£166

RBC-AMS41E

Remote Controller With Built

In 7 Day Time Clock

Standard controller but with fully programmable 7 day timer

£66

RBC-AS41E

Simplifi ed Controller

Ideal for hotel and base use applications (no service function available)

£70

RBC-AX32UW(W)-E

Wireless Remote

Controller Kit - 2 Way

Cassette

Infra red remote controller kit for

VRF 2 way cassettes

£179

TCB-AX32E2

Wireless Remote

Controller Kit - Others

Infra red remote controller kit for RAV and VRF ducted, fl oor standing models and compact cassettes

£214

@amp_aircon | amp-air-conditioning 196

Controls & Accessories

Centralised Remote Controllers

Standard Centralised Controllers

TCB-CC163TLE2

On - Off Controller

Up to 16 indoor units can be turned on/off individually or collectively. run & fault output

£741

TCB-EXS21TLE

Schedule Remote Controller

Connects to TCB-SC642TLE or compliant manager to provides weekly time clock (7 day 3 on / off per day)

£271

Touch Screen Centralised Controller

TCB-SC642TLE2

Central Remote Controller

A fully programmable central controller for up to 64 indoor units

£776

Built in Web Browser

Back-up and Restore

Multi-language preference

Alarm Settings

Unit setup, status and inhibit

Programmable time and date events

Max 64 Indoor Units/Groups and 16 Outdoor systems can be connected

TCB-PCNT30TLE2 Network adaptor required for connection of DI/SDI to provide TCC Link Connection

RBC-TBPTS

Smart Touch Controller

Touch screen controller for up to

64 indoor units, including built in web browser

£2,258

ampair.co.uk | 01707 378 670 | [email protected]

197

Controls & Accessories

Centralised Remote Controllers - PC Based

Compliant / Smart Mangers

• Control up to 128 indoor units on 2 separate communication lines (64 indoors & 16 outdoors per network)

• Can be connected to all Toshiba DI, SDI and VRF indoor units (split systems require TCB-PCNT-30TLE2 interface pcb, adapter built into KRT wall mounts)

• Control via pc (web access) (BMS-SM1280ETLE only) and ability to provide energy monitoring; this will require indoor units to be manually addressed and amp will need to attend site to commission

• If time clock is required amp must attend site to enable this feature

BMS-CM1280TLE

Compliant Manager

Standard Version

BMS-SM1280ETLE

Smart Manager with Data

Analyser

Enables full control of up to

128 indoor units (2 x 64 control circuits) for control of up to 128 indoors, inc remote access via web browser

£854 £2,000

Central controller with PC connection - by connecting a PC via the LAN port of the Smart Manager, VRF & RAV* indoor units can be controlled via internet explorer

Item Description Retail

Price

Between 1 to 64 indoor units

Qty.

Req.

Total

Retail

Between 65 to 128 indoors units

Qty.

Req.

Total

Retail

Between 129 to 192 indoor units

Qty.

Req.

Total

Retail

BMS-SM1280E-

TLE

Smart manager, 128 indoor units, 64 max. per circuit

AMP-ECX crossed Ethernet cable for

PC connection

Total solution retail price

£2,000

£10

1

1

£2,000

£10

1

1

£2,000

£10

£2,010 £2,010

optional items

*TCB-PCNT30TLE

Interface PCB required by each RAV split system connected to above controls system

2

2

£4,000

£20

£4,020

Between 193 to 256 indoor units

Qty.

Req.

Total

Retail

2

2

£4,000

£20

£4,020

£78

Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE

£650

COMM2

BMS-IFDD03E

BMS-IFWH5E

Digital input / output interface to allow control & monitoring of other plant, 8 digital inputs & 4 digital outputs

Energy monitoring relay interface, allows up to 8 power meters to be connected, see RBC-EM1-PE below

£921

£440

RBC-EM1-PE

EM1-PANEL

Power meter, 1 required per refrigeration systems, see BMS-IFWH5E above and EM1-PANEL below

Housing and wiring for RBC-EM1-PE, 1 required per refrigeration system

£1,149

NETT PRICE

£1,208

Notes: • Smart manager time clock schedule set via pc on commissioning • for installations with more than 256 indoor units please contact AMP for pricing • indoor units connected to the same outdoor unit can not be connected to 2 different circuits, as such this may reduce the maximum capacity

@amp_aircon | amp-air-conditioning 198

Controls & Accessories

Centralised Remote Controllers - PC Based

Windows Control Package - Interactive Intelligence

PC based windows control package - allows Toshiba VRF & RAV* indoor units to be controlled and monitored via an on site PC

(field supplied)

Item Description Retail

Price

Between 1 to

64 indoor units

Qty.

Req.

Total

Retail

Between 65 to 128 indoor units

Qty.

Req.

Total

Retail

Between 129 to 192 indoor units

Qty.

Req.

Total

Retail

Between 193 to 256 indoor units

Qty.

Req.

Total

Retail

RBC-WP1-PE windows control package, max. 1024 indoors

£2,100 1 £2,100 1 £2,100 1 £2,100 1 £2,100

TCB-IFLN642TLE

LON gateway, maximum 64 indoor units

Total solution retail price

£1,100 1 £1,100

£3,200

2 £2,200

£4,300

optional items

*TCB-PCNT30TLE

Interface PCB required by each RAV split system connected to above controls system

3 £3,300

£5,400

4 £4,400

£6,500

£78

COMM2

Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE

£650

Internet kit to allow on site PC to be controlled via a remote location, 1 required per RBC-WP1-PE

£1,687

RBC-IK1-PE

RBC-DI1-PE

RBC-EM1-PE

EM1-PANEL

Digital input / output module to allow control of other plant via RBC-WP1-PE, 8 digital inputs & 8 digital outputs

£349

Power meter for calculating the running costs of individual indoor units, 1 required per refrigeration systems, see EM1-PANEL below

Housing and wiring for RBC-EM1-PE, 1 required per refrigeration system

£1,149

NETT PRICE

£1,208

Notes: Please contact amp for PC specification • for installations with more than 256 indoor units please contact AMP for pricing • indoor units connected to the same outdoor unit can not be connected to 2 different circuits / LON interfaces, as such this may reduce the maximum capacity of each circuit / LON interface

LONworks Gateway

Allows Toshiba VRF & RAV* indoor units to be controlled and monitored by LONworks BMS

Item Description Retail

Price

Between 1 to 64 indoor units

Qty.

Req.

Total

Retail

Between 65 to 128 indoor units

Qty.

Req.

Total

Retail

Between 129 to 192 indoor units

Qty.

Req.

Total

Retail

TCB-IFLN642TLE

LON gateway, maximum 64 indoor units

Total solution retail price

optional items

£1,100 1 £1,100

£1,100

2 £2,200

£2,200

*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system

3 £3,300

£3,300

Between 193 to 256 indoor units

Qty.

Req.

Total

Retail

4 £4,400

£4,400

£78

COMM2

Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE

£650

ampair.co.uk | 01707 378 670 | [email protected]

199

Controls & Accessories

BMS Interfaces

Modbus Blackpear BMS Interfaces

Modbus Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored via Modbus RTU via RS232 / RS485 and

Modbus / TCP

Item Description Retail

Price

Between 1 to 64 indoor units

Qty.

Req

Total

Retail

Between 65 to 128 indoor units

Qty.

Req

Total

Retail

Between 129 to 192 indoor units

Qty.

Req

Total

Retail

RBC-BPM1

Modbus Interface - 64 indoor units max

Total solution retail price

£3,513 1 £3,513

£3,513

2 £7,026

£7,026

optional items

*TCB-PCNT30TLE

Interface PCB required by each RAV split system connected to above controls system

3 £10,539

£10,539

Between 193 to 256 indoor units

Qty.

Req

Total

Retail

4 £14,052

£14,052

£78

COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE

£650

Trend Blackpear BMS Interfaces

Trend Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored via Trend via ethernet (also requires IQ3/4 outstation with spare memory, by others

Item Description Retail

Price

Between 1 to 64 indoor units

Qty.

Req

Total

Retail

Between 65 to 128 indoor units

Qty.

Req

Total

Retail

Between 129 to 192 indoor units

Qty.

Req

Total

Retail

RBC-BPT1

Trend Interface - 64 indoor units max

Total solution retail price

£3,513 1 £3,513

£3,513

2 £7,026

£7,026

optional items

*TCB-PCNT30TLE

Interface PCB required by each RAV split system connected to above controls system

3 £10,539

£10,539

Between 193 to 256 indoor units

Qty.

Req

Total

Retail

4 £14,052

£14,052

£78

COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE

£650

BACnet Blackpear BMS Interfaces

BACnet Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored via BACnet / IP

Item Description Retail

Price

Between 1 to 64 indoor units

Qty.

Req

Total

Retail

Between 65 to 128 indoor units

Qty.

Req

Total

Retail

Between 129 to 192 indoor units

Qty.

Req

Total

Retail

RBC-BPB1

Modbus Interface - 64 indoor units max

Total solution retail price

£3,313 1 £3,513

£3,513

2 £7,026

£7,026

optional items

*TCB-PCNT30TLE Interface PCB required by each RAV split system connected to above controls system

3 £10,539

£10,539

Between 193 to 256 indoor units

Qty.

Req

Total

Retail

4 £14,052

£14,052

£78

COMM2

Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE

£650

@amp_aircon | amp-air-conditioning 200

Controls & Accessories

BMS Interfaces

BACnet Gateway

BACnet Interface - Allows Toshiba VRF & RAV* indoor units to be controlled & monitored by BACnet over IP based BMS

Item Description Retail

Price

Between 1 to 64 indoor units

Qty.

Req.

Total

Retail

Between 65 to 128 indoor units

Qty.

Req.

Total

Retail

Between 129 to 192 indoor units

Qty.

Req.

Total

Retail

BMS-LSV9E

BMS-STBN10E intelligent server for up to

128 indoor unit max.

intelligent server software (1 per intelligent server)

£3,597

£1,739

1

1

£3,597

£1,739

1

1

£3,597

£1,739

2

2

£7,194

£3,478

BMS-IFLSV4E

TCS-Net relay interface

Total solution retail price

£672 1 £672

£6,008

2 £1,344

£6,680

optional items

*TCB-PCNT30TLE

Interface PCB required by each RAV split system connected to above controls system

3 £2,016

£12,688

Between 193 to 256 indoor units

Qty.

Req.

Total

Retail

2

2

4

£7,194

£3,478

£2,688

£13,360

£78

COMM2 Controls commissioning assistance service, 1 day per 64 indoor units recommended NETT PRICE

£650

Intesis Home Interfaces

RBC-TO-RC-WIFI-1

INTESIS Home Interface

Suitable for RAV and VRF Units.

For compatibility list visit intesishome.com/compatibility

£271

RBC-IS-IR-WIFI-1

Infrared WiFi Adapter

For compatibility list visit intesishome.com/compatibility

£208

ampair.co.uk | 01707 378 670 | [email protected]

201

Black Pear Interface

Controls & Accessories

Indoor Wiring Adapters

Remote Sensor

TCB-TC41LE

Remote Sensor

Remote return air sensor

£64

Indoor Unit Wiring Adapters

Part Number

RBC-SMFI

AMP-TCH

RBC-SMIM2

RBC-SMT1

AMP-TRF

AMP-TRFVF

AMP-TRFVF+

RBC-SMCN61

Function

Fan output

Operation output

Operation output

Plug

CN32

CN60

CN60

Remote on / off

On remote

Operation input / output

(12VDC output), see following page for details

Operation input / output

(volt free output)

Operation input / output

(volt free output and 12VDC on/off)

CN61

Interface lead for on / off & unit remote controller lock

Description

Provides control of auxiliary ventilation fan through local remote

Operation status output for cooling, heating, fan, defrost and thermo on, 12V DC

Operation status output for cooling, heating, fan, volt free

An external input on RBC-

AMT32-E remote controller for remote on / off, volt free

A range of interface for on/ off, lock and run / fault, see details of each interface for functionality

RBC-SMIM3

Indicator for lock out fault and unit run, volt free

TCB-IFCB-4E

Remote location on / off control box

AMP-L30I Outside error input CN80

Input to generate L30 stopping fault code, stop system and brings up fault code

RAV

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

VRF

Yes

Retail Price

£54

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

£16

£82

£9

£16

£68

£110

£11

£76

£229

TBC

@amp_aircon | amp-air-conditioning 202

Controls & Accessories

Outdoor Wiring Adapters

AMP-TRF

Outdoor Unit Wiring Adapters

Part Number Function

TCB-PCDM4E

Plug Description

Power peak cut control

CN513

Restricts the upper limit capacity of the outdoor unit, reducing peak energy usage

RAV

No

TCB-PCM04E

Snow fall fan control

No

VRF

Retail Price

Yes

£81

Yes

£63

TCB-PCM04E

External master on/off

TCB-PCM04E

Night operation

No

TCB-PC1N4E

Error operation output

CN511

/

CN513

(mini)

Run and fault output (when more than 1 indoor unit has a fault)

No

No

Yes

Yes

Yes

£63

£89

£63

TCB-PCM04E

Operation mode selection

CN510

Input to outdoor unit to either force

(8HP+) or set priority (4-6HP) to either cooling or heating

TCB-PCOS1E2

TCB-KBOS1E

Night operation

Night operation

No Yes

£63

CN300

/

CN704

& 610

Input to outdoor unit to reduce sound level, also reduce max. system capacity

(DI 2 and 3 series, SDI 404 & 564)

CN300

CN704

CN610

Input to outdoor unit to reduce sound level, also reduce max. system capacity (DI & SDI 4 series, not 404 or 564 models)

Yes*

Yes*

No

No

£149

£27

*RAV DI, some of series 3 only, SDI some of series 4 only

ampair.co.uk | 01707 378 670 | [email protected]

203

Controls & Accessories

Leak Detection & Containment

Toshiba has a solution to help you gain BREEAM credits and more.

In-line with the building services industries continued pro-active eff orts to reduce CO2 emissions and to meet targets to build greener buildings, Toshiba have developed a market leading Leak Detection and

Pump-down system that enables BREEAM credits to be claimed on a building using both Split DX and VRF systems. In addition, our solution also provides a means to demonstrate compliance with the current

EN378 2008 standard where refrigerant concentration levels may exceed practical safety limits of 0.44kg/ m3.

Leak Detection Set-Up

The leak detection system works via sensors which detect changes in the refrigerant pressure which signifi es a decrease in the levels of refrigerant gas. This triggers and audible and visual alarm and shuts down the device. In the case of the RBC-RD6 unit, the outdoor unit, a cooling mode will be enabled and pump-down will commence.

All leak detection options can be used on Digital Inverter, Super Digital Inverter, Large Capacity Digital

Inverter, MiNi SMMS, SMMSe and SHRMi Units.

Where DI, SDI and LCDI units are selected the contractor will need to insert a Schader access port into the common suction line, before this can be carried out the refrigerant from the outdoor unit would need to be removed. This on site modifi cation is required to enable the pump-down solutions to work with these units.

@amp_aircon | amp-air-conditioning 204

Controls & Accessories

Leak Detection & Containment

Toshiba offer a range of sophisticated refrigerant monitoring, leak detection and containment systems. Below is a brief overview of the available items, please contact Amp for complete system configuration and pricing.

RBC-RD3 RBC-RD6 RBC-RD7

System Pump Down Interface Unit Isolation Leak Detection Room Sensor

The recessed room sensor is triggered if the concentration of

R410A refrigerant exceeds the practical safety limit of 0.44kg / m3 as stated in BSEN378 2012. The sensor raises an audible and visual alarm within the bedroom and also via an

L30 fault alarm this can transmit an indication alarm at the Toshiba WP1 software control loaded onto the reception office PC.

£444

The RBC-RD6 enables both a major or gradual refrigerant leak to be identified and the activation of a system pump - down to be triggered.

The solution includes all isolation valves and central control panel.

£5,992

In conjunction with the RBC-RD3 room sensor, via the RBC-RD7

Toshiba are able to provide a means to isolate an individual bedroom or occupied space without the need to fully shut down the air conditioning system.

TBC

RBC-RP1

Repeater Panel Complete With

Battery Back Up

RBC-RI1

Room Indicator (legrand

Graphite)

RBC-AIP1

Remote Indication Alarm - For up to 8 x RBC-RD6 / RBC-RP1 panels inc. RBC-DI1

The RBC-RP1 repeater panel is designed to work in conjunction with the Toshiba RBC-RD6 pump down panel.

Room indicator offers a visual and audible alarm if a leak is detected and has an integrated button to deactivate. for use with RBC-RP1

Toshiba provide a means of identifying that there has been a leak on the system in the event of the PC being turned off. This panel enables a remote alarm to be raised in the event of the RD6 pump-down being activated

£1,437

RBC-AIP2

Remote Indication Alarm and

Remote reset - For up to 4 x

RBC-RD6 panels inc. RBC-DI

Toshiba provide a means of identifying that there has been a leak on the system in the event of the PC being turned off. This panel enables a remote alarm to be raised in the event of the RD6 pump-down being activated

£2,727

£80

RBC-AIP3

Alarm Indication

If the PC running the RBC-WP1 software and monitoring RBC-RD3’s should shut down or lose power. The

RBC-AIP3, located within 3m of the desktop PC can monitor all potential failures and is fully USB compliant with a battery backup system.

TBC

£1,663

RBC-AIP4

Remote Alarm Indication

Remote alarm indication is provided by the RBC-AIP4 that can be up to

100m away from the main panel.

This means an alarm can be remotely indicated in the largest buildings.

TBC

ampair.co.uk | 01707 378 670 | [email protected]

205

Controls & Accessories

Brackets, Trays, Cages & Other Accessories

CBR2-S

Small Outdoor

Unit Bracket

Max load - 60KG

£23

CBR2-M

Medium Outdoor

Unit Bracket

Max load - 90KG

Crossbar - 900mm

Upright - 500mm

Support arm - 500mm

£32

CBR2-L

Large Outdoor

Unit Bracket

Max load - 140KG

Crossbar - 1100mm

Upright - 550mm

Support arm - 540mm

£36

CBR1-XL

Extra Large

Outdoor

Unit Bracket

Max load - 250KG

Crossbar - n/a

Upright - 550mm

Support arm - 700mm

£55

CCTM-800

Small Heavy Duty

Metal Drain Tray

CCTM-1100

Large Heavy Duty

Metal Drain Tray

L800 X W400mm

£53

L1100 X W400mm

£58

CCTM-1400

Large Heavy Duty

Metal Drain Tray

L1400 X W400mm

£64

CG-BPS

Base Panel For High

Level Cage

Installation

CG-BPM

Base Panel For High

Level Cage

Installation

For CG-S

£41

For CG-M, CG-L and

CG-XL

£45

CG-S

Small

Condenser Cage

External dimensions:

H750 X W1050 X

D460mm

Internal dimensions:

H720 X W1020 X

D450mm

Weight: 18kg

£189

CG-M

Medium

Condenser Cage

External dimensions:

H1150 X W1150 X

D650mm

Internal dimensions:

H1120 X W1120 X

D640mm

Weight: 30kg

£272

CG-L

Large

Condenser Cage

External dimensions:

H1450 X W1150 X

D650mm

Internal dimensions:

H1420 X W1120 X

D640mm

Weight: 33kg

£328

CG-XL

Extra Large

Condenser Cage

External dimensions:

H1800 X W1150 X

D650mm

Internal dimensions:

H1770 X W1120 X

D640mm

Weight: 44kg

£468

CMB-450

450mm Outdoor

Unit Mounting

Block

CMB-1000

1000mm Outdoor

Unit Mounting

Block

Price Per Unit

£4

Price Per Unit

£9

MBEC

End Caps

Price Per Unit

£2

Net Prices.

@amp_aircon | amp-air-conditioning 206

Toshiba Rewards

Toshiba Rewards

Introduction

Installer Network

Toshiba recognises the contribution that its network of installers makes towards our continued success story. In-line with their vision statement they have created a rewards incentive programme that further enhances the benefits available to our loyal customers.

Toshiba installers can continue to exchange loyalty points accumulated for purchasing Toshiba air conditioning products and redeem them for LOVE2SHOP gift cards, Toshiba air conditioning products or trade installation tools (see pages 210 - 211).

As an additional bonus they now offer a joint marketing initiative, as well as the clothing allowance for all members.

Qualifying Conditions

»

To qualify for the rewards incentive all members must register with Toshiba Carrier UK Limited or with AMP Air Conditioning Limited.

»

Only one account holder per company can register as a member.

»

Points are accumulated on paid invoices of Toshiba air conditioning equipment.

»

Sales channels through Toshiba Direct, Toshiba Distributor, Toshiba Wholesaler or Toshiba Approved

Re-seller (please refer to Toshiba web site for supplier details)

»

No minimum turnover.

»

Customer must adhere to F-Gas regulations and be Refcom registered (or equivalent) and be fully compliant (copy of current Certificate required)

»

Please speak to your sales person who will be happy to assist with your registration details.

Every £40 net of invoiced purchases equates to 1 point

Exchange rewards points for…

»

Love2Shop gift card

»

European and Worldwide holidays with Love2Travel

»

Toshiba air conditioning units and accessories

»

Trade installation products

»

Marketing support

@amp_aircon | amp-air-conditioning 208

Toshiba Rewards

Warranty

Rewards Enhanced Warranty

In addition to earning rewards points, by simply registering and being accepted onto the scheme you will automatically be entitled to an enhanced 5 year warranty on all future purchase of Toshiba equipment.

This can be further enhanced by attending Toshiba training courses, as detailed below.

T5 Registered Installer

»

Refcom – F-gas qualifi cation

»

5 Years warranty

»

No minimum spend

»

Generous warranty labour allowances

T7 Approved Partner

»

Refcom – F-gas qualifi cation

»

Completed the following Toshiba training courses

»

Digital Inverter / Super Digital Inverter

»

VRF

»

Controls

»

7 Years warranty

»

No minimum spend

»

Generous warranty labour allowances

T7 Enhanced Warranty Partner

»

Refcom – Fgas qualifi cation

»

Completed the following Toshiba training courses

»

Digital Inverter / Super Digital Inverter

»

VRF

»

Controls

»

7 Years warranty

»

No minimum spend

»

Enhanced warranty labour allowances

»

Website processing for commissioning data and maintenance records

ampair.co.uk | 01707 378 670 | [email protected]

209

Toshiba Rewards

Rewards Gift Cards

Exchange rewards points for Love2Shop gift cards

The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for Love2Shop gift cards including European and

Worldwide holidays with Love2Travel:

Exchange Love2Shop gift card for other Love2Shop promotions:

»

Love2Shop Mobile

New purchase of mobile phones, tablets and SIM cards using Love2Shop Gift Cards visit www.l2s-mobile.co.uk

»

Digital gift codes exchange online for goods or vouchers:

Amazon, B&Q, Starbucks, iTunes, Debenhams, John Lewis and many more

»

Love2Shop Holidays

Spend your gift card on a holiday including package holidays, UK breaks, theme parks, flights, cruises, hotels with airport parking or simply spend your gift card on a holiday call 0845 077 4444

»

Love2Shop Experiences

Accepted at a fantastic range of attractions, including Alton Towers Resort and Gulliver’s World Theme Parks

Can be used at www.love2shopexperiences.co.uk to book hundreds of unique experiences.

Activities available include relaxing spa

Redemption Values for Love2Shop

Value

£100

£150

£200

£250

£300

£350

£400

£450

£500

£550

Points

200

290

380

470

560

650

740

830

920

1,000

@amp_aircon | amp-air-conditioning 210

Toshiba Rewards

Toshiba Units & Installation Tools

Exchange rewards points for Toshiba air conditioning equipment and accessories

The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for more air conditioning units and accessories. Redemption value is equal to net price.

Illustrative example of redemption value at net price.

RAV-SM566KRT-E

»

Retail Price

»

Contractor discount 42%

»

Net Price

»

Points required

RAV-SM564ATP-E

»

Retail Price

»

Contractor discount 42%

»

Net Price

»

Points required

£391.00

£164.41

£226.59

227

£840.00

£352.80

£487.20

488

Exchange rewards points for air conditioning trade installation tools

The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for installation tools listed below:

Item

Promax RG5410 Extreme Recovery unit 110V

Mastercool 99661-EU Digital Manifold 2-Way

Hydraulic Crossbow Tube Bender 3/8 - 7/8 tube

PRO100 new Style Tube Expander Set (up to 1 1/8)

BM4-3-DS-R410A-SRW Manifold Kit

Xp-1 Electronic Leak Detector

ACCU Charge Electronic Scale 98200-A

Clarke TL-2 3.85M Telescopic Ladder

CT808F Eccentric Flaring Tool (1/4" - 3/4")

Points Required

1170

744

670

338

273

448

193

222

58

ampair.co.uk | 01707 378 670 | [email protected]

211

Toshiba Rewards

Marketing Contribution & Project Support

Rewards Marketing Contribution

The points accumulated for paid purchases of Toshiba air conditioning units and air conditioning accessories can be exchanged for marketing support.

»

Trade Clothing

»

Sign writing of vehicles

»

Corporate Days

»

Industry Dinners

»

Sponsorship

»

Sports Events

»

Marketing support tools

Toshiba will provide a 50 / 50 contribution towards marketing

»

Illustrative example Golf day accumulated value £1,000 + TCUK £1,000 = £2,000

»

Limited to a maximum of 1% of member’s annual purchase value

»

Subject to approval by Toshiba Carrier UK Limited.

»

Marketing claim(s) must be approved in advance by Toshiba Carrier UK Limited and conform to

United Technologies Corporation guidelines and agreements (available on request)

Retrospective Adjustment Credit (RAC) for Registered Specifications

A Registered Member on successfully achieving a consultant’s full specification for Toshiba equipment on a specified project may register that project with the Toshiba Projects Department to obtain and allocate a

Toshiba Quote Number (TQN). Proof of the consultant’s full specification document must subsequently be submitted either by hard copy or electronic form naming the specifying Registered Member. In the event that more than one Registered Member claims to have specified the project, the project will be registered to the Registered Member supplying the earliest dated tender document naming the Registered Member as the Registered Installer.

In the event that the specifying Registered Member’s tender bid is unsuccessful, providing that the successful contractor purchases Toshiba equipment for the specified project registered on the TQN from Toshiba either direct or through our registered

Toshiba Distributor, Toshiba Wholesaler or Toshiba Approved

Re-seller, Toshiba agrees to award the Registered Member who successfully registered the project with a Retrospective

Adjustment Credit (RAC) to the value of 3% of the retail price of the actual equipment supplied for the specified project as published in the latest Retail Price List.

For full terms and conditions please contact AMP

@amp_aircon | amp-air-conditioning 212

Toshiba Rewards

Application

Rewards Incentive Application Form (illustration)

For further information and to apply please contact

AMP Air Conditioning

ampair.co.uk | 01707 378 670 | [email protected]

213

“AMP are one of our top suppliers; they are always very helpful and flexible with excellent back up and support. Overall they provide an excellent service.”

Liam Stay - Integra

Photo: Zuzzana Reed, Finance Manager at AMP

Reference / Faults Codes

Reference

RAV Fault Codes

Fault codes are displayed directly on wired remote controller – to access the service history: press

CHECK and SET for 4 seconds

» press CHECK and SET for 4 seconds

» scroll through stored codes using the TEMP set buttons

» press CHECK to cancel service history

» press CLEAR to delete codes

» up to 4 Codes can be stored

Code

E01

E02

Description

Controller (local or network) receives no communication from a master indoor unit- could include that master is turned off. Also check that there is a master controller

Local controller failure (unable to transmit)

E03

E04

E08

E09

Master indoor unit receives no data to A-B. Often appears as an E01 fault code

Indoor unit (except twin slave) receives no communication from outdoor unit; can include klixon on 560

Digital Inverter split system

Duplicated indoor address

2 local controller on a group – both configured as masters

E10

E18

F01

F02

Indoor PCB failure

Communication failure between master indoor unit and slave

Indoor TCJ sensor error

Indoor TC2 sensor error

F04

F06

F08

TD1 sensor error

TE1 sensor error

TO sensor error

F10

F29

H01

H02

H03

Indoor TA sensor error

Indoor PCB failure

Inverter compressor over current detected

Master outdoor unit over current detected shortly after start up

Current detected on master outdoor unit whilst idle

Reference

RAV Fault Codes

P07

P10

P12

L31

P01

P03

P04

L08

L09

L29

L30

Code

H06

L03

L07

Description

Low pressure detected by Ps sensor (0.02Mpa)

Duplicated master indoor units in a group

Indoor in a group previously addressed as a single unit – check addressing

Indoor address not set

Indoor unit capacity not set

IPDU error (number of detected IPDU units is reduced)

Input on CN80 circuit for 1 minute

Outdoor PCB error

Indoor fan motor error

High discharge temperature (TD1 exceeded 115°C)

High pressure switch activated (Detected by high TE temp on Digital Inverter)

Heat sink overheat

Float switch activated

Indoor fan motor error – detected by feedback circuit

P19

P22

P26

P29

Wrong change in temperature (4 way valve error)

Outdoor fan IPDU error

Giant Transistor short circuit comp or inverter error

Compressor error detected by feedback circuit

P31

Indoor PCB error

Error by TCC-Link central controller

Code Description

C05

C06

C12

P30

Sending error in TCC-Link central control device

Receiving error in TCC-Link central control device

Batch alarm for general purpose equipment control interface

Group control follower unit error/duplicated central control addresses

Reference

VRF Fault Codes

Remote

E01

E02

E03

E04

E06

---

E08

E09

E10

---

---

---

Outdoor 7 segment display Check code

Communication error between indoor unit and remote controller (Detected at remote controller)

---

---

---

E06

No. of indoor units in which sensor has been normally received

E07 ---

E08 Duplicated indoor address

Sending error of remote controller

Communication error between indoor unit and remote controller (Detected indoor)

Communication circuit error between indoor and outdoor units (Detected indoor)

Decrease of No. of indoor units

Communication circuit error of indoor and outdoor units

(Detected outdoor)

Duplicated indoor address

---

---

---

---

Duplicated master remote controllers communication error in indoor PCB

E12

E15

E12

01: Indoor / Outdoor communication

02: communication between outdoor units

E15 ---

Automatic address start error

No indoor automatic address

00: Over capacity

E16

E16 No. of indoor units / Over capacity

01: No. of connected units

E18

-----

Communication error between indoor header and follow units

00: No. header units

E19

E19 Outdoor header units quantity error

02: 2 or more header units

E20

E23

E25

E26

E28

E31

E20

01: Outdoor of other line connected

02: indoor of other line connected

E23 ---

E25 ---

E26

No. of outdoor units which receive signal normally

E28 Detected outdoor unit number

E31

01: IPDU 1 error

02: IPDU 2 error

03: IPDU 1, 2 error

04: Fan IPDU error

05: IPDU 1 + Fan IPDU error

06: IPDU 2 + Fan IPDU error

07: All IPDU error

Other line connected during automatic address

Sending error in communication between outdoor units

Duplicated follower outdoor unit addresses

Decrease of No. of connected outdoor units

Outdoor follower error

IPDU communication error

Device remote controller remote controller

Indoor

Indoor

I/F

I/F

Indoor / I/F remote controller

Indoor

I/F

I/F

I/F

Indoor

I/F

I/F

I/F

I/F

I/F

I/F

I/F

Reference

VRF Fault Codes

F15

F16

F23

F24

F29

F31

Remote

F01

F02

F03

F04

F05

F06

F07

F08

F10

F12

---

---

---

F04 ---

F05 ---

F06 ---

F07 ---

F08 ---

---

---

---

---

F12 ---

Outdoor 7 segment display Check code

--indoor TCJ (coil) sensor error indoor TC2 (coil) sensor error indoor TC1 (coil) sensor error outdoor TD1 (discharge) sensor error outdoor TD2 (discharge) sensor error outdoor TE1 () sensor error outdoor TL () sensor error outdoor T0 (ambient) sensor error

Indoor TA (Return Air) sensor error

Outdoor TS1 (Suction) sensor error

F13

F13

01: Compressor 1 side

02: Compressor 2 side

Outdoor TH (IPDU) sensor error

F15 ---

F16 ---

F23 ---

F24 ---

-----

F31 ---

Outdoor temp. sensors misconnected (TE, TL)

Outdoor pressure sensors misconnected (pd, Ps)

Outdoor Ps (pressure) sensor error

Outdoor Pd (pressure) sensor error

Indoor other error

Outdoor EPROM error

H01

01: Compressor 1 side

H01

02: Compressor 2 side

Compressor breakdown

H02

H03

H04

H06

H07

H02

01: Compressor 1 side

02: Compressor 2 side

H03

01: Compressor 1 side

02: Compressor 2 side

H04 ---

H06 ---

H07 ---

Magnetic switch (contactor) error Over current relay operation Compressor error (Lock)

Current detection circuit system error

Compressor 1 case thermo operation

Low pressure protection operation

Low oil level protection detected

IPDU

I/F

I/F

I/F

I/F

Indoor

I/F

IPDU

MG-SW over current relay IPDU

IPDU

I/F

I/F

I/F

Device

Indoor

Indoor

Indoor

I/F

I/F

I/F

I/F

I/F

Indoor

I/F

Reference

VRF Fault Codes

L06

L07

L08

L09

L03

L04

L05

L10

L17

L18

L20

L28

Remote

H08

H14

H16

L29

Outdoor 7 segment display Check code

01: TK1 sensor error

02: TK2 sensor error

H08

03: TK3 sensor error

04: TK4 sensor error

H14 ---

01: TK1 oil circuit system error

H16

02: TK2 oil circuit system error

03: TK3 oil circuit system error

04: TK4 oil circuit system error

L03 ---

L04 ---

L05 ---

L06 No. of indoor units with priority

-----

L08 ---

-----

L10 ---

L17 ---

L18 ---

-----

L28 ---

01: IPDU1 error

02: IPDU2 error

03: IPDU3 error

L29 04: Fan IPDU error

05: IPDU1 + Fan IPDU error

06: IPDU2 + Fan IPDU error

07: All IPDU error

Oil level detection temperature sensor error

Compressor 2 case thermo operation

Oil level detection circuit error, Magnetic switch (contactor) error, Over current relay operation

Duplicated indoor header units

Duplicated outdoor line address

Duplicated indoor units with priority (Displayed on indoor unit with priority)

Duplicated indoor units with priority (Displayed in unit other than indoor unit with priority)

Group line in individual indoor unit

Indoor group / address unset

Indoor capacity unset

Outdoor capacity unset

Inconsistency error of outdoor units

FS unit error

Duplicated central controller addresses

No. of connected outdoor units overcapacity

No. of IPDU error

Device

I/F

I/F

MG-SW over current relay

I/F

Indoor

I/F

I/F

I/F

Indoor

Indoor

Indoor

I/F

I/F

FS unit

AI-NET

I/F

Reference

VRF Fault Codes

Remote

L30

---

P01

P03

Outdoor 7 segment display Check code

L30 Detected indoor address Auxiliary interlock in indoor unit

L31 ---

-----

P03 ---

IC error

Indoor fan motor error

Discharge temperature TD1 error

P04

01: Compressor 1 side

P04

02; Compressor 2 side

High pressure switch detection error

P05

P07

P10

P12

P13

P15

P17

P19

P20

P22

P26

P29

P31

P05

01: Phase-missing detection

02: Phase order error

P07

01: Compressor 1 side

02: Compressor 2 side

P10 Detected indoor address

-----

P13 ---

01: TS condition

P15

02: TD condition

P17 ---

P19 Detected outdoor unit number

P20 ---

0_:IGBT short

1_: Fan motor position circuit error

P22

3_: Fan motor error

C_; TH sensor temp. error (overheat)

D_: TH sensor error

E_: Vdc output error

01: Compressor 1 side

P26

02: Compressor 2 side

P29

01: Compressor 1 side

02: Compressor 2 side

-----

Phase-missing detection / Phase order error

Heat sink overheat error

Indoor overflow error

Indoor fan motor error

Outdoor liquid back detection error

Gas leak detection

Discharge temperature TD2 error

4-Way valve inverse error

High pressure protection operation

Alt Outdoor fan IPDU error

G-TR short circuit protection error

Compressor position detective circuit system error

Other indoor unit error (Group follower unit error)

Device

Indoor

I/F

Indoor

I/F

IPDU

I/F

IPDU I/F

Indoor

Indoor

I/F

I/F

I/F

I/F

I/F fan IPDU

IPDU

IPDU

Indoor

Reference

Replacement Technology Tables

Reuse of Existing Pipework - RAV Split Systems

Use the tables on this page to determine if it is possible to reuse existing pipework for a given outdoor unit. The maximum pipe run, pre-charged length and any reduction in cooling capacity will depend on the pipe sizes used.

Outdoor Unit Sizes 40* - 56*

Outdoor Unit Sizes 80* - 160*

Outdoor Unit Sizes 224* - 280*

Reference

Conditions & Conversions

Nominal and UK conditions

Nominal capacities (kW) specified in this price book are calculated under ISO-T1 (JIS) standard conditions as follows:

Cooling

Indoor temperature 27ºCDB, 19ºCWB

Outdoor temperature 35ºCDB

Heating

Indoor temperature 20ºCDB

Outdoor temperature 7ºCDB, 6ºCWB

UK cooling capacities (kW) specified in this price book are calculated under the following conditions:

Indoor temperature 23ºCDB, 16º CWB

Outdoor temperature 30ºCDB

UK heating capacities (kW) specified in this price guide are calculated under the following conditions:

Indoor temperature: 22ºCDB

Outdoor temperature: -4ºCWB, -3ºCDB

Electrical

Information relating to local power supplies are shown for guidance only and must be subject to IEE regulations as well as site requirements. All three phase supplies to be TPNE.

Energy labeling

All ENER - Lot 10 information is available at www.ecodesign.toshiba-airconditioning.eu/en

Pipe size

» 1/4in = 6.35mm

» 3/8in = 9.52mm

» 1/2in = 12.70mm

» 5/8in = 15.88mm

» 3/4in = 19.05mm

» 7/8in = 22.22mm

» 11/8in = 28.58mm

» 13/8in = 34.93mm

Conversion data

» kW x 3412 = btu/h

» ºC x 1.8 + 32 = ºF

» l/s x 3.6 = m

3

/h

» bar x 14.51 = psi

» m

2

x 10.76 = ft

2

Information included in this price book is for guidance only and does not form part of a contract.

Reference

Index | RAS & RAV Systems

Section

RAS Residential

Indoor Unit

Introduction & Range Overview

Daiseikai 6 Wall Mounted

Daiseikai 8 Wall Mounted

Bi Flow Floor Standing

RAS-07BKV-E

Mirai Wall Mounted - R410A

RAS-10BKV-E

RAS-13BKV-E

RAS-16BKV-E

Mirai Wall Mounted - R32

RAS-05BKVG-E

RAS-07BKVG-E

RAS-10BKVG-E

RAS-13BKVG-E

AvAnt Wall Mounted

RAS-16BKVG-E

RAS-107SKV-E7

RAS-137SKV-E7

RAS-167SKV-E7

RAS-13G2KVP-E

RAS-16G2KVP-E

RAS-B10UFV-E1

RAS-B13UFV-E1

RAS-B18UFV-E1

Outdoor Unit

RAS-07BAV-E

RAS-10BAV-E

RAS-13BAV-E

RAS-16BAV-E

RAS-05BAVG-E

RAS-07BAVG-E

RAS-10BAVG-E

RAS-13BAVG-E

RAS-16BAVG-E

RAS-107SAV-E6

RAS-137SAV-E6

RAS-167SAV-E5

RAS-B10N3KVP-E RAS-10N3AVP-E

RAS-B13N3KVP-E RAS-13N3AVP-E

RAS-B16N3KVP-E RAS-16N3AVP-E

RAS-10G2KVP-E RAS-10G2AVP-E

RAS-13G2AVP-E

RAS-16G2AVP-E

RAS-10N3AV2-E1

RAS-13N3AV2-E1

RAS-18N3AV2-E

RAS-2M14S3AV-E

RAS-2M18S3AV-E

RAS-3M18S3AV-E

Multi Split Outdoor Units

RAS-3M26S3AV-E

RAS-4M27S3AV-E

RAS-5M34S3AV-E

Multi Split Indoors RAS-B10N3KVP-E

14

14

13

14

12

13

12

12

11

11

10

10

Page

No

7

8

19

20

19

19

18

18

17

18

17

17

16

16

15

16

15

15

Section

Multi Split Indoors

Combination Tables

Indoor Unit

RAS-B13N3KVP-E

RAS-B16N3KVP-E

Outdoor Unit

RAS-B10N3KV2-E1

RAS-B13N3KV2-E1

RAS-B16N3KV2-E1

RAS-B10UFV-E1

RAS-B13UFV-E1

RAS-B18UFV-E1

RAS-M10SMUV-E

RAS-M13SMUV-E

RAS-M16SMUV-E

RAS-M07G3DV-E

RAS-M10G3DV-E

RAS-M13G3DV-E

RAS-M16G3DV-E

22

22

21

22

22

23

21

21

21

21

20

21

20

20

Page

No

20

20

RAV Split Systems

RAV Systems Range Overview

RAV-SM307KRTP-E RAV-SM304ATP-E

Wall Mounted Digital

Inverter

RAV-SM407KRTP-E RAV-SM404ATP-E

RAV-SM566KRT-E RAV-SM564ATP-E

RAV-SM806KRT-E RAV-SM804ATP-E

RAV-SM407KRTP-E RAV-SP404ATP-E

Wall Mounted Super Digital

Inverter

RAV-SM566KRT-E

RAV-SM806KRT-E

RAV-SP564ATP-E

RAV-SP804ATP-E

RAV-SM304MUT-E RAV-SM304ATP-E

Compact Cassettes Digital

Inverter

RAV-SM404MUT-E RAV-SM404ATP-E

RAV-SM564MUT-E RAV-SM564ATP-E

Compact Cassettes Super

Digital Inverter

RAV-SM404MUT-E RAV-SP404ATP-E

41

41

39

39

41

42

38

39

37

38

33

35

37

Reference

Index | RAV Systems

Section

Compact Cassettes Super

Digital Inverter

Indoor Unit Outdoor Unit

RAV-SM564MUT-E RAV-SP564ATP-E

RAV-SM564UTP-E RAV-SM564ATP-E

Page

No

42

44

4 Way Cassettes Digital

Inverter

RAV-SM804UTP-E RAV-SM804ATP-E

RAV-SM1104UTP-E RAV-SM1104ATP-E

RAV-SM1404UTP-E RAV-SM1404ATP-E

RAV-SM1604UTP-E RAV-SM1603AT-E

RAV-SM564UTP-E RAV-SP564ATP-E

4 Way Cassettes Super

Digital Inverter Single Phase

RAV-SM804UTP-E RAV-SP804ATP-E

RAV-SM1104UTP-E RAV-SP1104AT-E

RAV-SM1404UTP-E RAV-SP1404AT-E

47

47

46

46

45

45

44

44

RAV-SM1104UTP-E RAV-SP1104AT8-E

4 Way Cassettes Super

Digital Inverter Three Phase

RAV-SM1404UTP-E RAV-SP1404AT8-E

RAV-SM1604UTP-E RAV-SP1604AT8-E

RAV-SM304SDT-E RAV-SM304ATP-E

Slim Ducted Digital Inverter RAV-SM404SDT-E

RAV-SM564SDT-E

RAV-SM404ATP-E

RAV-SM564ATP-E

Slim Ducted Super Digital

Inverter

RAV-SM404SDT-E

RAV-SM564SDT-E

RAV-SP404ATP-E

RAV-SP564ATP-E

RAV-SM406BTP-E

RAV-SM566BTP-E

RAV-SM404ATP-E

RAV-SM564ATP-E

Standard Ducted Digital

Inverter

RAV-SM806BTP-E RAV-SM804ATP-E

RAV-SM1106BTP-E RAV-SM1104ATP-E

RAV-SM1406BTP-E RAV-SM1404ATP-E

RAV-SM1606BTP-E RAV-SM1603AT-E

RAV-SM406BTP-E RAV-SP404ATP-E

RAV-SM566BTP-E RAV-SP564ATP-E

Standard Ducted Super

Digital Inverter Single Phase

RAV-SM806BTP-E RAV-SP804ATP-E

RAV-SM1106BTP-E RAV-SP1104AT-E

RAV-SM1406BTP-E RAV-SP1404AT-E

Standard Ducted Super

Digital Inverter Three Phase RAV-SM1106BTP-E RAV-SP1104AT8-E

55

55

54

54

53

54

53

53

56

57

55

56

51

51

50

50

48

50

48

48

Section Indoor Unit

Standard Ducted Super

Digital Inverter Three

Phase

RAV-SM1406BTP-E

RAV-SM1606BTP-E

High Static Ducted

Digital Inverter

RAV-SM2242DT-E

RAV-SM2802DT-E

RAV-SM407CTP-E

RAV-SM567CTP-E

Ceiling Suspended

Digital Inverter

Ceiling Suspended

Super Digital Inverter

Single Phase

RAV-SM807CTP-E

RAV-SM1107CTP-E

RAV-SM1407CTP-E

RAV-SM1607CTP-E

RAV-SM407CTP-E

RAV-SM567CTP-E

RAV-SM807CTP-E

RAV-SM1107CTP-E

Outdoor Unit

RAV-SP1404AT8-E

RAV-SP1604AT8-E

RAV-SM2244AT8-E

RAV-SM2804AT8-E

RAV-SM404ATP-E

RAV-SM564ATP-E

RAV-SM804ATP-E

RAV-SM1104ATP-E

Page

No

57

57

RAV-SM1404ATP-E

RAV-SM1603AT-E

62

62

RAV-SP404ATP-E

RAV-SP564ATP-E

RAV-SP804ATP-E

RAV-SP1104AT-E

63

64

63

63

Ceiling Suspended

Super Digital Inverter

Three Phase

RAV-SM1407CTP-E

RAV-SM1107CTP-E

RAV-SM1407CTP-E

RAV-SM1607CTP-E

Floor Standing VRF

Indoor Unit Conversions

RAV-SP1404AT-E

RAV-SP1104AT8-E

RAV-SP1404AT8-E

RAV-SP1604AT8-E

AMP-MML-AP0154BH-E RAV-SM564ATP-E

AMP-MML-AP0184BH-E RAV-SM564ATP-E

AMP-MML-AP0244BH-E RAV-SM804ATP-E

AMP-MML-AP0154H-E RAV-SM564ATP-E

AMP-MML-AP0184H-E RAV-SM564ATP-E

AMP-MML-AP0244H-E RAV-SM804ATP-E

AMP-MMF-AP0156H-E RAV-SM564ATP-E

AMP-MMF-AP0246H-E RAV-SM804ATP-E

AMP-MMF-AP0276H-E RAV-SM804ATP-E

AMP-MMF-AP0366H-E RAV-SM1104ATP-E

AMP-MMF-AP0486H-E RAV-SM1404ATP-E

AMP-MMF-AP0566H-E RAV-SM1603AT-E

67

67

67

67

67

66

66

67

66

66

66

66

65

65

64

65

61

62

61

61

59

59

Reference

Index | RAV & VRF Systems

Section

Floor Standing

VRF Indoor Unit

Conversions

Indoor Unit Outdoor Unit

AMP-MMF-AP0156H-E RAV-SP564ATP-E

AMP-MMF-AP0246H-E RAV-SP804ATP-E

AMP-MMF-AP0276H-E RAV-SP804ATP-E

AMP-MMF-AP0366H-E RAV-SP1104AT-E

AMP-MMF-AP0486H-E RAV-SP1404AT-E

AMP-MMF-AP0566H-E RAV-SP1604AT8-E

Digital Inverter Twin Split Systems

Super Digital Inverter Twin Split Systems

Digital Inverter Triple Split Systems

Super Digital Inverter Triple Split Systems

Digital Inverter & Super Digital Inverter Quad Split Systems

68

68

68

68

Page

No

68

68

74

76

70

72

78

Section

SMMSe Heat Pump

Outdoor Units

Indoor Unit

VRF Systems

VRF Outdoor Range Overview

Mini SMMS Heat

Pump Outdoor Units

SMMSe Heat Pump

Outdoor Units

MCY-MAP0401HT

MCY-MAP0501HT

MCY-MAP0601HT

MMY-MAP0806HT8P-E

84

85

84

84

81

83

MMY-MAP1006HT8P-E 85

MMY-MAP1206HT8P-E 85

MMY-MAP1406HT8P-E 86

MMY-MAP1606HT8P-E 86

MMY-MAP1806HT8P-E 86

MMY-MAP2006HT8P-E 87

MMY-AP2206HT8P-E

MMY-AP2416HT8P-E

MMY-AP2616HT8P-E

MMY-AP2816HT8P-E

MMY-AP3016HT8P-E

MMY-AP3216HT8P-E

89

89

88

88

87

88

SHRMi Heat

Recovery Outdoor

Units

99

100

100

98

98

97

98

99

97

97

96

96

95

96

95

95

94

94

93

93

92

93

92

92

91

91

90

90

Page

No

89

90

MMY-MAP0804FT8-E

MMY-MAP1004FT8-E

MMY-MAP1204FT8-E

MMY-MAP1404FT8-E

MMY-AP1614FT8-E

MMY-AP1814FT8-E

MMY-AP2014FT8-E

MMY-AP2214FT8-E

MMY-AP2414FT8-E

MMY-AP2614FT8-E

MMY-AP2814FT8-E

MMY-AP3014FT8-E

MMY-AP3214FT8-E

MMY-AP3414FT8-E

MMY-AP3614FT8-E

MMY-AP3814FT8-E

Outdoor Unit

MMY-AP3416HT8P-E

MMY-AP3616HT8P-E

MMY-AP3816HT8P-E

MMY-AP4016HT8P-E

MMY-AP4216HT8P-E

MMY-AP4416HT8P-E

MMY-AP4616HT8P-E

MMY-AP4816HT8P-E

MMY-AP5016HT8P-E

MMY-AP5216HT8P-E

MMY-AP5416HT8P-E

MMY-AP5616HT8P-E

MMY-AP5816HT8P-E

MMY-AP6016HT8P-E

Reference

Index | VRF Systems

Section

SHRMi Heat

Recovery Outdoor

Units

Indoor Unit

VRF Indoor

Flow Selector Units & Branch Pipes

VRF Indoor - Range Overview

UK Cooling Capacities

UK Heating Capacities

1 Way Cassette

MMU-AP0074YH1-E

MMU-AP0094YH1-E

MMU-AP0124YH1-E

MMU-AP0154SH1-E

MMU-AP0184SH1-E

MMU-AP0244SH1-E

MMU-AP0056MH1-E

MMU-AP0074MH1-E

4 Way Compact

Cassette

4 Way Cassette

MMU-AP0094MH1-E

MMU-AP0124MH1-E

MMU-AP0154MH1-E

MMU-AP0184MH1-E

MMU-AP0094HP1-E

MMU-AP0124HP1-E

MMU-AP0154HP1-E

MMU-AP0184HP1-E

MMU-AP0244HP1-E

MMU-AP0274HP1-E

MMU-AP0304HP1-E

MMU-AP0364HP1-E

MMU-AP0484HP1-E

MMU-AP0564HP1-E

110

111

111

112

112

109

109

110

110

112

113

113

108

108

108

109

106

107

107

107

104

105

106

106

102

102

103

Outdoor Unit

MMY-AP4014FT8-E

MMY-AP4214FT8-E

Page

No

101

101

Section

2 Way Cassette

Standard Ducted

Slim Ducted

MMU-AP0562WH1-E

MMD-AP0076BHP1-E

MMD-AP0096BHP1-E

MMD-AP0126BHP1-E

MMD-AP0156BHP1-E

MMD-AP0186BHP1-E

MMD-AP0246BHP1-E

MMD-AP0276BHP1-E

MMD-AP0306BHP1-E

MMD-AP0366BHP1-E

MMD-AP0486BHP1-E

MMD-AP0566BHP1-E

MMD-AP0056SPH1-E

MMD-AP0074SPH1-E

MMD-AP0094SPH1-E

MMD-AP0124SPH1-E

MMD-AP0154SPH1-E

MMD-AP0184SPH1-E

MMD-AP0244SPH1-E

MMD-AP0274SPH1-E

Indoor Unit

MMU-AP0072WH1-E

MMU-AP0092WH1-E

Outdoor Unit

MMU-AP0122WH1-E

MMU-AP0152WH1-E

MMU-AP0182WH1-E

MMU-AP0242WH1-E

MMU-AP0272WH1-E

MMU-AP0302WH1-E

MMU-AP0362WH1-E

MMU-AP0482WH1-E

124

124

125

125

122

122

123

123

120

121

121

121

119

119

120

120

117

118

118

118

116

116

116

117

114

115

115

115

Page

No

114

114

Section Indoor Unit

MMD-AP0186HP1-E

MMD-AP0246HP1-E

High Static Ducted

MMD-AP0276HP1-E

MMD-AP0366HP1-E

MMD-AP0486HP1-E

MMD-AP0566HP1-E

MMD-AP0726HP1-E

MMD-AP0966HP1-E

MMD-AP0364H-EU

High Static Ducted -

High Flow

MMD-AP0484H-EU

MMD-AP0564H-EU

MMK-AP0073H1

Wall Mounted 3

Series

Wall Mounted 4

Series

MMK-AP0093H1

MMK-AP0123H1

MMK-AP0153H1

MMK-AP0183H1

MMK-AP0243H1

MMK-AP0054MHP-E1

MMK-AP0074MHP-E1

MMK-AP0094MHP-E1

Floor Mounted

Cabinet

MMK-AP0124MHP-E1

MMC-AP0157HP1-E

MMC-AP0187HP1-E

MMC-AP0247HP1-E

Ceiling Suspended MMC-AP0277HP1-E

MMC-AP0367HP1-E

MMC-AP0487HP1-E

MMC-AP0567HP1-E

MMF-AP0156H1-E

MMF-AP0186H1-E

Outdoor Unit

Reference

Index | VRF Systems, Air Handling & HRV

136

136

137

137

134

135

135

136

132

133

133

134

131

131

131

132

129

130

130

130

128

128

129

129

126

127

127

127

Page

No

126

126

Section

Floor Mounted

Cabinet

Floor Standing

Chassis

Floor Standing

Console

Floor Standing Bi

Flow Console

Indoor Unit

MMF-AP0246H1-E

MMF-AP0276H1-E

MMF-AP0366H1-E

MMF-AP0486H1-E

MMF-AP0566H1-E

MML-AP0074BH1-E

MML-AP0094BH1-E

MML-AP0124BH1-E

MML-AP0154BH1-E

MML-AP0184BH1-E

MML-AP0244BH1-E

MML-AP0074H1-E

MML-AP0094H1-E

MML-AP0124H1-E

MML-AP0154H1-E

MML-AP0184H1-E

MML-AP0244H1-E

MML-AP0074NH1-E

MML-AP0094NH1-E

MML-AP0124NH1-E

MML-AP0154NH1-E

MML-AP0184NH1-E

Outdoor Unit

Air Handling & HRV

Air to Air Heat

Exchangers with

DX Coil

MMD-VN502HEX1E

MMD-VN802HEX1E

MMD-VN1002HEX1E

MMD-VNK502HEX1E

Air to Air Heat

Exchangers with DX

Coil & Humidifier

MMD-VNK802HEX1E

MMD-VNK1002HEX1E

141

142

142

142

140

140

141

141

139

139

139

140

Page

No

138

138

144

144

145

145

143

143

143

144

148

149

149

149

147

148

148

Section

Fresh Air Intake

Units

Heat Recovery

Ventilation Units

VRF Air Handling

Unit Interface

VN-M500HE

VN-M650HE

VN-M800HE

VN-M1000HE

VN-M1500HE

VN-M2000HE

MM-DXC010

MM-DXC010

Indoor Unit

MMD-AP0481HFE

MMD-AP0721HFE

MMD-AP0961HFE

VN-M150HE

VN-M250HE

VN-M350HE

MM-DXC010

MM-DXC010

MM-DXC010

MM-DXC010

MM-DXC010

MM-DXC010

Reference

Index | Air Handling, HRV & Applied

Air Handling Unit

Interface for Digital

Inverters

Outdoor Unit

158

158

158

156

157

157

157

158

155

155

156

156

154

154

155

155

153

153

154

154

152

152

152

153

150

151

151

151

Page

No

150

150

MM-DXV080

MM-DXV080

MM-DXV080

MM-DXV140

MM-DXV140

MM-DXV140

MM-DXV280

MM-DXV280

RAV-SM304ATP-E

RAV-SM404ATP-E

RAV-SM564ATP-E

RAV-SM804ATP-E

RAV-SM1104ATP-E

RAV-SM1404ATP-E

RAV-SM1603AT-E

RAV-SM2244AT8-E

RAV-SM2804T8-E

RAV-SM2804T8-E

Section

Air Handling Unit

Interface for Super

Digital Inverters

Indoor Unit

Applied Products & Air to Water

RAV-CT101CH-M

RAV-CT101CH-L

Air Curtain - Free

Hanging - Digital

Inverter

RAV-CT151CH-M

RAV-CT151CH-L

RAV-CT201CH-M

RAV-CT201CH-L

RAV-CT251CH-M

RAV-CT251CH-L

RAV-CT101CH-M

RAV-CT101CH-L

RAV-CT151CH-M

RAV-CT151CH-M

RAV-CT151CH-L

RAV-CT151CH-L

Air Curtain - Free

Hanging - Super

Digital Inverter

RAV-CT201CH-M

RAV-CT201CH-M

RAV-CT201CH-L

RAV-CT201CH-L

RAV-CT251CH-M

RAV-CT251CH-L

Outdoor Unit

RAV-SP404AT-E

RAV-SP564ATP-E

RAV-SP804ATP-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1604AT8-E

159

160

160

161

Page

No

59

159

161

161

168

168

169

169

167

167

168

168

166

166

167

167

163

166

166

169

169

170

170

170

170

RAV-SM804ATP-E

RAV-SM804ATP-E

RAV-SM1104ATP-E

RAV-SM1104ATP-E

RAV-SM1404ATP-E

RAV-SM1404ATP-E

RAV-SM1603AT-E

RAV-SM1603AT-E

RAV-SP804ATP-E

RAV-SP804ATP-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1604AT8-E

RAV-SP1604AT8-E

Section Indoor Unit

RAV-CT101UH-M

RAV-CT101UH-L

RAV-CT151UH-M

Air Curtain - Cassette

Type - Digital

Inverter

RAV-CT151UH-L

RAV-CT201UH-M

RAV-CT201UH-L

RAV-CT251UH-M

RAV-CT251UH-L

RAV-CT101UH-M

RAV-CT101UH-L

RAV-CT151UH-M

RAV-CT151UH-M

RAV-CT151UH-L

Air Curtain - Cassette

Type - Super Digital

Inverter

RAV-CT151UH-L

RAV-CT201UH-M

RAV-CT201UH-M

RAV-CT201UH-L

RAV-CT201UH-L

RAV-CT251UH-M

RAV-CT251UH-L

RAV-CT101BH-M

RAV-CT101BH-L

RAV-CT151BH-M

Air Curtain - Built-In -

Digital Inverter

RAV-CT151BH-L

RAV-CT201BH-M

RAV-CT201BH-L

RAV-CT251BH-M

RAV-CT251BH-L

Air Curtain - Built-In -

Super Digital Inverter

RAV-CT101BH-M

RAV-CT101BH-L

Reference

Index | Applied Products

177

177

178

178

176

176

177

177

175

175

176

176

174

174

175

175

173

173

174

174

172

172

173

173

171

171

172

172

Page

No

171

171

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1604AT8-E

RAV-SP1604AT8-E

RAV-SM804ATP-E

RAV-SM804ATP-E

RAV-SM1104ATP-E

RAV-SM1104ATP-E

RAV-SM1404ATP-E

RAV-SM1404ATP-E

RAV-SM1603AT-E

RAV-SM1603AT-E

RAV-SP804ATP-E

RAV-SP804ATP-E

Outdoor Unit

RAV-SM804ATP-E

RAV-SM804ATP-E

RAV-SM1104ATP-E

RAV-SM1104ATP-E

RAV-SM1404ATP-E

RAV-SM1404ATP-E

RAV-SM1603AT-E

RAV-SM1603AT-E

RAV-SP804ATP-E

RAV-SP804ATP-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

Section Indoor Unit

RAV-CT151BH-M

RAV-CT151BH-M

RAV-CT151BH-L

RAV-CT151BH-L

Air Curtain - Built-In -

Super Digital Inverter

RAV-CT201BH-M

RAV-CT201BH-M

RAV-CT201BH-L

RAV-CT201BH-L

RAV-CT251BH-M

RAV-CT251BH-L

RAV-CT101CH-M

RAV-CT101CH-L

RAV-CT151CH-M

RAV-CT151CH-L

Air Curtain - Free

Hanging - VRF

RAV-CT201CH-M

RAV-CT201CH-L

RAV-CT251CH-M

RAV-CT251CH-L

RAV-CT101UH-M

RAV-CT101UH-L

RAV-CT151UH-M

Air Curtain - Cassette

Type - VRF

RAV-CT151UH-L

RAV-CT201UH-M

RAV-CT201UH-L

Air Curtain - Built-

In - VRF

RAV-CT251UH-M

RAV-CT251UH-L

RAV-CT101BH-M

RAV-CT101BH-L

RAV-CT151BH-M

RAV-CT151BH-L

Outdoor Unit

RAV-SP1104AT-E

RAV-SP1104AT8-E

RAV-SP1104AT-E

RAV-SP1104AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1404AT-E

RAV-SP1404AT8-E

RAV-SP1604AT8-E

RAV-SP1604AT8-E

183

183

183

182

182

182

182

183

182

182

182

182

181

181

181

181

181

181

181

181

180

180

180

180

179

179

179

179

Page

No

178

178

Reference

Index | Applied Products, Air to Water & Misc

Section

Air Curtain - Built-

In - VRF

Indoor Unit

RAV-CT151BH-L

RAV-CT201BH-M

RAV-CT201BH-L

RAV-CT251BH-M

RAV-CT251BH-L

Outdoor Unit

Estia - Outdoor Units

- Standard - Single

Phase

Estia - Outdoor Units

- Standard - Three

Phase

HWS-804H-E1

HWS-1104H-E1

HWS-1404H-E1

HWS-1104H8-E1

HWS-1404H8-E1

HWS-1604H8-E1

Estia - Hot Water

Tanks - Standard

HWS-1501CSHM3-UK

HWS-2101CSHM3-UK

HWS-3001CSHM3-UK

HWS-804XWHM3-E1

HWS-804XWHT6-E1

Estia - Hydro Units -

Standard

HWS-1404XWHM3-E1

HWS-1404XWHT6-E1

HWS-1404XWHT9-E1

Estia - Outdoor Units

- High Temperature -

Single Phase

Estia - Hot Water

Tanks - High

Temperature

HWS-1501CSHM3-UK

HWS-2101CSHM3-UK

HWS-3001CSHM3-UK

HWS-P804XWHM3-E1

HWS-P804XWHT6-E1

Estia - Hydro Units -

High Temperature

HWS-P804XWHT6-E1

HWS-1104XWHM3-E1

HWS-1104XWHT6-E1

HWS-1104XWHT9-E1

HWS-P804HR-E1

HWS-P1104HR-E1

192

193

193

193

191

191

192

192

189

190

190

191

188

188

189

189

185

187

187

187

184

184

185

185

183

183

183

184

Page

No

183

183

Section

Controls & Accessories

Wired & Wireless Remote Controllers

Centralised Remote Controllers

Centralised Remote Controllers - PC Based

BMS Interfaces

Indoor Unit Wiring Adapters

Outdoor Unit Wiring Adapters

Leak Detection

Brackets, Trays, Cages & Other Accessories

Toshiba Rewards

Introduction

Warranty

Rewards Gift Cards

Toshiba Unit & Installation Tools

Marketing Contribution & Project Support

Application

Reference/Faults

RAV Fault Codes

VRF Fault Codes

Replacement Technology Tables

Conditions & Conversions

Index

Terms and Conditions

223

224

232

215

216

218

222

211

212

213

207

208

209

210

197

198

199

202

Page

No

195

196

203

204

206

Reference

Terms and Conditions

The use of this product guide is subject to the following terms of use:

The term ‘AMP Air Conditioning’, ‘AMP’, ‘AMP Air’, ’AMP

Diamonds’, ‘the Diamond scheme’ or ‘us’ or ‘we’ refers to AMP

Air Conditioning Limited. Our registered office is Blenheim

House, Blenheim Court, Brownfields, Welwyn Garden

City, Herts, AL7 1AD. Our company registration number is

2371708. The term ‘you’ or ‘your’ refers to the user or viewer of our product guide.

»

The content of this product guide is for your general information and use only. It is subject to change without notice and does not form part of any contract.

»

Prices within this guide are subject to change without notice.

»

Neither we nor any third parties provide any warranty or guarantee as to the accuracy, completeness or suitability of the information and materials found or offered in this product guide for any particular purpose. You acknowledge that such information and materials may contain inaccuracies or errors and we expressly exclude liability for any such inaccuracies or errors to the fullest extent permitted by law.

»

This product guide contains material which is owned by or licensed to us. This material includes, but is not limited to, the design, layout, look, appearance, photographs and graphics. Reproduction is prohibited other than in accordance with the copyright notice, which forms part of these terms and conditions.

»

Product images within this product guide are for illustrative purposes only and do not necessarily represent the exact products, services or ideas in the context in which they are found. Actual products may differ from those shown.

»

All trademarks reproduced in this guide, which are not the property of, or licensed to AMP, are acknowledged in the guide.

»

Unauthorised use of this product guide may give to a claim for damages and/or be a criminal offence.

»

This product guide provides links to third party websites. These links are provided for your convenience to provide further information. They do not signify that we endorse the website(s). We have no responsibility for the content of the linked website(s).

»

Your use of this product guide and any dispute arising out of such use of the website is subject to the laws of

England and Wales.

»

In no event will we be liable for any loss or damage including without limitation, indirect or consequential loss or damage, or any loss or damage whatsoever arising from loss of data or profits arising out of, or in connection with, the use of this product guide.

For more information about AMP or these terms and conditions, please contact us:

Tel:

Email:

01707 378 670 [email protected]

Address: AMP Air Conditioning

Blenheim House

Blenheim Court

Brownfields

Welwyn Garden City

Herts AL7 1AD

AMP Air Conditioning is an ISO 14001:2004 and 9001:2008 accredited company.

R R

ISO 14001:2004

REGISTERED COMPANY

Certificate No. EN1749

ISO 9001:2008

REGISTERED COMPANY

Certificate No. CA14723

ampair.co.uk | 01707 378 670 | [email protected]

AMP Air Conditioning, Blenheim House, Blenheim Court, Brownfields, Welwyn Garden City, Herts AL7 1AD

© AMP Air Conditioning Ltd, 2016

Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement