the smartest modular i/o system

the smartest modular i/o system
Automation systems
SMART PLATFORM
One software – One connection – One minute
Omron‘s Smart Platform is designed to make machine automation easy. It provides seamless, drag-and-drop
integration of all automation components in your machine. From sensor to controller, from HMI to drive, all devices are
accessible through one connection using a single software suite, CX-One.
Built-in distributed intelligence in Omron devices means less time programming and troubleshooting.
Every one claims ease of use, a short movie explains how easy programming and configuration really can be:
www.smartplatform.info
6
Programmable logic controllers (PLC) 1 Human machine interfaces (HMI)
3
Product overview
46
8
Selection table
Compact PLC
10
PC based HMI
48
CP1E CPU units
13
Selection table
52
New
CP1L CPU units
14
HMI-Connection
55
CP1W/CPM1A Expansion Units
15
HMI-NSJ
CPM2C CPU units
16
CPM2C expansion units
17
CP1H CPU units
18
CJ-Series CPU units
19
Rack PLC
Wireless communication
HMI-NS
NSJ12/NSJ10
56
NSJ8/NSJ5
58
NS15/NS12/NS10/NS8
60
NS5
61
NS5 Handheld
62
CJ-Series power supplies, expansions
20
Accessories NSJ/NS
CJ-Series digital I/O units
21
Selection table
CJ-Series analog I/O and control units
22
HMI-NQ
NQ5/NQ3
65
CJ-Series motion/position control units
24
HMI-NT
NT11
66
CJ-Series communication units
25
NT2S
67
CS-Series CPU units
26
CS-Series power supplies, backplanes
27
CS-Series digital I/O units
28
CS-Series analog and process I/O units
29
CS-Series position/motion control units
31
CS-Series communication units
32
WE70
33
Remote I/O
2
Product overview
34
Selection table
36
Wireless
DyaloX
New
Modular PLC
Remote I/O
Product overview
SmartSlice I/O system
38
Compact I/O DRT2
39
Compact I/O CRT1
40
Compact I/O SRT2
41
Field I/O DRT2
42
Field I/O CRT1B
43
Field I/O SRT2
44
WD30/WT30
45
63
64
7
Automation systems
Automation systems – Table of contents
Programmable logic controllers (PLC)
KNOW ONE ... KNOW THEM ALL!
When you need simple and economical automation tasks, or up to complex system solutions,
Omron's PLC line-up can do it.
Unique in the market place is that both Omron's Compact PLCs and the Modular PLCs shares the
same architecture. Programs are fully compatible for memory allocations and instructions.
• One scalable PLC family to match exactly with your application
• Transparent communication routing through different networks
• The best size/performance ratio in the industry
Compact
Max. I/O size?
8
up to 160
up to 180
up to 192
up to 320
CP1E
CP1L
CPM2C
CP1H
Page 13
Page 14
Page 16
Page 18
PLC
1
Type of PLC needed?
Modular
Rack
Max. I/O size?
Max. I/O size?
up to 640
up to 2560
up to 5120
Dual
redundancy
Built in
Ethernet IP
CJ1M
CJ1G/CJ2H
CJ2H
CS1G/H
CS1D
Page 19
Page 19
Page 19
Page 26
Page 26
9
Selection table
Compact PLC series
Model
Built-in
CP1E
Digital I/O 20 to 40
Interrupt inputs 6
CP1L
CPM2C
10 to 32
40
2 to 6
2 to 4
8
1 (20 kHz) + 2 to 4 (2 kHz)
4 (1 MHz or 100 kHz)
Counter inputs 6 (10 kHz) or 4 (10kHz) + 2 (100 kHz) 4 (100 kHz)
Pulse outputs 1 (10 kHz) + 1 (100 kHz)
2 (100 kHz)
2 (10 kHz)
4 (1 MHz or 100 kHz)
CPU features/ AC only (DC planned)
option boards supports 170 instructions
RS232 port built-in on E-N model
USB programming port
no RTC
AC & DC power supply
supports 500 instructions
USB programming port
Optional display
DC power supply
2nd serial port via converter unit
Built-in AC or DC power supply
4 analog in/2 analog out (XA model)
2 serial communication board plugins
1 simple analog input
1 analog setting
Removable terminal blocks
USB programming port
180
106 to 192
320
0.1 μs
0.26 to 0.64 μs
0.1 μs
1-10 kSteps
4 kWords
20 kSteps
10-32 kWords
2 kWords
32 kWords
No, memory casette
–
12 ch / expansion
8-bit, 12-bit resolution
U, I, TC, Pt100
Up to 4×(2 in + 1 out)
12-bit resolution
U, I, TC, Pt100
Max. digital I/O points 160
Execution time 1.1 μs
(bit instruction)
Program memory 2-8 kSteps
Data memory 2-8 kWords
CompactFlash memory –
Analog I/O 12 ch / expansion
8-bit, 12-bit resolution
U, I, TC, Pt100
Special function units –
Industrial networks Serial communications
Fieldbus I/O link PROFIBUS-DP
CompoBus/S
DeviceNet
Page 13
Up to approx.
30 inputs/outputs
(8, 13, 14-bit resolution
U, I, TC, PT100)
Temperature control
Protocol macro
RFID sensor unit
Ethernet (100/10 Base-TX, AutoMDIX)
Serial communications
Serial communications
Ethernet (100 BASE-Tx)
Controller link
Serial communications
CompoBus/S
DeviceNet
CAN
PROFIBUS-DP
CompoBus/S
PROFIBUS-DP
CompoBus/S
DeviceNet
DeviceNet
CompoBus/S
DeviceNet
PROFIBUS-DP
CAN
14
16
18
Fieldbus master –
10
CP1H
10 to 60
Programmable logic controllers
Rack PLC series
PLC
Modular PLC series
CJ1M
Digital I/O 16
Interrupt inputs 4
CJ1G
CS1G/H
CS1D
–
Counter inputs 2 (100 kHz)
–
Pulse outputs 2 (100 kHz)
–
CPU features/ Choice of models with
option boards and without built-in I/O
Ethernet CPU (3 models)
Loop control CPU
(4 models)
Max. digital I/O points 160 to 640
CJ2H
–
1
Model
Built-in
Built-in EtherNet/IP port
2 serial ports
Loop control board
Loop control board
Duplex CPU,
Power supply and
communications
960/1280
2560
960 to 5120
960 to 5,120
0.04/0.02 μs
0.016 μs
0.04/0.02 μs
0.04/0.02 μs
Program memory 5 to 20 kSteps
10 to 250 kSteps
50 to 400 kSteps
10 to 250 kSteps
10 to 250 kSteps
Data memory 32 kWords
64 to 448 kWords
160 to 832 kWords
64 to 448 kWords
64 to 448 kWords
Up to 36×8 points
13-bit resolution
U, I,
15-bit resolution
TC, Pt100, PT1000 inputs
Up to 36×8 points
13-bit resolution
U, I,
15-bit resolution
TC, Pt100, PT1000 inputs
Up to 80×8 points,
13 bit resolution or
80×4 points,
16 bit resolution
U, I, TC, Pt100, process I/O
Up to 75×8 points,
13 bit resolution or
75×4 points,
16 bit resolution
U, I, TC, Pt100, process I/O
Execution time 0.1 μs
(bit instruction)
CompactFlash memory Up to 512 MB
Analog I/O Up to 20×8 points
12 bit resolution
U, I,
15 bit resolution
TC, Pt100, Pt1000 inputs
Special function units Temperature control
High-speed counters (500 kHz)
SSI encoder input
Position control
Protocol macro
RFID sensor unit
Temperature control
SSI encoder input
High-speed counters (500 kHz)
Position control
Motion control
Process control
Protocol macro
RFID sensor unit
Industrial networks Ethernet (100 BASE-Tx)
EtherNet/IP
Controller link
Serial communications
(RS232, RS422, RS485)
Fieldbus master DeviceNet
CAN (freely configurable)
PROFIBUS-DP
PROFINET-IO
CompoNet
CompoBus/S
DeviceNet
PROFIBUS-DP
CAN/CANopen
CompoBus/S
Fieldbus I/O link DeviceNet
PROFIBUS-DP
CAN
DeviceNet
PROFIBUS-DP
CAN/CANopen
Page 19
26
11
12
CP1E CPU units
Compact PLC
1
Omron’s CP1E series targets a ‘lean’ automation solution, but still offers all functionality you need to control relatively simple application, including outstanding positioning capability. The CP1E comes with 20, 30 or 40 I/O built-in and can be expanded
with a wide range of CP1W or CPM1A expansion units up to 160 I/O points. It uses a
standard USB port for programming and monitoring. It comes standard with a serial
communication port, and the E-N type offers an optional plug-in serial communication port. As the CP1E series shares the same architecture as the CP1L, CP1H, CJ1,
and CS1 series, programs are compatible for memory allocations and instructions.
PLC
Easy, efficient & economic
Ordering information
CP1E-E CPU types (basic model)
Input/output
points
Expandable up to*1 Program Capacity Data Memory
capacity
Logic execution
speed
Power supply Output type
Built-in functions
Order code
12/8
20 points
2 kSteps
2 kWords
1.1 μs
85 to 264 VAC Relay
6x10 kHz inputs
CP1E-E20DR-A
18/12
150 points
2 kSteps
2 kWords
1.1 μs
85 to 264 VAC Relay
6x10 kHz inputs
CP1E-E30DR-A
24/16
160 points
2 kSteps
2 kWords
1.1 μs
85 to 264 VAC Relay
6x10 kHz inputs
CP1E-E40DR-A
Order code
*1
CP1E CPU series can be expanded with CP1W-, or CPM1A expansion units
CP1E-N CPU types (application model)
Input/output
points
Expandable up to*1 Program Capacity Data Memory
capacity
Logic execution
speed
Power supply Output type
Built-in functions
12/8
20 points
1.1 μs
85 to 264 VAC Relay
4x10 kHz & 2x100 kHz inputs; CP1E-N20DR-A
1x10 kHz & 1x100 kHz outputs
8 kSteps
8 kWords
Transistor (sinking)
4x10 kHz & 2x100 kHz inputs; CP1E-N20DT-A
1x10 kHz & 1x100 kHz outputs
Transistor (sourcing) 4x10 kHz & 2x100 kHz inputs; CP1E-N20DT1-A
1x10 kHz & 1x100 kHz outputs
18/12
150 points
8 kSteps
8 kWords
1.1 μs
85 to 264 VAC Relay
Transistor (sinking)
4x10 kHz & 2x100 kHz inputs; CP1E-E30DR-A
1x10 kHz & 1x100 kHz outputs
4x10 kHz & 2x100 kHz inputs; CP1E-E30DT-A
1x10 kHz & 1x100 kHz outputs
Transistor (sourcing) 4x10 kHz & 2x100 kHz inputs; CP1E-E30DT1-A
1x10 kHz & 1x100 kHz outputs
24/16
160 points
8 kSteps
8 kWords
1.1 μs
85 to 264 VAC Relay
Transistor (sinking)
4x10 kHz & 2x100 kHz inputs; CP1E-E40DR-A
1x10 kHz & 1x100 kHz outputs
4x10 kHz & 2x100 kHz inputs; CP1E-E40DT-A
1x10 kHz & 1x100 kHz outputs
Transistor (sourcing) 4x10 kHz & 2x100 kHz inputs; CP1E-E40DT1-A
1x10 kHz & 1x100 kHz outputs
*1
CP1E CPU series can be expanded with CP1W-, or CPM1A expansion units
Accessories
Type
Remarks
Order code
RS-232C Option Board
Plug-in board (D-Sub, 9 pins, female) E-N 30p and 40p types only
CP1W-CIF01
RS-422A/485 Option board
Plug-in board (Terminal block)
CP1W-CIF11
RS422A/485 (isolated) option board
Plug-in board (D-Sub, 9 pins, female) E-N 30p and 40p types only
CP1W-CIF12
USB Programming cable
A-type male to B-type male (length: 1.8m)
CP1W-CN221
13
CP1L CPU units
Compact PLC
The compact machine controller
When it comes to controllers for compact machines, Omron’s CP1L series offers
the compactness of a micro-PLC with the capability of a modular PLC. It provides all
the functionality you need to control your machine, including outstanding positioning
capability. The CP1L comes with 14, 20, 30, 40, or 60 I/O built-in and can be expanded with a wide range of CP1W or CPM1A expansion units up to 180 I/O points. It uses
a standard USB port for programming and monitoring and offers two optional plug-in
serial communication ports, of which one can be used for a display or Ethernet option
as well. As the CP1L series shares the same architecture as the CP1E, CP1H, CJ1,
and CS1 series, programs are compatible for memory allocations and instructions.
Ordering information
Input points
Output points Expandable
up to*1
Program
Capacity
Data Memory Logic
capacity
execution
speed
Power supply
Output type
Built-in functions
6 points
4 points
5 kSteps
10 kWords
84 to 264 VAC
Relay output
4 Encoder inputs (100 kHz) CP1L-L10DR-A
2 Interrupts/counters
20.4 to 26.4 VDC Relay output
4 Encoder inputs (100 kHz) CP1L-L10DR-D
2 Interrupts/counters
10 points
0.55 μs
Order code
Transistor output (sink type)
4 Encoder inputs (100 kHz) CP1L-L10DT-D
Transistor output (source type) 2 Pulse outputs (100 kHz) CP1L-L10DT1-D
2 Interrupts/Counters
8 points
6 points
54 points
5 kSteps
10 kWords
0.55 μs
85 to 264 VAC
Relay output
4 Encoder inputs (100 kHz) CP1L-L14DR-A
4 Interrupts/counters
20.4 to 26.4 VDC Relay output
4 Encoder inputs (100 kHz) CP1L-L14DR-D
4 Interrupts/counters
Transistor ouput (sink type)
4 Encoder inputs (100 kHz) CP1L-L14DT-D
Transistor output (source type) 2 Pulse outputs (100kHz) CP1L-L14DT1-D
4 Interrupts/Counters
12 points
8 points
60 points
5 kSteps
10 kWords
0.55 μs
85 to 264 VAC
Relay output
4 Encoder inputs (100 kHz) CP1L-L20DR-A
6 Interrupts/counters
20.4 to 26.4 VDC Relay output
4 Encoder inputs (100 kHz) CP1L-L20DR-D
6 Interrupts/counters
Transistor ouput (sink type)
4 Encoder inputs (100 kHz) CP1L-L20DT-D
Transistor output (source type) 2 Pulse outputs (100kHz) CP1L-L20DT1-D
6 Interrupts/Counters
18 points
12 points
150 points
10 kSteps
32 kWords
0.55 μs
85 to 264 VAC
Relay output
4 Encoder inputs (100 kHz) CP1L-M30DR-A
6 Interrupts/counters
20.4 to 26.4 VDC Relay output
4 Encoder inputs (100 kHz) CP1L-M30DR-D
6 Interrupts/counters
Transistor ouput (sink type)
4 Encoder inputs (100 kHz) CP1L-M30DT-D
Transistor output (source type) 2 Pulse outputs (100kHz) CP1L-M30DT1-D
6 Interrupts/Counters
24 points
16 points
160 points
10 kSteps
32 kWords
0.55 μs
85 to 264 VAC
Relay output
4 Encoder inputs (100 kHz) CP1L-M40DR-A
6 Interrupts/counters
20.4 to 26.4 VDC Relay output
4 Encoder inputs (100 kHz) CP1L-M40DR-D
6 Interrupts/counters
Transistor ouput (sink type)
4 Encoder inputs (100 kHz) CP1L-M40DT-D
Transistor output (source type) 2 Pulse outputs (100kHz) CP1L-M40DT1-D
6 Interrupts/Counters
36 points
24 points
180 points
10 kSteps
32 kWords
0.55 μs
85 to 264 VAC
Relay output
4 Encoder inputs (100 kHz) CP1L-M60DR-A
6 Interrupts/counters
20.4 to 26.4 VDC Relay output
4 Encoder inputs (100 kHz) CP1L-M60DR-D
6 Interrupts/counters
Transistor output (sink type)
4 Encoder inputs (100 kHz) CP1L-M60DT-D
Transistor output (source type) 2 Pulse outputs (100 kHz) CP1L-M60DT1-D
6 Interrupts/Counters
*1
CP1L CPU series can be expanded with CP1W-, or CPM1A expansion units
Accessories
Type
Remarks
Order code
RS-232C Option Board
Plug-in board (D-Sub, 9 pins, female)
CP1W-CIF01
RS-422A/485 Option board
Plug-in board (Terminal block)
CP1W-CIF11
RS422A/485 (isolated) option board
Plug-in board (D-Sub, 9 pins, female)
CP1W-CIF12
Ethernet option board
Plug-in board (not for 10 points CPU)
CP1W-CIF41
Memory cassette
512 kWords (upload/download program)
CP1W-ME05M
USB Programming cable
A-type male to B-type male (length: 1.8m)
CP1W-CN221
LCD display
4 rows x 12 characters
CP1W-DAM01
14
CP1W/CPM1A Expansion Units
Compact PLC
Expand the capacity of your compact PLC
1
PLC
A wide variety of expansion units such as Digital I/O, Analog I/O and Remote I/O are
available to create the application you need. These CP1W / CPM1A expansion units
can be used for CPM1A-, CPM2A-, CP1L-, and CP1H series PLC.
Ordering information
Unit
Size in mm
(HxWxD)
Output type
Inputs
Outputs
CP1W model
CPM1A model
Expansion I/O units
90x66x50
–
8
–
CP1W-8ED
CPM1A-8ED
Relay
–
8
CP1W-8ER
CPM1A-8ER
Transistor (sinking)
CP1W-8ET
CPM1A-8ET
Transistor (sourcing)
CP1W-8ET1
CPM1A-8ET1
90x86x50
Relay
–
16
CP1W-16ER
–
90x86x50
Relay
12
8
CP1W-20EDR1
CPM1A-20EDR1
Transistor (sinking)
CP1W-20EDT
CPM1A-20EDT
Transistor (sourcing)
CP1W-20EDT1
CPM1A-20EDT1
CP1W-40EDR
CPM1A-40EDR
Transistor (sinking)
CP1W-40EDT
CPM1A-40EDT
Transistor (sourcing)
CP1W-40EDT1
CPM1A-40EDT1
90x150x50
Analog I/O units
Temperature sensor units
Order code
Relay
24
16
90x66x50
Analog (resolution 1/256)
2
1
–
CPM1A-MAD01
90x86x50
Analog (resolution 1/6000)
2
1
CP1W-MAD11
CPM1A-MAD11
90x86x50
Analog (resolution 1/6000)
4
–
CP1W-AD041
CPM1A-AD041
90x86x50
Analog (resolution 1/6000)
–
4
CP1W-DA041
CPM1A-DA041
90x86x50
Thermocouple input
2
–
CP1W-TS001
CPM1A-TS001
Thermocouple input
4
–
CP1W-TS002
CPM1A-TS002
Platinum resistance input
2
–
CP1W-TS101
CPM1A-TS101
Platinum resistance input
4
–
CP1W-TS102
CPM1A-TS102
Platinum resistance input and
voltage/current output
2
1
–
CPM1A-TS101-DA
DeviceNet I/O link unit
90x66x50
–
I/O link of 32 input bits and 32 output bits
–
CPM1A-DRT21
PROFIBUS-DP I/O link unit
90x66x50
–
I/O link of 16 input bits and 16 output bits
–
CPM1A-PRT21
CompoBus/S I/O link unit
90x66x50
–
I/O link of 8 input bits and 8 output bits
CP1W-SRT21
CPM1A-SRT21
15
CPM2C CPU units
Compact PLC
The versatile slim-line controller
An extensive range of models ensures efficient machine control in an ultra-compact
package. CPU units are available with relay or transistor output, terminal block or
various connector options, and an optional real-time clock function. Select the output
type, number of I/O points and other specifications to meet your needs. Expansion
I/O units with 8 to 32 I/O points make it possible to configure a control system with
a maximum of 192 I/O points.
•
•
•
•
•
Space-saving slim outline, high-density I/O
10-32 I/O points per CPU, transistor or relay outputs
20 kHz counter input, two 10 kHz pulse outputs integrated
Two communication ports built-in, freely accessible
Digital, analog, and fieldbus expansion units
Ordering information
Input
points
6 points
Output
points
Program
capacity
Data
memory
capacity
Logic
execution
speed
Size in mm
(HxWxD)
I/O Connectors
4 points 4 kWords
2 kWords
0.64 μs
90x33x65
2 Terminal blocks Relay
2 Fujitsu (24 pt)
2 MIL (20 pt)
12 points
8 points 4 kWords
2 kWords
0.64 μs
90x33x65
2 kWords
0.64 μs
90x33x65
Order code
1 Encoder input (20 kHz)
–
CPM2C-10CDR-D
Yes
CPM2C-10C1DR-D
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
–
CPM2C-10CDT1C-D
Yes
CPM2C-10C1DT1C-D
Transistor
(source type)
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
–
CPM2C-10CDT1M-D
Yes
CPM2C-10C1DT1M-D
1 Encoder input (20 kHz)
–
CPM2C-20CDR-D
Yes
CPM2C-20C1DR-D
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
–
CPM2C-20CDT1C-D
Yes
CPM2C-20C1DT1C-D
Transistor
(source type)
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
–
CPM2C-20CDT1M-D
Yes
CPM2C-20C1DT1M-D
2 Fujitsu (24 pt)
Transistor
(source type)
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
–
CPM2C-32CDT1C-D
2 MIL (20 pt)
Transistor
(source type)
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
–
CPM2C-32CDT1M-D
6 points
4 points 4 kWords
2 kWords
0.64 μs
90x40x65
1 Fujitsu (24 pt)
Transistor
(source type)
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
Programmable Slave with
DeviceNet slave and
CompoBus/S Master
Yes
CPM2C-S110C-DRT
6 points
4 points 4 kWords
2 kWords
0.64 μs
90x40x65
1 Fujitsu (24 pt)
Transistor
(source type)
1 Encoder input (20 kHz)
2 Pulse output (10 kHz)
CompoBus/S Master
Yes
CPM2C-S110C
Note: All CPU's are available only with DC supply voltage (CPM2C-PA201 can be used as power supply).
CPU's with sourcing transistor outputs are also available with sinking transistor outputs.
MIL = connector according to MIL-C-83503 (compatible with DIN 41651/IEC 60603-1).
16
Real time
clock
Transistor
(source type)
2 MIL (20 pt)
16 points 4 kWords
Built-in functions
Transistor
(source type)
2 Terminal blocks Relay
2 Fujitsu (24 pt)
16 points
Output method
CPM2C expansion units
Compact PLC
Expand the capacity of your CPM2C PLC
1
PLC
Expansion I/O units with 8 to 32 I/O points make it possible to configure a control
system with a maximum of 192 I/O points
Ordering information
Unit
Output type
I/O Connectors
Inputs
Outputs
Order code
Expansion I/O units
–
1 Fujitsu (24 pt)
8
–
CPM2C-8EDC
16
–
–
8
1 MIL (20 pt)
–
1 Fujitsu (24 pt)
CPM2C-8EDM
1 MIL (20 pt)
Relay
1 Terminal block
Transistor output (source type)
1 Fujitsu (24 pt)
CPM2C-16EDM
1 Fujitsu (24 pt)
CPM2C-8ER
CPM2C-8ET1C
1 MIL (20 pt)
Transistor output (source type)
CPM2C-16EDC
CPM2C-8ET1M
–
16
1 MIL (20 pt)
CPM2C-16ET1C
CPM2C-16ET1M
Relay
2 Terminal blocks
6
4
CPM2C-10EDR
Relay
2 Terminal blocks
12
8
CPM2C-20EDR
Transistor output (source type)
2 Fujitsu (24 pt)
16
8
CPM2C-24EDT1C
16
16
2 MIL (20 pt)
Transistor output (source type)
2 Fujitsu (24 pt)
CPM2C-24EDT1M
2 MIL (20 pt)
CPM2C-32EDT1C
CPM2C-32EDT1M
Analog I/O units
Analog (resolution 1/6000)
2 Terminal blocks
2
1
CPM2C-MAD11
Temperature sensor units
Thermocouple input
1 Terminal block
2
–
CPM2C-TS001
Platinum resistance input
1 Terminal block
2
–
CPM2C-TS101
CompoBus/S I/O link unit
–
1 Terminal block
I/O link of 8 input bits and 8 output bits
CPM2C-SRT21
RS-232C and RS422 adapter units
–
1 D-sub 9-pin
RS-232C
CPM2C-CIF01-V1
1 Terminal block and
1 D-sub 9-pin
RS-232C and RS422
CPM2C-CIF11
Note: Expansion I/O units with sourcing transistor outputs are also available with sinking transistor outputs.
MIL = connector according to MIL-C-83503 (compatible with DIN 41651/IEC 60603-1).
17
CP1H CPU units
Compact PLC
The All-in-One PLC
Designed for compact machines, it combines the compactness of a micro-PLC and
the power of a modular PLC. Four built-in high-speed counters and four pulse outputs
are ideal for multi-axis positioning control. The CP1H-XA comes with 4 analog inputs
and 2 analog outputs built-in. This makes it suitable for simple loop control, using the
PLC's advanced PID control function with auto-tuning. The CP1H can be expanded
with CPM1 I/Os and supports up to 2 CJ1 special I/O units. This means that it is open
to popular fieldbuses and supports all communication units of the CJ1 series.
•
•
•
•
•
Up to 1 MHz for inputs/outputs
CJ1M-compatible instruction set and execution speed
4 analog inputs and 2 analog outputs for the XA model
USB port for easy communication, programming and configuration
Supports PROFIBUS, DeviceNet, CAN and Ethernet
Ordering information
Input
points
Output
points
Expandable up Program
to
capacity
(digital I/O)*1
Data
memory
capacity
24 points
16 points
320 points
32 kWords
20 kSteps
Logic
execution
speed
Power supply Output method
100 ns
85 to Relay output
264 VAC
20.4 to Transistor output
26.4 VDC (sink type)
Transistor
(source type)
24 points
16 points
320 points
20 kSteps
32 kWords
100 ns
85 to Relay output
264 VAC
20.4 to Transistor output
26.4 VDC (sink type)
Transistor
(source type)
12 points
*1
8 points
300 points
20 kSteps
32 kWords
100 ns
20.4 to Transistor
26.4 VDC (sink type)
Built-in functions
4 Encoder inputs (100 kHz)
8 Interrupts/Counters
Order code
–
4 Encoder inputs (100 kHz)
4 Pulse outputs (100 kHz)
8 Interrupts/counters
4 Encoder inputs (100 kHz)
8 Interrupts/Counters
4 Encoder inputs (100 kHz)
4 Pulse outputs (100 kHz)
8 Interrupts/Counters
4 Encoder inputs
(2×1 MHz + 2×100 kHz)
4 Pulse outputs
(2×1 MHz + 2×100 kHz)
6 Interrupts/Counters
CP1H-X40DR-A
CP1H-X40DT-D
CP1H-X40DT1-D
4 Analog in
2 Analog out
(res: 1/12000)
CP1H-XA40DR-A
CP1H-XA40DT-D
CP1H-XA40DT1-D
–
CP1H-Y20DT-D
CP1H CPU series can be expanded with CPM1A expansion units and CJ1 Special I/O units.
Accessories
Type
Remarks
Order code
RS-232C option board
Plug-in board (D-Sub, 9 pins, female)
CP1W-CIF01
RS-422A/485 option board
Plug-in board (Terminal block)
CP1W-CIF11
RS422A/485 (isolated) option board
Plug-in board (D-Sub, 9 pins, female)
CP1W-CIF12
Ethernet option board
Plug-in board (not for 10 points CPU)
CP1W-CIF41
Memory cassette
512 kWords (upload/download program)
CP1W-ME05M
Expansion I/O connecting cable
80 cm cable to connect CPM1A I/O
CP1W-CN811
CJ1 expansion unit adapter
Unit to connect CJ1 Special I/O units
CP1W-EXT01
LCD display
4 rows x 12 characters
CP1W-DAM01
18
CJ-Series CPU units
Modular PLC
Fast and powerful CPUs for any task
All CPU units support IEC61131-3 Structured text, Sequential Function Charts and
ladder language. Omron's extensive function block library helps to reduce your programming effort, while you can create your own function blocks to suit your specific
needs.
PLC
The new CJ2 CPU units offer increased capacity, higher performance plus built-in
USB- and ethernet ports, yet are fully compatible to the extensive range of CJ1 I/O
units.
1
The family of CJ1 and CJ2 CPUs range from very small CPUs for simple sequence
control to powerful and fast models that offer total machine control which can handle
up to 2560 I/O points. This enables you to modularize or ’slice’ your machine into logical sections without changing PLC series.
Ordering information
Max. digital
I/O points
2,560
2,560
2,560
2,560
2,560
1,280
1,280
960
960
Program
capacity
400 kSteps
250 kSteps
150 kSteps
100 kSteps
50 kSteps
60 kSteps
Data memory
capacity
Logic execution
speed
832 kWords
16 ns
512 kWords
16 ns
352 kWords
16 ns
160 kWords
16 ns
160 kWords
16 ns
128 kWords
30 kSteps
20 kSteps
10 kSteps
40 ns
64 kWords
40 ns
64 kWords
40 ns
64 kWords
40 ns
Max. I/O
units
Width
5 V current
consumption
Built-in functions
Order code
39
80 mm
820 mA
EtherNet/IP port
CJ2H-CPU68H-EIP
40
49 mm
420 mA
–
CJ2H-CPU68H
39
80 mm
820 mA
EtherNet/IP port
CJ2H-CPU67H-EIP
40
49 mm
420 mA
–
CJ2H-CPU67H
39
80 mm
820 mA
EtherNet/IP port
CJ2H-CPU66H-EIP
40
49 mm
420 mA
–
CJ2H-CPU66H
39
80 mm
820 mA
EtherNet/IP port
CJ2H-CPU65H-EIP
40
49 mm
420 mA
–
CJ2H-CPU65H
39
80 mm
820 mA
EtherNet/IP port
CJ2H-CPU64H-EIP
40
49 mm
420 mA
–
CJ2H-CPU64H
40
69 mm
1,060 mA
Loop control engine (300 blocks)
CJ1G-CPU45P
62 mm
910 mA
–
CJ1G-CPU45H
69 mm
1,060 mA
Loop control engine (300 blocks)
CJ1G-CPU44P
62 mm
910 mA
–
CJ1G-CPU44H
69 mm
1,060 mA
Loop control engine (300 blocks)
CJ1G-CPU43P
62 mm
910 mA
–
CJ1G-CPU43H
69 mm
1,060 mA
Loop control engine (50 blocks)
CJ1G-CPU42P
62 mm
910 mA
–
CJ1G-CPU42H
40
30
30
640
20 kSteps
32 kWords
100 ns
20
49 mm
640 mA
2 Encoder inputs (100 kHz)
2 Pulse outputs (100 kHz)
4 interrupt/counter inputs
CJ1M-CPU23
320
10 kSteps
32 kWords
100 ns
10
49 mm
640 mA
2 Encoder inputs (100 kHz)
2 Pulse outputs (100 kHz)
4 interrupt/counter inputs
CJ1M-CPU22
160
5 kSteps
32 kWords
100 ns
10
49 mm
640 mA
2 Encoder inputs (100 kHz)
2 Pulse outputs (100 kHz)
4 interrupt/counter inputs
CJ1M-CPU21
640
20 kSteps
32 kWords
100 ns
19
62 mm
950 mA
100 base-Tx Ethernet port
CJ1M-CPU13-ETN
20
31 mm
580 mA
–
CJ1M-CPU13
9
62 mm
950 mA
100 base-Tx Ethernet port
CJ1M-CPU12-ETN
10
31 mm
580 mA
–
CJ1M-CPU12
9
62 mm
950 mA
100 base-Tx Ethernet port
CJ1M-CPU11-ETN
10
31 mm
580 mA
–
CJ1M-CPU11
Description
Remarks
Order code
CompactFlash memory card, 128 MB, for all models (not required for operation)
Industrial grade
HMC-EF183
CompactFlash PC-Card adapter
–
HMC-AP001
I/O terminal block (40×M3 screw) for CJ1M-CPU2x
MIL (40 pt)
XW2D-40G6
Servo unit terminal block for 1 axis
–
XW2B-20J6-8A
Servo unit terminal block for 2 axes
–
XW2B-40J6-9A
Connection cable between I/O terminal block and CJ1M-CPU2x ( _ _ _ = length in cm)
MIL (40 pt)
XW2Z-_ _ _ K
SMARTSTEP cable for CJ1M CPU2x, cable length: 1 m
–
XW2Z-100J-A26
W-series servo cable for CJ1M CPU2x, cable length: 1 m
–
XW2Z-100J-A27
CX-One, integrated software for programming and configuration of all Omron control system components
–
CX-ONE-AL_ _ C-E
Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port (length: 2.0 m)
–
CS1W-CN226
Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port (length: 6.0 m)
–
CS1W-CN626
USB to serial conversion cable
–
CS1W-CIF31
320
160
10 kSteps
5 kSteps
32 kWords
32 kWords
100 ns
100 ns
Accessories
Note: MIL = connector according to MIL-C-83503 (compatible with DIN 41651/IEC 60603-1).
19
CJ-Series power supplies, expansions
Modular PLC
Power and flexibility
CJ systems can operate on 24 VDC power supply, or on 100 to 240 VAC mains.
For small-scale systems with mainly digital I/O a low-cost small-capacity power
supply can be used. For systems with many analog I/Os and control/communication
units, it may be necessary to use a larger power supply unit.
Depending on the CPU type, up to 3 expansions can be connected to the CPU 'rack',
giving a total capacity of 40 I/O units. The total length of the expansion cables of one
system may be up to 12 m.
Ordering information
Power supply
Input range
Power
consumption
Output capacity at
5 VDC
Output capacity at
24 VDC
Max. output
power
Features
Width
Order code
21.6 to 26.4 VDC
35 W max.
2.0 A
0.4 A
16.6 W
–
27 mm
CJ1W-PD022
19.2 to 28.8 VDC
50 W max.
5.0 A
0.8 A
25 W
–
60 mm
CJ1W-PD025
85 to 264 VAC
47 to 63 Hz
50 VA max.
2.8 A
0.4 A
14 W
–
45 mm
CJ1W-PA202
100 VA max.
5.0 A
0.8 A
25 W
Run output (SPST relay)
80 mm
CJ1W-PA205R
Maintenance status display
80 mm
CJ1W-PA205C
Width,
Length
Order code
Note: The CJ1W-PD022 has no galvanic isolation
I/O expansion
Type
Description
I/O control unit
Required unit on CPU 'rack' to connect I/O expansions
20 mm
CJ1W-IC101
I/O interface unit
Start unit for each I/O expansion 'rack'. Requires a power supply unit.
31 mm
CJ1W-II101
I/O expansion cable
Connects CJ1W-IC101 or -II101 to the next expansion rack's -II101
0.3 m
CS1W-CN313
0.7 m
CS1W-CN713
2.0 m
CS1W-CN223
3.0 m
CS1W-CN323
5.0 m
CS1W-CN523
10 m
CS1W-CN133
12 m
CS1W-CN133-B2
20
CJ-Series digital I/O units
Modular PLC
8 to 64 points per unit – input, output or
mixed
1
CJ1 units are available with various I/O densities and connection technologies. Up to
16 I/O points can be wired to units with detachable M3 screw terminals or screwless
clamp terminals. High-density 32- and 64- point I/O units are equipped with standard
40-pin 'flatcable'-connectors. Prefabricated cables and wiring terminals are available
for easy interfacing to high-density I/O units.
PLC
Digital I/O units serve as the PLC's interface to achieve fast, reliable sequence
control. A full range of units, from high-speed DC inputs to relay outputs, let you adapt
CJ1 to your needs.
Ordering information
Points
Type
Width
Remarks
Connection type*1
Order code
16
AC input
120 VAC
7 mA
31 mm
–
M3
CJ1W-IA111
8
AC input
240 VAC
10 mA
31 mm
–
M3
CJ1W-IA201
8
DC input
24 VDC
10 mA
31 mm
–
M3
CJ1W-ID201
16
DC input
24 VDC
7 mA
31 mm
–
M3
Screwless
CJ1W-ID211
CJ1W-ID211(SL)
16
DC input
24 VDC
7 mA
31 mm
Fast-response (15 μs ON, 90 μs OFF)
M3
CJ1W-ID212
16
DC input
24 VDC
7 mA
31 mm
Inputs start interrupt tasks in PLC program M3
CJ1W-INT01
16
DC input
24 VDC
7 mA
31 mm
Latches pulses down to 50 μs pulse width M3
CJ1W-IDP01
32
DC input
24 VDC
4.1 mA
20 mm
–
1 x Fujitsu
CJ1W-ID231
32
DC input
24 VDC
4.1 mA
20 mm
–
1 x MIL*1 (40 pt)
CJ1W-ID232
32
DC input
24 VDC
4.1 mA
20 mm
Fast-response (15 μs ON, 90 μs OFF)
1 x MIL*1 (40 pt)
CJ1W-ID233
64
DC input
24 VDC
4.1 mA
31 mm
–
2 x Fujitsu
CJ1W-ID261
64
DC input
24 VDC
4.1 mA
31 mm
–
2 x MIL*1 (40 pt)
CJ1W-ID262
0.6 mA
31 mm
–
M3
CJ1W-OA201
Rated voltage
Rated current
8
Triac output
250 VAC
8
Relay output
250 VAC
2
A
31 mm
–
M3
Screwless
CJ1W-OC201
CJ1W-OC201(SL)
16
Relay output
250 VAC
2
A
31 mm
–
M3
Screwless
CJ1W-OC211
CJ1W-OC211(SL)
8
DC output (sink)
12 to 24 VDC
2
A
31 mm
–
M3
CJ1W-OD201
8
DC output (source)
24 VDC
2
A
31 mm
With short-circuit protection, alarm
M3
CJ1W-OD202
8
DC output (source)
24 VDC
0.5
A
31 mm
With short-circuit protection, alarm
M3
CJ1W-OD204
12 to 24 VDC
0.5
A
31 mm
–
M3
Screwless
CJ1W-OD211
CJ1W-OD211 (SL)
24 VDC
0.5
A
31 mm
With short-circuit protection, alarm
M3
Screwless
CJ1W-OD212
CJ1W-OD212 (SL)
16
DC output (sink)
16
DC output (source)
16
DC output (sink)
24 VDC
0.5
A
31 mm
Fast-response (15 μs ON, 80 μs OFF)
M3
CJ1W-OD213
32
DC output (sink)
12 to 24 VDC
0.5
A
20 mm
–
1 x Fujitsu
CJ1W-OD231
32
DC output (source)
24 VDC
0.3
A
20 mm
With short-circuit protection, alarm
1 x MIL*1 (40 pt)
CJ1W-OD232
32
DC output (sink)
24 VDC
0.5
A
20 mm
Fast-response (15 μs ON, 80 μs OFF)
1 x MIL*1 (40 pt)
CJ1W-OD233
64
DC output (sink)
12 to 24 VDC
0.3
A
31 mm
–
2 x Fujitsu
CJ1W-OD261
64
DC output (source)
24 VDC
0.3
A
31 mm
–
2 x MIL*1 (40 pt)
CJ1W-OD262
16 +16
DC in+out (source)
24 VDC
0.5
A
31 mm
–
2 x MIL*1 (20 pt)
CJ1W-MD232
32 +32
DC in+out (sink)
24 VDC
0.3
A
31 mm
–
2 x MIL*1 (40 pt)
CJ1W-MD263
32 +32
DC in+out (TLL)
5 VDC
35 mA
31 mm
–
2 x MIL*1 (40 pt)
CJ1W-MD563
Description
Connection type
Order code
Replacement 18-point screwless terminal blocks for I/O units, pack of 5 pcs.
Screwless
CJ-WM01-18P-5
I/O terminal block (40×M3 screw) for XW2Z-_ _ _ K
MIL (40pt)
XW2D-40G6
Connection cable between I/O terminal block and I/O unit ( _ _ _ = length in cm)
MIL (40pt)
XW2Z-_ _ _ K
*1
MIL = connector according to MIL-C-83503 (compatible with DIN 41651/IEC 60603-1).
Note: All digital I/O unit are designated as basic I/O units.
Accessories
21
CJ-Series analog I/O and control units
Modular PLC
From basic analog I/O to advanced
temperature control
The CJ-series offers a wide choice of analog input units, fit for any application, from
low-speed, multi-channel temperature measurement to high-speed, high-accuracy
data acquisition. Analog outputs can be used for accurate control or external indication.
Advanced units with built-in scaling, filtering and alarm functions reduce the need for
complex PLC programming. High-accuracy process I/O units support an extensive
range of sensors, for fast and accurate data acquisition. Temperature control units
relieve the PLC CPU of PID calculations and alarm monitoring. These functions are
handled autonomously by the unit, offering control performance and autotuning functions similar to stand-alone temperature controllers.
Ordering information
Accuracy *1
Points Type
Ranges
Resolution
4
0 to
5V
1 to
5V
0 to 10 V
0 to 20 mA
4 to 20 mA
K, J, T, L, R, S, B
Pt100, PT1000,
JPT100
V / I: 1/12000 V: 0.3%
T/C: 0.1 °C
I: 0.3%
RTD: 0.1 °C T/C: 0.3%
RTD: 0.3%
4
8
2
4
8
8
4+2
Universal analog
input
Analog input
Analog input
Analog output
Analog output
Voltage output
Current output
Analog in + output
0
0
-10
1
4
to
to
to
to
to
5 V,
10 V,
10 V,
5 V,
20 mA
1/8,000
1
0
-10
1
4
to
to
to
to
to
5 V,
10 V,
10 V,
5 V,
20 mA
1/8,000
0
0
-10
1
4
to
to
to
to
to
5 V,
10 V,
10 V,
5 V,
20 mA
1/4,000
1
0
-10
1
4
to
to
to
to
to
5 V,
10 V,
10 V,
5 V,
20 mA
1/4,000
0
0
-10
1
to
to
to
to
5 V,
10 V,
10 V,
5V
1/8,000
20 mA
1/8,000
4 to
1
0
-10
1
4
to
to
to
to
to
5 V,
10 V,
10 V,
5 V,
20 mA
1/8,000
Remarks
250 μs/point
V:
I:
0.2%
0.4%
250 μs/point
V:
I:
0.3%
0.5%
1 ms/point 31 mm Offset/gain adjustment, output hold
V:
I:
0.3%
0.5%
1 ms/point 31 mm Offset/gain adjustment, output hold
0.3%
0.5%
in: 0.2%
out: 0.3%
DC voltage,
DC current,
Thermocouple,
Pt100/Pt1000,
potentiometer
1/256000
0.05%
2
Process input
4
0
0
-10
0
-5
1
0
1.25
1/64,000
0.05%
Connection
type
250 ms/4 point 31 mm Universal inputs, with zero/span adjustment, M3
configurable alarms, scaling, sensor error Screwless
detection
0.2%
0.4%
Universal analog
input
22
Width
V:
I:
4
to 20 mA
to 20 mA
to 10 V,
to 10 V,
to
5 V,
to
5 V,
to
5 V,
to 1.25 V,
to 1.25 V
Conversion
time
250 μs/point
250 μs/point
Order code
CJ1W-AD04U
CJ1W-AD04U(SL)
31 mm Offset/gain adjustment, peak hold,
moving average, alarms
M3
CJ1W-AD041-V1
Screwless
CJ1W-AD041-V1 (SL)
31 mm Offset/gain adjustment, peak hold,
moving average, alarms
M3
CJ1W-AD081-V1
Screwless
CJ1W-AD081-V1 (SL)
M3
CJ1W-DA021
Screwless
CJ1W-DA021 (SL)
M3
CJ1W-DA041
Screwless
CJ1W-DA041 (SL)
M3
CJ1W-DA08V
Screwless
CJ1W-DA08V (SL)
M3
CJ1W-DA08C
Screwless
CJ1W-DA08C (SL)
31 mm Offset/gain adjustment, output hold
31 mm Offset/gain adjustment, output hold
1 ms/point 31 mm Offset/gain adjustment, scaling, peak hold, M3
moving average, alarms, output hold
Screwless
60 ms/4 points 31 mm All inputs individually isolated, configurable M3
alarms, maintenance functions,
user-defined scaling, zero/span adjustment
5 ms/point 31 mm Configurable alarms, maintenance
functions, user-defined scaling, zero/span
adjustment, square root, totaliser
M3
CJ1W-MAD42
CJ1W-MAD42 (SL)
CJ1W-PH41U
CJ1W-PDC15
CJ-Series analog I/O and control units
2
Thermocouple
input
B, E, J, K, L, N, R, S, 1/64,000
T, U,
WRe5-26, PLII,
-100 to 100 mV
0.05%
5 ms/point 31 mm Configurable alarms, maintenance functions M3
CJ1W-PTS15
2
Resistance thermometer input
Pt50, Pt100, JPt100, 1/64,000
Ni508.4
0.05%
5 ms/point 31 mm Configurable alarms, maintenance functions M3
CJ1W-PTS16
4
Thermocouple
Input
B, J, K, L,
R, S, T
0.1°C
0.3%
62.5 ms/point 31 mm 4 configurable alarm outputs
M3
CJ1W-PTS51
4
Resistance thermometer input
Pt100, JPt100
0.1°C
0.3%
62.5 ms/point 31 mm 4 configurable alarm outputs
M3
CJ1W-PTS52
6
Thermocouple
input
K-type
(-200 to
1,300°C)
J-Type
(-100 to 850°C)
0.1°C
0.5%
40 ms/point 31 mm Basic I/O unit, setup by DIPswitches,
adjustable filtering 10/50/60 Hz
M3
CJ1W-TS561
Screwless
CJ1W-TS561 (SL)
Resistance thermometer input
Pt100
(-200 to 650°C)
Pt1000
(-200 to 650°C)
0.1°C
40 ms/point 31 mm Basic I/O unit, setup by DIPswitches,
adjustable filtering 10/50/60 Hz
M3
CJ1W-TS562
Screwless
CJ1W-TS562 (SL)
0.5%
Conversion
time
Width
Remarks
Connection
type
Order code
4
Temperature con- B, J, K, L,
trol loops, Thermo- R, S, T
couple
0.1°C
0.3%
500 ms total
31 mm 4 control outputs: PNP open
collector, 100 mA max.
M3
CJ1W-TC002
2
Temperature con- B, J, K, L,
trol loops, Thermo- R, S, T
couple
0.1°C
0.3%
500 ms total
31 mm 2 control outputs: PNP open
M3
collector, 100 mA max., 2 current transformerinputs for heater burnout detection.
CJ1W-TC004
4
Temperature con- Pt100, JPt100
trol loops, RTD
0.1°C
0.3%
500 ms total
31 mm 4 control outputs: PNP open
collector, 100 mA max.
M3
CJ1W-TC102
2
Temperature con- Pt100, JPt100
trol loops, RTD
0.1°C
0.3%
500 ms total
31 mm 2 control outputs: PNP open
M3
collector, 100 mA max., 2 current transformerinputs for heater burnout detection.
CJ1W-TC104
*1
PLC
Ranges
1
Accuracy *1
Points Type
6
Resolution
Modular PLC
Accuracy for Voltage and Current Inputs/Outputs as percentage of full scale and typical value at 25°C ambient temperature (Consult the operation manual for details)
Accuracy for Temperature Inputs/Outputs as percentage of process value and typical value at 25°C ambient temperature (Consult the operation manual for details)
Note: All Analog I/O units are designated as Special I/O units, except TS561/TS562, which are Basic I/O units (cannot be used with CP1H).
Accessories
Description
Connection
type
Order code
Replacement 18-point screwless terminal blocks for I/O units, pack of 5 pcs.
Screwless
CJ-WM01-18P-5
23
CJ-Series motion/position control units
Modular PLC
Add motion control to any CJ-Series PLC
From simple position measurement to multi-axis synchronised motion control, the
CJ-Series offers a full range of units:
• Counter units gather position information from SSI- or incremental encoders.
Actual positions are compared with internally stored target values.
• Position Control units are used for point-to-point positioning with servo drives or
stepper motors. Target data and accelleration/deceleration curves can be adjusted
on-the-fly.
• Position- and Motion Control units equipped with MECHATROLINK-II interface can
control multiple drives through a single high-speed link. Message routing through
mutliple communication layers allows the attached drives to be configured from
any point in the control network.
Ordering information
Channels/ Type
Axes
Signal type
Unit class
Width
Remarks
Connection type
Order code
2
SSI inputs (absolute
position data)
Synchronous
serial protocol
Special I/O unit
31 mm Baud rate, encoding type, data length,
etc. can be set per channel
M3 screw
CJ1W-CTS21-E
2
500 kHz Counter
24 V, line driver
Special I/O unit
31 mm 2 configurable digital inputs + outputs
1 x Fujitsu (40 pt)
CJ1W-CT021
4
100 kHz Counter
Line driver, 24 V via
terminal block
Special I/O unit
31 mm Target values trigger interrupt to CPU
1 x MIL (40 pt)
CJ1W-CTL41-E
1
DC Motor Control unit
PWM (24 V/4 A)
Special I/O unit
31 mm 4 configurable digital inputs + 50 kHz counter input 3 x Screwless
CJ1W-DCM11-E
1
Position Control unit
24 V open collector
Special I/O unit
31 mm 500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CJ1W-NC113
2
Position Control unit
24 V open collector
Special I/O unit
31 mm 500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CJ1W-NC213
4
Position Control unit
24 V open collector
Special I/O unit
31 mm 500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
2 x Fujitsu (40 pt)
CJ1W-NC413
1
Position Control unit
Line driver
Special I/O unit
31 mm 500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CJ1W-NC133
2
Position Control unit
Line driver
Special I/O unit
31 mm 500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CJ1W-NC233
4
Position Control unit
Line driver
Special I/O unit
31 mm 500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
2 x Fujitsu (40 pt)
CJ1W-NC433
16
Position
Control unit
MECHATROLINK-II
CPU bus unit
31 mm Position, speed and torque control.
Access to all drive parameters
ML-II
CJ1W-NCF71
32
Motion Control unit
MECHATROLINK-II
CPU bus unit
80 mm Electronic CAM profiles and axis
synchronisation. Registration inputs.
Access to all drive parameters.
ML-II
CJ1W-MCH71
30
Advanced Motion Control MECHATROLINK-II,
unit
Encoder I/O, digital I/O
CPU bus unit
49 mm Trajexia Motion Controller on the CJ-series, see
page 75
ML-II, 9-pin D-Sub,
screwless push-in
CJ1W-MCH72
Description
Connection type
Order code
General purpose I/O terminal block (40×M3 screw)
MIL (40 pt)
XW2D-40G6
Screwless terminal block for connecting 24 V or Line driver encoders to CJ1W-CTL41-E
MIL (40 pt.) to 32 pt.
screwless clamp
XW2G-40G7-E
Servo interface block for 2- or 4-Axis position control unit (without communications support)
–
XW2B-40J6-2B
Servo interface block for 2- or 4-Axis position control unit (with communications support)
–
XW2B-40J6-4A
General purpose I/O connection cable for I/O units with 40-pt. Fujitsu connector ( _ _ _ = length in cm)
Fujitsu (40 pt.) to
MIL (40 pt.)
XW2Z-_ _ _ B
General purpose I/O connection cable for I/O units with 40-pt. MIL connector ( _ _ _ = length in cm)
2 x MIL (40 pt)
XW2Z-_ _ _ K
Cable connecting CJ1W-NC113 to W Series, cable length: 1.0 m
–
XW2Z-100J-A14
Cable connecting CJ1W-NC213/413 to W series, cable length: 1.0 m
–
XW2Z-100J-A15
Cable connecting CJ1W-NC113 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A16
Cable connecting CJ1W-NC213/413 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A17
Cable connecting CJ1W-NC133 to W series, cable length: 1.0 m
–
XW2Z-100J-A18
Cable connecting CJ1W-NC233/433 to W series, cable length: 1.0 m
–
XW2Z-100J-A19
Cable connecting CJ1W-NC133 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A20
Cable connecting CJ1W-NC233/433 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A21
Accessories
24
CJ-Series communication units
Modular PLC
Open to any communication
Ordering information
Type
Ports
Protocols
Unit class
Width
Connection type
Order code
Serial
2 x RS-232C
CompoWay/F, Host link, NT link, Modbus, User-defined
CPU bus unit
31 mm
9-pin D-Sub
CJ1W-SCU21-V1
Serial
2 x RS-422A/RS-485
CompoWay/F, Host link, NT link, Modbus, User-defined
CPU bus unit
31 mm
9-pin D-Sub
CJ1W-SCU31-V1
Serial
1 x RS-232C +
1 x RS-422/RS-485
CompoWay/F, Host link, NT link, Modbus, User-defined
CPU bus unit
31 mm
9-pin D-Sub
CJ1W-SCU41-V1
Ethernet
1 x 100 Base-Tx
UDP, TCP/IP, FTP server,SMTP (e-mail), SNTP (time adjust), CPU bus unit
FINS routing, socket service
31 mm
RJ45
CJ1W-ETN21
Controller link
2-wire twisted pair
Omron proprietary
CPU bus unit
31 mm
2-wire screw + GND
CJ1W-CLK21-V1
DeviceNet
1 x CAN
DeviceNet
CPU bus unit
31 mm
5-p detachable
CJ1W-DRM21
EtherNet/IP
1 x 100 Base-Tx
EtherNet/IP, UDP, TCP/IP, FTP server, SNTP, SNMP
CPU Bus unit
31 mm
RJ45
CJ1W-EIP21
PROFIBUS-DP
1 x RS-485 (Master)
DP, DPV1
CPU bus unit
31 mm
9-pin D-Sub
CJ1W-PRM21
PROFIBUS-DP
1 x RS-485 (Slave)
DP
Special I/O unit
31 mm
9-pin D-Sub
CJ1W-PRT21
PROFINET-IO
1 x 100 Base-Tx
PROFINET-IO Controller, FINS/UDP
CPU Bus unit
31 mm
RJ45
CJ1W-PNT21
CAN
1 x CAN
User-defined, supports 11-bit and 29-bit identifiers
CPU bus unit
31 mm
5-p detachable
CJ1W-CORT21
CompoNet
4-wire, data +
power to slaves (Master)
CompoNet (CIP-based)
Special I/O unit
31 mm
4-p detachable IDC or screw
CJ1W-CRM21
CompoBus/S
2-wire (Master)
Omron proprietary
Special I/O unit
20 mm
2-wire screw + 2-wire power CJ1W-SRM21
Accessories
Description
Connection type
Order code
RS-232C to RS-422/RS-485 signal converter. Mounts directly on serial port.
9-pin D-sub to screw clamp
terminals
CJ1W-CIF11
Controller link PCI board with support software
PCI, wired CLK
3G8F7-CLK21-EV1
Controller link repeater unit (wire to wire)
Screw - Screw
CS1W-RPT01
Controller link repeater unit (wire to HPCF fiber)
Screw - HPCF
connector
CS1W-RPT02
Controller link repeater unit (wire to graded-index glass fiber)
Screw - ST connector
CS1W-RPT03
25
1
Omron supports the 2 major field networks, DeviceNet and PROFIBUS-DP.
For high-speed field I/O, Omron's own CompoBus/S offers an unsurpassed ease of
installation. Fully user-configurable serial and CAN-based communication can be
used to emulate a variety of application-specific protocols. EtherNet/IP units provide
data link functions to share large amounts of data between PLCs. The new PROFINETIO controller together with the SmartSlice modular I/O system offers ethernet-based
I/O with controller- and network redundancy.
PLC
The CJ-Series offers both standardised open networks interfaces, and cost-efficient
high-speed proprietary network links. Datalinks between PLCs, or to higher-level information systems can be made using serial or Ethernet links, or the easy-to-use
controller link network.
CS-Series CPU units
Rack PLC
Fast and powerful CPUs for any task
Omron's CS1-series CPUs are available in two processor speeds, each in various
memory capacities. Besides the basic CPU models, versions are available for dualredundant operation, supporting I/O hot-swapping. All CPUs have one dedicated
board slot with a direct CPU-bus connection, in which a serial communication board
or a loop control board can be mounted. All CPU units support IEC61131-3 structured
text and ladder language.
Omron's extensive function block library helps to reduce your programming effort,
while you can create your own function blocks to suit your specific needs.
Ordering information
Max. Digital I/O Program
points
capacity
Data memory
capacity
Logic execution
speed
Max. I/O units
Additional functions
Order code
5120
448 kWords
20 ns
80
–
CS1H-CPU67H
71
Supports duplex power supply and I/O hot-swapping
CS1D-CPU67S
68
CPU for full dual-redundancy
CS1D-CPU67H
CPU for full dual-redundancy, with loop control board
CS1D-CPU67P
250 kSteps
120 kSteps
256 kWords
80
–
CS1H-CPU66H
60 kSteps
128 kWords
80
–
CS1H-CPU65H
71
Supports duplex power supply and I/O hot-swapping
CS1D-CPU65S
68
CPU for full dual-redundancy
CS1D-CPU65H
CPU for full dual-redundancy, with loop control board
CS1D-CPU65P
–
CS1H-CPU64H
–
CS1H-CPU63H
–
CS1G-CPU45H
40
–
CS1G-CPU44H
35
Supports duplex power supply and I/O hot-swapping
CS1D-CPU44S
30
–
CS1G-CPU43H
–
CS1G-CPU42H
Supports duplex power supply and I/O hot-swapping
CS1D-CPU42S
Description
Remarks
Order code
Duplex unit, required for CS1D-CPU6_H systems
–
CS1D-DPL01
Serial communication option board, 2 x RS-232C
–
CS1W-SCB21-V1
Serial communication option board, 1 x RS-232C + 1 x RS422/RS-485
–
CS1W-SCB41-V1
Loop control option board
50 control blocks max.
CS1W-LCB01
Loop control option board
300 control blocks max.
CS1W-LCB05
Replacement battery set, for all CS1 CPUs
–
CS1W-BAT01
30 kSteps
64 kWords
80
20 kSteps
60 kSteps
1280
960
40 ns
30 kSteps
20 kSteps
10 kSteps
26
Accessories
Industrial grade CompactFlash memory card, 128 MB, for all models (not required for operation) –
HMC-EF183
CompactFlash PC-Card adapter
HMC-AP001
–
CX-One, integrated software for programming and configuration of all Omron control system com- –
ponents
CX-ONE-AL_ _ C-E
Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port
length: 2.0 m
CS1W-CN226
Connection cable, D-Sub 9-pin PC serial port to PLC peripheral port
length: 6.0 m
CS1W-CN626
USB to serial conversion cable
–
CS1W-CIF31
26
CS-Series power supplies, backplanes
Rack PLC
Expand with up to 7 racks
1
PLC racks are available in several sizes, from 2 to 10 slots wide. Special backplanes
are required for duplex systems. Depending on the CPU type, up to 7 expansions can
be connected to the CPU rack, giving a total capacity of 80 I/O units. The total length
of the expansion cables of one system may be up to 12 m.
PLC
CS1 systems can operate on 24 VDC power supply, or on 100-240 VAC mains. For
small-scale systems with mainly digital I/O a low-cost small-capacity power supply
can be used. For systems with many analog I/Os and control/communication units, it
may be necessary to use a larger power supply unit.
Ordering information
Power supplies
Input range
Power
consumption
19.2 to 28.8 VDC
40 W max.
55 VA max.
85 to 264 VAC
50/60 Hz
120 VA max.
Output capacity
5 VDC
Output capacity 26
VDC
Max. output
power
Extra functions
Order code
6.6 A
0.62 A
30 W
–
C200HW-PD024
4.3 A
0.56 A
28 W
Power supply for dual-redundant system
CS1D-PD024
5.3 A
1.3 A
40 W
–
C200HW-PD025
Power supply for dual-redundant system
CS1D-PD025
Maintenance status display
C200HW-PA204C
–
C200HW-PA204
Service output 24 VDC, 0.8 A
C200HW-PA204S
Run status output (SPST relay)
C200HW-PA204R
4.6 A
0.62 A
30 W
85 to 132 VAC,
170 to 264 VAC,
50/60 Hz
180 VA max.
9.0 A
1.3 A
45 W
Run status output (SPST relay)
C200HW-PA209R
150 VA max.
7.0 A
1.3 A
35 W
Power supply for dual-redundant system
CS1D-PA207R
Type
Slots
Expansion connector Width
Special functions
Order code
CPU backplane
2
No
200 mm
–
CS1W-BC023
CPU backplane
3
Yes
260 mm
–
CS1W-BC033
CPU backplane
5
Yes
330 mm
–
CS1W-BC053
CPU backplane
8
Yes
435 mm
–
CS1W-BC083
CPU backplane
10
Yes
505 mm
–
CS1W-BC103
Expansion backplane
3
Yes
260 mm
–
CS1W-BI033
Expansion backplane
5
Yes
330 mm
–
CS1W-BI053
Expansion backplane
8
Yes
435 mm
–
CS1W-BI083
Expansion backplane
10
Yes
505 mm
–
CS1W-BI103
CPU backplane
5
Yes
505 mm
For Duplex CPU + Power supplies
CS1D-BC052
CPU backplane
8
Yes
505 mm
For Duplex Power supplies
CS1D-BC082S
Expansion backplane
9
Yes
505 mm
For Duplex Power supplies
CS1D-BI092
Type
Remarks
Specifications
I/O Expansion cable to connect
CS1 CPU backplane or
Expansion backplane to next
Expansion backplane.
Order code
0.3 m
CS1W-CN313
0.7 m
CS1W-CN713
2.0 m
CS1W-CN223
3.0 m
CS1W-CN323
5.0 m
CS1W-CN523
10.0 m
CS1W-CN133
12.0 m
CS1W-CN133-B2
27
CS-Series digital I/O units
Rack PLC
Up to 96 I/O points per unit –
input, output or mixed
Digital I/O units serve as the PLC's interface to achieve fast, reliable sequence
control. A full range of units, from high-speed DC inputs to relay outputs, let you adapt
CS1 to your needs.
CS1 units are available with various I/O densities and connection technologies.
Up to 16 I/O points can be wired to units with detachable M3 screw terminals directly.
High-density 32- and 64- point I/O units are equipped with standard 40-pin connectors. Prefabricated cables and wiring terminals are available for easy interfacing
to high-density I/O units.
Ordering information
Connection type
Order code *1
10 mA –
M3
CS1W-IA111
10 mA –
M3
CS1W-IA211
24 VDC
7 mA –
M3
CS1W-ID211
DC input
24 VDC
7 mA Inputs start interrupt tasks in PLC program
M3
CS1W-INT01
16
DC input
24 VDC
7 mA Latches pulses down to 50 μs pulse width
M3
CS1W-IDP01
32
DC input
24 VDC
6 mA –
1×40 pt Fujitsu
CS1W-ID231
64
DC input
24 VDC
6 mA –
2×40 pt Fujitsu
CS1W-ID261
96
DC input
24 VDC
5 mA –
2×56 pt Fujitsu
CS1W-ID291
8
Triac output
250 VAC
1.2 A –
M3
CS1W-OA201
16
Triac output
250 VAC
0.5 A –
M3
CS1W-OA211
8
Relay output
250 VAC
2.0 A –
M3
CS1W-OC201
16
Relay output
250 VAC
2.0 A –
M3
CS1W-OC211
16
DC output (sink)
12 to 24 VDC
0.5 A –
M3
CS1W-OD211
16
DC output (source)
0.5 A With short-circuit protection, alarm
M3
CS1W-OD212
32
DC output (sink)
0.5 A –
1×40 pt Fujitsu
CS1W-OD231
32
DC output (source)
0.5 A With short-circuit protection, alarm
1×40 pt Fujitsu
CS1W-OD232
64
DC output (sink)
0.3 A –
2×40 pt Fujitsu
CS1W-OD261
64
DC output (source)
0.3 A With short-circuit protection, alarm
2×40 pt Fujitsu
CS1W-OD262
96
DC output (sink)
12 to 24 VDC
0.1 A –
2×56 pt Fujitsu
CS1W-OD291
96
DC output (source)
24 VDC
0.1 A –
2×56 pt Fujitsu
CS1W-OD292
32+32
DC output (sink)
12 to 24 VDC
0.3 A –
2×40 pt Fujitsu
CS1W-MD261
32+32
DC in+out (source)
0.3 A With short-circuit protection, alarm
2×40 pt Fujitsu
CS1W-MD262
48+48
DC output (sink)
12 to 24 VDC
0.1 A –
2×56 pt Fujitsu
CS1W-MD291
48+48
DC in+out (source)
12 to 24 VDC
0.1 A –
2×56 pt Fujitsu
CS1W-MD292
Points
Type
16
AC or DC input
120 VAC or VDC
16
AC input
240 VAC
16
DC input
16
*1
Rated voltage
24 VDC
12 to 24 VDC
24 VDC
12 to 24 VDC
24 VDC
24 VDC
C200H I/O units can also be mounted, except on CS1D systems.
Note: All Digital I/O units are designated as Basic I/O units.
28
Rated
current
Remarks
CS-Series analog and process I/O units
Rack PLC
From basic analog I/O to process control
1
Advanced units with built-in scaling, filtering and alarm functions reduce the need for
complex PLC programming. High-accuracy process I/O units support an extensive
range of sensors, for fast and accurate data acquisition. All process and temperature
I/O units provide isolation between all individual channels.
PLC
CS1 offers a wide choice of analog input units, fit for any application, from low-speed,
multi-channel temperature measurement to high-speed, high-accuracy data acquisition. Analog outputs can be used for accurate control or external indication.
Ordering information
Points
Type
4
Analog input
8
Analog input
18
Analog input
4
Ranges
Resolution
Accuracy*1
V:
I:
0 to
0 to
-10 to
1 to
4 to
5 V,
10 V,
10 V,
5 V,
20 mA
1/8,000
Analog output
0 to
0 to
-10 to
1 to
4 to
5 V,
10 V,
10 V,
5 V,
20 mA
1/4,000
8
Voltage output
0 to
0 to
-10 to
1 to
5 V,
10 V,
10 V,
5V
8
Current output
4 to
4+4
Analog in + output
0 to
5 V,
0 to
10 V,
-10 to
10 V,
1 to
5V
(4 to 20 mA input)
1/8,000
4
Process input
4 to
20 mA,
0 to
20 mA,
0 to
10 V,
-10 to
10 V,
0 to
5 V,
-5 to
5 V,
1 to
5 V,
1 to 1.25 V,
-1.25 to 1.25 V
8
Process input
4
Thermocouple input
4
Resistance thermometer input Pt50, Pt100 JPt100,
Ni508.4
1/64,000
4
Thermocouple input
4
Resistance thermometer input Pt100, JPt100
8
Thermocouple input
8
0.2% of PV
0.4% of PV
Conversion
time
250 μs/point
Remarks
Connection
type
Order code
Offset/gain adjustment, peak hold,
moving average, alarms
M3
CS1W-AD041-V1
M3
CS1W-AD081-V1
0.2% of PV
V:
I:
0.3% of PV
0.5% of PV
2 x MIL (34p.) CS1W-AD161
1 ms/point
0.3% of PV
20 mA
Offset/gain adjustment
M3
CS1W-DA041
Offset/gain adjustment, output hold
M3
CS1W-DA08V
M3
CS1W-DA08C
0.5% of PV
V in: 0.2% of PV
I in: 0.4% of PV
out: 0.3% of PV
1 ms/point
Offset/gain adjustment, scaling, peak
hold, moving average, alarms, output
hold
M3
CS1W-MAD44
1/64,000
0.05% of PV
5 ms/point
Configurable alarms, maintenance
M3
functions, user-defined scaling, zero/
span adjustment, square root, totaliser.
CS1W-PDC11
1/16,000
0.3% of PV
62.5 ms/point
Configurable alarms, zero/span adjust- M3
ment, square root
CS1W-PDC55
B, E, J, K, L, N, R, S, T, 1/64,000
U, WRe5-26, PLII,
-100 to 100 mV
0.05% of PV
5 ms/point
Configurable alarms (absolute +
rate-of-change), peak hold,
maintenance functions
M3
CS1W-PTS11
0.05% of PV
5 ms/point
Configurable alarms (absolute +
rate-of-change), peak hold,
maintenance functions
M3
CS1W-PTS12
0.1°C
0.3% of PV
62.5 ms/point
4 configurable alarm outputs
M3
CS1W-PTS51
0.1°C
0.3% of PV
62.5 ms/point
4 configurable alarm outputs
M3
CS1W-PTS52
0.1°C
0.3% of PV
31.2 ms/point
Configurable alarms per channel
M3
CS1W-PTS55
Resistance thermometer input Pt100, JPt100
0.1°C
0.3% of PV
31.2 ms/point
Configurable alarms per channel
M3
CS1W-PTS56
4
2-Wire transmitter input
1 to
4 to
5 V,
20 mA
1/4,096
0.2% of FS
25 ms/point
Built-in power supply for transmitter,
configurable alarms, square root,
rate-of-change, etc.
M3
CS1W-PTW01
8
Power transducer input
-1 to
0 to
1 mA,
1 mA
1/4,096
0.2% of FS
25 ms/point
Inrush current limiter, configurable
alarms, averaging, etc.
M3
CS1W-PTR01
8
Power transducer input
-100 to
0 to
100 mV,
100 mV
1/4,096
0.2% of FS
25 ms/point
Inrush current limiter, configurable
alarms, averaging, etc.
M3
CS1W-PTR02
4
Pulse rate input
25 ms/point
Averaging, totaliser
M3
CS1W-PPS01
-10 to
0 to
1 to
4 to
10 V,
5 V,
5 V,
20 mA
B, J, K, L, R, S, T
B, J, K, L, R,S, T
20000 pps, voltage,
up to
open collector, contact 1/32,000
–
29
CS-Series analog and process I/O units
Points
Type
4
Isolated control output
1 to
4 to
4
Isolated control output
-10 to
0 to
-5 to
0 to
-1 to
0 to
*1
Resolution
Accuracy*1
5 V,
20 mA
1/4,000
I:
V:
10 V,
10 V,
5 V,
5 V,
1 V,
1V
1/4,000
Ranges
Remarks
Connection
type
Order code
0.1% of FS
0.2% of FS
25 ms/point
Output readback, high/low/rate limiting, M3
disconnection alarm, zero/span
adjustment
CS1W-PMV01
0.1% of FS
10 ms/point
High/low/rate limiting, output hold,
zero/span adjustment
CS1W-PMV02
M3
Accuracy for Voltage and Current Inputs/Outputs as percentage of full scale and typical value at 25°C ambient temperature (Consult the operation manual for details)
Accuracy for Temperature Inputs/Outputs as percentage of process value and typical value at 25°C ambient temperature (Consult the operation manual for details)
Note: All analog I/O units are designated as special I/O units
30
Conversion
time
Rack PLC
CS-Series position/motion control units
Rack PLC
Add motion control to any CS1 PLC
Ordering information
Channels/
Axes
Type
Signal type
Unit class
Remarks
Connection type
Order code
2
SSI inputs
(absolute position data)
Synchronous
serial protocol
Special I/O unit
Baud rate, encoding type, data length,
etc. can be set per channel
2 digital outputs, NPN/PNP selectable.
M3 screw
CS1W-CTS21
2
500 kHz Counter
24 V, 12V, line driver
Special I/O unit
4 configurable digital inputs +
4 configurable digital outputs
Target values trigger interrupt to CPU
1 x Fujitsu (40 pt)
CS1W-CT021
2 x Fujitsu (40 pt)
CS1W-CT041
4
1
Position control unit
24V open collector
Special I/O unit
500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CS1W-NC113
2
Position control unit
24V open collector
Special I/O unit
500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CS1W-NC213
4
Position control unit
24V open collector
Special I/O unit
500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
2 x Fujitsu (40 pt)
CS1W-NC413
1
Position control unit
Line driver
Special I/O unit
500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CS1W-NC133
2
Position control unit
Line driver
Special I/O unit
500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
1 x Fujitsu (40 pt)
CS1W-NC233
4
Position control unit
Line driver
Special I/O unit
500 kpps pulse outputs, inputs for origin,
limit switches, stop, interrupt
2 x Fujitsu (40 pt)
CS1W-NC433
2
Motion control unit
Analog
Special I/O unit
Closed loop with automatic trapezoid or
S-curve acceleration/deceleration
Snap-on connectors (3M)
CS1W-MC221-V1
4
Motion control unit
Analog
Special I/O unit
Closed loop with automatic trapezoid or
S-curve acceleration/deceleration
Snap-on connectors (3M)
CS1W-MC421-V1
32
Motion control unit
MECHATROLINK-II
CPU bus unit
Electronic cam profiles and axis
synchronisation. Registration inputs.
Access to all drive parameters.
ML-II
CS1W-MCH71
Description
Connection type
Order code
General purpose I/O terminal block (40×M3 screw)
MIL (40 pt)
XW2D-40G6
General purpose I/O connection cable for I/O units with 40-pt. Fujitsu connector ( _ _ _ = length in cm)
Fujitsu (40 pt.) to
MIL (40 pt.)
XW2Z-_ _ _ B
Servo interface block for 2- or 4-Axis position control unit (without communications support)
–
XW2B-40J6-2B
Servo interface block for 2- or 4-Axis position control unit (with communications support)
–
XW2B-40J6-4A
Cable connecting CS1W-NC113 to W Series, cable length: 1.0 m
–
XW2Z-100J-A14
Cable connecting CS1W-NC213/413 to W Series, cable length: 1.0 m
–
XW2Z-100J-A15
Cable connecting CS1W-NC113 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A16
Cable connecting CS1W-NC213/413 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A17
Cable connecting CS1W-NC133 to W Series, cable length: 1.0 m
–
XW2Z-100J-A18
Cable connecting CS1W-NC233/433 to W series, cable length: 1.0 m
–
XW2Z-100J-A19
Cable connecting CS1W-NC133 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A20
Cable connecting CS1W-NC233/433 to SmartStep, cable length: 1.0 m
–
XW2Z-100J-A21
Accessories
31
1
• Counter units gather position information from SSI- or incremental encoders.
Actual positions are compared with internally stored target values.
• Position control units are used for point-to-point positioning with servo drives or
stepper motors. Target data and acceleration/deceleration curves can be adjusted
on-the-fly.
• Position- and motion control units equipped with MECHATROLINK-II interface can
control multiple drives through a single high-speed link. Message routing through
mutliple communication layers allows the attached drives to be configured from
any point in the control network.
PLC
From simple position measurement to multi-axis synchronised motion control, CS1
offers a full range of units:
CS-Series communication units
Rack PLC
Open to any communication, standard or
user-defined
CS1 provides both standardised open networks interfaces, and cost-efficient highspeed proprietary network links. Datalinks between PLCs, or to higher-level information systems can be made using Serial or Ethernet links, or the easy-to-use Controller
Link network.
Omron supports the 2 major field networks, DeviceNet and PROFIBUS-DP.
For high-speed field I/O, Omron's own CompoBus/S offers an unsurpassed ease of
installation. Fully user-configurable serial and CAN-based communication can be
used to emulate a variety of application-specific protocols.
Ordering information
Type
Ports
Protocols
Remarks
Connection type
Order code
Serial
2 x RS-232C
CompoWay/F, Host Link, NT link, Modbus, CPU bus unit
User-defined
Unit class
–
9-pin D-Sub
CS1W-SCU21-V1
Serial
2 x RS-232C/RS-485
CompoWay/F, Host Link, NT link, Modbus, CPU bus unit
User-defined
–
9-pin D-Sub
CS1W-SCU31-V1
Serial
2 x RS-232C
CompoWay/F, Host Link, NT link, Modbus, CPU option board
User-defined
–
9-pin D-Sub
CS1W-SCB21-V1
Serial
1 x RS-232C +
1 x RS-422/RS-485
CompoWay/F, Host Link, NT link, Modbus, CPU option board
User-defined
–
9-pin D-Sub
CS1W-SCB41-V1
GP-IB
Master/Slave selectable
GP-IB instrument
communication
Special I/O unit
–
GP-IB
CS1W-GPI01
Ethernet
1 x 100 Base-Tx
UDP, TCP/IP, FTP server,
SMTP (e-mail), SNTP (time adjust),
FINS routing, socket service
CPU bus unit
–
RJ45
CS1W-ETN21
Controller link
2-wire twisted pair
Omron proprietary
CPU bus unit
–
2-wire screw + GND
CS1W-CLK21-V1
Optical HPCF
–
2 x HPCF connector
CS1W-CLK12-V1
Optical graded-index fiber
–
4 x ST connector
CS1W-CLK52-V1
EtherNet/IP
1 x 100 Base-Tx
EtherNet/IP, UDP, TCP/IP, FTP server,
SNTP, SNMP
CPU Bus unit
31 mm
RJ45
CS1W-EIP21
DeviceNet
1 x CAN
DeviceNet
CPU bus unit
–
5-p detachable
CS1W-DRM21-V1
CompoNet
4-wire, data + power to slaves CompoNet (CIP-based)
(Master)
Special I/O unit
–
4-p detachable IDC
or screw
CS1W-CRM21
PROFIBUS-DP
1 x RS-485 (Master)
DP, DPV1
CPU bus unit
–
9-pin D-Sub
CS1W-PRM21
CAN
1 x CAN
CANopen, User-defined
CPU bus unit
–
5-p detachable
CS1W-CORT21
PROFIBUS-DP
1 x RS-485 (Slave)
DP
C200H special
I/O unit
C200H units cannot be
used on CS1D systems
9-pin D-Sub
C200HW-PRT21
CompoBus/S
2-wire (Master)
Omron proprietary
C200H special
I/O unit
2-wire screw +
2-wire power
C200HW-SRM21-V1
Description
Connection type
Order code
RS-232C to RS-422/RS-485 signal converter. Mounts directly on serial port.
9-pin D-sub to screw clamp CJ1W-CIF11
terminals
Controller link PCI board with support software
PCI, wired CLK
3G8F7-CLK21-EV1
Controller link PCI board with support software
PCI, HPCF connectors
3G8F7-CLK12-EV1
Controller link PCI board with support software
PCI, ST connectors
3G8F7-CLK52-EV1
Controller link repeater unit (wire to wire)
Screw - Screw
CS1W-RPT01
Controller link repeater unit (wire to HPCF fiber)
Screw - HPCF connector
CS1W-RPT02
Controller link repeater unit (wire to graded-index glass fiber)
Screw - ST connector
CS1W-RPT03
Accessories
32
WE70
Rack PLC
FA Wireless LAN unit
WE70 utilises spread-spectrum modulation technology based on radio waves to enable communication between devices in a limited areaThis gives users the mobility
to move around within a broad coverage area and still be connected to the network.
The smart roaming function enables high speed roaming therefore moving equipment
and mobile object can communicate at high speed.
PLC
Conforms to IEEE 802.11a/b/g.
Same noise and environment resistance level as a PLC.
Features OMRON'S original security system.
Signals can be observed with LED indicators.
Conforms to radio wave standards for the USA, Europe, and China.
1
•
•
•
•
•
Ordering information
Area
Type
Model
Europe
Access Point (Master)
WE70-AP-EU
Client (Slave)
WE70-CL-EU
Access Point (Master)
WE70-AP-US
Client (Slave)
WE70-CL-US
Access Point (Master)
WE70-AP-CN
Client (Slave)
WE70-CL-CN
Type
Specifications
Model
Directional Magnetic-base Antenna
1 set with two Antennas, 2.4 GHz/5 GHz Dual-band compatible
WE70-AT001H
USA
China
Accessories
Type
Model
DIN Rail Mounting Bracket (for TH35 7.5)
WT30-FT001
DIN Rail Mounting Bracket (for TH35 15)
WT30-FT002
Antenna Extension Cable (5 m)
WE70-CA5M
33
Remote I/O
THE SMARTEST MODULAR I/O SYSTEM
SmartSlice – Intelligence point by point
SmartSlice is the most advanced, yet easy-to-use remote I/O system currently available.
Its built-in intelligence will help to reduce the effort you spend on engineering, troubleshooting and
maintenance in your machine, line or plant. By keeping track of control performance and logging all
operations, each module can provide timely warnings, preventing costly machine downtime.
SmartSlice supports the open communication standards PROFINET-IO, PROFIBUS-DP, DeviceNet,
CompoNet and MECHATROLINK-II. This provides you the flexibility to adapt to local requirements,
anywhere in the world, without changing your I/O.
• Reduce engineering time
• Reduce machine downtime
• Increase your efficiency
The five most used smart features are demonstrated at:
www.smartslice.info
PROFIBUS-DP
DeviceNet
IP67
Compact
34
IP20
IP20
Compact
Wireless
Link
I/O
DRT2-_C_
WD30
WT30
DRT2
Page 42
Page 45
Page 45
Page 39
Modular
Modular
Remote I/O
2
Remote I/O
PROFINET I/O
CompoBus/S
CompoNet
IP20
IP20
IP20
IP54
IP20
IP67
Modular
Modular
Compact
Compact
Compact
Compact
SmartSlice
CRT1
CRT1B-_P_
SRT2
SRT2-_C_
Page 38
Page 40
Page 43
Page 41
Page 44
35
Selection table
Modular I/O
Model
Compact I/O
GRT
Network connection DeviceNet open-style terminal block
PROFIBUS-DP 9-pin D-sub
CompoNet: 4-pin system connector
PROFINET-IO: 2 x RJ45
DRT2
CRT1
SRT2
DeviceNet with open-style push-in
terminal block
Unshielded 4-wire flat cable and
IDC connectors, or general-purpose
2-wire cable by screw terminals.
CompoBus/S, (2-wire + power)
by M3 screw terminals
8/16 DI+extension,
8/16 DO+extenstion,
16 relay out,
4 AI (V/I, TC, Pt100),
2 AO (V/I),
16 DI+extension,
16 DO+extenstion,
4 AI, 2 AO, 2 DI, 2 DO.
4/8/16 DI,
4/8/16 DO,
8/16 relay out,
4 AI (V/I) 2 AO (V/I)
M3 screw terminals (1 or 3-wire DI)
M3 screw terminals,
eCON/RITS sensor connectors
M3 screw terminals (1 or 3-wire DI)
Smart features I/O and power supply diagnostics.
Operation timers and counters per
I/O point. Analog value calculations
and alarms.
I/O and power supply diagnostics.
Operation timers and counters per
I/O point. Analog value calculations
and alarms.
I/O and power supply diagnostics.
Operation timers and counters
for each I/O point. Analog value
calculations and alarms.
I/O isolation, status indication
Ingress Protection class IP20 (DIN rail mounting in cabinets)
IP20 (DIN rail mounting in cabinets)
IP20 (DIN rail mounting in cabinets)
IP20 (DIN rail mounting in cabinets)
main units: 50×115/125×50;
8/16 pt. expansion: 50×66/94×50
main units: 50×115×50;
8/16 pt. expansion: 50×66/94×50;
2-point slaves: 50×50×30
DI/DO units : 50×80/105/180×48;
Relay units: 50×100/155×50;
analog units : 50×105×48
39
40
41
MECHATROLINK-II: 2 x ML-II
I/0 types 2/4/8-point digital I/O
2-point analog I/O
2-point temperature input
Counter units
Power feed units
Expansion units
I/0 Connection technology Push-in screwless clamp
Size in mm (H×W×D) Bus coupler: 84×58×70
I/O units: 84×15×74
Page 38
36
Remote I/0
Model
DRT2-_C_
CRT1B-_P_
SRT2-_C_
WD30/WT30
Unshielded 4-wire flat cable and
IP54-rated IDC connectors
CompoBus/S, by 4-wire M12
connector, unshielded
DeviceNet M12 connection
RS-232C by 9-pin D-sub
2/4 DI, 2 DO, 2DI + 2DO
4/8 DI, 4/8 DO
Wireless link, 16 DI, 8DI + 8DO
eCON/RITS sensor connectors,
screwless clamp connection
M12 connectors,
one I/O point per connector
Push-in screwless clamp
I/O and power supply diagnostics.
Operation timers and counters per I/O
point.
I/O isolation, status indication
Wireless link diagnostics
Explicit message communication
IP54,
flat mounting by two M5 screws
IP67,
flat mounting by three M5 screws
IP20 (cabinet mounting).
Separate antennas (IP67) can be
mounted outside the cabinet
90×50×50
114/160×54×29.5
WD30: 80x95x35
WT30: 105x90x40
43
44
45
2
Network connection DeviceNet with M12 micro
connector
Wireless I/O
Remote I/0
Field I/0
I/0 types 8/16 DI, 8/16 DO, 8DI + 8 DO
I/0 Connection technology M12, 1 or 2 I/O signals per connector.
7/8” I/O Power connector.
Smart features I/O and power supply diagnostics.
Operation timers and counters per I/O
point.
Ingress Protection class IP67,
flat mounting by two M5 screws
Size in mm (H×W×D) 175×60×27.3
Page 42
37
SmartSlice I/O system
Remote I/O
The smartest modular I/O system
Omron's SmartSlice I/O system is compact, intelligent and easy. When used
with Omron's CS1/CJ1 DeviceNet master units it is plug-and-work, no configuration
tool is required. By using built-in functions such as pre-scaling, totalising, differentiation and alarming in analog I/O units, PLC programming can be minimised. Preventive maintenance data can be accessed using CX-Integrator software, standard PLC
function blocks or NS-series Smart Active Parts.
•
•
•
•
•
Most compact in the market (84 mm high)
Easy set-up, backup and restore functions
Diagnostics and preventive maintenance data at I/O level
Detachable terminal blocks allow hot-swapping without re-wiring
3-wire connection with 'push-in' technology, no screwdriver
required for installation
Ordering information
Model
Function
Specifications
Size in mm
(HxWxD)
Order code
Interface units
DeviceNet interface unit
For up to 64 I/O units
84x58x70
GRT1-DRT
CompoNet interface unit
For up to 64 I/O units (limited to 32 byte in + 32 byte out)
84x58x70
GRT1-CRT*1
PROFIBUS-DP interface unit
For up to 64 I/O units
84x58x70
GRT1-PRT
PROFINET-IO interface unit
For up to 64 I/O units
84x58x70
GRT1-PNT*1
MECHATROLINK-II interface unit
For up to 64 I/O units (slave to Trajexia motion controller)
84x58x70
GRT1-ML2
End plate
One unit required per bus interface
84x20x58
GRT1-END
End plate with memory function
Supports toolless replacement of PROFINET-IO interface unit
84x20x58
GRT1-END-M*1
4 NPN inputs
24 VDC, 6 mA, 3-wire connection
84x15x74
GRT1-ID4
4 PNP inputs
24 VDC, 6 mA, 3-wire connection
84x15x74
GRT1-ID4-1
8 NPN inputs
24 VDC, 4 mA, 1-wire connection + 4xG
84x15x74
GRT1-ID8
8 PNP inputs
24 VDC, 4 mA, 1-wire connection + 4xV
84x15x74
GRT1-ID8-1
4 AC inputs
110 VAC, 2-wire connection
84x15x74
GRT1-IA4-1
4 AC inputs
230 VAC, 2-wire connection
84x15x74
GRT1-IA4-2
4 NPN outputs
24 VDC, 500 mA, 2-wire connection
84x15x74
GRT1-OD4
4 PNP outputs
24 VDC, 500 mA, 2-wire connection
84x15x74
GRT1-OD4-1
4 PNP outputs with short-circuit protection 24 VDC, 500 mA, 3-wire connection
84x15x74
GRT1-OD4G-1
4 PNP outputs with short-circuit protection 24 VDC, 2 A, 2-wire connection
84x15x74
GRT1-OD4G-3
8 NPN outputs
24 VDC, 500 mA, 1-wire connection + 4xV
84x15x74
GRT1-OD8
8 PNP outputs
24 VDC, 500 mA, 1-wire connection + 4xG
84x15x74
GRT1-OD8-1
8 PNP outputs with short-circuit protection 24 VDC, 500 mA, 1-wire connection + 4xG
84x15x74
GRT1-OD8G-1
2 relay outputs
240 VAC, 2A, normally-open contacts
84x15x74
GRT1-ROS2
60 kHz Counter unit, NPN
A+B encoder inputs + 1 Z/control input + 1 output (NPN-type)
84x15x74
GRT1-CT1
60 kHz Counter unit, PNP
A+B encoder inputs + 1 Z/control input + 1 output (PNP-type)
84x15x74
GRT1-CT1-1
100 kHz Counter / Positioner unit
A+B+Z encoder inputs (line driver or 24 V selectable) + 1 control input + 2 outputs (PNP-type) 84x15x74
GRT1-CP1-L
2 analog inputs, current/voltage
±10 V, 0-10 V, 0-5 V, 1-5 V, 0-20 mA, 4-20 mA
84x15x74
GRT1-AD2
2 analog outputs, voltage
±10 V, 0-10 V, 0-5 V, 1-5 V
84x15x74
GRT1-DA2V
2 analog outputs, current
0-20 mA, 4-20 mA
84x15x74
GRT1-DA2C
2 Pt100 inputs
Pt100, 2-wire or 3-wire connection
84x15x74
GRT1-TS2P
2 Pt1000 inputs
Pt1000, 2-wire or 3-wire connection
84x15x74
GRT1-TS2PK
2 Thermocouple inputs
Types B, E, J, K, N, R, S, T, U, W, PL2, with cold junction compensation
84x15x74
GRT1-TS2T
I/O units
*1
Release Q2 2008
Model
Description
Size in mm
(HxWxD)
Order code
Other units
I/O power feed unit, separates power supply between groups of I/O units
84x15x74
GRT1-PD2
I/O power feed unit with electronic overload protection, separates power supply between groups of I/O units
84x15x74
GRT1-PD2G
I/O power feed and distribution unit, separates power supply between groups of I/O units, 8xV + 4xG
84x15x74
GRT1-PD8
I/O power feed and distribution unit, separates power supply between groups of I/O units, 4xV + 8xG
84x15x74
GRT1-PD8-1
I/O power connection unit, 8xV + 4xG
84x15x74
GRT1-PC8
I/O power connection unit, 4xV + 8xG
84x15x74
GRT1-PC8-1
Turnback unit, right-hand side
84x20x58
GRT1-TBR
Turnback unit, left-hand side
84x58x70
GRT1-TBL
Turnback cable, one meter
1m
GCN2-100
Accessories
Description
Order code
Replacement front connectors, pack of 5 pcs.
GRT1-BT1-5
PROFIBUS-DP connector, 9-pin D-sub
PROFIBUS Connector 839550
PROFIBUS-DP connector, 9-pin D-sub, with bus termination
PROFIBUS Term. Conn. 846086
38
Compact I/O DRT2
Remote I/O
Compact DeviceNet I/O units with extensive diagnostic functions. Data regarding
power supply status, I/O response times, operation counters and on-time are
continuously recorded and checked against user-defined limits. Any deviation is
reported to the control system, as indication to perform machine maintenance and
prevent unplanned downtime. Smart DeviceNet I/Os are supported by PLC Function
Blocks and HMI Smart Active Parts, allowing program-less visualisation and
monitoring from the CJ1 PLCs and NS operator terminals.
Compact size IP20 housing
Expandable digital I/Os
Built-in diagnostics and preventive maintenance functions
Detachable I/O terminal blocks
Analog I/O with data pre-processing and alarm functions
2
•
•
•
•
•
Remote I/O
Smart DeviceNet I/O
Ordering information
Unit type
Specifications
Size in mm
(HxWxD)
Remarks
Order code
8-point PNP input unit
24 VDC, 6 mA per point
50x115x50
–
DRT2-ID08-1
16-point PNP input unit
24 VDC, 6 mA per point
50x115x50
Expandable with one XWT unit
DRT2-ID16-1
16-point PNP input unit
24 VDC, 6 mA per point
50x180x58
3-tier connection for direct sensor wiring
DRT2-ID16TA-1
8-point PNP output unit
24 VDC, 0.5 A per point
50x115x50
–
DRT2-OD08-1
16-point PNP output unit
24 VDC, 0.5 A per point
50x115x50
Expandable with one XWT unit
DRT2-OD16-1
16-point PNP output unit
24 VDC, 0.5 A per point
50x180x58
3-tier connection for direct actuator wiring
DRT2-OD16TA-1
16-point relay output unit
2 A per point, max. 8 A per common
50x125x52
with easy-to-replace relays, expandable with one XWT unit DRT2-ROS16
8-point input + 8-point output unit (PNP)
24 VDC, input 6 mA, output 0.5 A per point
50x115x50
–
DRT2-MD16-1
8-point input + 8-point output unit (PNP)
24 VDC, input 6 mA, output 0.5 A per point
50x180x58
3-tier connection for direct sensor/actuator wiring
DRT2-MD16TA-1
4-Channel analog input unit
0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA,
4 to 20 mA
50x115x50
Resolution 1/6000, conversion time 4 ms (4 inputs)
DRT2-AD04
4-Channel analog input unit
1 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA,
4 to 20 mA
50x115x50
Resolution 1/30000, conversion time 250 ms (4 inputs)
DRT2-AD04H
2-Channel analog output unit
0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V, 0 to 20 mA,
4 to 20 mA
50x115x50
Resolution 1/6000, conversion time 2 ms (2 outputs)
DRT2-DA02
2-Channel temperature input unit
Platinum Resistance Thermometer types Pt100, JPt100 50x115x50
0.3% accuracy, conversion time 250 ms (4 inputs)
DRT2-TS04P
2-Channel temperature input unit
Thermocouple types R, S, K, J, T, B, L, E, U, N, W,
and PL2
50x115x50
0.3% accuracy, conversion time 250 ms (4 inputs)
DRT2-TS04T
8-point PNP input expansion unit
24 VDC, 6 mA per point
50x66x50
Expansion unit for DRT2 and CRT1 series
XWT-ID08-1
16-point PNP input expansion unit
24 VDC, 6 mA per point
50x94x50
Expansion unit for DRT2 and CRT1 series
XWT-ID16-1
8-point PNP output expansion unit
24 VDC, 0.5 A per point
50x66x50
Expansion unit for DRT2 and CRT1 series
XWT-OD08-1
16-point PNP output expansion unit
24 VDC, 0.5 A per point
50x94x50
Expansion unit for DRT2 and CRT1 series
XWT-OD16-1
Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the "-1" from the model code.
Accessories
Type
Order code
Power supply tap with 2 fuses, 2 bus connectors and termination resistor
DCN1-1P
T-branch tap with 3 bus connectors (screw clamp) and terminating resistor
DCN1-1C
T-branch tap with 3 bus connectors (screwless)
DCN1-1NC
T-branch tap with 5 bus connectors (screw clamp) and terminating resistor
DCN1-3C
T-branch tap with 5 bus connectors (screwless)
DCN1-3NC
Terminating resistor with screw terminals
DRS1-T
39
Compact I/O CRT1
Remote I/O
Smart CompoNet I/O
Combining the smart features of DRT2 DeviceNet I/O and the speed and ease of use
of CompoBus/S, CompoNet is ideal for high-speed machine control with a flexible and
expandable architecture. The special flat cable and IDC connectors make installation
quick and easy. The use of repeaters allows wide-area networks with free topology,
ideal for conveyor- and warehouse automation.
•
•
•
•
•
Compact size IP20 housing
Expandable digital I/Os with detachable terminal blocks
Easy network wiring with IDC connections
Built-in diagnostics and preventive maintenance functions
Analog I/O with data pre-processing and alarm functions
Ordering information
Main units
Unit type
Specifications
Size in mm
(HxWxD)
Remarks
Order code
2-point PNP input unit
24 VDC, 6 mA per point
48x48x32
e-CON sensor connectors, power supply via CompoNet cable
(50 cm attached)
CRT1B-ID02S-1
8-point PNP input unit
24 VDC, 6 mA per point
50x115x57.6
Screw terminals, common power terminals per 8 points
CRT1-ID08-1
8-point PNP input unit
24 VDC, 6 mA per point
50x96x60
3 push-in terminals per I/O point (signal + power)
CRT1-ID08SL-1
16-point PNP input unit
24 VDC, 6 mA per point
50x115x50
Expandable with one XWT unit.
CRT1-ID16-1
16-point PNP input unit
24 VDC, 6 mA per point
52x180x69
3 terminals per I/O point (for power distribution)
CRT1-ID16TA-1
2-point PNP output unit
24 VDC, 0.2 A per point
48x48x32
e-CON sensor connectors, power supply via CompoNet cable
(50 cm attached)
CRT1B-OD02S-1
8-point PNP output unit
24 VDC, 0.5 A per point
50x115x57.6
Screw terminals, common power terminals per 8 points
CRT1-OD08-1
8-point PNP output unit
24 VDC, 0.5 A per point
50x96x60
3 push-in terminals per I/O point (signal + power)
CRT1-OD08SL-1
16-point PNP output unit
24 VDC, 0.5 A per point
50x115x50
Expandable with one XWT unit.
CRT1-OD16-1
16-point PNP output unit
24 VDC, 0.5 A per point
52x180x69
3 terminals per I/O point (for power distribution)
CRT1-OD16TA-1
8-point SSR output unit
265 V AC, 0.3 A per point
50x95x57.6
Screw terminals, common power terminals per 8 points
CRT1-ROF08
8-point relay output unit
250 VAC, 2 A per point, 8 A per common
50x95x57.6
Screw terminals, common power terminals per 8 points
CRT1-ROS08
16-point relay output unit
250 VAC, 2 A per point, 8 A per common
50x140x57.6
8 outputs per common
CRT1-ROS16
8-point input + 8-point output unit, PNP
24 VDC, 0.5 A per point
50x115x57.6
Screw terminals, common power terminals
CRT1-MD16-1
8-point input + 8-point output unit, PNP
24 VDC, 0.5 A per point
50x170x60
3 push-in terminals per I/O point (signal + power)
CRT1-MD16SL-1
8-point input + 8-point output unit PNP
24 VDC, 0.5 A per point
52x180x69
3 terminals per I/O point (for power distribution)
CRT1-MD16TA-1
4-Channel analog input unit
0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V,
0 to 20 mA, 4 to 20 mA
50x115x50
Resolution 1/6000, conversion time 4 ms (4 inputs)
CRT1-AD04
2-Channel analog output unit
0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V,
0 to 20 mA, 4 to 20 mA
50x115x50
Resolution 1/6000, conversion time 2 ms (2 outputs)
CRT1-DA02
Unit type
Specifications
Size in mm
(HxWxD)
Remarks
Order code
8-point PNP input expansion unit
24 VDC, 6 mA per point
50x66x50
Expansion unit for DRT2 and CRT1 series
XWT-ID08-1
16-point PNP input expansion unit
24 VDC, 6 mA per point
50x94x50
Expansion unit for DRT2 and CRT1 series
XWT-ID16-1
8-point PNP output expansion unit
24 VDC, 0.5 A per point
50x66x50
Expansion unit for DRT2 and CRT1 series
XWT-OD08-1
16-point PNP output expansion unit
24 VDC, 0.5 A per point
50x94x50
Expansion unit for DRT2 and CRT1 series
XWT-OD16-1
Expansion units
Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the "-1" from the model code.
Accessories
Unit type
Specifications
Size in mm
(HxWxD)
Remarks
Order code
CompoNet Repeater unit
1 upstream port + 1 downstream port
50x95x43
For extending CompoNet trunk lines, or creating branch lines
CRS1-RPT01
CompoNet 4-wire flat cable
For IP20 use
100 m
For power supply + communication, use with DCN4-connectors DCA4-4F10
CompoNet Branch connector for trunk line
For IP20 use
–
To create a branching point on a trunk line
DCN4-TR4
CompoNet Branch line end connector
For IP20 use
–
To connect a branch line to a trunk line
DCN4-BR4
CompoNet Y-connector
For IP20 use
–
To connect two line connectors to one slave unit
DCN4-MD4
CompoNet Screw terminal connector
For IP20 use
–
To provide conventional screw terminals for masters or slaves
DCN4-TB4
CompoNet Terminator
For IP20 use
–
Plugs in to DCN4-MD4 or DCN4-TR4
DCN4-TM4
CompoNet connector tool
For DCN4-connectors
–
To attach DCN4-connectors to DCA4-4F10 flat cable
DWT-A01
40
Compact I/O SRT2
Remote I/O
Omron's unique CompoBus/S is the original I/O bus for machine automation. With
free topology and up to 500 m bus length in long-distance mode, it can be
used as a remote I/O system. In high-speed mode (100 m max.) the guaranteed submilli-second cycle time makes it ideal for efficient machine control. Used with the
compact CPM2C-S PLC as master, your machine control system will fit in the smallest spaces.
Compact size in IP20 housing
Fast cycle time; less than 1 ms per 256 I/O points
Easy set-up; no software required
Choice of 4- 8- and 16-point Digital I/O; transistor-, and relay models
Analog In/Outputs and customisable modules available
2
•
•
•
•
•
Ordering information
Unit type
Specifications
Size in mm (HxWxD)
Remarks
Order code
4-point PNP input unit
24 VDC, 6 mA per point
48x80x50
Compact IP20 I/O
SRT2-ID04-1
8-point PNP input unit
24 VDC, 6 mA per point
48x80x50
Compact IP20 I/O
SRT2-ID08-1
16-point PNP input unit
24 VDC, 6 mA per point
48x105x50
Compact IP20 I/O
SRT2-ID16-1
16-point PNP input unit
24 VDC, 6 mA per point
50x180x59
3-tier connection for direct sensor wiring
SRT2-ID16T-1
4-point PNP output unit
24 VDC, 0.3 A per point
48x80x50
Compact IP20 I/O
SRT2-OD04-1
8-point PNP output unit
24 VDC, 0.3 A per point
48x80x50
Compact IP20 I/O
SRT2-OD08-1
16-point PNP output unit
24 VDC, 0.3 A per point
48x105x50
Compact IP20 I/O
SRT2-OD16-1
16-point PNP output unit
24 VDC, 0.5 A per point
50x180x59
3-tier connection for direct sensor/actuator wiring
SRT2-OD16T-1
8-point input + 8-point output unit (PNP)
24 VDC, input 6 mA, output 0.3 A per point
50x180x59
3-tier connection for direct actuator wiring
SRT2-MD16T-1
8-point relay output unit
Max. 3 A per point
50x100x50
with easy-to-replace relays
SRT2-ROC08
16-point relay output unit
Max. 3 A per point
50x155x50
with easy-to-replace relays
SRT2-ROC16
4-Channel analog input unit
0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V,
0 to 20 mA, 4 to 20 mA
48x105x50
Resolution 1/6000, conversion time 4 ms (4 inputs)
SRT2-AD04
2-Channel analog output unit
0 to 5 V, 1 to 5 V, 0 to 10 V, -10 to 10 V,
0 to 20 mA, 4 to 20 mA
48x105x50
Resolution 1/6000, conversion time 2 ms (2 outputs)
SRT2-DA02
Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the "-1" from the model code.
Accessories
Type
Order code
CompoBus/S 4-wire flatcable for power and communication (100 m)
SCA1-4F10
CompoBus/S branch connector (IDC) for flatcable
SCN1-TH4
CompoBus/S termination connector (IDC) for flatcable
SCN1-TH4T
CompoBus/S termination block (screw connection)
SRS1-T
Remote I/O
Fast and easy over CompoBus/S
41
Field I/O DRT2
Remote I/O
IP67 DeviceNet I/O
Rugged I/O units for field mounting. The DRT2 slave units feature internal diagnostic
and maintenance data collection, which can be accessed over the network. Power
supply status, I/O response times, operation counters and on-time monitor data is
available at all times, and is internally checked against user-defined limits. Maintenance warnings will be generated when limits are exceeded. Using CX-One or NSseries HMI with Smart Active Parts for visualisation, this allows more efficient system
setup, commissioning and troubleshooting without any additional programming.
• IP67 protection, DRT2 versions are also oil- and welding-spatter proof
• Internal circuits powered by DeviceNet; fewer connections means less installation
errors
• Smart Slave functions for diagnostics and preventive maintenance
• Indication of broken wire and short-circuit in I/O signals
• M12 connectors for fast installation
Ordering information
Unit type
Specifications
Size in mm Remarks
(HxWxD)
Order code
4-point PNP input unit
24 V, 6 mA
123x60x44 Separate I/O power supply connection DRT2-ID04CL-1
8-point PNP input unit
24 V, 6 mA
175x60x44 Separate I/O power supply connection DRT2-ID08CL-1
8-point PNP input unit
24 V, 11 mA, with power short-circuit and sensor disconnection detection 175x60x38 Unit power supply via DeviceNet cable DRT2-ID08C-1
16-point PNP input unit
24 V, 6 mA, 2 inputs per M12 connector
175x60x44 Separate I/O power supply connection DRT2-HD16CL-1
16-point PNP input unit
24 V, 11 mA, 2 inputs per M12 connector,
with power short-circuit and sensor disconnection detection
175x60x38 Unit power supply via DeviceNet cable DRT2-HD16C-1
4-point PNP output unit
24 V, 0.5 A per point
123x60x44 Separate I/O power supply connection DRT2-OD04CL-1
8-point PNP output unit
24 V, 0.5 A per point
175x60x44 Separate I/O power supply connection DRT2-OD08CL-1
8-point PNP output unit
24 V, 1.5 A per point (8 A total), with short-circuit protection + indication
175x60x44 Separate I/O power supply connection DRT2-OD08C-1
16-point PNP output unit
24 V, 0.5 A per point, 2 points per M12 connector
175x60x44 Separate I/O power supply connection DRT2-WD16CL-1
8-point input + 8-point PNP output unit
24 V, 6 mA input, 0.5 A output per point, 2 points per M12 connector
175x60x44 Separate I/O power supply connection DRT2-MD16CL-1
Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the "-1" from the model code.
Accessories
Unit type
Specifications
Order code
DeviceNet thin cable
with one M12 socket connector (female), 1 m
DCA1-5CN01F1
DeviceNet thin cable
with one M12 socket connector (female), 2 m
DCA1-5CN02F1
DeviceNet thin cable
with one M12 socket connector (female), 5 m
DCA1-5CN05F1
DeviceNet thin cable
with one M12 socket connector (female) and one M12 plug connector (male), 1 m
DCA1-5CN01W1
DeviceNet thin cable
with one M12 socket connector (female) and one M12 plug connector (male), 2 m
DCA1-5CN02W1
DeviceNet thin cable
with one M12 socket connector (female) and one M12 plug connector (male), 5 m
DCA1-5CN05W1
DeviceNet T-connector for thin cable
with two M12 socket connectors (female) + one M12 plug connector (male)
DCN2-1
DeviceNet terminator
with M12 plug connector
DRS2-1
Power supply cable
with one 7/8 inches socket connector (female), 2 m
XS4F-D421-102-A
Power supply cable
with one 7/8 inches socket connector (female), 5 m
XS4F-D421-105-A
Power supply cable
with one 7/8 inches socket connector (female) and one 7/8 inches plug connector (male), 2 m
XS4W-D421-102-A
Power supply cable
with one 7/8 inches socket connector (female) and one 7/8 inches plug connector (male), 5 m
XS4W-D421-105-A
Power supply T-connector
with two 7/8 inches socket connectors (female) + one 7/8 inches plug connector (male)
XS4R-D424-5
4-wire I/O connection cable
with one M12 plug connector (male), 1 m
XS2H-D421-C80-A
4-wire I/O connection cable
with one M12 plug connector (male), 2 m
XS2H-D421-D80-A
4-wire I/O connection cable
with one M12 plug connector (male), 5 m
XS2H-D421-G80-A
4-wire I/O connection cable
with one M12 socket connector (female) and one M12 plug connector (male), 1 m
XS2W-D421-C81-A
4-wire I/O connection cable
with one M12 socket connector (female) and one M12 plug connector (male), 2 m
XS2W-D421-D81-A
4-wire I/O connection cable
with one M12 socket connector (female) and one M12 plug connector (male), 5 m
XS2W-D421-G81-A
Y-connector for 16-point I/O units
Splits the 2 I/O points per M12 connector to two M12 connectors
XS2R-D426-1
Y-connector cable for 16-point I/O units
Splits the 2 I/O points per M12 connector to two M12 connectors, 1 m
XS2R-D426-C11-F
M12 connector
M12 plug connector (male), solder type
XS2G-D421
M12 connector
M12 socket connector (female), solder type
XS2C-D421
IP67 cap for M12 sockets
Metal cap for unused I/O connections
XS2Z-12
42
Field I/O CRT1B
Remote I/O
• IP54 protection, dust-proof and splash water resistant
• Internal circuits powered by CompoNet; fewer connections means less installation
errors
• Smart Slave functions for diagnostics and preventive maintenance
• Indication of broken wire and short-circuit in I/O signals
• Sensor connectors or push-in screwless terminals for fast installation
Ordering information
Unit type
Specifications
Size in mm
(HxWxD)
Remarks
Order code
2-point PNP input unit
24 VDC, 6 mA per point
95x50x51
e-CON sensor connectors,
power supply via CompoNet cable (50 cm attached)
CRT1B-ID02SP-1
4-point PNP input unit
24 VDC, 6 mA per point
95x50x51
e-CON sensor connectors,
power supply via CompoNet cable (50 cm attached)
CRT1B-ID04SP-1
2-point PNP output unit
24 VDC, 0.2 A per point
95x50x51
e-CON sensor connectors,
power supply via CompoNet cable (50 cm attached)
CRT1B-OD02SP-1
2-point input + 2-point PNP output unit
24 VDC, 6 mA per point (input),
0.2 A per point (Output)
95x50x51
Screwless push-in connectors,
power supply via CompoNet cable (50 cm attached)
CRT1B-MD04SLP-1
Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the "-1" from the model code.
Accessories
Unit type
Specifications
Size in mm
(HxWxD)
Remarks
Order code
CompoNet Repeater unit
1 upstream port + 1 downstream port
50x95x43
For extending CompoNet trunk lines, or creating
branch lines
CRS1-RPT01
CompoNet 4-wire flat cable
For IP54 use
100 m
For power supply + communication,
use with DCN5-connectors
DCA5-4F10
CompoNet Branch connector for trunk line For IP54 use
–
To create a branching point on a trunk line
DCN5-TR4
CompoNet Branch line end connector
For IP54 use
–
To connect a branch line to a trunk line
DCN5-BR4
CompoNet Terminator
For IP54 use
–
Plugs in to DCN5-TR4
DCN5-TM4
CompoNet connector tool
For DCN5-connectors
–
To attach DCN5-connectors to DCA5-4F10 flat cable DWT-A02
43
2
IP67 I/O offers a high degree of protection, but requires costly connection technology.
CompoNet IP54 I/O offers an alternative with standard I/O connections, easy communication wiring with IDC connectors, all in a dust-proof and splash-resistant case.
High-speed communication and flexible topology make it ideal for finely distributed
control.
Remote I/O
IP54 CompoNet I/O –
The alternative solution for field-mounted I/O
Field I/O SRT2
Remote I/O
IP67 CompoBus/S
Rugged I/O units for field mounting. Omron's unique CompoBus/S is the most efficient I/O bus for machine automation. With free topology and up to 500 m bus length
in long-distance mode, it can be used as a remote I/O system. In high-speed mode
(100 m max.) the guaranteed sub-millisecond cycle time makes it ideal for efficient
machine control. With IP67 slave modules distributed throughout the machine, the
need for protective enclosures is minimised.
•
•
•
•
•
IP67 protection against dust and water
Fast cycle time; less than 1 ms for 256 I/O points
Easy setup; no software required
Choice of 4- and 8-point Digital I/O
M12 connectors for easy field wiring
Ordering information
Unit type
Specifications
Size in mm (HxWxD)
Order code
4-point PNP input unit
24 V, 6 mA
114x54x45
SRT2-ID04CL-1
8-point PNP input unit
24 V, 6 mA
114x54x45
SRT2-ID08CL-1
4-point PNP output unit
24 V, 0.5 A per point
114x54x45
SRT2-OD04CL-1
8-point PNP output unit
24 V, 0.5 A per point
114x54x45
SRT2-OD08CL-1
Note: To order models with NPN (sinking) outputs and corresponding inputs (+V common), omit the "-1" from the model code.
Accessories
Unit type
Specifications
Remarks
Order code
CompoBus/S terminator
with M12 plug connector
–
SRS2-1
M12 connector
M12 plug connector (male), screw type
For CompoBus/S 4-wire round cable
XS2G-D4S7
M12 connector
M12 socket connector (female), screw type
For CompoBus/S 4-wire round cable
XS2C-D4S7
M12 T-connector (4-wire)
with two M12 socket connectors (female) + one M12 plug connector (male)
–
XS2R-D427-5
4-wire I/O connection cable
with one M12 plug connector (male), 1 m
–
XS2H-D421-C80-A
4-wire I/O connection cable
with one M12 plug connector (male), 2 m
–
XS2H-D421-D80-A
4-wire I/O connection cable
with one M12 plug connector (male), 5 m
–
XS2H-D421-G80-A
4-wire I/O connection cable
with one M12 socket connector (female) and one M12 plug connector (male), 1 m
–
XS2W-D421-C81-A
4-wire I/O connection cable
with one M12 socket connector (female) and one M12 plug connector (male), 2 m
–
XS2W-D421-D81-A
4-wire I/O connection cable
with one M12 socket connector (female) and one M12 plug connector (male), 5 m
–
XS2W-D421-G81-A
Y-connector for 16-point I/O units
Splits the 2 I/O points per M12 connector to two M12 connectors
–
XS2R-D426-1
Y-connector cable for 16-point I/O units
Splits the 2 I/O points per M12 connector to two M12 connectors, 1 m
–
XS2R-D426-C11-F
M12 connector
M12 plug connector (male), solder type
–
XS2G-D421
M12 connector
M12 socket connector (female), solder type
–
XS2C-D421
IP67 cap for M12 sockets
Metal cap for unused I/O connections
–
XS2Z-12
44
WD30/WT30
Remote I/O
There are applications where a normal wired connection is not practical,
impossible to maintain or prone to disturbance. WD30 provides a wireless masterslave data link for up to 63 DeviceNet sub-networks. Alternatively, a WD30 master
unit can directly control WT30 wireless I/O slave units. For direct access to wireless remote I/O without passing through DeviceNet, the WT30 master is equipped
with a serial CompoWay/F interface.
2
• Easy to set-up: Extensive diagnostic features such as signal strength
measurement and channel usage
• Each Wireless master handles up to 100/100 words, input/output data.
Up to 63 Wireless Slaves per Wireless Master
• Uses spread spectrum technology for superior noise resistance
in manufacturing environments
• Relay function for extension of communication range (3 repeaters max.)
• Explicit message communication
Ordering information
Unit type
Size in mm (HxWxD) Order code
Wireless Master unit; slave on DeviceNet network; with 2 pencil antennas
80x159x35
WD30-ME
Wireless Master unit; slave on DeviceNet network; with 2 magnetic base antennas
80x95x35
WD30-ME01
Wireless Slave unit; Master on DeviceNet network; with 2 pencil antennas
80x159x35
WD30-SE
Wireless Slave unit; Master on DeviceNet network; with 2 magnetic base antennas
80x95x35
WD30-SE01
Wireless Master unit; controlled by serial RS232-C link (antenna not included)
105x90x40
WT30-M01-FLK
Wireless Slave unit; 16 digital inputs (NPN/PNP)
105x90x40
WT30-SID16
Wireless slave unit; 8 digital inputs + 8 digital outputs (PNP)
105x90x40
WT30-SMD16-1
Accessories
Unit type
Remarks
Size
Order code
Magnet base antennas (set of 2), with 2 m cable
–
115x∅36
WT30-AT001
Pencil antennas (set of 2)
–
75
WT30-AT003
DIN-rail mounting bracket for WT30
–
–
WT30-FT001
DeviceNet thin cable
with one M12 socket connector (female)
1m
DCA1-5CN01F1
DeviceNet thin cable
with one M12 socket connector (female)
2m
DCA1-5CN02F1
DeviceNet thin cable
with one M12 socket connector (female)
5m
DCA1-5CN05F1
DeviceNet thin cable
with one M12 socket connector (female) and one M12 plug connector (male)
1m
DCA1-5CN01W1
DeviceNet thin cable
with one M12 socket connector (female) and one M12 plug connector (male)
2m
DCA1-5CN02W1
DeviceNet thin cable
with one M12 socket connector (female) and one M12 plug connector (male)
5m
DCA1-5CN05W1
DeviceNet T-connector for thin cable
with two M12 socket connectors (female) + one M12 plug connector (male)
–
DCN2-1
DeviceNet terminator
with M12 plug connector
–
DRS2-1
Remote I/O
Wireless DeviceNet communication
45
Human machine interfaces (HMI)
THE RELIABLE INDUSTRIAL DIALOGUE
DyaloX – The reliable choice
The DyaloX Industrial PC is designed to provide exceptional performance, operating round-the-clock throughout its lifetime. It
offers self-diagnostic hardware and software, such as the Omron RAS solution, to ensure that DyaloX IPCs will keep on running
long after other IPCs have given up. Packaged with our HMI software, CX-Supervisor, it is the ultimate PC based HMI solution.
• Self-diagnostic system as early warning system to avoid machine downtime
• Fan-less, HDD-less (Reliable flash storage memory in different sizes)
• 3 year warranty, 5 year minimum availability, 7 year courier repair service
Touch screen
PC based HMI
46
Integrated Controller
Display size
Box IPC
Panel IPC
15 inch/
17 inch
12 inch/
15 inch
12.1 inch
10.4 inch
8.4 inch
5.7 inch
15 inch
DyaloX
DyaloX
NSJ12
NSJ10
NSJ8
NSJ5
NS15
Page 48
Page 48
Page 56
Page 56
Page 58
Page 58
Page 60
HMI
3
Interaction type
Function keys
Scalable HMI
Compact HMI
4 lines
2 lines
Display size
12.1 inch/
10.4 inch
8.4 inch
5.7 inch
5.7 inch
5.7 inch
3.5 inch/
3.8 inch
NS12/NS10
NS8
NS5
NS5
Handheld
NQ5
NQ3
NT11
NT2S
Page 60
Page 60
Page 61
Page 62
Page 65
Page 65
Page 66
Page 67
47
PC based HMI
DyaloX
Industrial PC created for 24/7 operation in
the most demanding industrial environments
The DyaloX Industrial PC is designed to provide exceptional performance operating
round-the-clock throughout its lifetime. Drawing on our many years’ experience in
industrial-class standalone PC-based equipment, we have created unique self-diagnostic hardware and software, such as the Omron RAS solution, to ensure that DyaloX
IPCs will keep on running long after other IPCs have given up.
•
•
•
•
•
Omron RAS solution
Industrial-grade 600 MHz or 1.3 GHz Intel Celeron CPU
Reliable silicon storage up to 8GB
Fan-less heat sink cooling for enhanced reliability
3 year warranty, 5 year minimum availability, 7 year courier repair service
Ordering information
DyaloX IPC
Type
Industrial PC panel, 600 MHz CPU
Industrial PC panel, 1.3 GHz CPU
Industrial PC box, 1.3 GHz CPU
Order Code
12 inches, 600 MHz, 256 MB internal, black
NSA12-TX11B
12 inches, 600 MHz, 256 MB internal, silver
NSA12-TX11S
15 inches, 600 MHz, 256 MB internal, black
NSA15-TX11B
15 inches, 600 MHz, 256 MB internal, silver
NSA15-TX11S
12 inches, 600 MHz, 512 MB internal, black
NSA12-TX12B
12 inches, 600 MHz, 512 MB internal, silver
NSA12-TX12S
15 inches, 600 MHz, 512 MB internal, black
NSA15-TX12B
15 inches, 600 MHz, 512 MB internal, silver
NSA15-TX12S
12 inches, 1.3 GHz, 512 MB internal, 2 GB storage, black
NSA12-TX01B-E
12 inches, 1.3 GHz, 512 MB internal, 2 GB storage, silver
NSA12-TX01S-E
15 inches, 1.3 GHz, 512 MB internal, 2 GB storage, black
NSA15-TX01B-E
15 inches, 1.3 GHz, 512 MB internal, 2 GB storage, silver
NSA15-TX01S-E
1.3 GHz, RAM: 512 MB, DOM: 2 GB
NSA-CPU01-E
1.3 GHz, RAM: 512 MB, DOM: 4 GB
NSA-CPU02-E
1.3 GHz, RAM: 1 GB, DOM: 2 GB
NSA-CPU03-E
1.3 GHz, RAM: 1 GB, DOM: 4 GB
NSA-CPU04-E
Touch panel
Type
Touchscreen panel
Order Code
15 inches, black
NSA-TX151B
15 inches, silver
NSA-TX151S
17 inches, black
NSA-TY171B
17 inches, silver
NSA-TY171S
Accessories
Type
Order Code
2 GB CF with XP Embedded English
NSA-CEX02-E
4 GB CF with XP Embedded English
NSA-CEX04-E
8 GB CF with XP Embedded English
NSA-CEX08-E
80 GB HDD, no OS
NSA-HEX80
512 MB DDR-SD RAM (non-ECC)
NSA-MR581
1 GB DDR-SD RAM (non-ECC)
NSA-MR191
DVI & USB cable 0.1 m
NSA-DU02
DVI & USB cable 2 m
NSA-DU22
DVI & USB cable 5 m
NSA-DU52
DVI cable 10 m
NSA-DV101
Set of 5 Anti-reflection sheets for 12 inches
NS12-KBA04
Set of 5 Anti-reflection sheets for 15 inches
NS15-KBA04
Battery for NSA12/15-TX01, NSA-CPU
NSA-BAT01
Battery for NSA12/15-TX12
NSA-BAT03
48
PC based HMI
DyaloX
DyaloX IPC specifications
Item
NSA1_-TX1_
NSA1_-TX01_-E
OS
CF with Windows XP
embedded*1
Preinstalled Windows XP embedded
Processor
600 MHz Intel Celeron-M 1.3 GHz Intel Celeron-M Processor
Processor
Storage device Type
Industrial CF memory or DiskOnModule (Flash memory)
HDD*1
Memory
Interface
NSA-CPU04-E
4 GB
2 GB
4 GB
CF: 100,000 write
NAND flash memory: 100,000 write cycles (to the same block)*2
cycle/block
HDD: 2 years at
24 hours/day operation,
3 years at 8 hours/day
operation
Main memory
TX11: 256 MB DDRSDRAM (non-ECC)
TX12: 512 MB DDRSDRAM (non-ECC)
Cache memory
512 KB Level 2 cache memory (built into the CPU)
Keyboard
-
PS/2 keyboard with 6-pin MINI DIN connector
Mouse
-
PS/2 mouse with MINI DIN connector
Serial ports
2 ports conforming to EIA RS-232C for 9-pin D-SUB male connectors
Ethernet
2 x 10 BASE-T/
One 10 BASE-T/100 BASE-TX port for an RJ45 connector
100 BASE-TX RJ45 connector
USB ports
4 x USB 2.0/1.1
2 USB 2.0/1.1 ports for 2 USB 2.0/1.1 ports for USB type-A connectors
for type-A connectors. USB type-A connectors 2 USB 1.1 for USB type-A connectors
(2 on front panel, cable
3 m max.)
Memory Card
1 CF Card slot
Video output
-
Audio
-
3
Service life
(write cycles)
512 MB DDR-SDRAM (non-ECC)
Line-In/Line-Out/Mic-In for mini jack
PCI expansion bus, 2 slots
3-pin connector port for the UPS power interruption signal
Status LEDindicators
4 (RUN/BATLOW/ERR/DIAG)
Motherboard RAS
functions
1GB DDR-SDRAM (non-ECC)
1 DVI port for DVI-I connector
External input port
RAS functions Special RAS board
functions
Alive connection monitoring, device restart, timer start, startup and shutdown monitoring, backlight lit time measurement,
UPS power interrupt signal output, and logging functions
Standard PC RAS info, post error logging, post error retry, CMOS data recovery
POWER LED indicator
Yes (green)
Service life*3
50,000 hours at 40°C
Battery life
NSA-CPU03-E
CF: 2/4/8 GB (with OS) 2 GB
IDE I/F*1
HDD: 80GB (without OS)
SATA I/F*1
PCI expansion bus,
1 slot
2 GB
NSA-CPU02-E
Capacity
Expansion slots
Special RAS
board
NSA-CPU01-E
HMI
Main specifications
50,000 hours at 30°C
Main board
5 years at 25°C
(NSA-BAT03)
5 years at 25°C (NSA-BAT01)
RAS board
5 years at 25°C
(NSA-BAT03)
5 years at 25°C (NSA-BAT02)
*1
*2
Sold separately
Calculate condition
Free area:
500 MB (*excluding OS & Application)
Overwrite data size/time: 0.5 MB/time
Overwrite times/day:
10,000 times/day
MTBF:
(500 MB *100,000 times) / (0.5 MB *10,000 times/day) = 10,000 days = 27 years
*3
The service life is a guideline that is provided strictly for reference. It varies with factors such as the installation location and operating conditions.
49
PC based HMI
DyaloX
Touch Panel specifications
Item
NSA12-TX11_-E
NSA12-TX12_-E
Display panel Type
Backlight
NSA15-TX11_-E
NSA15-TX12_-E
NSA12-TX01_-E
NSA15-TX01_-E
15 inches
12.1 inches
15 inches
4 CCFL
2 CCFL
4 CCFL
185.5×247
229×305
TFT color LCD
Size
12.1 inches
Resolution
1024×768 dots
Brightness
300 cd/m2 (typcial)
Viewing angle
130° left to right, 90° up and down
Colors displayed
262,144
Type
2 CCFL
Brightness adjustment Three-level software adjustment*1
Touch panel
Interface
Backlight not lit
detection
The software reads the lamp burnout detection signal from the inverter*2
Service life
50,000 hours min.*3
Type
Analog resistive type
Effective input area
Size in mm (H×W)
185.5×247
Operating service life
10,000,000 operations (with non-stop key stroking using fingers to input)
100,000 characters (with non-stop character entry using a stylus to input)
USB ports
4 x USB2.0/1.1 for type-A connectors (2 on front side)
Video Input
-
POWER LED indicator
Yes (green)
Service life*4
50,000 hours at 25°C
229×305
2 x USB2.0/1.1 for type-A connectors
50,000 hours at 40°C
*1
*2
*3
The contrast cannot be adjusted significantly.
It is not the service life, but rather lamp failure due to hardware problems such as a broken wire that is detected. Backlight not lit detection means both backlight lamps have burnt out.
The service life is a guideline for maximum contrast at room temperature with normal humidity and is provided strictly for reference. It varies significantly with the ambient temperature.
The service life will be shorter under extreme (high or low) temperature conditions and falls off sharply particularly under low-temperature conditions.
*4 The service life is a guideline that is provided strictly for reference. It varies with factors such as the installation location and operating conditions.
General specifications
Item
NSA1_-TX11_-E
NSA1_-TX12_-E
Rated supply voltage
24 VDC
Allowable supply voltage range
20.4 VDC to 27.6 VDC (24 VDC ±15%)
20.0 VDC to 27.6 VDC (24 VDC ±15%)
Power consumption
12 inches: 65 W max.
15 inches: 75 W max.
12 inches: 80 W max.
15 inches: 100 W max.
Ambient operating temperature
0 to 50°C*1
Ambient storage temperature
-10 to 60°C*1
Ambient operating humidity
10% to 80% with no condensation*1
Ambient storage humidity
10% to 85% with no condensation*1
Operating atmosphere
Must be free of corrosive gases.
Must be fairly dust free.
Noise resistance
Conforms to IEC6100-4-4, power supply line: 2 kV
Vibration resistance (in operation)
Conforms to JIS C0041, 0.05 mm amplitude at 10 to 55 Hz for 50 min. Each in the X, Y, and Z directions
Shock resistance (in operation)
Conforms to JIS C0041, 196 m/s2 three times each in the X, Y, and Z directions
Degree of protection
Front panel: IP65 or the equivalent*1
Weight
12 inches: 5 kg max.
15 inches: 7 kg max.
12 inches: 5 kg max.
15 inches: 7 kg max.
4 kg max.
Dimensions in mm (HxWxD)
12 inches:
281×342×98
15 inches: 296.5×397.5×103
12 inches: 264×322×100
15 inches: 312×384×108
233x308x76.5
*1
NSA1_-TX01_-E
NSA-CPU0_-E
60 W max.
–
For more information, please check the user manual.
CF & HDD
Item
NSA-CEX02
NSA-CEX04
NSA-CEX08
NSA-HEX80
Storage capacity
2 GB
4 GB
8 GB
80 GB
Interface
IDE
50
SATA
PC based HMI
DyaloX
Touch panel specifications (box model)
NSA-TX151
Display panel Type
TFT color LCD
Backlight
NSA-TY171
Size
15.0 inches
17.0 inches
Resolution
1024×768 dots
1280×1024 dots
Brightness
270 cd/m2 (typcial)
200 cd/m2 (typcial)
Viewing angle
130° left to right, 90° up and down
Colors displayed
262,144
Type
2 CCFL
HMI
Item
4 CCFL
Touch panel
Interface
Service life
50,000 hours min.*1
Type
Analog resistive type
Effective input area
Size in mm (H×W)
229×305
Operating service life
10,000,000 operations (with non-stop key stroking using fingers to input)
100,000 characters (with non-stop character entry using a stylus to input)
USB ports
3 x USB 1.1 for type-A connectors (2 on front side)
1 x USB 1.1 (used for touch) for type-B connector
Video Input
1 x DVI-D port
POWER LED indicator
Yes (green)
Service life*2
50,000 hours at 30°C
3
Brightness adjustment 10 level adjustment by rotary switch
272×340
*1
The service life is a guideline for maximum contrast at room temperature with normal humidity and is provided strictly for reference. It varies significantly with the ambient temperature.
The service life will be shorter under extreme (high or low) temperature conditions and falls off sharply particularly under low-temperature conditions.
*2
The service life is a guideline that is provided strictly for reference. It varies with factors such as the installation location and operating conditions.
General specifications (box model)
Item
NSA-TX151
Rated supply voltage
24 VDC
Allowable supply voltage range
20.0 VDC to 27.6 VDC (24 VDC ±15%)
Power consumption
40 W max.
Ambient operating temperature
0 to 50°C*1
Ambient storage temperature
-10 to 60°C*1
Ambient operating humidity
10% to 80% with no condensation*1
Ambient storage humidity
10% to 85% with no condensation*1
Operating atmosphere
Must be free of corrosive gases.
Must be fairly dust free.
Noise resistance
Conforms to IEC6100-4-4, power supply line: 2 kV
Vibration resistance (in operation)
Conforms to JIS C0041, 0.05 mm amplitude at 10 to 55 Hz for 50 min. Each in the X, Y, and Z directions
Shock resistance (in operation)
Conforms to JIS C0041, 196 m/s2 three times each in the X, Y, and Z directions
Degree of protection
IP65F (front panel oil protection)*1
Weight
6 kg max.
7 kg max.
Dimensions in mm (HxWxD)
328x404x57
371x436x57
*1
NSA-TY171
55 W max.
For more information, please check the user manual.
51
Selection table
HMI & Control with SYSMAC One
Model
NSJ12
Type of Display 12.1 inch colour TFT
Display Size / Resolution 246×184.5 mm
(800×600 pixels)
Control CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 μs
Communication DeviceNet Master/Slave or
PROFIBUS Master and optional
Ethernet interface
Expansion (1 board max.) Ethernet, Controller Link,
I/O extension
Dimensions in mm (HxWxD) Without expansion unit
241×315×73.3
With expansion unit
241×315×89.3
Page 56
52
NSJ10
NSJ8
NSJ5
10.4 inch colour TFT
8.4 inch colour TFT
5.7 inch colour TFT or STN
215.5×162.4 mm
(640×480 pixels)
170.9×128.2 mm
(640×480 pixels)
117.2×88.4 mm
(320×240 pixels)
CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 μs
CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 μs
CJ1G-CPU45H;
60k-steps program memory,
128k-words data memory,
logic instruction time 0.04 μs
CJ1M-CPU13;
20k-steps program memory,
32k-words data memory,
logic instruction time 0.04 μs
CJ1M-CPU13;
20k-steps program memory,
32k-words data memory,
logic instruction time 0.04 μs
DeviceNet Master/Slave or
PROFIBUS Master and optional
Ethernet interface
DeviceNet Master/Slave or
PROFIBUS Master and optional
Ethernet interface
DeviceNet Master/Slave or
PROFIBUS Master and optional
Ethernet interface
Ethernet, Controller Link,
I/O extension
Ethernet, Controller Link,
I/O extension
Ethernet, Controller Link,
I/O extension
Without expansion unit
241×315×73.3
With expansion unit
241×315×89.3
Without expansion unit
177×232×73.3
With expansion unit
177×232×89.3
Without expansion unit
195×142×79
With expansion unit
195×142×95
56
58
58
Scalable HMI – NS
Model
NS15
Display 15 inch TFT colour
NS12
NS10
NS8
NS5
HMI
Scalable HMI – NS
NS5 Handheld
12.1 inch TFT colour
10.4 inch TFT colour
8.4 inch TFT colour
5.7 inch Monochrome
or STN/TFT colour
5.7 inch STN colour
800×600 pixels
640×480 pixels
640×480 pixels
320×240 pixels
320×240 pixels
Nr. of colours 256
(32,768 for image data)
256
(32,768 for image data)
256
(32,768 for image data)
256
(32,768 for image data)
Monochrome
16 greyscales,
STN/TFT 256 colours
(STN 4096, TFT 32,768
for image data)
256 colours
(4096 colours for
image data)
Memory Size 60MB screen memory
60MB screen memory,
32,768 words + 32,768
bits internal memory
and 8192 words + 8192
bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory
and 8192 words + 8192
bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory
and 8192 words + 8192
bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory
and 8192 words + 8192
bits
retentative memory
60MB screen memory,
32,768 words + 32,768
bits internal memory
and 8192 words + 8192
bits
retentative memory
Ethernet, Controller
Link,
Video input board
(RGB/Composite)
241×315×48.5
Ethernet, Controller
Link,
Video input board
(RGB/Composite)
241×315×48.5
Ethernet, Video input
board (RGB/Composite)
Ethernet
RS-232 or RS-422
communication
depending on cable
177×195×48.5
142×195×54
176×223×70.5
(excl. emergency
button)
60
60
60
61
62
3
Resolution 1024×768 pixels (XGA)
Options Controller Link,
Video input board
(RGB/Composite)
Dimensions in mm (HxWxD) 300×400×80
Page 60
53
54
HMI
HMI-Connection
System configuration
(Picture represents backside of a SYSMAC One unit)
Memory card interface
(Display part)
Memory card interface
(Controller part)
CF
HMI
For application back up and
saving PLC data, etc.
RS-232C
Port C
DeviceNet or
PROFIBUS
CF
For screen captures, recipes and
saving data log, etc.
3
Available both on NS and SYSMAC One series
Only available on SYSMAC One series
DeviceNet
PROFIBUS
RS-232C port B
RS-232C port A
Ethernet
USB slave
Only available on NS series
Printer
PC
RS-232C, DOS/V transfer cable
XW2Z-S002 (2m)
RS-422A/485 conversion unit
CJ1W-CIF11 (~50m)
NS-AL002 (~500m)
PictBridge technology
PC
General purpose USB cable
PLC
PLC
USB serial conversion cable
CS1W-CIF31
Barcode reader
Serial
WE70
Wireless
Printer
Serial
RS-422A/485 conversion unit
CJ1W-CIF11
NS-AL002
PC
Temperature controller
E5_N, EJ1, etc.
PLC
RS-232C, PT-PLC connection cable
XW2Z-200T (2m)
XW2Z-500T (5m)
Barcode reader
PC
I/O terminals
RS-232C, DOS/V transfer cable
XW2Z-S002 (2m)
USB, serial conversion cable
CS1W-CIF31
Inverters
CIMR-V7/F7, etc.
Memory link, single board Computer, etc.
Temperature controller, E5_N, EJ1, etc.
GRT1 series
SmartSlice I/O
CompoWay/F(direct serial connection to HMI)
Inverter
RS-422A/485
Other company´s equipments
non-Omron device
55
HMI & Control
NSJ12/NSJ10
HMI with integrated PLC and Network
interface
The NSJ12 and NSJ10 are combined with a CJ1G-CPU 45H and a DeviceNet or
PROFIBUS interface fitted into a compact housing occupying less panel space than
the separate products. Programming can be done via the standard high-speed USB
port. The SYSMAC One is completely transparent, so the PLC, network (including field
devices) and HMI can be accessed via a single port. A great advantage when
servicing your machine remotely.
•
•
•
•
•
HMI + PLC with 2 separate CPUs for greater performance and reliability
Transparent architecture for easy remote maintenance
Compact design occupying less panel space
Flexible and cost-effective solution with multiple screen sizes, CPUs & networks
Smart Active Parts for graphical interaction to field devices
Ordering Information
Type
Order Code
SYSMAC One 12.1" TFT
SYSMAC One 12.1" TFT
SYSMAC One 10" TFT
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
SYSMAC One 10" TFT
CJ1G-CPU45H
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
with Ethernet
no Ethernet
with Ethernet
no Ethernet
Black
NSJ12-TS01B-G5P
Ivory
NSJ12-TS01-G5P
Black
NSJ12-TS00B-G5P
Ivory
NSJ12-TS00-G5P
Black
NSJ10-TV01B-G5P
Ivory
NSJ10-TV01-G5P
Black
NSJ10-TV00B-G5P
Ivory
NSJ10-TV00-G5P
Type
Order Code
SYSMAC One 12.1" TFT
SYSMAC One 12.1" TFT
SYSMAC One 10" TFT
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
SYSMAC One 10" TFT
CJ1G-CPU45H
DeviceNet
DeviceNet
DeviceNet
DeviceNet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
Black
NSJ12-TS01B-G5D
Ivory
NSJ12-TS01-G5D
Black
NSJ12-TS00B-G5D
Ivory
NSJ12-TS00-G5D
Black
NSJ10-TV01B-G5D
Ivory
NSJ10-TV01-G5D
Black
NSJ10-TV00B-G5D
Ivory
NSJ10-TV00-G5D
Note: For the accessories, please refer to page 63
Specifications
Item
NSJ12-TS0_-G5D
Supply voltage
24 VDC
Allowable supply voltage range
20.4 to 27.6 VDC (24 VDC ±15%)
Power consumption
30 W max.
Current consumption
Controller Section Internal 5 V: 500 mA max.
DeviceNet Section Internal 5 V: 200 mA max., External 24 V: 18 mA max.
Inrush current *1
At 24 VAC: 10 A/20 ms max. for cold start at room temperature
Ambient operating temperature
(depending on angle of display surface off horizontal) *2
90° to 60°: 0 to 50°C
60° to 30°: 0 to 45°C
30° to 0°: Use prohibited
Ambient storage temperature
-20 to 60°C
Ambient operating humidity
0 to 40°C: 35% to 85% (with no condensation)
40 to 50°C: 35% to 60% (with no condensation)
Ambient operating environment
No corrosive gases
Insulation resistance
20 MΩ min. (at 100 VDC) between DC external and GR terminals
Dielectric strength
800 VDC for 1 min between DC external and GR terminals, leakage current: 10 mA max.
Noise immunity
2 kV on power supply line (conforming to IEC 61000-4-4)
Vibration resistance (during operation)
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y and Z directions for 80 minutes
Shock resistance (during operation)
147 m/s2, 3 times each in X, Y and Z directions
External
dimensions in
mm (W×H×D)
Without Expansion unit
315x241x73.3
With Expansion unit
315x241x89.3
Panel output dimensions
302+10×228+10 mm (W×H)
Panel thickness: 1.6 to 4.8
Grounding
100 Ω or less
Weight
2.7 kg max.
Degree of protection
Front operating panel: Equivalent to IP65F and NEMA4*3
56
NSJ10-TV0_-G5D
2.5 kg max.
HMI & Control
NSJ12/NSJ10
Item
NSJ12-TS0_-G5D
Battery life
5 years (at 25°C)
The SRAM and RTC will be backed up for 5 days after the battery runs low (i.e., after the indicator lights orange). The SRAM and RTC
will be backed up by a super capacitor for 5 minutes after removing the old battery (i.e., after turning ON power after 5 minutes).
NSJ10-TV0_-G5D
International standards
Conforms to cULus and EC Directives.
A delay circuit that charges a capacitor is used to limit the inrush current. If a hot start is performed when the power supply has been OFF only a short period of time, the capacitor will still
be charged and the inrush current specified above will be exceeded by up to approximately five times the specified value. When selecting fuses or breakers for external circuits, allow sufficient
margin in the melting temperatures, detection characteristics, and inrush current.
*2
Display angles off horizontal are as follows:
90°
ce
rfa
su
30°
3
lay
p
Dis
Horizontal 0°
*3
HMI
*1
May not be applicable in locations with long-term exposure to oil.
57
HMI & Control
NSJ8/NSJ5
HMI with integrated PLC and Network
interface
The NSJ8 and NSJ5 are combined either with a CJ1G-CPU 45H or with a low-cost
CJ1M-CPU13 PLC and a DeviceNet or PROFIBUS interface. It is fitted into a compact
housing occupying less panel space than the separate products. Programming can
be done via the standard high-speed USB port. The SYSMAC One is completely
transparent, so the PLC, network (including field devices) and HMI can be accessed
via a single port. A great advantage when servicing your machine remotely.
•
•
•
•
•
HMI + PLC with 2 separate CPUs for greater performance and reliability
Transparent architecture for easy remote maintenance
Compact design taking up less panel space
Flexible and cost effective solution with multiple screen sizes, CPUs & networks
Smart Active Parts for for graphical interaction to field devices
Ordering Information
Type
SYSMAC One 8.4" TFT
SYSMAC One 8.4" TFT
SYSMAC One 5.7" TFT
SYSMAC One 5.7" TFT
SYSMAC One 5.7" STN
SYSMAC One 5.7" STN
SYSMAC One 8.4" TFT
SYSMAC One 8.4" TFT
SYSMAC One 5.7" TFT
SYSMAC One 5.7" TFT
SYSMAC One 5.7" STN
SYSMAC One 5.7" STN
Order Code
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
CJ1M-CPU13
CJ1M-CPU13
CJ1M-CPU13
CJ1M-CPU13
CJ1M-CPU13
CJ1M-CPU13
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
PROFIBUS
with Ethernet
no Ethernet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
Black
NSJ8-TV01B-G5P
Ivory
NSJ8-TV01-G5P
Black
NSJ8-TV00B-G5P
Ivory
NSJ8-TV00-G5P
Black
NSJ5-TQ01B-G5P
Ivory
NSJ5-TQ01-G5P
Black
NSJ5-TQ00B-G5P
Ivory
NSJ5-TQ00-G5P
Black
NSJ5-SQ01B-G5P
Ivory
NSJ5-SQ01-G5P
Black
NSJ5-SQ00B-G5P
Ivory
NSJ5-SQ00-G5P
Black
NSJ8-TV01B-M3P
Ivory
NSJ8-TV01-M3P
Black
NSJ8-TV00B-M3P
Ivory
NSJ8-TV00-M3P
Black
NSJ5-TQ01B-M3P
Ivory
NSJ5-TQ01-M3P
Black
NSJ5-TQ00B-M3P
Ivory
NSJ5-TQ00-M3P
Black
NSJ5-SQ01B-M3P
Ivory
NSJ5-SQ01-M3P
Black
NSJ5-SQ00B-M3P
Ivory
NSJ5-SQ00-M3P
Type
SYSMAC One 8.4" TFT
SYSMAC One 8.4" TFT
SYSMAC One 5.7" TFT
SYSMAC One 5.7" TFT
SYSMAC One 5.7" STN
SYSMAC One 5.7" STN
58
Order Code
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
CJ1G-CPU45H
DeviceNet
DeviceNet
DeviceNet
DeviceNet
DeviceNet
DeviceNet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
Black
NSJ8-TV01B-G5D
Ivory
NSJ8-TV01-G5D
Black
NSJ8-TV00B-G5D
Ivory
NSJ8-TV00-G5D
Black
NSJ5-TQ01B-G5D
Ivory
NSJ5-TQ01-G5D
Black
NSJ5-TQ00B-G5D
Ivory
NSJ5-TQ00-G5D
Black
NSJ5-SQ01B-G5D
Ivory
NSJ5-SQ01-G5D
Black
NSJ5-SQ00B-G5D
Ivory
NSJ5-SQ00-G5D
HMI & Control
NSJ8/NSJ5
CJ1M-CPU13
SYSMAC One, 8.4" TFT
CJ1M-CPU13
SYSMAC One, 5.7" TFT
CJ1M-CPU13
SYSMAC One, 5.7" TFT
CJ1M-CPU13
SYSMAC One, 5.7" STN
CJ1M-CPU13
SYSMAC One, 5.7" STN
CJ1M-CPU13
DeviceNet
DeviceNet
DeviceNet
DeviceNet
DeviceNet
DeviceNet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
with Ethernet
no Ethernet
Black
NSJ8-TV01B-M3D
Ivory
NSJ8-TV01-M3D
Black
NSJ8-TV00B-M3D
Ivory
NSJ8-TV00-M3D
Black
NSJ5-TQ01B-M3D
Ivory
NSJ5-TQ01-M3D
Black
NSJ5-TQ00B-M3D
Ivory
NSJ5-TQ00-M3D
Black
NSJ5-SQ01B-M3D
Ivory
NSJ5-SQ01-M3D
Black
NSJ5-SQ00B-M3D
Ivory
NSJ5-SQ00-M3D
Function
CJ1G-CPU45H
CJ1M-CPU13
UM capacity
60 Ksteps
20 Ksteps
I/O
1,280 points
640 points
Extended data memory
32 Kwords × 3 banks
–
EM file memory
Yes
–
Maximum number of Expansion Racks
3
1
FB program memory capacity
1024 KB
256 KB
Maximum number of FB definitions
1,024
128
Maximum number of FB instances
2,048
256
Variable table sizes
Note: For the accessories, please refer to page 63
128 KB
64 KB
Item
NSJ8-TV0_-G5D
NSJ8-TV0_-M3D
NSJ5-TQ0_-G5D
NSJ5-SQ0_-G5D
NSJ5-TQ0_-M3D
NSJ5-SQ0_-M3D
Supply voltage
24 VDC
Allowable supply voltage range
20.4 to 27.6 VDC (24 VDC ±15%)
Power consumption
30 W max.
Current consumption
Controller Section Internal 5 V: 500 mA max.
DeviceNet Section Internal 5 V: 200 mA max., External 24 V: 18 mA max.
Inrush current *1
At 24 VAC: 10 A/20 ms max. for cold start at room temperature
Ambient operating temperature
(depending on angle of display surface off horizontal) *2
90° to 60°: 0 to 50°C
60° to 30°: 0 to 45°C
30° to 0°: Use prohibited
Ambient storage temperature
-20 to 60°C
Ambient operating humidity
0 to 40°C: 35% to 85% (with no condensation)
40 to 50°C: 35% to 60% (with no condensation)
Ambient operating environment
No corrosive gases
Insulation resistance
20 MΩ min. (at 100 VDC) between DC external and GR terminals
Dielectric strength
800 VDC for 1 min between DC external and GR terminals, leakage current: 10 mA max.
Noise immunity
2 kV on power supply line (conforming to IEC 61000-4-4)
Vibration resistance (during operation)
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y and Z directions for 80 minutes
Shock resistance (during operation)
147 m/s2, 3 times each in X, Y and Z directions
External
dimensions in
mm (W×H×D)
Without Expansion unit
232×177×73.3
195×142×79
With Expansion unit
HMI
Order Code
SYSMAC One, 8.4" TFT
3
Type
Specifications
SQ0_: 21 W max.
TQ0_: 22 W max.
90° to 30°: 0 to 50°C
30° to 0°: 0 to 40°C
232×177×89.3
195×142×95
Panel output dimensions
220.5+0.500×165.5+0.500 mm (W×H)
Panel thickness: 1.6 to 4.8
184+0.500×131+0.500 mm (W×H)
Panel thickness: 1.6 to 4.8
Grounding
100 Ω or less
Weight
2.0 kg max.
Degree of protection
Front operating panel: Equivalent to IP65F and NEMA4*3
Battery life
5 years (at 25°C)
The SRAM and RTC will be backed up for 5 days after the battery runs low (i.e., after the indicator lights orange). The SRAM and RTC
will be backed up by a super capacitor for 5 minutes after removing the old battery (i.e., after turning ON power after 5 minutes).
International standards
Conforms to cULus and EC Directives.
1.1 kg max.
*1
A delay circuit that charges a capacitor is used to limit the inrush current. If a hot start is performed when the power supply has been OFF only a short period of time, the capacitor will still
be charged and the inrush current specified above will be exceeded by up to approximately five times the specified value. When selecting fuses or breakers for external circuits, allow sufficient
margin in the melting temperatures, detection characteristics, and inrush current.
*2 Display angles off horizontal are as follows:
90°
lay
p
Dis
ce
rfa
su
30°
Horizontal 0°
*3
May not be applicable in locations with long-term exposure to oil.
59
Scalable HMI
NS15/NS12/NS10/NS8
One-touch machine management
The NS-series is our advanced HMI series that covers a large range from 5.7" Monochrome STN to 15" TFT. Easily programmed it offers advanced features like, many
communication possibilities, very good synergy with our PLC's and other devices with
Ladder monitor, Smart Active Parts and proven reliability.
•
•
•
•
•
•
Perfect clarity and fast switching screens
Extremely long backlight life (up to 50,000 hours)
Support all European languages, Asian and Cyrillic
Easy data logging on compact flash
Large Memory size (60 MB)
Support for several non-Omron PLC's
Ordering information
Type
Order Code
TFT, 15’’, 1024 x 768 pixels
with Ethernet
Silver
NS15-TX01S-V2
TFT, 12’’, 800 x 600 pixels
no Ethernet
Black
NS12-TS00B-V2
Ivory
NS12-TS00-V2
Black
NS12-TS01B-V2
Ivory
NS12-TS01-V2
Black
NS10-TV00B-V2
Ivory
NS10-TV00-V2
Black
NS10-TV01B-V2
Ivory
NS10-TV01-V2
Black
NS8-TV00B-V2
Ivory
NS8-TV00-V2
Black
NS8-TV01B-V2
Ivory
NS8-TV01-V2
with Ethernet
TFT, 10'', 640 x 480 pixels
no Ethernet
with Ethernet
TFT, 8.4'', 640 x 480 pixels
no Ethernet
with Ethernet
Note: For the accessories, please refer to page 63
Specifications
Item
NS15
NS12
NS10
NS8
Display type
15 inch colour TFT
12 inch colour TFT
10 inch colour TFT
8 inch colour TFT
Display resolution
1024×768 (XVGA)
800×600 (SVGA)
640×480 (VGA)
Number of colours
256 (32.768 for image data)
Backlight
2×CCFL
Backlight lifetime
Min. 50000 hours
1×CCFL
View angle
Left/right ±85°, Top 70°, Bottom 80° Left/right ±60°, Top 45°, Bottom 75° Left/right ±60°, Top 35°, Bottom 65° Left/right ±65°, Top 50°, Bottom 60°
Touch panel
Analog resistive touch
Matrix resistive touch
Number of functional keys
3
–
Dimensions in mm (H×W×D)
304×405×75.8
241×315×48.5
Weight
4.2 kg max.
2.5 kg max.
Screen data capacity
60 MB
Internal memory
Bit memory: 32,767 bits, Word memory: 32,767 words, Retentative memory: 8,192 bits and 8,192 words.
Memory card interface
1 slot ATA Compact Flash card
Printer connection
PictBridge support
Serial (COM1)
1×RS-232
Serial (COM2)
1×RS-232/422/485
USB Slave
For programming & printing
Ethernet
IEEE 802.3u 10Base-T/100Base-TX
Expansion module
Optional network/video unit
Line voltage
24 VDC ±15%
Power consumption
45 W max.
Battery
CJ1W-BAT01
Battery lifetime
5 years (at 25°C)
Enclosure rating (front side)
IP65F (equivalent to NEMA4)
Obtained standards
UL 1604 Class 1 Diff. 2, cUL, EC Directives
Operating environment
No corrosive gases
Noise immunity
Conforms to IEC61000-4-4, 2 KV (power lines)
Ambiant operating temperature
0 to 50°C*1
Ambiant operating humidity
35% to 85% (0 to 40°C) with no condensation, 35% to 60% (40 to 50°C) with no condensation
*1
60
see manual for details.
2.0 kg max.
1×RS-232
Optional video unit
25 W max.
Scalable HMI
NS5
This series consists of Monochrome models with 16 grey scales and STN/TFT models
with up to 32,768 colours. It is equipped with a USB connection for project download/
upload and the possibility to communicate over Ethernet. One great advantage with
the NS is that you can make use of Omron unique Smart Active Parts (SAP) that save
you time when configuring, commissioning and maintaining your machine. SAP are
pre-programmed, pre-tested visualisation objects with embedded communication
code, bringing 'drag and drop' simplicity to HMI design.
Perfect clarity and fast switching screens
Extremely long backlight life (up to 75,000 hours)
Support all European languages, Asian and Cyrillic
Easy data logging on compact flash
Large Memory size (60 MB)
Support for several non-Omron PLC’s
3
•
•
•
•
•
•
Ordering information
Type
NS5-TQ
Order Code
TFT, 5.7'', 320×240 pixels
no Ethernet
with Ethernet
NS5-SQ
STN, 5.7'', 320×240 pixels
no Ethernet
with Ethernet
NS5-MQ
STN, Monochrome 5.7'',
320×240 pixels
no Ethernet
with Ethernet
Black
NS5-TQ10B-V2
Ivory
NS5-TQ10-V2
Black
NS5-TQ11B-V2
Ivory
NS5-TQ11-V2
Black
NS5-SQ10B-V2
Ivory
NS5-SQ10-V2
Black
NS5-SQ11B-V2
Ivory
NS5-SQ11-V2
Black
NS5-MQ10B-V2
Ivory
NS5-MQ10-V2
Black
NS5-MQ11B-V2
Ivory
NS5-MQ11-V2
Note: For the accessories, please refer to page 63
Specifications
Item
NS5-TQ
NS5-SQ
NS5-MQ
Display type
5.7 inch colour TFT
5.7 inch colour STN
5.7 inch monochrome
Display resolution
340×240 (QVGA)
Number of colours
256 (32.768 for image data)
256 (4.096 for image data)
16 grey scales
Backlight
1×CCFL
Backlight lifetime
Min. 75000 hours
View angle
Left/right ±70°, Top 70°, Bottom 50°
Touch panel
Matrix resistive touch
Number of functional keys
–
Dimensions in mm (H×W×D)
142×195×54
Weight
1.0 kg max.
Screen data capacity
60 MB
Internal memory
Bit memory: 32,767 bits, Word memory: 32,767 words, Retentative memory: 8,192 bits and 8,192 words.
Memory card interface
1 slot ATA Compact Flash card
Printer connection
PictBridge support
Serial (COM1)
1×RS-232
Serial (COM2)
1×RS-232
USB Slave
For programming & printing
Ethernet
IEEE 802.3u 10Base-T/100Base-TX
Expansion module
–
Line voltage
24 VDC ±15%
Power consumption
15 W max.
Battery
CJ1W-BAT01
Battery lifetime
5 years (at 25°C)
Enclosure rating (front side)
IP65F (equivalent to NEMA4)
Obtained standards
UL 1604 Class 1 Diff. 2, cUL, EC Directives
Operating environment
No corrosive gases
Noise immunity
Conforms to IEC61000-4-4, 2 KV (power lines)
Ambiant operating temperature
0 to 50°C*1
Ambiant operating humidity
35% to 85% (0 to 40°C) with no condensation, 35% to 60% (40 to 50°C) with no condensation
*1
Min. 50000 hours
Left/right ±50°, Top 45°, Bottom 50°
HMI
More power, smaller size
Left/right ±45°, Top 20°, Bottom 40°
See manual for details.
61
Scalable HMI
NS5 Handheld
NS5 Handheld, suited for use in harsh
conditions
The NS series has evolved into a mobile format. Based on the standard 5.7” STN
colour version, we can offer a handheld version of the NS series. Offering 10 Function
keys for most used functions and with a protection degree of IP65 it is the product to
use in harsh environment where freedom of movement is needed.
•
•
•
•
10 Function keys, 4 hardwired for inching
Emergency switch on front plus enable switch on back of unit
Well protected against water, IP65
Compact Flash, Serial and USB interface
Ordering information
Type
Order code
NSH5
STN, 5.7", 320×240 pixels
Black
NSH5-SQR10B-V2
Accessories
Type
Order code
Bracket NS handheld protecting emergency button from accidental activation
NSH5-ATT01
Bracket NS handheld for wall mounting
NSH5-ATT02
Cable NS handheld, RS-422, 10m UL
NSH5-422UL-10M
Cable NS handheld, RS-232, 10m UL
NSH5-232UL-10M
Cable NS handheld, RS-232, 3m UL
NSH5-232UL-3M
Specifications
Memory card interface
1 slot ATA Compact Flash card
Serial (COM1)
1×RS-232/RS-422A
USB Slave
For programming
Line voltage
24 VDC ±15%
Power consumption
10 W max.
Battery
CJ1W-BAT01
Battery lifetime
5 years (at 25°C)
Enclosure rating
IP65*1
Obtained standards
UL 1604 Class 1 Diff. 2, cUL, EC Directives, NEMA equivalent
Operating environment
No corrosive gases
Noise immunity
Conforming to IEC 61000-4-4: 2 kV (power supply line)
Ambiant operating temperature
0 to 40°C
Ambiant operating humidity
35% to 85% max. (with no condensation)
Vibration resistance (during operation)
10 to 57 Hz with amplitude of 0.075 mm, 57 to 150 Hz with acceleration of 9.8 m/s2 three minutes each in X, Y, and Z directions
Shock resistance (during operation)
147 m/s2 three times each in X, Y, and Z directions
*1
Drop test
*1
62
see manual for details.
Dropped from 1 m. Conforming to JIS B 3502/IEC61131-2
HMI & Control/Advanced HMI
Accessories NSJ/NS
Ordering information
Type
Description
Cable
Serial programming cable
Order code
PT-to-PLC
Connecting Cable
PT connection: 9 pins
PLC connection: 9 pins
Length: 2 m
XW2Z-200T
Length: 5 m
XW2Z-500T
Accessories
Video input
Inputs: 4 channels NTSC / PAL
NS-CA001
Inputs: 2 channels NTSC / PAL, 1 channel RGB
NS-CA002
Cable to connect NS-CA00_ to Video console unit
HMI
XW2Z-S002
F150-VKP (2 m)
NS-CLK21
RS-422A/485 adapter (50 m)
CJ1W-CIF11
RS-422A adapter (500 m)
Anti-reflection sheets (5 sheets)
NS-AL002
NS12/10
NS12-KBA04
NS8
NS7-KBA04
NS5
NT30-KBA04
NS12/10
NS12-KBA05
NS8
NS7-KBA05
NS5
NT31C-KBA05
NS12/10
NS12-KBA05N
NS8
NS7-KBA05N
NS5
NT31C-KBA05N
Chemical-resistant cover (1 cover)
NS5
NT30-KBA01
Attachment adapter
(NT625C/631/631C series to NS12 series)
NS12-ATT01
(NT625C/631/631C series to NS12 series) Black
NS12-ATT01B
(NT620S/620C/600S series to NS8 series)
NS8-ATT01
(NT600M/600G/610G/612G series to NS8 series)
NS8-ATT02
128 MB
HMC-EF183
256 MB
HMC-EF283
512 MB
HMC-EF583
Anti-reflection protective covers (5 pack)
Transparent protective covers (5 pack)
Memory card
3
F150-VKP (5 m)
Controller link interface unit
Memory card adapter for PC
HMC-AP001
Battery
CJ1W-BAT01
Barcode reader (refer to the catalog for details)
V520-RH21-6
63
Category
Model
Compact HMI
NQ5-SQ
Display 5.7 inch STN Color
CCFL backlight
Resolution 320×240 pixels
Number of colours 256 (4096 for image data)
Memory 8 MB
Communication ports 2×RS-232/RS-422A/RS-485
1×USB Host, 1 x USB Slave
1×option port
Dimensions in mm (HxWxD) 142×195×50
Page 65
Category
Model
Number of F-keys 22
64
320×240 pixels
320×240 pixels
320×240 pixels
Monochrome blue mode, 16 scales
262.000
Monochrome blue mode, 16 scales
4 MB
8 MB
4 MB
2×RS-232/RS-422A/RS-485
1×USB Host, 1 x USB Slave
1×option port
1×RS-232/RS-422A/RS-485
1×USB Host, 1 x USB Slave
1×option port
1×RS-232/RS-422A/RS-485
1×USB Host, 1×USB Slave
1×option port
142×195×50
102×128×44.5
102×128×44.5
65
65
65
NT11
NT2S
LED backlight LCD
6 or 20 depending on model
16×2 lines
Depending on model
Number of screens 250
65,000 (limited by memory)
Page 66
NQ3-MQ
3.8 inch STN Monochrome
LED backlight
Printer connection Yes
Size in mm (HxWxD) 113×218×38.2
NQ3-TQ
3.5 inch TFT Color
LED backlight
Function-key HMI
Type of Display LED backlight LCD
Number of characters 20×4 lines
NQ5-MQ
5.7 inch STN Monochrome
CCFL backlight
6 F-keys 60×109×43
20 F-keys 107×107×43
67
Compact HMI
NQ5/NQ3
Power behind a clear display
The NQ Series comes in different display sizes and each in a color and monochrome
version. All of them display clear and sharp pictures, buttons, text and graphs on a
modern touch screen.
HMI
Clear and bright display
Portrait/Landscape display (NQ5)
USB Host and Slave connections
Easy to use software
Alarming, languages, drivers, etc.
3
•
•
•
•
•
Ordering information
Type
Color STN
Monochrome STN
Order Code
5.7 inch, 320x240 pixels
5.7 inch, 320x240 pixels
No Ethernet
NQ5-SQ000-B
No Ethernet, Portrait model
NQ5-SQ001-B
No Ethernet
NQ5-MQ000-B
No Ethernet, Portrait model
NQ5-MQ001-B
Color TFT
3.5 inch, 320x240 pixels
No Ethernet
NQ3-TQ000-B
Monochrome STN
3.8 inch, 320x240 pixels
No Ethernet
NQ3-MQ000-B
Accessories
Type
Cables
Sotware
Order code
Mini-peripheral port CJ1/CS1/CQM1H/CPM2C PLC, 2 m
NQ-CN221
Serial port RS-232 CJ1/CS1/CP1/CQM1H PLC, 2 m
NT2S-CN232-V1
Serial port RS-232 CJ1/CS1/CP1/CQM1H PLC, 5 m
NT2S-CN235-V1
USB programming cable, 2 m
CP1W-CN221
Serial programming cable, 2 m
NT2S-CN002
NQ-Designer can be downloaded for free from Omron website.
–
Specifications
Item
NQ5-SQ
NQ5-MQ
Display type
5.7 inch Colour STN
5.7 inch Monochrome STN blue mode 3.5 inch Colour TFT
3.8 inch Monochrome STN blue mode
Display resolution
320×240 (QVGA)
Number of colours
256 (4096 for image data)
16 gradations
16 gradations
Backlight
1×CCFL
Backlight lifetime
Min. 30000 hours
Touch panel
Analog resistive touch
Number of functional keys
6
5
Dimensions in mm (H×W×D)
142×195×50
102×128×44.5
Weight
0.4 kg max.
Screen data capacity
8 MB
Internal memory
Bit, Word and Retentive memory
Serial (COM1)
1×RS-232/422/485
Serial (COM2)
1×RS-232
USB Slave
For programming
USB Host
For USB stick file transfer
Expansion module
Optional network unit
Line voltage
24 VDC ±15%
Power consumption
15 W max.
Battery
NQ-BAT01 (3 V coin battery)
Battery lifetime
5 years (at 25°C)
Enclosure rating (front side)
IP65 (equivalent to NEMA4)
Obtained standards
CE, cUL, EC Directives
Operating environment
No corrosive gases
Ambiant operating temperature
0 to 50°C*1
Ambiant operating humidity
10-85% RH, no condensation
*1
NQ3-TQ
256 (32.768 for image data)
NQ3-MQ
LED
4 MB
8 MB
4 MB
–
–
5 W max.
see manual for details.
65
Function-key HMI
NT11
HMI with four text lines and 22 F-keys
The NT11 is a Function key HMI with four text lines that can each hold up to
20 characters. It has a parallel printer connection next to a serial port for connection
to a PLC. It has a LED backlight that has a life expectancy of at least 50.000 hours.
•
•
•
•
•
Easy programming software.
Small size and installation depth.
Customisable F-Keys
Printer connection.
Cost effective solution.
Ordering information
Type
STN monochrome
Order code
Ten-key type
Ivory
NT11-SF121-EV1
Black
NT11-SF121B-EV1
Accessories
Type
Description
Cables
For screen transfer
For PLC connection
Options
Reflection Protective Sheets
Order code
XW2Z-S002
PT: 9-pin
PLC: 9-pin
Cable length: 2 m
XW2Z-200T
Cable length: 5 m
XW2Z-500T
PT: 9-pin
PLC: Mini-peripheral
Cable length: 2 m
NT-CN221
Replacement for ivory type (10 sheets)
NT11-SF121-EV1
Replacement for black type (10 sheets)
NT11-SF121B-EV1
Software
Type
Order code
NTST Version 4.8
NTZJCAT1EV4
Upgrade NTST Version 4.8
NTZJCAT1EV4S
Specifications
Size in mm (HxWxD)
113×218×38.2
Effective display area
100×40mm (160×64 pixels)
Line voltage
24 VDC ±15%
Function keys
22 keys
Touch panel
–
Obtained standards
CE, cULus
No. of display characters
(standard characters)
20 characters × 4 lines
No. of registered screens
250
Screen data capacity (standard)
32 KB
Expansion memory
–
Memory card interface
–
Printer connection
Supported
Backlight life
50,000 hours average
66
Function-key HMI
NT2S
HMI with two text lines, 6 or 20 F-keys
and up to two serial ports
The NT2S is the smallest HMI that we can offer you. It is based on a 16 × 2 lines
LCD display with 6 or 20 Function keys. It offers IP65 protection, an optional RTC and
printer connection.
HMI
Easy and free programming software.
Small size and installation depth.
Real Time Clock (depending on model).
Printer connection (depending on model).
Cost effective solution.
3
•
•
•
•
•
Ordering information
Type
STN monochrome
Order code
Programmable
6-key type, Black
NT2S-SF121B-EV2
NT2S-SF122B-EV2
PLC controlled
Programmable
NT2S-SF123B-EV2
20-key type, Black
PLC controlled
NT2S-SF125B-E
NT2S-SF126B-E
NT2S-SF127B-E
Accessories
Type
Description
Order code
NT2S-SF121/125 and NT3S
peripheral port CPM series except CPM2C, 2 m
NT2S-CN212-V1
NT2S-SF121/125 and NT3S
peripheral port CPM series except CPM2C, 5 m
NT2S-CN215-V1
NT2S-SF122/SF123/SF126/SF127
peripheral port CPM series except CPM2C, 2 m
NT2S-CN222-V1
NT2S-SF122/SF123/SF126/SF127
peripheral port CPM series except CPM2C, 5 m
NT2S-CN225-V2
NT2S-SF121/125 and NT3S
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
NT2S-CN223-V2
NT2S-SF122/SF123/SF126/SF127
mini-peripheral port CJ1/CS1 and CPM2C series, 2 m
NT2S-CN224-V1
All NT2S and NT3S models
serial programming cable, 2 m
NT2S-CN002
Software
Type
Order code
This software is provided free of charge and features Windows fonts, a Multi language import/export utility, a character map to design your own characters
and can be used to place bitmaps in your application.
NTXS
Specifications
Size in mm (H×W×D)
60×109×43 (6 F-keys), 107×107×43 (20 F-keys)
Effective display area
56×11 mm
Line voltage
24 VDC ±10%
Touch panel
–
Obtained standards
CE, cULus
No. of display characters (standard characters)
16 characters x 2 lines
No. of registered screens
65,000 max.
Screen data capacity (standard)
24 KB in Programmable models
Expansion memory
–
Memory card interface
–
Internal memory
1 kWords data, 1 kWords retentative memory
Printer connection
Supported
Multi-Vendor support
Supported for several non-Omron PLCs. *1
Backlight life
LED, min. 50,000 hours
*1
Please contact Omron for a list of available drivers.