EMC Cloud Tiering Appliance and Cloud Tiering
EMC® Cloud Tiering Appliance
and Cloud Tiering Appliance/VE
Version 12.0
Getting Started Guide
P/N 300-005-094
Rev 24
Copyright © 2016-2017 Dell Inc. or its subsidiaries All rights reserved.
Published July 2017
Dell believes the information in this publication is accurate as of its publication date. The information is subject to
change without notice.
THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS-IS.“ DELL MAKES NO REPRESENTATIONS OR
WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND
SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. USE, COPYING, AND DISTRIBUTION OF ANY DELL SOFTWARE DESCRIBED IN THIS
PUBLICATION REQUIRES AN APPLICABLE SOFTWARE LICENSE.
Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the
property of their respective owners. Published in the USA.
Dell EMC
Hopkinton, Massachusetts 01748-9103
1-508-435-1000 In North America 1-866-464-7381
http://www.DellEMC.com
Error! No text of specified style in document.Error! No text
of specified style in document.
1
Contents
Contents
Chapter 1
Introduction ........................................................................... 11
Overview of the Cloud Tiering Appliance ............................................................ 12
File tiering and migration .............................................................................. 12
Block archiving ............................................................................................. 13
Cloud Tiering Appliance/VE (CTA/VE) ............................................................ 13
High Availability for CTA and CTA/VE ............................................................. 13
CTA implementation with VNX or Unity file primary storage ................................ 14
CTA implementation with NetApp primary storage ............................................. 15
CTA implementation with Unity block snapshots ............................................... 17
CTA and CTA/VE tasks........................................................................................ 17
Using CTA and CTA/VE ....................................................................................... 19
Chapter 2
Cloud Tiering Appliance Hardware and Port Configurations ..... 21
Cloud Tiering Appliance 12 qualified hardware .................................................. 22
Cloud Tiering Appliance High Availability types ............................................. 24
Contents of the appliance ............................................................................. 25
Appliance diagrams ........................................................................................... 25
Port details ........................................................................................................ 26
Chapter 3
Installing the Cloud Tiering Appliance ..................................... 27
Appliance setup ................................................................................................ 28
Installing the virtual edition ............................................................................... 28
CTA and CTA/VE for high availability .................................................................. 29
High availability with VNX or Unity primary storage ....................................... 30
High availability with NetApp primary storage ............................................... 30
Network console management for Gen 8 models ............................................... 31
Using CTA CLI commands .............................................................................. 32
Rebooting the system ................................................................................... 32
Performing a CD clean install on the appliance .................................................. 32
Performing a CD clean install on a generic server ............................................... 33
Adding the CTA serial number ............................................................................ 34
Configuring CTA ................................................................................................. 34
Configure the CTA network ............................................................................ 35
Configure the hostname, domain, and DNS server ........................................ 36
Configure iSCSI IQN targets (Unity block archiving and restore only) ............. 36
2
2
EMC® Cloud Tiering Appliance Getting Started Guide
Contents
Update the hosts file .................................................................................... 37
File Encryption ................................................................................................... 37
Enabling keystore replication ........................................................................ 37
Configuring and using file encryption ............................................................ 37
Graphical user interface..................................................................................... 38
Command line interface..................................................................................... 39
Chapter 4
Deploying the Cloud Tiering Appliance.................................... 41
Deployment process for archiving ...................................................................... 42
Step 1: Set up CTA ........................................................................................ 43
Step 2: Configure the archive environment ................................................... 43
Step 3: Configure the destination ................................................................. 43
Step 4: Define policies .................................................................................. 44
Step 5: Create a task..................................................................................... 44
Step 6: Run the simulation task (optional) .................................................... 44
Step 7: Run the policy task ........................................................................... 44
Supported platforms ......................................................................................... 44
Deploying CTA with VNX..................................................................................... 45
Prerequisites for using VNX as a file migration source or destination ............ 46
Prerequisites for VNX as an archive source ................................................... 46
Adding VNX to the CTA configuration............................................................. 47
Configure name resolution for archiving........................................................ 50
Configuring VNX to Centera or cloud archiving on the CTA ............................. 51
Prerequisite tasks on the VNX Control Station for file migration or archiving . 52
Deploying CTA with NetApp................................................................................ 57
Prerequisites for using NetApp as a file migration source .............................. 57
Prerequisites for using NetApp as an archiving source .................................. 57
vFiler configuration ....................................................................................... 60
Configuring NetApp archiving on the CTA ...................................................... 60
Adding NetApp filer to the CTA configuration................................................. 60
Verify the FPolicy configuration for CTA ......................................................... 63
Deploying CTA with a VNXe ................................................................................ 64
Prerequisites for using VNXe as a file migration destination.......................... 64
Adding VNXe to the CTA configuration ........................................................... 64
Deploying CTA with Unity ................................................................................... 65
Prerequisites for Unity as an archive source .................................................. 65
Configure name resolution for archiving........................................................ 66
Configuring Unity to cloud archiving on the CTA ............................................ 66
Adding a Unity file server to the CTA configuration ........................................ 67
Adding a Unity block server to the CTA configuration .................................... 68
Deploying CTA with Virtustream ......................................................................... 70
Deploying CTA with a Windows server ................................................................ 71
Adding a Windows server to the CTA configuration........................................ 72
EMC® Cloud Tiering Appliance Getting Started Guide
3
3
Contents
Installing the EMWS copy agent for CTA ........................................................ 72
Installing and running LGDUP ....................................................................... 73
Deploying CTA with Isilon .................................................................................. 74
Prerequisite tasks when using Isilon as a CIFS share destination .................. 74
Prerequisite tasks when using Isilon as an NFS export destination ............... 76
Prerequisite task when using Isilon as a file migration destination ............... 76
Adding Isilon to the CTA configuration .......................................................... 77
CTA and Isilon SmartConnect ........................................................................ 78
Deploying the CTA with Data Domain ................................................................. 80
Configuring a NAS-based repository .................................................................. 81
Deploying CTA with Amazon S3 ......................................................................... 82
Adding Amazon S3 to the CTA configuration ................................................. 82
Deploying CTA with Atmos ................................................................................. 83
Adding Atmos to the CTA configuration ......................................................... 83
Installing the SSL certificate on the CTA ........................................................ 84
Deploying CTA with Azure .................................................................................. 85
Adding Azure to the CTA configuration .......................................................... 85
Deploying CTA with Centera ............................................................................... 86
Deploying CTA with ECS ..................................................................................... 86
Adding ECS to the CTA configuration ............................................................. 87
Chapter 5
Maintaining the Cloud Tiering Appliance ................................. 89
Importing a file list archive ................................................................................ 90
Adding the primary servers ........................................................................... 90
Configure name resolution for archiving........................................................ 90
Configuring Unity to cloud archiving on the CTA ............................................ 91
Configuring the import provider .................................................................... 92
Configuring the import task........................................................................... 92
Importing the file list..................................................................................... 93
Validating the import file .............................................................................. 94
Backing up the configuration ............................................................................. 94
Creating a backup dump ............................................................................... 95
Restoring a backup dump ............................................................................. 95
Encryption Key restore in case of catastrophic failures ....................................... 97
Maintaining the database .................................................................................. 98
Checking database size and disk capacity .................................................... 98
Performing database maintenance ............................................................... 98
Migrating from CTA to CTA/VE ............................................................................ 99
Shutting down and restarting the appliance .................................................... 100
Chapter 6
Cloud Tiering Appliance System Settings .............................. 101
Security hardening .......................................................................................... 102
Single security database ............................................................................. 102
4
4
EMC® Cloud Tiering Appliance Getting Started Guide
Contents
Disable root logins ...................................................................................... 104
Strengthen passwords ................................................................................ 104
Age passwords ........................................................................................... 105
Configuring the GUI access method ................................................................. 105
STIG hardening ................................................................................................ 105
Enabling STIG hardening ............................................................................. 105
Disabling STIG hardening............................................................................ 106
LDAP client configuration................................................................................. 107
Global LDAP settings................................................................................... 107
LDAP authentication ................................................................................... 108
Configuring LDAP settings ........................................................................... 109
Certificate management................................................................................... 111
Appliance mail delivery settings ...................................................................... 111
Log settings ..................................................................................................... 112
Configuring log rotation .............................................................................. 112
Configuring SCP of rotated log files ............................................................. 112
Configuring alerts ............................................................................................ 114
Configuring email alerts .............................................................................. 114
Configuring SNMP alerts ............................................................................. 115
Enabling SNMP polling................................................................................ 116
System command accounting .......................................................................... 116
Tracking user command history .................................................................. 117
Tracking user login history .......................................................................... 117
Tracking daemon command history ............................................................ 117
Windows domain user ..................................................................................... 118
Creating a Windows domain user ................................................................ 118
Adding an admin user to the local administrator group ............................... 118
Configuring Windows for Kerberos .............................................................. 119
Configuring Windows 2008 for NTLM .......................................................... 119
SID translator .................................................................................................. 120
Installing the SID translator ........................................................................ 120
Creating the SID translation file .................................................................. 121
Uploading the SID translation file ............................................................... 121
Deleting a SID translation file...................................................................... 122
Appendix A Network topology scenarios ................................................. 123
Advanced network topologies.......................................................................... 124
Configuring the CTA with bonding ............................................................... 124
Configuring the CTA with two subnets ......................................................... 125
Configuring the CTA with more than two subnets ........................................ 126
VLAN tagging modes for the CTA/VE ................................................................ 127
ESX Server virtual switch tagging ................................................................ 127
ESX Server virtual guest tagging .................................................................. 128
EMC® Cloud Tiering Appliance Getting Started Guide
5
5
Contents
Appendix B Alerts................................................................................... 131
Supported SNMP traps .................................................................................... 132
CTA alerts ........................................................................................................ 133
6
6
EMC® Cloud Tiering Appliance Getting Started Guide
Introduction
Figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
VNX or Unity file implementation ........................................................ 14
NetApp implementation ..................................................................... 15
Unity block implementation................................................................ 17
Rear view of Gen 8 appliance.............................................................. 25
Front view of Gen 8 appliance with bezel removed.............................. 26
Cloud Tiering Appliance deployment process ..................................... 42
EMC® Cloud Tiering Appliance Getting Started Guide
7
7
Tables
Tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
8
8
Dell R630 G13 hardware qualified for CTA .......................................... 22
CTA-HA that is based on Dell R630 G13 .............................................. 22
CTA that is based on Intel C1U ............................................................ 23
CTA-HA that is based on Intel C1U ...................................................... 24
VMware ESX Server interoperability .................................................... 28
Supported platform matrix for archiving ............................................. 44
Supported platform matrix for file migration ....................................... 45
VNX deployment checklist .................................................................. 45
NetApp deployment checklist ............................................................. 57
Supported SNMP traps ..................................................................... 132
CTA alerts ......................................................................................... 133
EMC® Cloud Tiering Appliance Getting Started Guide
Preface
Preface
As part of an effort to improve its product lines, EMC periodically releases revisions of
its software and hardware. Therefore, some functions described in this document
might not be supported by all versions of the software or hardware currently in use.
The product release notes provide the most up-to-date information on product
features. Contact your EMC technical support professional if a product does not
function properly or does not function as described in this document.
Audience
This document is part of the Cloud Tiering Appliance and Cloud Tiering Appliance/VE
documentation set. The documentation is intended for use by:
•
Storage management administrators who are new to the Cloud Tiering
Appliance and Cloud Tiering Appliance/VE.
•
Existing customers who are new to version 12.0.
Related documents
The following publications provide additional information:
•
Cloud Tiering Appliance White Papers — Provide best practices for configuring
specific file servers and for conducting specific tasks.
•
Cloud Tiering Appliance and Cloud Tiering Appliance/VE online help —
Provides detailed reference information on the graphical user interface.
•
Cloud Tiering Appliance Upgrade Guide — Provides instructions on upgrading
to the current CTA version.
•
Cloud Tiering Appliance and Cloud Tiering Appliance/VE Release Notes —
Provides an overview of new features and lists any limitations.
•
CTA man pages — Provide detailed command-line help, as well as overview
information. A good starting point is: man rffm. PDFs of all man pages are
available from:
/opt/rainfinity/filemanagement/doc
EMC® Cloud Tiering Appliance Getting Started Guide
9
9
Preface
Where to get help
Support, product, and licensing information can be obtained as follows:
For information about products, software updates, licensing, service, and product
documentation, go to Online Support (registration required) at:
https://Support.EMC.com. After logging in, locate the appropriate Support by Product
page.
For technical support and service requests, go to Online Support at:
https://Support.EMC.com. After logging in, locate Create a service request. To open a
service request, you must have a valid support agreement. Contact your Sales
Representative for details about obtaining a valid support agreement or to answer
any questions about your account.
10
10
EMC® Cloud Tiering Appliance Getting Started Guide
Chapter 1
Introduction
This chapter includes the following sections:
Overview of the Cloud Tiering Appliance ..................................................... 12
CTA implementation with VNX or Unity file primary storage.......................... 14
CTA implementation with NetApp primary storage....................................... 15
CTA implementation with Unity block snapshots......................................... 17
CTA and CTA/VE tasks ................................................................................ 17
Using CTA and CTA/VE ............................................................................... 19
EMC® Cloud Tiering Appliance Getting Started Guide
11
11
Overview of the Cloud Tiering Appliance
The Cloud Tiering Appliance (CTA) provides a full range of features including the
ability to:
•
Tier or archive and recall file data
•
Migrate files
•
Perform orphan file management
•
Perform stub file recovery
•
Archive and restore block data (Unity only)
•
Simulate the potential effect of policies before taking action
The CTA software also includes a robust reporting interface that provides valuable
insight into the efficacy of archiving policies.
Depending on the type of task, CTA supports a variety of platforms:
•
Supported platform matrix for archiving in Table 6.
•
Supported platform matrix for file migration in Table 7.
File tiering and migration
CTA includes technology that optimizes primary file storage by automatically moving
inactive files based on policies to secondary storage. Secondary storage could be
lower cost drives, such as NL-SAS or SATA drives, or to other platforms, including
public and private clouds. Files that are moved appear as if they are on primary
storage. File tiering dramatically improves storage efficiency, and backup and restore
time. File archiving onto storage with WORM functionality can support additional
business requirements such as compliance and retention.
As an example, a CTA may be configured to locate all NAS data that has not been
accessed in one year, and move that data to secondary storage. For each file it
moves, the appliance will leave behind a small space-saving stub file that points to
the real data on the secondary storage device. When a user tries to access the data in
its original location on the primary NAS, the user will be transparently provided with
the actual data that the stub points to, from secondary storage.
If a multi-tier policy is used, the appliance may be configured to move files from a
secondary storage device tier to a tertiary storage device tier. This can be particularly
useful in cases where the secondary storage device represents a tier that is smaller,
faster, and more expensive to maintain than a larger, slower, and cheaper storage
used in the tertiary tier. Once the files are moved, the space-saving stub file on the
primary NAS tier would be updated to point to the data’s new location on the tertiary
storage tier.
In addition to tiering data from primary to secondary storage and leaving a stub
behind on the primary server for recall later, the CTA can also permanently migrate
files from a source to a destination without leaving a stub.
12
12
EMC® Cloud Tiering Appliance Getting Started Guide
Block archiving
CTA leverages the Unity snapshot differentials API in order to efficiently take backups
of block data to the cloud. You can archive a full copy of a LUN, consistency group or
thin clone to the cloud and perform incremental archives using subsequent
snapshots. You can also customize the Common Base Frequency attribute in the CTA
management GUI to decide the spacing of full copies.
Block snapshots that have been archived to the cloud, are independent of the base
resource on the source and are not altered by the archiving. Instead they share blocks
with the baseline snapshot established by CTA. Once the LUN/snapshot is archived,
it can be deleted in the source array to free up space.
Cloud Tiering Appliance/VE (CTA/VE)
The Cloud Tiering Appliance/VE (CTA/VE) is a VMware virtual appliance installed on a
VMware ESX/ESXi Server. CTA/VE is provided in an industry-standard virtual
appliance distribution that consists of an Open Virtualization Format (OVF) and
Virtual Machine Disk (VMDK) file.
Virtual appliances are prebuilt software solutions, comprised of one or more virtual
machines that are packaged, updated, maintained, and managed as a unit. Unlike a
traditional hardware appliance, these software appliances allow customers to
acquire, deploy, and manage pre-integrated solution stacks more quickly and easily.
High Availability for CTA and CTA/VE
The Cloud Tiering Appliance for High Availability (CTA-HA) and the Cloud Tiering
Appliance/VE for High Availability (CTA/VE-HA) complement the existing CTA or
CTA/VE by ensuring that tiered files can always be recalled, even in the event that the
primary appliance goes down. This ensures complete transparency and nondisruptive
service for clients. The high availability appliance is not used for any purpose other
than recall. For example, it does not perform archiving or orphan file management,
nor does it have a graphical user interface.
The CTA-HA is a dedicated machine that runs the VNX, Unity or NetApp callback
agents and is delivered preloaded with software. Installation instructions for the CTAHA differ slightly from the CTA. The CTA/VE-HA provides the same functionality as the
CTA-HA but is installed on a virtual appliance like the CTA/VE. A virtual HA can be
deployed with a physical CTA and vice versa. In this way, a network with a physical
CTA does not need a second piece of hardware to provide HA, it can use a CTA/VE-HA.
When a high-availability appliance is deployed alongside a CTA or CTA/VE, the
underlying APIs of VNX, Unity NAS servers and NetApp file servers are leveraged to
create a highly available environment for data recall. The VNX, Unity and NetApp
implementations differ, as shown in Figure 1 and Figure 2.
High-availability appliances are not needed in all tiered source and destination
combinations. The CTA and CTA/VE Interoperability Matrix provides more details.
EMC® Cloud Tiering Appliance Getting Started Guide
13
13
CTA implementation with VNX or Unity file primary storage
Figure 1 shows the recall architecture of CTA implementation with VNX, or Unity files:
Figure 1.
VNX or Unity file implementation
Circled numbers correspond to the following steps that illustrate the recall process in
the VNX or Unity implementation:
Clients send read/write operations for files that have been archived. These stub
files contain information about where the file has been archived to. These
operations are intercepted by the DHSM layer on the VNX or Unity system prior to
being serviced from the file system.
If the file has been archived to EMC Centera® or cloud storage (such as EMC
Atmos™, Amazon S3, ECS/S3, or Microsoft Azure), the VNX or Unity resolves the
fully qualified domain name (FQDN) stored in the stub file to the IP address of the
CTA or CTA-HA.
The storage system then uses HTTP to read the archived data from the appliance,
which in turn reads it from cloud storage by using the platform API. If an
appliance does not respond to the HTTP read requests, the VNX or Unity system
uses an alternate IP address of another appliance configured in DNS. Every
14
14
EMC® Cloud Tiering Appliance Getting Started Guide
callback server (CTA, CTA-HA, CTA/VE, or CTA/VE-HA) has its IP address
associated with a single hostname in DNS. The FQDN uses that hostname, which
may have multiple IP addresses associated with it.
If the file has been archived to an NFS or CIFS repository, the VNX opens a
connection to the repository and reads back the data.
The VNX responds to the client operation as usual if the recall was successful, or
the client receives a message that the file cannot be opened if the recall fails.
Note
When VNX data has been archived to a VNX, VNXe, NetApp, Data
Domain, Isilon, or Microsoft Windows repository, the CTA or CTA/VE is
not involved in the recall process, and a high availability appliance is
not used.
CTA implementation with NetApp primary storage
Figure 2 shows the recall architecture of CTA implementation with a NetApp system:
Figure 2.
NetApp implementation
Circled numbers correspond to the following steps that illustrate the archive and
recall process in the NetApp implementation:
Clients send read/write operations for files that have been archived. These
operations are intercepted by the FPolicy layer on the NetApp prior to being
serviced from the Write Anywhere File Layout (WAFL) filesystem.
EMC® Cloud Tiering Appliance Getting Started Guide
15
15
The NetApp is configured with the following groups:
a.
A primary group of callback servers, such as a CTA and possibly one or
more CTA-HAs.
b.
A secondary group, such as one or more physical or virtual HAs.
The NetApp will send FPolicy callbacks to servers registered in the primary group
in round-robin fashion. If a server does not reply to the callback, it is removed
from its group. If there are no servers in the primary group, the callbacks are
distributed in a round-robin fashion among the servers in the secondary group.
For CTA/VE, the primary group of callback servers consists of virtual machines
such as a CTA/VE and possibly one or more CTA/VE-HAs. The secondary group
consists of one or more CTA/VE-HAs.
The appliance connects to the filer by using CIFS to read the contents of the stub
file. The stub file points to where the file data is stored. The appliance then
connects to the NFS repository, CIFS repository, Centera, or cloud storage where
the data was archived. It then reads the data by using the native protocol and the
file data is written back to the NetApp.
The filer responds to the client operation as usual if the recall was successful, or
with an "access denied" message if the recall failed.
Note
16
16
It is a requirement that the software versions of all the appliances match. For
example, do not deploy a configuration with a CTA that is running version 8.0
and a CTA-HA that is running version 7.4. While the software does not perform
any explicit checks to ensure the versions are compatible, the running of
different software versions has not been tested and may result in unexpected
behavior.
EMC® Cloud Tiering Appliance Getting Started Guide
CTA implementation with Unity block snapshots
Figure 3 shows the architecture of CTA implementation with Unity block snapshots.
Figure 3.
Unity block implementation
CTA and CTA/VE tasks
The CTA or CTA/VE may be used to run several different tasks:
•
Tiering or archiving
•
Deleting orphaned data
•
Auxiliary tasks, such as stub scanning and backup
•
Migration tasks such as repository migration and file migration
For archiving, deleting and migrating files, the software leverages a policy engine to
select the files. Users can combine and evaluate multiple rules together in a single
policy. Several rule types are available.
Before running the archive, delete, or migration task, the running of a simulation
allows administrators to review real-time results without executing the task. The
results will return:
•
Aggregated summary of total files matched
•
Total bytes potentially archived
Also, if an optional detailed simulation is run, a list of files that match the policy is
saved on the disk for review.
EMC® Cloud Tiering Appliance Getting Started Guide
17
17
Run a simulation to gain insight into the efficiency of a task before running the task.
This practice is notably important for the delete tasks, since these tasks remove data.
A report displays results of the task.
Archive tasks may be one of three types:
•
Archive (with policy) — Archives regular (non-stub) files. Files are selected for
archiving based on the archive policy.
•
Multi-tier (with policy) — For this archiving task, regular and stub files are
evaluated with the multi-tier policy.
•
a.
If a regular file matches the policy, it is archived.
b.
If a stub file matches the policy, archived data is moved to a different
storage tier and the stub is updated to point to the new location.
Multi-tier stub (with policy) — For this archiving task, only stub files are
evaluated with the multi-tier stub policy. If a stub file matches the policy,
archived data is moved to a different storage tier and the stub is updated to
point to the new location. Otherwise, the archived data remains in the current
storage tier.
In addition, CTA can perform an archive task on an imported list of files.
Delete tasks may be one of two types:
•
Delete orphan with policy — Deletes orphans on secondary storage that
match the delete orphans policy.
•
Delete stub with policy — The delete stub task deletes stubs that match the
delete stubs policy. Stubs on primary storage and files on the second tier that
are no longer under retention or that were defined without any retention
period are automatically deleted.
Auxiliary tasks are:
•
Scan stubs — When a file is archived, a stub file remains on the source and an
entry is added to the CTA database, and maps the name and location of the
archived file to its stub. The stub scanning task tracks the stub file
information. When a stub has not been detected on a CIFS share or NFS
export for 30 or more days, the corresponding archived file is designated as
an orphan. If stub files are moved from the original archive location to another
location, manually run a stub scanner task on the new location so that the
CTA does not consider these files orphans.
•
Backup — The backup task performs periodic backups of the CTA
configuration and database. Schedule backup tasks as part of a regular
maintenance program. Only one backup task may be scheduled.
Migration tasks are:
•
18
18
Repository Migration — Repository migration moves archived files from one
storage tier to another storage tier. Migration can be to a NAS repository, to a
Centera, or to an on-premise or service provider cloud such as Atmos or
Amazon S3. All stub files that point to this data will be updated to point to the
new location.
EMC® Cloud Tiering Appliance Getting Started Guide
•
File Migration (with policy) — The file migration task moves files from a
primary to a secondary server that are defined as the source and destination
in the task definition. The task evaluates both normal and stub files based on
the migrate file policy with a resulting action of either migrate or don’t
migrate.
The CTA software also has the capability to recover stub files accidentally deleted by
client systems. It can even recover prior versions of files archived to any secondary
storage destination.
Note
Do not duplicate stubs, because CTA does not support them. Repository
migration and Orphan deletion tasks will randomly detect and manage the
first occurrence of a stub, and will ignore the duplicates. This can lead to data
unavailability and data loss.
Using CTA and CTA/VE
Once the appliance has been deployed on the network, the administrator can
manage data through the CTA or CTA/VE graphical user interface (GUI) or command
line interface (CLI). Graphical user interface explains how to invoke the GUI. Online
help documents all GUI pages.
Technical system details that are not related to the GUI, but are required to configure
the CTA or CTA/VE, are provided in the following chapters and appendixes:
•
Chapter 4, Deploying the Cloud Tiering Appliance
•
Chapter 5, Maintaining the Cloud Tiering Appliance
•
Chapter 6, Cloud Tiering Appliance System Settings
•
Appendix A, Network Topology scenarios
Except where expressly stated otherwise, all sections of this guide apply to both the
CTA and CTA/VE.
EMC® Cloud Tiering Appliance Getting Started Guide
19
19
Chapter 2
Cloud Tiering Appliance Hardware and
Port Configurations
This chapter contains the following sections:
Cloud Tiering Appliance 12 qualified hardware ........................................... 22
Appliance diagrams ................................................................................... 25
Port details ............................................................................................. 26
EMC® Cloud Tiering Appliance Getting Started Guide
21
21
Cloud Tiering Appliance 12 qualified hardware
•
Dell R630 G13 server is qualified with CTA 12. User must perform a CD clean
install of CTA and CTA-HA after purchasing these servers.
•
Table 1 lists the Gen 13 hardware configuration of the Dell R630 server
qualified for CTA
Table 1.
Component
Dell Power Edge R630 G13
Chassis
Chassis with up to 8, 2.5" hard drives, 3 PCIe slots
Size
1U
Power
Dual, Hot-plug, Redundant Power Supply (1+1) 750W
CPUs
Single Intel Xeon E5-2620 v3 2.4GHz. 15M Cache
Disks
Four 1.2TB 10K RPM SAS 12Gbps 2.5" Hot-plug hard drives in a
RAID-1 configuration with two hot spares. SATA or Nearline
SAS hard drives are an option.
RAID controller
PERC H730 Integrated RAID Controller, 1GB Cache
CD-ROM
Internal SATA DVD-ROM that can read CD or DVD material for
system install or upgrade.
Memory
2400-MHz, 16GB
Network
interfaces
Two 10/100/1000 Mbps and two 100 Mbps/1 Gbps/10 Gbp
VGA
Two 15-pin B10VGA ports on the front and back panels to
connect the system to a VGA display for system console.
Keyboard
connector
Two 4-pin, USB 2.0-compliant ports on the front and back
panels to connect a standard USB keyboard for system
console.
Mouse
connector
Two 4-pin, USB 2.0-compliant ports on the front and back
panels to connect a standard USB mouse for system console.
Serial port
One standard DB9 serial connector on the back panel for a
serial-terminal system.
•
Table 2 lists the Gen 13 hardware configuration of the Dell R630 server
qualified for CTA-HA
Table 2.
22
22
Dell R630 G13 hardware qualified for CTA
CTA-HA that is based on Dell R630 G13
Component
Dell Power Edge R630 G13
Chassis
Chassis with up to 8, 2.5" hard drives, 3 PCIe slots
Size
1U
Power
Dual, Hot-plug, Redundant Power Supply (1+1) 750W
EMC® Cloud Tiering Appliance Getting Started Guide
Component
Dell Power Edge R630 G13
CPUs
Single Intel Xeon E5-2620 v3 2.4GHz. 15M Cache
Disks
Two 1.2TB 10K RPM SAS 12Gbps 2.5" Hot-plug hard drives in a
RAID-1 configuration. SATA or Nearline SAS hard drives are an
option.
RAID controller
PERC H730 Integrated RAID Controller, 1GB Cache
CD-ROM
Internal SATA DVD-ROM that can read CD or DVD material for
system install or upgrade.
Memory
2400-MHz, 8GB Total
Network
interfaces
Two 10/100/1000 Mbps and two 100 Mbps/1 Gbps/10 Gbp
VGA
Two 15-pin B10VGA ports on the front and back panels to
connect the system to a VGA display for system console.
Keyboard
connector
Two 4-pin, USB 2.0-compliant ports on the front and back
panels to connect a standard USB keyboard for system
console.
Mouse
connector
Two 4-pin, USB 2.0-compliant ports on the front and back
panels to connect a standard USB mouse for system console.
Serial port
One standard DB9 serial connector on the back panel for a
serial-terminal system.
When performing CTA/CTA-HA bare metal installations, please refer to the
corresponding documentation on the vendor’s website for hardware comparable to
the Dell R630.
Cloud Tiering Appliance type
The CTA8-APL hardware appliance based on Intel C1U hardware is bundled with VNX.
•
Table 3 lists the Gen 8 hardware configuration for the CTA that is based on the
Intel C1U hardware.
Table 3.
CTA that is based on Intel C1U
Component
CTA8-APL
Chassis
The appliance is based on Intel C1U Kylin node hardware.
Size
1U form factor.
Power
Dual 750 watt. Item (b) in Figure 4. Power button and
identification light is item (f) in Figure 5.
CPUs
Dual Intel Sandy Bridge Six Core AES 256 HW encryption.
Disks
Four 900 GB 2.5-inch, 10K RPM hard drives in a RAID-5
configuration. Items (b) through (e) in Figure 5.
RAID controller
Intel RMS25CB080 (Condado Beach).
EMC® Cloud Tiering Appliance Getting Started Guide
23
23
Component
CTA8-APL
CD-ROM
Read-only DVD that can read CD or DVD material for system
upgrades. Item (a) in Figure 5.
Memory
16 GB
Network
interfaces
Four on-board gigabit 10/100/1000 TX Ethernet copper ports
with RJ45 connectors. Item (e).
Two 10GbE optical ports provided with the Intel mezzanine
module. Item (g).
One dedicated management port. Item (f).
All items in Figure 4.
VGA
Standard VGA video connector for a system console. Item (a) in
Figure 5.
Keyboard
connector
Standard USB keyboard connector for a system console. Item
(d) in Figure 5.
Mouse
connector
Standard USB mouse connector for a system console. Item (c)
in Figure 5.
Cloud Tiering Appliance High Availability types
CTA8-HA-APL based on Intel C1U hardware is bundled with VNX. Table 4 lists the Gen
8 hardware configuration for the CTA-HA that is based on the Intel C1U hardware.
Table 4.
CTA-HA that is based on Intel C1U
Component
CTA8-HA-APL
Chassis
The appliance is based on Intel C1U Kylin node hardware.
Size
1U form factor.
Power
Dual 750 watt.
CPU
Single Intel Sandy Bridge Six Core AES 256 HW encryption.
Disks
Two 900 GB 2.5-inch, 10K RPM hard drives in a RAID-1
configuration. Items (b) and (c) in Error! Reference source not
found.
RAID controller
Intel RMS25CB080 (Condado Beach).
CD-ROM
Read-only DVD that can read CD or DVD material for system
upgrades. Item (a) in
Memory
16 GB.
Network
interfaces
Four on-board gigabit 10/100/1000 TX Ethernet copper ports
with RJ45 connectors. Item (e).
Two 10GbE optical ports provided with the Intel mezzanine
module. Item (g).
One dedicated management port. Item (f).
All items in Figure 4.
24
24
EMC® Cloud Tiering Appliance Getting Started Guide
Component
CTA8-HA-APL
VGA
Standard VGA video connector for a system console. Item (a) in
Figure 4.
Keyboard
connector
Standard USB keyboard connector for a system console. Item
(d) in Figure 4
Mouse
connector
Standard USB mouse connector for a system console. Item (c)
in Figure 4.
Models CTA8-APL and CTA8-HA-APL support four on-board gigabit Ethernet copper
10/100/1000TX ports, two 10 gigabit Ethernet SR (short range) optical ports, and one
dedicated management port (MGMT). Network console management for Gen 8
models describes how to use the management port.
Contents of the appliance
The CTA or CTA-HA ships with robust, fault-tolerant hardware consistent with the
mission-critical application for which it is used.
The following items are included in the appliance package:
•
Cloud Tiering Appliance (1U 19-inch rack-mountable Gen 8 model).
•
Two universal rails for mounting the appliance on a 19-inch rack.
•
Two sets of power cords.
•
Copper patch cables for the number of ports on your appliance.
•
Media kit with the software recovery DVD.
•
One crossover cable for Gen 8 models.
Note
The VGA monitor, keyboard, and mouse for a system console are not
included.
Appliance diagrams
These diagrams illustrate configurations of the CTA and CTA-HA.
Figure 4.
Rear view of Gen 8 appliance
EMC® Cloud Tiering Appliance Getting Started Guide
25
25
Figure 5.
Front view of Gen 8 appliance with bezel removed
Port details
Models CTA8-APL and CTA8-HA-APL support four on-board gigabit Ethernet copper
10/100/1000TX ports, two 10 gigabit Ethernet SR (short range) optical ports, and one
dedicated management port (MGMT). Network console management for Gen 8
models describes how to use the management port.
26
26
EMC® Cloud Tiering Appliance Getting Started Guide
Chapter 3
Installing the Cloud Tiering Appliance
This chapter contains the following sections:
Appliance setup ........................................................................................ 28
Installing the virtual edition ....................................................................... 28
CTA and CTA/VE for high availability ........................................................... 29
Network console management for Gen 8 models ........................................ 31
Performing a CD clean install on the appliance ........................................... 32
Performing a CD clean install on a generic server ........................................ 33
Adding the CTA serial number .................................................................... 34
Configuring CTA ......................................................................................... 34
File Encryption ........................................................................................... 37
Graphical user interface ............................................................................. 38
Command line interface ............................................................................. 39
EMC® Cloud Tiering Appliance Getting Started Guide
27
27
Appliance setup
Before an appliance may be used to perform tasks, the appliance and the software
must be properly configured:
•
If a Cloud Tiering Appliance (CTA) is being deployed, port details that are used
to connect the appliance to the network are provided in Chapter 2, Cloud
Tiering Appliance Hardware and Port Configurations.
•
If a Cloud Tiering Appliance/VE (CTA/VE) is being deployed, follow the
instructions in Installing the virtual edition.
•
If a Cloud Tiering Appliance for High Availability (CTA-HA) or Cloud Tiering
Appliance/VE for High Availability (CTA/VE-HA) is being deployed, CTA and
CTA/VE for high availability describes configuration considerations.
•
Follow the instructions in Network console management for Gen 8 models.
•
The CTA software is preinstalled on every new appliance. If the software must
be reinstalled and no previous CTA information or data needs to be retained,
follow the instructions provided in Performing a CD clean install on the
appliance.
•
To install the appliance on the network, follow instructions provided in
Configuring CTA.
•
If a CTA-HA or CTA/VE-HA is deployed and encryption is to be used, follow the
instructions provided in File Encryption.
•
If the system requires security hardening or any other special configuration,
Chapter 6, Cloud Tiering Appliance System Settings provides information for
all system settings.
Then proceed to configure the appliance for your environment as described in
Chapter 4, Deploying the Cloud Tiering Appliance.
Installing the virtual edition
The CTA/VE and CTA/VE HA are installed on the VMware server. Table 5 shows the
interoperability.
Table 5.
VMware ESX Server interoperability
Virtual
Appliance
VMware ESX
Server
CTA/VE
ESXi 5.0
ESXi 5.1
Comments
Four virtual CPUs, 16 GB of RAM, 1 TB of disk
space, 2 gigabit virtual interfaces are reserved.
ESXi 5.5
ESXi 6.0
CTA/VE HA
ESXi 5.0
ESXi 5.1
Four virtual CPUs, 4 GB of RAM, 100 GB of disk
space, 2 gigabit virtual interfaces are reserved.
ESXi 5.5
ESXi 6.0
28
28
EMC® Cloud Tiering Appliance Getting Started Guide
Note
If VMware snapshots will be used, reserve extra disk space when creating the
VMware datastore during installation. To estimate the total amount of disk
space to reserve for the datastore, add thirty percent of the size of the CTA/VE
VMDK file for each snapshot.
The following example shows the steps to install the CTA/VE or CTA/VE HA virtual
appliance using vSphere Client 5.0:
Download the CTA .OVA file.

For a CTA/VE, the file is: ctave-<version>.ova

For a CTA/VE HA, the file is: ctaveha-<version>.ova
Open the vSphere Client.
a.
Click the Hosts tab. To find the appliance with the most free space,
consider %CPU and %Memory.
b.
Select the line with the ESX server for the installation. A summary of the
CPU, memory, and data store capacities appears.
If the ESX Server has enough CPU and memory available to install the CTA/VE,
per the requirements of Table 5, proceed to the next step.
Import the OVA file. Instructions differ depending upon VMware version.
Select File > Deploy OVF Template.
On the Deploy OVF Template screen, click Browse to locate the OVA file.
Click Next through several screens until the Storage screen appears. Select the
destination storage on the appliance.
Click Next through several screens until the Ready to Complete screen appears.
Validate the information and click Finish.
The import may take 3–30 minutes depending on the network connection
between the VI Client and the VMware ESX Server. Approximately 1 GB will
initially be transferred across the network.
CTA and CTA/VE for high availability
High availability is a feature on both CTA and CTA/VE. Both the CTA-HA and the
CTA/VE-HA deliver solutions for a redundancy, which ensure that clients do not
experience data unavailability due to failure of the primary appliance.
When using CTA-HA or CTA/VE-HA for recall, callback services are configured on the
appliance or the virtual appliance.
•
CCD is used to recall files from Centera to VNX.
•
ACD is used to recall files from the cloud to VNX and Unity.
•
FPolicy callback is used to recall from all secondary devices to NetApp.
No callback is used for any of the NAS repository types, such as VNX, VNXe, Unity,
Windows, Isilon, NetApp, or Data Domain when the source is VNX.
EMC® Cloud Tiering Appliance Getting Started Guide
29
29
This configuration eliminates a single point of failure for the primary callback service
and ensures transparent client access to archived data.
To fulfill requirements for high availability, recall operations can be handled by a
group of appliances such as CTAs, CTA-HAs, CTA/VEs, or CTA/VE-HAs.
High availability with VNX or Unity primary storage
For VNX primary storage archived to a Centera, Atmos, or VNX, or Unity files archived
to Amazon S3 servers, ECS/S3, Azure, or Virtustream, the Data Movers/NAS servers
resolve an HTTP fully qualified domain name (FQDN) to the IP addresses of the
appliances. If a Data Mover/NAS server identifies multiple IP addresses mapped to
the same FQDN, it will select the first address it finds and attempt to send the recall
request. If the IP address is not responsive, the Data Mover/NAS server will select
subsequent addresses for the FQDN and attempt to send the recall requests to those
addresses.
All recall requests generated by a Data Mover/NAS server when resolving the FQDN
are sent to a single appliance even if multiple IP addresses are found. Each Data
Mover/NAS server can be configured to send recall requests to a preferred appliance
which provides coarse-grained load balancing of recall requests at the Data
Mover/NAS server level. For more information, see Deploying CTA with Unity.
To ensure that the Data Mover/NAS server will contact CTAs and CTA-HAs for recall,
first create a DNS record for the CTA, then add the IP addresses of all CTA-HAs to that
record. The same name points to the IP addresses of the CTA and all HA recall
devices. Configure name resolution for archiving provides details on how to use local
hostname resolution or DNS to add the HA appliances.
Run ccdsetup on all CTA-HAs or CTA/VE-HAs that will process recall requests from the
VNX Data Movers. Run acdsetup on all CTA-HAs or CTA/VE-HAs that will process recall
requests from the VNX Data Movers or Unity NAS servers. These scripts link multiple
appliances to process recall requests from a common set of VNX or Unity Data
Movers/NAS servers. Configuring VNX to Centera or cloud archiving on the CTA
provides details on ccdsetup and acdsetup.
No additional appliances are involved in recall when the CTA or CTA/VE archives data
from VNX primary storage to NAS repositories serving as secondary storage. The Data
Movers use the CIFS and NFS protocols to recall data directly from secondary storage.
High availability with NetApp primary storage
NetApp filers allow FPolicy clients (such as CTA, CTA-HA, CTA/VE, or CTA/VE-HA) to
register for callbacks in response to user access to files with specific attributes. When
using the appliances, a callback will be generated when a read/write operation
occurs to a file with the CIFS offline bit set.
For NetApp primary storage, multiple appliances can register in the primary or
secondary FPolicy groups of the filer. In the event that a registered server becomes
unresponsive, it is removed from its group. Recall requests will be sent by the filer in
a round-robin fashion to the IP addresses registered in the primary group. If there are
no responsive IP addresses in the primary group, then the requests are load-balanced
across the servers in the secondary group.
30
30
EMC® Cloud Tiering Appliance Getting Started Guide
Run fpsetup on the CTA-HAs or CTA/VE-HAs that will process recall requests. Use this
script to link together multiple appliances that will process recall requests that are
sent from a common set of NetApp Filers. Later, when configuring NetApp filers, you
will have the option to select specific appliances that will register in the primary and
secondary groups. Configuring NetApp archiving on the CTA provides details on
fpsetup.
Appliances are always involved in recall when the CTA or CTA/VE archives data from
NetApp primary storage to any secondary storage location. NetApp filers do not recall
data directly from VNX, Unity, Centera, or NetApp storage.
Note
If file encryption is not in use, a single CTA-HA or CTA/VE-HA can provide
redundancy for multiple CTAs or CTA/VEs. A single CTA or CTA/VE can have
multiple CTA-HAs or CTA/VE-HAs registered to provide redundancy. Do not use
a CTA to provide redundancy for another CTA or a CTA/VE to provide
redundancy for another CTA/VE.
Network console management for Gen 8 models
In the event that CTA or CTA-HA becomes unresponsive, network console
management allows users to control the appliance or reboot the system. For Gen 8
models based on Intel C1U hardware, communication is established through the
dedicated management port on the back of the appliance which is labeled MGMT in
Error! Reference source not found..
Note
For security purposes, network console management should be enabled on a
network with access limited to system administrators only.
Use the local console to configure the CTA for network console management and to
change the BMC Web Console Management User password.
Connect the power cord and power on the appliance.
Using a crossover cable, connect one end to your laptop Ethernet port and the
other end to the management port on the back of the appliance. The laptop must
be running Java Run Time Environment (JRE) version 6.0 update 10 or later.
Configure the laptop with static IP 192.168.1.2 and netmask 255.255.255.0.
In a web browser with the popup blocker disabled, type the IP address:
192.168.1.1. The CTA BMC Web Console appears.
To login to the console, type the username and password:
−
Username: root
−
Password: rain
The integrated BMC Web Console appears
To configure remote console management:
Select the Configuration tab.
Select IPv4 Network.
a.
For LAN Channel, select Intel(R) RMM.
EMC® Cloud Tiering Appliance Getting Started Guide
31
31
Note
b.
Change the IP address to a valid network IP address.
c.
Click Save.
Once remote console management is configured for the network IP address,
local console management is no longer available.
To change the BMC Web Console Management User password:
Select the Configuration tab.
Select Users.
a.
Under User Name, select root.
b.
Click Modify User. The Modify User page appears.
Type and confirm a password for the root user.
Using CTA CLI commands
To control the appliance from the console:
Type the network IP address of the BMC Web Console.
Login with the root user and password.
Select the Remote Control tab.
Select Console Redirection and click Launch Console.
A window appears with a message asking to open jviewer.jnlp. Click OK. A Java
applet window appears.
Type the CTA username and password to log in.
Command line interface provides information on the CTA CLI.
Rebooting the system
To reboot the appliance from the console:
Type the network IP address of the BMC Web Console.
Login with the root user and password.
Select the Remote Control tab.
Select Server Power Control.
Select Power Cycle Server and click Perform Action.
Performing a CD clean install on the appliance
CTA and CTA-HA are shipped with the software installed on the appliance. If needed,
a CD clean install installs all necessary packages and binary files. To perform a clean
install of CTA/VE or CTA/VE-HA see Installing the virtual edition.
Before starting the installation, check to see if the CTA is connected to another
appliance for HA, another CTA, or a stand-alone appliance with a callback daemon
running. If so, stop all callback daemons with the following commands:
fpolicycallback stop
32
32
EMC® Cloud Tiering Appliance Getting Started Guide
atmoscallback stop
celerracallback stop
To perform a CD clean install on a CTA or CTA-HA:
If using a downloaded ISO image:
a.
Run md5sum to verify the image integrity.
The output of the md5sum commands is in the README file that is
posted to Online Support, with all the downloads. Where to Get Help
provides information on how to access Online Support.
The ISO files are named:
cta-11.0.0-xxx.x86_64.iso
ctaha-11.0.0-xxx.x86_64.iso
b.
Burn a CD from the ISO image.
Insert the disk for CTA or CTA/HA depending on the CTA appliance type.
Boot CTA Appliance from the inserted disk.
When the appliance boots, choose Install/Restore_cta.
Choose Yes when the Destroying ALL data on /dev/sda, continue prompt
appears.
The appropriate packages are installed.
A restart occurs after installation completes and the login prompt appears.
Log in with username root and password rain.
Use the Cloud Tiering Appliance setup tool menu that appears to configure the
time and network settings.
If the CTA will be configured for VNX to cloud archiving, use FileMover Settings as
described in step 7 of Adding VNX to the CTA configuration.
Configure the single set of credentials for recall before running ccdsetup.sh or
acdsetup.sh as described in Configuring VNX to Centera or cloud archiving on the
CTA.
Performing a CD clean install on a generic server
When performing a bare metal installation of CTA/CTA-HA using the CD clean install
process, we recommend using the Dell Power Edge R630 configurations as the baseline
for hardware requirements. For configuration information, see Cloud Tiering Appliance
12 qualified hardware.
To perform a CD clean install of CTA or CTA-HA:
If using a downloaded ISO image:
a.
Run md5sum to verify the image integrity.
The output of the md5sum commands shown in the README file that is
posted to Online Support with all the downloads. Where to get help
provides information on how to access Online Support.
EMC® Cloud Tiering Appliance Getting Started Guide
33
33
The ISO files are named:
cta-11.0.0-xxx.x86_64.iso
ctaha-11.0.0-xxx.x86_64.iso
b.
Burn a DVD from the ISO image.
Insert disc for CTA or CTA/HA depending on the server you are installing.
Boot the server from the inserted disc.
When the server boots, choose Install/Restore_cta.
Choose Yes, when the Destroying ALL data on /dev/sda, continue prompt
appears.
The appropriate packages are installed.
A restart occurs after installation completes and the login prompt appears.
Log in with username root and password rain.
Use the Cloud Tiering Appliance setup tool menu that appears to configure the
time and network settings.
If the CTA will be configured for VNX to Centera or cloud archiving, use FileMover
Settings as described in step 7 of Adding a VNX to the CTA configuration.
Configure the single set of credentials for recall before running ccdsetup.sh or
acdsetup.sh as described in Configuring VNX to Centera or cloud archiving on the
CTA.
Adding the CTA serial number
Load the CTA serial number on the appliance with the CLI command:
rffm setEmcSerialNumber <EMCSERIALNUMBER>
where EMCSERIALNUMBER is located on a pull out card on the front of the appliance
or printed on the media kit label for CTA/VE versions of the product.
For CTA 12.0 systems, which are bundled with Unity, use the Unity serial number. To
obtain the Unity serial number, ssh to the management IP as service and run the
svc_diag command.
Example output of the svc_diag command:
======== Now executing basic state ========
* **System Serial Number is: VIRT162479MMTZ**
* System Friendly Host Name is: VIRT162479MMTZ-spa
* Current Software version: upc_Unity_4_4_upcBuilder4.1.0.8714268-GNOSIS_DEBUG
* UUID: 42377CA0-6DAF-8E3D-4519-BEAE20EDA933
* Unisphere IP address(es): X.X.X.X fe80::260:16fb:291c:32a7
Configuring CTA
Before proceeding with the setup, ensure that you have the following information for
each appliance:
34
34
EMC® Cloud Tiering Appliance Getting Started Guide
•
IP address
•
Subnet mask
•
Hostname
•
Default gateway IP
•
DNS server IP — If specifying multiple IP addresses, use spaces to separate IP
addresses.
•
CTA serial number from CTA packaging
Set up the appliance:
a.
For a CTA or CTA-HA, connect the keyboard and monitor to the appliance.
Connect the power cord and power on the appliance. If a keyboard and
monitor are not available, connect a PC or laptop using a crossover cable
connected to the MGMT port for Gen 8 models.
b.
For a CTA/VE, power on the appliance.
Log in to the appliance by using the local keyboard and monitor. Type root as the
login name. Type rain as the password.
The Cloud Tiering Appliance setup tool appears. This tool performs basic setup
tasks that are not available through the CTA GUI.
Select Change Cloud Tiering Appliance Password, and change the password.
Select Configure Cloud Tiering Appliance Networking. The network configuration
menu appears.
Use the menu to:
a.
Configure the CTA network.
b.
Configure the hostname, domain, and DNS server.
Select Configure date and time (including timezone). The current date/time and a
list of current NTP servers are displayed.
Use the menu to set the time zone and date for the appliance and configure an
NTP server.
Note
When archiving to the cloud (for example, Atmos, Amazon S3, or Azure), the
CTA clock must be accurate and in sync with the cloud service. Therefore it is
required to have an NTP server configured when archiving to these
destinations.
Configure the CTA network
Configure the CTA network:
Select option 1 from the Network Configuration menu. The Cloud Tiering
Appliance Network Setup, Main Menu appears.
On the list of available physical interfaces on the appliance, eth0 appears
highlighted. To highlight a different interface, use the up arrow and down arrow
keys.
With eth0 highlighted, press Enter. The configuration menu for the eth0 interface
appears:
EMC® Cloud Tiering Appliance Getting Started Guide
35
35
a.
Use the up arrow and down arrow keys to highlight the IP address field.
Press Enter and type a new IP address value into the New Value column.
Press Enter.
b.
Repeat the process to provide the subnet mask, gateway, and MTU
settings.
When the configuration for this interface is complete, press the left arrow key to
exit the eth0 interface configuration.
To save the interface configuration, select Yes and press Enter. Note that the
changes are saved, but will not be implemented until the Cloud Tiering Appliance
Network Setup menu is exited.
Press the left arrow key to exit from the Cloud Tiering Appliance Network Setup,
Main Menu. When prompted, select Yes to save your changes.
Configure the hostname, domain, and DNS server
Configure the hostname, domain, and DNS servers:
Select option 2 from the Network Configuration Menu. The following menu
appears:
EMC Cloud Tiering Appliance Setup Tool (Configure Hostname,
Domain and DNS Server(s))
Hostname
= fm
Domain
=
DNS Server
=
Do you want to change the configuration [Y/N]?
Type Y. Use the menu to configure the hostname, domain, and DNS servers.
The new hostname, domain, and DNS server information is summarized after all
the changes are entered, and you are given the ability to accept or make further
changes to these settings. To keep the new settings and return to the network
configuration menu, press Enter.
Verify that the network configuration has been saved and network connectivity
can be established properly.
Configure iSCSI IQN targets (Unity block archiving and restore only)
To use the block archiving and block restore features, the CTA need to have ISCSI IQN
targets configured.
Select option 3 from the Cloud Tiering Appliance setup tool.
Select option 3 from the Network Configuration Menu. The following output
appears:
EMC Cloud Tiering Appliance Setup Tool (Configure ISCSI IQN(s)
for block)
Auto generating ISCSI IQN for the first time ... iqn.199204.com.emc:cta:fm-0
36
36
EMC® Cloud Tiering Appliance Getting Started Guide
Update the hosts file
If /etc/hosts on the CTA requires customization, do not manually edit the file directly.
To customize the /etc/hosts file:
Edit the /etc/hosts.local file.
Select option 4 from the Network Configuration Menu to import changes from
/etc/hosts.local into /etc/hosts.
Note
If /etc/hosts is customized, maintain /etc/hosts.local to preserve those
customizations and restore /etc/hosts if needed.
File Encryption
Archiving to cloud services such as Atmos or Amazon S3 is a means of archiving at
rest data. However, there is a risk of compromising sensitive data stored in the cloud
unless file encryption is used.
To archive to the cloud with file encryption, a primary CTA or CTA/VE must be
deployed with a CTA-HA or CTA/VE-HA. The HA appliance is configured with a keystore
that replicates the keystore on the primary appliance. As long as a key is active and
the keystores on the HA and primary appliances are in sync, policy-based file level
encryption is enabled.
Note
If file encryption is active, a single CTA-HA or CTA/VE-HA cannot provide
redundancy for multiple CTAs or CTA/VEs.
Enabling keystore replication
The CTA supports encryption of data that is archived to a cloud platform, such as
Atmos or Amazon S3. To enable encryption on the CTA, you must enable replication of
the encryption keystore on the CTA-HA or CTA/VE-HA. The primary keystore is located
on the CTA, and the replica is created on the HA. Before enabling encryption, ensure
that NTP is configured on the CTA or CTA/VE and on the HA appliance.
To enable keystore replication on the CTA-HA or CTA/VE-HA, type:
krdsetup init_rffm
This stores the IP address of the main CTA or CTA/VE and the timestamp of the most
recently replicated keystore in the configuration file:
/opt/rainfinity/filemanagement/conf/krd.xml
Then it starts the keystore replication daemon that automatically keeps the keystore
on the high availability appliance in sync with the primary appliance.
Configuring and using file encryption
Once keystore replication has been enabled, the file encryption key can be generated
using the GUI on the primary appliance by selecting Configuration > File Encryption
Key.
EMC® Cloud Tiering Appliance Getting Started Guide
37
37
To archive to a cloud service with file encryption on, click Encrypted when adding a
rule to an archive policy. If no key is active, Encryption is grayed out.
To migrate secondary storage tier data to a cloud service with file encryption on, click
Encryption when selecting the destination for the repository migration task.
If an active key has not been replicated to the CTA-HA or CTA/VE-HA, an error appears
indicating that file encryption is not enabled.
Note
If a system administrator changes the CTA hostname or configures a network
interface, attempts to generate an encryption key on the CTA or synchronize a
keystore on the CTA-HA might fail. To work around this problem, reboot the
CTA.
Graphical user interface
To access the graphical user interface from a web browser:
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
The selections appear as follows:
38
38
c.
Dashboard — Top level view displays summaries of Common Tasks,
Alerts, and Reports.
d.
Schedule — Displays a list of scheduled tasks that are currently being
processed and the status of each task.
e.
Archives — Displays lists of archived files, LUNs, and consistency groups,
as well as an archived file report. Also provides a search option to find
archived files, recover stub files, and delete orphan files.
f.
Policies — Provides options that apply to creating and managing policies,
including:
−
A list of policies, matching expressions, and NAS destinations.
−
Create new policy.
−
Create new matching expression.
−
Create new NAS destination.
g.
Configuration — Provides configuration of servers, repositories, and
settings for servers.
h.
System — Provides system configuration of users, passwords, logs,
alerts, and security.
EMC® Cloud Tiering Appliance Getting Started Guide
Command line interface
As an alternative to the GUI, you can use a command line interface to send
commands to the filemanagement daemon.
To log in to the CLI by using SSH, the default username and password are:
•
Username: root
•
Password: rain
The most commonly used commands are:
•
fmsupportdump — Creates a dump of the appliance's current state for
technical support. Run this command from /var.
•
rffm — Configures the appliance and issues all commands that the GUI
interface supports. To see a list of all commands available, type rffm --help or
to view the man page for more detailed help, type man rffm.
•
fmbackup/fmrestore — Backs up and restores the configuration as described
in Backing up the configuration.
•
rssystat — Displays statistics about the CTA.
Man pages for the command line tools are stored in the software installation
directory. To access the man pages, type man command_name, as in man rssystat.
EMC® Cloud Tiering Appliance Getting Started Guide
39
39
Chapter 4
Deploying the Cloud Tiering Appliance
This chapter contains the following sections:
Deployment process for archiving .............................................................. 42
Supported platforms .................................................................................. 44
Deploying CTA with VNX ............................................................................. 45
Deploying CTA with NetApp ........................................................................ 57
Deploying CTA with a VNXe ........................................................................ 64
Deploying CTA with Unity ........................................................................... 65
Deploying CTA with Virtustream.................................................................. 70
Deploying CTA with a Windows server......................................................... 71
Deploying CTA with Isilon ........................................................................... 74
Deploying the CTA with Data Domain .......................................................... 80
Configuring a NAS-based repository ........................................................... 81
Deploying CTA with Amazon S3 .................................................................. 82
Deploying CTA with Atmos.......................................................................... 83
Deploying CTA with Azure........................................................................... 85
Deploying CTA with Centera ....................................................................... 86
EMC® Cloud Tiering Appliance Getting Started Guide
41
41
Deployment process for archiving
Figure 6 illustrates how the Cloud Tiering Appliance (CTA) or Cloud Tiering
Appliance/VE is deployed for archiving.
Note
Figure 6.
42
42
The first time you install and configure the CTA system, click the Add Task
Wizard in the CTA dashboard to guide you through the steps of configuring
your system, archiving, or migration task.
Cloud Tiering Appliance deployment process
EMC® Cloud Tiering Appliance Getting Started Guide
Note
For VNX to NAS configuration, NAS repositories can be VNX, VNXe, Windows,
Isilon, NetApp, or Data Domain.
For details on deploying the CTA or CTA/VE in various environments, see the following
sections. Steps in the five boxes at the bottom of the flowchart are performed by
using the CTA GUI. The online help describes these steps in detail.
Step 1: Set up CTA
Install the CTA/VE, if applicable.
Add the CTA serial number.
Configure CTA networking.
Enable the keystore on the HA for file encryption to the cloud, if applicable.
Step 2: Configure the archive environment
Unity to the Cloud
Configure Unity properties.
Initialize recall services.
Configure name resolution for recall.
Configure Unity settings under Common API Settings.
Configure DHSM.
VNX to Centera or the Cloud
Configure VNX properties.
Initialize recall services.
Configure name resolution for recall.
Configure VNX settings under Common API Settings.
VNX to NAS
Configure VNX properties.
Configure VNX settings under Common API Settings.
Configure DHSM.
NetApp
Configure ONTAPI.
Configure vFilers, if applicable.
Initialize recall services.
Configure NetApp properties.
Step 3: Configure the destination
Configure NAS repositories.
Configure non-NAS repositories.
EMC® Cloud Tiering Appliance Getting Started Guide
43
43
Step 4: Define policies
Create matching expressions and archive destinations.
Specify policy type, retention, delayed stubbing, stub retention (as applicable).
Step 5: Create a task
Create an archive, delete, or auxiliary task.
Select the source, as applicable.
Step 6: Run the simulation task (optional)
Select Run Simulation Now.
Collect real-time results in CTA.
Review policy efficacy against real-time results.
Step 7: Run the policy task
Determine optimal task scheduling.
Select archive conditions or start times (as applicable).
Monitor archiving activity for errors.
Supported platforms
Platform support varies depending on the task performed.
Table 6 shows platform support for archiving.
Table 6.
Supported platform matrix for archiving
Primary tier
Secondary tier
VNX
VNX
NetApp
VNXe
Unity
Windows
Isilon
NetApp
Data Domain
Centera
Atmos
Amazon S3
Microsoft Azure
Unity
Amazon S3
ECS/S3
Microsoft Azure
Virtustream
44
44
EMC® Cloud Tiering Appliance Getting Started Guide
VNX, VNXe, Unity, Windows, Isilon, NetApp, and Data Domain are collectively referred
to as NAS repositories, as described in Configuring a NAS-based repository.
Table 7 shows platform support for file migration.
Table 7.
Supported platform matrix for file migration
Source
Destination
VNX
VNX
VNXe
Isilon
NetApp
VNX
VNXe
Isilon
Windows
VNX
VNXe
Note
Stub retention for Windows is not supported. The destination must be offline
until migration is complete. Otherwise there is a risk of data loss or damage.
CTA does not support server message block (SMB) signing. For CTA to authenticate
properly with a CIFS file server, SMB signing must be disabled within the Active
Directory domain. If SMB signing is required and enabled for client-server
communications, CTA cannot browse CIFS shares on the file server or execute any
CIFS archiving tasks.
Deploying CTA with VNX
To use CTA with a VNX Data Mover, first perform configuration steps on the CTA, and
then on the VNX Control Station.
VNX supports DART version 7.0 or later.
With VNX as a source, the deployment requirements vary with task type.
Table 8.
VNX deployment checklist
Configure:
File Migratiion
Archiving
System prerequisites

VNX properties
including NDMP
NDMP not required
Callback daemon: CCD,
ACD
N/A

Name resolution
N/A

VNX Control Station



EMC® Cloud Tiering Appliance Getting Started Guide
45
45
Configure:
File Migratiion
Archiving
DHSM


Prerequisites for using VNX as a file migration source or destination
To migrate files to or from a VNX Data Mover, ensure that the following conditions are
satisfied:
•
CTA requires access through both CIFS and NFS to complete a file migration
(KB Article Number 000464016).
•
For NFS, CTA has root access with read/write permission on source and
destination exports.
•
CIFS user has local administrator access on all source and destination shares
and is part of the Backup Operators group.
•
If migrating files from a source that is shared and exported, CTA has root
access with read/write permission to both shares and exports.
•
If migrating dedupe files from VNX to Isilon, set the backup data threshold for
VNX File Deduplication and Compression on a Data Mover to 0 before
migration:
$fs_dedupe -default -set <movername> -backup_data_threshold 0
Where movername is the name of the Data Mover.
After migration, set fs_dedupe back to its original value.
Note
Do not run any other backup applications on the Data Mover while migration
is running because this is a global parameter that will cause all other backup
applications to inflate dedup files.
•
Snapsure snapshots are enabled on the source.
•
There is a system user for the XML API setup on the VNX Control Station.
Configuring automatically created DHSM connections for file migration or
archiving describes how to set up the user.
The system user for the XML API is not needed for VNX as a destination.
•
For every server, properties are configured on the CTA for:
−
Control Station IP address for VNX as source
−
NDMP username and password
Adding VNX to the CTA configuration provides details on configuring a VNX server.
Prerequisites for VNX as an archive source
To archive data from a VNX Data Mover, the CTA requires access to the Common API
(TCP port 5080).
To archive NFS data, the CTA needs the following:
•
46
46
Mount v3 RPC service
EMC® Cloud Tiering Appliance Getting Started Guide
•
NFS v3 RPC service
•
NLM v4 RPC service
•
Root access with read/write export permissions for all NFS data that will be
archived.
To archive CIFS data, the CTA needs SMB over NetBIOS (TCP port 139).
Direct command line access to the VNX Control Station is not used by the CTA.
When configuring VNX Data Mover properties on the CTA, plan to provide:
•
Credentials for a Common API user. This single set of credentials is used for
both archive and recall.
•
Control Station IP address.
•
(For CIFS archiving only) The NetBIOS name of the file server or Kerberos
FQDN.
•
(For CIFS archiving only) Credentials for Windows domain user.
When archiving to a NAS repository, virus scanning can have the following effects:
•
Virus scanning on the destination will negatively impact CTA performance and
should be disabled.
•
Virus scanning on the destination can also delete files, leaving stub files on
primary storage that cannot be opened.
•
Virus scanning can be enabled on the source, but scanning on read can cause
time out conditions with no reply errors on the source if CTA is the first
application to access a file.
To disable virus scanning on the VNX, mount the file system with the noscan option.
Adding VNX to the CTA configuration
Note
The VNX Properties page is not displayed.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a. Username: admin
b. Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select VNX. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
EMC® Cloud Tiering Appliance Getting Started Guide
47
47
Step
Description
Type the NetBIOS server name.
To identify the VNX fileserver as a VDM
(Virtual Data Mover), select the File Server Is
VDM checkbox. Then do one of the following:
Basic File Server
Information
• When the File Server Is VDM checkbox is
enabled, ensure that the NFS exports are
created on the physical Data Mover and
not on the VDM. In this scenario, the
interface used by the VDM should not be
attached to the VDM.
• When the File Server Is VDM checkbox is
disabled, ensure that the NFS exports are
created on the VDM and not on the
physical Data Mover. In this scenario the
interface used by the VDM should be
attached to the VDM.
Type the Data Mover IP address:
When editing an existing server, click Update
to retrieve the IP address from the DNS that is
based on the server name.
To specify an additional IP address, click Add.
To delete an existing IP address, select an IP
and click Delete.
IP Addresses
The Control Station IP is required for file
migration transactions and is used to create a
snapshot of the source. For archiving, this
allows CTA to automatically perform some
prerequisite tasks for archiving as described
in Configuring automatically created DHSM
connections If this field is empty, the CTA
takes no action and the prerequisite tasks
must be performed manually.
This is the Windows domain user to be used
by the appliance. The domain user must be a
member of the local Administrator group and
part of the Backup Operators group on the
VNX system. Windows domain user provides
more information.
CIFS Specific Settings
48
48
EMC® Cloud Tiering Appliance Getting Started Guide
Specify either a NetBIOS domain or a
Kerberos FQDN. The Kerberos FQDN is a CTA
server configuration setting, and if selected,
the same FQDN applies to all servers. Before
selecting the Kerberos FQDN option, follow
steps in Configuring Windows for Kerberos to
configure your Fully Qualified Domain on the
CTA.
Step
Description
NDMP Specific Settings
For file migration, type the username and
password for an NDMP user on the source
and destination servers. By default, the port
for NDMP traffic is 10000.
Note
VNX system as Source
NDMP specific settings do not apply for
Windows to VNX migration.
This option configures the CTA to archive data
from the VNX Data Mover. If multiple
appliances are connected to the same VNX
Data Mover, only one appliance should be
configured with the VNX as Source. This
option is required only if the VNX is serving as
a source for archiving.
Multiple appliances may be configured to
archive data from a single VNX Data Mover,
but only one CTA or CTA/VE should be used to
archive data from a single filesystem.
The CCD DNS Name is required if archiving to
a Centera. For the CCD DNS name, type the
FQDN of the VNX Callback DNS entry. Note
that the FQDN is case-sensitive.
CCD DNS Name
ACD DNS Name
This step appears if VNX as
source is yes.
Directory Exclusion List
This step appears VNX as
source is yes.
The ACD DNS Name is required if archiving to
a cloud storage server. For the ACD DNS
name, type the FQDN of the Cloud Callback
DNS entry. Note that the FQDN is casesensitive.
The DNS names for the VNX Callback agent
and Cloud Callback agent must be distinct.
They cannot be the same. If a callback name
is not specified, archive tasks to the
destination will not start.
These are the directories to exclude for all
tasks that use scanning. Migration tasks do
not scan, so this setting does not apply to file
migration. The CTA ignores all system
directories such as, etc, lost+found, and ckpt
by default.
Verify that stub files are not in the excluded
directories. CTA will not access the excluded
directories and the stub files will become
orphans.
Review the Summary and click Finish to define the VNX file server.
Select Configuration and Common API Settings. The Common API Settings page
appears.
Type the username and password for the FileMover Credentials.. The system uses
this username and password to create an HTTP connection by using XML API. This
EMC® Cloud Tiering Appliance Getting Started Guide
49
49
same username and password are used when creating the FileMover user in
Prerequisite tasks on the VNX Control Station for file migration or archiving
The FileMover setting applies to all VNX file servers configured on the CTA. If all
VNX file servers are archive targets only, the FileMover setting is not required.
Note
Because CTA migrates data using NDMP, it can migrate both NFS and CIFS
metadata in a single protocol migration, provided that the NDMP format does
not require conversion. For example, when both the source and destination
are VNX systems, no conversion is necessary. However to migrate NFS and
CIFS metadata between systems that require NDMP format conversion, you
must both export and share the file system. For example, CTA cannot migrate
CIFS data in an NFS migration involving systems other than VNX. This is
because after CTA converts the NDMP data stream, it can only migrate CIFS
metadata using CIFS protocol.
Configure name resolution for archiving
When the VNX Data Mover needs to establish a connection to the appliance to recall
data from a Centera or a cloud service, it tries to resolve the FQDN from the HTTP
DHSM connection in its local hosts file. If it cannot be resolved locally, the Data
Mover will use DNS.
Note
•
These instructions pertain only to configuring the hosts file on the VNX.
Configuring CTA provides information on how to configure the CTA hosts file.
To use DNS:
a.
Create a DNS entry for the callback daemon that points to the appliance.
As a best practice, the CTA hostname and CCD hostname should be different.
Using the same hostname for both can raise issues when trying to login to the
appliance.
Note
•
b.
Create multiple entries by the same name for each callback appliance.
c.
For each entry that is created, select the checkbox for Create associated
pointer (PTR) record to ensure that it will be included in the Reverse
Lookup Zones list.
The VNX FileMover supports DNS HA failover. If the DNS server resolves the
callback daemon hostname to multiple IP addresses, the VNX FileMover
transparently switches to the server at the next available IP address.
DNS is the preferred method for name resolution. If using DNS is not feasible,
use local hostname resolution:
a.
Log in to the VNX Control Station as root and mount the Data
Mover to edit the local hosts file with vi:
mount server_2:/ /mnt/source
cd /mnt/source/.etc
vi hosts
where server_2 is the name of your VNX Data Mover.
b.
50
50
Edit the hosts file to add one line for each appliance, similar to the
following example:
EMC® Cloud Tiering Appliance Getting Started Guide
10.0.0.1
10.0.0.2
10.0.0.3
10.0.0.1
10.0.0.2
10.0.0.3
<rainccd.domain>
<rainccd.domain>
<rainccd.domain>
<rainacd.domain>
<rainacd.domain>
<rainacd.domain>
#
#
#
#
#
#
CCD
CCD
CCD
ACD
ACD
ACD
on
on
on
on
on
on
CTA-HA
CTA
CTA/VE
CTA-HA
CTA
CTA/VE
where:
−
rainccd.domain is the FQDN that will be used to create the HTTP DHSM
connection described in Adding VNX to the CTA configuration (see
description for CCD DNS Name).
−
rainacd.domain is the FQDN that will be used to create the HTTP
DHSM connection described in Adding VNX to the CTA configuration
(see description for ACD DNS Name).
c.
Save the file and confirm that the VNX Control Station is not mounted to
the Data Mover:
cd ~
umount /mnt/source
Configuring VNX to Centera or cloud archiving on the CTA
To archive from a VNX to a Centera or cloud storage, configure the callback service so
that the CTA is in the recall path.
Configure the callback service to recall from Centera
To configure recall from the Centera:
From the console on the CTA, log in as root.
Type ! to escape to the command line and type:
ccdsetup init_rffm
Type n when the following message appears:
By default the Celerra Callback Daemon will connect to the
CTA service on the local machine.
Do you wish to configure another CTA? (y/n)
If there is a secondary callback agent such as a CTA-HA, log in on that agent as
root, and repeat steps 2 and 3. In step 3, type y to provide the IP address and the
root password of the CTA.
If an invalid IP address is provided, the CCD.log file located in
/var/log/rainfinity/filemanagement/recall will fill with errors to indicate that there
was no response from the primary agent. To correct the problem, repeat steps 2
through 4 of this procedure.
Configure the callback service to recall from the cloud
To configure recall from the cloud service such as Atmos or Amazon S3:
From the console on the CTA, log in as root.
Type ! to escape to the command line and type:
acdsetup init_rffm
EMC® Cloud Tiering Appliance Getting Started Guide
51
51
Type n when the following message appears:
By default the Cloud Callback Daemon will connect to the CTA
service on the local machine.
Do you wish to configure another CTA? (y/n)
If there is a secondary callback agent such as a CTA-HA, log in on that agent as
root, and repeat steps 2 and 3. In step 3, type y to provide the IP address and root
password of the primary callback agent.
If an invalid IP address is provided, the ACD.log file located in
/var/log/rainfinity/filemanagement/recall will fill with errors to indicate that there
was no response from the primary agent. To correct the problem, repeat steps 2
through 4 of this procedure.
Prerequisite tasks on the VNX Control Station for file migration or archiving
If a VNX has not been configured as a source for file migration or archiving, perform
the following steps:
Enable filename translation on the VNX Control Station.
The CTA, CTA-HA, or CTA/VE expects that all filenames are derived from the VNX
Network Server in UTF-8 format. To preserve filenames correctly:
a.
Log in to the VNX Control Station as nasadmin.
b.
Use a text editor to open the file: /nas/site/locale/xlt.cfg.
c.
Locate the last line of the file. Typically the last line appears as:
::::8859-1.txt: Any thing that didn’t match above will
be assumed to be latin-1
Add the following line immediately above the last line:
::CTA_IP_ADDR::: CTA requires no translation (UTF-8)
where CTA_IP_ADDR is the IP address of your appliance. Add an entry for
each CTA. HA appliances are not added.
For example, if the IP address is 10.10.18.1, type:
::10.10.18.1::: CTA requires no translation (UTF-8)
To specify a subnet, type:
::10.10.18.0,255.255.255.0::: CTA requires no
translation (UTF-8)
d.
To update the configuration, type:
/nas/sbin/uc_config -update xlt.cfg
e.
To verify the new configuration, type:
/nas/sbin/uc_config -verify CTA_IP_ADDR -mover ALL
where CTA_IP_ADDR is the IP address of your appliance. Output will
appear in the format:
server_name : CTA_IP_ADDR is UTF-8
52
52
EMC® Cloud Tiering Appliance Getting Started Guide
Create the FileMover user. Log in to the VNX Control Station CLI as root and type
the command:
/nas/sbin/server_user <data_mover> -add -md5 -passwd <user>
For example: /nas/sbin/server_user server_2 -add -md5 -passwd rffm
The username and password must match the FileMover Credentials under
Common API settings configured on the CTA in Adding VNX to the CTA
configuration.
Allow the IP addresses of the CTA or CTA/VE to open connections to the FileMover
interface. While logged in to the VNX Control Station as an administrator (such as
“nasadmin”), run the following command for all IP addresses of all appliances
that will perform archiving or service recall requests for the Data Mover:
server_http <data_mover> -append dhsm -users <user> -hosts
<ip_address>
For example: server_http server_2 -append dhsm -users rffm -hosts
192.168.0.100,192.168.0.101, <CTA_IP_address>
Note
A single VNX Data Mover can be configured as an archiving source with
multiple appliances, but more than one CTA or CTA/VE should never be
used to archive data from a single filesystem.
Enable DHSM (FileMover) for the Data Mover. To enable DHSM and keep it
enabled if the Data Mover reboots, run the following command once:
server_http <data_mover> –service dhsm –start
Enable DHSM for specific filesystems that will be used as archiving sources. To
enable DHSM and keep it enabled if the Data Mover reboots, run the following
command once per filesystem.
fs_dhsm -modify <primary_fs> -state enabled
For example: fs_dhsm -modify fileSystem1 -state enabled
Ensure that the DHSM offline attribute is enabled for filesystems that will be used
for archiving. To verify that the offline attribute is on, run the command:
fs_dhsm -i <fs_name> | grep ’offline attr’
−
If the offline attribute is on, the following line will appear:
offline attr = on
−
If the offline attribute is off, turn it on with the command:
fs_dhsm -m <fs_name> -offline_attr on
Caution
Once the offline attribute is set to on, it must remain on.
Disabling the offline attributes after executing archive tasks can
lead to data loss.
Create one or more connections from the Data Mover to the secondary storage
locations for each filesystem that will be archived. Each CIFS or NFS repository used
to store archived data needs to be configured as a DHSM connection for the VNX
filesystem. If data will be archived to a Centera or cloud storage service, a DHSM
EMC® Cloud Tiering Appliance Getting Started Guide
53
53
connection that uses the HTTP protocol must be configured for that filesystem to the
CTA or callback FQDN.
Configuring automatically created DHSM connections for file migration or archiving
The CTA or CTA/VE can automatically create DHSM connections for VNX systems
running DART 7.0.
To configure this feature, perform the following steps as root user on the VNX and the
appliance:
Run the commands on the VNX as root user, and not as nasadmin.
Check to see if the XML API server is running on the VNX, type:
ps -ef | grep start_xml_api_server | grep -v grep
The following example shows a server that is already running:
[root@celerra01 sbin]# ps -ef | grep start_xml_api_server |
grep -v grep
root
14821 3226 0 15:41 ?
00:00:00 /bin/sh
/nas/sbin/start_xml_api_server

If it is running, restart the server by typing:
/nas/sbin/hup_api

If it is not running, start the server by typing:
/nas/sbin/start_xml_api_server
If the server fails to start or restart:
a.
Delete the file /nas/api/exit_now.
b.
Delete the file /nas/api/api_retry.
c.
Repeat the process to check if the server is running and to start it.
If the XML API server still fails to start, contact VNX support.
Create a new system user for the XML API. Use the API GUI on the VNX Control
Station.


For a new user on a VNX running DART 7.x:
a
Log into Unisphere as root. For Scope, select Global.
b
Select: Settings > Security > Local Users > Create. The New User screen
appears.
For a new user on a VNX running DART 7.1.x:
a
Log into Unisphere as sysadmin. For scope, select Global.
b
Select: Settings > Security > User Management > Local Users for File >
Create. The New User screen appears.
Use the same username and password that was defined for the Common API
user in Prerequisite tasks on the VNX Control Station for file migration or
archiving.
54
54
EMC® Cloud Tiering Appliance Getting Started Guide
When a user password is updated or changed on the VNX Control Station,
update the FileMover Credentials under Common API settings for the VNX
Properties on the appliance as in Adding VNX to the CTA configuration and
update the DHSM connection password with the command:
fs_dhsm -connection <primary_fs> -modify <cid> -password
<new_password>
Define VNX Data Mover properties on the CTA or CTA/VE. Adding VNX to the CTA
configuration describes the following properties in greater detail:
a.
For Control Station, provide the Control Station IPs.
b.
For FileMover Settings, type the username and password that were
created for the new system user.
If DHSM connections do not exist, the CTA automatically creates the connections
before running each archiving task.
Configuring manually created DHSM connections for file migration or archiving
DHSM connections must be created manually if any of the following conditions apply:
•
DART 6.0 is being used with an NFS-exported filesystem on a VDM.
•
The CTA is not being used to automatically create DHSM connections.
Commands to create the connection for different archiving scenarios are provided as
follows:
•
When archiving CIFS data to NAS, you archive to a CIFS repository configured
on the appliance.
Create a connection to each CIFS repository that will hold archived data. This
setting applies to any repository that is part of a multi-tier destination. Log in to
the CLI of the VNX Control Station and type the command:
fs_dhsm -connection <primary_fs> -create -type cifs –admin
‘<fqdn>\<domain_administrator>’ –secondary
‘\\<fqdn_of_secondary_server>\<repository_path>’ -local_server
<local_cifs_server>
For example: fs_dhsm -connection fileSystem1 -create -type cifs -admin
'mydomain.prv\administrator' -secondary '\\oldServer.mydomain.prv\dir1\dir2' local_server ns80dm1
Note
•
Use the apostrophe instead of quotation marks to encapsulate the
CIFS administrative username and UNC path of the secondary storage
location.
When archiving NFS data to NAS, you archive to an NFS repository configured
on the appliance.
Create a connection to each NFS repository that will hold archived data. Log in to
the CLI of the VNX Control Station, and type the command:
fs_dhsm -connection <primary_fs> -create -type nfsv3 –secondary
‘<fqdn_of_secondary_server>:/<repository_path>’ -proto TCP –
useRootCred True
EMC® Cloud Tiering Appliance Getting Started Guide
55
55
For example: fs_dhsm -connection fileSystem1 -create -type nfsv3 –secondary
‘oldServer.mydomain.prv:/dir1/dir2’ -proto TCP –useRootCred True
•
When archiving any type of data to an Centera CAS or cloud storage server,
recall requests will flow from the Data Mover to CTA, CTA-HA, or CTA/VE.
c.
To create the connection for an Centera, log in to the CLI of the VNX
Control Station, and type the command:
fs_dhsm -connection <primary_fs> -create -type http –
secondary 'http://<fqdn for CCD>/fmroot' -httpPort 8000 cgi n -user <user> -timeout 60
For example: fs_dhsm -connection fileSystem1 -create -type http –secondary
'http://CCD01.mydomain.prv/fmroot' -httpPort 8000 -cgi n -user rffm timeout 60
When prompted, type a password for the file mover settings username .
d.
To create the connection for a cloud storage server, log in to the CLI of the
VNX Control Station and type the command:
fs_dhsm -connection <primary_fs> -create -type http –
secondary 'http://<fqdn for ACD>/fmroot' -httpPort 9000 cgi n -user <user> -timeout 60
For example: fs_dhsm -connection fileSystem1 -create -type http –secondary
'http://ACD01.mydomain.prv/fmroot' -httpPort 9000 -cgi n -user rffm -timeout
60
When prompted, type a password for the ‘rffm’ user.
These same settings are used in Adding VNX to the CTA configuration.
e.
The FQDN for the callback daemon is used for CCD DNS Name and ACD
DNS Name. For more information, see Adding VNX to the CTA
configuration. The FQDN must be distinct even if the VNX and cloud
callback daemons are running on the same appliance.
f.
The same user and password credentials are used for FileMover
Credentials under Common API Settings in Adding VNX to the CTA
configuration.
Regardless of the type of connection (CIFS, NFS, or HTTP), the target of a connection
should be specified as a hostname or FQDN in the command:
fs_dhsm -connection <primary_fs> -create
56
56
•
When a VNX Data Mover needs to establish a connection to secondary
storage, it first attempts to resolve the hostname in the local hosts file. If the
name cannot be resolved locally, the Data Mover then issues a DNS query.
•
When archiving to NAS from a VNX, a DNS record is required to resolve the
FQDN of the secondary storage server to IP addresses if the local hostname
resolution of the VNX is not going to be used. A PTR record (reverse DNS) is
also required to map the IP addresses of the secondary storage server to the
FQDN.
Note
The VNX File Level Retention (FLR) enabled filesystems cannot be used as an
archiving source.
EMC® Cloud Tiering Appliance Getting Started Guide
Deploying CTA with NetApp
To use the CTA with a NetApp filer, first configure the filer, and then configure the
appliance.
With NetApp as a source, the deployment requirements vary with task type.
Table 9.
NetApp deployment checklist
Configure:
File Migratiion
Archiving
System prerequisites


NetApp properties
including NDMP
NDMP not required
NetApp vFiler prerequisites
if applicable + ndmpd
if applicable
Callback daemon: FCD
N/A

Prerequisites for using NetApp as a file migration source
To migrate files from a NetApp, ensure that the following conditions are satisfied:
•
For NFS, CTA has root access with read/write permission on source exports.
•
CIFS user has local administrator access on all source shares and exports.
•
If migrating files from a source that is shared and exported, CTA has root
access with read/write permission to both shares and exports.
•
Create unicode and convert unicode options on the volume are enabled from
the NetApp console with the vol options command.
•
NDMP is enabled from the NetApp console by typing:
ndmpd on
options ndmpd.authtype plaintext
•
For NetApp filers running Data ONTAP 7.2 or later, disable duplicate session
detection by typing:
options cifs.client.dup-detection off
Note
•
CTA works best with duplicate session detection disabled. However, if
the network environment requires duplicate session detection, the
option can be set to name.
NDMP specific settings are specified for every NetApp filer configured on the
CTA.
Adding NetApp filer to the CTA configuration provides details on configuring a
NetApp server.
Prerequisites for using NetApp as an archiving source
To archive any data from a NetApp filer, the CTA or CTA/VE requires access to:
•
SMB over NetBIOS (TCP port 139)
EMC® Cloud Tiering Appliance Getting Started Guide
57
57
•
ONTAPI (TCP port 80)
In addition, to archive NFS data, the CTA or CTA/VE will require the following:
•
Portmap v2 RPC service (TCP port 111)
•
Mount v3 RPC service
•
NFS v3 RPC service
•
NLM v4 RPC service
•
Root and read/write export permissions for all NFS data that will be archived
•
inode to pathname mapping is enabled for NFS clients that will access stub
files
When configuring a NetApp filer on the CTA or CTA/VE, plan to provide:
•
All IP addresses that are used by the filer
•
Credentials for local administrator access through both CIFS and ONTAPI
•
The NetBIOS name of the filer
Note
If a NetApp filer leverages its vScan interface for virus scanning, the IP
addresses of the vScan servers must be configured on the appliance as
excluded clients on the NetApp FPolicy Special Clients configuration page in
the GUI. This allows the virus scanner to scan the stub file upon a recall event.
Failure to configure excluded clients properly will lead to recall failures when
vScan is used in conjunction with FPolicy.
Local administrator’s credentials are required because ONTAPI access is used to send
API calls. If a user other than root is specified, the following option must be set:
options httpd.admin.hostsequiv.enable on
Ensure that the appliance hostname:
•
Can be resolved to its IP addresses in the local /etc/hosts file of the NetApp
filer.
•
Maps to a user with privileges to access the ONTAPI interface in the
/etc/hosts.equiv file on the filer.
Additional configuration prerequisites vary, depending upon the existing network
environment.
If using a vFiler, precede all options commands with vfiler run <vfiler_name>.
•
Set the following NetApp options by typing:
options
options
options
options
options
options
options
58
58
fpolicy.enable on
cifs.nfs_root_ignore_acl on
httpd.admin.hostsequiv.enable on
httpd.admin.enable on
nfs.tcp.enable on
nfs.udp.enable on
cifs.netbios_over_tcp.enable on
EMC® Cloud Tiering Appliance Getting Started Guide
•
If using NFS to archive CIFS shares, type:
options wafl.nt_admin_priv_map_to_root on
And add the following line in the /etc/usermap.cfg file:
<domain_name>\<cifs_user> == root
For example: domainABC\userABC == root
•
For NetApp filers running Data ONTAP 7.2 or later, disable duplicate session
detection by tping:
options cifs.client.dup-detection off
Note
•
CTA works best with duplicate session detection disabled. However, if the
network environment requires duplicate session detection, the option can
be set to name.
To properly support stub files, NetApp FPolicy requires a particular CIFS offline
bit attribute on the stub files:
g.
The CIFS protocol must be enabled on the NetApp filer to archive either
CIFS or NFS datasets. An active CIFS license must be installed on all file
servers that are archive sources.
h.
NFS-only exports must be shared as well.
•
To properly recall stub files, FPolicy must be enabled (options fpolicy.enable
on) and rfpolicy must be the only screen policy registered for reads and
writes. If a policy that monitors stub files on the NetApp filer was previously
installed, manually delete it.
•
To configure NFS archiving, perform the following steps on the NFS-only
source directories:
Note
•
i.
Create a share at the qtree or volume level for qtree sources.
j.
Create a share at the volume level for non-qtree sources, that is, those
not part of any qtree.
k.
Add access to only the CTA user.
The CTA does not support name clashes on qtrees. For example, QTREE1
against qtree1.
Configure the NetApp source for UTF-8 language encoding with the command:
vol lang <vol> <language_encoding>
where language_encoding ends with .UTF-8, for example en_US.UTF-8.
•
If a virus scanning or backup program runs on your NetApp filer, type the IP
address of the machines that host these applications as Excluded Clients on
the NetApp FPolicy Special Clients configuration GUI page.
•
When archiving to a NAS repository, virus scanning on the destination will
negatively impact CTA performance and should be disabled. Virus scanning
on the destination could also delete files, leaving stub files on primary
storage that cannot be opened. Virus scanning can be enabled on the source
EMC® Cloud Tiering Appliance Getting Started Guide
59
59
when needed, however scanning on read should not be enabled because it
can cause a timeout and no reply errors on the source during archiving.
vFiler configuration
To use NetApp vFilers with the CTA, ensure that:
•
The CTA can access both the vFiler and the hosting NetApp filer.
•
vFilers and main filers are in IP spaces that can reach each other.
If NetApp vFilers are being used for file migration, the root password is not the same
as the NDMP password. Before configuring NDMP for the vFiler on the CTA, use the
NetApp CLI to retrieve the NDMP password by typing:
ndmpd password root
Either use this password, or create a new NDMP username and password when
configuring NDMP in Adding NetApp filer to the CTA configuration.
Configuring NetApp archiving on the CTA
To archive from the NetApp filer, configure the FPolicy callback service on the CTA,
CTA-HA, or CTA/VE.
Type the following:
fpsetup init_rffm
At the prompt that appears, select the interface on which the FPolicy callback
daemon should listen for callbacks from NetApp filers. If there is only one
interface, it will be selected automatically:
a.
If this is the primary callback agent in the environment, type n.
b.
If this machine is being configured as the secondary callback agent, type
y. When prompted, type the IP address and the root password of the
primary agent.
Adding NetApp filer to the CTA configuration
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Server page that appears, select NetApp. Click OK.
60
60
EMC® Cloud Tiering Appliance Getting Started Guide
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the NetBIOS server name.
IP Addresses
Type the IP address for NetApp filer:
When editing an existing server, click Update to retrieve the IP
address from the DNS that is based on the server name.
To specify an additional IP address, click Add.
vFiler Host IP
Address
To delete an existing IP address, select an IP and click Delete.If using
a vFiler with
OnTAP versions earlier than 7.3, type the IP address of the hosting
NetApp filer.
CIFS Specific
Settings
This is the Windows domain user to be used by the appliance. To
avoid permission issues during archiving, recall, and migration, add
this user who is a domain user to the backup operator group. Log in
as root on the NetApp and type:
useradmin domainuser add <user> -g "Backup Operators"
where user is the Windows domain username for login.
If this user is not in the domain administrator group, add it to the file
server's local administrators group. Log in as root on the NetApp and
type:
useradmin domainuser add <user> -g administrators
where user is the Windows domain username for login.
Windows domain user provides more information on administering
domain users.
Specify either a NetBIOS domain or a Kerberos FQDN. The Kerberos
FQDN is a CTA server configuration setting, and if selected, the same
FQDN applies to all servers. Before selecting the Kerberos FQDN
option, follow steps in Configuring Windows for Kerberos to configure
your Fully Qualified Domain on the CTA.
EMC® Cloud Tiering Appliance Getting Started Guide
61
61
Step
Description
NDMP
Specific
Settings
For file migration, type the username and password for an NDMP user
on the NetApp source. By default, the port for NDMP traffic is 10000.
The NDMP user must belong to the backup operators group. To create
a user in the backup operators group, log in as root on the NetApp,
and type:
useradmin user add <user> -g "Backup Operators"
where user is the username for login.
The command will prompt for a password, but this is not the NDMP
password and is not used for the NDMP specific settings.
The NDMP password is automatically created when the user is
created. Use the NetApp CLI to retrieve the NDMP password by
typing:
ndmpd password <user>
where user is a user in the backup operators group. Use this
password for the NDMP specific settings.
For a NetApp filer, the root username and password can also be used
as the NDMP username and password. However for a vFiler, the
NDMP password is different from the root password. vFiler
configuration provides instructions on how to find the NDMP
password for the root user on a vFiler.
NetApp as
Source
This option configures the CTA to archive data from the NetApp filer.
If multiple appliances are connected to the same NetApp filer, only
one appliance should be configured with the NetApp as Source.
These options are not required if this NetApp is used as a
destination.
NetApp Local
Admin
Type the username and password of a user on the NetApp filer. The
user must be a member of the NetApp local administrator’s group.
This step
appears if
NetApp as
Source is
yes.
Directory
Exclusion
List
This step
appears if
NetApp as
Source is
yes.
62
62
These are the directories to exclude for all tasks that use scanning.
The CTA ignores all system directories such as, etc, lost+found, and
ckpt by default.
Verify that stub files are not in the excluded directories. CTA will not
access the excluded directories and the stub files will become
orphans.
EMC® Cloud Tiering Appliance Getting Started Guide
Step
Description
NetApp
FPolicy
callback
agents
The primary agent recalls all files when it is registered with the
NetApp. A secondary agent recalls files when the primary is
unavailable.
If the FPolicy callback agent is not explicitly configured as a
secondary agent, then it is a primary agent and the NetApp file server
will load balance between the registered primary agents.
This step
appears if
NetApp as
Source is
yes.
If no primary agents respond, then the NetApp filer will contact any of
the registered secondary agents. When one of the primary agents is
responsive again, the NetApp filer will automatically fail back to the
primary agent.
For the primary agent, select the agent that is on the same subnet as
the NetApp machine. For the secondary agent, select another agent
on the same subnet. If no such agent exists, select an agent on the
next physically closest subnet. Up to two secondaries are supported.
Primary or secondary agents may include CTA-HAs. If the CTA-HA is a
primary, the recall is load balanced between the CTA-HA and other
primary agents. If the CTA-HA is selected as a secondary, it is only
used for recall if the CTA goes down.
Review the Summary and click Finish to define the NetApp filer.
Verify the FPolicy configuration for CTA
After configuring the NetApp, FPolicy is normally configured automatically.
To confirm the FPolicy settings, type:
fpolicy
To verify that:
a.
FPolicy is enabled — Screen shows "CIFS file policy is enabled".
b.
rfpolicy is enabled — Screen shows "File policy rfpolicy (file screening) is
enabled".
c.
If an HA has been configured, the IP address is listed.
If the settings are not correct, manually configure the fpolicy settings with the
commands:
fpolicy create rfpolicy screen
fpolicy enable rfpolicy
fpolicy options rfpolicy required on
If there is a CTA-HA, manually configure it as a secondary FPolicy server with the
command:
fpolicy options rfpolicy secondary_servers <ip>
where ip is the IP address of the CTA-HA. If there are multiple CTA-HAs, separate
the IP addresses with commas.
EMC® Cloud Tiering Appliance Getting Started Guide
63
63
Deploying CTA with a VNXe
CTA supports the VNXe server as an archive destination. For file migration, CTA
supports the VNXe server as a destination when the source does not contain any stub
files.
Prerequisites for using VNXe as a file migration destination
To migrate files to a VNXe, ensure that the following conditions are satisfied:
•
For NFS, CTA has root access with read/write permission on destination
exports.
•
CIFS user has local administrator access on all destination shares.
•
VNXe does not support stubs so CTA stub aware migration to a VNXe is not
supported. To use a VNXe as a destination, recall all stubs to the source
before starting a migration.
•
For every server, properties are configured on the CTA for the NDMP username
and password
Adding VNXe to the CTA configuration provides details on configuring a VNX
server.
Adding VNXe to the CTA configuration
To configure CTA with a VNXe server:
In the navigation field of the web browser, type the IP address of the CTA. The CTA GUI
appears.
Type the username and password for the default account which are:
a. Username: admin
b. Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select VNXe. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the NetBIOS server name.
IP Addresses
Type the IP address for the VNXe:
When editing an existing server, click Update to retrieve the IP
address from the DNS that is based on the server name.
To specify an additional IP address, click Add.
To delete an existing IP address, select an IP and click Delete.
64
64
EMC® Cloud Tiering Appliance Getting Started Guide
Step
Description
CIFS Specific
Settings
This is the Windows domain user to be used by the appliance. The
domain user must be a member of the local Administrator group and
part of the Backup Operators group on the VNXe. Windows domain
user provides more information on administering domain users.
Specify either a NetBIOS domain or a Kerberos FQDN. The Kerberos
FQDN is a CTA server configuration setting, and if selected, the same
FQDN applies to all servers. Before selecting the Kerberos FQDN
option, follow steps in Configuring Windows for Kerberos to configure
your Fully Qualified Domain on the CTA.
NDMP
Specific
Settings
For file migration, type the username and password for an NDMP user
on the destination servers. By default, the port for NDMP traffic is
10000.
If no NDMP user exists on the VNXe, use the VNXe GUI to create a new
user with username and password.
Deploying CTA with Unity
To use CTA with Unity, perform the following configuration steps on the CTA.
CTA file archiving for Unity is supported by Unity version 4.1.x and higher. CTA block
archiving for Unity is supported by Unity version 4.2.x and higher.
With Unity as a source, CTA currently supports only archiving tasks. File migration
from or to Unity is not supported. When performing archive tasks from Unity, the
destination can only be cloud (Virtustream, AmazonS3, ECS/S3,or Azure).
Prerequisites for Unity as an archive source
To archive data from Unity, the CTA requires access to the Common API (TCP port
5080).
To archive NFS data, the CTA needs the following:
•
Mount v3 RPC service
•
NFS v3 RPC service
•
NLM v4 RPC service
•
Root access with read/write export permissions for all NFS data that will be
archived.
To archive CIFS data, the CTA needs SMB over NetBIOS (TCP port 139).
When configuring Unity properties on the CTA, plan to provide:
•
Credentials for Management and DHSM. These credentials are used for both
archive and recall.
•
Management IP address.
•
(For CIFS archiving only) The NetBIOS name of the Unity NAS server
credentials for the Windows domain user.
EMC® Cloud Tiering Appliance Getting Started Guide
65
65
When archiving, virus scanning can be enabled on the source, but scanning on read
can cause time-out conditions with no reply errors on the source if CTA is the first
application to access a file.
Configure name resolution for archiving
When the Unity needs to establish a connection to the appliance to recall file data
from a cloud service, it tries to resolve the FQDN from the HTTP DHSM connection in
its local hosts file. If it cannot be resolved locally, the NAS server will use DNS.
Note
Configuring CTA provides information on how to configure the CTA hosts file.
To use DNS:
Create a DNS entry for the callback daemon that points to the appliance.
As a best practice, the CTA hostname and ACD hostname should be different.
Using the same hostname for both can cause issues when trying to log into the
appliance.
Create multiple entries by the same name for each callback appliance.
For each entry that is created, select the checkbox for Create associated pointer
(PTR) record to ensure that it will be included in the Reverse Lookup Zones list.
Note
The Unity NAS server supports DNS HA failover. If the DNS server resolves the
callback daemon hostname to multiple IP addresses, the Unity NAS server
transparently switches to the server at the next available IP address.
DNS is the preferred method for name resolution. If using DNS is not feasible, use
local hostname resolution.
Configuring Unity to cloud archiving on the CTA
To archive from Unity to cloud storage, configure the cloud callback service so that
the CTA is in the recall path.
Configure the callback service to recall from the cloud
To configure recall from the cloud service (Virtustream, Amazon S3, or Azure):
From the console on the CTA, log in as root.
Type ! to escape to the command line and type:
\opt\rainfinity\filemanagement\bin\acdsetup init_rffm
Type n when the following message appears:
By default the Cloud Callback Daemon will connect to the CTA service
on the local machine.
Do you wish to configure another CTA? (y/n)
If there is a secondary callback agent such as a CTA-HA, log in on that agent as
root, and repeat steps 2 and 3. In step 3, type y to provide the IP address and root
password of the primary callback agent.
If an invalid IP address is provided, the ACD.log file, located in
/var/log/rainfinity/filemanagement/recall, will contain errors to indicate that
66
66
EMC® Cloud Tiering Appliance Getting Started Guide
there was no response from the primary agent. To correct the problem, repeat
steps 2 through 4 of this procedure.
Configuring automatically created DHSM connections for archiving
The CTA or CTAVE will automatically create DHSM connections for Unity systems
running OE version 4.1.x and higher.
When archiving any type of data to cloud storage server, recall requests will flow from
the Unity NAS server to CTA, CTA-HA, or CTAVE.
Adding a Unity file server to the CTA configuration
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the CTA account:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Unity under NAS File Servers. Click
OK.
For each step in the Create Server wizard, provide the required information.
Step
Description
Basic File
Server
Information
Type the NetBIOS server name.
IP Addresses
Type the Unity NAS server IP address:
When editing an existing server, click Update to retrieve the IP address
from the DNS that is based on the server name.
To specify an additional IP address, click Add.
To delete an existing IP address, select an IP and click Delete.
The Management IP is required for archiving. This allows CTA to
automatically perform some prerequisite tasks for archiving, as
described in Configuring automatically created DHSM connections for
file migration or archiving. If this field is empty, the CTA takes no
action, and you must perform the prerequisite tasks manually.
CIFS Specific
Settings
This is the Windows domain user to be used by the appliance. The
domain user must be a member of the local Administrator group and
part of the Backup Operators group on the Unity NAS Server. For more
information, see Windows domain user.
Specify either a NetBIOS domain or a Kerberos FQDN. The Kerberos
FQDN is a CTA server configuration setting, and if selected, the same
FQDN applies to all servers. Before selecting the Kerberos FQDN
option, follow the steps in Configuring Windows for Kerberos to
configure your Fully Qualified Domain on the CTA.
The CIFS credential is not required if the Unity system performs only
NFS archiving.
EMC® Cloud Tiering Appliance Getting Started Guide
67
67
Step
Description
Unity as
Source
This option configures the CTA to archive data from the Unity NAS
server. If multiple appliances are connected to the same Unity NAS
server, only one appliance should be configured with the Unity as
Source. This option is required only if the Unity is serving as a source
for archiving.
Multiple appliances can be configured to archive data from a single
Unity NAS server, but only one CTA or CTA/VE can be used to archive
data from a single file system.
The ACD DNS Name is required for archiving to a cloud storage server.
For the ACD DNS name, type the FQDN of the Cloud Callback DNS entry.
If a callback name is not specified, archive tasks to the destination will
not start. The FQDN is case-sensitive.
Unity
Callback
Agent
settings
This step
appears if
Unity as
source is yes
Directory
Exclusion
List
The directories to exclude for all tasks that use scanning. The CTA
ignores all system directories such as, etc, lost+found, and ckpt by
default.
Verify that stub files are not in the excluded directories. If they are in
the excluded directories, CTA will not access the excluded directories,
and the stub files will become orphans.
Review the Summary and click Finish to define the Unity file server.
Select Configuration and Common API Settings. The Common API Settings page
appears.
Type the username and password for Management Credentials and DHSM
Credentials under Unity Settings. CTA uses these credentials to create a
secondary HTTP DHSM connection using the REST API.
The Unity settings apply to all Unity servers configured on the CTA. If all Unity
servers are archive targets only, the Unity Settings are not required.
Adding a Unity block server to the CTA configuration
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Unity under Block Server. Click OK.
For each step in the Create Server wizard, provide the required information.
68
68
EMC® Cloud Tiering Appliance Getting Started Guide
Step
Basic Block
Server
Information
Description
Name
Name of the block server (Unity system).
Server FQDN
Fully Qualified Domain Name (FQDN) of the block
server. This should resolve to the Unity system
management IP address.
ISCSI Target
ISCSI Targets
Select the ISCSI targets.
Chap
Credentials
Use Hex Format
Username
Password
If the selected ISCSI targets require CHAP
credentials, select whether you want to use Hex
format for the CHAP password. Then type the CHAP
user name and CHAP secret
Mutual Chap
Credentials
Username
Password
If the ISCSI targets require mutual CHAP
credentials, type the CHAP user name and CHAP
secret.
Directory
Exclusion
List
The directories to exclude for all tasks that use
scanning. The CTA ignores all system directories
such as, etc, lost+found, and ckpt by default.
Verify that stub files are not in the excluded
directories. If they are in the excluded directories,
CTA will not access the excluded directories, and
the stub files will become orphans.
Review the Summary and click Finish to define the Unity block server.
Select Configuration and Common API Settings. The Common API Settings page
appears.
Type the username and password for Management Credentials and DHSM
Credentials under Unity Settings. CTA uses these credentials to create a
secondary HTTP DHSM connection using the REST API.
The Unity settings apply to all Unity servers configured on the CTA. If all Unity
servers are archive targets only, the Unity Settings are not required.
Create a policy for archiving Unity files or snapshots
Under Policies, select Policy and click Add. The Policy Wizard appears.
Configure policy settings. For archiving Unity files, select Archive as the policy
type. For archiving Unity snapshots, select Block Archive as the policy type.
To start defining rules for this policy, click Next. The Define Policy Rules Wizard
appears.
Click Add Rule.
For each expression you want to build, provide the settings and click Add.
When you are done defining expressions, click Next.
Fill in the settings for the archive destination and click Save Rule. Then Click Next.
Click Save Policy.
EMC® Cloud Tiering Appliance Getting Started Guide
69
69
Create a task to archive or restore Unity files
Use time-based scheduling to archive or restore a Unity snapshot to and from the
cloud (Amazon S3, ECS/S3, Azure, or Virtustream).
Under Schedule, click Add.
On the Schedule Wizard, select Archive.
Select the server type, name, protocol, and path of the file server that contains
the file to archive or restore.
Select the policy to use for archiving.
Select the archive destination and fill in the appropriate fields.
Fill in the fields for a Time Based schedule.
Click Finish.
Create a task to archive or restore Unity snapshots
Use time-based scheduling to archive or restore a Unity snapshot to and from the
cloud (Amazon S3, ECS/S3, Azure, or Virtustream).
Under Schedule, click Add.
On the Schedule Wizard, select the Block tab.
Select Block Archive or Block Restore and click Next.
Select the block server and the LUN or consistency group that contains the
snapshot to archive or restore.
Select the snapshot to restore and click Next.
Select the block server on which to restore the selected snapshot and click Next.
Fill in the fields for a Time Based schedule.
Click Finish.
Deploying CTA with Virtustream
CTA supports Virtustream cloud storage as an archiving destination.
Note
The Virtustream manager should provide you with the following settings:
Access Key ID, Secret Access Key, and Bucket Name.
Adding Virtustream to the CTA configuration
Configure the CTA with Virtustream.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
70
70
EMC® Cloud Tiering Appliance Getting Started Guide
On the Create Server page that appears, select Virtustream under Cloud Servers.
Click OK.
For each step in the File Server wizard, provide the required information and click
Next.
Step
Description
Basic File
Server
Information
Type the logical server name. Each file server is configured separately
with a unique name and is associated with a single Virtustream
bucket.
Web Service
Specific
Settings
URL — URL corresponding to the Virtustream bucket.
Access Key ID — Type the key that CTA uses to gain REST access to
the Virtustream bucket.
Secret Access Key — Type the secret credential used with the Access
Key ID.
Bucket Name — Type the Virtustream bucket destination where CTA
adds, deletes, or edits objects.
Review the Summary and click Finish to define the Virtustream.
Note
When archiving to the cloud (for example, to Atmos, Virtustream, Amazon S3,
or Azure), the CTA clock must be accurate and in sync with the cloud service.
Therefore, it is required to have an NTP server configured when archiving to
these destinations.
Deploying CTA with a Windows server
CTA supports the Windows 2003 and 2008 servers as a CIFS archiving destination or
as a file migration source. If migrating files from a Windows server, the EMCOPY and
LGDUP utilities must be installed on the Windows server before running the file
migration task.
Prerequisites for using Windows as a file migration source
To migrate files from Windows as a source, ensure that the following conditions are
satisfied:
•
The amount of free disk space on the Windows source is enough to hold a
snapshot of the volume during migration. To estimate the amount of space
required, estimate the amount of change to the data since the previous
snapshot. For example if 25% of the data has changed, ensure that 25% of
the disk space is free.
•
The amount of free disk space on the destination is enough to hold the source
data. If there is not enough disk space, the migration task will complete
without error, but some data will not be migrated.
•
CTA supports Windows cluster servers as a file migration source. However,
because the Microsoft Volume Snapshot Service (VSS) is not cluster aware, if
a failover occurs, the migration will fail.
EMC® Cloud Tiering Appliance Getting Started Guide
71
71
Adding a Windows server to the CTA configuration
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Windows. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the NetBIOS server name.
IP Addresses
Type the IP address for the Windows server.
When editing an existing server, click Update to retrieve the IP
address from the DNS that is based on the server name.
To specify an additional IP address, click Add.
To delete an existing IP address, select an IP and click Delete.
CIFS Specific
Settings
This is the Windows domain user to be used by the appliance. The
domain user must be a member of the local Administrator group and
part of the Backup Operators group on the Windows server. Windows
domain user provides more information on administering domain
users.
Specify either a NetBIOS domain or a Kerberos FQDN. The Kerberos
FQDN is a CTA server configuration setting, and if selected, the same
FQDN applies to all servers. Before selecting the Kerberos FQDN
option, follow steps in Configuring Windows for Kerberos to configure
your Fully Qualified Domain on the CTA.
Review the Summary and click Finish to define the Windows server.
Note
NDMP is not used for file migration from a Windows server as a source and
NDMP specific settings are not included as Windows properties.
Installing the EMWS copy agent for CTA
To perform CIFS file migration from a Windows source to a VNX or VNXe destination,
install the EMWS copy agent on the Windows server.
Log in to the Windows server as administrator with full backup, restore, and
security permissions.
Go to the EMC Online Support web site:
http://Support.EMC.com
To download the EMWS copy agent:
72
72
EMC® Cloud Tiering Appliance Getting Started Guide
a.
For CTA, select Downloads. Search for Cloud Tiering Appliance. Download
EMC CTA Migration Windows Service (EMWS).
b.
For CTA/VE, select Downloads. Search for Cloud Tiering Appliance/VE.
Download EMC CTA Migration Windows Service (EMWS).
To install EMWS type:
emws_V1_install /user <domain>\<user> /passwd <password> where domain is the
local machine name and user is an administrator. Both are required.
a. To update an installation, type: emws_V1_install
b. To uninstall, type: emws_V1_install/uninstall
Installing and running LGDUP
When running a Windows file migration task, CTA compares the local users and local
groups on the source with those on the destination. If any users or groups are missing
on the destination, the run will fail with a message written to the CTA file migration
log.
The LGDUP utility merges the users and groups from the source with the users and
groups on the destination. Install the LGDUP utility on the Windows machine and run
it to configure the users and groups on the source and destination before running a
file migration task.
Note
For VNXe, creation of local users is not supported, so CTA only migrates local
groups to VNXe. SID translation of local users to VNXe is not supported.
Log in to the Windows machine as administrator with full backup, restore, and
security permissions.
Go to the EMC Online Support web site:
http://Support.EMC.com
To download the LGDUP utility, select Downloads. Search for VNX. Download
CIFSTools.zip.
Unzip the file. In the resulting directory, click down to locate the lgdup.exe file.
Note
The LGDUP utility is a 32-bit command line application. If the Windows
server is running a 64-bit operating system, run LGDUP in 32-bit
compatibility mode.
To merge the local users and local groups database from the Windows source
with the destination and replicate privileges to the target:
a.
For migration to VNX, type:
lgdup.exe –v –u -l lgdup_log.txt \\<src_server_name>
\\<dst_server_name>
b.
For migration to VNXe, type:
lgdup.exe –v -l lgdup_log.txt \\<src_server_name>
\\<dst_server_name>
where src_server_name is the name of the Windows NetBIOS name and
dst_server_name is the name of the VNX or VNXe NetBIOS name.
EMC® Cloud Tiering Appliance Getting Started Guide
73
73
Deploying CTA with Isilon
CTA supports Isilon as a NAS destination for migration or archiving. To use CTA with
an Isilon, first configure the Isilon, and then configure the appliance.
Prerequisite tasks when using Isilon as a CIFS share destination
The Isilon must be part of a Windows domain or Active Directory. Verify that:
a.
Isilon and the CTA CIFS user are in the same domain, such as rain.prv.
b.
You are not in WorkGroup mode.
On a Windows machine that is part of the Isilon domain, create the destination
directory that CTA will use as a share. Security on the directory must allow full
control to the group Domain Admins and user Administrator. Administrator is the
same Windows domain user that will be used by CTA to archive to the Isilon.
a.
Log in to the Windows machine as administrator.
b.
Using Windows Explorer, create a directory in ifs/data. For example,
create CTADir.
c.
For folder CTADir, right-click Properties. The properties screen for that
directory appears.
d.
On the Security tab, click Add. For Windows 7 or 8, click Edit > Add. The
Select Users, Computers, or Groups screen appears.
e.
For Enter the object names to select, type the group Domain Admins.
Click Check Names. If the group name is found, it is underlined.
f.
Click OK. The properties screen reappears.
g.
For Allow, select Full Control. Click Apply.
h.
On the Security tab, click Add. The Select Users, Computers, or Groups
screen appears.
i.
For Enter the object names to select, type the username for the Windows
domain user to be used by the appliance as described in Windows
domain user. Click Check Names. If the user name is found, it will be
underlined.
j.
Click OK. The properties screen reappears.
k.
For Allow, select Full Control.
l.
Click OK.
For CTA to communicate with the Isilon using CIFS protocol, SMB service on the
Isilon must be enabled. Check the SMB service settings on the Isilon.
74
74
a.
In the navigation field of the web browser, type the IP address of the
Isilon. The Isilon Administration GUI appears.
b.
Log in to the Isilon with administrator privileges.
c.
Select File Sharing > SMB > Settings.
−
For Service status, verify that Enable is selected. If not, select it.
−
For Security mode, verify that User is selected. If not, select it.
EMC® Cloud Tiering Appliance Getting Started Guide
If any changes are made, click Submit.
From the Isilon console, verify that the NetBIOS Name Service (NBNS) is running.
a.
Check that the NBNS is enabled with the command:
isi services | grep nbns
b.
If the NBNS is not enabled, type:
isi services -a nbns enable
c.
Even if the NBNS is enabled, it may not be running. To verify that the
NBNS is running, check whether the Isilon is listening on port 139 with
the command:
netstat -an | grep LISTEN | grep 139
d.
If the Isilon is not listening on port 139, disable and re-enable the NBNS
with the commands:
isi services -a nbns disable
isi services -a nbns enable
e.
Recheck whether the Isilon is listening on port 139:
netstat -an | grep LISTEN | grep 139
From the Isilon Administration GUI, create a CIFS share for the CTA destination
directory.
a.
b.
c.
d.
Select File Sharing > SMB > Add Share.
−
For Share name, type the name of the share or export created, for
example, CTADir.
−
For Directory to share, click Browse. Select the path to the directory
created in step 2, for example, /ifs/data/CTADir. Click OK.
−
For Directory ACLs, select Do not change existing permissions.
Under Users and Groups, select Add. The Choose Users and Groups
screen appears.
−
For From the location, select the domain, such as rain.prv that was
referenced in step 1.
−
For Name, type Administrator. This is the same Windows domain user
that CTA will use.
−
Click Search. Search results list the Administrator user of the domain.
−
Select the Administrator user and click Choose. Under Users and
Groups, the Administrator is listed with the checkbox selected.
Click Edit permissions. The permissions screen appears.
−
Select Run as root. All permissions are set to Allow.
−
Click OK.
Click Submit. The SMB Summary appears with the share added.
EMC® Cloud Tiering Appliance Getting Started Guide
75
75
Prerequisite tasks when using Isilon as an NFS export destination
For CTA to communicate with the Isilon using NFS protocol, NFS service on the Isilon
must be enabled. First check the NFS service settings on the Isilon and then create
the NFS export for the CTA destination directory.
Note
Before creating the NFS export for the CTA destination directory, you must
configure the Isilon server so that it provides CTA with root CIFS access
permissions. You can do this running specific Isilon-specific CLI commands
that add "run-as-root" permissions for the CTA domain user on every Isilon
CIFS share used by CTA system. The following example shows Isilon CLI
commands used to do this for a single CIFS share:
Isilon v6.5:
> isi smb permission create -sharename='myShareName' --accountname='myDomain'\\'myUserName' --account-type=user -permission-type=allow --permission=run-as-root
Isilon v7.0:
> isi smb share permission create
'myShareName' 'myDomain'\\'myUserName' --run-as-root
In the navigation field of the web browser, type the IP address of the Isilon. The
Isilon Administration GUI appears.
Log in to the Isilon with administrator privileges.
Select File Sharing > NFS > Settings.
a.
For Service status, verify that Enable is selected. If not, select it.
b.
For NFSv4 Support, verify that Disable is selected. If not, select it.
If any changes are made, click Submit.
Select File Sharing > NFS > Add Export.
a.
Under Settings:
b.
For Directories, click Browse. Select the path to the directory. Click OK.
c.
For Permissions, select Enable write access and select Enable mount
access to subdirectories.
d.
Under Access Control:
e.
For User name, type root.
f.
For Group names, type everyone.
Click Submit. The NFS Summary appears with the export added.
Prerequisite task when using Isilon as a file migration destination
To configure CTA with Isilon as destination for file migration, an NDMP administrator
user on the Isilon is required.
In the navigation field of the web browser, type the IP address of the Isilon. The
Isilon Administration GUI appears.
Log in to the Isilon with administrator privileges.
76
76
EMC® Cloud Tiering Appliance Getting Started Guide
Select File System > Backup > NDMP Settings.
a.
Under Service, if the NDMP service is disabled, click Enable.
b.
Under Settings, port number 10000 is the default. This is the same port
number for the NDMP Specific Settings configured when Adding Isilon to
the CTA configuration.
c.
In the NDMP Administrators section, click Add administrator.
d.
For username, type ndmp_user. This is the same username that CTA will
use.
e.
For password, type a password. This is the same password that CTA will
use.
f.
Retype the password.
Adding Isilon to the CTA configuration
Configure Isilon properties on the CTA.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Isilon. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the NetBIOS server name.
IP Addresses
Type the IP address for the Isilon:
When editing an existing server, click Update to retrieve the IP
address from the DNS that is based on the server name.
To specify an additional IP address, click Add.
To delete an existing IP address, select an IP and click Delete.
If the Isilon cluster is configured using SmartConnect, add all IP
addresses configured for the cluster. CTA and Isilon SmartConnect
provides additional information about Isilon properties.
EMC® Cloud Tiering Appliance Getting Started Guide
77
77
Step
Description
CIFS Specific
Settings
This is the Windows domain user to be used by the appliance. The
domain user must be a member of the local Administrator group and
part of the Backup Operators group on the VNXe. Windows domain
user provides more information on administering domain users.
Specify either a NetBIOS domain or a Kerberos FQDN. The Kerberos
FQDN is a CTA server configuration setting, and if selected, the same
FQDN applies to all servers. Before selecting the Kerberos FQDN
option, follow steps in Configuring Windows for Kerberos to configure
your Fully Qualified Domain on the CTA.
If the Isilon is an NFS export destination only, this setting is not used.
NDMP
Specific
Settings
For file migration, type the username and password for an NDMP user
defined on the Isilon in Prerequisite task when using Isilon as a file
migration destination. By default, the port for NDMP traffic is 10000.
Review the Summary and click Finish to define the Isilon.
CTA and Isilon SmartConnect
When an Isilon cluster is configured to use EMC Isilon SmartConnect, Isilon load
balances SMB and NFS client access among a number of nodes in the cluster.
SmartConnect uses DNS delegation, allowing the DNS server to delegate authority for
the DNS name to a collection of IP addresses.
Isilon properties in CTA
Configuring Isilon properties on the CTA normally requires the NetBIOS name or
Kerberos FQDN and a single IP address that resolves to that name in DNS. However if
the Isilon server is configured to use SmartConnect, the CTA requires all the IP
addresses configured for the Isilon cluster. These include any address that can be
returned by a delegated DNS name to IP lookup serviced by the Isilon SmartConnect
Service IP for the cluster.
For example, if a three node Isilon cluster is configured to use SmartConnect with:
Isilon Cluster Name:
isilon1.mydomain.prv
Isilon SmartConnect Service IP: 10.4.0.89
Isilon SmartConnect Pool IPs:
78
78
10.4.0.80, 10.4.0.81,
10.4.0.82
EMC® Cloud Tiering Appliance Getting Started Guide
When configuring this Isilon cluster as in Adding Isilon to the CTA configuration, the
settings are:
NetBIOS server name:
isilon1
IP Addresses:
10.4.0.80, 10.4.0.81,
10.4.0.82
CIFS NetBIOS Domain or CIFS Kerberos FQDN:
mydomain.prv
Configure CTA with all the SmartConnect Pool IPs, but not the SmartConnect Service
IP (such as 10.4.0.89). The SmartConnect Service IP address is only used for DNS
delegation.
CTA will not be able to correctly load balance its access to the Isilon cluster if the
cluster’s IP Pool does not match the configuration in CTA. If Isilon nodes or
SmartConnect Pool IP addresses are added to or removed from an Isilon cluster, edit
the corresponding CTA configuration to add or remove the IPs.
DNS forward and reverse lookup
CTA requires forward DNS (name to IP) and reverse DNS (IP to name) lookups to be
configured correctly in your DNS server. Once the Isilon cluster, the CTA, and the DNS
server are configured for SmartConnect and DNS delegation, use the CTA CLI to File
configuration.
To verify that forward DNS lookup resolves the Isilon cluster name to one of the IPs
configured in the SmartConnect IP Pool, at the CTA CLI prompt, type:
nslookup <name>
If the Isilon cluster is configured using the SmartConnect round-robin option,
repeated nslookup name to IP requests should cycle through all the addresses
configured in the SmartConnect IP Pool.
For example, if a three node Isilon cluster is configured to use SmartConnect with:
Isilon Cluster Name:
isilon1.mydomain.prv
Isilon SmartConnect Service IP: 10.4.0.89
Isilon SmartConnect Pool IPs:
10.4.0.80, 10.4.0.81,
10.4.0.82
nslookup isilon1.mydomain.prv must resolve to one of the IPs: 10.4.0.80, 10.4.0.81,
or 10.4.0.82.
If nslookup fails or returns an IP that is not in the SmartConnect IP Pool, the DNS
server is not correctly configured to delegate to the Isilon SmartConnect Server IP. See
the Isilon documentation to configure forward DNS lookup and use nslookup to test
the configuration again.
EMC® Cloud Tiering Appliance Getting Started Guide
79
79
To verify that reverse DNS lookup resolves all of the IPs configured in the
SmartConnect IP Pool to the DNS name of the Isilon cluster, at the CTA CLI prompt,
type:
nslookup <IP>
For example:
•
nslookup 10.4.0.80 must resolve to isilon1.mydomain.prv
•
nslookup 10.4.0.81 must resolve to isilon1.mydomain.prv
•
nslookup 10.4.0.82 must resolve to isilon1.mydomain.prv
If any of these lookups fails to resolve correctly the DNS server’s reverse lookup zone
is not correctly configured. See the Isilon documentation to configure reverse DNS
lookup and use nslookup to test the configuration again.
Note
If either the forward DNS or reverse DNS lookup tests fail, do not use an Isilon
server configured with SmartConnect in CTA for archiving, repository
migration, or file migration.
Deploying the CTA with Data Domain
CTA supports the EMC Data Domain storage product as an NFS destination for
archiving and repository migration. CIFS source data can be exported and archived to
Data Domain through NFS while clients access the archived files through CIFS. The
stub file retains the CIFS attributes such as security settings and ADS.
Note
CTA supports Data Domain CIFS protocol starting from Data Domain 5.3.
However, CTA requires admin privileges to access CIFS shares and
successfully create all files on Data Domain.
Configure Data Domain server properties on the CTA.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Data Domain. Click OK.
80
80
EMC® Cloud Tiering Appliance Getting Started Guide
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the NetBIOS server name.
IP Addresses
Type the IP address for the Data Domain server:
When editing an existing server, click Update to retrieve the IP
address from the DNS that is based on the server name.
To specify an additional IP address, click Add.
To delete an existing IP address, select an IP and click Delete.
CIFS Specific
Settings
This is the Windows domain user to be used by the appliance. The
domain user must be a member of the local Administrator group and
part of the Backup Operators group on the VNXe. Windows domain
user provides more information on administering domain users.
Specify either a NetBIOS domain or a Kerberos FQDN. The Kerberos
FQDN is a CTA server configuration setting, and if selected, the same
FQDN applies to all servers. Before selecting the Kerberos FQDN
option, follow steps in Configuring Windows for Kerberos to configure
your Fully Qualified Domain on the CTA.
If the Data Domain is an NFS export destination only, this setting is
not used.
Review the Summary and click Finish to define the Data Domain.
Configuring a NAS-based repository
Any VNX, VNXe, Unity, Windows, Isilon, NetApp, or Data Domain system can be
configured as a NAS-based repository.
Note
The appliance must have read/write access to any share or export that may be
used as an archive source or destination. In addition, the appliance must
have read/write permission for any file that it may archive.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and NAS Repository. The NAS Repository List appears. Click
Add. The NAS Repository Properties dialog box appears.
You can either:
a.
Add an existing server and repository.
b.
Add a new server and repository.
EMC® Cloud Tiering Appliance Getting Started Guide
81
81
To add an existing server and repository, specify the following:
a.
Type — Select a type of NAS server from the list.
b.
Name — Select a file server of that type from the list.
Note
The file server must have a proper DNS entry defined that links the
file server name with the IP address.
c.
Protocol — Select NFS or CIFS. The source and repository protocol types
must match.
d.
If the source protocol is CIFS, the NAS repository protocol must be CIFS.
e.
If the source protocol is NFS, the NAS repository protocol must be NFS.
If the CIFS protocol is selected, use the CIFS user in the filesystem CIFS DHSM
connection string for CIFS specific settings when configuring the primary
storage on the appliance:
f.
Path — Click Browse to select an existing path.
Once the path is specified, a name in the form of Repository at <path> appears
in the Name field.
g.
Maximum limit of disk usage — Type a percentage value for disk usage.
Default value is 90%.
To add a new server, select the Type and click Add Server. Follow instructions to
add the server as outlined in:
a.
Adding VNX to the CTA configuration
b.
Adding NetApp filer to the CTA configuration
c.
Deploying CTA with a VNXe
d.
Deploying CTA with Unity
e.
Deploying CTA with a Windows server
f.
Deploying CTA with Isilon
g.
Deploying the CTA with Data Domain
Click OK to finish defining the NAS repository.
Deploying CTA with Amazon S3
Amazon Simple Storage Service (S3) is cloud storage. CTA supports Amazon S3 as an
archiving destination.
Note
The Amazon S3 account manager uses the Amazon Web Services (AWS)
Management Console to generate the Web Service Specific Settings which are
Access Key ID, Secret Access Key, and Bucket Name.
Adding Amazon S3 to the CTA configuration
Configure the CTA for an Amazon S3.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
82
82
EMC® Cloud Tiering Appliance Getting Started Guide
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Amazon S3. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the logical server name. Each file server is configured separately
with a unique name and is associated with a single Amazon S3
bucket.
Web Service
Specific
Settings
URL — URL corresponding to the Amazon S3 bucket as displayed in
the AWS Management Console.
Access Key ID — Type the key that CTA uses to gain REST access to
the Amazon S3 bucket. The Amazon S3 account manager generates
the key.
Secret Access Key — Type the secret credential used with the Access
Key ID. The Secret Access Key is generated with the Access Key ID.
Bucket Name — Type the Amazon S3 bucket destination where CTA
adds, deletes, or edits objects. The Amazon S3 account manager
configures the Amazon S3 bucket.
Review the Summary and click Finish to define the Amazon S3.
Note
When archiving to the cloud (for example, Atmos, Amazon S3, or Azure), the
CTA clock must be accurate and in sync with the cloud service. Therefore it is
required to have an NTP server configured when archiving to these
destinations.
Deploying CTA with Atmos
The Atmos cloud storage platform is an on-premise or service provider cloud. CTA
supports Atmos as an archiving destination, and as a source or destination for
repository migration.
Adding Atmos to the CTA configuration
Configure the CTA for an Atmos (or ViPR as Atmos).
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
EMC® Cloud Tiering Appliance Getting Started Guide
83
83
On the Create Server page that appears, select Atmos. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the name to identify the Atmos.
Web Service
Specific
Settings
DNS Name — Specify the name used to resolve the IP addresses in
the Atmos cluster.
Port — The GUI access method. HTTPS is the default and is typically
used when the Atmos is deployed remotely. Select HTTPS or HTTP to
specify the communication protocol. The default port number for
HTTPS (10080) or HTTP (80) automatically appears. If your Atmos
connects to HTTPS or HTTP through a different port, type the number.
Username — Type the UID within a given Subtenant on the Atmos.
CTA uses this UID to access storage on the cluster. If there is a
subtenant, specify the username as: <Subtenant_ID>/<UID>, where
Subtenant _ID is an alphanumeric string generated by the Atmos.
The UID is not the Tenant Name, the Subtenant Name, or the
Subtenant ID.
Password — Type the Shared Secret associated with the UID on the
Subtenant Information page of the Atmos.
Review the Summary and click Finish to define the Atmos.
Note
When archiving to the cloud (for example, Atmos, Amazon S3, or Azure), the
CTA clock must be accurate and in sync with the cloud service. Therefore it is
required to have an NTP server configured when archiving to these
destinations.
Installing the SSL certificate on the CTA
By default, the Atmos is configured without server-side authentication. However, the
Atmos administrator can install an SSL X.509 certificate on the Atmos to provide more
security to Atmos clients. If the certificate that is installed on the remote Atmos is
available to the CTA, the CTA can use the certificate to authenticate the Atmos before
archiving data to it. The CTA checks the DNS name in the certificate with the DNS
name of the Atmos configured on the CTA. If the DNS names match, authentication
succeeds.
To use the SSL X.509 certificate with the CTA:
•
The certificate must be in PEM file format. The Atmos administrator can
provide the file.
•
On the CTA, the name of the certificate must be atmos_trusted_CAs.pem
•
Install the certificate under:
/opt/rainfinity/filemanagement/conf/ATMOS_certs/<atmos_DNS>
84
84
EMC® Cloud Tiering Appliance Getting Started Guide
where atmos_DNS is the DNS name of the Atmos configured on the CTA. The
names are case-sensitive and must match exactly. Adding Atmos to the CTA
configuration provides details on configuring the DNS name on the CTA.
To run a CTA script that installs the PEM certificate file in the correct directory, type:
/opt/rainfinity/filemanagement/bin/atmoscert.pl
Deploying CTA with Azure
Microsoft Azure is cloud storage. CTA supports Azure as an archiving destination.
Adding Azure to the CTA configuration
Configure the CTA for an Azure.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Azure. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the name to identify the Azure.
Web Service
Specific
Settings
Container Name — Type the destination where CTA adds, deletes, or
edits objects. The Windows Azure Management Portal administrator
configures the containers associated with the storage account.
Account Name— Type the name of the Azure storage account that CTA
uses to gain REST access to the Azure container. The Windows Azure
Management Portal administrator creates this account.
Access Key — Type the key that CTA uses to gain REST access to the
Azure container. When a storage account is created, Windows Azure
generates primary and secondary access keys for that account. Either
key is valid.
Review the Summary and click Finish to define the Azure.
Note
When archiving to the cloud (for example, Atmos, Amazon S3, or Azure), the
CTA clock must be accurate and in sync with the cloud service. Therefore it is
required to have an NTP server configured when archiving to these
destinations.
EMC® Cloud Tiering Appliance Getting Started Guide
85
85
Deploying CTA with Centera
CTA supports the Centera as an archiving destination, and as a source or destination
for repository migration. Configure the CTA for an Centera.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
On the Create Server page that appears, select Centera. Click OK.
For each step in the File Server wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Basic File
Server
Information
Type the name to identify the Centera.
Access Node
Type the Centera access node name or IP address:
To specify an additional Access Node, click Add.
To delete an existing Access Node, select a node and click Delete.
The Access Node String is automatically generated when the Access
Node is added or deleted. You cannot type data directly into the field.
Centera
Authenticati
on Type
Select from one of the three choices:
User profile — If selected, type the username and password of the
Centera profile that is to be used for archiving.
PEA file — This option requires that a profile and pool entry
authorization (PEA) file was created to access Centera, and that a
copy of the PEA file resides on the CTA. If selected, the PEA file is
used to authenticate the CTA connection with Centera. Type the path
to the file on the local machine or browse for the file. A copy of the
file will be stored with the CTA configuration.
Anonymous — If selected, no security is used to authenticate with
Centera.
Review the Summary and click Finish to define the Centera.
Deploying CTA with ECS
ECS supports APIs, including ECS-CAS, ECS-S3, EMC Atmos, and NFS. CTA supports
ECS as an archiving destination.
86
86
EMC® Cloud Tiering Appliance Getting Started Guide
Adding ECS to the CTA configuration
Configure the CTA for an ECS.
In the navigation field of the web browser, type the IP address of the CTA. The CTA
GUI appears.
Type the username and password for the default account which are:
a.
Username: admin
b.
Password: rain
Select Configuration and Server. The Server List appears. Click Add.
ECS-CAS can be added to CTA as Centera. Refer to Deploying CTA with Centera for
deployment instructions.
ECS/S3 can be added to CTA as Amazon S3 or Virtustream. Refer to Deploying CTA
with Amazon S3 for deployment instructions.
Note
Manual port configuration changes might be needed on CTA, depending
on the ECS port configuration. Please contact support if needed.
ECS/ATMOS-REST can be added to CTA as an Atmos server. Refer to Deploying
CTA with Atmos for deployment instructions.
EMC® Cloud Tiering Appliance Getting Started Guide
87
87
Chapter 5
Maintaining the Cloud Tiering Appliance
This chapter contains the following sections:
Importing a file list archive ......................................................................... 90
Backing up the configuration ..................................................................... 94
Encryption Key restore in case of catastrophic failures ................................ 97
Maintaining the database .......................................................................... 98
Migrating from CTA to CTA/VE..................................................................... 99
Shutting down and restarting the appliance ............................................. 100
EMC® Cloud Tiering Appliance Getting Started Guide
89
89
Importing a file list archive
The CTA can perform archival tasks on lists of files imported from a third-party
software provider. To generate and import the file lists properly, the CTA administrator
and the third-party software administrator must exchange information as follows:
The third-party software administrator gives the CTA administrator the names of
the primary servers.
The CTA administrator:
a.
Adds the primary servers as source servers on the CTA as described in
Adding the primary servers.
b.
Configures an import provider with username and password as described
in Configuring the import provider.
c.
Configures an import file task as described in
d.
Configuring the import task.
The CTA administrator provides the server, provider, and task information to the
third-party software administrator.
With settings defined on the CTA, the third-party software generates an XML file
containing lists of files on a primary server that are to be archived.
Note
For optimum performance during file import, limit the XML file list to 1
million entries.
The XML file is transferred to the CTA as described in Importing the file list. Once
CTA validates the imported file, the import files archive task is queued to run.
Import files archive tasks are run in the same way as other archive tasks. The archive
destination is defined with the CTA policy. The source is defined in the imported XML
file list. Online help describes how to schedule and review results of an archive task.
Adding the primary servers
To archive files from the primary servers of the third-party software, configure the file
servers as a source on the CTA. A VNX Data Mover, Unity NAS server, or NetApp filer
can be a source. Details on how to add the file servers to the CTA configuration are
provided in:
•
Adding VNX to the CTA configuration
•
Adding a Unity file server to the CTA configuration
•
Adding NetApp flier to the CTA configuration
The CTA administrator gives the sever names to the third-party software
administrator.
Configure name resolution for archiving
When the Unity needs to establish a connection to the appliance to recall file data
from a cloud service, it tries to resolve the FQDN from the HTTP DHSM connection in
its local hosts file. If it cannot be resolved locally, the NAS server will use DNS.
90
90
EMC® Cloud Tiering Appliance Getting Started Guide
Note
Configuring CTA provides information on how to configure the CTA hosts file.
To use DNS:
Create a DNS entry for the callback daemon that points to the appliance.
As a best practice, the CTA hostname and ACD hostname should be different.
Using the same hostname for both can cause issues when trying to log into the
appliance.
Create multiple entries by the same name for each callback appliance.
For each entry that is created, select the checkbox for Create associated pointer
(PTR) record to ensure that it will be included in the Reverse Lookup Zones list.
Note
The Unity NAS server supports DNS HA failover. If the DNS server resolves the
callback daemon hostname to multiple IP addresses, the Unity NAS server
transparently switches to the server at the next available IP address.
DNS is the preferred method for name resolution. If using DNS is not feasible, use
local hostname resolution.
Configuring Unity to cloud archiving on the CTA
To archive from Unity to cloud storage, configure the cloud callback service so that
the CTA is in the recall path.
Configure the callback service to recall from the cloud
To configure recall from the cloud service (Virtustream, Amazon S3, or Azure):
From the console on the CTA, log in as root.
Type ! to escape to the command line and type:
\opt\rainfinity\filemanagement\bin\acdsetup init_rffm
Type n when the following message appears:
By default the Cloud Callback Daemon will connect to the CTA
service on the local machine.
Do you wish to configure another CTA? (y/n)
If there is a secondary callback agent such as a CTA-HA, log in on that agent as
root, and repeat steps 2 and 3. In step 3, type y to provide the IP address and root
password of the primary callback agent.
If an invalid IP address is provided, the ACD.log file, located in
/var/log/rainfinity/filemanagement/recall, will contain errors to indicate that
there was no response from the primary agent. To correct the problem, repeat
steps 2 through 4 of this procedure.
Configuring automatically created DHSM connections for archiving
The CTA or CTAVE will automatically create DHSM connections for Unity systems
running firmware version 4.1.x and higher.
When archiving any type of data to cloud storage server, recall requests will flow from
the Unity NAS server to CTA, CTA-HA, or CTAVE.
EMC® Cloud Tiering Appliance Getting Started Guide
91
91
Note
File systems with Unity File Level Retention (FLR) enabled cannot be used as
an archiving source.
•
Adding a Unity block server to the CTA configuration
•
Adding NetApp filer to the CTA configuration
The CTA administrator gives the server names to the third-party software
administrator.
Configuring the import provider
To copy an archive file list to the CTA, the third-party software provider must have
permission to write to the CTA. The import provider is a unique Linux user on the CTA
that has limited security access to a staging directory. When the provider is
configured, CTA creates the staging directory for the imported XML file.
Select Configuration and Import Provider. The Import Provider List appears.
Click Add. The Import Provider Properties page appears.
Specify the following:
a.
Username — Type a name for the user that is allowed to log into the CTA
from the provider. This must be a valid Linux user name. The third-party
software uses the name for the provider in the XML file that it creates.
b.
Password — Type a password used to log into the CTA from the provider.
Click Commit to define the Provider.
The CTA administrator gives the name and the password to the third-party software
administrator.
Configuring the import task
For the CTA to operate on the imported file list, the header of the XML file must
contain a task name configured on the CTA. The CTA matches the name in the header
of the XML file to an import files archive task.
Configure an import files archive task based on an archive policy. Files are archived to
the destination defined in the policy.
Select Schedule and click Add.
For each step in the Schedule wizard, provide the required information indicated
with a red asterisk and click Next.
Step
Description
Task Type
On the Archive tab, select one of the archive task types.
At the bottom of the screen, check the box to Import file list provided
by an external provider.
92
92
Import File
Task
Type a task name. Select the import provider defined in Configuring
the import provider.
Policy
Click Add Policy.
EMC® Cloud Tiering Appliance Getting Started Guide
Step
Description
Define Policy
Parameters
Select an archive policy type: archive, multi_tier, or multi_tier_stub.
Define Policy
Rules
Click Add Rule.
Define a
Policy Rule
To archive all files in the imported list, build an expression with:
Type a policy name.
File Attribute: Size
Operator: >=
Value: 1
Unit: Bytes
Click Add.
Leave the default action of Archive.
Select the
Archive
Destination
Select a destination. Click Save Rule.
Define Policy
Rule
The Define Policy Rules page reappears with the new rule added.
Verify Policy
Rule
After verifying the policy definition, click Save Policy.
Policy
The Policy page reappears with the new policy added.
Schedule
Select the time-based Schedule Type for the import task: Import,
Daily, Weekly, Monthly or Future. The task will not run until the XML
file list is imported and validated.
After verifying the task definition, click Finish.
The CTA administrator gives the task name to the third-party software administrator.
Importing the file list
To transfer the file list to the CTA, the CTA imports the XML file or the import provider
copies the XML file to the CTA.
CTA imports the file
If the XML file list is in a location that is accessible by the CTA, you can use the CTA
GUI to import the file:
Select Schedule, and show schedules of type Import Files.
Highlight the import task defined in
Configuring the import task. Click Import and select the Import File option.
In the Explorer window that appears, select the XML file and click Open.
Import provider copies the file
If the import provider is copying the XML file to the CTA, it uses the name and
password assigned by the CTA administrator in Configuring the import provider to log
in to the CTA. The XML file list is deposited into a staging directory as:
EMC® Cloud Tiering Appliance Getting Started Guide
93
93
/opt/rainfinity/filemanagement/import/providers/<PROVIDER>/import_
files_<ID>.xml
where PROVIDER is the logical name of the provider defined in CTA and ID is the
unique ID in the XML file.
Validating the import file
Every 30 seconds, the CTA scans for imported file lists. Before launching import file
archive task, the CTA checks the imported XML file to confirm that it has matching
values for:
•
provider name
•
task name
•
file server names
The CTA also verifies that it can access all shares and exports listed in the XML file.
If any validation checks fail, an error is reported in the import log. To review import
logs before running the import file archive task:
Select Schedule, and show schedules of type Import Files.
For any import file archive task defined, click Import and select the Import Logs
option.
Each row corresponds to an XML file list import. On any row where the status
shows a validation error, click View Log to display the log. The text file that
appears will list problems with the XML file.
The logs for the XML file list import are also accessible outside of the GUI:
/opt/rainfinity/filemanagement/import/providers/<PROVIDER>/log
where PROVIDER is the logical name of the provider defined in CTA.
Backing up the configuration
The CTA and CTA/VE contain configuration information and critical database tables.
The CTA-HA contains no persistent data. If data on a CTA-HA is lost, the CTA-HA
software must be reinstalled as described in Performing a CD clean install on the
appliance.
If data on a CTA or a CTA/VE is lost, the software must be reinstalled and the last
backup copy of the configuration and database tables must be restored. For this
reason, backup the CTA or CTA/VE configuration and the critical database tables
nightly.
Note
Task and simulation log files are not included in a backup. To preserve these
files, copy the /opt/rainfinity/filemanagement/log/fws directory to secure
storage either periodically or before performing a CD clean install.
The backup feature uses the following process:
•
94
94
Critical CTA system configuration data is backed up to a gzipped tar file (.tgz).
EMC® Cloud Tiering Appliance Getting Started Guide
•
The tar file is written to a destination on an Centera or NAS repository.
To perform disaster recovery, the CTA uses a catalog file (DBBackup.out) to locate tar
files on the destination and to reconstruct the CTA system configuration after a
disaster. The catalog file is stored on both the CTA and in a secondary disaster
recovery location.
Creating a backup dump
Regular backups may be scheduled to run automatically.
Select Configuration and Backup and Recovery Settings.
Under File Management Backup Destination, specify:
a.
The number of backups — The default value is 5.
b.
Select Destination — The Centera or NAS repository where the backup
files will be stored. The backup files are gzipped tar files (.tgz) that
contain CTA system configuration data.
Note
Only NFS NAS repositories are listed as backup destinations.
CIFS NAS repositories are not supported as backup destinations
and are not listed.
With NAS repositories, the data is stored with a directory structure that is
similar to that of an archive destination.
c.
Note
Select Disaster Recovery Location — The NFS export where the backup
catalog file (DBBackup.out) will be stored. The DBBackup.out file is also
stored on the CTA. The file stored on the NFS export is only used if the file
stored on the CTA is lost or damaged.
Ensure that the selected location is only assigned to one CTA. Multiple CTAs
must not use the same disaster recovery location.
Select Schedule and click Add. The Schedule Wizard appears.
On the Auxiliary tab, select Backup. Click Next.
For backup tasks, time-based is the only schedule selection. Select the daily,
weekly, or monthly recurring time for backups to run.
To perform a nonrecurring backup, or to perform a backup immediately, run the
script:
fmbackup
When the backup is complete, the system returns the message:
Done.
The backup has been output into /tmp/DUMPFILE.
where DUMPFILE is a unique filename generated by the backup script.
Restoring a backup dump
Backups are typically restored after a system failure. To restore a backup, start with a
freshly installed appliance. Steps are performed from both the GUI and the command
line.
EMC® Cloud Tiering Appliance Getting Started Guide
95
95
Configure networking. Configure the CTA network provides details.
Configure the hostname, domain, and DNS servers. Configure the hostname,
domain, and DNS server provides details.
Configure the destination for the restored backup files (.tgz).
a.
If the backup files were written to Centera, configure Centera as the
destination for the restored files. Deploying CTA with Centera provides
details.
b.
If the backup files were written to a NAS repository, configure a NAS
repository as the destination for the restored files. Configuring a NASbased repository provides details.
Mount the NFS export where the backup catalog file (DBBackup.out) is stored.
This is the disaster recovery location described in Creating a backup dump.
Copy DBBackup.out to /opt/rainfinity/filemanagement/conf.
From the GUI, select Configuration and Backup and Recovery Settings.
Under Recover File Management, select the .tgz file to restore and click Restore.
Using information from the DBBackup.out file, the .tgz backup file will be restored
to the /var/fmrestore location.
The fmrestote script reconstructs the CTA system configuration from the .tgz file
restored in step 6.
To run the script in a screen session that will not be interrupted, type:
screen
fmrestore <backup_file.tgz>
As the restoration occurs, the system will prompt for input to:
a.
Confirm restoration.
b.
Start the FPolicy callback service for a NetApp.
c.
Start the callback daemons for VNX and for the cloud service.
At each prompt, type y. When asked if you want to add another server, type n.
Note
The database tables are restored at a rate of approximately 10 million entries
per hour.
If restoring data to the same machine, the CTA automatically restarts at the
conclusion of the restoration process. If restoring data to a different machine, the CTA
must be manually restarted. Also, original network configuration files, such as
/etc/hosts, may need to be manually edited to reflect the new IP and hostname of the
new machine.
96
96
EMC® Cloud Tiering Appliance Getting Started Guide
Typical output of the fmrestore script is as follows:
[root@fm2 bin]# fmrestore /var/fmbackup_9.0_cta.Thu_26-0112_16_41.tgz
Expanding /var/fmbackup_9.0_cta.Thu_26-01-12_16_41.tgz in /var...
This will overwrite your configuration and database. Are you sure?
Press 'y' to continue or 'n' to abort now
y
Stopping CTA GUI ...
Stopping Tomcat server
Tomcat server stopped
Stopping filemanagement daemon ...
Stopping filemanagement daemon watchdog
Stopping filemanagement daemon done
done
Empty the current database...
Removing Unique key constraints ...
Restore configuration and database...
Starting network time protocol daemon (NTPD) done
Warning: backup is missing file: /etc/sysconfig/network
Adding Unique key constraints ...
Updating Database index statistics...
Starting CTA GUI ...
Starting Tomcat server
Tomcat server started
Starting filemanagement daemon ...
Starting rslogd (already running): done
Starting rslogd Monitor (already running): done
Starting rslogd cpu check (already running): done
Starting filemanagement daemon done
Starting filemanagement daemon watchdog done
done
Restore Done..
Encryption Key restore in case of catastrophic failures
If CTA experiences a catastrophic failure (that is, a hardware failure) and must be
restored from backup, you must take special care to ensure that keys are not lost.
Recovery of the Main CTA
It is possible that keys were generated and replicated after the most recent backup
was created. In this case, restoring the keystore from backup would result in keys
being lost. If these keys had previously been used to encrypt archived files, the
contents of those files will be unrecoverable by the main CTA. Use the krd executable
EMC® Cloud Tiering Appliance Getting Started Guide
97
97
in command line mode by the system administrator to recover the keystore from the
CTA-HA, which is presumed to have the most recent copy. The krd will ensure that a
local keystore will not be overwritten with a new keystore that contains fewer keys
than the original.
Recovery of the CTA-HA
No special action is necessary. The main CTA is presumed to have the most recent
copy of the keystore. Use the krdsetup script as if the CTA-HA is being installed for the
first time.
Maintaining the database
After archiving millions of files, archiving tasks may become slow as the number of
entries in the archival database grows larger. To improve performance, use a CTA
vacuum process to clear the database of unused entries and reindex the entries that
remain.
The database maintenance process can take several hours. While the process is
running, the filemanagement daemon must be halted and the GUI may not be used.
System administrators should plan to run database maintenance when the appliance
is not needed.
Recalls are not interrupted by database maintenance.
Checking database size and disk capacity
Before performing database maintenance, verify that the maintenance is warranted.
Check the current database size. Click the Archived Files tab:
Check how much disk space the database is using by typing:
du -sh /var/lib/pgsql/data/base
The database should use about 1 million archived files per gigabyte. If the database
is using more than twice the expected disk space, for example, if 1 million archived
files are occupying more than 2 gigabytes, perform database maintenance.
Performing database maintenance
The command line script that starts database maintenance performs the following
steps:
Stops the filemanagement daemon and GUI.
Runs the database vacuum process.
Restarts the daemon and the GUI.
Database maintenance can be run immediately as a CTA task or scheduled to run at a
specific time.
Note
•
Before running the CTA vacuum process, it is recommended that you backup
the CTA system and copy the backup file to an off-host location.
To start the CTA vacuum process immediately, type:
rffm doDBMaintenance
98
98
EMC® Cloud Tiering Appliance Getting Started Guide
•
To schedule the CTA vacuum process to start at a later time and to run
repeatedly, type:
rffm scheduleVacuumTask VacuumStartTime=<StartTime>
VacuumWeekRepetition=<Number_of_weeks>
where:
a.
StartTime is the date and time when the first vacuum task will run. The
format is yyyy-mm-dd hh:mm:ss. After each run, the value is reset to the
date and time of the repeat run.
b.
Number_of_weeks is the number of weeks between runs. It is specified
as an integer and the value should be between 4 and 24. The default is
8.
Every 30 minutes, CTA checks to see if there are any vacuum tasks scheduled.
One hour before the vacuum task is scheduled to start, CTA sends the alert “A
VACUUM TASK WILL START WITHIN THE NEXT 1 HOUR”.
For example, to start the CTA vacuum process at 2 a.m. on May 1, 2011 and run
the task every four weeks, type:
rffm scheduleVacuumTask VacuumStartTime="2011-05-01 02:00:00"
VacuumWeekRepetition=4
•
c.
At or around 1 a.m. on May 1, 2011, CTA sends the alert that the vacuum
process will start within the hour.
d.
Following the run, the StartTime is reset to at 2 a.m. on May 29, 2011.
To delete the CTA vacuum process, type:
rffm deleteVacuumSchedule
The log of the process is: /var/lib/pgsql/vacuum.log
The output of the process is:
/opt/rainfinity/filemanagement/conf/DBMaintenance.log
Migrating from CTA to CTA/VE
The procedure to migrate from CTA to CTA/VE involves backing up the CTA database
and restoring it to a CTA/VE. The migration path consists of the following steps:
Note
Migration can only occur between systems running the same CTA versions (for
example, between two systems running CTA 12.0 to 12.0). If two systems are
running different CTA variants, one or both should first be upgraded so that
they are running the same variant before migration occurs.
Upgrade the FMA to CTA version 7.5 or later.
Back up the current FMA configuration to a Centera or NAS repository. If
preserving additional custom configuration or task simulation and support logs,
back up the files separately.
Install CTA/VE version 7.5 or later on the ESX Server and configure networking.
Copy the backup file to the CTA/VE.
EMC® Cloud Tiering Appliance Getting Started Guide
99
99
Shutdown the FMA. Remove it from the network.
Manually reconfigure the IP address of the CTA/VE to replace the CTA on the
network.
Restore the backup file on the CTA/VE.
Reboot the CTA/VE.
Note
The network bonding feature, which is available on the CTA, is not available
on the CTA/VE.
If a CTA is being upgraded to CTA/VE, and the VNX or NetApp implementation
includes a CTA-HA for recall:
Use the CTA-HA to provide recall functionality while upgrading the CTA to CTA/VE.
Once recall has been tested and verified for the CTA/VE following the upgrade:
a.
Use the CTA-HA to provide recall for the CTA/VE, or
b.
Install a CTA/VE-HA to provide recall for the CTA/VE
Shutting down and restarting the appliance
To shut down and restart a working CTA or CTA/VE:
Stop any running tasks.
Stop all services with the commands:
filemanagement stop
celerracallback stop
atmoscallback stop
fpolicycallback stop
If an HA appliance is deployed, verify that the HA appliance has taken over file
recalls by attempting to open an archived file.
Either shut down or reboot the appliance.
a.
To shut down the appliance, type the command:
shutdown -h now
b.
To reboot the appliance, type the command:
reboot
For the CTA-HA, only the callback services are stopped. The filemanagement stop
command is not used.
100
100
EMC® Cloud Tiering Appliance Getting Started Guide
Chapter 6
Cloud Tiering Appliance System Settings
This chapter presents the following topic:
Security hardening .................................................................................. 102
Configuring the GUI access method .......................................................... 105
STIG hardening ........................................................................................ 105
LDAP client configuration ......................................................................... 107
Certificate management ........................................................................... 111
Appliance mail delivery settings ............................................................... 111
Log settings ........................................................................................... 112
Configuring alerts .................................................................................... 114
System command accounting .................................................................. 116
Windows domain user ............................................................................. 118
SID translator .......................................................................................... 120
Error! No text of specified style in document.
Error! No text of specified style in document.
101
Security hardening
By default, security hardening is not enabled.
To configure security hardening:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security. A set of security settings options appears.
Select Harden Appliance.
The default settings for the items that affect the appliance security level are:
a.
Use single security database =no
b.
Disable root logins =no
c.
Strengthen passwords =no
d.
Age passwords =no
e.
Harden to STIG requirements =disabled
When all four settings are “no,” security hardening is disabled and this disabled
security level is referred to as the default level.
If any of the settings is set to a non-default value, security hardening is enabled.
Note
In addition to the security settings, the GUI access method may also be
configured from the Harden Appliance menu. By default, the GUI is accessible
over both http and https. Enabling https only or redirecting http to https does
not change the appliance setting to hardened.
Single security database
If the single security database setting is enabled, all authentications on the device
will go through standard Linux Pluggable Authentication Modules (PAMs). This
applies to both GUI and CLI access.
Both the GUI and the CLI provide two types of users:
•
Admin users belonging to the wheel group and Rainfinity groups
•
Ops users belonging to the Rainfinity group
CLI users are configured independently from the GUI users.
If rfhsetup is used to enable the security database setting option, existing GUI users
will not be able to log in. Use rfhsetup to disable root logins, and then create the new
user.
To disable root logins:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security. A set of security settings options appears.
Select Harden Appliance.
Select Configure root login settings.
For Allow login as root?, select N.
102
102
EMC® Cloud Tiering Appliance Getting Started Guide
Note
Once root login is disabled, you must log into the CTA with the new username
and password to use the CLI.
Admin users
An admin user who is a member of the wheel group and logged in through SSH can
become a superuser to:
•
Create/delete other users
•
Run rfhsetup
To add an admin user for access from the CLI:
Log in to the CTA as root.
Type the following commands:
useradd –G rainfinity,wheel <username>
passwd <username>
Ops users
An ops user belongs to the Rainfinity group.
To add an ops user for access from the CLI:
Log in to the CTA as root
Type the following commands:
useradd –G rainfinity <username>
passwd <username>
Linux PAM users
A Linux PAM user is created through the CLI. When a Linux PAM user is logged in to
the GUI with the single security database setting enabled, the user’s role (admin or
ops) is cached for the duration of the session.
If the administrator changes the user’s setting while the user is logged in, the user’s
role will not be refreshed until one of the three following conditions occurs:
•
User logs out.
•
GUI is restarted.
•
Cached user information in the Tomcat server expires due to inactivity.
Adding users with the GUI
To add a new admin or ops user with the GUI:
Log in as admin.
From the Configuration tab, select Cloud Tiering Appliance Users.
Select Add a New User. In the Cloud Tiering User Properties dialog box that
appears:
a.
Type the name.
b.
Type a new password.
c.
Specify the type of user:
EMC® Cloud Tiering Appliance Getting Started Guide
103
103
Note
−
Super User — The admin user.
−
Regular User — The ops user.
When the single security database setting is disabled, users created through
the GUI are allowed to log in through the GUI but not the CLI. In addition, if the
single security database setting is enabled, user accounts cannot be created
through the GUI. If the user attempts to invoke the configuration page for
Cloud Tiering Appliance Users, a warning appears.
Disable root logins
If root logins are disabled, the only way to add new users or to run rfhsetup is for an
admin user (such as a user who belongs to the wheel group) to log in to the device,
and then become a root user.
When the setting to disable root logins is being changed to yes, the CTA checks to
ensure that:
•
There is at least one admin user other than root who belongs to the wheel
group. This user must have a configured password.
•
The wheel users are in the local /etc/group file. The CTA ignores LDAP users
while performing this check because LDAP servers occasionally become
unreachable.
Note
Configure a small set of admin users locally for each CTA. Most admin and
ops users are configured on an LDAP server. In this way, the management of
these users scales to large networks.
Strengthen passwords
If the passwd command is run with password strengthening enabled, your new
password must be at least eight characters long and satisfy the following
requirements:
•
At least three characters are different from the previous password.
•
At least one character is an uppercase letter.
•
At least one character is a number.
•
At least one character is a special character.
In a clustered environment, run the passwd command on both the primary and
backup nodes.
Note
104
104
The root user can change any password including its own to any value,
regardless of the password strengthening setting to strengthen it.
EMC® Cloud Tiering Appliance Getting Started Guide
Age passwords
If password aging is enabled, every user (except root) who can log in with a shell
account will have an aging password. The root user configures:
•
When to print a user warning that a password is about to expire.
•
The maximum number of days a password can remain valid before it must be
changed.
•
How often a password may be changed.
•
The number of days following password expiration after which the account
will be locked. Once an account is locked, only the root user can unlock the
account by using the change command to change the age of the password.
Note
If a large number of devices are deployed, a central authentication service
(such as LDAP) should be used. Password administration through the central
site greatly facilitates user scalability, as one user is not required to log in to
every deployed CTA to update an aging password.
Configuring the GUI access method
By default, the GUI can be accessed by both HTTP and HTTPS. To change this for the
CTA:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security. A set of security settings options appears.
Select Harden Appliance.
Select Configure GUI access method:
a.
To disable access over HTTP, select Only enable GUI access over https.
b.
To redirect http traffic to HTTPS instead of disabling HTTP, select Redirect
GUI access over http to https.
STIG hardening
Security Technical Implementation Guide (STIG) is a set of security guidelines issued
by the US Department of Defense. These STIG UNIX guidelines define how UNIX/Linux
appliances should behave from a security standpoint.
Enabling STIG hardening
The CTA provides an option for hardening the appliance to meet the UNIX STIG Guide
(Version 5, Release 1). When STIG hardening is enabled, the security settings change
as follows:
•
The user must type the root password to gain access to the CTA in single user
mode.
•
After three consecutive login attempts, the account is disabled.
•
Only the root user can reenable a disabled account.
EMC® Cloud Tiering Appliance Getting Started Guide
105
105
•
The login delay between login prompts increases from 2 to 4 seconds.
•
New passwords are required to be a minimum of nine characters in length.
•
When changing passwords, the past five passwords cannot be reused as the
new password value.
•
The root account’s home directory will be set to a permission value of 700.
•
Man page file permissions will be set to 644.
•
User-directories must not contain undocumented startup files with
permissions greater than 750 (that is, they must allow write access only for
that user).
•
The system and default user umask must be set to 077.
•
Access to the cron utility will be restricted using the cron.allow and cron.deny
files.
•
Crontab file permissions above 700 will not be permitted (in the
/etc/cron.daily, /etc/cron.hourly, /etc/cron.weekly directories).
•
The inetd.conf file permissions will be set to 440.
•
Unnecessary accounts, for example, games and news will be deleted.
•
sysctl.conf file will be set to 600 permission.
To enable STIG hardening on the CTA and CTA-HA:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security.
Select Harden Appliance.
Select Harden to STIG requirements.
When prompted with Enable changes to conform to STIG Hardening
requirements?, Type y.
Disabling STIG hardening
When STIG hardening is disabled, the security settings change as follows:
•
No password prompt is made prior to connecting in single-user mode.
•
User accounts are unlocked, even after three or more failed login attempts.
•
The login delay is set to the current default setting, which is less than four
seconds at this time.
•
When changing passwords, the minimum length must be:
•
106
106
a.
If password hardening is enabled: eight characters, with at least one
lowercase, one uppercase, one digit, and one special character.
b.
If password hardening and STIG hardening are disabled: the minimum
requirements for the new password is that it should be six characters
long.
When STIG hardening is disabled, the user can reuse previously set
passwords.
EMC® Cloud Tiering Appliance Getting Started Guide
•
The /root directory permissions is reset to 750.
•
Man page file permissions remain at 644. That is, this STIG hardening change
is retained.
•
User-directory permissions remain at the value prior to STIG hardening.
•
The system and default user umask must be set to 022.
•
Unnecessary groups/accounts that are deleted during STIG hardening remain
deleted even after STIG hardening is disabled.
•
Access to the cron utility is unrestricted using the cron.allow and cron.deny
files.
To disable STIG hardening on the CTA:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security.
Select Harden Appliance.
Select Harden to STIG requirements.
When prompted with Enable changes to conform to STIG Hardening
requirements?, Type n.
STIG hardening is disabled when the appliance hardening level is reset to the default
level as follows:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security.
Select Remove Appliance Hardening Settings.
LDAP client configuration
LDAP directory trees represent hierarchical directory information, such as people and
phone numbers that belong to an organization. The CTA supports Lightweight
Directory Access Protocol (LDAP) for user authentication and authorization.
Global LDAP settings
Global LDAP settings affect all LDAP operations. The following settings impact how
the LDAP client on the CTA behaves if the LDAP server does not respond.
Bind type
There are two types of binds:
•
Hard — The CTA continues to retry the bind attempt until a maximum timeout
is reached.
•
Soft — The CTA attempts to bind once and abort if the server does not
respond.
EMC® Cloud Tiering Appliance Getting Started Guide
107
107
Time limits
There are two types of time limits:
•
Search time limit — The amount of time for which the LDAP client waits for an
initial response from the server.
•
Bind time limit — The amount of time for which the LDAP client attempts to
bind.
By default, these time limits are set to 10 seconds to allow the appliance to
remain responsive when the LDAP server is down, and to fail over to an alternate
authentication mechanism, if another mechanism is configured.
Server type
The CTA LDAP client works with the following types of LDAP servers:
•
OpenLDAP
•
Active directory with RFC 2307 support
Identity Management for Unix should be installed on the ActiveDirectory
server for CTA to be able to authenticate an ActiveDirectory user. The AD user
used to log into CTA must have the NIS domain setup correctly on the AD
server. The user should be added to the wheel and rainfinity groups to have
administrator privileges.
LDAP authentication
When LDAP is configured, LDAP authentication is established through a sequence of
events.
•
A user connects to the CTA. The user is challenged for to authenticate.
•
The CTA LDAP client contacts the LDAP server to validate the user’s
credentials.
•
To validate that the client is trusted, the server attempts to establish a secure
communication channel with the client and then authenticate by using a
plain-text password or SASL.
The client does the following to establish the secure communication channel:
a.
Requests the server’s public key.
b.
Validates that the server’s public certificate is signed by a known
Certificate Authority (CA).
c.
Encrypts its data using the server’s public certificate. Only the private key
stored on the server can decrypt this data.
Initial data from the client contains negotiation information that the server
and client use to establish a secure communication channel.
Just as the client uses the server’s public key to encrypt its first message, the
server ensures that the client is authentic by requesting the client’s public
certificate and validating that it is signed by a known Certificate Authority.
After the secure channel is established, the password is exchanged. If SASL is
configured, it can be used instead of a password.
108
108
EMC® Cloud Tiering Appliance Getting Started Guide
•
The server and client can negotiate an encryption scheme to secure all traffic
between them.
Once authentication is established and an encryption scheme is optionally selected,
the LDAP client requests user authentication.
Configuring LDAP settings
To start LDAP configuration:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security.
Select Configure LDAP.
Select Enable LDAP.
Configure the basic LDAP settings:
a.
Maximum time the LDAP client waits for an initial response from the
server
Type a period of time. The client retries after waiting for 2 seconds and
thereafter continues retrying after doubling the wait time from the previous
retry attempt. The client continues to retry until either the server responds or
the configured LDAP search time limit is exceeded. The default time limit is 10
seconds.
b.
LDAP bind policy
Select soft or hard. The default setting is hard, which indicates that the client
will retry bind connections to the LDAP server.
c.
Maximum time for which the LDAP client waits for a bind response from
the server
Type a period of time. If the bind policy is set to soft, this setting has no
effect. If the bind policy is set to hard, this policy causes a bind retry
mechanism to occur.
d.
LDAP server type
Select from the supported server types:
−
OpenLDAP — Applies to LDAP servers distributed by OpenLDAP.
−
Active Directory with RFC2307 support
Note: If you do not have a Unix Attribute tab in the AD settings, you must
install Identify management for Unix, which is available from
Microsoft. This generates the Unix Attribute tab.
Other LDAP servers have not been validated for CTA version 7.2 or later.
e.
IP address or hostname for the LDAP server
If using Open LDAP, for which certificate-based authentication is enabled,
type the hostname that matches the hostname used in the certificate
generation. If an IP address was used in the certificate generation instead of
the hostname, type the IP address.
EMC® Cloud Tiering Appliance Getting Started Guide
109
109
Note
f.
Failure to type the proper information will create problems during the
LDAP setup. This is one of the most common configuration errors
during LDAP setup.
LDAP basedn
Type the suffix for your domain name.
g.
LDAP binddn
Specify the LDAP binddn for the Active Directory.
h.
LDAP bindpw
Password for the specified binddn. This is specific to AD configuration.
i.
LDAP CA Certificate Path
Path to the Certificate Authority certificate stored on the CTA.
j.
LDAP-enabled SASL
To configure SASL, provide the following information:
Note
−
SASL KDC address
−
Domain name
−
Kerberos principal details
−
Kerberos keytab file
−
Name server IP address
With LDAP enabled, CTA users can log into the CLI.
To log into the GUI:
•
The single security database (SSD) setting must be enabled on the CTA.
•
Users allowed to log in to the CTA must be added to the rainfinity and wheel
groups in the LDAP server database.
If the GUI is running and LDAP is enabled through rfhsetup, the GUI will not recognize
LDAP authentication attempts until it is restarted by typing the following command:
/opt/rainfinity/filemanagement/bin/fmgui restart
To avoid this problem:
Enable external authentication (LDAP) before enabling the single security
database.
Invoke the GUI.
Note
110
110
If changing the CTA IP address or moving the CTA to a new location, disable
remote login and re-enable root login before changing or moving the CTA.
After changing or moving the CTA, re-enable LDAP with the IP address or
hostname of a LDAP server that is reachable in the new configuration.
EMC® Cloud Tiering Appliance Getting Started Guide
Certificate management
When configuring LDAP, TLS, and SSL for authentication, key and certificate files are
required. In order for authentication encryption to work correctly, these keys and
certificates must be:
•
Periodically refreshed
•
Correctly located on the appliance
Each certificate has an expiration date. Every week, the CTA checks the validity of
each certificate. Certificate warning information is logged into the /var/log/secure
file, and if the alert is enabled, email is sent when the certificate is due to expire.
Once a certificate expiration warning is received, SSL/TLS certificates must be
updated.
To update and manage the keys and certificates:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure System Security.
Select Certificate Management.
To update either the Certificate Authority (CA) public certificate or the Client key
and certificate for use with SSL/TLS:
a.
Select Update Certificate.
b.
Type Y.
c.
Type the scp path from which the selected certificate or key file will be
copied to the CTA.
Appliance mail delivery settings
The CTA supports delivery of alerts through email. To send these alerts, sendmail
must be properly configured. A menu is provided within the rfhsetup tool. To use this
menu:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure CTA Mail Delivery Settings. The Appliance Mail Configuration
menu appears.
Follow the prompts to configure:
a.
Change Configuration — When prompted, type y.
b.
Sender’s email address — Type the address that will appear in the From
field of the alert emails sent by the CTA. For example,
johndoe@acme.com.
c.
SMTP server — Type the server to which mail should be sent. For
example, mailhub.eng.acme.com.
d.
email verification — Type a recipient email address to which test emails
may be sent. For example, adminjoe@acme.org. The rfhsetup script will
attempt to verify the mail configuration by sending two emails.
EMC® Cloud Tiering Appliance Getting Started Guide
111
111
Wait a few minutes. Check the email account to see if these emails were
successfully received.
Mail Test 1 — To confirm the receipt of an email with the subject Mail Test 1, type
y. Otherwise, type n.
Mail Test 2 — To confirm the receipt of an email with the subject Mail Test 2, type
y. Otherwise, type n.
If either of the test emails was received, mail delivery is working and mail setup is
done.
If neither test email was received, verify:
•
The name of the SMTP server. Check with your system administrator.
•
The email address provided for the test email.
•
The SMTP server is reachable. Try to ping it.
Log settings
When the security level is set to harden, any event that might affect the security of the
system is written to the CTA log files. Use the Cloud Tiering Appliance setup tool to
administer and preserve log files.
Configuring log rotation
With log rotation, the user controls the periodic rotation of files.
To configure log rotation:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure Logging Options.
Select Configure Log Rotation.
Follow the prompts to configure:
a.
Log rotation frequency — Daily, weekly, or monthly
b.
Rotation mode — Size or time
c.
Max log size (for non-debug files)
d.
Max debug log size
e.
Number of copies to keep for each log file
Configuring SCP of rotated log files
Log rotation is the first step in archiving the CTA system logs. These log files are
eventually deleted as a part of the normal rotation process. However, in many
customer environments, it may be necessary to preserve these files by copying them
to a remote server. Use the CTA to create a tar file of these rotated system and the CTA
logs, then secure copy them to a remote server.
112
112
EMC® Cloud Tiering Appliance Getting Started Guide
Configuring the public-private key exchange
Prior to configuring secure copy (SCP) of rotated log files, a public-private key
exchange must take place.
To configure the public-private key exchange:
Log in to the CTA or CTA-HA as root.
Generate the public key by typing ssh-keygen -t rsa.
a.
When prompted, press Enter to accept default answers for:
b.
File in which to save the key, for example, type: /root/.ssh/id_rsa
c.
No passphrase
d.
Confirm no passphrase
e.
At the end of the configuration, a message appears acknowledging:
f.
Your identification is saved in /root/.ssh/id_rsa.
g.
Your public key is saved in /root/.ssh/id_rsa.pub.
For the external server where the log files will be placed, create a user with write
access to the copy directory. Do not use the root user.
Note
In the following steps, server is the IP address or hostname of the external
server, and user is the name of the user on the external server which will
copy the files.
Log in to the CTA or CTA-HA and use SSH to:
Create the directory ~/.ssh by typing the command:
ssh <user>@<server> mkdir -p .ssh
a.
Type the user password.
b.
Append the public key on the CTA or CTA-HA by typing the command:
cat /root/.ssh/id_rsa.pub | ssh <user>@<server> 'cat >>
.ssh/authorized_keys'
c.
Type the user password.
d.
Set correct permissions by typing the command:
ssh <user>@<server> chmod -R 700 .ssh
e.
Type the user password.
To verify successful completion, attempt to log in to the external server as user
from the root account on the CTA by typing:
ssh <user>@<server>
You should not be prompted for a password.
You can now successfully use SCP without a password to send the rotated log files to
your external server.
EMC® Cloud Tiering Appliance Getting Started Guide
113
113
Configuring SCP of rotated log files by using rfhsetup
Once the public-private key exchange is completed, configure scp of rotated log files:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure Logging Options.
Select Configure SCP of Rotated Log Files.
Follow the prompts to configure:
a.
The SCP Remote Address — The IP address or hostname of the external
server. This is the external server referenced in Configuring the publicprivate key exchange.
b.
The username to whose account the log files will be copied — The name
of the user on the external server who will copy the files. Same as the
user provided in Configuring the public-private key exchange.
c.
The full path to the directory at the remote site where the log files should
be placed. The user must have write access to this directory.
Following the configuration, the CTA will test SCP by attempting to copy a test file. If
this test fails, the SCP settings will be accepted, but SCP is probably not configured
properly. Correct the error that is blocking SCP and rerun the Cloud Tiering Appliance
setup tool.
Configuring alerts
A CTA can be configured to monitor various system log files and send email to alert
whenever an event occurs. CTA sends notifications for SNMP traps and alerts listed in
Appendix B, Alerts.
Configuring email alerts
Use the GUI to review and configure the list of email alerts:
Click the Alert Settings link on the Configuration tab.
Click the Edit log alert Pattern link.
A list of alerts with the various alert settings appears:
a.
Alerts may be individually enabled.
b.
If alerts occur more than once within a specified time period, edit the
throttle time to suppress the repeated alerts. A different throttle time
may be applied to each alert.
Only admin users can view this configuration page.
To configure email alerts from the command line:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure Logging Options.
Select Configure Log Alerts.
Follow the prompts to configure:
114
114
EMC® Cloud Tiering Appliance Getting Started Guide
a.
When asked to enable alerts, type y.
b.
Specify one or more email addresses separated by a space or comma, to
receive the alerts.
Configuring SNMP alerts
Use the GUI to configure SNMP alerts:
Click the SNMP Configuration link on the Configuration tab.
On the SNMP Settings page that appears, add a notification host. This is the host
to which alerts will be sent:
a.
IP address
b.
UDP port (typically SNMP uses UDP port 161 for general SNMP messages
and UDP port 162 for SNMP trap messages)
c.
Community string
d.
Security type
Click Commit.
Click the Alert Settings link on the Configuration tab.
Under Alerts, click Enable SNMP alerts.
Only admin users can view this configuration page.
To configure SNMP alerts from the command line:
Configure the SNMP Notification Host:
a.
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
b.
Select Configure Logging Options.
c.
Select Configure SNMP.
d.
Select Configuration SNMP Notification Hosts.
e.
Add the SNMP Notification Hosts:
−
The number of hosts that may be added is unlimited.
−
For each host, specify: IPv4 address, UDP port number, SNMP
community string, and SNMP version.
−
The community string must be alphanumeric, and may include dashes
and underscores.
Enable SNMP alert generation:
a.
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
b.
Select Configure Logging Options.
c.
Select Configure Log Alerts.
d.
Follow the prompts to configure:
−
When asked to enable alerts, select Yes.
EMC® Cloud Tiering Appliance Getting Started Guide
115
115
−
Specify the type of alert delivery. Select either email only, SNMP only,
or email and SNMP.
Enabling SNMP polling
Use the GUI to enable SNMP polling:
Click the SNMP Configuration link on the Configuration tab.
On the SNMP Settings page that appears:
a.
Type a community string.
b.
Select a security type.
c.
Click Add. The community string is added to the Current Community
String list.
Click Commit.
To enable SNMP polling from the command line, configure the SNMP Community
String to be used for polling:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure Logging Options.
Select Configure SNMP.
Select Configuration SNMP Community Strings.
Add the SNMP Community Strings.
Note
a.
The number of strings that may be added is unlimited.
b.
For each string, specify the SNMP community string and SNMP version.
c.
The community string must be alphanumeric, and may include dashes
and underscores.
To poll for SNMP objects without enabling rfalertd, execute the command:
service rfsnmp start from the root account. This restarts SNMP and no alert
history is viewable until the alert daemon is restarted.
System command accounting
The CTA provides the ability to track any command that is successfully executed and
launches a new process.
To track command history, the CTA uses the psacct Process Accounting package. This
package tracks commands that are entered. In addition to commands, the CTA
extends this package to track command arguments.
To enable System Command Accounting on the CTA:
Start the Cloud Tiering Appliance setup tool, type rfhsetup.
Select Configure Logging Options.
Select Configure System Command Accounting.
Type y to enable system command accounting.
116
116
EMC® Cloud Tiering Appliance Getting Started Guide
Tracking user command history
After enabling System Command Accounting, admin users can track the list of
commands entered on the system with the tool: /opt/rainfinity/bin/rflastcomm.
To use this tool, admin users must be a superuser.
Examples of its use are as follows:
•
To list the commands entered by all users, use the tool without any options,
or:
/opt/rainfinity/bin/rflastcomm
•
To list the commands entered by a specific user, type:
/opt/rainfinity/bin/rflastcomm –u <username>
•
To list commands entered by a user since a start date on 5 p.m. on June 6,
2007, use the tool with the following arguments:
/opt/rainfinity/bin/rflastcomm –u <username> –s ‘2007-06-06
17:00:00’
•
To track system/daemon/session history, type:
/opt/rainfinity/bin/rfquerycshis.sh
•
For a help menu and additional options, type:
/opt/rainfinity/bin/rflastcomm --help
Tracking user login history
After enabling System Command Accounting, admin users can track the login history
with the tool /usr/bin/last.
To run this tool, admin users must su as root first.
This tool is part of the standard psacct Process Accounting package. For detailed info
on using this tool, type: man last.
Tracking daemon command history
To query daemon command history, such as xmlrpc commands issued to the daemon
from the GUI or through various CTA CLI commands, use the tool:
/opt/rainfinity/bin/rfquerycshis.sh.
•
To obtain the daemon command history, type:
/opt/rainfinity/bin/rfquerycshis.sh -t dc
•
To query the system command history, type:
/opt/rainfinity/bin/rfquerycshis.sh -t sc
•
To query the user login history, type:
/opt/rainfinity/bin/rfquerycshis.sh -t ls
•
To list hardware related messages from the system log files, type:
EMC® Cloud Tiering Appliance Getting Started Guide
117
117
/opt/rainfinity/bin/rfquerycshis.sh -t hw
Windows domain user
When a new file server is added to the CTA configuration, CIFS specific settings
include the username and password for the Windows domain user to be used by the
CTA. Before adding a new CIFS file server, use the instructions in the following
sections to set up the Windows domain user:
•
Creating a Windows domain user
•
Adding an admin user to the local administrator group
In addition, for CIFS authentication configure either:
•
Fully Qualified Domain settings — For Kerberos support as described in
Configuring Windows for Kerberos.
•
Domain controller Group Policy Object (GPO) — For NT LAN Manager (NTLM)
support as described in Configuring Windows 2008 for NTLM.
Note
CIFS specific settings are applicable for all servers except Centera, Atmos,
and Amazon S3.
Creating a Windows domain user
To create an administrator in the Windows 2000, 2003, or 2008 domain:
Log in to the primary domain controller as the Domain Administrator.
From the Start menu, select Start > Programs > Administrative Tools > Active
Directory Users and Computers.
Right-click Users.
Select New > User. The New Object — User dialog box appears:
a.
In the Full name box, type CTA Administrator.
b.
In the Login name box, type fmadmin.
The fmadmin login is the CTA Administrator Windows Domain user.
c.
Type a password.
This password is the fmadmin Windows password.
d.
(Optional) Select Password Never Expires.
Click Finish.
Note
If you have NetApp filers but no Windows 2000, 2003, or 2008 servers in your
domain, then you must include fmadmin in the domain administrator group.
Otherwise you will not be able to include the fmadmin user in the NetApp
filers’ administrators group.
Adding an admin user to the local administrator group
The fmadmin account must be added to the administrators group on the CIFS file
servers that will be involved in CTA archiving. To add a CTA Windows domain user on
a NetApp filer or a VNX Data Mover:
118
118
EMC® Cloud Tiering Appliance Getting Started Guide
Log in to the primary domain controller as the Domain Administrator.
From the Start menu, select Start > Programs > Administrative Tools > Computer
Management. The MMC application appears.
To start a Computer Management session with the file server:
a.
From the Action menu, select Connect to another computer. The Select
Computer dialog box appears.
b.
Click Browse or type the file server name to select the NetApp, VNX, or
Unity system to connect to.
c.
Click OK.
To include the fmadmin user in the administrator group for the CIFS file server:
a.
Under System Tools, in the folder Local Users and Groups, select Groups.
b.
Select Administrators. The Administrators Properties dialog box appears.
c.
Click Add. The Select Users or Groups dialog box appears.
−
Click Locations. From the Locations menu, select the domain instead
of the local computer.
−
Under Enter the object names to select, type fmadmin to add the
domain user.
d.
Click OK. The Administrator’s Properties dialog box reappears with the
newly added fmadmin user.
e.
Click OK.
Repeat this process for any other file servers that will be involved in CTA archiving.
Configuring Windows for Kerberos
By default, the Windows domain controller supports Kerberos authentication. Before
configuring a file server for CIFS authentication with Kerberos, configure the Fully
Qualified Domain Settings on the CTA:
Log in to the CTA GUI.
Select Configuration and Fully Qualified Domain.
CTA displays the Fully Qualified Domain List.
Click Add to add a new Fully Qualified Domain.
CTA displays a Fully Qualified Domain Properties dialog box.
Enter the Domain Name and IP Address of the Domain Controller.
Click Commit.
Configuring Windows 2008 for NTLM
If using NTLM for CIFS authentication instead of Kerberos, confirm that the domain
controller is configured for NTLM:
Log in to the Windows 2008 domain controller as the Domain Administrator.
From the Start menu, select Run. In the Run dialogue box that appears, type
gpmc.msc and click OK. The Group Policy Management dialog box appears.
EMC® Cloud Tiering Appliance Getting Started Guide
119
119
Expand the domain. Under Group Policy Objects, right-click Default Domain Policy
and select Edit. The Group Policy Management Editor appears.
Under Computer Configuration, select Policies > Window Settings > Security
Settings > Local Policies > Security Options.
In the list of policies, scroll down to Network security: LAN Manager
Authentication. Confirm that the policy setting shows that NTLM is configured for
authentication.
Close the Group Policy Management Editor.
SID translator
The CTA is able to translate Security IDs (SID) in the security properties of the files
and directories involved in a CIFS file migration task. The capability may be used to
assist projects in which the data’s group or user association changes from the source
to the destination. For example, when the Access Control List (ACL) is defined in
terms of local groups on the source file server.
When the data is migrated to the destination server, the ACL should be defined in
terms of corresponding local groups. The rules governing this translation are defined
in the SID translation files.
Installing the SID translator
The SID translator is packaged as a Microsoft Installer package, known as an MSI file.
The SID translator supports systems running Windows XP Professional (SP1 or later)
and Windows 2003 Server Standard and Enterprise editions.
.NET Framework 4 must be installed on the Windows server before installing the SID
translator utilities. The latest .NET Framework may be downloaded from Microsoft at:
http://msdn.microsoft.com/en-us/netframework/default.aspx
To install the SID translator:
Verify that your client has the .NET Framework 4 installed.
Go to the EMC Online Support web site:
http://Support.EMC.com
To download the SID translator utilities, select Downloads. Search for Cloud
Tiering Appliance. Download SIDUtilities<BuildNumber>.msi, where
<BuildNumber> is a number similar to 8_0b15.
To start the installation script, run the following file:
SIDUtilities<BuildNumber>.msi
120
120
EMC® Cloud Tiering Appliance Getting Started Guide
Creating the SID translation file
Use the SID translator to create a SID translation file.
Once the utility is installed, the SID translator screen appears:
Click Select for The groups and users to migrate under Source. The Select Groups
to Migrate dialog box appears:
a.
In the Source name box, type the name and click Query. The list of local
groups on that source appears.
b.
Select the local groups to migrate. Select only the local groups that are
unique to your source. For example, you would not select the
Administrators group that also likely exists on other file servers.
c.
Click Select.
The SID Translator dialog box reappears with The Groups to Migrate listed.
Click Select for The container to hold all of the migrated groups under
Destination. The Select Container for Migrated Groups dialog box appears:
a.
In the Destination name box, type a name and click Query. The list of
local groups on that destination appears.
b.
Select the destination for the source and click Select.
The SID Translator dialog box reappears with the names for the Source and the
Destination listed.
Click Configure for Map File Output under Options. The Map File Output dialog
box appears:
a.
Type the filename or click Browse to select an existing XML file.
b.
Click OK.
The SID Translator dialog box reappears with the name of the Map File Output
listed.
Click Test Run to test the validity of the setup by creating and removing groups on
the destination.
Click Migrate to create the SID translation file.
Uploading the SID translation file
To upload the SID translation file:
Select Configuration and File Migration Settings. The File Migration Settings page
appears.
To add a SID translation file:
a.
Click Add.
b.
Navigate to find the XML file and choose that file. When the file is
selected, it is added to the list.
EMC® Cloud Tiering Appliance Getting Started Guide
121
121
Network topology scenarios
Deleting a SID translation file
To delete a SID translation file:
Select Configuration and File Migration Settings. The File Migration Settings page
appears with a list of previously uploaded SID translation files.
Select the file to delete and click Delete.
122
122
EMC® Cloud Tiering Appliance Getting Started Guide
Network topology scenarios
Appendix A
Network
topology
scenarios
This appendix presents the following topics:
Advanced network topologies .................................................................. 124
VLAN tagging modes for the CTA/VE ......................................................... 127
EMC® Cloud Tiering Appliance Getting Started Guide
123
123
Network topology scenarios
Advanced network topologies
For many environments, using a single networking interface will satisfy networking
requirements.
However, there are cases when more complex topologies are needed.
•
Combining ethernet interfaces to form a bonded interface. This topology is
used for high availability, to protect the CTA installation from a single point of
failure.
•
Configuring the CTA with bonding provides details on how to set up this
network topology.
•
Using two subnets, one for the NAS primary storage tier, and another for
either the NAS/CAS secondary tier or for a management interface.
•
Configuring the CTA with two subnets provides details on how to set up this
network topology.
•
Using more than two subnets, for example, when there are three teams using
a CTA distributed across three different subnets.
•
Configuring the CTA with more than two subnets provides details on how to
set up this network topology.
Configuring the CTA with bonding
This configuration applies to the CTA installation and is commonly used when fault
tolerance must be built into the networking layer. In this example, eth0+eth1 are
combined into a bonded interface that is configured with the balance-rr bonding
mode:
Start the network configuration menu:
a.
Type rfhsetup from the CTA command prompt to invoke the system setup
menu.
b.
Select Configure Cloud Tiering Appliance Networking. The network
configuration menu appears.
c.
Select Configure Networking.
Add new bond interface:
a.
Type A to add an interface. Use the right arrow key to highlight Bond, and
press Enter.
b.
When prompted for a name of the new bond, use the up arrow key to
autogenerate a name. The name generated is bond1. Press Enter to
complete.
Edit new bond setting:
a.
Use the up and down arrow keys to select the bond1 interface. Press
Enter to edit the configuration.
b.
Specify a value for each item:
−
124
124
For Slave, type eth0 eth1.
EMC® Cloud Tiering Appliance Getting Started Guide
Network topology scenarios
−
For Trunking Mode, select balance-rr.
Complete other values as needed.
c.
Note
Once the interface configuration is defined, press the left arrow key to
exit the current menu. When prompted, select Yes to keep the new
setting.
If a bond interface is active, do not edit the IP addresses of the any Slaves.
Remove the bond before editing Slave configurations.
Save new settings, exit, and restart network services:
Note
a.
Press the left arrow key to exit the main menu. When prompted, select
Yes to save the configuration.
b.
The setup utility will restart the CTA network services for the new
configuration and return to the network configuration menu.
This configuration does not apply to CTA/VE.
Configuring the CTA with two subnets
In this example, the CTA is configured for two subnets with two physical ports (eth0,
eth1):
Start the network configuration menu:
a.
Type rfhsetup from the CTA command prompt to invoke the system setup
menu.
b.
Select Configure Cloud Tiering Appliance Networking. The network
configuration menu appears.
c.
Select Configure Networking.
Edit settings for the physical ports eth0 and eth1:
a.
Use the up and down arrow keys to select eth0 and press Enter. The
configuration menu for the eth0 interface appears.
b.
Provide information for each item to properly configure the interface.
c.
−
Press Enter to edit an item, the press Enter again to complete.
−
Press the left arrow key to exit the menu.
−
Select Yes to keep new settings.
Repeat these steps for the eth1 interface.
Save new settings, exit, and restart network services:
a.
Press the left arrow key to exit the main menu. When prompted, select
Yes to save the configuration.
b.
The setup utility will restart the CTA network services according to the
new configuration and return to the network configuration setup menu.
EMC® Cloud Tiering Appliance Getting Started Guide
125
125
Network topology scenarios
Configuring the CTA with more than two subnets
In this example, the CTA is configured for more than two subnets with two physical
interfaces. This configuration utilizes VLAN tagging and the switch connected to the
CTA ethernet ports must be properly configured for tagging. In Cisco terminology, the
switchport mode is set to trunk, and the required VLANs are allowed on the ports:
Start the network configuration menu:
a.
Type rfhsetup from the CTA command prompt to invoke the system setup
menu.
b.
Select Configure Cloud Tiering Appliance Networking. The network
configuration menu appears.
c.
Select Configure Networking.
Add new bond interface:
a.
Type A to add an interface. Use the right arrow key to select Bond, and
press Enter.
b.
When prompted for the name of the new interface, press the up arrow
key to generate a name. The name generated is bond1. Press Enter to
complete.
Edit the bond configuration:
Note
a.
Use the up and down arrow keys to select the new bond interface. Press
Enter. The configuration menu for the interface appears.
b.
For Slave, type eth0 eth1. Complete other values as needed.
c.
Once the interface configuration is defined, press the left arrow key to
exit the current menu. When prompted, select Yes to keep the new
setting.
Configuration settings are saved, but are not implemented until the Cloud
Tiering Appliance Network Setup menu is exited.
Add new VLAN interfaces:
a.
Type A to add an interface. Use the right arrow key to select VLAN, and
press Enter.
b.
Type a name for the VLAN bond interface. The naming convention is
<interface>.<vlan-ID>. For example, eth0.5 is a VLAN interface on eth0 with
a VLAN ID of 5
c.
Repeat these steps to create two more VLAN bond interfaces.
Edit the VLAN configuration:
126
126
a.
Use the up and down arrow keys to select the new VLAN interface. Press
Enter. The configuration menu for the interface appears.
b.
Provide information for each item to properly configure the interface:
−
Press Enter to edit an item, and then press Enter again to complete.
−
Press the left arrow key to exit the menu.
−
Select Yes to keep the new settings.
EMC® Cloud Tiering Appliance Getting Started Guide
Network topology scenarios
c.
Note
Repeat these steps for each new VLAN interface.
To delete a bond that is part of a VLAN bond interface, delete the VLAN
bond interface before deleting the bond.
Save the new settings, exit, and restart network services:
a.
Press the left arrow key to exit the main menu. When prompted, select
Yes to save the configuration.
b.
The setup utility will restart the CTA network services for the new
configuration and return to the network configuration menu.
VLAN tagging modes for the CTA/VE
The CTA/VE supports two VLAN tagging modes:
•
ESX Server virtual switch tagging
•
ESX Server virtual guest tagging
ESX Server virtual switch tagging
In the Virtual Switch Tagging (VST) mode, a VLAN ID is assigned to an ESX Server
switch port. Untagged layer 2 traffic is sent by using the link between the switch port
and the CTA/VE interface. When the switch receives this traffic, it directs it to the
configured VLAN.
On the CTA/VE, configure each physical eth1, eth2, eth3 or eth4 port with an IP
address, Net Mask, and Default Gateway.
Note
When using the VST mode, do not create a VLAN interface.
Configuring the VLAN number on the ESX switchport in VST mode
Virtual switch tagging is enabled when the port group’s VLAN ID is set to any number
between 1 and 4094, inclusive.
To use VST, create appropriate port groups. Give each port group a label and a VLAN
ID. Port group values must be unique on a virtual switch. Once the port group is
created, you can use the port group label in the virtual machine configuration.
To configure port group properties:
Log in to the VMware VI Client and select the server from the inventory panel.
The hardware configuration page for this server appears.
On the Configuration tab, click Networking.
Click Properties for a network.
The vSwitch Properties dialog box appears.
On the Ports tab, select the port group and click Edit.
In the Properties dialog box for the port group, click the General tab to edit:
a.
Network Label — This is the name of the port group that you are creating.
EMC® Cloud Tiering Appliance Getting Started Guide
127
127
Network topology scenarios
b.
VLAN ID — This identifies the VLAN that the port group’s network traffic
will use.
Click OK to exit the vSwitch Properties dialog box.
ESX Server virtual guest tagging
In the virtual guest tagging (VGT) mode, the link between the ESX Server switch port
and the CTA/VE ethernet port is permitted to carry traffic for multiple VLANs. This is
achieved by adding a VLAN ID or tag to each layer 2 frame transmitted between the
switch port and the CTA/VE ethernet port.
In Cisco parlance, this link is a trunk link.
The advantage of this link is that during VMware VMotion, the remote ESX Server recreates the trunk port, and the administrator does not need to preconfigure the
VLANs on the destination ESX Server/Switch combination. The use of VGT prevents
errors during VMotion.
Configuring VGT on the ESX Server
To configure VGT:
Log in to the VMware VI Client, and select the server from the inventory panel. The
hardware configuration page for this server appears.
On the Configuration tab, click Networking.
Click Properties for a network.
The vSwitch Properties dialog box appears.
On the Ports tab, select the port group and click Edit.
In the Properties dialog box for the port group, click the General tab to edit:
a.
Network Label — This is the name of the port group that you are creating.
b.
VLAN ID — This identifies the VLAN that the port group’s network traffic
will use.
c.
To use VGT, type 4095.
Click OK to exit the vSwitch Properties dialog box.
Configuring VLAN interfaces on the CTA/VE
On the CTA/VE side, the VGT mode requires the creation of VLAN interfaces on top of
the CTA/VE ethernet interface. IP addresses are assigned only to the VLAN interfaces.
The VLAN bond interface is unconfigured and does not have an IP address. Use the
rfhsetup networking menu to configure the ethernet interface.
To add a VLAN interface on the CTA/VE:
Log in to the CTA/VE. The rfhsetup configuration menu appears.
Select Configure FileManagement networking. The Network configuration menu
appears.
Select Configure Networking. A list of interfaces appears:
FileManagement Network Setup,
128
128
EMC® Cloud Tiering Appliance Getting Started Guide
Main Menu
Network topology scenarios
Name
eth0
eth1
eth2
eth3
IP Address
Network Mask
Up/Down
DOWN
DOWN
DOWN
DOWN
Comment
Unconfigured
Unconfigured
Unconfigured
Unconfigured
1 of 4 entries displayed
Command: [Q]uit [A]dd [R]emove [S]ave [U]p [D]own re[F]resh
[H]elp Status: OK
rfhsetup <- Network configuration -> Interface eth0's
configuration
Type A to add a new interface. Use the left and right arrow keys to select a VLAN
interface and press Enter.
Type a name for the VLAN interface. The naming convention is <bond>.<vlan-ID>.
For example, to add VLAN ID 20 on eth0, the name will be eth0.20. After typing
the name, press Enter.
Note
The new VLAN bond interface (for example, eth0.20) will be added to the
interface list.
Use the up and down arrow keys to select the newly created VLAN interface. Press
the right arrow key. The eth0.20 VLAN configuration screen appears. Add the IP
address, netmask, and gateway.
Use the left arrow key to exit the eth0.20 configuration menu and save the
configuration.
Use the left arrow key to exit the Configure Networking menu and apply the saved
configuration.
EMC® Cloud Tiering Appliance Getting Started Guide
129
129
Alerts
Appendix B
Alerts
This appendix presents the following topics:
Supported SNMP traps............................................................................. 132
CTA alerts
........................................................................................... 133
EMC® Cloud Tiering Appliance Getting Started Guide
131
131
Alerts
Supported SNMP traps
Table 10 lists the SNMP traps for which the CTA will send a notification.
Table 10. Supported SNMP traps
132
132
Notification name
MIB where it is defined
SNMP OID
eRAAlertDaemonRestarted
EMC-RAINFINITY-ALERTSMIB
1.3.6.1.4.1.1139.9.3.2.0.1
eRAAlertsHistoryReset
EMC-RAINFINITY-ALERTSMIB
1.3.6.1.4.1.1139.9.3.2.0.2
eRARainfinityAlert
EMC-RAINFINITY-ALERTSMIB
1.3.6.1.4.1.1139.9.3.2.0.4
eRAGenericAlert
EMC-RAINFINITY-ALERTSMIB
1.3.6.1.4.1.1139.9.3.2.0.5
eRASecurityAlert
EMC-RAINFINITY-ALERTSMIB
1.3.6.1.4.1.1139.9.3.2.0.3
eRHSTemperatureAlert
EMC-RAINFINITYHARDWARE-STATUS-MIB
1.3.6.1.4.1.1139.9.3.1.0.1
eRHSFanAlert
EMC-RAINFINITYHARDWARE-STATUS-MIB
1.3.6.1.4.1.1139.9.3.1.0.2
eRHSPowerSupplyAlert
EMC-RAINFINITYHARDWARE-STATUS-MIB
1.3.6.1.4.1.1139.9.3.1.0.3
eRHSMemoryAlert
EMC-RAINFINITYHARDWARE-STATUS-MIB
1.3.6.1.4.1.1139.9.3.1.0.4
eRHSDiskAlert
EMC-RAINFINITYHARDWARE-STATUS-MIB
1.3.6.1.4.1.1139.9.3.1.0.5
eRHSNICAlert
EMC-RAINFINITYHARDWARE-STATUS-MIB
1.3.6.1.4.1.1139.9.3.1.0.6
EMC® Cloud Tiering Appliance Getting Started Guide
Alerts
CTA alerts
The CTA alerts are classified by type:
•
Rainfinity alerts
•
Generic alerts
•
Security alerts
•
Hardware alerts
Table 11 lists all the CTA alerts.
Table 11. CTA alerts
Index
Pattern name
Description
Type
SNMP OID
001-0001
(sshd|telnetd).*se
ssion opened
User logged into this
system via ssh or
telnet.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0002
(sshd|telnetd).*se
ssion closed
An ssh or telnet user
logged out.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0003
Permission
denied for illegal
user
User is not
authenticated and
was denied access to
the system.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0005
failed to bind to
LDAP server
Attempt to bind to the
LDAP server failed.
Possible causes
include a
misconfigured LDAP
server address or a
network connectivity
issue. Delays in
logging in or executing
commands may result
if the LDAP server is
unavailable.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0006
Log rotation
Log rotation settings
have been modified
via rfhsetup.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
001-0007
scp of system log
files
Attempt to securely
copy the system log
files has been made.
The alert indicates
whether the attempt
succeeded or failed.
genericAlert
1.3.6.1.4.1.1139.9.3.2.0.5
001-0008
scp of CTA log
files
Attempt to securely
copy CTA log files has
been made. The alert
indicates whether the
attempt succeeded or
failed.
genericAlert
1.3.6.1.4.1.1139.9.3.2.0.5
EMC® Cloud Tiering Appliance Getting Started Guide
133
133
Alerts
134
134
Index
Pattern name
Description
Type
SNMP OID
001-0009
Invalid user
User is not known and
was denied access to
the system.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0010
Accepted
keyboardinteractive
User is not known and
was denied access to
the system.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0011
Security level
System's security level
has been modified.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0013
Certificate Expire
Warning
One certificate will
expire soon or has
already expired.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0014
authentication
failure
User's login attempt
via ssh has failed due
to an invalid
password.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0015
changed
password expiry
User's password
expiry information is
changed. This
typically happens if
password aging is
enabled, modified or
disabled.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0016
password
changed
User’s password has
been changed in the
local user database.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0017
Log Alerts system
enabled
rfalertd has been
started.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-0018
Log Alerts system
disabled
rfalertd has been
terminated.
securityAlert
1.3.6.1.4.1.1139.9.3.2.0.3
001-3001
rfhsetup
User has launched the
rfhsetup tool.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
002-1001
Temperature Alert
Temperature status
has changed or a
temperature failure
has occurred.
hardwareAlert
1.3.6.1.4.1.1139.9.3.1.0.1
002-1002
Fan Alert
Fan status has
changed or a fan
failure has occurred.
hardwareAlert
1.3.6.1.4.1.1139.9.3.1.0.2
002-1003
Power Supply
Alert
Power supply status
has changed or a
power supply failure
has occurred.
hardwareAlert
1.3.6.1.4.1.1139.9.3.1.0.3
EMC® Cloud Tiering Appliance Getting Started Guide
Alerts
Index
Pattern name
Description
Type
SNMP OID
002-1004
Memory Hardware
Alert
Memory hardware
status has changed or
a memory hardware
failure has occurred.
hardwareAlert
1.3.6.1.4.1.1139.9.3.1.0.4
002-1005
Disk Alert
Disk hardware status
has changed or a disk
failure has occurred.
hardwareAlert
1.3.6.1.4.1.1139.9.3.1.0.5
002-1006
NIC Alert
Network card status
has changed or a
network card failure
has occurred.
hardwareAlert
1.3.6.1.4.1.1139.9.3.1.0.6
002-1007
capacity
utilization
Partition capacity
utilization exceeds a
pre-configured
threshold.
genericAlert
1.3.6.1.4.1.1139.9.3.2.0.5
002-3001
Problem starting
filemanagement
daemon
Problem starting
filemanagement
daemon
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
002-3002
filemanagement
daemon stopped
filemanagement
daemon has been
stopped
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
002-3003
filemanagement
daemon started
filemanagement
daemon has been
started
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
002-3004
The number of
CCD connection in
CLOSE_WAIT
The number of CCD
connection in
CLOSE_WAIT exceeds
threshold
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
003-0001
Partition is full
A partition is full.
genericAlert
1.3.6.1.4.1.1139.9.3.2.0.5
301-0001
filemanagement
daemon enabled
filemanagement
daemon has been
enabled.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
301-0002
filemanagement
daemon disabled
filemanagement
daemon has been
disabled.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
301-0003
CTA-HA unable to
contact Cloud
Tiering Appliance
CTA has not been
responsive for CTA-HA
(as FCD) after a
sufficiently long
period.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
EMC® Cloud Tiering Appliance Getting Started Guide
135
135
Alerts
136
136
Index
Pattern name
Description
Type
SNMP OID
301-0005
Automatic
creation of a
DHSM connection
rfwalker could not
automatically create a
DHSM connection.
Manually create it with
command fs_dhsm.
See the task
summaries for more
details.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
301-0006
Archived files
count limit
exceeded.
Archived files limit
has been exceeded.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
301-0007
Could not update
capacity values
CTA was unable to
update Capacity
values for the
specified filesystem.
This will affect
Capacity based
archiving on this
filesystem.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
301-0008
Database vacuum
is due to be
performed.
DB Data folder size
exceeds 2 times the
number of archived
files. Perform a
database vacuum.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
302-0001
CTA-HA unable to
contact Cloud
Tiering Appliance
CTA has not been
responsive for CTA-HA
(as CCD) after a
sufficiently long
period.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
302-0002
(Centera) had this
problem during
connect
Centera has not
responded to a
connection request.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
302-0003
The recall
username/passw
ord does not
seem to be in
sync across CTAs
and may cause
recall problems
CCD has been
monitoring multiple
CTAs and the recall
passwords on all the
CTAs are not the
same.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
302-0004
has been rejected
because a
Centera with
same name exists
for a different CTA
IP
Centera with same
name has been added
on multiple CTAs.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
EMC® Cloud Tiering Appliance Getting Started Guide
Alerts
Index
Pattern name
Description
Type
SNMP OID
302-0005
The digest
password or
digest username
is empty
Recall credentials are
empty. If using CCD
with mutiple CTAs,
ensure all the CTAs
have credentials
configured
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
303-0001
GUI user logged in
successfully
GUI user has logged in
successfully.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
303-0002
GUI login attempt
failed
GUI login attempt has
failed.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
303-0003
GUI user logged
out
GUI user has logged
out.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
304-0001
exceeds threshold
NAS Repository usage
has exceeded the
configured threshold.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
304-0002
Task failed too
many operations
and terminated
early
Task has failed too
many operations and
has been terminated
early.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
304-0003
Failure setting
retention for the
Atmos object
Failure to set retention
for the Atmos object.
Verify that the Atmos
policy specifies
retention.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
305-0001
StubScanner
progress
Display number of CFA
files converted by the
StubScanner
periodically. Only
displayed after CFA
Stubs are found.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
305-0002
StubScanner
Complete
Display final number
of CFA files converted
by the StubScanner.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
305-0003
DXConversion
progress
Display number of DX
NAS stub files
converted
periodically. Only
displayed while
DXConversion is
running.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
305-0004
DXConversion
Complete
Display final number
of DX NAS stub files
converted.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
EMC® Cloud Tiering Appliance Getting Started Guide
137
137
Alerts
138
138
Index
Pattern name
Description
Type
SNMP OID
306-0001
Task completed
Task has completed.
Additional details
provide task
information and
statistics.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0001
Unable to open
connection to
Centera
Either a invalid PEA
file has been specified
or connectivity to
Centera is down.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0002
Archive Warning
threshold reached
Warning when
Capacity Archive has
reached the
threshold.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0003
Archive by
Capacity started
Notice when Capacity
Archive has started.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0004
Tasks remaining
in the pending
queue will be
ignored
Alert when pending
queue is not empty
when FMD has been
shutdown.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0005
Failed to archive
backup file
Alert when copying of
backup file to backup
destination has failed.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0006
Failed to restore
backup file
Alert when restoring of
backup file from
backup destination
has failed.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0007
No successful
database
backups done for
the past
Alert when no backup
task has run
successfully for the
past X number of
days.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0008
Policy execution
caused a
repository to
exceed its
capacity limit
Alert when the
execution of a policy
has caused a
repository to exceed
its capacity limit.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0009
File archiving has
reached over 80%
Alert when archived
files count has
reached 80% of 500
million max file limit.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0010
A fatal error has
caused a CTA
process to
terminate
A fatal error has
caused a CTA process
to terminate. The log
lists specific error
messages.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
EMC® Cloud Tiering Appliance Getting Started Guide
Alerts
Index
Pattern name
Description
Type
SNMP OID
701-0013
A vacuum task
will start within
the next 1 hour.
Alert when a vacuum
task will start in the
next 1 hour
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
701-0014
File Migration task
reached its file
threshold limit
Recursive File
Migration task has
reached its file
threshold limit and
will not auto run
again. Correct the
situation and try
again.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
801-0001
Failed to recall file
from NetApp
A recall from NetApp
failed
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
901-0001
Found a duplicate
Atmos name and
so this
configuration will
not be pulled
down
Duplicate Atmos name
rejected by ACD.
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
901-0002
The recall
username/passw
ord does not
seem to be in
sync across CTAs
and may cause
recall problems
Password is not in
sync across multiple
CTAs configured for
this ACD
rainfinityAlert
1.3.6.1.4.1.1139.9.3.2.0.4
All alerts are listed in the Log Pattern Index of the GUI.
Use the CLI or the Alert Settings page in the CTA GUI to edit log alert patterns.
Configuration options include:
•
Status — Alerts can be individually enabled.
•
Throttle time — A different throttle time may be applied to each alert pattern.
If alerts occur more than once within a specified throttle time, the repeated
alerts are suppressed.
•
Included in summary — Included alerts appear in the alert summary.
Note
To enable e-mail alert messages from the device, alert settings must be
configured.
EMC® Cloud Tiering Appliance Getting Started Guide