mitsubishi heavy industries

mitsubishi heavy industries
MITSUBISHI
HEAVY
INDUSTRIES
Product Guide July 2016
01707 378 670 | ampair.co.uk
About Us
Mitsubishi Heavy Industries Product Guide
Contents
About Us......................................................02
Indoor - Ceiling Suspended..................146
Indoor - Floor Standing......................... 148
RAC Systems...............................................07
Range Overview.......................................08
Air Handling & HRV..................................153
Wall Mounted...........................................09
Outdoor Air Processing Unit................154
Floor Standing..........................................15
SAF-DX Fresh Air Assembly...................156
Compact Ducted.....................................16
SAF Heat Recovery Ventilation Units. 158
Multi Splits................................................17
KX EEV Valve Kits.....................................159
Multi Splits Combination Tables......... 25
PAC Heat Exchanger Interface............ 160
PAC Systems...............................................39
Q-ton.............................................................163
Range Overview.......................................40
The Q-ton Story.......................................164
Wall Mounted...........................................41
Why Q-ton?...............................................165
Compact Cassette...................................44
How it works.............................................166
4 Way Cassette........................................47
Specification.............................................168
Standard Ducted.....................................55
High Static Ducted..................................63
Air to Water................................................169
Ceiling Suspended..................................71
Air to Water Heat Pumps......................170
Floor Standing..........................................79
Twin, Triple & Quad Systems...............86
Controls....................................................... 173
VRF.................................................................91
AMP Diamonds..........................................183
Outdoor - Overview................................93
Outdoor - KX6 Heat Pump....................95
Reference/Faults...................................... 187
Outdoor - KXZ Heat Pump....................99
Outdoor - KXR6 Heat Recovery...........110
Index............................................................. 192
Outdoor - R22 Renew............................118
Indoor - PFD Boxes & Branch Pipes.. 120
Indoor - Overview...................................121
Indoor - Heating/Cooling Capacities..122
Indoor - Cassettes...................................124
Indoor - Ducted.......................................134
Indoor - Wall Mounted.......................... 144
Where are we?
AMP are located in Welwyn Garden City,
Hertfordshire only 20 miles from the M25 (Jct
23) and 3 miles from the A1(M) (Jct 6).
AMP Air Conditioning, Blenheim House
Blenheim Court, Brownfields
Welwyn Garden City
Herts, AL7 1AD
ampair.co.uk | 01707 378 670 | [email protected]
1
About Us
About Us
An Introduction to AMP
WE’VE WORKED HARD OVER THE YEARS TO
BUILD A COMPANY KNOWN AS INDUSTRY
LEADING. OUR CUSTOMERS ARE ALWAYS
OUR FIRST PRIORITY AND WE PRIDE
OURSELVES ON A LEVEL OF SERVICE AND
SUPPORT THAT’S UNPARALLELED.
Martin Michaelson
Company Director & Co-owner
AMP has grown since its inception in 1989 to become
one of the UK’s largest independent distributors of air
conditioning products. We’ve done this by ensuring we
consistently keep our customers at the centre of what we
do. We know how much you rely on us to provide you
with the right product at the right time so we work hard
to make sure we’re second-to-none when it comes to
customer service and support.
Over the past year we’ve developed our business to
give you the confidence that we’re the most qualified
partner for all your air conditioning needs. For
example, we recently secured two internationally
recognised accreditations for environmental and quality
management. Our ISO 9001 and 14001 accreditations
require us to follow clear, documented procedures for
managing our business to consistently achieve high
customer satisfaction.
Equally, we continue to invest in our staff through
professional training and qualifications to ensure
they can provide the high levels of sales and technical
support you’ve come to expect from AMP. Within the
last year, over 12 members of the AMP team have
completed NVQs in Management and Customer Service.
We are delighted and very proud of their achievements
with these qualifications.
@amp_aircon |
amp-air-conditioning
Moving forward we intend to continue improving AMP
for the benefit of our loyal customers. We will continue
to develop and improve our AMP Diamonds loyalty
programme hand-in-hand with Mitsubishi Heavy
Industries so it provides you with the unique benefits
your business requires. We are also launching a brand
new website providing you with up to date information
on not only the MHI products we sell but also industry
news, technical support and product resources.
Please do feedback anything we can do to help your
business be more successful. We look forward to
working with you over the coming months and years.
Polly McConachie
Company Director & Co-owner
2
About Us
About Us
Customer Services
Industry Leading Technical Support
We offer an experienced and dedicated pre and post sales technical support team
who have many years experience across all MHI product ranges. Their expertise
encompasses answering the smallest query right through to designing and
supporting complex VRF projects. We also have specialist engineers on call to help
commission and fault find at a moment’s notice.
Design Services
At AMP we understand that selecting the right equipment for your project is of
the utmost importance. With this in mind, our in-house design team is available
to provide help with the design of all aspects of your project, whether it’s for a
commercial or domestic environment. Our experienced team can review your
requirements and apply the most suitable equipment from our portfolio to meet
both your needs and budget.
Training
We believe in passing on knowledge and expertise to our customers. Our specially
designed MHI training courses cover product selection, installation, maintenance
and controls. We offer the opportunity of hands-on training giving your engineers
the opportunity to experience working systems. Certificates and training guides are
offered as part of each course for reference and proof of attendance.
Warranty & After Sales Support
All products supplied by AMP are provided with a comprehensive three year warranty
as standard, covering parts and a contribution towards fitting costs*. In the unlikely
event that you encounter a problem with an MHI system, you can rest assured it will
be resolved quickly and efficiently by our professional after sales team. Extended
warranties are offered through AMP Diamonds - see page 183 for more information.
Delivery
We pride ourselves on flexibility of service, offering next day delivery on all orders
received up to 3pm the day before. With our main warehouse in Hertfordshire
(just north of London) and benefiting from multiple warehouse storage facilities
throughout the UK, we are ideally placed to serve the capital and the rest of the UK
quickly and easily. For urgent orders, same day delivery may be available depending
on stock availability and delivery location.
Additional services offered by AMP include Grille Colour Matching, Coil Coating,
Bespoke Control Panels, VRF Strip-Down and On-site Engineer visits. Contact your
local sales representative or call our customer services team for more information.
*Terms & Conditions apply.
ampair.co.uk | 01707 378 670 | [email protected]
3
About Us
About Us
Customer Testimonials
CLIVE MARRIOTT
MELTON AIR CONDITIONING
“AMP continue to provide excellent service across
the board. Rapid turnaround on quotes, excellent
availability on stocks, competitive prices and
prompt reliable delivery service. Plus an unrivalled
after sales and technical back-up.”
MARK LEWIS
AIRWAY AIR CONDITIONING
“AMP really understand customer service. If
we need the impossible it is always AMP that
we turn to. Their service is second to none and
they will bend over backwards to meet our high
expectations. They care about the service they
deliver and this is no doubt why they constantly
deliver excellence.”
MATTHEW FRARY
ANGLIA AIR CONDITIONING
“In a crowded distribution network, we have
always valued AMP’s efficiency and reliability.
Their attention to detail is second to none which
enables them to stand head and shoulders above
their peers.”
“
MITSUBISHI HEAVY
INDUSTRIES HAVE
WORKED WITH AMP FOR
A NUMBER OF YEARS
NOW AND TOGETHER
WE HOLD A STRONG
PARTNERSHIP IN THE
UK MARKET. THEY
SHOW GREAT WORK
ETHOS & RELIABILITY
AND WE VERY MUCH
LOOK FORWARD
TO CONTINUING
OUR SUCCESSFUL
RELATIONSHIP WITH
AMP IN THE FUTURE.
”
Annemarie Schaal
Mitsubishi Heavy Industries Air Conditioning Europe
IAN ADAMS
ACE
“AMP have been one of our key supply partners for
a number of years now, and we truly value their
excellent customer service. They are an honest and
straight talking team of people, who are in tune
with our own company values and behaviours. It
is a pleasure to do business with them.”
@amp_aircon |
amp-air-conditioning
4
About Us
“Quick, efficient and professional
service is what we come to expect in our
dealings with AMP. They set the bar high
with their level of customer service and
have never disappointed.”
Gary Spooner - UIMS
Photo: Richard Bak, Internal Sales Manager at AMP
ampair.co.uk | 01707 378 670 | [email protected]
5
About Us
AMP Diamonds
The reward programme from Mitsubishi Heavy Industries
& AMP Air Conditioning.
Extended Warranties | Reward Vouchers | Marketing Cashback
See page 183 for more information
or visit ampdiamonds.co.uk
Terms & Conditions apply.
@amp_aircon |
amp-air-conditioning
6
RAC Systems
RAC Systems
ampair.co.uk | 01707 378 670 | [email protected]
7
RAC Systems
RAC Systems
Range Overview
MHI provide a wide range of residential air conditioning systems offering industry leading
functionality, including:
»» A wide range of unit styles and sizes,
including wall mounted, floor standing
and ducted
»» Infrared control with new weekly timer on
selected units
»» New silent mode reduces noise levels on
selected outdoor units
»» Advanced vector control technology
throughout the range providing high
energy efficiency
»» High filtration rates and self clean function
on selected models
»» Night setback operation ensures room
temperatures can be maintained even
when unoccupied. Available on majority of
systems
Nominal Cooling
2.0
Wall Mounted
Standard Inverter
SRK ZMP-S
2.5
3.5
4.5
09
09
09
5.0
6.3
7.1
8.0
11
12
Wall Mounted
Premium
Inverter
SRK ZM-S
10
10
10
11
11
Wall Mounted
Hyper Inverter
SRK ZMX-S
13
13
13
14
14
6.1kW
Floor Standing
Hyper Inverter
SRF ZMX-S
15
15
15
Compact Ducted
Hyper Inverter
SRR ZJ-S
16
16
Compact
Cassette Hyper
Inverter
FDTC VF
45
45
3.6kW
45
4.0kW
50
50
5.6kW
All units single phase | Multi Split systems also available - see page 17 for details | Page numbers shown in italics.
@amp_aircon |
amp-air-conditioning
8
RAC Systems
Wall Mounted Standard Inverter
Infrared Remote Controller
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
Included
SRK45ZMP-S
Included
SRC25ZMP-S
SRC35ZMP-S
SRC45ZMP-S
2.5 (0.9 - 2.8)
3.2 (0.9 - 3.5)
4.5 (0.9 - 4.8)
kW
UK Cooling (Total - Sensible)
kW
2.4 - 2.1
3.0 - 2.3
4.3 - 3.0
Nominal Heating (Range)
kW
2.8 (0.8 - 3.9)
3.6 (0.9 - 4.3)
5.0 (0.8 - 5.8)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Cooling
Heating
2.0
2.6
3.6
5.50 - 3.82
6.15 - 4.00
5.38 - 3.81
A/A
A++ / A+
A/A
3.21 - 3.71
3.22 - 3.62
3.01 - 3.61
A/A
B/A
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
SRK35ZMP-S
Included
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
46 to -15
°C
24 to -15
°C
Indoor Unit Dimensions (H-W-D)
mm
262 - 769 - 210
262 - 769 - 210
262 - 769 - 210
Outdoor Unit Dimensions (H-W-D)
mm
540 - 645 (+57) - 275
540 - 645 (+57) - 275
595 - 780 (+62) - 290
Weight (Indoor - Outdoor)
kg
6.9 - 25
7.2 - 27
7.6 - 40
Indoor Unit Airflow Rate Cool (L-M-H)
l/s
70 - 122 - 168
70 - 113 - 158
63 - 120 - 150
Indoor Unit Airflow Rate Heat (L-M-H)
l/s
87 - 122 - 158
92 - 123 - 160
103 - 153 - 200
Pa
0
0
0
Indoor Sound Pressure Cool (L-M-H)
dB(A)
23 - 34 - 45
23 - 36 - 47
25 - 40 - 46
Indoor Sound Pressure Heat (L-M-H)
dB(A)
26 - 34 - 43
28 - 36 - 44
32 - 43 - 48
Outdoor Sound Pressure (Cool-Heat)
dB(A)
47 - 45
49 - 48
52 - 53
Pipe Sizes (Gas - Liquid)
in
3/8" - 1/4"
3/8" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
15 - 10
15 - 10
25 - 15
Pre-charged for
m
10
15
15
Charge R410A (Factory - Additional)
kg
0.655 - 20g/m
0.81 - n/a
1.20 - 20g/m
Yes
Yes
Yes
Static Pressure
Suitable for Replacement Tech.
Indoor Drain Connection
mm
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
VP16 (14id 16od)
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
3.8 - 3.7
4.7 - 4.7
6.7 - 6.2
Interconnecting Cables
POWER
SRK25ZMP-S
kW
0.780 - 0.755
0.995 - 0.995
1.495 - 1.385
Start - Max Run Current
A
4.0 - 9.0
5.0 - 9.0
7.0 - 14.0
Suggested Fuse Size
A
13
13
16
£245
£302
£389
Power Consumption (Cool - Heat)
Indoor Unit
Outdoor Unit
£423
£468
£592
Retail Price
£668
£770
£981
Auto restart function | Gravity drain | Not compatible with SC-BIKN-E hard wired controller | No 7-day time clock.
ampair.co.uk | 01707 378 670 | [email protected]
9
RAC Systems
Indoor Unit
RAC Systems
Wall Mounted Premium Inverter
Infrared Remote Controller
PERFORMANCE
Outdoor Unit
EFFICIENCY
Included
SRK35ZM-S
Included
SRC20ZM-S
SRC25ZM-S
SRC35ZM-S
2.0 (1.0 - 2.7)
2.5 (1.0 - 2.9)
3.5 (1.0 - 3.8)
kW
kW
1.9 - 1.7
2.4 - 1.9
3.3 - 2.6
Nominal Heating (Range)
kW
2.7 (1.2 - 3.9)
3.2 (1.2 - 4.2)
4.0 (1.3 - 4.8)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
SRK25ZM-S
Included
UK Cooling (Total - Sensible)
1.9
2.3
2.9
7.00 - 4.05
7.10 - 4.16
7.10 - 4.17
A++ / A+
A++ / A+
A++ / A+
4.55 - 4.35
4.03 - 4.00
3.47 - 4.00
A/A
A/A
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
SRK20ZM-S
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Cooling
46 to -15
°C
Heating
21 to -15
°C
Indoor Unit Dimensions (H-W-D)
mm
294 - 798 - 229
294 - 798 - 229
294 - 798 - 229
Outdoor Unit Dimensions (H-W-D)
mm
540 - 780 (+62) - 290
540 - 780 (+62) - 290
540 - 780 (+62) - 290
Weight (Indoor - Outdoor)
kg
9.5 - 31.5
9.5 - 31.5
9.5 - 34.5
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
80 - 88 - 93 - 130
83 - 88 - 100 - 132
83 - 90 - 107 - 168
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
75 - 83 - 105 - 163
77 - 85 - 108 - 177
80 - 102 - 157 - 213
Pa
0
0
0
Indoor Sound Pressure Cool (UL-L-M-H)
dB(A)
21 - 24 - 27 - 33
21 - 24 - 28 - 34
22 - 26 - 32 - 42
Indoor Sound Pressure Heat (UL-L-M-H)
dB(A)
21 - 24 - 31 - 36
21 - 24 - 31 - 39
22 - 25 - 37 - 43
Outdoor Sound Pressure (Cool-Heat)
dB(A)
47 - 46
48 - 49
50 - 51
Pipe Sizes (Gas - Liquid)
in
3/8" - 1/4"
3/8" - 1/4"
3/8" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
15 - 10
15 - 10
15 - 10
Pre-charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
0.75 - n/a
0.75 - n/a
1.05 - n/a
Yes
Yes
Yes
Static Pressure
Suitable for Replacement Tech.
Indoor Drain Connection
mm
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
VP16 (14id 16od)
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
2.4 - 3.1
3.1 - 3.8
4.7 - 4.7
Interconnecting Cables
POWER
RAC Systems
Indoor Unit
kW
0.44 - 0.62
0.62 - 0.80
1.01 - 1.00
Start - Max Run Current
A
3.1 - 9.0
3.8 - 9.0
4.7 - 9.0
Suggested Fuse Size
A
13
13
13
£264
£292
£342
Power Consumption (Cool - Heat)
Indoor Unit
Outdoor Unit
£421
£489
£545
Retail Price
£685
£781
£887
New weekly timer function | Night setback | Outdoor silent operation mode | Optional hard wired controller with addition of SC-BIKN-E & RC-E5 | Gravity drain.
@amp_aircon |
amp-air-conditioning
10
RAC Systems
Wall Mounted Premium Inverter
Infrared Remote Controller
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
Included
SRK71ZR-S
Included
SRC50ZM-S
SRC63ZR-S
SRC71ZR-S
5.0 (1.6 - 5.5)
6.3 (1.2 - 7.1)
7.1 (2.3 - 7.7)
kW
UK Cooling (Total - Sensible)
kW
4.8 - 3.4
6.0 - 5.1
6.7 - 5.5
Nominal Heating (Range)
kW
5.8 (1.6 - 6.6)
7.1 (0.8 - 9.0)
8.0 (2.0 - 10.0)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Cooling
4.2
5.1
5.8
6.30 - 4.20
7.60 - 4.70
7.20 - 4.50
A++ / A+
A++ / A++
A++ / A+
3.23 - 3.65
3.41 - 4.08
3.46 - 3.88
A/A
A/A
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
SRK63ZR-S
Included
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
46 to -15
°C
°C
21 to -15
Indoor Unit Dimensions (H-W-D)
mm
294 - 798 - 229
339 - 1197 - 262
339 - 1197 - 262
Outdoor Unit Dimensions (H-W-D)
mm
640 - 800 (+71) - 290
640 - 800 (+71) - 290
750 - 880 (+88) - 340
Weight (Indoor - Outdoor)
kg
9.5 - 40.5
15.5 - 47.5
15.5 - 57.0
Indoor Unit Airflow Rate Cool (L-M-H)
l/s
88 - 100 - 130 - 188
173 - 262 - 302 - 342
173 - 270 - 310 - 342
Indoor Unit Airflow Rate Heat (L-M-H)
l/s
103 - 125 - 170 - 225
218 - 275 - 317 - 392
221 - 288 - 330 - 425
Static Pressure (Standard-Upper)
Pa
0
0
0
Indoor Sound Pressure Cool (L-M-H)
dB(A)
25 - 28 - 37 - 46
25 - 35 - 39 - 44
25 - 37 - 41 - 44
Indoor Sound Pressure Heat (L-M-H)
dB(A)
27 - 31 - 37 - 45
28 - 34 - 38 - 44
28 - 35 - 39 - 46
Outdoor Sound Pressure (Cool-Heat)
dB(A)
51 - 53
54 - 54
53 - 51
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
1/2" - 1/4"
5/8" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
25 - 15
30 - 20
30 - 20
Pre-charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
1.35 - 20g/m
1.55 - 25g/m
1.80 - 25g/m
Yes
Yes
Yes
Heating
Suitable for Replacement Tech.
Indoor Drain Connection
mm
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
24 to -15
VP16 (14id 16od)
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
6.8 - 7.0
8.1 - 7.6
9.1 - 9.1
Interconnecting Cables
POWER
SRK50ZM-S
kW
1.55 - 1.59
1.85 - 1.74
2.05 - 2.06
Start - Max Run Current
A
7.0 - 14.0
8.1 - 14.5
9.1 - 17.0
Suggested Fuse Size
A
16
20
20
£438
£587
£644
Power Consumption (Cool - Heat)
Indoor Unit
Outdoor Unit
£648
£810
£1,114
Retail Price
£1,086
£1,397
£1,758
New weekly timer function | Night setback | Outdoor silent operation mode | Optional hard wired controller with addition of SC-BIKN-E & RC-E5 | Gravity drain.
ampair.co.uk | 01707 378 670 | [email protected]
11
RAC Systems
Indoor Unit
RAC Systems
Wall Mounted Premium Inverter
SRK80ZR-S
Infrared Remote Controller
Included
PERFORMANCE
Outdoor Unit
SRC80ZR-S
kW
UK Cooling (Total - Sensible)
kW
7.6 - 6.3
Nominal Heating (Range)
kW
9.0 (2.1 - 10.5)
UK Heating
kW
EFFICIENCY
A++ / A+
ERP (Cool / Heat)
3.40 - 3.75
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
6.5
6.60 - 4.40
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
8.0 (2.3 - 9.0)
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Cooling
°C
46 to -15
°C
24 to -15
Indoor Unit Dimensions (H-W-D)
mm
339 - 1197 - 262
Outdoor Unit Dimensions (H-W-D)
Heating
mm
750 - 880 (+88) - 340
Weight (Indoor - Outdoor)
kg
16.5 - 58.5
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
173 - 292 - 337 - 392
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
225 - 307 355 - 442
Static Pressure
Pa
0
Indoor Sound Pressure Cool (UL-L-M-H)
dB(A)
26 - 39 - 44 - 47
Indoor Sound Pressure Heat (UL-L-M-H)
dB(A)
29 - 36 - 41 - 47
Outdoor Sound Pressure (Cool-Heat)
dB(A)
56 - 55
Pipe Sizes (Gas - Liquid)
in
5/8" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
Pre-charged for
m
15
Charge R410A (Factory - Additional)
kg
1.9 - 25g/m
Yes
Suitable for Replacement Tech.
Indoor Drain Connection
mm
VP16 (14id 16od)
Power Supply (Outdoor)
V-Ph-Hz
230 - 1 - 50
A
10.4 - 10.6
3 core + E
Interconnecting Cables
POWER
RAC Systems
Indoor Unit
Running Current (Cool - Heat)
kW
2.35 - 2.40
Start - Max Run Current
A
10.6 - 17.0
Suggested Fuse Size
A
Power Consumption (Cool - Heat)
Indoor Unit
20
£762
Outdoor Unit
£1,352
Retail Price
£2,114
New weekly timer function | Night setback | Outdoor silent operation mode | Optional hard wired controller with addition of SC-BIKN-E & RC-E5 | Gravity drain.
@amp_aircon |
amp-air-conditioning
12
RAC Systems
Wall Mounted Hyper Inverter
PERFORMANCE
Outdoor Unit
EFFICIENCY
SRK25ZMX-S
Included
Included
SRK35ZMX-S
Included
SRC20ZMX-S
SRC25ZMX-S
SRC35ZMX-S
2.0 (0.9 - 3.1)
2.55 (0.9 - 3.2)
3.5 (0.9 - 4.1)
Nominal Cooling (Range)
kW
UK Cooling (Total - Sensible)
kW
1.9 - 1.8
2.4 - 2.3
3.3 - 3.1
Nominal Heating (Range)
kW
2.5 (0.9 - 4.3)
3.13 (0.9 - 4.7)
4.3 (0.9 - 5.1)
UK Heating
kW
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Cooling
1.8
2.3
3.1
7.40 - 4.13
7.60 - 4.26
7.20 - 4.27
A++ / A+
A++ / A+
A++ / A+
5.71 - 5.56
5.20 - 5.26
4.14 - 4.48
A/A
A/A
A/A
Energy Label (Cool / Heat)
46 to -15
°C
21 to -15
°C
mm
309 - 890 - 220
309 - 890 - 220
309 - 890 - 220
Outdoor Unit Dimensions (H-W-D)
mm
595 - 780 (+62) - 290
595 - 780 (+62) - 290
595 - 780 (+62) - 290
kg
13.5 - 35.0
13.5 - 35.0
13.5 - 35.0
Indoor Unit Airflow Rate Max (UL-L-M-H)
l/s
105 - 117 - 158 - 200
105 - 125 - 167 - 217
108 - 133 - 183 - 233
Static Pressure
Pa
0
0
0
Indoor Sound Pressure Max (UL-L-M-H)
dB(A)
21 - 25 - 33 - 39
22 - 27 - 34 - 41
22 - 27 - 35 - 43
Outdoor Sound Pressure (Cool-Heat)
dB(A)
47 - 47
47 - 47
50 - 50
Pipe Sizes (Gas - Liquid)
in
3/8" - 1/4"
3/8" - 1/4"
3/8" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
15 - 10
15 - 10
15 - 10
Pre-charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
1.20 - n/a
1.20 - n/a
1.20 - n/a
Yes
Yes
Yes
REFRIGERANT & PIPEWORK
PHYSICAL
Indoor Unit Dimensions (H-W-D)
AIRFLOW
Heating
SOUND
AMBIENT
RANGE
SRK20ZMX-S
Weight (Indoor - Outdoor)
Suitable for Replacement Tech.
Indoor Drain Connection
mm
Power Supply (Outdoor)
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
1.8 - 2.3
2.4 - 2.9
3.8 - 4.4
kW
0.35 - 0.45
0.49 - 0.60
0.85 - 0.96
Start - Max Run Current
A
2.3 - 8.0
2.9 - 8.0
4.4 - 8.0
Suggested Fuse Size
A
Interconnecting Cables
POWER
VP16 (14id 16od)
Running Current (Cool - Heat)
Power Consumption (Cool - Heat)
Indoor Unit
13
13
13
£320
£348
£424
Outdoor Unit
£522
£556
£620
Retail Price
£842
£904
£1,044
New weekly timer function | Night setback | Outdoor silent operation mode | Optional hard wired controller with addition of SC-BIKN-E & RC-E5 | Gravity drain.
ampair.co.uk | 01707 378 670 | [email protected]
13
RAC Systems
Indoor Unit
Infrared Remote Controller
RAC Systems
Wall Mounted Hyper Inverter
SRK50ZMX-S
Infrared Remote Controller
PERFORMANCE
Outdoor Unit
EFFICIENCY
Included
SRC50ZMX-S
SRC60ZMX-S
5.0 (1.1 - 5.8)
6.1 (1.1 - 6.8)
kW
UK Cooling (Total - Sensible)
kW
4.8 - 3.7
5.7 - 4.2
Nominal Heating (Range)
kW
6.0 (0.6 - 7.7)
6.8 (0.6 - 8.2)
UK Heating
kW
4.3
4.8
6.70 - 4.60
6.00 - 4.36
ERP (Cool / Heat)
A++ / A++
A+ / A+
EER - COP (Cool - Heat)
3.85 - 4.41
3.26 - 4.07
A/A
Energy Label (Cool / Heat)
Cooling
21 to -15
°C
mm
309 - 890 - 220
309 - 890 - 220
Outdoor Unit Dimensions (H-W-D)
mm
640 - 800 (+71) - 290
640 -800 (+71) - 290
kg
13.5 - 45.0
13.5 - 45.0
Indoor Unit Airflow Rate Max (UL-L-M-H)
l/s
133 - 175 - 242 - 283
142 - 183 - 250 - 292
Static Pressure
Pa
0
0
Indoor Sound Pressure Max (UL-L-M-H)
dB(A)
26 - 33 - 40 - 48
27 - 34 - 41 - 51
Outdoor Sound Pressure (Cool-Heat)
dB(A)
54 - 50
54 - 54
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
Pre-charged for
m
15
15
Charge R410A (Factory - Additional)
kg
1.50 - 20g/m
1.50 - 20g/m
REFRIGERANT & PIPEWORK
PHYSICAL
Indoor Unit Dimensions (H-W-D)
AIRFLOW
Heating
A/A
46 to -15
°C
SOUND
AMBIENT
RANGE
SRK60ZMX-S
Included
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Weight (Indoor - Outdoor)
Yes
Suitable for Replacement Tech.
Indoor Drain Connection
mm
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
RAC Systems
Indoor Unit
Yes
VP16 (14id 16od)
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
5.7 - 6.0
8.2 - 7.3
kW
1.30 - 1.36
1.87 - 1.67
Start - Max Run Current
A
6.0 - 15.0
8.2 - 15.0
Suggested Fuse Size
A
Running Current (Cool - Heat)
Power Consumption (Cool - Heat)
Indoor Unit
20
20
£642
£678
Outdoor Unit
£973
£1,102
Retail Price
£1,615
£1,780
New weekly timer function | Night setback | Outdoor silent operation mode | Optional hard wired controller with addition of SC-BIKN-E & RC-E5 | Gravity drain.
@amp_aircon |
amp-air-conditioning
14
RAC Systems
Floor Standing Hyper Inverter
PERFORMANCE
Outdoor Unit
EFFICIENCY
SRF35ZMX-S
Included
Included
SRF50ZMX-S
Included
SRC25ZMX-S
SRC35ZMX-S
SRC50ZMX-S
2.5 (0.9 - 3.2)
3.5 (0.9 - 4.1)
5.0 (1.1 - 5.2)
Nominal Cooling (Range)
kW
UK Cooling (Total - Sensible)
kW
2.4 - 2.1
3.3 - 2.6
4.8 - 3.5
Nominal Heating (Range)
kW
3.4 (0.9 - 4.7)
4.5 (0.9 - 5.1)
6.0 (0.6 - 6.9)
UK Heating
kW
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Cooling
2.7
3.5
4.7
6.90 - 4.12
6.67 - 4.25
6.01 - 4.19
A++ / A+
A++ / A+
A+ / A+
4.80 - 4.70
3.93 - 4.00
3.60 - 3.90
A/A
A/A
A/A
Energy Label (Cool / Heat)
46 to -15
°C
21 to -15
°C
mm
600 - 860 - 238
600 - 860 - 238
600 - 860 - 238
Outdoor Unit Dimensions (H-W-D)
mm
595 - 780 (+62) - 290
595 - 780 (+62) - 290
640 - 800 (+71) - 290
kg
18.0 - 35.0
19.0 - 35.0
19.0 - 45.0
Indoor Unit Airflow Rate Max (UL-L-M-H)
l/s
110 - 128 - 137 - 175
123 - 135 - 138 - 178
127 - 157 - 167 - 200
Static Pressure
Pa
0
0
0
Indoor Sound Pressure Max (UL-L-M-H)
dB(A)
28 - 33 - 35 - 40
31 - 35 - 36 - 41
33 - 39 - 42 - 47
Outdoor Sound Pressure (Cool-Heat)
dB(A)
47 - 47
50 - 50
52 - 52
Pipe Sizes (Gas - Liquid)
in
3/8" - 1/4"
3/8" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
15 - 10
15 - 10
30 - 20
Pre-charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
1.20 - n/a
1.20 - n/a
1.50 - 20g/m
Yes
Yes
Yes
REFRIGERANT & PIPEWORK
PHYSICAL
Indoor Unit Dimensions (H-W-D)
AIRFLOW
Heating
SOUND
AMBIENT
RANGE
SRF25ZMX-S
Weight (Indoor - Outdoor)
Suitable for Replacement Tech.
Indoor Drain Connection
mm
Power Supply (Outdoor)
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
2.5 - 3.4
3.9 - 4.9
6.1 - 6.8
kW
0.52 - 0.72
0.89 - 1.12
1.39 - 1.54
Start - Max Run Current
A
3.4 - 8.0
4.9 - 8.0
6.8 - 15.0
Suggested Fuse Size
A
Interconnecting Cables
POWER
VP16 (14id 16od)
Running Current (Cool - Heat)
Power Consumption (Cool - Heat)
Indoor Unit
13
13
20
£632
£675
£786
Outdoor Unit
£556
£620
£973
Retail Price
£1,188
£1,295
£1,759
New weekly timer function | Night setback | Outdoor silent operation mode | Optional hard wired controller with addition of SC-BIKN-E & RC-E5.
ampair.co.uk | 01707 378 670 | [email protected]
15
RAC Systems
Indoor Unit
Infrared Remote Controller
RAC Systems
Compact Ducted Hyper Inverter
SRR25ZM-S
Infrared remote controller
PERFORMANCE
Outdoor unit
EFFICIENCY
2.5 (1.0 - 3.3)
3.5 (1.0 - 3.9)
kW
2.3 - 2.0
3.3 - 2.6
Nominal Heating (Range)
kW
3.4 (1.4 - 4.8)
4.2 (1.5 - 5.2)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SRC35ZMX-S
kW
2.7
3.3
6.43 - 4.08
6.31 - 4.02
A++ / A
A++ / A+
4.39 - 4.53
3.57 - 4.08
A/A
Cooling
Heating
A/A
46 to -15
°C
21 to -15
°C
Indoor Unit Dimensions (H-W-D)
mm
200 - 750 - 500
200 - 750 - 500
Outdoor Unit Dimensions (H-W-D)
mm
595 - 780 (+62) - 290
595 - 780 (+62) - 290
Weight (Indoor - Outdoor)
kg
20.5 - 35
20.5 - 35
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
75 - 108 - 133 - 152
83 - 117 - 142 - 167
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
100 - 133 - 150 - 167
108 - 142 - 158 - 175
Static Pressure (standard-upper)
Pa
Discharge Spigots
35
35
Rectangular 660 x 99
Rectangular 660 x 99
dB(A)
24 - 30 - 33 - 37
25 - 31 - 34 - 38
Indoor Sound Pressure Heat (UL-L-M-H)* dB(A)
28 - 34 - 37 - 40
29 - 35 - 38 - 42
Indoor Sound Pressure Cool (UL-L-M-H)*
SOUND
Included
SRC25ZMX-S
UK Cooling (Total - Sensible)
Energy Label (Cool / Heat)
dB(A)
47 - 47
50 - 50
Pipe Sizes (Gas - Liquid)
in
3/8" - 1/4"
3/8" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
15 - 10
15 - 10
Pre-charged for
m
15
15
Charge R410A (Factory - Additional)
kg
1.20 - n/a
1.20 - n/a
Outdoor Sound Pressure (Cool-Heat)
REFRIGERANT & PIPEWORK
SRR35ZM-S
Included
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Yes
Suitable for Replacement Tech.
Indoor Drain Connection
mm
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
RAC Systems
Indoor unit
Yes
VP25
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
2.9 - 3.7
4.5 - 4.8
kW
0.57 - 0.75
0.98 - 1.03
Start - Max Run Current
A
3.7
4.8 - 8.0
Suggested Fuse Size
A
16
16
Indoor Unit
£696
£773
Outdoor Unit
£556
£620
Retail Price
£1,252
£1,393
Running Current (Cool - Heat)
Power Consumption (Cool - Heat)
* Sound data with no duct work connected | 24 hour timer |Includes return air filter | Optional hard wired controller with addition of SC-BIKN-E & RC-E5.
@amp_aircon |
amp-air-conditioning
16
RAC Systems
Multi Split Systems
RAC Systems
The MHI multi split system allows a single
outdoor unit to serve a number of indoor units.
An extensive range is available with 5 external
units and 22 indoor units, in 6 different styles.
Number of
Indoors
2
2-3
2-4
4-5
4-6
Nominal
Cooling
4.5kW
6.0kW
8.0kW
10.0kW
12.5kW
Outdoor
Units
1Ph 18 - 19
Nominal Cooling
2.0
2.5
3.5
5.0
Wall Mounted
SRK ZM-S
20
20
20
20
20
Wall Mounted
SRK ZMX-S
21
21
21
21
21
Floor Standing
SRF ZMX-S
23
23
23
Compact Cassette
FDTC VF
22
22
22
22
Compact Ducted
SRR ZJ-S
24
24
24
24
Standard Ducted
FDUM VF
23
Ceiling
Suspended
FDEN VF
23
6.0
7.1
All units single phase | Page numbers shown in italics.
ampair.co.uk | 01707 378 670 | [email protected]
17
RAC Systems
SCM Multi Split Outdoor Units
RAC Systems
Outdoor Unit Model Number
SCM45ZM-S
SCM60ZM-S
SCM80ZM-S
Nominal Cooling (Range)
kW
4.5 (1.8 - 6.4)
6.0 (1.8 - 7.5)
8.0 (1.8 - 9.2)
Nominal Heating (Range)
kW
5.6 (1.4 - 7.4)
6.8 (1.5 - 7.8)
9.3 (1.5 - 9.8)
2
2-3
2-4
4.33 - 4.67
4.20 - 4.50
3.70 - 4.12
A/A
A/A
A/A
Number Of Indoor Units
EFF.
EER - COP (Cool - Heat)
REFRIGERANT & PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
AMBIENT
RANGE
Energy Label (Cool / Heat)
Cooling
°C
43 to -15
43 to -15
43 to -15
Heating
°C
24 to -15
24 to -15
24 to -15
Height
mm
640
640
750
Width
mm
850
850
880
Depth
mm
290
290
340
Weight
kg
47
49
62
dB(A)
47 - 49
50 - 52
54 - 54
Airflow Rate Cool - Heat
l/s
667 - 667
700 - 700
933 - 933
Max External Static Pressure
Pa
0
0
0
Gas Pipe Size**
in
3/8" x 2
3/8" x 3
3/8" x 4
Liquid Pipe Size**
in
1/4" x 2
1/4" x 3
1/4" x 4
Maximum Pipe Run (Per Unit)
M
25
25
25
Maximum Pipe Run (Total)
M
30
40
70
Maximum Height Difference
M
15
15
20
Sound Pressure Level (Cool-Heat)
Pre-Charged for
M
30
40
40
Factory Charge
kg
2.00
2.50
3.15
g/m
n/a
n/a
20g/m
No
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
20
25
25
kW
1.04 - 1.20
1.43 - 1.51
2.16 - 2.26
Additional Charge
Suitable For Replacement Tech.
Power Supply (Outdoor)
POWER
Suggested Fuse Size
Power Input Cool - Heat
Running Current Cool - Heat
A
4.6 - 5.3
6.5 - 6.8
9.4 - 10.0
Start - Max Run Current
A
5.0 - 14.0
7.0 - 17.0
10.0 - 20.0
3 core + E
3 core + E
3 core + E
Outdoor Unit
£1,135
£1,795
£2,308
Retail Price
£1,135
£1,795
£2,308
Interconnecting Cables
* Minimum number of indoor units is 4 except 2 SRK71ZM-S’s or 3 SRK-ZMX-S or in a combination with SRK71ZM-S or FDEN50 | ** Pipework size to be as per indoor unit | For
performance data when each indoor unit is combined with outdoor unit refer to separate table.
@amp_aircon |
amp-air-conditioning
18
RAC Systems
Outdoor Unit Model Number
EFF.
AMBIENT
RANGE
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT & PIPEWORK
SCM125ZM-S*
Nominal Cooling (Range)
kW
10.0 (1.8 - 12.0)
12.5 (1.8 - 14.0)
Nominal Heating (Range)
kW
120 (1.5 - 13.5)
13.5 (1.5 - 14.0)
Number Of Indoor Units
EER - COP (Cool - Heat)
Operating Range (Cooling)
4-5
4-6
3.50 - 4.10
3.21 - 4.15
A/A
A/A
°C
43 to -15
43 to -15
Energy Label (Cool / Heat)
°C
24 to -15
24 to -15
Height
mm
945
945
Width
mm
970
970
Depth
mm
370
370
Weight
kg
92
92
Operating Range (Heating)
dB(A)
56 - 59
57 - 60
Airflow Rate Cool - Heat
l/s
1250 - 1250
1250 - 1367
Max External Static Pressure
Pa
0
0
Gas Pipe Size**
in
3/8" x 5
3/8" x 6
Liquid Pipe Size**
in
1/4" x 5
1/4" x 6
Maximum Pipe Run (Per Unit)
m
25
25
Maximum Pipe Run (Total)
m
90
90
Maximum Height Difference
m
20
20
Pre-Charged for
m
50
50
Factory Charge
kg
6.00
6.00
g/m
20g/m
20g/m
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
30
30
kW
2.86 - 2.93
3.25 - 3.90
Running Current Cool - Heat
A
12.4 - 12.8
17.0 - 14.1
Start - Max Run Current
A
13.0 - 29.0
17.0 - 29.0
3 core + E
3 core + E
Sound Pressure Level (Cool-Heat)
Additional Charge
Suitable For Replacement Tech.
Power Supply (Outdoor)
Suggested Fuse Size
POWER
SCM100ZM-S*
Power Input Cool - Heat
Interconnecting Cables
Outdoor Unit
£3,253
£3,523
Retail Price
£3,253
£3,523
* Minimum number of indoor units is 4 except 2 SRK71ZM-S’s or 3 SRK-ZMX-S or in a combination with SRK71ZM-S or FDEN50 | ** Pipework size to be as per indoor unit | For
performance data when each indoor unit is combined with outdoor unit refer to separate table.
ampair.co.uk | 01707 378 670 | [email protected]
19
RAC Systems
SCM Multi Split Outdoor Units
RAC Systems
SCM Multi Split Indoor Units
PERF.
SRK35ZM-S
2.0
2.5
3.5
Nominal Heating
kW
2.7
3.4
4.5
294 - 798 - 229
mm
294 - 798 - 229
294 - 798 - 229
Indoor Weight
kg
9.5
9.5
9.5
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
80 - 88 - 93 - 130
83 - 88 - 100 - 132
83 - 90 - 107 - 168
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
75 - 83 - 105 - 163
77 - 85 - 108 - 177
80 - 102 - 157 - 213
Indoor Sound Pressure Cool (UL-L-M-H)
dB(A)
21 - 24 - 27 - 33
21 - 24 - 28 - 34
22 - 26 - 32 - 42
Indoor Sound Pressure Heat (UL-L-M-H)
dB(A)
21 - 24 - 31 - 36
21 - 24 - 31 - 39
22 - 25 - 37 - 43
in
3/8" - 1/4"
3/8" - 1/4"
3/8" - 1/4"
Power Supply (Location)
Outdoor
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
3 core + E
£264
£292
£342
Included
Included
Included
£264
£292
£342
POWER &
PIPEWORK
PHYSICAL
SRK25ZM-S
kW
SOUND & AIRFLOW
SRK20ZM-S
Nominal Cooling
Indoor Unit Dim. (H-W-D)
Pipe Sizes (Gas - Liquid)
Indoor Unit
Infrared Remote Controller
Retail Price
SRK ZM Wall Mounts Continued
SRK71ZR-S
7.1
kW
5.0
Nominal Heating
kW
5.8
8.0
Indoor Unit Dim. (H-W-D)
mm
294 - 798 - 229
339 - 1197 - 262
Indoor Weight
kg
9.5
15.5
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
88 - 100 - 130 - 188
173 - 270 - 310 - 342
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
103 - 125 - 170 - 225
222 - 270 - 310 - 342
Indoor Sound Pressure Cool (UL-L-M-H)
dB(A)
25 - 28 - 37 - 46
25 - 37 - 41 - 44
Indoor Sound Pressure Heat (UL-L-M-H)
dB(A)
27 - 31 - 37 - 45
28 - 35 - 39 - 46
in
1/2" - 1/4"
5/8" - 1/4"
PERF.
Nominal Cooling
PHYSICAL
SRK50ZM-S
SOUND & AIRFLOW
Indoor Unit
POWER &
PIPEWORK
RAC Systems
SRK ZM Wall Mounts
Indoor Unit
Pipe Sizes (Gas - Liquid)
Power Supply (Location)
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
£438
£644
Included
Included
£438
£644
Indoor Unit
Infrared Remote Controller
Retail Price
@amp_aircon |
amp-air-conditioning
20
RAC Systems
SCM Multi Split Indoor Units
PERF.
SRK35ZMX-S
2.0
2.5
3.5
Nominal Heating
kW
3.0
3.4
4.5
309 - 890 - 220
Indoor Unit Dim. (H-W-D)
mm
309 - 890 - 220
309 - 890 - 220
Indoor Weight
kg
13.5
13.5
13.5
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
83 - 105 - 133 - 192
83 - 105 - 150 - 208
83 - 108 - 158 - 225
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
105 - 117 - 158 - 200
105 - 125 - 167 - 217
108 - 133 - 183 - 233
Indoor Sound Pressure Cool (UL-L-M-H)
dB(A)
21 - 24 - 30 - 39
22 - 25 - 31 - 41
22 - 27 - 35 - 42
Indoor Sound Pressure Heat (UL-L-M-H)
dB(A)
21 - 25 - 33 - 38
21 - 27 - 34 - 41
22 - 25 - 33 - 43
in
3/8" - 1/4"
3/8" - 1/4"
3/8" - 1/4"
Power Supply (Location)
Outdoor
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
3 core + E
£320
£348
£424
Included
Included
Included
£320
£348
£424
POWER &
PIPEWORK
PHYSICAL
SRK25ZMX-S
kW
SOUND & AIRFLOW
SRK20ZMX-S
Nominal Cooling
Pipe Sizes (Gas - Liquid)
Indoor Unit
Infrared Remote Controller
Retail Price
SRK ZMX Wall Mounts Continued
SRK60ZMX-S
6.0
kW
5.0
Nominal Heating
kW
5.8
6.8
Indoor Unit Dim. (H-W-D)
mm
309 - 890 - 220
309 - 890 - 220
Indoor Weight
kg
13.5
13.5
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
117 - 133 - 183 - 225
117 - 142 - 208 - 242
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
133 - 175 - 242 - 283
142 - 183 - 250 - 292
Indoor Sound Pressure Cool (UL-L-M-H)
dB(A)
25 - 27 - 40 - 47
25 - 29 - 41 - 51
Indoor Sound Pressure Heat (UL-L-M-H)
dB(A)
26 - 33 - 40 - 48
27 - 34 - 41 - 48
in
1/2" - 1/4"
1/2" - 1/4"
POWER &
PIPEWORK
PERF.
Nominal Cooling
PHYSICAL
SRK50ZMX-S
SOUND & AIRFLOW
Indoor Unit
Pipe Sizes (Gas - Liquid)
Power Supply (Location)
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
£642
£678
Included
Included
£642
£678
Indoor Unit
Infrared Remote Controller
Retail Price
ampair.co.uk | 01707 378 670 | [email protected]
21
RAC Systems
SRK ZMX Wall Mounts
Indoor Unit
RAC Systems
SCM Multi Split Indoor Units
FDTC25VF
FDTC35VF
TC-PSA-25W-E
TC-PSA-25W-E
2.5
3.5
kW
Nominal Heating
kW
3.4
4.5
mm
248 (35) - 570 (700) - 570 (700)
248 (35) - 570 (700) - 570 (700)
Indoor Unit Dim. (H-W-D) (Grille)
Indoor Weight (Grille)
kg
15.0 (3.5)
15.0 (3.5)
Indoor Unit Airflow Rate Cool (L-M-H-PH)
l/s
108 - 133 - 150 - 167
117 - 150 - 158 - 183
Indoor Unit Airflow Rate Heat (L-M-H-PH)
l/s
117 - 142 - 158 - 175
133 - 150 - 167 - 192
Indoor Sound Pressure Cool (L-M-H-PH)
dB(A)
29 - 32 - 36 - 38
30 - 36 - 40 - 41
Indoor Sound Pressure Heat (L-M-H-PH)
dB(A)
29.5 - 33 - 38 - 39
32 - 35 - 42 - 43
in
3/8" - 1/4"
3/8" - 1/4"
POWER &
PIPEWORK
PHYSICAL
Nominal Cooling
SOUND & AIRFLOW
PERF.
Grille
Pipe Sizes (Gas - Liquid)
Power Supply (Location)
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
Indoor Unit
£523
£530
Grille
£140
£140
Hard Wired Controller - RC-E5
£63
£63
Retail Price
£726
£733
FDTC Compact Cassette Continued
Indoor Unit
FDTC50VF
FDTC60VF
TC-PSA-25W-E
TC-PSA-25W-E
kW
5.0
6.0
Nominal Heating
kW
5.8
6.8
248 (35) - 570 (700) - 570 (700)
PHYSICAL
Nominal Cooling
Indoor Unit Dim. (H-W-D) (Grille)
mm
248 (35) - 570 (700) - 570 (700)
Indoor Weight (Grille)
kg
15.0 (3.5)
15.0 (3.5)
SOUND & AIRFLOW
PERF.
Grille
Indoor Unit Airflow Rate Cool (L-M-H-PH)
l/s
117 - 150 - 192 - 225
117 - 167 - 225 - 225
Indoor Unit Airflow Rate Heat (L-M-H-PH)
l/s
133 - 150 - 192 - 225
133 - 167 - 225 - 225
Indoor Sound Pressure Cool (L-M-H-PH)
dB(A)
30 - 36 - 42 - 47
30 - 39 - 46 - 47
Indoor Sound Pressure Heat (L-M-H-PH)
dB(A)
32 - 36 - 42 - 47
32 - 39 - 46 - 47
in
1/2" - 1/4"
1/2" - 1/4"
Power Supply (Location)
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
POWER &
PIPEWORK
RAC Systems
FDTC Compact Cassette
Indoor Unit
Pipe Sizes (Gas - Liquid)
Indoor Unit
£562
£616
Grille
£140
£140
Hardwired Controller - RC-E5
£63
£63
Retail Price
£765
£819
@amp_aircon |
amp-air-conditioning
22
RAC Systems
SCM Multi Split Indoor Units
PERF.
SRF50ZMX-S
2.5
3.5
5.0
Nominal Heating
kW
3.4
4.5
5.8
600 - 860 - 238
Indoor Unit Dim. (H-W-D)
mm
600 - 860 - 238
600 - 860 - 238
Indoor Weight
kg
18
19
19
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
97 - 112 - 127 - 150
107 - 122 - 130 - 153
110 - 123 - 160 - 192
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
110 - 128 - 137 - 175
123 - 135 - 138 - 178
127 - 157 - 167 - 200
Indoor Sound Pressure Cool (UL-L-M-H)
dB(A)
26 - 29 - 32 - 40
28 - 32 - 34 - 41
32 - 35 - 42 - 46
Indoor Sound Pressure Heat (UL-L-M-H)
dB(A)
28 - 33 - 35 - 40
31 - 35 - 36 - 41
33 - 39 - 41 - 47
in
3/8" - 1/4"
3/8" - 1/4"
1/2" - 1/4"
Power Supply (Location)
Outdoor
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
3 core + E
£632
£675
£786
Included
Included
Included
£632
£675
£786
POWER &
PIPEWORK
PHYSICAL
SRF35ZMX-S
kW
SOUND & AIRFLOW
SRF25ZMX-S
Nominal Cooling
Pipe Sizes (Gas - Liquid)
Indoor Unit
Infrared Remote Controller
Retail Price
Indoor Unit
POWER &
PIPEWORK
SOUND &
PHYSICAL
AIRFLOW
PERF.
Grille / Spigot Kit
FDUM Standard Ducted
FDEN Ceiling Suspended
FDUM50VF
FDEN50VF
AMP-FDUM-2
n/a
5.0
5.0
Nominal Cooling
kW
Nominal Heating
KW
5.8
5.8
Indoor Unit Dim. (H-W-D)
mm
280 - 750 - 635
210 - 1070 - 690
Indoor Weight
kg
29.0
28.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
133 - 150 - 167 - 217
117 - 150 - 167 - 183
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
26 - 29 - 32 - 37
37 - 38 - 39 - 46
in
1/2" - 1/4"
1/2" - 1/4"
Pipe Sizes (Gas - Liquid)
Power Supply (Location)
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
Indoor Unit
£587
£677
Grille / Spigot Kit
£40
n/a
Hard Wired Controller - RC-E5
£63
£63
Retail Price
£690
£740
ampair.co.uk | 01707 378 670 | [email protected]
23
RAC Systems
SRF ZMX Floor Standing
Indoor Unit
RAC Systems
SCM Multi Split Indoor Units
PERF.
2.5
3.5
Nominal Heating
kW
3.4
4.5
200 - 750 - 500
mm
200 - 750 - 500
Indoor Weight
kg
20.5
20.5
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
75 - 108 - 133 - 158
83 - 116 - 141 - 167
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
100 - 135 - 150 - 167
108 - 141 - 158 - 175
Indoor Sound Pressure Cool (UL-L-M-H)*
dB(A)
24 - 30 - 33 - 37
25 - 31 - 34 - 38
Indoor Sound Pressure Heat (UL-L-M-H)* dB(A)
28 - 34 - 37 - 40
29 - 35 - 38 - 42
3/8" - 1/4"
3/8" - 1/4"
Power Supply (Location)
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
POWER &
PIPEWORK
PHYSICAL
SRR35ZM-S
kW
SOUND & AIRFLOW
SRR25ZM-S
Nominal Cooling
Indoor Unit Dim. (H-W-D)
Pipe Sizes (Gas - Liquid)
in
Indoor Unit
Infra Red Remote Controller
Retail Price
£696
£773
Included
Included
£696
£773
SRR Ducted Indoor Units Continued
SRR50ZM-S
SRR60ZM-S
5.0
6.0
kW
Nominal Heating
kW
5.8
6.8
mm
200 - 950 - 500
200 - 950 - 500
PHYSICAL
Nominal Cooling
Indoor Unit Dim. (H-W-D)
Indoor Weight
kg
24.0
24.0
SOUND & AIRFLOW
PERF.
Indoor Unit
Indoor Unit Airflow Rate Cool (UL-L-M-H)
l/s
125 - 167 - 183 - 225
133 - 175 - 192 - 242
Indoor Unit Airflow Rate Heat (UL-L-M-H)
l/s
141 - 183 - 208 - 233
150 - 175 - 192 - 242
Indoor Sound Pressure Cool (UL-L-M-H)*
dB(A)
29 - 34 - 37 - 41
30 - 35 - 38 - 44
Indoor Sound Pressure Heat (UL-L-M-H)* dB(A)
32 - 37 - 39 - 43
33 - 38 - 41 - 45
1/2" - 1/4"
1/2" - 1/4"
POWER &
PIPEWORK
RAC Systems
SRR Ducted Indoor Units
Indoor Unit
Pipe Sizes (Gas - Liquid)
in
Power Supply (Location)
Outdoor
Outdoor
Interconnecting Cables
3 core + E
3 core + E
Indoor Unit
Infra Red Remote Controller
Retail Price
£915
£998
Included
Included
£915
£998
* Sound data with no duct work connected
@amp_aircon |
amp-air-conditioning
24
RAC Systems
Power
Supply
Indoor Unit
Operating
Status
1 unit
230V
2 units
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
A
B
A
20
-
2.00
-
3.00
B
-
25
-
2.50
-
3.40
-
35
-
3.50
-
4.50
-
20
20
2.00
2.00
2.25
2.25
20
25
2.00
2.50
2.49
3.11
20
35
2.00
3.50
2.36
4.14
25
25
2.50
2.50
3.25
3.25
25
35
2.42
3.38
2.71
3.79
35
35
2.90
2.90
3.25
3.25
RAC Systems
Outdoor Unit - SCM45ZM-S
Combination Tables
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
Power
Supply
Operating
Status
1 unit
Outdoor Unit - SCM60ZM-S
2 units
230V
3 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
A
B
C
A
B
C
20
-
-
2.00
-
-
3.00
-
-
25
-
-
2.50
-
-
3.40
-
-
35
-
-
3.50
-
-
4.50
-
-
50
-
-
5.00
-
-
5.80
-
-
60
-
-
6.00
-
-
6.80
-
-
20
20
-
2.00
2.00
-
3.00
3.00
-
20
25
-
2.00
2.50
-
2.71
3.39
-
20
35
-
1.93
3.37
-
2.36
4.14
-
20
50
-
1.89
4.71
-
2.00
5.00
-
20
60
-
1.68
5.03
-
1.78
5.33
-
25
25
-
2.45
2.45
-
3.15
3.15
-
25
35
-
2.42
3.38
-
2.79
3.91
-
25
50
-
2.23
4.47
-
2.37
4.73
-
25
60
-
1.97
4.73
-
2.09
5.01
-
35
35
-
3.30
3.30
-
3.50
3.50
-
35
50
-
2.76
3.94
-
2.92
4.18
-
35
60
-
2.47
4.23
-
2.62
4.48
-
50
50
-
3.35
3.35
-
3.55
3.55
-
50
60
-
3.05
3.65
-
3.23
3.87
-
20
20
20
1.90
1.90
1.90
2.20
2.20
2.20
20
20
25
1.82
1.82
2.27
2.06
2.06
2.58
20
20
35
1.60
1.60
2.80
1.81
1.81
3.17
20
20
50
1.40
1.40
3.50
1.56
1.56
3.89
20
20
60
1.28
1.28
3.84
1.44
1.44
4.32
20
25
25
1.69
2.11
2.11
1.94
2.43
2.43
20
25
35
1.53
1.91
2.67
1.73
2.16
3.02
20
25
50
1.35
1.68
3.37
1.49
1.87
3.74
20
25
60
1.26
1.57
3.77
1.37
1.71
4.11
20
35
35
1.40
2.45
2.45
1.56
2.72
2.72
20
35
50
1.26
2.20
3.14
1.37
2.40
3.43
25
25
25
2.00
2.00
2.00
2.27
2.27
2.27
25
25
35
1.79
1.79
2.51
2.06
2.06
2.88
25
25
50
1.60
1.60
3.20
1.80
1.80
3.60
25
25
60
1.52
1.52
3.65
1.64
1.64
3.93
25
35
35
1.68
2.36
2.36
1.87
2.62
2.62
25
35
50
1.52
2.13
3.05
1.64
2.29
3.27
35
35
35
2.20
2.20
2.20
2.40
2.40
2.40
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected]
25
RAC Systems
Combination Tables
RAC Systems
Power
Supply
Operating
Status
1 unit
SCM80ZM-S
2 units
230V
3 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
A
B
C
D
A
B
C
20
-
-
-
2.00
-
-
-
3.00
-
-
D
-
25
-
-
-
2.50
-
-
-
3.40
-
-
-
35
-
-
-
3.50
-
-
-
4.50
-
-
50
-
-
-
5.00
-
-
-
5.80
-
-
-
60
-
-
-
6.00
-
-
-
6.80
-
-
-
20
20
-
-
2.00
2.00
-
-
2.70
2.70
-
-
20
25
-
-
2.00
2.50
-
-
2.62
3.28
-
-
20
35
-
-
2.00
3.50
-
-
2.51
4.39
-
-
20
50
-
-
1.97
4.93
-
-
2.37
5.93
-
-
20
60
-
-
1.85
5.55
-
-
2.08
6.23
-
-
25
25
-
-
2.50
2.50
-
-
3.20
3.20
-
-
25
35
-
-
2.46
3.44
-
-
3.08
4.32
-
-
25
50
-
-
2.47
4.93
-
-
2.77
5.53
-
-
25
60
-
-
2.18
5.22
-
-
2.44
5.86
-
-
35
35
-
-
3.45
3.45
-
-
4.15
4.15
-
-
35
50
-
-
3.05
4.35
-
-
3.42
4.88
-
-
35
60
-
-
2.73
4.67
-
-
3.06
5.24
-
-
50
50
-
-
3.70
3.70
-
-
4.15
4.15
-
-
50
60
-
-
3.36
4.04
-
-
3.77
4.53
-
-
60
60
-
-
3.70
3.70
-
-
4.15
4.15
-
-
20
20
20
-
2.00
2.00
2.00
-
2.57
2.57
2.57
-
20
20
25
-
2.00
2.00
2.50
-
2.46
2.46
3.08
-
20
20
35
-
1.89
1.89
3.31
-
2.27
2.27
3.97
-
20
20
50
-
1.73
1.73
4.33
-
2.00
2.00
5.00
-
20
20
60
-
1.56
1.56
4.68
-
1.80
1.80
5.40
-
20
25
25
-
1.94
2.43
2.43
-
2.34
2.93
2.93
-
20
25
35
-
1.88
2.34
3.28
-
2.20
2.75
3.85
-
20
25
50
-
1.64
2.05
4.11
-
1.89
2.37
4.74
-
20
25
60
-
1.49
1.86
4.46
-
1.71
2.14
5.14
-
20
35
35
-
1.73
3.03
3.03
-
2.00
3.50
3.50
-
20
35
50
-
1.49
2.60
3.71
-
1.71
3.00
4.29
-
20
35
60
-
1.36
2.37
4.07
-
1.57
2.74
4.70
-
20
50
50
-
1.30
3.25
3.25
-
1.50
3.75
3.75
-
20
50
60
-
1.20
3.00
3.60
-
1.38
3.46
4.15
-
25
25
25
-
2.37
2.37
2.37
-
2.83
2.83
2.83
-
25
25
35
-
2.29
2.29
3.21
-
2.65
2.65
3.71
-
25
25
50
-
1.95
1.95
3.90
-
2.25
2.25
4.50
-
25
25
60
-
1.77
1.77
4.25
-
2.05
2.05
4.91
-
25
35
35
-
2.05
2.87
2.87
-
2.37
3.32
3.32
-
25
35
50
-
1.77
2.48
3.55
-
2.05
2.86
4.09
-
25
35
60
-
1.63
2.28
3.90
-
1.88
2.63
4.50
-
25
50
50
-
1.56
3.12
3.12
-
1.80
3.60
3.60
-
25
50
60
-
1.44
2.89
3.47
-
1.67
3.33
4.00
-
35
35
35
-
2.60
2.60
2.60
-
3.00
3.00
3.00
-
35
35
50
-
2.28
2.28
3.25
-
2.63
2.63
3.75
-
35
35
60
-
2.10
2.10
3.60
-
2.42
2.42
4.15
-
35
50
50
-
2.02
2.89
2.89
-
2.33
3.33
3.33
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
@amp_aircon |
amp-air-conditioning
26
RAC Systems
Combination Tables
SCM80ZM-S
230V
Operating
Status
4 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
A
B
C
D
A
B
C
D
20
20
20
20
1.95
1.95
1.95
1.95
2.28
2.28
2.28
2.2.8
20
20
20
25
1.84
1.84
1.84
2.29
2.14
2.14
2.14
2.68
20
20
20
35
1.66
1.66
1.66
2.91
1.94
1.94
1.94
3.39
20
20
20
50
1.44
1.44
1.44
3.59
1.67
1.67
1.67
4.18
20
20
20
60
1.33
1.33
1.33
4.00
1.55
1.55
1.55
4.65
20
20
25
25
1.76
1.76
2.19
2.19
2.04
2.04
2.56
2.56
20
20
25
35
1.58
1.58
1.98
2.77
1.84
1.84
2.30
3.22
20
20
25
50
1.37
1.37
1.72
3.43
1.62
1.62
2.02
4.04
20
20
25
60
1.28
1.28
1.60
3.84
1.49
1.49
1.86
4.46
20
20
35
35
1.44
1.44
2.51
2.51
1.67
1.67
2.93
2.93
20
20
35
50
1.28
1.28
2.24
3.20
1.49
1.49
2.60
3.72
20
20
35
60
1.19
1.19
2.07
3.56
1.38
1.38
2.41
4.13
20
25
25
25
1.66
2.08
2.08
2.08
1.94
2.42
2.42
2.42
20
25
25
35
1.50
1.88
1.88
2.63
1.75
2.19
2.19
3.07
20
25
25
50
1.33
1.67
1.67
3.33
1.55
1.94
1.94
3.88
20
25
25
60
1.23
1.54
1.54
3.69
1.43
1.79
1.79
4.29
20
25
35
35
1.37
1.72
2.40
2.40
1.62
2.02
2.83
2.83
20
25
35
50
1.23
1.54
2.15
3.08
1.43
1.79
2.50
3.58
20
25
35
35
1.28
2.24
2.24
2.24
1.49
2.60
2.60
2.60
25
25
25
25
1.98
1.98
1.98
1.98
2.30
2.30
2.30
2.30
25
25
25
35
1.80
1.80
1.80
2.51
2.09
2.09
2.09
2.93
25
25
25
50
1.60
1.60
1.60
3.20
1.86
1.86
1.86
3.72
25
25
25
60
1.48
1.48
1.48
3.56
1.72
1.72
1.72
4.13
25
25
35
35
1.67
1.67
2.33
2.33
1.94
1.94
2.71
2.71
25
25
35
50
1.48
1.48
2.07
2.96
1.72
1.72
2.41
3.44
25
25
35
35
1.54
2.15
2.15
2.15
1.79
2.50
2.50
2.50
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
Power
Supply
Operating
Status
SCM100ZM-S
1 unit
230V
2 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
E
A
B
C
D
E
A
B
C
D
20
-
-
-
-
2.00
-
-
-
-
3.00
-
-
-
E
-
25
-
-
-
-
2.50
-
-
-
-
3.40
-
-
-
-
35
-
-
-
-
3.50
-
-
-
-
4.50
-
-
-
-
50
-
-
-
-
5.00
-
-
-
-
5.80
-
-
-
-
60
-
-
-
-
6.00
-
-
-
-
6.80
-
-
-
-
71
-
-
-
-
7.10
-
-
-
-
8.00
-
-
-
-
20
20
-
-
-
2.00
2.00
-
-
-
3.00
3.00
-
-
20
25
-
-
-
2.00
2.50
-
-
-
2.84
3.56
-
-
-
20
35
-
-
-
2.00
3.50
-
-
-
2.73
4.77
-
-
-
20
50
-
-
-
2.00
5.00
-
-
-
2.51
6.29
-
-
-
20
60
-
-
-
2.00
6.00
-
-
-
2.45
7.35
-
-
-
20
71
-
-
-
2.00
7.10
-
-
-
2.42
8.58
-
-
-
25
25
-
-
-
2.50
2.50
-
-
-
3.40
3.40
-
-
-
25
35
-
-
-
2.50
3.50
-
-
-
3.29
4.61
-
-
-
25
50
-
-
-
2.50
5.00
-
-
-
3.07
6.13
-
-
-
25
60
-
-
-
2.50
6.00
-
-
-
3.00
7.20
-
-
25
71
-
-
-
2.53
7.17
-
-
-
2.97
8.43
-
-
-
35
35
-
-
-
3.50
3.50
-
-
-
4.50
4.50
-
-
-
35
50
-
-
-
3.50
5.00
-
-
-
4.24
6.06
-
-
-
35
60
-
-
-
3.50
6.00
-
-
-
4.16
7.14
-
-
-
35
71
-
-
-
3.30
6.70
-
-
-
3.96
8.04
-
-
-
50
50
-
-
-
5.00
5.00
-
-
-
5.80
5.80
-
-
-
50
60
-
-
-
4.55
5.45
-
-
-
5.45
6.55
-
-
-
ampair.co.uk | 01707 378 670 | [email protected]
27
RAC Systems
Power
Supply
RAC Systems
SCM100ZM-S
Continued
Power
Supply
230V
Operating
Status
2 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
E
A
B
C
D
E
A
B
C
D
50
71
-
-
-
4.13
5.87
-
-
-
4.96
7.04
-
-
E
-
60
60
-
-
-
5.00
5.00
-
-
-
6.00
6.00
-
-
-
60
71
-
-
-
4.58
5.42
-
-
-
5.50
6.50
-
-
-
71
71
-
-
-
5.00
5.00
-
-
-
6.00
6.00
-
-
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
Power
Supply
SCM100ZM-S
RAC Systems
Combination Tables
230V
Operating
Status
3 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
E
A
B
C
D
E
A
B
C
D
20
20
20
-
-
2.00
2.00
2.00
-
-
3.00
3.00
3.00
-
E
-
20
20
25
-
-
2.00
2.00
2.50
-
-
2.89
2.89
3.62
-
-
20
20
35
-
-
2.00
2.00
3.50
-
-
2.80
2.80
4.90
-
-
20
20
50
-
-
2.00
2.00
5.00
-
-
2.62
2.62
6.56
-
-
20
20
60
-
-
2.00
2.00
6.00
-
-
2.40
2.40
7.20
-
-
20
20
71
-
-
1.80
1.80
6.40
-
-
2.16
2.16
7.68
-
-
20
25
25
-
-
2.00
2.50
2.50
-
-
2.80
3.50
3.50
-
20
25
35
-
-
2.00
2.50
3.50
-
-
2.73
3.41
4.77
-
-
20
25
50
-
-
2.00
2.50
5.00
-
-
2.53
3.16
6.32
-
-
20
25
60
-
-
1.90
2.38
5.71
-
-
2.29
2.86
6.86
-
-
20
25
71
-
-
1.72
2.16
6.12
-
-
2.07
2.59
7.34
-
-
20
35
35
-
-
2.00
3.50
3.50
-
-
2.67
4.67
4.67
-
-
20
35
50
-
-
1.90
3.33
4.76
-
-
2.29
4.00
5.71
-
-
20
35
60
-
-
1.74
3.04
5.22
-
-
2.09
3.65
6.26
-
-
20
35
71
-
-
1.59
2.78
5.63
-
-
1.90
3.33
6.76
-
-
20
50
50
-
-
1.67
4.17
4.17
-
-
2.00
5.00
5.00
-
20
50
60
-
-
1.54
3.85
4.62
-
-
1.85
4.62
5.54
-
-
20
50
71
-
-
1.42
3.55
5.04
-
-
1.70
4.26
6.04
-
-
20
60
60
-
-
1.43
4.29
4.29
-
-
1.71
5.14
5.14
-
-
20
60
71
-
-
1.32
3.97
4.70
-
-
1.59
4.77
5.64
-
-
25
25
25
-
-
2.50
2.50
2.50
-
-
3.40
3.40
3.40
-
-
25
25
35
-
-
2.50
2.50
3.50
-
-
3.32
3.32
4.65
-
-
25
25
50
-
-
2.50
2.50
5.00
-
-
3.00
3.00
6.00
-
-
25
25
60
-
-
2.27
2.27
5.45
-
-
2.73
2.73
6.55
-
-
25
25
71
-
-
2.07
2.07
5.87
-
-
2.48
2.48
7.04
-
25
35
35
-
-
2.50
3.50
3.50
-
-
3.16
4.42
4.42
-
-
25
35
50
-
-
2.27
3.18
4.55
-
-
2.73
3.82
5.45
-
-
25
35
60
-
-
2.08
2.92
5.00
-
-
2.50
3.50
6.00
-
-
25
35
71
-
-
1.91
2.67
5.42
-
-
2.29
3.21
6.50
-
-
25
50
50
-
-
2.00
4.00
4.00
-
-
2.40
4.80
4.80
-
-
25
50
60
-
-
1.85
3.70
4.44
-
-
2.22
4.44
5.33
-
-
25
50
71
-
-
1.71
3.42
4.86
-
-
2.05
4.11
5.84
-
-
25
60
60
-
-
1.72
4.14
4.14
-
-
2.07
4.97
4.97
-
-
25
60
71
-
-
1.60
3.85
4.55
-
-
1.92
4.62
5.46
-
35
35
35
-
-
3.33
3.33
3.33
-
-
4.00
4.00
4.00
-
-
35
35
50
-
-
2.92
2.92
4.17
-
-
3.50
3.50
5.00
-
-
-
35
35
60
-
35
35
71
-
2.69
2.69
4.62
-
-
3.23
3.23
5.54
-
-
2.48
2.48
5.04
-
-
2.98
2.98
6.04
-
-
35
50
50
-
-
2.59
3.70
3.70
-
-
3.11
4.44
4.44
-
-
35
50
60
-
-
2.41
3.45
4.14
-
-
2.90
4.14
4.97
-
-
35
50
71
-
-
2.24
3.21
4.55
-
-
2.69
3.85
5.46
-
-
35
60
60
-
-
2.26
3.87
3.87
-
-
2.71
4.65
4.65
-
-
50
50
50
-
-
3.33
3.33
3.33
-
-
4.00
4.00
4.00
-
-
50
50
60
-
-
3.13
3.13
3.75
-
-
3.75
3.75
4.50
-
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
@amp_aircon |
amp-air-conditioning
28
RAC Systems
Combination Tables
SCM100ZM-S
230V
Operating
Status
4 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
E
A
B
C
D
E
A
B
C
D
20
20
20
20
-
2.00
2.00
2.00
2.00
-
3.00
3.00
3.00
3.00
E
-
20
20
20
25
-
2.00
2.00
2.00
2.50
-
2.82
2.82
2.82
3.53
-
20
20
20
35
-
2.00
2.00
2.00
3.50
-
2.53
2.53
2.53
4.42
-
20
20
20
50
-
1.82
1.82
1.82
4.55
-
2.18
2.18
2.18
5.45
-
20
20
20
60
-
1.67
1.67
1.67
5.00
-
2.00
2.00
2.00
6.00
-
20
20
20
71
-
1.53
1.53
1.53
5.42
-
1.83
1.83
1.83
6.50
-
20
20
25
25
-
2.00
2.00
2.50
2.50
-
2.67
2.67
3.33
3.33
20
20
25
35
-
2.00
2.00
2.50
3.50
-
2.40
2.40
3.00
4.20
-
20
20
25
50
-
1.74
1.74
2.17
4.35
-
2.09
2.09
2.61
5.22
-
20
20
25
60
-
1.60
1.60
2.00
4.80
-
1.92
1.92
2.40
5.76
-
20
20
25
71
-
1.47
1.47
1.84
5.22
-
1.76
1.76
2.21
6.26
-
20
20
35
35
-
1.82
1.82
3.18
3.18
-
2.18
2.18
3.82
3.82
-
20
20
35
50
-
1.60
1.60
2.80
4.00
-
1.92
1.92
3.36
4.80
-
20
20
35
60
-
1.48
1.48
2.59
4.44
-
1.78
1.78
3.11
5.33
-
20
20
35
71
-
1.37
1.37
2.40
4.86
-
1.64
1.64
2.88
5.84
-
20
20
50
50
-
1.43
1.43
3.57
3.57
-
1.71
1.71
4.29
4.29
20
20
50
60
-
1.33
1.33
3.33
4.00
-
1.60
1.60
4.00
4.80
-
20
20
60
60
-
1.25
1.25
3.75
3.75
-
1.50
1.50
4.50
4.50
-
20
25
25
25
-
2.00
2.50
2.50
2.50
-
2.53
3.16
3.16
3.16
-
20
25
25
35
-
1.90
2.38
2.38
3.33
-
2.29
2.86
2.86
4.00
-
20
25
25
50
-
1.67
2.08
2.08
4.17
-
2.00
2.50
2.50
5.00
-
20
25
25
60
-
1.54
1.92
1.92
4.62
-
1.85
2.31
2.31
5.54
-
20
25
25
71
-
1.46
1.81
1.81
4.93
-
1.70
2.13
2.13
6.04
-
20
25
35
35
-
1.74
2.17
3.04
3.04
-
2.09
2.61
3.65
3.65
-
20
25
35
50
-
1.54
1.92
2.69
3.85
-
1.85
2.31
3.23
4.62
20
25
35
60
-
1.43
1.79
2.50
4.29
-
1.71
2.14
3.00
5.14
-
20
25
35
71
-
1.32
1.66
2.32
4.70
-
1.59
1.99
2.78
5.64
-
20
25
50
50
-
1.38
1.72
3.45
3.45
-
1.66
2.07
4.14
4.14
-
20
25
50
60
-
1.29
1.61
3.23
3.87
-
1.55
1.94
3.87
4.65
-
20
35
35
35
-
1.60
2.80
2.80
2.80
-
1.92
3.36
3.36
3.36
-
20
35
35
50
-
1.43
2.50
2.50
3.57
-
1.71
3.00
3.00
4.29
-
20
35
35
60
-
1.33
2.33
2.33
4.00
-
1.60
2.80
2.80
4.80
-
20
35
50
50
-
1.29
2.26
3.23
3.23
-
1.55
2.71
3.87
3.87
-
25
25
25
25
-
2.50
2.50
2.50
2.50
-
3.00
3.00
3.00
3.00
25
25
25
35
-
2.27
2.27
2.27
3.18
-
2.73
2.73
2.73
3.82
-
25
25
25
50
-
2.00
2.00
2.00
4.00
-
2.40
2.40
2.40
4.80
-
-
25
25
25
60
25
25
25
71
1.85
1.85
1.85
4.44
-
2.22
2.22
2.22
5.33
-
1.71
1.71
1.71
4.86
-
2.05
2.05
2.05
5.84
-
25
25
35
35
-
2.08
2.08
2.92
2.92
-
2.50
2.50
3.50
3.50
-
25
25
35
50
-
1.85
1.85
2.59
3.70
-
2.22
2.22
3.11
4.44
-
25
25
35
60
-
1.72
1.72
2.41
4.14
-
2.07
2.07
2.90
4.97
-
25
25
35
71
-
1.60
1.60
2.24
4.55
-
1.92
1.92
2.69
5.46
-
25
25
50
50
-
1.67
1.67
3.33
3.33
-
2.00
2.00
4.00
4.00
25
25
50
60
-
1.56
1.56
3.13
3.75
-
1.88
1.88
3.75
4.50
-
25
35
35
35
-
1.92
2.69
2.69
2.69
-
2.31
3.23
3.23
3.23
-
25
35
35
50
-
1.72
2.41
2.41
3.45
-
2.07
2.90
2.90
4.14
-
25
35
35
60
-
1.61
2.26
2.26
3.87
-
1.94
2.71
2.71
4.65
-
25
35
50
50
-
1.56
2.19
3.13
3.13
-
1.88
2.63
3.75
3.75
-
35
35
35
35
-
2.50
2.50
2.50
2.50
-
3.00
3.00
3.00
3.00
-
35
35
35
50
-
2.26
2.26
2.26
3.23
-
2.71
2.71
2.71
3.87
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected]
29
RAC Systems
Power
Supply
RAC Systems
Combination Tables
Operating
Status
SCM100ZM-S
RAC Systems
Power
Supply
230V
5 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
E
A
B
C
D
E
A
B
C
D
E
20
20
20
20
20
2.00
2.00
2.00
2.00
2.00
2.40
2.40
2.40
2.40
2.40
20
20
20
20
25
1.90
1.90
1.90
1.90
2.38
2.29
2.29
2.29
2.29
2.86
20
20
20
20
35
1.74
1.74
1.74
1.74
3.04
2.09
2.09
2.09
2.09
3.65
20
20
20
20
50
1.54
1.54
1.54
1.54
3.85
1.85
1.85
1.85
1.85
4.62
20
20
20
20
60
1.43
1.43
1.43
1.43
4.29
1.71
1.71
1.71
1.71
5.14
20
20
20
20
71
1.32
1.32
1.32
1.32
4.70
1.59
1.59
1.59
1.59
5.64
20
20
20
25
25
1.82
1.82
1.82
2.27
2.27
2.18
2.18
2.18
2.73
2.73
20
20
20
25
35
1.67
1.67
1.67
2.08
2.92
2.00
2.00
2.00
2.50
3.50
20
20
20
25
50
1.48
1.48
1.48
1.85
3.70
1.78
1.78
1.78
2.22
4.44
20
20
20
25
60
1.38
1.38
1.38
1.72
4.14
1.66
1.66
1.66
2.07
4.97
20
20
20
25
71
1.28
1.28
1.28
1.60
4.55
1.54
1.54
1.54
1.92
5.46
20
20
20
35
35
1.54
1.54
1.54
2.69
2.69
1.85
1.85
1.85
3.23
3.23
20
20
20
35
50
1.38
1.38
1.38
2.41
3.45
1.66
1.66
1.66
2.90
4.14
20
20
20
35
60
1.29
1.29
1.29
2.26
3.87
1.55
1.55
1.55
2.71
4.65
20
20
20
50
50
1.25
1.25
1.25
3.13
3.13
1.50
1.50
1.50
3.75
3.75
20
20
25
25
25
1.74
1.74
2.17
2.17
2.17
2.09
2.09
2.61
2.61
2.61
20
20
25
25
35
1.60
1.60
2.00
2.00
2.80
1.92
1.92
2.40
2.40
3.36
20
20
25
25
50
1.43
1.43
1.79
1.79
3.57
1.71
1.71
2.14
2.14
4.29
20
20
25
25
60
1.33
1.33
1.67
1.67
4.00
1.60
1.60
2.00
2.00
4.80
20
20
25
35
35
1.48
1.48
1.85
2.59
2.59
1.78
1.78
2.22
3.11
3.11
20
20
25
35
50
1.33
1.33
1.67
2.33
3.33
1.60
1.60
2.00
2.80
4.00
20
20
25
35
60
1.25
1.25
1.56
2.19
3.75
1.50
1.50
1.88
2.63
4.50
20
20
35
35
35
1.38
1.38
2.41
2.41
2.41
1.66
1.66
2.90
2.90
2.90
20
20
35
35
50
1.25
1.25
2.19
2.19
3.13
1.50
1.50
2.63
2.63
3.75
20
25
25
25
25
1.67
2.08
2.08
2.08
2.08
2.00
2.50
2.50
2.50
2.50
20
25
25
25
35
1.54
1.92
1.92
1.92
2.69
1.85
2.31
2.31
2.31
3.23
20
25
25
25
50
1.38
1.72
1.72
1.72
3.45
1.66
2.07
2.07
2.07
4.14
20
25
25
25
60
1.29
1.61
1.61
1.61
3.87
1.55
1.94
1.94
1.94
4.65
20
25
25
35
35
1.43
1.79
1.79
2.50
2.50
1.71
2.14
2.14
3.00
3.00
20
25
25
35
50
1.29
1.61
1.61
2.26
3.23
1.55
1.94
1.94
2.71
3.87
20
25
35
35
35
1.33
1.67
2.33
2.33
2.33
1.60
2.00
2.80
2.80
2.80
20
35
35
35
35
1.25
2.19
2.19
2.19
2.19
1.50
2.63
2.63
2.63
2.63
25
25
25
25
25
2.00
2.00
2.00
2.00
2.00
2.40
2.40
2.40
2.40
2.40
25
25
25
25
35
1.85
1.85
1.85
1.85
2.59
2.22
2.22
2.22
2.22
3.11
25
25
25
25
50
1.67
1.67
1.67
1.67
3.33
2.00
2.00
2.00
2.00
4.00
25
25
25
25
60
1.56
1.56
1.56
1.56
3.75
1.88
1.88
1.88
1.88
4.50
25
25
25
35
35
1.72
1.72
1.72
2.41
2.41
2.07
2.07
2.07
2.90
2.90
25
25
25
35
50
1.56
1.56
1.56
2.19
3.13
1.88
1.88
1.88
2.63
3.75
25
25
35
35
35
1.61
1.61
2.26
2.26
2.26
1.94
1.94
2.71
2.71
2.71
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
@amp_aircon |
amp-air-conditioning
30
RAC Systems
Combination Tables
Operating
Status
SCM125ZM-S
1 unit
230V
2 units
Indoor Unit
Cooling Capacity (kW)
Heating Capacity (kW)
A
B
C
D
E
F
A
B
C
D
E
F
A
B
C
D
E
F
20
-
-
-
-
-
2.00
-
-
-
-
-
3.00
-
-
-
-
-
25
-
-
-
-
-
2.50
-
-
-
-
-
3.40
-
-
-
-
-
35
-
-
-
-
-
3.50
-
-
-
-
-
4.50
-
-
-
-
-
50
-
-
-
-
-
5.00
-
-
-
-
-
5.80
-
-
-
-
-
60
-
-
-
-
-
6.00
-
-
-
-
-
6.80
-
-
-
-
-
71
-
-
-
-
-
7.10
-
-
-
-
-
8.00
-
-
-
-
-
20
20
-
-
-
-
2.00 2.00
-
-
-
-
3.00 3.00
-
-
-
-
20
25
-
-
-
-
2.00 2.50
-
-
-
-
2.84 3.56
-
-
-
-
20
35
-
-
-
-
2.00 3.50
-
-
-
-
2.73 4.77
-
-
-
-
20
50
-
-
-
-
2.00 5.00
-
-
-
-
2.51 6.29
-
-
-
-
20
60
-
-
-
-
2.00 6.00
-
-
-
-
2.45 7.35
-
-
-
-
20
71
-
-
-
-
2.00 7.10
-
-
-
-
2.42 8.58
-
-
-
-
25
25
-
-
-
-
2.50 2.50
-
-
-
-
3.40 3.40
-
-
-
-
25
35
-
-
-
-
2.50 3.50
-
-
-
-
3.29 4.61
-
-
-
-
25
50
-
-
-
-
2.50 5.00
-
-
-
-
3.07 6.13
-
-
-
-
25
60
-
-
-
-
2.50 6.00
-
-
-
-
3.00 7.20
-
-
-
-
25
71
-
-
-
-
2.53 7.17
-
-
-
-
2.97 8.43
-
-
-
-
35
35
-
-
-
-
3.50 3.50
-
-
-
-
4.50 4.50
-
-
-
-
35
50
-
-
-
-
3.50 5.00
-
-
-
-
4.24 6.06
-
-
-
-
35
60
-
-
-
-
3.50 6.00
-
-
-
-
4.16 7.14
-
-
-
-
35
71
-
-
-
-
3.50 7.10
-
-
-
-
4.13 8.37
-
-
-
-
50
50
-
-
-
-
5.00 5.00
-
-
-
-
5.80 5.80
-
-
-
-
50
60
-
-
-
-
5.00 6.00
-
-
-
-
5.73 6.87
-
-
-
-
50
71
-
-
-
-
4.96 7.04
-
-
-
-
5.58 7.92
-
-
-
-
60
60
-
-
-
-
6.00 6.00
-
-
-
-
6.75 6.75
-
-
-
-
60
71
-
-
-
-
5.73 6.77
-
-
-
-
6.18 7.32
-
-
-
-
71
71
-
-
-
-
6.25 6.25
-
-
-
-
6.75 6.75
-
-
-
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected]
31
RAC Systems
Power
Supply
RAC Systems
Combination Tables
Operating
Status
SCM125ZM-S
RAC Systems
Power
Supply
230V
3 units
Indoor Unit
Cooling Capacity (kW)
A
B
C
D
E
F
20
20
20
-
-
-
20
20
25
-
-
20
20
35
-
20
20
50
20
20
20
A
B
C
Heating Capacity (kW)
D
E
F
A
D
E
F
2.00 2.00 2.00
-
-
-
3.00 3.00 3.00
B
C
-
-
-
-
2.00 2.00 2.50
-
-
-
2.89 2.89 3.62
-
-
-
-
-
2.00 2.00 3.50
-
-
-
2.80 2.80 4.90
-
-
-
-
-
-
2.00 2.00 5.00
-
-
-
2.62 2.62 6.56
-
-
-
60
-
-
-
2.00 2.00 6.00
-
-
-
2.56 2.56 7.68
-
-
-
20
71
-
-
-
2.00 2.00 7.10
-
-
-
2.43 2.43 8.64
-
-
-
20
25
25
-
-
-
2.00 2.50 2.50
-
-
-
2.80 3.50 3.50
-
-
-
20
25
35
-
-
-
2.00 2.50 3.50
-
-
-
2.73 3.41 4.77
-
-
-
20
25
50
-
-
-
2.00 2.50 5.00
-
-
-
2.57 3.21 6.42
-
-
-
20
25
60
-
-
-
2.00 2.50 6.00
-
-
-
2.51 3.14 7.54
-
-
-
20
25
71
-
-
-
2.00 2.50 7.10
-
-
-
2.33 2.91 8.26
-
-
-
20
35
35
-
-
-
2.00 3.50 3.50
-
-
-
2.67 4.67 4.67
-
-
-
20
35
50
-
-
-
2.00 3.50 5.00
-
-
-
2.53 4.43 6.33
-
-
-
20
35
60
-
-
-
2.00 3.50 6.00
-
-
-
2.35 4.11 7.04
-
-
-
20
35
71
-
-
-
1.98 3.47 7.04
-
-
-
2.14 3.75 7.61
-
-
-
20
50
50
-
-
-
2.00 5.00 5.00
-
-
-
2.25 5.63 5.63
-
-
-
20
50
60
-
-
-
1.92 4.81 5.77
-
-
-
2.08 5.19 6.23
-
-
-
20
50
71
-
-
-
1.77 4.43 6.29
-
-
-
1.91 4.79 6.80
-
-
-
20
60
60
-
-
-
1.79 5.36 5.36
-
-
-
1.93 5.79 5.79
-
-
-
20
60
71
-
-
-
1.66 4.97 5.88
-
-
-
1.79 5.36 6.35
-
-
-
20
71
71
-
-
-
1.54 5.48 5.48
-
-
-
1.67 5.92 5.92
-
-
-
25
25
25
-
-
-
2.50 2.50 2.50
-
-
-
3.40 3.40 3.40
-
-
-
25
25
35
-
-
-
2.50 2.50 3.50
-
-
-
3.32 3.32 4.65
-
-
-
25
25
50
-
-
-
2.50 2.50 5.00
-
-
-
3.15 3.15 6.30
-
-
-
25
25
60
-
-
-
2.50 2.50 6.00
-
-
-
3.07 3.07 7.36
-
-
-
25
25
71
-
-
-
2.58 2.58 7.33
2.79 2.79 7.92
-
-
-
25
35
35
-
-
-
2.50 3.50 3.50
-
-
-
3.26 4.57 4.57
-
-
-
25
35
50
-
-
-
2.50 3.50 5.00
-
-
-
3.07 4.30 6.14
-
-
-
25
35
60
-
-
-
2.50 3.50 6.00
-
-
-
2.81 3.94 6.75
-
-
-
25
35
71
-
-
-
2.39 3.34 6.77
-
-
-
2.58 3.61 7.32
-
-
-
25
50
50
-
-
-
2.50 5.00 5.00
-
-
-
2.70 5.40 5.40
-
-
-
25
50
60
-
-
-
2.31 4.63 5.56
-
-
-
2.50 5.00 6.00
-
-
-
25
50
71
-
-
-
2.14 4.28 6.08
-
-
-
2.31 4.62 6.57
-
-
-
25
60
60
-
-
-
2.16 5.17 5.17
-
-
-
2.33 5.59 5.59
-
-
-
25
60
71
-
-
-
2.00 4.81 5.69
-
-
-
2.16 5.19 6.14
-
-
-
25
71
71
-
-
-
1.87 5.31 5.31
-
-
-
2.02 5.74 5.74
-
-
-
35
35
35
-
-
-
3.50 3.50 3.50
-
-
-
4.50 4.50 4.50
-
-
-
35
35
50
-
-
3.50 3.50 5.00
-
-
-
3.94 3.94 5.63
-
-
-
35
35
60
-
-
-
3.37 3.37 5.77
-
-
-
3.63 3.63 6.23
-
-
-
35
35
71
-
-
-
3.10 3.10 6.29
-
-
-
3.35 3.35 6.80
-
-
-
35
50
50
-
-
-
3.24 4.63 4.63
-
-
-
3.50 5.00 5.00
-
-
-
35
50
60
-
-
-
3.02 4.31 5.17
-
-
-
3.26 4.66 5.59
-
-
-
35
50
71
-
-
-
2.80 4.01 5.69
-
-
-
3.03 4.33 6.14
-
-
-
35
60
60
-
-
-
2.82 4.84 4.84
-
-
-
3.05 5.23 5.23
-
-
-
35
60
71
-
-
-
2.64 4.52 5.35
-
-
-
2.85 4.88 5.77
-
-
-
35
71
71
-
-
-
2.47 5.01 5.01
-
-
-
2.67 5.42 5.42
-
-
-
50
50
50
-
-
-
4.17 4.17 4.17
-
-
-
4.50 4.50 4.50
-
-
-
50
50
60
-
-
-
3.91 3.91 4.69
-
-
-
4.22 4.22 5.06
-
-
-
50
50
71
-
-
-
3.65 3.65 5.19
-
-
-
3.95 3.95 5.61
-
-
-
50
60
60
-
-
-
3.68 4.41 4.41
-
-
-
3.97 4.76 4.76
-
-
-
50
60
71
-
-
-
3.45 4.14 4.90
-
-
-
3.73 4.48 5.30
-
-
-
60
60
60
-
-
-
4.17 4.17 4.17
-
-
-
4.50 4.50 4.50
-
-
-
60
60
71
-
-
-
3.93 3.93 4.65
-
-
-
4.24 4.24 5.02
-
-
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
@amp_aircon |
amp-air-conditioning
32
RAC Systems
SCM125ZM-S
Combination Tables
Operating
Status
230V
4 units
Indoor Unit
Cooling Capacity (kW)
A
B
C
D
E
F
20
20
20
20
-
-
20
20
20
25
-
20
20
20
35
20
20
20
20
20
20
A
B
C
D
Heating Capacity (kW)
E
F
A
E
F
2.00 2.00 2.00 2.00
-
-
3.00 3.00 3.00 3.00
B
C
D
-
-
-
2.00 2.00 2.00 2.50
-
-
2.92 2.92 2.92 3.65
-
-
-
-
2.00 2.00 2.00 3.50
-
-
2.84 2.84 2.84 4.97
-
-
50
-
-
2.00 2.00 2.00 5.00
-
-
2.45 2.45 2.45 6.14
-
-
20
60
-
-
2.00 2.00 2.00 6.00
-
-
2.25 2.25 2.25 6.75
-
-
20
20
71
-
-
1.91 1.91 1.91 6.77
-
-
2.06 2.06 2.06 7.32
-
-
20
20
25
25
-
-
2.00 2.00 2.50 2.50
-
-
2.84 2.84 3.56 3.56
-
-
20
20
25
35
-
-
2.00 2.00 2.50 3.50
-
-
2.70 2.70 3.38 4.73
-
-
20
20
25
50
-
-
2.00 2.00 2.50 5.00
-
-
2.35 2.35 2.93 5.87
-
-
20
20
25
60
-
-
2.00 2.00 2.50 6.00
-
-
2.16 2.16 2.70 6.48
-
-
20
20
25
71
-
-
1.84 1.84 2.30 6.53
-
-
1.99 1.99 2.48 7.05
-
-
20
20
35
35
-
-
2.00 2.00 3.50 3.50
-
-
2.45 2.45 4.30 4.30
-
-
20
20
35
50
-
-
2.00 2.00 3.50 5.00
-
-
2.16 2.16 3.78 5.40
-
-
20
20
35
60
-
-
1.85 1.85 3.24 5.56
-
-
2.00 2.00 3.50 6.00
-
-
20
20
35
71
-
-
1.71 1.71 3.00 6.08
-
-
1.85 1.85 3.24 6.57
-
-
20
20
50
50
-
-
1.79 1.79 4.46 4.46
-
-
1.93 1.93 4.82 4.82
-
-
20
20
50
60
-
-
1.67 1.67 4.17 5.00
-
-
1.80 1.80 4.50 5.40
-
-
20
20
50
71
-
-
1.55 1.55 3.88 5.51
-
-
1.68 1.68 4.19 5.95
-
-
20
20
60
60
-
-
1.56 1.56 4.69 4.69
-
-
1.69 1.69 5.06 5.06
-
-
20
20
60
71
-
-
1.46 1.46 4.39 5.19
-
-
1.58 1.58 4.74 5.61
-
-
20
20
71
71
-
-
1.37 1.37 4.88 4.88
-
-
1.48 1.48 5.27 5.27
-
-
20
25
25
25
-
-
2.00 2.50 2.50 2.50
-
-
2.78 3.47 3.47 3.47
-
-
20
25
25
35
-
-
2.00 2.50 2.50 3.50
-
-
2.57 3.21 3.21 4.50
-
-
20
25
25
50
-
-
2.00 2.50 2.50 5.00
-
-
2.25 2.81 2.81 5.63
-
-
20
25
25
60
-
-
1.92 2.40 2.40 5.77
-
-
2.08 2.60 2.60 6.23
-
-
20
25
25
71
-
-
1.82 2.26 2.26 6.16
-
-
1.91 2.39 2.39 6.80
-
-
20
25
35
35
-
-
2.00 2.50 3.50 3.50
-
-
2.35 2.93 4.11 4.11
-
-
20
25
35
50
-
-
1.92 2.40 3.37 4.81
-
-
2.08 2.60 3.63 5.19
-
-
20
25
35
60
-
-
1.79 2.23 3.13 5.36
-
-
1.93 2.41 3.38 5.79
-
-
20
25
35
71
-
-
1.66 2.07 2.90 5.88
-
-
1.79 2.24 3.13 6.35
-
-
20
25
50
50
-
-
1.72 2.16 4.31 4.31
-
-
1.86 2.33 4.66 4.66
-
-
20
25
50
60
-
-
1.61 2.02 4.03 4.84
-
-
1.74 2.18 4.35 5.23
-
-
20
25
50
71
-
-
1.51 1.88 3.77 5.35
-
-
1.63 2.03 4.07 5.77
-
-
20
25
60
60
-
-
1.52 1.89 4.55 4.55
-
-
1.64 2.05 4.91 4.91
-
-
20
25
60
71
-
-
1.42 1.78 4.26 5.04
-
-
1.53 1.92 4.60 5.45
-
-
20
25
71
71
-
-
1.34 1.67 4.75 4.75
-
-
1.44 1.80 5.13 5.13
-
-
20
35
35
35
-
-
2.00 3.50 3.50 3.50
-
-
2.16 3.78 3.78 3.78
-
-
20
35
35
50
-
1.79 3.13 3.13 4.46
-
-
1.93 3.38 3.38 4.82
-
-
20
35
35
60
-
-
1.67 2.92 2.92 5.00
-
-
1.80 3.15 3.15 5.40
-
-
20
35
35
71
-
-
1.55 2.72 2.72 5.51
-
-
1.68 2.93 2.93 5.95
-
-
20
35
50
50
-
-
1.61 2.82 4.03 4.03
-
-
1.74 3.05 4.35 4.35
-
-
20
35
50
60
-
-
1.52 2.65 3.79 4.55
-
-
1.64 2.86 4.09 4.91
-
-
20
35
50
71
-
-
1.42 2.49 3.55 5.04
-
-
1.53 2.68 3.84 5.45
-
-
20
35
60
60
-
-
1.43 2.50 4.29 4.29
-
-
1.54 2.70 4.63 4.63
-
-
20
35
60
71
-
-
1.34 2.35 4.03 4.77
-
-
1.45 2.54 4.35 5.15
-
-
20
50
50
50
-
-
1.47 3.68 3.68 3.68
-
-
1.59 3.97 3.97 3.97
-
-
20
50
50
60
-
-
1.39 3.47 3.47 4.17
-
-
1.50 3.75 3.75 4.50
-
-
20
50
50
71
-
-
1.31 3.27 3.27 4.65
-
-
1.41 3.53 3.53 5.02
-
-
20
50
60
60
-
-
1.32 3.29 3.95 3.95
-
-
1.42 3.55 4.26 4.26
-
-
25
25
25
25
-
-
2.50 2.50 2.50 2.50
-
-
3.38 3.38 3.38 3.38
-
-
Continued overleaf.
ampair.co.uk | 01707 378 670 | [email protected]
33
RAC Systems
Power
Supply
RAC Systems
Combination Tables
Operating
Status
SCM125ZM-S Continued
RAC Systems
Power
Supply
230V
4 units
Indoor Unit
Cooling Capacity (kW)
A
B
C
D
E
F
25
25
25
35
-
-
25
25
25
50
-
25
25
25
60
25
25
25
25
25
25
A
B
C
D
Heating Capacity (kW)
E
F
A
E
F
2.50 2.50 2.50 3.50
-
-
3.07 3.07 3.07 4.30
B
C
D
-
-
-
2.50 2.50 2.50 5.00
-
-
2.70 2.70 2.70 5.40
-
-
-
-
2.31 2.31 2.31 5.56
-
-
2.50 2.50 2.50 6.00
-
-
71
-
-
2.14 2.14 2.14 6.08
-
-
2.31 2.31 2.31 6.57
-
-
35
35
-
-
2.50 2.50 3.50 3.50
-
-
2.81 2.81 3.94 3.94
-
-
25
35
50
-
-
2.31 2.31 3.24 4.63
-
-
2.50 2.50 3.50 5.00
-
-
25
25
35
60
-
-
2.16 2.16 3.02 5.17
-
-
2.33 2.33 3.26 5.59
-
-
25
25
35
71
-
-
2.00 2.00 2.80 5.69
-
-
2.16 2.16 3.03 6.14
-
-
25
25
50
50
-
-
2.08 2.08 4.17 4.17
-
-
2.25 2.25 4.50 4.50
-
-
25
25
50
60
-
-
1.95 1.95 3.91 4.69
-
-
2.11 2.11 4.22 5.06
-
-
25
25
50
71
-
-
1.83 1.83 3.65 5.19
-
-
1.97 1.97 3.95 5.61
-
-
25
25
60
60
-
-
1.84 1.84 4.41 4.41
-
-
1.99 1.99 4.76 4.76
-
-
25
25
60
71
-
-
1.73 1.73 4.14 4.90
-
-
1.86 1.86 4.48 5.30
-
-
25
25
71
71
-
-
1.63 1.63 4.62 4.62
-
-
1.76 1.76 4.99 4.99
-
-
25
35
35
35
-
-
2.40 3.37 3.37 3.37
-
-
2.60 3.63 3.63 3.63
-
-
25
35
35
50
-
-
2.16 3.02 3.02 4.31
-
-
2.33 3.26 3.26 4.66
-
-
25
35
35
60
-
-
2.02 2.82 2.82 4.84
-
-
2.18 3.05 3.05 5.23
-
-
25
35
35
71
-
-
1.88 2.64 2.64 5.35
-
-
2.03 2.85 2.85 5.77
-
-
25
35
50
50
-
-
1.95 2.73 3.91 3.91
-
-
2.11 2.95 4.22 4.22
-
-
25
35
50
60
-
-
1.84 2.57 3.68 4.41
-
-
1.99 2.78 3.97 4.76
-
-
25
35
50
71
-
-
1.73 2.42 3.45 4.90
-
-
1.86 2.61 3.73 5.30
-
-
25
35
60
60
-
-
1.74 2.43 4.17 4.17
-
-
1.88 2.63 4.50 4.50
-
-
25
35
60
71
-
-
1.64 2.29 3.93 4.65
-
-
1.77 2.47 4.24 5.02
-
-
25
50
50
50
-
-
1.79 3.57 3.57 3.57
-
-
1.93 3.86 3.86 3.86
-
-
25
50
50
60
-
-
1.69 3.38 3.38 4.05
-
-
1.82 3.65 3.65 4.38
-
-
25
50
60
60
-
-
1.60 3.21 3.85 3.85
-
-
1.73 3.46 4.15 4.15
-
-
35
35
35
35
-
-
3.13 3.13 3.13 3.13
-
-
3.38 3.38 3.38 3.38
-
-
35
35
35
50
-
-
2.82 2.82 2.82 4.03
-
-
3.05 3.05 3.05 4.35
-
-
35
35
35
60
-
-
2.65 2.65 2.65 4.55
-
-
2.86 2.86 2.86 4.91
-
-
35
35
35
71
-
-
2.49 2.49 2.49 5.04
-
-
2.68 2.68 2.68 5.45
-
-
35
35
50
50
-
-
2.57 2.57 3.68 3.68
-
-
2.78 2.78 3.97 3.97
-
-
35
35
50
60
-
-
2.43 2.43 3.47 4.17
-
-
2.63 2.63 3.75 4.50
-
-
35
35
50
71
-
-
2.29 2.29 3.27 4.65
-
-
2.47 2.47 3.53 5.02
-
-
35
35
60
60
-
-
2.30 2.30 3.95 3.95
-
-
2.49 2.49 4.26 4.26
-
-
35
50
50
50
-
-
2.36 3.38 3.38 3.38
-
-
2.55 3.65 3.65 3.65
-
-
35
50
50
60
-
-
2.24 3.21 3.21 3.85
-
-
2.42 3.46 3.46 4.15
-
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
@amp_aircon |
amp-air-conditioning
34
RAC Systems
SCM125ZM-S
Combination Tables
Operating
Status
230V
5 units
Indoor Unit
Cooling Capacity (kW)
A
B
C
D
E
Heating Capacity (kW)
A
B
C
D
E
F
F
A
20
20
20
20
20
-
2.00 2.00 2.00 2.00 2.00
-
2.70 2.70 2.70 2.70 2.70
B
C
D
E
F
-
20
20
20
20
25
-
2.00 2.00 2.00 2.00 2.50
-
2.57 2.57 2.57 2.57 3.21
-
20
20
20
20
35
-
2.00 2.00 2.00 2.00 3.50
-
2.35 2.35 2.35 2.35 4.11
-
20
20
20
20
50
-
1.92 1.92 1.92 1.92 4.81
-
2.08 2.08 2.08 2.08 5.19
-
20
20
20
20
60
-
1.79 1.79 1.79 1.79 5.36
-
1.93 1.93 1.93 1.93 5.79
-
20
20
20
20
71
-
1.66 1.66 1.66 1.66 5.88
-
1.79 1.79 1.79 1.79 6.35
-
20
20
20
25
25
-
2.00 2.00 2.00 2.50 2.50
-
2.45 2.45 2.45 3.07 3.07
-
20
20
20
25
35
-
2.00 2.00 2.00 2.50 3.50
-
2.25 2.25 2.25 2.81 3.94
-
20
20
20
25
50
-
1.85 1.85 1.85 2.31 4.63
-
2.00 2.00 2.00 2.50 5.00
-
20
20
20
25
60
-
1.72 1.72 1.72 2.16 5.17
-
1.86 1.86 1.86 2.33 5.59
-
20
20
20
25
71
-
1.60 1.60 1.60 2.00 5.69
-
1.73 1.73 1.73 2.16 6.14
-
20
20
20
35
35
-
1.92 1.92 1.92 3.37 3.37
-
2.08 2.08 2.08 3.63 3.63
-
20
20
20
35
50
-
1.72 1.72 1.72 3.02 4.31
-
1.86 1.86 1.86 3.26 4.66
-
20
20
20
35
60
-
1.61 1.61 1.61 2.82 4.84
-
1.74 1.74 1.74 3.05 5.23
-
20
20
20
35
71
-
1.51 1.51 1.51 2.64 5.35
-
1.63 1.63 1.63 2.85 5.77
-
20
20
20
50
50
-
1.56 1.56 1.56 3.91 3.91
-
1.69 1.69 1.69 4.22 4.22
-
20
20
20
50
60
-
1.47 1.47 1.47 3.68 4.41
-
1.59 1.59 1.59 3.97 4.76
-
20
20
20
50
71
-
1.38 1.38 1.38 3.45 4.90
-
1.50 1.50 1.50 4.50 4.50
-
20
20
20
60
60
-
1.39 1.39 1.39 4.17 4.17
-
1.41 1.41 1.41 4.24 5.02
-
20
20
20
60
71
-
1.31 1.31 1.31 3.93 4.65
-
2.35 2.35 2.93 2.93 2.93
-
20
20
25
25
25
-
2.00 2.00 2.50 2.50 2.50
-
2.16 2.16 2.70 2.70 3.78
-
20
20
25
25
35
-
2.00 2.00 2.50 2.50 3.50
-
1.93 1.93 2.41 2.41 4.82
-
20
20
25
25
50
-
1.79 1.79 2.23 2.23 4.46
-
1.80 1.80 2.25 2.25 5.40
-
20
20
25
25
60
-
1.67 1.67 2.08 2.08 5.00
-
1.68 1.68 2.10 2.10 5.95
-
20
20
25
25
71
-
1.55 1.55 1.94 1.94 5.51
-
2.00 2.00 2.50 3.50 3.50
-
20
20
25
35
35
-
1.85 1.85 2.31 3.24 3.24
-
1.80 1.80 2.25 3.15 4.50
-
20
20
25
35
50
-
1.67 1.67 2.08 2.92 4.17
-
1.69 1.69 2.11 2.95 5.06
-
20
20
25
35
60
-
1.56 1.56 1.95 2.73 4.69
-
1.58 1.58 1.97 2.76 5.61
-
20
20
25
35
71
-
1.46 1.46 1.83 2.56 5.19
-
1.64 1.64 2.05 4.09 4.09
-
20
20
25
50
50
-
1.52 1.52 1.89 3.79 3.79
-
1.54 1.54 1.93 3.86 4.63
-
20
20
25
50
60
-
1.43 1.43 1.79 3.57 4.29
-
1.45 1.45 1.81 3.63 5.15
-
20
20
25
50
71
-
1.34 1.34 1.68 3.36 4.77
-
1.46 1.46 1.82 4.38 4.38
-
20
20
25
60
60
-
1.35 1.35 1.69 4.05 4.05
-
1.86 1.86 3.26 3.26 3.26
-
20
20
35
35
35
-
1.72 1.72 3.02 3.02 3.02
-
1.69 1.69 2.95 2.95 4.22
-
20
20
35
35
50
-
1.56 1.56 2.73 2.73 3.91
-
1.59 1.59 2.78 2.78 4.76
-
20
20
35
35
60
-
1.47 1.47 2.57 2.57 4.41
-
1.49 1.49 2.61 2.61 5.30
-
20
20
35
35
71
-
1.38 1.38 2.42 2.42 4.90
-
1.54 1.54 2.70 3.86 3.86
-
20
20
35
50
50
-
1.43 1.43 2.50 3.57 3.57
-
1.46 1.46 2.55 3.65 4.38
-
20
20
35
50
60
-
1.35 1.35 2.36 3.38 4.05
-
1.38 1.38 2.42 4.15 4.15
-
20
20
35
60
60
-
1.28 1.28 2.24 3.85 3.85
-
1.42 1.42 3.55 3.55 3.55
-
20
20
50
50
50
-
1.32 1.32 3.29 3.29 3.29
-
2.25 2.81 2.81 2.81 2.81
-
20
25
25
25
25
-
2.00 2.50 2.50 2.50 2.50
-
2.08 2.60 2.60 2.60 3.63
-
20
25
25
25
35
-
1.92 2.40 2.40 2.40 3.37
-
1.86 2.33 2.33 2.33 4.66
-
20
25
25
25
50
-
1.72 2.16 2.16 2.16 4.31
-
1.74 2.18 2.18 2.18 5.23
-
20
25
25
25
60
-
1.61 2.02 2.02 2.02 4.84
-
1.63 2.03 2.03 2.03 5.77
-
20
25
25
25
71
-
1.51 1.88 1.88 1.88 5.35
-
1.93 2.41 2.41 3.38 3.38
-
20
25
25
35
35
-
1.79 2.23 2.23 3.13 3.13
-
1.74 2.18 2.18 3.05 4.35
-
20
25
25
35
50
-
1.61 2.02 2.02 2.82 4.03
-
1.64 2.05 2.05 2.86 4.91
-
20
25
25
35
60
-
1.52 1.89 1.89 2.65 4.55
-
1.53 1.92 1.92 2.68 5.45
-
20
25
25
35
71
-
1.42 1.78 1.78 2.49 5.04
-
1.59 1.99 1.99 3.97 3.97
-
Continued overleaf.
ampair.co.uk | 01707 378 670 | [email protected]
35
RAC Systems
Power
Supply
RAC Systems
Combination Tables
Operating
Status
SCM125ZM-S Continued
RAC Systems
Power
Supply
230V
5 units
Indoor Unit
Cooling Capacity (kW)
A
B
C
D
E
Heating Capacity (kW)
A
B
C
D
E
F
F
A
20
25
25
50
50
-
1.47 1.84 1.84 3.68 3.68
-
1.50 1.88 1.88 3.75 4.50
B
C
D
E
F
-
20
25
25
50
60
-
1.39 1.74 1.74 3.47 4.17
-
1.41 1.77 1.77 3.53 5.02
-
20
25
25
50
71
-
1.31 1.64 1.64 3.27 4.65
-
1.42 1.78 1.78 4.26 4.26
-
20
25
25
60
60
-
1.32 1.64 1.64 3.95 3.95
-
1.80 2.25 3.15 3.15 3.15
-
20
25
35
35
35
-
1.67 2.08 2.92 2.92 2.92
-
1.64 2.05 2.86 2.86 4.09
-
20
25
35
35
50
-
1.52 1.89 2.65 2.65 3.79
-
1.54 1.93 2.70 2.70 4.63
-
20
25
35
35
60
-
1.43 1.79 2.50 2.50 4.29
-
1.45 1.81 2.54 2.54 5.15
-
20
25
35
35
71
-
1.34 1.68 2.35 2.35 4.77
-
1.50 1.88 2.63 3.75 3.75
-
20
25
35
50
50
-
1.39 1.74 2.43 3.47 3.47
-
1.42 1.78 2.49 3.55 4.26
-
20
25
35
50
60
-
1.32 1.64 2.30 3.29 3.95
-
1.38 1.73 3.46 3.46 3.46
-
20
25
50
50
50
-
1.28 1.60 3.21 3.21 3.21
-
1.69 2.95 2.95 2.95 2.95
-
20
35
35
35
35
-
1.56 2.73 2.73 2.73 2.73
-
1.54 2.70 2.70 2.70 3.86
-
20
35
35
35
50
-
1.43 2.50 2.50 2.50 3.57
-
1.46 2.55 2.55 2.55 4.38
-
20
35
35
35
60
-
1.35 2.36 2.36 2.36 4.05
-
1.42 2.49 2.49 3.55 3.55
-
20
35
35
50
50
-
1.32 2.30 2.30 3.29 3.29
-
2.70 2.70 2.70 2.70 2.70
-
25
25
25
25
25
-
2.50 2.50 2.50 2.50 2.50
-
2.50 2.50 2.50 2.50 3.50
-
25
25
25
25
35
-
2.31 2.31 2.31 2.31 3.24
-
2.25 2.25 2.25 2.25 4.50
-
25
25
25
25
50
-
2.08 2.08 2.08 2.08 4.17
-
2.11 2.11 2.11 2.11 5.06
-
25
25
25
25
60
-
1.95 1.95 1.95 1.95 4.69
-
1.97 1.97 1.97 1.97 5.61
-
25
25
25
35
35
-
2.16 2.16 2.16 3.02 3.02
-
2.33 2.33 2.33 3.26 3.26
-
25
25
25
35
50
-
1.95 1.95 1.95 2.73 3.91
-
2.11 2.11 2.11 2.95 4.22
-
25
25
25
35
60
-
1.84 1.84 1.84 2.57 4.41
-
1.99 1.99 1.99 2.78 4.76
-
25
25
25
35
71
-
1.73 1.73 1.73 2.42 4.90
-
1.86 1.86 1.86 2.61 5.30
-
25
25
25
50
50
-
1.79 1.79 1.79 3.57 3.57
-
1.93 1.93 1.93 3.86 3.86
-
25
25
25
50
60
-
1.69 1.69 1.69 3.38 4.05
-
1.82 1.82 1.82 3.65 4.38
-
25
25
25
60
60
-
1.60 1.60 1.60 3.85 3.85
-
1.73 1.73 1.73 4.15 4.15
-
25
25
35
35
35
-
2.02 2.02 2.82 2.82 2.82
-
2.18 2.18 3.05 3.05 3.05
-
25
25
35
35
50
-
1.84 1.84 2.57 2.57 3.68
-
1.99 1.99 2.78 2.78 3.97
-
25
25
35
35
60
-
1.74 1.74 2.43 2.43 4.17
-
1.88 1.88 2.63 2.63 4.50
-
25
25
35
35
71
-
1.64 1.64 2.29 2.29 4.65
-
1.77 1.77 2.47 2.47 5.02
-
25
25
35
50
50
-
1.69 1.69 2.36 3.38 3.38
-
1.82 1.82 2.55 3.65 3.65
-
25
25
35
50
60
-
1.60 1.60 2.24 3.21 3.85
-
1.73 1.73 2.42 3.46 4.15
-
25
35
35
35
35
-
1.89 2.65 2.65 2.65 2.65
-
2.05 2.86 2.86 2.86 2.86
-
25
35
35
35
50
-
1.74 2.43 2.43 2.43 3.47
-
1.88 2.63 2.63 2.63 3.75
-
25
35
35
35
60
-
1.64 2.30 2.30 2.30 3.95
-
1.78 2.49 2.49 2.49 4.26
-
25
35
35
50
50
-
1.60 2.24 2.24 3.21 3.21
-
1.73 2.42 2.42 3.46 3.46
-
35
35
35
35
35
-
2.50 2.50 2.50 2.50 2.50
-
2.70 2.70 2.70 2.70 2.70
-
35
35
35
35
50
-
2.30 2.30 2.30 2.30 3.29
-
2.49 2.49 2.49 2.49 3.55
-
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
@amp_aircon |
amp-air-conditioning
36
RAC Systems
SCM125ZM-S
Combination Tables
Operating
Status
230V
6 units
Indoor Unit
Cooling Capacity (kW)
A
B
C
D
E
Heating Capacity (kW)
A
B
C
D
E
F
F
A
20
20
20
20
20
20
2.00 2.00 2.00 2.00 2.00 2.00 2.25 2.25 2.25 2.25 2.25 2.25
B
C
D
E
F
20
20
20
20
20
25
2.00 2.00 2.00 2.00 2.00 2.50 2.16 2.16 2.16 2.16 2.16 2.70
20
20
20
20
20
35
1.85 1.85 1.85 1.85 1.85 3.24 2.00 2.00 2.00 2.00 2.00 3.50
20
20
20
20
20
50
1.67 1.67 1.67 1.67 1.67 4.17 1.80 1.80 1.80 1.80 1.80 4.50
20
20
20
20
20
60
1.56 1.56 1.56 1.56 1.56 4.69 1.69 1.69 1.69 1.69 1.69 5.06
20
20
20
20
20
71
1.46 1.46 1.46 1.46 1.46 5.19 1.58 1.58 1.58 1.58 1.58 5.61
20
20
20
20
25
25
1.92 1.92 1.92 1.92 2.40 2.40 2.08 2.08 2.08 2.08 2.60 2.60
20
20
20
20
25
35
1.79 1.79 1.79 1.79 2.23 3.13 1.93 1.93 1.93 1.93 2.41 3.38
20
20
20
20
25
50
1.61 1.61 1.61 1.61 2.02 4.03 1.74 1.74 1.74 1.74 2.18 4.35
20
20
20
20
25
60
1.52 1.52 1.52 1.52 1.89 4.55 1.64 1.64 1.64 1.64 2.05 4.91
20
20
20
20
35
35
1.67 1.67 1.67 1.67 2.92 2.92 1.53 1.53 1.53 1.53 1.92 5.45
20
20
20
20
35
50
1.52 1.52 1.52 1.52 2.65 3.79 1.80 1.80 1.80 1.80 3.15 3.15
20
20
20
20
35
60
1.43 1.43 1.43 1.43 2.50 4.29 1.64 1.64 1.64 1.64 2.86 4.09
20
20
20
20
35
71
1.34 1.34 1.34 1.34 2.35 4.77 1.54 1.54 1.54 1.54 2.70 4.63
20
20
20
20
50
50
1.39 1.39 1.39 1.39 3.47 3.47 1.45 1.45 1.45 1.45 2.54 5.15
20
20
20
20
50
60
1.32 1.32 1.32 1.32 3.29 3.95 1.50 1.50 1.50 1.50 3.75 3.75
20
20
20
25
25
25
1.85 1.85 1.85 2.31 2.31 2.31 1.42 1.42 1.42 1.42 3.55 4.26
20
20
20
25
25
35
1.72 1.72 1.72 2.16 2.16 3.02 2.00 2.00 2.00 2.50 2.50 2.50
20
20
20
25
25
50
1.56 1.56 1.56 1.95 1.95 3.91 1.86 1.86 1.86 2.33 2.33 3.26
20
20
20
25
25
60
1.47 1.47 1.47 1.84 1.84 4.41 1.69 1.69 1.69 2.11 2.11 4.22
20
20
20
25
25
71
1.38 1.38 1.38 1.73 1.73 4.90 1.59 1.59 1.59 1.99 1.99 4.76
20
20
20
25
35
35
1.61 1.61 1.61 2.02 2.82 2.82 1.49 1.49 1.49 1.86 1.86 5.30
20
20
20
25
35
50
1.47 1.47 1.47 1.84 2.57 3.68 1.74 1.74 1.74 2.18 3.05 3.05
20
20
20
25
35
60
1.39 1.39 1.39 1.74 2.43 4.17 1.59 1.59 1.59 1.99 2.78 3.97
20
20
20
25
35
71
1.31 1.31 1.31 1.64 2.29 4.65 1.50 1.50 1.50 1.88 2.63 4.50
20
20
20
25
50
50
1.35 1.35 1.35 1.69 3.38 3.38 1.46 1.46 1.46 1.82 3.65 3.65
20
20
20
25
50
60
1.28 1.28 1.28 1.60 3.21 3.85 1.38 1.38 1.38 1.73 3.46 4.15
20
20
20
35
35
35
1.52 1.52 1.52 2.65 2.65 2.65 1.64 1.64 1.64 2.86 2.86 2.86
20
20
20
35
35
50
1.39 1.39 1.39 2.43 2.43 3.47 1.50 1.50 1.50 2.63 2.63 3.75
20
20
20
35
35
60
1.32 1.32 1.32 2.30 2.30 3.95 1.42 1.42 1.42 2.49 2.49 4.26
20
20
20
35
50
50
1.28 1.28 1.28 2.24 3.21 3.21 1.38 1.38 1.38 2.42 3.46 3.46
20
20
25
25
25
25
1.79 1.79 2.23 2.23 2.23 2.23 1.93 1.93 2.41 2.41 2.41 2.41
20
20
25
25
25
35
1.67 1.67 2.08 2.08 2.08 2.92 1.80 1.80 2.25 2.25 2.25 3.15
20
20
25
25
25
50
1.52 1.52 1.89 1.89 1.89 3.79 1.64 1.64 2.05 2.05 2.05 4.09
20
20
25
25
25
60
1.43 1.43 1.79 1.79 1.79 4.29 1.54 1.54 1.93 1.93 1.93 4.63
20
20
25
25
25
71
1.34 1.34 1.68 1.68 1.68 4.77 1.45 1.45 1.81 1.81 1.81 5.15
20
20
25
25
35
35
1.56 1.56 1.95 1.95 2.73 2.73 1.69 1.69 2.11 2.11 2.95 2.95
20
20
25
25
35
50
1.43 1.43 1.79 1.79 2.50 3.57 1.54 1.54 1.93 1.93 2.70 3.86
20
20
25
25
35
60
1.35 1.35 1.69 1.69 2.36 4.05 1.46 1.46 1.82 1.82 2.55 4.38
20
20
25
25
50
50
1.32 1.32 1.64 1.64 3.29 3.29 1.42 1.42 1.78 1.78 3.55 3.55
20
20
25
35
35
35
1.47 1.47 1.84 2.57 2.57 2.57 1.59 1.59 1.99 2.78 2.78 2.78
20
20
25
35
35
50
1.35 1.35 1.69 2.36 2.36 3.38 1.46 1.46 1.82 2.55 2.55 3.65
20
20
25
35
35
60
1.28 1.28 1.60 2.24 2.24 3.85 1.38 1.38 1.73 2.42 2.42 4.15
20
20
35
35
35
35
1.39 1.39 2.43 2.43 2.43 2.43 1.50 1.50 2.63 2.63 2.63 2.63
20
20
35
35
35
50
1.28 1.28 2.24 2.24 2.24 3.21 1.38 1.38 2.42 2.42 2.42 3.46
20
25
25
25
25
25
1.72 2.16 2.16 2.16 2.16 2.16 1.86 2.33 2.33 2.33 2.33 2.33
20
25
25
25
25
35
1.61 2.02 2.02 2.02 2.02 2.82 1.74 2.18 2.18 2.18 2.18 3.05
20
25
25
25
25
50
1.47 1.84 1.84 1.84 1.84 3.68 1.59 1.99 1.99 1.99 1.99 3.97
20
25
25
25
25
60
1.39 1.74 1.74 1.74 1.74 4.17 1.50 1.88 1.88 1.88 1.88 4.50
20
25
25
25
25
71
1.31 1.64 1.64 1.64 1.64 4.65 1.41 1.77 1.77 1.77 1.77 5.02
Continued overleaf.
ampair.co.uk | 01707 378 670 | [email protected]
37
RAC Systems
Power
Supply
RAC Systems
Combination Tables
Operating
Status
SCM125ZM-S
RAC Systems
Power
Supply
230V
6 units
Indoor Unit
Cooling Capacity (kW)
A
B
C
D
E
Heating Capacity (kW)
A
B
C
D
E
F
F
A
20
25
25
25
35
35
1.52 1.89 1.89 1.89 2.65 2.65 1.64 2.05 2.05 2.05 2.86 2.86
B
C
D
E
F
20
25
25
25
35
50
1.39 1.74 1.74 1.74 2.43 3.47 1.50 1.88 1.88 1.88 2.63 3.75
20
25
25
25
35
60
1.32 1.64 1.64 1.64 2.30 3.95 1.42 1.78 1.78 1.78 2.49 4.26
20
25
25
25
50
50
1.28 1.60 1.60 1.60 3.21 3.21 1.38 1.73 1.73 1.73 3.46 3.46
20
25
25
35
35
35
1.43 1.79 1.79 2.50 2.50 2.50 1.54 1.93 1.93 2.70 2.70 2.70
20
25
25
35
35
50
1.32 1.64 1.64 2.30 2.30 3.29 1.42 1.78 1.78 2.49 2.49 3.55
20
25
35
35
35
35
1.35 1.69 2.36 2.36 2.36 2.36 1.46 1.82 2.55 2.55 2.55 2.55
20
35
35
35
35
35
1.28 2.24 2.24 2.24 2.24 2.24 1.38 2.42 2.42 2.42 2.42 2.42
25
25
25
25
25
25
2.16 2.16 2.16 2.16 2.16 2.16 2.33 2.33 2.33 2.33 2.33 2.33
25
25
25
25
25
35
1.95 1.95 1.95 1.95 1.95 2.73 2.11 2.11 2.11 2.11 2.11 2.95
25
25
25
25
25
50
1.79 1.79 1.79 1.79 1.79 3.57 1.93 1.93 1.93 1.93 1.93 3.86
25
25
25
25
25
60
1.69 1.69 1.69 1.69 1.69 4.05 1.82 1.82 1.82 1.82 1.82 4.38
25
25
25
25
35
35
1.84 1.84 1.84 1.84 2.57 2.57 1.99 1.99 1.99 1.99 2.78 2.78
25
25
25
25
35
50
1.69 1.69 1.69 1.69 2.36 3.38 1.82 1.82 1.82 1.82 2.55 3.65
25
25
25
25
35
60
1.60 1.60 1.60 1.60 2.24 3.85 1.73 1.73 1.73 1.73 2.42 4.15
25
25
25
35
35
35
1.74 1.74 1.74 2.43 2.43 2.43 1.88 1.88 1.88 2.63 2.63 2.63
25
25
25
35
35
50
1.60 1.60 1.60 2.24 2.24 3.21 1.73 1.73 1.73 2.42 2.42 3.46
25
25
35
35
35
35
1.64 1.64 2.30 2.30 2.30 2.30 1.78 1.78 2.49 2.49 2.49 2.49
The above capacities exclude SRK ZMX-S unit, although these units can be used capacities will differ, contact AMP for details.
@amp_aircon |
amp-air-conditioning
38
PAC Systems
PAC Systems
MHI installation at London Underground Depot courtesy of MasterCool Air Conditioning
ampair.co.uk | 01707 378 670 | [email protected]
39
PAC Systems
Range Overview
»» With 7 different indoor unit styles
available, combined with 3 ranges of
inverter driven condensing units, MHI
have the solution for any application
»» The hyper inverter range offer industry
leading efficiencies and pipework runs of
up to 100m
»» Complemented by a wide range of control
options, including hard wired and infrared
and the ability to integrate these split
systems onto centralised controllers and
BMS systems
»» Available in single, twin, triple and quad
system combinations
»» R22 & R407C replacement technology
available on all systems
Nominal Cooling
SRK ZR
Wall
Mounted
2.5
3.5
4.0
5.0
6.0
12.5
14.0
1Ph 49
3Ph 50
1Ph 49
3Ph 50
1Ph 49
3Ph 50
1Ph 52
3Ph 54
1Ph 53
3Ph 54
1Ph 53
3Ph 54
1Ph 57
3Ph 58
1Ph 61
3Ph 62
1Ph 57
3Ph 58
1Ph 61
3Ph 62
MI
1Ph 65
3Ph 66
1Ph 65
3Ph 66
1Ph 65
3Ph 66
HI
1Ph 62
1Ph 68
3Ph 70
1Ph 69
3Ph 70
1Ph 69
3Ph 70
SI
1Ph 72
1Ph 72
1Ph 73
3Ph 74
1Ph 73
3Ph 74
1Ph 73
3Ph 74
1Ph 76
3Ph 78
1Ph 77
3Ph 78
1Ph 77
3Ph 78
1Ph 81
3Ph 82
1Ph 81
3Ph 82
1Ph 81
3Ph 82
1Ph 83
3Ph 85
1Ph 84
3Ph 85
1Ph 84
3Ph 85
SI
7.1
10.0
1Ph 41
1Ph 42
1Ph 48
1Ph 48
20.0
25.0
3Ph 67
3Ph 67
MI
HI
FDTC VF
Compact
Cassette
SI
MI
HI
1Ph 45
1Ph 45
1Ph 45
1Ph 46
1Ph 46
FDT VF
4 Way
Cassette
SI
MI
FDEN VF
Ceiling
Suspended
FDU VF
High Static
Ducted
FDUM VF
Standard
Ducted
HI
1Ph 51
1Ph 51
1Ph 51
SI
1Ph 52
1Ph 56
MI
HI
1Ph 59
1Ph 59
1Ph 59
SI
1Ph 60
1Ph 64
MI
HI
SI
FDF VD
Floor
Standing
PAC Systems
AMP can offer an extensive range of MHI packaged split systems which utilises the latest in
technology to provide industry leading performance and efficiencies.
1Ph 75
1Ph 75
1Ph 75
1Ph 76
1Ph 80
MI
HI
1Ph 83
SI - Standard Inverter | MI - Micro Inverter | HI - Hyper Inverter
@amp_aircon |
amp-air-conditioning
1Ph 56
1Ph 57
3Ph 58
1Ph 60
3Ph 62
1Ph 64
1Ph 80
Page numbers shown in italics
40
PAC Systems
Wall Mounted Standard Inverter
»»
»»
»»
Indoor Unit
SRK71ZM-S
Infrared Remote Controller
Included
Outdoor Unit
PERFORMANCE
»»
technology
Selected outdoor units with Blue
Fin protection
Compact design of outdoor units
Infrared controller as standard
including 7-day time clock
Available in twin systems (see page
86 for details)
FDC71VNP
kW
UK Cooling (Total - Sensible)
kW
6.8 - 4.9
Nominal Heating (Range)
kW
7.1 (1.0 - 7.1)
UK Heating
kW
Wired remote controller
with 7-day time clock
(requires SC-BIKN-E)
£63
RC-EX1A
Premium wired touch
screen remote controller
with 7-day time clock
(requires SC-BIKN-E)
£123
SC-ADNA-E
Superlink network
adapter for connection
to central controllers
£106
CNT connector for
PCZ006A043 remote on/off, run/
fault etc.
£10
EFFICIENCY
RC-E5
Gas
Standard Inverter VNP
1/4"
1/2"
71
1/4"
5/8"
71
3/8"
1/2"
71
3/8"
5/8"
71-100
Subject to the pipe sizes used and selected outdoor unit
additional pipe work and capacity, limitations may apply.
Contact AMP for details.
46 to -15
°C
20 to -15
318 - 1098 - 248
Outdoor Unit Dimensions (H-W-D)
mm
640 - 800 (+71) - 290
kg
16 - 45
Indoor Unit Airflow Rate (L-M-H)
l/s
233 - 258 - 325
Static Pressure
Pa
0
Indoor Sound Pressure (Ul-L-M-H)
DB(A)
26 - 39 - 45 - 49
Outdoor Sound Pressure (Cool-Heat)
DB(A)
54 - 54
Pipe Sizes (Gas - Liquid) *
in
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
Pre-Charged for
m
REFRIGERANT & PIPEWORK
Liquid
°C
mm
Operating Range Heat
Weight (Indoor - Outdoor)
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
15
1.6kg - 20g/m
Charge R410A (Factory - Additional)
Power Supply (Outdoor)
mm
no - VP16 (14id 16od)
V-Ph-Hz
230 - 1 - 50
3 core + E
Interconnecting Cables
POWER
Allowable
Outdoors
Operating Range Cool
Indoor Unit Dimensions (H-W-D)
See page 173 for other controls & accessories.
Existing
Pipe Sizes
B/A
Energy Label (Cooling / Heating)
AMBIENT
RANGE
£151
PHYSICAL
SC-BIKN-E
3.01 - 3.78
Eer - Cop (Cool - Heat)
AIRFLOW
Description
Adapter for wired
controller etc
A++ / A+
Energy Eff. Class (Cooling / Heating)
SOUND
Part No.
List
Price
5.2
6.60 - 4.47
SEER - SCOP (Cool - Heat)
Controllers
7.1 (1.4 - 7.1)
Nominal Cooling
A
10.9 - 8.8
kW
2.36 - 1.88
Start - Max Run Current
A
5.0 - 14.5
Suggested Fuse Size
A
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
16
£644
Indoor Unit
Outdoor Unit
£1,329
Retail Price
£1,973
ampair.co.uk | 01707 378 670 | [email protected]
41
PAC Systems
»» Suitable for replacement
PAC Systems
Wall Mounted Standard Inverter
Indoor Unit
SRK100ZR-S
Infrared Remote Controller
Included
FDC100VNP
kW
UK Cooling (Total - Sensible)
kW
9.38 - 7.16
Nominal Heating (Range)
kW
11.2 (3.2 - 11.5)
UK Heating
kW
EFFICIENCY
7.30
6.60 - 4.40
A++ / A+
Energy Eff. Class (Cooling / Heating)
3.24 - 3.41
Eer - Cop (Cool - Heat)
A/B
Energy Label (Cooling / Heating)
°C
46 to -15
20 to -15
mm
339 - 1197 - 262
Outdoor Unit Dimensions (H-W-D)
mm
845 - 970 - 370
kg
16.5 - 70
Indoor Unit Airflow Rate (L-M-H)
l/s
226 - 318 - 386 - 458
Static Pressure
Pa
0
Indoor Sound Pressure (Ul-L-M-H)
DB(A)
30 - 40 - 45 - 48
Outdoor Sound Pressure (Cool-Heat)
DB(A)
57 - 61
Pipe Sizes (Gas - Liquid) *
in
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
Pre-Charged for
m
REFRIGERANT & PIPEWORK
PHYSICAL
°C
Indoor Unit Dimensions (H-W-D)
AIRFLOW
Operating Range Cool
SOUND
AMBIENT
RANGE
10.0 (2.4 - 10.5)
Nominal Cooling
SEER - SCOP (Cool - Heat)
Operating Range Heat
Weight (Indoor - Outdoor)
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Mm
No - VP16 (14id 16od)
V-Ph-Hz
230 - 1 - 50
A
13.6 - 14.4
3 core + E
Interconnecting Cables
Running Current (Cool - Heat)
15
2.55kg - 60g/m
Charge R410A (Factory - Additional)
Power Supply (Outdoor)
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
kW
3.09 - 3.28
Start - Max Run Current
A
14.4 - 21
Suggested Fuse Size
A
Power Cons. (Cool - Heat)
25
£806
Indoor Unit
Outdoor Unit
£1,536
Retail Price
£2,342
@amp_aircon |
amp-air-conditioning
42
PAC Systems
WARmER WiNTERs
Perfect
coolER summERs
The NEW highly efficient...
The new KXZ VRF system delivers high performance cooling and
heating for all commercial applications with a compact system
offering the highest level of design flexibility.
Also with Variable Temperature and Capacity Control technology
, the new KXZ can also increase energy savings of up to
34%* offering one of the best efficiency ratings in the market.
See
VRF Systems on page 93
mitsubishikxz.eu
*34% energy savings are based on comparison with a KXZ standard model with VTcc vs. a KXZ standard model both under partial load condition.
KXZ Advert - Warmer Cooler 210x297 1-9-14.indd 1
ampair.co.uk | 01707 378 670 | [email protected]
43
01/09/2014 12:53
PAC Systems
PAC Systems
FDTC Compact 4 Way Cassettes
FDTC Indoor Unit
»»
»»
»»
»»
»»
»»
SRC50ZMX-S Outdoor Unit
High SEERs & SCOPs
Individual flap control
Suitable for replacement technology
Selected outdoor units with Blue Fin protection
Indoor units with branch duct facility
Indoor lift pump fitted as standard, 600mm from
ceiling tile
Compatible Accessories
»» Available with a range of hard wired and infrared
control options
»» Can connect to centralised controller via superlink
network (SC-ADNA-E adapter required)
»» Available in twin, triple and quad systems (see
page 86 for details)
Existing Pipe Sizes
Part No.
Description
List
Price
RC-E5*
Wired remote controller with 7-day
time clock (requires SC-BIKN-E)
£63
RC-EX1A
Premium wired touch screen
remote controller with 7-day time
clock (requires SC-BIKN-E)
£123
RCH-E3
Simplified wired remote controller
£106
RCN-TC24W-ER
Infrared remote controller kit
£132
SC-ADNA-E
Superlink network adapter for
connection to central controllers
£106
PCZ006A043
CNT connector for remote on/off,
run/fault etc.
£10
FM-MRFVF
CNT indoor run fault adapter
(volt free)
£110
Allowable Outdoors
Liquid
Gas
Hyper Inverter ZMX-S
1/4"
1/2"
40-50-60
3/8"
1/2"
40-50-60
Subject to the pipe sizes used and selected outdoor unit additional pipe work and
capacity, limitations may apply.
Contact AMP for details.
Replacement
Technology
Compatible
Connect to
pre-installed
pipework
*Included in system price as standard. See page 173 for other controls and
accessories.
@amp_aircon |
amp-air-conditioning
44
PAC Systems
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
FDTC40VF
TC-PSA-25W-E
RC-E5
RC-E5
RC-E5
SRC25ZMX-S
SRC35ZMX-S
SRC40ZMX-S
4.0 (1.1 - 4.7)
kW
2.5 (0.9 - 3.2)
3.6 (0.9 - 4.1)
UK Cooling (Total - Sensible)
kW
2.4 - 2.2
3.4 - 3.1
3.8 - 3.2
Nominal Heating (Range)
kW
3.4 (0.9 - 4.7)
4.2 (0.9 - 5.1)
4.5 (0.6 - 5.4)
UK Heating
kW
2.5
3.1
3.7
6.10 - 4.13
6.12 - 4.15
6.53 - 3.96
A++ / A+
A++ / A+
A++ / A
4.25 - 4.11
3.36 - 3.66
3.85 - 4.09
A/A
A/A
A/A
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Energy Label (Cool / Heat)
AMBIENT
RANGE
FDTC35VF
TC-PSA-25W-E
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
°C
46 to -15
Operating Range Heat
°C
21 to -15
mm
248 (35) - 570 (700) 570 (700)
248 (35) - 570 (700) 570 (700)
248 (35) - 570 (700) 570 (700)
Outdoor Unit Dim. (H-W-D)
640 - 800 (+71) - 290
595 - 780 (+62) - 290
595 - 780 (+62) - 290
kg
15.0 (3.5) - 35
15.0 (3.5) - 35
15.0 (3.5) - 45
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
120 - 140 - 160 - 180
130 - 150 - 170 - 190
133 - 150 - 191 - 225
Static Pressure
Pa
0
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
30 - 33 - 38 - 39
32 - 35 - 42 - 43
32 - 36 - 42 - 47
Outdoor Sound Pressure (Cool-Heat)
dB(A)
47 - 47
50 - 50
50 - 50
Pipe Sizes (Gas - Liquid)
in
3/8" - 1/4"
3/8" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
15 - 10
15 - 10
30 - 20
Pre-Charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
1.2kg - n/a
1.2kg - n/a
1.5kg - 20g/m
No
No
Yes
REFRIGERANT & PIPEWORK
mm
Weight (Indoor (Grille) - Outdoor)
AIRFLOW
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
PHYSICAL
FDTC25VF
TC-PSA-25W-E
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
2.9 - 4.0
4.7 - 5.1
4.6 - 4.9
V-Ph-Hz
POWER
Interconnecting Cables
Running Current (Cool - Heat)
Yes* - VP20 (20id 26od)
mm
kW
0.60 - 0.84
1.07 - 1.16
1.04 - 1.10
Start - Max Run Current
A
4.0 - 9.0
5.3 - 9.0
5.0 - 12.0
Suggested Fuse Size
A
13
13
16
Indoor Unit
£523
£530
£548
£140
Power Cons. (Cool - Heat)
Grille
£140
£140
Remote Controller
£63
£63
£63
Outdoor Unit
£556
£620
£880
Retail Price
£1,282
£1,353
£1,631
*Lift pump as standard, 600mm from the underside of the ceiling tile | Knock out for branch duct 100 x 100 | Maximum indoor airflow/sound pressure level in either cool or
heat shown.
ampair.co.uk | 01707 378 670 | [email protected]
45
PAC Systems
FDTC Compact 4 Way Cassette Hyper Inverter
PAC Systems
FDTC Compact 4 Way Cassette Hyper Inverter
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
EFFICIENCY
RC-E5
SRC60ZMX-S
5.6 (1.1 - 6.3)
5.0 (1.1 - 5.6)
UK Cooling (Total - Sensible)
kW
4.8 - 3.6
5.4 - 3.8
Nominal Heating (Range)
kW
5.4 (0.6 - 6.3)
6.7 (0.6 - 6.7)
UK Heating
kW
4.5
5.6
6.01 - 3.85
5.76 - 3.80
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
RC-E5
SRC50ZMX-S
kW
Energy Label (Cool / Heat)
A+ / A
A+ / A
3.21 - 3.72
2.81 - 3.24
A/A
C/C
Operating Range Cool
°C
46 to -15
Operating Range Heat
°C
21 to -15
mm
248 (35) - 570 (700) - 570 (700)
248 (35) - 570 (700) - 570 (700)
Outdoor Unit Dim. (H-W-D)
640 - 800 (+71) - 290
640 - 800 (+71) - 290
kg
15.0 (3.5) - 45
15.0 (3.5) - 45
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
133 - 150 - 191 - 225
133 - 150 - 191 - 225
Static Pressure
Pa
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
32 - 36 - 42 - 47
32 - 39 - 46 - 47
Outdoor Sound Pressure (Cool-Heat)
dB(A)
54 - 50
54 - 54
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
Pre-Charged for
m
15
15
Charge R410A (Factory - Additional)
kg
1.5kg - 20g/m
1.5kg - 20g/m
Yes
Yes
REFRIGERANT & PIPEWORK
mm
Weight (Indoor (Grille) - Outdoor)
AIRFLOW
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
PHYSICAL
FDTC60VF
TC-PSA-25W-E
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Yes* - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
6.9 - 6.4
8.3 - 8.7
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
FDTC50VF
TC-PSA-25W-E
kW
1.56 - 1.45
1.99 - 2.07
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20
20
Indoor Unit
£562
£616
£140
Power Cons. (Cool - Heat)
Grille
£140
Remote Controller
£63
£63
Outdoor Unit
£973
£1,102
Retail Price
£1,738
£1,921
@amp_aircon |
amp-air-conditioning
46
PAC Systems
PAC Systems
FDT 4 Way Cassettes
FDT Indoor Unit
FDC140VN Outdoor Unit
»» Available with a range of outdoors, offering high
»»
»»
»»
»»
»»
SEERs and SCOPs
Individual flap control
Extended pipe runs of up to 100m
Suitable for replacement technology (see below)
Selected outdoor units with Blue Fin protection
Indoor units with branch duct & fresh air intake
Compatible Accessories
Part No.
Description
RC-E5*
Wired remote controller with 7-day
time clock (requires SC-BIKN-E)
RC-EX1A
Premium wired touch screen
remote controller with 7-day time
clock (requires SC-BIKN-E)
RCH-E3
Simplified wired remote controller
List
Price
»» Lift pump fitted as standard 700mm from ceiling tile
»» Available with a range of hard-wired & infrared
controls
»» Can connect to centralised controller via superlink
network (SC-ADNA-E adapter required)
»» Available in twin, triple and quad systems (see
page 86 for details)
Existing
Pipe Sizes
Liquid Gas
£63
Allowable Outdoors
Standard
Inverter VNP
Micro Inverter
VN & VS
Hyper Inverter
ZMX-S, VNX
& VSX
1/4"
1/2"
71
40-50-60
£123
1/4"
5/8"
71
71-100-125-140
3/8"
1/2"
71
£106
3/8"
5/8"
71-100
3/8"
3/4"
1/2"
5/8"
1/2"
3/4"
RCN-T36W-E
Infrared remote controller kit
£132
SC-ADNA-E
Superlink network adapter for
connection to central controllers
£106
PCZ006A043
CNT connector for remote on/off,
run/fault etc.
£10
FM-MRFVF
CNT indoor run fault adapter
(volt free)
£110
100
40-50-60-71
100-125-140
71-100-125-140
100-125-140
100-125-140
100-125-140
71-100-125-140
100-125-140
100-125-140
Subject to the pipe sizes used and selected outdoor unit additional pipe work and
capacity, limitations may apply.
Contact AMP for details.
*Included in system price as standard. See page 173 for other controls and
accessories.
ampair.co.uk | 01707 378 670 | [email protected]
47
PAC Systems
FDT 4 Way Cassette Standard Inverter
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
EFFICIENCY
RC-E5
FDC100VNP
10 (2.8 - 11.2)
7.1 (1.4 - 7.1)
UK Cooling (Total - Sensible)
kW
6.9 - 6.0
9.38 - 8.32
Nominal Heating (Range)
kW
7.1 (1.0 - 7.1)
11.2 (2.5 - 12.5)
UK Heating
kW
5.2
7.30
6.14 - 4.27
6.78 - 4.52
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
RC-E5
FDC71VNP
kW
Energy Label (Cool / Heat)
A++ / A+
A++ / A+
2.84 - 3.74
3.62 - 4.52
C/A
A/A
Operating Range Cool
°C
46 to -15
Operating Range Heat
°C
20 to -15
mm
246 (35) - 840 (950) - 840 (950)
298 (35) - 840 (950) - 840 (950)
Outdoor Unit Dim. (H-W-D)
845 - 970 - 370
640 - 800 (+71) - 290
kg
24 .0 (5.5) - 45
27.0 (5.5) - 70
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
283 - 317 - 350 - 467
333 - 400 - 450 - 617
Static Pressure
Pa
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
31 - 33 - 35 - 46
35 - 37 - 40 - 51
Outdoor Sound Pressure (Cool-Heat)
dB(A)
54 - 54
57 - 61
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
REFRIGERANT & PIPEWORK
mm
Weight (Indoor (Grille) - Outdoor)
AIRFLOW
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
PHYSICAL
FDT100VF2
T-PSA-3BW-E
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Pre-Charged for
m
15
15
Charge R410A (Factory - Additional)
kg
1.6kg - 20g/m
2.55kg - 60g/m
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Yes** - VP25 (25id 32od)
mm
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
11.10 - 8.50
12.10 - 12.50
kW
2.50 - 1.90
2.76 - 2.84
Start - Max Run Current
A
5.0 - 14.5
21.0
Suggested Fuse Size
A
16
25
Indoor Unit
£675
£900
Grille
£160
£160
Remote Controller
£63
£63
Outdoor Unit
£1,329
£1,536
Retail Price
£2,227
£2,659
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
FDT71VF1
T-PSA-3BW-E
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
* Outdoor includes 3/8" & 5/8" reducers for indoor unit connection | **Lift pump as standard, 700mm from the underside of the ceiling tile | Knock out for branch duct 100mm
x 100mm | Knock out for fresh air intake 65mm x 112mm.
@amp_aircon |
amp-air-conditioning
48
PAC Systems
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
FDT125VF
FDT140VF
T-PSA-3BW-E
T-PSA-3BW-E
RC-E5
RC-E5
RC-E5
FDC100VN
FDC125VN
FDC140VN
14.0 (5.0 - 14.5)
Nominal Cooling (Range)
kW
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
9.4 - 7.1
11.8 - 8.5
12.7 - 9.4
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
5.61 - 3.92
n/a
n/a
A+ / A
n/a
n/a
3.62 - 4.09
3.09 - 3.71
2.81 - 3.50
A/A
B/A
C/B
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Energy Label (Cool / Heat)
Operating Range Cool
°C
43 to -15
Operating Range Heat
°C
20 to -20
298 (35) - 840 (950) 840 (950)
298 (35) - 840 (950) 840 (950)
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
27.0 (5.5) - 81.0
27.0 (5.5) - 81.0
27.0 (5.5) - 81.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
333 - 400 - 450 - 617
383 - 450 - 500 - 617
383 - 450 - 500 - 617
Static Pressure
Pa
0
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
35- 37 - 40 - 51
37 - 40 - 42 - 51
38 - 41 - 43 - 51
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
PHYSICAL
mm
AIRFLOW
298 (35) - 840 (950) 840 (950)
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
AMBIENT
RANGE
FDT100VF1
T-PSA-3BW-E
REFRIGERANT & PIPEWORK
Weight (Indoor (Grille) - Outdoor)
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
12.1 - 12.0
17.7 - 16.6
22.0 - 20.2
kW
2.76 - 2.74
4.05 - 3.77
4.98 - 4.57
Start - Max Run Current
A
5.0 - 24.0
5.0 - 24.0
5.0 - 24.0
Suggested Fuse Size
A
32
32
32
Indoor Unit
£900
£944
£1,147
Grille
£160
£160
£160
Remote Controller
£63
£63
£63
Outdoor Unit
£1,665
£1,965
£2,245
Retail Price
£2,788
£3,132
£3,615
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
Yes** - VP25 (25id 32od)
mm
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
230 - 1 - 50
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 700mm from the underside of the ceiling tile | Knock out for branch duct 100mm x 100mm |
Knock out for fresh air intake 65mm x 112mm.
ampair.co.uk | 01707 378 670 | [email protected]
49
PAC Systems
FDT 4 Way Cassette Micro Inverter Single Phase
PAC Systems
FDT 4 Way Cassette Micro Inverter Three Phase
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
EFFICIENCY
FDT140VF
T-PSA-3BW-E
RC-E5
RC-E5
RC-E5
FDC100VS
FDC125VS
FDC140VS
14.0 (5.0 - 14.5)
kW
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
9.4 - 7.1
11.8 - 8.5
12.7 - 9.4
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Energy Label (Cool / Heat)
5.57 - 3.91
n/a
n/a
A/A
n/a
n/a
3.62 - 4.09
3.09 - 3.71
2.81 - 3.50
A/A
B/A
C/B
Operating Range Cool
°C
43 to -15
Operating Range Heat
°C
20 to -20
298 (35) - 840 (950) 840 (950)
298 (35) - 840 (950) 840 (950)
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
27.0 (5.5) - 81.0
27.0 (5.5) - 83.0
27.0 (5.5) - 83.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
333 - 400 - 450 - 617
383 - 450 - 500 - 617
383 - 450 - 500 - 617
Static Pressure
Pa
0
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
35 - 37 - 40 - 51
37 - 40 - 42 - 51
38 - 41 - 43 - 51
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
PHYSICAL
mm
AIRFLOW
298 (35) - 840 (950) 840 (950)
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
AMBIENT
RANGE
FDT125VF
T-PSA-3BW-E
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
REFRIGERANT & PIPEWORK
Weight (Indoor (Grille) - Outdoor)
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Yes** - VP25 (25id 32od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.2 - 4.2
5.9 - 5.5
7.4 - 6.7
kW
2.76 - 2.74
4.05 - 3.77
4.98 - 4.57
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20A per phase
20A per phase
20A per phase
Indoor Unit
£900
£944
£1,147
Grille
£160
£160
£160
Remote Controller
£63
£63
£63
Outdoor Unit
£1,744
£1,976
£2,277
Retail Price
£2,867
£3,143
£3,647
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
FDT100VF1
T-PSA-3BW-E
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 700mm from the underside of the ceiling tile | Knock out for branch duct 100mm x 100mm |
Knock out for fresh air intake 65mm x 112mm.
@amp_aircon |
amp-air-conditioning
50
PAC Systems
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
FDT60VF
T-PSA-3BW-E
RC-E5
RC-E5
RC-E5
SRC40ZMX-S
SRC50ZMX-S
SRC60ZMX-S
5.6 (1.1 - 6.3)
kW
4.0 (1.1 - 4.7)
5.0 (1.1 - 5.6)
UK Cooling (Total - Sensible)
kW
3.8 - 3.5
4.8 - 4.2
5.4 - 5.0
Nominal Heating (Range)
kW
4.5 (0.6 - 5.4)
5.4 (0.6 - 6.3)
6.7 (0.6 - 7.1)
UK Heating
kW
3.7
4.5
5.6
7.57 - 4.16
6.91 - 4.09
7.69 - 3.86
A++ / A+
A++ / A+
A++ / A
4.30 - 4.25
3.88 - 4.19
3.68 - 3.94
A/A
A/A
A/A
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Energy Label (Cool / Heat)
AMBIENT
RANGE
FDT50VF
T-PSA-3BW-E
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
°C
43 to -15
Operating Range Heat
°C
20 to -15
mm
246 (35) - 840 (950) 840 (950)
246 (35) - 840 (950) 840 (950)
246 (35) - 840 (950) 840 (950)
Outdoor Unit Dim. (H-W-D)
640 - 800 (+71) - 290
640 - 800 (+71) - 290
640 - 800 (+71) - 290
kg
22.0 (5.5) - 45.0
22.0 (5.5) - 45.0
24.0 (5.5) - 45.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
233 - 267 - 300 - 333
233 - 267 - 300 - 333
233 - 267 - 300 - 333
Static Pressure
Pa
0
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
30 - 31 - 33 - 39
30 - 31 - 33 - 39
30 - 31 - 33 - 46
Outdoor Sound Pressure (Cool-Heat)
dB(A)
50 - 50
54 - 50
54 - 54
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
1/2" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
30 - 20
REFRIGERANT & PIPEWORK
mm
Weight (Indoor (Grille) - Outdoor)
AIRFLOW
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
PHYSICAL
FDT40VF
T-PSA-3BW-E
Pre-Charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
1.5kg - 20g/m
1.5kg - 20g/m
1.5kg - 20g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
4.6 - 5.3
6.2 - 6.2
7.2 - 8.3
kW
0.93 - 1.06
1.29 - 1.29
1.52 - 1.70
Start - Max Run Current
A
5.0 - 12.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
16
20
20
Indoor Unit
£501
£595
£634
£160
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
Yes** - VP25 (25id 32od)
mm
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
Grille
£160
£160
Remote Controller
£63
£63
£63
Outdoor Unit
£880
£973
£1,102
Retail Price
£1,604
£1,791
£1,959
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 700mm from the underside of the ceiling tile | Knock out for branch duct 100mm x 100mm |
Knock out for fresh air intake 65mm x 112mm.
ampair.co.uk | 01707 378 670 | [email protected]
51
PAC Systems
FDT 4 Way Cassette Hyper Inverter Single Phase
PAC Systems
FDT 4 Way Cassette Hyper Inverter Single Phase
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
EFFICIENCY
RC-E5
RC-E5
FDC71VNX
FDC100VNX
10.0 (4.0 - 11.2)
kW
7.1 (3.2 - 8.0)
UK Cooling (Total - Sensible)
kW
6.7 - 5.9
9.4 - 8.2
Nominal Heating (Range)
kW
8.0 (3.6 - 9.0)
11.2 (4.0 - 12.5)
UK Heating
kW
5.6
10.1
5.72 - 4.09
5.84 - 3.96
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Energy Label (Cool / Heat)
A+ / A+
A+ / A
3.48 - 4.12
4.00 - 4.34
A/A
A/A
°C
43 to -15
Operating Range Heat
°C
20 to -20
mm
246 (35) - 840 (950) - 840 (950)
Outdoor Unit Dim. (H-W-D)
mm
750 - 880 (+88) - 340
1300 - 970 - 370
kg
24.0 (5.5) - 60.0
27.0 (5.5) - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
283 - 317 - 350 - 467
333 - 400 - 450 - 617
Static Pressure
Pa
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
31 - 33 - 35 - 46
35 - 37 - 40 - 51
Outdoor Sound Pressure (Cool-Heat)
dB(A)
51 - 48
48 - 50
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
100 - 30*
PHYSICAL
Indoor (Grille) Unit Dimensions (H-W-D)
AIRFLOW
Operating Range Cool
SOUND
AMBIENT
RANGE
FDT100VF1
T-PSA-3BW-E
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
REFRIGERANT & PIPEWORK
Weight (Indoor (Grille) - Outdoor)
298 (35) - 840 (950) - 840 (950)
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
2.95 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Yes
Yes** - VP25 (25id 32od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
9.1 - 8.7
11.1 - 11.4
kW
2.04 - 1.94
2.50 - 2.58
Start - Max Run Current
A
5.0 - 17.0
2.0 - 24.0
Suggested Fuse Size
A
25
32
Indoor Unit
£675
£900
Grille
£160
£160
Remote Controller
£63
£63
Outdoor Unit
£1,546
£2,068
Retail Price
£2,444
£3,191
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
FDT71VF1
T-PSA-3BW-E
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 700mm from the underside of the ceiling tile | Knock out for branch duct 100mm x 100mm |
Knock out for fresh air intake 65mm x 112mm.
@amp_aircon |
amp-air-conditioning
52
PAC Systems
Indoor Unit
Grille
Remote Controller inc. Time Clock
EFFICIENCY
PERFORMANCE
Outdoor Unit
FDT140VF
T-PSA-3BW-E
RC-E5
RC-E5
FDC125VNX
FDC140VNX
14.0 (5.0 - 16.0)
Nominal Cooling (Range)
kW
12.5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
11.8 - 9.3
13.2 - 10.1
Nominal Heating (Range)
kW
14.0 (4.0 - 17.0)
16.0 (4.0 - 18.0)
UK Heating
kW
12.6
14.4
SEER - SCOP (Cool - Heat)
n/a
n/a
ERP (Cool / Heat)
n/a
n/a
3.81 - 4.08
3.34 - 3.81
A/A
A/A
EER - COP (Cool - Heat)
Energy Label (Cool / Heat)
Operating Range Cool
°C
43 to -15
Operating Range Heat
°C
20 to -20
298 (35) - 840 (950) - 840 (950)
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
kg
27.0 (5.5) - 105.0
27.0 (5.5) - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
383 - 450 - 500 - 617
383 - 450 - 500 - 617
Static Pressure
Pa
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
37 - 40 - 42 - 51
38 - 41 - 43 - 51
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
PHYSICAL
mm
AIRFLOW
298 (35) - 840 (950) - 840 (950)
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
AMBIENT
RANGE
FDT125VF
T-PSA-3BW-E
REFRIGERANT & PIPEWORK
Weight (Indoor (Grille) - Outdoor)
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
14.6 - 15.2
18.6 - 18.6
kW
3.28 - 3.43
4.19 - 4.20
Start - Max Run Current
A
5.0 - 26.0
5.0 - 26.0
Suggested Fuse Size
A
32
32
Indoor Unit
£944
£1,147
Grille
£160
£160
Remote Controller
£63
£63
Outdoor Unit
£2,424
£2,722
Retail Price
£3,591
£4,092
Interconnecting Cables
POWER
Yes
Yes** - VP25 (25id 32od)
mm
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 700mm from the underside of the ceiling tile | Knock out for branch duct 100mm x 100mm |
Knock out for fresh air intake 65mm x 112mm.
ampair.co.uk | 01707 378 670 | [email protected]
53
PAC Systems
FDT 4 Way Cassette Hyper Inverter Single Phase
PAC Systems
FDT 4 Way Cassette Hyper Inverter Three Phase
Indoor Unit
Grille
Remote Controller inc. Time Clock
PERFORMANCE
EFFICIENCY
FDT140VF
T-PSA-3BW-E
RC-E5
RC-E5
RC-E5
FDC100VSX
FDC125VSX
FDC140VSX
14.0 (5.0 - 16.0)
kW
10.0 (4.0 - 11.2)
12 .5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
9.4 - 8.2
11.8 - 8.3
13.2 - 10.1
Nominal Heating (Range)
kW
11.2 (4.0 - 16.0)
14.0 (4.0 - 18.0)
16.0 (4.0 - 20.0)
UK Heating
kW
11.4
14.3
16.3
5.79 - 3.95
n/a
n/a
A+ / A
n/a
n/a
4.00 - 4.34
3.81 - 4.08
3.34 - 3.81
A/A
A/A
A/A
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Energy Label (Cool / Heat)
Operating Range Cool
°C
43 to -15
Operating Range Heat
°C
20 to -20
298 (35) - 840 (950) 840 (950)
298 (35) - 840 (950) 840 (950)
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
1300 - 970 - 370
kg
27.0 (5.5) - 105.0
27.0 (5.5) - 105.0
27.0 (5.5) - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
333 - 400 - 450 - 617
383 - 450 - 500 - 617
383 - 450 - 500 - 617
Static Pressure
Pa
0
0
0
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
35 - 37 - 40 - 51
37 - 40 - 42 - 51
38 - 41 - 43 - 51
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
100 - 30*
PHYSICAL
mm
AIRFLOW
298 (35) - 840 (950) 840 (950)
Indoor (Grille) Unit Dimensions (H-W-D)
SOUND
AMBIENT
RANGE
FDT125VF
T-PSA-3BW-E
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
REFRIGERANT & PIPEWORK
Weight (Indoor (Grille) - Outdoor)
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
4.5 - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Yes** - VP25 (25id 32od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
3.9 - 4.0
4.8 - 5.1
6.2 - 6.2
kW
2.50 - 2.58
3.28 - 3.43
4.19 - 4.20
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20 per phase
20 per phase
20 per phase
Indoor Unit
£900
£944
£1,147
Grille
£160
£160
£160
Remote Controller
£63
£63
£63
Outdoor Unit
£2,240
£2,520
£2,848
Retail Price
£3,363
£3,687
£4,218
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
FDT100VF1
T-PSA-3BW-E
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 700mm from the underside of the ceiling tile | Knock out for branch duct 100mm x 100mm |
Knock out for fresh air intake 65mm x 112mm.
@amp_aircon |
amp-air-conditioning
54
PAC Systems
PAC Systems
FDUM Standard Ducted
FDUM Standard Ducted Unit
FDC100VNX Outdoor Unit
»» Available with a range of outdoors, offering high
»» Lift pump fitted as standard 600mm from
»»
»»
»»
»»
»»
»» Available with a range of hard-wired & infrared
SEERs and SCOPs
Indoor units only 280mm high
External static pressure control function
Extended pipe runs, up to 100m
Suitable for replacement technology (see below)
Selected outdoor units with Blue Fin protection
Compatible Accessories
List
Price
Part No.
Description
RC-E5*
Wired remote controller with 7-day
time clock
£63
RC-EX1A
Premium wired touch screen
controller with 7-day time clock
£123
RCH-E3
Simplified wired remote controller
£106
RCN-KIT3-E
Infrared remote controller kit
£166
SC-THB-E3
Remote return air sensor
£82
SC-ADNA-E
Superlink network adapter for
connection to central controllers
£106
PCZ006A043
CNT connector for remote on/off,
run/fault etc.
£10
FM-MRFVF
CNT indoor run fault adapter
(volt free)
£110
underside of unit
controls
»» Can connect to centralised controller via superlink
network (SC-ADNA-E adapter required)
»» Available in twin & triple systems (see page 86)
Existing
Pipe Sizes
Liquid Gas
Allowable Outdoors
Standard
Inverter VNP
Micro Inverter
VN & VS
Hyper Inverter
ZMX-S, VNX
& VSX
1/4"
1/2"
71
40-50-60
1/4"
5/8"
71
71-100-125-140
3/8"
1/2"
71
3/8"
5/8"
71-100
3/8"
3/4"
1/2"
5/8"
1/2"
3/4"
100
40-50-60-71
100-125-140
71-100-125-140
100-125-140
100-125-140
100-125-140
71-100-125-140
100-125-140
100-125-140
Subject to the pipe sizes used and selected outdoor unit additional pipe work and
capacity, limitations may apply.
Contact AMP for details.
*Included in system price as standard. See page 173 for other controls and
accessories.
ampair.co.uk | 01707 378 670 | [email protected]
55
PAC Systems
FDUM Standard Ducted Standard Inverter
Indoor Unit
FDUM71VF1
FDUM100VF2
Spigot Kit
AMP-FDUM-3
AMP-FDUM-4
UM-FL2EF
UM-FL3EF
Return Air Filter
Remote Controller inc. Time Clock
PERFORMANCE
EFFICIENCY
10 (2.8 - 11.2)
kW
7.1 (1.4 - 7.1)
kW
6.9 - 5.6
9.38 - 7.38
Nominal Heating (Range)
kW
7.1 (1.0 - 7.1)
11.2 (2.5 - 12.5)
UK Heating
kW
5.2
7.30
5.71 - 4.00
6.36 - 4.13
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC100VNP
UK Cooling (Total - Sensible)
A+ / A+
A++ / A+
2.70 - 3.62
3.33 - 3.82
D/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC71VNP
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
A/A
46 to -15
°C
Operating Range Heat
20 to -15
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 950 - 635
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
640 - 800 (+71) - 290
845 - 970 - 370
kg
34 - 45
54 - 70
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
167 - 250 - 317 - 400
266 - 416 - 466 - 600
Static Pressure
Pa
35 - 100
60 - 100
3 x 200mm
4 x 200mm
30 - 36 - 38 - 44
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
25 - 29 - 33 - 38
Outdoor Sound Pressure (Cool-Heat)
dB(A)
54 - 54
57 - 61
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"*
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
Pre-Charged for
m
15
15
Charge R410A (Factory - Additional)
kg
1.6kg - 20g/m
2.55kg - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
Yes** - VP20 or VP25
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
11.70 - 8.80
13.20 - 12.90
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
RC-E5
kW
2.63 - 1.96
2.93 - 3.00
Start - Max Run Current
A
5.0 - 14.5
5.0 - 22.0
Suggested Fuse Size
A
16
25
Indoor Unit
£721
£1,076
Spigot Kit
£54
£67
Return Air Filter
£72
£72
Remote Controller
£63
£63
Outdoor Unit
£1,329
£1,536
Retail Price
£2,239
£2,814
Power Cons. (Cool - Heat)
* Outdoor includes 3/8” & 5/8” reducers for indoor unit connection | **Lift pump as standard, 600mm from the underside of the unit | As standard units come with rectangular
air outlets, the optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | No return air filter as standard.
@amp_aircon |
amp-air-conditioning
56
PAC Systems
Indoor Unit
FDUM100VF1
FDUM125VF
FDUM140VF
Spigot Kit
AMP-FDUM-4
AMP-FDUM-4
AMP-FDUM-4
UM-FL3EF
UM-FL3EF
UM-FL3EF
RC-E5
RC-E5
RC-E5
FDC100VN
FDC125VN
FDC140VN
14.0 (5.0 - 14.5)
Return Air Filter
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
Nominal Cooling (Range)
kW
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
9.4 - 7.3
11.8 - 9.9
13.2 - 10.6
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
5.06 - 3.94
n/a
n/a
B/A
n/a
n/a
3.57 - 3.71
3.21 - 3.61
2.83 - 3.41
A/A
C/B
EFFICIENCY
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
A/A
REFRIGERANT & PIPEWORK
SOUND
AIRFLOW
PHYSICAL
AMBIENT
RANGE
Energy Label (Cool / Heat)
Operating Range Cool
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
54 - 81
54 - 81
54 - 81
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
317 - 417 - 467 - 600
333 - 433 - 533 - 650
367 - 467 - 583 - 800
Static Pressure
Pa
60 - 100
60 - 100
60 - 100
4 x 200mm
4 x 200mm
4 x 200mm
30 - 35 - 40 - 47
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
30 - 36 - 38 - 44
29 - 34 - 40 - 45
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Yes** - VP20 or VP25
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
12.6 - 13.5
17.5 - 17.4
22.2 - 21.0
V-Ph-Hz
Interconnecting Cables
POWER
43 to -15
°C
230 - 1 - 50
kW
2.80 - 3.02
3.90 - 3.88
4.95 - 4.69
Start - Max Run Current
A
5.0 - 24.0
5.0 - 24.0
5.0 - 24.0
Suggested Fuse Size
A
32
32
32
Power Cons. (Cool - Heat)
Indoor Unit
£1,076
£1,142
£1,233
Spigot Kit
£67
£67
£67
Return Air Filter
£72
£72
£72
Remote Controller
£63
£63
£63
Outdoor Unit
£1,665
£1,965
£2,245
Retail Price
£2,943
£3,309
£3,680
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | As standard units come with rectangular air outlets, the
optional amp spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | No return air filter as standard.
ampair.co.uk | 01707 378 670 | [email protected]
57
PAC Systems
FDUM Standard Ducted Micro Inverter Single Phase
PAC Systems
FDUM Standard Ducted Micro Inverter Three Phase
Indoor Unit
FDUM100VF1
FDUM125VF
FDUM140VF
Spigot Kit
AMP-FDUM-4
AMP-FDUM-4
AMP-FDUM-4
UM-FL3EF
UM-FL3EF
UM-FL3EF
RC-E5
RC-E5
RC-E5
FDC100VS
FDC125VS
FDC140VS
14.0 (5.0 - 14.5)
Return Air Filter
Remote Controller inc. Time Clock
PERFORMANCE
Nominal Cooling (Range)
kW
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
9.4 - 7.3
11.8 - 9.9
13.2 - 10.6
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
5.03 - 3.94
n/a
n/a
B/A
n/a
n/a
3.57 - 3.71
3.21 - 3.61
2.83 - 3.41
A/A
C/B
EFFICIENCY
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
A/A
REFRIGERANT & PIPEWORK
SOUND
AIRFLOW
PHYSICAL
AMBIENT
RANGE
Energy Label (Cool / Heat)
Operating Range Cool
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
54 - 83
54 - 83
54 - 83
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
317 - 417 - 467 - 600
333 - 433 - 533 - 650
367 - 467 - 583 - 800
Static Pressure
Pa
60 - 100
60 - 100
60 - 100
4 x 200mm
4 x 200mm
4 x 200mm
30 - 35 - 40 - 47
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
30 - 36 - 38 - 44
29 - 34 - 40 - 45
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
Yes** - VP20 or VP25
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.2 - 4.5
5.8 - 5.8
7.4 - 7.0
kW
2.80 - 3.02
3.90 - 3.88
4.95 - 4.69
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20A per phase
20A per phase
20A per phase
Indoor Unit
£1,076
£1,142
£1,233
Spigot Kit
£67
£67
£67
Return Air Filter
£72
£72
£72
Remote Controller
£63
£63
£63
Outdoor Unit
£1,744
£1,976
£2,277
Retail Price
£3,022
£3,320
£3,712
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | As standard units come with rectangular air outlets, the
optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | No return air filter as standard.
@amp_aircon |
amp-air-conditioning
58
PAC Systems
Indoor Unit
Spigot Kit
Return Air Filter
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDUM60VF
AMP-FDUM-2
AMP-FDUM-2
AMP-FDUM-3
UM-FL1EF
UM-FL1EF
UM-FL2EF
RC-E5
RC-E5
RC-E5
SRC40ZMX-S
SRC50ZMX-S
SRC60ZMX-S
5.6 (1.1 - 6.3)
kW
4.0 (1.1 - 4.7)
5.0 (1.1 - 5.6)
UK Cooling (Total - Sensible)
kW
3.8 - 3.2
4.8 - 3.7
5.4 - 4.6
Nominal Heating (Range)
kW
4.5 (0.6 - 5.4)
5.4 (0.6 - 6.3)
6.7 (0.6 - 7.1)
UK Heating
kW
3.7
4.5
5.6
6.01 - 4.15
5.68 - 4.36
6.42 - 4.37
A+ / A+
A+ / A+
A++ / A+
4.20 - 4.21
3.62 - 3.72
3.64 - 3.83
A/A
A/A
ERP (Cool / Heat)
EER - COP (Cool - Heat)
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDUM50VF
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
Operating Range Heat
43 to -15
°C
20 to -15
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 750 - 635
280 - 750 - 635
280 - 950 - 635
Outdoor Unit Dim. (H-W-D)
mm
640 - 800 (+71) - 290
640 - 800 (+71) - 290
640 - 800 (+71) - 290
kg
29.0 - 45.0
29.0 - 45.0
34.0 - 45.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
133 - 150 - 167 - 217
133 - 150 - 167 - 217
167 - 217 - 250 - 333
Static Pressure
Pa
35 - 100
35 - 100
35 -100
2 x 200mm
2 x 200mm
3 x 200mm
25 - 28 - 31 - 36
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
26 - 29 - 32 - 37
26 - 29 - 32 - 37
Outdoor Sound Pressure (Cool-Heat)
dB(A)
50 - 50
54 - 50
54 - 54
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
1/2" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
30 - 20
Pre-Charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
1.5kg - 20g/m
1.5kg - 20g/m
1.5kg - 20g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Yes** - VP20 or VP25
mm
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
4.6 - 5.1
6.6 - 6.9
7.1 - 8.2
kW
0.95 - 1.07
1.38 - 1.45
1.54 - 1.75
Start - Max Run Current
A
5.0 - 12.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
16
20
20
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
FDUM40VF
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
Indoor Unit
£580
£587
£602
Spigot Kit
£40
£40
£54
Return Air Filter
£72
£72
£72
Remote Controller
£63
£63
£63
Outdoor Unit
£880
£973
£1,102
Retail Price
£1,635
£1,735
£1,893
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | As standard units come with rectangular air outlets, the
optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | No return air filter as standard.
ampair.co.uk | 01707 378 670 | [email protected]
59
PAC Systems
FDUM Std. Ducted Hyper Inverter Single Phase
PAC Systems
FDUM Std. Ducted Hyper Inverter Single Phase
Indoor Unit
FDUM71VF1
FDUM100VF1
Spigot Kit
AMP-FDUM-3
AMP-FDUM-4
UM-FL2EF
UM-FL3EF
Return Air Filter
Remote Controller inc. Time Clock
PERFORMANCE
EFFICIENCY
10.0 (4.0 - 11.2)
kW
7.1 (3.2 - 8.0)
kW
6.7 - 5.5
9.4 - 7.3
Nominal Heating (Range)
kW
8.0 (3.6 - 9.0)
11.2 (4.0 - 12.5)
UK Heating
kW
5.6
10.1
5.24 - 3.90
5.22 - 4.10
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC100VNX
UK Cooling (Total - Sensible)
A/A
A / A+
3.50 - 4.02
3.73 - 3.71
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC71VNX
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
A/A
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 950 - 635
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
750 - 880 (+88) - 340
1300 - 970 - 370
kg
34.0 - 60.0
54.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
167 - 250 - 317 - 400
317 - 417 - 467 - 600
Static Pressure
Pa
35 - 100
60 - 100
3 x 200mm
4 x 200mm
30 - 36 - 38 - 44
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
25 - 29 - 33 - 38
Outdoor Sound Pressure (Cool-Heat)
dB(A)
51 - 48
48 - 50
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
2.95 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
Yes** - VP20 or VP25
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
9.0 - 9.0
12.0 - 13.5
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
RC-E5
kW
2.03 - 1.99
2.68 - 3.02
Start - Max Run Current
A
5.0 - 17.0
2.0 - 24.0
Suggested Fuse Size
A
25
32
Indoor Unit
£721
£1,076
Spigot Kit
£54
£67
Return Air Filter
£72
£72
Remote Controller
£63
£63
Outdoor Unit
£1,546
£2,068
Retail Price
£2,456
£3,346
Power Cons. (Cool - Heat)
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | As standard units come with rectangular air outlets, the
optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | No return air filter as standard.
@amp_aircon |
amp-air-conditioning
60
PAC Systems
Indoor Unit
FDUM125VF
FDUM140VF
Spigot Kit
AMP-FDUM-4
AMP-FDUM-4
UM-FL3EF
UM-FL3EF
Return Air Filter
Remote Controller inc. Time Clock
EFFICIENCY
PERFORMANCE
Outdoor Unit
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
REFRIGERANT & PIPEWORK
RC-E5
FDC125VNX
FDC140VNX
14.0 (5.0 - 16.0)
Nominal Cooling (Range)
kW
12.5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
11.8 - 9.9
13.2 - 10.6
Nominal Heating (Range)
kW
14.0 (4.0 - 17.0)
16.0 (4.0 - 18.0)
UK Heating
kW
12.6
14.4
SEER - SCOP (Cool - Heat)
n/a
n/a
ERP (Cool / Heat)
n/a
n/a
3.58 - 3.71
3.27 - 3.62
EER - COP (Cool - Heat)
A/A
Energy Label (Cool / Heat)
Operating Range Cool
Operating Range Heat
A/A
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
kg
54.0 - 105.0
54.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
333 - 433 - 533 - 650
367 - 467 - 583 - 800
Static Pressure
Pa
60 - 100
60 - 100
4 x 200mm
4 x 200mm
30 - 35 - 40 - 47
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
29 - 34 - 40 - 45
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
Yes** - VP20 or VP25
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
15.5 - 16.8
19.2 - 20.1
Interconnecting Cables
POWER
RC-E5
kW
3.49 - 3.77
4.28 - 4.42
Start - Max Run Current
A
5.0 - 29.0
5.0 - 30.0
Suggested Fuse Size
A
32
32
Power Cons. (Cool - Heat)
Indoor Unit
£1,142
£1,233
Spigot Kit
£67
£67
Return Air Filter
£72
£72
Remote Controller
£63
£63
Outdoor Unit
£2,424
£2,722
Retail Price
£3,768
£4,157
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | As standard units come with rectangular air outlets, the
optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | No return air filter as standard.
ampair.co.uk | 01707 378 670 | [email protected]
61
PAC Systems
FDUM Std. Ducted Hyper Inverter Single Phase
PAC Systems
FDUM Std. Ducted Hyper Inverter Three Phase
Indoor Unit
FDUM100VF1
FDUM125VF
FDUM140VF
Spigot Kit
AMP-FDUM-4
AMP-FDUM-4
AMP-FDUM-4
UM-FL3EF
UM-FL3EF
UM-FL3EF
RC-E5
RC-E5
RC-E5
FDC100VSX
FDC125VSX
FDC140VSX
14.0 (5.0 - 16.0)
Return Air Filter
Remote Controller inc. Time Clock
PERFORMANCE
Nominal Cooling (Range)
kW
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
UK Cooling (Total - Sensible)
kW
9.4 - 7.3
11.8 - 9.9
13.2 - 10.6
Nominal Heating (Range)
kW
11.2 (4.0 - 16.0)
14.0 (4.0 - 18.0)
16.0 (4.0 - 20.0)
UK Heating
kW
11.4
14.3
16.3
5.19 - 4.10
n/a
n/a
A / A+
n/a
n/a
3.73 - 3.71
3.58 - 3.71
3.27 - 3.62
A/A
A/A
EFFICIENCY
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
A/A
REFRIGERANT & PIPEWORK
SOUND
AIRFLOW
PHYSICAL
AMBIENT
RANGE
Energy Label (Cool / Heat)
Operating Range Cool
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
1300 - 970 - 370
kg
54.0 - 105.0
54.0 - 105.0
54.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
317 - 417 - 467 - 600
333 - 433 - 533 - 650
367 - 467 - 583 - 800
Static Pressure
Pa
60 - 100
60 - 100
60 - 100
4 x 200mm
4 x 200mm
4 x 200mm
30 - 35 - 40 - 47
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
30 - 36 - 38 - 44
29 - 34 - 40 - 45
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
4.5 - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
Yes** - VP20 or VP25
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.0 - 4.5
5.2 - 5.6
6.4 - 6.6
kW
2.68 - 3.02
3.49 - 3.77
4.28 - 4.42
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
Outdoor Unit
Start - Max Run Current
A
5.0 - 15.0
5.0 - 18.0
5.0 - 19.0
Suggested Fuse Size
A
20 per phase
20 per phase
20 per phase
Indoor Unit
£1,076
£1,142
£1,233
Spigot Kit
£67
£67
£67
Return Air Filter
£72
£72
£72
Remote Controller
£63
£63
£63
Outdoor Unit
£2,240
£2,520
£2,848
Retail Price
£3,518
£3,864
£4,283
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | As standard units come with rectangular air outlets, the
optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible ductwork | No return air filter as standard.
@amp_aircon |
amp-air-conditioning
62
PAC Systems
PAC Systems
FDU High Static Ducted
FDU High Static Ducted Indoor Unit
FDC250VS Outdoor Unit
»» Available with a range of outdoors, with a range of
capacities up to 25kW cooling
»» Extended pipe runs, up to 100m depending on
model
»» Suitable for replacement technology (see below)
»» Selected outdoor units with Blue Fin protection
Compatible Accessories
List
Price
Part No.
Description
RC-E5*
Wired remote controller with 7-day
time clock
£63
RC-EX1A
Premium wired touch screen
controller with 7-day time clock
£123
Simplified wired remote controller
£106
RCN-KIT3-E
Infrared remote controller kit
£166
SC-THB-E3
Remote return air sensor
£82
SC-ADNA-E
Superlink network adapter for
connection to central controllers
£106
CNT connector for remote on/off,
run/fault etc.
£10
CNT indoor run fault adapter
(volt free)
£110
FM-MRFVF
underside of unit
»» Available with a range of hard wired and infrared
control options
»» Can connect to centralised controller via superlink
network (SC-ADNA-E adapter required)
Existing
Pipe Sizes
Liquid Gas
1/4"
RCH-E3
PCZ006A043
»» Lift pump fitted as standard, 600mm from
*Included in system price as standard. See page 173 for other controls and
accessories.
1/2"
Allowable Outdoors
Standard
Inverter VNP
Micro Inverter
VN & VS
Hyper Inverter
ZMX-S, VNX
& VSX
71
1/4"
5/8"
71
3/8"
1/2"
71
3/8"
5/8"
71-100
3/8"
3/8"
3/8"
1 1/8"
1/2"
5/8"
1/2"
1/2"
71-100-125-140
71
100-125-140
71-100-125-140
3/4"
100-125-140
100-125-140
7/8"
200
200
100
100-125-140
71-100-125-140
3/4"
100-125-140
100-125-140
7/8"
200-250
1/2"
1 1/8"
200-250
5/8"
7/8"
200-250
5/8"
1 1/8"
200-250
Subject to the pipe sizes used and selected outdoor unit additional pipe work and
capacity, limitations may apply.
Contact AMP for details.
ampair.co.uk | 01707 378 670 | [email protected]
63
PAC Systems
FDU High Static Ducted Standard Inverter
Indoor Unit
FDU71VF1
Remote Controller inc. Time Clock
EFFICIENCY
7.1 (1.4 - 7.1)
10.0 (2.8 - 11.2)
kW
kW
6.9 - 5.6
9.38 - 7.38
Nominal Heating (Range)
kW
7.1 (1.0 - 7.1)
11.2 (2.5 - 12.5)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
FDC100VNP
UK Cooling (Total - Sensible)
5.2
7.30
5.71 - 4.00
6.36 - 4.13
A+ / A+
A++ / A+
2.70 - 3.62
3.33 - 3.82
D/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC71VNP
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
°C
Operating Range Heat
°C
A/A
46 to -15
20 to -15
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 950 - 635
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
640 - 800 (+71) - 290
845 - 970 - 370
kg
34 - 45
54 - 70
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
167 - 250 - 317 - 400
317 - 417 - 467 - 600
Static Pressure
Pa
35 - 200
60 - 200
rect. 880 x 170
rect. 1200 x 170
25 - 29 - 33 - 38
30 - 36 - 38 - 44
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
54 - 54
57 - 61
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"*
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
Pre-Charged for
m
15
15
Charge R410A (Factory - Additional)
kg
1.6kg - 20g/m
2.55kg - 60g/m
Yes
Yes
mm
Yes** - VP20 (20id 26od)
Yes** - VP25 (25id 32od)
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
3 core + E
3 core + E
A
11.70 - 8.80
12.90 - 13.20
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDU100VF2
Running Current (Cool - Heat)
kW
2.63 - 1.96
2.93 - 3.00
Start - Max Run Current
A
5.0 - 14.5
5.0 - 22
Suggested Fuse Size
A
16
25
Indoor Unit
£779
£971
Remote Controller
£63
£63
Power Cons. (Cool - Heat)
Outdoor Unit
£1,329
£1,536
Retail Price
£2,171
£2,570
* Outdoor includes 3/8" & 5/8" reducers for indoor unit connection | **Lift pump as standard, 600mm from the underside of the unit.
@amp_aircon |
amp-air-conditioning
64
PAC Systems
FDU High Static Ducted Micro Inverter Single Phase
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
FDU140VF
RC-E5
FDC100VN
FDC125VN
FDC140VN
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
UK Cooling (Total - Sensible)
kW
9.4 - 7.3
11.8 - 9.9
13.2 - 10.6
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
5.06 - 3.94
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
B/A
n/a
n/a
3.47 - 3.75
3.09 - 3.69
2.83 - 3.61
B/A
C/A
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDU125VF
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
63 - 81
63 - 81
63 - 81
Indoor Unit Airflow Rate (L-H)
l/s
450 - 567
558 - 700
558 - 700
Static Pressure
Pa
60 - 130
60 - 130
60 - 130
rect. 1200 x 170
rect. 1200 x 170
rect. 1200 x 170
37 - 42
38 - 43
38 - 43
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-H)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Yes** - VP25 (25id 32od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
12.7 - 13.1
17.8 - 16.6
21.7 - 19.5
V-Ph-Hz
Interconnecting Cables
POWER
FDU100VF1
230 - 1 - 50
kW
2.88 - 2.99
4.04 - 3.79
4.95 - 4.43
Start - Max Run Current
A
5.0 - 25.0
5.0 - 27.0
5.0 - 28.0
Suggested Fuse Size
A
32
32
32
Indoor Unit
£971
£1,180
£1,215
Remote Controller
£63
£63
£63
Power Cons. (Cool - Heat)
Outdoor Unit
£1,665
£1,965
£2,245
Retail Price
£2,699
£3,208
£3,523
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | Unit does not come with return air filter.
ampair.co.uk | 01707 378 670 | [email protected]
65
PAC Systems
Indoor Unit
Remote Controller inc. Time Clock
PAC Systems
FDU High Static Ducted Micro Inverter Three Phase
Indoor Unit
Remote Controller inc. Time Clock
EFFICIENCY
FDU140VF
RC-E5
FDC100VS
FDC125VS
FDC140VS
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
kW
9.4 - 7.3
11.8 - 9.9
13.2 - 10.6
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
5.03 - 3.94
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
UK Cooling (Total - Sensible)
B/A
n/a
n/a
3.47 - 3.75
3.09 - 3.69
2.83 - 3.61
B/A
C/A
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDU125VF
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
63 - 83
63 - 83
63 - 83
Indoor Unit Airflow Rate (L-H)
l/s
450 - 567
558 - 700
558 - 700
Static Pressure
Pa
60 - 130
60 - 130
60 - 130
rect. 1200 x 170
rect. 1200 x 170
rect. 1200 x 170
37 - 42
38 - 43
38 - 43
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-H)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
Yes** - VP25 (25id 32od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.3 - 4.4
6.0 - 5.6
7.4 - 6.6
kW
2.88 - 2.99
4.04 - 3.79
4.95 - 4.43
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDU100VF1
Start - Max Run Current
A
5.0 - 16.0
5.0 - 18.0
5.0 - 19.0
Suggested Fuse Size
A
20A per phase
20A per phase
20A per phase
Indoor Unit
£971
£1,180
£1,215
Remote Controller
£63
£63
£63
Outdoor Unit
£1,744
£1,976
£2,277
Retail Price
£2,778
£3,219
£3,555
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | Unit does not come with return air filter.
@amp_aircon |
amp-air-conditioning
66
PAC Systems
FDU High Static Ducted Micro Inverter Three Phase
FDU200VF
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
20.0 (7.0 - 22.4)
25.0 (10.0 - 28.0)
kW
kW
18.7 - 13.9
23.4 - 19.2
Nominal Heating (Range)
kW
22.4 (7.6 - 25.0)
28.0 (9.5 - 31.5)
UK Heating
kW
15.7
19.6
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC250VS
UK Cooling (Total - Sensible)
Operating Range Cool
Operating Range Heat
n/a
n/a
3.03 - 3.68
2.52 - 3.29
B/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC200VS
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
E/C
20 to -15
°C
mm
360 - 1570 - 830
360 - 1570 - 830
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1505 - 970 - 370
Weight (Indoor (Grille) - Outdoor)
Kg
92 - 122
92 - 140
Indoor Unit Airflow Rate (L-H)
L/s
hi 850 - 1000
hi 1133 - 1333
Static Pressure
Pa
200
200
rect. 1450 x 250
rect. 1450 x 250
51
52
Discharge Spigots
Indoor Sound Pressure
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
57 - 57
57 - 58
Pipe Sizes (Gas - Liquid)
in
7/8" - 3/8"***
1 1/8" - 1/2"
Pipe Limits (Max Run - Height Diff.)
m
70 - 30*
70 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
5.4kg - 120g/m
7.2kg - 120g/m
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Cons. (Cool - Heat)
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
A
10.8 - 10.2
15.7 - 14.4
kW
6.59 - 6.08
9.91 - 8.50
Interconnecting Cables
Running Current (Cool - Heat)
No - VP25 (25id 32od)
mm
V-Ph-Hz
Start - Max Run Current
A
5.0 -24.0
5.0 - 27.0
Suggested Fuse Size
A
32A per phase
32A per phase
£2,703
£2,908
£63
£63
Indoor Unit
Remote Controller
For 200 & 250 models,
ensure indoor unit is
installed in the correct
orientation as shown above.
43 to -15
°C
Indoor (Grille) Unit Dimensions (H-W-D)
Power Supply (Outdoor)
POWER
FDU250VF
RC-E5
PAC Systems
Indoor Unit
Outdoor Unit
£3,086
£3,489
Retail Price
£5,852
£6,460
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | *** If pipe run is
greater than 35m increase gas pipe to 1 1/8",if pipe run is greater than 40m increase liquid pipe to 1/2" |
Unit does not come with return air filter.
ampair.co.uk | 01707 378 670 | [email protected]
67
PAC Systems
FDU High Static Ducted Hyper Inverter Sgl. Phase
Indoor Unit
FDU71VF1
Remote Controller inc. Time Clock
EFFICIENCY
7.1 (3.2 - 8.0)
10.0 (4.0 - 11.2)
kW
kW
6.7 - 5.7
9.5 - 8.0
Nominal Heating (Range)
kW
8.0 (3.6 - 9.0)
11.2 (4.0 - 12.5)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC100VNX
UK Cooling (Total - Sensible)
5.6
10.1
5.24 - 3.90
5.22 - 4.10
A/A
A / A+
3.46 - 3.98
3.73 - 3.71
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC71VNX
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
A/A
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 950 - 635
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
750 - 880 (+88) - 340
1300 - 970 - 370
kg
34.0 - 60.0
54.0 - 105.0
Indoor Unit Airflow Rate (L-H)
l/s
283 - 333
450 - 567
Static Pressure
Pa
35 - 200
60 - 200
rect. 880 x 170
rect. 1200 x 170
25 - 29 - 33 - 36
30 - 36 - 38 - 44
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
51 - 48
48 - 50
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
2.95 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
Yes** - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
9.6 - 9.5
12.0 - 13.5
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDU100VF1
RC-E5
kW
2.05 - 2.01
2.68 - 3.02
Start - Max Run Current
A
5.0 - 17.0
5.0 - 25.0
Suggested Fuse Size
A
25
32
Indoor Unit
£779
£971
Remote Controller
£63
£63
Power Cons. (Cool - Heat)
Outdoor Unit
£1,546
£2,068
Retail Price
£2,388
£3,102
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | Unit does not come with return air filter.
@amp_aircon |
amp-air-conditioning
68
PAC Systems
FDU High Static Ducted Hyper Inverter Sgl. Phase
FDU125VF
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC140VNX
12.5 (5.0 - 14.0)
14.0 (5.0 - 16.0)
kW
UK Cooling (Total - Sensible)
kW
11.8 - 10.0
13.2 - 10.5
Nominal Heating (Range)
kW
14.0 (4.0 - 17.0)
16.0 (4.0 - 18.0)
UK Heating
kW
12.6
14.4
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
n/a
n/a
3.58 - 3.71
3.27 - 3.62
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC125VNX
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
A/A
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
kg
54.0 - 105.0
54.0 - 105.0
Indoor Unit Airflow Rate (L-H)
l/s
558 - 700
558 - 700
Static Pressure
Pa
60 - 200
60 - 200
rect. 1200 x 170
rect. 1200 x 170
29 - 34 - 40 - 45
30 - 35 - 40 - 46
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
Yes** - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
15.3 - 16.3
19.2 - 19.1
Interconnecting Cables
POWER
FDU140VF
RC-E5
kW
3.49 - 3.77
4.28 - 4.42
Start - Max Run Current
A
5.0 - 29.0
5.0 - 30.0
Suggested Fuse Size
A
40
40
£1,180
£1,215
£63
£63
Power Cons. (Cool - Heat)
Indoor Unit
Remote Controller
Outdoor Unit
£2,424
£2,722
Retail Price
£3,667
£4,000
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | Unit does not come with return air filter.
ampair.co.uk | 01707 378 670 | [email protected]
69
PAC Systems
Indoor Unit
PAC Systems
FDU High Static Ducted Hyper Inverter 3 Phase
Indoor Unit
Remote Controller inc. Time Clock
EFFICIENCY
FDU140VF
RC-E5
FDC100VSX
FDC125VSX
FDC140VSX
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 16.0)
kW
kW
9.5 - 8.0
11.8 - 10.0
13.2 - 10.5
Nominal Heating (Range)
kW
11.2 (4.0 - 16.0)
14.0 (4.0 - 18.0)
16.0 (4.0 - 20.0)
UK Heating
kW
11.4
14.3
16.3
5.19 - 4.10
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
UK Cooling (Total - Sensible)
A / A+
n/a
n/a
3.73 - 3.71
3.58 - 3.71
3.27 - 3.62
A/A
A/A
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDU125VF
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
280 - 1370 - 740
280 - 1370 - 740
280 - 1370 - 740
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
1300 - 970 - 370
kg
54.0 - 105.0
54.0 - 105.0
54.0 - 105.0
Indoor Unit Airflow Rate (L-H)
l/s
450 - 567
558 - 700
558 - 700
Static Pressure
Pa
60 - 200
60 - 200
60 - 200
rect. 1200 x 170
rect. 1200 x 170
rect. 1200 x 170
30 - 36 - 38 - 44
29 - 34 - 40 - 45
30 - 35 - 40 - 46
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
4.5 - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
Yes** - VP25 (25id 32od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.0 - 4.5
5.2 - 5.6
6.2 - 6.9
kW
2.68 - 3.02
3.49 - 3.77
4.28 - 4.42
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDU100VF1
Start - Max Run Current
A
5.0 - 16.0
5.0 - 18.0
5.0 - 19.0
Suggested Fuse Size
A
20 per phase
25 per phase
25 per phase
Indoor Unit
£971
£1,180
£1,215
Remote Controller
£63
£63
£63
Outdoor Unit
£2,240
£2,520
£2,848
Retail Price
£3,274
£3,763
£4,126
* 15m height difference if outdoor is below indoor | **Lift pump as standard, 600mm from the underside of the unit | Unit does not come with return air filter.
@amp_aircon |
amp-air-conditioning
70
PAC Systems
PAC Systems
FDEN Ceiling Suspended
FDEN Ceiling Suspended Indoor Unit
FDC71VNX Outdoor Unit
»» Available with a range of outdoors, offering high
»»
»»
»»
»»
SEERs and SCOPs
Extended pipe runs, up to 100m depending on
model
Suitable for replacement technology (see below)
Selected outdoor units with Blue Fin protection
Top, right or rear piping
Compatible Accessories
Part No.
Description
List
Price
RC-E5*
Wired remote controller with 7-day
time clock
£63
RC-EX1A
Premium wired touch screen
controller with 7-day time clock
£123
RCH-E3
Simplified wired remote controller
£106
RCN-E1R
Infrared remote controller kit for
FDEN
£72
RENE-E
Infrared remote controller kit for
FDE
£72
SC-ADNA-E
Superlink network adapter for
connection to central controllers
£106
PCZ006A043
CNT connector for remote on/off,
run/fault etc.
£10
FM-MRFVF
CNT indoor run fault adapter
(volt free)
£110
»» Only 210mm or 250mm high
»» Available with a range of infrared or hard wired
control options
»» Can connect to centralised controller via superlink
network (SC-ADNA-E adapter required)
»» Available in twin, triple and quad system (see page
86 for details)
Existing
Pipe Sizes
Liquid Gas
Allowable Outdoors
Standard
Inverter VNP
Micro Inverter
VN & VS
Hyper Inverter
ZMX-S, VNX
& VSX
1/4"
1/2"
71
40-50-60
1/4"
5/8"
71
71-100-125-140
3/8"
1/2"
71
3/8"
5/8"
71-100
3/8"
3/4"
1/2"
5/8"
1/2"
3/4"
100
40-50-60-71
100-125-140
71-100-125-140
100-125-140
100-125-140
100-125-140
71-100-125-140
100-125-140
100-125-140
Subject to the pipe sizes used and selected outdoor unit additional pipe work and
capacity, limitations may apply.
Contact AMP for details.
*Included in system price as standard. See page 173 for other controls and
accessories.
ampair.co.uk | 01707 378 670 | [email protected]
71
PAC Systems
FDEN Ceiling Suspended Standard Inverter
Indoor Unit
FDEN71VF1
Remote Controller inc. Time Clock
EFFICIENCY
7.1 (1.4 - 7.1)
10.0 (2.8 - 11.2)
kW
kW
6.9 - 5.2
9.38 - 8.00
Nominal Heating (Range)
kW
7.1 (1.0 - 7.1)
11.2 (2.5 - 12.5)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC100VNP
UK Cooling (Total - Sensible)
5.2
7.30
5.70 - 4.00
6.63 - 4.25
A+ / A+
A++ / A+
2.84 - 3.62
3.76 - 3.81
C/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC71VNP
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
A/A
46 to -15
°C
Operating Range Heat
20 to -15
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
210 - 1320 - 690
250 - 1620 - 690
Outdoor Unit Dim. (H-W-D)
mm
640 - 800 (+71) - 290
845 - 970 - 370
kg
37 - 45
43 - 70
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
200 - 233 - 267 - 333
275 - 350 - 433 - 533
Static Pressure
Pa
0
0
n/a
n/a
38 - 39 - 41 - 50
34 - 38 - 43 - 48
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
54 - 54
57 - 61
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"*
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
Pre-Charged for
m
15
15
Charge R410A (Factory - Additional)
kg
1.6kg - 20g/m
2.55kg - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
No - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
11.10 - 8.80
11.70 - 12.90
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDE100VG
RC-E5
kW
2.50 - 1.96
2.60 - 2.94
Start - Max Run Current
A
5.0 - 14.5
21
Suggested Fuse Size
A
16
25
Indoor Unit
£826
£1,123
Remote Controller
£63
£63
Power Cons. (Cool - Heat)
Outdoor Unit
£1,329
£1,536
Retail Price
£2,218
£2,722
* Outdoor includes 3/8" & 5/8" reducers for indoor unit connection.
@amp_aircon |
amp-air-conditioning
72
PAC Systems
FDEN Ceiling Suspended Micro Inverter Single Phase
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
FDEN140VF
RC-E5
FDC100VN
FDC125VN
FDC140VN
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
UK Cooling (Total - Sensible)
kW
9.4 - 6.8
11.8 - 8.2
12.7 - 8.5
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
5.43 - 3.91
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
A/A
n/a
n/a
3.51 - 3.86
2.81 - 3.43
2.41 - 3.25
C/B
E/C
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDEN125VF
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
250 - 1620 - 690
250 - 1620 - 690
250 - 1620 - 690
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
43 - 81
49 - 81
49 - 81
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
275 - 350 - 433 - 533
383 - 433 - 483 - 533
383 - 433 - 483 - 533
Static Pressure
Pa
0
0
0
n/a
n/a
n/a
34 - 38 - 43 - 48
43 - 44 - 46 - 50
43 - 44 - 46 - 50
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
No - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
12.5 - 12.7
19.5 - 17.9
25.2 - 21.6
V-Ph-Hz
Interconnecting Cables
POWER
FDE100VG
230 - 1 - 50
kW
2.85 - 2.90
4.45 - 4.08
5.80 - 4.92
Start - Max Run Current
A
5.0 - 24.0
5.0 - 24.0
5.0 - 24.0
Suggested Fuse Size
A
32
32
32
£1,123
£1,270
£1,521
£63
£63
£63
Power Cons. (Cool - Heat)
Indoor Unit
Remote Controller
Outdoor Unit
£1,665
£1,965
£2,245
Retail Price
£2,851
£3,298
£3,829
* 15m height difference if outdoor is below indoor.
ampair.co.uk | 01707 378 670 | [email protected]
73
PAC Systems
Indoor Unit
Remote Controller inc. Time Clock
PAC Systems
FDEN Ceiling Suspended Micro Inverter Three Phase
Indoor Unit
Remote Controller inc. Time Clock
EFFICIENCY
FDEN140VF
RC-E5
FDC100VS
FDC125VS
FDC140VS
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
kW
9.4 - 6.8
11.8 - 8.2
12.7 - 8.5
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
7.1
8.9
10.1
5.39 - 3.90
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
UK Cooling (Total - Sensible)
A/A
n/a
n/a
3.51 - 3.86
2.81 - 3.43
2.41 - 3.25
C/B
E/C
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDEN125VF
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
250 - 1620 - 690
250 - 1620 - 690
250 - 1620 - 690
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
43 - 83
49 - 83
49 - 83
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
275 - 350 - 433 - 533
383 - 433 - 483 - 533
383 - 433 - 483 - 533
Static Pressure
Pa
0
0
0
n/a
n/a
n/a
34 - 38 - 43 - 48
43 - 44 - 46 - 50
43 - 44 - 46 - 50
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
No - VP20 (20id 26od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.2 - 4.2
6.6 - 6.0
8.6 - 7.2
kW
2.85 - 2.90
4.45 - 4.08
5.80 - 4.92
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDE100VG
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20A per phase
20A per phase
20A per phase
£1,123
£1,270
£1,521
£63
£63
£63
Indoor Unit
Remote Controller
Outdoor Unit
£1,744
£1,976
£2,277
Retail Price
£2,930
£3,309
£3,861
* 15m height difference if outdoor is below indoor.
@amp_aircon |
amp-air-conditioning
74
PAC Systems
FDEN Ceiling Suspended Hyper Inverter Sgl. Phase
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
FDEN60VF
RC-E5
SRC40ZMX-S
SRC50ZMX-S
SRC60ZMX-S
4.0 (1.1 - 4.7)
5.0 (1.1 - 5.6)
5.6 (1.1 - 6.3)
kW
UK Cooling (Total - Sensible)
kW
3.8 - 3.0
4.8 - 3.3
5.4 - 4.6
Nominal Heating (Range)
kW
4.5 (0.6 - 5.4)
5.4 (0.6 - 6.3)
6.7 (0.6 - 7.1)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
3.7
4.5
5.6
6.14 - 3.81
5.83 - 3.81
5.72 - 3.80
A++ / A
A+ / A
A+ / A
3.92 - 4.09
3.27 - 3.70
3.15 - 3.58
A/A
B/B
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDEN50VF
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
43 to -15
°C
20 to -15
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
210 - 1070 - 690
210 - 1070 - 690
210 - 1320 - 690
Outdoor Unit Dim. (H-W-D)
mm
640 - 800 (+71) - 290
640 - 800 (+71) - 290
640 - 800 (+71) - 290
kg
28.0 - 45.0
28.0 - 45.0
37.0 - 45.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
117 - 150 - 167 - 183
117 - 150 - 167 - 183
200 - 233 - 267 - 333
Static Pressure
Pa
0
0
0
n/a
n/a
n/a
37 - 38 - 39 - 46
37 - 38 - 39 - 46
38 - 39 - 41 - 48
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
50 - 50
54 - 50
54 - 54
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
1/2" - 1/4"
1/2" - 1/4"
Pipe Limits (Max Run - Height Diff.)
m
30 - 20
30 - 20
30 - 20
Pre-Charged for
m
15
15
15
Charge R410A (Factory - Additional)
kg
1.5kg - 20g/m
1.5kg - 20g/m
1.5kg - 20g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
No - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
4.8 - 5.2
7.1 - 6.7
8.1 - 8.7
kW
1.02 - 1.10
1.53 - 1.46
1.78 - 1.87
Start - Max Run Current
A
5.0 - 12.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
16
20
20
Indoor Unit
£585
£677
£743
Remote Controller
£63
£63
£63
Power Supply (Outdoor)
V-Ph-Hz
Interconnecting Cables
POWER
FDEN40VF
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
Outdoor Unit
£880
£973
£1,102
Retail Price
£1,528
£1,713
£1,908
* 15m height difference if outdoor is below indoor | Top, right or rear piping.
ampair.co.uk | 01707 378 670 | [email protected]
75
PAC Systems
Indoor Unit
PAC Systems
FDEN Ceiling Suspended Hyper Inverter Sgl. Phase
Indoor Unit
FDEN71VF1
Remote Controller inc. Time Clock
EFFICIENCY
7.1 (3.2 - 8.0)
10.0 (4.0 - 11.2)
kW
kW
6.7 - 5.1
9.5 - 6.8
Nominal Heating (Range)
kW
8.0 (3.6 - 9.0)
11.2 (4.0 - 12.5)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC100VNX
UK Cooling (Total - Sensible)
5.6
10.1
4.67 - 3.80
5.89 - 4.18
B/A
A+ / A+
3.36 - 3.79
3.92 - 4.18
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC71VNX
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
A/A
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
210 - 1320 - 690
250 - 1620 - 690
Outdoor Unit Dim. (H-W-D)
mm
750 - 880 (+88) - 340
1300 - 970 - 370
kg
37.0 - 60.0
43.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
200 - 233 - 267 - 333
275 - 350 - 433 - 533
Static Pressure
Pa
0
0
n/a
n/a
38 - 39 - 41 - 50
34 - 38 - 43 - 48
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
51 - 48
48 - 50
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
2.95 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Yes
No - VP20 (20id 26od)
mm
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
9.4 - 9.4
11.3 - 11.8
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDE100VG
RC-E5
kW
2.11 - 2.11
2.55 - 2.68
Start - Max Run Current
A
5.0 - 17.0
5.0 - 24.0
Suggested Fuse Size
A
25
32
Indoor Unit
£826
£1,123
Remote Controller
£63
£63
Power Cons. (Cool - Heat)
Outdoor Unit
£1,546
£2,068
Retail Price
£2,435
£3,254
* 15m height difference if outdoor is below indoor | Top, right or rear piping.
@amp_aircon |
amp-air-conditioning
76
PAC Systems
FDEN Ceiling Suspended Hyper Inverter Sgl. Phase
FDEN125VF
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC140VNX
12.5 (5.0 - 14.0)
14.0 (5.0 - 16.0)
kW
UK Cooling (Total - Sensible)
kW
11.8 - 8.2
13.2 - 8.7
Nominal Heating (Range)
kW
14.0 (4.0 - 17.0)
16.0 (4.0 - 18.0)
UK Heating
kW
12.6
14.4
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
n/a
n/a
3.24 - 3.71
2.81 - 3.41
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC125VNX
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
C/B
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
250 - 1620 - 690
250 - 1620 - 690
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
kg
49.0 - 105.0
49.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
383 - 433 - 483 - 533
383 - 433 - 483 - 533
Static Pressure
Pa
0
0
n/a
n/a
43 - 44 - 46 - 50
43 - 44 - 46 - 50
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Yes
No - VP20 (20id 26od)
mm
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
17.1 - 16.7
22.1 - 20.8
Interconnecting Cables
POWER
FDEN140VF
RC-E5
kW
3.86 - 3.77
4.98 - 4.69
Start - Max Run Current
A
5.0 - 26.0
5.0 - 26.0
Suggested Fuse Size
A
32
32
£1,270
£1,521
£63
£63
Power Cons. (Cool - Heat)
Indoor Unit
Remote Controller
Outdoor Unit
£2,424
£2,722
Retail Price
£3,757
£4,306
* 15m height difference if outdoor is below indoor | Top, right or rear piping.
ampair.co.uk | 01707 378 670 | [email protected]
77
PAC Systems
Indoor Unit
PAC Systems
FDEN Ceiling Suspended Hyper Inverter 3 Phase
Indoor Unit
Remote Controller inc. Time Clock
EFFICIENCY
FDEN140VF
RC-E5
FDC100VSX
FDC125VSX
FDC140VSX
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 16.0)
kW
kW
9.5 - 6.8
11.8 - 8.2
13.2 - 8.7
Nominal Heating (Range)
kW
11.2 (4.0 - 16.0)
14.0 (4.0 - 18.0)
16.0 (4.0 - 20.0)
UK Heating
kW
11.4
14.3
16.3
5.89 - 4.18
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
UK Cooling (Total - Sensible)
A+ / A+
n/a
n/a
3.92 - 4.18
3.24 - 3.71
2.81 - 3.41
A/A
C/B
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDEN125VF
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
250 - 1620 - 690
250 - 1620 - 690
250 - 1620 - 690
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
1300 - 970 - 370
kg
43.0 - 105.0
49.0 - 105.0
49.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
275 - 350 - 433 - 533
383 - 433 - 483 - 533
383 - 433 - 483 - 533
Static Pressure
Pa
0
0
0
n/a
n/a
n/a
43 - 44 - 46 - 50
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
34 - 38 - 43 - 48
43 - 44 - 46 - 50
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
4.5 - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
No - VP20 (20id 26od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
3.8 - 3.9
5.7 - 5.6
7.3 - 6.9
kW
2.55 - 2.68
3.86 - 3.77
4.98 - 4.69
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDE100VG
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20 per phase
20 per phase
20 per phase
£1,123
£1,270
£1,521
£63
£63
£63
Indoor Unit
Remote Controller
Outdoor Unit
£2,240
£2,520
£2,848
Retail Price
£3,426
£3,853
£4,432
* 15m height difference if outdoor is below indoor | Top, right or rear piping.
@amp_aircon |
amp-air-conditioning
78
PAC Systems
FDF Floor Standing
»» Available with a range of outdoors, offering high
SEERs and SCOPs
»» Small footprint and high capacity - ideal for comms
rooms applications
model
Suitable for replacement technology (see below)
Selected outdoor units with Blue Fin protection
Integral RC-E5 controller
Rear, left, right or bottom piping
Available with a range of infrared or hard wired
control options
»» Can connect to centralised controller via superlink
network (SC-ADNA-E adapter required)
»» Available in twin, triple and quad system (see page
86 for details)
»»
»»
»»
»»
»»
FDF Floor Standing Unit
FDC140VN Outdoor Unit
Compatible Accessories
Part No.
Description
List
Price
RC-E5*
Wired remote controller with 7-day
time clock
£63
RC-EX1A
Premium wired touch screen
controller with 7-day time clock
£123
RCH-E3
Simplified wired remote controller
£106
RCN-KIT3
Infrared remote controller kit
£166
SC-ADNA-E
Superlink network adapter for
connection to central controllers
£106
PCZ006A043
CNT connector for remote on/off,
run/fault etc.
£10
FM-MRFVF
CNT indoor run fault adapter
(volt free)
£110
Existing
Pipe Sizes
Liquid Gas
Allowable Outdoors
Standard
Inverter VNP
1/4"
1/2"
71
1/4"
5/8"
71
3/8"
1/2"
71
3/8"
5/8"
71-100
3/8"
3/4"
1/2"
5/8"
1/2"
3/4"
100
Micro Inverter
VN & VS
Hyper Inverter
ZMX-S, VNX
& VSX
71-100-125-140
71
100-125-140
71-100-125-140
100-125-140
100-125-140
100-125-140
71-100-125-140
100-125-140
100-125-140
Subject to the pipe sizes used and selected outdoor unit additional pipe work and
capacity, limitations may apply.
Contact AMP for details.
*Included in system price as standard. See page 173 for other controls and
accessories.
ampair.co.uk | 01707 378 670 | [email protected]
79
PAC Systems
»» Extended pipe runs, up to 100m depending on
PAC Systems
FDF Floor Standing Standard Inverter
Indoor Unit
FDF71VD1
Remote Controller inc. Time Clock
RC-E5
FDC71VNP
FDC100VNP
7.1 (1.4 - 7.1)
10.0 (2.8 - 11.2)
Nominal Cooling (Range)
kW
UK Cooling (Total - Sensible)
kW
6.9 - 5.0
9.38 - 7.66
Nominal Heating (Range)
kW
7.1 (1.0 - 7.1)
11.2 (2.5 - 12.5)
UK Heating
kW
EFFICIENCY
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
HYSICAL
AIRFLOW
SOUND
REFRIGERANT & PIPEWORK
5.2
7.30
5.24 - 3.91
5.41 - 3.94
A/A
A/A
2.70 - 3.41
3.13 - 3.62
D/B
Energy Label (Cool / Heat)
Operating Range Cool
B/A
46 to -15
°C
Operating Range Heat
20 to -15
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
1850 - 600 - 320
1850 - 600 - 320
Outdoor Unit Dim. (H-W-D)
mm
640 - 800 (+71) - 290
845 - 970 - 370
kg
49 - 45
52 - 61
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
233 - 267 - 300 - 333
317 - 383 - 433 - 483
Static Pressure
Pa
0
0
n/a
n/a
33 - 35 - 39 - 42
44 - 48 - 50 - 54
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
54 - 54
57 - 61
Pipe Sizes (Gas - Liquid)
in
1/2" - 1/4"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
23 - 20
23 - 20
Pre-Charged for
m
8
8
Charge R410A (Factory - Additional)
kg
1.6kg - 20g/m
2.55kg - 260g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
No - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
11.70 - 9.30
14.0 - 13.6
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDF100VD2
RC-E5
kW
2.63 - 2.08
3.19 - 3.09
Start - Max Run Current
A
5.0 - 14.5
21.0
Suggested Fuse Size
A
16
25
£1,435
£1,450
Included
Included
Power Cons. (Cool - Heat)
Indoor Unit
Remote Controller
Outdoor Unit
£1,329
£1,536
Retail Price
£2,764
£2,986
* Outdoor includes 3/8" & 5/8" reducers for indoor unit connection | Bottom, rear or side piping.
@amp_aircon |
amp-air-conditioning
80
PAC Systems
FDF Floor Standing Micro Inverter Single Phase
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
FDF140VD
RC-E5
FDC100VN
FDC125VN
FDC140VN
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
UK Cooling (Total - Sensible)
kW
9.4 - 7.6
11.8 - 8.6
13.2 - 9.3
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
8.0
10.0
11.4
5.02 - 3.80
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
B/A
n/a
n/a
3.21 - 3.61
2.81 - 3.21
2.72 - 3.01
C/C
D/D
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDF125VD
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
1850 - 600 - 320
1850 - 600 - 320
1850 - 600 - 320
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
52 - 81
52 - 81
52 - 81
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
317 - 383 - 433 - 483
317 - 383 - 433 - 483
317 - 383 - 433 - 483
Static Pressure
Pa
0
0
0
n/a
n/a
n/a
44 - 48 - 50 - 54
44 - 48 - 50 - 54
44 - 48 - 50 - 54
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
No - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
3 core + E
A
13.8 - 13.8
19.5 - 19.3
22.8 - 23.6
V-Ph-Hz
Interconnecting Cables
POWER
FDF100VD1
230 - 1 - 50
kW
3.12 - 3.10
4.40 - 4.36
5.15 - 5.31
Start - Max Run Current
A
5.0 - 24.0
5.0 - 24.0
5.0 - 24.0
Suggested Fuse Size
A
32
32
32
£1,450
£1,583
£1,709
Included
Included
Included
Power Cons. (Cool - Heat)
Indoor Unit
Remote Controller
Outdoor Unit
£1,665
£1,965
£2,245
Retail Price
£3,115
£3,548
£3,954
* 15m height difference if outdoor is below indoor.
ampair.co.uk | 01707 378 670 | [email protected]
81
PAC Systems
Indoor Unit
Remote Controller inc. Time Clock
PAC Systems
FDF Floor Standing Micro Inverter Three Phase
Indoor Unit
Remote Controller inc. Time Clock
EFFICIENCY
FDF140VD
RC-E5
FDC100VS
FDC125VS
FDC140VS
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
kW
9.4 - 7.6
11.8 - 8.6
13.2 - 9.3
Nominal Heating (Range)
kW
11.2 (4.0 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
UK Heating
kW
8.0
10.0
11.4
4.99 - 3.80
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
UK Cooling (Total - Sensible)
B/A
n/a
n/a
3.21 - 3.61
2.81 - 3.21
2.72 - 3.01
C/C
D/D
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDF125VD
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
Operating Range Cool
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
1850 - 600 - 320
1850 - 600 - 320
1850 - 600 - 320
Outdoor Unit Dim. (H-W-D)
mm
845 - 970 - 370
845 - 970 - 370
845 - 970 - 370
kg
52 - 83
52 - 83
52 - 83
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
317 - 383 - 433 - 483
317 - 383 - 433 - 483
317 - 383 - 433 - 483
Static Pressure
Pa
0
0
0
n/a
n/a
n/a
44 - 48 - 50 - 54
44 - 48 - 50 - 54
44 - 48 - 50 - 54
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
49 - 49
50 - 51
51 - 51
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
50 - 30*
50 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
3.8kg - 60g/m
3.8kg - 60g/m
3.8kg - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
No - VP20 (20id 26od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.6 - 4.6
6.5 - 6.5
7.6 - 7.9
kW
3.12 - 3.10
4.40 - 4.36
5.15 - 5.31
V-Ph-Hz
Interconnecting Cables
POWER
PAC Systems
PERFORMANCE
Outdoor Unit
FDF100VD1
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20A per phase
20A per phase
20A per phase
Indoor Unit
Remote Controller
£1,450
£1,583
£1,709
Included
Included
Included
Outdoor Unit
£1,744
£1,976
£2,277
Retail Price
£3,194
£3,559
£3,986
* 15m height difference if outdoor is below indoor.
@amp_aircon |
amp-air-conditioning
82
PAC Systems
FDF Floor Standing Hyper Inverter Single Phase
FDF71VD1
Remote Controller inc. Time Clock
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
FDC100VNX
7.1 (3.2 - 8.0)
10.0 (4.0 - 11.2)
kW
UK Cooling (Total - Sensible)
kW
6.7 - 4.9
9.4 - 7.6
Nominal Heating (Range)
kW
8.0 (3.6 - 9.0)
11.2 (4.0 - 12.5)
UK Heating
kW
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
5.6
10.1
4.80 - 3.81
5.20 - 3.80
B/A
A/A
3.21 - 3.62
3.53 - 3.68
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
RC-E5
FDC71VNX
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
A/A
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
1850 - 600 - 320
1850 - 600 - 320
Outdoor Unit Dim. (H-W-D)
mm
750 - 880 (+88) - 340
1300 - 970 - 370
kg
49.0 - 60.0
52.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
233 - 267 - 300 - 333
317 - 383 - 433 - 483
Static Pressure
Pa
0
0
n/a
n/a
33 - 35 - 39 - 42
44 - 48 - 50 - 54
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
51 - 48
48 - 50
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
50 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
2.95 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
No - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
9.8 - 9.9
12.6 - 13.5
Interconnecting Cables
POWER
FDF100VD1
RC-E5
kW
2.21 - 2.21
2.83 - 3.04
Start - Max Run Current
A
5.0 - 17.0
5.0 - 24.0
Suggested Fuse Size
A
25
32
£1,435
£1,450
Included
Included
Power Cons. (Cool - Heat)
Indoor Unit
Remote Controller
Outdoor Unit
£1,546
£2,068
Retail Price
£2,981
£3,518
* 15m height difference if outdoor is below indoor | Left right, bottom or rear piping.
ampair.co.uk | 01707 378 670 | [email protected]
83
PAC Systems
Indoor Unit
PAC Systems
FDF Floor Standing Hyper Inverter Single Phase
Indoor Unit
FDF125VD
Remote Controller inc. Time Clock
RC-E5
FDC125VNX
FDC140VNX
12.5 (5.0 - 14.0)
14.0 (5.0 - 16.0)
PERFORMANCE
Outdoor Unit
Nominal Cooling (Range)
kW
UK Cooling (Total - Sensible)
kW
11.8 - 8.6
13.2 - 9.3
Nominal Heating (Range)
kW
14.0 (4.0 - 17.0)
16.0 (4.0 - 18.0)
UK Heating
kW
12.7
14.5
n/a
n/a
EFFICIENCY
SEER - SCOP (Cool - Heat)
ERP (Cool / Heat)
EER - COP (Cool - Heat)
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
REFRIGERANT & PIPEWORK
n/a
n/a
3.21 - 3.61
3.01 - 3.41
A/A
Energy Label (Cool / Heat)
Operating Range Cool
B/B
43 to -15
°C
Operating Range Heat
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
1850 - 600 - 320
1850 - 600 - 320
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
kg
52.0 - 105.0
52.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
317 - 383 - 433 - 483
317 - 383 - 433 - 483
Static Pressure
Pa
0
0
n/a
n/a
44 - 48 - 50 - 54
44 - 48 - 50 - 54
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
V-Ph-Hz
Running Current (Cool - Heat)
Yes
No - VP20 (20id 26od)
mm
230 - 1 - 50
230 - 1 - 50
3 core + E
3 core + E
A
17.3 - 17.2
20.6 - 20.8
Interconnecting Cables
POWER
PAC Systems
FDF140VD
RC-E5
kW
3.89 - 3.88
4.65 - 4.69
Start - Max Run Current
A
5.0 - 26.0
5.0 - 24.0
Suggested Fuse Size
A
32
32
£1,583
£1,709
Included
Included
Power Cons. (Cool - Heat)
Indoor Unit
Remote Controller
Outdoor Unit
£2,424
£2,722
Retail Price
£4,007
£4,431
* 15m height difference if outdoor is below indoor | Left right, bottom or rear piping.
@amp_aircon |
amp-air-conditioning
84
PAC Systems
FDF Floor Standing Hyper Inverter Three Phase
PERFORMANCE
Outdoor Unit
EFFICIENCY
AMBIENT
RANGE
PHYSICAL
AIRFLOW
SOUND
RC-E5
FDF140VD
RC-E5
FDC100VSX
FDC125VSX
FDC140VSX
10.0 (4.0 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 16.0)
kW
UK Cooling (Total - Sensible)
kW
9.4 - 7.6
11.8 - 8.6
13.2 - 9.3
Nominal Heating (Range)
kW
11.2 (4.0 - 16.0)
14.0 (4.0 - 18.0)
16.0 (4.0 - 20.0)
UK Heating
kW
11.1
13.9
15.9
5.17 - 3.80
n/a
n/a
ERP (Cool / Heat)
EER - COP (Cool - Heat)
Operating Range Cool
Operating Range Heat
A/A
n/a
n/a
3.53 - 3.68
3.21 - 3.61
3.01 - 3.41
A/A
B/B
A/A
Energy Label (Cool / Heat)
REFRIGERANT & PIPEWORK
FDF125VD
RC-E5
Nominal Cooling (Range)
SEER - SCOP (Cool - Heat)
43 to -15
°C
20 to -20
°C
Indoor (Grille) Unit Dimensions (H-W-D)
mm
1850 - 600 - 320
1850 - 600 - 320
1850 - 600 - 320
Outdoor Unit Dim. (H-W-D)
mm
1300 - 970 - 370
1300 - 970 - 370
1300 - 970 - 370
kg
52.0 - 105.0
52.0 - 105.0
52.0 - 105.0
Indoor Unit Airflow Rate (L-M-H-Ph)
l/s
317 - 383 - 433 - 483
317 - 383 - 433 - 483
317 - 383 - 433 - 483
Static Pressure
Pa
0
0
0
n/a
n/a
n/a
44 - 48 - 50 - 54
44 - 48 - 50 - 54
44 - 48 - 50 - 54
Weight (Indoor (Grille) - Outdoor)
Discharge Spigots
Indoor Sound Pressure (L-M-H-Ph)
dB(A)
Outdoor Sound Pressure (Cool-Heat)
dB(A)
48 - 50
48 - 50
49 - 52
Pipe Sizes (Gas - Liquid)
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Pipe Limits (Max Run - Height Diff.)
m
100 - 30*
100 - 30*
100 - 30*
Pre-Charged for
m
30
30
30
Charge R410A (Factory - Additional)
kg
4.5 - 60g/m
4.5 - 60g/m
4.5 - 60g/m
Yes
Yes
Yes
Suitable For Replacement Tech.
Lift Pump - Indoor Drain Connection
Power Supply (Outdoor)
Running Current (Cool - Heat)
Power Cons. (Cool - Heat)
No - VP20 (20id 26od)
mm
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
3 core + E
3 core + E
3 core + E
A
4.2 - 4.5
5.7 - 5.7
6.8 - 6.9
kW
2.83 - 3.04
3.89 - 3.88
4.65 - 4.69
V-Ph-Hz
Interconnecting Cables
POWER
FDF100VD1
Start - Max Run Current
A
5.0 - 15.0
5.0 - 15.0
5.0 - 15.0
Suggested Fuse Size
A
20 per phase
20 per phase
20 per phase
Indoor Unit
Remote Controller
£1,450
£1,583
£1,709
Included
Included
Included
Outdoor Unit
£2,240
£2,520
£2,848
Retail Price
£3,690
£4,103
£4,557
* 15m height difference if outdoor is below indoor | Left right, bottom or rear piping.
ampair.co.uk | 01707 378 670 | [email protected]
85
PAC Systems
Indoor Unit
Remote Controller inc. Time Clock
PAC Systems
PAC Systems
Micro Inverter | Twin, Triple & Quad Systems
Outdoor
Unit
Nom.
Cool/Heat
Phase
Branch Pipe
FDC100VN
10.0 / 11.2
1Ph
1 x DIS-WA1G
FDC100VS
10.0 / 11.2
3Ph
1 x DIS-WA1G
FDC125VN
12.5 / 14.0
1Ph
1 x DIS-WA1G
FDC125VS
12.5 / 14.0
3Ph
1 x DIS-WA1G
FDC125VN
12.5 / 14.0
1Ph
1 x DIS-WA1G
FDC125VS
12.5 / 14.0
3Ph
1 x DIS-WA1G
FDC140VN
14.0 / 16.0
1Ph
1 x DIS-WA1G
FDC140VS
14.0 / 16.0
3Ph
1 x DIS-WA1G
FDC140VN
14.0 / 16.0
1Ph
1 x DIS TA1G*
FDC140VS
14.0 / 16.0
3Ph
1 x DIS TA1G*
FDC200VSA
19.0 / 22.4
3Ph
1 x DIS-WB1G
FDC200VSA
19.0 / 22.4
3Ph
1 x DIS-WB1G
FDC200VSA
19.0 / 22.4
3Ph
1 x DIS-TB1G*
Indoor
Units
50 + 50
50 + 50
60 + 60
60 + 60
SRK Wall
Mounted
FDTC
Compact
Cassette
FDT
Cassette
FDUM
Ducted
FDEN Ceiling
Suspended
FDF Floor
Standing
Retail Price
Retail Price
Retail Price
Retail Price
Retail Price
Retail Price
EER
EER
EER
EER
EER
EER
COP
£3,427.00
3.68
3.92
£3,506.00
3.68
3.92
£3,799.00
2.94
3.26
£3,810.00
2.94
3.26
COP
£3,245.00
3.08
3.44
£3,324.00
3..08
3.44
£3,653.00
2.34
3.03
£3,664.00
2.34
3.03
3.40
3.62
£3,729.00
3.16
3.78
£3,740.00
3.16
3.78
3.52
3.34
3.21
£3,318.00
3.52
3.34
3.21
TBC
2.96
3.44
2.96
£4,123.00
71 + 71
3.10
£4,800.00
3.09
3.95
£4,832.00
3.09
3.95
£4,527.00
3.02
£4,559.00
3.02
£5,176.00
TBC
3.54
TBC
71 + 125
71 + 71 + 71
3.54
3.49
£4,686.00
3.01
3.46
£4,718.00
3.01
3.46
£5,382.00
3.04
3.72
TBC
£4,115.00
2.93
3.16
3.89
TBC
2.87
£4,147.00
2.93
3.48
2.87
2.87
3.19
£5,260.00
2.71
3.19
3.49
£4,484.00
3.11
2.87
£5,692.00
2.92
3.49
£5,228.00
2.71
£4,452.00
3.11
£4,550.00
3.01
3.49
£4,105.00
£4,518.00
3.01
TBC
£4,073.00
3.48
3.49
£5,508.00
3.71
2.95
3.57
£6,099.00
2.82
3.49
£5,358.00
TBC
£5,767.00
3.66
£3,655.00
£5,201.00
TBC
3.66
£3,644.00
TBC
TBC
3.49
3.21
£3,638.00
TBC
£4,091.00
3.10
3.21
£3,627.00
3.44
£3,608.00
3.23
COP
£3,274.00
£3,597.00
3.23
COP
£3,195.00
£3,742.00
71 + 71
100 + 100
3.62
£3,430.00
TBC
50 + 71
50 + 50 + 50
3.40
COP
£3,239.00
£3,731.00
50 + 71
50 + 50 +50
COP
£3,351.00
TBC
£5,803.00
2.94
TBC
£5,740.00
3.64
2.98
3.72
*Assumes differential in branch pipes is less than 3m | System costs include all branch kits, 1 x RC-E5 controller (wall mounted systems include SC-BIKNE adapter for each
indoor, FDUM include filter and spigots kits | units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please
refer to technical data for exact values.
@amp_aircon |
amp-air-conditioning
86
PAC Systems
Outdoor
Unit
Nom.
Cool/Heat
Phase
Branch Pipe
FDC200VSA
19.0 / 22.4
3Ph
1x DIS-WB1G &
2 x DIS-WA1G
FDC250VSA
24.0 / 27.0
3Ph
1 x DIS-WB1G
FDC250VSA
24.0 / 27.0
3Ph
1 x DIS-TB1G*
FDC250VSA
24.0 / 27.0
3Ph
1 x DIS-TB1G*
FDC250VSA
24.0 / 27.0
3Ph
1x DIS-WB1G &
2 x DIS-WA1G
Indoor
Units
SRK Wall
Mounted
FDTC
Compact
Cassette
FDT
Cassette
FDUM
Ducted
FDEN Ceiling
Suspended
FDF Floor
Standing
Retail Price
Retail Price
Retail Price
Retail Price
Retail Price
Retail Price
EER
EER
EER
EER
EER
EER
COP
COP
£6,296.00
50 + 50 + 50
+ 50
2.73
3.21
COP
3.04
2.87
3.78
2.61
£6,227.00
TBC
2.88
3.59
2.80
TBC
£6,915.00
TBC
60 + 60 + 60
+ 60
2.16
2.80
TBC
TBC
3.95
2.62
3.18
TBC
£6,440.00
TBC
£7,067.00
3.23
3.48
£6,831.00
£6,421.00
£6,395.00
71 + 71 + 100
COP
3.09
£6,205.00
£6,357.00
60 + 60 + 125
COP
£6,196.00
3.64
£5,873.00
125 + 125
COP
£6,508.00
TBC
£6,863.00
2.90
3.77
*Assumes differential in branch pipes is less than 3m | System costs include all branch kits, 1 x RC-E5 controller (wall mounted systems include SC-BIKNE adapter for each
indoor, FDUM include filter and spigots kits | units must operate in the same mode at the same time | Capacities are for guidance only and based upon nominal ratings, please
refer to technical data for exact values.
Outdoor Unit Details & Pipe Sizing
Outdoor unit
Maximum Pipe Run
Pipe Sizes
FDC100VN
50m
5/8" & 3/8"
Suggested Fuse Size
32A
FDC100VS
50m
5/8" & 3/8"
20A per phase
FDC125VN
50m
5/8" & 3/8"
32A
20A per phase
FDC125VS
50m
5/8" & 3/8"
FDC140VN
50m
5/8" & 3/8"
32A
FDC140VS
50m
5/8" & 3/8"
20A per phase
FDC200VSA
70m
7/8" & 3/8**
32A per phase
FDC250VSA
70m
7/8" & 1/2"**
32A per phase
**If pipe run is greater than 35m increase gas pipe to 1 1/8”, if pipe run is greater than 40m increase liquid pipe to 1/2”.
Indoor Unit Pipe Sizing
Indoor Unit
Pipe Sizes
50
Depends on System
60
Depends on System
71
5/8" & 3/8"
100
5/8" & 3/8"
125
5/8" & 3/8"
Please refer to the technical manuals for detailed pipe sizing.
ampair.co.uk | 01707 378 670 | [email protected]
87
PAC Systems
Micro Inverter | Twin, Triple & Quad Systems
PAC Systems
PAC Systems
Hyper Inverter | Twin, Triple & Quad Systems
Outdoor
Unit
Nom.
Cool/Heat
Phase
Branch Pipe
FDC71VNX
7.1 / 8.0
1Ph
1 x DIS-WA1G
FDC100VNX
10.0 / 11.2
1Ph
1 x DIS-WA1G
FDC100VSX
10.0 / 11.2
3Ph
1 x DIS-WA1G
FDC125VNX
12.5 / 14.0
1Ph
1 x DIS-WA1G
FDC125VSX
12.5 / 14.0
3Ph
1 x DIS-WA1G
FDC125VNX
12.5 / 14.0
1Ph
1 x DIS-WA1G
FDC125VSX
12.5 / 14.0
3Ph
1 x DIS-WA1G
FDC140VNX
14.0 / 16.0
1Ph
1 x DIS-WA1G
FDC140VSX
14.0 / 16.0
3Ph
1 x DIS-WA1G
FDC140VNX
14.0 / 16.0
1Ph
1 x DIS TA1G*
FDC140VSX
14.0 / 16.0
3Ph
1 x DIS TA1G*
Indoor
Units
SRK Wall
Mounted
FDTC
Compact
Cassette
FDT
Cassette
FDUM
Ducted
FDEN Ceiling
Suspended
FDF Floor
Standing
Retail Price
Retail Price
Retail Price
Retail Price
Retail Price
Retail Price
EER
EER
EER
EER
EER
EER
COP
40 + 40
50 + 50
50 + 50
60 + 60
60 + 60
COP
£3,098.00
3.48
£3,830.00
3.76
4.31
£4,002.00
3.76
4.31
£4,258.00
3.47
4.02
£4,354.00
3.47
4.02
3.62
£3,648.00
3.14
3.50
£3,820.00
3.14
3.50
£4,112.00
3.05
3.41
£4,208.00
3.05
3.41
4.02
£3,754.00
3.91
4.21
£3,926.00
3.91
4.21
£4,188.00
4.08
4.35
£4,284.00
4.08
TBC
4.35
3.53
4.19
3.41
£3,642.00
3.76
3.71
3.31
3.71
3.31
TBC
3.83
3.61
3.83
3.08
4.32
71 + 71
3.61
£5,277.00
3.52
4.35
£5,403.00
3.52
4.35
£5,004.00
3.23
3.69
£5,130.00
3.23
3.69
4.32
£5,163.00
3.61
4.26
£5,289.00
3.61
4.26
3.78
3.08
3.78
£4,103.00
TBC
TBC
£4,199.00
TBC
£4,694.00
3.21
£4,182.00
TBC
£4,568.00
71 + 71
3.21
£4,086.00
£4,152.00
3.83
3.33
£3,770.00
£4,056.00
3.83
COP
£3,598.00
£3,814.00
3.76
COP
£2,892.00
£4,286.00
50 + 71
50 + 50 + 50
3.84
COP
£3,106.00
£4,190.00
50 + 71
50 + 50 + 50
COP
£3,044.00
TBC
£4,592.00
3.21
£4,550.00
3.68
2.82
£4,718.00
3.21
3.68
2.82
3.49
£5,705.00
2.90
3.22
£5,831.00
2.90
3.22
£4,929.00
3.41
2.86
£5,121.00
3.33
3.49
£4,676.00
£4,995.00
3.33
TBC
3.53
£5,055.00
3.41
2.86
3.53
* Assumes differential in branch pipes is less than 3m | System costs include all branch kits, 1 x RC-E5 controller (wall mounted systems include SC-BIKNE adapter for each
indoor, FDUM include filter and spigots kits | units must operate in the same mode at the same time). | Capacities are for guidance only and based upon nominal ratings, please
refer to technical data for exact values.
@amp_aircon |
amp-air-conditioning
88
PAC Systems
Hyper Inverter | Twin, Triple & Quad Systems
Outdoor Unit
Maximum Pipe Run
Pipe Sizes
Suggested Fuse Size
25A
FDC71VNX
50m
5/8" & 3/8"
FDC100VNX
100m
5/8" & 3/8"
32A
FDC100VSX
100m
5/8" & 3/8"
20A per phase
FDC125VNX
100m
5/8" & 3/8"
32A
20A per phase
FDC125VSX
100m
5/8" & 3/8"
FDC140VNX
100m
5/8" & 3/8"
32A
FDC140VSX
100m
5/8" & 3/8"
20A per phase
Indoor Unit Pipe Sizing
Indoor Unit
Pipe Sizes
50
Depends on System
60
Depends on System
71
5/8" & 3/8"
Please refer to the technical manuals for detailed pipe sizing.
Extended warranties,
reward points &
marketing cashback.
See page 183
ampair.co.uk | 01707 378 670 | [email protected]
89
PAC Systems
Outdoor Unit Details & Pipe Sizing
PAC Systems
CO2
Unique Efficiency
is an air-to-water heat pump which uses CO2 gas as
a natural refrigerant and delivers industry leading coefficient
performance of 4.3* with a minimal carbon footprint.
Q-ton is ideal for heating water up to temperatures of 90°C,
which is suitable for a wide range of applications. With a
Global Warming Potential (GWP) of 1 & Ozone Depletion
Potential (ODP) of 0, Q-ton is already future proven.
High
Performance
High
Efficiency
Environmentally
Responsible
Easy
Operation
Long-term
Reliability
For more information, please visit www.mhiae.com
call us on 0207 025 2772
on page 163
orSee
emailQ-Ton
[email protected]
*At 65°C water supply
@amp_aircon |
amp-air-conditioning
90
VRF
VRF Systems
ampair.co.uk | 01707 378 670 | [email protected]
91
VRF Systems
Overview
The Mitsubishi Heavy Industries range of VRF systems deliver high performance in both
cooling and heating modes for all commercial applications. They offer the highest level of
design flexibility, improved energy efficiency and enhanced operational functions.
offices. These are complimented by a wide range
of indoor units, available in 14 different styles and
12 capacities which ensures we can offer a flexible
solution to satisfy any kind of requirement.
The range is further enhanced by a comprehensive
range of control options. Local control can be
achieved via standard hardwired or infra-red
controllers whilst centralised control is also available
including touch screen or PC based controllers
with energy billing. In addition AMP can offer both
simple wiring interfaces or a full function interfaces
to ensure that all MHI VRF systems can be integrated
onto building management systems.
In addition an advanced design tool, E-Solutions is
available to all of our customers to aid the design
and selection process. E-Solutions simplifies the
selection process and enables engineers to select
the most cost-effective and energy efficient mix of
indoor units, outdoor units, pipework and controls. It
caters for both 2 and 3 pipe systems and is capable
of generating pipework schematics, wiring diagrams
and full product specifications.
VRF
An extensive range system types are available, from
small, single fan heat pump condensing units which
can serve up to 8 internal units, ideal for residential
applications. To large modular 2 and 3 pipe outdoor
units, with capacities up to 60HP / 168kW which
are ideal for large commercial buildings, hotels and
Our highly trained sales team have many years of
experience within the VRF market and they can help
you ensure the most optimal solution is selected.
Our sales team are supported by our sales and
technical teams based in Welwyn Garden City. They
have extensive product knowledge and experience
of MHI VRF systems and can offer design and
selection support along with on-site services such as
commissioning assistance.
@amp_aircon |
amp-air-conditioning
92
VRF Outdoor
Nominal Cooling kW
11.2 14.0 15.5 22.4 28.0 33.5 40.0 45.0 47.5 50.4 56.0 61.5 68.0 73.5 80.0 85.0
Nominal Heating kW
12.5 16.0 16.3 25.0 31.5 37.5 45.0 50.0 47.5 56.5 63.0 69.0 76.5 81.5 90.0 95.0
Outdoor Unit Type
112
140
155
224
280
335
400
450
475 504* 560
615 680* 735
800
850
4
5
6
8
10
12
14
16
17
18
20
22
24
26
28
30
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
Horse Power
95
MICRO KX6 1Ph - Heat Pump
ü
ü
ü
96 - 97
MICRO KX6 3Ph - Heat Pump
ü
ü
ü
98
LITE KXZP 3Ph - Heat Pump
99 - 109 NEW KXZ - Heat Pump
Page Number
110 - 116 KXR6 - Heat Recovery
ü
ü
ü
ü
ü
ü
ü
ü
ü
Nominal Cooling kW
90.0
96.0 101.0 106.5 113.0 118.0 123.5 130.0 136.0 142.5 145.0 150.0 156.0 162.0 168.0
Nominal Heating kW
100.0 108.0 113.0 119.5 127.0 132.0 138.0 142.0 146.0 159.0 162.0 168.0 175.0 182.0 189.0
Outdoor Unit Type
900
Horse Power
32
34
36
38
40
42
44
46
48
50
52
54
56
58
60
99 - 109 NEW KXZ - Heat Pump
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
110 - 116 KXR6 - Heat Recovery
ü
ü
ü
ü
ü
ü
ü
ü
ü
95
MICRO KX6 1Ph - Heat Pump
96 - 97
MICRO KX6 3Ph - Heat Pump
98
960* 1010* 1065* 1130* 1180* 1235* 1300 1360* 1425 1450 1500 1560 1620 1680
LITE KXZP 3Ph - Heat Pump
* - KXZ outdoor model sizes and capacities vary slightly.
Extended warranties,
reward points &
marketing cashback.
See page 183
ampair.co.uk | 01707 378 670 | [email protected]
93
VRF
Page Number
Overview
VRF Outdoor
Unit Look Up
The tables below will help you select the most
appropriate size outdoor unit depending on the
connected indoor units and required design indoor/
outdoor unit ratio.
VRF
Firstly, decide on the maximum allowable indoor/
outdoor ratio, which will depend on the application.
Please note, once 100% indoor/outdoor ratio is
exceeded, if all indoor units are operating at the
same time in the same mode, the indoor unit outputs
will reduce.
Secondly, read across until you come to the total
combined indoor unit capacity code. This will indicate
a suitable outdoor unit size.
Tables do not apply to Lite KXZP systems.
Indoor/
Outdoor Ratio
Not Exceeding
100
125
150
175
200
90%
4HP
5HP
8HP
8HP
8HP 10HP 10HP 12HP 12HP 14HP 14HP 16HP 16HP 18HP 18HP 20HP 20HP 22HP 22HP 24HP 24HP
Sum Of Indoor Unit Capacities Codes
225
250
275
300
325
350
375
400
425
450
475
500
525
550
575
600
95%
4HP
5HP
8HP
8HP
8HP 10HP 10HP 12HP 12HP 14HP 14HP 14HP 16HP 16HP 18HP 18HP 20HP 20HP 22HP 22HP 24HP
100%
4HP
5HP
6HP
8HP
8HP 10HP 10HP 10HP 12HP 12HP 14HP 14HP 14HP 16HP 16HP 18HP 18HP 20HP 20HP 22HP 22HP
105%
4HP
5HP
6HP
8HP
8HP
110%
4HP
5HP
5HP
8HP
8HP
8HP 10HP 10HP 10HP 12HP 12HP 14HP 14HP 14HP 16HP 16HP 18HP 18HP 18HP 20HP 20HP
115%
4HP
4HP
5HP
6HP
8HP
8HP
8HP 10HP 10HP 12HP 12HP 12HP 14HP 14HP 14HP 16HP 16HP 18HP 18HP 18HP 20HP
120%
4HP
4HP
5HP
6HP
8HP
8HP
8HP 10HP 10HP 10HP 12HP 12HP 12HP 14HP 14HP 14HP 16HP 16HP 18HP 18HP 18HP
8HP 10HP 10HP 12HP 12HP 12HP 14HP 14HP 16HP 16HP 18HP 18HP 18HP 20HP 20HP 22HP
125%
4HP
4HP
5HP
5HP
8HP
8HP
8HP
8HP 10HP 10HP 10HP 12HP 12HP 14HP 14HP 14HP 14HP 16HP 16HP 18HP 18HP
130%
4HP
4HP
5HP
5HP
6HP
8HP
8HP
8HP 10HP 10HP 10HP 12HP 12HP 12HP 14HP 14HP 14HP 16HP 16HP 16HP 18HP
LITE KXZP Outdoor units have a maximum indoor / outdoor ratio of 120%
Indoor/
Outdoor Ratio
Not Exceeding
90%
Sum Of Indoor Unit Capacities Codes
625
650
675
700
725
750
775
800
825
850
875
900
925
950
975 1000 1025 1050 1075 1100 1150
26HP 26HP 28HP 28HP 30HP 30HP 32HP 32HP 34HP 34HP 36HP 36HP 38HP 38HP 40HP 40HP 42HP 42HP 44HP 44HP 46HP
95%
24HP 26HP 26HP 28HP 28HP 28HP 30HP 30HP 32HP 32HP 34HP 34HP 36HP 36HP 38HP 38HP 40HP 40HP 42HP 42HP 44HP
100%
24HP 24HP 24HP 26HP 26HP 28HP 28HP 28HP 30HP 30HP 32HP 32HP 34HP 34HP 36HP 36HP 38HP 38HP 40HP 40HP 42HP
105%
22HP 24HP 24HP 24HP 26HP 26HP 28HP 28HP 28HP 30HP 30HP 32HP 32HP 34HP 34HP 34HP 36HP 36HP 38HP 38HP 40HP
110%
22HP 22HP 22HP 24HP 24HP 26HP 26HP 26HP 28HP 28HP 28HP 30HP 30HP 32HP 32HP 34HP 34HP 34HP 36HP 36HP 38HP
115%
20HP 22HP 22HP 22HP 24HP 24HP 24HP 26HP 26HP 28HP 28HP 28HP 30HP 30HP 30HP 32HP 32HP 34HP 34HP 34HP 36HP
120%
20HP 20HP 22HP 22HP 22HP 24HP 24HP 24HP 26HP 26HP 26HP 28HP 28HP 28HP 30HP 30HP 32HP 32HP 32HP 34HP 34HP
125%
18HP 20HP 20HP 20HP 22HP 22HP 24HP 24HP 24HP 24HP 26HP 26HP 28HP 28HP 28HP 28HP 30HP 30HP 32HP 32HP 34HP
130%
18HP 18HP 20HP 20HP 20HP 22HP 22HP 24HP 24HP 24HP 24HP 26HP 26HP 26HP 28HP 28HP 28HP 30HP 30HP 30HP 32HP
Indoor/
Sum Of Indoor Unit Capacities Codes
Outdoor Ratio
Not Exceeding 1200 1250 1300 1350 1400 1450 1500 1550 1600 1650 1700 1750 1800 1850 1900 1950 2000 2050 2100 2150 2184
90%
48HP 50HP 52HP 54HP 56HP 58HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP
95%
46HP 48HP 50HP 50HP 54HP 56HP 58HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP
100%
44HP 46HP 46HP 48HP 50HP 52HP 54HP 56HP 58HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP
105%
42HP 44HP 46HP 46HP 48HP 50HP 52HP 54HP 56HP 58HP 58HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP
110%
40HP 42HP 44HP 44HP 46HP 48HP 50HP 50HP 54HP 54HP 56HP 58HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP
115%
38HP 40HP 42HP 42HP 44HP 46HP 48HP 48HP 50HP 52HP 54HP 56HP 58HP 58HP 60HP 60HP 60HP 60HP 60HP 60HP 60HP
120%
36HP 38HP 40HP 40HP 42HP 44HP 46HP 46HP 48HP 50HP 50HP 54HP 54HP 56HP 58HP 60HP 60HP 60HP 60HP 60HP 60HP
125%
34HP 36HP 38HP 40HP 40HP 42HP 44HP 46HP 46HP 48HP 48HP 50HP 52HP 54HP 56HP 56HP 58HP 60HP 60HP 60HP 60HP
130%
34HP 36HP 36HP 38HP 40HP 40HP 42HP 44HP 44HP 46HP 48HP 48HP 50HP 50HP 54HP 54HP 56HP 58HP 58HP 60HP 60HP
@amp_aircon |
amp-air-conditioning
94
VRF Outdoor
Micro KX6 Heat Pump Outdoor Units Sgl. Phase
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
FDC140KXEN6
n/a
n/a
FDC155KXEN6
n/a
112 - 4
140 - 5
155 - 6
Nominal Cooling
kW
11.2
14.0
15.5
Nominal Heating
kW
12.5
16.0
16.3
6
8
8
90 - 168
112 - 210
124 - 233
Maximum Number of Indoor Units
Min - Max Connected Capacity Code
4.00 - 4.33
3.36 - 3.71
3.29 - 3.72
SEER (Office Profile)
5.56
4.67
4.58
SCOP (Office Profile)
4.20
4.60
4.61
Number of Modules
1
1
1
EER - COP (Cool - Heat)
Size of Modules
HP
4HP
5HP
6HP
Height
mm
845
845
845
Width
mm
970
970
970
Depth
mm
370
370
370
Weight
kg
85
85
85
dB(A)
54.0
55.0
56.0
Airflow Rate
l/s
1250
1250
1250
Max External Static Pressure
Pa
0
0
0
Gas Pipe Size
in
5/8"
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
3/8"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
5.0
5.0
5.0
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
25
32
32
kW
2.80 - 2.89
4.17 - 4.31
4.71 - 4.38
Running Current (Cool - Heat)
A
13.5 - 14.1
20.6 - 21.5
23.6 - 21.9
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC112KXEN6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
5
5
5
£3,525
£3,778
£4,163
n/a
n/a
n/a
£3,525
£3,778
£4,163
For pipe work limitations see installation manual | 2 core non polar 1.5mm2 screened cable | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB.
ampair.co.uk | 01707 378 670 | [email protected]
95
VRF
Outdoor Unit
VRF Outdoor
Micro KX6 Heat Pump Outdoor Units Three Phase
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
n/a
n/a
112 - 4
140 - 5
155 - 6
kW
11.2
14.0
15.5
kW
12.5
16.0
16.3
6
8
8
90 - 168
112 - 210
124 - 233
Maximum Number of Indoor Units
4.00 - 4.33
3.36 - 3.71
3.29 - 3.72
SEER (Office Profile)
5.56
4.67
4.58
SCOP (Office Profile)
5.11
5.35
5.41
Number of Modules
1
1
1
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
EER - COP (Cool - Heat)
REFRIGERANT &
PIPEWORK
FDC155KXES6
Nominal Heating
Size of Modules
HP
4HP
5HP
6HP
Height
mm
845
845
845
Width
mm
970
970
970
Depth
mm
370
370
370
Weight
kg
87
87
87
dB(A)
54.0
55.0
56.0
Airflow Rate
l/s
1250
1250
1250
Max External Static Pressure
Pa
0
0
0
Gas Pipe Size
in
5/8"
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
3/8"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
5.0
5.0
5.0
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
10
10
10
kW
2.80 - 2.89
4.17 - 4.31
4.71 - 4.38
Running Current (Cool - Heat)
A
4.5 - 4.7 per phase
6.9 - 7.2 per phase
7.8 - 7.3 per phase
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC140KXES6
n/a
Nominal Cooling
Min - Max Connected Capacity Code
VRF
FDC112KXES6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
5
5
5
£3,525
£3,778
£4,163
n/a
n/a
n/a
£3,525
£3,778
£4,163
For pipe work limitations see installation manual | 2 core non polar 1.5mm2 screened cable | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB.
@amp_aircon |
amp-air-conditioning
96
VRF Outdoor
Micro KX6 Heat Pump Outdoor Units Three Phase
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
PERFORMANCE
Capacity Code - Horse Power
FDC280KXE6
n/a
n/a
FDC335KXE6
n/a
224 - 8
280 - 10
335 - 12
Nominal Cooling
kW
22.4
28.0
33.5
Nominal Heating
kW
25.0
31.5
37.5
15
19
22
Min - Max Connected Capacity Code
112 - 336
140 - 420
168 - 503
EER - COP (Cool - Heat)
Maximum Number of Indoor Units
4.00 - 4.15
3.46 - 3.84
3.41 - 3.71
SEER (Office Profile)
TBC
TBC
TBC
SCOP (Office Profile)
TBC
TBC
TBC
Number of Modules
1
1
1
Size of Modules
HP
8HP
10HP
12HP
Height
mm
1675
1675
1675
Width
mm
1080
1080
1080
Depth
mm
480
480
480
Weight
kg
221
221
224
dB(A)
58.0
60.0
61.0
Airflow Rate
l/s
3333
3333
3333
Max External Static Pressure
Pa
0
0
0
Gas Pipe Size
in
3/8"
3/8"
1/2"
Liquid Pipe Size
in
3/4"
7/8"
1 1/8"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
11.5
11.5
11.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
16A
20A
25A
kW
5.60 - 6.03
8.09 - 8.21
9.82 - 10.12
Running Current (Cool - Heat)
A
9.25 - 9.85 per phase
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC224KXE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
13.22 - 13.41 per phase 15.87 - 16.36 per phase
5
5
5
£6,609
£7,311
£8,740
n/a
n/a
n/a
£6,609
£7,311
£8,740
For pipe work limitations see installation manual | 2 core non polar 1.5mm2 screened cable | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C
WB | When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130%.
ampair.co.uk | 01707 378 670 | [email protected]
97
VRF
Outdoor Unit
Connection Kit
VRF Outdoor
LITE KXZP Heat Pump Outdoor Units
Outdoor Unit
FDC224KXZPE1
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
280 - 10
kW
22.4
28.0
Nominal Heating
kW
22.4
28.0
8
8
Min - Max Connected Capacity Code
112 - 268
140 - 336
EER - COP (Cool - Heat)
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
n/a
224 - 8
Nominal Cooling
4.00 - 4.67
3.50 - 4.33
SEER (Office Profile)
TBC
TBC
SCOP (Office Profile)
TBC
TBC
Number of Modules
1
1
Size of Modules
HP
8HP
10HP
Height
mm
1505
1505
Width
mm
970
970
Depth
mm
370
370
Weight
kg
165
165
dB(A)
73.0
76.0
Airflow Rate
l/s
2167
2417
Max External Static Pressure
Pa
35
35
Gas Pipe Size
in
TBC
TBC
Liquid Pipe Size
in
3/8"
3/8"
Discharge Pipe Size
in
n/a
n/a
R410A Refrigerant Base Charge
kg
8.9
8.9
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
A
25A
25A
kW
5.60 - 4.80
8.00 - 6.47
Running Current (Cool - Heat)
A
8.80 - 7.50
12.30 - 10.00
Starting Current - Max. Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
VRF
FDC280KXZPE1
n/a
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
5 - 21
5 - 22
£5,420
£5,995
n/a
n/a
£5,420
£5,995
For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened
cable (2mm2 after 1000m total length).
@amp_aircon |
amp-air-conditioning
98
VRF Outdoor
KXZ Heat Pump Outdoor Units
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
PERFORMANCE
Capacity Code - Horse Power
FDC335KXZE1
n/a
n/a
FDC400KXZE1
n/a
280 - 10
335 - 12
400 - 14
Nominal Cooling
kW
28.0
33.5
40.0
Nominal Heating
kW
31.5
37.5
45.0
24
29
34
Min - Max Connected Capacity Code
140 - 364
168 - 435
200 - 520
EER - COP (Cool - Heat)
Maximum Number of Indoor Units
3.87 - 4.33
3.87 - 4.33
3.87 - 4.33
SEER (Office Profile)
TBC
TBC
TBC
SCOP (Office Profile)
TBC
TBC
TBC
Number of Modules
1
1
1
Size of Modules
HP
10HP
12HP
14HP
Height
mm
1690
1690
2048
Width
mm
1350
1350
1350
Depth
mm
720
720
720
Weight
kg
272
272
317
dB(A)
55.0
61.0
60.0
Airflow Rate
l/s
3667
4667
4667
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
7/8"
7/8"
1 1/8"
Liquid Pipe Size
in
3/8"
1/2"
1/2"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
11.0
11.0
11.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
25A
25A
32A
kW
7.24 - 7.28
8.96 - 9.04
10.96 - 10.69
Running Current (Cool - Heat)
A
11.9 - 12.0
14.6 - 14.8
17.5 - 17.5
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC280KXZE1
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
5
5
5
£7,973
£9,400
£10,180
n/a
n/a
n/a
£7,973
£9,400
£10,180
For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened
cable (2mm2 after 1000m total length).
ampair.co.uk | 01707 378 670 | [email protected]
99
VRF
Outdoor Unit
Connection Kit
VRF Outdoor
KXZ Heat Pump Outdoor Units
Outdoor Unit
FDC450KXZE1
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
475 - 17
kW
45.0
47.5
Nominal Heating
kW
50.0
53.0
39
41
Min - Max Connected Capacity Code
225 - 585
238 - 617
EER - COP (Cool - Heat)
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
n/a
450 - 16
Nominal Cooling
3.87 - 4.33
3.87 - 4.33
SEER (Office Profile)
TBC
TBC
SCOP (Office Profile)
TBC
TBC
Number of Modules
1
1
Size of Modules
HP
16HP
17HP
Height
mm
2048
2048
Width
mm
1350
1350
Depth
mm
720
720
Weight
kg
317
370
dB(A)
61.0
61.0
Airflow Rate
l/s
4667
4667
Max External Static Pressure
Pa
50
50
Gas Pipe Size
in
1 1/8"
1 1/8"
Liquid Pipe Size
in
1/2"
1/2"
Discharge Pipe Size
in
n/a
n/a
R410A Refrigerant Base Charge
kg
11.5
11.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
A
32A
50A
kW
13.98 - 12.50
13.98 - 13.00
Running Current (Cool - Heat)
A
22.4 - 20.4
22.6 - 21.0
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
VRF
FDC475KXZE1
n/a
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
5
8
£12,466
£12,970
n/a
n/a
£12,466
£12,970
For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened
cable (2mm2 after 1000m total length).
KXZ Hi COP
combinations
also available.
Contact AMP
for more
information.
@amp_aircon |
amp-air-conditioning
100
VRF Outdoor
KXZ Heat Pump Outdoor Units
FDC500KXZE1
Connection Kit
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
PERFORMANCE
Capacity Code - Horse Power
n/a
500 - 18
560 - 20
Nominal Cooling
kW
50.0
56.0
Nominal Heating
kW
56.0
63.0
43
48
Min - Max Connected Capacity Code
250 - 650
280 - 728
EER - COP (Cool - Heat)
Maximum Number of Indoor Units
3.87 - 4.33
TBC
SEER (Office Profile)
TBC
TBC
SCOP (Office Profile)
TBC
TBC
Number of Modules
1
1
Size of Modules
HP
18HP
20HP
Height
mm
2048
2048
Width
mm
1350
1350
Depth
mm
720
720
Weight
kg
370
370
dB(A)
61.0
64.0
Airflow Rate
l/s
4667
5167
Max External Static Pressure
Pa
50
50
Gas Pipe Size
in
1 1/8"
1 1/8"
Liquid Pipe Size
in
1/2"
1/2"
Discharge Pipe Size
in
n/a
n/a
R410A Refrigerant Base Charge
kg
11.5
11.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
A
50A
50A
kW
13.97 - 13.49
16.62 - 15.95
Running Current (Cool - Heat)
A
22.6 - 21.8
26.9 - 25.8
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC560KXZE1
n/a
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
8
8
£13,519
£14,060
n/a
n/a
£13,519
£14,060
For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened
cable (2mm2 after 1000m total length).
Extended warranties,
reward points &
marketing cashback.
See page 183
ampair.co.uk | 01707 378 670 | [email protected]
101
VRF
Outdoor Unit
VRF Outdoor
KXZ Heat Pump Outdoor Units
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
DOS-2A-3
615 - 22
670 - 24
735 - 26
61.5
67.0
73.5
Nominal Heating
kW
69.0
75.0
82.5
53
58
63
308 - 799
335 - 871
368 - 955
EER - COP (Cool - Heat)
TBC
TBC
TBC
SEER (Office Profile)
TBC
TBC
TBC
SCOP (Office Profile)
TBC
TBC
TBC
Number of Modules
2
2
2
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
FDC735KXZE1
DOS-2A-3
kW
Size of Modules
HP
10HP + 12HP
12HP + 12HP
12HP + 14HP
Height
mm
1690
1690
2048
Width**
mm
2720
2720
2720
Depth
mm
720
720
720
Weight
kg
544
544
589
dB(A)
55.0 & 61.0
61.0 & 61.0
61.0 & 60.0
Airflow Rate
l/s
8334
9334
9334
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 1/8"
1 1/8"
1 3/8"
Liquid Pipe Size
in
1/2"
1/2"
5/8"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
22.0
22.0
22.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
2 x 25A
2 x 25A
2 x 25A
kW
16.20 - 16.32
17.92 - 18.08
19.92 - 19.73
Running Current (Cool - Heat)
A
26.5 - 26.8
29.2 - 29.6
32.1 - 32.3
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC670KXZE1
DOS-2A-3
Nominal Cooling
Min - Max Connected Capacity Code
VRF
FDC615KXZE1
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
10
10
10
£17,373
£18,800
£19,580
£172
£172
£172
£17,545
£18,972
£19,752
** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
KXZ Hi COP
combinations
also available.
Contact AMP
for more
information.
@amp_aircon |
amp-air-conditioning
102
VRF Outdoor
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
FDC850KXZE1
DOS-2A-3
DOS-2A-3
800 - 28
850 - 30
Nominal Cooling
kW
80.0
85.0
Nominal Heating
kW
90.0
95.0
69
73
700 - 1040
425 - 1105
EER - COP (Cool - Heat)
TBC
TBC
SEER (Office Profile)
TBC
TBC
SCOP (Office Profile)
TBC
TBC
Number of Modules
2
2
Maximum Number of Indoor Units
Min - Max Connected Capacity Code
Size of Modules
HP
14HP + 14HP
14HP + 16HP
Height
mm
2048
2048
Width**
mm
2720
2720
Depth
mm
720
720
Weight
Kg
634
634
dB(A)
60.0 & 60.0
60.0 & 61.0
Airflow Rate
l/s
9334
9334
Max External Static Pressure
Pa
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
Liquid Pipe Size
in
5/8"
5/8"
Discharge Pipe Size
in
n/a
n/a
R410A Refrigerant Base Charge
kg
23.0
23.0
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
A
2 x 32A
2 x 32A
kW
21.92 - 21.38
24.94 - 23.19
Running Current (Cool - Heat)
A
35.0 - 35.0
39.9 - 37.9
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC800KXZE1
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
10
10
£20,360
£22,646
£172
£172
£20,532
£22,818
** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
ampair.co.uk | 01707 378 670 | [email protected]
103
VRF
KXZ Heat Pump Outdoor Units
VRF Outdoor
KXZ Heat Pump Outdoor Units
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
DOS-2A-3
900 - 32
950 - 34
1000 - 36
90.0
95.0
100.0
Nominal Heating
kW
100.0
106.0
112.0
78
80
80
450 - 1170
475 - 1235
500 - 1300
EER - COP (Cool - Heat)
TBC
TBC
TBC
SEER (Office Profile)
TBC
TBC
TBC
SCOP (Office Profile)
TBC
TBC
TBC
Number of Modules
2
2
2
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
FDC1000KXZE1
DOS-2A-3
kW
Size of Modules
HP
16HP + 16HP
17HP + 17HP
18HP + 18HP
Height
mm
2048
2048
2048
Width**
mm
2720
2720
2720
Depth
mm
720
720
720
Weight
kg
634
740
740
dB(A)
61.0 & 61.0
61.0 & 61.0
61.0 & 61.0
Airflow Rate
l/s
9334
9334
9334
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
1 3/8"
Liquid Pipe Size
in
5/8"
5/8"
5/8"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
23.0
23.0
23.0
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
2 x 32A
2 x 50A
2 x 50A
kW
27.96 - 25.00
27.96 - 26.00
27.94 - 26.98
Running Current (Cool - Heat)
A
44.8 - 40.8
45.2 - 42.0
45.2 - 43.6
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC950KXZE1
DOS-2A-3
Nominal Cooling
Min - Max Connected Capacity Code
VRF
FDC900KXZE1
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
10
16
16
£24,932
£25,940
£27,038
£172
£172
£172
£25,104
£26,112
£27,210
** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
KXZ Hi COP
combinations
also available.
Contact AMP
for more
information.
@amp_aircon |
amp-air-conditioning
104
VRF Outdoor
PERFORMANCE
Outdoor Unit
FDC1060KXZE1
FDC1120KXZE1
Connection Kit
DOS-2A-3
DOS-2A-3
Capacity Code - Horse Power
1060 - 38
1120 - 40
Nominal Cooling
kW
106.0
112.0
Nominal Heating
kW
119.0
126.0
80
80
530 - 1378
560 - 1456
EER - COP (Cool - Heat)
TBC
TBC
SEER (Office Profile)
TBC
TBC
SCOP (Office Profile)
TBC
TBC
Number of Modules
2
2
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
Min - Max Connected Capacity Code
Size of Modules
HP
18HP + 20HP
20HP + 20HP
Height
mm
2048
2048
Width**
mm
2720
2720
Depth
mm
720
720
Weight
kg
740
740
dB(A)
61.0 & 64.0
64.0 & 64.0
Airflow Rate
l/s
9834
10334
Max External Static Pressure
Pa
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
Liquid Pipe Size
in
3/4"
3/4"
Discharge Pipe Size
in
n/a
n/a
R410A Refrigerant Base Charge
kg
23.0
23.0
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
A
2 x 50A
2 x 50A
kW
30.59 - 29.44
33.24 - 31.90
Running Current (Cool - Heat)
A
49.5 - 47.6
53.8 - 51.6
Starting Current
A
Sound Pressure Level
Power Supply
POWER
Suggested Fuse Size
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
16
16
£27,579
£28,120
£172
£172
£27,751
£28,292
** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
Extended warranties,
reward points &
marketing cashback.
See page 183
ampair.co.uk | 01707 378 670 | [email protected]
105
VRF
KXZ Heat Pump Outdoor Units
VRF Outdoor
KXZ Heat Pump Outdoor Units
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
2 x DOS-3A-3
1200 - 42
1250 - 44
1300 - 46
120.0
125.0
130.0
Nominal Heating
kW
135.0
140.0
145.0
80
80
80
600 - 1560
625 - 1625
650 - 1690
EER - COP (Cool - Heat)
TBC
TBC
TBC
SEER (Office Profile)
TBC
TBC
TBC
SCOP (Office Profile)
TBC
TBC
TBC
Number of Modules
3
3
3
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
FDC1300KXZE1
2 x DOS-3A-3
kW
Size of Modules
HP
14HP + 14HP + 14HP
14HP + 14HP + 16HP
14HP + 16HP + 16HP
Height
mm
2048
2048
2048
Width**
mm
4090
4090
4090
Depth
mm
720
720
720
Weight
kg
951
951
951
dB(A)
60.0, 60.0 & 60.0
60.0, 60.0 & 61.0
60.0, 61.0 & 61.0
Airflow Rate
l/s
14000
14000
14000
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
1 3/8"
Liquid Pipe Size
in
3/4"
3/4"
3/4"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
34.5
34.5
34.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
3 x 32A
3 x 32A
3 x 32A
kW
32.88 - 32.07
35.90 - 33.88
38.92 - 35.69
Running Current (Cool - Heat)
A
52.5 - 52.5
57.4 - 55.4
62.3 - 58.3
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC1250KXZE1
2 x DOS-3A-3
Nominal Cooling
Min - Max Connected Capacity Code
VRF
FDC1200KXZE1
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
15
15
15
£30,540
£32,826
£35,112
£526
£526
£526
£31,066
£33,352
£35,638
.** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
KXZ Hi COP
combinations
also available.
Contact AMP
for more
information.
@amp_aircon |
amp-air-conditioning
106
VRF Outdoor
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
FDC1425KXZE1
FDC1450KXZE1
2 x DOS-3A-3
2 x DOS-3A-3
2 x DOS-3A-3
1350 - 48
1425 - 50
1450 - 52
Nominal Cooling
kW
135.0
142.5
145.0
Nominal Heating
kW
150.0
159.0
162.0
80
80
80
670 - 1755
713 - 1852
725 - 1885
EER - COP (Cool - Heat)
TBC
TBC
TBC
SEER (Office Profile)
TBC
TBC
TBC
SCOP (Office Profile)
TBC
TBC
TBC
Number of Modules
3
3
3
Maximum Number of Indoor Units
Min - Max Connected Capacity Code
Size of Modules
HP
16HP + 16HP + 16HP
17HP + 17HP + 17HP
17HP + 17HP + 18HP
Height
mm
2048
2048
2048
Width**
mm
4090
4090
4090
Depth
mm
720
720
720
Weight
kg
951
1110
1110
dB(A)
61.0, 61.0 & 61.0
61.0, 61.0 & 61.0
61.0, 61.0 & 61.0
Airflow Rate
l/s
14000
14000
14000
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
1 3/8"
Liquid Pipe Size
in
3/4"
3/4"
3/4"
Discharge Pipe Size
in
n/a
n/a
n/a
R410A Refrigerant Base Charge
kg
34.5
34.5
34.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
3 x 32A
3 x 50A
3 x 50A
kW
41.94 - 37.50
41.94 - 39.00
41.93 - 39.49
Running Current (Cool - Heat)
A
67.2 - 61.2
67.8 - 63.0
67.8 - 63.8
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC1350KXZE1
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
15
24
24
£37,398
£38,910
£39,459
£526
£526
£526
£37,924
£39,436
£39,985
** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
ampair.co.uk | 01707 378 670 | [email protected]
107
VRF
KXZ Heat Pump Outdoor Units
VRF Outdoor
KXZ Heat Pump Outdoor Units
Outdoor Unit
FDC1500KXZE1
FDC1560KXZE1
2 x DOS-3A-3
2 x DOS-3A-3
1500 - 54
1560 - 56
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
Nominal Cooling
kW
150.0
156.0
Nominal Heating
kW
168.0
175.0
80
80
750 - 1950
780 - 2028
EER - COP (Cool - Heat)
TBC
TBC
SEER (Office Profile)
TBC
TBC
SCOP (Office Profile)
TBC
TBC
Number of Modules
3
3
Maximum Number of Indoor Units
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
Size of Modules
HP
18HP + 18HP + 18HP
18HP + 18HP + 20HP
Height
mm
2048
2048
Width**
mm
4090
4090
Depth
mm
720
720
Weight
kg
1110
1110
dB(A)
61.0, 61.0 & 61.0
61.0, 61.0 & 64.0
Airflow Rate
l/s
14000
14500
Max External Static Pressure
Pa
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
Liquid Pipe Size
in
3/4"
3/4"
Discharge Pipe Size
in
n/a
n/a
R410A Refrigerant Base Charge
kg
34.5
34.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
A
3 x 50A
3 x 50A
kW
41.91 - 40.47
44.56 - 42.93
Running Current (Cool - Heat)
A
67.8 - 65.4
72.1 - 69.4
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
VRF
EFFICIENCY
Min - Max Connected Capacity Code
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
24
24
£40,557
£41,098
£526
£526
£41,083
£41,624
** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
KXZ Hi COP
combinations
also available.
Contact AMP
for more
information.
@amp_aircon |
amp-air-conditioning
108
VRF Outdoor
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
FDC1680KXZE1
2 x DOS-3A-3
2 x DOS-3A-3
1620 - 58
1680 - 60
Nominal Cooling
kW
162.0
168.0
Nominal Heating
kW
182.0
189.0
80
80
810 - 2106
840 - 2184
EER - COP (Cool - Heat)
TBC
TBC
SEER (Office Profile)
TBC
TBC
SCOP (Office Profile)
TBC
TBC
Number of Modules
3
3
Maximum Number of Indoor Units
Min - Max Connected Capacity Code
Size of Modules
HP
18HP + 20HP + 20HP
20HP + 20HP + 20HP
Height
mm
2048
2048
Width**
mm
4090
4090
Depth
mm
720
720
Weight
kg
1110
1110
dB(A)
61.0, 64.0 & 64.0
64.0, 64.0 & 64.0
Airflow Rate
l/s
15000
15500
Max External Static Pressure
Pa
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
Liquid Pipe Size
in
3/4"
3/4"
Discharge Pipe Size
in
n/a
n/a
R410A Refrigerant Base Charge
kg
34.5
34.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
A
3 x 50A
3 x 50A
kW
47.21 - 45.39
49.86 - 47.85
Running Current (Cool - Heat)
A
76.4 - 73.4
80.7 - 77.4
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC1620KXZE1
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
24
24
£41,639
£42,180
£526
£526
£42,165
£42,706
** Width allows for 20mm gap between modules | For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to
15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
ampair.co.uk | 01707 378 670 | [email protected]
109
VRF
KXZ Heat Pump Outdoor Units
VRF Outdoor
KXR6 Heat Recovery Outdoor Units
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
n/a
FDC335KXRE6
n/a
224 - 8
280 - 10
335 - 12
kW
22.4
28.0
33.5
Nominal Heating
kW
25.0
31.5
37.5
20
25
30
Min - Max Connected Capacity Code
112 - 448
140 - 560
167 - 670
EER - COP (Cool - Heat)
3.80 - 4.24
3.47 - 3.88
3.36 - 3.93
SEER (Office Profile)
4.42
4.27
4.64
SCOP (Office Profile)
3.82
3.74
4.31
Number of Modules
1
1
1
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
FDC280KXRE6
n/a
Nominal Cooling
Size of Modules
HP
8HP
10HP
12HP
Height
mm
1690
1690
1690
Width
mm
1350
1350
1350
Depth
mm
720
720
720
Weight
kg
252
252
256
dB(A)
57
59
62.5
Airflow Rate
l/s
3667
3667
4667
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
3/4"
7/8"
7/8"
Liquid Pipe Size
in
3/8"
3/8"
1/2"
Discharge Pipe Size
in
5/8"
3/4"
3/4"
R410A Refrigerant Base Charge
kg
8.7
9.9
11.4
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
25A
20A
25A
kW
5.90 - 5.90
8.08 - 8.11
9.98 - 9.55
Running Current (Cool - Heat)
A
9.1 - 9.2
12.9 - 12.8
15.9 - 15.5
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
VRF
FDC224KXRE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
5
5
5
£7,460
£8,323
£10,010
n/a
n/a
n/a
£7,460
£8,323
£10,010
When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130% | For pipe work limitations see installation manual | Operating
range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon |
amp-air-conditioning
110
VRF Outdoor
KXR6 Heat Recovery Outdoor Units
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
PERFORMANCE
Capacity Code - Horse Power
FDC450KXRE6
n/a
n/a
FDC504KXRE6
n/a
400 - 14
450 - 16
504 - 18
Nominal Cooling
kW
40.0
45.0
50.4
Nominal Heating
kW
45.0
50.0
56.5
36
40
36
Min - Max Connected Capacity Code
200 - 800
225 - 900
252 - 806
EER - COP (Cool - Heat)
3.45 - 3.77
3.34 - 3.75
3.32 - 3.74
SEER (Office Profile)
4.12
4.22
4.12
SCOP (Office Profile)
4.17
4.18
4.29
Number of Modules
1
1
1
Maximum Number of Indoor Units
Size of Modules
HP
14HP
16HP
18HP
Height
mm
1690
1690
2048
Width
mm
1350
1350
1350
Depth
mm
720
720
720
Weight
kg
337
337
361
dB(A)
60
62.5
62
Airflow Rate
l/s
4167
4333
4500
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 1/8"
1 1/8"
1 1/8"
Liquid Pipe Size
in
1/2"
1/2"
1/2"
Discharge Pipe Size
in
7/8"
7/8"
7/8"
R410A Refrigerant Base Charge
kg
11.5
11.5
11.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
25A
32A
32A
kW
11.61 - 11.93
13.49 - 13.32
15.18 - 15.12
Running Current (Cool - Heat)
A
19.0 - 19.9
21.6 - 22.0
23.8 - 25.2
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
FDC400KXRE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
8
8
8
£11,698
£13,250
£14,305
n/a
n/a
n/a
£11,698
£13,250
£14,305
When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130% | For pipe work limitations see installation manual | Operating
range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
ampair.co.uk | 01707 378 670 | [email protected]
111
VRF
Outdoor Unit
Connection Kit
VRF Outdoor
KXR6 Heat Recovery Outdoor Units
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
n/a
FDC680KXRE6
n/a
560 - 20
615 - 22
680 - 24
kW
56.0
61.5
68.0
Nominal Heating
kW
63.0
69.0
73.0
40
44
49
Min - Max Connected Capacity Code
280 - 896
308 - 984
340 - 1088
EER - COP (Cool - Heat)
3.12 - 3.75
2.86 - 3.61
2.62 - 3.71
SEER (Office Profile)
4.05
3.99
TBC
SCOP (Office Profile)
4.37
4.21
TBC
Number of Modules
1
1
1
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
FDC615KXRE6
n/a
Nominal Cooling
Size of Modules
HP
20HP
22HP
24HP
Height
mm
2048
2048
2048
Width
mm
1350
1350
1350
Depth
mm
720
720
720
Weight
kg
361
375
375
dB(A)
63.5
64.5
65.5
Airflow Rate
l/s
4500
4500
4500
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 1/8"
1 1/8"
1 1/8"
Liquid Pipe Size
in
1/2"
1/2"
1/2"
Discharge Pipe Size
in
7/8"
7/8"
7/8"
R410A Refrigerant Base Charge
kg
11.5
11.5
11.5
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
40A
40A
50A
kW
17.95 - 16.79
21.47 - 19.11
25.99 - 19.69
Running Current (Cool - Heat)
A
28.4 - 28.0
34.7 - 31.6
44.9 - 34.0
Starting Current
A
Sound Pressure Level
Power Supply
Suggested Fuse Size
POWER
VRF
FDC560KXRE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
8
8
8
£15,276
£16,865
£17,125
n/a
n/a
n/a
£15,276
£16,865
£17,125
When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130% | For pipe work limitations see installation manual | Operating
range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total length).
@amp_aircon |
amp-air-conditioning
112
VRF Outdoor
Outdoor Unit
Connection Kit
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
PERFORMANCE
Capacity Code - Horse Power
FDC800KXRE6
FDC850KXRE6
DOS-2A-1RG
DOS-2A-1RG
DOS-2A-1RG
735 - 26
800 - 28
850 - 30
Nominal Cooling
kW
73.5
80.0
85.0
Nominal Heating
kW
82.5
90.0
95.0
53
58
61
Min - Max Connected Capacity Code
368 - 1176
400 - 1280
425 - 1360
EER - COP (Cool - Heat)
3.49 - 3.87
3.45 - 3.77
3.39 - 3.76
SEER (Office Profile)
4.03
4.06
4.21
SCOP (Office Profile)
4.06
4.10
4.13
Number of Modules
2
2
2
Maximum Number of Indoor Units
Size of Modules
HP
12HP (-K) + 14HP
14HP + 14HP
14HP + 16HP
Height
mm
1690
1690
1690
Width**
mm
2720
2720
2720
Depth
mm
720
720
720
Weight
kg
674
674
674
dB(A)
59.0 & 60.0
60.0 & 60.0
60.0 & 62.5
Airflow Rate
l/s
7834
8334
8500
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
1 3/8"
Liquid Pipe Size
in
5/8"
5/8"
5/8"
Discharge Pipe Size
in
1 1/8"
1 1/8"
1 1/8"
Sound Pressure Level
kg
23
23
23
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
25A & 25A
25A & 25A
25A & 32A
kW
21.08 - 21.30
23.22 - 23.86
25.10 - 25.25
Running Current (Cool - Heat)
A
34.4 - 35.4
38.0 - 39.8
40.6 - 41.9
Starting Current
A
R410A Refrigerant Base Charge
Power Supply
Suggested Fuse Size
POWER
FDC735KXRE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
16
16
16
£22,681
£23,396
£24,948
£172
£172
£172
£22,853
£23,568
£25,120
When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130% | ** Width allows for 20mm gap between modules | For pipe
work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2
after 1000m total length).
ampair.co.uk | 01707 378 670 | [email protected]
113
VRF
KXR6 Heat Recovery Outdoor Units
VRF Outdoor
KXR6 Heat Recovery Outdoor Units
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
FDC1010KXRE6
DOS-2A-1RG
DOS-2A-1RG
900 - 32
960 - 34
1010 - 36
kW
90.0
96.0
101.0
Nominal Heating
kW
100.0
108.0
113.0
65
69
59
Min - Max Connected Capacity Code
450 - 1440
477 - 1526
504 - 1311
EER - COP (Cool - Heat)
3.34 - 3.75
3.35 - 3.80
3.32 - 3.74
SEER (Office Profile)
4.22
4.28
4.29
SCOP (Office Profile)
4.12
4.24
4.28
Number of Modules
2
2
2
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
FDC960KXRE6
DOS-2A-1RG
Nominal Cooling
Size of Modules
HP
16HP + 16HP
16HP + 18HP
18HP + 18HP
Height
mm
1690
2048
2048
Width**
mm
2720
2720
2720
Depth
mm
720
720
720
Weight
kg
674
698
722
dB(A)
62.5 & 62.5
62.5 & 62.0
62.0 & 62.0
Airflow Rate
l/s
8666
8833
9000
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
1 3/8"
Liquid Pipe Size
in
5/8"
5/8"
5/8"
Discharge Pipe Size
in
1 1/8"
1 1/8"
1 1/8"
Sound Pressure Level
kg
23
23
23
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
32A & 32A
32A & 32A
32A & 32A
kW
26.98 - 26.64
28.67 - 28.44
30.36 - 30.24
Running Current (Cool - Heat)
A
43.2 - 44.0
45.4 - 47.2
47.6 - 50.4
Starting Current
A
R410A Refrigerant Base Charge
Power Supply
Suggested Fuse Size
POWER
VRF
FDC900KXRE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
16
16
16
£26,500
£27,555
£28,610
£172
£172
£172
£26,672
£27,727
£28,782
* When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130% | ** Width allows for 20mm gap between modules | For pipe
work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2
after 1000m total length).
@amp_aircon |
amp-air-conditioning
114
VRF Outdoor
Outdoor Unit
Connection Kit
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
EFFICIENCY
PERFORMANCE
Capacity Code - Horse Power
FDC1130KXRE6
FDC1180KXRE6
DOS-2A-1RG
DOS-2A-1RG
DOS-2A-1RG
1065 - 38
1130 - 40
1180 - 42
Nominal Cooling
kW
106.5
113.0
118.0
Nominal Heating
kW
119.5
127.0
132.0
62
66
69
Min - Max Connected Capacity Code
532 - 1384
560 - 1456
588 - 1528
EER - COP (Cool - Heat)
3.21 - 3.74
3.15 - 3.78
2.99 - 3.68
SEER (Office Profile)
4.28
4.32
4.18
SCOP (Office Profile)
4.32
4.43
4.23
Number of Modules
2
2
2
Maximum Number of Indoor Units
Size of Modules
HP
18HP + 20HP
20HP + 20HP
20HP (-K) + 22HP
Height
mm
2048
2048
2048
Width**
mm
2720
2720
2720
Depth
mm
720
720
720
Weight
kg
722
722
750
dB(A)
62.0 & 63.5
63.5 & 63.5
63.5 & 64.5
Airflow Rate
l/s
9000
9000
9000
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
1 3/8"
Liquid Pipe Size
in
3/4"
3/4"
3/4"
Discharge Pipe Size
in
1 1/8"
1 1/8"
1 1/8"
Sound Pressure Level
kg
23
23
23
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
32A & 40A
40A & 40A
40A & 40A
kW
33.13 - 31.91
35.90 - 33.58
39.42 - 35.90
Running Current (Cool - Heat)
A
52.2 - 53.2
56.8 - 56.0
63.1 - 59.6
Starting Current
A
R410A Refrigerant Base Charge
Power Supply
Suggested Fuse Size
POWER
FDC1065KXRE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
16
16
16
£29,581
£30,552
£32,843
£172
£172
£172
£29,753
£30,724
£33,015
* When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130% | ** Width allows for 20mm gap between modules | For pipe
work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2
after 1000m total length).
Extended warranties,
reward points &
marketing cashback.
See page 183
ampair.co.uk | 01707 378 670 | [email protected]
115
VRF
KXR6 Heat Recovery Outdoor Units
VRF Outdoor
KXR6 Heat Recovery Outdoor Units
Outdoor Unit
Connection Kit
PERFORMANCE
Capacity Code - Horse Power
EFFICIENCY
PHYSICAL
SOUND &
AIRFLOW
FDC1360KXRE6
DOS-2A-1RG
DOS-2A-1RG
1235 - 44
1300 - 46
1360 - 48
kW
123.5
130.0
136.0
Nominal Heating
kW
138.0
142.0
146.0
72
76
80
Min - Max Connected Capacity Code
615 - 1599
650 - 1690
680 - 1768
EER - COP (Cool - Heat)
2.88 - 3.61
TBC
TBC
SEER (Office Profile)
4.08
TBC
TBC
SCOP (Office Profile)
4.57
TBC
TBC
Number of Modules
2
2
2
Maximum Number of Indoor Units
REFRIGERANT &
PIPEWORK
FDC1300KXRE6
DOS-2A-1RG
Nominal Cooling
Size of Modules
HP
22HP + 22HP
22HP + 24HP
24HP + 24HP
Height
mm
2048
2048
2048
Width**
mm
2720
2720
2720
Depth
mm
720
720
720
Weight
kg
750
750
798
dB(A)
64.5 & 64.5
64.5 & 65.5
65.5 & 65.5
Airflow Rate
l/s
9000
9000
9000
Max External Static Pressure
Pa
50
50
50
Gas Pipe Size
in
1 3/8"
1 3/8"
1 1/2"
Liquid Pipe Size
in
3/4"
3/4"
3/4"
Discharge Pipe Size
in
1 1/8"
1 1/8"
1 1/4"
Sound Pressure Level
kg
23
23
23
V-Ph-Hz
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
A
40A & 40A
40A & 50A
50A & 50A
kW
42.94 - 38.22
47.46 - 38.80
51.98 - 39.38
Running Current (Cool - Heat)
A
69.4 - 63.2
79.6 - 65.6
89.8 - 68.0
Starting Current
A
R410A Refrigerant Base Charge
Power Supply
Suggested Fuse Size
POWER
VRF
FDC1235KXRE6
Power Input (Cool - Heat)
Outdoor Unit
Connection Kit
Retail Price
16
16
16
£33,730
£33,990
£34,250
£172
£172
£172
£33,902
£34,162
£34,422
* When connecting indoor types FDK, FDFL,FDFU or FDFW the connectable capaity is limited to no more than 130% | ** Width allows for 20mm gap between modules | For pipe
work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C, heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2
after 1000m total length).
@amp_aircon |
amp-air-conditioning
116
VRF
Heating  Cooling  Hot Water Up To 90°C  Under Floor Heating  Heat Recovery Ventilation 
Combining Technologies
to provide highly efficient solutions
High
Performance
High
Efficiency
Environmentally
Responsible
Easy
Operation
Long-term
Reliability
This complete package delivers heating, cooling and sanitary hot water up to 90°C which allows maximum versatility and
also offers underfloor heating & ventilation. Mitsubishi Heavy Industries Air Conditioning Europe, Ltd is always striving to
deliver solution-driven & highly efficient systems for all modern building design requirements.
For further details email [email protected]
See KXZ onwww.mhiae.com
page 99 & Q-ton on page 163
ampair.co.uk | 01707 378 670 | [email protected]
117
VRF Outdoor
R22 Renew
Upgrade R22 VRF systems to R410A and keep the existing pipe work using the MHI Refresh KX system*.
»» Applies to a wide range of pipe sizes (R22, R407C,
R410A standard size)
»» Can be applied to all manufacturers existing
installation*
»» Saves time on renewal installation
»» Savings on replacement expenses such as
scrapping waste, procuring new pipe etc.
»» Possible to replace the existing unit with a new
larger capacity unit
»» Possible to replace multiple systems with one
VRF
system, e.g. 2 x existing 5HP units can be replaced
with 1 x new 10HP unit (see Figure 1).
»» Site survey required by AMP if system is nonoperational
Figure 1
Valve Box Unit
Oil Scavenge Sump
Replace old outdoor unit with new FDCR R410A
outdoor unit. 8HP & 10HP models are available with
the same output capacity as the old models but with
reduced physical size to ensure easiest installation.
Retain existing pipe work, subject to survey to ensure
pipe wall is think enough. Use old outdoor unit to
purge old oil and contaminants via valve box unit and
oil scavenge sump in just a few hours. The install new
outdoor unit and it will charge the system with the
new R410A refrigerant.
* The above procedure must be carried out in accordance with the manufacturers
instructions. Can be applied to other manufacturers existing systems, provided the
system is installed correctly and a survey has been carried out to ensure the existing
pipe work meets the standard met by MHI.
@amp_aircon |
amp-air-conditioning
118
VRF Outdoor
Refresh KX Outdoor Units
Connection Kit
n/a
Capacity Code - Horse Power
280
Nominal Cooling
kW
28.0
Nominal Heating
kW
31.5
EFFICIENCY
EER - COP (Cool - Heat)
TBC
SEER (Office Profile)
TBC
SCOP (Office Profile)
TBC
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
215mm
506mm
300mm
10.7kg
1
Number of Modules
Size of Modules
HP
10HP
Height
mm
1675
Width
mm
1080
Depth
mm
480
Weight
kg
224
dB(A)
60
Airflow Rate
l/s
3333
Max External Static Pressure
Pa
35
Gas Pipe Size
in
7/8" - 1 1/8"
Liquid Pipe Size
in
3/8" - 5/8"
Discharge Pipe Size
in
n/a
kg
11.5
V-Ph-Hz
400 - 3 - 50
R410A Refrigerant Base Charge
Power Supply
Pipe Refresh Kit
20
kW
8.09 - 8.21
Running Current (Cool - Heat)
A
13.22 - 13.41
Starting Current
A
Power Input (Cool - Heat)
Outdoor Unit
1283mm
404mm
602mm
Weight TBC
£7,312
5
£9,197
Connection Kit
Retail Price
£1,139
FDCR-KIT-E
A
Suggested Fuse Size
Service Valve Kit
140 - 364
Min - Max Connected Capacity Code
POWER
FDCR-V-KIT-E
16
Maximum Number of Indoor Units
Sound Pressure Level
Accessories for
systems where
existing units are
not operable
FDCR280KXE6
n/a
£9,197
For pipe work limitations see installation manual | Operating range (outdoor air), cooling -15°C to 43°C,
heating -20°C WB to 15.5°C WB | 2 core non polar 1.5mm2 screened cable (2mm2 after 1000m total
length).
Advanced Refresh Function
When the existing unit is operable
When the existing unit is not operable
If the existing system is operable, the existing pipe can be reused and
the pipe Refresh Kit and Service Valve Kit are not required.
The existing pipe can be reused by washing operation after connecting
Refresh KX, Pipe Refresh Kit and Service Valve Kit. Connecting and
removing of Refresh KX and Pipe Refresh Kit is very easy by use of
flexible pipe and flanges.
1. Implement cooling operation for all indoor units for more than 30
minutes
2. Implement pump-down after cooling operation
3. Recover refrigerant and remove the existing outdoor unit and indoor
unit
1. Pipe washing operation is implemented by changing dip switch on
the outdoor unit PCB
2. Complete washing is monitored via 7 segment display on the
outdoor unit PCB
3. As washing operation is about 60 minutes, it may mean a shorter
period of renewal installation
ampair.co.uk | 01707 378 670 | [email protected]
119
VRF
PERFORMANCE
Outdoor Unit
VRF Indoor
PFD Boxes & Branch Pipes
PFD Box
PFD1123-E
PFD1803-E
PFD2803-E
1
1
1
4
less than 11.2kW
less than 18.0kW
28.0kW or less
less than 44.8kW*
up to 16
Number Of Branches
Connectable Indoor Unit Capacity
PFD1123X4-E
1-5
1-8
1 -10
Height
mm
186
186
186
194
Width
mm
249
249
324
1000
Depth
mm
309
309
309
450
Weight
Kg
TBC
TBC
TBC
TBC
Indoor Side Connection Size
in
5/8"
5/8"
5/8"
5/8" x 4
Outdoor Side Connection Size
in
5/8" & 1/2"
5/8" & 1/2"
5/8" & 5/8"
7/8" & 5/8
Connectable Indoor Units
Brazed
Brazed
Brazed
Brazed
Power Supply
From Indoor
From Indoor
From Indoor
From Indoor
Retail Price
£416
£802
£906
VRF
Connection Type
£1,705
*(11.2kW per branch)
2 Pipe Branch Joints & Header Pipes
Model
Type
Description
DIS-22-1G
Branch Pipe Kit
Downstream capacity of less than 180
Retail Price
£92
DIS-180-1G
Branch Pipe Kit
Downstream capacity of 180 to 370
£92
DIS-371-1G
Branch Pipe Kit
Downstream capacity of 371 to 539
£95
DIS-540-2G
Branch Pipe Kit
Downstream capacity of 540 or more
£180
HEAD4-22-1G
4 Way Header
Downstream capacity of less than 180
£135
HEAD6-180-1G
6 Way Header
Downstream capacity of 180 to 370
£140
HEAD8-371-1G
8 Way Header
Downstream capacity of 371 to 539
£183
HEAD8-540-2G
8 Way Header
Downstream capacity of 540 or more
£216
Model
Type
Description
DIS-22-1RG
Branch Pipe Kit
Downstream capacity of less than 180
£120
DIS-180-1RG
Branch Pipe Kit
Downstream capacity of 180 to 370
£120
DIS-371-1RG
Branch Pipe Kit
Downstream capacity of 371 to 539
£125
DIS-540-2RG
Branch Pipe Kit
Downstream capacity of 540 or more
£204
3 Pipe Branch Joints
Retail Price
Outdoor Connection Kits
Model
Type
Description
DOS-2A-1G
Outdoor Connection Kit
For combined outdoor unit
£172
DOS-2A-3
Outdoor Connection Kit
For combined outdoor unit
£172
DOS-3A-3
Outdoor Connection Kit
For combined outdoor unit
£263
DOS-2A-1-RG
Outdoor Connection Kit
For combined outdoor unit
£172
@amp_aircon |
amp-air-conditioning
Retail Price
120
VRF Indoor
Overview
2.2
2.8
3.6
4.5
5.6
7.1
9.0
11.2
14.0
16.0
22.4
28.0
Nominal Heating kW
2.5
3.2
4.0
5.0
6.3
8.0
10.0
12.5
16.0
18.0
25.0
31.5
Indoor Unit Type
22
28
36
45
56
71
90
112
140
160
224
280
Capacity Code (HP)
22
28
36
45
56
71
90
112
140
160
224
280
124 - 125
1 Way Cassette
ü
ü
ü
ü
126 - 127
600mm2 Compact Cassette
ü
ü
ü
ü
ü
128 - 130
4 Way Cassette
ü
ü
ü
ü
ü
ü
ü
ü
ü
131 - 133
2 Way Cassette
ü
ü
ü
ü
ü
ü
ü
134 - 137
Standard Ducted
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
138 - 139
Low Static Ducted
ü
ü
ü
ü
ü
ü
140
Compact Ducted
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
141 - 143
High Static Ducted
144 - 145
Wall Mounted
146 - 147
Ceiling Suspended
148 - 149
Floor Standing Chassis
ü
ü
ü
ü
150 - 151
Floor Mounted Cabinet
ü
ü
ü
ü
154 - 155
Outdoor Air Processing Unit
156 - 157
SAF-DX Fresh Air Assembly
ü
ü
ü
ü
ü
ü
ü
ampair.co.uk | 01707 378 670 | [email protected]
ü
ü
121
VRF
Page Number
Nominal Cooling kW
VRF Indoor
UK Cooling Capacities
The unit capacities shown in this product guide are
nominal figures. The table below show approximate
UK cooling capacities at the following conditions.
Cooling design conditions: indoor 22°C DB 50% RH,
outdoor 30°C DB, high fan speed.
These figures are based upon KXR6 systems,
capacities for KX6 and KXZ systems will be similar.
reduce if the system diversity is over 100% and do
not take into account the following correction factors:
»» Correction factor for pipe work losses (length and
bends)
»» Correction factor for height difference
»» Correction factor for system connected indoor
units
The capacities shown are the maximum unit outputs
at the specified conditions. These capacities will
»» Correction factor for defrost cycle
»» Correction factor for indoor unit fan speed
22
28
36
45
56
71
Nominal Cooling
2.2
2.8
3.6
4.5
5.6
7.1
9
Nominal Heating
2.5
3.2
4
5
6.3
8
10
1 Way Cassette
(FDTQ & FDTS)
1.70
2.16
2.76
3.36
1.42
1.72
2.03
2.66
Compact Cassette
(FDTC)
1.68
2.13
2.75
3.48
4.35
1.61
1.85
2.37
2.80
3.40
4 Way Cassette
(FDT)
2.17
2.79
3.49
4.35
5.46
6.89
8.58
2.09
2.68
3.24
3.87
4.21
5.72
2 Way Cassette
(FDTW)
1.97
3.08
3.84
4.81
6.44
1.89
2.71
3.05
3.50
VRF
Unit Size
90
112
140
160
224
280
11.2
14
16
22.4
28
12.5
16
18
25
31.5
10.67
12.33
6.52
8.02
8.78
8.01
10.01
5.81
6.58
7.71
5.09
3.91
Standard Ducted
(FDUM)
1.72
2.19
2.81
3.45
4.25
5.45
7.00
8.63
10.89
12.44
1.65
2.10
2.45
2.74
3.12
4.61
5.34
6.91
8.70
9.57
Low Static Ducted
(FDUT)
1.74
2.21
2.85
3.56
4.43
5.61
1.44
1.75
2.17
2.76
3.35
4.24
Compact Ducted
(FDUH)
1.71
2.13
2.70
1.42
1.71
1.99
3.45
4.25
5.45
7.00
8.63
10.89
12.44
17.71
22.14
2.74
3.12
4.61
5.34
6.91
8.70
9.57
13.94
17.69
High Static Ducted
(FDU)
Wall Mounted
(FDK)
1.70
2.13
2.75
3.42
4.33
5.50
1.63
1.90
2.39
2.84
3.59
4.92
2.75
3.44
4.27
5.42
8.70
10.55
2.33
2.67
3.10
4.33
6.99
8.18
Ceiling Suspended
(FDE)
Floor Standing Chassis
(FDFU)
2.21
3.56
4.43
5.61
2.13
3.23
3.63
4.59
Floor Mounted Cabinet
(FDFW & FDFL)
2.21
3.56
4.43
5.61
1.98
2.61
3.22
4.59
Figures in grey are total cooling capacities, figures in blue are sensible cooling capacities.
@amp_aircon |
amp-air-conditioning
122
VRF Indoor
UK Heating Capacities
The unit capacities shown in this product guide are
nominal figures. The table below show approximate
UK cooling capacities at the following conditions.
Cooling design conditions: indoor 22°C DB 50% RH,
outdoor -4°C WB, high fan speed.
These figures are based upon KXR6 systems,
capacities for KX6 and KXZ systems will be similar.
reduce if the system diversity is over 100% and do
not take into account the following correction factors:
»» Correction factor for pipe work losses (length and
bends)
»» Correction factor for height difference
»» Correction factor for system connected indoor
units
The capacities shown are the maximum unit outputs
at the specified conditions. These capacities will
»» Correction factor for defrost cycle
»» Correction factor for indoor unit fan speed
22
28
36
45
56
71
90
Nominal Cooling
2.2
2.8
3.6
4.5
5.6
7.1
9
Nominal Heating
2.5
3.2
4
5
6.3
8
10
1 Way Cassette
(FDTQ & FDTS)
2.16
2.74
3.42
4.12
Compact Cassette
(FDTC)
2.11
2.69
3.36
4.31
5.41
4 Way Cassette
(FDT)
2.77
3.45
4.34
5.42
6.86
8.50
2 Way Cassette
(FDTW)
2.47
3.74
4.72
5.90
112
140
160
224
280
11.2
14
16
22.4
28
12.5
16
18
25
31.5
10.65
13.64
15.40
7.84
9.80
12.55
8.58
10.70
13.80
15.52
8.58
10.70
13.80
15.52
22.00
27.72
10.74
12.06
VRF
Unit Size
6.31
Standard Ducted
(FDUM)
2.16
2.77
3.46
4.25
5.34
6.81
Low Static Ducted
(FDUT)
2.20
2.82
3.52
4.40
5.28
7.04
Compact Ducted
(FDUH)
2.16
2.65
3.37
4.25
5.34
6.81
3.34
4.04
5.32
6.82
3.41
4.28
5.37
6.77
High Static Ducted
(FDU)
Wall Mounted
(FDK)
2.09
2.67
Ceiling Suspended
(FDE)
Floor Standing Chassis
(FDFU)
2.82
4.40
5.54
7.04
Floor Mounted Cabinet
(FDFW & FDFL)
2.82
4.40
5.54
7.04
ampair.co.uk | 01707 378 670 | [email protected]
123
VRF Indoor
PERFORMANCE
1 Way Cassettes
FDTQ22KXE6F
FDTQ28KXE6F
FDTQ36KXE6F
TQ-PSB-15W-E
TQ-PSB-15W-E
TQ-PSB-15W-E
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
22
28
36
2.2
2.8
3.6
Nominal Cooling
kW
Nominal Heating
kW
2.5
3.2
4.0
Height - Unit (Grille)
mm
250 (35)
250 (35)
250 (35)
Width - Unit (Grille)
mm
570 (625)
570 (625)
570 (625)
Depth - Unit (Grille)
mm
570 (650)
570 (650)
570 (650)
Weight - Unit (Grille)
kg
23 (2.5)
23 (2.5)
23 (2.5)
dB(A)
33 - 38 - 41 - 45
33 - 38 - 41 - 45
33 - 38 - 41 - 45
Airflow Rate (lo-me-hi-phi)
l/s
83 - 100 - 117 - 133
83 - 100 - 117 - 133
83 - 100 - 117 - 133
Static Pressure
Pa
n/a
n/a
n/a
Gas Pipe Size
in
3/8"
3/8"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP25 (25ID 32OD)
VP25 (25ID 32OD)
VP25 (25ID 32OD)
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.07 - 0.07
0.07 - 0.07
0.07 - 0.07
Running Current Cool - Heat
A
0.32 - 0.32
0.32 - 0.32
0.32 - 0.32
Starting Current
A
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
Indoor Unit
Grille
Power Input Cool - Heat
Less than 3A
Less than 3A
Less than 3A
Indoor Unit
£958
£980
£1,003
Grille
£145
£145
£145
£1,103
£1,125
£1,148
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600 from the underside of the ceiling tile |
Fresh air intake.
@amp_aircon |
amp-air-conditioning
124
VRF Indoor
Indoor Unit
FDTS45KXE6F
FDTS71KXE6F
Grille
TS-PSA-3AW-E
TS-PSA-3AW-E
Capacity Code
71
7.1
kW
Nominal Heating
kW
5.0
8.0
Height - Unit (Grille)
mm
220 (35)
220 (35)
Width - Unit (Grille)
mm
1150 (1250)
1150 (1250)
Depth - Unit (Grille)
mm
565 (650)
565 (650)
Weight - Unit (Grille)
kg
27 (5)
27 (5)
dB(A)
35 - 38 - 40 - 42
36 - 41 - 46 - 49
Airflow Rate (lo-me-hi-phi)
l/s
158 - 183 - 200 - 217
167 - 200 - 250 - 283
Static Pressure
Pa
n/a
n/a
Gas Pipe Size
in
1/2"
5/8"
Liquid Pipe Size
in
1/4"
3/8"
mm
VP25 (25ID 32OD)
VP25 (25ID 32OD)
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.04 - 0.04
0.09 - 0.09
Running Current Cool - Heat
A
0.27 - 0.27
0.60 - 0.60
Starting Current
A
Less than 3A
Less than 3A
£1,298
£1,454
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
45
4.5
Nominal Cooling
Power Input Cool - Heat
Indoor Unit
Grille
Retail Price
£163
£163
£1,461
£1,617
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600 from the underside of the ceiling tile |
Fresh air intake.
ampair.co.uk | 01707 378 670 | [email protected]
125
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
1 Way Cassettes
VRF Indoor
PERFORMANCE
4 Way Compact Cassettes
FDTC22KXE6F
FDTC28KXE6F
FDTC36KXE6F
Grille
TC-PSA-25W-W
TC-PSA-25W-W
TC-PSA-25W-W
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
22
28
36
2.2
2.8
3.6
Nominal Cooling
kW
Nominal Heating
kW
2.5
3.2
4.0
Height - Unit (Grille)
mm
248 (35)
248 (35)
248 (35)
Width - Unit (Grille)
mm
570 (700)
570 (700)
570 (700)
Depth - Unit (Grille)
mm
570 (700)
570 (700)
570 (700)
Weight - Unit (Grille)
kg
14 (3.5)
14 (3.5)
15 (3.5)
dB(A)
32 - 33 - 35 - 44
32 - 33 - 35 - 44
34 - 36 - 38 - 46
Airflow Rate (lo-me-hi-phi)
l/s
133 - 142 - 158 - 200
133 - 142 - 158 - 200
133 - 150 - 167 - 217
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
3/8"
3/8"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.03 - 0.03
0.03 - 0.03
0.03 - 0.03
Running Current Cool - Heat
A
0.10 - 0.10
0.10 - 0.10
0.11 - 0.11
Starting Current
A
Less than 3A
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
Indoor Unit
Power Input Cool - Heat
Less than 3A
Less than 3A
Indoor Unit
£853
£862
£905
Grille
£140
£140
£140
Retail Price
£993
£1,002
£1,045
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the underside of the ceiling tile | knock out for branch duct.
@amp_aircon |
amp-air-conditioning
126
VRF Indoor
Indoor Unit
FDTC45KXE6F
FDTC56KXE6F
Grille
TC-PSA-25W-W
TC-PSA-25W-W
Capacity Code
56
5.6
kW
Nominal Heating
kW
5.0
6.3
Height - Unit (Grille)
mm
248 (35)
248 (35)
Width - Unit (Grille)
mm
570 (700)
570 (700)
Depth - Unit (Grille)
mm
570 (700)
570 (700)
Weight - Unit (Grille)
kg
15 (3.5)
15 (3.5)
dB(A)
34 - 37 - 40 - 48
34 - 39 - 45 - 49
Airflow Rate (lo-me-hi-phi)
l/s
133 - 150 - 183 - 250
133 - 167 - 217 - 267
Static Pressure
Pa
0
0
Gas Pipe Size
in
1/2"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
mm
VP25 (25id 32od)
VP25 (25id 32od)
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.05 - 0.05
0.05 - 0.05
Running Current Cool - Heat
A
0.25 - 0.25
0.25 - 0.25
Starting Current
A
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
45
4.5
Nominal Cooling
Power Input Cool - Heat
Less than 3A
Less than 3A
Indoor Unit
£955
£1,053
Grille
£140
£140
£1,095
£1,193
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the underside of the ceiling tile | knock out for branch duct.
ampair.co.uk | 01707 378 670 | [email protected]
127
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
4 Way Compact Cassettes
VRF Indoor
PERFORMANCE
4 Way Cassettes
FDT28KXE6F
FDT36KXE6F
FDT45KXE6F
T-PSA-3BW-E
T-PSA-3BW-E
T-PSA-3BW-E
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
28
36
45
2.8
3.6
4.5
Nominal Cooling
kW
Nominal Heating
kW
3.2
4.0
5.0
Height - Unit (Grille)
mm
246 (35)
246 (35)
246 (35)
Width - Unit (Grille)
mm
840 (950)
840 (950)
840 (950)
Depth - Unit (Grille)
mm
840 (950)
840 (950)
840 (950)
Weight - Unit (Grille)
kg
22 (5.5)
22 (5.5)
22 (5.5)
dB(A)
30 - 31 - 33 - 37
30 - 31 - 33 - 37
30 - 31 - 33 - 37
Airflow Rate (lo-me-hi-phi)
l/s
233 - 267 - 300 - 333
233 - 267 - 300 - 333
233 - 267 - 300 - 333
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
3/8"
1/2"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Yes (700mm)*
Yes (700mm)*
Yes (700mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.03 - 0.03
0.03 - 0.03
0.03 - 0.03
Running Current Cool - Heat
A
0.15 - 0.15
0.15 - 0.15
0.15 - 0.15
Starting Current
A
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
Indoor Unit
Grille
Power Input Cool - Heat
Less than 3A
Less than 3A
Less than 3A
Indoor Unit
£905
£934
£1,004
Grille
£160
£160
£160
£1,065
£1,094
£1,164
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 700mm from the underside of the ceiling tile | Knock out for branch duct | Knock
out for fresh air intake.
@amp_aircon |
amp-air-conditioning
128
VRF Indoor
Indoor Unit
FDT56KXE6F
FDT71KXE6F
FDT90KXE6F
Grille
T-PSA-3BW-E
T-PSA-3BW-E
T-PSA-3BW-E
Capacity Code
71
90
7.1
9.0
kW
Nominal Heating
kW
6.3
8.0
10.0
Height - Unit (Grille)
mm
246 (35)
246 (35)
298 (35)
Width - Unit (Grille)
mm
840 (950)
840 (950)
840 (950)
Depth - Unit (Grille)
mm
840 (950)
840 (950)
840 (950)
Weight - Unit (Grille)
kg
24 (5.5)
24 (5.5)
27 (5.5)
dB(A)
30 - 31 - 33 - 39
30 - 31 - 33 - 46
35 - 37 - 40 - 51
Airflow Rate (lo-me-hi-phi)
l/s
233 - 267 - 300 - 333
233 - 267 - 300 - 467
333 - 400 - 617 - 617
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
1/2"
5/8"
5/8"
Liquid Pipe Size
in
1/4"
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Yes (700mm)*
Yes (700mm)*
Yes (700mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.04 - 0.04
0.08 - 0.08
0.15 - 0.15
Running Current Cool - Heat
A
0.20 - 0.20
0.40 - 0.40
0.76 - 0.76
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,075
£1,133
£1,261
£160
£160
£160
£1,235
£1,293
£1,421
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
56
5.6
Nominal Cooling
Power Input Cool - Heat
Indoor Unit
Grille
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 700mm from the underside of the ceiling tile | Knock out for branch duct | Knock
out for fresh air intake.
ampair.co.uk | 01707 378 670 | [email protected]
129
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
4 Way Cassettes
VRF Indoor
PERFORMANCE
4 Way Cassettes
FDT112KXE6F
FDT140KXE6F
FDT160KXE6F
Grille
T-PSA-3BW-E
T-PSA-3BW-E
T-PSA-3BW-E
112
140
160
11.2
14.0
16.0
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
Nominal Cooling
kW
Nominal Heating
kW
12.5
16.0
18.0
Height - Unit (Grille)
mm
298 (35)
298 (35)
298 (35)
Width - Unit (Grille)
mm
840 (950)
840 (950)
840 (950)
Depth - Unit (Grille)
mm
840 (950)
840 (950)
840 (950)
Weight - Unit (Grille)
kg
27 (5.5)
27 (5.5)
27 (5.5)
dB(A)
35 - 37 - 40 - 51
37 - 40 - 42 - 51
38 - 41 - 43 - 51
Airflow Rate (lo-me-hi-phi)
l/s
333 - 400 - 450 - 617
383 - 450 - 500 - 617
383 - 450 - 500 - 617
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
5/8"
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Yes (700mm)*
Yes (700mm)*
Yes (700mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.15 - 0.15
0.15 - 0.15
0.15 - 0.15
Running Current Cool - Heat
A
0.76 - 0.76
0.76 - 0.76
0.76 - 0.76
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,436
£1,627
£1,678
£160
£160
£160
£1,596
£1,787
£1,838
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
Indoor Unit
Power Input Cool - Heat
Indoor Unit
Grille
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 700mm from the underside of the ceiling tile | Knock out for branch duct | Knock
out for fresh air intake.
Optional RC-E5 hard wired controller
@amp_aircon |
amp-air-conditioning
130
VRF Indoor
Indoor Unit
FDTW28KXE6F
FDTW45KXE6F
FDTW56KXE6F
Grille
TW-PSA-26W-E
TW-PSA-26W-E
TW-PSA-26W-E
Capacity Code
45
56
4.5
5.6
kW
Nominal Heating
kW
3.2
5.0
6.3
Height - Unit (Grille)
mm
325 (20)
325 (20)
325 (20)
Width - Unit (Grille)
mm
820 (1120)
820 (1120)
820 (1120)
Depth - Unit (Grille)
mm
620 (680)
620 (680)
620 (680)
Weight - Unit (Grille)
kg
20 (8.5)
21 (8.5)
21 (8.5)
dB(A)
31 - 34 - 38 - 42
31 - 34 - 38 - 42
31 - 34 - 38 - 42
Airflow Rate (lo-me-hi-phi)
l/s
150 - 167 - 200 - 242
150 - 167 - 200 - 242
150 - 167 - 200 - 242
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
3/8"
1/2"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Yes (750mm)*
Yes (750mm)*
Yes (750mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.09 - 0.09
0.10 - 0.10
0.10 - 0.10
Running Current Cool - Heat
A
0.45 - 0.45
0.55 - 0.55
0.55 - 0.55
Starting Current
A
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
28
2.8
Nominal Cooling
Power Input Cool - Heat
Less than 3A
Less than 3A
Less than 3A
Indoor Unit
£999
£1,125
£1,218
Grille
£163
£163
£163
£1,162
£1,288
£1,381
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 750mm from the underside of the ceiling tile | Knock out for branch duct | Knock
out for fresh air intake.
ampair.co.uk | 01707 378 670 | [email protected]
131
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
2 Way Cassettes
VRF Indoor
PERFORMANCE
2 Way Cassettes
FDTW71KXE6F
FDTW90KXE6F
Grille
TW-PSA-26W-E
TW-PSA-46W-E
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
71
90
7.1
9.0
Nominal Cooling
kW
Nominal Heating
kW
8.0
10.0
Height - Unit (Grille)
mm
325 (20)
325 (20)
Width - Unit (Grille)
mm
820 (1120)
1535 (1835)
Depth - Unit (Grille)
mm
620 (680)
620 (680)
Weight - Unit (Grille)
kg
23 (8.5)
35 (13)
dB(A)
31 - 34 - 38 - 42
37 - 41 - 45 - 48
Airflow Rate (lo-me-hi-phi)
l/s
150 - 167 - 200 - 242
333 - 383 - 450 - 517
Static Pressure
Pa
0
0
Gas Pipe Size
in
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
Yes (750mm)*
Yes (750mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.14 - 0.14
0.19 - 0.19
Running Current Cool - Heat
A
0.75 - 0.75
1.00 - 1.00
Starting Current
A
Less than 3A
Less than 3A
£1,303
£1,491
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
Indoor Unit
Power Input Cool - Heat
Indoor Unit
Grille
Retail Price
£163
£163
£1,466
£1,654
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 750mm from the underside of the ceiling tile | Knock out for branch duct | Knock
out for fresh air intake.
@amp_aircon |
amp-air-conditioning
132
VRF Indoor
Indoor Unit
FDTW112KXE6F
FDTW140KXE6F
Grille
TW-PSA-46W-E
TW-PSA-46W-E
Capacity Code
140
11.2
14.0
Nominal Cooling
kW
Nominal Heating
kW
12.5
16.0
Height - Unit (Grille)
mm
325 (20)
325 (20)
Width - Unit (Grille)
mm
1535 (1835)
1535 (1835)
Depth - Unit (Grille)
mm
620 (680)
620 (680)
Weight - Unit (Grille)
kg
35 (13)
35 (13)
dB(A)
37 - 41 - 45 - 48
37 - 41 - 45 - 48
Airflow Rate (lo-me-hi-phi)
l/s
333 - 383 - 450 - 517
333 - 383 - 450 - 517
Static Pressure
Pa
0
0
Gas Pipe Size
in
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
Yes (750mm)*
Yes (750mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.19 - 0.19
0.19 - 0.19
Running Current Cool - Heat
A
1.00 - 1.00
1.00 - 1.00
Starting Current
A
Less than 3A
Less than 3A
£1,836
£1,940
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
112
Power Input Cool - Heat
Indoor Unit
Grille
Retail Price
£163
£163
£1,999
£2,103
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 750mm from the underside of the ceiling tile | Knock out for branch duct | Knock
out for fresh air intake.
Optional RC-EX1A hard wired controller
ampair.co.uk | 01707 378 670 | [email protected]
133
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
2 Way Cassettes
VRF Indoor
Standard Ducted
Indoor Unit
Spigot Kit
PERFORMANCE
Filter
REFRIGERANT &
PIPEWORK
FDUM28KXE6F
FDUM36KXE6F
AMP-FDUM-2
AMP-FDUM-2
AMP-FDUM-2
UM-FL1EF
UM-FL1EF
UM-FL1EF
22
28
36
3.6
Nominal Cooling
kW
2.2
2.8
Nominal Heating
kW
2.5
3.2
4.0
Height
mm
280
280
280
Width
mm
750
750
750
Depth
mm
635
635
635
Weight
kg
29
29
29
dB(A)
26 - 29 - 32 - 37
26 - 29 - 32 - 37
26 - 29 - 32 - 37
Airflow Rate (lo-me-hi-phi)
l/s
133 - 150 - 167 - 217
133 - 150 - 167 - 217
133 - 150 - 167 - 217
Static Pressure
Pa
100 @ 217l/s
100 @ 217l/s
100 @ 217l/s
Gas Pipe Size
in
3/8"
3/8"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP20 Standard
VP20 Standard
VP20 Standard
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.10 - 0.10
0.10 - 0.10
0.10 - 0.10
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
FDUM22KXE6F
Power Input Cool - Heat
Running Current Cool - Heat
A
0.46 - 0.46
0.46 - 0.46
0.46 - 0.46
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
Indoor Unit
£812
£840
£966
Spigot Kit
£40
£40
£40
Filter
£72
£72
£72
Retail Price
£924
£952
£1,078
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | As standard units come with rectangular air
outlets 660 x 200 (22-56), 860 x 200 (71-90), 1280 x 235 (112-160), the optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible
ductwork | No return air filter as standard.
@amp_aircon |
amp-air-conditioning
134
VRF Indoor
Indoor Unit
Spigot Kit
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Filter
Capacity Code
FDUM56KXE6F
FDUM71KXE6F
AMP-FDUM-2
AMP-FDUM-2
AMP-FDUM-3
UM-FL1EF
UM-FL1EF
UM-FL2EF
45
56
71
7.1
Nominal Cooling
kW
4.5
5.6
Nominal Heating
kW
5.0
6.3
8.0
Height
mm
280
280
280
Width
mm
750
750
950
Depth
mm
635
635
635
Weight
kg
29
29
34
dB(A)
26 - 29 - 32 - 37
26 - 29 - 32 - 37
25 - 29 - 33 - 38
Airflow Rate (lo-me-hi-phi)
l/s
133 - 150 - 167 - 217
133 - 150 - 167 - 217
167 - 250 - 317 - 400
Static Pressure
Pa
100 @ 217l/s
100 @ 217l/s
100 @ 400l/s
Gas Pipe Size
in
1/2"
1/2"
5/8"
Liquid Pipe Size
in
1/4"
1/4"
3/8"
mm
VP20 Standard
VP20 Standard
VP20 Standard
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.10 - 0.10
0.10 - 0.10
0.20 - 0.20
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
FDUM45KXE6F
Power Input Cool - Heat
Running Current Cool - Heat
A
0.46 - 0.46
0.46 - 0.46
0.91 - 0.91
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,006
£1,048
£1,112
£40
£40
£54
Indoor Unit
Spigot Kit
Filter
Retail Price
£72
£72
£72
£1,118
£1,160
£1,238
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | As standard units come with rectangular air
outlets 660 x 200 (22-56), 860 x 200 (71-90), 1280 x 235 (112-160), the optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible
ductwork | No return air filter as standard.
ampair.co.uk | 01707 378 670 | [email protected]
135
VRF
Standard Ducted
VRF Indoor
Standard Ducted
Indoor Unit
FDUM90KXE6F
FDUM112KXE6F
AMP-FDUM-3
AMP-FDUM-4
UM-FL2EF
UM-FL3EF
90
112
Spigot Kit
PERFORMANCE
Filter
REFRIGERANT &
PIPEWORK
Nominal Cooling
kW
9.0
11.2
Nominal Heating
kW
10.0
12.5
Height
mm
280
280
Width
mm
950
1370
Depth
mm
635
740
Weight
kg
34
54
dB(A)
25 - 29 - 33 - 38
30 - 36 - 38 - 44
Airflow Rate (lo-me-hi-phi)
l/s
167 - 250 - 317 - 400
317 - 417 - 467 - 600
Static Pressure
Pa
100 @ 400l/s
100 @ 600l/s
Gas Pipe Size
in
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
mm
VP20 Standard
VP20 Standard
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.20 - 0.20
0.29 - 0.29
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
Power Input Cool - Heat
Running Current Cool - Heat
A
0.91 - 0.91
1.32 - 1.32
Starting Current
A
Less than 3A
Less than 3A
£1,276
£1,568
£54
£67
Indoor Unit
Spigot Kit
Filter
Retail Price
£72
£72
£1,402
£1,707
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | As standard units come with rectangular air
outlets 660 x 200 (22-56), 860 x 200 (71-90), 1280 x 235 (112-160), the optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible
ductwork | No return air filter as standard.
@amp_aircon |
amp-air-conditioning
136
VRF Indoor
Indoor Unit
Spigot Kit
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Filter
Capacity Code
FDUM160kXE6F
AMP-FDUM-4
AMP-FDUM-4
UM-FL3EF
UM-FL3EF
140
160
Nominal Cooling
kW
14.0
16.0
Nominal Heating
kW
16.0
18.0
Height
mm
280
280
Width
mm
1370
1370
Depth
mm
740
740
Weight
kg
54
54
dB(A)
29 - 34 - 40 - 45
30 - 35 - 40 - 47
Airflow Rate (lo-me-hi-phi)
l/s
333 - 433 - 533 - 650
367 - 467 - 583 - 800
Static Pressure
Pa
100 @ 650l/s
100 @ 800l/s
Gas Pipe Size
in
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
mm
VP20 Standard
VP20 Standard
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.33 - 0.33
0.45 - 0.45
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
FDUM140KXE6F
Power Input Cool - Heat
Running Current Cool - Heat
A
1.50 - 1.50
2.05 - 2.05
Starting Current
A
Less than 3A
Less than 3A
£1,672
£1,699
£67
£67
Indoor Unit
Spigot Kit
Filter
Retail Price
£72
£72
£1,811
£1,838
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | As standard units come with rectangular air
outlets 660 x 200 (22-56), 860 x 200 (71-90), 1280 x 235 (112-160), the optional AMP spigot kits provide either 2, 3 or 4 of 200mm diameter air outlets for connection of flexible
ductwork | No return air filter as standard.
Optional RCH-E3 hard wired controller
ampair.co.uk | 01707 378 670 | [email protected]
137
VRF
Standard Ducted
VRF Indoor
Low Static Ducted
Indoor Unit
Spigot Kit
PERFORMANCE
Filter
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
FDUT28KXE6F-E
n/a
n/a
FDUT36KXE6F-E
n/a
UTFL1EF
UTFL1EF
UTFL1EF
22
28
36
Nominal Cooling
kW
2.2
2.8
3.6
Nominal Heating
kW
2.5
3.2
4.0
Height
mm
200
200
200
Width
mm
750
750
750
Depth
mm
500
500
500
Weight
kg
21
21
22
dB(A)
22 - 26 - 28
22 - 26 - 28
26 - 30 - 33
Airflow Rate (lo-me-hi)
l/s
83 - 100 - 125
83 - 100 - 125
92 - 117 - 142
Static Pressure (Standard = 10 Pa)
Pa
35 max
35 max
35 max
Gas Pipe Size
in
3/8"
3/8"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP25 25id 32od
VP25 25id 32od
VP25 25id 32od
Capacity Code
Sound Pressure Level (lo-me-hi)**
Drain Connection
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.07 - 0.07
0.07 - 0.07
0.07 - 0.07
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
FDUT22KXE6F-E
Power Input Cool - Heat
Running Current Cool - Heat
A
0.28 - 0.29
0.28 - 0.29
0.32 - 0.33
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£772
£807
£829
n/a
n/a
n/a
Indoor Unit
Spigot Kit
Filter
£52
£52
£52
Retail Price
£824
£859
£881
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | ** Sound pressure reading taken 1.5m
below unit, readings 1m in front and 1m below air outlet are higher | Units come with rectangular air outlets 660 x 99 (22-36), 860 x 99 (45-56), 1060 x 99 (71) | No return air
filter as standard.
@amp_aircon |
amp-air-conditioning
138
VRF Indoor
Low Static Ducted
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Filter
FDUT56KXE6F-E
n/a
n/a
FDUT71KXE6F-E
n/a
UTFL2EF
UTFL2EF
UTFL3EF
45
56
71
Nominal Cooling
kW
4.5
5.6
7.1
Nominal Heating
kW
5.0
6.3
8.0
Height
mm
200
200
200
Width
mm
950
950
1150
Depth
mm
500
500
565
Weight
kg
25
25
31
dB(A)
28 - 32 - 34
30 - 33 - 35
28 - 31 - 35
Airflow Rate (lo-me-hi)
l/s
117 - 150 - 192
120 - 150 - 208
158 - 217 - 267
Static Pressure (Standard = 10 Pa)
Pa
50 max
50 max
50 max
Gas Pipe Size
in
1/2"
1/2"
5/8"
Liquid Pipe Size
in
1/4"
1/4"
3/8"
mm
VP25 25id 32od
VP25 25id 32od
VP25 25id 32od
Capacity Code
Sound Pressure Level (lo-me-hi)**
Drain Connection
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.08 - 0.08
0.08 - 0.08
0.08 - 0.08
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
FDUT45KXE6F-E
Power Input Cool - Heat
Running Current Cool - Heat
A
0.36 - 0.34
0.38 - 0.35
0.42 - 0.46
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£864
£887
£892
n/a
n/a
n/a
Indoor Unit
Spigot Kit
Filter
£52
£52
£52
Retail Price
£916
£939
£944
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | ** Sound pressure reading taken 1.5m
below unit, readings 1m in front and 1m below air outlet are higher | Units come with rectangular air outlets 660 x 99 (22-36), 860 x 99 (45-56), 1060 x 99 (71) | No return air
filter as standard.
ampair.co.uk | 01707 378 670 | [email protected]
139
VRF
Indoor Unit
Spigot Kit
VRF Indoor
Compact Ducted
Indoor Unit
Spigot Kit
PERFORMANCE
Filter
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
FDUH28KXE6F
n/a
n/a
FDUH36KXE6F
n/a
UH-FL1E
UH-FL1E
UH-FL1E
22
28
36
Nominal Cooling
kW
2.2
2.8
3.6
Nominal Heating
kW
2.5
3.2
4.0
Height
mm
257
257
257
Width
mm
570
570
570
Depth
mm
530
530
530
Weight
kg
22
22
22
dB(A)
27 - 30 - 33 - 39
27 - 30 - 33 - 39
27 - 30 - 33 - 39
Airflow Rate (lo-me-hi-phi)
l/s
100 - 108 - 117 - 142
100 - 108 - 117 - 142
100 - 108 - 117 - 142
Static Pressure
Pa
30
30
30
Gas Pipe Size
in
3/8"
3/8"
1/2"
Capacity Code
Sound Pressure Level (lo-me-hi-phi)
Liquid Pipe Size
Drain Connection
in
1/4"
1/4"
1/4"
mm
VP20 (20id 26od)
VP20 (20id 26od)
VP20 (20id 26od)
No
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
FDUH22KXE6F
Power Input Cool - Heat
A
5
5
5
kW
0.07 - 0.07
0.07 - 0.07
0.07 - 0.07
Running Current Cool - Heat
A
0.32 - 0.32
0.32 - 0.32
0.32 - 0.32
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£710
£728
£889
n/a
n/a
n/a
Indoor Unit
Spigot Kit
Filter
£78
£78
£78
Retail Price
£788
£806
£967
Communication cable - 2 core non polar 1.5mm2 screened cable | As standard units come with rectangular air outlets | No return air filter as standard.
@amp_aircon |
amp-air-conditioning
140
VRF Indoor
Hi Static Ducted
FDU45KXE6F
FDU56KXE6F
Spigot Kit
n/a
n/a
n/a
Filter
n/a
n/a
n/a
45
56
71
Nominal Cooling
kW
4.5
5.6
7.1
Nominal Heating
kW
5.0
6.3
8.0
Height
mm
280
280
280
Width
mm
750
750
950
Depth
mm
635
635
635
Weight
kg
29
29
34
dB(A)
26 - 29 - 32 - 37
26 - 29 - 32 - 37
25 - 29 - 33 - 38
Airflow Rate (lo-me-hi-phi)
l/s
133 - 150 - 167 - 217
133 - 150 - 167 - 217
167 - 250 - 317 - 400
Static Pressure
Pa
200 @ 217l/s
200 @ 217l/s
200 @ 400l/s
Gas Pipe Size
in
1/2"
1/2"
5/8"
Liquid Pipe Size
in
1/4"
1/4"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Capacity Code
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.10 - 0.10
0.10 - 0.10
0.25 - 0.25
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
FDU71KXE6F
Power Input Cool - Heat
Running Current Cool - Heat
A
0.63 - 0.63
0.63 - 0.63
1.80 - 1.80
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,010
£1,070
£1,207
n/a
n/a
n/a
Indoor Unit
Spigot Kit
Filter
Retail Price
n/a
n/a
n/a
£1,010
£1,070
£1,207
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | Units come with rectangular air outlets, 680
x 170 (45-56), 880 x 170 (71-90), 1200 x 170 (112-160), 1450 x 250 (224-280) | No return air filter | Max 200 with optional U-FCRA Fan Control Kit - £162.00.
ampair.co.uk | 01707 378 670 | [email protected]
141
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
VRF Indoor
Hi Static Ducted
PERFORMANCE
Indoor Unit
FDU112KXE6F
n/a
n/a
n/a
Filter
n/a
n/a
n/a
90
112
140
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
Capacity Code
FDU140KXE6F
Nominal Cooling
kW
9.0
11.2
14.0
Nominal Heating
kW
10.0
12.5
16.0
Height
mm
280
280
280
Width
mm
950
1370
1370
Depth
mm
635
740
740
Weight
kg
34
54
54
dB(A)
25 - 29 - 33 - 38
30 - 36 - 38 - 44
29 - 34 - 40 - 45
Airflow Rate (lo-me-hi-phi)
l/s
167 - 250 - 317 - 400
317 - 417 - 467 - 600
333 - 433 - 533 - 650
Static Pressure
Pa
200 @ 400l/s
200 @ 600l/s
200 @ 650l/s
Gas Pipe Size
in
5/8"
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Yes (600mm)*
Yes (600mm)*
Yes (600mm)*
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.25 - 0.25
0.32 - 0.32
0.36 - 0.36
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
FDU90KXE6F
Spigot Kit
Power Input Cool - Heat
Running Current Cool - Heat
A
1.80 - 1.80
2.00 - 2.00
2.30 - 2.30
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,373
£1,684
£1,776
n/a
n/a
n/a
Indoor Unit
Spigot Kit
Filter
Retail Price
n/a
n/a
n/a
£1,373
£1,684
£1,776
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | Units come with rectangular air outlets, 680
x 170 (45-56), 880 x 170 (71-90), 1200 x 170 (112-160), 1450 x 250 (224-280) | No return air filter | Max 200 with optional U-FCRA Fan Control Kit - £162.00.
@amp_aircon |
amp-air-conditioning
142
VRF Indoor
Hi Static Ducted
FDU160kXE6F
FDU224KXE6F
Spigot Kit
n/a
n/a
n/a
Filter
n/a
n/a
n/a
160
224
280
Nominal Cooling
kW
16.0
22.4
28.0
Nominal Heating
kW
18.0
25.0
31.5
Height
mm
280
360
360
Width
mm
1370
1570
1570
Depth
mm
740
830
830
Weight
kg
54
92
92
dB(A)
30 - 35 - 40 - 47
51 (hi)
52 (hi)
Airflow Rate (lo-me-hi-phi)
l/s
367 - 467 - 583 - 800
850 (hi)
1133 (hi)
Static Pressure
Pa
200 @ 800l/s
100**
100**
Gas Pipe Size
in
5/8"
3/4"
7/8"
Liquid Pipe Size
in
3/8"
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
VP25 (25id 32od)
Capacity Code
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
FDU280kXE6F
Power Input Cool - Heat
V-Ph-Hz
Yes (600mm)*
No
No
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
6
6
kW
0.43 - 0.43
1.03 - 0.90
1.05 - 0.96
Running Current Cool - Heat
A
2.70 - 2.70
4.34 - 3.90
4.38 - 4.00
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,910
£2,630
£2,612
n/a
n/a
n/a
Indoor Unit
Spigot Kit
Filter
Retail Price
n/a
n/a
n/a
£1,910
£2,630
£2,612
Communication cable - 2 core non polar 1.5mm2 screened cable | * Max height of lift pump is 600mm from the bottom of the unit | Units come with rectangular air outlets, 680
x 170 (45-56), 880 x 170 (71-90), 1200 x 170 (112-160), 1450 x 250 (224-280) | No return air filter | Max 200 with optional U-FCRA Fan Control Kit - £162.00.
Extended warranties,
reward points &
marketing cashback.
See page 183
ampair.co.uk | 01707 378 670 | [email protected]
143
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
VRF Indoor
Wall Mounted
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
FDK28KXE6F
FDK36KXE6F
n/a
n/a
n/a
Capacity Code
22
28
36
2.2
2.8
3.6
Nominal Cooling
kW
Nominal Heating
kW
2.5
3.2
4.0
Height
mm
298
298
298
Width
mm
840
840
840
Depth
mm
259
259
259
Weight
kg
12
12
12
dB(A)
31 - 33 - 35 - 38
31 - 33 - 35 - 38
31 - 35 - 41 - 48
Airflow Rate (lo-me-hi-phi)
l/s
100 - 117 - 133 - 183
100 - 117 - 133 - 183
117 - 150 - 167 - 250
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
3/8"
3/8"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP16 14id 16od
VP16 14id 16od
VP16 14id 16od
No
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.05 - 0.04
0.05 - 0.04
0.05 - 0.04
Running Current Cool - Heat
A
0.23 - 0.23
0.23 - 0.23
0.23 - 0.23
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£628
£643
£660
n/a
n/a
n/a
£628
£643
£660
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
FDK22KXE6F
Grille/Spigot Kit
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable.
@amp_aircon |
amp-air-conditioning
144
VRF Indoor
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
FDK45KXE6F
FDK56KXE6F
FDK71KXE6F
Grille/Spigot Kit
n/a
n/a
n/a
Capacity Code
45
56
71
4.5
5.6
7.1
Nominal Cooling
kW
Nominal Heating
kW
5.0
6.3
8.0
Height
mm
298
298
318
Width
mm
840
840
1098
Depth
mm
259
259
248
Weight
kg
12.5
13
15.5
dB(A)
33 - 37 - 42 - 48
37 - 42 - 46 - 48
39 - 43 - 47 - 48
Airflow Rate (lo-me-hi-phi)
l/s
117 - 150 - 183 - 250
167 - 200 - 233 - 267
250 - 300 - 350 - 400
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
1/2"
1/2"
5/8"
Liquid Pipe Size
in
1/4"
1/4"
3/8"
mm
VP16 14id 16od
VP16 14id 16od
VP16 14id 16od
No
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.05 - 0.05
0.05 - 0.05
0.09 - 0.09
Running Current Cool - Heat
A
0.23 - 0.23
0.23 - 0.23
0.48 - 0.48
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£684
£763
£797
n/a
n/a
n/a
£684
£763
£797
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
POWER
Suggested Fuse Size
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable.
ampair.co.uk | 01707 378 670 | [email protected]
145
VRF
Wall Mounted
VRF Indoor
Ceiling Suspended
REFRIGERANT &
PIPEWORK
FDE36KXE6F
FDE45KXE6F
FDE56KXE6F
Grille/Spigot Kit
n/a
n/a
n/a
Capacity Code
36
45
56
3.6
4.5
5.6
Nominal Cooling
kW
Nominal Heating
kW
4.0
5.0
6.3
Height
mm
210
210
210
Width
mm
1070
1070
1070
Depth
mm
690
690
690
Weight
kg
28
28
28
dB(A)
36 - 38 - 39 - 46
36 - 38 - 39 - 46
36 - 38 - 39 - 46
Airflow Rate (lo-me-hi-phi)
l/s
117 - 150 - 167 - 183
117 - 150 - 167 - 183
117 - 150 - 167 - 183
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
1/2"
1/2"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
1/4"
mm
VP20 20id 26od
VP20 20id 26od
VP20 20id 26od
No
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.06 - 0.06
0.06 - 0.06
0.06 - 0.06
Running Current Cool - Heat
A
0.26 - 0.25
0.26 - 0.25
0.26 - 0.25
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,278
£1,324
£1,358
n/a
n/a
n/a
£1,278
£1,324
£1,358
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable.
@amp_aircon |
amp-air-conditioning
146
VRF Indoor
Ceiling Suspended
FDE71KXE6F
FDE112KXE6F
Grille/Spigot Kit
n/a
n/a
n/a
Capacity Code
71
112
140
Nominal Cooling
kW
7.1
11.2
14.0
Nominal Heating
kW
8.0
12.5
16.0
Height
mm
210
250
250
Width
mm
1320
1620
1620
Depth
mm
690
690
690
Weight
kg
37
49
49
dB(A)
37 - 39 - 41 - 50
39 - 41 - 44 - 46
43 - 44 - 46 - 50
Airflow Rate (lo-me-hi-phi)
l/s
200 - 233 - 267 - 300
350 - 383 - 433 - 467
383 - 433 - 483 - 533
Static Pressure
Pa
0
0
0
Gas Pipe Size
in
5/8"
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
3/8"
mm
VP20 20id 26od
VP20 20id 26od
VP20 20id 26od
No
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.11 - 0.10
0.16 - 0.15
0.18 - 0.17
Running Current Cool - Heat
A
0.48 - 0.44
0.67 - 0.63
0.78 - 0.72
Starting Current
A
Less than 3A
Less than 3A
Less than 3A
£1,449
£1,505
£1,753
n/a
n/a
n/a
£1,449
£1,505
£1,753
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
FDE140KXE6F
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
Communication cable - 2 core non polar 1.5mm2 screened cable.
ampair.co.uk | 01707 378 670 | [email protected]
147
VRF
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
VRF Indoor
Floor Standing Chassis
REFRIGERANT &
PIPEWORK
FDFU28KXE6F
FDFU45KXE6F
Grille/Spigot Kit
n/a
n/a
Capacity Code
28
45
2.8
4.5
Nominal Cooling
kW
Nominal Heating
kW
3.2
5.0
Height
mm
630
630
Width
mm
1077
1077
Depth
mm
225
225
Weight
kg
25
25
dB(A)
36 - 38 - 41
40 - 41 - 43
Airflow Rate (lo-me-hi-phi)
l/s
167 - 183 - 200
167 - 200 - 233
Static Pressure
Pa
0
0
Gas Pipe Size
in
3/8"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
mm
VP20 (20id 26od)
VP20 (20id 26od)
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.10 - 0.10
0.10 - 0.10
Running Current Cool - Heat
A
0.42 - 0.42
0.42 - 0.42
Starting Current
A
Less than 3A
Less than 3A
£1,244
£1,256
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
n/a
n/a
£1,244
£1,256
Communication cable - 2 core non polar 1.5mm2 screened cable.
@amp_aircon |
amp-air-conditioning
148
VRF Indoor
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
FDFU56KXE6F
FDFU71KXE6F
Grille/Spigot Kit
n/a
n/a
Capacity Code
56
71
5.6
7.1
Nominal Cooling
kW
Nominal Heating
kW
6.3
8.0
Height
mm
630
630
Width
mm
1077
1362
Depth
mm
225
225
Weight
kg
25
32
dB(A)
40 - 41 - 43
40 - 41 - 43
Airflow Rate (lo-me-hi-phi)
l/s
167 - 200 - 233
200 - 250 - 300
Static Pressure
Pa
0
0
Gas Pipe Size
in
1/2"
5/8"
Liquid Pipe Size
in
1/4"
3/8"
mm
VP20 (20id 26od)
VP20 (20id 26od)
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.10 - 0.10
0.10 - 0.10
Running Current Cool - Heat
A
0.42 - 0.42
0.42 - 0.42
Starting Current
A
Less than 3A
Less than 3A
£1,278
£1,312
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
POWER
Suggested Fuse Size
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
n/a
n/a
£1,278
£1,312
Communication cable - 2 core non polar 1.5mm2 screened cable.
ampair.co.uk | 01707 378 670 | [email protected]
149
VRF
Floor Standing Chassis
VRF Indoor
Floor Standing Cabinet
REFRIGERANT &
PIPEWORK
FDFW28KXE6F
FDFW45KXE6F
Grille/Spigot Kit
n/a
n/a
Capacity Code
28
45
2.8
4.5
Nominal Cooling
kW
Nominal Heating
kW
3.2
5.0
Height
mm
600
600
Width
mm
860
860
Depth
mm
238
238
Weight
kg
19
20
dB(A)
30 - 34 - 36
33 - 36 - 38
Airflow Rate (lo-me-hi-phi)
l/s
117 - 133 - 150
117 - 133 - 150
Static Pressure
Pa
0
0
Gas Pipe Size
in
3/8"
1/2"
Liquid Pipe Size
in
1/4"
1/4"
mm
VP16 (14id 16od)
VP16 (14id 16od)
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.02 - 0.02
0.02 - 0.20
Running Current Cool - Heat
A
0.10 - 0.10
0.10 - 0.10
Starting Current
A
Less than 3A
Less than 3A
£914
£934
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
VRF
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
n/a
n/a
£914
£934
Communication cable - 2 core non polar 1.5mm2 screened cable | FDFW units are bi-flow indoor units.
@amp_aircon |
amp-air-conditioning
150
VRF Indoor
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
REFRIGERANT &
PIPEWORK
FDFW56KXE6F
FDFL71KXE6F
Grille/Spigot Kit
n/a
n/a
Capacity Code
56
71
5.6
7.1
Nominal Cooling
kW
Nominal Heating
kW
6.3
8.0
Height
mm
600
630
Width
mm
860
1481
Depth
mm
238
225
Weight
kg
20
40
dB(A)
33 - 37 - 44
40 - 41 - 43
Airflow Rate (lo-me-hi-phi)
l/s
133 - 150 - 183
200 - 250 - 300
Static Pressure
Pa
0
0
Gas Pipe Size
in
1/2"
5/8"
Liquid Pipe Size
in
1/4"
3/8"
mm
VP16 (14id 16od)
VP20 (20id 26od)
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.03 - 0.03
0.10 - 0.10
Running Current Cool - Heat
A
0.15 - 0.15
0.42 - 0.42
Starting Current
A
Less than 3A
Less than 3A
£998
£1,419
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
POWER
Suggested Fuse Size
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
n/a
n/a
£998
£1,419
Communication cable - 2 core non polar 1.5mm2 screened cable | FDFW units are bi-flow indoor units.
ampair.co.uk | 01707 378 670 | [email protected]
151
VRF
Floor Standing Cabinet
VRF
“AMP are one of our top suppliers; they
are always very helpful and flexible with
excellent back up and support. Overall
they provide an excellent service.”
Liam Stay - Integra
Photo: Katie Smith, Internal Sales Administrator at AMP
@amp_aircon |
amp-air-conditioning
152
Air Handling & HRV
Air Handling & HRV
ampair.co.uk | 01707 378 670 | [email protected]
153
Air Handling & HRV
Outdoor Air Processing Unit
FDU500FKXE6F
FDU850FKXE6F
Grille/Spigot Kit
n/a
n/a
Capacity Code
90
140
9.0
14.0
Nominal Cooling
kW
Nominal Heating
kW
4.2
7.0
Height
mm
360
360
Width
mm
820
1200
Depth
mm
830
830
Weight
kg
48
62
dB(A)
38 + 5db(A) @ 200Pa
41 + 5db(A) @ 200Pa
Airflow Rate (lo-me-hi-phi)
l/s
142 @200Pa
233 @200Pa
Static Pressure
Pa
200
200
Gas Pipe Size
in
5/8"
5/8"
Liquid Pipe Size
in
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
3
5
kW
0.13 - 0.13
0.18 - 0.18
Running Current Cool - Heat
A
0.70 - 0.70
1.05 - 1.05
Starting Current
A
Less than 3A
Less than 3A
£2,857
£3,949
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
Air Handling & HRV
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
n/a
n/a
£2,857
£3,949
Only connectable to KXE6 heat pump outdoor units (8-24HP (224 - 680) | External static pressure is 100Pa with optional fan controller kit - U-FCRB | The total connection
capacity of the other standard air conditioning units and the outdoor air processing unit must be from 50% to 100% of the outdoor capacity | The outdoor air processing unit
must not exceed 30% of the capacity of the outdoor unit | Single outdoor air processing unit can be used alone, the connection capacity must be from 50% to 100% of the
outdoor unit, no more that 2 outdoor air processing units | Further conditions apply, see technical manual for full details.
@amp_aircon |
amp-air-conditioning
154
Air Handling & HRV
Outdoor Air Processing Unit
FDU1800FKXE6F
n/a
n/a
Capacity Code
224
280
Nominal Cooling
kW
22.4
28.0
Nominal Heating
kW
10.9
14.8
Height
mm
360
360
Width
mm
1570
1570
Depth
mm
830
830
Weight
kg
82
84
dB(A)
43 + 5db(A) @ 200Pa
46 + 5db(A) @ 200Pa
Airflow Rate (lo-me-hi-phi)
l/s
367 @200Pa
500 @200Pa
Static Pressure
Pa
200
200
Gas Pipe Size
in
3/4"
7/8"
Liquid Pipe Size
in
3/8"
3/8"
mm
VP25 (25id 32od)
VP25 (25id 32od)
No
No
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
A
5
5
kW
0.32 - 0.32
0.38 - 0.38
Running Current Cool - Heat
A
1.70 - 1.70
2.00 - 2.00
Starting Current
A
Less than 3A
Less than 3A
£4,567
£4,699
Sound Pressure Level (lo-me-hi-phi)
Drain Connection
Internal Lift Pump
Power Supply
Suggested Fuse Size
POWER
FDU1300FKXE6F
Grille/Spigot Kit
Power Input Cool - Heat
Indoor Unit
Grille/Spigot Kit
Retail Price
n/a
n/a
£4,567
£4,699
Only connectable to KXE6 heat pump outdoor units (8-24HP (224 - 680) | External static pressure is 100Pa with optional fan controller kit - U-FCRB | The total connection
capacity of the other standard air conditioning units and the outdoor air processing unit must be from 50% to 100% of the outdoor capacity | The outdoor air processing unit
must not exceed 30% of the capacity of the outdoor unit | Single outdoor air processing unit can be used alone, the connection capacity must be from 50% to 100% of the
outdoor unit, no more that 2 outdoor air processing units | Further conditions apply, see technical manual for full details.
ampair.co.uk | 01707 378 670 | [email protected]
155
Air Handling & HRV
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
Indoor Unit
Air Handling & HRV
PERFORMANCE
SAF-DX Fresh Air Assembly
Indoor Unit
SAF-DX250E6
SAF-DX350E6
Capacity Code
22
28
36
kW
2.0
2.8
3.6
Nominal Heating
kW
1.8
2.2
2.8
Height
mm
315
315
315
Width
mm
452
452
537
Depth
mm
422
422
422
Weight
kg
12.3
12.3
13.6
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
Nominal Cooling
Sound Pressure Level
dB(A)
n/a
n/a
n/a
Airflow Rate (Standard)
l/s
250 - 69
350 - 97
500 - 139
Internal Resistance
Pa
38
66
66
Gas Pipe Size
in
3/8"
3/8"
1/2"
Liquid Pipe Size
Drain Connection
1/4"
1/4"
1/4"
VP20 Standard
VP20 Standard
VP20 Standard
Optional
Optional
Optional
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
A
5
5
5
kW
0.72
0.72
0.72
Running Current
A
0.05
0.05
0.05
Starting Current
A
TBC
TBC
TBC
£2,784
£3,004
£3,222
Suggested Fuse Size
POWER
in
mm
Internal Lift Pump
Power Supply
Air Handling & HRV
SAF-DX500E6
Power Input
Retail Price
@amp_aircon |
amp-air-conditioning
156
Air Handling & HRV
Indoor Unit
SAF-DX800E6
Capacity Code
56
71
kW
5.6
6.3
Nominal Heating
kW
4.5
5.6
Height
mm
315
315
Width
mm
682
822
Depth
mm
422
422
Weight
kg
16.1
18.4
Nominal Cooling
Sound Pressure Level
dB(A)
n/a
n/a
Airflow Rate (Standard)
l/s
800 - 222
1000 - 278
Internal Resistance
Pa
66
66
Gas Pipe Size
in
1/2"
5/8"
Liquid Pipe Size
Drain Connection
in
1/4"
3/8"
mm
VP20 Standard
VP20 Standard
Optional
Optional
V-Ph-Hz
230 - 1 - 50
230 - 1 - 50
Internal Lift Pump
Power Supply
A
5
5
kW
0.72
0.72
Running Current
A
0.05
0.05
Starting Current
A
TBC
TBC
£3,464
£3,684
Suggested Fuse Size
POWER
SAF-DX1000E6
Power Input
Retail Price
ampair.co.uk | 01707 378 670 | [email protected]
157
Air Handling & HRV
REFRIGERANT &
PIPEWORK
SOUND &
AIRFLOW
PHYSICAL
PERFORMANCE
SAF-DX Fresh Air Assembly
Air Handling & HRV
SAF Heat Recovery Ventilation Units
SAF Unit
SAF150E6
SAF250E6
SAF350E6
SAF800E6
SAF1000E6
Remote Controller
Included
Included
Included
Included
Included
Included
Air Volume (High) m3/h - l/s
150 - 42
250 - 69
350 - 97
500 - 139
800 - 222
1000 - 278
Air Volume (Low)
120 - 33
190 - 53
240 - 67
440 - 122
630 - 175
700 - 194
270 x 970
x 467
270 x 882
x 599
317 x 1050
x 804
317 x 1090
x 904
388 x 1322
x 884
388 x 1322 x
1134
Dimension (h-w-d)
mm
Weight
kg
25
29
49
57
71
83
Mm
100
150
150
200
250
250
External Static Pressure - Extra High
Pa
80
105
140
120
140
105
External Static Pressure - High
Pa
70
95
60
60
110
80
External Static Pressure - Low
Pa
25
45
45
35
55
75
TBC
TBC
TBC
TBC
TBC
TBC
75 - 79
Duct Diameter
Filtration Efficiency Grade
Temperature Exchange Efficiency (H / L)
%
75 - 77
75 - 77
75 - 78
75 - 76
75 - 76
Sound Pressure Level - Extra High
dB(A)
29.0
31.5
33.0
37.5
37.5
38.5
Sound Pressure Level - High
dB(A)
29.0
30.5
31.0
35.5
37.0
37.5
Sound Pressure Level - Low
dB(A)
21.5
26.5
25.5
32.5
34.5
34.5
Power Supply (V-Ph-Hz)
Air Handling & HRV
SAF500E6
Power Input
Running Current
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
kW
0.11
0.12
0.19
0.23
0.38
0.43
A
0.5
0.5
0.8
0.9
1.6
1.8
Suggested Fuse Size
A
5
5
5
5
5
5
Enthalpy Exchange Eff. Cool - Heat Hi
%
63 - 70
63 - 70
66 - 69
62 - 67
65 - 71
65 - 71
Enthalpy Exchange Eff. Cool - Heat Low
%
Retail Price
66 - 73
65 - 72
71 - 73
64 - 69
68 - 74
70 - 76
£1,146
£1,278
£1,463
£1,657
£2,523
£2,804
Part Number
Description
MHI-SAFI
Fan interface for use with MHI indoor unit
£65
MHI-HEATER-KIT-150
Heater kit (fit at outside air inlet) for model 150
£805
MHI-HEATER-KIT-1
Heater kit (fit at outside air inlet) for model 250 & 350
£805
MHI-HEATER-KIT-2
Heater kit (fit at outside air inlet) for model 500
£830
MHI-HEATER-KIT-3
Heater kit (fit at outside air inlet) for model 800 & 1000
£850
@amp_aircon |
amp-air-conditioning
Retail Price
158
Air Handling & HRV
KX EEV Valve Kits for AHU Connection
EEV-KIT is a control kit for operating a locally provided
AHU and/or fan coil units with direct expansion (DX)
heat exchanger coils combined with the KX6 VRF
range.
Type
Capacity
kW
EEV6-71-E
EEV6-160-E
EEV6-280-E
22 - 71
90 - 160
224 - 280
2.2 - 7.1kW
9.0 - 16.0kW
22.4 - 28.0kW
Part Number
Description
EEVKIT6-E-M
Master control assembly
Retail Price
£1,636
EEVKIT6-E-C
Slave control assembly
£1,636
EEV6-71-E
Valve assembly 2.2 - 7.1kW (per DX coil)
£136
EEV6-160-E
Valve assembly 9.0 - 16.0kW (per DX coil)
£190
EEV-280-E
Valve assembly 22.4 - 28.0kW (per DX coil)
£220
Air Handling & HRV
Contact AMP for further information.
An example of 4 split DX heat exchangers.
The EEV-KIT is made up of the EEV control assembly and the EEV-valve assembly (coil
and strainers). Please note that the control assembly is not waterproof and must be
housed in a weather proof enclosure.
ampair.co.uk | 01707 378 670 | [email protected]
159
Air Handling & HRV
PAC Heat Exchanger Interface
Micro Inverter Single Phase
Outdoor Unit
FDC100VN
FDC125VN
FDC140VN
AHU Interface
FD-PAC
FD-PAC
FD-PAC
RC-E5
RC-E5
RC-E5
kW
10.0 (6.1 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
11.2 (5.6 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
m3/hr
min 1600
min. 2000
min. 2000
Air On Temperature Cooling
16° min - 32°C max
16° min - 32°C max
16° min - 32°C max
Air On Temperature Heating
10° min - 32°C max
10° min - 32°C max
10° min - 32°C max
Remote Controller
Cooling Capacity
Heating Capacity
Coil Air Flow
Max. Pipe Run
m
50
50
50
Pipe Sizes
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Yes
Yes
Yes
Replacement Technology
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
Outdoor Unit
Outdoor Power Supply (V-Ph-Hz)
£1,665
£1,965
£2,245
Interface
£1,150
£1,150
£1,150
Air Handling & HRV
Remote Controller inc. Time Clock
Retail Price
£63
£63
£63
£2,878
£3,178
£3,458
Micro Inverter Three Phase
Outdoor Unit
FDC100VS
FDC125VS
FDC140VS
FDC200VS
FDC250VS
AHU Interface
FD-PAC
FD-PAC
FD-PAC
FD-PAC
FD-PAC
RC-E5
RC-E5
RC-E5
RC-E5
RC-E5
Remote Controller
Cooling Capacity
kW
10.0 (6.1 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
20.0 (7.0 - 22.4)
25.0 (10.0 - 28.0)
Heating Capacity
kW
11.2 (5.6 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
22.4 (7.6 - 25.0)
28.0 (9.5 - 31.5)
min 1600
min. 2000
min. 2000
min. 3000
min. 4000
Coil Air Flow
m /hr
3
Air On Temperature Cooling
16° min - 32°C max 16° min - 32°C max 16° min - 32°C max 16° min - 32°C max 16° min - 32°C max
Air On Temperature Heating
10° min - 32°C max 10° min - 32°C max 10° min - 32°C max 10° min - 32°C max 10° min - 32°C max
Max. Pipe Run
m
50
50
50
70
70
Pipe Sizes
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
7/8" - 3/8"*
7/8" - 1/2"
Yes
Yes
Yes
Yes
Yes
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
400 - 3 - 50
Outdoor Unit
£1,744
£1,976
£2,277
£3,086
£3,489
Interface
£1,150
£1,150
£1,150
£1,150
£1,150
£63
£63
£63
£63
£63
£2,957
£3,189
£3,490
£4,299
£4,702
Replacement Technology
Outdoor Power Supply (V-Ph-Hz)
Remote Controller inc. Time Clock
Retail Price
* If pipe run is greater than 35m increase gas pipe to 1 1/8”,if pipe run is greater than 40m increase liquid pipe to 1/2”.
@amp_aircon |
amp-air-conditioning
160
Air Handling & HRV
PAC Heat Exchanger Interface
FDC71VNX
FDC100VNX
FDC125VNX
FDC140VNX
AHU Interface
FD-PAC
FD-PAC
FD-PAC
FD-PAC
RC-E5
RC-E5
RC-E5
RC-E5
kW
7.1 (3.2 - 8.0)
10.0 (6.1 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
kW
8.0 (3.6 - 9.0)
11.2 (5.6 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
m3/hr
min 1200
min 1600
min. 2000
min. 2000
Air On Temperature Cooling
16° min - 32°C max
16° min - 32°C max
16° min - 32°C max
16° min - 32°C max
Air On Temperature Heating
10° min - 32°C max
10° min - 32°C max
10° min - 32°C max
10° min - 32°C max
Remote Controller
Cooling Capacity
Heating Capacity
Coil Air Flow
Max. Pipe Run
m
50
100
100
100
Pipe Sizes
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Yes
Yes
Yes
Yes
230 - 1 - 50
Replacement Technology
Outdoor Power Supply (V-Ph-Hz)
230 - 1 - 50
230 - 1 - 50
230 - 1 - 50
Outdoor Unit
£1,546
£2,068
£2,424
£2,722
Interface
£1,150
£1,150
£1,150
£1,150
£63
£63
£63
£63
£2,759
£3,281
£3,673
£3,935
Remote Controller inc. Time Clock
Retail Price
Hyper Inverter Three Phase
Outdoor Unit
FDC100VSX
FDC125VSX
FDC140VSX
AHU Interface
FD-PAC
FD-PAC
FD-PAC
RC-E5
RC-E5
RC-E5
Remote Controller
Cooling Capacity
kW
10.0 (6.1 - 11.2)
12.5 (5.0 - 14.0)
14.0 (5.0 - 14.5)
Heating Capacity
kW
11.2 (5.6 - 12.5)
14.0 (4.0 - 16.0)
16.0 (4.0 - 16.5)
Coil Air Flow
m /hr
3
Air On Temperature Cooling
Air On Temperature Heating
min 1600
min. 2000
min. 2000
16° min - 32°C max
16° min - 32°C max
16° min - 32°C max
10° min - 32°C max
10° min - 32°C max
10° min - 32°C max
Max. Pipe Run
m
100
100
100
Pipe Sizes
in
5/8" - 3/8"
5/8" - 3/8"
5/8" - 3/8"
Yes
Yes
yes
Outdoor Power Supply (V-Ph-Hz)
400-3-50
400-3-50
400-3-50
Outdoor Unit
£2,240
£2,520
£2,848
Interface
£1,150
£1,150
£1,150
£63
£63
£63
£3,453
£3,733
£4,061
Replacement Technology
Remote Controller inc. Time Clock
Retail Price
Cooling mode “air on” temperature, minimum 12°CWB (18°CDB), maximum 24°CWB (32°CDB).
ampair.co.uk | 01707 378 670 | [email protected]
161
Air Handling & HRV
Hyper Inverter Single Phase
Outdoor Unit
Commercial air conditioning
that’s proud of its eco credentials
Following the popular KX6, the new and improved high performance KXZ series air
conditioning solution from Mitsubishi offers greater installation and design flexibility.
Plus, new lower power consumption not only makes the series highly energy efficient,
but, as the running costs are MUCH lower, the KXZ series is also kinder to the planet.
It’s commercial air conditioning as it should be.
99
Air Handling & HRV
For more information:
See
KXZ on page
Click
to mitsubishikxz.eu
KXZ Advert Office Grass 210x297 1-9-14.indd 1
@amp_aircon |
01/09/2014 12:53
amp-air-conditioning
162
3
Q-ton
Q-ton
ampair.co.uk | 01707 378 670 | [email protected]
163
Q-ton
The Q-ton Story
The high efficiency Q-ton is an air-to-water heat
pump using CO2 gas as a refrigerant, which can be
used in a variety of applications for the supply of
sanitary hot water. Q-ton has been featured as the
world’s first two-stage compressor (combining rotary
and scroll technology). It maintains high efficiency
and significantly improves performance at cold
outside air temperatures.
MHI’s design team launched this innovative unique
air source heat pump to allow maximum efficiency,
with minimal carbon footprint all controlled from
a comprehensive touch screen panel. Currently
with the increasing pressure of the use of low GWP
(Global Warming Potential) refrigerant, we believe
CO2 heat pump is the way forward to comply with
future regulations as well as market trends.
Rotary & Scroll Compressor
Q-ton meets a range of disparate demands including
the need for medium to large sanitary hot water
generation. This involves low electricity consumption
and a high level of environmental friendliness.
Litres/Day
5,000
Care Homes/Universities
10,000
Hotels/Spas
15,000
Apartement Blocks
Q-ton
3,000
Leisure Centres & Restaurants
For improved energy and carbon reduction
performances, it is necessary to manage the heat
source as well as the heat storage capacity. Q-ton
assures this is compatible with on-site hot water
requirements. For example a single remote panel
can control a unit with the heating capacity of 30kW
and up to 16 coupled units (a total of 480kW) for
better functionality. This enables the Q-ton to be
specified in a vast array of new build or retrofit
applications of all sizes.
apartment blocks, restaurants, fitness centres,
universities, hospitals, care homes, laundries and
food industries.
Systems can be set up to meet specific requirements
and a touch screen controller makes the system
simple to operate while the user-friendly graphic
display enables to monitor hot water production and
availability.
With an industry-beating coefficient of performance
of 4.3, it is the ideal system for serving hot water
requirements in commercial buildings like hotels,
@amp_aircon |
amp-air-conditioning
164
Q-ton
Why Q-ton?
Q-ton delivers outstanding performance and
environmental benefits to a varied number of
applications. Q-ton is exceptionally energy efficient
which results in big reductions in both power and
carbon emissions.
Q-ton uses safe and highly efficient CO2 as a
refrigerant which is environmentally friendly as it is a
natural gas and does not contain harmful ecological
impacts compared to other products using standard
refrigerants.
High Performance
High Efficiency
Environmentally
Responsible
Easy Operation
Long-term Reliability
Furthermore the Q-ton uses a constant hot water
supply from 60°C to 90°C and maintains the
full capacity at a very low ambient temperature.
Therefore there is no requirement for external
heating source and as a result this saves valuable
installation time and costs.
»» 60°C to 90°C water supply even with outside temperatures as low as -25°C
»» The ability to maintain 100% capacity down to -7°C
»» The industry’s highest coefficient of performance (4.3 in intermediate season)*
»» Massive reductions in both running costs and CO2 emissions
»» GWP (Global Warming Potential) = 1
»» ODP (Ozone Depletion Potential) = 0
»» Advanced, but simple to operate touch screen panel with LCD
»» User-friendly schedule setting and one-touch fill up operation
»» High quality robust technology
»» Long life expectancy
Q-ton
* Intermediate season conditions: Air on at 16°C, Water on at 17°C, Water off at 65°C.
Operation conditions: senior care home, 80 people, 8,000 L/day, 17°C conversion.
The above figures have not been issued from a real site and should be considered as an indication only.
Q-ton will contribute to reduce carbon emissions for any organisation associated with a Carbon Reduction
Commitment (CRC) scheme. Further savings are expected as the electricity becomes greener with the
decarbonisation of the grid.
ampair.co.uk | 01707 378 670 | [email protected]
165
Q-ton
How it works
Q-ton absorbs ‘free’ heat from outdoor air and
amplifies it to generate hot water swiftly and
efficiently. It generates hot water up to 90°C without
the requirement for an additional electric immersion
heater.
Hot water can be produced during off peak tariff
electricity which is then stored in a tank for daytime
use. Q-ton efficiently produces high-volume hot
water using just ambient air heat and a small
amount of electricity.
The Q-ton heat pump uses a coil of cold refrigerant
that absorbs ‘free’ heat from the outside air and a
2-stage compressor that puts the refrigerant under
high pressure in order to raise its temperature.
An on-board heat exchanger uses heat from the
refrigerant to generate the sanitary hot water.
Q-ton is usually used for direct boiler replacement as
it controls the water supply and storage temperature
as well as the output capacity.
»» Advanced touch screen remote controller panel
Easy Operation
»» Full dot liquid crystal display
»» Allows finely adjusted operation for energy savings
»» LCD panel with light tap operation introduced as the industry’s first
User Friendly
»» Large 3.8 inch full dot display
Q-ton
»» Back light function
Fill Up Operation
»» Regardless of the setting that has been applied, there is always the functionality to
manually refill the tank
Schedule Setting
»» Set a schedule such as a weekly operation pattern, day off or a peak-cut timer
The Q-ton Process
Q-ton seeks to provide energy, cost and carbon
savings. It is most efficient when cold water is used
to supply the heat pump. For that reason the cold
feed water is provided to the heat pump, via the
base of the storage stratified vessel.
Each storage vessel has five pockets into which
temperature sensors can be fitted to detect the
@amp_aircon |
amp-air-conditioning
volume (in % terms) of hot water held in the vessel
at any particular time. The programming of the
control system to hold specific volumes of hot water
at different times of day is based on a balance of
hot water demand and electricity tariffs, to ensure
security of supply at minimum cost.
166
Q-ton
How it works
Performance
Capacity
Efficiency
-25°C to 90°C
-7°C to 100
COP 4.3
90°C water supply even in extremely cold
regions with temps as low as -25°C
Keeping 100% capacity down to -7°C
The industry’s highest COP level
COP4.3 (intermediate season)
Q-ton Sizing Guide
Connect up to 16 units with 1 remote control
Q-ton heat pumps can be configured as stand-alone
units or run with up to 16 units in tandem, providing
anything from 3,000 to 100,000 litres of safe hot
water daily. Whether single or multiple units are
used, the Q-ton system is controlled from a single,
simple control panel that can be remotely installed
for ease of access and operation. Q-ton can be
installed as a replacement, addition or whole new
system, according to your needs.
Refrigerant such as carbon dioxide (R744) preserves
the ozone layer (ODP = 0) and has the lowest Global
Warming Potential (GWP = 1). Q-ton fits extremely
well with the latest building regulations reaching the
“excellent” mark from BREEAM.
Q-ton meets the stringent requirements of world’s foremost environmental
assessment method and rating system BREEAM.
ampair.co.uk | 01707 378 670 | [email protected]
167
Q-ton
Environmental Credentials
Q-ton
Specification & Accessories
Model Number
ESA30E-25
OPERATION
TO TOP UP*
Heating Capacity
Water Flow
Power Consumption
kW
30
L/min
8.97
kW
6.98
COP
OPERATION
TO TOP UP**
Heating Capacity
kW
OPERATING RANGE
PHYSICAL
SOUND &
AIRFLOW
REFRIGERANT &
PIPEWORK
See page 183
5.06
kW
10.73
Outdoor Air Temperature
°C
-25 to 43
Inlet Water Temperature
°C
5 - 63
Hot Water Outlet Temperature
°C
60 - 90
Water Pressure
kPa
500 or lower
Height
mm
1690
Width
mm
1350
Depth
mm
720 + 35
Weight
kg
375***
dB(A)
58.0
Air Volume
m3/min
260
Water Pump Head
m (kPa)
5m (49kPa) @ 17 L/min
Power Consumption
2.8
Operating sound
Feed Water Inlet
Rc 3/4 (Copper 20A)
Hot Water Outlet
Rc 3/4 (Copper 20A)
Drain Water Outlet
Rc 3/4 (Copper 20A)
kg
8.5
V-Ph-Hz
400 - 3 - 50
Suggested Fuse Size (per phase)
A
TBC
Maximum Current Per Phase
A
21
Starting Current Per Phase
A
R744 (CO2) Refrigerant Base Charge
Power Supply
POWER
30
L/min
Water Flow
COP
Q-ton
4.3
Extended warranties,
reward points &
marketing cashback.
Retail Price
5
POA
*Intermediate Season - Outdoor temperature 16°C DB / 12°C WB, water inlet temperature 17°C and hot
water outlet temperature 65°C | **Cold Season - Outdoor temperature -7°C DB / -8°C WB, water inlet
temperature 5°C and hot water outlet temperature 90°C (excluding heater for anti-freezing 345W) |
*** 385 kg during operation
Part Number
Description
Retail Price
MTH-Q1E
Wiring kit for unvented cylinder (20m length of wire)
POA
MTH-Q2E
Wiring kit for unvented cylinder (10m length of wire)
POA
MTH-Q3E
Hot water temperature sensor (1.25m length x 9)
POA
MTH-Q4E
3 way valve
POA
MTH-Q5E
Stop valve for hot water supply
POA
RC-Q1E
Remote controller
POA
RM-FGW
Remote monitoring system (one per installation required)
POA
RM-PWB
Remote monitoring PCB (one per Q-ton required)
POA
@amp_aircon |
amp-air-conditioning
168
Air to Water
Air to Water
ampair.co.uk | 01707 378 670 | [email protected]
169
Air to Water
Air to Water Heat Pump
Air to water heat pump is a revolutionary energy
recycling system which reduces environmental load.
and economical with integrated hot water heater,
immersion heater, circulating pump and climate
system within the indoor unit.
This first-rate energy saving system has been
developed by our exceptional technology. Our air to
water heat pump is a complete modern system for
heating, cooling and producing hot sanitary water for
houses, offering effective energy saving and reducing
carbon dioxide emissions. Our product is safe
The heat energy is retrieved from the outdoor air
through the outdoor unit, and is transferred to the
indoor unit by the medium of refrigerant circulated in
closed piping system.
»» Optimum annual operation costs thanks to
»» Water supply pressure at showers and faucets to
the inverter driven compressor. The speed of
the compressor is controlled according to the
demand, and the industries highest COP level of
4.08~4.44 in heating operation has been achieved.
second and third floors will not drop. By utilising
the direct incoming water supply and not using
water from a storage tank water pressure and
quality is maintained as well as the reduction in
risk of legionella bacteria generation.
»» The compact size (600x650mm footprint) has
been achieved by integrating the hot water tank
for sanitary water together with the water heat
exchanger in indoor unit. Electric wiring and piping
works are simpler due to integrated indoor unit
design.
»» Max temperature flow line is 65ºC with use of a
large-capacity auxiliary electric heater as standard
equipment for back-up so that the system will be
able to cope with irregular and excessive use of
hot water. (58ºC with only use of compressor)
»» Various sterilization temperature settings
according to the requirements of each country.
HT30
MT300
MT500
Volume
l
30
300
480
Volume - Hot Water Coil
l
-
14
21
Tapping Capacity - 12l/min
l
-
320
960
l
-
230
560
Tank Unit - (HMS140V only)
Air to Water
If a third party water storage tank is used, there will be a reduction of water pressure
at showers and faucets when they are used at the same time.
Tapping Capacity - 16l/min
Temperature Limiter
°C
90
90
90
Immersion Heater
kW
9kW 4 steps
9kW 4 steps
9kW 4 steps
Dimension (h-w-d)
mm
360 - 590 - 360
1880 - 600 - 600
1695 - 760 - 876
kg
24
110
130
1 230V 50Hz / 3
400V 50Hz
1 230V 50Hz / 3
400V 50Hz
1 230V 50Hz / 3
400V 50Hz
1"
1 1/8"
1"
1"
Weight (empty)
Power Supply (V-Ph-Hz)
Climate System Pipe
in
1"
Hot Water Pipe
in
-
Retail Price
@amp_aircon |
See System Price Opposite
amp-air-conditioning
170
Air to Water
Air to Water Heat Pump
Outdoor Unit
FDCW71VNX-A
FDCW100VNX-A
HWS-
HMA100V
HMA100V
HMS140V
Nominal Heating Capacity
kW
8.3 (2.0 - 8.3)
9.2 (3.5 - 10.5)
16.5 (4.2 - 17.2)
Heating Power Input
KW
2.03
2.07
3.93
4.09
4.28
4.20
Nominal Cooling Capacity
KW
7.1 (2.0 - 7.1)
8.0 (3.0 - 9.0)
-
Cooling Power Input
KW
2.65
2.85
-
2.68
2.81
-
Compatible Hydro Unit - See Table Below
COP
EER
FDCW140VNX-A
Tapping Capacity 12 litre/min
l
270
270
Tapping Capacity 16 litre/min
l
200
200
-
Operating Range Outdoor Temp - Heating
°C
-20°C to +43°C
-20°C to +43°C
-20°C to +43°C
Operating Range Outdoor Temp - Cooling
°C
15°C to 43°C
15°C to 43°C
15°C to 43°C
Operating Range Water Temp - Heating
°C
25°C to 58°C
25°C to 58°C
25°C to 58°C
Operating Range Water Temp - Cooling
°C
7°C to 25°C
7°C to 25°C
18°C to 25°C
mm
750 -- 880(+88) - 340
845 - 970 - 370 (+80)
1300 - 970 - 370 (+80)
Kg
60
81
105
1667
Unit Dimensions (h-w-d)
Unit Weight
L/s
833
1217
Db(A)
48
50
54
Pipe Limits (max run - height diff.)
m
30 - 7
30 - 7
30 - 7
Pre-charged for
m
15
15
15
Factory Charge
Kg
2.55
2.90
4.00
Pipe Size
In
3/8" & 5/8"
3/8" & 5/8"
3/8" & 5/8"
230 - 1 - 50
230 - 1 - 50
Airflow
Sound Pressure Level
230 - 1 - 50
Power Supply (V-Ph-Hz)
Indoor Unit
HMA100V
HMA140V
Volume - Total
Litres
270 +/- 5%
-
Volume - Hot Water Coil
Litres
14
-
Volume - Expansion Vessel
Litres
-
18
Immersion Heater
KW
9kW 4 steps (1 or 3)
-
Dimension (h-w-d)
mm
1760 - 600 - 650
1004 - 513 - 360
Weight (empty)
kg
140
60
Climate System Pipe
in
7/8"
1 1/8"
Hot Water Pipe
in
7/8"
-
Compression
Compression
Water Pipe Connections
Retail Price
£9,083
£9,342
£8,159*
Heating capacities are at water temp 35°C out / 30°C in, ambient 7°C DB, cooling capacities are at water temp 7°C out / 12°C in, ambient 35°C DB.
ampair.co.uk | 01707 378 670 | [email protected]
171
Air to Water
1 230V 50Hz / 3 400V 50Hz
Power Supply (V-Ph-Hz)
Air to Water
“AMP are our preferred supplier because
they are always honest, reliable,
responsive and helpful to deal with.
They make our work easy.”
Steven Maxwell - All Seasons Climate Control
Photo: Richard Morley, External Technical Support at AMP
@amp_aircon |
amp-air-conditioning
172
Controls
Controls
ampair.co.uk | 01707 378 670 | [email protected]
173
Controls
Wired, Wireless & Infrared Controllers
Wired Controllers
RC-EX1A
RC-E5
RCH-E3
Premium Remote
Controller
Standard Remote
Controller
Simplified Remote
Controller
Touch screen
controller for PAC &
KX complete with 7
day time clock and
duty share function.
2 wire controller for
PAC & KX complete
with 7 day time clock.
Simplified remote
controller ideal for
hotel applications.
£123
£63
£106
RCN-T-36W-E
RCN-TC-24W-ER
RCN-FW-E
Infrared Remote
Control Kit
Infrared Remote
Control Kit
Wireless Remote
Controller
Suitable for PAC & KX
FDT 4 way cassette
units.
Suitable for PAC &
KX FDTC compact
cassette units.
Suitable for KX FDFW
floor standing units.
£132
£132
£136
RCN-K-E
RC-N-K71-E
RCN-KIT3-E
Wireless Remote
Controller
Wireless Remote
Controller
Infrared Remote
Control Kit
Suitable for
KXFDK22-56 wall
mounted units.
Suitable for KXFDK71
wall mounted unit.
Suitable for several
PAC & KX models, see
below*.
£136
£136
£166
RCN-E1R
RCN-E-E
Infrared Remote
Control Kit
Infrared Remote
Control Kit
Suitable for PAC FDEN
ceiling suspended
units.
Suitable for KX FDE
ceiling suspended
units.
£72
£136
Controls
Wireless & Infrared Controllers
@amp_aircon |
amp-air-conditioning
* RCN-KIT3-E compatibility: PAC = FDUM & FDU
KX = FDTW, FDTS, FDTQ, FDUM, FDU, FDUT, FDUH,
FDFL, FDFU, SAF-DX & FDU-F.
Hard wired controllers can control up to 16 indoor
units in a single group | Hard wired controllers have a
built in return air sensor.
174
Controls
Wiring Adapters & Interfaces
SC-BIKN-E
SC-ADNA-E
PCZ006A043
RAC Adapter
Superlink Adapter
CNT Connector
Used to connected
wired controller and/
or CNT to SRK, SRF &
SRR indoor units.
For the connection of
RAC & PAC systems
to central control
network.
Provides remote
on/off control and
run, fault, heat and
compressor outputs
(see below).
£151
£106
£10
MHI-SAFI
SC-GIFN-E
SC-THB-E3
SAF Heat
Recovery Unit
Fan Interface
SAF Unit
Interface
Remote Return
Air Sensor
Used to start / stop
SAF heat recovery unit
in conjunction with
indoor unit.
Used to connect SAF
heat recovery units to
the superlink central
control network.
For sensing room
air condition remote
from the indoor unit
(8m lead).
£65
£451
£82
Controls
Wiring diagrams
for using the CNT
connector for
remote on/off and
fault indication. It
can also be used
for run, heating
and compressor
indication.
ampair.co.uk | 01707 378 670 | [email protected]
175
Controls
Centralised Remote Controllers
SC-SL1N-E
SC-SL2NA-E
Centralised
Controller
Centralised
Controller
On/off of up to 16
indoor units.
Full function
centralised controller
for up to 64 indoor
units, complete with
time clock.
£378
£814
SC-SL3NA-BE
Touch Screen
Centralised
Controller
Full function
centralised controller
for up to 64 indoor
units + electric usage
calculation.
Limited stocks
Controls
£2607
@amp_aircon |
amp-air-conditioning
176
Controls
SL4 Centralised Touch Screen Controller
Full colour touch screen central controller SCSL4-AE/BE, complete with a 9 inch interactive LCD
display. It offers control, monitoring, scheduling
and service / maintenance functions for up to 128
indoors units. Control and monitoring via a PC is also
possible through your browser by connecting to the
LAN port.
Touch screen controller & PC control, without energy monitoring, allows MHI KX & PAC/RAC* indoor units to be controlled and
monitored via a touch screen panel and / or a PC through your browser.
Item
SC-SL4-AE
Retail
Price
Description
Touch panel central controller - 128 indoor units max**
£2,685
Between 1 & 128
Indoor Units
Between 129 & 256
Indoor Units
Qty Req.
Total
Retail
Qty Req.
Total
Retail
1
£2,685
2
£5,370
Optional Items
SC-ADNA-E
Interface PCB required by each RAC / PAC split system connected to above controls system (RAC
system also require SC-BIKN-E)
£106
SC-BIKN-E
Interface for SRK, SRF & SRR units to allow connection of SC-ADNA-E & wired remote controller
£151
RC-E5
AMP recommend the use of an RC-E5 remote controller for each SC-ADNA-E interface to assist in
commissioning
£63
COMM2
Controls commissioning assistance service, 1 day per 64 indoor units recommended (net price)
£650
Touch screen controller & PC control, with energy monitoring, allows MHI KX & PAC/RAC* indoor units to be controlled and
monitored via a touch screen panel and / or a PC through your browser.
Item
SC-SL4-BE
Retail
Price
Description
Touch panel central controller - 128 indoor units
max** - with electric usage function
£3,608
Between 1 & 64
Indoor Units
Between 193 & 256
Indoor Units
Qty Req.
Total
Retail
Qty Req.
Total
Retail
1
£3,608
2
£7,216
SC-ADNA-E
Interface PCB required by each RAC / PAC split system connected to above controls system (RAC
system also require SC-BIKN-E)
£106
SC-BIKN-E
Interface for SRK, SRF & SRR units to allow connection of SC-ADNA-E & wired remote controller
£151
RC-E5
AMP recommend the use of an RC-E5 remote controller for each SC-ADNA-E interface to assist in
commissioning
£63
COMM2
Energy Panel
Controls commissioning assistance service, 1 day per 64 indoor units recommended (net price)
Pulse meter, housing and wiring for energy pulse meter, 1 required per refrigeration system
£650
POA
* Require SC-ADNA-E interface | For installations with more than 256 indoor units please contact AMP for pricing | **Indoor units connected to the same outdoor unit can not
be connected to 2 different controllers, as such this may reduce the maximum capacity of each controller.
ampair.co.uk | 01707 378 670 | [email protected]
177
Controls
Optional Items
Controls
WEB & LON Works Gateways
WEB Gateway - without energy monitoring - allows MHI KX & PAC/RAC* indoor units to be controlled and monitored via a PC +
energy monitor calculation.
Item
SC-WGWNB-A
Retail
Price
Description
PC Gateway - 128 indoor units max (64 per circuit)**
£4,505
Between 1 & 128
Indoor Units
Between 129 & 256
Indoor Units
Qty Req.
Total
Retail
Qty Req.
Total
Retail
1
£4,505
2
£9,010
Optional Items
SC-ADNA-E
Interface PCB required by each RAC / PAC split system connected to above controls system (RAC
system also require SC-BIKN-E)
£106
SC-BIKN-E
Interface for SRK, SRF & SRR units to allow connection of SC-ADNA-E & wired remote controller
£151
RC-E5
AMP recommend the use of an RC-E5 remote controller for each SC-ADNA-E interface to assist in
commissioning
£63
COMM2
Controls commissioning assistance service, 1 day per 64 indoor units recommended (net price)
£650
WEB Gateway - with energy monitoring - allows MHI KX & PAC/RAC* indoor units to be controlled and monitored via a PC +
energy monitor calculation.
Item
Retail
Price
Description
£4,905
Between 1 & 128
Indoor Units
Between 129 & 256
Indoor Units
Qty Req.
Total
Retail
Qty Req.
Total
Retail
1
£4,905
2
£9,810
SC-WGWNB-B
PC Gateway - 128 indoor units max (64 per circuit)**
SC-ADNA-E
Interface PCB required by each RAC / PAC split system connected to above controls system (RAC
system also require SC-BIKN-E)
£106
SC-BIKN-E
Interface for SRK, SRF & SRR units to allow connection of SC-ADNA-E & wired remote controller
£151
RC-E5
AMP recommend the use of an RC-E5 remote controller for each SC-ADNA-E interface to assist in
commissioning
£63
COMM2
Controls commissioning assistance service, 1 day per 64 indoor units recommended (net price)
£650
Energy Panel
Pulse meter, housing and wiring for energy pulse meter, 1 required per refrigeration system
POA
Optional Items
LON Gateway - without energy monitoring - allows MHI KX & PAC/RAC* indoor units to be controlled and monitored via
LONworks protocol.
Controls
Item
SC-LGWNA-A
Retail
Price
Description
LON Gateway - 96 indoor units max (48 per circuit)**
£5,695
Between 1 & 128
Indoor Units
Between 129 & 256
Indoor Units
Qty Req.
Total
Retail
Qty Req.
Total
Retail
1
£5,695
2
£11,390
Optional Items
SC-ADNA-E
Interface PCB required by each RAC / PAC split system connected to above controls system (RAC
system also require SC-BIKN-E)
£106
SC-BIKN-E
Interface for SRK, SRF & SRR units to allow connection of SC-ADNA-E & wired remote controller
£151
RC-E5
AMP recommend the use of an RC-E5 remote controller for each SC-ADNA-E interface to assist in
commissioning
£63
COMM2
Controls commissioning assistance service, 1 day per 64 indoor units recommended (net price)
£650
* require SC-ADNA-E interface | For installations with more than 256 / 192 indoor units please contact AMP for pricing | **Indoor units connected to the same outdoor unit can
not be connected to 2 different circuits, as such this may reduce the maximum capacity of each controller.
@amp_aircon |
amp-air-conditioning
178
Controls
BACnet Gateway
BACnet Gateway - without energy monitoring - allows MHI KX & PAC/RAC* indoor units to be controlled and monitored via
BACnet protocol.
Item
SC-BGWNA-A
Retail
Price
Description
BACnet Gateway - 128 indoor units max (64 per circuit)**
SC-BGWNA256
BACnet Gateway - 256 indoor units max (128 per circuit)**
-A
Between 1 & 128
Indoor Units
Between 129 & 256
Indoor Units
Qty Req.
Total
Retail
Qty Req.
Total
Retail
£5,695
1
£5,695
n/a
n/a
TBC
n/a
n/a
1
TBC
Optional Items
SC-ADNA-E
Interface PCB required by each RAC / PAC split system connected to above controls system (RAC
system also require SC-BIKN-E)
£106
SC-BIKN-E
Interface for SRK, SRF & SRR units to allow connection of SC-ADNA-E & wired remote controller
£151
RC-E5
AMP recommend the use of an RC-E5 remote controller for each SC-ADNA-E interface to assist in
commissioning
£63
COMM2
Controls commissioning assistance service, 1 day per 64 indoor units recommended (net price)
£650
BACnet Gateway - with energy monitoring - allows MHI KX & PAC/RAC* indoor units to be controlled and monitored via
BACnet protocol
Item
Retail
Price
Description
Between 1 & 128
Indoor Units
Between 129 & 256
Indoor Units
Qty Req.
Total
Retail
Qty Req.
Total
Retail
SC-BGWNA-B
BACnet Gateway - 128 indoor units max (64 per circuit)**
£6,675
1
£6,675
n/a
n/a
SCBGWNA256-B
BACnet Gateway - 256 indoor units max (128 per circuit)**
TBC
n/a
n/a
1
TBC
SC-ADNA-E
Interface PCB required by each RAC / PAC split system connected to above controls system (RAC
system also require SC-BIKN-E)
£106
SC-BIKN-E
Interface for SRK, SRF & SRR units to allow connection of SC-ADNA-E & wired remote controller
£151
RC-E5
AMP recommend the use of an RC-E5 remote controller for each SC-ADNA-E interface to assist in
commissioning
£63
COMM2
Controls commissioning assistance service, 1 day per 64 indoor units recommended (net price)
£650
Energy Panel
Pulse meter, housing and wiring for energy pulse meter, 1 required per refrigeration system
POA
* Require SC-ADNA-E interface | For installations with more than 256 / 192 indoor units please contact AMP for pricing | **Indoor units connected to the same outdoor unit
can not be connected to 2 different circuits, as such this may reduce the maximum capacity of each controller.
From L to R: SC-WGWN-B, SC-LGWN-A, SC-BGWN-B
ampair.co.uk | 01707 378 670 | [email protected]
179
Controls
Optional Items
Controls
Controls
BMS Interfaces
MH-RC-KNX-1i
MH-AC-KNX-48
MH-AC-KNX-128
KNX Interface For
Pac Units
KNX Gateway
KNX Gateway
For control and
monitoring of single
indoor unit via KNX
protocol.
For control/
monitoring of up to
48 indoor units on
superlink network via
KNX protocol.
For control/
monitoring of up to
128 indoor units on
superlink network via
KNX protocol..
£295
£3,915
£5,365
MH-AC-MBS-128i
MH-RC-MBS-1
MH-AC-MBS-48
MODBUS
Gateway
MODBUS
Interface For
Pac Units
MODBUS
Gateway
For control/
monitoring of up to
128 indoor units on
superlink network via
MODBUS protocol.
For control and
monitoring of single
indoor unit via
MODBUS protocol.
For control/
monitoring of up to
48 indoor units on
superlink network via
MODBUS protocol.
£5,365
£295
£3,915
MH-RC-ENO-1
MH-RC-WIFI-1
IS-IR-WIFI-1
Enocean
Interface
INTESIS Home
Interface
Infrared WiFi
Adapter
MHI to Enocean
wireless protocol
interface (connects
directly to X/Y
terminals).
Suitable for PAC Units.
*See compatibility list.
*See compatibility list
for unit suitability.
£295
£295
£195
For the MH-AC-KNX-48 & 128 and the MH-AC-MBS-48
& 128 the following list of parameters can be controlled/
monitored on the indoor units.
»» Communication status (read only)
»» On/off
»» Operation mode
»» Setpoint
»» Fan speed
»» Remote controller lock / unlock
»» Louvre control
»» Room temp (read only)
»» Error code (read only)
»» Filter sign status (read only)
»» Comp status (read only) - Not MH-AC-MBS-1 or KNX-1
»» Thermo on/off (read only) - Not MH-AC-MBS-1 or KNX-1
@amp_aircon |
amp-air-conditioning
MH-RC-MBS-1
»» Total control and monitoring, including on/off, mode, set
point, fan speed, vane, error output and fault code, return
air sensor output & filter sign
»» Can be integrated with window contact etc.
MH-RC-KNX-1
»» Aircon unit can be controlled simultaneously by the wired
RC of the aircon unit and by KNX
»» Total control/monitoring of the aircon unit from KNX,
including monitoring the aircon units state of internal
variables, running hours counter, and error indication
and error code
* For compatibility list visit intesishome.com/compatibility
180
Controls
Brackets, Trays, Cages & Other Accessories
CBR2-M
CBR2-L
CBR1-XL
Small Outdoor
Unit Bracket
Medium Outdoor
Unit Bracket
Large Outdoor
Unit Bracket
Extra Large
Outdoor
Unit Bracket
Max load - 60KG
Max load - 90KG
Crossbar - 900mm
Upright - 500mm
Support arm - 500mm
Max load - 140KG
Crossbar - 1100mm
Upright - 550mm
Support arm - 540mm
Max load - 250KG
Crossbar - n/a
Upright - 550mm
Support arm - 700mm
£23
£32
£36
£55
CCTM-800
CCTM-1100
CCTM-1400
CG-BPS
CG-BPM
Small Heavy Duty
Metal Drain Tray
Large Heavy Duty
Metal Drain Tray
Large Heavy Duty
Metal Drain Tray
Base Panel For High
Level Cage
Installation
Base Panel For High
Level Cage
Installation
L800 X W400mm
L1100 X W400mm
L1400 X W400mm
For CG-S
For CG-M, CG-L and
CG-XL
£53
£58
£64
£41
£45
CG-S
CG-M
CG-L
CG-XL
Small
Condenser Cage
Medium
Condenser Cage
Large
Condenser Cage
Extra Large
Condenser Cage
External dimensions:
H750 X W1050 X
D460mm
Internal dimensions:
H720 X W1020 X
D450mm
Weight: 18kg
External dimensions:
H1150 X W1150 X
D650mm
Internal dimensions:
H1120 X W1120 X
D640mm
Weight: 30kg
External dimensions:
H1450 X W1150 X
D650mm
Internal dimensions:
H1420 X W1120 X
D640mm
Weight: 33kg
External dimensions:
H1800 X W1150 X
D650mm
Internal dimensions:
H1770 X W1120 X
D640mm
Weight: 44kg
£189
£272
£328
£468
CMB-450
CMB-1000
MBEC
450mm Outdoor
Unit Mounting
Block
1000mm Outdoor
Unit Mounting
Block
End Caps
Price Per Unit
Price Per Unit
Price Per Unit
£4
£9
£2
Controls
CBR2-S
Net Prices.
ampair.co.uk | 01707 378 670 | [email protected]
181
“Another successful year
Controls
with the help of AMP.
Great products, great support
& a Diamond partnership as well!”
Chris Diffey - UMC
Photo: Steve O’Brien, AMP Warehouse Operative
@amp_aircon |
amp-air-conditioning
182
ampair.co.uk | 01707 378 670 | [email protected]
183
AMP Diamonds
AMP Diamonds
AMP Diamonds
Rewards & Extended Warranties
Buy MHI products from AMP.
Build points.
Earn rewards.
AMP Diamonds
Created in conjunction with Mitsubishi Heavy
Industries, this exciting reward programme will
allow your company to build points on all MHI air
conditioning systems and turn them into vouchers
for well known high street brands. Additionally, you’ll
enjoy upgraded business benefits such as enhanced
product warranties and even a contribution to your
own marketing costs.*
When you sign up for AMP Diamonds, your extended
warranty will apply straight away. Once you’ve
surpassed the initial £10,000 joining threshold, your
company will also be eligible for reward points which
can be exchanged for gift vouchers at various bigbrand retailers.
If you surpass the £100,000 in annual spend, your
warranty will increase to 6 years and you’ll be eligible
for marketing cashback.
Benefit/requirement
Diamond Partner
Diamond Select Partner
Start earning points at
£10,000
£100,000
Training requirement
1 delegate per year
3 delegates per year
5 years parts & labour allowance
6 years parts & labour allowance
Enhanced warranty
Points allowance
1 point per £50 spend
Marketing cashback
No
Yes
AMP Diamonds
All members are required to have a valid F-Gas Company Registration. Contact AMP for more information.
Sign up now at ampdiamonds.co.uk
Terms & Conditions Apply. * Marketing cashback applies to Diamond Select Partners only.
@amp_aircon |
amp-air-conditioning
184
AMP Diamonds
How to Sign-up
1. Sign Up
2. Welcome Pack
3. Enhanced Warranty
Sign up at ampdiamonds.co.uk
with your company details and
F-Gas Registration Number.
Receive your exclusive AMP
Diamonds welcome gift pack &
membership certificate.
Benefit from an enhanced 5 or
6 year warranty on Mitsubishi
Heavy Industries products.
4. Start Earning Points
5. Redeem Points
6. Stay up to Date
Surpass £10,000 in eligible
orders after signing up and
start earning reward points.
Reach £50’s worth of points
and redeem your reward
vouchers or keep collecting.
Receive monthly emails
showing your points balance
and special offers.
Sign up now at ampdiamonds.co.uk
Terms & Conditions Apply. | Voucher retailers are subject to change without notice.
ampair.co.uk | 01707 378 670 | [email protected]
185
AMP Diamonds
Redeem your reward vouchers at a variety of well known on line and high street brands.
AMP Diamonds
FAQs
How many points will I receive and how much are
they worth?
You will receive 1 point for every £50 you spend on
qualifying MHI products after the initial threshold
of £10,000. 100 points equates to £50 in vouchers.
Vouchers will only be provided in denominations of
£50.
How many points do I need before I can claim a
voucher?
Your company will need to build a minimum of 100
points before you can claim your first voucher.
At which retailers can I redeem my vouchers?
Vouchers can be redeemed at John Lewis, Red Letter
Days, Amazon, Hotel Voucher Shop or M&S. You will
be asked to choose your retailer(s) when you claim
your voucher(s).
Do I have to spend a certain amount before I can
start earning points?
Points are applied to your company’s qualifying
invoices once you have spent over £10,000.
Which products qualify for points?
All Mitsubishi Heavy Industries units and accessories
products will qualify for the point’s scheme.
How do I become a Diamond Select Partner?
Once your company/branch spends over £100,000
and has reached the training requirement, you will
automatically become a Diamond Select Partner.
When will I get my welcome pack and certificate?
Your welcome pack and certificate will be dispatched
as soon as your sign-up details have been verified.
AMP Diamonds
Do I have to redeem my points within a certain
time scale?
Points must be used within 12 months of earning
them otherwise they will expire. i.e. points earned
in May 2016 will expire in May 2017. We will email
you once a month with updates and warnings if your
points are due to expire imminently.
Do the reward vouchers have an expiry date?
All vouchers have expiration dates, the length of
which varies by retailer. Please check the details on
your vouchers as once they have been claimed from
amp they cannot be replaced/reissued.
@amp_aircon |
amp-air-conditioning
How do I know what my points balance is?
You may contact amp for an update on your points a
balance however we will email you once a month with
an update.
How do I claim my vouchers?
Contact AMP and we will provide you with an up
to date points balance and what this equates to in
vouchers. You may then claim your vouchers on line
at ampdiamonds.co.uk or by emailing
[email protected]
Do I need to participate in any training to take
part in AMP Diamonds?
Yes. For Diamond Partner members, 1 member of
staff must attend/have attended a Mitsubishi Heavy
Industries training course, run by amp, each year.
Diamond Select Partners must allocate 3 members of
staff per year for this course.
What does the enhanced warranty include?
Standard MHI warranty terms are 3 years parts
and labour allowance. On becoming a Diamond
Partner this will increase to 5 years parts and labour
allowance. This will increase further to 6 years parts
and labour allowance for Diamond Select Partners.
How do I claim my marketing cashback and to
what does this apply?
Authorisation from amp will be required before
proceeding with any supported marketing activity.
On completion AMP will require copies of invoices to
support the claim.
Why do I need to provide my F-Gas Company
Certificate Number?
We are now required to hold your company’s F-Gas
Company Certificate Number on file. Without this we
are unable to sell you any air conditioning products.
This is simply a way for us to ensure we have your
correct information on file. We cannot accept your
application for membership without this information.
Can multiple people apply from my company/
branch?
We can only accept one application per company.
For companies with multiple branches, in different
locations, we will choose on a case-by-case basis
whether separate branches can sign up.
186
ampair.co.uk | 01707 378 670 | [email protected]
187
Reference/Faults
Reference/Faults
Reference
PAC Fault Codes
Remote
Controller
Error
Code
Red
LED
No
indication
Stays Off
Wait
E1
Indoor Control
PCB
Outdoor
PCB
Red
LED
Green
LED
Red
LED
Stays Off
Keeps
Flashing
-
Stays Off
Stays Off
-
3 Time
Flash
Keeps
Flashing
-
Stays Off
Keeps
Flashing
-
Stays Off
Keeps
Flashing
-
Location of Trouble
-
E5
E6
Keeps
Flashing
-
2 Time
Flash
Keeps
Flashing
-
2 Time
Flash
Keeps
Flashing
-
1 Time
Flash
Keeps
Flashing
-
Power OFF, broken wire/blown fuse, broken transformer wire
Remote control wires
Poor connection, breakage of remote control wire * For wire
breaking at power ON, the LED is OFF.
Remote control
Defective remote control PCB
Indoor-outdoor units connection
Poor connection, breakage of indoor-outdoor units
connection wire
Remote control
Improper setting of master and slave by remote control
Remote control wires (Noise)
Indoor-outdoor units connection
Keeps
Flashing
1 Time
Flash
Keeps
Flashing
1 Time
Flash
Keeps
Flashing
-
-
Occurrence of defective outdoor sub PCB on the way of
power supply (defective communication circuit)
Outdoor sub PCB
Defective outdoor sub PCB on the way of power supply
Fuse
Blown fuse
Indoor heat exchanger
temperature thermistor
Indoor return air temperature
thermistor
Indoor control PCB
Indoor heat exchanger
temperature thermistor
Reference/Faults
Drain trouble
1 Time
Flash
E10
Stays Off
E11
Keeps
Flashing
Keeps
Flashing
Keeps
Flashing
Keeps
Flashing
-
-
E14
3 Time
Flash
Keeps
Flashing
-
E16
1 (2) Time
Flash
Keeps
Flashing
-
@amp_aircon |
Defective remote control or indoor control PCB (defective
communication circuit)?
Poor connection of wire between indoor-outdoor units during
operation (disconnection, loose connection)
Anomalous communication between indoor-outdoor units
by noise, etc.
Outdoor sub PCB
Indoor control PCB
E9
Intrusion of noise in remote control wire
CPU-runaway on outdoor sub PCB
Installation or operating condition
E8
Poor connection of remote control signal wire (White)
(Noise)
Indoor control PCB
E7
Normal operation
Indoor unit power supply
Remote control indoor control
PCB
2 Time
Flash
Description of Trouble
Defective indoor heat exchanger temperature
thermistor(defective element, broken wire, short circuit)
Poor contact of temperature thermistor connector
Defective indoor control PCB (Defective temperature
thermistor input circuit)?
Defective indoor return air temperature thermistor • Poor
contact of temperature thermistor connector
Defective indoor control PCB (Defective temperature
thermistor input circuit)?
Heating over-load (Anomalously high indoor heat exchanger
temperature)
Defective indoor heat exchanger temperature thermistor
(short-circuit)
Defective indoor control PCB (Defective temperature
thermistor input circuit)?
Defective drain pump (DM), broken drain pump wire,
disconnected connector
Float switch
Anomalous float switch operation (malfunction)
Indoor control PCB
Defective indoor control PCB (float switch input circuit) or
(Defective DM drive output circuit)?
Option
Defective optional parts (At optional anomalous input setting)
Number of connected indoor units
When multi-unit control by remote control is performed, the
number of units is over
Address setting error
Address setting error of indoor units
Indoor unit No. setting
No master is assigned to slaves.
Remote control wires
Anomalous remote control wire connection. broken wire
between master and slave units
Fan motor
Defective fan motor
Indoor power PCB
Defective indoor power PCB
amp-air-conditioning
188
Reference
PAC Fault Codes
Remote
Controller
Error
Code
Red
LED
Indoor Control
PCB
Red
LED
Green
LED
1 Time
Flash
1 Time
Flash
Keeps
Flashing
Keeps
Flashing
E20
1 (2) Time
Flash
Keeps
Flashing
Keeps
Flashing
Keeps
Flashing
E18
E19
E21
1 Time
Flash
E28
Stays Off
E35
Stays Off
E36
Stays Off
Keeps
Flashing
Keeps
Flashing
Outdoor
PCB
Location of trouble
Description of trouble
-
Address setting error
Address setting error of master and slave indoor units
-
Indoor control PCB
Improper operation mode setting
-
Fan motor
Defective by rotation speed of fan motor
Indoor power PCB
Defective indoor power PCB
Panel switch detection
Defective panel switch operation (FDT only)
Remote control temperature
thermistor
Broken wire of remote control temperature thermistor
Red
LED
-
2 Times
Flash
5 Times
Flash
Installation, operation status
Higher outdoor heat exchanger temperature
Outdoor heat exchanger
temperature sensor
Defective outdoor heat exchanger temperature sensor
Outdoor main PCB
Defective outdoor main PCB (Defective temperature sensor
input circuit)?
Installation, operation status
Higher discharge temperature
Discharge pipe temperature
sensor
Defective discharge pipe temperature sensor
Outdoor main PCB
E37
Stays Off
Keeps
Flashing
8 Times
Flash
E38
Stays Off
Keeps
Flashing
8 Times
Flash
E39
Stays Off
Keeps
Flashing
8 Times
Flash
E40
Stays Off
Keeps
Flashing
4 Times
Flash
E42
Stays Off
Keeps
Flashing
1 Time
Flash
Keeps
Flashing
E47
Stays Off
Keeps
Flashing
1 Time
Flash
2 Times
Flash
E48
Stays Off
Keeps
Flashing
On
E51
Stays Off
Keeps
Flashing
1 Time
Flash
E57
Stays Off
Keeps
Flashing
2 Times
Flash
E58
Stays Off
Keeps
Flashing
3 Times
Flash
Outdoor heat exchanger
temperature sensor
Outdoor main PCB
Outdoor air temperature sensor
Outdoor main PCB
Discharge pipe temperature
sensor
Outdoor main PCB
Defective outdoor main PCB (Defective temperature sensor
input circuit)?
Defective outdoor heat exchanger temperature sensor,
broken wire or poor connector connection
Defective outdoor main PCB (Defective temperature sensor
input circuit)?
Defective outdoor air temperature sensor, broken wire or
poor connector connection
Defective outdoor main PCB (Defective temperature sensor
input circuit)?
Defective discharge pipe temperature sensor, broken wire or
poor connector
Defective outdoor main PCB (Defective temperature sensor
input circuit)?
Installation, operation status
Service valve (gas side) closing operation
Outdoor main PCB, compressor
Current cut (Anomalous compressor over-current)
Installation, operation status
Service valve closing operation
Outdoor main PCB
Over voltage
Defective active filter
Fan motor
Defective fan motor
Outdoor main PCB
Defective outdoor main PCB
Power transistor error (outdoor
main PCB)
Power transistor error
Operation status
Shortage in refrigerant quantity
Installation status
Service valve closing operation
Overload operation
Overcharge
Current safe stop
Compressor locking
Stays Off
E60
Stays Off
WAIT
Stays Off
Keeps
Flashing
2 Times
Flash
Keeps
Flashing
Keeps
Flashing
7 Times
Flash
6 Times
Flash
Compressor, outdoor main PCB
Anomalous compressor startup
Voltage drop
Compressor
Anomalous compressor rotor lock
Indoor-outdoor connection wire
Poor connection, breakage of indoor-outdoor units
connection wire
ampair.co.uk | 01707 378 670 | [email protected]
189
Reference/Faults
E59
Reference
KX Fault Codes
Remote
Controller
Error Code
7-Segment
Display
E1
E2
Fault Details
Error Type
–
Remote controller communication error
Communication error
–
Duplicated indoor unit address
Address setting error
E3
–
Outdoor unit signal line error
Address pairing setting error
E5
–
Communication error during operation
Communication error
E6
–
Indoor heat exchanger temperature thermistor anomaly (Thi-R)
Thermistor wire breakage
E7
–
Indoor return air temperature thermistor anomaly (Thi-A)
Thermistor wire breakage
E9
–
Drain trouble
System error
E10
–
Excessive number of indoor units (more than 17 units) by controlling one remote
controller
Communication error
E11
–
Address setting error of indoor units
Address setting error
E12
–
Address setting error by mixed setting method
Address setting error
–
Indoor fan motor anomaly (FDT series)
DC fan motor error
–
Indoor fan motor anomaly (FDK series)
DC fan motor error
E18
–
Address setting error of master and slave indoor units
Address setting error
E19
–
Indoor unit operation check drain motor check mode anomaly
Setting error
E28
–
Remote controller temperature thermistor anomaly (ThC)
Thermistor wire breakage
E30
E30
Unmatch connection of indoor and outdoor unit
System error
E31
E31
Duplicated outdoor unit address No.
Address setting error
E32
E32
Open L3 Phase on power supply at primary side
Site setting error
Discharge pipe temperature anomaly (Tho-D1, D2)
System error
Liquid flooding anomaly
System error
E16
E36
E37
E36-3
E37-1, 2, 3
Outdoor heat exchanger temperature thermistor (Tho-R) and sub cooling coil
E37-4, 5 E37temperature thermistor (Tho-SC, -H) anomaly
5, 6
E38
E38
E39
E39-1, 2
E40
E40
E41 (E51)
E42
Reference/Faults
E36-1, 2
Outdoor air temperature thermistor anomaly (Tho-A)
Thermistor wire breakage
Discharge pipe temperature thermistor anomaly (Tho-D1, D2)
Thermistor wire breakage
High pressure anomaly (63H1-1, 2 activated)
System error
E41 (E51)-1, 2 Power transistor overheat
E42-1, 2
E43
E43-1 E43-2
E45
E45-1, 2
E46
–
E48
E48-1, 2
E49
E49
Thermistor wire breakage
System error
Current cut (CM1, 2)
System error
Excessive number of indoor units connected, excessive total capacity of
connection
Site setting error
Communication error between inverter PCB and outdoor control PCB
Communication error
Mixed address setting methods coexistent in same network
Address setting error
Outdoor DC fan motor anomaly
DC fan motor error
Low pressure anomaly
System error
Thermistor wire breakage
E53/E55
E53/E55-1, 2
Suction pipe temperature thermistor anomaly (Tho-S), Under-dome temperature
thermistor anomaly (Tho-C1, C2)
E54
E54-1, E54-2
High pressure sensor (PSH)/Low pressure sensor (PSL) anomaly
Thermistor wire breakage
E56
E56-1, 2
Power transistor temperature thermistor anomaly (Tho-P1,Tho-P2)
Thermistor wire breakage
E58
E58-1, 2
Anomalous compressor by loss of synchronism
System error
E59
E59-1, 2
Compressor startup failure (CM1, 2)
System error
E60
E60-1, 2
Rotor position detection failure (CM1, 2)
System error
E61
E61
Communication error between the master unit and slave units
System error
E63
E63
Emergency stop
Site setting error
@amp_aircon |
amp-air-conditioning
190
Reference
Conditions & Conversions
Nominal and UK conditions
Pipe size
Nominal capacities (kW) specified in this price book
are calculated under ISO-T1 (JIS) standard conditions
as follows:
»»
»»
»»
»»
»»
»»
»»
»»
Cooling
Indoor temperature 27ºCDB, 19ºCWB
Outdoor temperature 35ºCDB
Heating
Indoor temperature 20ºCDB
Outdoor temperature 7ºCDB, 6ºCWB
1/4in = 6.35mm
3/8in = 9.52mm
1/2in = 12.70mm
5/8in = 15.88mm
3/4in = 19.05mm
7/8in = 22.22mm
11/8in = 28.58mm
13/8 = 34.93mm
Conversion data
UK cooling capacities (kW) specified in this price book
are calculated under the following conditions:
Indoor temperature 23ºCDB, 16º CWB
Outdoor temperature 30ºCDB
»»
»»
»»
»»
»»
kW x 3412 = btu/h
ºC x 1.8 + 32 = ºF
l/s x 3.6 = m3/h
bar x 14.51 = psi
m2 x 10.76 = ft2
UK heating capacities (kW) specified in this price
guide are calculated under the following conditions:
Indoor temperature: 22ºCDB
Outdoor temperature: -4ºCWB, -3ºCDB
Electrical
Information relating to local power supplies are
shown for guidance only and must be subject to IEE
regulations as well as site requirements. All three
phase supplies to be TPNE.
Energy labelling
All ENER - Lot 10 information is available at
www.mhi.co.jp/aircon/english/lot10/
ampair.co.uk | 01707 378 670 | [email protected]
191
Reference/Faults
Information included in this price book is for guidance only and does not form part of a contract.
Reference
Index | RAC & PAC Systems
Section
Indoor Unit
Outdoor Unit
Page
No
Section
Indoor Unit
Outdoor Unit
Page
No
RAC Systems
7
SRK50ZM-S
20
RAC Systems - Range Overview
8
SRK71ZR-S
20
Wall Mounted Standard Inverter
Wall Mounted Premium Inverter
SRK25ZMP-S
SRC25ZMP-S
9
SRK20ZMX-S
21
SRK35ZMP-S
SRC35ZMP-S
9
SRK25ZMX-S
21
SRK45ZMP-S
SRC45ZMP-S
9
SRK35ZMX-S
21
SRK20ZM-S
SRC20ZM-S
10
SRK50ZMX-S
21
SRK25ZM-S
SRC25ZM-S
10
SRK60ZMX-S
21
SRK35ZM-S
SRC35ZM-S
10
FDTC25VF
22
SRK50ZM-S
SRC50ZM-S
11
FDTC35VF
22
SRK63ZR-S
SRC63ZR-S
11
FDTC50VF
22
SCM Multi Split Indoor Units
Wall Mounted Hyper Inverter
Floor Standing Hyper Inverter
SRK71ZR-S
SRC71ZR-S
11
FDTC60VF
22
SRK80ZR-S
SRC80ZR-S
12
SRF25ZMX-S
23
SRK20ZMX-S
SRC20ZMX-S
13
SRF35ZMX-S
23
SRK25ZMX-S
SRC25ZMX-S
13
SRF50ZMX-S
23
SRK35ZMX-S
SRC35ZMX-S
13
FDUM50VF
23
SRK50ZMX-S
SRC50ZMX-S
14
FDEN50VF
23
SRK60ZMX-S
SRC60ZMX-S
14
SRR25ZM-S
24
SRF25ZMX-S
SRC25ZMX-S
15
SRR35ZM-S
24
SRF35ZMX-S
SRC35ZMX-S
15
SRR50ZM-S
24
SRF50ZMX-S
SRC50ZMX-S
15
SRR60ZM-S
24
SRR25ZM-S
SRC25ZMX-S
16
SRR35ZM-S
SRC35ZMX-S
16
SCM45ZM-S
Combination Tables
25
18
PAC Systems
39
SCM60ZM-S
18
PAC Systems - Range Overview
40
SCM80ZM-S
18
Compact Ducted Hyper Inverter
SCM Multi Split Outdoor Units
SRK71ZM-S
FDC71VNP
41
Wall Mounted Standard Inverter
Reference/Faults
SCM Multi Split Indoor Units
@amp_aircon |
SCM100ZM-S
19
SRK100ZR-S
FDC100VNP
42
SCM125ZM-S
19
FDTC25VF
SRC25ZMX-S
45
FDTC35VF
SRC35ZMX-S
45
FDTC40VF
SRC40ZMX-S
45
FDTC50VF
SRC50ZMX-S
46
SRK20ZM-S
20
SRK25ZM-S
20
SRK35ZM-S
20
amp-air-conditioning
FDTC Compact 4 Way Cassette
Hyper Inverter
192
Reference
Index | PAC Systems
Indoor Unit
Outdoor Unit
FDTC Compact 4 Way Cassette
Hyper Inverter
FDTC60VF
SRC60ZMX-S
46
FDT71VF1
FDC71VNP
48
FDT100VF2
FDC100VNP
48
FDT100VF1
FDC100VN
49
FDT125VF
FDC125VN
49
FDT 4 Way Cassette
Standard Inverter
FDT 4 Way Cassette Micro Inverter
Single Phase
FDT 4 Way Cassette Micro Inverter
Three Phase
FDT 4 Way Cassette Hyper Inverter
Single Phase
FDT 4 Way Cassette Hyper Inverter
Three Phase
FDUM Standard Ducted Standard
Inverter
FDUM Standard Ducted Micro
Inverter Single Phase
FDUM Standard Ducted Micro
Inverter Three Phase
FDUM Standard Ducted Hyper
Inverter Single Phase
Section
FDUM Standard Ducted Hyper
Inverter Single Phase
FDUM Standard Ducted Hyper
Inverter Three Phase
Page
No
Indoor Unit
Outdoor Unit
FDUM71VF1
FDC71VNX
60
FDUM100VF1
FDC100VNX
60
FDUM125VF
FDC125VNX
61
FDUM140VF
FDC140VNX
61
FDUM100VF1
FDC100VSX
62
FDUM125VF
FDC125VSX
62
FDUM140VF
FDC140VSX
62
FDU71VF1
FDC71VNP
64
FDT140VF
FDC140VN
49
FDT100VF1
FDC100VS
50
FDT125VF
FDC125VS
50
FDT140VF
FDC140VS
50
FDU100VF2
FDC100VNP
64
FDT40VF
SRC40ZMX-S
51
FDU100VF1
FDC100VN
65
FDT50VF
SRC50ZMX-S
51
FDU125VF
FDC125VN
65
FDT60VF
SRC60ZMX-S
51
FDU140VF
FDC140VN
65
FDT71VF1
FDC71VNX
52
FDU100VF1
FDC100VS
66
FDT100VF1
FDC100VNX
52
FDU125VF
FDC125VS
66
FDT125VF
FDC125VNX
53
FDU140VF
FDC140VS
66
FDT140VF
FDC140VNX
53
FDU200VF
FDC200VS
67
FDT100VF1
FDC100VSX
54
FDU250VF
FDC250VS
67
FDT125VF
FDC125VSX
54
FDU71VF1
FDC71VNX
68
FDT140VF
FDC140VSX
54
FDU100VF1
FDC100VNX
68
FDUM71VF1
FDC71VNP
56
FDU125VF
FDC125VNX
69
FDUM100VF2
FDC100VNP
56
FDU140VF
FDC140VNX
69
FDUM100VF1
FDC100VN
57
FDU100VF1
FDC100VSX
70
FDUM125VF
FDC125VN
57
FDU125VF
FDC125VSX
70
FDUM140VF
FDC140VN
57
FDU140VF
FDC140VSX
70
FDUM100VF1
FDC100VS
58
FDEN71VF1
FDC71VNP
72
FDUM125VF
FDC125VS
58
FDE100VG
FDC100VNP
72
FDUM140VF
FDC140VS
58
FDE100VG
FDEN125VF
73
FDC100VN
FDC125VN
73
FDEN140VF
FDC140VN
73
FDE100VG
FDC100VS
74
FDUM40VF
SRC40ZMX-S
59
FDUM50VF
SRC50ZMX-S
59
FDUM60VF
SRC60ZMX-S
59
FDU High Static Ducted
Standard Inverter
FDU High Static Ducted Micro
Inverter Single Phase
FDU High Static Ducted Micro
Inverter Three Phase
FDU High Static Ducted Hyper
Inverter Single Phase
FDU High Static Ducted Hyper
Inverter Three Phase
FDEN Ceiling Suspended
Standard Inverter
FDEN Ceiling Suspended Micro
Inverter Single Phase
FDEN Ceiling Suspended Micro
Inverter Three Phase
ampair.co.uk | 01707 378 670 | [email protected]
193
Reference/Faults
Page
No
Section
Reference
Index | PAC & VRF Systems
Section
FDEN Ceiling Suspended Micro
Inverter Three Phase
FDEN Ceiling Suspended Hyper
Inverter Single Phase
FDEN Ceiling Suspended Hyper
Inverter Three Phase
Page
No
Outdoor Unit
FDEN125VF
FDC125VS
74
VRF Systems
91
FDEN140VF
FDC140VS
74
VRF Outdoor - Overview
92
FDEN40VF
SRC40ZMX-S
75
VRF Outdoor - Unit Look Up
94
FDEN50VF
SRC50ZMX-S
75
FDF Floor Standing Micro Inverter
Three Phase
FDF Floor Standing Hyper Inverter
Single Phase
FDF Floor Standing Hyper Inverter
Three Phase
Section
Indoor Unit
Micro KX6 Heat Pump Outdoor Unis
Single Phase
Outdoor Unit
FDC112KXEN6
95
FDC140KXEN6
95
FDEN60VF
SRC60ZMX-S
75
FDEN71VF1
FDC71VNX
76
FDC155KXEN6
95
FDE100VG
FDC100VNX
76
FDC112KXES6
96
FDEN125VF
FDC125VNX
77
FDC140KXES6
96
FDEN140VF
FDC140VNX
77
FDC155KXES6
96
FDE100VG
FDC100VSX
78
FDC224KXE6
97
FDEN125VF
FDC125VSX
78
FDC280KXE6
97
FDEN140VF
FDC140VSX
78
FDC335KXE6
97
FDF71VD1
FDC71VNP
80
FDC224KXZPE1
98
FDF100VD2
FDC100VNP
80
FDC280KXZPE1
98
FDF100VD1
FDC100VN
81
FDC280KXZE1
99
FDF125VD
FDC125VN
81
FDC335KXZE1
99
FDF140VD
FDC140VN
81
FDC400KXZE1
99
FDF100VD1
FDC100VS
82
FDC450KXZE1
100
FDF125VD
FDC125VS
82
FDC475KXZE1
100
FDF140VD
FDC140VS
82
FDC500KXZE1
101
FDF71VD1
FDC71VNX
83
FDC560KXZE1
101
FDF100VD1
FDC100VNX
83
FDC615KXZE1
102
FDF Floor Standing Standard Inverter
FDF Floor Standing Micro Inverter
Single Phase
Page
No
Indoor Unit
Micro KX6 Heat Pump Outdoor Units
Three Phase
LITE KXZP Heat Pump Outdoor
Units
KXZ Heat Pump Outdoor Units
FDF125VD
FDC125VNX
84
FDC670KXZE1
102
FDF140VD
FDC140VNX
84
FDC735KXZE1
102
FDF100VD1
FDC100VSX
85
FDC800KXZE1
103
FDF125VD
FDC125VSX
85
FDC850KXZE1
103
FDF140VD
FDC140VSX
85
FDC900KXZE1
104
86
FDC950KXZE1
104
88
FDC1000KXZE1 104
Micro Inverter - Twin, Triple & Quad Systems
Reference/Faults
FDC1060KXZE1 105
@amp_aircon |
amp-air-conditioning
194
Reference
Index | VRF Systems
Section
Indoor Unit
Outdoor Unit
Page
No
Section
Indoor Unit
FDC1120KXZE1 105
Outdoor Unit
Page
No
FDC1300KXRE6 116
KXR6 Heat Recovery Outdoor Units
FDC1200KXZE1 106
FDC1250KXZE1 106
FDC1360KXRE6 116
R22 Renew
118
FDC1300KXZE1 106
FDCR224KXE6
119
FDCR280KXE6
119
Refresh KX Outdoor Units
FDC1350KXZE1 107
KXZ Heat Pump Outdoor Units
KXR6 Heat Recovery Outdoor Units
FDC1425KXZE1 107
PFD Boxes & Branch Pipes
120
FDC1450KXZE1 107
VRF Indoor - Overview
121
FDC1500KXZE1 108
VRF Indoor - UK Cooling Capacities
122
FDC1560KXZE1 108
VRF Indoor - UK Heating Capacities
123
FDC1620KXZE1 109
FDTQ22KXE6F
124
FDC1680KXZE1 109
FDTQ28KXE6F
124
FDTQ36KXE6F
124
1 Way Cassettes
FDC224KXRE6
110
FDC280KXRE6
110
FDTS45KXE6F
125
FDC335KXRE6
110
FDTS71KXE6F
125
FDC400KXRE6
111
FDTC22KXE6F
126
FDC450KXRE6
111
FDTC28KXE6F
126
FDC504KXRE6
111
FDTC36KXE6F
126
FDC560KXRE6
112
FDTC45KXE6F
127
FDC615KXRE6
112
FDTC56KXE6F
127
FDC680KXRE6
112
FDT28KXE6F
128
FDC735KXRE6
113
FDT36KXE6F
128
FDC800KXRE6
113
FDT45KXE6F
128
FDC850KXRE6
113
FDT56KXE6F
129
FDC900KXRE6
114
FDT71KXE6F
129
FDC960KXRE6
114
FDT90KXE6F
129
FDC1010KXRE6 114
FDT112KXE6F
130
FDC1065KXRE6 115
FDT140KXE6F
130
FDC1130KXRE6 115
FDT160KXE6F
130
FDTW28KXE6F
131
FDTW45KXE6F
131
4 Way Compact Cassettes
4 Way Cassettes
FDC1180KXRE6 115
FDC1235KXRE6 116
ampair.co.uk | 01707 378 670 | [email protected]
195
Reference/Faults
2 Way Cassettes
Reference
Index | VRF Systems & Air Handling/HRV
Section
2 Way Cassettes
Indoor Unit
Outdoor Unit
Page
No
Section
Indoor Unit
Outdoor Unit
Page
No
FDU160kXE6F
143
FDU224KXE6F
143
132
FDU280kXE6F
143
FDTW112KXE6F
133
FDK22KXE6F
144
FDTW140KXE6F
133
FDK28KXE6F
144
FDUM22KXE6F
134
FDK36KXE6F
144
FDTW56KXE6F
131
FDTW71KXE6F
132
FDTW90KXE6F
Hi Static Ducted
Wall Mounted
FDUM28KXE6F
134
FDK45KXE6F
145
FDUM36KXE6F
134
FDK56KXE6F
145
FDUM45KXE6F
135
FDK71KXE6F
145
FDUM56KXE6F
135
FDE36KXE6F
146
FDUM71KXE6F
135
FDE45KXE6F
146
FDUM90KXE6F
136
FDE56KXE6F
146
Standard Ducted
Ceiling Suspended
FDUM112KXE6F
136
FDE71KXE6F
147
FDUM140KXE6F
137
FDE112KXE6F
147
FDUM160kXE6F
137
FDE140KXE6F
147
FDUT22KXE6F-E
138
FDFU28KXE6F
148
FDUT28KXE6F-E
138
FDFU45KXE6F
148
Floor Standing Chassis
FDUT36KXE6F-E
138
FDFU56KXE6F
149
FDUT45KXE6F-E
139
FDFU71KXE6F
149
FDUT56KXE6F-E
139
FDFW28KXE6F
150
FDUT71KXE6F-E
139
FDFW45KXE6F
150
Low Static Ducted
Floor Standing Cabinet
Compact Ducted
FDUH22KXE6F
140
FDFW56KXE6F
151
FDUH28KXE6F
140
FDFL71KXE6F
151
FDUH36KXE6F
140
FDU45KXE6F
141
FDU56KXE6F
141
FDU71KXE6F
141
Reference/Faults
153
FDU500FKXE6F
154
FDU850FKXE6F
154
Outdoor Air Processing Unit
Hi Static Ducted
@amp_aircon |
Air Handling & HRV
FDU90KXE6F
142
FDU1300FKXE6F
155
FDU112KXE6F
142
FDU1800FKXE6F
155
FDU140KXE6F
142
SAF-DX250E6
156
amp-air-conditioning
SAF-DX Fresh Air Assembly
196
Reference
Index | Air Handling, Q-ton, Air to Water & Controls
Section
Indoor Unit
Outdoor Unit
Page
No
Page
No
Section
SAF-DX350E6
156
Q-ton
163
SAF-DX500E6
156
The Q-ton story
164
SAF-DX800E6
157
Why Q-ton?
165
SAF-DX1000E6
157
How it works
166
SAF Heat Recovery Ventilation Units
158
Specification & Accessories
168
KX EEV Valve Kits for AHU Connection
159
Air to Water Heat Pump
169
PAC Heat Exchanger Interface
FDC100VN
160
FDC125VN
160
FDC140VN
160
Controls
173
FDC100VS
160
Wired, Wireless & Infrared Controllers
174
FDC125VS
160
Wiring Adapters & Interfaces
175
FDC140VS
160
Centralised Remote Controllers
176
FDC200VS
160
SL4 Centralised Touch Screen Controller
177
FDC250VS
160
WEB & LON Works Gateways
178
FDC71VNX
161
BACnet Gateway
179
FDC100VNX
161
BMS Interfaces
180
FDC125VNX
161
Brackets, Trays, Cages & Other Accessories
181
FDC140VNX
161
FDC100VSX
161
AMP Diamonds
183
FDC125VSX
161
FDC140VSX
161
Reference/Faults
187
PAC Fault Codes
188
KX Fault Codes
190
Conditions & Conversions
191
ampair.co.uk | 01707 378 670 | [email protected]
197
Reference/Faults
SAF-DX Fresh Air Assembly
Reference
Reference/Faults
Notes
@amp_aircon |
amp-air-conditioning
198
Reference
ampair.co.uk | 01707 378 670 | [email protected]
199
Reference/Faults
Notes
Reference
Terms & Conditions
The use of this product guide is subject to the following
terms of use:
For more information about AMP or these terms and
conditions, please contact us:
The term ‘AMP Air Conditioning’, ‘AMP’, ‘AMP Air’, ’AMP
Diamonds’, ‘the Diamond scheme’ or ‘us’ or ‘we’ refers to AMP
Air Conditioning Limited. Our registered office is Blenheim
House, Blenheim Court, Brownfields, Welwyn Garden
City, Herts, AL7 1AD. Our company registration number is
2371708. The term ‘you’ or ‘your’ refers to the user or viewer
of our product guide.
Tel: Email: Address:
Reference/Faults
»» The content of this product guide is for your general
information and use only. It is subject to change
without notice and does not form part of any contract.
»» Prices within this guide are subject to change without
notice.
»» Neither we nor any third parties provide any warranty
or guarantee as to the accuracy, completeness or
suitability of the information and materials found
or offered in this product guide for any particular
purpose. You acknowledge that such information and
materials may contain inaccuracies or errors and we
expressly exclude liability for any such inaccuracies or
errors to the fullest extent permitted by law.
»» This product guide contains material which is owned
by or licensed to us. This material includes, but is
not limited to, the design, layout, look, appearance,
photographs and graphics. Reproduction is prohibited
other than in accordance with the copyright notice,
which forms part of these terms and conditions.
»» Product images within this product guide are for
illustrative purposes only and do not necessarily
represent the exact products, services or ideas in the
context in which they are found. Actual products may
differ from those shown.
»» All trademarks reproduced in this guide, which are not
the property of, or licensed to AMP, are acknowledged
in the guide.
»» Unauthorised use of this product guide may give to a
claim for damages and/or be a criminal offence.
»» This product guide provides links to third party
websites. These links are provided for your
convenience to provide further information. They do
not signify that we endorse the website(s). We have no
responsibility for the content of the linked website(s).
»» Your use of this product guide and any dispute arising
out of such use of the website is subject to the laws of
England and Wales.
»» In no event will we be liable for any loss or damage
including without limitation, indirect or consequential
loss or damage, or any loss or damage whatsoever
arising from loss of data or profits arising out of, or in
connection with, the use of this product guide.
@amp_aircon |
amp-air-conditioning
01707 378 670
[email protected]
AMP Air Conditioning
Blenheim House
Blenheim Court
Brownfields
Welwyn Garden City
Herts AL7 1AD
AMP Air Conditioning is an ISO 14001:2004 and 9001:2008
accredited company.
R
ISO 14001:2004
REGISTERED COMPANY
Certificate No. EN1749
R
ISO 9001:2008
REGISTERED COMPANY
Certificate No. CA14723
200
ampair.co.uk | 01707 378 670 | [email protected]
AMP Air Conditioning, Blenheim House, Blenheim Court, Brownfields, Welwyn Garden City, Herts AL7 1AD
© AMP Air Conditioning Ltd, 2016
Revised November 2016
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement

Languages