GDX Technologies Ltd GDX3 Installation Manual

Foreword

This manual is intended for the use of the installer only and should not be provided to the end user due to the nature of the information contained within it.

An entrance panel template is included within the manual for use in mounting the entrance panel.

© 2000 GDX Technologies Ltd. All Rights Reserved

Copyright in the whole and every part of this document, excluding the exceptions noted below, belongs to GDX

Technologies Ltd. and may not be used, sold, transferred, copied or reproduced in whole or in part in any manner or form or in or on any media to any person other than in accordance with the terms of the Owner’s Agreement or otherwise without the prior written consent of GDX Technologies Ltd.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 2 of 18

GDX Technologies Ltd GDX3 Installation Manual

Table of Contents

FOREWORD............................................................................................................................................................................................................ 2

TABLE OF CONTENTS ........................................................................................................................................................................................... 3

GENERAL DESCRIPTION....................................................................................................................................................................................... 4

GDX3 SYSTEM OVERVIEW ................................................................................................................................................................................... 5

CONTROLLER MASTER/SLAVE CARDS (9803/001)............................................................................................................................................. 6

C

ONTROLLER

M

ASTER

C

ARD

.................................................................................................................................................................................. 6

Links................................................................................................................................................................................................................ 6

Door Alarm ...................................................................................................................................................................................................... 6

Fuses .............................................................................................................................................................................................................. 6

C

ONTROLLER

S

LAVE

C

ARD

..................................................................................................................................................................................... 7

Links................................................................................................................................................................................................................ 7

COMPACT ENTRANCE PANEL (9903/001) ............................................................................................................................................................ 8

E

NTRANCE

P

ANEL TO

GDX3 C

ONTROL

R

ACK

C

ONNECTIONS

.................................................................................................................................... 8

E

NTRANCE

P

ANEL

L

INKS

........................................................................................................................................................................................ 8

V

OLUME

C

ONTROLS

............................................................................................................................................................................................... 9

L

OCKS

.................................................................................................................................................................................................................. 9

D

OOR

C

ONTACTS

.................................................................................................................................................................................................. 9

F

IRE

S

WITCH

....................................................................................................................................................................................................... 10

Fail Open Locks ............................................................................................................................................................................................ 10

Fail Closed Locks. ......................................................................................................................................................................................... 10

P

USH TO

E

XIT

(PTE)............................................................................................................................................................................................ 10

Fail Open Locks ............................................................................................................................................................................................ 10

Fail Closed Locks .......................................................................................................................................................................................... 10

T

OKEN

A

CCESS

C

ONNECTIONS

............................................................................................................................................................................. 11

PAC Easikey Connections............................................................................................................................................................................. 11

I

NTERFACING TO A

S

TANDALONE

E

ASIKEY

R

EADER

................................................................................................................................................ 12

Fail Open Locks ............................................................................................................................................................................................ 12

Fail Closed Locks .......................................................................................................................................................................................... 12

E

NTRANCE

P

ANEL

LCD M

ESSAGES

...................................................................................................................................................................... 13

TELEPHONE HANDSETS (9701/001) (CODE 23150)........................................................................................................................................... 14

C

ONNECTIONS TO

GDX3 C

ONTROL

R

ACK

............................................................................................................................................................. 14

C

ONNECTING MORE THAN ONE

H

ANDSET TO A

TEL P

OSITION

................................................................................................................................. 14

PROGRAMMING THE CONTROLLER IN GENERAL ........................................................................................................................................... 15

SETUP (PREVIOUS) ......................................................................................................................................................................................... 15

TIME/DATA (NEXT)........................................................................................................................................................................................... 15

CHANGE ........................................................................................................................................................................................................... 15

CANCEL ............................................................................................................................................................................................................ 15

SERVICE PERIODS .............................................................................................................................................................................................. 15

ALTERING AND CONFIGURING THE SET-UP..................................................................................................................................................... 16

S

ERVICE

P

ERIODS AND

T

IMED

P

ROCESSES

............................................................................................................................................................ 16

S

ETTING THE

D

ATE

/T

IME AND

T

ONE

...................................................................................................................................................................... 17

N

ORMAL

D

ISPLAY

................................................................................................................................................................................................. 17

AUTOMATIC BST/GMT ADJUSTMENT. ............................................................................................................................................................... 17

OPERATION .......................................................................................................................................................................................................... 18

N

ORMAL

O

PERATION

............................................................................................................................................................................................ 18

T

AILGATING

. ........................................................................................................................................................................................................ 18

D

UAL

D

OOR

O

PERATION

. ..................................................................................................................................................................................... 18

C

ANCELLING THE

C

ALL

......................................................................................................................................................................................... 18

S

ERVICE

B

UTTON

................................................................................................................................................................................................ 18

S

TUCK

B

UTTONS

................................................................................................................................................................................................. 18

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 3 of 18

GDX Technologies Ltd GDX3 Installation Manual

General Description

The GDX3 Door Entry system is a door entry system with some excellent additional features. The basic system comprises of two boards; the Controller (9803/001) and the Entrance Panel (9603/003). All hardware is configured using non-solder type miniature jumpers making set-up simple and fast. The system operates with GDX3 Tone Handsets (Order No 23150).

Ø Up to 24 Handsets

Ø Two Door Operation

Ø Illuminated LCD‘s

Ø Five Programmable Service Periods one of which is Day Specific

Ø Optional Sunday Service

Ø Programable Date & Time

Ø Programable Door Alarm Period

Ø Programable Post and Pre-Answer Durations

Ø Programable Lock Open Duration

Ø Automatic BST/GMT adjustment

Ø Programable Ring Tone

Ø Battery Backup as Standard

Ø Easikey Interface

Ø EMC Compliance Tested

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 4 of 18

GDX Technologies Ltd GDX3 Installation Manual

GDX3 System Overview

The GDX3 Door Entry system can vary from a single door 8-way system to a two door 24-way system as shown below.

Handsets

17-24

Handsets

9-16

Slave 9803/001

Slave 9803/001

Controller

9803/001

Handsets

1-8

Door 0

9903/001

Door 1

9903/001

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 5 of 18

GDX Technologies Ltd GDX3 Installation Manual

Controller Master/Slave Cards (9803/001)

This board is used to control all audio routing and timing within the GDX3 System. The board may be used as a C

ONTROLLER or as a S

LAVE

. (The C

ONTROLLER

being fully populated)

Controller Master Card

Links

The C

ONTROLLER

controls Flats 1 – 8 as well as providing the facility to alter the Service Periods, Date, Time etc. as will be explained later in this document. Links 2,

3, 4 and 5 should be arranged as shown in the table opposite. LK1 on the C

ONTROLLER

is used to impedance match the serial bus. This link should only

be fitted for single Door Systems.

FLATS

1 - 8

LK2

IN

LK3

OUT

LK4

IN

LK5

OUT

Door Alarm

In the event that the Door has been left open for longer than the user defined period the DOOR ALARM output will switch [email protected]

max. to a remote indicator (NB. The maximum current available from this output is dependant on the Power Supply used.). The Door Contacts on the Entrance Panel must be used to enable this feature.

Fuses

The fuses located on the master card are as follows :

Location Value

FS14 500mA

FS15

FS16

FS17

FS18

500mA

3A

500mA

500mA

Type

20mm Anti Surge

20mm Quick Blow

20mm Anti Surge

20mm Quick Blow

20mm Quick Blow

Description

24V Main Supply Input Fuse

Ring Tone Supply Fuse

12V Main Supply Input Fuse

CANH Data Line Fuse

CANL Data Line Fuse

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 6 of 18

GDX Technologies Ltd GDX3 Installation Manual

Controller Master/Slave Cards (9803/001)

Controller Slave Card

Links

The S

LAVE

can control Flats 9 – 16 or Flats 17 – 24 depending on the position of Links 2, 3, 4 and 5 as outlined in the table opposite.

Please Note

FLATS

9 - 16

17 - 24

Power should be removed from the system before configuration.

LK2 LK3

OUT IN

IN

LK4

IN

OUT OUT

LK5

OUT

IN

LK1

LK2 LK3 LK4 LK5

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 7 of 18

GDX Technologies Ltd GDX3 Installation Manual

Compact Entrance Panel (9903/001)

Entrance Panel to GDX3 Control Rack Connections

The connections required from the entrance panel(s) to the control rack are as follows ;-

Ø 12Vdc Electronics Power

Ø 12Vdc Lock Power

Ø Audio

Ø Data

Ø Token Access (If Applicable)

The actual connections required are detailed on the drawings included at the end of this manual.

The colour codes given on the drawings should be followed.

In addition the following can be connected directly into the entrance panel as and if required ;-

Ø Door Lock Release

Ø Push To Exit Switch (PTE)

Ø Fire Switch

Ø Door Contact

Again the actual connections required are detailed on the drawings included at the end of this manual.

Entrance Panel Links

Two links are used to configure the Entrance Panel. Their function is described in the tables below. There is no requirement to remove power or to reset the unit for new link settings to become effective on the entrance panel. The links are visible through the aperture in the panel chassis when the faceplate is removed.

Please Note

Please ensure that the correct door is connected to the correct terminations on the GDX3 Control Rack. i.e. The door with LK1 fitted should be connected to the DOOR 0 position and the door with LK1 not fitted should be connected to the DOOR 1 position. If this is not correct then no audio will switch from the entrance panel to the handset through the control rack when the handset is called.

LK1 : Door Number Select Link

Link On Pins 1 & 2

Door 0 Selected

LK2 : Lock Type Select Link

Link On Pins 1 & 2

Fail Open Lock Selected

Link On Pins 2 & 3

Door 1 Selected

Link On Pins 2 & 3

Fail Closed Lock Selected

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 8 of 18

GDX Technologies Ltd GDX3 Installation Manual

Compact Entrance Panel (9903/001) (continued)

Volume Controls

The Speaker Volume, Tone Volume at the entrance panel and MIC volume can be altered using the potentiometers on the entrance panel.

Firstly the Speaker and Mic controls should be set to suit the background noise levels and then the volume of the Tone at the entrance panel should be adjusted.

Locks

The door lock supply for each door is fused at 1.1 Amp within the control rack.

Power for the locks must be run on its own power cabling such as a 0.5mm flex (depending on lock power consumption and cable distances). The lock power must not be run within the same cable as the entrance panel power, data or audio - or the back emf voltage spikes when the lock is operated may interfere with the operation of the panel or control rack and may even cause permanent damage to the equipment.

Manufacturers guidelines as to the fitting of suppression devices across the door locks must be followed – this is essential to prevent damage to the equipment.

As mentioned previously, two lock types may be operated from the GDX3 system ;-

Ø 12Vdc Apply Power to Unlock (Fail Closed)

Ø 12Vdc Remove Power to Unlock (Fail Open)

The current available for the locks is as described in the following table:-

System

8 Way Control Rack

8 Way Control Rack with Easikey

16 Way Control Rack

16 Way Control Rack with Easikey

Recommended Maximum Total Lock Current (Amps)

2.3A PSU 4.3A PSU

1.9

1.5

1.8

1.4

3.9

3.5

3.8

3.4

Please ensure that LK2 at the Entrance Panel board (9903/001) reflects the type of Lock being used.

Door Contacts

The Door Contacts are NC inputs. If terminations are not used then short with a link.

If tailgating or door alarm indication is required then these contacts must be used to provide these facilities.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 9 of 18

GDX Technologies Ltd GDX3 Installation Manual

Compact Entrance Panel (9903/001) (Continued)

Fire Switch

Fail Open Locks

The Fire Switch inputs are NC inputs. On breaking the Fire Switch the power is physically removed from the locks. For this reason the Fire Switch should only be used with Fail Open locks. When the fire switch is activated an audible tone is heard, for approximately two minutes. The Fire Switch should not be

paralleled directly with the Fire Switch inputs of any other unit, a two pole NC fire switch must be used for two door applications.

Note: The power for the locks is routed via the fire switch therefore the cabling used must be capable of carrying the Lock current.

If the Fire Switch terminations are not used then short with a link.

Fail Closed Locks.

A Fire Switch can only be used with Fail Open locks – the Fire Switch terminations should be shorted with a link.

Push to Exit (PTE)

Fail Open Locks

The PTE inputs are NC inputs. On pressing the PTE button the lock is released for a duration of approx. 8 seconds. These inputs provide additional safety when using Fail Open locks as they physically break the lock supply for the duration of time that the button is pressed.

Note: The power for the locks is routed via the PTE switch therefore the cabling used must be capable of carrying the Lock current.

If the Push to Exit terminations are not used then short with a link

Fail Closed Locks

Normally in the case of a fail closed lock type a mechanical release handle will be used on the inside of the door and the Push To Exit terminations on the panel should be shorted out with a link.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 10 of 18

GDX Technologies Ltd GDX3 Installation Manual

Compact Entrance Panel (9903/001) (Continued)

Token Access Connections

With the addition of token access facilities onto the GDX3 door entry system the door entrance panel is still used to operate the door lock and the token access controller is used only to switch the entrance panel when a valid token is presented to one if its readers.

This is achieved by means of a single connection into the token access input on the entrance panel - activated by applying +12V to the + E-KEY input on the panel with respect to 0V (Ground). In effect the lock ouput from the token access controller is used to activate the door panel instead of operating the door lock directly.

PAC Easikey Connections

Connect a PAC Easikey controller onto the GDX3 System as follows.

Note : The cabling for the Easikey reader must be separate from any other entrance panel cabling

or the noise of the reader will be picked up on the door entry system audio.

P1

ENTRANCE

PANEL

L1

L2

+

E-Key

CHANNEL 1

-V1

S1

R1

A1

+V1

-V

SIG

VCA

+V

EASIKEY

READER

EASIKEY

CONTROLLER

The Lock Time on the Easikey Controller should be set to two seconds Normally Open. (02)

If adding a second panel then use the same connections as above for reader channel 2.

If a stand alone token reader is used on the second reader channel then use the token controller to switch the lock directly as per the manual supplied with the controller and as illustrated below ;-

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 11 of 18

GDX Technologies Ltd GDX3 Installation Manual

Compact Entrance Panel (9903/001) (Continued)

Interfacing to a Standalone Easikey Reader

Fail Open Locks

The connection diagram opposite illustrates how to interface the second channel of the Easikey Controller to a stand alone token access reader (The first channel being used for a reader built into the Door 0 entry panel) A double pole Push to Exit switch is used to ensure that the lock is operated in the event of Control Rack failure.

Set Channel 2 Lock Time on the Easikey

Controller to 56 (6 seconds NC) for correct operation.

Ensure that a MOV (Metal Oxide

Varistor) is fitted directly across the

LOCK supply at the Lock.

Fail Closed Locks

The connection diagram opposite illustrates how to interface the second channel of the Easikey Controller to a stand alone token access reader (The first channel being used for a reader built into the Door 0 entry panel)

Set Channel 2 Lock Time on the Easikey

Controller to 06 (6 seconds NO) for correct operation.

Ensure that a MOV (Metal Oxide

Varistor) is fitted directly across the

LOCK supply at the Lock

Note : This is not a Fail Safe configuration.

DOOR LOCK

NO

+

CW1308

NO

+

CW1308

-

-

R2

0.5mm FLEX

-V2 L4

NC

L3

EASIKEY

CONTROLER

CHANNEL 2

DOOR LOCK

R2 -V2 L4 L3

EASIKEY

CONTROLER

CHANNEL 2

0.5mm FLEX

0.5mm FLEX

LOCK 12V

LOCK 0V

GDX3 CONTROL

RACK

LOCK 12V

LOCK 0V

GDX3 CONTROL

RACK

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 12 of 18

GDX Technologies Ltd GDX3 Installation Manual

Compact Entrance Panel (9903/001) (Continued)

Entrance Panel LCD Messages

The entrance panel LCD display provides various text messages for user information and reassurance. It does also provide certain engineering information as well however that can be of assistance if there is a reported problem with the system.

At power up or entrance panel reset the following information is displayed in order on the LCD :

VERSION GDX3EP5

DOOR NUMBER 0

FAIL OPEN LOCK

SYSTEM READY …

The version information displayed is the software version of the entrance panel itself.

The door number displayed should match up with the door channel in the control rack into which that door is wired – if it is not then although the call will appear to be put through to the handset there will be no audio.

When “System Ready …” is displayed the entrance panel has successfully connected to the control rack. If however the following is displayed then the entrance panel has not been able to connect into the control rack because of a data communication problem of some kind (see troubleshooting section).

CONNECTING …

If the letters “SB” are displayed at the right hand corner of the LCD after it connects to the control rack this indicates that the entrance panel has detected a stuck button on the entrance panel faceplate. This may indeed be due to a stuck button but it may be due to a short on the button wiring loom (see troubleshooting section).

When a handset is called from the entrance panel the following should be displayed on the LCD :

FLAT CALLED …

When the handset is answered the following should be displayed on the LCD :

CALL ANSWERED …

When the handset is replaced on hook the following should be displayed again on the LCD :

SYSTEM READY …

If however the message “Call Answered …” appears immediately the handset is called then either the handset has been left Off Hook or there is a cable fault to the handset.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 13 of 18

GDX Technologies Ltd GDX3 Installation Manual

Telephone Handsets (9701/001) (Code 23150)

Connections to GDX3 Control Rack

When using the GDX3 Tone handset the connections are as shown below ;-

4 Pair CW1308 telephone cable should be used for the handset with the colour code as illustrated.

1 2 3 4 5 6 D

4 PAIR CW1308

TELEPHONE

CABLE

1 2 3 4 5 6 D

N.B. LK1 on the handset should not be removed.

Line Function

1

2

Audio Phone to

Door

Audio Door to

Phone

Colour

WHITE/blue

BLUE/white

5

Phone Lock

Open Control

WHITE/green

Connecting more than one Handset to a TEL Position

To install a second handset simply make a connection between ‘1’, ’2’, ’3’, ’4’, ’5’, ’6’, ‘D’ and ‘EX PRIV’ of the two handsets using CW1308 cable.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 14 of 18

GDX Technologies Ltd GDX3 Installation Manual

Programming The Controller In General

Programming of the system is carried out on the

C

ONTROLLER

board 9803/001 by the use of four buttons.

SETUP

(PREVIOUS)

TIME/DATE

(NEXT)

CHANGE CANCEL

SETUP (PREVIOUS)

This button invokes the main Set-up procedure for setting service periods and the various timed processes.

During data entry it is used to move the focus back one character.

TIME/DATA (NEXT)

This button invokes the alteration of the Date, Time and Tone procedure. During data entry it is used to move the focus forward one character.

CHANGE

This button is used to change the setting currently in focus. When pressed during normal operation the system will display all currently set options.

CANCEL

This button is used to cancel the current operation.

Service Periods

There are five service periods. Four of which may be configured to occur everyday including/excluding a

Sunday. The fifth service period is specified for a particular day and is independent of whither Sunday

Service has been selected or not. All service periods must be configured with valid times. To disable a service period simply make the ON time the same as the OFF time. All service periods are checked after entry and if an error is detected the user is requested to re-enter the service periods. After the five service periods have been configured the user is presented with the option of Sunday Service. Note that the Sunday service setting only applies to Service Periods 1 to 4. The default for Sunday service is OFF

Service

Period

Type Duration (max) Effective Sunday Service

1 to 4 Standard 24 Hours On all Days Optional

5 Non Standard 24 Hours On Specified Day Not Applicable

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 15 of 18

GDX Technologies Ltd GDX3 Installation Manual

Altering and Configuring the Set-Up

Service Periods and Timed Processes

To begin alteration of the current Setup press the 'SETUP' button. The Screen displays the first service period as shown.

The option that is currently flashing on the display is now under review and may be changed using the 'CHANGE' button. When the user is happy with this setting the 'NEXT' button should be pressed to move the focus on to the next option. Pressing the

‘PREVIOUS’ button will move to the last altered entry. The fifth service period display differs from the first four in that the 'active day' is displayed in location 2 of the display.

When all five service periods have been configured the user is presented with the

Sunday Service option. To switch the Sunday Service ON and OFF use the

‘CHANGE’ button. When satisfied with the selection press the 'NEXT' button.

The user is then requested to enter the Pre-Answer Time in Seconds. This is the time allocated for the call to be answered. This time may range between 0 and 99 seconds. To alter the time use the 'CHANGE', ‘NEXT’ and ‘PREVIOUS’ buttons as before.

After setting the Pre-Answer time the user is requested to enter the Post-Answer

Time in Seconds. Again this time may range from 0 to 99 seconds and is the allowable talk time after the call has been answered. To alter the time use the

'CHANGE', ‘NEXT’ and ‘PREVIOUS’ buttons as before.

The next setting is the Lock Open duration. Again this may be configured in the range

0 to 99 seconds. The time is again altered by the use of the 'CHANGE', ‘NEXT’ and

‘PREVIOUS’ buttons.

After setting the Lock Open duration the user will then be requested to enter the

Alarm Timeout period. This is the Time duration that the system will wait after the

Door Contacts indicate that a door is open before activating the alarm. The time is entered in minutes and may range from 0 to 99 minutes. To alter the Alarm duration use the 'CHANGE', ‘NEXT’ and ‘PREVIOUS’ buttons as before.

On completion the display should then indicate that Checking is in progress. If there are no errors with the data input the Normal Display, as explained later, is resumed.

If at any time during the Set-up procedure the user wishes to abort input simply press the 'CANCEL' button or avoid data entry for 30 seconds.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 16 of 18

GDX Technologies Ltd GDX3 Installation Manual

Setting the Date/Time and Tone

By pressing the ‘TIME/DATE’ Button the user may alter not only the Date and Time but also the Selected

Call Tone. After pressing the ‘TIME/DATE' Button the first character of the display will be flashing. This is the Tone Select Option. The user may select from three Call Tones A, B or C the default being A. As before the 'CHANGE' Button is used to change the setting, the 'NEXT' Button is used to move the focus to the next option and the ‘PREVIOUS’ button is used to move the focus onto the previous option.

After selecting the desired Call Tone the user may now set-up the Day of the Week and the current Date and Time using the 'CHANGE', ‘NEXT’ and ‘PREVIOUS’ Buttons. When the minutes have been set-up and the 'NEXT' Button is pressed the Time will begin to increment in a normal fashion.

If at any time during the Date/Time Set-up procedure the user wishes to abort input simply press the

‘CANCEL' button or avoid data entry for 30 seconds.

Normal Display.

The Normal Display is displayed continuously during idle operation. The display contains information regarding which Tone has been selected, the day of the week, date, time, whither Sunday Service has been selected and if the current time falls within a defined service period.

A flashing symbol in location 4 of the display indicates that the current time falls within a service period. Similarly a flashing

in location 4 of the display indicates that Sunday Service is

ON. Both symbols may be flashing alternately reflecting the current system status at the current time.

Location 1 of the display is used to indicate the function of the door being opened by the use of the following symbols: -

Door opened by handset.

Door opened by action of Service button on Entrance Panel

Service button pressed but access denied.

Automatic BST/GMT Adjustment.

The daylight saving function of the Electronic Timeclock provides automatic adjustment of the time when changing from BST to GMT and visa versa. On the first Sunday in April the time increments from 1:59:59AM to 3:00:00AM and on the last Sunday in October when the time first reaches 1:59:59AM it changes to

1:00:00AM.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 17 of 18

GDX Technologies Ltd GDX3 Installation Manual

Operation

Normal Operation.

Pressing a button at the Entrance Panel will result in the handset in the selected occupants’s apartment ringing for the duration of time that the button is pressed. On lifting the receiver, full duplex audio communication will be established between the occupant and the caller at the Entrance Panel. The occupant may then operate the Open Door button on their Telephone to release the lock.

Tailgating.

If the Door Contacts are used on the Entrance Panel then the door will be locked on closing.

Dual Door Operation.

If a call is currently active from one of the Entrance Panels and a call is made from the other Entrance Panel then the second caller is requested to wait. An engaged tone will be heard.

When the first call is complete then call from the second Entrance Panel is routed to the desired apartment and the call tone is enabled for a duration of approx. 3 seconds. The caller may then re-press the selected button to ring the handset again.

Cancelling the Call

The Call from a door may be terminated in several ways.

· The Pre or Post Answer Times have been exceeded

· The lock activation time has ended

· The handset has been replaced on-hook

Service Button

On pressing the service button on the entrance panel the system will check if the current time falls within a valid service period. If it does then the Lock will be opened, the entrance panel will display ‘Door Open ‘ and a tone will sound for the lock duration. If it does not then the Entrance Panel will display ‘No Access’ and the no access tones will be heard.

Stuck Buttons

In the event of a button being stuck in the ON position the system will temporarily mask the button until the button has been released. All other buttons will behave as normal during the fault. A flashing ‘S’ ‘B’ in the corner of the display will indicate that a button is stuck.

Revision No : 6.00 Revision Date : 2 nd

August 2000 ã GDX Technologies Ltd Page 18 of 18

GDX3 DOOR ENTRY SYSTEM CONTROL RACK & COMPACT ENTRANCE PANEL CONNECTION SCHEMATIC

PLEASE FOLLOW THE WIRING COLOUR CODES QUOTED ON THIS DRAWING

1

TELEPHONE HANDSET 1

2 3 4 5 6 D CONNECTIONS FOR HANDSETS

9 TO 16 AND 17 TO 24 ARE

IDENTICAL FROM THE 8 WAY

GDX3 SLAVE CONTROL CARDS

WH/

BL

BL/

WH

WH/

OR

OR/

WH

WH/

GRN

GRN/

WH

WH/

BRN

1 x 4 PAIR CW1308

TELEPHONE CABLE

TELEPHONE HANDSET 8

1 2 3 4 5 6 D

CABLING NOTE

The cabling specifications quoted are not valid for underground cabling - suitable underground cabling must be used in this case.

WH/

BL

BL/

WH

WH/

OR

OR/

WH

WH/

GRN

GRN/

WH

WH/

BRN

1 x 4 PAIR CW1308

TELEPHONE CABLE

1 2

3 4

TEL 1

5 6 D

GDX3 8 WAY MASTER CONTROL CARD

LOCK

12V OV

DOOR 0 CONNECTIONS

DOOR

12V 0V

DATA

CANH CANL

AUDIO

1 2

1 2

3 4

TEL 8

5 6 D

LOCK

12V OV

DOOR 1 CONNECTIONS

DOOR

12V 0V

DATA

CANH CANL

AUDIO

1 2

WH/

BL

BL/

WH

WH/

OR

OR/

WH

WH/

GRN

GRN/

WH

CONNECTIONS FOR DOOR 1 AS FOR DOOR 0

1 x 2 CORE 0.5mm

FLEX (FOR LOCK)

GDX3 COMPACT DOOR CONTROL CARD PRINTED CIRCUIT BOARD (9903/001)

(PLEASE NOTE LINK FOR SELECTING DOOR 0 AND DOOR 1 ON THE DOOR CARD)

CONTROL RACK CONNECTIONS

LOCK

+12V OV

DOOR

12V 0V

DATA

CANH CANL

AUDIO

IN(1) OUT(2)

LOCK OUT

+12V 0V

AUXILIARY CONNECTIONS

NC CONTACT

DOOR

NC CONTACT

FIRE SWITCH

NC CONTACT

PUSH TO EXIT

E/KEY

+

WH/

BL

BL/

WH

WH/

OR

OR/

WH

WH/

GRN

GRN/

WH

WH/

BR

SEE NOTE

1 x 6 PAIR CW1308 TELEPHONE CABLE

CONNECTIONS SHOWN FOR AN EASIKEY 99 CONTROLLER.

(FOR ANY OTHER CONTROLLER FOLLOW THE MANUFACTURERS

INSTRUCTIONS AND APPLY THE PRINCIPLE ILLUSTRATED

BELOW OF TRIGGERING THE ENTRANCE PANEL "E/KEY+" INPUT.

P 1 P 2 L1 L2

CHANNEL 1

-V1 S1 R1 A1 +V1 L3 L4

CHANNEL 2

-V2 S2 R2 A2 +V2

AS PER READER 1

CONTROLLER

-V1

S1

A1

+V1

READER 1

-V

SIG

VCA

+V

1 x 6 CORE SECURITY CABLE

(MUST BE SEPARATE CABLE)

SEE NOTE

DOOR 0

TOKEN

READER

+V SIG

-V VCA

LOCK

RELEASE

DOOR FIREMANS

CONTACT SWITCH

PUSH TO

EXIT

IT IS ESSENTIAL TO FIT AN MOV ACROSS THE LOCK

AS THE LOCK RELEASE, PUSH TO EXIT AND FIREMAN'S SWITCH ALL

CARRY THE LOCK CURRENT THEY SHOULD BE RATED ACCORDINGLY ie. 0.5mm 2 CORE FLEX TO EACH ONE. (DOES NOT APPLY TO CONTACT)

NOTE : THE CONNECTION FROM E/KEY + TO THE TOKEN ACCESS CONTROLLER

SHOULD BE TAKEN TO ON THE MAIN ENTRANCE PANEL CW1308 CABLE.

THE CONTACT ON THE TOKEN CONTROLLER IS USED TO SWITCH A

+12V DC INTO THE GDX ENTRANCE PANEL INSTEAD OF THE LOCK DIRECTLY

(SET THE TOKEN CONTROLLER TO A FAIL CLOSED LOCK TYPE)

GDX Technologies Ltd

Anchor Mills, Seedhill,

Paisley Renfrewshire. PA1 1TJ

GDX3 EP CONNECTIONS 2.sdr Ver 1.02 01/08/00

advertisement

Key Features

  • Up to 24 Handsets
  • Two Door Operation
  • Illuminated LCDs
  • Five Programmable Service Periods
  • Optional Sunday Service
  • Programable Date & Time
  • Programable Door Alarm Period
  • Programable Post and Pre-Answer Durations
  • Programable Lock Open Duration
  • Automatic BST/GMT adjustment

Related manuals

Frequently Answers and Questions

What is the maximum number of handsets that can be used with the GDX3 system?
The GDX3 system can support up to 24 handsets.
How many doors can be controlled by the GDX3 system?
The GDX3 system can control up to two doors.
What is the purpose of the illuminated LCDs on the entrance panel?
The entrance panel LCD provides various text messages for user information and reassurance.
What are the different types of locks that can be used with the GDX3 system?
The GDX3 system can be used with both Apply Power to Unlock (Fail Closed) and Remove Power to Unlock (Fail Open) locks.