Catalog Temperature, Pressure, Humidity

Catalog Temperature, Pressure, Humidity
HUMIDITY · TEMPERATURE · Pressure
T H E W O R L D O F W E A T H E R D A T A
THE WORLD OF WEATHER DATA
Measurement and Documentation:
Thies’ range of service for meteorology,
environmental protection and industry
Today more than ever the
measurement, processing and
analysis of meteorological
data requires a high degree of
measurement instrument precision and an optimal
adaptation of the data
acquired to the task at hand.
For more than 60 years, we
have been developing, producing and supplying practical
instruments and systems for
the analysis of weather data.
Today, we are one of the
world’s largest suppliers
of such equipment.
Our close cooperation with
scientific institutions and
governmental agencies in
many countries guarantees a
constant and up-to-date flow
of information about all
aspects of individual national
problems and projects and
the rapid implementation of
state-of-the-art developments
and measurement techniques.
Our instruments and systems
fulfil in all respects both to the
requirements of national weather services as well as those
of the World Meteorological
Organization in Geneva.
Meteorological observations
without computer-aided measurement and documentation
systems are unthinkable
today.
THIES develops complete
ready-for-use-systems which
include precision data transmitters, data loggers, power
supply units and personal
computers with adapted software. Humidity, Temperature, Pressure
Table of Contents
Humidity
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Psychrometer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recording Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Control Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Transmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
4
6
7
8
Temperature
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recording Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Transmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3
1
14
16
17
Air Pressure
Glossary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aneroid Barometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mercury Barometers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recording Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
2
22
22
23
24
Humidity, Temperature, Pressure
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recording Instruments . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electronic Hand Instruments . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Transmitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clima Sensors D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weather Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7
2
27
30
31
34
35
Accessories
8
3
38
39
41
Weather and Thermal Radiation Shield . . . . . . . . . . . . . . . . . . .
Measuring Transformer . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hangers / Holders / Adapters . . . . . . . . . . . . . . . . . . . . . . . . .
1
Beyond the meteorology the measurement and regulation of air humidity is an
essential element of the climatic technology. Humidity control in closed rooms
as for example swimming baths, offices
or living-rooms creates a comfor­table
atmosphere for man and helps considerably to save energy. The right humidity
determines also the ideal climate for
delicate goods in storerooms and dehumidifying plants, and improves by this
the product quality and durability.
In the rural meteorology and en­vironmental technique humidity measurements in the open field are undeniable
for the planning of ­irrigation and
humidifying, for the determination y
of the optimum seed and planting as
well as for the c­ ontrol of micro climate.
2
Humidity
Glossary
Absolute humidity
Capacitive measurement
element
Indicates how many grams [g/m³] of water vapour are included in one cubic meter of air. (at 0 °C max. 5 g/m3, at 20 °C approx. 17 g/m3)
An arrangement in which a change in the relative humidity leads to a change
in the electrical capacity. For example the capacity of a polymer film
on a carrier material changes when water vapour is absorbed.
Dew point
Dry bulb temperature The ambient temperature measured on the dry ventilated thermometer of
a psychrometer.
Hygro transmitter General term for humidity measurement instruments with an electrical
measured value output.
Hygrograph Measurement instrument which mechanically records the relative humidity
as a function of time.
Hygrometer General term for indicating humidity measuring instruments.
Hygrostat Humidity-dependent switching instrument to regulate moistening or
dehydrating devices or to trigger warning signals indicating too little or too much moisture in moisture-sensitive installations.
Temperature [°C, K], to which the mixture of air and water vapour has to cool down, so that the air is just saturated with the available amount of water vapour, and condensation is starting.
At 15 °C and 50% rel. humidity the dew point is about 5 °C,
at 80% rel. humidity about 12 °C, and at a humidity of 100% the dew point corresponds to the current temperature of 15 °C.
Measurement element H Specially prepared human hairs expand under the influence of humidity, thus
changing in length. This change in length is a measure of relative humidity. The range of application lies between 10 and 100% rel. humidity in temperatures ranging from -60 ... +70 °C. Hair measurement elements must be
regenerated.
Measurement element K Under the influence of humidity, specially prepared synthetic fibers change in length. This change in length is a measure of relative humidity. The range of application lies between 0 and 100% rel. humidity in temperatures ranging from 0 ... +100 °C.
Psychrometer A measurement instrument with which the humidity of the atmosphere
can be measured by measuring the dry bulb temperature, and the wet bulb
­temperature, and applying the psychrometric equation. Owing to the good
measurement accuracy attainable, it is also used as a reference instrument.
Pt 100 Sensor
A temperature sensor with a measurement coil made of platinum wire.
The temperature-dependent resistance-change of the platinum wire is used
as measure for the temperature. 100 Ω for 0 °C is used as basic value.
The resistance-change is defined in the DIN IEC 60751 standard.
Pt 100 sensors are applied for ex. in psychro transmitters.
Relative humidity
Indicates the ratio in percent [%] of the instantaneous content of water vapour in the atmosphere to the maximum possible content of water vapour at the same temperature.
Tensiometer Measurement instrument to measure the saturation potential of the soil
(water requirement of soils). Important to determine irrigation requirements.
Wet bulb temperature Temperature, arising from evaporation (humidity temperature). Wet bulb
­temperature is measured at the moisturized thermometer of a psychrometer.
The wet bulb temperature results from the chilling because of the evaporation
at the moisturized thermometer.
3
Humidity
Description
Order No.
Technical Data
1.0400.00.010
Measuring range
Accuracy
Graduation
Aspirator
Measuring time
Psychrometer
Aspiration
Psychrometer
Model Assmann
Portable, handy, sturdy standard instrument for psychrome­
tric humidity measurements.
Used as a control instrument
for humidity measuring instruments. The t­ hermometers
acc. to DIN 58661 can be calibrated. The thermometer capillary has a blue b
­ ack­ground
and a clearly printed scale.
The instrument is equipped
with a moistening device and a
psychrometer-table. Supplied
in a case.
Dimension
Weight
-10 ... +60 °C
±0.2 K (thermometer)
0.2 °C
spring-wound drive
approx. 8 min
(4 ... 2 m/s)
Ø 90 x 420 mm
3.5 kg
ReplacementThermometer
502588
Wick 3.5 mm
502578
Diameter / Length
3.5 mm / 1 m
Suitable for:
- Aspiration
Psychrometer1.0400.00.010
- Replacement
Thermometer502588
Standard Psychrometer
1.0444.10.002
Type of thermometer
Psychrometer
Max.-Thermometer
Min.-Thermometer
Graduation
Total height
Weight
for Aspiration-Psychrometer
1.0400.00.010
Serves as replacement for
used / soiled wicks at
humidity thermometers of
­psychrometers, or as adding,
for upgrading replacement
thermometers to humidity
­thermometers.
Model August
Standard instrument for use in
weather huts and thermometer
huts. The instrument consists
of the following:
2 Psychrometric thermometers
acc. to DIN 58660
1 Maximum thermometer
acc. to DIN 58654
1 Minimum thermometer
acc. to DIN 58653
1 Aspirator with spring-wound
drive
1 Psychrometer table
1 Moistening device as well as
a foot with stand and holder.
Replacement
Thermometer
for Standard Psychrometer
1.0444.10.002
4
Minimum Thermometer
2.0446.00.001
Maximum Thermometer
2.0445.00.002
Standard Thermometer
2.0447.00.002
Measuring range
-30 ... +50 °C ( ±0.2 K)
-30 ... +50 °C ( ±0.2 K)
-40 ... +40 °C ( ±0.3 K)
0.2 °C / 0.5 °C
550 mm
2.6 kg
Humidity
Description
Order No.
Technical Data
Wick 8 mm
502580
Diameter / Length
8 mm / 1 m
Suitable for:
- Standard
Psychrometer1.0444.10.002
Serves as replacement
for used / soiled wicks at
­humidity thermometers of
psychrometers, or as adding,
for upgrading replacement
thermometers to humidity
thermometers.
- Replacement
Thermometer2.0447.00.002
Sling Psychrometer
1.0450.00.010
Measuring range
Accuracy
Graduation
Dimension
Weight
-10 ... +60 °C
±0.2 K
0.2 °C
305 x 60 x 22 mm
0.42 kg
Instrument Case
1.0452.10.000
Colour
Dimension
Weight
black
350 x 230 x 70 mm
0.25 kg
Replacement
Thermometer
502591
Wick 3.5 mm
502578
Simple, sturdy measuring
instrument. The air ventilation
required is attained by rotary
centrifugal movement. The
instrument is supplied with
the required m
­ oistening device
along with a psychrometric
table.
Black synthetic material case,
lined with foam material for
the above instrument including accessories.
for Sling Psychrometer
1.0452.10.000
Serves as replacement for
used / soiled wicks at
humidity thermometers of
­psychrometers, or as adding,
for upgrading replacement
thermometers to humidity
­thermometers.
Diameter / Length
3.5 mm / 1 m
Suitable for:
- Sling Psychrometer 1.0450.00.010
- Replacement
Thermometer502591
5
Humidity
Description
Order No.
Recording Instruments
Hygrograph
1.0610.xx.xxx
Instrument for measurement
and recording of the relative
humidity. Measurement results
are recorded on a strip chart,
which is clamped onto a hand
wound drum clockwork acc. to
DIN 8300 and DIN 58658 or a
quartz clockwork.
Two models are available
regarding the drum clockwork:
1. Mechanical drum clockwork
with hand wound drive for
the temperature range from
-35 … +80 °C (for model
1.0610/614)
Technical Data
1.0614.xx.xxx
1.0615.xx.xxx
.10.
.12.
.000
.900
Recording time
1 day
7 days
14 days
31 days
1 / 7 / 31 days
Thrust
11.45 mm/h,
40 mm/day
20 mm/day,
9 mm/day
s. above
Measuring range
10 ... 100% rel. h.
0 ... 100% rel. h.
Measuring element
H (-35 ... +70 °C)
K (0 ... +80 °C)
non lockable
lockable
Accuracy
Measuring element “H” ±2% rel. h.
+1 scale division
@ 65% rel. h. and
room temperature
Measuring element “K” ±3% rel. h.
+1 scale division
@ 65% rel. h. and
room temperature
82 mm
Recording width
5% rel. h.
Graduation
depending on
Ambient temp.
measuring element
and clockwork
280 x 140 x 214 mm
Dimension
2.2 kg
Weight
2. B
attery-operated quartz
clockwork for the temperature range from -20 …
+60 °C (for model 1.0615…)
Included in delivery:
1 set (100 sheets) strip chats
1 piece felt pen
Accessories
Felt Pen
500847
Colour
violet
Recording Charts
Meas. element H
10 ... 100% rel. h.
Meas. element K
0 ... 100% rel. h.
1 day
7 days
205079
205077
Meas. element H
1 day
7 days
205080 205078
14 days
205082
1 day
14 days
–
1.0598.10.000
Material
Surface
Weight
Varnished aluminium
280 x 140 mm
0.8 kg
(100 pcs.)
Console
To attach the hygrograph
to a wall.
6
31 days
205083
7 days
31 days
–
Humidity
Description
Order No.
Technical Data
1.0509.42.001
Operating range
Accuracy
Type of contact
Control Instruments
Room Hygrostat
The hygrostat serves as twolevel-controller for the regulation of the relative air humidity
in climate test chambers, offices, and computer rooms; it is
suitable for the controlling of
air humidifier or de-humidifier.
Further fields of application
are store rooms, cold storage
rooms, green houses etc.
Duct Hygrostat
The hygrostat serves as twolevel-controller for the regulation of the relative air humidity
in climate ducts and climate
test chambers, it is suitable for
the controlling of air humidifier or de-humidifier. It is used
in store rooms, cold storage
rooms, green houses etc.
Mounting Flange
Serves for mounting the duct
hygrostat 1.0506.60.001.
The flange clamps the
hygrostat to the stem, and
allows, thus, an alternative
mounting variant to the direct
installation of the hygrostat
housing at a duct wall.
Protective Gauze
The protective gauze is placed
on the sensor tube of the duct
hygrostat 1.0509.60.001, and
protects, thus, the measuring
element against coarse dust
particles. Micro switch
Switch difference
Switching capacity
35 ... 95% rel. h.
± 3% rel. h.
1 x change over
(micro switch)
approx. 4% rel. h.
max. 250 V AC and
0.1 … 5 A with
ohmic load for
dehumidification
0.1 … 2 A with
ohmic load for
humidi­f ication
0.1 … 1 A with
inductive load
Operating temperature 0 ... +60 °C
Housing
Plastic, grey
Protection
IP 20
Dimension
115 x 70 x 42 mm
Weight
approx. 0,12 kg
1.0509.60.001
Operating range
Accuracy
Type of contact
Micro switch
Switch difference
Switch capacity
with ohmic load
Switch capacity
with inductive load
Switch capacity
with D/C voltage
Max. voltage
Switch capacity,
minimum load
Operating temperature
Housing
Protection
Dimension
Housing
Stem length
Weight
1.0509.81.000
500278
35 ... 95% rel. h.
±4% rel. h.
1 x switch over
(micro switch)
approx. 4% rel. h.
15 A @ 230 V
2 A @ 230 V
0.25 A DC @ 230 V
250 V AC
100 mA, 125 V AC
0 ... +60 °C
Plastic, light grey
IP 64
80 x 120 x 72 mm
L 220 mm, Ø 16 mm
approx. 0.7 kg
Material
Diameter for
immersion tube
Total diameter
Weight
Aluminum
approx. 19 mm
Length
Diameter
inside
outside
Material
Width of mesh
Weight
200 mm
50 mm
0.025 kg
approx. 16 mm
approx. 16.8 mm
Stainless steel
0.32 mm
0.011 kg
7
Humidity
Description
Order No.
Technical Data
Wind screen
1.0509.85.002
Length
Diameter
inside
outside
Material
Width of mesh
Weight
200 mm
Electr. output
200  linear
200  linear
Connecting
Lemosa plug
3 m cable
Measuring range
Accuracy
Ambient temp.
Scale graduation
Measuring element
Scale length
Stem
Stem length
Protection
Total length
Weight
10 ... 100% rel. h.
±2% rel. h.
@ 20 ... 100% rel. h.
and room
temperature
-35 ... +70 °C
1% rel. h., non-linear
H
94 mm (90°)
Ø 22 mm
250 mm
IP 65, case
350 mm
0.7 kg resp. 0.9 kg
Consisting of and dust shield.
Both are placed on the ­sensor
tube of the duct hygrostat
1.0509.60.001 and, thus,
are protecting the measuring
­element against coarse dust
particle, and faulty measurements with airflows > 3 m/s.
approx. 16 mm
approx. 19 mm
Stainless steel, MS
0.32 mm
0.043 kg
Electrical Transmitters
Hygro-Transmitter
Measures and indicates
­humidity. Equipped with
­electrical output for longrange transmission. Sturdy
­construction. The ex­posed
parts such as the case head
and the immersion stem are
made of stainless steel.
Wind Protection
1.0509.85.006
Diameter
Length
Mesh aperture
Material
Weight
24 mm
200 mm
0.32 mm
Niro, Brass
0.05 kg
Weather and Thermal
Radiation Shield
1.1025.51.000
Installation pin
Material
Ø 22 x 27 mm
Al, galvanised and
varnished
Ø 170 x 450 mm
2.2 kg
Gauze- and wind protection p
­ rotects the humidity
­measuring element from
coarse dust (> 0.32 mm) and
error measurements in case
of wind velocities > 3 m/s.
Suitable for above hygro
­transmitter.
Protective covering for the
­preceding hygro-transmitters
for outdoor installation. Helps
to prevent atmospheric influences and radiation errors
from influencing the measured
results.
8
1.1000.50.xxx
.015
.515
Dimension
Weight
Humidity
Description
Order No.
Technical Data
Psychrogeber
1.1130.xx.000
.20.
Operating voltage
Measuring instrument to
determine the air humidity values based on the dry
and moist temperature An
attached water container provides for the moistening of the
psychro sensor. The doublewalled protection tubes protect the sensor from radiation.
.22.
Operating voltage
Measuring range
Measuring elements
Accuracy
Time constante
Airflow
Water container
Type of switching
Connection
A hanger, included in delivery,
serves for the lateral mounting
of the psychro-transmitter at a
facade, wall etc.
Dimension
Psychro transmitter
Hanger
Weight
Psychro transmitter
Hanger
Replacement-Sensor
2.1266.10.001
Soil Moisture Probe
Trime-Pico 32, serial
1.0231.00.000
for Psychro-Transmitter
1.1130… compl., consisting of
Pt 1000 (1/3 class B) casing and
plug ­connection
Soil moisture sensor with
­integrated temperature
­sensor.
The network-compatible
instrument serves for the
measurement of volumetric
water content in the ground
and the soil temperature.
The data communication
is carried out via an RS485
­interface.
It is used with
• Hydrology,
• Forestry,
• Agriculture,
• Environmental- and
Geological science
Humidity
measuring range
Accuracy
Temperature
­measuring range
Accuracy
Operating voltage
Power consumption
Electr. output
Connection
Protection
Dimension
Probe
Rod
Weight
12 V AC / 6 W
24 V AC / 11 W
24 V DC / 8 W
12 V DC
0 ... +60 °C
2 x Pt 100, acc. to
DIN IEC 60751
1/3 class B (±0.1 K)
17 s (90%)
4 ... 6 m/s
250 ml
4-wire circuit
2 x 4 pole plug
connection
Ø: 160 mm,
H: 465 mm
L: 310 mm
3.7 kg
1.0 kg
0 ... 100% volumetric
water content
±2% @ 0 ... 40%
±3% @ 40 ... 70%
-15 ... +50 °C
±1.5 °C
7 ... 24 V DC
100 mA @ 12V/DC
during 2 ... 3 sec of
measurement
RS485
5 m cable with
­cable-end sleeves
IP 68
Ø 32 x 155 mm
Ø 3.5 x 110 mm
approx. 0.12 kg
The electrical connection is
carried out via a permanently
connected cable.
9
Humidity
Description
Order No.
Technical Data
Soil Moisture Probe
Trime-Pico 32, analogue
1.0231.00.060
Humidity
measuring range
Accuracy
Instrument as above, however,
the measuring value output
occurs as analogue signal.
Temperature
measuring range
Accuracy
Operating voltage
Power consumption
Electr. output
Connection
Protection
Dimension
Probe
Pod
Weight
10
0 ... 100% volumetric
water content
±2% @ 0 ... 40%
±3% @ 40 ... 70%
-40 ... +70 °C
±1.5 °C
7 ... 24 V DC
100 mA @ 12V/DC
during 2 ... 3 sec of
measurement
2 x 0 ... 1V
5 m cable with
­cable-end sleeves
IP 68
Ø 32 x 155 mm
Ø 3.5 x 110 mm
Approx. 0.12 kg
Temperature measurements are
fundamentally important in the ­
different fields of science, industry
and environmental technique.
The legal requirements e.g. for the
­storing of food, get constantly s­ tricter,
and meanwhile lay down also ­official
controls of climatic data.
Our instruments with calibration
­certi-ficate meet these requirements.
Reliable measurements and docu­mentation of extreme temperature ranges
and temperature fluctuations as well
as ­­high-precise measurements are
problem-free possible with the different instrument components. Exactly
acquired and ­recorded temperature
­values form the basis for effective
energy optimising and energy saving.
Meteorological garden with weather huts
Meteorological data for
the road condition
Climatic measurement of the South Pole
12
Temperature
Glossary
Bimetallic measuring element A strip composed of two different metals which are welded together.
The two different heat expansion coefficients of these metals lead to
a temperature-dependent curvature of the welded metal. This curvature
respectively deflection is a measure of the upcoming temperature
Extreme Thermometer Combination of a min.- and a max. -thermometer to measure the current,
the lowest and the highest temperature of the preceding measurement period.
Max.-Thermometer For the measurement of the current and highest temperature of the preceding measurement period.
A pin is pushed forward through the meniscus of the mercury filament by
raising temperature, and remains with the maximum temperature value
when the temperature drops.
The thermometer is used in horizontal position
Min.-Thermometer For the measurement of the current and lowest temperature of the preceding measurement period.
A pin in the alcohol filament is pushed back by the surface tension of the
alcohol, and remains with the minimum temperature value when the
temperature increases.
Perceived Temperature The ambient temperature as perceived by the human body affected by the wind. It is calculated from the “wind-chill” factor.
Pt 100 Sensor
Is a temperature sensor with a measurement coil made of platinum wire.
The temperature-dependent resistance-change of the platinum wire is used
as measure for the temperature.100 Ω for 0 °C is used as basic value. The resistance-change is defined in the DIN IEC 60751 standard.
Soil Surface Thermometer Measurement instrument to measure the temperature above the soil, preferably at a height of 5 cm. The German Weather Service uses sensors without radiation protection only to measure the minimum temperature.
Soil Thermometer Measurement instrument to measure the air temperature in soil at different depths.
Temperatur transmitter Thermograph Thermometer Electrical temperature measurement instrument with an electrical measured value output.
Measurement instrument which mechanically records the temperature
as a function of time
General term for a temperature measurement instrument
Units
Kelvin [K] Celsius [°C] Fahrenheit [°F] Used since 1976 as the legal unit of temperature.
It starts at -273.15 °C
Common temperature degree scale in which the melting
point of ice is 0 °C and the boiling point of water is 100 °C
on a thermometer at an air pressure of 1013.2 mbar.
Temperature scale frequently used in Anglo-Saxon countries.
On this scale, the melting point of ice is 32 °F
Conversions°C = K -273.15 K
°C = 5
– (°F - 32)
9
Windchill
K = °C +273.15 °C
9 °C
°F = 32 + –
5
The loss of heat by the human body [W/m2] through the wind
The “perceived temperature” is derived from this factor.
13
Temperature
Description
Order No.
Technical Data
2.0445.00.002
.010
.011
.017
Measuring range
-30 ... +50 °C
-10 ... +60 °C
-10 ... +50 °C
0 ... +60 °C
Graduation/Accuracy
0.5 °C / ±0.2 K
0.5 °C / ±0.5 K
0.2 °C / ±0.2 K
0.2 °C / ±0.2 K
Dimension
Weight
Ø 19 x 300 mm
0.075 kg
Measuring range
-40 ... +40 °C
-40 ... +40 °C
-30 ... +50 °C
-45 ... +40 °C
-40 ... +60 °C
Graduation/Accuracy
0.5 °C / ±0.2 K
0.2 °C / ±0.2 K
0.2 °C / ±0.2 K
0.2 °C / ±0.2 K
0.5 °C / ±0.5 K
Dimension
Weight
Ø 19 x 300 mm
0.06 kg
Measuring range
-30 ... +50 °C
-10 ... +50 °C
-30 ... +60 °C
Graduation/Accuracy
0.2 °C / ±0.2 K
0.2 °C / ±0.2 K
0.2 °C / ±0.2 K
Liquid
Dimension
Weight
Alcohol or mercury
Ø 16 x 370 mm
0.06 kg
Measuring range
-25 ... +60 °C
-25 ... +60 °C
-25 ... +45 °C
-22 ... +40 °C
-15 ... +40 °C
-15 ... +35 °C
-15 ... +35 °C
Immersion depth
20 mm
30 mm
60 mm
110 mm
160 mm
210 mm
310 mm
Accuracy
±0.4 K (< 0 °C)
±0.2 K (0 ... 50 °C)
±0.3 K (> +50 °C)
0.2 °C
150°
approx. 0.95 kg
Thermometers
Maximum-Thermometer
A mercury glass thermometer,
can be calibrated. Employed
to determine the highest air
temperature.
Minimum-Thermometer
An alcohol glass thermometer,
can be calibrated. Employed
to determine the lowest air
temperature.
Standard-Thermometer
A mercury glass thermometer,
can be calibrated. Designed
for measuring the current
ambient temperature. Also
used as
a spare thermometer for
psychrometers model August.
2.0446.00.001
.002
.066
.067
.092
2.0447.00.002
.011
.056
Soil Thermometer
A mercury glass ­thermometer, 2.2110.02.003
.03.003
can be calibrated. D
­ esigned
.06.004
for measuring the soil
.11.006
­temperature. Supplied with
.16.008
a holder. The immersion
.21.009
depth governs the depth of
.31.009
the measuring point in the soil.
Graduation
Bending
Weight
Soil Depth Thermometer
Consists of a mercury glass
­thermometer with a holder
and a plastic guide tube.
The immersion depth governs
the depth of the measuring
point in the soil.
14
2.2115.03.013
2.2116.03.013
Immersion depth
Measuring range
Accuracy
Graduation
Guide tube
Weight
500 mm
1000 mm
-10 ... +30 °C
±0.3 K (-10 ... -5 °C)
±0.15 K (-5 ... -30 °C)
0.1 °C
Ø 40 mm
0.9 kg resp. 1.4 kg
Temperature
Description
Order No.
Technical Data
Extreme Thermometer
for use in soil
2.2121.xx.002
2.2122.xx.002
.02.
.05.
.10.
.20.
Type
Consists of a mercury glass
thermometer with a bent
immersion stem, d
­ etermines
the lowest and highest
­temperature of the soil.
The immersion depth governs
the depth of the measuring
point in the soil.
Immersion length
Min.-Thermometer
Max.-Thermometer
20 mm
50 mm
100 mm
200 mm
Measuring range
Accuracy
Graduation
Bending
Weight
-25 ... +50 °C
±0.4 K / ±0.3 K
0.2 °C
95°
0.12 kg
Thermometer Stand
2.2123.00.000
Material
Dimension
Weight
Stainless steel
340 x 320 x 20 mm
0.7 kg
Extreme Thermometer
2.2135.00.000
Techn. data
Total height
Weight
see instrument no.:
2.0445.00.002 and
2.0446.00.001
(page 14)
320 mm
1.5 kg
Measuring range
Graduation
Fluid
Material of case
Length of scale
Dimension
Weight
-38 ... +50 °C
1 °C
Mercury
white synthetic
110 mm
220 x 66 x 35 mm
0.17 kg
not depicted
Holds the extreme
­thermometer for use in soil,
described in the preceding.
Determines the lowest and
high­est ambient temperature.
Consists of a maximum
­thermometer and a minimum
thermometer with stand.
Max.- and Min.Thermometer
2.2004.00.079
Thermometer determines the
current temperature as well
as the lowest and the highest
temperatures of the measuring
­period.
There is an adjustment
knob to set back the marker
threads for extreme value
­identification.
■o
ther thermometer-variants,
measuring range and scales on request
15
Temperature
Description
Order No.
Technical Data
Water Thermometer
2.2141.00.064
Measuring range
Accuray
Graduation
Fluid
Container
Dimension
Weight
-5 ... +40 °C
±0.2 K
0.5 °C
Mercury
Brass, nickel plated
Ø 28 x 300 mm
0.4 kg
2.0605.10.xxx
Recording time
1 day
7 days
14 days
31 days
1 / 7 / 31 days
Thrust
11.45 mm/h,
40 mm/day
20 mm/day
9 mm/day
see preceding
.0xx
.9xx
non-lockable
lockable
.x00
.x05
.x11
.x14
.x17
Measuring range
-35 ... +45 °C
-20 ... +60 °C
-10 ... +50 °C
0 ... +40 °C
0 ... +80 °C
Graduation
1 °C
1 °C
1 °C
0.5 °C
1 °C
Accuracy
±1% of mr.
+1 scale division
@ 65% r.h and
room temperature
Measuring element
Recording width
Dimension
Weight
Bimetal
82 mm
280 x 138 x 214 mm
2.2 kg
1.0598.10.000
Material
Surface
Weight
Aluminium, varnished
280 x 140 mm
0.8 kg
Felt Pen
500847
Colour
violet
Recording Charts
temp. range
-35 ... +45 °C
-20 ... +60 °C
-10 ... +50 °C
0 ... +40 °C
0 ... +80 °C
1 day
7 days
14 days
205060 205046 205063
205050 205036
205052205038
205054 205040 205064
205057
205043
Thermometer determines the
water temperature.
A glass mercury thermometer
in a metal tube with a large
perfo­rated water container.
Recording Instruments
Thermograph
Instrument for measurement
and recording of the ambient
temperature. Measurement
results are recorded on a strip
chart, which is clamped onto
a hand wound drum clockwork
acc. to DIN 8300 and
DIN 58658 or a quartz
clockwork.
Two models are available
regarding the drum clockwork:
1. M
echanical drum clockwork
with hand wound drive for
the temperature range from
-35 … +80 °C
(for model 2.0600/604…)
2.0600.10.xxx
2.0604.10.xxx
2. Battery-operated quartzclockwork for the temperature range form -20 … +60 °C
(for model 2.0605…).
Included in delivery:
1 set (100 sheets) strip chats
1 piece felt pen
Console
Instrument for wall mounting
of the thermograph described
in the preceding.
Accessories
(100 pcs.)
For Thermograph
16
31 days
205069
205075
205068
205076
Temperature
Description
Order No.
Technical Data
Electrical Transmitters
Temperature Transmitter 2.1235.00.xxx
2.1235.01.xxx
Water Temperature
.000
Transmitter
The measuring element is
protected by a waterproof and
stainless steel tube, it has a
PVC cable resp. a FEP-cable.
.010
.020
Measuring range
Cable length
Measuring element
Accuracy
Electr. connection
Cable
Sensor dimension
Weight
Soil Surface Temperature
Transmitter
2.1241.00.000
Instrument measures the
temper­ature above the surface
of the soil. The temperature
sensor is protected by a
­­well-ventilated double-walled
tube with roofing plate.
Measuring range
Measuring element
Accuracy
Electr. connection
Cable
Protective shield
Dimension
Weight
2.1260.00.000
Air Temperature
Transmitter with Thermal
Radiation Shield
The instrument is designed
to measure the temperature
­outdoor precisely. It has a
specially constructed wellventilated thermal radiation
shield made of an anodized
aluminium.
Ventilated Air
Temperature Transmitter
This instrument is designed
to measure the precise air
­temperature with the air of a
ventilated sensor. The sensor
is protected by a double
­thermal radiation shield. A
built-in ­ventilator pro­vides
for the necessary air flow.
A hanger, included in delivery,
serves for the lateral mounting
of the air temperature transmitter at a facade, wall etc.
Replacement-Sensor
for Ventilated Air Temperature
Transmitter 2.1265… compl.
consisting of PT 100 (1/3 Class B),
casing and plug connection
2.1265.xx.000
.20.
.22.
Measuring range
Measuring element
Accuracy
Electr. connection
Connection
Dimension
Weight
Operating voltage
Operating voltage
Measuring element
-30 ... +100 °C (±0.1 K)
-50 ... +200 °C (±0.1 K)
5m
10 m
20 m
Pt 100
acc. to DIN IEC 60751
1/3 class B
(0.1 °C at 0 °C)
4-lead circuit
LIYCY 4 x 0.25 mm2
Ø 6 x 70 mm
0.3 kg; 0.6 kg; 1.2 kg
-30 ... +50 °C
Pt 100
acc. to DIN IEC 60751
±0.1 K; 1/3 class B
4-lead circuit
5 m, LiYCY
4 x 0.25 mm2
double tube,
varnished
Ø 177 x 100 mm
1 kg
-30 ... +50 °C
Pt 100
acc. to DIN IEC 60751
±0.1 K; 1/3 class B
4-lead circuit
4-pole clamp
Ø 120 x 400 mm
0.8 kg
12 V AC/ 6 W or
24 V AC/ 11 W or
24 V DC/ 8 W
12 V DC/ 4 W
Pt 100
acc. to DIN IEC 60751
1/3 class B (±0.1 k)
17 s (90%)
4 ... 6 m/s
4-wire circuit
4 pole plug connection
Accuracy
Time constant
Air flow
Type of switching
Connection
Dimension
Air temp. transmitter Ø: 160 mm,
H: 465 mm
Hanger
L: 310 mm
Weight
Air temp. transmitter 3.5 kg
Hanger
1.0 kg
2.1266.10.001
17
Temperature
Description
Order No.
Technical Data
Temperature Sensor
compact
2.1280.00.xxx
.000
Electr. output
Pt 100 acc. to
DIN IEC 60751
4 ... 20 mA
0…1V
0 ... 10 V
0…5V
Accuracy
class B
(±0.1 K)
±0.3 K
±0.2 K
±0.2 K
±0.2 K
Measuring range
Time constant
Ambient temp.
Operating voltage
I-output
U-output (10 V)
U-output 5 V)
U-output (1 V)
Int. power consump.
Cable
Dimension
Weight
-30 ... +70 °C
20 s (90%)
-40 ... +80 °C
Electr Output
Pt 100 acc. to
DIN IEC 60751
0 ... 10 V
Connection
Dimension
Weight
Accuracy
1/3 Class B (±0.1 K)
Clamping range
Wall distance
Ø 20 mm
83 mm
(to transmitter centre)
plastic, grey flange
plate with 3 x 6.5 mm
boring
96 mm long
0.075 kg
Electrical measured value
receiver to measure the
ambient temperature, The
measured value is emitted as
a resistance value in accordance with DIN IEC 60751 resp.
as an analogue voltage or current signal.
Temperature Sensor
compact
• Plug type
Model like 2.1280.00.1xx,
however with plug and mating
connector instead of von permanently connected cable.
Teflonfilter with gauze ZE 20
This hood is placed over
the sensor and protects the
measurement element from
coarse dirt.
Sinter Filter ZE 21
.141
.160
.161
.173
2.1280.00.xxx
.700
.761
1.1005.54.902
Wall Holder
1.1005.54.903
Material
Mounting
Dimension
Weight
Weather and Thermal
Radiation Shield, compact
Protective case for the prece­
ding temperature sensor compact for outdoor installation.
This case essentially eliminates
the influence of weather and
radiation errors which affect
the measurement result.
18
12-30 V DC
15-30 V DC
10-30 V DC
6-30 V DC
approx. 5 mA (10V)
5 m long
Ø 20 x 138 mm
0.35 kg
±0.2 K
connector
Ø 20 x 155 mm
approx. 0.4 kg
1.1005.54.901
made of metal. This basket is
placed over the sensor and protects the measurement element
from high wind speed ­(> 5 m/s)
and increased dust.
A ne­ces­sity for sensors in use
in e­ x­po­sed areas, eg. in marine
climates, desert, mountains.
- for mounting the Temperature
­Sensor 2.1280 onto a wall,
- r adiation- and precipitationprotected use (for ex. indoor)
1/3
1.1025.55.00x
.10x
.xx0
.xx1
Without ventilator
With ventilator
Clamping
Material
Mounting
Cable
Dimension
Weight
12 V DC; 2.5 W
Ø 35 … 50 mm
Ø 55 … 60 mm
syn. laminations,
white
non-corroding holder
5 m, for model ... 10x
Ø 120 x 275/290 mm
0.8 kg
Remark: For the putting into circulation of mercurial thermometers, see guideline 2007/51/EG
of the European Parliament and Council and regulation (EG) No. 847/2012.
The acquisition and recording of
air pressure differences and areas
of low and high pressure are the
main tasks of the meteorology for
precise weather forecasting. But
also in the field of laboratorial
and environmental technique the
exact determination of air ­pressure
is very important. The THIES
­instruments configuration with
their varied forms of calculation
and representation guarantee
a high precision measurement
­according to requirements.
20
Air Pressure
Glossary
Air pressure (P)The air pressure of any place in the earth’s atmosphere is the pressure of
the air, existing at this place. It indicates the weight power of the air column
standing above a surface or body.
Barograph
is a measuring instrument which records the time course of the air pressure
on a chart-stringed drum.
Barometeris a measuring instrument for determination (display) of air p
­ ressure, and
is used in a variety of different forms and types mostly in the field of
meteorology.
Barometric Altitude Formula indicates the vertical change of the air pressure with the altitude.
Simplify you may assume that close to the sea level the air pressure declines
by one hPa per 8 m altitude.
Barometric Unit
Unit of the air pressure is the Pascal.
As the air pressure on sea level is, on average, 101325 Pa, thus approx.
100000 Pa, it is given mostly by the number about 1000 in hectopascal
(1013.25 hPa) or by the same numerical value millibar (mbar). The air pressure
is mostly measured through a barometer, where often obsolete units are used.
Here is: 1 hPa = 1 mar = 0.75 Torr (= mm Hg or millimeter mercury column).
Baro transmitter
is a measuring instrument with electrical measuring value output
QFEQFE means the air pressure of aerodrome/airport on the runway. If QFE is set
at the altimeter (for ex. before start or landing) you achieve the barometric air
pressure or height related to the airport height. On the airport the altimeter
­indicates then a height of 0 m or 0 ft.
QFF
QFF is the current air pressure at the measuring site (for ex. aerodrome/­airport),
reduced to the sea level. It is used in the field of meteorology in order to
­compare the air pressures of different places at different heights.
The c­ alculation is carried out with ASL (altitude above sea level) and data of
the “current atmosphere” (pressure, temperature, and humidity).
QNHThe abbreviation QNH means the air pressure at the measuring station,
reduced to sea level acc. to “standard atmosphere”.
It serves for setting an altimeter which displays the flight altitude above sea
level. After landing of the aircraft, the altimeter displays the altitude of site ­above sea level.
Standard atmosphere
is a term used in aviation. Characteristics like pressure, temperature, or
temperature course with the altitude are subject to special and time changes
in the atmosphere. The standard atmosphere indicates an average state of
the atmosphere.
TA
Transition Altitude is a term used in aviation. It indicates the altitude where
the transition of the altimeter setting from standard air pressure to the currently
existing air pressure QNH is carried out or vice versa.
TLTransition Level (TL) is the lowest flight level available for use which has a
­minimum distance of 1000 ft above the transition altitude. Therefore the
­Transition Level is depending on the air pressure. In some regions of Germany
the Transition Altitude is, generally, 5000 ft.
21
Pressure
Description
Order No.
Technical Data
3.1503.00.010
Measuring range
Aneroid Barometers
Barometer
Indicating instrument for the
barometric pressure.
Scale with brass ring, housing
made of mahogany.
Barometer
Indicating instrument
with a mounting flange for
wall mounting. Light grey
­varnished.
Scaling
Measuring system
Dimension
Scale
Housing
3.1509.00.000
Measuring range
Graduation
Accuracy
Above sea level
Measuring element
Scale
Dimension
Weight
965 ... 1055 hPa
730 ... 790 Torr
10 hPa, 1 Torr
Aneroid capsule
Ø 130 mm
Ø 170 mm
935 ... 1065 hPa
700 ... 800 Torr
1 hPa; 1 Torr
±3 hPa at
980-1030 hPa
0-1000 m
Aneroid capsule
Ø 100 mm
Ø 120 x 45 mm
0.3 kg
Mercury Barometers
Mercury
Station Barometer
An instrument designed to
­measure and test atmospheric
air pressure in meteorological
stations, laboratories etc. The
instrument is equipped with
an additional thermometer.
3.1550.17.000
.001
Measuring range
800 ... 1080 hPa
560 ... 1030 hPa
Graduation
Accuracy
Temp. meas. range
Dimension
Weight
0.1 hPa, vernier scale
±0.3 hPa
-15 ... +50 °C
Ø 65 x 940 mm
4.8 kg
For measuring range
800 ... 1080 hPa
560 ... 1030 hPa
1000 x 115 x 13 mm
2 kg
Delivery in a wooden transport
box
Mounting Board
For vertical installation of the
mercury station barometer.
22
3.1552.00.000
.001
Dimension
Weight
Pressure
Description
Order No.
Recording Instruments
Barograph
The instrument serves for the 3.0800.10.xxx
measurement and recording of
3.0804.10.xxx
the barometric air pressure.
The recording is carried out
3.0805.10.xxx
on a strip chart which is
clamped onto a hand wound
.000
drum clockwork acc. to DIN
.900
8300 and DIN 58658 or onto a
quartz clockwork.
The local altitude can be set
by means of an adjusting
screw.
As to the drum clockwork two
models are available:
Technical Data
Recording time
1 day
7 days
14 days
31 days
1 / 7 / 31 days
non lockable
lockable
Measuring range
Graduation
Accuracy
1. M
echanical drum clockwork
with hand wound drive (for
model 3.800../3.0804..)
Above sea level
Measuring element
2. Battery-operated quartz
clockwork (for model
3.805..)
Ambient temp.
Recording width
Dimension
Weight
Included in delivery:
1 set (100 sheets) strip chats
1 piece felt pen
Micro Barograph
Recording precision measuring
instrument for the measurement of the atmospheric air
pressure.
The local elevation is set
at the measurement site by
means of an adjusting screw.
The recording is carried out on
a strip chart which is clamped
onto a hand wound drum
clockwork acc. to DIN 8300
and
DIN 58658.
3.0810.20.000
Accessories
Felt Pen
Recording time
Thrust
945 ... 1052 hPa
1 hPa
±0.8 hPa
+1 scale division
@ 65% rel. h. and
room temperature
0 ... 3000 m
Aneroid-capsules
temperature
compensated
-10 ... +45 °C
82 mm
280 x 138 x 214 mm
2.3 kg
Ambient temp.
Dimension
Weight
1 / 7 days, switchable
11.45 mm/h or
40 mm/d
965 ... 1050 hPa
±0.3 hPa
+1 scale division
@ 65% rel. h. and
room temperature
160 mm
1 hPa
0 ... 2000 m,
adjustable
2 Aneroid capsules,
temperature
compensated
-10 ... +45 °C
280 x 138 x 285 mm
3 kg
Colour
violet
Measuring range
Accuracy
Recording width
Graduation
Above sea level
Measuring element
Included in delivery:
1 set (100 sheets) strip chats
1 piece felt pen
Thrust
11.45 mm/h
40 mm/d
20 mm/d
9 mm/d
see preceding
500847
Recording Charts
Meas. range
945 ... 1052 hPa
1 day
205184
7 days
205182
14 days
205185
31 days
205186
Recording Charts
Meas. range
965 ... 1050 hPa
1 day
205188
7 days
205187
14 days
–
31 days
–
(100 pcs.)
for Barograph
3.080x.10.xxx
(100 pcs.)
for Micro Barograph
3.0810.20.000
23
Pressure
Description
Order No.
Technical Data
Electrical Transmitter
Baro Transmitter
• Scalable
- measuring range
- Analogue output
• Configurable
- mean value calculation
- heating control,
- energy saving mode,
- baud rate
The baro transmitter measures
the “absolute air pressure” of
the atmosphere at the site. It
is designed for application in
the field of environmental protection, where high accuracy,
quick responding behaviour,
long-term stability and reliability are required.
The instrument is suited for
in- and outdoor application.
A tempered piezo-ceramic
sensor for absolute pressure
is used, which is characterized
by thermal and mechanical
stability.
The electric connection is done
via an 8-pole terminal strip
and a special screwed cable
gland with smoothing function
for air pressure.
3.1157.10.000
3.1157.10.040
3.1157.10.041
3.1157.10.061
3.1157.10.140
3.1157.10.141
3.1157.10.161
Measuring range
(factory settings)
300 ... 1100 hPa
300 ... 1100 hPa
800 ... 1060 hPa
300 ... 1100 hPa
300 ... 1100 hPa
600 ... 1060 hPa
300 ... 1100 hPa
300 ... 1100 hPa
600 ... 1060 hPa
300 ... 1100 hPa
300 ... 1100 hPa
600 ... 1060 hPa
300 ... 1100 hPa
300 ... 1100 hPa
800 ... 1060 hPa
300 ... 1100 hPa
300 ... 1100 hPa
800 ... 1060 hPa
300 ... 1100 hPa
300 ... 1100 hPa
800 ... 1060 hPa
Accuracy w/o heating
±1 hPa
@ -20 ... +65 °C
Long-term stability
Current consumption
(@12VDC)
W/o heating
With heating
Ambient temperature
Dimension
Weight
24
±0.1 hPa/year
5/8/12 ... 24 V DC
Operating voltage
depending on mode of
operation and model
Connection
Baro transmitters measure the
barometric ambient pressure
and emit the measured value
as an electrical voltage value.
Owing to its low current
­consumption, It is particularly
suitable for use in combination
with data loggers.
To be mounted preferably in
data logger systems.
1 x RS485
1x 300 ... 1100Hz
1 x 0 ... 5 V
1 x RS485
1 x 300 ... 1100 Hz
1 x 0 ... 20 mA
1 x RS485
1 x 300 ... 1100 Hz
1 x 4 ... 20 mA
1 x RS485
1 x 300 ... 1100 Hz
1 x 0 ... 10 V
1 x RS485
1 x 300 ... 1100 Hz
1 x 0 ... 20 mA
1 x RS485
1 x 300 ... 1100 Hz
1 x 4 ... 20 mA
1 x RS485
1 x 300 ... 1100 Hz
1 x 0 ... 10 V
Accuracy with heating
±0,25 hPa
@ -40 ... +65 °C
The following outputs are
available:
1 x serial interface
1 x frequency output
1 x analogue output (U/I)
Baro Transmitter
B-278-1T
Baro Transmitter
B-278-2T
Electr. output
3.1158.00.075
3.1158.10.075
Measuring range
B- 278-1T
Accuracy @ 20 °C
Linearity
Hysteresis
10 mA (max.)
115 mA (max.)
Screwed cable gland
and terminal strip
-40 ... +65 °C
approx.
110 x 82 x 57 mm
0.15 kg
800 ... 1060 hPa
600 ... 1060 hPa
±0.30 hPa
±0.25 hPa
±0.03 hPa
S- 278-2T
Accuracy @ 20 °C
Linearity
Hysteresis
±0.50 hPa
±0.45 hPa
±0.05 hPa
Resolution
Long term stabilty
Electr. output
Operating voltage
Ambient temp.
Dimension
Weight
0.01 hPa
0.1 hPa / Yr
0 ... 5 V DC
9.5-28 VDC (3 mA)
-40 ... +60 °C
61 x 91 x 25 mm
0.14 kg
Pressure
Description
Order No.
Technical Data
Digital Baro Transmitter
3.1159.00.xxx
.040
.041
Electr. output
Indicating measuring instrument with analogue output
to de­termine the atmospheric
­pressure. An aneroid capsule
with inductive displacement
pickup serves as a sensor. The
sensor signal is amplified ­
el­ectronically and ­displayed
on a LC display. The a
­ nalogue
output is available for the
­connec­tion of ­electronic
­recording and control
­instruments. Behind the
front panel is a potentiometer
to ­reduce the mea­sured value
to sea level. The in­strument
is in the form of a switch cabinet
for panel installation.
Baro Display
Displaying measuring instrument for four air pressure
parameters. Instrument with
integrated pressure sensor.
Analogue output and serial
interface serve for output of
measuring data to processing
systems.
Display parameter:
• QNH air pressure relating to
the sea level with standard
atmosphere
• QFE air pressure related to
the runway
• P absolute pressure
• TL Transition-Level
• Tendency
Measuring value output:
• The output of the
displayed parameters is
carried out via a serial
interface. The interface
specifications are settable.
• The analogue output of
absolute pressure P is
done via an integrated
analogue-interface
(U/I is settable).
Load
Measuring range
Accuracy
Resolution
Display
Temp. range
Above sea level
Operating voltage
Model
Dimension
Weight
3.1156.xx.000
.00
0 ... 20 mA
4 ... 20 mA
 250 
913.3 ... 1113.3 hPa
±0.5 hPa (at NN)
0.1 hPa
4 1/2-digit LED red
0 ... +50 °C
0 ... 850 m
230 V AC or 115 V AC
or 12 ... 28 V DC
panel mounting
96 x 96 x 127 mm
0.6 kg
Operating voltage
230 V / 50Hz; 24 V AC
12-35 V DC
115 V / 50 Hz; 24 V AC
12-35 V DC
Measuring range
Accuracy
Resolution
Digital interface
Type
Baud rate
600 ... 1100 hPa
±0.25 hPa
0.1 hPa
.01
Parameter
1 x RS 422
1200, 2400, 4800,
9600, 19200, 57600
for ex. 8N1, 7E1
Analogue output
1 x 0 ... 5 V or
1 x 0 ... 10 V or
1 x 0(4) ... 20 mA
Accuracy
±0.3% of the end of
measuring range
@Tamb +20 °C
Display
4 x 5-digit, LED red,
14 mm high
Temperature range
Construction
Dimension
Protection
Weight
-10 … +50 °C
switch panel mounting
144 x 144 x 135 mm
IP 20
1.5 kg
Operation:
through front side key button
• Dimming display,
storing brightness,
setting baud rate,
setting protocol format,
function test
• Editing parameter to QNH,
QFE, offset correction for
absolute pressure P
25
Pressure
Description
Order No.
Technical Data
Baro Display
3.1156.xx.001
.00
Operating voltage
230 V / 50 Hz; 24 V AC
12-35 V DC
115 V / 50 Hz; 24 V AC
12-35 V DC
Measuring range
Accuracy
Resolution
600 ... 1100 hPa
±0,25 hPa
0.1 hPa
Displaying measuring instrument for four air pressure
parameters with integrated
pressure sensor.
Analogue output and serial
interface serve for the output
of the measuring data to systems for further processing.
Display parameter:
• QFF*, - air pressure reduced
to sea level at measuring site
• QFE air pressure referred to
runway
• Rel. humidity
(0 ...100% rel. h.)
• Temperature (-40 ... +70 °C)
Measuring value output:
• The output of the displayed
parameters is carried out via
a serial interface. The interface specifications are settable.
• The analogue output of
absolute pressure P is done
via an integrated analogue
interface (U/I is settable)
Operation:
through front side key button
• Dimming display,
storing brightness,
setting baud rate,
setting protocol format,
function test
• Editing parameter to QFF,
QFE, offset correction for
absolute pressure P
.01
Digital interface
Type
Baud rate
Parameter
Analogue output
Accuracy
Analogue input
for rel. humidity
for temperature
1 x 0 ... 5 V or
1 x 0 ... 10 V or
0(4) ... 20 mA
(= 600 ... 1100 hPa)
±0.3% of measuring
range @Tamb +20 °C
0-1V(2V, 5V, 10V) or
0(4) ... 20mA
Pt100
Display
4 x 5-digit, LED red,
14 mm high
Temperature range
Construction
Dimension
Protection
Weight
-10 … 50 °C
Panel mounting
144 x 144 x 135 mm
IP 20
1.5 kg
* display
and output is possible only with connection of
a suited Hygro-thermo transmitter (for ex.1.1005.54.000).
Remark
For the putting into circulation of mercury barometers, see
guideline 2007/51/EG of the European Parliament and Council
and regulation (EG) Nr. 847/2012.
26
1 x RS 422
1200, 2400, 4800,
9600, 19200, 57600
for ex. 8N1, 7E1
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
1.0165.42.058
1.0169.42.058
Model
Indicators
Hygro-Thermometer
Combined indicating instrument designed to measure
the ambient ­temperature and
rel. humidity, as well as the
­representation of the normal
climate acc. to DIN 50014,
and of a comfort range
Recording Instruments
Hygro-Thermograph
Recording instrument for rel. air
humidity and air temperature
The housing consists of a
plastic-metal combination.
The axes are supported by
pivot bearings.
Two different models are
available regarding the drum
clockwork drive:
1. Mechanical drum clockwork
with hand wound drive for
the temperature range from
-35 … +80 °C (for model
1.0660 / 664..)
2. B
attery-operated quartz
clockwork for the temperature range from -20 … +60 °C
(for model 1.0665..)
Included in delivery:
1 set (100 sheets) strip chats
2 pieces felt pens
* t he measuring range is possible only with mechanical
clockwork
** the measuring range is
possible only with measuring
element „H“.
Humidity
Measuring range
Graduation
Accuracy
Temperature
Measuring range
Graduation
Accuracy
Dimension
with feet and hook
with flange for wallmounting
20 ... 100% rel. h.
2% rel. h.
±3% rel. h.
@ room temperature
Weight
+5 ... +45 °C
1 °C
±1 K
Ø 130 x 36 mm
Ø 150 x 36 mm with
model with mounting
flange
0.45 kg
1.0665.xx.xxx
Recording time
1 day
7 days
14 days
31 days
1 / 7 / 31 days
Thrust
11.45 mm/h
40 mm/d
20 mm/d
9 mm/d
see above
.00.
.02.
Measuring range
10 ... 100% rel. h.
0 ... 100% rel. h.
Hum. meas. element
H (-35 ... +70 °C)
K (0 ... +80 °C)
.0xx
.9xx
non lockable
lockable
.x00
.x05
.x11
.x12
.x14
.x15
.x16
.x17
Temp. meas. range
-35 ... +45 °C * / **
-20 ... +60 °C **
-10 ... +50 °C **
-10 ... +40 °C **
0 ... +40 °C
0 ... +50 °C
0 ... +60 °C
0 ... +80 °C
1.0660.xx.xxx
1.0664.xx.xxx
Graduation
1 °C
1 °C
1 °C
1 °C
0.5 °C
0.5 °C
1 °C
1 °C
Accuracy rel. humidity
H-meas. element
±2% rel. h.
+1 scale division
@ 65% rel. h. and
room temperature
K-meas. element
±3% rel. h.
+1 scale division
@ 65% rel. h. and
room temperature
Accuracy temperature ±1% of the m. r.
+1 scale division
@ 65% rel. h. and
room temperature
Recording width
2 x 82 mm
Graduation
5% rel. h. /
1 resp. 0.5 °C
Dimension
280 x 138 x 285 mm
Weight
2.7 kg
27
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
Hygro-Thermograph
1.0680.xx.xxx
Recording time
1 day
7 days
31 days
Recording instrument for rel.
air humidity and air temperature.
The housing upper part
consists of crystal-clear plastic. The axes are supported by
pivot bearings.
Battery-operated (1.5 V)
quartz drum clockwork mechanism. The recording time is
switchable.
.10
.12
.011
.014
* the measuring range is
possible only with measuring
element „H“.
Accessories
(100 pcs)
For Hygro-Thermograph
Attention: Pay attention to
the measuring ranges !
Temp. meas. range
-10 ... +50 °C *
0 ... +40 °C
Graduation
1 °C
0.5 °C
Meas. element H
35 … +45 °C
-20 … +60 °C
-10 … +50 °C
0 … +40 °C
0 … +80 °C
Meas. element K
0 … +40 °C
0 … +80 °C
1 day
205142
205143
205138
205123
205126
1 day
205131
205134
7 days
205086
205088
205092
205094
205103
7 days
205097
205112
14 days
205153
205158
205155
205150
205280
14 days
205151
205282
31 days
205169
205168
205166
205160
205281
31 days
205161
205283
Felt Pen 500847
colour
violet
Console
1.0598.10.000
Material
Surface
Weight
Aluminium, varnished
280 x 140 mm
0.8 kg
For wall-mounting of the
hygro-thermographs, order
no.. 1.0660... to 1.0665...
28
Humidity meas. range Hum. meas. element
10 ... 100% rel. h.
H (-35 ... +70 °C)
0 ... 100% rel. h.
K (0 ... +80 °C)
Accuracy rel. humidity
H-meas. element
±2% rel. h.
+1 scale division
@ 65% rel. h. and
room temperature
K-meas. element
±3% rel. h.
+1 scale division
@ 65% rel. h. and
room temperature
Accuracy temperature ±1% of the m. r.
+1 scale division
@ 65% rel. h. and
room temperature
Recording width
2 x 82 mm
Graduation
5% rel. h. / 1 resp.
0.5 °C
Dimension
280 x 138 x 285 mm
Weight
2.7 kg
Included in delivery:
1 set (100 sheets) strip chats
2 pieces felt pens
Recording Charts
Thrust
11.45 mm/h
40 mm/d
9 mm/d
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
Meteorograph
1.0840.00.xxx
.000
.005
Measuring range
temperature
A triple recording instrument
for the most important meteorological data temperature,
rel. humidity, and barometric
air pressure. Approved sturdy
model with mechanical drum
clockwork and hand wound
drive.
The housing consists of metal
and is white lacquered. The
axis of the measuring systems
are supported in pivot bearings.
humidity
pressure
Accuracy
humidity
Hum. meas. elem.
Recording width
Dimension
Weight
±2% rel. h.
+1 scale division
@ 65% rel. h. and
room temperature
±1% of the m. r.
+1 scale division
@ 65% rel. h. and
room temperature
±0.8 hPa
+1 scale division
@ 65% rel. h. and
room temperature
5% rel. h. / 1 °C /
1 hPa
1 day / 7 days
11.45 mm/h;
40 mm/d
H
3 x 82 mm
280 x 140 x 350 mm
4.5 kg
colour
violet
1 day
205197
205073
7 days
205192
205190
temperature
pressure
Included in delivery:
1 set (100 sheets)
strip chats
3 pieces felt pens
-35 ... +45 °C
-20 ... +60 °C
10 ... 100% rel. h.
945 ... 1052 hPa
Graduation
Recording time
Advance
Accessories
Felt Pen
Recording Charts
(100 pcs.)
For Meteorograph
500847
temp. range
-35 … +45 °C
-20 … +60 °C
29
Humidity
Temperature
Pressure
Description
Electronic Hand
Instruments
Hygro-Thermometer 625
Digital portable measuring
instrument with integrated
measuring sensor for the
measurement of rel. humidity
and temperature.
Order No.
1.8625.10.000
Accuracy
Display
Resolution
Supply
The instrument is equipped
with a “hold function”
for ­holding the displayed
­measuring instrument.
­Included in delivery: p
­ ortable
measuring instrument,
­pluggable sensor, battery,
and calibration protocol.
Operating time
of battery
Housing
Dimension
Weight
Accessories
Hand grip for
measuring sensor
1.8625.11.725
Carrying Case
1.8625.20.210
Topsafe (protective cover)
1.8625.20.221
DKD Certificate
1.8625.90.206
ISO Certificate
1.8625.90.006
Battery Charger
1.8625.30.025
9 V Accumulator
1.8625.30.515
Hand grip for pluggable humidity sensor head for connection
to hygro-thermometer 625
inclusive sensor cable.
Protects against shock and dirt
11.3% and 75.3% rel. h.
@ +25.0 °C
11.3% and 75.3% rel. h.
@ +25.0 °C
For external charging
of the accumulators
30
Measuring sensor
Temperature
Rel. humidity
Measuring range
Display:
• Rel. humidity
• Wet bulb temperature
• Dew point temperature
• Temperature
• Max.- and min. values
For measuring instrument
and sensor
Technical Data
NTC
capacitive
-10 ... +60 °C
0 ... 100% rel. h.
±0.5 K
±2.5% rel. h.
(5 ... 95% rel. h.)
LCD, approx. 14 mm
high, illuminated
0.1 °C / 0.1% rel. h.
9 V-block battery,
6F22
approx. 70 hours
synthetic (ABS)
182 x 64 x 40 mm
195 g
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
1.1005.50.xxx
.015
.515
Electr. output
200  lin./ Pt 100
200  lin./ Pt 100
Electr. connection
with Lemosa-plug
with 3 m cable
Measuring range
Accuracy
Diameter of stem.
Length of stem
Protection
Total length
Weight
10 ... 100% rel. h.
±3% rel. h.
@ 20 ... 100% rel. h.
and room temperature
±1 k
1% rel. h. not linear
94 mm
H
Pt 100, acc. to
DIN IEC 60751
1/3 class B
22 mm
250 mm
IP 65, display case
350 mm
0.7 kg resp. 0.9 kg
Electr. output
Humidity
0…1V
0…1V
0 … 10 V
0…5V
4 … 20 mA
Electr. output
Temperature
Pt 100
0…1V
0 … 10 V
0…5V
4 … 20 mA
Measuring range
0 … 100% rel. h.
-30 … +70 °C
Electrical Transmitter
Hygro-Thermo Transmitter
Instrument designed for
­measurement of temperature
and air ­hu­mi­dity. The data are
output as electrical analogue
signals. Humi­d­ity value is
­displayed additionally.
The transmitters consist of a
hair humidity element and a
Pt 100 resistance t­ hermometer.
Sturdy construction, essential
external parts are made of
stainless steel. For outdoor
installation we re­commend
the use of the weather- and
thermal radiation shield order
no. 1.1025.51.000.
(see Accessories)
Hygro-Thermo
Transmitter compact
Instrument designed for
measurement of temperature
and air humidity The data are
output as electrical analogue
signals The transmitters consist
of a capacitive humidity element and a Pt 100 resistance
thermometer.
For outdoor installation we
recommend the use of the
weather- and thermal radiation
shield.
Order no 1 1025 55 xxx
Graduation
Scale length
Hum. meas. elem.
Temp. meas. elem.
1.1005.54.xxx
.000
.160
.161
.173
.241
Meas. element
Rel. humidity
Temperature
Accuracy
Rel. humidity
Temperature
Operating voltage
Protection
Connection
Dimension
Weight
Hygro-Thermo
Transmitter compact
Model like 1.1005.54.xxx,
however with extended temp.
measuring range.
1.1005.54.xxx
.441
.461
Electr. output
Rel. humidity
4 … 20 mA
(= 0 … 100% rel. h.)
0 … 10 V
(= 0 … 100% rel. h.)
Capacitive
Pt 100 acc. to
DIN IEC 60751
1/3 class B
±2% rel. h.
(@ 5 ... 95% rel. h.
and 10 ... 40 °C)
±0.1 K (Pt 100)
±0.2 K (V)
±0.3 K (mA)
1.1005.54.xxx 1.1005.54.241
6 ... 30 V DC
(...000/160)
15 ... 30 V DC (...161)
10 ... 30 V DC (...173)
12 ... 30 V DC (...241)
IP 30 for sensor
IP 65 for electronic
5 m cable
Ø 20 x 124(180) mm
0.45 kg
Temperature
4 … 20 mA
(= -40 ... +60 °C)
0 … 10 V
(= -40 ... +60 °C)
31
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
Hygro-ThermoTransmitter compact
1.1005.54.xxx
Electr output
Rel. humidity
0 ... 1 V
0 ... 10 V
0 ... 5 V
Electr. output
Temperature
Pt 100 (±0.1 K)
0 ... 10 V (±0.2 K)
0 ... 5 V (±0.2 K)
Connection
Dimension
Weight
Plug connection
Ø 20 x 190 mm
0.45 kg
Measuring range
0 ... 100% rel. h.
-40 ... +85 °C
• Model with plug
Model like 1 1005 54 xxx,
however with plug and socket
instead of fixed cable
Hygro-Thermo
Transmitter compact
The instrument serves for the
measurement of temperature
and air humidity.
The data communication is
carried out via an RS485interface with MODBUS RTUprotocol.
The sensors consist of a
capacitive humidity element
and a pt 100 resistance thermometer.
For outdoor installation we
recommend to use the weather
and thermal radiation shield
order-no 1.1025.55.00x
32
.701
.761
.773
1.1005.54.780
Measuring element
Rel. humidity
Temperature
Accuracy
Rel. humidity
Temperature
Electr. output
Operating voltage
Protection
Connection
Dimension
Weight
Capacitive
Pt 100 1/3 class B
acc to DIN IEC 751
±1.5% rel. h.
(@ 10...90% rel. h.
and 23 °C)
±0.2K (@ 23 °C)
RS485, MODBUSRTU-protocol
5 ... 30 VDC
IP 30 for Sensor
element
IP 67 for plug
7 pole connector
Ø 20 x177 mm
0.45 kg
Humidity
Temperature
Pressure
Description
Order No.
Membrane Filter
with gauze ZE 20
1.1005.54.901
Sinter Filter ZE 21
1.1005.54.902
Wall Holder
1.1005.54.903
Technical Data
Is put on the sensor and
­protects the ­measuring element from coarse dust.
made of metal.
Is put on the sensor and
­protects the ­measuring element from high wind speeds
(> 5 m/s) and coarse dust.
Necessary for use in exposed
areas (e.g. sea climate).
Serves for wall mounting of
hygro-thermo ­transmitter
1.1005.54…, for use ­protected
against radiation and
­precipitation (for ex. indoor).
Weather and Thermal
Radiation Shield
Protective case for hygro-­
thermo transmitter compact
with outdoor installation.
Clamping range
Wall distance
Material
Mounting
Dimensions
Weight
1.1025.55.00x
.10x
.xx0
.xx1
W/o Ventilator
with Ventilator
Clamping range
Material
Montage
cable
Dimensions
Weight
Ø 20 mm
83 mm
(to transmitter centre)
plastic, grey
flange plate with
3 x 6.5 mm boring
96 mm long
0.075 kg
12 V DC; 2 W
Ø 35 … 50 mm
Ø 55 … 60 mm
Synthetic lamellas,
white
Non-corroding holder
5 m, for model. ...100
Ø 120 x 275 /
290 mm
0.8 kg
33
Humidity
Temperature
Pressure
Description
Order No.
Clima Sensors D
Clima Sensor D, WTF
Wind Precipitation, Brightness Temperature
Twilight
Air Humidity 4.9110.00.061X
X
X
Clima Sensor D, W
4.9100.00.061X
X
Clima Sensor D, TF
4.9111.00.061
X
Clima Sensor D
4.9101.00.061
X
The Clima Sensor D serves
for the measurement of
environmental data. These
are available as
• Serial RS 485/422
telegram and as
• Analogue outputs
for further processing
Wind
Measuring range
Accuracy
Precipitation
Measuring range
Sensitivity
Switch-off-delay
1 … 40 m/s
±0.5 m/s or ±5%
of measuring range
Precipitation yes/no
Fine drizzle
Approx. 2 minutes
Brightness
for South
East, West
Measuring range
Spectral range
Accuracy
0 … 100 k Lux
700 … 1050 nm
±10% of meas. value
Twilight
Measuring range
Spectral range
Accuracy
0 … 250 Lux
700 … 1050 nm
±10% of meas. value
Temperature
Measuring range
Measuring element
Accuracy
-20 … +60 °C
Pt 100 1/3 DIN
±0.5 k at > 1 m/s
Air humidity
Measuring range
0 … 100% rel. h.
Accuracy
±3% in the range
10 … 90% rel. h.
Type
Output
RS 422 / 485
1200-19200 baud
8N1, full-duplex/
half-duplexoperation
Environmental data,
housing, temperature,
date, time, sensor
status, checksum
The Clima Sensor D has an
internal DCF77 receiver, which
takes the time signal of an
atomic clock, and integrates
it into the data telegram.
Ranges of application are:
• Building control systems
• Control technique
• Green house technique
• Processing of the acquired
data to recording or display
instruments
Depending on the model,
the following data can be
measured by the Clima
Sensor D:
• Wind velocity
• Precipitation (yes/no)
• Brightness in Eastern,
Southern and Western
direction
• Twilight
• Temperature
• Rel. humidity
Output
serial
Output parameter
analogue
The respective holder serves
for the mounting at masts or
plane surfaces, depending on
the range of application.
Instrument with internal
condensation shield
Technical Data
Signal
0 … 10 V
0 V/10 V
Load resistance
General
Operating voltage
Current consumption
Weight
4.9110.00.061
4.9100.00.061
4.9111.00.061
4.9101.00.061
Ø 130 x 430 mm
Ø 130 x 335 mm
Ø 130 x 310 mm
Ø 130 x 215 mm
Mounting
34
Depending on
parameter
With precipitation
yes/no
≥ 10 kΩ
≥ 100 kΩ with
precipitation
16-28 VDC or 24 V AC
≤ 150 mA w/o
condensation shield,
approx. 600 mA with
condensation shield
-40 °C … +60 °C
10 m cable; LiYCY
16 x 0.14 mm² ,
UV-resistant
Retaining clamp,
stainless steel
max. 1.5 kg
Ambient temperature
Connection
Dimension
X
Humidity
Temperature
Pressure
Description
Order No.
Weather Stations
Technical Data
Temperature
HumidityPrecipitation
Wind Pressure Brightness Configuration
Clima Sensor US NHTFB
4.9200.00.000
Clima Sensor US TFB
4.9201.00.000
XX
10V/RS485
Clima Sensor US NH
4.9202.00.000
X
10V/RS485/GPS
Clima Sensor US
4.9203.00.000
X10V/RS485
The Clima Sensor US serves
for the measurement of
­environmental parameters.
These are available for further
processing as
• Serial telegram via an
RS485/422 and /or as
• Analogue Signals via ­
voltage output
Wind Velocity
Measuring range
Accuracy
0 ... 60 m/s
±0.2 m/s @ WV <5 m/s
±3% @ WV >5 m/s
Wind Direction
Measuring range
Accuracy
0 ... 360°
±2.0° @ WG >2 m/s
Precipitation
Measuring range
0.001 ... 10 mm/min
Brightness
Some models have a
GPS receiver. It serves for
­determining position and time, Air pressure
here from, the sun position is
calculated additionally.
Position, time and sun
Temperature
position are output serially.
Measuring range
0 ... 150 kLux
3% from rel. meas.
value
Measuring range
Accuracy
300 ... 1100 hPa
±0.25 hPa @
+10 … +35 °C
Measuring range
Accuracy
-40 ... +80 °C
±0.2 K @ 25 °C
Measuring range
Accuracy
0 ... 100% rel. h.
±1.8% @ 10 ... 90%
rel. h.
Type
Baud rate
Operating mode
Protocol
Output parameter
RS 422 / 485
1200 ... 921600 baud
full-duplex /
half-duplex
ASCII / MODBUS RTU
Div. meas. data, date,
time, check sum etc.
Type
Output parameter
8 x 0 … 10 V
Wind velocity and
direction, brightness,
direction of brightness, precipitation, rel.
humidity, temperature,
air pressure
≥ 2 kΩ
5 ... 60 VDC or
10 ... 42 VAC 50/60 Hz
50 mA @ 24 V
Compact design, easy
Air humidity
­mounting, and the various
possibilities for data output
are the basis for an application
in many fields, such as.
Output
• Building control, Traffic
serial
control system, Meteoro­
logy, Renewable energy,
­Agriculture.
Depending on model, the
following parameters can
be measured by the Clima
Sensor US:
• Wind velocity
• Wind direction
• Precipitation intensity
and kind
• Brightness
• Brightness direction
• Temperature
• Relative air humidity
• Air pressure
analogue
General
X
XX10V/RS485/GPS
X
Load resistance
Operating voltage
Power consumption
(Electronics fully
equipped)
Heating at full power
Ambient temperature
Connection
Mounting
Dimension
Weight
24 V AC / DC 25VA
-30 °C ... +70 °C
19-pole connector
On tube
(max. Ø 50 mm)
0.9 / 0.7 kg
4.9200(1).00.000
4.9202(3).00.000
Ø 150 x 220 mm
Ø 150 x 175 mm
35
Humidity
Temperature
Pressure
Description
Order No.
Technical Data
Cable
509311
Length
Number of leads
10 m
16
509427
Length
Number of leads
10 m
8
9.3389.20.000
Primary
Secondary
Series terminals
Housing
Dimensions (LxWxH)
Screwed cable gland
Protection
Weight
230 V AC / 115 V AC
24 V AC / 1.25 A
16
Plastic material
125 x 125 x 100 mm
3 x M 16 x 1.5
1 x M 20 x 1.5
IP 66
approx. 1.5 kg
Clamping range
Material
Weight
Ø 48 … 102 mm
Stainless steel
approx. 0.5 kg
Pre-assembled connecting
cable for Clima Sensor US
The cable with 16 leads serves
for the connection of:
• Serial interface
• Analogue output
• Instrument supply
The cable with 8 leads serves
for the connection of:
• Serial interface
• Instrument supply
Equipment:
• Plug at the instrument side,
• Open cable end receiving side,
• Shielded,
• Halogen-free,
• UV-resistant
Power Supply Unit
Serves for power supply of the
Clima Sensor US as well as
for the connection and distribution of cable or cable wire resp.
Equipment:
toroidal transformer, series
terminal, housing with screwed
cable gland
Mounting set
Serves for lateral mounting
of power supply unit
9.3389.20.000 at a mast
36
509436
Humidity
Temperature
Pressure
Description
Order No.
Weather Station Compact
WSC11
4.9056.00.000
The Weather Station Compact
WSC11
is designed for the use in
• Building automation
(such as. shading control)
Wind Velocity
Measuring range
Accuracy
0 ... 40 m/s
±5% of meas. range
Wind Direction
Measuring range
Accuracy
0 ... 360°
±10°
Measuring range
1 / 0 (yes/no)
Measuring range
Accuracy
0 ... 150 kLux
±3% of meas. range
Twilight
Measuring range
Accuracy
0 ... 500 Lux
±10 Lux
Global radiation
Measuring range
Accuracy
0 ... 1300 W/m²
±10% of meas. range
Air pressure
Measuring range
Accuracy
300 ... 1100 hPa
±0.5 hPa @ 20 °C
Temperature
Measuring range
Accuracy
-30 ... +60 °C
±1 °C
@ -5 °C ... +25 °C,
>2m/s)
Air humidity
Measuring range
Accuracy
0 ... 100% rel. h.
±5% rel. h.
@ 0 … 40 °C
Output
serial
Type
Baud rate
Operating mode
Protocol
RS 485
1200 ... 115200
Half-duplex
ASCII / MODBUS RTU
Operating voltage
Weight
Dimension
18 ... 30 VDC or
18 ... 28 VAC 50/60 Hz
<300 mA @ 24 VDC
-30 °C ... +60 °C
connector
On tube
(max. Ø 25 mm)
0.2 Kg
Ø130 x 70 mm
The interface to the instrument Precipitation
is digital and consists of an
Brightness
• RS485 interface in
half-duplex-mode
Together with the ID-based
communication the interface
allows the operation of the
weather station in a bus
The instrument has a GPS
receiver. It serves for determining the position and time.
Herefrom, the sun position is
calculated additionally
The following parameters can
be measured:
• Wind speed
• Wind direction
• Brightness (in the North,
East, South, West)
• Twilight
• Global radiation
• Precipitation
• Temperature
• Relative humidity
• Air pressure
• Time / Date
• Geostationary data
-Longitude
-Latitude
• Sun position
-Elevation
-Azimuth
Technical Data
General
Power consumption
Ambient temperature
Connection
Mounting
Mounting angle
509276
Length
width
Material
320 mm
60 mm
Stainless steel 1.4301
Cable
509279
Length
5m
Serves for the lateral mounting of the Weather Station
Compact WSC11 at a vertical
surface
Pre-assembled 5-pole
­connecting cable for Weather
Station Compact WSC11.
Equipped with:
• Plug at the instrument side,
• Open cable end receiving
side,
• Shielded
37
Accessories
Description
Order No.
Technical Data
1.1025.51.000
Suitable for
Weather and Thermal
Radiation Shield
Weather and Thermal
Radiation Shield
Installation pin
Material
Serves as a protective case for
- Hygro-Transmitter
or
- Hygro-Thermo Transmitter
in outdoor use.
This case essentially eliminates the influence of weather
and radiation errors which
affect the measurement result.
Weather and Thermal
Radiation Shield, ­compact
Serves as a protective case for
- Temperature -Sensor compact
or
- Hygro- Thermo Transmitter
compact in outdoor use.
This case essentially eliminates the influence of weather
and radiation errors which
affect the measurement result.
Dimension
Weight
1.1025.55.xxx
Suitable for
1.1025.55.00x
1.1025.55.10x
1.1025.55.xx0
1.1025.55.xx1
Without ventilator
With ventilator
Clamping range
(holder)
Material
Lamella
The Universal Amplifier serves
for the connection of various
sensors with voltage-, or PT
100 output. It amplifies the
measuring values, prepares
them and outputs them as
standardized voltages or currents analogical and digitally.
Analogue outputs:
Measuring values are, alternatively, output as current- or
voltage signal.
The scaling of the measuring
values are settable.
Digital output:
An RS485/422 is available for
serial communication (operation, scaling and telegram
output). It can be operated in
full- or resp. half-duplex mode.
For the output of measuring
values there are pre-defined
telegrams available.
All settings/programmings are
carried out in the factory.
38
1.1005.54…
2.1280…
12 V DC, 2 W
Ø 35 … 50 mm
Ø 55 … 60 mm
Polycarbonat, white,
UV-resistant
Holder
Stainless steel
Cable (execution only 5 m
1.1025.55.10x)
Dimension
Ø 120 x 275/290 mm
Weight
0.8 kg
Measuring Transformer
Universal Amplifier
1.1000.50...
1.1005.50...
Ø 22 x 27 mm
aluminium galvanised
and varnished
Ø 170 x 450 mm
2.2 kg
7.1415.00.200
Analogue inputs
4 x -0.1 ... +1.0 V;
resolution 1 µV
switchable to
-1 ... +10 V
Alternatively, each
channel is switchable
to PT 100: max.
-99.0 … +99.0 °C
PT100 resolution:
1/10, 1/100,
1/1000 °C, settable
Analogue outputs
0 … 1 V, 0 … 5 V,
0 ... 10 V, 4 … 20 mA,
0 … 20mA
Resolution
1/10000 FS
Serial interface
1 x RS422/485
Baud rates: 1200,
2400, 4800,
9600(default),
115200Bd, 8N1
Operating voltage
Ambient conditions
Operating temperature
Storage temperature
Housing
Type of connection
7 ... 42 V DC
Protection
Dimension
Weight
-40 ... +60° C
-40 ... +85° C
Polycarbonate
Cable gland and
terminal strip
IP 65
120 x 80x 55 mm
0.25 kg
Accessories
Description
Order No.
Technical Data
1.1044.00.xxx
1.1044.02.xxx
2.1044.00.xxx
3.1044.00.xxx
.000
.040
.041
.061
.073
Display range
Digital Indicators
Digital Indicator
for panel installation
Flat-section indicator
for ­display of humidity, ­temperature or pressure
­values. The background
of the indicator is black
to ­facilitate reading of the
red digits.
Preferably switch panel or
front panel installation.
Digital Indicator
for panel installation
with 2 adjustable limit contacts Flat-section indicator for
display of humidity, temperature or pressure values.
Two setting knobs on the
front panel serve for setting
both the potential-free relaycontacts.
The background of the
­indicator is black to facilitate
reading of the red digits.
Preferably switch panel or
front panel installation.
Electr. input
Resolution
Display
Operating voltage
Model
Protection
Dimension
Weight
1.1045.00.xxx
1.1045.02.xxx
2.1045.00.xxx
3.1045.00.xxx
.000
.040
.041
.061
.073
Display range
Electr. input
Resolution
Display
Type of contact
Operating voltage
Model
Protection
Dimension
Weight
10 ... 100% rel. h.
0 ... 100% rel. h.
-100.0 ... +199.9 °C
945 ... 1053 hPa
Pt 100 ( only temp. )
0 ... 20 mA
4 ... 20 mA
0 ... +10 V
0 ... +5 V
(only pressure)
±1 digit
LED, red, 13 mm high
230 V / 50 Hz
panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
10 ... 100% rel. h.
0 ... 100% rel. h
-100.0 ... +199.9 °C
945 ... 1052 hPa
Pt 100 ( only temp.)
4 ... 20 mA
0 ... 20 mA
0 ... +10 V
0 ... +5 V
(only pressure)
±1 digit
LED, red, 13 mm high
throw over switch
230 V / 50 Hz
panel mounting
IP 20
96 x 48 x 104 mm
0.3 kg
39
Accessories
Description
Order No.
Technical Data
Weather Display LED
9.2750.0x.900
.00.
Operating voltage
Displaying ­measuring ­instru­ment for four ­meteoro­logical
parameters (for ex. temperature, rel. humidity, global radiation, air pressure). Instrument
with serial interface for the
receipt of measuring data and
output to processing systems.
.01.
Display range
Display
Measuring range
• Operation and setting
through front side keys.
• Display sequence and
­formatting of weather
­parameters are configurable
acc. to customer’s request.
•D
isplay possible from
­instantaneous, min., max.
and mean value for each
parameter.
•R
eceipt of display parameters
via a serial interface.
For ex. for connection to
­THIES-­datalogger systems
or THIES-sensor interface.
•O
utput of display parameters
via a serial interface.
Weather Display LED
Displaying ­measuring
­instrument for four
­meteoro­logical parameters (for
ex. temperature, rel. humidity,
global radiation, air pressure).
Instrument with integrated ­serial interface and
­analogue-interface for data
input and -output
The instrument is optionally
equipped with an integrated
pressure sensor.
• Operation and setting
through front side keys.
• Display sequence and
­formatting of weather
­parameters are configurable
acc. to customer’s request.
• Display possible from
­instantaneous, min., max.
and mean value for each
parameter.
40
Measuring value input:
•R
eceipt of display parameters
via a serial interface
•R
eceipt and acquisition of
the display parameters via an
integrated analogue ­interface.
The analogue IF is configurable
acc. to customer’s request.
•S
erial output of the display
para­meters via a serial
­interface.
• Analogue output of max. two
display parameters via an
integrated analogue interface
(U/I is selectable).
Resolution
Digital-Interface
Type
Baud rate
Parameter
Temperature range
Construction
Dimension
Protection
Weight
EMC
9.2750.xx.901
.x0.
Operating voltage
.x1.
.0x.
.1x.
W/o integrated
pressure sensor
With integrated
pressure sensor
Display range
Display
Measuring range
Resolution
Digital interface
Type
Baud rate
Parameter
Analog input
Analog output
Temperature range
construction
Dimension
Protection
Weight
EMC
Pressure sensor
Measuring range
Resolution
Accuracy
230 V / 50 Hz; 24 V AC
12-35 V DC
115 V / 50 Hz; 24 V AC
12-35 V DC
-9:999 … +99999
4 x 5 digit, LED red,
14 mm high
4 x min/max
LED-arrow
depending on
parameter
depending on
parameter
1 x RS 422
1200, 2400, 4800,
9600, 19200, 57600
for ex. 8N1, 7E1,
-10 … 50 °C
Switch panel
mounting
144 x 144 x 135 mm
IP 23
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
230 V / 50 Hz; 24 V AC
12-35 V DC
115 V / 50 Hz; 24 V AC
12-35 V DC
-9.999 … +99999
4 x 5 digit, LED red,
14 mm high
4 x min/max
LED-arrow
depending
on parameter
depending
on parameter
1 x RS 422
1200, 2400, 4800,
9600, 19200, 57600
for ex. 8N1, 7E1,
3 (4) x 0 ... 10 V or
0 (4) ... 20 mA
1 x Pt 100
2 x 0 ... 10 V or
0 (4) ... 20 mA
-10 … 50 °C
Switch panel mounting
144 x 144 x 135 mm
IP 23
1.5 kg
EN 60945
EN 61000-6-2
EN 61000-6-3
750 ... 1100 hPa
0.1 hPa
±0.5 hPa (at 25 °C)
Accessories
Description
Order No.
Technical Data
Hangers / Holders /
Adapters
Hanger 1 m
For mast mounting of a
­measuring value transmitter.
Bracket with adapter for
hygro-thermo transmitter
(1.1005.50..) in the weather
and thermal radiation
shield (1.1025.51...) or for
air temperature transmitter
(2.1260.00.000)
Traverse 0,2 m compact
For storefront mounting of a
measuring value transmitter.
4.3185.xx.xxx.
.00.
.01.
.02.
.000
.001
Clamping range
Suitable for
Sensor distance
Dimension
Tube diameter
Material
Weight
Ø 60-132 mm
Ø 40-80 mm
Ø 48-50 mm
1.1005.50./
1.1025.51.
2.1260...
1 m from mast
1 m long
50 mm
Aluminium
1.8 kg
4.3171.25.000
Length
Material
Weight
200 mm
Aluminium
0.3 kg
4.3171.30.000
Clamping range
Sensor distance
Dimension
Material
Ø 48 ... 102 mm
0.4 m from mast
0.8 m long
Aluminium /
Stainless steel
0.35 kg
For adapting of measuring value transmitter pivots (506350)
and holders (506347) can be
used.
Traverse
For combined mounting of
2 measuring value transmitters onto a mast
Weight
For adapting of measuring value transmitter pivots (506350)
and holders (506347) can be
used.
Traverse NS/TF –
04 m /0.8 m
For combined mounting of
2 measuring value transmitters onto a mast.
Traverse with adapter for
hygro-thermo transmitter
(1.1005.54..) in weather and
thermal radiation shield
(1.1025.55...) and precipitation
monitor (5.4103.. / 5.4105..)
4.3171.30.012
4.3171.31.012
Clamping range
Clamping range
Transmitter distance
Dimension
Material
Weight
Ø 48 ... 102 mm
Ø 116 ... 200 mm
0.4 m and 0.8 m
from mast
1.2 m long
Aluminium /
Stainless steel
1.1 kg
41
Accessories
Description
Order No.
Technical Data
Traverse short
4.3171.40.000
Clamping range
Transmitter distance
Dimension
Material
Weight
Ø 48 ... 102 mm
0.4 m to the Mast
0.4 m long
Aluminium /
stainless steel
0.30 kg
506347
Clamping range
Dimension
Material
Weight
35 ... 50 mm
80 x 150 mm
Stainless steel
0.35 kg
Peg complete
506350
Material
Dimension
Weight
POM
Ø 40 x 65 mm
0.1 kg
Wall Holder
1.1005.54.903
Clamping range
Average wall distance
Material
Mounting
Ø 20 mm
83 mm
Plastic, grey
Flange plate with
3 x 6.5 mm boring
96 mm long
0.075 kg
For mast mounting of a measuring value transmitter.
For adapting of measuring value
transmitter pivots (506350) and
holders (506347) can be used.
Holder compact
For mounting of measuring
value transmitter onto a mast,
tube, traverse or at a storefront.
For adapting of measuring value
transmitter pivots (506350) and
holders (506347) can be used.
For adapting of measuring value
transmitters, for ex.
for hygro-thermo transmitters (1.1005.54..) in weather
and thermal radiation shield
(1.1025.55...) at a/m traverses
or holders
For mounting of a hygro-thermo
transmitter (1.1005.54...) or
temperature sensor (2.1280....)
at a wall, radiation- and precipitation-protected application
(for ex. in rooms)
Mounting angle
Serves nfor the lateral mounting of the weather station
COMPACT WSC 11 at a vertical
surface
42
Dimension
Weight
509276
Length
Width
Material
Please contact us for other accessories, such as cables and cable connections
as well as for additional constructions of masts or systems.
We will be pleased to submit an individual offer to you.
320 mm
60 mm
Stainless steel
1.4301
THIES­ –
as versatile as the international
tasks require
THIES-CLIMA – Worldwide
Weather and environmental monitoring technology
needs a competent partner
Climatic measurement and
intelligent analysis are international tasks. They do not
only demand a worldwide
cooperation of the responsible
authorities, but also a comprehensive network of sensors
and analytical systems.
We have developed a smoothly
functioning system of partners
and subsidiaries throughout the
world to provide expert advice
there where you need it.
THIES assumes complete supervision of the tasks at hand, from
project planning to the installation of the system, from staff
training to the processing of the
measurement results.
Should you want to contact
one of our foreign partners,
please write or call us first in
Göttingen. We will provide you
with the exact address.
Phone +49 551 7 90 01-0
Fax +49 551 7 90 01-65
E-Mail [email protected]
www.thiesclima.com 010127/05/13
ADOLF THIES GMBH & CO KG
MeteorologyEnvironmental Technology
Box 3536 + 3541
D-37025 Göttingen
– Alterations reserved –
Information is everything.
Please ask for our complete catalogue and product
descriptions concerning all
questions of weather data
acquisition – or attend our
internet page:
www.thiesclima.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement