Petroleum Testing Equipment
0-KoehlerCat2012Covers9_Layout 1 12/10/12 12:21 PM Page 1
Petroleum Testing Equipment
1595 SYCAMORE AVENUE
BOHEMIA, NEW YORK 11716-1796
1-800-878-9070 (IN U.S. ONLY)
TEL: +1 631 589 3800
FAX: +1 631 589 3815
www.koehlerinstrument.com
Email: sales@koehlerinstrument.com
offices in
BOHEMIA, NEW YORK • HOUSTON, TEXAS
Petroleum Testing Equipment
www.koehlerinstrument.com
BOHEMIA, NEW YORK • HOUSTON, TEXAS
© 2013-2014
Koehler Instrument Company, Inc.
0-KoehlerCat2012Covers9_Layout 1 12/10/12 12:22 PM Page 2
Worldwide Support
Providing quality testing instrumentation and technical support
services for research and testing laboratories has been our
specialty since 1925. Meeting your testing needs is the primary
focus of our business, which is why Koehler Instrument
Company is a leading producer and supplier of petroleum,
synfuels and petrochemical instrumentation worldwide.
At Koehler, we pride ourselves in innovation. In a time of
continuous technological advancement and transition we are
constantly implementing new and improved ways to surpass
the needs of an ever-evolving industry.
Koehler products are backed by our staff of technically
knowledgeable, trained specialists who are experienced in
both petroleum products testing and instrument service, which
is carried out either on site or at a Koehler service center.
Koehler Instrument Company
Is Proud To Be An Active ASTM Member
For Over Half A Century
With this catalog, we are pleased to present our comprehensive
line of petroleum laboratory instrumentation, both manual and
automatic, as well as standards and accessories conforming to
the latest ASTM, ISO, IP and related international specifications.
We invite you to look through our extensive product offerings
for instrumentation and services to meet your testing needs, or
contact us for custom solutions for your specialized requirements.
Committed to providing you with full support for your laboratory
testing needs, Koehler Instrument Company is more than just an
instrument manufacturer. We take care of you through the whole
process. We have many satisfied customers worldwide and
continue to build new relationships every day because of our
attention to customer needs. Our goal is to be the best and most
dependable instrument company in the market place. We invite
your comments and input so that we may continue to serve you.
www.koehlerinstrument.com
www.koehlerinstrument.com
BOHEMIA, NEW YORK • HOUSTON, TEXAS
0-KoehlerCat2012IntroAshley4aa3_Layout 1 11/29/12 5:50 PM Page 1
Our philosophy - is to fully understand your needs
before offering technical advice and product solutions.
Koehler's well-trained staff has direct experience and
remains up to date with the test method standards for
which we offer products and services and can knowledgeably
discuss your needs. If one of our standard products does
not fit your particular need, we can guarantee an alternative
solution.
0-KoehlerCat2012IntroAshley4_Layout 1 10/24/12 11:53 AM Page 2
After your instrument is delivered to your laboratory – Our staff
will contact you to answer any questions that you may have and
to make certain that you have everything you need. Koehler
technical service specialists are always just a phone call away
to provide you with information and assistance for your
testing needs.
Certified Documentation – Koehler provides traceable
documentation to support your ISO based quality management
system. This includes traceable certificates for viscometer tubes,
thermometers, hydrometers, thermo-hydrometers and more.
Training Seminars – We match our world class equipment with
world class training. Both our annual and customized training
seminars for any combination of Koehler instruments and test
method standards enable your staff to make the most of your
equipment investment. We actively train laboratory personnel
and our worldwide distributors at our facilities to ensure the best
service to our customers.
Calibration Services and Reference Fluids – Koehler offers a
growing variety of ISO 17025 certified petroleum testing materials
for your calibration and test method validation requirements.
Our Technical Service Department provides calibration services
conducted with traceable reference materials and standards.
Testing Services – A complete source for your testing solutions,
Koehler offers a wide range of in-house services based on
selected standard test methods. Our staff is comprised of
technical experts and the best instrumentation for fast, accurate
and reliable results. We specialize in all tests for which we offer
instrumentation as well as additional test methods. You are
invited to send us samples for testing and evaluation at any
time. Please contact your Koehler representative for additional
information.
Instrument Maintenance and Service – Onsite installation and
service visits are available for any instrument. Should an issue
arise, our trained technicians work to diagnose and resolve it
promptly and efficiently. Detailed service records are kept for
each instrument to assist in recommending future maintenance
or finding a fast solution to a problem, and an extensive stock of
replacement parts is on hand for immediate delivery.
www.koehlerinstrument.com
0-KoehlerCat2012IntroAshley4_Layout 1 10/24/12 11:53 AM Page 3
Table Of Contents
Viscosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Penetration . . . . . . . . . . . . . . . . . . . . . . . . . 23
Flash Point . . . . . . . . . . . . . . . . . . . . . . . . . 31
General Test Equipment
. . . . . . . . . . . 41
Fuels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
Lubricating Oils
. . . . . . . . . . . . . . . . . . 107
Tribology . . . . . . . . . . . . . . . . . . . . . . . . . . 139
Lubricating Greases . . . . . . . . . . . . . . 147
Bitumens and Waxes
Warranty Coverage – Koehler provides a comprehensive warranty
with each purchased instrument. Service contracts and extended
warranties are available for all instruments, which can either be
carried out on site or at one of our Koehler service centers.
Customer Service – Our fast, friendly, knowledgeable sales team
expertly answers any presale or application questions you may
have in placing your order. They make sure every aspect of your
order goes smoothly.
Worldwide Support – Our global network of qualified distributors
provide sales and application support, training, and service
assistance. Contact us for the distributor in your area.
Social Media – Koehler is now on Facebook. “Like” our page
for weekly updates on our latest products, news, events
and tradeshow information. You can find us at
facebook.com/KoehlerInstrument
. . . . . . . . . . . . . . 169
Certified Petroleum Standards . . 181
ASTM Thermometers, Test
Specimens and Glassware . . . . . . . . 183
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . 198
Indexes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 210
0-KoehlerCat2012IntroAshley4_Layout 1 10/24/12 11:53 AM Page 4
How To Order
For most of the ASTM, ISO, FTM and international standards featured in this catalog, you will find a complete offering of the
equipment needed to perform the test. Many instruments are available in several different configurations to enable you to tailor your
selections to your individual requirements. Certain standard laboratory items have not been listed but are available on special order.
Our Customer Service representatives can answer any questions you may have and provide you with information you may require.
Please be sure to use the Koehler catalog number for the instrument model which is compatible with your local power service.
Consult individual product listings for complete information on electrical requirements. All of our products listed in this catalog can
be ordered by phone, fax or e-mail. Orders may also be placed using your Visa, Mastercard, American Express, or Discover Card.
CALL TOLL FREE IN THE U.S.: 1-800-878-9070
PHONE: +1 631 589 3800 • FAX: +1 631 589 3815
E-MAIL: sales@koehlerinstrument.com
offices in
BOHEMIA, NEW YORK • HOUSTON, TEXAS
Koehler offers laboratory reference standards for our full line of testing equipment. Each test standard comes with
original certification listing the ASTM test method, the name and ISO status of each testing laboratory, and the
average test result and standard deviation. Please inquire with Koehler's Customer Service Department about
ordering these reference standards for your testing needs.
0-KoehlerCat2012IntroAshley4_Layout 1 11/1/12 1:48 PM Page 5
Viscosity
Test Methods
Page
Kinematic Viscosity of Transparent and Opaque Liquids
ASTM D445; IP 71; ISO 3104; DIN 51550; FTM 791-305.................2-13
Kinematic Viscosity of Asphalts (Bitumens)
ASTM D2170.........................................................................................2-13
Viscosity of Asphalts By Vacuum Capillary Viscometer
ASTM D2171.........................................................................................2-13
Viscosity and Viscosity Change After Standing at
Low Temperature of Aircraft Turbine Lubricants
ASTM D2532.........................................................................................7-13
Low Temperature Viscosity of Automotive Fluid Lubricants
Measured by Rotational Viscometer ASTM D2983........................14-15
Saybolt Viscosity
ASTM D88; AASHTO T72; FTM 791-304...........................................16-17
Saybolt Furol Viscosity of Bituminous Materials at
High Temperatures ASTM E102........................................................16-17
Viscosity Reference Standards.........................................................18-19
Dynamic Viscosity by Rotational Viscometer..................................20-21
www.koehlerinstrument.com
0-2-11_1a_Visc_Layout 1 10/24/12 10:51 AM Page 2
Kinematic Viscosity
Kinematic Viscosity of
Transparent and Opaque Liquids
Kinematic Viscosity of Asphalts (Bitumens)
Viscosity of Asphalts by Vacuum
Capillary Viscometer
Viscosity and Viscosity Change After Standing at Low
Temperature of Aircraft Turbine Lubricants
Test Method
Kinematic viscosity is of primary importance in the design and selection
of a wide range of petroleum products. Calibrated capillary viscometers
are used to measure flow under gravity or vacuum at precisely controlled
temperatures.
Kinematic Viscosity Test Equipment
• Constant temperature baths for the full range of viscosity applications,
from low temperature to high temperature
• Calibrated glass capillary kinematic viscometers
• Viscosity standards
• Viscometer cleaning and drying apparatus
• Kinematic viscosity thermometers
K23702 Constant Temperature Kinematic Viscosity Bath (KV4000) - page 4
Cannon®-Fenske
Routine
Cannon®-Fenske
Opaque
Ubbelohde
Viscosity Reference Standards - pages 18-19
2
0-2-11_1a_Visc_Layout 1 10/24/12 10:51 AM Page 3
Kinematic Viscosity
KV1000 Digital Constant Temperature Kinematic
Viscosity Bath
• Accommodates six capillary viscometers
• Variable temperature limit control
• Conforms to ASTM D445 and related specifications
Constant temperature bath for kinematic viscosity testing of petroleum products.
Accommodates six round 2" (51mm) dia. viscometer holders. Bath temperature
stabilizes within ±0.5°C (±1°F) of setting, and final adjustment to within
±0.01°C (±0.02°F) can be made. Test temperatures of up to 150°C (302°F) can
be selected. Temperature limit control permits the operator to select an
overtemperature cutoff point to protect against accidental overheating. Control
unit includes immersion heater, circulating stirrer and temperature probe.
Composition top plate rests on a 12x12" (30.5x30.5cm) or 12x18"
(30.5x46cm) Borosilicate Glass jar. Order capillary viscometers, viscometer
holders and thermometer separately.
Specifications
Conforms to the specifications of:
ASTM D445, D6074, D6158; IP 71; ISO 3104; DIN 51550;
FTM 791-305; NF T 60-100
Capacity: Six (6) glass capillary viscometers
Bath Medium: water or white technical oil
Included Accessories
Port Covers, stainless steel (6)
K23376 Digital Constant Temperature Bath
Ordering Information
Catalog No.
Model
Electrical Requirements
Bath Depth
Bath Capacity
Dimensions diaxh,in.(cm) Net Weight
K23376-00000
KV1000
12” (30.5 cm)
5.8 gal (22L)
131⁄2x20 (34.6x50.8)
25 lbs (11.3kg)
115V 60Hz, single phase 10.2A
K23371-00000
KV1000
18” (46 cm)
8.9 gal (33.7L)
191⁄2x23 (49.5x58.4)
38 lbs (17.2kg)
K23377-00000
KV1000
12” (30.5 cm)
5.8 gal (22L)
131⁄2x20 (34.6x50.8)
25 lbs (11.3kg)
220-240V 50/60Hz single phase 5.3A
K23378-00000
KV1000
18” (46 cm)
8.9 gal (33.7L)
191⁄2x23 (49.5x58.4)
38 lbs (17.2kg)
K23377-01000 Cooling Coil Assembly. Permits circulation of water or refrigerated coolant for operation at near ambient temperatures. Installs in top plate.
3
0-2-11_1a_ViscAA_Layout 1 11/29/12 5:59 PM Page 4
Kinematic Viscosity
KV3000 and KV4000 Constant Temperature Baths
with Integrated Digital Timing
• Microprocessor temperature control between ambient and 150°C (302°F)
• Integrated digital timing for easy measurement of sample efflux times
• KV4000 permits entry of viscometer constants for automatic calculation
and display in viscosity units or seconds
• Dual digital displays show setpoint and actual bath temperature
• Selectable temperature scale - Fahrenheit or Celsius
• Integrated redundant overtemperature and low liquid level cut-off circuitry
• Conforms to ASTM D445, D2170 and related specifications
Constant temperature bath series with advanced temperature control circuitry
and integrated timing features for convenient, accurate glass capillary viscometry
determinations. Microprocessor PID circuitry assures precise, reliable
temperature control within ASTM specified tolerances throughout the
operating range of the bath. Simple push-button controls and dual digital
displays permit easy setting and monitoring of bath temperature. Two place
calibration offset capability is provided. Baths accommodate seven glass
capillary viscometers of various types - see pages 10-13 for complete selection.
Viewing the viscometers is made easy by glare-free fluorescent illumination
inside the bath and a baffle that provides a background for easy viewing.
Temperature control uniformity is assured by means of motorized stirrer which
provides complete circulation without turbulence. Connection of the built-in
cooling coil to tap water or a recirculating water chiller facilitates temperature
control at ambient or below ambient temperatures. Communications software
(RS232, etc.) ramp-to-set, and other enhanced features are available at
additional cost. Contact your Koehler representative for additional information.
K23700 Constant Temperature Kinematic Viscosity Bath (KV3000)
Integrated Timing Features - KV3000 incorporates seven digital timers on the
front control panel for convenient timing and monitoring of the efflux interval
for each viscometer. On KV4000, the user can enter the viscosity constant for
each viscometer on the front LCD control/display, and then get the test result
in both efflux time and viscosity units automatically after stopping each timer.
All timing functions are displayed in 0.01 or 0.1 second resolution and are
accurate within 0.01%.
Specifications
Conforms to the specifications of:
ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550;
FTM 791-305; NF T 60-100
Temperature Control
Range: ambient to 150°C (302°F); sub-ambient to 10˚C with
external cooling
Display: 0.1°C/0.1°F resolution, calibrate to 0.01°C/0.01°F
Control accuracy and uniformity: Exceeds ASTM requirements throughout
the operating range
Integrated timing
KV3000: Seven individual start/stop timers with displays to 0.1 seconds,
accurate to within 0.01%
KV4000: Integrated LCD microcomputer with start/stop buttons and
retention of viscometer tube constants, automatic calculation and
display in viscosity units or seconds to 0.1s, within 0.01% accuracy.
Communication: RS232 port included with KV4000 (optional for KV3000)
Viscometer ports: Seven round 2" (51mm) ports
Bath Medium: Water or suitable heat transfer fluid - please refer to page 8
Bath Construction and Safety Features - Bath chamber is a clear borosilicate
glass vessel enclosed in a polyester-epoxy finished steel housing. Top
working surface has seven 2" (51mm) viscometer ports. Front viewing
window assures safe, distortion-free viewing. Microprocessor temperature
controller incorporates safety circuitry that interrupts power to the heaters in
the event of an overtemperature condition or disconnection of the primary
probe. For added safety, an adjustable redundant controller with separate
sensor probe interrupts power if an overtemperature situation occurs. An
integrated low-liquid sensor prevents operation of the bath if the bath liquid is
not filled to the proper level, and cuts off power should it fall below during
operation. Both overtemperature and low liquid level circuits will latch and
prevent further operation of the bath until the fault is removed.
Dimensions lxwxh,in.(cm)
12" Kinematic Viscosity Bath:
201⁄4x151⁄4x241⁄2 (51x39x62)
Net Weight: 78 lbs (35.5kg)
18" Kinematic Viscosity Bath:
201⁄4x151⁄4x301⁄2 (51x39x77)
Net Weight: 90 lbs (41kg)
Ordering Information
Bath Capacity:
12": 5.8 gal (22L)
18": 8.9 gal (33.7L)
Catalog No.
K23700
K23702
K23790
K23792
K23706
K23708
K23796
K23798
Included Accessories
Port covers, Delrin® (7)
Thermometer holder
≥
Software compatible, inquire
with Koehler Customer Service.
4
Model
KV3000
KV4000
KV3000
KV4000
KV3000
KV4000
KV3000
KV4000
Electrical Requirements
Bath Depth
115V 60Hz, single phase 12.6A
12" (30.5 cm)
220-240V 50/60Hz, single phase 7.2A
115V 60Hz, single phase 12.6A
18" (46 cm)
220-240V 50/60Hz, single phase 7.2A
0-2-11_1a_ViscAA_Layout 1 11/29/12 5:59 PM Page 5
Kinematic Viscosity
KV5000 Kinematic Viscosity Bath
Koehler KV5000 series kinematic viscosity baths with the optical flow
detection system provides automatic viscosity measurements of petroleum
and petrochemical products. Includes communication and power ports for
each optical detection assembly, and can utilize up to five optical assemblies.
Two additional positions are available for manual viscosity measurements, and
all positions can be used in the manual mode. The interchangeable Ubbelohde,
Cannon® Fenske, and Reverse Flow viscometer tubes are quickly installed and
removed from the detection assemblies for cleaning and simple tube changes.
Allows automatic viscosity measurements and results calculation without an
external PC. Motorized stirrer provides complete circulation without turbulence.
Microprocessor PID circuitry assures precise, reliable temperature control
within ASTM specified tolerances throughout the operating range. Simple
push-button controls and dual digital displays permit easy setting and
monitoring of temperature. Two place calibration offset capability is provided.
Built-in cooling coil facilitates temperature control at ambient or below
ambient temperatures.
Viscosity Software
Software automatically downloads test data and calculates final test results
from sample efflux times. Also included is a database for storing test data,
determining test averages, standard deviations, and ASTM test repeatability as
well as providing a method for tracking both instrument and viscometer tube
calibrations.
• Complete instrument and data acquisition system exclusively designed for
conducting D445, IP71 and related test methods
• Optical sensor detection system accurately measures sample flow and
automatically calculates kinematic viscosity results
• Powerful software system for PC platforms operating in Windows®98 SE,
2000, NT, ME, and XP environments
• Option wireless data acquisition package available
• Automatic calculation and display of results in viscosity units or seconds
• Accommodates Ubbelohde, Cannon®Fenske, and Reverse Flow viscometers
• High accuracy temperature control with dual digital displays show setpoint
and actual bath temperature with selectable scale (˚C or ˚F)
• Stand alone feature provides for automated testing without an external PC
• Integrated redundant overtemperature and low liquid level cut-off circuitry
• Software exports test data with graphs and test parameters direct to
Microsoft®Excel or in ASCII file format for use with LIMS or any other
spreadsheet program
• Integrated digital timing for easy measurement of sample efflux times
K23702-OS Kinematic Viscosity Bath (KV5000)
with K23780-CF Optical Sensor and CF Routine Tube 378-025-C02-OS
Specifications
Conforms to the specifications of:
ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550; FTM
791-305; NF T 60-100
Temperature range: Ambient to 150˚C (302˚F); sub-ambient to 10˚C with
external cooling
Temperature display: digital with 0.1 ˚C/˚F resolution, calibrate to 0.01 ˚C/˚F
Temperature control accuracy and uniformity: Exceeds ASTM requirements
Fully Automated Viscosity and Houillon Viscosity Instruments Available,
Inquire with Koehler Customer Service.
Software compatible, inquire
with Koehler Customer Service.
Ordering Information
Catalog No.
Model
K23702-OS
KV5000
K23792-OS
KV5000
K23708-OS
KV5000
K23798-OS
KV5000
K23780-SFW
KV5000
K23780-WLS
KV5000
K23780-CF
378-025-C01-OS
thru 378-700-C01-OS
K23780-RF
378-025-C02-OS
thru 378-700-C02-OS
K23780-UB
378-000-C03-OS
thru 378-005-C03-OS
≥
Description
12" Kinematic Viscosity Bath
12" Kinematic Viscosity Bath
18" Kinematic Viscosity Bath
18" Kinematic Viscosity Bath
Kinematic Viscosity Software Package
Kinematic Visosity Software Package Wireless
Optical Sensor for Cannon®Fenske viscometers
Cannon®Fenske Routine Viscometers Size 25 thru 700
(Specify Size when ordering)
Optical Sensor for Opaque Reverse Flow viscometers
Cannon®Fenske Opaque Viscometers Size 25 thru 700
(Specify Size when ordering)
Optical Sensor for Ubbelohde viscometers
Ubbelohde Viscometers Size 0 thru 5
(Specify Size when ordering)
5
Electrical Requirements
115V 60Hz
220-240V 50/60Hz
115V 60Hz
220-240V 50/60Hz
Order Qty
1
1
1-5
1-5
1-5
1-5
1-5
1-5
0-2-11_1a_ViscAA_Layout 1 11/29/12 5:59 PM Page 6
Kinematic Viscosity
HKV3000 and HKV4000 High Temperature Baths with
Integrated Digital Timing
• Microprocessor temperature control between ambient and 232°C (450°F)
• Integrated digital timing for convenient measurement of sample efflux times
• HKV4000 model permits entry of viscometer constants for automatic
calculation and display in viscosity units or seconds
• Dual digital displays show setpoint and actual bath temperature
• Selectable temperature scale - Fahrenheit or Celsius
• Integrated redundant overtemperature and low liquid level cut-off circuitry
• Conforms to ASTM D445, D2170 and related specifications
High temperature baths with advanced temperature control circuitry and
integrated timing features for convenient, accurate glass capillary viscometry
determinations. Microprocessor PID circuitry assures precise, reliable
temperature control within ASTM specified tolerances throughout the
operating range of the bath. Simple push-button controls and dual digital
displays permit easy setting and monitoring of bath temperature. Two place
calibration offset capability is provided. Baths accommodate seven glass
capillary viscometers of various types - see pages 10-13 for complete
selection of viscometers and holders. Viewing the viscometers is made easy
by glare-free fluorescent illumination inside the bath and a baffle that provides
a background for easy viewing. Temperature control uniformity is assured by
means of motorized stirrer which provides complete circulation without
turbulence. Connection of the built-in cooling coil to tap water or a recirculating
water chiller facilitates temperature control at ambient or below ambient
temperatures. Communications software (RS232, etc.) ramp-to-set, and other
enhanced features are available at additional cost. Contact your Koehler
representative for additional information.
K23802 Digital High Temperature Kinematic Viscosity Bath (HKV4000)
Specifications
Conforms to the specifications of:
ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550;
FTM 791-305; NF T 60-100
Temperature Control
Range: ambient to 232°C (450°F); sub-ambient to 10˚C with
external cooling
Display: 0.1°C/0.1°F resolution, calibrate to 0.01°C/0.01°F
Control accuracy and uniformity: Exceeds ASTM requirements throughout
the operating range
Integrated timing
HKV3000: Seven individual start/stop timers with displays to 0.1s,
accurate to within 0.01%
HKV4000: Integrated LCD microcomputer with start/stop buttons and
retention of viscometer tube constants, automatic calculation and
display in viscosity units or seconds to 0.1s, within 0.01% accuracy.
Communication: RS232 port included with HKV4000 (optional for HKV3000)
Viscometer ports: Seven round 2" (51mm) ports
Bath Medium: water or suitable heat transfer fluid - please refer to page 8
Integrated Timing Features - HKV3000 incorporates seven digital timers on
the front control panel for convenient timing and monitoring of the efflux
interval for each viscometer. On HKV4000, the user can enter the viscosity
constant for each viscometer on the front control/display, and then get the test
result in both efflux time and viscosity units automatically after stopping each
timer. All timing functions are displayed in 0.01 or 0.1 second resolution and
are accurate within 0.01%.
Bath Construction and Safety Features - Bath chamber is a clear borosilicate
glass vessel enclosed in an insulated polyester-epoxy finished steel housing.
Top working surface has seven 2" (51mm) viscometer ports. Front viewing
window assures safe, distortion-free viewing. Microprocessor temperature
controller incorporates safety circuitry that interrupts power to the heaters in
the event of an overtemperature condition or disconnection of the primary
probe. For added safety, an adjustable redundant controller with separate
sensor probe interrupts power if an overtemperature situation occurs. An
integrated low-liquid sensor prevents operation of the bath if the bath liquid is
not filled to the proper level and cuts off power should it fall below during
operation. Both overtemperature and low liquid level circuits will latch and
prevent further operation of the bath until the fault is removed.
Included Accessories
Port covers, Delrin® (7)
Thermometer holder
≥
Software compatible, inquire
with Koehler Customer Service.
Ordering Information
Catalog No. Model
Electrical Requirements
K23800
HKV3000
115V 60Hz, single phase 12.7A
K23802
HKV4000
K23890
K23892
HKV3000
220-240V 50/60Hz, single phase 7.3A
HKV4000
Bath Depth
Bath Capacity
Dimensions lxwxh,in.(cm)
Net Weight
12" (30.5 cm)
5.8 gal (22L)
201⁄4x151⁄4x241⁄2 (51x39x62)
84 lbs (38kg)
6
0-New CatalogPages_Layout 1 11/1/12 2:18 PM Page 1
Kinematic Viscosity
LKV3000 and LKV4000 Refrigerated Constant
Temperature Baths
• Improved design with enhanced performance and safety features
• Standard –30°C (–22°F) LKV3000 model, and extended range –70°C
(–94°F) LKV4000 model
• Microprocessor PID temperature control with two decimal calibration offset
• Dual digital displays show setpoint and actual bath temperature
• Selectable temperature scale - Fahrenheit or Celsius
• Conformity to ASTM D445 and related specifications
Refrigerated constant temperature bath series with improvements in operating
features, safety and cabinetry. Advanced temperature control circuitry includes
microprocessor PID design and two decimal calibration offset. Simple pushbutton controls and dual digital displays permit easy setting and monitoring of
bath temperature. Baths accommodate four glass capillary viscometers using
2" (51mm) round holders (rectangular ports are available on special order) see separate listing on pages 10-13 for complete selection of viscometers and
holders. Bath medium is contained in a clear, evacuated Dewar flask, and
glare-free fluorescent backlighting provides excellent visibility when working
with the viscometers.
Standard and extended range models - Standard LKV3000 model operates
at temperatures from ambient to –30°C (–22°F). Extended range LKV4000
model operates at temperatures as low as –70°C (–94°F). Both models exceed
ASTM temperature control accuracy and uniformity requirements throughout
the operating range. Air-cooled hermetic compressors provide efficient
operation with the use of CFC-free refrigerants.
K22754-OS Digital Refrigerated Kinematic Viscosity Bath
Bath construction and safety features - Insulated steel cabinet has an attractive
polyester-epoxy finish and is mounted on adjustable leveling feet. Chemical
resistant working (top) surface has four round ports for 2" (51mm)
viscometer holders and one port for a thermometer holder. Front viewing
window provides clear, distortion-free visibility.
Included Accessories
Microprocessor controller incorporates circuitry that interrupts power to the
heater in the event of an overtemperature condition or disconnection of the
primary probe. A redundant adjustable controller and sensor probe provide
added overtemperature protection, and an integrated low liquid level sensor
cuts power to the heaters if the bath liquid is not filled to the proper level or
falls below during operation. Both overtemperature and low liquid level circuits
will latch and prevent further operation of the bath until the fault is removed.
Conforms to the specifications of:
ASTM D445, D2532, D6074, D6158; IP 71; ISO 3104; DIN 51550;
FTM 791-305; NF T 60-100
Testing Capacity: Four (4) glass capillary viscometers
Viscometer Ports: Four (4) round 2" (51mm) ports
Bath Dimensions: 91⁄2" dia x 12" deep (24x30cm)
Bath Capacity: 3.7 gal (14L)
Temperature Control:
Display: 0.1°C/0.1°F resolution, calibrate to 0.01°C/0.01°F
Control accuracy and uniformity: Exceeds ASTM requirements throughout
the operating range
Four (4) Delrin® viscometer port covers with handles
Thermometer holder
Specifications
LKV5000 Refrigerated Constant Temperature Baths
with Optical Detection
Koehler LKV5000 series kinematic viscosity baths with the optical flow
detection system provides automatic viscosity measurements of petroleum
and petrochemical products. Includes communication and power ports for
each optical detection assembly, and can utilize up to four optical assemblies.
Optical sensors and viscometer tubes to be ordered separately.
Dimensions lxwxh,in.(cm)
42x35x36 (107x89x91)
Net Weight: 176 lbs (80kg)
≥
Software compatible, inquire
with Koehler Customer Service.
Ordering Information
Catalog No.
K22753
K22753-OS
K22754
K22754-OS
K22751
K22751-OS
K22752
K22752-OS
Model
LKV3000
LKV5000
LKV3000
LKV5000
LKV4000
LKV5000
LKV4000
LKV5000
Temperature Range
15 to -30°C (59 to –22°F)
15 to -30°C (59 to –22°F)
15 to -30°C (59 to –22°F)
15 to -30°C (59 to –22°F)
15 to -70°C (59 to –94°F)
15 to -70°C (59 to –94°F)
15 to -70°C (59 to –94°F)
15 to -70°C (59 to –94°F)
Electrical Requirements
115V 60Hz, Single Phase, 20.1A
115V 60Hz, Single Phase, 20.1A
220-240V 50Hz, Single Phase, 10.6A
220-240V 50Hz, Single Phase, 10.6A
115V 60Hz, Single Phase, 26.9A
115V 60Hz, Single Phase, 26.9A
220-240V 50Hz, Single Phase, 14.5A
220-240V 50Hz, Single Phase, 14.5A
7
Net Weight
176 lbs (80 kg)
176 lbs (80 kg)
176 lbs (80 kg)
176 lbs (80 kg)
176 lbs (80 kg)
176 lbs (80 kg)
176 lbs (80 kg)
176 lbs (80 kg)
Shipping Weight
300 lbs (136 kg)
300 lbs (136 kg)
300 lbs (136 kg)
300 lbs (136 kg)
300 lbs (136 kg)
300 lbs (136 kg)
300 lbs (136 kg)
300 lbs (136 kg)
0-2-11_1a_Visc_Layout 1 10/24/12 10:51 AM Page 8
Kinematic Viscosity
Viscometer Holders
• For use with glass capillary viscometers
Ordering Information
Viscometer Type
Cannon®-Fenske Routine
Cannon®-Fenske Opaque
Cannon®-Manning Semi-Micro
Ubbelohde
Cannon®-Ubbelohde
Cannon®-Ubbelohde Semi-Micro
(Also - Dilution and Semi-Micro Dilution types)
Cross-Arm
BS/IP/RF U-Tube
Cannon®-Manning Vacuum
Asphalt Institute
Modified Koppers
K23382
K23381
Round Holder
Catalog No.
K23381
K23382
K23384
K23383
K23387
K23388
K23384
K23363
Bath Oil
• White mineral oil for routine applications
• Silicone fluid for high temperature applications
High Temperature Viscometer Holders
• For use with HKV baths for temperature up to 232˚C (450˚F)
White Mineral Oil–Highly refined white technical oil for use in constant
temperature baths. Contains an oxidation inhibitor to limit clouding at higher
temperatures. Suitable for use at temperatures of up to 230°F (110°C).
Ordering Information
Viscometer Type
Cannon®-Fenske Routine
Cannon®-Fenske Opaque
Cannon®-Manning Semi-Micro
Ubbelohde
Round Holder
Catalog No.
Silicone Fluid–Clear heat transfer fluid with high oxidation resistance and
low volatility. Recommended for constant temperature bath applications
above 240°F (116°C).
K23381-HT
K23382-HT
Specifications
White Mineral Oil
Silicone Fluid
Nominal Viscosity
14.2-17.0 cSt @ 40°C 100 cSt @ 25°C
Minimum Flash Point
248°F (120°C)
392°F (200°C)
Specific Gravity @ 25°C
0.839-0.855
0.964
Shipped in 1 gal (3.785L) or 5 gal (18.925L) containers
Universal Tube Holders
Can be used interchangeably with Cannon®-Fenske, Cannon®-Manning,
Cross-Arm and Ubbelohde type capillary viscometers. Choice of round (2" dia.)
plastic holders or rectangular metal holders.
Ordering Information
Ordering Information
Catalog No.
K23351
K23350
Catalog No.
355-001-001
355-001-003
355-001-002
355-001-004
Universal Viscometer Holder, Round
Universal Viscometer Holder, Rectangular
Digital Stopwatch
• Accurate to 0.0003%
• Calibration certificate traceable to NIST
Solid-state LCD digital stopwatch with a full range of features, including single
action timing, cumulative split, interval split and more. Housed in a rugged
high impact case with 40" (102cm) lanyard. Supplied with 4-year battery and
calibration certificate traceable to NIST.
Ordering Information
Catalog No.
K23462
Digital Stopwatch
8
White Mineral Oil, 1 Gallon Container
White Mineral Oil, 5 Gallon Container
Silicone Heat Transfer Fluid, 1 Gallon Container
Silicone Heat Transfer Fluid, 5 Gallon Container
0-2-11_1a_Visc_Layout 1 10/24/12 10:51 AM Page 9
Kinematic Viscosity
Viscometer Cleaning and Drying Apparatus
• Six tube capacity
• For all types of capillary viscometers
Cleans and dries glass capillary viscometers using solvent and pressurized
filtered air. Use for all types of kinematic viscometers. Cleans as many as
six tubes at a time. Place tubes on solvent/air jets and open the valve for
each jet. Turn selector dial to ‘solvent’ to rinse tubes, and then to ‘air’ to
evaporate any remaining solvent. Use adjustable drainage rack to drain
excess sample oil from tubes prior to cleaning. Drainage trough connects
to a suitable waste container or chemical drain for removal of waste oil
and solvent. Built-in air filter removes particles from the air stream.
Available solvent tank has tubing with fittings for connection to apparatus.
Requires pressurized air source (150psi maximum).
Dimensions: lxwxh,in.(cm)
without solvent tank
16x7x121/2
(40.6x17.8x31.7)
Net Weight: K34000: 34 lbs (15.4kg)
K34010: 15 lbs (6.8kg)
K34010 Cleaning and Drying Apparatus
Shipping Information:
Shipping Weight:
K34000: 44 lbs (20kg)
K34010: 18 lbs (8.2kg)
Dimensions:
K34000: 8.2 Cu. ft.
K34010: 2.6 Cu. ft.
Ordering Information
Catalog No.
K34000
Viscometer Cleaning and Drying Apparatus
with Solvent Tank
K34010
Viscometer Cleaning and Drying Apparatus
without Solvent Tank
Kinematic Viscosity Thermometers
Catalog
No.
250-000-74F
250-000-74C
250-000-43F
250-000-43C
250-000-73F
250-000-73C
250-000-126F
250-000-126C
250-000-127C
250-000-72F
250-000-72C
250-000-128F
250-000-128C
250-000-44F
250-000-44C
250-000-45F
250-000-45C
250-000-118F
250-000-118C
Test Temperature
IP
Thermometer °F
°C
Reference
ASTM 74F
–65°F
—
69F
ASTM 74C
—
–53.9°C
69C
ASTM 43F –61 to –29°F
—
65F
ASTM 43C
—
–51 to –34°C
65C
ASTM 73F
–40°F
—
68F
ASTM 73C
—
–40°C
68C
ASTM 126F
–15°F
—
71F
ASTM 126C
—
–26°C
71C
ASTM 127C
—
–20°C
99C
ASTM 72F
0°F
—
67F
ASTM 72C
—
–17.8°C
67C
ASTM 128F
32°F
—
33F
ASTM 128C
—
0°C
33C
ASTM 44F
68°F
—
29F
ASTM 44C
—
20°C
29C
ASTM 45F
77°F
—
30F
ASTM 45C
—
25°C
30C
ASTM 118F
86°F
—
—
ASTM 118C
—
30°C
—
Catalog
No.
250-000-28F
250-000-28C
250-000-120C
250-000-46F
250-000-46C
250-000-29F
250-000-29C
250-000-47F
250-000-47C
250-000-48F
250-000-48C
250-000-129F
250-000-129C
250-000-30F
250-000-121C
250-000-110F
250-000-110C
Please note: ASTM D445 recommends calibrated kinematic viscosity thermometers.
Please refer to the ASTM thermometer section on pages 184 through 191.
9
Thermometer
ASTM 28F
ASTM 28C
ASTM 120C
ASTM 46F
ASTM 46C
ASTM 29F
ASTM 29C
ASTM 47F
ASTM 47C
ASTM 48F
ASTM 48C
ASTM 129F
ASTM 129C
ASTM 30F
ASTM 121C
ASTM 11OF
ASTM 110C
Test Temperature
°F
°C
100°F
—
—
37.8°C
—
40°C
122°F
—
—
50°C
130°F
—
—
54.4°C
140°F
—
—
60°C
180°F
—
—
82.2°C
200°F
—
—
93.3°C
210°F
—
—
100°C
275°F
—
—
135°C
IP
Reference
31F
31C
92C
66F
66C
—
34C
35F
35C
90F
90C
36F
36C
32F
32C
—
93C
0-2-11_1a_Visc_Layout 1 10/24/12 10:51 AM Page 10
Kinematic Viscosity
Calibrated Glass Capillary Kinematic Viscometers
Koehler offers a full selection of glass capillary viscometers for measuring
kinematic viscosity of liquid petroleum products in accordance with ASTM
D445 and related standard test methods. All types of viscometers conform to
ASTM D446 and related standard specifications for glass capillary kinematic
viscometers. Each viscometer is supplied with a calibration certificate,
and holders should be ordered separately. Please refer to the following
brief descriptions for determining which viscometer is best suited for your
particular application.
Cannon®-Fenske Routine Viscometers
The Cannon®-Fenske Routine viscometer is a rugged and inexpensive
viscometer that works well if the sample is transparent or translucent. Other
viscometers for transparent samples in this catalog include the Cross Arm and
BS/U-Tube viscometers.
Ubbelohde Viscometers
The Ubbelohde viscometer and other suspended level viscometers are used to
measure transparent liquids. Unlike the Cannon®-Fenske Routine viscometer,
suspended level viscometers maintain the same viscometer constant at all
temperatures, advantageous when samples are to be measured at different
temperatures. Other suspended level viscometers in this catalog include the
BS/IP/SL, BP/IP/SL(S), and BP/IP/MSL viscometers.
Reverse Flow Viscometers
The Cannon®-Fenske Opaque, Cross Arm, and BS/IP/RF U-Tube viscometers
have been designed for testing opaque liquids. These viscometers wet the
timing section of the viscometer capillary only during the actual measurement
and must be cleaned, dried and refilled before a repeat measurement can be
made. By contrast, other viscometer types commonly used to measure
transparent liquids allow the sample to be repeatedly drawn up into the
capillary, permitting duplicate measurements.
Cannon®-Fenske
Routine
Small Volume Viscometers
Cannon®-Fenske
Opaque
Ubbelohde
Cannon®-Fenske Routine
Several semi-micro viscometers have been designed which require one milliliter
or less of liquid, which include the Cannon®-Manning Semi-Micro,
Cannon®-Manning Semi-Micro Extra Low Charge, and Cannon®-Ubbelohde
Semi-Micro viscometers.
For kinematic viscosity of transparent liquids up to 100,000cSt. Requires a
sample of approximately 7mL. Use with K23310 and K23350 rectangular
metal holders or K23381 and K23351 round plastic holders. Length: 250mm
Dilution Viscometers
Catalog No.
378-025-C01
378-050-C01
378-075-C01
378-100-C01
378-150-C01
378-200-C01
378-300-C01
378-350-C01
378-400-C01
378-450-C01
378-500-C01
378-600-C01
378-650-C01
378-700-C01
Estimates of the molecular size and shape of large polymers molecules can be
obtained from kinematic viscosity measurements of dilute solutions. The
Cannon®-Ubbelohde Dilution viscometer has an extra large reservoir which
allows polymer solutions to be diluted several times and measures viscosities
at four different shear rates. Dilute polymer solutions frequently appear to
exhibit changes in kinematic viscosity when the shear rate is changed.
Vacuum Viscometers
In most glass capillary viscometers, the samples flow under gravity. When
liquids are too viscous to flow readily under gravity, vacuum viscometers may be
used to measure viscosity. A vacuum is applied to one end of the viscometer
to pull the liquid through the capillary into the timing bulb. Koehler offers the
Cannon®-Manning Vacuum, the Asphalt Institute Vacuum, and the Modified
Koppers Vacuum reverse flow viscometer tubes. These vacuum viscometers
require an accurately controlled vacuum regulator for proper measurement.
Please refer to page 13 for information about the Koehler Vacuum Regulator.
Size
25
50
75
100
150
200
300
350
400
450
500
600
650
700
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
0.1
0.25
0.5
1.2
2.5
8.0
20.0
45.0
100.0
Kinematic Viscosity
Range, cSt
0.5 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
20 to 100
50 to 250
100 to 500
240 to 1,200
500 to 2,500
1,600 to 8,000
4,000 to 20,000
9,000 to 45,000
20,000 to 100,000
Koehler supplies a wide range of viscosity reference standards used
for calibration and verification of kinematic and dynamic viscosity
test equipment. Please refer to pages 18-19 or contact Koehler
Customer Service for additional information.
10
0-2-11_1a_Visc_Layout 1 10/24/12 10:51 AM Page 11
Kinematic Viscosity
Cannon®-Fenske Opaque
Cannon®-Ubbelohde
Reverse-flow viscometer for measurement of transparent and dark liquids
having kinematic viscosities of up to 100,000cSt. Requires a sample of
approximately 12mL. Allows timing of samples whose thin films are opaque
and are thus not suitable for modified Ostwald and suspended-level type
viscometers. Can be used for kinematic viscosities of asphalts by ASTM
D2170 method. Use with K23310 and K23350 rectangular metal holders or
K23381 and K23351 round plastic holders. Length: 295mm
Suspended level viscometer for transparent liquids. Requires approximately
11mL of sample. Use with K23361 rectangular holder or K23384 round holder.
Length: 335mm
Catalog No.
378-025-C02
378-050-C02
378-075-C02
378-100-C02
378-150-C02
378-200-C02
378-300-C02
378-350-C02
378-400-C02
378-450-C02
378-500-C02
378-600-C02
378-650-C02
378-700-C02
Size
25
50
75
100
150
200
300
350
400
450
500
600
650
700
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
0.1
0.25
0.5
1.2
2.5
8.0
20.0
45.0
100.0
Catalog No.
378-025-C11
378-050-C11
378-075-C11
378-100-C11
378-150-C11
378-200-C11
378-300-C11
378-350-C11
378-400-C11
378-450-C11
378-500-C11
378-600-C11
378-650-C11
378-700-C11
Kinematic Viscosity
Range, cSt
0.4 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
20 to 100
50 to 250
100 to 500
240 to 1,200
500 to 2,500
1,600 to 8,000
4,000 to 20,000
9,000 to 45,000
20,000 to 100,000
Approximate
Constant, cSt/s
0.001
0.003
0.005
0.01
0.03
0.05
0.1
0.3
0.5
1.0
3.0
5.0
10.0
30.0
50.0
100.0
Catalog No.
378-025-C15
378-050-C15
378-075-C15
378-100-C15
378-150-C15
378-200-C15
378-300-C15
378-350-C15
378-400-C15
378-450-C15
378-500-C15
378-600-C15
Kinematic Viscosity
Range, cSt
0.3 to 1
0.6 to 3
1 to 5
2 to 10
6 to 30
10 to 50
20 to 100
60 to 300
100 to 500
200 to 1,000
600 to 3,000
1,000 to 5,000
2,000 to 10,000
6,000 to 30,000
10,000 to 50,000
20,000 to 100,000
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
0.1
0.25
0.5
1.2
2.5
8.0
20.0
Kinematic Viscosity
Range, cSt
0.5 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
20 to 100
50 to 200
100 to 500
240 to 1,200
500 to 2,500
1,600 to 8,000
4,000 to 20,000
For transparent liquids. Requires approximately 1.0mL of sample. Use with
K23361 rectangular holder or K23384 round holder. Length: 335mm
Catalog No.
378-025-C12
378-050-C12
378-075-C12
378-100-C12
378-150-C12
378-200-C12
378-300-C12
378-350-C12
378-400-C12
378-450-C12
378-500-C12
378-600-C12
Suspended level viscometer for the measurement of intrinsic viscosity
extrapolated to zero shear rate. Provides five-fold range of shear rates.
Requires approximately 20mL of sample. Use with K23361 rectangular
holder or K23384 round holder. Length: 280 mm
Size
25
50
75
100
150
Size
25
50
75
100
150
200
300
350
400
450
500
600
Cannon®-Ubbelohde Semi-Micro
Cannon®-Ubbelohde Four-Bulb Shear Dilution
Catalog No.
378-025-C16
378-050-C16
378-075-C16
378-100-C16
378-150-C16
Kinematic Viscosity
Range, cSt
0.5 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
20 to 100
50 to 200
100 to 500
240 to 1,200
500 to 2,500
1,600 to 8,000
4,000 to 20,000
9,000 to 45,000
20,000 to 100,000
Suspended level viscometer for the measurement of intrinsic viscosity of
transparent liquids. Requires approximately 8mL of sample. Use with K23361
rectangular holder or K23384 round holder. Length: 385mm. Note: 18" Depth
bath required to accommodate tubes.
Suspended-level type viscometer for kinematic viscosities of transparent
liquids of up to 100,000cSt. Requires a sample volume of approximately
11mL. Use with K23320 and K23350 rectangular metal holders or K23382
and K23351 round plastic holders. Length: 283mm
Size
0
0C
0B
1
1C
1B
2
2C
2B
3
3C
3B
4
4C
4B
5
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
0.1
0.25
0.5
1.2
2.5
8.0
20.0
45.0
100.0
Cannon®-Ubbelohde Dilution
Ubbelohde
Catalog No.
378-000-C03
378-00C-C03
378-00B-C03
378-001-C03
378-01C-C03
378-01B-C03
378-002-C03
378-02C-C03
378-02B-C03
378-003-C03
378-03C-C03
378-03B-C03
378-004-C03
378-04C-C03
378-04B-C03
378-005-C03
Size
25
50
75
100
150
200
300
350
400
450
500
600
650
700
Kinematic Viscosity
Range, cSt
0.5 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
11
Size
25
50
75
100
150
200
300
350
400
450
500
600
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
0.1
0.25
0.5
1.2
2.5
8.0
20.0
Kinematic Viscosity
Range, cSt
0.5 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
20 to 100
50 to 200
100 to 500
240 to 1,200
500 to 2,500
1,600 to 8,000
4,000 to 20,000
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 12
Kinematic Viscosity
Cannon®-Manning Semi-Micro
BS/IP/RF U-Tube Opaque
For transparent liquids. Requires a sample of approximately 1.0mL. Use with
K23310 and K23350 rectangular holders or K23381 and K23351 round holders.
Length: 275mm
Reverse-flow viscometer for opaque liquids having kinematic viscosities of up
to 300,000cSt. Requires a sample of 12-25mL. Use with K23330 rectangular
metal holders or K23387 round plastic holders. Length: 275mm
Catalog No.
378-025-C10
378-050-C10
378-075-C10
378-100-C10
378-150-C10
378-200-C10
378-300-C10
378-350-C10
378-400-C10
378-450-C10
378-500-C10
378-600-C10
Size
25
50
75
100
150
200
300
350
400
450
500
600
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
0.1
0.25
0.5
1.2
2.5
8.0
20.0
Kinematic Viscosity
Range, cSt
0.5 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
20 to 100
50 to 200
100 to 500
240 to 1,200
500 to 2,500
1,600 to 8,000
4,000 to 20,000
Catalog No.
378-001-C08
378-002-C08
378-003-C08
378-004-C08
378-005-C08
378-006-C08
378-007-C08
378-008-C08
378-009-C08
378-010-C08
378-011-C08
Size
1
2
3
4
5
6
7
8
9
10
11
Approximate
Constant, cSt/s
0.003
0.01
0.03
0.1
0.3
1.0
3.0
10.0
30.0
100.0
300.0
Kinematic Viscosity
Range, cSt
0.6 to 3
2 to 10
6 to 30
20 to 100
60 to 300
200 to 1,000
600 to 3,000
2,000 to 10,000
6,000 to 30,000
20,000 to 100,000
60,000 to 300,000
Cannon®-Manning Semi-Micro Extra Low Charge
BS/U-Tube Transparent
For transparent liquids. Requires a sample of approximately 0.5mL. Use with
K23350 rectangular holders or K23351 round holders. Length: 200mm
U-Tube viscometer for transparent liquids having kinematic viscosities of up to
10,000cSt. Requires a sample of 7-23mL. Length: 300mm
Catalog No.
378-025-C17
378-050-C17
378-075-C17
378-100-C17
378-150-C17
378-200-C17
378-300-C17
378-350-C17
378-400-C17
378-450-C17
378-500-C17
378-600-C17
Size
25
50
75
100
150
200
300
350
400
450
500
600
Approximate
Constant, cSt/s
0.002
0.004
0.008
0.015
0.035
0.1
0.25
0.5
1.2
2.5
8.0
20.0
Kinematic Viscosity
Range, cSt
0.5 to 2
0.8 to 4
1.6 to 8
3 to 15
7 to 35
20 to 100
50 to 200
100 to 500
240 to 1,200
500 to 2,500
1,600 to 8,000
4,000 to 20,000
Catalog No.
378-00A-C08
378-00B-C08
378-00C-C08
378-00D-C08
378-00E-C08
378-00F-C08
378-00G-C08
378-00H-C08
Approximate
Constant, cSt/s
0.003
0.01
0.03
0.1
0.3
1.0
3.0
10.0
30.0
100.0
Kinematic Viscosity
Range, cSt
0.9 to 3
2.0 to 10
6 to 30
20 to 100
60 to 300
200 to 1,000
600 to 3,000
2,000 to 10,000
Miniature U-Tube viscometer for transparent liquids having kinematic
viscosities of up to 100cSt. Requires a sample of 2mL. Length: 250mm
Reverse-flow type viscometer for transparent and dark liquids having
kinematic viscosities of up to 100,000cSt. Requires a sample of approximately
1-3mL. Use with K23362 and K23350 rectangular metal holders or K23383
and K23351 round plastic holders. Length: 305mm
Size
1
2
3
4
5
6
7
8
9
10
Approximate
Constant, cSt/s
0.003
0.01
0.03
0.1
0.3
1.0
3.0
10.0
BS/U/M Miniature U-Tube
Cross-Arm
Catalog No.
378-001-C09
378-002-C09
378-003-C09
378-004-C09
378-005-C09
378-006-C09
378-007-C09
378-008-C09
378-009-C09
378-010-C09
Size
A
B
C
D
E
F
G
H
Catalog No.
378-0M1-C18
378-0M2-C18
378-0M3-C18
378-0M4-C18
378-0M5-C18
Kinematic Viscosity
Range, cSt
0.6 to 3
2 to 10
6 to 30
20 to 100
60 to 300
200 to 1,000
600 to 3,000
2,000 to 10,000
6,000 to 30,000
20,000 to 100,000
Size
M1
M2
M3
M4
M5
Approximate
Constant, cSt/s
0.001
0.005
0.015
0.04
0.1
Kinematic Viscosity
Range, cSt
0.2 to 1
1 to 5
3 to 15
8 to 40
20 to 100
Vacuum Manifold
Designed for use with Koehler capillary-type viscometer tube baths and
vacuum regulator. Manifold includes seven position valves and tubing for
applying vacuum or pressure as per ASTM D2171.
Ordering Information
Catalog No.
K23467
Koehler supplies a wide range of viscosity reference standards used
for calibration and verification of kinematic and dynamic viscosity
test equipment. Please refer to pages 18-19 or contact Koehler
Customer Service for additional information.
12
Vacuum Manifold
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 13
Kinematic Viscosity
BS/IP/MSL Miniature Suspended Level
Cannon®-Manning Vacuum
Miniature suspended level viscometer for transparent liquids having
kinematic viscosities of up to 3,000cSt. Requires a sample of 4mL.
Length: 345mm
For highly viscous materials, including asphalt cement at 140°F (60°C) in
accordance with ASTM D2171. Requires approximately 6mL of sample. Use
with K23360 rectangular holder or K23388 round holder. Length: 230-260mm
Catalog No.
378-001-C19
378-002-C19
378-003-C19
378-004-C19
378-005-C19
378-006-C19
378-007-C19
Size
1
2
3
4
5
6
7
Approximate
Constant, cSt/s
0.003
0.01
0.03
0.1
0.3
1.0
3.0
Kinematic Viscosity
Range, cSt
0.6 to 3
2 to 10
6 to 30
20 to 100
60 to 300
200 to 1,000
600 to 3,000
Catalog No.
378-004-C13
378-005-C13
378-006-C13
378-007-C13
378-008-C13
378-009-C13
378-010-C13
378-011-C13
378-012-C13
378-013-C13
378-014-C13
BS/IP/SL Suspended Level
Suspended level viscometer for transparent liquids having kinematic
viscosities of up to 100,000cSt. Requires a sample of 11mL. Length: 250mm
Catalog No.
378-001-C20
378-01A-C20
378-002-C20
378-02A-C20
378-003-C20
378-03A-C20
378-004-C20
378-04A-C20
378-005-C20
Size
1
1A
2
2A
3
3A
4
4A
5
Approximate
Constant, cSt/s
0.01
0.03
0.1
0.3
1.0
3.0
10.0
30.0
100.0
Kinematic Viscosity
Range, cSt
3.5 to 10
6 to 30
20 to 100
60 to 300
200 to 1,000
600 to 3,000
2,000 to 10,000
6,000 to 30,000
20,000 to 100,000
Asphalt Institute Vacuum
Similar to Cannon®-Manning Vacuum type, but with graduated capillary
instead of two timing bulbs. Requires a sample of approximately 4mL. Use
with K23360 rectangular holder or K23388 round holder. Length: 230-260mm
Approximate Constant at 300mm Hg
vacuum, poise/second
Catalog No.
378-025-C14
378-050-C14
378-100-C14
378-200-C14
378-400-C14
BS/IP/SL(S) Suspended Level
Shortened suspended level viscometer for transparent liquids having
kinematic viscosities of up to 100,000cSt. Requires a sample of 10mL.
Length: 255mm
Catalog No.
378-001-C21
378-002-C21
378-003-C21
378-004-C21
378-005-C21
378-006-C21
378-007-C21
378-008-C21
378-009-C21
Size
1
2
3
4
5
6
7
8
9
Approximate
Constant, cSt/s
0.0008
0.003
0.01
0.03
0.1
0.3
1.0
3.0
10.0
Approximate Constant at 300mm Hg
vacuum, poise/second
Viscosity
Size
Bulb B
Bulb C
Range, Poise
4
0.0002
0.0006
0.36 to 0.8
5
0.006
0.002
0.12 to 2.4
6
0.02
0.006
0.36 to 8
7
0.06
0.02
1.2 to 24
8
0.2
0.06
3.6 to 80
9
0.6
0.2
12 to 240
10
2
0.6
36 to 800
11
6
2
120 to 2,400
12
20
6
360 to 8,000
13
60
20
1,200 to 24,000
14
200
60
3,600 to 80,000
Size
25
50
100
200
400
Bulb B
2
8
32
128
500
Bulb C
1
4
16
64
250
Viscosity
Bulb D Range, Poise
0.7
42 to 800
3
180 to 3,200
10
600 to 12,800
40 2,400 to 52,000
160 9,600 to 200,000
Modified Koppers Vacuum
For highly viscous materials in accordance with ASTM D2171. Requires a
sample of 2mL. Use with K23364 rectangular holder or K23363 round holder.
Length: 270mm
Kinematic Viscosity
Range, cSt
3.5 to 10
6 to 30
20 to 100
60 to 300
200 to 1,000
600 to 3,000
2,000 to 10,000
6,000 to 30,000
20,000 to 100,000
Approximate Constant at 300mm Hg
vacuum, poise/second
Catalog No.
378-025-C06
378-050-C06
378-100-C06
378-200-C06
378-400-C06
Size
25
50
100
200
400
Bulb B
2
8
32
128
500
Bulb C
1
4
16
64
250
Viscosity
Bulb D Range, Poise
0.7
42 to 800
3
180 to 3,200
10
600 to 12,800
40 2,400 to 52,000
160 9,600 to 200,000
Vacuum Regulator
Vacuum Regulator
For ASTM D2171, “Viscosity of Asphalts by Vacuum Capillary Viscometers.”
Precisely controls vacuum from 28 to 411 mm Hg below atmospheric
pressure to an accuracy of ±0.5 mm Hg. Recommended for use with
Cannon®-Manning, Asphalt Institute or Modified Koppers vacuum
viscometers. All solid-state—contains no mercury. Amount of vacuum is
shown on digital display. Ten different units of vacuum measurement may
be selected through keypad on the meter.
Ordering Information
Catalog No.
K23463
K23464
K23465
K23466
13
Vacuum Regulator (vertical orientation), 115V 60Hz
Vacuum Regulator (vertical orientation), 220-240V 50/60Hz
Vacuum Regulator (horizontal orientation), 115V 60Hz
Vacuum Regulator (horizontal orientation), 220-240V 50/60Hz
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 14
Low Temperature Viscosity Measured by Rotational Viscometer
Test Method
Determines the low temperature, low shear rate viscosities of gear oils,
automatic transmission fluids, hydraulic oils and other fluid lubricants by
use of a rotational viscometer.
New BVS4000 Brookfield Viscosity Air Bath System
•
•
•
•
Conforms to ASTM D2983 and related specifications
Mechanically refrigerated with digital indicating temperature control
Operating range to –50°C
Sixteen sample capacity
Mechanically refrigerated cold cabinet prepares samples for dynamic viscosity
determinations on petroleum lubricants. A built-in turntable rotates the samples
at 4rpm per specifications. Cooling system maintains cabinet temperature
within ±0.1°C at temperatures as low as –50°C. Cabinet temperature is
displayed in digital format on the front panel. Cabinet accommodates sixteen
(16) sample cells with cell carriers. Includes insulated cover.
Specifications
K34702 Brookfield Viscosity Air Bath System (BVS4000)
New BVS3000 Brookfield Viscosity Liquid Bath System
•
•
•
•
Permits viscosity measurements without the risk of temperature increase
10 sample turntable
Mechanically refrigerated with digital indicating temperature control
Operating range to –55°C
Constant temperature liquid bath permits testing of samples without the risk
of sample temperature rise. After cooling in the air bath, the sample must be
transferred to the balsa cell carrier for testing with the Rotational viscometer.
If the sample is not tested quickly, there is the risk of sample temperature rise.
The Brookfield Viscosity Liquid Bath System eliminates this risk by permitting
the sample to be tested in a constant temperature environment. The Rotational
viscometer mounts directly on the bath and the samples are rotated into
position under the spindle by means of a built-in turntable. Cooling system
maintains temperature with ±0.05°C stability in the range of +10°C to –55°C.
Bath temperature is displayed in digital format.
Conforms to the specifications of:
ASTM D2983; IP 267 Method A; ISO 9262; CEC-L-18A
Capacity: 16 sample cells with cell carriers
Temperature Range: +10°C to –50°C
Temperature control accuracy: ± 0.1°C
Sample Rotation: 4rpm
Electrical Requirements:
115V 60Hz, Single Phase, 16A
220-240V 50 or 60Hz, Single Phase, 12A
Dimensions: lxwxh,in.(cm)
36x28x43 (91x71x109)
Net Weight: 315 lbs (143kg)
Shipping Information
Shipping Weight: 380 lbs (172kg)
Dimensions: 38.9 Cu. ft.
Ordering Information
Catalog No.
K34710
K34711
K34712
Specifications
Conforms to the specifications of: ASTM D2983
Sample Capacity: 10 samples
Temperature Range: +10°C to –55°C
Temperature Control Stability: ±0.05°C
Electrical Requirements:
115V 60Hz, Single Phase, 16A
220-240V 50 or 60Hz, Single Phase, 12A
Dimensions: lxwxh,in.(cm)
Shipping Information
17x24x25(43x61x25)
Net Weight: 265 lbs (120kg)
Shipping Weight: 300 lbs (136kg)
Dimensions: 13.9 Cu. ft.
K34700
K34701
K34702
≥
BVS3000 Brookfield Viscosity Liquid Bath System
115V 60Hz
BVS3000 Brookfield Viscosity Liquid Bath System
220-240V 50Hz
BVS3000 Brookfield Viscosity Liquid Bath System
220-240V 60Hz
BVS4000 Brookfield Viscosity Air Bath System
115V 60Hz
BVS4000 Brookfield Viscosity Air Bath System
220-240V 50Hz
BVS4000 Brookfield Viscosity Air Bath System
220-240V 60Hz
Software compatible, inquire
with Koehler Customer Service.
14
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 15
Low Temperature Viscosity Measured by Rotational Viscometer
BVS5000 Programmable Brookfield Viscosity
Liquid Bath System
• Sample soaking and testing in a single bath, eliminating the need for an
air bath and the risk of sample temperature rise during transfer
• Redesigned for improved control of sample movement and handling
during testing
• Microprocessor PID temperature control duplicates the sample cooling
rates in ASTM D2983
• Up to 40 cooling/testing temperature profiles can be stored in memory
Redesigned programmable baths with improved features for sample handling
and testing. Bath accommodates 10 samples for Dynamic Viscosity testing.
Sample cells are immersed in a liquid bath for the entire soaking and testing
period, eliminating the need to transfer cells from an air bath to a liquid bath
with insulated balsa wood carriers. Also eliminated is the inherent risk of
sample temperature rise during transfer. The programmable microprocessor
PID controller stores up to 40 temperature profiles that duplicate the sample
cooling rates found in ASTM D2983. Steady state temperature accuracy and
uniformity exceed ASTM requirements throughout the operating range from
ambient to -55°C. Air-cooled hermetic compressors provide efficient operation
with the use of CFC-free refrigerants.
The mounting position for the Rotational Viscometer has been changed to
permit easier access to the samples and viscometer controls. Cabinet has a
front window and glare-free fluorescent lighting for distortion free viewing of
the sample cells. Cabinet construction is polyester-epoxy finished steel with a
chemical-resistant composite top surface. A removable insulated cover with
handle is included. Bath rests on adjustable leveling feet. Safety features
include a probe fault detection circuit in the primary temperature controller and
a redundant latching controller and probe for temperature fault protection.
Specifications
Conforms to the specifications of:
ASTM D2983 - Note 2 and Note 10; IP 267 Method B; CEC-L-18A-30;
ISO 9262
Sample capacity: 10 samples
Temperature control: Microprocessor PID digital-indicating programmable
controller with ±0.05°C steady state stability
Operating Range: ambient to –55°C
Electrical Requirements:
220-240V 50 or 60Hz, Single Phase, 12.6A
K34715 Programmable Brookfield Viscosity Liquid Bath System
Accessories
Catalog No.
K447-BL
K447-PL
Shipping Information
K34706
K447-SP-L4
K2983-2
K34707
K34779
K34708
K34709
K34770
250-000-122C
Shipping Weight: 497 lbs (226kg)
Dimensions: 41.5 Cu. ft.
250-000-123C
Dimensions: lxwxh,in.(cm)
41x34x38 (104x86.5x96.5)
Net Weight: 327 lbs (148.5kg)
250-000-124C
Ordering Information
Catalog No.
K34715
K34716
BVS5000 Programmable Brookfield Viscosity
Liquid Bath System, 220-240V 50Hz
BVS5000 Programmable Brookfield Viscosity
Liquid Bath System, 220-240V 60Hz
250-000-125C
355-005-027
355-005-115
≥
Software compatible, inquire
with Koehler Customer Service.
15
Order Qty
Rotational Viscometer, Bold Series L
1
100-240V 50/60Hz
Rotational Viscometer, Power Series L
1
100-240V 50/60Hz
Insulated Spindle No.4B2
1
L4 Spindle
1
Cell Stopper (For K34706 Only)
1
Cell Stopper
12
Spindle Support Clips
12
Insulated Cell Carrier (for Air Bath)
1
Test Cell - Round Bottom (pack of 12)
1
Test Cell - Flat Bottom (pack of 12)
1
ASTM 122C/IP94C Thermometer
1
Range –45 to –35°C
ASTM 123C/IP95C Thermometer
1
Range –35 to –25°C
ASTM 124C/IP96C Thermometer
1
Range –25 to –15°C
ASTM 125C/IP97C Thermometer
1
Range –15 to –5°C
Viscosity Standard N27B
1
Viscosities in centipoise at –40, –30, –20, –15, –10, 0°F
Viscosity Standard N115B
1
Viscosity in centipoise at –20, –15, –10, 0, +10, 20°F
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 16
Saybolt Viscosity
Test Method
Determines the time required for 60mL of sample to flow through a calibrated
orifice under precisely controlled conditions. Saybolt Universal Seconds (SUS) is
the standard measurement for lubricants, insulating oils and lighter fuel grades,
and Saybolt Furol Seconds (SFS) is used for heavier oils and bitumens.
SV3000 Saybolt Viscosity Bath and
New SV4000 Saybolt Viscosity Bath
for Automatic Viscosity Timing
•
•
•
•
•
•
Microprocessor control of temperature between ambient and 240°C (464°F)
Four tube capacity
Dual digital displays show setpoint and actual temperature
Selectable temperature scale - Celsius or Fahrenheit
Automatic timing option for simplified, accurate measurement of efflux times
Conforms to ASTM D88, D244, E102, and related specifications
Constant temperature bath with available automatic timing feature for viscosity
determinations using Saybolt viscometer tubes and orifices. Microprocessor
PID circuitry assures precise temperature control within ASTM specified
tolerances throughout the operating range of the bath. Simple push-button
controls and dual digital displays permit easy setting and monitoring of bath
temperature. Two place calibration offset is provided. Accommodates four
viscometers and four 60mL receiving flasks. Sliding draft shields and a
chemical-resistant alignment plate facilitate handling of the flasks, and
glare-free fluorescent backlighting is provided for easy viewing of the samples.
Communications software (RS232, etc.) ramp-to-set, and other enhanced
features are available at additional cost. Contact your Koehler representative
for additional information.
Automatic Timing Option – At the push of a button, the automatic timer starts
the sample flow, senses the 60mL end point, and digitally records and displays
the efflux time in 0.1 seconds resolution with an accuracy of 0.05%.
Automatic timing improves testing accuracy and convenience, eliminating the
chain and cork assembly and the need to manually time each sample. Timer
installation is available in any configuration from 1 to 4 positions.
K21414 Saybolt Viscosity Bath (SV4000) with K21404 Auto Viscosity Timers
Ordering Information
Catalog No.
Order Qty
SV3000 Saybolt Viscosity Bath
K21410
SV3000 Saybolt Viscosity Bath, 115V 60Hz
1
K21420
SV3000 Saybolt Viscosity Bath, 220-240V 50/60Hz
SV4000 Saybolt Viscosity Bath for Automatic Viscosity Timing
K21414
SV4000 Saybolt Viscosity Bath, 115V 60Hz
1
K21424
SV4000 Saybolt Viscosity Bath, 220-240V 50/60Hz
Automatic Saybolt Viscosity Timing Sensor
K21404
Automatic Saybolt Viscosity Timing Sensor,
1-4
115V 60Hz
K21494
Automatic Saybolt Viscosity Timing Sensor,
1-4
220-240V 50/60Hz
Bath Construction and Safety Features – Insulated bath interior is constructed
entirely of heavy gauge stainless steel. A built-in overflow pipe and drain valve
simplifies filling of the bath fluid to the proper level. Chemical resistant top
plate provides excellent insulation and is easily removed to allow for cleaning
of the bath interior. A cooling coil for tap water or refrigerated coolant is
provided for operation at near-ambient temperatures. Steel cabinet has
leveling feet and a chemical resistant polyurethane-epoxy finish.
Specifications
Conforms to the specifications of:
ASTM D88, D244, E102; AASHTO T72; FTM 791-304
Capacity: 4 viscometer tubes
Temperature Range: ambient to 464°F (240°C)
Temperature Stability: ±0.05°F (±0.03°C)
Bath Capacity: 5 gal (19L)
Recommended Bath Medium: water or suitable heat transfer fluid
Electrical Requirements:
115V 60Hz, single phase, 12.3A
220-240V 50/60Hz, single phase, 6.4A
Included Accessories
Dimensions lxwxh,in.(cm)
x
29x25x33 (74x631⁄2x84)
Cleaning Plunger Chained Corks
Net
Weight: 65 lbs (291⁄2kg)
Oil Strainer
Withdrawal Tube
Tube Nut Wrench Orifice Wrench
Shipping Information
Port Closures
Port Covers
Shipping Weight: 82 lbs (37kg)
Thermometer Supports
Dimensions: 10 Cu. ft.
Each port can accommodate one sensor for automatic timing
operation on SV4000 Saybolt Viscosity Baths.
Accessories
355-001-002
355-001-004
Silicone Heat Transfer Fluid, 1 Gallon Container
Silicone Heat Transfer Fluid, 5 Gallon Container
minimum flash point 620°F (326°C)
5
1
Please refer to separate listing on page 8 for specifications.
Please contact Koehler Customer Service about the retrofitting of
SV3000 Series Saybolt Viscosity Baths with the new K21404
Automatic Saybolt Viscosity Timing Sensors.
≥
Software compatible, inquire
with Koehler Customer Service.
16
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 17
Saybolt Viscosity
Orifices–Stainless Steel Universal and Furol Orifices meeting ASTM
specifications. Orifices insert in viscometer tubes using K22030 Orifice
Wrench (supplied with viscometer baths). Also available - Kansas Road
Oil Orifice (requires K22039 wrench). Universal and Furol Orifices are
available with a calibration certificate.
Saybolt Viscometer Tubes and Orifices
• Conforming to ASTM D88, E102 and related specifications
• Choice of brass or stainless steel tubes
Viscometer Tubes–Precisely machined brass and stainless steel tubes
meeting ASTM requirements. Tubes mount vertically in Saybolt
Viscometer Baths and accommodate stainless steel orifices interchangeably.
Supplied with mounting hardware.
Ordering Information
Catalog No.
Viscometer Tubes
K22009
Saybolt Viscometer Tube, Brass
K22309
Saybolt Viscometer Tube, Stainless Steel
Orifices
K22010
Saybolt Universal Orifice
K22010-C/F
Saybolt Universal Orifice with calibration certificate
K22020
Furol Orifice
K22020-C/F
Saybolt Furol Orifice with calibration certificate
K22029
Kansas Road Oil Orifice
K22009
Accessories
332-003-003
332-003-014
K22030
K22039
K22050
K22060
K22070
K22080
K22010
K22090
K22011
Borosilicate Glass Receiving Flask, 60mL for SV3000
Borosilicate Glass Receiving Flask, 60mL for SV4000
Orifice Wrench for Universal and Furol Orifices
Orifice Wrench for Kansas Road Oil Orifices
Socket Wrench
Oil Strainer
Cleaning Plunger
Displacement Ring. Insert in viscometer tube galley
for bituminous materials testing.
Meets ASTM E102 specifications.
Withdrawal Tube
Thermometer Support
Saybolt Viscosity Thermometers
Catalog
Number
Thermometer
250-000-17F
250-000-17C
250-000-18F
250-000-18C
250-000-19F
250-000-19C
250-000-20F
250-000-20C
250-000-21F
250-000-21C
ASTM 17F
ASTM 17C
ASTM 18F
ASTM 18C
ASTM 19F
ASTM 19C
ASTM 20F
ASTM 20C
ASTM 21F
ASTM 21C
Test Temperature
°F
°C
Range
66 to 80°F
—
66 to 80°F
—
19 to 27°C
19 to 27°C
100°F
—
94 to 108°F
—
34 to 42°C
34 to 42°C
122 and 130°F
—
120 to 134°F
—
50 and 54.4°C 49 to 57°C
140°F
—
134 to 148°F
—
60°C
57 to 65°C
180°F
—
174 to 188°F
—
82.2°C
79 to 87°C
Catalog
Number
Thermometer
Test Temperature
°F
°C
250-000-22F
250-000-22C
250-000-77F
250-000-108F
250-000-78F
250-000-109F
250-000-79F
250-000-80F
250-000-81F
ASTM 22F
ASTM 22C
ASTM 77F
ASTM 108F
ASTM 78F
ASTM 109F
ASTM 79F
ASTM 80F
ASTM 81F
210°F
—
250°F
275°F
300°F
325°F
350°F
400°F
450°F
—
98.9°C
121°C
135°C
149°C
163°C
177°C
204°C
232°C
Range
204 to 218°F
95 to 103°C
245 to 265°F
270 to 290°F
295 to 315°F
320 to 340°F
345 to 365°F
395 to 415°F
445 to 465°F
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Test apparatus for lubricants, insulating oils, and heater fuel grades:
Catalog No.
Order Qty
K21410
Saybolt Viscometer Bath
1
K22009
Viscometer Tube
4
K22010
Universal Orifice
4
332-003-003 ReceivIng Flask (SV3000)
4
332-003-014 Borosilicate Glass Receiving Flask, 60mL for SV4000
355-001-001 White Technical Oil
5
250-000-17F Series ASTM Thermometers or
250-000-17C Series ASTM Thermometers
Test apparatus for bituminous materials:
Catalog No.
Order Qty
K21410
Saybolt Viscometer Bath
1
K22009
Viscometer Tube
4
K22020
Furol Orifice
4
K22080
Displacement Ring
4
332-003-003 Receiving Flask (SV3000)
4
332-003-014 Borosilicate GlassReceiving Flask, 60mL for SV4000
355-001-002 High Temperature Heat Transfer Fluid
5
250-000-17F Series ASTM Thermometers or
250-000-17C Series ASTM Thermometers
17
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 18
Viscosity Standards
Viscosity Reference Standards
• Manufactured and certified according to ASTM D2162, the primary
method for viscosity reference standards
• Supplied with an ISO/IEC 17025 Certification Report
• Fully compliant to ASTM and related test procedures
• Custom standards available
Koehler viscosity reference standards are used for calibration and verification
of kinematic and dynamic viscosity test equipment, both manual and
automatic. All viscosity standards are based upon the National Institute of
Standards and Technology (NIST) value of 1.0034 cSt (Centistokes) for water
at 20°C (68°F). All standards are traceable to National Standards and are
manufactured and certified according to ASTM D2162, the internationally
recognized primary method for viscosity reference standards, under ISO/IEC
17025 guidelines. Standards are calibrated to a precision of ±0.2% for the
viscosity and kinematic viscosity. Nominal or approximate values are listed in
the following tables. With each standard, actual certified values for kinematic
viscosity (cSt), dynamic viscosity (cP), and density (g/mL) according to ASTM
D1480 are provided at each temperature point of calibration along with
uncertainty measurements. Each standard is calibrated at a minimum of five
temperatures and supplied in a 500mL quantity in an amber-colored bottle
complete with full certification and a Material Data Safety Sheet (MSDS).
In addition to the many viscosity standards described in this catalog, we can
supply custom viscosity standards made specifically to meet your individual
needs including high volume supply used for Statistical Quality Check and
Statistical Process Control (SQC/SPC) applications.
Viscosity Reference Standards
Viscosity Standards Conforming to ASTM Standards
Catalog
No.
355-004-004
355-004-008
355-004-001
355-002-003
355-003-005
355-002-006
355-003-010
355-004-010
355-002-020
355-004-035
355-002-060
355-004-100
355-002-200
355-003-500
355-004-350
355-003-103
355-002-600
355-004-103
355-002-203
355-003-503
355-003-752
355-004-403
355-002-803
355-004-153
355-002-304
Viscosity
Standard
N.4
N.8
N1.0
S3
D5
S6
D10
N10
S20
N35
S60
N100
S200
D500
N350
D1000
S600
N1000
S2000
D5000
D7500
N4000
S8000
N15000
S30000
20°C
68°F
0.47
0.95
1.3
4.6
7.0
10
14
21
43
77
165
372
672
825
1,255
1,689
2,184
4,678
8,323
8,800
13,296
17,889
34,931
79,423
—
Approximate Kinematic Viscosity in mm2/s (Centistokes)
25°C
37.8°C
40°C
50°C
60°C
77°F
100°F
104°F
122°F
140°F
0.45
0.41
0.40
—
—
0.89
0.77
0.75
—
—
1.2
1.0
0.97
—
—
4.0
3.0
2.9
2.4
—
6.1
—
4.2
3.4
—
8.7
6.0
5.7
4.5
—
12
8.0
7.5
5.8
—
17
11
10
7.3
—
34
20
18
13
—
59
35
29
20
—
121
60
54
35
—
268
128
114
70
—
468
200
181
107
—
578
—
226
133
—
865
371
324
186
—
1,151
—
418
236
—
1,472
600
518
286
—
3,089
—
1020
542
350
5,422
2,000
1,719
889
—
5,700
2,150
1,850
950
—
8,609
2,681
—
1,365
—
11,470
—
3,448
1,720
850
22,383
8,000
6,710
3,317
—
49,714
—
13,994
6,650
3,000
84,687
28,079
23,570
11,058
—
18
98.9°C
210°F
—
—
—
1.2
—
1.9
2.3
2.7
4.0
5.3
7.7
13
18
—
28
—
37
—
87
—
—
—
—
—
—
100°C
212°F
—
—
—
1.2
1.5
1.9
2.3
2.7
3.9
5.2
7.5
13
17
21
27
32
36
57
83.3
88
118
137
242
406
628
Saybolt Viscosity
SUS
SUS
SFS
100°F
210°F
122°F
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
96.6
—
—
152.1
—
—
281
—
—
592
—
—
955
88.2
—
—
—
—
—
131.5
—
—
—
—
—
174
135.2
—
—
—
—
405
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 19
Viscosity Standards
Important Information About Viscosity Standards
in the closed bottle at ambient laboratory temperatures and out of sunlight.
The expiration date on the label is part of Koehler’s program of total quality
control and is intended to ensure that the standard will be utilized while the
certified viscosity data remains valid.
All Koehler certified viscosity standards are Newtonian fluids manufactured
from high stability base oils and polybutenes. The standards have an
expiration date on the label at least twelve months or longer from the date of
purchase. With time, changes resulting from slow oxidation or loss of
volatiles may occur. These changes can be minimized by storing the standard
Cold-Cranking Simulator Viscosity Standards
Approximate Kinematic Viscosity in mPa•s (Centipoise)
Catalog
No.
355-005-010
355-005-012
355-005-014
355-005-016
355-005-019
355-005-022
355-005-025
355-005-028
355-005-032
355-005-038
355-005-048
355-005-060
355-005-074
Viscosity
Standard
CL10
CL12
CL14
CL16
CL19
CL22
CL25
CL28
CL32
CL38
CL48
CL60
CL74
–5°C
23°F
—
—
—
—
—
—
—
—
—
—
2,300
3,700
6,000
–10°C
14°F
—
—
—
—
—
—
—
1,200
1,800
2,900
4,500
7,400
11,600
–15°C
5°F
—
—
—
—
—
1,300
1,800
2,500
3,500
5,800
9,500
15,600
—
–20°C
–4°F
—
—
—
—
1,800
2,500
3,500
5,000
7,300
13,000
21,000
—
—
–25°C
–13°F
—
800
1,600
2,500
3,500
5,100
7,400
9,300
15,900
—
—
—
—
–30°C
–22°F
—
1,600
3,250
5,500
7,400
11,100
17,200
—
—
—
—
—
—
–35°C
–31°F
1,700
3,200
7,000
11,000
17,000
—
—
—
—
—
—
—
—
Low Temperature Viscosity Standards
Catalog No.
355-005-027
355-005-115
Viscosity Standard
N27B
N115B
Viscosities in centipoise at –40,–30, –20, –15, –10, 0°F
Viscosities in centipoise at –20,–15, –10, 0, +10, 20°F
High Viscosity Standards (for asphalts and polymers)
Approximate Viscosity
Catalog
No.
355-004-600
355-004-103
355-004-203
355-004-403
355-004-803
355-004-153
355-004-304
355-004-623
355-004-154
355-004-194
355-004-454
355-004-275
Viscosity
Standard
N600
N1000
N2000
N4000
N8000
N15000
N30000
N62000
N150000
N190000
N450000
N2700000
20°C
68°F
Centipoise
—
—
—
—
—
—
130,000
—
—
900,000
—
—
Kinematic Viscosity
25°C
77°F
Centipoise
1,400
2,000
4,900
11,000
20,000
41,000
80,000
200,000
420,000
520,000
1,600,000
5,300,000
19
60°C
140°F
Centipoise
140
280
380
730
1,400
2,600
4,700
13,000
24,000
33,000
100,000
340,000
60°C
140°F
Centistokes
160
350
440
850
1,600
3,000
5,400
—
—
—
—
—
135°C
275°F
Centistokes
12
—
26
—
—
—
—
—
—
—
—
—
0-12-22_1b_ViscAA_Layout 1 11/29/12 6:06 PM Page 20
Dynamic Viscosity by Rotational Viscometer
Test Method
Determines the dynamic viscosity of a substance by the rotation of a
specified spindle within the sample at the speed giving the maximum
torque reading on the viscometer. The resulting torque reading is used
to calculate the viscosity of the substance
Master Series Rotational Viscometer
• Master Series viscometers, monitored by Master Series Rotational
Viscometer Software, offer a wider and unique range of rheological
applications.
• Touch key board with 12 keys
• Direct readout on a graphic display
• Data displayed
Selected speed: r.p.m.
Selected spindle: SP
Viscosity Reading: cP (mPa·s) or cSt
Percentage of full scale: %
Sample temperature: °C or °F
Shear Rate (with coaxial spindles): SR (s-1)
Shear Stress (with coaxial spindles): SS (N/m2)
Density (introduced by the user): g/cm3
Step Program Status
Analyze & visual characteristics (flow curves)
• Viscosity reading: dynamic viscosity (cP or mPa·s) or kinematic
viscosity (cSt)
• Program features:
Time to torque: target torque pre-setting device
Time to stop: target time pre-setting device
10 working memories
Customizable options
Programmable
Multistep
Ramp
• AUTO-TEST with sound and visual malfunction alarm
• AUTO-RANGE function
• Temperature reading by PT100
• User-enabled viscosity and temperature calibration
• 10 language options
• AISI 316 stainless steel spindles
• Speed:0.01 - 250 r.p.m.
• Number of speeds: 2,600
K447-ML Master Series
Master Series Rotational Viscosity Software
• Complete viscometer control
• Easy to use. All programs eliminate user errors when programming
the instrument to collect data.
• Provides instantaneous viscosity flow curves when performing new
experiments, with definable parameters
• Clear view of program options using flanges
• Definable graphics and zoom function
• Different types of experiments can be programmed: simple curves, ramps,
and multi-step
• All experiments are recorded in different databases to be able to consult
them anytime
• Experiment documentation with name, number, and additional data
• In order to compare different flow curves, up to 4 experiments can
be plotted simultaneously
• Over 12 different charts can be obtained
The Master Series Rotational Viscosity Software is designed to program the
Master Series Viscometer and is a powerful key to document and study the
viscosity behavior of fluids. The Master Series Rotational Viscosity Software is
capable of graphing simple curves, ramps and “multi-step” curves allowing
the user to study trends and the behavior of different materials. A powerful
graph key assists the user to easily design flow curves required.
Specifications (for all Series)
Precision: ±1% of full scale
Resolution:
With low viscosity adapter: 0.01
For lower than 10,000 viscosity cP: 0.1
For viscosity equal to or above 10,000 cP: 1
Repeatability: 0.2%
Thermometer features: (Not Applicable to Bold Series)
Temperature margins: 0°C to +100°C
32°F to 212.0°F
Resolution: 0.1°C/0.1722°F
Precision: +/- 0.1°C
Type of Probe: PT100
Electrical Requirements: 100-240V, 50/60Hz
Measuring Range:
Series L: 20-2,000,000 cP
Series R: 100-13,000,000 cP
Series H: 200-106,000,000 cP
Included Accessories (for all Series)
Standard Spindles (4 for L model, 6 for R and H model)
Viscometer Stand
Spindle Protector
Carrying Case (Not Applicable to Bold Series)
USB Cable (Not Applicable to Bold Series)
Datalogger Software (Not Applicable to Bold Series)
20
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 21
Dynamic Viscosity by Rotational Viscometer
Sharp Series Rotational Viscometer
Power Series Rotational Viscometer
•
•
•
•
• Touch key board with 12 keys
• Direct readout on a graphic display
• Data displayed
Selected speed: r.p.m.
Selected spindle: SP
Viscosity reading: cP (mPa·s) or cSt
Percentage of full scale: %
Sample temperature: °C or °F
Shear Rate (with coaxial spindles): SR (s-1)
Shear Stress (with coaxial spindles): SS (N/m2)
Density (introduced by the user): g/cm3
• Unit converter SI to CGS
• Program features:
Time to torque: target torque pre-setting device
Time to stop: target time pre-setting device
10 working memories
Customizable options
Programmable
Multistep
Ramp
• AUTO-TEST with sound and visual malfunction alarm
• AUTO-RANGE function
• Temperature reading by PT100
• User-enabled viscosity and temperature calibration
• 10 language options
• Interface: USB
• Datalogger Software: USB allows data transfer to a PC Excel format
• AISI 316 Stainless steel spindles
• Speed: 0.01 - 200 r.p.m.
• Number of speeds: 54
•
•
•
•
•
•
•
•
•
•
•
•
•
Indispensable in QC and R&D laboratories.
Touch key board with 6 keys
Direct readout on graphic display
Data displayed
Selected speed: r.p.m.
Selected spindle: SP
Viscosity reading: cP (mPa·s) or cSt
Percentage of full scale: %
Sample temperature: °C or °F (optional)
Shear rate (with coaxial spindles): SR (s-1)
Shear stress (with coaxial spindles): SS (N/m2)
Density (introduced by the user): g/cm3
Viscosity reading: dynamic viscosity (cP or mPa·s) or kinematic viscosity (cSt)
Unit converter SI to CGS
Program features:
Time to torque: target torque pre-setting device
Time to stop: target time pre-setting device
10 working memories
AUTO-TEST with sound and visual malfunction alarm
AUTO-RANGE function
Temperature reading by PT100 (optional)
User-enabled viscosity and temperature (optional) calibration
10 language options
Interface: USB
Datalogger Software: USB allows data transfer to a PC Excel format
AISI 316 stainless steel spindles
Speed: 0.3 - 100 r.p.m
Number of speeds: 18
n
Ordering Information
Catalog No.
K447-ML
K447-MR
K447-MH
K447-ML-SFW
K447-MR-SFW
K447-MH-SFW
Master Series L Rotational Viscometer
Master Series R Rotational Viscometer
Master Series H Rotational Viscometer
Master Series L Rotational Viscometer with Software
Master Series R Rotational Viscometer with Software
Master Series H Rotational Viscometer with Software
K447-PL
K447-PR
K447-PH
Power Series L Rotational Viscometer
Power Series R Rotational Viscometer
Power Series H Rotational Viscometer
K447-SL
K447-SR
K447-SH
K447-SL-PT
K447-SR-PT
K447-SH-PT
Sharp Series L Rotational Viscometer
Sharp Series R Rotational Viscometer
Sharp Series H Rotational Viscometer
Sharp Series L Rotational Viscometer with PT100 Probe
Sharp Series R Rotational Viscometer with PT100 Probe
Sharp Series H Rotational Viscometer with PT100 Probe
K447-BL
K447-BR
K447-BH
Bold Series L Rotational Viscometer
Bold Series R Rotational Viscometer
Bold Series H Rotational Viscometer
Bold Series Rotational Viscometer
• Bold series viscometers allow fast and
accurate viscosity readings.
• They are low budget and easy to use.
• Data Displayed
Selected speed: r.p.m.
Selected spindle: SP
Viscosity Reading: cP (mPa·s)
Percentage of full scale: %
• Relative and absolute viscosity
• Unit converter SI to CGS
• AUTO-TEST with sound and visual malfunction alarm
• AUTO-RANGE function
• User-enabled calibration
• 10 language options
• AISI 316 stainless steel spindles
• Speed: 0.3 - 100 r.p.m.
• Number of speeds: 18
Accessories
K447-SSA-CJ
Small Sample Adapter w/circulation jacket
(without spindles)
K447-SSA
Small Sample Adapter without circulation jacket
(without spindles)
K447-SSP-SETL Set of special spindles (L5, L6, L7)
for small sample adapters (L Model)
K447-SSP-SETRH Set of special spindles (RH8, RH9, RH10, RH11)
for small sample adapters (R & H Models)
K447-LVA-CJ
Low Viscosity Adapter w/circulation jacket
K447-LVA
Low Viscosity Adapter without circulation jacket
K447-SP-LVA
Spindle for Low Viscosity Adapter
K447-HDU
Helix Drive Unit, Heldal
21
0-12-22_1b_Visc_Layout 1 10/24/12 10:54 AM Page 22
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Kinematic Viscosity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 2-13
ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550;
FTM 791-305
Petroleum Ether
Chromic Acid
Petroleum Spirit
Toluene
Plumb Line or Spirit Level
Petroleum Naphtha
Xylene
Acetone
Distilled Water
Saybolt Viscosity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pages 16-17
ASTM D88, D244, E102; AASHTO T72; FTM 791-304
Balance
No. 50 (300-µm) Sieve
Condenser – Water Cooled Reflex Glass-tube
Xylol
No. 20 (850-µm) Sieve
Filter Funnel
Hot Plate (E102)
22
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 23
Penetration
Test Methods
Penetration of Bituminous Materials ASTM D5; IP 49; DIN 52010
Cone Penetration of Lubricating Grease ASTM D217; IP 50;
ISO 2137; DIN 51804; FTM 791-311, FTM 791-313
Cone Penetration of Petrolatum ASTM D937; IP 179;
ISO 2137; DIN 51580
Needle Penetration of Petroleum Waxes ASTM D1321;
IP 376; DIN 51579
Cone Penetration of Lubricating Grease Using One-Quarter and
One-Half Scale Cone Equipment ASTM D1403; IP 310; ISO 2137;
DIN 51804
Yield Stress of Heterogeneous Propellants by Cone Penetration
Method ASTM D2884
Roll Stability of Lubricating Grease ASTM D1831
www.koehlerinstrument.com
www.koehlerinstrument.com
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 24
Penetration
Penetration of Bituminous Materials
Cone Penetration of Lubricating Grease
Cone Penetration of Petrolatum
Needle Penetration of Petroleum Waxes
Cone Penetration of Lubricating Grease Using
One-Quarter and One-Half Scale Cone Equipment
Yield Stress of Heterogeneous Propellants by
Cone Penetration Method
Test Method
Penetration tests are performed on petroleum products to determine
consistency and shear stability (lubricating greases) for design, quality
control and identification purposes. A standard cone or needle is released
from a penetrometer and allowed to drop freely into the sample for
5 seconds (or a different specified interval) at constant temperature. The
depth of penetration of the cone or needle into the sample is measured in
tenths of a millimeter by the penetrometer.
Penetrometer
• Conforms to ASTM and related specifications for penetrometers
• Suitable for laboratory or field use
Designed for ASTM penetration tests on petroleum products and for
consistency tests on a wide range of food products, cosmetics, pastes and
other solid to semi-solid products. Precision machined and assembled to
exacting specifications, and ruggedly constructed to insure long service life
in both laboratory and field applications. Features a full penetration range
of 0-62.0mm with 1⁄10mm subdivisions (0-620 penetration scale).
Accommodates cones and needles to perform all of the ASTM tests on
lubricating greases, asphalts, petroleum waxes and petrolatums. Compact
design facilitates transport for field use. Head assembly adjusts for accurate
placement of the tip of the needle or cone on the surface of the sample.
Sturdy cast iron base provides excellent support and has a built-in spirit level
and leveling screws to insure proper alignment of the penetrometer during
testing. Supplied with 50 and 100 gram weights and standard 47.5g
plunger assembly. Order test cones, needles and lightweight plunger
(where applicable) separately.
K19500 Penetrometer with K20800 Penetration Cone
Ordering Information
Catalog No.
K19500
Penetrometer
Accessories
K19552
K19553
K19520
K20910
K19525
K19510
K19535
K19536
Specifications
Calibration Kit
Consists of 0.500, 1.000 and 2.000" gauge blocks with
calibration certificate traceable to NIST
Calibration Kit, Metric
Consists of 12.5mm, 25mm and 45mm gauge blocks with
calibration certificate traceable to NIST
Plunger, 15g
For use with K20200, K19800 and K20300 Cones
Plunger, 6.9g
For use with K20900 Cone
Plunger, 47.5g
Auxiliary Weight Set
Includes one each 2.5g, 5g and 10g weights
and two 20g weights
Loading Weight, 50g
Loading Weight, 100g
Conforms to the specifications of:
ASTM D5, D217, D937, D1321, D1403, D2884, D4950, D5329; IP 49, 50,
179, 310; ISO 2137; DIN 51579, 51580, 51804; FTM 791-311, 791-312,
791-313; AOCS Cc 16-60; AACC 58-14; NFT 60-119, 60-123, 60-132,
66-004
Included Accessories
Plunger, 47.5g
Weights, 50 and 100g
Dimensions lxwxh,in.(cm)
6x6x18 (15x15x46)
Net Weight: 12 lbs (5.4kg)
Shipping Information
Shipping Weight: 15 lbs (6.8kg)
Dimensions: 1.7 Cu. ft.
24
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 25
Penetration
Microprocessor Based Digital Penetrometer
• Tests the consistency of lubricating greases, petroleum waxes, bitumens,
pastes, creams and other solid to semi-solid products
• Automatically timed operator programmable penetration measurements
• Motorized placement of penetrator on sample surface
• Large LCD to display all functions
• RS232 port for data transfer
• Full measurement range of 0-620 in 1⁄10mm scale or 1⁄100mm scale
• Rechargeable battery or AC operation
• Large, removable base accommodates grease worker cups and other
ASTM and non-standard sample containers
• Complete selection of penetrometer cones, needles and accessories for
petroleum products testing and for a wide range of other applications
• Conforms to all ASTM, IP, ISO 9001 and related specifications for
penetrometers
Microprocessor based penetrometer loaded with advanced features to provide
ease of operation and highly reproducible consistency measurements of
petroleum products. Microprocessor control provides a full range of
measurement and reporting options, and operation is simplified by four
user programmable presets that facilitate lowering the penetrator tip to
the sample surface.
Automatically timed penetrations—The penetrometer defaults to the
standard ASTM interval of 5.0 seconds, or the operator may conveniently
program a different interval in the range between 0.1 and 9999.9 seconds
(in 0.1 second increments). A curing or temperature stabilization period
may also be programmed by the operator (to delay the release of the
penetrator into the sample) and for added convenience all selected
parameters are retained in memory and automatically repeated in
subsequent tests until changed by the operator. Separate keypad controls
for each parameter simplify operation. Penetration and delay intervals
count down on a large, easy to read LCD on the head of the unit.
Convenient measurement and reporting options—Penetration measurements
in the full range of 0 - 620 in 1⁄10mm scale are reported in either 1⁄10mm or 1⁄100mm
increments at the operator’s option. For quality control testing, a penetration
range can be entered into memory prior to testing. If a test result falls outside
of the programmed range, an audible signal and visual error message alert the
operator of a failed sample. Test results are displayed in digital format on a
large LCD readout on the head of the penetrometer and can be communicated
to a printer or computer via a built-in RS232 interface.
Simplified penetrator tip placement—Correct placement of the penetrator tip
on the sample surface is essential for accurate penetration test results. The
Koehler Digital Penetrometer has four operator programmable presets that
lower the penetrator to the sample surface height at the touch of a button,
greatly simplifying the process to ensure reproducibility. A fine adjustment
button permits slight adjustments as needed. Full manual operation is also
available with the use of coarse and fine push button controls and built-in
magnifier and illuminator arms. When testing electrically conductive samples,
a built-in circuit senses the sample surface for automatic placement. After
testing, the penetrometer head returns to a raised position at the touch of a
button to facilitate cleaning of the penetrator and changing of the sample.
More convenience features—The detachable machined base provides a large
platform to accommodate a wide range of sample containers and constant
temperature cylinders. It removes easily to permit the head assembly to be
reversed (for use with a constant temperature bath) or mounted directly to a
bath housing or other location. A built-in rechargeable battery pack permits
field operation and provides back-up in the event of power interruption.
Battery recharges automatically during operation of the penetrometer on
standard AC electrical service.
K95500 Digital Penetrometer
Specifications
Conforms to the specifications of: ASTM D5, D217, D937, D1321, D1403,
D2884, D4950, D5329; IP 49, 50, 179, 310; ISO 2137; DIN 51579, 51580,
51804; FTM 791-311, 791-312, 791-313; AOCS Cc 16-60; AACC 58-14;
NFT 60-119, 60-123, 60-132, 66-004
Penetration Range: 0-62.0mm (0-620 penetration scale) in 1⁄10mm or 1⁄100mm
Penetration Interval: Operator variable from 0.1 to 9999.9 seconds
with automatic repeat function and 5.0 second default
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Included Accessories
Dimensions lxwxh,in.(cm)
Shipping Information
Standard Plunger, 47.5g
Weights, 50 and 100g
Base: 121⁄2x14 (31.7x35.6)
Shipping Weight: 27 lbs (12.3kg)
Overall: 121⁄2x14x18 (31.7x35.6x45.7) Dimensions: 2 Cu. ft.
Net Weight: 21 lbs (9.5kg)
Ordering Information
Catalog No.
K95500-00000 Digital Penetrometer, 115V, 60Hz
K95590-00000 Digital Penetrometer, 220-240V, 50/60Hz
Order Qty
1
Accessories
K19552
Calibration Kit - Consists of 0.500, 1.000 and 2.000"
gauge blocks with calibration certificate traceable to NIST
K19553
Calibration Kit, Metric - Consists of 12.5mm, 25mm and
45mm gauge blocks with calibration certificate traceable
to NIST
K95573-00000 Plunger, 15g - For use with K20200, K19800 and
K20300 Cones
K95519-00000 Plunger, 6.9g - For use with K20900 Cone
K95577
Standard Plunger, 47.5g
K19587
Loading Weight, 50g
K19588
Loading Weight, 100g
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
≥
Software compatible, inquire
with Koehler Customer Service.
25
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 26
Penetration
Penetrometer Cones, Needles and Accessories
•
•
•
•
•
•
Needle Penetration of Petroleum Waxes
Precision machined cones and needles for ASTM and related methods
Sample containers
Constant temperature baths
Grease workers and accessories
Roll stability testers
USDA and AOCS penetrometer cones
Test Method Standards
ASTM D1321; IP 376; DIN 51579
K17700
K17770
K17710
Use together with K19500 and K95500 series penetrometers to determine
the consistency of petroleum products. Please call or write for information
on non-petroleum test applications.
K95600
K95690
Needle, Stainless Steel, 2.5g
Needle, Stainless Steel, 2.5g, NIST Certified
Wax Specimen Container
Brass cylinder with base plate
conforming to ASTM D1321 specifications
Penetration Bath, 115V, 60Hz
Penetration Bath, 230V, 50/60Hz
K20800
K20500
K17700
K20090 Aluminum Cone
K20000 Brass Cone
Penetration of Bituminous Materials
Cone Penetration of Lubricating Greases
Test Method Standards
Test Method Standards
ASTM D5; IP 49; DIN 52010
ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313
K20500-00000
K20570-00000
K20600-00000
K20670-00000
388-001-003
388-001-006
357-000-001
K95600
K95690
Needle.
Stainless steel with brass ferrule, 2.5g
Needle.
Similar to K20500, NIST certified, 2.5g
Needle.
Stainless steel with stainless steel ferrule, 2.5g
Needle.
Similar to K20600, NIST certified, 2.5g
Sample Container,
55mm dia. x 35mm depth for penetrations below 200
Sample Container,
70mm dia. x 45mm depth for penetrations
between 200 to 350
Transfer Dish
Submerges sample container per ASTM specifications
Penetration Bath, 115V, 60Hz
Penetration Bath, 230V, 50/60Hz
K20800
K20000
K18100
K19100
K95600
K95690
Cone, Magnesium
With hardened stainless steel tip, 102.5g
Standard cone per ASTM D217
Cone, Brass
With hardened stainless steel tip, 102.5g
Optional cone per ASTM D217
Grease Worker series. Refer to page 28 for
specifications and ordering information
Grease Cutter
For ‘block penetration’ tests
Penetration Bath, 115V, 60Hz
Penetration Bath, 230V, 50/60Hz
Please inquire with Koehler Customer Service about accessories
for food, cosmetics, paints, soaps, and other consistency
measurement applications utilizing the Penetrometer.
26
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 27
Penetration
Cone Penetration of Lubricating Grease Using
One-Quarter and One-Half Scale Cone Equipment
Test Method Standards
ASTM D1403; IP 310; ISO 2137; DIN 51804
K20900
K95519-00000
K20910
K21000
K21002
K21001
K20200
K95573-00000
K20200
K20210
K21000
K20900
K19520
K20210
K95600
K95690
Cone Penetration of Petrolatum
Test Method Standards
Quarter-Scale Cone, Aluminum, 2.48g
Plunger, 6.9g
For use with K95500 series Digital Penetrometer
Plunger, 6.9g
For use with K19500 series Penetrometer
Quarter-Scale Grease Worker
Consists of cup and cover assembly with
plunger plate, shaft, handle and valve
Retaining Base Plate
Mounts on bench or wall to retain
Quarter-Scale Grease Worker
when working heavy greases.
Blank Lid
With seal, for Quarter-Scale Grease Worker.
Use when heating samples prior to test.
Half-Scale Cone. Stainless Steel, 22.5g
Plunger, 15g
For use with K95500 series Digital Penetrometer
Plunger, 15g
For use with K19500 Penetrometer
Half-Scale Grease Worker
Penetration Bath, 115V, 60Hz
Penetration Bath, 230V, 50/60Hz
ASTM D937; IP 179; ISO 2137; DIN 51580
K20800
K20700
K95600
K95690
Cone, Magnesium
With hardened stainless steel tip, 102.5g
Sample Container
With cover, conforms to ASTM D937 specifications
Penetration Bath, 115V, 60Hz
Penetration Bath, 230V, 50/60Hz
Roll Stability of Lubricating Grease
Test Method Standard
ASTM D1831
K18300
K20900
Roll Stability Tester series (page 156)
Cone Penetration Test Equipment,
One-Quarter or One-Half Scale series
Additional Penetration Cones
K19800
K19900
K20090
K20300
Magnesium Cone, 15g
For ASTM D2884 testing of Heterogeneous Propellants
Aluminum Cone, 45g
For AOCS CC 16-60 testing of fats, butter, margarine
Aluminum Cone, 35g
For USDA testing of pastes
Aluminum Micro-Cone, 5g
For lubricating greases, cosmetic creams. Use together
with K20310 Sample Cup and Collar
K20300 Aluminum Micro Cone
27
K19900 Aluminum Cone
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 28
Penetration
Grease Workers
• Conform to ASTM D217 and related specifications
• Mechanical and manually operated types
• Single and double-unit models
Mechanical Grease Workers–For “worked penetration’’ and “prolonged
worked penetration” tests to determine consistency of lubricating greases.
Consists of single or dual steel ASTM grease workers mounted on a sturdy
base and driven by a powerful gear reduction motor. Meets ASTM
specifications for stroke length and rate. Equipped with a presetting
electronic counter that automatically shuts off the drive motor after any desired
number of strokes up to 99,999. Steel grease workers have threaded cup and
cover, and steel plunger plate with shaft and handle that connects to eccentric
cam on drive unit. Accessory dial thermometer inserts in plated vent cock.
Spring loaded tightening clamps hold grease workers securely on base, and
steel pins in base facilitate disassembly of grease workers after testing.
Manually Operated Grease Worker–Hand lever operated grease working
machine designed for short duration ‘’worked penetration” tests on lubricating
greases. Consists of one steel ASTM grease worker with hand lever
mechanism mounted on a sturdy steel base. Spring loaded tightening clamps
hold grease worker securely on base, and steel pins in hand lever upright
support facilitate disassembly of grease worker. Base plate is drilled at corners
to allow for bolting to table top.
K18190 Mechanical Grease Worker
Ordering Information
Catalog No.
Mechanical Grease Workers
K18100
Single-Unit Model, 115V 60Hz
K18110
Single-Unit Model, 220-240V 50Hz
K18119
Single-Unit Model, 220-240V 60Hz
K18190
Double-Unit Model, 115V 60Hz
K18191
Double-Unit Model, 220-240V 50Hz
K18192
Double-Unit Model, 220-240V 60Hz
Manually Operated Model
K18000
Grease Working Machine
For Quarter-Scale and Half-Scale Grease Workers, refer to page 27.
Specifications
Conforms to the specifications of:
ASTM D217, D4950; IP 50; ISO 2137; DIN 51804; FTM 791-311, 791-313*
*Requires substitution of 270-hole grease worker (K18030)
Drive Motor: fan cooled gear reduction type, 1⁄3hp (single-unit model)
or 1⁄2 hp (dual-unit model)
Electrical Requirements:
Mechanical Grease Workers:
115V 60Hz, Single Phase, 3A
220-240V 50/60Hz, Single Phase, 1.5A
Included Accessories
Accessories
K18022
K18021
K18020
K18030
K18028
K18029
K18023
Mechanical ASTM Steel Grease Worker (1 or 2)
Dial Thermometer
Inserts in petcock of steel grease worker.
Supplied with adapter.
Overflow Ring
Collects displaced grease during
penetration measurements.
Steel Grease Worker
Complete per ASTM specifications.
Consists of cup, cover, plunger and vent cock.
Steel Grease Worker
Similar to K18020 above, but with 270-hole plunger
plate per FTM 791-313 (AN-G-15) specifications.
Cover Assembly
Replacement cover assembly for steel grease worker.
Includes vent cock, plunger plate, shaft and handle.
Grease Cup
Blank Lid, with seal
For ASTM Steel Grease Worker.
Use when heating samples prior to test.
Dimensions lxwxh,in.(cm)
Mechanical Grease Workers:
Single-Unit: 10x131⁄2 x143⁄4 (25x34x37)
Double-Unit: 14x131⁄2 x143⁄4 (36x34x37)
Manually Operated Grease Worker: 30x10x151⁄2 (76x25x39)
Net Weight:
Mechanical Single-Unit: 106 lbs (48.1kg)
Mechanical Double-Unit: 1391⁄2 lbs (63.3kg)
Manual: 21 lbs (9.6kg)
Shipping Information
Shipping Weight: Single-Unit: 141 lbs (64.0kg)
Mechanical Double-Unit: 171 lbs (77.6kg)
Manual: 28 Ibs (12.7kg)
Dimensions: Mechanical: 4.2 Cu. ft.; Manual: 2.7 Cu. ft.
28
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 29
Penetration
Penetrometer Bath
• Conforms to ASTM and related specifications
• Conditions petroleum samples and others requiring close temperature
control prior to or during testing
• For use with manual and microprocessor penetrometer models
• Digital temperature control with low-liquid and overtemperature
safety cut off
Constant temperature water bath for conditioning samples prior to a
penetration test. Full visibility bath has a large shelf to accommodate a wide
range of sample containers, including all containers used in ASTM tests.
Sample containers can be left in the bath during the penetration test if required.
The base of the Koehler manual penetrometer can be placed directly on the
shelf of the bath, or the head assembly of the digital automatic model can be
reversed to overhang the bath. Microprocessor digital temperature control
maintains bath liquid temperature with ±0.05°C stability throughout the
operating range. A large LED provides bath temperature readout in switchable
°C/°F format and a dual-speed circulating pump assures temperature
uniformity. The bath is protected by a separate adjustable overtemperature
thermostat and a low liquid cut-off. A built-in cooling coil is provided for
circulating a refrigerated coolant or tap water if needed.
K95600 Penetrometer Bath
Specifications
Conforms to the specifications of:
ASTM D5, D217, D937, D1321, D1403, D2884, D5329
Temperature Range: Ambient to 70°C
Temperature Stability: 0.05°C (0.1°F)
Electrical Requirements:
115V 60Hz, Single Phase, 9A
220-240V 50/60Hz, Single Phase, 4.5A
Ordering Information
Catalog No.
K95600
K95690
Penetrometer Bath, 115V 60Hz
Penetrometer Bath, 230V 50/60Hz
Accessories
250-000-17F
ASTM 17F Thermometer
Range: 66 to 80°F
250-000-17C ASTM 17C Thermometer
Range: 19 to 27°C
250-000-63F ASTM 63F Thermometer
Range: 18 to 89°F
250-000-63C ASTM 63C Thermometer
Range: –8 to +32°C
250-000-64F ASTM 64F Thermometer
Range: 77 to 131°F
250-000-64C ASTM 64C Thermometer
Range: 25 to 55°C
Dimensions lxwxh,in.(cm)
18x131⁄8x81⁄2 (45.7x33x21.6)
Net Weight: 6 lbs (2.7kg)
Shipping Information
Shipping Weight: 10 lbs (4.5kg)
Dimensions: 1.2 Cu. ft.
Please inquire with Koehler Customer Service about Stainless
Steel Bath option.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
29
0-23-30_2_Penetration_Layout 1 10/24/12 10:56 AM Page 30
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Cone Penetration of Lubricating Grease ................................Page 26
ASTM D217; IP 50; ISO 2137; DIN 51804; FTM 791-311, FTM 791-313
Spatula
Paper
Light Petroleum Naphtha
Needle Penetration of Petroleum Waxes...............................Page 26
ASTM D1321; IP 376; DIN 51579
Glycerin
Cone Penetration of Petrolatum..............................................Page 27
ASTM D937; IP 179; ISO 2137; DIN 51580
Laboratory Oven
Cone Penetration of Lubricating Grease Using One-Quarter
and One-Half Scale Cone Equipment .....................................Page 27
ASTM D1403; IP 310; ISO 2137; DIN 51804
Spatula
30
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 31
Flash Point
Test Methods
Page
Flash Point by Automatic Pensky-Martens Closed Tester
ASTM D93; IP 34; ISO 2719; DIN EN 22719; NF M 07-019;
JIS K2265 ................................................................................................32
Flash Point by Automatic Abel Tester
IP 170, 304; ISO 1523, 13736; NF M 07-011; NF T 06-009 ................32
Flash Point by Automatic Tag Closed Tester
ASTM D56; IP 304 ..................................................................................33
Flash Point and Fire Points by Automatic Cleveland
Open-Cup Tester ASTM D92; IP 36; ISO 2592......................................33
Flash Point by Pensky-Martens Closed Tester
ASTM D93; AASHTO T73-811; IP 34; ISO 2719;
DIN 51758; FTM 791-1102 ....................................................................34
Flash Point by Tag Closed Tester
ASTM D56; IP 304; FTM 791-1101 ........................................................35
Flash Point and Fire Points by Cleveland Open-Cup Tester
ASTM D92; IP 36; ISO 2592; DIN 51376;
FTM 791-1103, FTM 141-4294 ..............................................................36
Flash Point and Fire Points of Liquids by Tag
Open-Cup Apparatus ASTM D1310 ......................................................37
Flash Point of Cutback Asphalt with Tag Open-Cup Apparatus
ASTM D3143............................................................................................37
Flash Point of Liquids by Small Scale Closed Cup Apparatus
ASTM D3278, D3828, D4206; DOT CFR 49-173.115;
IATA; ISO 9038 ........................................................................................38
Autoignition Temperature of Liquid Chemicals
ASTM E659 ..............................................................................................39
www.koehlerinstrument.com
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 32
Automated Flash Point Testers
Auto Pensky-Martens Closed Cup Flash Point Tester
• Conforms to ASTM D93 and related specifications
• Dual flash point detection system (thermal and ionization) for
measurement of samples containing water and/or silicone
• Gas or electric ignition
• Flash point operation range between 0 and 400°C
• Simple automation routine for easy operation
• Large viewing screen for observing test status at a distance from the unit
• Automatic barometric correction
The automated Pensky-Martens flash point tester accurately determines the
lowest flash point temperature of fuels, lubricating oils, and homogenous
liquids (ASTM D93 A), or liquids containing suspended solids as well as
liquids that tend to form a surface film during testing (ASTM D93 B). Flash
point tests are simply conducted by mounting the flash cup filled with sample
into the test position and selecting a pre- or user-programmed test method. A
quick search method allows for determination of flash points for unknown
samples and a method for asphalts is also included. The automation routines
provide accurate test results, even with users inexperienced in flash point test
methods. The flash point test result is automatically corrected to standard
pressure (101.3 kPa). The unit is equipped with a differential Pt-100 RTD
probe designed to duplicate the response time of a mercury-in-glass
thermometer as per ASTM D93-02a and E1-03a. The system features multiple
sensors for continually monitoring of instrument function and displaying an
error message if a problem is detected. The performance of the electrical
ignitor is continuously checked, and the user is notified upon the need of
replacement due to either damage or the end of its useful life. The system is
easily interfaced with an external PC for operation and method updates. When
performing a test, the system will display the stirring speed, temperature curve
(also printed out), and current test status. The system alerts the user if the first
application of the ignitor results in a flash or if no flash point is detected at the
end of the test program. If a flash is not detected 30°C above the expected
flash point or at 400°C, then the test is automatically aborted for safety. An
easy connection to the air ventilation system or external water connection
provides a quick cool down between test runs for operational efficiency.
Automated Pensky-Martens Flash Point Tester
Automatic Abel Flash Point Tester
• Conforms to IP 170 and related specifications
• Simple automation routine for easy operation
The automated Abel flash point tester is used primarily to test flammable
and combustible materials for shipping and safety regulations. The flash
tester provides an increased temperature range of operation as compared
with other testers, allowing greater flexibility in testing samples according
to the Abel test method. The unit provides a test range to 110°C and can
be extended to –30°C by any appropriate external chiller. The flash point
tests are simply conducted by mounting the flash cup filled with sample
into the test position and selecting a pre- or user-programmed test
method. Automation routines provide accurate test results. A quick
search method is available to determine the flash point of unknown
samples. The dual detection system (thermal and ionization) allows for
testing all types of products. Ignition by gas flame or electrical ignitor is
included, along with safety cut-off devices. Test results are automatically
corrected to standard pressure (101.3 kPa). The system is equipped with
a differential Pt-100 RTD probe designed to duplicate the response
time of a mercury-in-glass thermometer and with multiple sensors that
continually monitor instrument function, displaying an error message if a
problem is detected. Supervision software is included.
Specifications
Conforms to the specifications of:
ASTM D93; IP 34; ISO 2719; DIN EN 22719;
NF M 07-019; JIS K2265
Electrical Requirements:
115V 60Hz 1000W
230V 50/60Hz 1000W
Dimensions lxwxh,in.(cm)
10.25x21x19.75(26x5.53x50)
Net Weight:
44 lbs (20kg)
Temperature range of Flash Tester can be extended. Please contact Koehler
Customer Service for additional information.
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
IP 170; ISO 1523, 13736;
NF M 07-011; NF T 66-009
Electrical Requirements:
115V 60Hz, Single Phase
230V 50/60Hz, Single Phase
10.25 x21x19.75 (26x5.53x50)
Net Weight:
44 lbs (20kg)
32
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 33
Automated Flash Point Testers
Automatic Tag Closed Cup Flash Point Tester
Automatic Cleveland Open Cup Flash Point Tester
• Conforms to ASTM D56 and related specifications
• Simple automation routine for easy operation
•
•
•
•
The automated Tag Closed Cup flash point tester ensures the accuracy and
precision required according to the ASTM D56 and related test methods.
The test sample is heated at a prescribed rate of temperature increase
throughout the standard temperature test range to 100°C. The flash point
tests are simply conducted by mounting the flash cup filled with sample
into the test position and selecting a pre-programmed test method or the
search mode to determine an approximate flash point. The automation
routines provide accurate test results. Ignition by gas flame or electrical
ignitor is included, along with safety cut-off devices. The measurement
range can be extended to –30°C by any appropriate external chiller.
Supervision software is included.
The automated Cleveland Open Cup flash point tester accurately determines
flash and fire point temperatures of viscous petroleum products including oils
and bitumens over an extended temperature range. When examining highly
viscous specimens, a preheating time and temperature are set in order to
liquefy the sample for testing. The surface skin from bituminous samples can
be removed with a skimmer. The flash/fire point tests are simply conducted by
mounting the flash cup filled with sample into the test position and selecting
a pre-programmed test method or the search mode to determine an
approximate flash point. The test results are automatically corrected to
standard pressure (101.3 kPa). Equipped with a differential Pt-100 RTD probe,
the system is designed to duplicate the response time of a mercury-in-glass
thermometer. Multiple sensors continually monitor instrument function,
displaying an error message if a problem is detected. The performance of the
ionization sensor which detects the flash and fire points is continuously
monitored, and the user is notified upon the need of replacement. If a flash is
not detected 20°C above the expected flash point or at 420°C, then the test
is automatically aborted for safety. The system is easily interfaced with an
external PC for operation and method updates. When performing a test, the
system will display the stirring speed, temperature curve (also printed out),
and current test status. The system alerts the user if the first application of the
ignitor results in a flash or if no flash point is detected at the end of the test
program. If a flash is not detected 30°C above the expected flash point or at
400°C, then the test is automatically aborted for safety.
Temperature range of Flash Tester can be extended. Please contact Koehler
Customer Service for additional information.
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
ASTM D56; IP 304
Electrical Requirements:
115V 60Hz, Single Phase
230V 50/60Hz, Single Phase
21 x10.5x19.75 (53.5x26x50)
Net Weight:
44 lbs (20kg)
Conforms to ASTM D92 and related specifications
Simple automation routine for easy operation
Flash point operation between ambient and 400°C
Gas or electric ignition
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
ASTM D92; IP 36; ISO 2592
Electrical Requirements:
115V 60Hz 1000W
230V 50/60Hz 1000W
21x10.5x19.75(53.5x26x50)
Net Weight:
44 lbs (20kg)
Ordering Information
Catalog No.
Order Qty
Automatic Abel Flash Point Tester
1
K87300
Automatic Abel Flash Point Tester, 115V 60Hz
K87390
Automatic Abel Flash Point Tester, 230V 50/60Hz
Automated Tag closed Cup Flash Point Tester
33
Automatic Pensky-Martens Closed Cup Flash Point Tester
K87100
Automatic Pensky-Martens Closed Cup
Flash Point Tester, 115V 60Hz
K87190
Automatic Pensky-Martens Closed Cup
Flash Point Tester, 230V 50/60Hz
1
Automatic Tag Closed Cup Flash Point Tester
K87700
Automatic Tag Closed Cup
Flash Point Tester, 115V 60Hz
K87790
Automatic Tag Closed Cup
Flash Point Tester, 230V 50/60Hz
1
Automatic Cleveland Open Cup Flash Point Tester
K87400
Automatic Cleveland Open Cup
Flash Point Tester, 115V 60Hz
K87490
Automatic Cleveland Open Cup
Flash Point Tester, 230V 50/60Hz
1
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 34
Flash Point by Pensky-Martens Closed Cup Tester
Test Method
For flash point determinations of fuels, lubricating oils, liquids
containing suspended solids and liquids that tend to form a surface
film during testing.
Pensky-Martens Closed Cup Flash Tester
• Conforms to ASTM D93 and related specifications
• Choice of electric or gas heating
Determines flash points of a wide range of products by a closed cup
method with two option speed stirring of the sample. Extensively used
in shipping and safety regulations for detection of contamination by
volatile and flammable materials in fuel oils and lubricating oils, and for
characterization of hazardous waste samples.
Smooth operating cover mechanism slides shutter open and applies test flame
at the turn of a knob. Cover fits over brass test cup and includes pilot flame,
test flame reference bead, built-in stirrer and plated brass thermometer ferrule.
Electrically heated model is equipped with a 1000W nickel-chromium
heater with stepless variable control for accurate, repeatable temperature
rate of rise settings per specifications. Heater unit is enclosed in a
stainless steel housing with cooling vents. Includes line cord receptacle
and switch for accessory slow speed stirrer.
Gas heated model has a built-in nickel plated brass natural gas burner, or can
be supplied with an artificial gas burner or liquid propane burner (specify
when ordering). Both models are mounted on a sturdy cast iron base.
Ordering Information
Catalog No.
Pensky-Martens Closed Cup Flash Tester
K16200
Electrically Heated Model,
115V 60Hz
K16270
Electrically Heated Model,
220-240V 50/60Hz
K16000
Gas Heated Model
K16200 Pensky-Martens Flash Tester with
K16220 Accessory Stirrer Motor (Sold Separately)
Specifications
Conforms to the specifications of:
ASTM D93; AASHTO T73-811; IP 34; ISO 2719; DIN 51758; FTM 791-1102;
NF M 07-019
Electrical Requirements:
115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase, 3.4A
Order Qty
1
Accessories
K16220
Included Accessories
Brass Test Cup with Handle
Thermometer Holder
Cover Assembly
K16228
K16229
250-000-09F
Dimensions lxwxh,in.(cm)
91⁄2 x8x221⁄2 (24x20x57) with optional stirrer motor installed
Net Weight:
K16000: 21 lbs (9.5kg)
K16200/K16270: 24 lbs (10.9kg)
250-000-09C
250-000-10F
Shipping Information
Shipping Weight: 30 lbs (13.6kg)
Dimensions: 3.1 Cu. ft.
250-000-10C
Please refer to page 32 about our automated Pensky-Martens
Closed Cup Flash Point Tester or inquire by contacting Koehler
Customer Service.
K16010
K16020
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
K16020-NI
34
Stirrer Motor, 115V 60Hz
Slow speed gear motor rotates stirrer of
Pensky-Martens Tester at 115rpm for
Procedure A and at 250rpm for Procedure B.
Includes adjustable support bracket and
mounting rod. Installs in base of flash tester.
Stirrer Motor, 220-240V 60Hz
Stirrer Motor, 220-240V 50Hz
ASTM 9F Thermometer
Range: 20 to 230°F
ASTM 9C Thermometer
Range: –5 to +110°C
ASTM 10F Thermometer
Range: 200 to 700°F
ASTM 10C Thermometer
Range: 90 to 370°C
Cover Assembly
Complete assembly. Includes shutter, flame
exposure device, stirrer and thermometer ferrule.
Brass Test Cup
With heat resistant handle.
Nickel Plated Test Cup
With heat resistant handle
1
1
1
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 35
Flash Point by Tag Closed Tester
Test Method
For flash point determinations of liquids with a viscosity of below 5.5
centistokes (cSt) at 104°F (40°C) or below 9.5cSt at 77°F (25°C), and a
flash point below 200°F (93°C) except cut-back asphalts, those liquids
which tend to form a surface film under test conditions and materials
which contain suspended solids.
Tag Closed Cup Flash Tester
• Conforms to ASTM D56 and related specifications
• Gas or electrical heating
Determines flash points of liquid products by the Tag Closed Cup method.
Features stepless variable heat control with reference dial for accurate
repeat setting of temperature rate of rise per specifications. Also available
with gas burner instead of electric heater. Precision machined cover
mechanism simultaneously opens slide shutter and applies test flame
to sample at the turn of a knob. Includes liquid bath with constant level
overflow, brass test cup, plated brass thermometer ferrules and test flame
reference bead. Bath and cover mechanism are constructed of plated
brass. Heater is enclosed in a cast aluminum base assembly.
Please refer to page 33 about our automated Tag Closed Cup Flash
Point Tester or inquire by contacting Koehler Customer Service.
Ordering Information
Catalog No.
Tag Closed Cup Flash Tester
K14600
Electrically Heated Model,
115V 60Hz
K14670
Electrically Heated Model,
220-240V 50/60Hz
K14690
Gas Heated Model
Order Qty
1
K14600 Tag Closed Cup Flash Tester
Specifications
Conforms to the specifications of:
ASTM D56; IP 304; FTM 791-1101
Electrical Requirements:
115V 60Hz, Single Phase, 1.3A
220-240V 50/60Hz, Single Phase, 0.6A
Accessories
250-000-09F
250-000-09C
250-000-57F
250-000-57C
K14510
K14520
ASTM 9F Thermometer
Range: 20 to 230°F
ASTM 9C Thermometer
Range: –5 to +110°C
ASTM 57F Thermometer
Range: –4 to +122°F
ASTM 57C Thermometer
Range: –20 to +50°C
Cover Assembly
Includes slide shutter burner and
thermometer ferrules
Brass Test Cup
Included Accessories
2
Brass Test Cup
Cover Assembly (includes Slide Shutter, Burner and Thermometer Ferrules)
Dimensions lxwxh,*in.(cm)
2
5x5x16 (13x13x41)
*with thermometers inserted
Net Weight: 7 lbs (3.2kg)
Shipping Information
Shipping Weight: 8 lbs (3.6kg)
Dimensions: 0.76 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
35
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 36
Flash and Fire Points by Cleveland Open Cup
Test Method
For flash and fire points of all petroleum products, except fuel oils and
those having an open cup flash below 79°C (175°F).
Cleveland Open-Cup Flash Tester
• Conforms to ASTM D92 and related specifications
• For flash points above 79°C (175°F)
Determines flash and fire points by the Cleveland Open-Cup method.
Consists of test flame applicator, brass test cup, thermometer support,
heating plate and electric heater. Applicator is precisely aligned per
specifications and pivots for test flame application at specified
temperature intervals. Hinged thermometer support raises to facilitate
placement and removal of test cup. Adjust flame size using built-in
needle valve and comparison bead.
Equipped with a 1000W nickel-chromium heater with stepless variable
heat control for accurate repeat setting of temperature rate of rise per
specifications.
Heater unit is enclosed in a stainless steel housing with cooling vents.
Test flame applicator and thermometer support are constructed of
machined nickel plated brass.
Please refer to page 33 about our automated Cleveland
Open Cup Flash Point Tester or inquire by contacting Koehler
Customer Service.
K13900 Cleveland Open Cup Flash Tester
Ordering Information
Specifications
Catalog No.
Cleveland Open-Cup Flash Tester
K13900
Electrically Heated Model,
115V 60Hz
K13990
Electrically Heated Model,
220-240V 50/60Hz
Conforms to the specifications of:
ASTM D92, D6074, D6158; AASHTO T48; ANS Z-11.6; IP 36; ISO 2592;
DIN 51376; FTM 791-1103, FTM 141-4294
Electrical Requirements:
115V 60Hz, Single Phase, 6.5A
220-240V, 50/60Hz, Single Phase, 3.4A
Included Accessories
Order Qty
1
Accessories
Brass Test Cup
250-000-11F
Dimensions lxwxh,in.(cm)
10x5 ⁄2x14 (25x14x36)
Net Weight: 81⁄2 lbs (3.9kg)
250-000-11C
Shipping Information
K14000
1
Shipping Weight: 12 lbs (5.4kg)
Dimensions: 1.5 Cu. ft.
ASTM 11F Thermometer
Range: 20 to 760°F
ASTM 11C Thermometer
Range: –6 to +400°C
Cleveland Open Flash Cup
Precision machined brass with heat resistant handle
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
36
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 37
Flash Point by Tag Open-Cup Apparatus
Flash Point and Fire Point of Liquids by
Tag Open-Cup Apparatus
Flash Point of Cutback Asphalt with
Tag Open-Cup Apparatus
Test Method
For determination of flash and fire points of liquids at temperatures of up to
325°F (163°C) and flash points of cutback asphalts at temperatures of less
than 200°F (93°C).
Tag Open-Cup Flash Tester
• Conforms to ASTM D1310, D3143 specifications
• Choice of gas or electrically heated
Determines Tag Open-Cup flash point of liquid products and cutback asphalts.
Includes sample test cup, plated brass liquid bath with constant level overflow,
pivoting ignition taper with pilot light and reference bead, pivoting
thermometer holder, heater and cast aluminum base.
Electrically heated model is equipped with stepless variable heat control for
accurate control of temperature rate of rise per specifications. Gas heated
model also available.
K15600 Tag Open-Cup Flash Tester
Ordering Information
Catalog No.
Tag Open-Cup Flash Tester
K15600
Electrically Heated Model,
115V 60Hz
K15670
Electrically Heated Model,
220-240V 50/60Hz
K15690
Gas Heated Model
Specifications
Order Qty
Conforms to the specifications of:
ASTM D1310, D3143
Electrical Requirements:
115V 60Hz, Single Phase, 13A
220-240V 50/60Hz, Single Phase, 0.6A
1
Included Accessories
Borosilicate Glass Sample Cup
Accessories
250-000-33F
250-000-33C
250-000-09F
250-000-09C
250-000-35F
250-000-35C
K15610
K15620
K15520
ASTM 33F Thermometer
Range: –36.5 to +107.5°F
ASTM 33C Thermometer
Range: –38 to +42°C
ASTM 9F Thermometer
Range: 20 to 230°F
ASTM 9C Thermometer
Range: –5 to +110°C
ASTM 35F Thermometer
Range: 194 to 338°F
ASTM 35C Thermometer
Range 90 to 170°C
Leveling Device
For proper adjustment of sample level in test cup.
Meets ASTM specifications. Polished aluminum
Draft Shield
Sample Cup
Dimensions lxwxh,*in.(cm)
1
10x7x17 (25x18x43)
*with thermometer inserted
Net Weight: 71⁄2 lbs (3.4kg)
1
Shipping Information
Shipping Weight: 91⁄2 lbs (4.3kg)
Dimensions: 1.3 Cu. ft.
1
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
37
0-31-40_3_FlashAA_Layout 1 11/26/12 3:49 PM Page 38
Flash Point and Sustained Burning of Liquids
Flash Point of Liquids by Small Scale
Closed Cup Apparatus
Flash Point by Small Scale Closed Tester
Sustained Burning of Liquid Mixtures by Setaflash
Tester (Open-Cup)
Test Method
Verifies the flash point or the sustained burning qualities of small samples
in the range of –30˚C to +300˚C.
Rapid Flash Tester
• Conforms to ASTM D3278, D3828, D4206; DOT CFR 49-173.115; IATA;
ISO 9038 and related specifications
• One minute test with a 2mL sample
• Simple to operate
Rapid Tester® provides rapid determinations of flash point or sustained
burning qualities by using a small sample. A flash/no flash test result is
achieved in one minute for flash points below 212˚F (100˚C) with a 2mL
sample. Ideally suited for quality assurance and environmental compliance
testing as well as actual flash point for paints, fragrances, hydrocarbons and
other liquids. Open cup models are used for determining sustained burning
qualities characteristics of mixtures of flammable and nonflammable liquids
or liquids with widely different flash points when assessing flammability
characteristics. Features convenient semi-automatic operation for flash/no
flash tests. Set the test temperature on the digital display and inject a 2mL or
4mL sample into the sample cup. The tester quickly stabilizes itself at the
desired value, permitting the test flame to be applied and the result to be
observed by the operator. Unit also performs conventional determinations of
actual flash temperature by the small scale closed tester method.
K16500 Rapid Flash Tester, Closed Cup
Ordering Information
Catalog No.
K16500
K16591
K16502
K16592
K16503
K16593
K16504
K16594
Rapid Flash Tester, Closed Cup, 115V
Aluminum Test Cup/Brass Lid & Shutter
Rapid Flash Tester, Closed Cup, 220-240V
Aluminum Test Cup/Brass Lid & Shutter
Rapid Flash Tester, Closed Cup, 115V
Stainless Steel Test Cup, Lid & Shutter
Rapid Tester, Closed Cup, 220-240V
Stainless Steel Test Cup, Lid & Shutter
Rapid Flash Tester, Open-Cup, 115V
Aluminum Test Cup
Rapid Flash Tester, Open-Cup, 220-240V
Aluminum Test Cup
Rapid Flash Tester, Open-Cup, 115V
Stainless Steel Test Cup
Rapid Flash Tester, Open-Cup, 220-240V
Stainless Steel Test Cup
Two models are offered: the Closed Cup Model is for routine flash point tests
in the range from –30 to +300˚C (–22 to +572˚F); the Open-Cup Model is for
sustained burning tests in the range from ambient to 212˚F (100˚C). Both
models include automatic temperature control with ˚C/˚F selector switch,
syringe, electronic timer, integral NIST traceable thermometer, and an external
fuel cylinder valve for connection to a customer-supplied fuel cylinder or other
fuel source.
Specifications
Accessories
K16506
K16507
K16508
K16509
K16510
K16511
K16512
K16513
K16514
K16515
K16516
K16517
Conforms to the specifications of:
ASTM D3278, D3828, D4206; IP 303; ISO 3679, ISO 3680, ISO 9038;
DOT CFR 49-173.115; IATA
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Fuel Cylinder Valve
Heat Transfer Compound for thermometer
Metal Cooling Block to facilitate cooling
of the sample cup between tests
Refrigerant Charged Cooling Block to hold cooling
mixture for subambient testing
Syringe 2mL/4mL
Thermometer, range 32 to 572˚F/0 to 300˚C
Thermometer, range 32 to 230˚F
Thermometer, range 212 to 572˚F
Thermometer, range 0 to 110˚C
Thermometer, range 100 to 300˚C
Thermometer, range –36 to +105˚F
Thermometer, range –38 to +40˚C
Included Accessories
Thermometer, range 32 to 572˚F (0 to 300˚C)
Syringe
Dimensions: lxwxh,in.(cm)
15x23.4x6.3 (38.1x8.6x16.2)
Net Weight: 10 lbs (4.6kg)
Shipping Information
Shipping Weight: 16 lbs (7.26kg)
Dimensions: 2.3 Cu. ft.
38
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 39
Autoignition Temperature of Liquid Chemicals
Test Method
Determines the lowest temperature at which the vapors of a liquid or solid
chemical sample will self-ignite under prescribed laboratory conditions.
The temperatures at which ‘cool flame’ and ‘hot flame’ ignitions occur,
as evidenced by sudden temperature increases in the sample flask, are
measured and recorded, and the delay time between introduction of the
sample and ignition is timed.
Autoignition Apparatus
• Conforms to ASTM E659 specifications
• Digital furnace temperature control
• Digital flask temperature display
Modified crucible furnace with digital thermocouple readout of flask temperature
at prescribed points per ASTM specifications. Linearized analog output
permits connection to a strip chart recorder or datalogging instrument. Furnace
provides rapid response and ±1°C stability throughout the operating range
from Ambient to 750°C. Cylindrical heating chamber provides excellent
radial temperature uniformity. Furnace cover has ports for flask exterior
K47000 Autoignition Apparatus
thermocouples, and a borosilicate glass thermocouple tube is provided to
assure correct positioning of the gas temperature thermocouple inside the test
flask. Thermocouples plug directly into the furnace control unit for quick
disconnection when removing the flask. A hinged holder in the cover facilitates
handling of the test flask. Adjustable mirror permits safe viewing of the flask
interior during testing. Control panel has temperature controls and digital Special apparatus for performing the Autoignition Test according to
thermocouple readout with four-position selector switch.
the ASTM D2155 test method is available. Please contact Koehler
Specifications
Customer Service for additional and ordering information.
Conforms to the specifications of:
ASTM E659
Temperature Range: Ambient to 750°C
Temperature Control: digital setpoint solid state controller
accurate to within ±1°C
Flask Temperature Display: 0-750°C, with four position selector switch
Electrical Requirements: 220-240V 50/60Hz, Single Phase, 7.7A
Ordering Information
Catalog No.
K47000
Autoignition Apparatus, 220-240V 50/60Hz
1
Accessories
Borosilicate Test Flask, 500mL
Thermocouples (4)
362-001-000
K470-0-1-14
K70015-1A
374-115-001
Dimensions lxwxh,in.(cm)
374-230-001
Furnace: 15x15x22 (38x38x56)
Control Cabinet: 22x10x14 (56x25x36)
Net Weight: 72 lbs (32.8kg)
332-003-008
Included Accessories
K470-0-1-8
Shipping Information
Shipping Weight: 98 lbs (44.5kg)
Dimensions: 16.3 Cu. ft.
39
Syringe, 1mL
Needle, 6", stainless steel
Recorder, 115V/230V 50/60Hz
Hot Air Gun, 115V 60Hz
For purging product gases between tests
Hot Air Gun, 220-240 50/60Hz
For purging product gases between tests
Quartz Test Flask, 500mL
For high temperature testing over 600˚C
Quartz Thermocouple Guide
1
1
1
1
0-31-40_3_Flash_Layout 1 10/24/12 10:58 AM Page 40
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Flash Point by Pensky-Martens Closed Tester.................Pages 32, 34
ASTM D93, AASHTO T73-811, IP 34, ISO 2719, DIN 51758, FTM 791-1102
Propane
Toluene
Acetone
Calcium Chloride
Barometer
Flash Point by Tag Closed Tester ......................................Pages 33, 35
ASTM D56, IP 304, FTM 791-1101
Ethylene Glycol
Propane
Barometer
Water
Flash and Fire Points by Cleveland Open-Cup ................Pages 33, 36
ASTM D92, AASHTO T48, ANS Z-11.6. IP 36, ISO 2592, DIN 51376,
FTM 791-1103, FTM 141-4294
Barometer
Flash Point of Cutback Asphalt with
Tag Open-Cup Apparatus ...........................................................Page 33
ASTM D3143
Ethylene Glycol
Distilled Water
Flash Point and Fire Point of Liquids by
Tag Open-Cup Apparatus ...........................................................Page 37
ASTM D1310
Flasks, 500mL (2)
Distilled Water
Solid Carbon Dioxide
Acetone
n-Heptane
p-Xylenol
Isopropanol
Diethylene Glycol
Autoignition Temperature of Liquid Chemicals.......................Page 39
ASTM E659
Laboratory Balance
Powder Funnel
40
0-41-53_4a_GTE_Layout 1 10/24/12 11:00 AM Page 41
General Test Equipment
Test Methods
Page
Aniline Point and Mixed Aniline Point of Petroleum Products and
Hydrocarbon Solvents ASTM D611; IP 2; ISO 2977; DIN 51775;
FTM 791-3601 ................................................................................42-43
Saybolt Color of Petroleum Products
ASTM D156; DIN 51411; FTM 791-101........................................44, 46-47
ASTM Color of Petroleum Products
ASTM D1500, D6074; IP 196; ISO 2049; FTM 791-102 ......................45-46
Visual Examination of Used Electrical Insulating Oils
of Petroleum Origin in the Field ASTM D1524 ............................................45
Automated Colorimeter ASTM D156, D1209, D1544, D1925, D6166; ISO
2049, 4630, 6271; DIN 5033, 6162, 6174; AOCS CC 13E; USP CH 631,
1061; PH EUR; NF M 07-003; NF T 60-104 ............................................47
Density, Relative Density (Specific Gravity), or API Gravity of Crude
Petroleum and Liquid Petroleum Products by Hydrometer Method
ASTM D287, D1298, D6074, D6159, E100; API MPMS Chapters 9.1;
IP 60; ISO 3675; DIN 51757..............................................................48-50
Water in Oils/Gas/Powders by Coulometric Karl Fischer Titration
ASTM D1533, D4928, D6304; IP 386; API Chapter 10.9 ..........................51
Automatic Flocculation Titrimeter ................................................................52
Distillation of Petroleum Products at Reduced Pressures
ASTM D1160; ISO 6616....................................................................53-54
Distillation of Petroleum Products
ASTM D86, D216, D233, D447, D850, D1078, E133; IP 123, 195;
ISO 3405; DIN 51751; FTM 791-1001, 791-1015..........................................55
Automatic Distillation System
ASTM D86, D285, D850, D1078; ISO 3405; DIN 51751; IP 123 ..........56-57
Sulfur in Liquefied Petroleum Gases (Oxy-Hydrogen Burner) ASTM D2384,
D2747, D2784, D2785-80; GPA 2140; IP 243; ISO 4260; DIN EN41..........58
Traces of Volatile Chlorides in Butane-Butene Mixtures ASTM D2384 ....58
Trace Quantities of Total Sulfur (Wickbold Apparatus) ASTM D2785 ......58
Sulfur in Petroleum Products (Wickbold Apparatus) IP 243....................58
Ramsbottom Carbon Residue of Petroleum Products
ASTM D524, D6074; IP 14; ISO 4262; FTM 791-5002 ............................59
Lead in Gasoline by Volumetric Chromate Method
ASTM D2547; IP 77, 182, 248; ISO 2083................................................60
Acidity (Inorganic) of Petroleum Products by Color
Indicator Titration Method IP 182 ........................................................60
Test Methods
Page
Salt Content of Crude Petroleum and Products IP 77..............................60
Conradson Carbon Residue of Petroleum Products ASTM D189,
D6074; ANS Z-11.25; IP13; ISO 6615; DIN 51551; FTM 791-5001 ..........60
Sediment in Crude Oils and Fuel Oils by Extraction Method
D473; IP 53; ISO 3735; DIN 51789; FTM 791-3002 ................................61
Salts in Crude Oil (Electrometric Method) ASTM D3230 ........................61
Water and Sediment in Crude Oils and Fuel Oils (Centrifuge Method)
ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007; IP 75,
145, 359; API 2542, 2548; ISO 3734; DIN 51793 ....................................62
Water and Sediment in Crude Oils by Centrifuge
ASTM D96; API 2542; IP MPMS CHAPTER 10.4 ....................................63
Ash from Petroleum Products................................................................63
Automatic Density Meter
ASTM D1250, D4052, D5002; DIN 51757 ..............................................64
Rust Protection by Metal Preservatives in the Humidity Cabinet
ASTM D1748, FTM 791-5310 ................................................................65
Sampling of Petroleum and Petroleum Products
ASTM D4057, D1265, D6074; GPA 2140 ..........................................66-67
Sampling Liquefied Petroleum (LP) Gases
ASTM D1265 and GPA 2140 ............................................................66-67
Freezing Point of Aqueous Engine Coolant Solution ASTM D1177..........68
Color of Maleic and Phthalic Anhydrides ASTM D3366 ..........................68
Automatic Melting Point Range Apparatus BP Appendix 5-Method 6; GLP....69
General Purpose Baths ....................................................................70-71
Water in Petroleum Products and Bituminous Materials by Distillation
ASTM D95, E123, D244, D370; AASHTO T55, T59; API MPMS CH. 10.5;
IP 74, 291; FTM 791-3001; ISO 3733 ....................................................72
General Purpose Utility Heater..............................................................72
Refractive Index and Refractive Dispersion of Hydrocarbon Liquids
ASTM D1218, D1747 ............................................................................73
Calibration of Liquid-in-Glass Thermometers NBS Monograph 150........74
pH / Conductivity Meters ......................................................................74
Automatic Titrator ASTM D664, D2896, D3227, D4739 ..........................75
Automatic Calorimeter..........................................................................76
Automatic Filter Plugging Tendency Analyzer ASTM D2068 ..................76
Oxidation Stability of Foods, Oils, Fats, and Biodiesel Fuels ................77
www.koehlerinstrument.com
0-41-53_4a_GTE_Layout 1 10/24/12 11:00 AM Page 42
Aniline Point and Mixed Aniline Point of Petroleum Products
Aniline Point and Mixed Aniline Point of Petroleum
Products and Hydrocarbon Solvents
Test Method
Aniline point is used to characterize pure hydrocarbons and to indicate the
aromatic content of hydrocarbon mixtures. Equal volumes of aniline and
sample or sample plus n-heptane are stirred together while being heated
at a controlled rate. After the two phases become miscible, the mixture is
cooled at a controlled rate and the temperature at which the two phases
separate is the aniline point or mixed aniline point of the sample.
Automatic Aniline Point Apparatus
•
•
•
•
Performs aniline point and mixed aniline point determinations automatically
by means of a modified thin film technique (ASTM D611 Method E). The
sample-aniline mixture is directly heated by a platinum immersion heater
and the aniline point is detected photoelectrically. Temperature is displayed
on a large LED indicator. Built-in pressure regulator and solenoid valve
permit the use of cooling air for quicker cooling cycles or to determine
subambient aniline point temperatures. Aniline points as low as 0°C (32°F)
can be determined with the use of refrigerated cooling air. Equipped with
variable controls for heater, light source and stirrer speed. Cabinet exterior
surfaces have a chemical resistant polyurethane enamel finish.
K10200 Automatic Aniline Point Apparatus
Specifications
Ordering Information
Catalog No.
K10200
K10290
Conforms to the specifications of:
ASTM D611; IP 2; ISO 2977; DIN 51775; FTM 791-3601; NF M 07-021
Testing Range: 0 to 150°C (32 to 302°F)
Temperature Display: 0-999.9°C
Electrical Requirements:
115V 60Hz, Single Phase, 0.4A
220-240V 50/60Hz, Single Phase, 0.2A
Order Qty
Automatic Aniline Point Apparatus,
115V 60Hz
Automatic Aniline Point Apparatus,
220-240V 50/60Hz
1
Accessories
250-000-33F
250-000-33C
250-000-34F
250-000-34C
250-000-35F
250-000-35C
K10210
K10220
ASTM 33F Thermometer
Range: –36.5 to +107.5°F
ASTM 33C Thermometer
Range: –38 to +42°C
ASTM 34F Thermometer
Range: 77 to 221°F
ASTM 34C Thermometer
Range: 25 to 105°C
ASTM 35F Thermometer
Range: 194 to 338°F
ASTM 35C Thermometer
Range: 90 to 170°C
Borosilicate Glass Test Cell with drain
Heating-Cooling Tube with platinum element
Conforms to ASTM D611 and related specifications
For samples ranging from clear to very dark
Temperature range 0°C to 150°C (32°F to 302°F)
Digital temperature display
Included Accessories
Standard Borosilicate Glass Test Cell with drain
1
Dimensions Ixwxh,in.(cm)
141⁄2x81⁄2x203⁄4 (37x22x53)
Net Weight: 321⁄2 lbs (14.7kg)
1
Shipping Information
Shipping Weight: 46 lbs (21kg)
Dimensions: 8.2 Cu. ft.
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
42
0-41-53_4a_GTE_Layout 1 10/24/12 11:01 AM Page 43
Aniline Point and Mixed Aniline Point of Petroleum Products
Thin Film Aniline Point Apparatus
• Conforms to ASTM D611 and related specifications
For aniline point and mixed aniline point determinations according to Method
B. Stirs aniline-sample mixture in a borosilicate glass thin film tube suspended
in a heating bath. Thin film of mixture flows over a light well illuminated by a
variable 6V lamp. Adjust heating rate per specifications using accessory
Powertrol Heater. When lamp filament brightens inside well, allow mixture to
cool until the two phases separate as indicated by obscuring of the lamp
filament. Consists of thin film tube; 400mL Borosilicate Glass beaker; cover
assembly with bath stirrer; sample pump rotor and cooling coil; 6V lamp with
line cord; and drive motor. Positive drive pulley system rotates sample and
bath stirrers. Accessory Powertrol Heater has variable stepless control and a
reference dial for repeatable control of heating rate. Porcelain refractory top
plate shields 1000W heater and has a positioning well for the Borosilicate
Glass bath. Low voltage receptacle in heater housing accepts line cord of 6V
lamp.
Specifications
Conforms to the specifications of: ASTM D611; IP 2; ISO 2977;
DIN 51775; FTM 791-3601; NF M 07-021
Bath Medium: 400mL of heat transfer fluid
(355-001-001 mineral oil is suitable for this application)
Electrical Requirements:
115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase, 13.4A
Included Accessories
Thermometer Ferrules (2)
Clamps and Support Rod
Dimensions Ixwxh,in.(cm)
Shipping Information
141⁄2x181⁄2x203⁄4 (37x22x53)
Net Weight: 24 lbs (10.9kg)
Shipping Weight: 42 lbs (19.1kg)
Dimensions: 5.7 Cu. ft.
K10190 Thin Film Aniline Point Apparatus
Ordering Information
Catalog No.
K10190
K10191
K10020
K10029
U-Tube Aniline Point Apparatus
Order Qty
Thin Film Aniline Point Apparatus,
115V 60Hz
Thin Film Aniline Point Apparatus,
220-240V 50/60Hz
Powertrol Heater, 115V 60Hz
Powertrol Heater, 220-240V 50/60Hz
• Developed by Standard Inspection Laboratories
Similar to the Thin Film Aniline Point Apparatus but with ‘U-Tube’
aniline-sample tube and stirrer as developed by Standard Inspection
Laboratories. Suitable for samples having 6.5 or lighter ASTM D1500 color. As
illustrated in IP2-56, Method D. Consists of U-tube; 400mL Borosilicate Glass
beaker; cover assembly with bath stirrer; sample stirrer and cooling coil; 6V
lamp with line cord; and drive motor. Thermometer ferrules and mounting
hardware are included. Accessory Powertrol Heater provides variable stepless
control of heating rate and 6V tap for lamp.
1
1
Accessories
250-000-33F
250-000-33C
250-000-34F
250-000-34C
250-000-35F
250-000-35C
ASTM 33F Thermometer
Range: –36.5 to +107.5°F
ASTM 33C Thermometer
Range: –38 to +42°C
ASTM 34F Thermometer
Range: 77 to 221°F
ASTM 34C Thermometer
Range: 25 to 105°C
ASTM 35F Thermometer
Range: 194 to 338°F
ASTM 35C Thermometer
Range: 90 to 170°C
2
Ordering Information
Catalog No.
K10090
2
K10091
K10020
2
K10029
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
43
Order Qty
U-Tube Aniline Point Apparatus
115V 60Hz
U-Tube Aniline Point Apparatus
220-240V 50/60Hz
Powertrol Heater,
115V 60Hz
Powertrol Heater,
220-240V 50/60Hz
1
1
0-41-53_4a_GTE_Layout 1 10/24/12 11:01 AM Page 44
Saybolt Color of Petroleum Products
Test Method
The Saybolt Color test is used for quality control and product identification
purposes on refined products having an ASTM Color of 0.5 or less. Products
in this range include undyed motor and aviation gasolines, jet propulsion
fuels, naphthas, kerosene and petroleum waxes. Color is an important
quality characteristic for many products, and can also be used to detect
product contamination. The Saybolt Chromometer measures color by
comparing a column of sample against standard color discs. The Saybolt
Wax Chromometer measures color of non-fluid waxes by heating the
samples during the test.
Saybolt and Saybolt Wax Chromometers
• Conforms to ASTM D156 and related specifications
• Three-position color standard turret
• Tests non-fluid waxes and liquid petroleum products
Determines Saybolt Color of highly refined petroleum products. Consists
of a matched set of sample and standard tube assemblies with optical
viewer. Compares a sample of the product to be tested against standard
color discs under a uniform light source. Reduce column height until the
sample field is lighter than the color standard and convert height to
Saybolt Color using chart on instrument. Three-position turret on
standard tube permits convenient changing of color disc combinations.
Accessory Daylight Lamp (Cat. No. K13010) provides standard light
source per ASTM specifications.
For petroleum waxes, the Saybolt Wax Chromometer is equipped with
heaters to keep waxes that are not fluid at ambient temperature molten
during testing. Sample tube has a 200W chrome steel strip heater and a
hinged cover to maintain even heat distribution. An aluminum block
heater with 50W cartridge element keeps wax molten in the draincock
assembly. Accessory variable transformer may be used to regulate the
sample temperature. Optical viewer and stand are fully insulated from the
heaters. Sample tube assembly has heat resistant fiber handles.
Ordering Information
K13009 Saybolt Chromometer
Catalog No.
K13009
K13100
K13190
Specifications
Conforms to the specifications of:
ASTM D156; DIN 51411; FTM 791-101; NF M 07-003
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
K13020
K13029
K13032
Whole Color Standards (3)
Half Color Standard (1)
Engraved Conversion Chart
K13033
Dimensions lxwxh,in.(cm)
5 ⁄2x5 ⁄2x26 ⁄2 (14x14x67)
Net Weight: 151⁄2 lbs (7kg)
1
1
1
Accessories
K13010
Included Accessories
1
Saybolt Chromometer
Saybolt Wax Chromometer, 115V 60Hz
Saybolt Wax Chromometer, 220-240V 50/60Hz
1
279-115-005
279-230-002
Shipping Information
Shipping Weight: 31 lbs (14.1kg)
Dimensions: 4.0 Cu. ft.
Includes accessory lamp
44
Daylight Lamp
1
Meets ASTM D156 and related test specifications for
illumination of Saybolt Chromometers. Adjustable for
correct positioning. Standard 60W bulb not included.
Whole Color Standard
Half Color Standard
Matched Set of Tubes with Turret
Assembly for K13009 Saybolt Chromometer
Matched Set of Tubes with Turret and Draincock
Assembly for K13100/K13190 Saybolt Wax Chromometer
Frosted Bulb, 60W, 115V
1
Frosted Bulb, 60W, 220-240V
0-41-53_4a_GTEaa_Layout 1 11/5/12 11:24 AM Page 45
ASTM Color of Petroleum Products
Test Method
The ASTM color of petroleum products applies to products having an
ASTM color of 0.5 or darker, including lubricating oils, heating oils and
diesel fuel oils. (For products having an ASTM color lighter than 0.5,
use the Saybolt Chromometer.) To determine ASTM color, the sample
is compared against standard color discs in the Petroleum Colorimeter.
Petroleum Colorimeter
•
Conforms to ASTM D1500 specifications
Single scale, 3-field petroleum comparator designed for visual color
grading by direct comparison between the sample and colored glass filters
housed in test discs conforming to the chromaticity coordinates of ASTM
D1500. The sample and two consecutive glasses on the color scale are
viewed simultaneously, making it easier to achieve the optimum color
match. For rapid color grading within predetermined color limits, the glass
standards can be set to the two limiting colors so that it is easy to check
that the sample is within tolerance. The tungsten halogen light source
is color corrected to CIE Standard Illuminant C, giving constant lighting
conditions for color grading, regardless of ambient lighting. A prism brings
the three fields together to aid color grading.
K13200 Petroleum Colorimeter with
K13210 Sample Containers (3 Included)
Specifications
Conforms to the specifications of:
ASTM D1500, D6074; IP 196; ISO 2049; FTM 791-102
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Ordering Information
n
Catalog No.
K13200
K13290
Included Accessories
Glass Color Discs (2)
Sample Container (3)
Order Qty
Petroleum Colorimeter,
115V 60Hz
Petroleum Colorimeter,
220-240V 50/60Hz
Calibration Certificate
Dimensions dxwxh,in.(cm)
Shipping Information
10.5x9x5 (25x27x18)
Net Weight: 3.5 lbs (1.6kg)
Shipping Weight: 5.5 lbs (2.5kg)
Dimensions: 2.5 Cu. ft.
1
Accessories
K13210
K13223
Sample Container
Replacement Tungsten Halogen Lamp, 12V 20W
Visual Examination of Used Electrical Insulating Oils
Visual Examination of Used Electrical Insulating Oils of
Petroleum Origin in the Field
Shipping Information
Shipping Weight: 10 lbs (4.5kg)
Dimensions: 1 Cu. ft.
Test Method
Ordering Information
n
Provides an estimate of the color and condition of in-service oils by visual
observation and comparison with ASTM color standards in an oil comparator.
Catalog No.
K13203
Oil Comparator
Oil Comparator
Order Qty
1
Accessories
•
Conforms to ASTM D1524 specifications
• Yields results equivalent to ASTM D1500
Complete ASTM oil color test outfit for comparison of oils against ASTM color
standards. Includes two color discs, ranging from 0.5 to 5.0 in 10 steps and
5.0 to 8.0 in 7 steps. Magnifying prism brings the sample and standard color
fields together for side by side comparison. Portable unit is suitable for
laboratory or field use. Supplied with two precision 33mm rectangular glass
cells, carrying case and instructions.
K13204
K13294
K13205
45
Daylight Illuminator, 115V
Provides uniform lighting for Oil Comparator
Daylight Illuminator, 220-240V
Rectangular Glass Cell
1
0-41-53_4a_GTE_Layout 1 10/24/12 11:01 AM Page 46
Portable Automated Colorimeter
Portable Automated Colorimeter
• Conforms to ASTM D156, D1544, D1209, DIN 6162, and related
international test specifications
• Measures the 4 most important color scales used for liquid chemicals,
resins, oils, fuels, and fats for liquid color measurement
• Portable design for remote applications
Single-beam filter colorimeter system utilizes reference beam path technology
to measure samples over eight spectral wavelengths ranged between 400 and
700nm in comparison to 4 standard color scales. Provides photometric high
precision color measurements that are objective, accurate, and consistent over
a wide variety of samples required for quality control programs.
Measurements are initiated by just a single key press and require less than one
minute to complete. The test results can be either displayed on the LCD screen
or sent to an external printer. Please contact Koehler Customer Support for
assistance on additional accessories required for your application.
Color Ranges
• Saybolt Color (ASTM D156, NF M 07-003)
K13260 Portable Automatic Colorimeter with
• Iodine Color (DIN 6162)
K13351 Cylindrical Cuvette and K13353 Rectangular Cuvettes (Both Sold Separately)
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
ASTM D156, D1209,
D1544, D6045; ISO 4630, 6271;
DIN 6162; NF M 07-003;
NF T 60-104; JIS K2580
Reproducibility: ±0.2% T
(referenced to distilled water)
Reference Standard: distilled water
Data Output: RS232/printer
Light Source: krypton lamp
7.9x10x3.5 (20x26x90)
Net Weight: 2.9 lbs (1.3kg)
• Hazen Color, APHA Color, Pt/Co Color (ASTM D1209, ISO 6271)
• Gardner Color (ASTM D1544, ISO 4630)
Ordering Information
Catalog No.
K13260
Shipping Information
Portable Automatic Colorimeter
Shipping Weight: 10 lbs (4.5kg)
Accessories
K13551
Electrical Requirements
115-240V 50/60Hz
K13550-1
Starter Kit – Consists of Addista Color Standards;
50 x 10 Rectangular Cuvettes, Pk/10; Cuvette Set,
10 x 11mm round glass cuvettes
Thermal Printer with USB Connection
Automated Colorimeter for Saybolt and ASTM Color
Saybolt and Mineral Oil Colorimeter
• Conforms to ASTM D156, D1500, D6045, and related test specifications
• Designed for color measurement of waxes and other petroleum products
High precision spectrophotometer for objective color analysis of petroleum
fuels, oils, waxes and petrochemicals according to the Saybolt and ASTM
Color scales. Test results can also be displayed in terms of CIE values and
spectral data. The colorimeter is rugged with a fabricated steel housing which
is designed to function equally as a QC instrument within the laboratory or on
24 hour operation in a production environment. A diagnostic test routine
allows users to conduct periodic checks on the instrument or to identify faults.
Direct access of the precision filament lamp from outside the instrument
allows for easy replacement. The colorimeter is also supplied with a colored
glass filter of known Saybolt value for regular conformance testing. Equipped
with integrated heater unit for melting solid samples such as fats and waxes
and preventing from solidification within the cell during testing.
K13150 Automated Colorimeter
Specifications
Conforms to the specifications of:
ASTM D156, D1500, D6045,
E 308; JIS K2580; ISO 2049;
NF M 07-003
Reproducibility: ±0.25% T,
±1 Saybolt value
Spectral Range: 410-710 nm
Data Output: RS232/printer
Light Source: tungsten halogen lamp
Illuminant: CIE Illuminant C
Observer: 2°
Electrical Requirements
115-240V 50/60Hz
Dimensions lxwxh,in.(cm)
Shipping Information
7.7x20.3x6.7 (19.5x51.5x17)
Net Weight: 17 lbs (7.75kg)
Shipping Weight: 23 lbs (10.5kg)
Ordering Information
Catalog No.
K13150
46
Automatic Saybolt and ASTM Colorimeter,
115-240V 50/60 Hz
0-41-53_4a_GTE_Layout 1 10/24/12 11:01 AM Page 47
Automated Colorimeter
Automated Colorimeter
• Touch-screen TFT-Color Display
• Automatic cuvette recognition
• Data log for 500 color values, 50 color reference values, 500 photometric
readings, 20 wavelength scans, 20 time scans
• Automatic zero calibration program
• Reference Beam Technology
• Password protection, GLP documentation
• USB-Ports: 1 x Type A and 1 x Type B
High performance, microprocessor controlled spectrophotometer with
a wavelength range from 380 to 720 nm for color measurement or 320 nm
up to 1100 nm for routine analysis. The K13550 can carry out an exact
colorimetric evaluation in conformity with several ISO/ASTM standards with
just a single measurement and display the result in terms of traditional color
systems such as Iodine, Hazen/APHA or Gardner color numbers as well
as in modern CIE-L*a*b* color values. Besides the over 20 color indexes,
transmittance and absorbance can be measured at individual wavelengths, so
that the K13550 can be used universally for analytical purposes in the laboratory.
K13550 Automatic Colorimeter with K13351 Cylindrical Cuvettes and K13353
Rectangular Cuvette (Both Sold Separately)
Color measurement methods:
•
•
•
•
•
•
Included Accessories:
Iodine, Hazen, APHA, Pt/Co, Gardner-Color
Saybolt, Klett-color
Hess-Ives, ADMI, Yellowness-index
AOCS-Red/Yellow, Chlorophyll A
CIE-Lab, Hunter-Lab, XYZ
European and US Pharmacopoeia
• Universal power supply 100-240V, 50-60 Hz, with exchangeable
plug adapters for EU, GB, US, China
• Dust Cover
• User Manual
Specifications
Photometer methods:
Conforms to the specifications of:
ASTM D156, D1209, D1544, D1925, D5386, D6045, D6166; ISO 4630,
6271; DIN 5033, 6162, 6174; AOCS Cc 13e; USP Ch 631, 1061; Ph EUR;
NF M 07-003; NF T 60-104
Spectral Bandwidth: 5 nm
Wavelength Reproducibility: 0.1nm
Wavelength Resolution: 1nm
Scanning Speed: 12 nm/s (in steps of 1 nm)
Stray Light: < 0.1% T at 340 nm with NaNO2
Color Measurement: 380-720nm in steps of 10nm
Wavelength Range: 320-1100nm in steps of 1nm
Wavelength Accuracy: +/- 1.5 nm (wavelength range 340-900 nm)
Photometric Measuring Range: +/- 3.5 Abs (wavelength range 340-900 nm)
Photometric Accuracy: 5 m Abs at 0.0 to 0.5 Abs
1% at 0.50 to 2.0 Abs
Photometric linearity: < 0.5% to 2 Abs
1% at > 2 Abs with neutral glass at 546 nm
Light Source: Gas-filled Tungsten (visible)
• Wavelength Scan 320-1100nm incl. Difference Mode
• Time Course Mode
• Single and Multi Wavelength Mode
Ordering Information
Catalog No.
K13550
Automatic Colorimeter 115-240V, 50/60 Hz
Accessories
K13551
Starter Kit
Consists of Addista Color Standards; 50 x 10 Rectangular
Cuvettes, Pk/10; Cuvette Set, 10 x 11mm round glass cuvettes
K13552
USB-Barcode Scanner (hand-held scanner)
K13553
Test filter set for stray light, absorbance and wavelength check
K13554
USB-Keyboard (keyboard layout: US)
K13253
Certified Testing solution set “Addista-Color”
K13351
Round cuvettes 11mm, glass, disposable, pk/500
K13353
Rectangular cuvette 50 x 10mm, plastic, disposable, pk/50
K13349
Rectangular cuvette 50 x 10mm with caps, plastic,
disposable, pk/10
K13250-1 Rectangular cuvette 50 x 10, glass, pk/1
K13500-3 Rectangular cuvette 10 x 10, glass, pk/3
K13550-1 Printer for K13550
K13356
Rack for 7 50x10 cuvettes
Dimensions lxwxh,in.(cm)
14.5 x 14.1 x 5.7 (36.8 x 35.9 x 14.4)
Net Weight: 14.11 lbs (6.4 kg)
Shipping Information
Shipping Weight: 18 lbs (8.2 kg)
Dimensions:20x16x16in.
Please use the K13250-1 Rectangular cuvette 50 x 10, glass, pk/1 or K13500-3
Rectangular cuvette 10 x 10, glass, pk/3 when testing hydrocarbons for color
measurements. The disposable polycarbonate cuvettes are made for aqueous
samples. Please ask you Koehler Sales Representative for details.
Electrical Requirements
115-240V, 50/60 Hz
47
0-41-53_4a_GTE_Layout 1 10/24/12 11:01 AM Page 48
Density, Relative Density (Specific Gravity), or API Gravity
Density, Relative Density
(Specific Gravity),
or API Gravity of Crude Petroleum and
Liquid Petroleum Products by
Hydrometer Method
API Gravity Hydrometers
Standard temperature 60°F, subdivisions, 0.1° API,
length 330mm
Catalog No.
251-000-21H
251-000-22H
251-000-23H
251-000-24H
251-000-25H
251-000-26H
251-000-27H
251-000-28H
251-000-29H
251-000-30H
251-000-31H
251-000-32H
251-000-33H
251-000-34H
251-000-35H
251-000-36H
251-000-37H
251-000-38H
251-000-39H
251-000-40H
ASTM Hydrometers
For density, relative density (specific gravity) or API gravity
determination of crude petroleum, liquid petroleum products
and mixtures of petroleum and non-petroleum products. For
density of LPG and light hydrocarbons refer to page 103.
Specifications
Conforming to the specifications of: ASTM E100
Applicable Test Method Standards:
ASTM D287, D1298, D6074, D6158;
API MPMS Chapter 9.1; IP 160; ISO 3675; DIN 51757
API Gravity Hydrometers
Standard temperature 60°F, subdivisions 0.1° API,
length 330mm
Catalog No.
251-000-01H
251-000-02H
251-000-03H
251-000-04H
251-000-05H
251-000-06H
251-000-07H
251-000-08H
251-000-09H
251-000-10H
ASTM
Hydrometer
No.
1H
2H
3H
4H
5H
6H
7H
8H
9H
10H
Nominal
API Gravity
Range, deg.
–1 to +11
9 to 21
19 to 31
29 to 41
39 to 51
49 to 61
59 to 71
69 to 81
79 to 91
89 to 101
Standard temperature 60°F, subdivisions 0.1° API, length
380mm, thermometer scale °F 0-150 (designation L),
30 to 180 (designation M), 60 to 220 (designation H)
Catalog No.
251-000-51HH
251-000-51HL
251-000-52HH
251-000-52HL
251-000-53HM
251-000-53HL
251-000-54HM
251-000-54HL
251-000-55HL
251-000-56HL
251-000-57HL
251-000-58HL
251-000-59HL
251-000-60HL
Standard temperature 60/60°F, subdivisions 0.0005,
length 330mm
Catalog No.
251-000-82H
251-000-83H
251-000-84H
251-000-85H
251-000-86H
251-000-87H
251-000-88H
251-000-89H
251-000-90H
Nominal
API Gravity
Range, deg.
0 to 6
5 to 11
10 to 16
15 to 21
20 to 26
25 to 31
30 to 36
35 to 41
40 to 46
45 to 51
50 to 56
55 to 61
60 to 66
65 to 71
70 to 76
75 to 81
80 to 86
85 to 91
90 to 96
95 to 101
API Gravity Thermohydrometers Thermometer in Body
Specific Gravity Hydrometers
ASTM
Hydrometer
No.
82H
83H
84H
85H
86H
87H
88H
89H
90H
ASTM
Hydrometer
No.
21H
22H
23H
24H
25H
26H
27H
28H
29H
30H
31H
32H
33H
34H
35H
36H
37H
38H
39H
40H
Nominal
Specific Gravity
Range
0.650 to 0.700
0.700 to 0.750
0.750 to 0.800
0.800 to 0.850
0.850 to 0.900
0.900 to 0.950
0.950 to 1.000
1.000 to 1.050
1.050 to 1.100
ASTM
Thermohydrometer
No.
51HH
51HL
52HH
52HL
53HM
53HL
54HM
54HL
55HL
56HL
57HL
58HL
59HL
60HL
Nominal
API Gravity
Range, deg.
–1 to 11
–1 to 11
9 to 21
9 to 21
19 to 31
19 to 31
29 to 41
29 to 41
39 to 51
49 to 61
59 to 71
69 to 81
79 to 91
89 to 101
API Gravity Thermohydrometers Thermometer in Stem
Standard temperature 60°F, subdivisions 0.1° API,
length 380mm, temperature scale °F 30-220
Calibrated hydrometers and thermohydrometers are available
from Koehler with an ISO/IEC 17025 and ANSI/NCSL Z-540-1
Report of Calibration.
When inquiring about calibrated hydrometers and thermohydrometers,
please refer to the catalog number for the corresponding hydrometer/
thermohydrometer and replace the middle three zeros in the catalog
number with 004. Example: 251-000-01H API Gravity Hydrometer would
be 251-004-01H Certified API Gravity Hydrometer.
Catalog No.
251-000-71H
251-000-72H
251-000-73H
251-000-74H
48
ASTM
Thermohydrometer
No.
71H
72H
73H
74H
Nominal
API Gravity
Range, deg.
–1 to 11
9 to 21
19 to 31
29 to 41
0-41-53_4a_GTE_Layout 1 10/24/12 11:01 AM Page 49
Density, Relative Density (Specific Gravity), or API Gravity
Specific Gravity Hydrometers
Hydrometer Cylinders*
Standard temperature 60/60°F, subdivisions 0.001 length 260mm
• Wide base for maximum stability
• Convenient pour-out lip
• Choice of glass or metal construction
Catalog No.
251-000-102H
251-000-103H
251-000-104H
251-000-105H
251-000-106H
251-000-107H
251-000-108H
251-000-125H
251-000-126H
251-000-127H
251-000-128H
251-000-129H
251-000-130H
251-000-131H
251-000-132H
251-000-133H
251-000-134H
251-000-135H
251-000-136H
251-000-137H
251-000-138H
251-000-139H
251-000-140H
251-000-141H
ASTM
Hydrometer
No.
102H
103H
104H
105H
106H
107H
108H
125H
126H
127H
128H
129H
130H
131H
132H
133H
134H
135H
136H
137H
138H
139H
140H
141H
Nominal
Specific Gravity
Range
0.650 to 0.700
0.700 to 0.750
0.750 to 0.800
0.800 to 0.850
0.850 to 0.900
0.900 to 0.950
0.950 to 1.000
1.000 to 1.050
1.050 to 1.100
1.100 to 1.150
1.150 to 1.200
1.200 to 1.250
1.250 to 1.300
1.300 to 1.350
1.350 to 1.400
1.400 to 1.450
1.450 to 1.500
1.500 to 1.550
1.550 to 1.600
1.600 to 1.650
1.650 to 1.700
1.700 to 1.750
1.750 to 1.800
1.800 to 1.850
ASTM Metric Thermohydrometers
K26300 Brass Hydrometer Cylinder
Standard temperature 15°C, subdivisions 0.5kg/m3, length 380mm,
thermometer scale °C: –20 to +65 (designation L), 0 to 85 (designation M),
20 to 105 (designation H).
Catalog No.
251-000-300HL
251-000-301HL
251-000-302HL
251-000-302HM
251-000-303HL
251-000-303HM
251-000-304HL
251-000-304HM
251-000-305HL
251-000-305HM
251-000-306HL
251-000-306HM
251-000-307HL
251-000-307HH
251-000-308HH
251-000-308HL
251-000-309HH
251-000-309HL
ASTM
Thermohydrometer
No.
300HL
301HL
302HL
302HM
303HL
303HM
304HL
304HM
305HL
305HM
306HL
306HM
307HL
307HH
308HH
308HL
309HH
309HL
Ordering Information
Catalog No.
K26300
Density, Range
kg/m3
600 to 650
650 to 700
700 to 750
700 to 750
750 to 800
750 to 800
800 to 850
800 to 850
850 to 900
850 to 900
900 to 950
900 to 950
950 to 1000
950 to 1000
1000 to 1050
1000 to 1050
1050 to 1100
1050 to 1100
Construction
Brass
K26390
Brass
332-002-011
Glass
Dimensions
dia.xh.
21⁄2 x12"
(64x305mm)
2x15"
(51x381mm)
2x151⁄2"
(51x394mm)
*Not suitable for use with K26400 series baths
Calibrated hydrometers and thermohydrometers are available from Koehler
with an ISO/IEC 17025 and ANSI/NCSL Z-540-1 Report of Calibration.
When inquiring about calibrated hydrometers and thermohydrometers, please refer to the
catalog number for the corresponding hydrometer/thermohydrometer and replace the middle
three zeros in the catalog number with 004. Example: 251-000-01H API Gravity Hydrometer
would be 251-004-01H Certified API Gravity Hydrometer.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
49
0-41-53_4a_GTE_Layout 1 10/24/12 11:01 AM Page 50
Density, Relative Density (Specific Gravity), or API Gravity
Constant Temperature Hydrometer Bath
Specifications
• Holds 12 hydrometer cylinders
• Can be used for Reid Vapor Pressure immersion type cylinders
• Conforms to ASTM D323, D1298, D6074, D6158 and related specifications
A versatile constant temperature bath designed for density/gravity
determinations of petroleum products at temperatures of up to 195°F (90°C),
and also for Reid Vapor Pressure determinations using immersion bombs.
Microprocessor PID control provides quick temperature stabilization without
overshoot and the unit is protected by an overtemperature control circuit that
interrupts power should bath temperature exceed a programmed cut-off point.
Dual LED displays provide actual and setpoint temperature values in °C/°F.
Communications software (RS232, etc.), ramp-to-set and other enhanced
features are available as extra cost options. Contact your Koehler representative
for information.
Capacity: twelve (12) hydrometer cylinders (without base)
or Reid Vapor Pressure one-opening type bombs
Temperature Range: ambient to 250°F (121°C)
Temperature Control Stability: ±0.2°F (±0.17°C)
Heater Range: 0-2500W
Bath Medium: 19 gal (71.9L) water
Electrical Requirements:
115V 60Hz, Single Phase, 22A
230V 50/60Hz, Single Phase, 11A
Ordering Information
\n
Catalog No.
K26400
K26490
Order Qty
Constant Temperature Hydrometer Bath, 115V 60Hz
1
Constant Temperature Hydrometer Bath, 230V 50/60Hz
K26410
Hydrometer Cylinder
Borosilicate glass, 151⁄2"lx2"dia. with 21⁄2" lip
ASTM 61F Thermometer
Range: 90 to 260°F
ASTM 61C Thermometer
Range: 32 to 127°C
Also available–Special bath to accommodate both ASTM D323 (Vapor
Pressure of Petroleum Products–Reid Method listed on page 93) and D942
(Oxidation Stability of Lubricating Greases by the Oxygen Bomb Method listed
on pages 152-153), as well as D525 (Oxidation Stability of Gasoline–Induction
Method listed on pages 81-82). Please contact a Koehler Customer Service
representative for additional information.
250-000-61F
Dimensions lxwxh,in.(cm)
Shipping Information
250-000-61C
30x14x28 (76x36x71)
Net Weight: 64 Lbs (29.0kg)
Shipping Weight: 118 lbs (53.5kg)
Dimensions: 11.4 Cu. ft.
Accessories
12
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Density, Relative Density (Specific Gravity), or API Gravity
Constant Temperature Hydrometer Bath
• Accommodates one standard 2"x15" (51x380mm)
hydrometer cylinder with base
• Compact design saves space
Thermostatically controlled water bath with 500W copper immersion heater
and hydraulic thermoregulator for operation at temperatures of up to 210 ±2°F
(99±1°C). Holds one 2"x15" (51x381mm) hydrometer jar — top of jar extends
11⁄2" (38mm) above the top of the bath for easy viewing of the hydrometer.
Insulated double-wall construction with stainless steel tank and shelf and
finished steel exterior. Has variable speed control for magnetic stirrer,
temperature control dial, and on/off switches for motor and power.
Specifications
Temperature Range: Ambient to 210°F (99°C)
Temperature Control Stability: ±2°F (±1°C)
Bath Medium: 2 gal (7.57L) water
Electrical Requirements:
115V 60Hz, Single Phase, 4.3A
230V 50/60Hz, Single Phase, 2.2A
Dimensions dia.xh.(cm)
Shipping Information
Bath Interior: 6x161⁄2 (15x42)
Overall: 9x22 (23x56)
Net Weight: 20 lbs (9.1kg)
Shipping Weight: 35 lbs (15.9kg)
Dimensions: 5 Cu. ft.
Ordering Information
Catalog No.
K26200
K26290
Constant Temperature Hydrometer Bath, 115V 60Hz
Constant Temperature Hydrometer Bath, 230V 50/60Hz
K26200 Hydrometer Bath
50
0-51_Layout 1 11/13/12 10:56 AM Page 1
Coulometric Karl Fischer Titrator
Specifications and Features
Test Method
Determines low concentrations of water in a wide range of liquid, gas and
powder samples. Used for assessing water content in petroleum and
petrochemical products including oils, gasolines, solvents, and fluids as
well as other products such as pharmaceuticals and cosmetics.
Coulometric Karl Fischer Titrator
• ASTM D 1533, D4928, D6304, IP 386, IP 438, API MPMS
Chap. 10.9, BS 60814, ISO 10101-3, ISO 10337, ISO 12937
• Simple operation
• Multi-language display and print out
• Integral high-speed thermal printer
• Small footprint
• Automatic Compensation of Errors
The AKF5000 offers new standards in versatility and ease of operation.
Providing fast, accurate and reproducible determinations of water content in
liquids, gases and powders. This easy to use titrator incorporates many stateof-the-art features. Designed to be equally suitable for meeting the routine
needs of the Quality Control laboratory or the more demanding and varied
requirements of research applications. Hard copies of results are provided by
the built in high-speed thermal printer, along with statistics, data input
parameters, sample ID numbers and time/date of analysis.
Ordering Information
Catalog No.
K90365
AKF5000 Compact Coulometric Karl Fischer Titrator,
115-240V 50/60Hz
Included Accessories
Glassware pack comprising twin port titration vessel, detector electrode,
generator electrode, dessicant tube, molecular seive, stirrer bar, injection
septa, funnel & 1ml glass syringe with luer needle.
Accessories
K90365-7
K90365-8
K90365-20
K90365-35
K90365-36
Gas Analysis Kit
(Comprised of gas inlet, gas outlet, seal ring & cap)
Carry Case
Formula Reagent Kit (Pack of 8 x 100ml anode reagent,
8 x 5ml cathode reagent)
Water Standard, 0.1 mg/ml, 5ml, pk/10
Water Standard, 1.0 mg/ml, 5ml, pk/10
51
Titration method: Coulometric Karl Fischer titration
End point detection: AC polarisation
End point indication: Visual display/print out/acoustic beep
Display: 40 character alphanumeric backlit LCD
Measuring range (possible): 1µg – 100mg water
Measuring range (typical): 1µg – 10mg water
Moisture range: 1 ppm – 100%
Max. sensitivity: 0.1 µg
Max. titration speed: 2.0 mg per minute
Max. current: 400 ma
Drift compensation: Automatically controlled
Start delay time: 0 - 30 minutes, user selectable
End delay time: 0 - 30 minutes, user selectable
Power supply: 90-264VAC, 47-63Hz Universal input
Precision: 10-100µg ±3µg, 100µg-1mg ±5µg,
above 1mg ±0.5%
Calculation modes: Weight/weight, user programmable
Weight/dilution ratio, user programmable
Volume/density, user programmable
Volume/volume, user programmable
Display format: µg, mg/kg, ppm, %
Print format: µg, mg/kg, ppm, %
Statistics: max, mean, min values upto 99 runs
Method storage: 10 user programmable methods
Sample ID number: user programmable
Printer: 42 character high-speed thermal printer
Stirrer speed: Microprocessor controlled
Dimensions: 250 x 245 x 120 mm
Weight: 3 kg
Language: English, Francais, Espanol, Portugues,
Deutsch and Magyar
Calendar/clock: Analysis time and date print out
0-41-53_4a_GTE_Layout 1 11/1/12 1:56 PM Page 52
Automatic Flocculation Titrimeter
Test Method
Samples of asphalt or heavy oil, or residuum are dissolved in toluene at
various concentrations and titrated with iso-octane or n-heptane at
controlled temperatures to determine the point of flocculation (asphaltene
precipitation) and calculate the Heithaus compatibility parameters. These
results are intended primarily as a laboratory diagnostic tool for estimating
the colloidal stability or compatibility of asphalt, asphalt cross blends, aged
asphalt, pyrolyzed asphalt, crudes, and heavy oil (residuum). The stability
values will allow the refiner to increase yields by allowing longer retention
time in process. The compatibility values will allow blending of crudes so
as to prevent asphaltene formation during blending and storage. Both of
these parameters are of utmost importance when we consider the price of
crude in today's market.
Automated Flocculation Titrimeter
•
•
•
•
Complete instrument and data acquisition system
Rapid, accurate and highly reproducible
Determines blending insolubility and solubility numbers
Generates the data to calculate the WRI Coking Index (patent pending) to
predict the proximity to coke formation during heavy oil distillation and
improve distillate yield
The Automated Flocculation Titrimeter (AFT) is a highly automated,
computerized instrument that acquires oil stability and compatibility
parameters directly. The AFT can be used to perform ASTM D6703 test
method for Automated Heithaus Titrimetry. The instrument operates as a
closed system with accurately controlled temperatures between 20-100°C,
important for properly determining Heithaus compatibility parameters. The
flocculation point is determined spectroscopically and the results are
analyzed by the data acquisition system, virtually eliminating operator error
in the interpretation of endpoints. A key benefit to the user is the fact that the
asphaltene concentration can be calculated by the software much faster that
tradition methods and with more accuracy. The utility of the original Heithaus
method has been expanded by developing multiple titration schemes. The
software uses the data from the expanded method to predict the proximity
to coke formation during heavy oil distillation. Many refiners stop distillation
short of coke formation to avoid fouling in distillation equipment, tanks and
transfer lines. The expanded AFT methodology allows the refiner to recover
additional distillate without the fear of fouling. This attribute of the instrument
should allow up to a 1-2% increase in yields if applied to a process.
Conversely, the added benefit of being able to predict coking tendency,
would prevent fouling of the process and thus decrease the use of energy in
production as well as reduce down time due to having to clean vessels after
fouling.
One of the primary uses of Heithaus values is to predict the compatibility
(P Index) of which oils and petroleum residua or asphalts can be mixed
together for shipping, processing, or in formulations without causing phase
separation. This is valuable to the refiner, researcher, or asphalt jobber who
supplies petroleum asphalts for highway and roofing applications because it
ensures that compatible asphalt blends are supplied. Incompatible asphalts
show early failure in both applications.
K47100 Automated Flocculation Titrimeter
Specifications
Conforms to the specifications of:
ASTM D6703
Temperature Range: 20 to 100°C
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Included Accessories
External Desktop PC with Data Acquisition Software
Fiber Optic Spectrometer with Multi-Bandpass Detector
High and Low Flow Rate Metering Pumps
Magnetic Stirring Plates
Programmable Circulator with External Probe to Monitor Jacket
Temperature of the Sample
Reaction Vessels
Quartz Flow Cell with Temperature Stability Feature
Glassware
Thermometer Probes
Digital Variable Sample Circulator with Built in Reverse
Shipping Information
Shipping Weight: 40 lbs (18.1kg)
Dimensions: 11 Cu. ft.
Dimensions lxwxh,in.(cm)
Base/Support Assembly: 12x24x36 (30.5x61x91.4)
Coking Index (US Patent 6,773,921)-Stability also influences coke
formation in the refining process. Another major use for the AFT is to acquire
the data needed to employ the Coking Index. The Coking Index is a
quantitative measure of the proximity to coking (fouling) during visbreaking,
distillation, transfer and storage of heavy oil. This allows the petroleum refiner
to optimize heavy oil processing and to recover the maximum amount of
distillate, and to stop the processing before fouling occurs.
Solubility Parameter-The solubility parameter at which asphaltenes begin
to precipitate and the solubility parameter of the whole oil can be calculated
from the AFT data.
52
Ordering Information
Catalog No.
K47100
K47190
Automated Flocculation Titrimeter, 115V 60Hz
Automated Flocculation Titrimeter, 230V 50/60Hz
In collaboration with Western Research Institute
0-41-53_4a_GTE_Layout 1 11/1/12 1:56 PM Page 53
Distillation of Petroleum Products at Reduced Pressure
Test Method
Determines the range of boiling points for petroleum products that can be
partially or completely vaporized at a maximum liquid temperature of
400°C at reduced pressures. The sample is distilled at a controlled, reduced
pressure under conditions that are designed to provide approximately one
theoretical plate fractionation. Initial and final boiling point is measured
and a distillation curve relating volume percent distilled and the
atmospheric equivalent boiling point temperature can be prepared.
VDS3000 Manual Vacuum Distillation System
• Conforms to ASTM D1160 and related specifications
• Comes standard with glassware set and accessories kit for
“Turn-Key” set up and operation
• Sturdy cabinet composed of aluminum frame and cold rolled
steel walls
• Control Unit can easily attach and detach from the main unit offering
versatility for laboratory workspace
• Clear protective door provides added safety while allowing the
operator full view of the system during testing
• Equipped with digital temperature and vacuum displays for improved
measurement reading and accuracy
• Upgrade to glassware set composed entirely of quartz available
upon request
K80300 VDS3000 Vacuum
Distillation System
The Koehler VDS3000 Manual Vacuum Distillation System is the latest
design for determining, at reduced pressures, the range of boiling
points for petroleum products according to ASTM D1160 and related
specifications. The main body of the system or cabinet is composed of
an aluminum frame and cold rolled steel walls. The base of the cabinet
houses a 5 Liter Stainless Steel Surge Tank to reduce pressure
fluctuations during testing. The control unit of the system features a
versatile, compact, modern design. Dual temperature displays
independently show both the overhead and flask temperature of the
system. Built in cooling fan rapidly cools the distilling flask allowing the
user to handle glassware and shorten turnaround time in between test
runs. Equipped with complete glassware set and accessories kit for
“Turn-Key” installation and operation of the Vacuum Distillation System.
Vacuum Pump and Refrigerated Constant Temperature Circulation Bath
are not included with the VDS3000 System but are available from Koehler
Instrument Company, Inc. Please refer to Recommended Accessories in
the Ordering Information Section for details. Side shelf for housing the
Vacuum Pump and Circulation bath is also available upon request.
Shipping Information
Shipping Weight: 120 lbs
Dimensions: 15 Cu.ft.
Dimensions wxdxh,in.(cm)
Cabinet: 291⁄2 x 91⁄4 x 321⁄2 (75 x 23.5 x 82.6)
Control Box: 73⁄4 x 91⁄4 x 93⁄4 (19.7 x 23.5 24.7)
Net Weight:
Cabinet: 62 lbs (28.2 kg)
Control Box: 21 lbs (9.6 kg)
The Standard Glassware Set consists of 500mL quartz distilling flask with
thermowell, vacuum jacketed distilling column and condenser assembly,
water jacketed receiving cylinder, 90° elbow adapter tube, Dewar-Type
Cold Trap with 10mL graduated receiver and stopcock drain, PT100 probe
adapter, PT100 vapor temperature probe and PT100 flask temperature
probe. The system also includes an adjustable scissor jack, heating
mantle, retaining springs, ball joint clamps, connection tubing, hose
clamps, quick connect adapters and fittings for easy connection of
jacketed glassware and tubing and vacuum grease.
Ordering Information
Catalog No.
K80300
VDS3000 Manual Vacuum Distillation System
115V 60Hz
K80390
VDS3000 Manual Vacuum Distillation System
220-240V 50/60Hz
Specifications
Order Qty
1
Accessories
Conforms to the specifications of:
ASTM D1160; ISO 6616; JIS K2254
Temperature Range: Ambient to 425°C (797°F)
Temperature Display: 0.1°C resolution
Temperature Accuracy: ±0.5°C
Vacuum Range: 0.1 Torr to Atmospheric Pressure (760 Torr)
Vacuum Display: 0.1 Torr resolution
Vacuum Accuracy: ± 0.2 Torr
External Circulator Temperature Range: Ambient +5°C to 150°C
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
K80320
K33062
K33063
53
VDS Vacuum Pump with Kit
1
Consists of Vacuum Pump, Hose Nozzle,
Centering O-Ring, Hinged Clamp, Outlet Filter,
Filter O-Ring, Filter Clamp, 1 Liter Vacuum Oil,
Connection Tubing, Hose Clamp (2)
Standard Constant Temperature Circulation Bath, 115V 60Hz
Standard Constant Temperature Circulation Bath,
220-240V 50/60Hz
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 54
Automatic and Semi-Automatic Vacuum Distillation of
Petroleum Products
Semi-Automatic Vacuum Distillation System
Test Method
Determines the range of boiling points for petroleum products that can
be partially or completely vaporized at a maximum liquid temperature
of 400°C at reduced pressures. The sample is distilled at a controlled,
reduced pressure under conditions that are designed to provide
approximately one theoretical plate fractionation. Initial and final
boiling point is measured and a distillation curve relating volume
percent distilled and the atmospheric equivalent boiling point
temperature can be prepared.
•
•
•
•
•
The Semi-Automatic Vacuum Distillation System features standard ASTM
D1160 glassware enhanced with microprocessor control. The vacuum level,
bath temperature and heating rates are programmable with up to 50 stored
programs. Vapor temperature, distilling flask temperature and vacuum level
are digitally displayed. Optional PC interface allows the distillation to be
controlled from a PC and for data to be stored on the PC.
Automatic Vacuum Distillation System
•
•
•
•
•
Fully Automatic Operation
Simple to Operate and Maintain
Vacuum Step Down Inhibits Foaming
Easy Access to all Components
Safety Shields & Doors Protect Operator
•
•
•
•
•
Automatic Vacuum Control
Automatic Heat Control
Vapor Temperature Display
Pot Temperature Display
Automatic shutdown for high pot or vapor temperature
Turn Key System
High Precision and Accuracy
Automatic Cleaning Cycle
Receiver is Easy to Remove
PC Control
Specifications
Conforms to the Specifications of:
ASTM D1160; ISO 6616
Distillation Temperature Range:
Ambient to 400°C (752°F)
Condenser Temperature Range:
Ambient +5°C to 150°C
Vacuum Range:
1.00 mmHg to 50 mmHg (0.13 to 6.7 kPa)
Electrical Requirements:
220-240V 50/60Hz
The Automatic Vacuum Distillation System is designed to make vacuum
distillation easy, safe and affordable. The self contained unit is controlled by a
standard PC. Fully automatic function minimizes the amount of operator time
needed for the test.
The latest Windows® operating system is included along with a state of the art
PC. The Windows®-based software is intuitive and guides you through the
distillation step by step. All data is saved to the hard drive in standard format
that can be easily opened by spread sheets or exported to LIMS. Files can be
accessed through portable USB drives, Ethernet connection or written to a
CD/DVD. A color printer is provided to print hard copies of the reports. Process
diagrams clearly show the current equipment status. Results can be viewed as
the distillation proceeds in both tables and graphs. Distillation parameters can
be modified at any time during the distillation.
Ordering Information
Catalog No.
K87170 Automatic Vacuum Distillation System, 220-240V 50/60Hz
K87180 Semi-Automatic Vacuum Distillation System, 220-240V 50/60Hz
Automatic and Semi-Automatic Vacuum Distillation of Crude Oil
Test Method
Semi-Automatic Crude Oil Vacuum Distillation System
ASTM D2892 covers the procedure for the distillation of stabilized
crude petroleum (see Note 1) to a final cut temperature of 400°C
Atmospheric Equivalent Temperature (AET). This test method employs
a fractionating column having an efficiency of 14 to 18 theoretical
plates operated at a reflux ratio of 5:1.
• Highly Automated - Minimizes operator time and makes test easier
to perform
• Complete System - Includes all equipment needed to perform a distillation
Fully Automatic Functions include Vacuum Control, Fraction Collector,
Condenser Bath Temperature, Heat Control of Column Heated Jacket, Shut
Down at End of Distillation, Reflux Ratio and AET Vapor Temperature
Calculation. Semi-Automatic Functions include Heat Control for Boiling Flask.
Manually Controlled Functions include Measurement of Receiver Volume and
Creation of Volume vs. Temperature Distillation Curve.
ASTM D5236 covers the procedure for the distillation of heavy
hydrocarbon mixtures having initial boiling points greater than 150°C
(300°F), such as heavy crude oils, petroleum distillates, residues, and
synthetic mixtures. It employs a potstill with a low pressure drop
entrainment separator operated under total takeoff conditions.
Distillation conditions and equipment performance criteria are
specified and typical apparatus is illustrated.
The Semi-Automatic Crude Oil Vacuum Distillation system can come in a
wide variety of configurations with single or multiple distillation columns.
Please contact your Koehler representative for required test method and
configuration.
Automatic Crude Oil Vacuum Distillation System
• Ergonomic Design makes the distillation system easy to use with easy
access to all components
• The Windows®-based software is intuitive and guides you through the
distillation process in a logical step-by-step fashion
The Automatic Crude Oil Vacuum Distillation System is a fully automatic crude
oil distillation system that complies with ASTM D2892 and D5236. The
distillation process is automated from beginning to end, minimizing the time
needed to operate the equipment. Its fully customizable modular design allows
for multiple configurations and easy switching from ASTM D2892 and D5236.
Please contact your Koehler representative for required method and
corresponding flask size and type.
54
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 55
Distillation of Petroleum Products
Test Method
The sample is evaporated and condensed under controlled conditions, and
observations are made of the temperatures at which various percentages
are recovered and/or the percentages recovered at specified temperatures.
Front View Distillation Apparatus
• Conforms to ASTM D86, E133 and related ASTM and international standards
• Choice of three different models
Front View Distillation Apparatus, Groups 1, 2 and 3–Meets all ASTM and
related specifications for distillation of motor and aviation gasolines, aviation
turbine fuels, naphthas, kerosenes, distillate fuels, natural gasoline, liquid
hydrocarbon mixtures and other petroleum products. Consists of fully
insulated stainless steel condenser and heater units. Heater unit includes flask
support platform, viewing window, 1250W heater with stepless variable
control, and rack and pinion heater elevation mechanism with push-turn
control knob. Please inquire about higher wattage heaters. White receiving
flask background facilitates viewing of fractions during test. Available with
right-hand or left-hand heater unit for convenient pairing. Includes graduate
support block and flask support boards.
Group 4 Front View Distillation Apparatus–Front View Distillation apparatus
designed for testing of Grade No. 2 fuel oil, Grade No. 2-D diesel fuel oil, gas
oils and other distillates requiring condenser bath temperatures of up to 140°F
(60°C). Also suitable for gasolines, aviation turbine fuels, naphthas, kerosenes
and other liquid petroleum products. Similar in features and construction to
the standard Front View Distillation Apparatus, but equipped with a 300W
copper immersion condenser heater with stepless electronic control. Available
with right or left-hand heater unit. Note: The Group 4 Apparatus can also run
distillations for petroleum products categorized as Groups 1, 2 and 3.
Specifications
Included Accessories
Conforms to the specifications of:
ASTM D86, D216, D233, D447,
D850, D1078, E133; IP 123, 195;
ISO 3405; DIN 51751; FTM 7911001, 791-1015; NF M 07-002
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Flask Support Boards A and C
Graduate Cylinder Support Block
K45090 Front View Distillation Apparatus
Ordering Information
Catalog No.
Front View Distillation Apparatus
K45000
Right-Hand Model, 115V 60Hz
K45100
Left-Hand Model, 115V 60Hz
K45090
Right-Hand Model, 220-240V 50/60Hz
K45190
Left-Hand Model, 220-240V 50/60Hz
Group 4 Front View Distillation Apparatus
K45200
Right-Hand Model, 115V 60Hz
K45300
Left-Hand Model, 115V 60Hz
K45290
Right-Hand Model, 220-240V 50/60Hz
K45390
Left-Hand Model, 220-240V 50/60Hz
Shipping Information
Shipping Weight: 65 lbs (29.5kg)
Dimensions: 13.3 Cu. ft.
Dimensions lxwxh,in.(cm)
151⁄4x181⁄4x191⁄2 (39x46x50)
Accessories
Accessories
ASTM Distillation Thermometers
Catalog No.
250-000-02C
250-000-07F
250-000-07C
250-000-08F
250-000-08C
250-000-37C
250-000-38C
250-000-39C
250-000-40C
250-000-41C
250-000-42C
250-000-102C
250-000-103C
250-000-104C
250-000-105C
250-000-106C
250-000-107C
Thermometer
ASTM 2C Partial Immersion
ASTM 7F Low Distillation
ASTM 7C Low Distillation
ASTM 8F High Distillation
ASTM 8C High Distillation
ASTM 37C Solvents Distillation
ASTM 38C Solvents Distillation
ASTM 39C Solvents Distillation
ASTM 40C Solvents Distillation
ASTM 41C Solvents Distillation
ASTM 42C Solvents Distillation
ASTM 102C Solvents Distillation
ASTM 103C Solvents Distillation
ASTM 104C Solvents Distillation
ASTM 105C Solvents Distillation
ASTM 106C Solvents Distillation
ASTM 107C Solvents Distillation
Catalog No.
Type
Capacity, mL
Flasks
332-003-006
A
100
332-003-001
B
125
332-003-002
C
200
332-003-005
D
250
Graduates
332-002-013
A
25
332-002-003
B
100
332-002-014
C
200
Flask Support Boards
K45410
A
11⁄4" (3.18)
K45420
B
11⁄2"(3.81)
K45430
C
2" (5.1)
K45440
D
23⁄4"(6.98)
Miscellaneous
K45540
Receiver Cooling Bath Jar
334-002-001 Top Silicone Plug, For Type A, B, & D Flasks pk/10
334-002-002
Side Silicone Plug
pk/10
334-002-003
Top Silicone Plug, For Type C Flask
pk/10
Range
–5 to +300°C
30 to 580°F
–2 to +300°C
30 to 760°F
–2 to +400°C
–2 to +52°C
24 to 78°C
48 to 102°C
72 to 126°C
98 to 152°C
95 to 255°C
123 to 177°C
148 to 202°C
173 to 227°C
198 to 252°C
223 to 277°C
248 to 302°C
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
55
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 56
Automatic Distillation of Petroleum Products
Test Method
The sample is evaporated and condensed under controlled conditions,
and observations are made of the temperatures at which various
percentages are recovered and/or the percentages recovered at
specific temperatures.
Automatic Distillation Analyzer 5000 Series
• Conforms to ASTM D86, D285, D4737 and related international
specifications
• Pt-100 RTD probe with automatic temperature calibration
system (°C or °F)
• Windows®-based software package for PC control with LIMS
export capabilities
• Automatic determination of initial boiling point (IBP), final boiling point
(FPB), dry point and barometric and residue corrections
• Diagnostic system continuously ensures proper unit performance
and user safety
• Automatic temperature and volume calibration
• Programmable distillation rate (2-15mL/min)
• Ready for distillation groups 1 - 4
• Networking for up to 32 units
• Powerful CFC-free cooling and heating system
• Receiver chamber heating system up to 60°C
• Precision level follower system with optical meniscus detector
• Integrated automatic fire extinguishing system with manual
operation override
K45603 Automatic Distillation Analyzer with Optional External PC
Specifications
Conforms to the specifications of:
ASTM D86, D285, D850, D1078, D4737; D189 Section 10; DIN 51751;
ISO 3405; IP 123; IP 195; JIS K2254l; NF M 07-002
Electrical Requirements:
120V 60Hz 20A
230V 50/60Hz 10A
Temperature
Distillation Range: 0 to 450°C (±0.1°C accuracy)
Condenser:
-5 to 60°C (±0.1°C accuracy); closed loop system
Receiver Chamber: 0 to 60°C (±0.1°C accuracy)
Distillation Parameters:
Distillation Rate:
2 to 15mL/min in 0.1mL increments, user
selectable
Receiver Volume:
0 to 100mL (±0.01mL accuracy) by photoelectric
infrared detection of meniscus by level following
system utilizing a precision stepper motor and a
special calibrated glass receiver; automatic
calibration of evaporated loss volume and
automatic volume calibration system ensures
highest accuracy
Barometic Pressure: Automatic barometric correction utility with automatic sensor, range 550 to 900 mm Hg (±1 mm
Hg accuracy)
Dry Point Detection: Automatic dry point detection board is included
with standard equipment and only requires a dry
point sensor, 200mL flask and PTFE plug for
ASTM D850 and D1078 tests.
Environment:
Operates at 0 to 25°C (113°F)
Dimensions lxwxh,in.(cm)
The Koehler Automatic Distillation Analyzer is designed to perform optimal
distillation analyses of gasolines, fuels, oils, solvents, aromatics, napthas,
kerosenes, hydrocarbons, and other volatile products to ensure conformity to
rigid quality control standards. The analyzer automatically performs tests,
processes results, and produces standard reports according to ASTM, ISO,
and related specifications.
Two Models are Available-The Automatic Distillation Analyzer 5000 Series
may be ordered for operation with an external PC (purchased separately) or
may be ordered with a built-in PC, internal touch screen monitor, virtual
keyboard and mouse. An easy-to-use Windows®-based PC communication
software expands user capabilities for data analysis and unit control.
Distillation methods and parameters can be easily created or modified.
Software calculates repeatability and reproducibility as per ASTM D86 as well
as standard and deviation against reference materials. Test results are
displayed in real-time and can include distillation curve and temperature with
or without barometric compensation and/or evaporation correction, distillation
rate, heating power curve, master curve comparison, and zoom function for
high resolution of heating and temperature curves. The heater compartment
is rapidly cooled at the completion of a distillation run to reduce operator
downtime. The analyzers are of rugged construction for instrument longevity
with a modular design for easy routine maintenance.
Receiver Chamber Heating System-The receiver chamber heating
system is ideal for samples that form waxes or other solids during distillation.
Shipping Information
21x21.5x27.75 (53.3x54.6x70.5) Shipping Weight: 260 lbs (95 kg)
Net Weight: 230 lbs (91kg)
Dimensions: 28 Cu. ft.
56
0-54-65_4b_GTEaa2_Layout 1 11/29/12 6:10 PM Page 57
Automatic Distillation of Petroleum Products
Dry Point Detection as Standard Feature- Dry point can be detected
visually or by automatic detection for ASTM D850 and D1078 test methods.
The unit is delivered ready with the PC board components already included as
standard to perform the dry point analysis. Simply order the Automatic Dry
Point Detection Kit for Solvents (see Ordering Information at right) which
includes dry point thermocouple, 200mL flask and PTFE plug to perform dry
point detection analysis automatically.
Ready for Groups 1 - 4 and more-Each Koehler Automatic Distillation
Analyzer 5000 Series comes ready with the equipment, accessories and
features as standard to properly run distillation groups 1 to 4 per ASTM D86
and related test specifications. No additional accessories are required. The
Windows®-based software package allows simple operator selection of the
programmed settings for each distillation protocol. No complicated routines
are needed to set up the unit. User defined programs are easily created for
customization of the analyzer.
Calculated Cetane Index-Calculated cetane index is a useful tool for
estimating ASTM D4737 cetane number where a test engine is not
available for determining this properly. It may be conveniently employed for
approximating cetane number where the quantity of sample is too small for an
engine rating. In cases where the cetane number of a fuel has been initially
established, the index is useful as a cetane number check on subsequent
samples of that fuel, provided its source and mode of manufacture remain
unchanged. The Cetane index is automatically calculated at the end of the test
if all the necessary variables are entered and is a component of the Windows®based software which comes standard with the unit.
K45703-TS Automatic Distillation Analyzer with
Touch Screen Display and Integrated PC
Ordering Information
Carbon Residue on 10% Distillation Residue-As per section 10, ASTM
Automatic Distillation Analyzer 5000 Series
Catalog No.
K45603
Automatic Distillation Analyzer, 120V 60Hz
K45604
Automatic Distillation Analyzer, 230V 50/60Hz
K45703-TS
Automatic Distillation Analyzer
with Touch Screen Display and Integrated PC,
120V 60Hz
K45704-TS
Automatic Distillation Analyzer
with Touch Screen Display and Integrated PC,
230V 50/60Hz
D189 the procedure for carbon residue of light distillate oils can be performed.
Included Accessories
Distillation Flask, 125mL with Markings
Ceran Plate, 25mm dia. hole
Ceran Plate, 38mm dia. hole
Ceran Plate, 50mm dia. hole
3 Point Calibrated PT100 Thermometer with Cable and Plug
Special Graduated Receiver Cylinder with Base
Wiper for Condenser Tube
Dropping Plate
Teflon Plug for 125mL Flask
Silicone Plug for Flask Side Arm
Dry Point Detection Board
Windows®-based Automatic Distillation Software
Accessories
K45634
K45635
K45655
K45656
K45657
K45656-A
K45650
K45651-E
K45651-B
K45601-03014
K45668
K45654-A
K45652-C
K45654
57
Distillation Flask, 125mL with Markings
PTFE Centering Stopper for 125mL Flask
Ceran Plate, 32mm dia. hole
Ceran Plate, 38mm dia. hole
Ceran Plate, 50mm dia. hole
Ceran Plate, 25mm dia. hole
PT100 Thermometer with Cable and Plug
Special Graduated Receiver Cylinder (with base)
Special Graduated Receiver Cylinder (without base)
Condenser Tube Cleaning Assembly
Dropping Plate
Flask 200mL with Silicon Plug
Silicone Plug
Automatic Dry Point Detection Kit
for D850 and D1078
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 58
Sulfur, Trace Sulfur, Volatile Chlorides
Sulfur in Liquefied Petroleum Gases
(Oxy-Hydrogen Burner)
Traces of Volatile Chlorides in
Butane-Butene Mixtures
Trace Quantities of Total Sulfur
(Wickbold Apparatus)
Sulfur in Petroleum Products
(Wickbold Apparatus)
Test Method
Determines total sulfur in liquefied petroleum (LP) gases and in liquid
petroleum products by the Wickbold oxy-hydrogen burner method. Also
suitable for burning butane-butene mixtures to determine trace amounts of
volatile chlorides.
Wickbold Combustion Apparatus
• Conforms to ASTM D2384, D2784 and related specifications
Burns samples in a stainless steel oxy-hydrogen burner to determine total
sulfur in petroleum products in the 0.1 to 300ppm range. Tests samples
which are viscous, highly aromatic or of high sulfur content with the use of
appropriate solvents.
K47590 Wickbold Combustion Apparatus
Combustion chamber and stainless steel burner are housed in an insulated
chamber with hinged heat-resistant and glare-proof shield for viewing burner
flame. To ignite flame, depress electronic spark ignitor handle at side of unit.
Ignitor shuts off when handle is released. Built-in pressure regulators with
gauges allow for accurate adjustment and monitoring of hydrogen, oxygen
and nitrogen pressure. Burner is easily disassembled for cleaning.
Specifications
Conforms to the specifications of:
ASTM D2384, D2747 (Withdrawn 1985), D2784,
D2785 (Withdrawn 1987); GPA 2140; IP 243;
ISO 4260; DIN EN 41; NF T 60-142
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Supplied with a complete set of Borosilicate Glass and quartz glassware,
including 200mL sample reservoir, sample capillary, combustion chamber,
absorber, spray trap and cooling bulb, and compression-type gas connection
fittings for 1⁄4" (6mm) O.D. tubing. Housed in a finished aluminum cabinet. For
LPG, natural gas and refinery gas samples, order accessory sample adapter.
Included Accessories
Complete Glassware Set
Sample Capillary
Sample Reservoir
Combustion Chamber
Absorber
Spray Trap
Cooling Bulb
Stainless Steel Burner
Ordering Information
Catalog No.
K47500
K47590
Wickbold Apparatus, 115V 60Hz
Wickbold Apparatus, 220-240V 50/60Hz
Order Qty
1
Accessories
K47580
Dimensions lxwxh,in.(cm)
Cabinet only: 15x13x181⁄2 (38x33x47)
Net Weight: 40 lbs (18.1kg)
Shipping Information
Shipping Weight: 62 lbs (28.1kg)
Dimensions: 11.9 Cu. ft.
K47510
K47520
K47530
K47540
K47550
K47560
K47570
58
Gas Sample Adapter
For burning liquefied petroleum, natural and
refinery gases in the Wickbold Apparatus.
Constructed entirely of stainless steel,
with 150mL sample cylinder, connecting tubing
and all necessary valves and couplings
Sample Capillary
Sample Reservoir
Combustion Chamber
Absorber
Spray Trap
Cooling Bulb
Stainless Steel Burner
1
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 59
Ramsbottom Carbon Residue of Petroleum Products
Test Method
Determines the ‘carbon residue’ left after evaporation and pyrolysis of
a sample oil in the Ramsbottom furnace, providing an indication of the
deposit forming tendencies of fuels and guidelines for the processing
of refinery products.
Ramsbottom Carbon Residue Apparatus
• Conforms to ASTM D524 and related specifications
• Microprocessor temperature control with digital display and
overtemperature cut-off
Thermostatically controlled coking furnace for five samples. Cast-iron block
type furnace reaches the standard test temperature of 550°C (1022°F) rapidly
and controls with ±1°C stability. Microprocessor temperature control has °C/°F
switchable digital setpoint and display. Operator and equipment are protected
by an overtemperature control circuit which automatically interrupts power to
the unit should block temperature exceed the programmed cut-off point.
Communications software (RS232, etc.), ramp-to-set and other enhanced
features are available as extra cost options. Contact your Koehler representative
for information. Heavily insulated stainless steel cabinet with three-layer
refractory top provides excellent heat retention.
Ordering Information
Catalog No.
K27100
K27190
K27100 Ramsbottom Carbon Residue Apparatus
Order Qty
Ramsbottom Carbon Residue Apparatus,
115V 60Hz
Ramsbottom Carbon Residue Apparatus,
220-240V 50/60Hz
1
Specifications
Conforms to the specifications of:
ASTM D524, D6074; IP 14; ISO 4262; FTM 791-5002; NF T 60-117
Furnace Type: Cast iron block
Capacity: 5 coking bulbs
Maximum Temperature: 650°C (1200°F)
Controller Sensitivity: ±1°C (± 2°F)
Heater: 0-2400W, ceramic band heater
Electrical Requirements:
115V 60Hz, Single Phase, 20.8A
220-240V 50/60Hz, Single Phase, 10.9A
Accessories
332-007-001
362-010-001
382-018-001
K27320
K27200
K29310
K29319
Coking Bulb
Borosilicate Glass, with capillary
Conforms to ASTM D524 specifications
Sample Charging Syringe
Needle, 18 gauge, 2"
Coking Bulb Filling Device
Convenient time saving device fills up to
five coking bulbs at a time. Ideal for viscous
fluids that are difficult to handle at room temperature.
Control Bulb
Stainless steel, with IC thermocouple.
May be used with a thermocouple pyrometer*
to verify compliance of the furnace
with ASTM performance requirements.
Digital Thermometer, 115V
Digital Thermometer, 220-240V
*The K29310 Digital Thermometer is suitable for
this purpose.
5
1
1
1
Dimensions lxwxh,in.(cm)
16x211⁄2x141⁄2 (41x55x37)
Net Weight: 64 lbs (29kg)
1
Shipping Information
Shipping Weight: 78 lbs (35kg)
Dimensions: 8.2 Cu. ft.
≥
Software compatible, inquire
with Koehler Customer Service.
59
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 60
Lead in Gasoline, Acidity, Salt Content
Lead in Gasoline by Volumetric Chromate Method
Acidity (Inorganic) of Petroleum Products by Color
Indicator Titration Method
Salt Content of Crude Petroleum and Products
Test Method
Determines lead, acid or salt content of crude petroleum and
products by extraction.
Dual Extraction Apparatus
• Conforms to ASTM D2547, IP 77, 182, 248 and ISO 2083 specifications
Consists of two sets of glassware mounted on a sturdy base/upright
assembly with separate line switches, rheostats and condenser water control
valves for each. Each glassware set includes 500mL boiling flask with heating
tube, Hopkins reflux condenser with aspirator, thistle tube, 250W heating coil
and 400mL Borosilicate Glass beaker.
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
ASTM D2547 (Withdrawn 1989);
IP 77, 182, 248; ISO 2083;
NF M 07-014, 07-023
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
17x11x361⁄2 (43x28x93)
Net Weight: 46Ibs (21kg)
Shipping Information
Shipping Weight: 66 lbs (30kg)
Ordering Information
K46600
Dual Extraction
Apparatus
Catalog No.
K46600
K46690
Dual Extraction Apparatus, 115V 60Hz
Dual Extraction Apparatus, 220-240V 50/60Hz
Order Qty
1
Conradson Carbon Residue of Petroleum Products
Test Method
Provides an indication of relative coke forming properties of petroleum oils.
The residue remaining after a specified period of evaporation and pyrolysis
is calculated as a percentage of the original sample.
Conradson Carbon Residue Apparatus
• Conforms to ASTM D189 specifications
A weighed quantity of sample is placed in a crucible and heated to a high
temperature for a fixed period. The crucible and the carbonaceous residue is
cooled in a desiccator and weighed. The residue remaining is calculated as a
percentage of the original sample and reported as conradson carbon residue.
Ordering Information
Catalog No.
K80030
Conradson Carbon Residue Apparatus
K80031
K80032
K80033
K80034
K80034-WT
K80035
K80036
K80039
Porcelain Crucible
Skidmore Crucible, with Iron Cover
Iron Crucible, with cover
Iron Hood, with bridge
Nickel-Chrome Triangle Wire Support
Refractory Block
Tripod
Burner
Order Qty
1
K80030
Conradson
Carbon Residue
Apparatus
Accessories
Specifications
Included Accessories
Conforms to the specifications of:
ASTM D189, D6074; ANS Z-11.25;
IP 13; ISO 6615; DIN 51551;
FTM 791-5001; NF T 60-116
Porcelain Crucible
Skidmore Crucible, with Iron Cover
Iron Crucible, with Cover
Iron Hood, with Bridge
Refractory Block
Nickel-Chrome Triangle Wire Support
Tripod
Burner
Shipping Information
Shipping Weight: 7 lbs (3.2kg)
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
60
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 61
Sediment in Crude Oils and Fuel Oils by the Extraction Method
Test Method
Determines sediment content of crude oil and fuel oils by extraction
with toluene.
Sediment Extraction Apparatus
• Conforms to ASTM D473 and related specifications
A test portion of the sample is placed in a refractory thimble. Toluene is gently
boiled and its vapors condensed and allowed to drip into the sample funnel.
The toluene washes out all of the crude oil or fuel oil leaving the insoluble
residue only in the thimble. The mass of the residue is calculated as a
percentage and is referred to as the sediment by extraction. Includes
condenser thimble basket, water cup and extraction thimble.
Ordering Information
Catalog No.
K48300
Sediment Extraction Apparatus
K42000
K42090
K48400
K48500
K48600
K48700
Powertrol Heater, 115V 60Hz
Powertrol Heater, 220-240V 50/60Hz
Condenser
Thimble Basket
Water Cup
Extraction Thimble
Order Qty
1
Accessories
1
K48300 Sediment Extraction Apparatus
Specifications
Conforms to the specifications of:
ASTM D473; IP 53; ISO 3735; DIN 51789; FTM 791-3002; NF M 07-010
Salts in Crude Analyzer
Test Method
Salt content is determined by measuring the conductivity of a solution
of crude oil in a polar solvent when subjected to an alternating electrical
current and is obtained by comparison of the resulting conductance to a
calibration curve of known salt mixtures.
Electrometric Salt Determinator
• Conforms to ASTM D3230 and IP 265 test specifications
• GOST certified
• Measures salt content, conductance, and temperature of crude oil
samples, and pH measurements of aqueous samples
• Measures Salts Concentration in the range of 0 to 150 PTB (lb/1000 bbl)
• Portable for field or laboratory testing with up to 8 hours of continuous
operation from internal Ni-Cd rechargeable batteries
• 18-bit analog-to-digital converter for high precision
• 24Kb RAM dedicated for data storage (about 500 test results)
• Data can be uploaded in a comma delimited format to a PC with
easy to use Windows® 2000/XP/Vista – based software via an RS232
serial data port
K23050
Salt in Crude Analyzer
Electrical Requirements
Shipping Information
115V 60Hz
220-240V 50/60Hz
Shipping Weight: 6 lbs (2.75kg)
Dimensions: 1.5 Cu. ft.
Dimensions lxwxh,in.(cm)
Determines the salt content, conductance, and temperature of crude oil
samples according to ASTM D3230 and IP 265 specifications. Utilizes the
latest low-voltage, synchronous detection technology for conductivity
measurements and a high-accuracy thermistor array to measure sample
temperature. Automatically calculates salt concentration directly from
acquired temperature and conductivity values. Measures conductivity over
four ranges 0-2, 2-20, 20-200, and 200-1500 mS with automatic range
selection. Self-calibration feature allows operator to adjust for any drift
without re-entering standard temperature curves. Complete data storage of
test results which is limited only by the hard drive capacity of external PC.
Easy-to-read alpha-numeric display shows any four of the following
parameters at one time as chosen by the operator: salts, conductance,
conductance @ 25°C, pH, pH millivolts, temperature (°C or °F), internal and
external battery voltages, date, time, logging ID, and ID increment value.
9x4.25x2.5 (23x10.8x6.5)
Net Weight: 2 lbs (1kg)
Ordering Information
Catalog No.
K23050
Salt in Crude Analyzer, 115/230V 50/60Hz
K23050-9
K23050-10
Mixed Salts Solution, 100ml
Mixed Salts Solution, 500ml
Accessories
61
0-54-65_4b_GTEaa4_Layout 1 12/4/12 4:39 PM Page 62
Water and Sediment Determination by Automatic Centrifuge
Test Method
Centrifugation provides a convenient means of determining sediment and
water content in crude oil, fuel oils, middle distillate fuels, and biodiesel.
Also used in determining the precipitation number, demulsibility
characteristics, trace sediments, and insolubles in used lubricating oils.
Automatic Heated Oil Test Centrifuge
• Choice of long, short, pear, or finger rotor assembly to accommodate
corresponding centrifuge tubes
• Accommodates four (4) centrifuge tubes of 6 or 8" conical ASTM types,
long, short, pear or finger tubes
• Automatic control of acceleration ramp, centrifugation speed,
and timing functions.
• 41⁄2" LCD Touch Screen Control Panel
• Substantial Insulation for Reduced Heat Loss
• Precise balancing, Quiet Operation
• Large, clear, top opening lid
• Class 1, Division 2 explosion resistant rating
K60002 Automatic Heated Oil Test Centrifuge
Ordering Information
Catalog No.
K60002
Automatic Heated Oil Test Centrifuge, 115V 60Hz
with Long Tube Rotor Assembly
K60092
Automatic Heated Oil Test Centrifuge, 230V 50/60Hz
with Long Tube (RA*)
K60002-ST Automatic Heated Oil Test Centrifuge, 115V 60Hz, Short Tube (RA*)
K60092-ST Automatic Heated Oil Test Centrifuge, 230V 50/60Hz
with Short Tube (RA*)
K60002-PT Automatic Heated Oil Test Centrifuge, 115V 60Hz , Pear Tube (RA*)
K60092-PT Automatic Heated Oil Test Centrifuge, 230V 50/60Hz
with Pear Tube (RA*)
K60002-FT Automatic Heated Oil Test Centrifuge, 115V 60Hz , Finger Tube (RA*)
K60092-FT Automatic Heated Oil Test Centrifuge, 230V 50/60Hz
*Rotor Assembly
with Finger Tube (RA*)
Fully automatic bench top centrifuge designed expressly for petroleum
testing applications. Features a 41⁄2" LCD touch screen control panel. This
integrated touch screen can be used to turn the heat on and off, set the
duration of the test, set the RCF/RPM values and choose the type of rotor
assembly and corresponding glassware to be used during the test. The motor
speed mechanism allows the user to simply set the desired speed and the
instrument will attain that speed. This mechanism calculates RPM based on
the given RCF and type of Rotor selected. The large, clear, top opening lid
provides for easy access to the rotor and tube holders and for cleaning of the
unit. The lid has a 181⁄2" diameter viewing window allowing the operator to view
inside the chamber for checking the status of the rotor and checking for
possible spillage of the centrifuge tubes. Molded PTFE cushions provide for
maximum protection and easy positioning of the tubes.
Safety Features
The Centrifuge comes equipped with a Safety Lockout Mechanism. Upon
emergency shutdown the door is locked and cannot be unlocked until the unit
comes to a complete stop, the unit is turned back on, and the stop/unlock key
is pressed on the touch screen display. Furthermore, the centrifuge cannot
start while the door of the chamber is open and the latch is not engaged. The
“Nitrogen Purge” feature allows for a slow release of Nitrogen into the bowl of
the centrifuge. This feature requires an external Nitrogen Gas source and can
easily connect to an Inlet port located at the back of the unit
Accessories
K60002-LT-1 Rotor Assembly for Long Tubes
K61101
Centrifuge Tube, Long, 100mL, 8", marked in mL
(ASTM D91, D96, D893, D1796, D4007)
K61106
Centrifuge Tube, Long, 100mL, 8", marked in 200 parts (ASTM D96)
K61110
Centrifuge Tube, Long, 100mL, 8", marked in mL every
1mL above 10mi (ASTM D96, D4007)
K61112
Centrifuge Tube, Long, 100mL, 8", marked in 200 parts
every 2 parts above 20 parts (ASTM D96)
K61109
Centrifuge Tube, Cone-Shaped, 100mL with capillary tip
capable of measuring 0.01 mL and readable by estimation to 0.005%
(ASTM D2273, D2709) (K61153 cushion required for each tube)
K61153
PTFE cushion for Long Tubes w/capillary tip (Req. for K61109 tubes)
K60002-ST-1 Rotor Assembly for Short Tubes
K61102
Centrifuge Tube, Short, 100mL, 6", marked in 200 parts
every 4 parts above 20mL (ASTM D96)
K61105
Centrifuge Tube, Short, 100mL, 6", marked in mL (ASTM D96)
K61107
Centrifuge Tube, Short, 100mL, 6", marked in mL every
2mL above 10mL (ASTM D96)
K61108
Centrifuge Tube, Short, 100mL, 6", marked in 200 parts (ASTM D96)
K60002-PT-1 Rotor Assembly for Pear Tubes
K61104
Centrifuge Tube, Pear, 100mL, marked in mL (ASTM D1966)
K61152
Centrifuge Tube, Pear, 100mL, with tube tip having graduations
of 0.01mL over the range 0 to 0.2mL (ASTM D2709)
K61111
Cork Stopper for Centrifuge Tubes
K60002-FT-1 Rotor Assembly for Finger Tubes
K61141
Centrifuge Tube, Finger Tube (API 2542)
Specifications
Conforms to the specifications of:
ASTM D91, D96, D893, D1796, D1966 , D2273, D2709, D2711, D4007,
D5546; IP 75, 145, 359; API MPMS Chapter 10.4, API 2542, 2548; ISO 3734;
DIN 51793; NF M 07-020
Capacity: Four (4) oil test centrifuge tubes: long (100mL), short (100mL),
pear (100mL), or finger tubes (12.5mL)
Maximum Speed: 2200 RPM
Maximum RCF: 1327 (long); 1170 (short); 865 (pear-shaped)
Timer: 0 to 999 min
Set Speed: 200 - 2200 RPM
Speed Readout: 0 - 2200 RPM
Temperature Control: ambient to 93°C (200°F)
Temperature Readout: Digital
Brake: Automatic Dynamic
Electrical Requirements
115V 60Hz, 10A
230V 50/60Hz, 5A
Dimensions lxwxh,in.(cm)
23x30x131⁄2 (51x76x34)
Net Weight: 93 lbs (42 kg)
Shipping Information
Shipping Weight: 110 lbs (50 kg)
Dimensions: 11.2 Cu. ft.
62
0-54-65_4b_GTEaa3_Layout 1 11/29/12 6:14 PM Page 63
Water and Sediment Determination in Crude Oil by Centrifuge
Test Method
For the determination of water and sediment of crude oil by centrifuge
method during field custody transfers. This test method is considered the
most practical method for field determination of sediment and water.
Portable Oil Test Centrifuge
• Two Models Available: Two (2) place 12VDC & Four (4) place 115/230VAC
• Accommodates either two 6” conical centrifuge short tubes or four short
cone / finger centrifuge tubes, model dependent
• Integrated Tube Holder / Pre-heater / Timer. Model Dependent
• Switchable Temperature Display between °C and °F
• Opening in Top Lid for Speed Calibration by Portable Laser Tachometer
K60094
Portable Heated Oil Test Centrifuge
Specifications
Conforms to the specifications of: ASTM D96; API MPMS Chapter 10.4, API 2542
Test Capacity: K60094: Two (2) short cone centrifuge tubes
K600X5/K600X6: Four (4) short cone or finger centrifuge tubes
Speed Range: 300 – 1800 RPM RCF Range: 20 - 700
Temperature Control: Ambient to 160°F (71.1°C)
Electrical Requirements: 12V DC 40, 115VAC 60HZ , 220-240VAC 50/60Hz
Ordering Information
Catalog No.
K61102
K61105
K61107
K61108
K61141
K61111
Accessories
Centrifuge Tube, Short, 100mL, 6”,
marked in 200 parts every 4 parts above 20mL
Centrifuge Tube, Short, 100mL, 6”, marked in mL
Centrifuge Tube, Short, 100mL, 6”,
marked in mL every 2mL above 10mL
Centrifuge Tube, Short, 100ml, 6”, marked in 200 parts
Centrifuge Tube, Finger Tube, 12.5mL
Cork Stopper
Ordering Information
Catalog No.
K60094
K60005
K60095
K60005-FT
K60095-FT
Portable Heated Oil Test Centrifuge, 12V DC 40A
Heated Oil Test Centrifuge, 4-Place, 115V 60Hz
Heated Oil Test Centrifuge, 4-Place, 220-240V 50/60Hz
Heated Oil Test Centrifuge, 4-Place, Finger Tube RA, 115V 60Hz
Heated Oil Test Centrifuge, 4-Place, Finger Tube RA,
220-240V 50/60Hz
K60005-FT8 Heated Oil Test Centrifuge, 8-Place, Finger Tube RA, 115V 60Hz
K60095-FT8 Heated Oil Test Centrifuge, 8-Place, Finger Tube RA,
220-240V 50/60Hz
K60006
Heated Oil Test Centrifuge, 4-Place, w/Timer, 115V 60Hz
K60096
Heated Oil Test Centrifuge, 4-Place, w/Timer, 220-240V 50/60Hz
K60006-FT Heated Oil Test Centrifuge, 4-Place, Finger Tube, w/Timer,
115V 60Hz
K60096-FT Heated Oil Test Centrifuge, 4-Place, Finger Tube, w/Timer,
220-240V 50/60Hz
Ash from Petroleum Products
Test Method
Determines the amount of ash in distillate and residual fuels, gas turbine
fuels, crude oils, lubricating oils, waxes, and other petroleum products.
Programmable Ashing Furnace
•
•
•
•
Six Complete Air Exchanges per Minute
Incoming air preheated for enhanced temperature uniformity
Digital PID Temperature Control
• Store up to 9 different programs
Integrated Timer
• Maximum Temperature of 1100°C
Specifications
Conforms to the Specifications of: ASTM D482, D874, D3174, D4422, D5184;
IP4, IP163, ISO 3987, ISO 6245; NF M 07-045; DIN 51352, DIN 51575
Temperature Range: Ambient - 1100°C Temperature Accuracy: ± 3°C
Oven Volume:
0.07 cu. ft. model: 3 L
0.16 cu. ft. model: 5 L
0.33 cu. ft. model: 9 L
0.47 cu. ft. model: 15 L
Power:
0.07 cu. ft. model: 1.2 kW
0.16 cu. ft. model: 2.4 kW
0.33 cu. ft. model: 3.0 kW
0.47 cu. ft. model: 3.6 kW
K24308
Programmable Ashing Furnace
Ordering Information
Electrical Requirements:
208V, 50/60Hz, Single Phase
Catalog No.
K24305 Programmable Ashing Furnace, 0.07 cu.ft. 208V 50/60Hz
K24306 Programmable Ashing Furnace, 0.16 cu.ft. 208V 50/60Hz
K24307 Programmable Ashing Furnace, 0.33 cu.ft. 208V 50/60Hz
K24308 Programmable Ashing Furnace, 0.47 cu.ft. 208V 50/60Hz
K24395 Programmable Ashing Furnace, 0.07 cu.ft. 240V 50/60Hz
K24396 Programmable Ashing Furnace, 0.16 cu.ft. 240V 50/60Hz
K24397 Programmable Ashing Furnace, 0.33 cu.ft. 240V 50/60Hz
K24398 Programmable Ashing Furnace, 0.47 cu.ft. 240V 50/60Hz
240V, 50/60Hz, Single Phase
Dimensions wxdxh,in.(cm) Net Weight: lbs (kg)
0.07 cu. ft. model: 14.96x14.57x29.53 (38x37x75) Net Weight: 44.1 (20)
0.16 cu. ft. model: 17.33x18.50x33.46 (44x47x85) Net Weight: 77.2 (35)
0.33 cu. ft. model: 18.90x21.66x35.44 (48x55x90) Net Weight: 99.3 (45)
0.47 cu. ft. model: 18.90x25.59x35.44 (48x65x90) Net Weight: 121.3 (55)
63
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 64
Automatic Density Meter
Test Method
Density is a fundamental physical property that can be used in conjunction
with other properties to characterize the quality of crude oils, light and
heavy fractions of petroleum and petroleum products. The test method
covers the determination of the density or relative density of crude oils,
petroleum distillates and viscous oils that can be handled in a normal
fashion as liquids at test temperatures between 15 and 35°C.
Specifications
Conforms to the specifications of:
ASTM D1250, D4052, D5002, D5931; DIN 51757
Measurement Ranges:
Density: 0 to 3 g/cm3
Temperature: 0°C to 90°C
Pressure: 0 to 10 bars
Measurement Modes: Continuous, Single, Multiple
Accuracy:
K86200: Density: 0.00005 g/cm3
Temperature: 0.03°C
K86201: Density: 0.0001 g/cm3
Temperature: 0.05°C
Repeatability:
K86200: Density: 0.00001 g/cm3
Temperature: 0.01°C
K86201: Density: 0.00005 g/cm3
Temperature: 0.02°C
Resolution: Density: 0.00001 g/cm3
Temperature: 0.01°C
Minimum Sample Volume: 1 ml, approximately
Wetted Materials: Borosilicate glass, Teflon (PTFE, ECTFE)
Display: 10.4 inch diagonal, 800-600 pixels, color, Flat Panel Monitor with
Resistant Touch Screen Interface, 200 bit brightness, gasketted for
spill protection.
Communication Interface:
K86200: Touch Screen User Interface
3 – USB Ports
2 – RS232 Ports
Ethernet Port for Network Connection
Keyboard, Bar Code Scanner,
Mouse, Network Capabilities
K86201: Touch Screen User Interface
3 – USB Ports
1 – Cat. 5 Port
2 – RS232 Ports
Keyboard, Bar Code Scanner,
Mouse, Network Capabilities
Video and Magnification: Video assisted view of cell, capable of
approximately 10X magnification
Internal Memory: 2 GB Non-removable Compact Flash
Electrical Requirements:
85 to 260 VAC; 48 to 62 Hz
150- 200 Watts
K86200 Automatic
Density Meter
Dimensions lxwxh,in.(cm)
91.44cm (L) x 48.26 cm (W) x 45.72 cm (H)
Shipping Information
Shipping Weight: 70 lbs. (31.75 kg)
Ordering Information
Catalog No.
K86200
K86201
Order Qty
1
1
Accessories
K86202
K86203
K86204
K86206
K86207
K86208
Included Accessories
Quick Start Guide
Desiccant
Filling Nozzles
NIST Standards
Automatic Density Meter, Model A
Automatic Density Meter, Model B
K86209
IQ/OQ/PQ Documentation
Luer Syringes
Connecting Fittings & Tubing
Manual
K86210
64
21 CFR Part 11 Option
Refractometer Control Module
Heated Interface Attachment
Bar Code Scanner - USB
Fluke Hart Thermometer Kit
Consists of Handheld Digital Thermometer,
Temperature Probe, and Calibration Certificate
Inkjet USB Printer Kit
Includes Inkjet Printer and USB communication cable
Laser USB Printer Kit
Includes Laser printer and USB communication cable
40 Column Serial Printer Kit
Includes 40 Column Serial (RS232) Printer,
Null Modern Cable, and Adapter
0-54-65_4b_GTE_Layout 1 10/24/12 11:03 AM Page 65
Rust Protection by Metal Preservatives in the Humidity Cabinet
Test Method
Tests the ability of metal preservatives to prevent steel panels from
rusting under conditions of high humidity. Polished steel panels are
immersed in the sample oil and then suspended in the humidity
cabinet for a specified test period.
Humidity Cabinet
• Conforms to ASTM D1748 and FTM 791-5310 specifications
Produces a moisture saturated atmosphere with continuous condensation
at a constant 120°F (48.9°C) for 33 steel test specimens. Test panels are
suspended on a 1⁄3rpm rotating stage. Air flow and water level control
systems maintain required conditions inside the cabinet per Mil. Spec. and
ASTM specifications. Air temperature is maintained at 120 ±2°F (48.9 ±1.1°C)
by a digital LCD electronic controller. A continuous heater circuit assists
the control heater in bringing the cabinet up to temperature prior to
testing. Overtemperature protection is provided by an adjustable digital
thermostat which cuts off power to the cabinet in case of overheating.
Cabinet interior is stainless steel lined and all interior components are of
stainless steel or chrome plated steel construction. Hinged cover consists of
two layers of desized cotton cloth mounted on a metal frame. Oil and
condensate dripping from the specimens are collected in a drip pan and piped
to an external drain.
Ordering Information
Catalog No.
Humidity Cabinet
K35200
Humidity Cabinet,
115V 60Hz
K35295
Humidity Cabinet,
220-240V 50Hz
K35296
Humidity Cabinet,
220-240V 60Hz
Order Qty
1
K35200 Humidity Cabinet
Specifications
Conforms to the specifications of:
ASTM D1748; FTM 791-5310
Capacity: 33 rust test specimens
Water Level Control: 8 in. (203mm)
Temperature Control Stability: ±2°F (± 1.1°C) (air temperature)
Heater Range: 0-1500W
Air Metering: 0.878±0.02832m3/h at standard temperature
and pressure (31±1 ft3/h)
Air Distribution: 20-diffuser manifold
Rotating Stage: 1⁄3rpm
Electrical Requirements:
115V 60Hz, Single Phase, 13.0A
220-240V 50Hz or 60Hz, Single Phase, 6.8A
Accessories
K35210
Steel Test Panels
Soft temper low carbon cold rolled steel,
surface ground on both faces
to a 10-20 micro-inch finish.
2x4x1⁄8"(51x102x3.2mm)
380-240-002 Aluminum Oxide Cloth, 240-grit
For test panel preparation.
Pack of 50
250-000-09F ASTM 9F Thermometer
Range: 20 to 230°F
250-000-09C ASTM 9C Thermometer
Range: –5 to +110°C
33
1
1
Included Accessories
Monel Test Specimen Hooks (33 sets)
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Dimensions lxwxh,in.(cm)
32x28x411⁄2 (81x71x105)
Net Weight: 206 lbs (93.4kg)
Digital Flowmeter option
is available for this unit.
Shipping Information
Shipping Weight: 279 lbs (126.6kg)
Dimensions: 41 Cu. ft.
65
0-66-78_4c_GTE_Layout 1 10/24/12 11:06 AM Page 66
Sampling of Petroleum and Petroleum Products and LP Gases
Sampling of Petroleum and Petroleum Products
Sampling Liquefied Petroleum (LP) Gases
Test Method Standards
All samplers conform to ASTM D4057 (formerly ASTM D270), D6074 or
ASTM D1265 specifications.
Sample Thief (Bacon Bomb)
•
•
•
•
•
Obtains bottom samples or samples from any level
Four different capacities
Plated brass, stainless steel or acrylic construction
Standard Viton O-ring seal
Optional metal-to-metal seal
Obtains samples from storage tanks, tank cars and drums. When the thief
strikes the bottom of the tank, a plunger assembly opens to admit the
sample. The plunger closes again when the bomb is withdrawn, forming a
tight seal. Samples can be taken at any depth with the use of a secondary
trip line, or extension rods may be added for obtaining samples at levels
of up to 18"(46cm) off the bottom. Equipped with plunger locking cam for
tight closure during transport (except for 4 oz 11⁄8" dia. model). Special
models include a 4 oz (118mL) ‘pencil’ model for sampling through small
diameter pipes and openings, and clear acrylic samplers with plated brass
plunger and end pieces. Modified samplers can be supplied for special
applications – we invite your inquiries.
K27790
K27760
Specifications and Ordering Information
Catalog
No.
K27700
K27701
K27790
K27795
K27791
K27792
K27780
K27785
K27781
K27782
K27770
K27771
K27772
K27760
K27761
K27762
Capacity
oz(mL)
32 (946)
32 (946)
16 (473)
16 (473)
16 (473)
16 (473)
8 (237)
8 (237)
8 (237)
8 (237)
4 (118)
4 (118)
4 (118)
4 (118)
4 (118)
4 (118)
Construction
plated brass
stainless steel
plated brass
plated brass
stainless steel
acrylic
plated brass
plated brass
stainless steel
acrylic
plated brass
stainless steel
plexiglass
plated brass
stainless steel
acrylic
Outside
Diameter
Seal
(O.D.)in.(cm.)
Viton O-ring
33⁄8 (8.6)
Viton O-ring
33⁄8 (8.6)
Viton O-ring
23⁄4 (7)
Metal Seat
23⁄4 (7)
Viton O-ring
23⁄4 (7)
Viton O-ring
23⁄4 (7)
Viton O-ring
25⁄16 (5.9)
Metal Seat
25⁄16 (5.9)
Viton O-ring
25⁄16 (5.9)
Viton O-ring
25⁄16 (5.9)
Viton O-ring
17⁄8 (4.7)
Viton-O-ring 17⁄8 (4.7)
Buna N O-ring 15⁄8 (4.01)
Viton O-ring
11⁄8 (2.8)
Viton O-ring
11⁄8 (2.8)
Viton O-ring
11⁄8 (2.8)
Overall
Length
in.(cm)
155⁄32 (38.5)
155⁄32 (38.5)
121⁄32 (30.6)
121⁄32 (30.6)
121⁄32 (30.6)
121⁄32 (30.6)
105⁄32 (25.8)
105⁄32 (25.8)
105⁄32 (25.8)
105⁄32 (25.8)
911⁄16 (24.6)
911⁄16 (24.6)
911⁄16 (24.6)
131⁄4 (33.7)
131⁄4 (33.7)
131⁄4 (33.7)
Shipping
Weight
lbs(kg)
13 (5.9)
13 (5.9)
9 (4.1)
9 (4.1)
8 (3.6)
8 (3.6)
5 (2.3)
5 (2.3)
5 (2.3)
5 (2.3)
4 (1.8)
4 (1.8)
3 (1.4)
3 (1.4)
3 (1.4)
3 (1.4)
Sample Thief Extension Rods
Installs in sample thief plunger assembly.
Stainless steel with threaded end.
Catalog
No.
K277-EXT1
K277-EXT2
K277-EXT3
K277-EXT6
K277-EXT12
K277-EXT18
K277C-EXT1
K277C-EXT2
K277C-EXT3
K277C-EXT6
K277C-EXT12
K277C-EXT18
Length
in. (cm)
1 (2.5)
2 (5.1)
3 (7.6)
6 (15.2)
12 (30.5)
18 (45.7)
1 (2.5)
2 (5.1)
3 (7.6)
6 (15.2)
12 (30.5)
18 (45.7)
Application
32,16 and
8 oz models
4 oz models
All-Levels Sample Thief
Adjustable-Level Sample Thief
Similar to the standard 16 oz (473mL) Sample Thief (Bacon Bomb), but
equipped with an adjustable needle valve opening instead of a plunger to
control rate of flow during ‘all-levels’ and ‘running’ sampling from storage
tanks. Plated brass construction.
Takes samples at depths up to 12" (30.5cm) from bottom. Similar to
the standard 16 oz (473mL) Sample Thief (Bacon Bomb), but with
built-in graduated extension rod adjustable between 0-12" (30.5cm).
Plated brass construction.
Ordering Information
Ordering Information
Catalog No.
K27800
All-Levels Sample Thief
Catalog No.
K27900
Adjustable Level Sample Thief
66
0-New CatalogPages_Layout 1 11/1/12 2:18 PM Page 2
Sampling of Petroleum and Petroleum Products and LPG
Drum Thief (Sampling Tube)
• Choice of plated brass or stainless steel construction
For tube sampling from barrels and drums. Takes bottom samples or all-levels
samples. 40" Long x 11⁄4" dia. (102x3.2cm). Maximum sample capacity of
24 oz (710mL). Shipping Weight: 6 lbs (2.7kg).
Ordering Information
Catalog No.
K27400
Drum Thief, plated brass
K27401
Drum Thief, stainless steel
Weighted Beaker
• Capacity 32 oz. (946mL)
• Choice of 3⁄4" or 11⁄2" (19 or 38mm) opening
For beaker sampling from tank cars, tank trucks, shore tanks, ship tanks and
barge tanks. Copper or stainless steel construction with weighted bottom.
Includes handle and chained cork. Takes all level samples, running samples,
and top, upper, middle, lower and outlet samples. Select 3⁄4" (19mm) opening for
light crude oils, light lubricating oils, kerosenes, gasolines, transparent gas oils,
diesel fuels, and distillates, or 11⁄2" (38mm) for heavy crude and fuel oils, heavy
lubricating oils and nontransparent gas oils. Shipping weight: 6 lbs (2.7kg).
Ordering Information
Catalog No.
K27600
K27610
K27601
Weighted Copper Beaker,
with 3⁄4" opening
Weighted Copper Beaker,
with 11⁄2" opening
Weighted Stainless Steel Beaker,
with 3⁄4" opening
K27400
Drum Thief
K27600
Weighted Beaker
LPG Sample Containers
• Two-valve type with 20% outage tube
• Built-in pressure relief valve
• Conforming to ASTM D1265 and GPA 2140 specifications
Welded stainless steel cylinders for obtaining representative samples of liquefied
petroleum (LP) gases. Two-valve type (1⁄4 IPS), with 20% outage tube and built-in
pressure relief valve factory preset between 540 to 600psi (38-42 kg/cm2).
Ordering Information
Catalog No.
K27851
K27852
K27853
K27854
K27856
LPG Sample Cylinder, 150mL
LPG Sample Cylinder, 300mL
LPG Sample Cylinder, 500mL
LPG Sample Cylinder, 1000mL
LPG Sample Cylinder, 3000mL
K27851 Series LPG Sample Cylinder
Specifications
Core-Type Sampling Thief (Tulsa Oil Thief)
• Obtains bottom samples or samples from any level
• Butterfly valve on bottom for easy sampling
• Stainless steel and brass construction
• Three Petcocks for draining at different levels
The K28100, Core-Type Sampling Thief is used to manually obtain samples of a
liquid, semi liquid or solid state whose vapor pressure at ambient conditions is
below 101kPa (crude oil, etc.)
Ordering Information
Conforms to the specifications of: ASTM D4057
Capacity: 33oz.
Empty Weight: 6.187 lbs.
Sample Container Material: Polycarbonate
Markings: Every inch from 3" to 14"
Distance from tank bottom to inlet valve: 1.729"
Max height: 21"
Max length: 4.7"
Max width: 4.2"
Catalog No.
K28100
Core-Type Sampling Thief
67
0-66-78_4c_GTE_Layout 1 10/24/12 11:06 AM Page 68
Freezing Point of Aqueous Engine Coolant Solution
Test Method
Determines the freezing point of aqueous engine coolant solutions by
cooling a sample with continuous agitation until a plateau is observed
in a time-temperature curve.
Freezing Point Apparatus
• Conforms to ASTM D1177 specifications
Determines freezing points of aqueous engine coolants. Includes 200mL
freezing tube with drilled cork, outer flask, motorized stirrer, clamps and
stand. Similar to K29700 Freezing Point Apparatus.
Electrical Requirements:
115V 60Hz
220-240V 50Hz
220-240V 60Hz
Ordering Information
Catalog No.
K29750
K29758
K29759
250-000-75F
250-000-76F
Order Qty
Freezing Point Apparatus, 115V 60Hz
1
Freezing Point Apparatus, 220-240V 50Hz
Freezing Point Apparatus, 220-240V 60Hz
ASTM 75F Thermometer Range: –35 to +35°F
1
ASTM 76F Thermometer Range: –65 to +5°F
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
K29750 Freezing Point Apparatus
Color of Maleic and Phthalic Anhydrides
Test Method
Molten samples of maleic or phthalic anhydride are compared with
Platinum-Cobalt color standards for determining sample purity and the
qualitative stability in the presence of contaminants. High color content
normally indicates contamination.
Anhydride Purity Bath
• Conforms to ASTM D3366 specifications
• Redundant overtemperature protection circuitry
• Microprocessor-based temperature controller
Electrically heated aluminum block features a microprocessor-based
temperature controller with overtemperature protection circuitry and a dual
LED temperature display. The heating unit provides temperature stability,
heating rates, and minimal temperature gradients which exceed ASTM
specifications, and is housed in an insulated steel cabinet with a chemicallyresistant painted finish. Up to six samples can be tested at a time using
Nessler tubes. Visual color comparisons are made against solutions of
Platinum-Cobalt color standards. (Please refer to pages 44-47 for Koehler’s
line of color measurement and comparison instrumentation.)
Ordering Information
K56300 Anhydride Purity Bath
Dimensions lxwxh,in.(cm)
Shipping Information
12x12x21 (31x31x54)
Net Weight: 65 lbs (30 kg)
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Shipping Weight: 76 lbs (35 kg)
Dimensions: 9 Cu. ft.
Catalog No.
K56300
Anhydride Purity Bath, 115V 60Hz
K56390
Anhydride Purity Bath, 220-240V 50/60Hz
K56306
Nessler Tubes
68
Order Qty
1
6
0-66-78_4c_GTEaa2_Layout 1 11/29/12 6:28 PM Page 69
Automatic Melting Point Range Apparatus
Automatic Melting Point Range Apparatus
Test Method
The melting point of a crystalline solid is the temperature at which the solid
to liquid phase transition occurs, referenced at one atmosphere (1 ATM)
of pressure.
• Conforms to BP Appendix 5 - Method 6 and GLP specifications
• Readily interchanged between automatic and manual detection of melting
point ranges
• Intelligent Lamp Intensity Control with Soft Start
• Storage capacity for up to 20 sample tests
• User-interactive software and data entry, including easy alphanumeric
entry of sample name, ID number, and date
• User selectable operating modes:
- AUTO detection mode: Start/end of melting point range is automatically
detected by a photosensing infrared device. The melting process is
recorded and viewed on-screen in real-time by a CCD camera.
- MANUAL detection mode: Start/end of melting point range can be
selected manually with a key-press by user. Sample melting point can
be determined as per BP method by ‘Heat & Cool’ temperature function.
As above, the melting process is recorded and viewed on-screen in
real-time by a CCD camera.
K90190 Automatic Melting Point Range Apparatus
The Automatic Melting Point Apparatus is the latest technology for
microprocessor-based determinations of melting point ranges of crystalline,
powdered and polymeric materials, and is used to assess sample purity.
Requires approximately 5mg of sample spread uniformly on a glass slide,
covered with a glass coverslip. The slide is placed on a uniformly heated, round
furnace and subjected to a heating profile as required by the user. Precise
temperature control gives reproducible results to within 1%. The unit contains
an automatic temperature safety cut-off feature if no melting points are
detected 15°C above the expected melting point or if the oven reaches 315°C.
The melting process is magnified, recorded, and viewed on-screen in real-time
by a CCD camera. The change in physical appearance of the sample with
respect to temperature is recorded, and the start/end of melting is observed
automatically. A representation of the entire process can be printed out in
graphical form for validation.
Dimensions lxwxh,in.(cm)
Shipping Information
Main Unit: 161⁄2x121⁄4x13 (42x31x33)
Monitor: 8x51⁄2x51⁄2 (20x14x14)
Net Weight: Main Unit: 22 lbs (10 kg)
Monitor: 1.8 lbs (0.8 kg)
Weight: 29 lbs (13 kg)
Dimensions: 3.6 Cu. ft.
Specifications
Conforms to the specifications of:
BP Appendix 5-Method 6; GLP
Visual Image: 10x magnified displayed on monitor
Temperature Range: ambient + 5 to 315°C
Heating Rates: 0.2, 0.5, 1.0, 2.0, 3.0, 6.0, 12.0°C/min
Temperature Readability: 0.1°C
Cooling Time: 20 minutes (300°C to ambient)
Temperature Accuracy: ±0.5°C (ambient + 5 to 200°C)
±0.8°C (200 to 315°C)
Sample size: 5 mg (approximately)
Sample Holder: Glass Slide ≤1mm ±0.02mm thick
Sample Cover: Glass Coverslip ±0.17mm thick
Temperature Sensor: Pt-100 (2 wire RTD)
Test Storage: Up to 20 tests with parameters
Electrical Requirements:
115V, 60Hz, Single Phase
220V, 50Hz, Single Phase
Ordering Information
Catalog No.
K90100
K90190
Order Qty
Automatic Melting Point Range Apparatus,
115V 60Hz
Automatic Melting Point Range Apparatus,
220V 50Hz
1
Accessories
K90100-1
K90100-2
K90100-3
Glass slides (pack of 500)
Cover slips (pack of 1000)
Sampling jig
69
0-66-78_4c_GTEaa2_Layout 1 11/29/12 6:28 PM Page 70
General Purpose Baths
Constant Temperature Water Baths
• Accurate Microprocessor Control
• Three User-defined Temperature Preset Buttons
• Redundant Safety Backup
• Front Panel Lockout
• Electronic Calibration
Economical constant temperature water baths offer superior temperature
control, range, and uniformity. Bath fluids can be controlled at temperatures
as high as 100°C (60°C without cover) with 0.1°C precision and +/- 0.2°C
uniformity. Bath temperature is displayed continuously on a bright, easy-toread LED panel in your choice of °C or °F. Set point temperature is recalled with
just the touch of a button. Three user-defined temperature preset buttons allow
for quick selection of often used temperature set points.
Dual thermostats provide optimum protection for your work and water bath.
The high limit alarm alerts you if bath temperature exceeds your pre-set limit.
A secondary Safety Set thermostat guards against thermal runaway,
automatically disconnecting heater power should bath temperature get too
high or the liquid level drop too low.
The Constant Temperature Water Baths are also designed for operating
convenience. The steeply gabled, polycarbonate cover accommodates
glassware of varying heights and tilts out of your way when loading or
removing samples, allowing condensate to drain neatly back into the bath.
K33056 General Purpose Water Bath, 10L
Specifications
Temperature Control: 0.1°C setpoint and °C/°F switchable LED display
Temperature Stability: +/- 0.2°C
Temperature Range: Ambient to 100°C with cover,
Ambient to 60°C without cover
Ordering Information
Catalog No.
Capacity
Electrical Requirements
Overall Dimensions
LxWxH
Opening Dimensions
LxWxH
Shipping Weight
K33050
K33051
2L (0.5 gal)
120V, 50/60Hz, 2.5A
240V, 50/60Hz, 1.25A
8.94x7.90x8.13 in
22.71x20.07x20.65 cm
5.31x5.88x5.81 in
13.49x14.94x14.76 cm
11 lbs
4.99 kg
K33052
K33053
2L shallow
(0.5 gal)
120V, 50/60Hz, 2.5A
240V, 50/60Hz, 1.25A
9.44x13.65x8.13 in
23.98x34.67x20.65 cm
5.81x11.69x2.50 in
14.76x29.69x6.35 cm
12 lbs
5.44 kg
K33054
K33055
5L (1.3 gal)
120V, 50/60Hz, 4.2A
240V, 50/60Hz, 2.1A
9.44x13.65x8.13 in
23.98x34.67x20.65 cm
5.94x11.75x5.94 in
15.09x29.85x15.09 cm
15 lbs
6.80 kg
K33056
K33057
10L (2.6 gal)
120V, 50/60Hz, 4.2A
240V, 50/60Hz, 2.1A
15.43x14.90x8.13 in
39.19x37.85x20.65 cm
11.69x12.75x5.94 in
29.69x32.39x15.09 cm
23 lbs
10.43 kg
K33058
K33059
20L (5.2 gal)
120V, 50/60Hz, 8.3A
240V, 50/60Hz, 4.15A
15.19x21.65x8.13 in
38.58x54.99x20.65 cm
11.50x19.50x5.88 in
29.21x49.53x14.94 cm
30 lbs
13.61 kg
K33060
K33061
28L (7.3 gal)
120V, 50/60Hz, 8.3A
240V, 50/60Hz, 4.15A
15.19x21.65x10.13 in
38.58x54.99x25.73 cm
11.63x19.56x7.94 in
29.54x49.68x20.17
33 lbs
14.97 kg
70
0-66-78_4c_GTEaa2_Layout 1 11/29/12 6:28 PM Page 71
General Purpose Baths
Programmable Model - Constant temperature circulating bath provides precise
temperature control stability of ±0.01°C and features time/temperature
programming, remote probe capability, and a variable speed pressure/suction
(duplex) pump. An RS232 interface and PC programming software are
standard while LabView™ drivers and Excel® macros provide even greater
programming and data logging conveinience. A full graphic LCD display and
multi-language help menus simplify operation and set-up.
Standard Model - Economical constant temperature circulating bath model.
Microprocessor temperature control ranges from 5°C to 150°C with ±0.05°C
stability. This model features a bright set-and-read LED display with a readout
accuracy of ±0.5°C, three user-defined set point buttons, and a 2-speed
pressure (simplex) pump suitable for closed loop applications.
K33064 Constant Temperature
Circulating Bath
Constant Temperature Circulating Baths
• Above Ambient Temperature Control
• Available in Three Different Capacities: 6, 13, and 28 Liter
• Large Reservoir Opening
• Microprocessor temperature control with °C/°F digital temperature set
and display
• Adjustable Over-Temperature protection and Low-Liquid Cutoff
Specifications
Temperature Range:
K33064, K33065: +5°C to 200°C
All Other Models: +5°C to 150°C
Temperature Stability:
Programmable Model: ±0.01°C
Standard Model: ±0.05°C
Readout Accuracy:
Programmable Model: ±0.25°C
Standard Model: ±0.5°C
Temperature Readout: °C or °F
Pressure Flow Rate:
Programmable Model: 30 lpm max. (60 Hz)
22 lpm max. (50 Hz)
Standard Model: 2-speed, 9 or 15 lpm
Suction Flow Rate:
Programmable Model: 22 lpm max. (60 Hz)
15 lpm max. (50 Hz)
Standard Model: N/A
Heater:
Programmable Model: 1100 Watts (60 Hz)
2200 Watts (50 Hz)
Standard Model: 1100 Watts (60 Hz)
1600 Watts (50 Hz)
Ordering Information
Catalog No.
Model
Capacity
K33062
K33063
Standard
6L (1.6 gal)
K33064
K33065
Programmable
K33066
K33067
Electrical Requirements
Overall Dimensions
LxWxH
Working Access
LxWxD
Shipping Weight
120V, 50/60Hz
240V, 50/60Hz
14.25x8.25x8.14 in
37.5x21x35.6 cm
5.25x5.25x5.5 in
13.3x13.3x14 cm
24 lbs
11 kg
6L (1.6 gal)
120V, 50/60Hz
240V, 50/60Hz
14.25x8.25x8.14 in
37.5x21x35.6 cm
5.25x5.25x5.5 in
13.3x13.3x14 cm
30 lbs
14 kg
Standard
13L (3.4 gal)
120V, 50/60Hz
240V, 50/60Hz
15.5x10.88x14.75 in
39.4x27.6x37.5 cm
5.25x8.5x7.75 in
13.3x21.6x19.7 cm
31 lbs
14 kg
K33068
K33069
Programmable
13L (3.4 gal)
120V, 50/60Hz
240V, 50/60Hz
15.5x10.88x14.75 in
39.4x27.6x37.5 cm
5.25x8.5x7.75 in
13.3x21.6x19.7 cm
40 lbs
18 kg
K33070
K33071
Standard
28L (7.3 gal)
120V, 50/60Hz
240V, 50/60Hz
22.75x13.19x14.75 in
55.8x33.5x37.5 cm
12.13x10.38x8 in
30.8x26.4x120.3 cm
42 lbs
19 kg
K33072
K33073
Programmable
28L (7.3 gal)
120V, 50/60Hz
240V, 50/60Hz
22.75x13.19x14.75 in
55.8x33.5x37.5 cm
12.13x10.38x8 in
30.8x26.4x120.3 cm
50 lbs
23 kg
71
0-66-78_4c_GTE_Layout 1 10/24/12 11:06 AM Page 72
Water in Petroleum Products & Bituminous Materials
by Distillation
Test Method
Determines the water content in petroleum products, tars, emulsified
asphalts and other bituminous materials by the distillation method.
Distillation Apparatus
• Conforms to ASTM D95, E123, D244 and related specifications
Consists of still, ring burner, glassware and all mounting hardware.
Specifications
Conforms to the specifications of:
ASTM D95, E123, D244, D370*; AASHTO T55, T59; API MPMS Ch. 10.5;
IP 74, 291; FTM 791-3001; ISO 3733; NF T 60-113
*requires different glassware–information is available upon request.
Shipping Information
K31800: Shipping Weight: 10 lbs (4.5kg)
Dimensions: 1.3 Cu. ft.
K31810/K31820: Shipping Weight: 18 lbs (8.2kg)
Dimensions: 2.8 Cu. ft.
Ordering Information
K31800 Metal Still
Dean & Stark Moisture Test Apparatus
Catalog No.
K31800
• Conforms to ASTM D95 and related specifications
Consists of 400mm condenser, 10mL receiver, 1000mL flask and
mounting equipment.
K31910
K31810
Ordering Information
Catalog No.
K31830
K31820
Dean & Stark Apparatus
Metal Still
Plated brass and copper, with lid and
clamp assembly, gasket and O-ring seal.
Ring Burner, 5" (12.7cm) dia.
Glassware Set
Includes 400mL condenser, 10mL and 25mL
receiving traps
Mounting Equipment
Consists of stand and connecting hardware
General Purpose Heater
Utility Heater
•
•
•
•
For general laboratory applications
Precise, reproducible settings
1000W or 1250W nichrome heater option
Accepts flat bottom and round bottom beakers and flasks
Variable control electric heater designed for efficient, reproducible heating of
flat bottom and round bottom beakers and flasks. Electronic unit control with
reference dial permits fine temperature adjustment and accurate repeatable
settings. Includes porcelain refractory heater with nichrome element (1000W
or 1250W) and refractory support plate that reverses to accept different size
beakers and flasks. Polished stainless steel housing has cooling vents and two
dovetail clamps to accommodate accessory support rod. Line switch and 6ft.
(1.8m) three-conductor line cord and plug are included.
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Dimensions lxwxh,in.(cm)
Shipping Information
5x5x10 (12.7x12.7x25.4)
Shipping Weight: 8 lbs (3.6 kg)
Net Weight: 41⁄2 lbs (2.0kg)
Dimensions: 1.5 Cu. ft.
Ordering Information
Catalog No.
K42000
K42001
K42090
K42091
Utility Heater, 115V 60Hz, 1000W
Utility Heater, 115V 60Hz, 1250W
Utility Heater, 230V 50/60Hz, 1000W
Utility Heater, 230V 50/60Hz, 1250W
K42000 General Purpose Utility Heater
72
Order Qty
1
1
1
0-66-78_4c_GTE_Layout 1 10/24/12 11:06 AM Page 73
Refractive Index of Petroleum Products
Test Method
Refractive index is a fundamental physical property that is used in
conjunction with other properties to characterize pure hydrocarbons
and their mixtures. It is a useful property for concentration
measurements, purity determinations and chemical identification.
Automatic Petroleum Refractometer
• Conforms to ASTM D1218, D1747 and D5006 test specifications
• Electronic heating and cooling Peltier system eliminates the need for a
circulating water bath
• Automated and precise refractive index measurements
• Rugged sapphire prism
• Designed for samples ranging from clear to highly colored, dark and opaque
• Clear graphical LCD display with on-screen instructions and
full menu operation
• Multipoint calibration routines maximize accuracy
• RS232C and centronics communication ports
The Koehler Automatic Refractometer uses precision optics and superior
image analysis to extend the repeatability and accuracy of refractive index
measurements for petroleum products. Subjectivity is removed from tests
results because no manual activities such as aligning shadowlines or
reading analog scales are necessary. Opaque hydrocarbons present no
problem for this unit which uses reflected light measurement technology as
opposed to manual refractometers which are of the transmission type. The
dual temperature control system and flat, easy clean sample area make the
instrument ideal for viscous or sticky samples.
K27550 Automatic Refractometer
Specifications
Measurement Scales:
Refractive Index (RI)
BRIX (% sucrose)
Temperature Corrected RI
Temperature Corrected BRIX
Ten User-Programmable Scales
Illumination: 589nm light emitting diode with interference filter
(estimated life: 100,000 hrs)
Range:
Dissolved Solids: 0 to 95% solids
Refractive Index: 1.29000 to 1.70000nD
(nD - Sodium D-Line Refractive Index)
Readability:
Standard Mode: 0.1% Solids 0.0001nD
Extended Mode: 0.01% Solids 0.00001nD
Precision:
Standard Mode: ±0.02% Solids ± 0.00002nD
Extended Display Mode: Refractive Index Standard Oils ± 0.00002
Typical clear aqueous samples, % Solids Temperature Compensated,
as sucrose ±0.02%
Calibration Fluid: refractive index standard oil, NIST traceable
nominal value 1.495 RI, 67.61 BRIX
Sample Types: Transparent, translucent or opaque
Prism Assembly: Stainless steel, synthetic sapphire sealed with
solvent-resistant epoxy
Calibration:
1 point - Water only
2 point - Water and refractive index or Brix standard
Electrical Requirements:
110-240V 50/60Hz
Two models are available. Models K27550 and K27560 conform to ASTM
D1218 and D1747 (maximum temperature 100ºC) and measures to the fifth
decimal place refractive index or one hundredth place in percent solids.
The K27550 also has a built in data storage system with secure electronic
signature recording.
The refractometer incorporates numerous innovations designed to improve
the accuracy of petroleum product testing. A 589 nanometer filter gives true
Sodium D-Line refractive index readings. The large graphical LCD is easy to
read and provides complete sample analysis documentation including the
reading, temperature and scale name of the screen.
Set-up, diagnostic and calibration routines are displayed with easy to follow
step-by-step instructions. User-developed customer calibration curves may be
programmed allowing automatic temperature correction and direct percent
concentration, percent reaction completion, etc. This unit has been used
successfully throughout the petrochemical industry.
Ordering Information
Catalog No.
K27550
Automatic Petroleum Refractometer for D1218 and D1747
110-240V 50/60Hz
Includes data storage
K27560
Automatic Petroleum Refractometer for D1218 and D1747
110-240V 50/60Hz
Dimensions lxwxh,in.(cm)
Accessories
K27504
K27505
151⁄2x10x41⁄2 (391⁄2x251⁄2x111⁄2)
Net Weight: 23 lbs (101⁄2kg)
Calibration Fluid,
Certificate of NIST traceability included.
Refractometer Communication Software Package,
with real-time data export into Microsoft® Excel.
Shipping Information
Shipping Weight: 30 lbs (14kg)
Dimensions: 5 Cu. ft.
73
0-66-78_4c_GTE_Layout 1 10/24/12 11:06 AM Page 74
Calibration of Liquid-in-Glass Thermometers
Specifications
Thermometer Calibration Bath
Temperature Range: –30°C to +200°C
For sub-ambient temperatures, refrigerated recirculating coolant
is required from an external source.
Temperature Uniformity: ±0.02°C
Temperature Limit Control: –16.7°C (30°F) above setpoint and
204°C (400°F) maximum
Heater Range: 0-750W
Circulator: 1⁄20 hp impeller
Working Depth: Oil Bath: 12" (30.5cm)
Ice Bath: 101⁄2" (26.7cm)
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
• Calibrates thermometers, temperature controllers and other temperature
instruments against a factory certified thermometer traceable to
NIST standards
• Verifies accuracy of routine thermometers
• For temperatures between ambient to 200°C (–30°C with the use of
circulated refrigerated coolant)
• Digital temperature control with temperature uniformity of ±0.02°C
• Built-in ice bath for performing ice point calibrations
• Meets the requirements of NBS Monograph 150
Constant temperature calibration bath for liquid-in-glass thermometers,
dial thermometers, digital thermometers and other temperature
measuring instruments. Consists of an oil bath with digital electronic
control providing temperature uniformity of ±0.02°C in the range –30°C
to +200°C. Accessory Standard Thermometer is calibrated and certified
traceable to NIST standards. Turntable rack inserts in bath to immerse six
thermometers or temperature probes and the standard thermometer.
Bath depth of 12" (30.5cm) accommodates all partial immersion
thermometers and most 15" total immersion thermometers.
Ordering Information
Catalog No.
K26500
K26590
Features digital setpoint and display (°C/°F switchable) of bath temperature
for maximum convenience, and overtemperature control to prevent
accidental overheating. Built-in cooling coil permits circulation of tap
water or refrigerated coolant to permit operation at sub-ambient
temperatures or to facilitate rapid cool down for multi-point calibrations.
Equipped with drains for oil bath and ice bath.
Dimensions: lxwxh,in.(cm)
Shipping Information
28x24x21(71x61x53)
Net Weight: 523⁄4 lbs (23.9kg)
Shipping Weight: 66 lbs (30kg)
Dimensions: 8.2 Cu. ft.
Order Qty
Thermometer Calibration Bath,
115V 60Hz
Thermometer Calibration Bath,
220-240V 50/60Hz
1
Accessories
K26501
K26503
K26502
Standard Thermometer,
certified traceable to NIST Standards
at 0, 20, 37, 56, 80, 100, 121, 140,
160, 180 and 200°C
Thermometer Magnifier(10X)
Thermometer Carrying Case,
holds K26501 Standard Thermometer
pH / Conductivity Meters
pH Meter
Specifications
This bench-top pH meter is an ideal help in every laboratory for routine or R&D
level measurement. This instrument measures pH, mV and has 40- point data
memory storage. Instrument has two operating modes 1. Standard mode
2. GLP mode: 40 data readings can be stored, printed and scanned on display.
For GLP mode, additional entries of sample name and ID number can be
stored.
Temperature Range: 0 to 150°C
Temperature Resolution: 0.1°C
Temperature Accuracy: ± 0.2°C
Display: 20 x 2 line back-lit LCD
Keyboard: Aphanumeric splash water-proof polyester soft keys
Output: 1 – Parallel Port for Printer, 1 – RS232C for PC
Environmental Operating Temperature: Ambient to 45°C
Relative Humidity: 5 to 90% non-condensing
Electrical Requirements:
115V 60Hz
230V 50Hz
The optional Data logging function enables the user to store 24 data points
consisting of pH, temperature and time readings. For example, as required in
kinetic study or in any chemical reaction. Time intervals from 1min. to 1Hr. in
steps of 1min. are available. User entries of pH limit values make the data more
defined and informative.
Dimensions wxdxh,in.(cm)
12x8.7x27.6 (30.5x22x70)
Net Weight: 4.85 lbs (2.2kg)
Conductivity Meter
Koehler offers the perfect choice of a bench top conductivity meter for
measurements in the laboratory - whether routine or at the R & D level. The
conductivity meter offers better operating comfort and measuring confidence
in all areas of application. Due to a user selective temperature function, the
instrument calculates the conductivity at the reference temperature 25 ± 0.1°C
with a linear function.
Ordering Information
Catalog No.
K90601
K90691
K90602
K90692
K90603
K90693
Conductivity is an important factor in water analysis for quality of drinking
water, direct ionic concentration measurement in pharmaceutical preparations,
waste water treatment plants, pollution control in lakes & rivers, boiler feed
water and oceanography to determine salinity and TDS.
74
pH Meter, 115V 60Hz
pH Meter, 230V 50Hz
Conductivity Meter, 115V 60Hz
Conductivity Meter, 230V 50Hz
pH / Conductivity Meter, 115V 60Hz
pH / Conductivity Meter, 230V 50Hz
1
1
1
0-66-78_4c_GTEaa2_Layout 1 11/29/12 6:28 PM Page 75
Automatic Titration
Test Method
For determination of Total Acid Number (TAN), Total Base Number (TBN),
Mercaptan Sulfur and Karl Fischer Water Content of petroleum products,
lubricants and transformer insulating oils. Titration is the fundamental
chemical analysis procedure whereby the concentration of a chemical
substance in solution is determined by reacting it with a measured amount
of another chemical. The Auto titrator performs this analysis using a motor
driven dispenser, stirred reaction vessel and electrodes which sense the
completion of reaction by measuring the potential difference between two
electrodes. Automatic Titration increases accuracy, repeatability and
reproducibility as well as minimizing errors in calculation and
documentation.
Automatic Titrator
The Automatic Titrator is capable of performing a wide range of Titrations:
• Acid-base or aqueous titration
• Redox titration
• Complexometric titration or EDTA titration
• Blank titration
• Silver Assay titrations
• Non-aqueous titration
• Argentometric or Precipitation titration
• Voltametric / KF Titration
• Back titration
K90500 Automatic Potentiometric Titrator
Specifications
The Automatic Titrator is provided with two-point auto calibration and
standardization (zero offset). The instrument is capable of displaying pH and
mV of the sample, with temperature compensation. The Automatic Titrator can
accept a variety of electrodes to cater to various applications in different fields.
The liquid path is comprised of Teflon tubing, a Teflon lined valve and gas tight
burette with a Teflon plunger head. It creates a chemically inert system for any
sensitive analysis. The instrument is supplied with high speed vortex stirrer
with digital speed indication. This specially designed stirrer provides excellent
homogenous mixing of samples. An optional magnetic stirrer is also available.
Ordering Information
Catalog No.
K90500
K90590
Automatic Potentiometric Titrator, 115V, 60Hz
Automatic Potentiometric Titrator, 230V, 50Hz
K90500-1
K90500-2
K90500-3
K90500-4
K90500-5
K90500-6
Karl Fischer Titrator Burette Assembly
Filter Desiccant Dryer Tube
Magnetic Stirrer with Holding Ring
Magnetic Stirrer with Electrode Arm
Vessel Heating / Cooling Accessory
pH Checker
Accessories
75
Conforms to the Specifications of:
ASTM D664, D2896, D3227, D4739
Principle: Volume determination by equivalence point, end point or pH STAT.
Control: Microcontroller based
mV range: ± 3200 mV.
Accuracy: ± 0.1 mV (± 0.0016 pH).
Amplifier input impedance: > 10 ohms
Burette Resolution: 1/5000 for 5 ml, 1/10000 for 10 ml, 1/5000 for 25 ml.
Filling time: Less than 20 seconds
Keyboard: Alphanumeric splash waterproof polyester soft keys.
Display: 40 x 2 line back lighted liquid crystal display (LCD).
Titration Head: Manual stand with swiveling arm.
Stirrer System: Microcontroller based variable speed, high torque vortex
stirrer with digital indication. (Magnetic Stirrer optional)
Sensors:
Electrodes for Potentiometric titration - (pH, Ion, Redox, Argentometric).
a) Any combination electrode. b) Differential Electrode System comprising
sensing (Indicator) Electrode with BNC Connector and Reference Electrode
with 4mm Banana Connector.
Electrode for KF/Voltametric titration with BNC/TNC Connectors.
Temperature sensor (PRT/PT100)
Calibration: 3-point Calibration with user entered buffer values
and standardization with 7 pH buffer.
End Point detection: a) Potentiometric b) Voltametric c) Thermometric
and Photometric.
Cut-off criteria: a) Volume b) End point c) mV/pH.
Methods:
Titrations:
a) Acid base b) Nonaqueous c) Redox d) Preciptiation
e) Complexometric f) back titration
KF titration (Optional)
Results: a) Molarity b) % Assay(wt), c) % volume (ml) d) ppm e) mg/l
f)mg/g g)g/l h) meq/l i) mol/kg j) TAN and TBN for oil samples.
Method Storage: 50 methods with parameters.
Titrant Molarity storage: 20 values
Input/Output Peripheral Interface:
(a) Parallel Port: 1 - for printer
(b) Serial Port: 2 - for Balance & PC
Electrical Requirements:
115V, 60Hz
230V, 50Hz
0-66-78_4c_GTE_Layout 1 10/24/12 11:06 AM Page 76
Heat of Combustion of Liquid Hydrocarbon Fuels
by Bomb Calorimeter
Specifications
Test Method
Conforms to the specifications of:
ASTM D240; D4809; D5865; D1989; D5468; E711; ISO 1928;
DIN 51900; BS1016
Measurement range: 40,000 J
Measuring mode: Isoperibolic 25°C; Isoperibolic 30°C;
Dynamic 25°C; Dynamic 30°C
Isoperibolic Measuring Time: Approximately 22 min
Dynamic Measuring Time: Approximately 7 min
Oxygen Operating Pressure: 30 bar
Cooling Medium: Water via line, flow through quantity 60 + 10 liters / hour
Water Operating Pressure: 1 – 1.5 bar max.
Water Test Pressure: 10 bar
Interfaces: Serial (RS232); Parallel; Keyboard; Sample rack; External monitor
Heat of combustion is determined in this test method by burning a weighed
sample in an oxygen bomb calorimeter under controlled conditions.
The heat of combustion is computed from temperature observations before,
during and after combustion with proper allowances for thermochemical
and heat transfer corrections. Either isothermal or adiabatic calorimeter
jackets can be used.
Automatic Calorimeter
The automatic calorimeter is the latest system for determining gross calorific
values of liquids and solid fuels. A higher level of automation with extremely
simple handling characterizes this device.
In addition to the Isoperibolic measurement procedure, a Dynamic
(reduced-time) mode is also available for the user. Different working
temperatures can be selected for both procedures based on the temperature
of the connected water.
To provide a supply of cooling water, the calorimeter can be connected to a
standard thermostat or an appropriate permanently installed water connection,
with a connection valve. The unit is equipped with a very convenient operating
panel through which operation of the device takes place. The graphical display
with active back lighting displays the appropriate status messages. The
temporal course of a measurement that has been started and all current
parameters of the weighed in sample can be constantly monitored and are
arranged to be clearly visible.
Connections for analysis scale, printer, sample rack for identifying and
managing samples are already integrated into the basic device. The
network connection and the special configuration for data exchange can be
implemented at any time with LIMS.
In combination with special halogen-resistant decomposition vessels
quantitative decompositions can be performed to determine halogen and
sulfur content.
Ordering Information
Catalog No.
K88800
K88890
Accessories
K88800-1
K88890-1
K88800-2
K88800-3
K88800-4
K88800-5
Dimensions lxwxh,in.(cm)
171⁄2x173⁄4x193⁄4 (440x450x500)
Automatic Calorimeter, 115V 60Hz
Automatic Calorimeter, 220V 50Hz
Cooling water supply unit, 115V 60Hz
Cooling water supply unit, 220V 50Hz
Pressure Gauge, Oxygen
To reduce the pressure of the oxygen cylinder to 30 bar
Standard Decomposition Vessel
Decomposition Vessel, Halogen Resistant
For quantitative decomposition determine halogen and
sulfur content
Connection valve
Required for permanently installed water connection
Net Weight: 66 lbs (30 kg)
Automatic Filter Plugging Tendency Analyzer (FPT)
Test Method
Determines the Filter Plugging Tendency (FPT) of distillate fuel oils where
the end use demands an exceptional degree of cleanliness. This test is
applicable to fuels within the viscosity range of 1.50 to 6.00 mm2/s (cSt) at
40°C. The test is not applicable to fuels that are not clear and bright
because water interferes with the measurement of filter plugging. Causes
of poor filterability might include fuel degradation products, contaminants
picked up during storage or transfer, or interaction of the fuel with the filter
media. Any of these could correlate with orifice or filter system plugging,
or both.
KLA-6 Automatic Filter
Plugging Tendency
Analyzer (FPT)
Automatic Filter Plugging Tendency Analyzer
• Integrated Cooling System equipped with a single stage gas motor
compressor CFC free
• Measuring device complete with support for filter, Beakers, PT100
sensor Class A, level sensor, pressure gauge, tubes and joints.
• Pump 20 mL/min
• 6.4” TFT/LCD built-in touch screen panel PC for the managing of the
analyzer by means of Lab-Link Software
• USB connection to an external printer or external PC
• Storage capacity for more than 60,000 analysis
Ordering Information
Catalog No.
KLA-6
KLA-6 (220)
Specifications
Conforms to the specifications of:
ASTM D2068; IP 387
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Automatic Filter Plugging Tendency Analyzer (FPT),
115V 60Hz
Automatic Filter Plugging Tendency Analyzer (FPT),
220-240V 50/60Hz
Accessories
KLA-1820-8013 Glass Fibre Filters, pk of 100
KLA-PT100-CAL Calibration Box and Cables
KLA-DB-KIT
Kit of Connectors and Cables for Cold range
76
0-66-78_4c_GTEaa2_Layout 1 11/29/12 6:29 PM Page 77
Oxidation Stability of Foods, Oils, Fats and Biodiesel Fuels
Test Method
For the determination of the oxidation stability of samples (solid, semisolid, or liquid), in order to determine product quality and obtain value
added information related to the fat oxidation processed in samples of foods,
oils, fats and Biodiesel Fuels.
Oxidation Test Reactor
The Oxidation Test Reactor is a versatile instrument suitable for a wide range
of oxidation stability and shelf-life applications including:
• Prediction of the oxidation stability during shelf-life studies, by analyzing
the product at defined time intervals and building an experimental curve
• Evaluation of the adequacy of storage conditions
• Evaluation of an optimal packaging solution
• Comparison of the oxidation stability of different formulas for food
preparations
• Evaluation of the oxidative stability of vegetable oils of different
botanical origin
• Evaluation of the effectiveness of antioxidants
• Information on product oxidation when the oxidation flex is not visible,
especially for products with a low fat content (4-5%). In this case, product
oxidation can be achieved by combining the Oxidation Test Reactor with
the gas chromatographic technique.
K83100 Oxidation Test Reactor
Specifications
Based on the Specifications of:
ASTM D942; IP 142
Temperature Range: Ambient to 110°C
Number of Oxidation Chambers: 2
Chamber Capacity: 100mL
Pressure Range: 0 – 8 bar
Interface: USB
Overpressure: Safety Valve
Out of Range Temperature: Visual Alarm
Damaged Probe: Visual Alarm
Electrical Requirements:
220-240VAC, 50/60Hz
The Oxidation Test Reactor is a complete solution, controlled entirely by the
Windows®-based oxidation software capable of providing high added value
information concerning fat oxidation processes in foods, oils, fats and
biodiesel fuels.
The Oxidation Test Reactor works directly on the whole sample without the
need for preliminary fat separation, and is suitable for the determination of the
quality and the state of preservation of the sample.
Included Accessories
Oxidation Software
USB Cable
Sample Holder (6)
Spacer (4)
An extremely simple and intuitive instrument equipped with two separate
titanium chambers in order to analyze the same sample in duplicate or
different samples at the same time, under the same conditions.
The stability of the sample is determined by accelerating the oxidation process
using high temperatures (from Ambient to 110°C) and a pre-determined
oxygen pressure. Oxygen is consumed during fat oxidation and it is this
decrease in oxygen pressure that enables us to obtain useful information
concerning the sample.
Dimensions wxdxh,in.(cm)
14.6 x 19.4 x 7.6 (36.5x48.5x19)
Net Weight: 36.3 lb (16.5 kg)
Ordering Information
The intuitive software controls the entire process in a user friendly way and the
operator can record data in a database, compare tests, export the data to an
Excel file, filter and order the data quickly and easily.
Catalog No.
K83100
77
Oxidation Test Reactor, 220-240V 50/60Hz
0-66-78_4c_GTE_Layout 1 10/24/12 11:06 AM Page 78
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Traces of Volatile Chlorides in
Butane-Butene Mixtures ........................................................Page 58
ASTM D2384
Aniline Point and Mixed Aniline Point of
Petroleum Products and Hydrocarbon Solvents ........Pages 42-43
Mercuric Thiocyanate
Potassium Nitrate
Saturated Calomel Electrolyte
Mercury-Calomel Mixture
Silver Nitrate
Gelatin
Acetone
Hydrochloric Acid
Perchloric Acid
Agar Powder
ASTM D611; IP 2, ISO 2977; DIN 51775; FTM 791-3601
Pipets, 10mL and 5mL
Laboratory Balance
Oven
Rubber Suction Bulb
Safety Goggles
Plastic Gloves
Aniline
Calcium Sulfate or Sodium Sulfate, anhydrous
n-Heptane
Air Supply (for Automatic Aniline Apparatus)
Nitrogen
Nitric Acid
Iron Wire
Hydrogen
Hydrogen Peroxide
Bromthymol Blue Indicator
Sodium Carbonate
Titration Equipment
Oxygen
Vacuum Source
Ramsbottom Carbon Residue
of Petroleum Products ...........................................................Page 59
ASTM D524; IP 14; ISO 4262; FTM 791-5002
Saybolt Color of Petroleum Products ....................Pages 44, 46-47
Desiccator
Strainer (100-mesh)
Analytical Balance
Calcium Chloride
Syringe
ASTM D156; DIN 51411; FTM 791-101
Acetone or other Solvent
Soap
Qualitative Filter Papers
Distilled Water
Sediment in Crude Oils and Fuel Oils
by the Extraction Method.......................................................Page 61
ASTM Color of Petroleum Products
(ASTM Color Scale).........................................................Pages 45-46
ASTM D473; IP 53; ISO 3735; DIN 51789; FTM 791-3002
ASTM D1500; IP 196; ISO 2049; FTM 791-102
Solvent Kerosene (for dark samples)
Distilled Water
Desiccator
Toluene
Analytical Balance
Distillation of Petroleum Products
at Reduced Pressures.....................................................Pages 53-54
Rust Protection by Metal Preservatives
in the Humidity Cabinet.........................................................Page 65
ASTM D1160
ASTM D1748; FTM 791-5310
Toluene
Cyclohexane
n-Tetradecane
1L Beaker
Boiling Chips
Silica Sand
Petroleum Naphtha
Precipitation Naphtha
Methyl Alcohol
Air Supply
Water Supply
Nitrogen
Balance
n-Hexadecane
Calcium Chloride
Silicone Fluids
Sulfur in Liquefied Petroleum Gases
(Oxy-Hydrogen Burner) ..........................................................Page 58
Freezing Point of Aqueous Engine Coolant Solution .......Page 68
ASTM D2784
ASTM D1177
Oxygen
Nitrogen
Acetone
Hydrogen Peroxide
Methylene Blue
Alcohol
Thorin
Perchloric Acid
Spectrophotometer
Sodium Hydroxide
Low Sulfur Acetone
Safety Shield
Glass Wool
Solid Carbon Dioxide
Liquid Nitrogen
Hydrogen
Sulfuric Acid
Isopropanol
Glycerin
Vacuum Source
Distilled Water
Carbon Dioxide
Barium Chloride Dihydrate
Denatured Ethyl Alcohol
Hydrochloric Acid
Barium Perchlorate
Fleisher’s Methyl Purple Indicator
78
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 79
Fuels
Test Methods
Page
Test Methods
Page
Oxidation Stability of Gasoline (Induction Period Method)
ASTM D525, D5304; IP 40; ISO 7536
DIN 51799, 51780; FTM 791-3352 ..................................................80-84
Antirust Properties of Petroleum Products Pipeline Cargoes
NACE TM 0172; ASTM D665, D6158, D3603; IP 135;
ISO 7120; DIN 51585; FTM 791-4011....................................................98
Oxidation Stability of Aviation Fuels (Potential Residue Method)
ASTM D873; IP 138; DIN 51799; FTM 791-3354 ............................80-84
Silver Corrosion by Aviation Turbine Fuels IP 227;
ASTM D130, D6074, D6158; FSPT DT-28-65; IP 154;
ISO 2160; DIN 51759; FTM 791-5325 ..................................................99
Assessing Distillate Fuel Storage by Oxygen Overpressure
ASTM D5304............................................................................................85
Existent Gum in Fuels by Jet Evaporation
ASTM D381; IP 131; ISO 6246; DIN 51784;
FTM 791-3302....................................................................................86-87
Cold Filter Plugging Point of Distillate Fuels
ASTM D6371; IP 309; DIN 51428 ........................................................100
Automated Cold Filter Plugging Point of Distillate Fuels
ASTM D6371; IP 309; EN 116 ..............................................................101
Accelerated Iron Corrosion in Petroleum Products
ASTM D7548............................................................................................88
Portable Octane Analyzer for Unleaded Gasolines
ASTM D2699, D2700 ..........................................................................102
Dew Point Apparatus ..............................................................................88
Density or Relative Density of Light Hydrocarbons by
Pressure Thermohydrometer
ASTM D1657; GPA 2140; IP 235; ISO 3993 ......................................103
Copper Strip Corrosion by Liquefied Petroleum (LP) Gases
ASTM D1838; GPA 2140; ISO 6251 ......................................................89
Copper Corrosion From Petroleum Products by the Copper Strip
Tarnish Test ASTM D130, D6074, D6158; FSPT DT-28-65;
IP 154; ISO 2160; DIN 51759; FTM 791-5325 ................................90-91
Vapor Pressure of Petroleum Products (Reid Method)
ASTM D323; GPA 2140; IP 69; ISO 3007; DIN 51616;
FTM 791-1201 ..................................................................................92-94
Hydrocarbon Types in Liquid Petroleum Products by Fluorescent
Indicator Absorption ASTM D1319; IP 156 ........................................104
Volatility of Liquefied Petroleum (LP) Gases
ASTM D1837, D2158; GPA 2140; ISO 13757......................................105
Residues in Liquefied Petroleum (LP) Gases
ASTM D2158; GPA 2140 ......................................................................105
Vapor Pressure of Liquefied Petroleum (LP) Gases (LP-Gas Method)
ASTM D1267; GPA 2140; IP 161; ISO 4256;
DIN 51754; FTM 791-1201 ..............................................................92-94
Filterability of Diesel Fuels by Low Temperature Flow Test (LTFT)
ASTM D4539 ........................................................................................105
Wax Appearance Point of Distillate Fuels ASTM D3117 ....................94
–Cloud Point and Pour Point of Petroleum Oils
–please refer to pages 132-133
–Oxidation Stability of Distillate Fuel Oil (Accelerated Method)
–please refer to pages 120-122
–Please refer to the Viscosity, Flash Point and General Tests Sections
–Additional test methods are available upon request
–please call or write for information
Smoke Point of Aviation Turbine Fuels
ASTM D1322; ISO 3014; IP 57; DIN 51406; FTM 791-2107 ................95
Freezing Point of Aviation Fuels ASTM D2386; IP 16; ISO 3013;
DIN 51421; FTM 791-1411 ....................................................................96
Automated Freezing Point of Aviation Fuels ASTM D2386; IP 16;
ISO 3013 ..................................................................................................97
For information on additional testing methods for fuels:
www.koehlerinstrument.com
0-79-95_5a_Fuelaa2_Layout 1 11/29/12 6:38 PM Page 80
Oxidation Stability of Gasoline and Aviation Fuels
Oxidation Stability of Gasoline
(Induction Period Method)
Oxidation Stability of Aviation Fuels
(Potential Residue Method)
Test Method
Provides an indication of the tendency of gasoline and aviation fuels to form
gum in storage. The sample is oxidized inside a stainless steel pressure
vessel initially charged with oxygen at 100psi (689kPa) and heated in a
boiling water bath. The amount of time required for a specified drop in
pressure (gasoline) or the amount of gum and precipitate formed after a
specific aging period (aviation fuels) is determined.
Oxidation Stability Test Apparatus
•
•
•
•
•
Conforms to ASTM D525, D873, ISO 7536 and related specifications
Oxidata® Pressure Measurement System
Available in two, four or six-unit configurations
Choice of water/liquid or solid block heating baths
Oxidation pressure vessel incorporates burst disk assembly
Consists of Oxidation Pressure Vessel, Pressure Measurement Equipment,
Oxidation Bath and Accessories.
Ordering Information
Oxidation Pressure Vessel
Oxidation Baths
Pressure Measurement Equipment
Accessories
K10500 Oxidation Pressure Vessel
page 80
pages 81-82
pages 83-84
pages 81-82
Oxidation Pressure Vessel
Precision machined stainless steel pressure vessel includes threaded
body; lid; stem with filler rod and mounting flange; needle valve for
purging, pressurizing and exhausting pressure vessel with oxygen; and
burst disk assembly. Pressure vessel interior and inside of stem have a
high polish to facilitate cleaning and prevent corrosion. Stainless steel
burst disk ruptures at 223psi (1537kPa) to prevent unsafe pressure
build-up inside pressure vessel. Octagonal sections on the pressure
vessel and lid permit tight closure with wrench. Includes buna-N gaskets.
See Accessories on pages 81-82 for available rupture disk assembly
retrofit for existing pressure vessels. Can also be used as a pressure
vessel in ASTM D5304 “Standard Test Method for Assessing Distillate
Fuel Storage Stability by Oxygen Overpressure”.
Ordering Information
Catalog No.
K10500
Oxidation Pressure Vessel
Oxidata® Pressure Measurement System
For Oxidata® specifications and ordering information refer to pages 83-84.
80
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 81
Oxidation Stability of Gasoline and Aviation Fuels
Solid Block Oxidation Baths
• Solid block baths conforming to ASTM and related specifications.
Constant temperature baths for heating K10500 Oxidation Pressure
Vessels in accordance with ASTM specifications.
Solid Block Baths–Insulated aluminum block baths available in two or
four-unit capacity. Baths feature microprocessor temperature control with
built-in overtemperature protection and dual LED displays for setpoint and
actual temperature values in °C/°F format. The solid block design offers
operating advantages over the boiling water bath, and meets temperature
control and other requirements of ASTM and related methods. It should be
noted, however, that many applicable specifications for this test method
call for a liquid bath medium. Housed in an insulated steel cabinet with
chemical-resistant polyurethane enamel finish. Includes lids for pressure
vessel ports. Order thermometer separately.
Communications software (RS232, etc.) ramp-to-set and other enhanced
features are available on the solid block and 4-6 place liquid baths as extra
cost options. Contact your Koehler representative for information.
Specifications
Conforms to the specifications of: ASTM D525, D873; IP 40, IP 138; ISO 7536;
DIN 51780, 51799; FTM 791-3352, 791-3354; NF M 07-012, 07-013
Maximum Temperature:
Solid Block Baths: 250°F (121°C)
K10491 Solid Block Oxidation Bath
Ordering Information
Solid block baths meet temperature control and other requirements of ASTM
and related methods. While the aluminum block design offers operating
advantages over the standard boiling water bath, it should be noted that many
applicable specifications for this test call for a liquid bath medium. Please refer
to the test method for the specific requirements.
Catalog No.
Accessories
K10540
K10540/C
K10510
Ordering Information
Catalog
No.
Type
Electrical
Requirements
Dimensions
Ixwxh,in.(cm)
K10551
0-1300W
15x10x17
(38x25x43)
K10556
0-2500W
24x10x17
(61x25x43)
K10401
Solid
Block
115V 60Hz
2
12A
K10491 vessels 220-240V 50/60Hz
6A
K10403
115V 60Hz
4
22A
K10493 vessels 220-240V 50/60Hz
11A
Heater
Range
K10520
K10530
≥
Software compatible, inquire
with Koehler Customer Service.
K10560
K10525
250-000-22F
250-000-22C
81
Glass Sample Container and Cover with pour out spout
Glass Sample Container Cover Only
Gasket. Replacement composition gasket for
K10500 Oxidation Pressure Vessel
Pressure Line. For pressurizing Oxidation Pressure Vessel.
6 ft. (1.83m) long, with quick release coupling for
needle valve on pressure vessel and threaded
fitting for oxygen tank
Oxygen Manifold Pressure Relief System
Connects to oxygen source to prevent overcharging of
vessel. Equipped with relief valve to vent at 125psi and
300 series stainless steel 150psi burst disk assembly.
Constructed from 300 series stainless steel. Cleaned for
oxygen service
Wrench. For tightening seal on Oxidation Pressure Vessel
Table Socket. Installs in benchtop to aid in
tightening seal on Oxidation Pressure Vessel
Bronze Tubing
For connecting pressure recorder to vessel.
Flexible seamless helical tubing with protective armor
braid and connections. 5 ft (1.52m) long
Burst Disk Assembly
Retrofit kit for Oxidation Pressure Vessel without
burst disk assembly
ASTM 22F Thermometer
Range: 204 to 218°F
ASTM 22C Thermometer
Range: 95 to 103°C
0-New CatalogPagesAA2_Layout 1 11/29/12 7:51 PM Page 3
Oxidation Stability of Gasoline and Aviation Fuels
Water/Liquid Oxidation Baths
• Water/liquid baths conforming to ASTM and related specifications.
Constant temperature baths for heating K10500 Oxidation Pressure
Vessels in accordance with ASTM specifications.
Water/Liquid Baths–Two different models, both equipped with low liquidlevel controllers in accordance with the latest ASTM specifications. Two-unit
analog controlled water bath can be flush mounted in a table top if desired,
and is equipped with an overflow standpipe/drain to maintain the proper
depth when the pressure vessels are inserted, and a plated brass reflux
condenser to minimize evaporation loss.
The six unit model can be used with water or oil as a bath medium, and
has microprocessor temperature control that provides quick temperature
stabilization without overshoot. Dual LED displays provide setpoint and
actual temperature values in °C/°F format. A built-in overtemperature control
circuit interrupts power should the bath temperature exceed a programmed
cut-off point. Both models feature double-wall insulated construction with
stainless steel tanks, support racks and port covers. Order thermometer
separately. The 6 unit model can be ordered with interchangeable racks for
performing the ASTM D942, ASTM D323 and D1298 test methods–please
contact your Koehler representative for additional information.
Communications software (RS232, etc.) ramp-to-set and other enhanced
features are available on the solid block and 4-6 place liquid baths as extra
cost options. Contact your Koehler representative for information.
K10404 Liquid Oxidation Bath with K10500 Pressure Vessels
Specifications
Ordering Information
Conforms to the specifications of: ASTM D525, D873; IP 40, IP 138; ISO 7536;
DIN 51780, 51799; FTM 791-3352, 791-3354; NF M 07-012, 07-013
Maximum Temperature:
2 Unit Water/Liquid Bath: boiling water
6 Unit Water/Liquid Bath: 250°F (121°C)
Catalog No.
Accessories
K10540
K10540/C
K10510
Solid block baths meet temperature control and other requirements of ASTM
and related methods. While the aluminum block design offers operating
advantages over the standard boiling water bath, it should be noted that many
applicable specifications for this test call for a liquid bath medium. Please refer
to the test method for the specific requirements.
K10551
K10556
Ordering Information
Type
Water/
Liquid
Catalog
Electrical
No.
Requirements
K10400
115V 60Hz
Analog
2
17.3A
K10402 vessels 220-240V 50/60Hz
Analog
9.0A
K10404
6
220-240V 50/60Hz
Digital vessels 18.1A
Heater
Range
Dimensions
Ixwxh,in.(cm)
0-2000W
24x14x24
(61x36x61)
K10520
K10530
0-3000W
24x14x291⁄2
(61x36x75)
K10560
K10525
250-000-22F
250-000-22C
Glass Sample Container and Cover with pour out spout
Glass Sample Container Cover Only
Gasket. Replacement composition gasket for
K10500 Oxidation Pressure Vessel
Pressure Line. For pressurizing Oxidation Pressure Vessel.
6 ft. (1.83m) long, with quick release coupling for
needle valve on pressure vessel and threaded
fitting for oxygen tank
Oxygen Manifold Pressure Relief System
Connects to oxygen source to prevent overcharging of
vessel. Equipped with relief valve to vent at 125psi and
300 series stainless steel 150psi burst disk assembly.
Constructed from 300 series stainless steel. Cleaned for
oxygen service
Wrench. For tightening seal on Oxidation Pressure Vessel
Table Socket. Installs in benchtop to aid in
tightening seal on Oxidation Pressure Vessel
Bronze Tubing
For connecting pressure recorder to vessel.
Flexible seamless helical tubing with protective armor
braid and connections. 5 ft (1.52m) long
Burst Disk Assembly
Retrofit kit for Oxidation Pressure Vessel without
burst disk assembly
ASTM 22F Thermometer
Range: 204 to 218°F
ASTM 22C Thermometer
Range: 95 to 103°C
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
82
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 83
Oxidation Stability of Gasoline and Aviation Fuels
Oxidata® Pressure Measurement Systems
• Electronic pressure measurement systems exclusively designed for ASTM
oxidation test methods
• Powerful Oxidata® software for Windows® environments
• Monitors up to twelve pressure and four temperature channels
• Automatic end-point detection
• Real-time average bath temperature display
• Can be installed to most manufacturer's fuels oxidation test apparatus
Complete electronic measurement systems for plotting pressure versus time
and temperature in oxidation testing of fuels. Each system includes
transducers, multiplexer, data acquisition card, software, and mounting and
connecting hardware. Systems are available in two, three and four pressure
vessel configurations, and additional channels can be added for up to a total
of twelve pressure and four temperature channels.
Koehler's pressure measurement systems for fuels oxidation testing features
Oxidata®, a high accuracy pressure measurement software package designed
exclusively for ASTM oxidation test methods. Designed to run in a Windows®
2000 or Windows XP environment, Oxidata® monitors up to twelve samples
simultaneously, with graphical or tabular display of results. Each channel can
be independently configured for any of the applicable ASTM standard test
methods without compromising the independence or accuracy of the other
channels. Independent start and stop times and user programmable end
points add even greater flexibility.
Oxidata® Features and Specifications
• On line, real time monitoring of up to twelve samples simultaneously –
results plot directly to the screen for instant monitoring or printout of results
• Automatic detection and reporting of break point and induction period
• Invalid test indication when a pressure leak is detected
• Menu options for fuels oxidation testing and other ASTM oxidation tests
• Programmable automatic end point detection with graphical and
tabular representation
• Each channel can be configured and operated independently with different
start/stop times and different ASTM test methods
• Zoom in feature allows for magnification of any plot sector on any channel
for a more detailed study
• Monitors and reports temperatures of as many as twelve pressure vessels
simultaneously using accessory RTD's, and calculates and displays average
temperature for each bath
• Exports data to spreadsheet programs such as Microsoft Excel®,
Lotus 1-2-3® etc.
• Temperature and pressure calibration capability
• Data is saved directly to the disk or hard drive during testing to prevent loss
of valuable data
• Operates in Windows® 2000 and Windows XP environments
The software plots your data on screen on line, real time, and automatically saves
your data on disk or to the hard drive during the test to prevent loss of valuable
data. Multiple display options include the ability to view the status of all twelve
pressure channels on screen simultaneously and then click on any one channel
for a graph display; or to view four channels in graphical format simultaneously.
Powerful program features allow you to change axes, have colored plot lines and
zoom in on a specific plot sector to view data in greater detail.
Included Accessories (for the pressure measurement systems)
Transducers (connects directly to pressure vessel)
USB interface
Multiplexer
Oxidata® software
RTD probe assembly (1)
Connecting cables and hardware
Computer Requirements
Processor: Intel® Pentium II or similar (minimum)
Memory (RAM): 256MB or higher
Speed: 500 MHz or higher
Windows® 2000 or higher
Disk Space: 15 MB free space (minimum)
Communications Port: One USB port
Other Software: Microsoft® Excel (97 or above)
One RS232 port for temperature controller (optional)
Oxidata® software automatically detects the break point and induction period.
83
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 84
Oxidation Stability of Gasoline and Aviation Fuels
Mechanical Pressure Measuring and Recording
Equipment
• One-pen or two-pen mechanical recorders
• Pressure gauge for aviation fuel tests
Mechanical Recorders—Spring-wound circular chart recorder measures
pressure inside oxidation pressure vessel for break point and induction period
determinations on gasoline. Housed in a steel case suitable for wall mounting.
Order accessory bronze tubing for connection to oxidation pressure vessel.
Suitable for oxygen service. Includes 100 24-hour charts.
Pressure Gauge for Aviation Fuel Tests—Suitable for testing of
aviation fuels according to ASTM D873. Range 0-200psi. Suitable for
oxygen service.
Ordering Information
Real-time plot screens display pressure versus time for up to twelve samples
simultaneously (four different test methods shown).
Catalog No.
Mechanical Recorders
K10570
One-Pen Recorder
K10580
Two-Pen Recorder
Pressure Gauge for Aviation Fuel Tests
K10590
Pressure Gauge
Accessories
308-000-005
Recorder Charts
Pack of 100
308-001-02R
Recorder Cartridge Pen, Red
(for use with K10570 Recorder)
308-001-02B
Recorder Cartridge Pen, Blue
(for use with K10570 and K10580 Recorders)
308-001-L2R
Recorder Cartridge Pen, Long Red
(for use with K10580 Recorder)
Ordering Information
Catalog No.
The ordering information below is for installation to existing Koehler
equipment. For other makes of equipment, a few basic hardware items may
also be required – please contact your Koehler representative for assistance.
Oxidata® Pressure Measurement System for Fuels Oxidation
K10504-XP
2-Unit System, 115V 60Hz
K10594-XP
2-Unit System, 220-240V 50/60Hz
K10505-XP
4-Unit System, 115V 60Hz
K10595-XP
4-Unit System, 220-240V 50/60Hz
K10506-XP
6-Unit System, 115V 60Hz
K10596-XP
6-Unit System, 220-240V 50/60Hz
Accessories
K10504-0-1
K70519
Transducer
RTD Kit, for monitoring the temperature of
an additional bath
84
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 85
Assessing Distillate Fuel Storage Stability
by Oxygen Overpressure
Test Method
Used for assessing potential storage stability of middle distillate fuels,
including fuels with or without stabilizer additives, and freshly refined or
previously stored fuels. The sample is aged in a pressurized vessel at
constant temperature for 16 hours and, after cooling, the total amount of
insoluble products is determined gravimetrically.
Pressure Vessel
• Conforms to the specification of ASTM D5304
• Four, Six and Ten unit models
Stainless steel pressure vessels accommodate multiple sample containers
for determining storage stability of fuels by the oxygen overpressure
method. Vessels meet all applicable ASME and ASTM safety requirements
for construction and working pressure and maximum operating temperature
and are equipped with pressure safety valves factory present at 200psi
(1,332kpa). Included with each model are a collapsible glassware rack that
installs and removes easily for cleaning, oxygen inlet and outlet valves with
quick disconnect fittings and charging hose, pressure gauge and
wide-mouth closure with viton O-ring seal.
Specifications
Conforms to the specifications of:
ASTM D5304
Capacity: Four, six or ten sample containers
Construction: 316 stainless steel, in accordance with ASME specifications
Working Pressure at 90˚C: Exceeds ASTM requirements
Safety Relief Valve Setting: 200psi (1,332kPa)
Pressure Gauge: 0-200psi
K10600 Pressure Vessel, 4 Unit
Ordering Information
Included Accessories
Glassware rack, hinged, for four, six or ten sample containers
Charging hose with pressure tight crimp and quick disconnect
Dimensions:
K10600: 81⁄2" high by 91⁄2" round
Net Weight: 14 lbs (6.4kg)
K10601/K10602: 151⁄2" high by 91⁄2" round
Net Weight: 17 lbs (8kg)
Catalog No.
K10600
K10601
K10602
Pressure Vessel, 4 Unit
Pressure Vessel, 6 Unit
Pressure Vessel, 10 Unit
K10540
Sample Container with lid
Accessories
Shipping Information:
K10600:
Shipping Weight: 17 lbs (8kg)
Dimensions: 2.6 Cu. Ft.
K10601/K10602:
Shipping Weight: 22 lbs (10kg)
Dimensions: 3.5 Cu. Ft.
85
Order Qty
1
0-79-95_5a_Fuelaa2_Layout 1 11/29/12 6:38 PM Page 86
Existent Gum in Fuels by Jet Evaporation
Test Method
Gum formed during fuel storage can deposit on induction system surfaces,
intake valves, stems and guides. To test for gum content, a 50mL sample
is evaporated in an aluminum block bath for a specified period under
controlled conditions of temperature and flow of air (aviation and motor
gasolines) or steam (aircraft turbine fuel).
Existent Gum Test Apparatus
Evaporates aircraft turbine fuel and motor and aviation gasoline samples under
controlled conditions in accordance with ASTM specifications. Consists of a
high temperature evaporation bath with 100mL test beakers and, for aircraft
turbine fuels, a steam generator and steam superheater.
Evaporation Baths
•
•
•
•
•
Conforming to ASTM D381 and related specifications
Choice of three-unit and six-unit models
Available with built-in steam superheater
Microprocessor programmable high accuracy temperature control
Built-in pressure regulators and air flowmeters
Electrically heated baths for determining existent gum in aircraft turbine
fuels by steam-jet evaporation and in motor and aviation gasolines by
air-jet evaporation. Fully insulated, aluminum block design assures safe,
efficient high temperature operation. Equipped with air/steam pressure
regulator with gauge and a flowmeter for adjusting air flow per ASTM
specifications. Stainless steel jets deliver air or steam flow to the test
wells through removable brass conical adapters. Microprocessor PID
control provides quick temperature stabilization without overshoot, and
the bath is protected by an overtemperature control circuit that interrupts
power should bath temperature exceed a programmed cut-off point. Dual
LED displays provide actual and setpoint temperature values in °C/°F
format. Communications software (RS232, etc.), ramp-to-set and other
enhanced features are available as extra cost options. Contact your
Koehler representative for information.
K33700 Existent Gum Evaporation Bath
Specifications
Conforms to the specifications of: ASTM D381; IP 131; ISO 6246; DIN 51784;
FTM 791-3302; NF M 07-004
Testing Capacity:
K33800 and K33700: 6 sample beakers
K33780 and K33781: 3 sample beakers
Maximum Temperature: 475°F (246°C)
Temperature Control Stability: ±1°F (±0.5°C)
Bath Configuration: machined aluminum block with multiple cartridge heaters
Heater Range:
K33800 and K33700: 0-3000W
K33780 and K33781: 0-1500W
Superheater: (Model K33800 only)
Superheating chamber and condensate trap constructed of stainless steel
Solid state thermoregulator (0-550°F) Heater Range: 0-1500W
Electrical Requirements:
K33700: 220-240V 50/60Hz, Single Phase, 13.6A
K33800: 220-240V 50/60Hz, Single Phase, 20.4A
K33780: 115V 60Hz, Single Phase, 13.0A
K33781: 220-240V 50/60Hz, Single Phase, 6.8A
Model K33800 with Built-in Superheater–Six-unit bath with a built-in
thermostatically controlled superheater which delivers dried steam to the bath
inlet for steam-jet method testing of aircraft turbine fuels. Has digitalindicating solid state bath temperature control with digital setpoint and display.
Model K33700–Six-unit bath without built-in superheater.
Model K33780–Three-unit bath without built-in superheater. All controls are
housed in the bath cabinet.
Included Accessories
Ordering Information
Catalog No.
K33800
K33700
K33780
K33781
Conical Brass Adapters for air/steam jets
Dimensions lxwxh,in.(cm)
Existent Gum Evaporation Bath,
6-Unit with Superheater,
220-240V 50/60Hz
Existent Gum Evaporation Bath,
6-Unit, 220-240V 50/60Hz
Existent Gum Evaporation Bath,
3-Unit, 115V 60Hz
Existent Gum Evaporation Bath,
3-Unit, 220-240V 50/60Hz
K33800: 321⁄2x20x20 (83x51x51)
K33780: 321⁄2x11x19 (83x28x48)
K33700: 28x20x16 (71x51x41)
Net Weight:
K33800: 230 lbs (104.3kg)
K33780: 85 lbs (38.6kg)
K33700: 203 lbs (92.1kg)
≥
Software compatible, inquire
with Koehler Customer Service.
86
Shipping Information
K33800
Shipping Weight: 313 lbs (142kg)
Dimensions: 17.2 Cu. ft.
K33780
Shipping Weight: 140 lbs (63.5kg)
Dimensions: 8.3 Cu. ft.
K33700
Shipping Weight: 271 lbs (123kg)
Dimensions: 13.7 Cu. ft.
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 87
Existent Gum in Fuels by Jet Evaporation
Steam Generator
•
•
•
•
For steam-jet method testing of aircraft turbine fuels
Meets output requirements of three-unit and six-unit evaporation baths
Electrically heated for clean, efficient operation and ease of installation
Meets applicable ASME, NEC standards; UL listed, CSA approved
Electrically heated boiler provides instantaneous and reserve steam capacity
for steam-jet evaporation tests. Easy to install and operate; electrical heating
eliminates the need for on-site fuel combustion. Requires only a water feed
source and electrical hook-up. Ruggedly constructed, with long life industrial
grade incoloy heating element. Includes a full range of safety features:
automatic water level control and low water cut-off; steam safety valve;
high-limit pressure cut-out with manual reset; steam pressure gauge.
Specifications
Output: 54.1 lbs steam/hr at 212°F
Bhp Rating: 1.83
kW Rating: 18
K33810 Steam Superheater
Dimensions lxwxh,in.(cm)
20x28x36 (51x71x91)
Net Weight: 185 lbs (83.9kg)
Accessories
Catalog No.
K33710
Shipping Information
Shipping Weight: 200 lbs (91kg)
Dimensions: 18 Cu. ft.
332-002-017
Ordering Information
250-000-03F
Catalog No.
K33850
Steam Boiler, 120/240V 60Hz, Three Phase
K33850/208601 Steam Boiler,
208V 60Hz, Single Phase, 87A
K33850/208603 Steam Boiler,
208V 60Hz, Three Phase, 50A
K33850/240601 Steam Boiler,
240V 60Hz, Single Phase, 75A
K33850/240603 Steam Boiler,
240V 60Hz, Three Phase, 43A
K33850/380603 Steam Boiler,
380V 50/60Hz, Three Phase, 27A
K33850/415503 Steam Boiler,
415V 50Hz, Three Phase, 25A
K33850/480603 Steam Boiler,
480V 60Hz, Three Phase, 22A
250-000-03C
K33810
Other electrical configurations for the Steam Boiler are available.
Please inquire with Koehler Customer Service for additional information.
Order Qty
Sample Beaker,
100mL spun copper, 50x78mm
6
Sample Beaker,
Borosilicate Glass, 100mL
ASTM 3F Thermometer
Range: 20 to 760°F
2
ASTM 3C Thermometer
Range: –5 to +400°C
Steam Superheater
Provides dry superheated steam for evaporation
baths not equipped with a built-in superheater. Use
together with an outside steam source for steam-jet
method testing of aircraft turbine fuels. Superheating
chamber and condensate trap are constructed
entirely of stainless steel. Solid state temperature
controller adjusts between 0-550°F. Equipped with
steam inlet and outlet connections and condensate
drain valve. Steel exterior has a chemical resistant
polyurethane enamel finish.
Dimensions 5x27x91⁄2" (13x70x24cm).
Shipping Weight: 23 lbs (10.4kg)
220-240V 50/60Hz, Single Phase, 6.8A
Test Apparatus for Steam Jet Method
Ordering Information
Catalog No.
K33800
K33850 Series
K33710
250-000-03F
250-000-03C
Order Qty
Existent Gum Evaporation Bath
1
Steam Boiler
1
Sample Beaker (or 332-002-017)
6
ASTM 3F Thermometer. Range: +20 to +215°F
2
ASTM 3C Thermometer. Range: –5 to +400°C
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
87
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 88
Determination of Accelerated Iron Corrosion
in Petroleum Products
Test Method
Accelerated Laboratory and Field Procedure for the determination of
corrosion of iron, in the presence of water, on samples such as gasoline and
gasoline blended with 10% ethanol, E10 (Specification D4814); gasolineblend components (except butane); diesel fuel and biodiesel B5, except
Grade No. 4-D (Specification D975); biodiesel B6 to B20 (Specification
D7467); diesel-blend component such as light cycle-oil; No.1 fuel oil, No.2
fuel oil (Specification D396); aviation turbine fuel (Specification D1655).
Accelerated Iron Corrosion Tester
•
•
•
•
•
Preset Temperature and RPM value in direct accordance with ASTM D7548
5” Touch Screen Control Display with Soft keys
4-position liquid bath
Integrated Timer
Small Footprint
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
ASTM D7548
Temperature Setting: 37.8°C (100°F)
Bath Tank Volume: 1.3 Gallons
Heating/Cooling: Peltier Regulating System
Stirring Speed: 100 RPM; 900 RPM
15x23x14 (38.1x58.5x35.5)
Net Weight: 35 lbs (15.9kg)
K30260 Accelerated
Iron Corrosion Tester
Ordering Information
Catalog No.
K30260
K30269
Accessories
Electrical Requirements
250-000-28F
250-000-28C
K30130
K30150
K30180
380-100-002
115V 60Hz
220-240V 50/60Hz
Included Accessories
5ml Syringe with 63.5mm (2.5 in) needle
Test Jar, 90 ml capacity, flat-bottom (4)
Corrosion Test Specimen Assembly (4)
Ethernet Crossover Cable (1)
Magnetic Stirrer Bar according to ASTM (5)
Accelerated Iron Corrosion Tester, 115V 60Hz
Accelerated Iron Corrosion Tester, 220-240V 50/60Hz
Temperature Probe (4)
Test Jar Cap (4)
Port Cover (4)
O-Ring (4)
2x Lighted Magnifying Lens (1)
ASTM 28F Thermometer, Range: 97.5 to 102.5°F
ASTM 28C Thermometer, Range: 36.6 to 39.4°C
Polishing Chuck
Drive Motor, 115V
Drive Motor, 230V
Silicone Carbide Abrasive Cloth Roll, C-100 grit Open
Mesh, 38mm width x 22.5m length
For Preliminary grinding and final polishing
of test specimens.
Water Vapor Content by Measurement of Dew Point Temperature
Test Method
Determines the water vapor content of gaseous fuels by measurement of the
dew point temperature, followed by calculation of the water vapor content.
Dew Point Apparatus
• Rugged construction
• Stainless steel sample chamber with incorporated “target mirror”
The Dew Point Apparatus consists of a closed stainless steel dew point
chamber containing a highly polished stainless steel “target mirror” and
sample inlet and outlet control valves. The chamber is chilled by refrigerant
following through the outer cooling jacket, preventing any refrigerant contact
with the test sample. The thermometer is inserted into the mirror support
structure, providing the temperature of the “target mirror.” As the sample
flows in the chamber and is deflected across the surface of the mirror, the
temperature at which condensation collects on the mirror is recorded as the
dew point of the sample.
K32230 Dew Point Apparatus
with Pressure Gauge and ASTM
33C Thermometer
Ordering Information
Catalog No.
K32230
Dew Point Apparatus
Order Qty
1
K32230-1
K32230-2
K32230-3
K32230-4
250-000-33F
250-000-33C
250-000-114F
250-000-114C
Pressure Gauge, 0 to 4 bar
Pressure Gauge, 0 to 40 bar
Pressure Gauge 0 to 70 bar
Pressure Gauge 0 to 140 bar
ASTM 33F Thermometer, range: –36.5 to +107.5°F
ASTM 33C Thermometer, range: –38 to +42°C
ASTM 114F Thermometer, range: –112 to +70°F
ASTM 114C Thermometer, range: –80 to +20°C1
Accessories
Specifications
Conforms to the specifications of: ASTM D1142; GPA
Dimensions lxwxh,in.(cm)
Shipping Information
31⁄2x6x123⁄4 (9x15x32.5)
Net Weight: 61⁄2 lbs (3kg)
Shipping Weight: 11 lbs (5kg)
Dimensions: 2.5 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
88
1
1
1
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 89
Copper Strip Corrosion by Liquefied Petroleum (LP) Gases
Test Method
Tests the corrosiveness of LPG to copper by immersion of a polished test
strip in the sample inside a test cylinder at elevated temperature. After one
hour the test strip is removed and compared against the ASTM Copper Strip
Corrosion Standards.
LPG Copper Strip Corrosion Test Apparatus
• Conforms to ASTM D1838 and related specifications
• Four-sample testing capability
Consists of LPG Corrosion Test Cylinders, Water Bath, Copper Strips,
Polishing Materials and the ASTM Copper Strip Corrosion Test Standards.
LPG Corrosion Test Cylinders–Stainless steel cylinder with 1⁄4" needle valves
for purging and admitting LPG samples. Dip tube with hook suspends copper
strip in sample. Knurled, threaded cap with O-ring gasket hand tightens to a
positive seal. Withstands hydrostatic test pressure of 1000 psig (6895kPa).
LPG Corrosion Test Water Bath–Thermostatically controlled water bath
submerges four LPG Corrosion Test Cylinders in an upright position.
Controls temperature at 100 ±1°F (37.8 ±0.5°C) per ASTM specifications.
Soxhlet reflux condenser and constant water level device maintain
proper working depth. Polished stainless steel inner wall and powder
coated steel outer wall construction. Fully insulated.
Ordering Information
Catalog No.
K40000
K39900
K39990
LPG Corrosion Test Cylinder
LPG Corrosion Test Water Bath,
115V 60Hz
LPG Corrosion Test Water Bath,
220-240V 50/60Hz
Order Qty
4
K39900 LPG Corrosion Test Bath
1
Accessories
K40200
K40100
K25100
380-240-001
380-150-000
380-150-001
K25000
K25090
250-000-12F
250-000-12C
Copper Strip for LPG
12.5x1.5-3.0x75mm with
3.2mm hole per ASTM specifications
Connecting Tubing
Sulfur-free plastic-lined tubing for connection of test
cylinder valve to sample source. With 1⁄4 " stainless
steel and aluminum connectors. 24" long
ASTM Copper Strip Corrosion Test Standards
Colored reproductions of tarnished strips
encased in a plastic plaque.
Silicone Carbide Paper, 240-grit
For polishing copper strips prior to testing.
Pack of 50 sheets
Silicone Carbide Grain, 150-grit
For final polishing of copper strips prior to testing.
1 lb package
Silicone Carbide Paper, 150-grit
For polishing copper strips prior to testing.
Pack of 50 sheets
Polishing Vise
Holds copper strip firmly in place without marring
the edges. Stainless steel, mounted on
a composition base
Multi-Strip Polishing Vise
Similar to K25000 but capable of holding four
strips at a time
ASTM 12F Thermometer. Range: –5 to +215°F
ASTM 12C Thermometer. Range: –20 to +102°C
4
1
K40000 LPG Corrosion Test Cylinder
1
Specifications
Conforms to the specifications of:
ASTM D1838; GPA 2140; ISO 6251
Water Bath Specifications:
Capacity: four (4) LPG Corrosion Test Cylinders
Maximum Temperature: 221°F (105°C)
Temperature Control Stability: ±1°F (±0.5°C)
Heater Range: 0-750W
Bath Medium: 3.8 gal (14.4L) Water
Electrical Requirements:
115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase, 3.4A
1
1
1
1
Shipping Information
Dimensions lxwxh,in.(cm)
Shipping Weight: 27 lbs (12.2kg)
Dimensions: 5.3 Cu. ft.
12x10x24 (30x25x61)
Net Weight: 19 lbs (8.6kg)
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
1
89
0-79-95_5a_Fuelaa_Layout 1 11/5/12 11:41 AM Page 90
Copper Corrosion from Petroleum Products
Test Method
The Copper Strip Tarnish Test assesses the relative degree of corrosivity of
petroleum products, including aviation fuels, automotive gasoline, natural
gasoline, solvents, kerosene, diesel fuel, distillate fuel oil, lubricating oil
and other products. A polished copper strip is immersed in 30mL of sample
at elevated temperature. After the test period, the strip is examined for
evidence of corrosion and a classification number from 1-4 is assigned
based on a comparison with the ASTM Copper Strip Corrosion Standards.
For aviation fuels and natural gasoline the sample tube is placed inside a
stainless steel bomb during testing.
Test Bomb Baths
Thermostatically controlled water bath immerses Copper Strip Corrosion Test
Bombs at the required depth per ASTM specifications. Use for testing aviation
gasoline, aviation turbine fuel and natural gasoline. Fully insulated, double-wall
stainless steel construction. Soxhlet reflux condenser and constant water level
device maintain proper working depth. Choice of four-bomb and eight-bomb
models. Optional removable test tube rack converts four-bomb model for
testing of products not requiring corrosion bomb.
K25330 Copper Strip Test Tube Bath
Specifications: Conforms to the specifications of: ASTM D130; IP 154
FSPT DT-28-65; ISO 2160; DIN 51759; FTM 791-5325; NF M 07-015
Testing Capacity:
K25310/K25319: four (4) copper strip corrosion test bombs
K25320/K25329*: eight (8) copper strip corrosion test bombs
*or sixteen (16) test tubes with optional test rack
(Catalog No. K25309) installed
Maximum Temperature: 221°F (105°C)
Temperature Control Stability: ±1°F (± 0.5°C)
Heater Range: 0-750W
Bath Medium: 5 gal (18.9L) water
Electrical Requirements:
115V 60Hz, Single Phase, 7.5A
220-240V 50/60Hz, Single Phase, 4A
Temperature Control: Analog
Test Tube Bath
Constant temperature bath immerses 17 test tubes for copper strip tarnish tests
of products not requiring a test bomb, including: diesel fuel, fuel oil, automotive
gasoline, Stoddard solvent, kerosene and lubricating oil. Microprocessor
temperature controller has °C/°F switchable digital setpoint and display.
Operator and equipment are protected by an overtemperature control circuit
which automatically interrupts power to the unit should bath temperature
exceed a programmed cut-off point. Communications software (RS232, etc.),
ramp-to-set and other enhanced features are available as extra cost options.
Contact your Koehler representative for information. Welded stainless steel
inner wall and powder coated steel outer wall construction with built-in
support rack. Fully insulated.
Specifications
Conforms to the specifications of: ASTM D130, D6074, D6158; FSPT
DT-28-65; IP 154; ISO 2160; DIN 51759; FTM 791-5325; NF M 07-015
Capacity: 17 test tubes
Maximum Temperature: 190°C (374°F)
Temperature Control Stability: ±1°C (±2°F)
Heater Range: 0-750W
Bath Medium: 5 gal (18.9L) water or high temperature heater transfer fluid
Electrical Requirements:
115V 60Hz, Single Phase, 7.5A
220-240V 50/60Hz, Single Phase, 4A
Temperature Control: Digital
Included Accessories
Rubber Stoppers for bomb openings (4)
Dimensions: lxwxh,in.(cm)
Shipping Information
4-bomb model: 12x10x21 (30x25x53)
8-bomb model: 16x111⁄2x21 (41x29x54)
Net Weight:
4-bomb model: 181⁄2 lbs (8.4kg)
8-bomb model: 24 lbs (10.9kg)
Shipping Weight:
4-bomb model: 41 lbs (18.6kg)
8-bomb model: 45 lbs (20.4kg)
Dimensions:
4-bomb model: 5.3 Cu. ft.
8-bomb model: 5.5 Cu. ft.
Ordering Information
Catalog No.
K25310
K25319
K25320
K25329
K25309
Bath for Copper Strip Corrosion Test Bombs, 4-Unit,
115V 60Hz
Bath for Copper Strip Corrosion Test Bombs, 4-Unit,
220-240V 50/60Hz
Bath for Copper Strip Corrosion Test Bombs, 8-Unit,
115V 60Hz
Bath for Copper Strip Corrosion Test Bombs, 8-unit,
220-240V 50/60Hz
Optional Test Tube Rack for 8-Bomb Bath
Dimensions: Ixwxh,in.(cm)
Shipping Information
151⁄2x121⁄2x14 (39x32x36)
Net Weight: 27 Ibs (12.2kg)
Shipping Weight: 45 Ibs (20.4kg)
Dimensions: 12.8 Cu. ft.
Ordering Information
Catalog No.
K25330
K25339
K25330-8B
K25330-4B-8T
K25330-6B-6T
Please refer to page 99 for photograph of K25310 Series Corrosion Baths.
≥
Software compatible, inquire
with Koehler Customer Service.
90
Copper Strip Test Tube Bath, 115V 60Hz
Copper Strip Test Tube Bath, 220-240V 50/60Hz
Optional test Bomb Rack
Optional Rack, 4-Bomb, 8- Tube
Optional Rack, 6-Bomb, 6-Tube
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 91
Copper Corrosion from Petroleum Products
Copper Strip Corrosion Test Bomb
Test Apparatus for Aviation Fuels and Natural Gasoline
• For aviation fuels and natural gasoline
Catalog No.
K25310
K25319
K25200
K25080
332-004-004
332-004-002
K25100
380-220-001
380-150-003
K25000
250-000-12F
250-000-12C
Precision machined stainless steel bomb inserts in copper corrosion bath
for testing aviation fuels and natural gasoline. Withstands test pressure
of 100psi (689kPa) per specifications. Threaded cap with O-ring gasket
and knurled circumference tightens by hand to a positive seal. A 1⁄8"
groove in the bomb threads permits safe, gradual release of pressure
when opening the bomb.
Specifications
Conforms to the specifications of:
ASTM D130, D6074, D6158; IP 154; ISO 2160; DIN 51759; FTM 791-5325;
NF M 07-015
Net Weight: 1 lb (.45kg)
Order Qty
Bath for Copper Strip Corrosion Test Bombs, 115V
1
Bath for Copper Strip Corrosion Test Bombs, 220-240V
Copper Strip Corrosion Test Bomb
4
Copper Strips
4
Test Tube
4
Viewing Test Tube
4
ASTM Copper Strip Corrosion Standard
1
Silicone Carbide Paper, FEPA Grade, 220 grit
1
Silicone Carbide Grain, FEPA grade, 150 grit
1
Polishing Vise
1
ASTM 12F Thermometer
1
ASTM 12C Thermometer
Shipping Information:
Test Apparatus for Diesel Fuel, Fuel Oil, Automotive Gasoline, Stoddard
Solvent, Kerosene, Lubricating Oil and Biodiesel
Shipping Weight: 2 lbs (.91kg)
Ordering Information
Catalog No.
K25200
Catalog No.
K25330
Copper Strip Corrosion Test Bomb
Accessories
K25080
332-004-004
332-004-002
K25100
380-220-001
380-150-003
K25000
K25090
250-000-12F
250-000-12C
K25080
332-004-004
332-004-002
K25100
380-220-001
380-150-003
K25090
250-000-12F
250-000-12C
Copper Test Strip
12.5x1.5-3.0mm x 75mm to ASTM specifications
Test Tube
25 x 150mm
Viewing Test Tube
Protects copper strip during inspection or storage
ASTM Copper Strip Corrosion Standards
Colored reproductions of tarnished strips encased
in a plastic plaque
Silicone Carbide Paper, FEPA Grade, 220 grit
For polishing of copper strips prior to
testing - Pack of 50 sheets
Silicone Carbide Grain, FEPA grade, 150 grit
For final polishing of copper strips prior
to testing - 1 lb package
Polishing Vise
Holds copper strip firmly in place without marring the
edges. Stainless steel, mounted on a composition base
Multi-Strip Polishing Vise
Similar to K25000 but capable of holding four strips at a time
ASTM 12F Thermometer. Range: –5 to +215°F
ASTM 12C Thermometer. Range: –20 to +102°C
Copper Strip Test Tube Bath, 115V
(or K25339 Bath, 220-24OV)
Copper Strips
Test Tube
Viewing Test Tube
ASTM Copper Strip Corrosion Standard
Silicone Carbide Paper, FEPA Grade, 220 grit
Silicone Carbide Grain, FEPA grade, 150 grit
Multi-Strip Polishing Vise
ASTM 12F Thermometer
ASTM 12C Thermometer
Silver Corrosion Test
Please refer to page 99 for information.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
K25200 Copper Strip Corrosion Bomb with K25100 and K25080
91
Order Qty
1
17
17
17
1
1
1
1
1
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 92
Vapor Pressure of Petroleum Products and LP Gases
Vapor Pressure of Petroleum Products (Reid Method)
and Liquefied Petroleum Gases (LPG Method)
Test Method
Vapor pressure is a critical factor in the handling and performance of liquid
petroleum and liquefied petroleum gas (LPG) products. The vapor pressure
of automotive gasolines is subject to governmental regulation for pollution
control purposes.
Reid Vapor Pressure Cylinders
• Conform to ASTM D323, D1267 and related specifications
• One-opening and two-opening types
Polished stainless steel test cylinders for vapor pressure tests of liquid
petroleum products, volatile crude oil and liquefied petroleum gas (LPG).
Consists of upper chamber and lower chamber in required 4:1 volume ratio.
O-ring gaskets provide tight seal between chambers and at gauge coupling.
One-opening type is for gasoline and other products having a Reid Vapor
Pressure below 26psi (180kPa). Two-opening type is for liquid products
having a Reid Vapor Pressure above 26psi (ASTM D323) and for LPG (ASTM
D1267). Lower chamber of two-opening apparatus includes straight-through
ball valve and 1⁄4" needle valve. For LPG testing, order two-opening type
apparatus and accessory bleeder valve assembly.
Specifications:
Conforms to the specifications of: ASTM D323, D1267; GPA 2140; IP 69, 161;
ISO 3007, 4256; DIN 51616, 51754; FTM 791-1201
Hydrostatic Test (two-opening type): Withstands 1000psi (6894kPa) gauge
hydrostatic pressure per ASTM D1267 specifications
Included Accessories
Threaded 1⁄4" Gauge Coupling
O-ring Seals (2)
Shipping Information
Shipping Weight: 7 lbs (3.2kg)
Ordering Information
K11500
Catalog No.
K11500
Reid Vapor Pressure Cylinder, One-Opening Type
K11201
Reid Vapor Pressure Cylinder Two-Opening Type
K11202
Bleeder Valve Assembly for LPG tests for K11201 test cylinder
K11201
Reid Vapor Pressure Gauges
• Conforming to ASTM D323, D1267 and related specifications
• Dual psi/kPa scale on a 41⁄2" diameter dial
• Accurate to within 0.5% of scale range
• Micrometer adjustable pointer
Ruggedly constructed Bourdon type gauge designed especially for the Reid Vapor
Pressure test. Heavy duty rotary brushed stainless steel movement. Lightweight
aluminum case with corrosion-resistant finish and heavy duty brass nonsparking handle. Includes blow-out disc and 1⁄4" NPT male thread connection.
Ordering Information
Catalog
No.
311-005-004
311-015-002
311-030-002
311-060-002
311-100-002
311-250-001
311-600-003
311-060-002 RVP Gauge
92
Range
psi/kPa
0-5/35
0-15/100
0-30/200
0-60/400
0-100/700
0-250/1750
0-600/4200
Figure
Intervals
psi/kPa
0.5/5
1.0/10
5.0/20
5.0/50
10/50
25/100
50/250
Interval
Graduations
psi/kPa
0.05/0.2
0.1/1.0
0.5/2.0
0.2/2.5
0.5/2.5
1.0/20
2.0/25
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 93
Vapor Pressure of Petroleum Products and LP Gases
Wireless Reid Vapor Pressure Data Acquisition System
Windows®-based electronic pressure measurement software designed
for ASTM Reid Vapor Pressure test methods. Monitors up to eight pressure
vessel channels, graphing pressure and RVP data in real-time for each
channel. Each channel can be run independently and configured for the
pressure ranges of 0-50, 0-200, and 0-1000 psi. Pressure values can be
reported in psi or kPa. Software automatically exports results into Microsoft®
Excel for data analysis and storage.
Ordering Information
Catalog No.
K11401
K11491
Order Qty
RVP Data Acquisition System, 115V 60 Hz
1
RVP Data Acquisition System, 230V 50/60 Hz
Includes software, multiplexer box, USB converter box
and RTD temperature probe.
Requires one pressure transducer for each pressure vessel.
K11404-50
K11404-200
K11404-1000
RVP Pressure Transducer, 0-50 psi
RVP Pressure Transducer, 0-200 psi
RVP Pressure Transducer, 0-1000 psi
1-8
1-8
1-8
Reid Vapor Pressure Data Acquisition System
4 Unit Reid Vapor Pressure Bath
21-Unit Reid Vapor Pressure Bath
• Conforms to ASTM D323, D1267 and related specifications
• Free standing or flush-mount benchtop installation
• Microprocessor programmable high accuracy temperature control
Constant temperature water baths designed for Reid Vapor Pressure
determinations of liquid petroleum products and liquefied petroleum gases
(LPG). Immerses vapor pressure apparatus at the proper depth per ASTM
specifications. Controls bath temperature with ±0.2°F (±0.1°C) precision.
Microprocessor PID control provides quick temperature stabilization without
overshoot, and the bath is protected by an overtemperature control circuit
that interrupts power should bath temperature exceed a programmed cut-off
point. Dual LED displays provide actual and setpoint temperature values in
°C/°F format. Double-wall construction with fiberglass insulated stainless
steel tank. A sturdy 1" (25mm) flange permits flush-mount benchtop
installation for easy access to the bath interior. Built-in holders suspend test
cylinders at the required depth. Equipped with overflow stand pipe/drain.
• Conforms to ASTM D323, 1267 and related specifications
• Digital electronic temperature control
• Automatic water level control maintains proper immersion depth
Constant temperature water bath immerses twenty-one test cylinders for
vapor pressure tests on liquid products and liquefied petroleum gas (LPG).
Electronic level control automatically maintains the proper immersion depth
per ASTM specifications. Heating system employs a 6kW stainless steel heat
exchanger with a heavy duty circulating pump to provide rapid heat-up, even
heat distribution and ease of servicing. Convenient digital setpoint and display
permits rapid selection of any bath liquid temperature within the operating
range. A built-in overtemperature limit control protects against accidental
overheating. Bath interior and internal components are constructed of heavy
gauge stainless steel. Control panel is shielded by a hinged acrylic cover.
Includes sturdy angle-iron base with corrosion resistant polyurethane finish.
Order pressure gauges and cylinders separately.
Specifications
Specifications
Conforms to the specifications of:
ASTM D323, D1267; GPA 2140; IP 69, 161; ISO 3007, 4256;
DIN 51616, 51754; FTM 791-1201; NF M 07-007, 41-010
Capacity: 1 to 4 vapor pressure apparatus, one- or two-opening type
Temperature Control Stability: ±0.2°F (±0.1°C)
Maximum Temperature: 212°F (100°C)
Bath Medium: 13.7 gal (51.9L) water
Electrical Requirements:
115V 60Hz, Single Phase, 18.8A
220-240V 50/60Hz, Single Phase, 9.4A
Conforms to the specifications of: ASTM D323, D1267; GPA 2140;
IP 69, 161; ISO 3007, 4256; DIN 51616, 51754; FTM 791-1201
Testing Capacity: 21 vapor pressure test cylinders
Temperature Range: 212°F (100°C)
Temperature Control Stability: ±0.2°F (±0.1°C)
Heater Range: 0-6000W
Bath Medium: 58 gal (219.5L) water
Electrical Requirements:
220-240V 50Hz, Single Phase, 28A
220-240V 60Hz, Single Phase, 28A
Dimensions lxwxh,in.(cm)
Shipping Information
15x15x36 (38.1x38.1x91.5)
Net Weight: 67 lbs (30.4kg)
Shipping Weight: 105 lbs (47.7kg)
Dimensions: 14 Cu. ft.
Dimensions lxwxh,in.(cm)
Overall: 48x22x36 (122x56x91)
Ordering Information
Catalog No.
K11415
K11416
Ordering Information
Catalog No.
K11450
K11459
Reid Vapor Pressure Bath, 4-Unit, 115V 60Hz
Reid Vapor Pressure Bath, 4-Unit, 220-240V 50/60Hz
Photograph, thermometers, and additional accessories for
Reid Vapor Pressure testing appear on page 94.
93
Reid Vapor Pressure Bath, 21-Unit, 220-240V 50Hz
Reid Vapor Pressure Bath, 21-Unit, 220-240V 60Hz
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 94
Vapor Pressure of Petroleum Products and LP Gases
Accessories
Catalog No.
250-000-18F
250-000-18C
250-000-65F
250-000-65C
K11800
K11810
371-000-002
K112B-1-0-12
AS568-210
AS568-113
K40100
K11459 Reid Vapor Pressure Bath
Test apparatus for liquid products (ASTM D323) requires:
Test Cylinders, one or two-opening type
Pressure Gauges
Constant Temperature Bath
Bath Thermometer
Sample Container with Cover Assembly
Transfer Connection
Manometer
Manometer Adapter Kit
On-line version of this product is available. Please contact Koehler Customer
Service for additional information.
Ordering Information
ASTM 18F Thermometer
Range: 94 to 108°F
ASTM 18C Thermometer
Range: 34 to 42°C
ASTM 65F Thermometer
Range: 122 to 176°F
ASTM 65C Thermometer
Range: 50 to 80°C
Sample Container with Cover Assembly
Transfer Connection
Consists of threaded brass cap, delivery tube and
sampling tube. Use for removing liquid from the
sample container in accordance with ASTM
specifications
Liquid Manometer
Graduated in inches (0.1" div.).
For checking pressure gauge reading of up to 15psi
Manometer Adapter Kit
Kit for attaching pressure gauge to liquid manometer
for pressure verification
O-ring Seal
For coupling between air and gas chambers on
K11500 and K11201 vapor pressure bombs
O-ring Seal
For gauge and bleeder valve assembly connections
on K11500 and K11201 vapor pressure bombs
Flexible Tubing
Sulfur-free plastic lined tubing with 1⁄4" stainless
steel and aluminum connectors.
For charging LPG test cylinder.
Test apparatus for liquefied petroleum gases (ASTM D1267) requires:
Test Cylinders, two-opening type
Bleeder Valve Assemblies
Pressure Gauges
Constant Temperature Bath
Bath Thermometer
Flexible Tubing
Manometer
Manometer Adapter Kit
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Wax Appearance Point of Distillate Fuels
Test Method
Ordering Information
Detects the formation of wax crystals in burner fuels, diesel fuels and
turbine engine fuels at low temperatures. The sample is cooled at a
specified rate while being agitated. The temperature at which wax first
appears is the wax appearance point.
Catalog No.
K29760
K29768
Wax Appearance Point Apparatus
K29769
• Conforms to ASTM D3117 specifications
For detection of separated solids in burner fuels, diesel fuels and turbine engine
fuels. Similar to K29700 Freezing Point Apparatus. Includes jacketed sample
tube, motorized stirrer assembly, outer vacuum flask, clamps and stand.
Electrical Requirements:
115V 60Hz
220-240V 50Hz
220-240V 60Hz
250-000-06F
250-000-06C
Order Qty
Wax Appearance Point Apparatus,
115V 60Hz
1
Wax Appearance Point Apparatus,
220-240V 50Hz
Wax Appearance Point Apparatus,
220-240V 60Hz
ASTM 6F Thermometer. Range: –112 to +70°F
1
ASTM 6C Thermometer. Range: –80 to +20°C
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
94
0-79-95_5a_Fuel_Layout 1 10/24/12 11:10 AM Page 95
Smoke Point of Kerosene and Aviation Turbine Fuel
Test Method
Smoke point is an indicator of the combustion qualities of aviation turbine
fuels and kerosene. The fuel sample is burned in the Smoke Point Lamp,
and the maximum flame height obtainable without smoking is measured.
Smoke Point Lamp
• Conforms to ASTM D1322 and related specifications
Burns fuel samples under controlled conditions for smoke point
determinations of aviation turbine fuels and similar products. Consists of
brass lamp body with chimney; gallery; 0-50mm black glass scale with
white markings; brass plated door with curved glass window; candle
socket; and plated brass candle with wick tube and air vent. Mounted on
a cast iron base with aluminum support rod.
Ordering Information
Catalog No.
K27000
Smoke Point Lamp
Order Qty
1
Accessories
K27021
K27020
K27050
K27060
K27065
K27010
Extracted Cotton Wicks
Prepared in accordance with
ASTM D1322 (9.2) requirements.
Packed in a sealed tube with desiccant.
Case of 12
Cotton Wicks, pack of 12
Sighting Device
1
Installs on chimney of Smoke Point Lamp.
Eliminates parallax
Wick Insertion Tool
1
Facilitates insertion of cotton wick into wick tube
Wick Trimmer
1
Use together with K27060 Insertion Tool
to place wick at the correct height in
the wick tube, free of twists and frayed ends.
Interchangeable Candle
K27000 Smoke Point Apparatus with K27050 Sighting Device
and K27060 Wick Insertion Tool
Specifications
Conforms to the specifications of:
ASTM D1322; ISO 3014; IP 57;
DIN 51406; FTM 791-2107; NF M 07-028
Included Accessories
Cotton Wicks, non-extracted (6)
Interchangeable Candle
Automatic Smoke Point Apparatus available. Inquire with
Koehler Customer Service.
Dimensions dia.xh,in.(cm)
7x181⁄2 (18x47)
Net Weight: 10 lbs (4.5kg)
Shipping Information
Shipping Weight: 16 Ibs (7.3kg)
Dimensions: 5 Cu. ft.
95
0-96-106_5b_Fuel_Layout 1 10/24/12 11:14 AM Page 96
Freezing Point of Aviation Fuels
Test Method
The freezing point of an aviation fuel is the lowest temperature at which
the fuel remains free of solid hydrocarbon crystals that can restrict the flow
of fuel. The temperature of the fuel in the aircraft tank normally falls
during flight depending upon aircraft speed, altitude, and flight duration.
The freezing point of the fuel must be lower than the minimum operational
tank temperature. The test determines the temperature below which solid
hydrocarbon crystals form in aviation fuels. The sample is cooled with
continuous stirring in a Dewar-type sample tube until crystals appear.
Refrigerated Freezing Point Bath
•
•
•
•
•
•
Redesigned constant temperature bath for freezing point determinations on
fuel samples at temperatures as low as –100°F (–73°C). Accommodates
K29700 Freezing Point Apparatus and accessory stirrer. Microprocessor PID
circuitry provides precise, reliable temperature control within ASTM specified
tolerances. Simple push button controls and dual digital displays permit easy
setting and monitoring of bath temperature. Bath medium is contained in a
clear, evacuated Dewar flask, and glare-free fluorescent backlighting provides
excellent visibility when working with the freezing point samples. Air-cooled
hermetic compressors provide efficient operation with the use of CFC-free
refrigerants. Temperature control uniformity is assured by means of a
motorized stirrer which provides complete circulation without turbulence.
Cabinet construction is polyester-epoxy finished steel with a chemical-resistant
composite top surface. Working (top) surface includes port and mounting
plate for K29700 Freezing Point Apparatus and accessory stirrer. Bath rests on
adjustable leveling feet.
K29790 Freezing Point Bath with Freezing Point Apparatus and Stirrer
Ordering Information
Catalog No.
K29790
K29795
K29796
K29700
K29750-1-7
K29758-0-7
K29759-1-7
Refrigerated Freezing Point Bath
115V 60Hz, Single Phase, 18.3A
Refrigerated Freezing Point Bath
220-240V 50Hz, Single Phase, 10.0A
Refrigerated Freezing Point Bath
220-240V 60Hz, Single Phase, 10.0A
Freezing Point Apparatus, ASTM D2386
Stirrer Motor, 115V 60Hz
Stirrer Motor, 220-240V 50Hz
Stirrer Motor, 220-240V 60Hz
Order Qty
1
Specifications
1
1
Conforms to the specifications of:
ASTM D2386; IP 16; ISO 3013; DIN 51421; FTM 791-1411; NF M 07-048
Temperature Range: Ambient to –100°F (–73°C)
Temperature Control Accuracy and Uniformity: Exceeds ASTM requirements
throughout the operating range
Display: 0.1°C/°F resolution
Accessories
250-000-114C
K29720
K29721
Improved design with enhanced performance and safety features
Operating range to –100°F (–73°C)
Microprocessor PID digital temperature control
Dual digital displays show setpoint and actual bath temperature
Selectable temperature scale – Fahrenheit or Celsius
Conforms to ASTM D2386 and related specifications
ASTM 114C Thermometer. Range: –80 to +20°C 1
Moistureproof Collar, Type A
Use in place of brass packing gland to prevent
condensation of moisture.
Moistureproof Collar, Type B
Use to prevent condensation.
Electrical Requirements:
115V, 60Hz, Single Phase, 18.3A
220-240V, 50Hz, Single Phase, 10.0A
220-240V, 60Hz, Single Phase, 10.0A
Dimensions lxwxh,in.(cm)
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
35x26x31 (89x66x78.75)
Net Weight: 259 lbs (117.75kg)
≥
Shipping Information
Software compatible, inquire
with Koehler Customer Service.
Shipping Weight: 373 lbs (169.5kg)
Dimensions: 233⁄4 Cu.ft.
96
0-96-106_5b_Fuelaa3_Layout 1 11/29/12 6:45 PM Page 97
Automated Freezing Point of Aviation Fuels
Test Method
Determines the temperature below which solid hydrocarbon crystals may
form in aviation turbine fuels and aviation gasoline. The freezing point of an
aviation fuel is the lowest temperature at which the fuel remains free of solid
hydrocarbon crystals that can restrict the flow of fuel through filters if present
in the fuel system of the aircraft. The temperature of the fuel in the aircraft
tank normally decreases during flight depending on aircraft speed, altitude,
and flight duration. The freezing point of the fuel must always be lower than
the minimum operational fuel temperature.
Automatic Freezing Point Analyzer with Integrated Panel PC
• Conforms to ASTM D1177, D1655, D2386, D5901, D5972 and related
specifications
• Stand alone system with Integrated Touch Screen Panel PC
• Direct Cooling system eliminates the need for solvent cooling baths
• One-stage cooling system provides temperatures as low as -45°C and
a two-stage cooling system down to -80°C
• Freezing Point measured by light pulsed emission on I.R spectrum through
a coaxial fiber optic with mirror
The freezing point detection system provides automated sample testing with the
accuracy and repeatability in accordance with ASTM D1177, D1655, D2386,
D5901, D5972 and related international specification. The sample is cooled in the
test chamber with constant stirring. The sophisticated dynamic measurement
system emits a light pulse every 0.5°C from a coaxial fiber optic cable positioned
above the test sample. The light pulse is then reflected off the mirror of the fiber
optic to an optical sensor. The advanced software package analyzes the response
of the light pulse. The initial appearance of crystallization is monitored by light
scattering. The sample is then warmed up, and the temperature at which the
hydrocarbon crystals disappear is recorded as the freezing point. All clear and
transparent fuels are readily measured by the detection system, regardless of
sample color.
Integrated Panel PC and Software Package–The Automated Freezing Point
Analyzer is a complete standalone system featuring an integrated panel PC with
an advanced software package. The 6.4” TFT/LCD touch screen display has a
resolution of 640x480 with a 262K color scheme. All analytical parameters are
graphed and displayed in real time as well as recorded in Microsoft® Excel
compatible file format. The software monitors the operation and performance of
all the analyzer components for proper data measurement, including the solenoid
valves, cooling system, pressure sensors, and the Platinum resistance PT100
Class A temperature probe.
Cooling System–For various user applications, the automated freezing point
system is available with either one-stage cooling for temperatures as low as
-45°C or two-stage cooling for temperatures as low as -80°C. The direct cooling
system features integrated gas CFC free motors compressors thus eliminating
the need for a solvent cooling bath. The direct system is capable of rapid cooling,
approaching -80°C bath temperatures in approximately 15 minutes, and utilizes
less electricity than standard cooling systems. The rapid cooling feature
combined with a consistent cooling profile system provides repeatable results
with high test reproducibility.
KLA-5-TS Automatic Freezing Point Analyzer with integrated touch screen PC
Multiple Configuration System–These automated sample cooling and
physical property measurement systems can be configured with one, two,
three, four and six test positions with one of five possible analytical heads at
each position: cloud point, pour point, cloud & pour point, cold filter plugging
point and freezing point. Standard and customized multiple configuration
systems are readily available.
Specifications
Conforms to the specifications of:
ASTM D1177, D1655, D2386, D5901 (Withdrawn 2010); IP 16; ISO 3013
Temperature Range:
One-Stage: +30 to -45°C
Two-Stage: +30 to -80°C
Resolution: 0.06°C
Accuracy: ±0.1°C
Repeatability / Reproducibility: as per standard test methods or better
Data Storage: > 60,000 analyses
Electrical Requirements:
115V ± 15% / 60Hz
220V ± 15% / 50 to 60Hz
Dimensions WxDxH,in.(cm)
26 x 233⁄4x 311⁄2 (66x60x80)
Net Weight: 176.5 lbs (80kg)
Ordering Information
Catalog No.
KLA-5-TS
Automatic Freezing Point Analyzer with Touch Screen,
(One-stage)
KLA-5-TS/2
Automatic Freezing Point Analyzer with Touch Screen,
(Two-stage)
Please specify voltage requirements when ordering.
Safety Features
• Audible alarm and displayed messages (at the end of the analysis and
in case of errors and/or malfunctions)
• Pressure controller for 1st and 2nd stage motor compressor
• Thermostat for 2nd stage activation
• Thermo-switch for each cooling / heating jacket
• Motor compressors equipped with internal overload devices
Accessories
KLA-PT100-CAL
KLA-DB-KIT
Certified Calibration Decade Box - PT100 Simulator
Set of Connectors and Cables
Extended Cooling Range down to -100˚C Available Upon Request.
97
0-96-106_5b_Fuel_Layout 1 10/24/12 11:14 AM Page 98
Antirust Properties of Petroleum Products Pipeline Cargoes
Test Method
Used to control corrosion in product pipelines caused by moisture
condensed from gasoline and distillate fuels. Antirust properties are
determined by immersing a polished steel test specimen in a stirred
mixture of the sample and distilled water held at constant temperature.
Rust Preventing Characteristics Oil Bath
• Conforms to NACE TM-01-72, ASTM D665* and D3603* specifications
• Accommodates six sample beakers
• Microprocessor temperature control with digital display
and overtemperature protection
Six-place constant temperature bath with stirrers for rust preventing
characteristics tests. Stirs sample-water mixtures at 1000rpm and controls
temperature with ±0.5°C (±1°F) stability. Immerses test beakers at the proper
depth per NACE specifications. Microprocessor temperature control has
°C/°F switchable digital setpoint and display. Operator and equipment are
protected by an overtemperature control circuit which automatically
interrupts power to the unit should bath temperature exceed a programmed
cut-off point. Stainless steel stirrer paddles are driven at 1000rpm by an
improved pulley drive-roller bearing arrangement. Paddles move to a raised
position for placement of sample beakers in the bath. Stainless steel bath
includes perforated support shelf for beakers and cover plate. Long lasting
polyester drive belt improves reliability. Drive train components are protected
by a removable steel guard. All exterior surfaces have stainless steel or
chemical resistant polyurethane enamel finishes.
K30160NACE Rust Preventing Characteristics Bath
Specifications
Conforms to the specifications of:
NACE TM-01-72; ASTM D665*, D6158, D3603*;
IP 135; ISO 7120; DIN 51585; FTM 791-4011; NF T 60-151
Testing Capacity: Six (6) 400mL sample beakers
Maximum Temperature: 104°C (220°F)
Temperature Control Stability: ±0.5°C (±1°F)
Heater Range: 0-1500W
Drive Motor: explosion proof ball bearing type
Bath Medium: 11 gal (41.6L) white technical oil
Electrical Requirements:
115V 60Hz, Single Phase,13.0A
220-240V 50Hz, Single Phase, 6.8A
220-240V 60Hz, Single Phase, 6.8A
*To order this equipment for ASTM and equivalent test methods,
please turn to page 128.
Ordering Information
Catalog No.
Rust Preventing Characteristics Oil Bath
K30160NACE Rust Preventing Characteristics
Oil Bath, 115V 60Hz
K30165NACE Rust Preventing Characteristics
Oil Bath, 220-240V 50Hz
K30166NACE Rust Preventing Characteristics
Oil Bath, 220-240V 60Hz
Order Qty
1
Accessories
332-002-007
250-000-09F
Included Accessories
Steel Test Specimens (6)
Type 2 Plastic Specimen Holders (6)
Plastic Beaker Covers (6)
250-000-09C
Dimensions lxwxh,in.(cm)
K30130
323⁄4x141⁄4x27 (83x36x69)
Net Weight: 79 lbs (35.8kg)
K30150
Shipping Information
Shipping Weight: 150 lbs (68.0kg)
Dimensions: 16.2 Cu. ft.
380-100-001
This equipment has been modified for safe operation when testing volatile
petroleum products in accordance with NACE Standard Test Method TM-01-72.
Test Beaker, 400mL, for NACE TM-01-72
ASTM 9F Thermometer
Range: 20 to 230°F
ASTM 9C Thermometer
Range: –5 to +110°C
Chuck for polishing test specimens
Includes locknut and shaft for mounting
on accessory drive motor
Drive Motor
Drives K30130 Chuck. Mounted on base.
115V 60Hz
Silicone Carbide Cloth, 100 grit
For preliminary grinding and final polishing
of test specimens. Pack of 50
Test Specimens
K30110
Steel Test Specimens for ASTM D665/
NACE TM-01-72. Machined to ASTM/NACE
specifications. Without holder
K30100
Test Specimen with Type 2 PMMA Holder
for ASTM D665/NACE TM-01-72
K30101
Test Specimen with Type 2 PTFE Holder
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
≥
Software compatible, inquire
with Koehler Customer Service.
98
6
7
1
1
1
0-96-106_5b_Fuel_Layout 1 10/24/12 11:14 AM Page 99
Silver Corrosion of Aviation Turbine Fuels
Test Method
Tests the corrosiveness of aviation turbine fuels towards silver. A polished
silver strip is immersed in a fuel sample at elevated temperature. After a
specified test period, the strip is removed from the sample, washed and
evaluated for corrosion.
Water Bath for Silver Corrosion
• Conforms to IP 227 specifications
• Six sample capability
Fully insulated, thermostatically controlled water bath with constant water
level device. Use together with K25370 Bath Conversion Kit to immerse
six 350mL test tubes for silver strip corrosion tests. Stainless steel inner
wall and powder coated steel outer wall construction.
Ordering Information
Catalog No.
K25310
K25319
K25370
Order Qty
Water Bath,
115V 60Hz
Water Bath,
220-240V 50/60Hz
Bath Conversion Kit for IP 227
1
1
Accessories
K25360
K25280
K25282
250-000-12C
K25000
380-240-001
380-150-001
380-150-000
Glassware Set for IP 227
Includes cold-finger condenser, glass cradle
and 350mL test tube
Silver Test Strip
Conforming to IP 227 specifications
ASTM D3241-IP 323 Color Standard
ASTM 12C Thermometer
Range: –20 to +102°C
Polishing Vise
Holds silver strip firmly in place without
marring the edges. Stainless steel,
mounted on a composition base
Silicone Carbide Paper, 240-grit
For final polishing of strips prior to testing.
Pack of 50 sheets
Silicone Carbide Paper, 150-grit
For polishing strips prior to testing.
Pack of 50 sheets
Silicone Carbide Grain, 150-grit
For polishing ends and sides of strips prior
to testing. 1 lb package
6
K25310 Constant Temperature Bath
6
Specifications
1
Conforms to the specifications of:
IP 227; ASTM D130, D4814, D6074, D6158; FSPT DT-28-65; IP 154;
ISO 2160; DIN 51759; FTM 791-5325
Testing Capacity: 6 samples for silver strip corrosion testing
Maximum Temperature: 221°F (105°C)
Temperature Control Stability: ±1°F (±0.5°C)
Heater Range: 0-750W
Bath Medium: 5 gal (18.9L) water
Electrical Requirements:
115V 60Hz, Single Phase, 7.5A
220-240V 50/60Hz, Single Phase, 4A
Temperature Control: Analog
1
1
1
1
Shipping Information
Shipping Weight: 29 Ibs (13.2kg)
Dimensions: 5.3 Cu. ft.
Additional Accessories for D4814
K25200
332-004-004
Copper Strip Corrosion Test Bomb
Test Tube
4
4
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
99
0-96-106_5b_Fuelaa3_Layout 1 11/29/12 6:45 PM Page 100
Cold Filter Plugging Point of Distillate Fuels
Test Method
Determines the low temperature flow characteristics of automotive diesel
fuels and gas oils, including samples with flow improving additives, by
measuring the temperature at which the sample ceases to flow through a
wire mesh filter under standard test conditions.
Cold Filter Plugging Point Test Equipment
• Conforms to ASTM D6371, IP 309 and DIN 51428 specifications
• Choice of mechanically refrigerated or dry ice cooled bath
Consists of Cold Filter Plugging Point Apparatus, Vacuum System and
Cooling Bath.
Cold Filter Plugging Point Apparatus–Includes borosilicate glass test jar with
graduation, brass jacket with plastic support ring, plastic stopper, plastic
insulating ring and spacer, pipette and brass filter unit with stainless steel
fine wire mesh screen.
Vacuum System–Connects to Cold Filter Plugging Point Apparatus to draw
sample through filter screen. Consists of U-tube Manometer (without
mercury), three-way stopcock, air vent tube, cork stopper with elbows, and
large glass bottle. Vacuum pump is not included.
Cooling Baths–Choice of mechanically refrigerated or dry-ice cooled
baths. Mechanically refrigerated model utilizes a cascade hermetic cooling
system to attain temperatures as low as –90°F (–68°C). Cold Filter
Plugging Point Apparatus inserts in composition top plate of bath.
Insulated stainless steel tank and polished stainless steel cabinet.
K45950 Cold Filter Plugging Point Bath
Ordering Information
Catalog No.
Cold Filter Plugging
K45900
Vacuum System
K45920
Cooling Bath
K45950
K45995
K45910
Point Apparatus
Cold Filter Plugging Point Apparatus
Vacuum System
Mechanically Refrigerated
Cold Filter Plugging Point Bath,
115V 60Hz
Mechanically Refrigerated
Cold Filter Plugging Point Bath,
220-240V 50Hz
Cooling Bath (Dry Ice Model)
Order Qty
1
Specifications
1
1
250-000-06C
ASTM 5C Thermometer
Range: –38 to +50°C
ASTM 6C Thermometer
Range: –80 to +20°C
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
≥
Software compatible, inquire
with Koehler Customer Service.
Conforms to the specifications of:
ASTM D6371; IP 309; DIN 51428
Electrical Requirements:
Mechanically Refrigerated Baths
115V 60Hz, Single Phase, 6A
220-240V 50Hz, Single Phase, 3A
Dimensions*in.(cm):
Accessories
250-000-05C
Dry-ice model includes insulated copper interior and steel exterior with
corrosion resistant polyurethane enamel finish. Composition top plate
suspends Cold Filter Plugging Point Apparatus in freezing mixture at the
required depth. Handles on exterior permit easy emptying of freezing
mixture. Supplied with thermometer holder.
Refrigerated Model (Ixwxh):
35x26x31 (89x66x78.75)
Net Weight: 259 lbs (117.75kg)
Dry-Ice Model (dia.xh):
12x12 (30x30)
*Cooling Bath
Shipping Information
Shipping Weight:
Refrigerated Model: 373 lbs (169.5kg)
Dry-Ice Model: 19 lbs (8.6kg)
Dimensions:
Refrigerated Model: 233⁄4 Cu. ft.
Dry-Ice Model: 3 Cu. ft.
100
0-96-106_5b_Fuelaa3_Layout 1 11/29/12 6:45 PM Page 101
Automated Cold Filter Plugging Point of Distillate Fuels
Test Method
Determines the highest temperature at which a given volume of diesel,
biodiesel or heating fuel fails to pass through a standardized wire mesh
filtration device in a specified time when cooled under specified conditions.
The Cold Filter Plugging Point (CFPP) of a fuel is suitable for estimating
the lowest temperature at which a fuel will give trouble-free flow in certain
fuel systems.
Automatic Cold Filter Plugging Point Analyzer with
Integrated Panel PC
•
•
•
•
Conforms to ASTM D6371 and related specifications
Stand alone system with Integrated Touch Screen Panel PC
Direct Cooling system eliminates the need for solvent cooling baths
One-stage cooling system provides temperatures as low as -45°C and
a two-stage cooling system down to -80°C
• Option of internal or external vacuum generation system
The cold filter plugging point detection system provides automated sample
testing with the accuracy and repeatability in accordance with ASTM D6371
and related international test methods. The sample is cooled according to the
pre-selected temperature profile. A 20 mBar vacuum is applied to the sample
at specific intervals across a 45 micron mesh filter into the aspiration glass cell
assembly. If it takes more than 60 seconds for the sample to reach the upper
barrier detector or more than 60 seconds to return below the detector upon
release, then the test is complete and the cold filter plugging point has been
reached.
Integrated Panel PC and Software Package–The Automated Cold Filter
Plugging Point Analyzer is a complete standalone system featuring an
integrated panel PC with an advanced software package. The 6.4” TFT/LCD
touch screen display has a resolution of 640x480 with a 262K color scheme.
All analytical parameters are graphed and displayed in real time as well as
recorded in Microsoft® Excel compatible file format. The software monitors the
operation and performance of all the analyzer components for proper data
measurement, including the solenoid valves, cooling system, pressure
sensors, and the Platinum resistance PT100 Class A temperature probe.
Cooling System–For various user applications, the automated cold filter plugging
point system is available with either one-stage cooling for temperatures as low as
-45°C or two-stage cooling for temperatures as low as -80°C. The direct cooling
system features integrated gas CFC free motors compressors thus eliminating the
need for a solvent cooling bath. The direct system is capable of rapid cooling,
approaching -80°C bath temperatures in approximately 15 minutes, and utilizes
less electricity than standard cooling systems. The rapid cooling feature combined
with a consistent cooling profile system provides repeatable results with high test
reproducibility.
KLA-4-TS Automatic CFPP Analyzer with Integrated Touch Screen PC
Specifications
Conforms to the specifications of: ASTM D6371; IP 309, 419; EN 116
Temperature Range: One-Stage: +60 to -45°C Two-Stage: +60 to -80°C
Resolution: 0.06°C
Accuracy: ±0.1°C
Repeatability / Reproducibility: as per standard test methods or better
Data Storage: > 60,000 analyses
Electrical Requirements: 115V ± 15% / 60Hz 220V ± 15% / 50 to 60Hz
Dimensions WxDxH,in.(cm)
26 x 233⁄4x 311⁄2(66x60x80)
Net Weight: 176.5 lbs (80kg)
Included Accessories
Calibrated Aspiration Pipette complete with Filter Kit for CFPP
Cord Cable without plug
Calibrated Test Jar
User Manual
Connection Tube for Vacuum System Operating Software Spacer
Safety Features
• Audible alarm and displayed messages (at the end of the analysis and
in case of errors and/or malfunctions)
• Pressure controller for 1st and 2nd stage motor compressor
• Thermostat for 2nd stage activation
• Thermo-switch for each cooling / heating jacket
• Motor compressors equipped with internal overload devices
Vacuum System–The automated cold filter plugging point analyzer can be
configured with either an internal or external vacuum generator. The internal
vacuum generator provides a smaller footprint for the complete CFPP system
and consists of a 350 mBar micro-pump and an electronic pressure/vacuum
regulator composed of a proportional valve, pressure/vacuum control sensor,
regulator for reference vacuum generation at 20 mBar and a vacuum
stabilizer. The external vacuum generator includes a vacuum pump, two glass
bottles and a glass cork with a U-tube, funnel and manual flow regulating valve.
Multiple Configuration System–These automated sample cooling and
physical property measurement systems can be configured with one, two,
three, four and six test positions with one of five possible analytical heads at
each position: cloud point, pour point, cloud & pour point, cold filter plugging
point and freezing point. Standard and customized multiple configuration
systems are readily available.
101
Ordering Information
Catalog No.
KLA-4-TS
Automatic Cold Filter Plugging Point Analyzer
with Touch Screen, (One-stage)
KLA-4-TS/2
Automatic Cold Filter Plugging Point Analyzer
with Touch Screen, (Two-stage)
KLA-4-IVPS
Internal Vacuum System for Cold Filter
Plugging Point Analyzer
KLA-4-VPS(115)
External Vacuum System for Cold Filter
Plugging Point, 115V
KLA-4-VPS(220)
External Vacuum System for Cold Filter
Plugging Point, 220V
Please specify voltage requirements when ordering.
Accessories
KLA-PT100-CAL
KLA-DB-KIT
Calibration Decade Box - PT100 Simulator
Set of Connectors and Cables
Extended Cooling Range down to -100˚C Available Upon Request.
0-96-106_5b_Fuel_Layout 1 10/24/12 11:14 AM Page 102
Octane Analyzer For Unleaded Gasolines
Test Method
Determines the Pump Octane Number (AKI), Research Octane Number
(RON), and Motor Octane Number (MON) of unleaded gasoline, ethanol
blended gasoline, leaded gasoline and Cetane Number for diesel fuels.
Portable Octane Analyzer
• Test results equivalent to ASTM D2699 and D2700 test methods
• Measures all grades of unleaded gasoline and ethanol blended gasoline
• Test results equivalent to ASTM D613 for Cetane Number of diesel fuels
(Optional with K88612)
• Displays results in 20 seconds
• Directly measures octane number for {(R+M)}/2, RON and MON
• Optional feature for cetane number determination of diesel fuels
• Includes RS-232 output, built-in printer and LCD display
• Results traceable to official knock engine laboratory
• GPS model available for use with GPS locator accessory
Measures octane number via near-infrared (NIR) transmission spectroscopy
utilizing 14 near-infrared emitting diodes with narrow bandpass filters, a silicon
detector system, and a fully integrated microprocessor. Simple octane number
determination requires three easy steps: sampling a background signal,
acquiring two absorption spectra of the gas sample, and then acquiring a second
background signal. Analyzer is pre-calibrated for unleaded gasoline and
ethanol-blended fuels, and can be calibrated for up to eight additional fuel types.
The analyzer is small, lightweight, and operates on "AA" batteries or AC. Before
each reading, the unit standardizes itself to assure accuracy. The octane number
is printed with time and date on the built-in printer. All data can be downloaded
via the RS232 port to an external computer.
K88600 Portable Octane Analyzer
Dimensions wxdxh,in.(cm)
Shipping Information
131⁄2x41⁄2x21⁄2 (34x111⁄2x61⁄4)
Net Weight: 12 lbs (5.5kg)
23x17x81⁄2 (581⁄2x431⁄4x22)
Shipping weight: 25 lbs (11.5kg)
Specifications
Ordering Information
Accuracy and repeatability equivalent to ASTM approved CFR engines test
methods (ASTM D2699, D2700)
Sample Holder: Sealed, cubical glass container (75mm optical path length)
Sample Volume: 8 Ounces (approx. 225 mL)
Operating Temperature Range: 7°C - 38°C
Pre-calibrated for unleaded & ethanol-blended gasoline
(Analyzer can be calibrated for up to 8 additional fuel types.)
Battery operated (6 AA batteries)
Electrical Requirements:
115/240V 50/60Hz
Catalog No.
K88600
K88600-GPS
Accessories
Safety Features
Out of Temperature Range Warning: Analyzer displays Out of Range Warning
Message when instrument in being used outside of its standard operating
temperature range. Either above 38°C or below 7°C.
Out of Calibration Range Warning: Analyzer displays “Too High” or “Too
Low” message when measurement reading is out of the instruments
calibration range.
Bad Curve Warning: Analyzer warns user when light protective lid is not on
during testing. External light source will greatly disrupt results.
K88601
K88603
K88604
K88605
K88606
K88607
K88608
K88609
K88610
Printer Paper, 10 Rolls
Sample Holder (additional)
Sample Holder (Box of 12)
Light Shield
RS232 Cable
Aluminum Sample Carrying Case w/12 Sample Holders
Sample Holder Lids, Quantity 12
Sample Holder Labels, Quantity 12
25 Sample Memory
K88612
K88602
K88613
Cetane Number Calibration
Additional Fuel Calibration
GPS Locator (for K88600-GPS model only)
Optional Features
Included Accessories
Calibration Software
Aluminum Carrying Case
Sample Holder (3)
AA Battery (6)
Portable Octane Analyzer
Portable Octane Analyzer GPS Model
Requires GPS Locator Feature (K88613)
RS232 Cable
Printer Paper Roll (5)
Light Cover
Sample Holder Label (6)
102
0-96-106_5b_Fuelaa_Layout 1 11/5/12 11:42 AM Page 103
Density/Relative Density of Light Hydrocarbons
by Pressure Thermohydrometer
Test Method
Density and relative density measurements of light hydrocarbons, including
LPG, are used for transportation, storage and regulatory purposes. The
measurement is made by floating a thermohydrometer in a sample that has
been introduced into a pressure cylinder.
Pressure Hydrometer Cylinder
• Conforms to ASTM D1657 and related specifications
• Built-in safety relief valve
Transparent plastic cylinder mounted between machined aluminum end plates
and surrounded by stainless steel safety guard. Use together with ASTM 310H
Thermohydrometer to determine density or relative density of LPG and light
hydrocarbons. Equipped with inlet, outlet and vapor vent valves for admitting
sample and purging cylinder. End plates have positive sealing buna-N O-rings
and are joined by sturdy steel support rods. Top plate detaches easily without
tools for insertion or removal of thermohydrometer. Safety relief valve prevents
unsafe pressure build-up inside cylinder. Mounted on a finished steel base.
Specifications
Dimensions dia.xh,in.(cm)
Conforms to the specifications of:
ASTM D1657; GPA 2140;
IP 235; IS0 3993; NF M 41-008
Safety relief valve: 200psi (1.4MPa)
81⁄4x233⁄4 (21x60)
Net Weight: 5 lbs (2.3kg)
Ordering Information
Catalog No.
K26150
Pressure Hydrometer Cylinder
Accessories
251-000-001
251-000-004
ASTM 101H Thermohydrometer
Nominal Relative Density Range: 0.500 to 0.650
Standard Temperature, °F: 60/60
Temperature Range, °F: 30 to 90
ASTM 310H Thermohydrometer
Density Range kg/m3: 500-650
Standard Temperature, °C: 15
Temperature Range, °C: 0 to 35
K26150 Pressure Hydrometer Cylinder
Constant Temperature Water Bath
• Conforms to ASTM D1657 and related specifications
• Mechanically refrigerated for convenient sub-ambient temperature operation
Immerses two Pressure Hydrometer Cylinders at 60°F (15°C) for density and
relative density determinations of LPG and other light hydrocarbons.
Mechanically refrigerated cooling system maintains sub-ambient temperature.
Thermistor activated solid state temperature controller and 750W copper
immersion heater maintain bath temperature with ±0.5°F (±0.2°C) stability. A
1
⁄20 hp ball bearing stirrer circulates the bath medium to assure temperature
uniformity. Stainless steel tank is fiberglass insulated. Equipped with overflow
standpipe/drain. Steel exterior has a durable polyurethane enamel finish.
Dimensions lxwxh,in.(cm)
Shipping Information
Bath interior: 12x18x22(30x46x56)
Overall: 18x20x49 (46x51x124)
Net Weight: 158 lbs (71.7kg)
Shipping Weight: 186 lbs (84.4kg)
Dimensions: 15.4 Cu. ft.
Ordering Information
Catalog No.
K25900
K25990
K25995
Constant Temperature Water Bath, 115V 60Hz
Constant Temperature Water Bath, 220-240V 60Hz
Constant Temperature Water Bath, 220-240V 50Hz
250-000-12F
250-000-12C
ASTM 12F Thermometer. Range –5 to +215°F
ASTM 12C Thermometer. Range –20 to +102°C
Specifications
Conforms to the specifications of: ASTM D1657; IP 235; ISO 3993
Controller Sensitivity: ±0.5°F (±0.2°C)
Capacity: two (2) K26150 cylinders
Electrical Requirements:
115V 60Hz, Single Phase, 12.5A
220-240V 50 or 60Hz, Single Phase, 6.4A
Accessories
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
103
0-96-106_5b_Fuelaa3_Layout 1 11/29/12 6:45 PM Page 104
Hydrocarbon Types in Liquid Petroleum Products
Test Method
Determines saturates, olefins and aromatics in petroleum fractions that
distill below 315˚C.
Fluorescent Indicator Absorption Apparatus
•
•
•
•
•
Conforms to ASTM D1319 specifications
Quick connections for columns for faster set-up and analysis
Integrated vibration system for dry silica gel packing
Handheld UV Lamp
Two, four, or six column models available
A complete system for conducting FIA analyses of a single or up to six samples
simultaneously. Each system is complete with an upper multi-position air
pressure manifold with independently-operated gauges, pressure regulators
and ball O-ring joints allowing for individual pressure control at each column.
Each pressure regulator may be set at any point from 0-15 psi and will
maintain the set pressure regardless of changes in back pressure. An integral
pressure gauge on each station continuously registers the active pressure on
each column. The ball O-ring connection system connects the pressure
regulators to the upper columns, and the proper seal is achieved by applying
moderate clamping pressure of stainless steel clamps without utilizing any
grease. Convenient O-ring compression type fittings simplify the connection of
the analyzer tubes (3mm OD x 1200mm) to the upper columns. The internal
geometry of the fittings is optimized for transition between tubing diameters,
and a simple twist of the connection fitting releases the analyzer tube. O-ring
compression type fittings are also used to cap the end of each analyzer tube
with the column support tips. The tips contain an internal porous polyethylene
disc in order to support the silica gel packing in each analyzer tube. An
integrated electric vibration system is mounted to the upper chassis so that the
columns can be vibrated to facilitate the dry gel packing procedure, and features
an on/off and amplitude selector switch. The complete unit also includes a
1mL syringe with 4” needle, two gel bottles for pouring silica gel, extra O-rings,
stainless steel ball-and-socket joint clamps, and two mounting brackets with
screws for stabilizing chassis.
Ordering Information
Catalog No.
K41502
Fluorescent Indicator Absorption Apparatus,
Two-Position, 115V 60Hz
K41592
Fluorescent Indicator Absorption Apparatus,
Two-Position, 230V 50/60Hz
K41504
Fluorescent Indicator Absorption Apparatus,
Four-Position, 115V 60Hz
K41594
Fluorescent Indicator Absorption Apparatus,
Four-Position, 230V 50/60Hz
K41506
Fluorescent Indicator Absorption Apparatus,
Six-Position, 115V 60Hz
K41596
Fluorescent Indicator Absorption Apparatus,
Six-Position, 230V 50/60Hz
K41506 Fluorescent Indicator Absorption Apparatus
Specifications
Conforms to the specifications of:
ASTM D1319; IP 156; NF M 07-024
Electrical Requirements:
115V 60Hz
220-240V 50/60Hz
Included Accessories
Syringe, 1mL
Bottles (2)
O-Rings
Accessories
Ball-and-Socket Joint Clamps
Mounting Brackets (2)
Integrated Electric Vibration
Handheld UV Lamp
K41500-4
K41500-5
K41579
K41580
Dimensions lxwxh,in. (cm)
8x26x82 (20x66x208)
Net Weight: 100 lbs (45.5kg)
Shipping Information
Shipping Weight: 121 lbs (55kg)
Dimensions: 12 Cu. ft.
104
Silica Gel, 500 Gram Amber Bottle
Silica Gel, Dyed, 40 Gram Bottle
Standup UV Lamp, 115V 60Hz
Standup UV Lamp, 230V 50/60Hz
0-96-106_5b_Fuel_Layout 1 10/24/12 11:14 AM Page 105
Volatility and Residues in Liquefied Petroleum (LP) Gases
Volatility of Liquefied Petroleum (LP) Gases
Residues in Liquefied Petroleum (LP) Gases
Test Method
Ordering Information
Catalog No.
K48100
Precooling Apparatus
332-010-001
339-000-001
337-000-002
338-000-001
362-001-001
K481-0-5
250-000-99F
250-000-99C
250-000-05F
250-000-05C
250-000-57F
250-000-57C
Weathering Tube, 100mL
Stand, for weathering tube
Clamp, for weathering tube
Clamp Holder
Syringe, 1mL (ASTM D2158)
Needle, 8"/203mm (ASTM D2158)
ASTM 99F Thermometer, Range: –55 to +41°F
ASTM 99C Thermometer, Range: -50 to +5°C
ASTM 5F Thermometer, Range: –36 to +120°F
ASTM 5C Thermometer, Range: –38 to +50°C
ASTM 57F Thermometer, Range: –4 to +122°F
ASTM 57C Thermometer, Range: –20 to +50°C
Accessories
The volatility of liquefied petroleum (LP) gases is determined by allowing
a precooled sample to weather under specified conditions and observing
the temperature when 95% has evaporated. Residues in LP gases are
determined by weathering of a precooled sample and determination of the
volume remaining at 100°F (37.8°C).
Precooling Apparatus
• Conforms to ASTM and GPA specifications
Consists of brass cooling vessel with built-in 20 ft. (6m) copper cooling coil.
Includes compression fittings and 1⁄8" needle valve at the downstream end.
Specifications
Conforms to the specifications of: ASTM D1837; D2158; GPA 2140; ISO 13757
Dimensions: *dia.xh,in.(cm) 3x113⁄4 (7.6x29.9)
*Cooling Vessel
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Filterability of Diesel Fuels by Low-Temperature Flow Test
Test Method
Determines the filterability of Diesel fuels and Biodiesel blend fuels in
some automotive equipment at low temperatures. The Low Temperature
Flow Test results are indicative of the low temperature flow performance of
the test fuel in some diesel vehicles. The test method is especially useful
for the evaluation of fuels containing flow improver additives in a range of
+10°C to -30°C.
Automatic Low Temperature Filterability Test Analyzer
(LTFT)
Up to (6) 300 ml test vessels are cooled at a specified rate of 1°C/h, and at
every °C of cooling, a vacuum of 20 kPa is applied to a filter assembly
immersed in the first sample. If the sample recovered in a graduated receiver
vessel reaches the 180 ml in 60 sec., the analysis continues to the further 1°C
test temperature (passed). When the sample doesn't reach the 180 ml within
the 60 sec., the test is failed. The temperature of the last passing result test has
to be recorded as minimum LTFT pass temperature.
The instrument is a six place floor model, equipped with a built in cooling
system with a single stage CFC free motor compressor for temperatures as
low as -45°C. Integrated Vacuum System consisting of a 350 kPa micropump,
vacuum stabilizer and electronic control for vacuum regulation of 20 kPa. Fully
automatic, controlled by an integrated panel pc with touch screen and a large
display. All the parameters and the current status of the analysis are shown in
real time.
KLA-7 LTFT
Specifications
Ordering Information
Conforms to the Specifications of: ASTM D4539
Temperature Range: +80°C to -80°C
Resolution: 0.06°C
Accuracy: ±0.1°C
Repeatability / Reproducibility: Meets or exceeds ASTM specifications
Storage Capacity: Up to 60,000 analyses
Interface: USB Port (2)
Electrical Requirements:
115V ±15%, 60Hz
220V ±15%, 50/60Hz
Dimensions: wxdxh,in.(cm)
381⁄2 x 231⁄2 x 511⁄4 (98x60x130)
Net Weight: 176.5 lbs (80kg)
Catalog No.
KLA-7
KLA-7 (220)
Automatic Low Temperature Filterability Test
Analyzer (LTFT), 115V 60Hz
Automatic Low Temperature Filterability Test
Analyzer (LTFT), 220V 50/60Hz
Accessories
KLA-PT100-CAL
KLA-DB-KIT
105
Calibration Box and Cables
Kit of Connectors and Cables for Cold range
0-96-106_5b_Fuel_Layout 1 10/24/12 11:14 AM Page 106
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Oxidation Stability of Gasoline
(Induction Period Method) .................................................Pages 80-84
ASTM D525; IP 40; DIN 51780; FTM 791-3352
Corrosion Resistant Steel Forceps
Oven
Distilled Water
Chromic Acid or equivalent detergent cleaning solution
Toluene
Acetone
Oxygen
Oxidation Stability of Aviation Fuels
(Potential Residue Method)...............................................Pages 80-84
ASTM D873; IP 138; DIN 51799; FTM 791-3354
Corrosion Resistant Steel Forceps
Drying Oven
Filtering Crucible
Oxygen
Toluene
Distilled Water
Acetone
Existent Gum in Fuels by Jet Evaporation..........................Page 86-87
ASTM D381; IP 131; ISO 6246; DIN 51784; FTM 791-3302
Analytical Balance
Desiccator
Filtering Funnel, Sintered Glass
n-Heptane
Air Supply (for Air-Intake Method)
Toluene
Acetone
Graduated Cylinder
Chromic Acid or equivalent detergent cleaning solution
Distilled Water
Oven
Copper Strip Corrosion by
Liquefied Petroleum (LP) Gases ..............................................Page 89
ASTM D1838; GPA 2140; ISO 6251
Acetone
2,2,4-Trimethylpentane
Cotton Wool
Copper Corrosion From Petroleum Products
by the Copper Strip Tarnish Test........................................Pages 90-91
ASTM D130; FSPT DT-28-65; IP 154; ISO 2160; DIN 51759; FTM 791-5325
Filter Paper
Cotton Wool
Isooctane or volatile, sulfur-free hydrocarbon solvent
Stainless Steel Forceps
Stoddard Solvent
Kerosene
Vapor Pressure of Petroleum Products (Reid Method) ....Pages 92-94
ASTM D323, D1267; GPA 2140; IP 69, 161; ISO 3007, 4256; DIN 51616,
51754; FTM 791-1201
Dead-Weight Tester
Petroleum Naphta
Acetone
Air Supply
Wax Appearance Point of Distillate Fuels...............................Page 94
ASTM D3117
Isopropanol
Solid Carbon Dioxide
Liquid Nitrogen
Freezing Point of Aviation Fuels..........................................Page 96-97
ASTM D2386; IP 16; ISO 3013; DIN 51421; FTM 791-1411
Ethanol
Methanol
Solid Carbon Dioxide
Liquid Nitrogen
Acetone
Isopropanol
Silver Corrosion by Aviation Turbine Fuels .............................Page 99
IP227; ASTM D130; FSPT DT-28-65; IP 154; ISO 2160,
DIN 51759; FTM 791-5325
2,2,4-Trimethylpentane
Ashless Filter Paper
Stainless Steel Forceps
Cotton Wool
Antirust Properties of Petroleum Products
Pipeline Cargoes........................................................................Page 98
NACE TM-0172
Naphtha or Acetone
Chromic Acid
Cold Filter Plugging Point of Distillate Fuels ...............Pages 100-101
ASTM D6371; IP 309; DIN 51428
Heptane
Lintless Filter Paper
Vacuum Pump
106
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 107
Lubricating Oils
Test Methods
Page
Test Methods
Page
Foaming Characteristics of Lubricating Oils ASTM D892, D6082;
IP 146; DIN 51566; FTM 791-3211, 791-3213 ............................108-110
Oxidation Stability of Inhibited Mineral Insulating Oils IP 335 ........126
Water Separability of Petroleum Oils and Synthetic Fluids
ASTM D1401, D6074, D6158; ISO 6614; DIN 51599; FTM 791-3201..111
Thermal Oxidation Stability of Automotive, Gear Lubricants
ASTM D5704; STP 512A L-60 Performance Test
(formerly CRC L-60 Test); FTM 791 B Method 2504 95 ....................127
Demulsibility Characteristics of Lubricating Oils
ASTM D2711..........................................................................................112
Air Release Properties of Petroleum Oils
ASTM D3427; IP 313; DIN 51381 ........................................................113
Oxidation Stability of Steam Turbine Oils by Rotating Bomb
ASTM D2272..................................................................................114-118
Oxidation Stability of Inhibited Mineral Insulating Oil
by Rotating Bomb ASTM D2112; IP 229 ....................................114-118
Oxidation Stability of Gasoline Automotive Engine Oils by
Thin-Film Oxidation Uptake (TFOUT) ASTM D4742 ..................114-118
Oxidation Characteristics of Inhibited Mineral Oils
ASTM D943, D2240, D4636, D5968, D6158; DIN 51586,
51587, 51394; FTM 791-5307, 791-5308 ....................................119-122
Determination of the Sludging Tendencies of Inhibited Mineral Oils
ASTM D4310..................................................................................119-122
Oxidation Test For Lubricating Oil IP 48 ............................................126
Rust Preventing Characteristics of Inhibited Mineral Oil in the
Presence of Water (Standard and Horizontal Disc Methods)
ASTM D665, D3603, D6158; NACE TM-01-72; IP 135; ISO 7120;
DIN 51355, DIN 51585; FTM 791-4011, 791-5315 ....................128-129
Stability of Lubricating Oils (Work Factor) FTM 791-3451.4 ..........130
Corrosion of Lead by Lubricating Oils FTM 791-5321 ......................130
Copper Corrosion From Petroleum Products
ASTM D130, D6074, D6158; IP 154 ....................................................131
Bearing Compatibility of Turbine Oils FTM 791-3452 ......................131
Pour Point of Petroleum Oils
ASTM D97; IP 15; ISO 3016; DIN 51597; FTM 791-201 ............132-133
Cloud Point of Petroleum Oils
ASTM D2500; IP 219; ISO 3015; DIN 51597 ..............................132-133
Oxidation Stability of Distillate Fuel Oil (Accelerated Method)
ASTM D2274..................................................................................119-122
Dielectric Breakdown Voltage of Insulating Oils
ASTM D877, D1816; IP 295; FTM 791-5702;
NF C 27-221; IEC 156; VDE 0370......................................................134
Oxidation Characteristics of Extreme Pressure Lubricating Oils
ASTM D2893..................................................................................119-122
Coking Tendency of Oil FTM 791-3462 ..............................................135
Oxidation Stability of Mineral Insulating Oils ASTM D2440 ............123
Corrosiveness and Oxidation Stability of Hydraulic Oils, Aircraft
Turbine Engine Lubricants, and Other Highly Refined Oils
ASTM D4636, D5968; FTM 791-5307, 791-5308; IHC BT-10;
DIN 51394 ......................................................................................124-125
Oxidation Stability of Inhibited Mineral Turbine Oils
IP 280 ....................................................................................................126
Oxidation Stability of Straight Mineral Oil IP 306 ............................126
Evaporation Loss of Lubricating Oils (Noack Test)
ASTM D5800; DIN 51851; IP 421 ........................................................136
For information on additional test methods for Lubricating Oils:
–Evaporation Loss of Lubricating Greases and Oils
–please refer to pages 148-149
–Estimating Apparent Vapor Pressures and Molecular Weights of Lubricating Oils
–please refer to pages 92-94
–Please refer to the Viscosity, Flash Point and General Tests Sections
–Additional test methods are available upon request
–please call or write for information.
Oxidation Stability of Mineral Insulating Oil IP 307 ........................126
www.koehlerinstrument.com
0-107-123_6a_LOilsAA_Layout 1 11/29/12 6:57 PM Page 108
Foaming Characteristics of Lubricating Oils
Test Method
Foaming of lubricating oils in applications involving turbulence, high speed
gearing or high volume pumping can cause inadequate lubrication,
cavitation, overflow and premature oxidation. The sample is blown with a
controlled volume of air at different specified temperatures, including a
newer high temperature test at 150°C. The resultant foam is measured at
the end of each aeration period and at different intervals afterward. In the
high temperature test, the amount of time required for the foam to collapse
to “0” after the aeration period is also measured.
Foaming Characteristics Test Baths
•
•
•
•
Dual-twin models for standard foaming characteristics tests
High temperature liquid bath for ‘Sequence IV’ tests
Automatic time sequence models for both tests
Custom configurations for specialized applications
Dual Twin Foaming Characteristics Test Apparatus–Performs two
tests at 75°F (24°C) and two tests at 200°F (93.5°C). Consists of two 12x18"
(30.5x45.7cm) constant temperature baths with 1000mL test cylinders, certified
diffusers, air delivery tubes, and flowmeters (94mL/min.) for each sample.
Baths are equipped with microprocessor temperature controls, copper
immersion heaters and 1⁄20hp circulation stirrers to maintain temperature
uniformity of ±1°F (±0.5°C). Microprocessor PID control provides quick
temperature stabilization without overshoot and the bath is protected by an
overtemperature control circuit that interrupts power should bath temperature
exceed a programmed cut-off point. Dual LED displays provide actual and
setpoint temperature values in °C/°F format. Test cylinders are held securely in
place by quick-locking cams in the bath cover assembly. A separate stainless
steel support rack is provided to hold the test cylinders after removal from the
bath. Cold bath (24°C) has built-in coils for circulating exit air from the high
temperature test cylinders prior to passing to a volume meter, and a separate
coil for circulating cooling water or refrigerant when the ambient temperature
exceeds the test temperature. Supplied with rubber stoppers and glass air
outlet tubes for each cylinder. Bath controls are enclosed in a finished steel
base with chemical resistant polyurethane enamel finish. Communications
software as seen on page 110 (RS232, etc.), ramp-to-set and other
enhanced features are available as extra cost options. Contact your Koehler
representative for information.
FTM 791-3213 Aircraft Lubricants Test–Employs more severe
conditions, smaller sample, increased air flow, and longer aeration period to
test the foaming characteristics of aircraft-turbine lubricants. All models are
available on special order for FTM 791-3213 testing. Please call or write for
specifications and ordering information.
Specifications
Included Accessories
Conforms to the specifications of:
ASTM D892; IP 146; DIN 51566;
FTM 791-3211, 791-3213*; NF T
60-129
Temperature Control:
Digital Setpoint and Displays °C/°F
switchable
Built-in Overtemperature Cut-off
Protection
Test Cylinders, 1000mL (4)
Diffuser Stones, calibrated and
certified (4)
Air Delivery Tube Assemblies (4)
Air Outlet Tubes (4)
Rubber Stoppers (4)
Bath Jars (2)
Support Rack (1)
Acrylic Safety Shield, 18"
High Temperature ‘Sequence IV’ Liquid Foam Test Bath–For two tests
at 150°C with a flow rate of 200mL/min. in accordance with ASTM D6082
specifications. Consists of a constant temperature bath with 1000mL test
cylinders, certified diffusers, air delivery tubes and flowmeters.
Microprocessor PID control provides quick temperature stabilization without
overshoot and the bath is protected by an overtemperature control circuit that
interrupts power should bath temperature exceed a programmed cut-off point.
Dual LED displays provide actual and setpoint temperature values in °C/°F
format. Quick response copper immersion heaters provide efficient high
temperature operation, and a stirrer unit provides complete circulation for
temperature uniformity of better than ±1°F (±0.5°C). Locking cams hold the
test cylinders in a vertical position, and a separate rack is provided to hold the
cylinders after removal from the bath. For operator safety, an acrylic heat shield
surrounds the Borosilicate Glass bath jar. Communications software (RS232,
etc.), ramp-to-set and other enhanced features are available as extra cost
options. Contact your Koehler representative for information.
Specifications
Conforms to the specifications of: ASTM D6082
Temperature Control:
Digital Setpoint and Displays °C/°F switchable
Built-in Overtemperature Cut-off Protection
Included Accessories
*Requires modifications to standard equipment.
This equipment is available with a digital-indicating mass flow controller in place of the
standard flowmeter. Please call or write for specifications and/or ordering information.
Digital Flowmeter option
is available for this unit.
K43041
Sequence IV
Liquid Foaming
Characteristics
Apparatus
Test Cylinders, 1000mL (2)
Diffuser Stones, calibrated and certified (2)
Air Delivery Tube Assemblies (2)
Air Outlet Tube (2)
≥
Software compatible, inquire
with Koehler Customer Service.
108
Bath Jar (1)
Support Rack (1)
Rubber Stoppers (2)
Acrylic Safety Shield, 18"
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 109
Foaming Characteristics of Lubricating Oils
Ordering Information
Catalog
No.
K43002
Model
DualTwin
K43092
Automatic
Time
Sequence
K43003
K43093
Sequence
IV
Liquid
K43041
K43049
Electrical
Requirements
115V
60Hz
15.6A
220-240V
50/60Hz
8.1A
115V
60Hz
16A
220-240V
50/60Hz
8A
115V
60Hz
14A
Bath
Temperature
24°C
(75°F)
Air
Flow Rate
and
93.5°C
(200°F)
94mL/min
9 gal
(38.5L)
each
bath
(Operator
variable)
150°C
(302°F)
200mL/min
(Operator
variable)
220-240V
50/60Hz
7A
Bath
Capacity
9 gal
(38.5L)
Dimensions
lxwxh,in.(cm)
Shipping
Information
321⁄4x15x311⁄4
(82x38x79.4)
Net Weight:
108 lbs (49kg)
Shipping Wgt.
217 lbs
(98.4kg)
Dimensions
29.6 Cu. ft.
321⁄4x15x311⁄4
(82x38x79.4)
Net Weight:
118 lbs (53.5kg)
Shipping Wgt.
227 lbs
(103kg)
Dimensions:
33 Cu. ft.
163⁄4x15x311⁄4
(42.5x38x79.4)
Net Weight:
62 lbs (28.1kg)
Shipping Wgt.
89 lbs
(40.4kg)
Dimensions
16.3 Cu. ft.
D892 and D6082 Dual Twin Foaming Characteristics Test
Apparatus–For four tests in accordance with control ASTM D6082 and ASTM
D892 specifications. Dual liquid baths feature digital temperature control for
Sequences I through IV. Four flowmeters maintain the required flow rate of 94
and 200mL/min to the air diffusers. Requires the use of an external chiller to
perform the Sequence I and III tests at 24°C.
Specifications
Conforms to the specifications of:
ASTM D892, D6082; IP 146; DIN 51566; FTM 791-3211; NF T 60-129
Temperature Control:
Digital Setpoint and Displays °C/°F switchable
Built-in Overtemperature Cut-off Protection
Included Accessories
Test Cylinders, 1000mL (4)
Diffuser Stones, calibrated and certified (4)
Air Delivery Tube Assemblies (4)
Air Outlet Tubes (4)
Rubber Stoppers (4)
Bath Jars (2)
Support Rack (1)
Acrylic Safety Shield, 18"
Accessories and Additional Ordering Information
K43092 Dual-Twin Foaming Characteristics Apparatus
For a complete listing of accessories and information on ordering a complete
package for ASTM D892 and/or D6082 testing, please turn to page 110.
Ordering Information
Model
D892/D6082
Dual Twin
Catalog
No.
K43005
K43095
Digital Flowmeter option
is available for this unit.
Electrical
Requirements
115V
60Hz
15.6A
220-240V
50/60Hz
8.1A
Bath
Temperature
Left (Cold) Bath: Ambient to 93.5°C
(200°F) External Chiller required to
perform Sequence I and III at 24°C
Right (Hot) Bath: Ambient to 150°C
(302°F)
≥
Software compatible, inquire
with Koehler Customer Service.
109
Air
Flow Rate
Bath
Capacity
Dimensions
lxwxh,in.(cm)
Shipping
Information
94mL/min and
200mL/min
9 gal
(38.5L)
each
321⁄4x15x311⁄4
(82x38x79.4)
Net Weight:
108 lbs (49kg)
Shipping Wgt.
217 lbs
(98.4kg)
Dimensions:
29.6 Cu. ft.
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 110
Foaming Characteristics of Lubricating Oils
Accessories
Catalog No.
387-115-001 Air Pump, oil-less. Delivers 100% oil-free air. 115V 60Hz
387-230-001 Air Pump, oil-less. 220-240V 50/60Hz
K43026
Wet Test Gas Meter
For volume measurements of air leaving the test cylinders.
Note: One meter is required for each test cylinder.
Not required for the ‘Alternative Procedure’ - Section 9.1.
332-005-005 Drying Tower. 300mm
K43025
Diffuser Stone Test Apparatus
For maximum pore diameter and permeability tests on
diffuser stones. Consists of 90cm manometer, 500mL flask,
flowmeter, graduate, delivery tube assembly and control valve.
K33031
Refrigerated Recirculator
Use with foam test baths for 24°C tests (Sequence I and III).
Microprocessor based digital control and quiet running
compressor provide reliable operation and accurate control
within ±0.5°C. For complete specifications, please contact
Koehler Customer Service. 115V 60Hz, 8A
K33032
Refrigerated Recirculator, 220-240V 50Hz, 4A
250-000-12F ASTM 12F Thermometer. Range: –5 to +215°F
250-000-12C ASTM 12C Thermometer. Range: –20 to +102°C
250-000-41C ASTM 41C Thermometer. Range: 98 to 152°C
344-100-01C Certified Diffuser Stone. Calibrated and certified for
compliance with ASTM specifications for pore diameter
and permeability
344-100-001 Diffuser Stone, non-calibrated
344-005-001 Stainless Steel ‘Mott’ Diffuser
344-005-01C Stainless Steel ‘Mott’ Diffuser Certified
K43012
Test Cylinder
Replacement 1000mL cylinder. Includes retaining ring.
Advanced Communications Software Package for Data Management
Test apparatus for ASTM D892 Sequence I, II and III
Catalog No.
Order Qty
K43002
Dual Twin Foam Test Apparatus
1
(or K43003 Automatic Time Sequence Model)
387-115-001
Air Pump
1
K43025
Diffuser Stone Test Apparatus
1
250-000-12F
ASTM 12F Thermometer
2
(or 250-000-12C ASTM 12C Thermometer)
K43026
Wet Test Gas Meter
1
(not required for Alternative Procedure)
332-005-005
Drying Tower
1
Test apparatus for ASTM D6082 Sequence IV
Catalog No.
K43041
Sequence IV Foam Test Bath
K43025
Diffuser Stone Test Apparatus
K43026
Wet Test Gas Meter
332-005-005
Drying Tower
387-115-001
Air Pump
250-000-41C
ASTM 41C Thermometer
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
Order Qty
1
1
1
1
1
1
Test apparatus for ASTM D892 and D6082
Catalog No.
Order Qty
K43005
D892 and D6082 Dual Twin Foam Test
1
Apparatus
K43025
Diffuser Stone Test Apparatus
1
K43026
Wet Test Gas Meter
1
332-005-005
Drying Tower
1
387-115-001
Air Pump
1
250-000-12F
ASTM 12F Thermometer
2
(or 250-000-12C ASTM 12C Thermometer)
250-000-41C
ASTM 41C Thermometer
2
110
0-107-123_6a_LOilsAA_Layout 1 11/29/12 6:58 PM Page 111
Water Separability of Petroleum Oils and Synthetic Fluids
Test Method
The ability of a lubricating oil to separate from water and resist
emulsification is an important performance characteristic for applications
involving water contamination and turbulence. Water separability is
determined by stirring equal volumes of water and sample together at a
controlled temperature to form an emulsion and observing the time
required for separation of the emulsion to occur. This method is suitable for
petroleum oils and synthetic fluids.
Water Separability Tester
• Tests emulsion characteristics of lubricating oils
• Seven sample capacity
• Movable digital stirrer with microprocessor control incorporates advanced
features for flexibility and ease of operation
• Clear, illuminated heating bath provides excellent visibility
• Microprocessor temperature control with digital display and built-in
protection against overtemperature and low liquid level hazards
• Conforms to ASTM, ISO and related standards for water separability testing
• Optional sensor for direct measurement of sample temperature
• With built in drain for convenient draining of bath medium
Seven-sample Water Separability Tester provides full visibility and
microprocessor control of all functions for simplified, accurate testing of up to
seven samples at a time. Use for specification of new oils and monitoring of
in-service petroleum oils and synthetic fluids.
Seven position heating bath–A full visibility bath immerses seven 100mL
cylinders at the proper depth per ASTM and ISO specifications. Sample
cylinders are held securely in place by stainless steel supports inside the bath.
A microprocessor based heater controls bath operating controls bath fluid
temperature with greater than ±1˚C accuracy and stability throughout the
operating range of 25˚C to 84˚C. Large LED readouts display setpoint and
actual temperatures in Celsius or Fahrenheit scale at the operator’s option. For
most samples, ASTM/ISO sample temperatures of 54˚C and 82˚C are attained
within 10 minutes after placement of the test cylinders into the stabilized bath.
Clear polycarbonate tank has backlighting for excellent visibility when viewing
emulsion separations in the test cylinders. Cut-off circuits for low water level
and over-temperature conditions provide protection in the event of equipment
malfunction. Easy removal of top plate for filling or cleaning the bath.
Polycarbonate jar is encased in a Polyester-Epoxy finished steel housing with
a protective distortion-free viewing window and a solid foundation.
Microprocessor sample stirrer–To avoid sample movement, the sample stirrer
housing pivots to each test position in the bath and locks securely in place
at the required position in relation to the 100mL sample cylinder. The digital
stirrer offers complete flexibility for test duration and stirring speed at the push
of a button. Operating speed and count down time are prominently displayed
on a large backlit LCD panel. A wide operating range of 0-2000rpm permits
in-house customized testing with ±1rpm accuracy, and the operator may select
a stirring time of up to 99.99 minutes. At the end of the selected interval, the
stirrer automatically shuts off and alerts the operator with audible and visual
signals that the settling period has commenced. For added convenience, all test
parameters are stored in memory and repeated in subsequent tests until they
are changed by the operator. Engaging the stirrer mechanism is visible to the
operator and housed in a clear tube for added safety.
K39400 Water
Separability Tester
Specifications
Conforms to the specifications of: ASTM D1401, D6074, D6158; ISO 6614;
DIN 51599; FTM 791-3201; NF T 60-125
Stirrer Range: 0-2000rpm
Accuracy: ±1.0rpm
Drive: 1⁄10hp (75W), high torque
Bath Temperature Range: 25˚C to 84˚C
Control Stability: ±0.05˚C
Capacity: seven (7) 100mL graduated cylinders
Construction: Clear polycarbonate tank 10"x11.25"x9.5" (25.5x28x24cm)
Medium: Water or white technical oil
Medium Capacity: 15.15L (4 gal)
Electrical Requirements:
115V 60Hz, Single Phase, 12A
220-240V 50/60 Hz, Single Phase, 12A
Dimensions lxwxh, in.(cm)
Included Accessories
20.75x15.25x29.5
(52.7x38.75x 74.9)
Net Weight: 78 lbs (35.5kg)
Seven 100mL Cylinders
Ordering Information
Catalog No.
K39400
K39496
≥
Software compatible, inquire
with Koehler Customer Service.
111
Order Qty
1
Accessories
332-002-018
250-000-19F
250-000-19C
250-000-21F
250-000-21C
K39252
K39251
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
Water Separability Tester, 115V 60Hz
Water Separability Tester, 230V 50/60Hz
Cylinder 100mL, graduated from 5 to 100mL
with 1.0mL divisions
ASTM 19F Thermometer. Range: 120 to 134°F
ASTM 19C Thermometer. Range: 49 to 57°C
ASTM 21F Thermometer. Range: 174 to 188°F
ASTM 21C Thermometer. Range: 79 to 87°C
PTFE Policeman
Test Tube Rack
1
1
7
1
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 112
Demulsibility Characteristics of Lubricating Oils
Test Method
Tests the ability of medium to high viscosity oils to separate from water
when water contamination and turbulence are encountered. The sample is
stirred together with distilled water for 5 min. at constant temperature. After
a specified settling period, the degree of separation is measured by volume
and the percentage of water in oil is determined. For lighter oils and
synthetic fluids, the ASTM D1401 Water Separability Test is used.
Demulsibility Apparatus
• Conforms to the specifications of ASTM D2711
• Variable stirrer speed
• Choice of digital or analog bath models
Stirrer–Complete stirrer assembly per Fig. 1 and 2 of ASTM D2711,
including variable high speed drive motor, stainless steel propeller shaft,
top, center and bottom bearings, and steel motor housing with positioning
plate. Entire assembly mounts vertically in K39190/K39199 Constant
Temperature Bath. Built-in tachometer disc allows for precise stirrer
speed adjustment.
K39190 Demulsibility Bath With Stirrers and Funnels
Accessories
Catalog No.
K39120
K39130
K39140
K39149
K39150
360-000-003
250-000-09F
250-000-09C
K39170
K39179
Order Qty
Separatory Funnel
2
With 0-500mL graduations. Meets ASTM specifications.
Solvent Tank. Immerses stirrer assembly for
1
convenient cleaning after testing.
Forced Warm Air Dryer, 115V 60Hz
High output 1400W dryer and brass cylinder
mounted on a sturdy base. Rapidly dries
stirrer assembly after cleaning.
Forced Warm Air Dryer, 220-240V 50/60Hz
1
Sampling Gauge and Centering Device
1
Per Fig. X1.1 of ASTM D2711. Aids in accurately
obtaining 50mL samples from separatory funnels
for the ‘percent water in oil’ determination.
Digital Tachometer
1
Hand held non-contact LCD tachometer
takes measurements up to 3 ft away with ±1rpm
accuracy. Supplied with four 1.5V AA batteries.
ASTM 9F Thermometer
Range: 20 to 230°F
1
ASTM 9C Thermometer
Range: –5 to +110°C
Conditioning Bath, 115V 60Hz
1
Constant temperature water bath holds 8 separatory
funnels in two removable 4-unit racks for conditioning
prior to testing in Demulsibility Apparatus.
Includes microprocessor digital temperature control,
automatic water level control and gabled cover.
Conditioning Bath, 220-240V 50/60Hz
Constant Temperature Baths–Standard model holds two K39103 Stirrers
and two K39120 Separatory Funnels in proper alignment for demulsibility
characteristics testing. Stirrers mount securely on a stainless steel support
plate having brackets for testing and drainage positions. Separate motor speed
controls are provided for each stirrer. All wetted parts are constructed of
stainless steel.
Microprocessor digital temperature control with dual LED displays for
setpoint and actual temperatures and an illuminated bath interior with window
for viewing sample cylinders. Digital LED speed control is provided for each
stirrer.
Specifications
Conforms to the specifications of: ASTM D2711
Capacity: Two (2) sample-water mixtures
Maximum Temperature: 212°F (100°C)
Temperature Control: Microprocessor digital control with LED display
Bath Medium: 9 gal (38.5L) water
Electrical Requirements:
115V 60Hz
220-240V 50/60 Hz
Dimensions: WxDxH in (cm)
Shipping Information
151⁄4x15x37(39x38x94)
Net Weight: 72 lbs (32.6kg)
Shipping Weight 133 lbs (60.3kg)
Dimensions: 25.4 Cu. ft.
Ordering Information
Catalog No.
K39190
K39199
K39103
Order Qty
Demulsibility Bath, 115V, 60Hz
Demulsibility Bath, 220-240V, 50/60Hz
Stirrer**
**Suitable for use with K39190 & K39199
1
2
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
≥
Software compatible, inquire
with Koehler Customer Service.
112
0-107-123_6a_LOils_Layout 1 11/1/12 2:00 PM Page 113
Air Release Properties of Petroleum Oils
K88500 Air Release Value Apparatus
Test Method
The ability of a turbine, hydraulic, or lubricating oil to separate entrained air
is a key performance characteristic in applications where agitation causes
a dispersion of air bubbles in the oil. To determine air release properties,
the sample is heated to a specified test temperature and blown with
compressed air. After the air flow is stopped, the time required for the
air entrained in the oil to reduce in volume to 0.2% is the air bubble
separation time.
Air Release Value Apparatus
•
•
•
•
Conforms to ASTM D3427, IP 313 and related specifications
High accuracy temperature control with digital setpoint and display
Digital control panel leads user from start to finish of test operation
Automatic calculation of final sample density for determination of air
release value
• Redundant overtemperature protection circuitry assures safe operation
Specifications
Included Accessories
Conforms to the specifications of:
ASTM D3427; IP 313; ISO 9120;
DIN 51381; NF E 48-614
Temperature Range:
ambient to 75°C (167°F)
Electrical Requirements:
115V 60Hz, 3.0A
230V 50Hz, 1.5A
230V 60Hz, 1.5A
ASTM 12C Thermometer
Sinkers, 5mL and 10mL
Drying oven
Pressure gauge
Circulating Bath
Air Bath for Sinker
Balance
Platinum Wire
Jacketed Test Vessel
Dimensions lxwxh,in.(cm)
24x28x381⁄4 (61x71x97)
(Air Release Value Apparatus only)
Net Weight for complete system:
225 lbs (103kg)
The Koehler Air Release Value Apparatus consists of a test vessel and air
flow control equipment for delivering heated air at the specified flow rate to a
lubricating oil sample maintained at constant temperature. Microprocessorbased control panel guides user from start to finish of test operation and
provides density calculation and timing operation for measuring the air release
value of the test sample. The system includes drying oven for warming test oil
at temperatures of up to 100°C; circulating bath with digital temperature
controller and air bath for sinker; compressed air heater with digital
temperature controller, overtemperature and overpressure protection circuitry;
pressure gauge; thermometer. Optional Windows® software automatically
measures the time for air release.
≥
Software compatible, inquire
with Koehler Customer Service.
113
Shipping Information
Shipping Weight for complete system:
300 lbs (136kg)
Dimensions: 50.7 Cu. ft.
Ordering Information
Catalog No.
K88500
K88501
K88502
Order Qty
Air Release Value Apparatus,
115V 60Hz
Air Release Value Apparatus,
230V 50Hz
Air Release Value Apparatus,
230V 60Hz
1
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 114
Oxidation Stability – RPVOT & TFOUT
Oxidation Stability of Steam
Turbine Oils by Rotating Pressure Vessel (Bomb)
Oxidation Stability of Inhibited Mineral
Insulating Oil by Rotating Pressure Vessel (Bomb)
Oxidation Stability of Gasoline
Automotive Engine Oils by Thin
Film Oxidation Uptake (TFOUT)
Test Method
The RPVOT (RBOT) procedure employs severe oxidation conditions to
rapidly determine oxidation stability. Suitable for both new and in-service
oils, the RPVOT (RBOT) method is applicable to many types of petroleum
oils. The sample is oxidized in the presence of water and a copper
catalyst in a stainless steel pressure vessel under an initial pressure of
90psi (620kPa). Pressure inside the vessel is recorded electronically or
mechanically while the vessel is rotated at 100rpm at constant
temperature, and the amount of time required for a specified drop in
pressure is the oxidation stability of the sample. A variation of the RPVOT
(RBOT) method is the “Thin Film Oxidation Uptake Test” (TFOUT) for
gasoline automotive engine oils.
RPVOT (RBOT) Test Apparatus
Complete electronic measurement systems for plotting pressure versus
time and temperature in RPVOT (RBOT) and TFOUT testing. Each system
includes transducers, bomb couplings, RTD probe assembly, multiplexer, data
acquisition card, software, and mounting and connecting hardware. Systems
are available in two, three and four pressure vessel configurations, and
additional channels can be added for up to a total of twelve pressure and four
temperature channels.
Page 114
Page 116
Page 117
Page 117
Page 117
Page 115
Page 118
Oxidation Pressure Vessel
• Polished stainless steel construction
• Can be converted for use in the Thin Film Oxidation Uptake Test (TFOUT)
Consists of pressure vessel body, cap and stem with inlet needle valve in
accordance with ASTM specifications. Vessel holds one borosilicate glass
sample container between two PTFE discs. Closure ring tightens by hand to
seal cap to pressure vessel body. Vessel connects to pressure recorder or
rotary transducer and rotates on magnetic carriage in RBOT bath. Withstands
working pressure of 500psi (3450kPa) per ASTM specifications. Stainless
steel construction ensures proper rate of heat transfer. Closure ring is
constructed of chrome plated steel. Includes PTFE fluorocarbon wear disc and
sample container cover disc.
Ordering Information
Catalog No.
K70000
K70092
Oxidata® Pressure Measurement Systems
• Electronic pressure measurement systems exclusively designed for RPVOT
(RBOT), TFOUT and other ASTM oxidation test methods
• Powerful Oxidata® software for Windows® and Windows 95®
environments
• Monitors up to twelve pressure and four temperature channels
• Can be installed to most manufacturer’s RPVOT(RBOT)/TFOUT
test apparatus
• 2, 3 and 4-unit systems
• Oxidata® Pressure Measurement System
• Conforms to ASTM D2112, D2272 and IP 229 specifications for RPVOT
(RBOT) testing
• Conforms to ASTM D4742 specifications for TFOUT testing
For product specifications and ordering information:
Oxidation Pressure Vessels
Oxidation Baths
Beakers and Accessories
Catalysts
Pressure Recorder
Oxidata® Pressure Measurement System
Complete Systems, 2, 3 and 4-Unit
Oxidata® Pressure Measurement System
Koehler pressure measurement systems for RPVOT (RBOT) and TFOUT
feature Oxidata®, a high accuracy pressure measurement software package
designed exclusively for ASTM oxidation test methods. Designed to run in
a Windows® or Windows 95® environment, Oxidata® monitors up to twelve
samples simultaneously, with graphical or tabular display of results.
Each channel can be independently configured for any of the applicable
ASTM standard test methods without compromising the independence or
accuracy of the other channels. Independent start and stop times and user
programmable end points add even greater flexibility.
The software plots your data on screen on line, real time, and automatically saves
your data on disk or to the hard drive during the test to prevent loss of valuable
data. Multiple display options include the ability to view the status of all twelve
pressure channels on screen simultaneously and then click on any one channel
for a graph display; or to view four channels in graphical format simultaneously.
Powerful program features allow you to change axes, have colored plot lines and
zoom in on a specific plot sector to view data in greater detail.
Oxidation Pressure Vessel
Aluminum Insert
Converts standard K70000 Oxidation Pressure Vessel
for use in the TFOUT method
114
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 115
Oxidation Stability – RPVOT & TFOUT
Oxidata® Features and Specifications
• On-line, real time monitoring of up to twelve samples simultaneously results plot directly to the screen for instant monitoring or printout of results
• Menu options for RPVOT (RBOT) or TFOUT testing, as well as for other
ASTM fuel and lubricant oxidation tests
• Programmable automatic end point detection with graphical and tabular
representation
• Each channel can be configured and operated independently with different
start/stop times and different ASTM test methods
• Zoom in feature allows for magnification of any plot sector on any channel
for a more detailed study
• Monitors and reports temperatures of as many as four baths
simultaneously using accessory RTD’s, and calculates and displays average
temperature for each bath. Exports data to spreadsheet programs
such as Microsoft Excel®, Lotus 1-2-3®, etc.
• Temperature and pressure calibration capability
• Data is saved directly to the hard drive during testing to prevent loss of
valuable data
• Operates in Windows® 2000 or higher
• Simple upgrade from existing Koehler data acquisition systems
Oxidata® Software automatically calculates and displays the endpoint of RPVOT
(RBOT)/TFOUT test methods.
Included Accessories (for the pressure measurement systems)
Rotary transducers (connects directly to bomb)
Data acquisition box with USB interface
Oxidata® software
Multiplexer
RTD probe assembly (1)
Mounting Bracket for bath
Connecting cables and hardware
Computer Requirements
Processor: Intel® Pentium II or similar (minimum)
Memory (RAM): 256MB or higher
Speed: 500 MHz or higher
Windows® 2000 or higher
Disk Space: 15 MB free space (minimum)
Communications Port: One USB port
Other Software: Microsoft® Excel (97 or above)
One RS232 port for temperature controller (optional)
Real-time plot screen displays pressure versus time for up to twelve samples
simultaneously.
Ordering Information
The ordering information below is for installation to Koehler equipment.
For other makes of equipment, a few basic hardware items may also be
required - please contact your Koehler representative for assistance.
Oxidata® Retrofit Kits
To upgrade your existing Koehler electronic pressure measurement system to
the Oxidata® software, please refer to page 118.
Catalog No.
RBOT/TFOUT Electronic Pressure Measurement System
K70502-XP
Two-Unit System, 115V 60Hz
K70592-XP
Two-Unit System, 220-240V 50/60Hz
K70503-XP
Three-Unit System, 115V 60Hz
K70593-XP
Three-Unit System, 220-240V 50/60Hz
K70504-XP
Four-Unit System, 115V 60Hz
K70594-XP
Four-Unit System, 220-240V 50/60Hz
115
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 116
Oxidation Stability – RPVOT & TFOUT
Oxidation Baths
• Two, three and four-pressure vessel models
• Conforming to ASTM requirements for RPVOT (RBOT) and TFOUT testing
Constant temperature bath rotates oxidation pressure vessels at 100rpm at an
angle of 30° in accordance with ASTM specifications. Includes drive system
and oil bath with electronic solid state temperature control. Meets ASTM
requirements for heat transfer capability and temperature control precision.
A convenient carriage arrangement allows the oxidation vessels to be inserted
quickly and securely in the drive system. A strong magnet holds the vessel in
place while locating pins in the carriage engage the base of the vessel. PTFE
guides support the pressure vessel stem for added stability. If the vessel
becomes obstructed for any reason, the magnetic carriage releases it to
prevent damage. A chain and sprocket drive system powered by a heavy duty
capacitor start motor rotates the vessel carriages at 100rpm. Drive shafts ride
on PTFE fluorocarbon bearings which provide extended service and are
compatible with silicone heat transfer fluids and other types of bath oils.
Bath temperature is controlled within ASTM specified limits by an electronic
solid state controller with °C/°F switchable digital setpoint and display.
Overtemperature protection is provided by a built-in limit control that
automatically interrupts power to the bath when bath liquid temperature
exceeds 16.7°C (30°F) above the temperature setting or 177°C (350°F). Power
must then be manually restored by the operator after checking the cause of the
problem. Pressure vessel carriage vanes circulate the bath oil during testing to
ensure temperature uniformity, and an auxiliary stirrer can be operated
between tests to prevent sludging of non-silicone bath oils.
The bath interior is constructed of welded stainless steel and is fully insulated.
A hinged section of the bath cover provides easy access to the vessel
carriages. Vapor barriers in the cover close around the vessel stems to contain
vapors from the hot bath medium. A chemical resistant polyurethane finish
protects the bath exterior and control cabinet.
Specifications
Conforms to the specifications of: ASTM D2112, D2272, D4742; IP 229
Capacity: 2, 3 or 4 oxidation pressure vessels
Temperature Control:
Maximum Temperature: 200°C (392°F)
Control Stability: ±0.02°C (±0.04°F)
Heater Range:
2 and 3-pressure vessel models: 0-2750W
4-pressure vessel models: 0-3750W
Recommended Bath Medium: high temperature silicone heat transfer fluid
(355-001-002 or 355-001-004—page 8)
Drive System: 100rpm positive drive transmission powered by a continuous
duty 1⁄2hp ball bearing motor with built-in gear reducer
Ordering Information
Catalog No
K70200
K70290
K70300
K70390
K70400
K70490
Capacity
2 oxidation
vessels
3 oxidation
vessels
4 oxidation
vessels
Electrical Requirements
220-240V 60Hz, 17.17A
220-240V 50Hz, 17.17A
220-240V 60Hz, 17.17A
220-240V 50Hz, 17.17A
220-240V 60Hz, 21.5A
220-240V 50Hz, 21.5A
Bath Capacity, gal (L)
18 (68)
25 (95)
32 (121)
Dimensions, lxwxh,in.(cm)
28x26x33
(71x66x84)
37x26x33
(94x66x84)
46x26x33
(117x66x84)
Net Weight
237 lbs
(107.5kg)
284 lbs
(129kg)
375 lbs
(170kg)
Shipping Weight
356 lbs (161.5kg)
25.3 Cu. ft.
416 lbs (188.7kg)
32 Cu. ft.
542 lbs (245.9kg)
40.3 Cu. ft.
• For verifying bath temperature in accordance with ASTM and
IP test method specifications
Ordering Information
Catalog No.
250-001-37C
250-000-96C
250-000-100C
IP 37C Thermometer. Range: 144 to 156°C
For RPVOT (RBOT) method.
ASTM 96C Thermometer. Range: 120 to 150°C
For ASTM D2112 method.
ASTM 100C Thermometer. Range: 145 to 205°C
For TFOUT method.
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
116
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 117
Oxidation Stability – RPVOT & TFOUT
Oxidation Pressure Vessel Accessories
Pressure Vessel Support Racks
• Sample beakers for RBOT and TFOUT methods
• Oxygen charging accessories
• For convenient handling of oxidation pressure vessel during assembly
and disassembly
Securely holds vessel-recorder assembly in an upright position. Convenient for
assembling and disassembling vessel. Equipped with drainage trough for bath
oil remaining on the vessel exterior after testing.
Ordering Information
Catalog No.
Sample Beakers
K70040
RPVOT (RBOT) Sample Beaker
Borosilicate glass, 175mL
Meets ASTM D2112, D2272 specifications
K70091
TFOUT Sample Container
Borosilicate glass. Meets ASTM D4742 specifications
Ordering Information
Catalog No.
K70017
Pressure Vessel Support Rack, 2-Unit
K70011
Pressure Vessel Support Rack, 3-Unit
K70012
Pressure Vessel Support Rack, 4-Unit
Oxygen Charging Accessories
K70080
Charging Hose. 6 ft (1.8m), with connections
K70082
Female Quick Disconnect Coupling, for charging hose
K70081-1
Male Quick Disconnect Coupling, 1⁄4" NPT,
for oxidation pressure vessel
K70013
Oxygen Pressure Regulator
Catalysts
• For Rotating Pressure Vessel Oxidation Test (RPVOT)
• For Thin Film Oxidation Uptake Test (TFOUT)
Ordering Information
Oxidation Pressure Vessel Accessories
K70050
Silicone O-ring
Replacement seal for pressure vessel lid-body
connection
K70049
Sample Beaker Cover (PTFE disk)
K70048
TFOUT Sample Beaker Cover (PTFE disk)
K70000-03008
Spring. Inserts in pressure vessel to hold
RPVOT (RBOT) beaker and cover in place
K700-0-3A
Spring. Inserts in pressure vessel to hold
TFOUT container and cover in place
Pressure Recorder
• Conforms to ASTM D2112, D2272, D4742 and IP 229 specifications
Records pressure inside oxidation bomb on 24-hour charts. Range 0 to
200psi, accurate to within 2% of scale range, 24-hour spring wound chart
movement. Housed in a finished metal case. Includes cartridge pen.
Catalog No.
Copper Catalyst for RPVOT (RBOT) Method
K70030
Copper Catalyst Coil
Prepared in accordance with ASTM specifications
and packed in a sealed glass container with
nitrogen atmosphere. Ready to use.
K70090
Copper Catalyst Wire
1.63mm electrolytic copper wire in 500 ft (152m) lengths.
K70002
Winding Mandrel
Machined aluminum mandrel for winding copper wire into
coils meeting ASTM specifications.
Mounts on K70003/K70004 Drive Unit
K70003
Drive Unit for Winding Mandrel
Slow speed gear motor mounted on a sturdy base.
Facilitates coil winding procedure. 115V
K70004
Drive Unit for Winding Mandrel
Similar to K70003 but for operation on 220-240V
Ordering Information
Catalyst Package for TFOUT Method
K70093
Catalyst Package A
For simulating IIID engine
test. Includes 3 catalyst packages
K70095
Catalyst Package B
For simulating IIIE engine test.
Includes 3 catalyst packages
Catalog No.
K70010/24 Pressure Recorder, 24-hour
Accessories
K70018
Replacement Cartridge Pen
308-000-004 Recorder Chart, 24-hour
Box of 60 charts
Oxidata® pressure measurement equipment is now available for the RPVOT
(RBOT) and TFOUT Methods. Please refer to page 115.
117
0-107-123_6a_LOilsAA_Layout 1 11/29/12 6:58 PM Page 118
Oxidation – RPVOT & TFOUT
2 Unit RBOT System:
K70200
Oxidation Bath (or K70290)
K70000
Oxidation Pressure Vessel (2)
K70502-XP
Oxidata® Pressure Measurement System (or K70592-XP)
K70002
Winding Mandrel
K70003
Drive Unit (or K70004)
K70017
Pressure Vessel Support Rack
250-001-37C IP 37C Bath Thermometer
K70080
Charging Hose
K70082
Female Quick Disconnect Coupling for charging hose
K70081-1
Male Quick Disconnect Coupling for oxidation
pressure vessel (2)
K70013
Oxygen Pressure Regulator
K70030
Copper Catalyst Coils
Order sufficient
K70090
Copper Catalyst Wire, 500 ft.
quantity to
K70040
Sample Container
meet anticipated
K70050
Silicone O-ring
testing requirements.
4-Unit RBOT System:
K70400
Oxidation Bath (or K70490)
K70000
Oxidation Pressure Vessel (4)
K70504-XP
Oxidata® Pressure Measurement System (or K70594-XP)
K70508
Mounting Bracket for Four-Unit XP System
K70002
Winding Mandrel
K70003
Drive Unit (or K70004)
K70012
Pressure Vessel Support Rack
250-001-37C IP 37C Thermometer
K70080
Charging Hose
K70082
Female Quick Disconnect Coupling for charging hose
K70081-1
Male Quick Disconnect Coupling for oxidation
pressure vessel (4)
K70013
Oxygen Pressure Regulator
K70030
Copper Catalyst Coil
Order sufficient
K70090
Copper Catalyst Wire, 500 ft.
quantity to
K70040
Sample Container
meet anticipated
K70050
Silicone O-ring
testing requirements.
3-Unit RBOT System:
K70300
Oxidation Bath (or K70390)
K70000
Oxidation Pressure Vessel (3)
K70503-XP
Oxidata® Pressure Measurement System (or K70593-XP)
K70002
Winding Mandrel
K70003
Drive Unit (or K70004)
K70011
Pressure Vessel Support Rack
250-001-37C IP 37C Thermometer
K70080
Charging Hose
K70082
Female Quick Disconnect Coupling for charging hose
K70081-1
Male Quick Disconnect Coupling for oxidation
pressure vessel (3)
K70013
Oxygen Pressure Regulator
K70030
Copper Catalyst Coils
Order sufficient
K70090
Copper Catalyst Wire, 500 ft.
quantity to
K70040
Sample container
meet anticipated
K70050
Silicone O-ring
testing requirements.
For TFOUT testing, make the following substitutions:
K70091
Sample Beaker (replaces K70040)
K70092
Aluminum Insert (2, 3 or 4)
TFOUT Catalyst Package (in lieu of K70030, K70090,
K70095
K70002, K70003)
}
}
}
}
250-000-100C ASTM 100C Thermometer (replaces 250-001-37C)
Oxidata® Retrofit Kits
To upgrade existing DOS-based Koehler electronic pressure measurement
systems to the Oxidata® system. Kits include Oxidata® software, data
acquisition card, multiplexer board, RTD probe assembly and connecting
cables. Does not include rotary transducers or bath mounting bracket.
For information on upgrading other makes of equipment to the Oxidata®
system, please contact your Koehler representative.
Ordering Information
Catalog No.
K70502RETRO 2-Unit Oxidata® Pressure Measurement System
without Transducers, 115V 60Hz
K70592RETRO 2-Unit Oxidata® Pressure Measurement System
without Transducers, 220-240V 50/60Hz
K70503RETRO 3-Unit Oxidata® Pressure Measurement System
without Transducers, 115V 60Hz
K70593RETRO 3-Unit Oxidata® Pressure Measurement System
without Transducers, 220-240V 50/60Hz
K70504RETRO 4-Unit Oxidata® Pressure Measurement System
without Transducers, 115V 60Hz
K70594RETRO 4-Unit Oxidata® Pressure Measurement System
without Transducers, 220-240 50/60Hz
Accessories
K70500
K70519
Rotary Transducer
Includes electronic transducer and rotating stainless
steel housing
RTD Kit, for monitoring the temperature
of an additional bath
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
118
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 119
Oxidation Stability and Corrosiveness of Petroleum Oils
Test Method
Various methods are available for testing the resistance to oxidation and/or
the corrosiveness of lubricants, insulating oils, hydraulic oils and distillate
fuel oils. The samples are subjected to a metered flow of air at elevated
temperatures, sometimes in the presence of a metal catalyst. Each of the
tests referenced on this page are also represented on other pages in this
section of the catalog.
High Temperature Convertible Oxidation Bath
• Conforms to various ASTM, Federal and International Standards
• Removable racks hold different types of glassware for different tests
• Equipped with flowmeters or digital mass flow controls to measure and
control the required flow rates
• Microprocessor digital temperature control
High temperature liquid bath for oxidation stability and corrosiveness tests
at temperatures of up to 200°C. Available in different configurations for
convertibility between several oxidation stability and corrosivity test methods
including Cummins oxidation test. Removable rack/top plate assemblies
remove and install with minimum effort to easily convert the bath between
test methods. For most test methods, twelve sets of glassware can be
accommodated in each rack assembly. Select flowmeters or digital mass flow
control to maintain air flow at the required rates. Microprocessor PID control
provides quick temperature stabilization without overshoot, and the bath is
protected by an overtemperature control circuit that interrupts power should
bath temperature exceed a programmed cut-off point. Dual LED displays provide
actual and setpoint temperature values in °C/°F format. Communication
software (RS232, etc.) ramp-to-set and other enhanced features are available
as extra cost options. Contact your Koehler representative for information.
Specifications
Ordering Information
Catalog No.
Please contact your Koehler representative for information on glassware
racks and airflow control options prior to order placement.
Conforms to the specifications of*:
ASTM D943, D2274, D2440, D2893, D4310, D4636, D4871**, D5968,
D6594; DIN 51394, 51586, 51587; FTM 791-5307, 791-5308
*with the appropriate glassware rack and flow control equipment installed
–see ordering information.
**Modified versions of this equipment are available for D4871 (UOT)
test method.
Capacity: Twelve (12) sets of glassware. For ASTM D5968, FTM 791-5307,
and FTM 791-5308, only ten (10) sets of glassware.
Temperature Range: Ambient to 200°C
Temperature Control Accuracy: 0.2°F (0.1°C)
Bath Medium: Silicone heat transfer fluid
Flow Rate: As specified for ASTM or applicable specifications
Electrical Requirements:
115V 60Hz, Single Phase, 27.3A
220-240V 50/60Hz, Single Phase, 14.6A
K12230
K12239
High Temperature Convertible Oxidation Bath,
115V 60Hz
High Temperature Convertible Oxidation Bath,
220-240V 50/60Hz
Accessories
K1223-R943
K1223-R2440
K1223-R4636
K1223-3L
K1223-10L
Dimensions Ixwxh,in.(cm)
Bath (without glassware): 251⁄2x24x42(65x61x107)
Sample Rack for D943, D2274, D2983, D4310 testing
Sample Rack for D2440 testing
Sample Rack for D4636, D5968, D6594 testing
Flowmeter Stand with Flowmeters for D943,
D2274, D2440, D4310 testing (range 3 ±0.1 L/hr)
Flowmeter Stand with Flowmeters for D2893, D4636,
D5968, D6594 testing (range to 10 ±0.5 L/hr)
To order glassware and other accessories please refer to the pages in
this section of the catalog that correspond to the test methods that you
will be following.
Shipping Information (without glassware)
Shipping Weight: 213 lbs (96.6kg)
Dimensions: 29 Cu. ft.
Digital Flowmeter option
is available for this unit.
K12230 High Temperature Convertible Oxidation Bath
≥
Software compatible, inquire
with Koehler Customer Service.
119
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 120
Oxidation
Oxidation Characteristics of
Inhibited Mineral Oils
Sludging and Corrosion Tendencies of Inhibited
Mineral Oils
Oxidation Stability of Distillate
Fuel Oil (Accelerated Method)
Oxidation Characteristics of
Extreme-Pressure Lubrication Oils
Test Method
Evaluates oxidation stability by subjecting the sample to a temperature of 95°C
in the presence of oxygen or dry air. For inhibited mineral oils, the sample is
reacted with oxygen in the presence of water and an iron-copper catalyst.
Oxidation Stability Apparatus
•
•
•
•
•
Thirty and sixty-place liquid baths for high volume testing requirements
Eight and twelve-place liquid baths for benchtop placement
Twelve-place solid block bath
Conforming to ASTM and related test method specifications
Special baths for ASTM D2893 and AOCS CD12-57 tests
For product specifications and ordering information:
30 and 60-place Oxidation Baths - page 121
Solid-Block Oxidation Bath - page 121
Oxidation Cell Glassware and Accessories - page 122
Iron-Copper Catalyst and Thermometers - page 122
K12219 Oxidation Stability Bath
Eight and Twelve-Place Oxidation Baths
• Conforming to ASTM and related test method specifications
Constant temperature baths with solid state temperature control, calibrated
flowmeters and condenser water manifold for oxidation stability tests on fuels
and lubricants. Individual flowmeters and control valves for each oxidation cell
deliver air flow at the rate of 3L/h. Condenser water manifold has individual
control valves for each cell. Microprocessor PID control provides quick
temperature stabilization without overshoot, and the bath is protected by a
redundant overtemperature control circuit that interrupts power should
bath temperature exceed a programmed cut-off point. Display provides
actual setpoint temperature values in °C/°F format. Communications
software (RS232, etc.), ramp-to-set and other enhanced features are
available as extra cost options. Double-wall insulated baths are equipped
with copper immersion heaters and a 1⁄20 hp circulation stirrer. Stainless
steel bath interior has a built-in support rack and overflow/drain to immerse
the test cells at the required depth. Order oxidation cell glassware and
accessories separately.
Specifications
Conforms to the specifications of:
ASTM D943, D2274, D2893*, D4310, D6158; AOCS CD12-57**
DIN 51586, 51587; ISO 4263, ISO 12205; NF M 07-047; NF T 60-150
Test Capacity: 8 or 12 oxidation cells
Temperature Range: ambient to 212°F (100°C)
Temperature Control Stability: ±0.2°F (±0.1°C)
Bath Medium: white technical oil
Bath Capacity:
8-place model: 10 gal (37.8L)
12-place model: 19 gal (71.9L)
Electrical Requirements:
8-place model: 115V 60Hz, Single Phase, 13.0A
220-240V 50/60Hz, Single Phase, 6.8A
12-place model: 115V 60Hz, Single Phase, 32.6A
220-240V 50/60Hz, Single Phase, 17.0A
Ordering Information
Dimensions lxwxh,in.(cm)
Catalog No.
K12200
Oxidation Bath, 8-Unit, 115V 60Hz
K12290
Oxidation Bath, 8-Unit, 220-240V 50/60Hz
K12212
Oxidation Bath, 12-Unit, 115V 60Hz
K12219
Oxidation Bath, 12-Unit, 220-240V 50/60Hz
*Modified versions of this equipment are available for ASTM D2893
**“Oxidation Characteristics of Extreme Pressure Lubricating Oils” and
AOCS CD12-57 “Fat Stability-Active Oxygen Method.” Information will be
furnished upon request.
8-place model: 171⁄2x25x42 (44x64x107)
12-place model: 22x14x42 (57.15x35.56x107)
Shipping Information:
Shipping Weight:
8-place model: 137 lbs (62.1kg)
12-place model: 213 lbs (96.6kg)
Dimensions:
8-place model: 29 Cu. ft.
12-place model: 29 Cu. ft.
Digital Flowmeter option
is available for this unit.
≥
Software compatible, inquire
with Koehler Customer Service.
120
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 121
Oxidation
30- and 60-Place Oxidation Baths
• Convenient operation and servicing of thirty or sixty test cells
• Complete bath temperature, water level, air flow and condenser water systems
Constant temperature water baths for high volume oxidation stability
applications. Provides temperature control, metered air flow and condenser
water supply controls for as many as thirty or sixty cells in a single system,
eliminating the need for multiple water and electrical feeds and oxygen supply
tanks. Microprocessor PID control provides quick temperature stabilization
without overshoot, and the bath is protected by a redundant overtemperature
control circuit that interrupts power should bath temperature exceed a
programmed cut-off point. Display provides actual setpoint temperature
values in °C/°F format. Communications software (RS232, etc.),
ramp-to-set and other enhanced features are available as extra cost options.
A 6 or 12kW heat exchanger with heavy duty magnetic drive circulation pump
provides rapid and uniform heat transfer throughout the bath. Bath liquid
depth is automatically maintained within ASTM specified tolerances by an
electronic water level control system. Two banks of individually controlled
flowmeters maintain the required oxygen flow rate to each test cell, and
condenser water control valves for each cell are mounted on manifolds along
the sides of the bath. A centrally mounted trough collects condenser waste
water for convenient disposal or recirculation through an external cooling
device. Bath interior is constructed of heavy gauge welded stainless steel. All
components are easily accessible for servicing if required. Supplied with a
sturdy finished angle-iron frame for floor standing installation. Order oxidation
cell glassware and accessories separately.
Specifications
Conforms to the specifications of:
ASTM D943, D2274, D2893*, D4310, D6158; ISO 4263, 12205
AOCS CD12-57*; DIN 51586, DIN 51587; NF M 07-047; NF T 60-150
Temperature Control Stability: ±0.1°C (±0.2°F)
Oxygen Flow Rate: 3L/h to each test cell, individually controlled
Bath Capacity:
30-place model: 60 gal (227L)
60-place model: 114 gal (432L)
Electrical Requirements:
30-place model: 220-240V 50/60Hz, Single Phase, 28A
60-place model: 220-240V 50/60Hz, Single Phase, 54A
Other electrical configurations are available upon request.
Dimensions lxwxh,in.(cm)
30-place model: 43x55x52 (109x140x132)
60-place model: 43x78x52 (109x198x132)
Shipping Information
Shipping Weight:
30-place model: 892 Ibs (404.6kg)
60-place model: 995 lbs (451.3kg)
Dimensions:
30-place model: 94 Cu. ft.
60-place model: 148 Cu. ft.
Ordering Information
Catalog No.
K12330
K12339
K12300
K12395
Advanced Communications Software Package for Data Management
12-Place Solid-Block Oxidation Bath
• Accommodates twelve oxidation cells
• Microprocessor digital temperature control
Constant temperature aluminum block oxidation bath with flowmeters and
condenser water manifold for twelve cells. Insulated solid block design
provides efficient operation at temperatures of up to 450°F (232°C).
Microprocessor temperature control unit features digital setpoint and display
and built-in overtemperature protection. Includes individual flowmeters and
control valves for each cell, delivering air flow at the rate of 3L/h. Condenser
water manifold has individual control valves for each cell. Order oxidation cell
glassware and accessories separately.
Specifications
Conforms to the specifications of:
ASTM D943, D2274, D2893*, D4310, D6158; AOCS CD12-57*;
DIN 51586, 51587; ISO 4263, 12205; NF M 07-047; NF T 60-150
Testing Capacity: 12 oxidation cells
Maximum Temperature: 450°F
Temperature Control Stability: ±0.2°F (±0.1°C)
Air Flow Rate: 3L/h
Electrical Requirements: 220-240V 50/60Hz, Single Phase, 16A
Dimensions lxwxh,in.(cm)
Shipping Information
30x10x43 (76x25x109)
Net Weight: 345 lbs (156.5kg)
Shipping Weight: 440 lbs (199.6kg)
Dimensions: 12 Cu. ft.
Solid block baths meet temperature control and other requirements of ASTM
and related methods. While the aluminum block design offers operating
advantages over the standard oil bath, it should be noted that many applicable
specifications for this test call for a liquid bath medium.
Ordering Information
30-Place Oxidation Stability Bath, 220-240V 60Hz
30-Place Oxidation Stability Bath, 220-240V 50Hz
60-Place Oxidation Stability Bath, 220-240V 60Hz
60-Place Oxidation Stability Bath, 220-240V 50Hz
Catalog No.
K12201
Photograph, thermometers, and additional accessories for
oxidation stability testing appear on page 122.
*Modified versions of this equipment are available for ASTM D2893
“Oxidation Characteristics of Extreme Pressure Oils” and AOCS CD12-57 “Fat
Stability-Active Oxygen Method.” Information will be furnished upon request.
*Modified versions of this equipment are available for ASTM D2893 “Oxidation
Characteristics of Extreme Pressure Lubricating Oils” and AOCS CD12-57 “Fat
Stability Active Oxygen Method.’’ Information will be furnished upon request.
Digital Flowmeter option
is available for this unit.
Available option for 30- and 60-place Oxidation Baths–temperature/pressure
recorder with built-in alarms for low pressure and over/under temperature.
Please call or write for specifications and ordering information.
≥
12-Place Solid Block Oxidation Bath,
220-240V 50/60Hz
Software compatible, inquire
with Koehler Customer Service.
121
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 122
Oxidation
K12300 60-Place Oxidation Bath
Shown with optional pressure-temperature recorder
Iron-Copper Catalyst
Oxidation Cell Glassware and Accessories
For ASTM D943 and D4310
Ordering Information
Ordering Information
Catalog No.
K12210
Catalog No.
K12281
Oxidation Cell Assembly for ASTM D943 and D4310
Includes oxidation cell, condenser, oxygen delivery tube,
thermometer bracket, oil level indicator strip, syringe
sampling tube, sampling tube holder, spacer,
PTFE stopper and O-rings
K122-0-18
Oxygen Delivery Tube
K122-0-19
Oxidation Test Tube
K122-0-20
Condenser
K122-0-21
Thermometer Bracket
K122-0-22
Oil Level Indicator Strip
K122-0-23
Syringe Sampling Tube Holder
K122-0-27
PTFE Stopper
K122-0-28
Syringe Sampling Spacer
K122-0-30
Syringe Sampling Tube
AS568-009-V14 O-rings
K24000
K12250
K12260
380-100-001
For ASTM D2274, order one each K122-0-18 Oxygen Delivery Tube,
K122-0-19 Oxidation Test Tube, and K122-0-20 Condenser for each cell.
Catalyst Coil
Low-metalloid steel wire and electrolytic copper wire
wound in a double spiral conforming to ASTM
specifications. Packed in a sealed glass tube with a
nitrogen atmosphere. Ready for use.
Wire Coiling Mandrel
Mounts on bench for winding steel and copper wire into
catalyst coils meeting ASTM specifications.
Steel Wire
Low metalloid steel wire, 0.0625" (1.59mm) diameter,
for catalyst coils. Supplied in 1000 ft (304.8m) lengths.
Copper Wire
Electrolytic copper wire, 0.064" (1.63mm) diameter, for
catalyst coils. Supplied in 1000 ft (304.8m) lengths.
Silicone Carbide Paper
Used to polish steel and copper wire prior to winding
into catalyst coils. 100 grit.
Thermometers
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
Ordering Information
Catalog No.
250-002-001
Digital Flowmeter option
is available for this unit.
250-000-40C
122
Oxidation Cell Thermometer
Range: 80 to 100°C. For ASTM D943 and D4310.
ASTM 40C Thermometer
Range: 72 to 126°C. For constant temperature baths.
0-107-123_6a_LOils_Layout 1 10/24/12 11:18 AM Page 123
Oxidation Stability of Mineral Insulating Oils
Test Method
Determines oxidation stability of mineral transformer oils by measuring
the amount of sludge and acid formed under prescribed accelerated
aging conditions.
Oxidation Stability Bath
• Conforms to ASTM D2440 specifications
• Microprocessor temperature control with digital display and
overtemperature cut-off
• Six-sample testing capacity
Constant temperature oil bath for testing oxidation stability of mineral
insulating oils. Immerses six oil receptacles at the required depth per
ASTM specifications at 110°C ± 0.5°C, and controls oxygen flow to each
sample at the rate of 1L/h ± 0.1L/h through six independent flowmeters
mounted on a common manifold. Insulated double-wall stainless steel
bath has microprocessor temperature control with °C/°F switchable
digital setpoint and display. Operator and equipment are protected by an
overtemperature control circuit which automatically interrupts power to
the unit when bath temperature exceeds a programmed cut-off point.
Communications software (RS232, etc.), ramp-to-set and other enhanced
features are available as extra cost options. Contact your Koehler
representative for information. Order bath thermometer drying tower and
catalyst separately.
Ordering Information
Catalog No.
K12100
K12100 Oxidation Stability Bath
K12190
Specifications
Conforms to the specifications of:
ASTM D2440
Capacity: Six samples
Temperature Range: ambient to 260°F (127°C)
Circulator: 1⁄20hp impeller
Bath Capacity/Medium: 2.5 gal (9.5L) white technical oil
Electrical Requirements:
115V 60Hz, Single Phase, 8.1A
220-240V 50/60Hz, Single Phase, 4.2A
332-005-010
332-005-011
250-000-95C
Oil Receptacle and Head (6)
355-001-001
Dimensions lxwxh,in.(cm)
355-001-003
14x15x22 (36x38x56)
Net Weight: 31 lbs (14.1kg)
Copper Catalyst Coils
Sealed in a glass jar with a nitrogen
atmosphere. Pack of 24 (12 sets)
Drying Tower
250mL with ground glass stopper
and side tubes
Glass Filter Crucible
ASTM 95C Thermometer
Range: 100 to 130°C
White Technical Oil
1 gal container. See page 8 for specifications.
White Technical Oil
5 gal container. See page 8 for specifications.
1
1
1
1
3
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
Shipping Weight: 61 lbs (27.7kg)
Dimensions: 14.4 Cu. ft.
Digital Flowmeter option
is available for this unit.
1
Accessories
K12130
Included Accessories
Shipping Information
Order Qty
Oxidation Stability Bath,
115V 60Hz
Oxidation Stability Bath,
220-240V 50/60Hz
≥
Software compatible, inquire
with Koehler Customer Service.
123
0-124-138_6b_LOils_Layout 1 10/24/12 11:29 AM Page 124
Corrosiveness and Oxidation Stability
Corrosiveness and Oxidation Stability of
Hydraulic Oils, Aircraft Turbine Engine Lubricants,
and Other Highly Refined Oils
Test Method
Evaluates the ability of a lubricant to resist oxidation and the formation
of corrosive acid compounds by subjecting a sample to accelerated
oxidation conditions in a catalytic environment. The sample is
maintained at elevated temperature and subjected to a controlled air
flow while in the presence of a series of test specimens made of
metals commonly found in actual service conditions.
Corrosiveness and Oxidation Stability Test Apparatus
•
•
•
•
K35100 FTM 791-5307 Model with accessory glassware
Constant temperature block baths for corrosivity and oxidation stability
determinations on hydraulic oils, aircraft turbine lubricants, transmission
fluids and other highly refined oils. Insulated aluminum block provides
safe, efficient performance at operating temperatures of up to 750°F
(399°C). Microprocessor temperature control has °C/°F switchable digital
setpoint and display. Operator and equipment are protected by an
overtemperature control circuit which automatically interrupts power to
the unit should block temperature exceed a programmed cut-off point.
Communications software (RS232, etc.), ramp-to-set and other enhanced
features are available as extra cost options. Contact your Koehler
representative for information. Air flow is controlled at the specified rate
by six individually adjustable flowmeters mounted on a common manifold.
Includes inlet valve and outlet fitting for condenser water supply and
support rack for glassware.
Specifications
Ordering Information
Conforms to the specifications of:
ASTM D4636, D5968, D6594; FTM 791-5307, 791-5308;
IHC BT-10; DIN 51394
Capacity: 6 test cells
Temperature Range:125 to 750°F (51.7 to 399°C)
Temperature Control Stability: ±1°F (±0.5°C)
Air Flow Rate: ASTM D4636/FTM 791-5307: 10L/h
FTM 791-5308: 3L/h and 5L/h (dual range flowmeters)
IHC BT-10: 3L/h (50mL/min.)
Electrical Requirements: 220-240V 50/60Hz, Single Phase, 15.9A
Catalog No.
Order Qty
Corrosivity and Oxidation Stability Test Apparatus
1
K35100
ASTM D4636, D5968 and FTM 791-5307 Model,
220-240V 50/60Hz
K35000
FTM 791-5308 Model,
220-240V 50/60Hz
K35300
IHC BT-10 Model,
220-240V 50/60Hz
Thermometers
250-000-08F ASTM 8F Thermometer
Range: 30 to 760°F
250-000-08C ASTM 8C Thermometer
Range: –2 to +400°C
Dimensions lxwxh,in.(cm)
321⁄2x141⁄2x411⁄2 (83x37x105)
Net Weight: 271 lbs (122.9kg)
Shipping Information
Shipping Weight: 375 lbs (170.1kg)
Dimensions: 18.5 Cu. ft.
Digital Flowmeter option
is available for this unit.
Models for ASTM, Federal and IHC test methods
Six-sample testing capability
Solid aluminum block design
Microprocessor temperature control with digital display and
overtemperature protection
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
≥
Software compatible, inquire
with Koehler Customer Service.
124
0-124-138_6b_LOils_Layout 1 10/24/12 11:29 AM Page 125
Corrosiveness and Oxidation Stability
Glassware, Test Specimens and Accessories
Metal Test Specimens
Catalog No.
Order Qty
ASTM D4636, D5968, D6594 and FTM 791-5307
K351-0-1
Sample Tube
6
K351-0-2
Sample Tube Head
6
K351-0-3
Air Tube
6
K351-0-4
Thermocouple Tube
6
K351-0-5
Condenser, Allihn Type
6
K351-0-6
Oil Sampling Tube (for D4636)
6
K351-0-7
Spacer
36
K351-0-8
PTFE Adapter
6
K351-0-13
Oil Sampling Tube (for D5968 and FTM 791-5307)
K351-0-14
Specimen Hanger (for D6594)
K293-0-12
Thermocouple, Type J
6
K29319
Digital Thermometer, 220-240V
1
Microprocessor based digital thermocouple
thermometer with ten-channel input.
Monitors Type J thermocouples from sample tubes.
K35090
Test Panel Assembly Fixture
1
Holds square-shaped metal specimens
for tying with cord (for ASTM D4636 Alternate
Procedure and FTM 791-5308)
K35095
Test Panel Assembly Fixture
1
Holds square-shaped metal specimens
for tying with cord (for ASTM D5968)
FTM 791-5308
K350-0-23
K350-0-24
K350-0-25
K35090
IHC BT-10
K353-0-1
K353-0-2
K353-0-3
K353-0-4
Test Tube
Air Tube
Condenser
Test Panel Assembly Fixture
Holds square-shaped metal specimens
for tying with cord.
6
6
6
1
Test Cell
Condenser
Air Tube
Ring Rod
6
6
6
6
Catalog No.
Washer Shaped Specimens for ASTM D4636 Standard Procedure
and for FTM 791-5307
K35110
Bronze
K35120
Mild Steel
K35130
Aluminum Alloy
K35140
Magnesium
K35150
Steel M50
K35160
Silver
K35170
Titanium
Square Shaped Specimens for ASTM D4636 Alternate Procedure
and for FTM 791-5308
K35010
Copper
K35020
Mild Carbon Steel
K35030
Aluminum Alloy
K35040
Magnesium Alloy
K35050
Cadmium Plated Steel
K35060
Silver
K35070
Solid Cadmium (non standard)
K35080
Titanium (non standard)
Square Shaped Specimens for ASTM D5968 and D6594
K35010
Copper
K35011
Lead
K35012
Tin
K35013
Phosphor Bronze
Rectangular Shaped Specimens for IHC BT-10
K353-0-5
Aluminum
K353-0-6
Copper
K353-0-7
Steel
K353-0-8
Brass
Polishing Materials
380-150-001 Silicone Carbide Paper, 150-grit, Pack of 50 sheets
380-240-001 Silicone Carbide Paper, 240-grit, Pack of 50 sheets
380-150-000 Silicone Carbide Grain, 150-grit, 1 lb package
125
0-124-138_6b_LOilsAA_Layout 1 11/29/12 7:06 PM Page 126
Oxidation
Oxidation Stability of Inhibited Mineral Turbine Oils
Oxidation Stability of Straight Mineral Oil
Oxidation Stability of Mineral Insulating Oil
Oxidation Stability of Inhibited Mineral
Insulating Oils
Oxidation Test For Lubricating Oil
Test Method
Oxidation stability is determined by exposing the sample to a measured
oxygen flow at elevated temperature in the presence of metal catalysts.
Oxidation Stability Apparatus (Cigre Bath)
• Conforms to IP specifications
• Twelve-sample testing capability
• Microprocessor programmable high accuracy temperature control
Constant temperature aluminum block type bath for oxidation stability tests in
accordance with the Institute of Petroleum (IP) testing methods.
Accommodates twelve sets of oxidation and absorption tubes. Insulated block
bath operates efficiently at temperatures of up to 200°C (392°F).
Microprocessor PID control provides quick temperature stabilization without
overshoot, and the bath is protected by a an overtemperature control circuit
that interrupts power should block temperature exceed a programmed cut-off
point. Dual LED displays provide actual and setpoint temperature values in
°C/°F format. Communications software (RS232, etc.), ramp-to-set and
other enhanced features are available as extra cost options. Contact your
Koehler representative for information. A bank of twelve flowmeters on a
movable stand regulates oxygen flow at 1 ±0.1L/h to each oil sample per IP
specifications. Includes soap bubble flowmeter for checking oxygen flow rate.
K56100 Cigre Bath with K56110 Glassware
Specifications
Ordering Information
Catalog No.
K56100
K56190
K56200
K56290
Order Qty
Oxidation Stability Apparatus
115V 60Hz
Oxidation Stability Apparatus
220-240V 50/60Hz
Oxidation Stability Apparatus
115V 60Hz
For IP 48 Method.
Oxidation Stability Apparatus
220-240V 50/60Hz
For IP 48 Method
1
Accessories
K56110
Set of Glassware
Includes one each oxidation and absorption tube.
For IP 48, IP 280, IP 306, IP 307, IP 335
12
250-000-09C ASTM 9C Thermometer
Range: –5 to +110°C
(equivalent to IP 15C Thermometer)
1
250-000-41C ASTM 41C Thermometer
Range: 98 to 152°C
(equivalent to IP 81C Thermometer)
A liquid bath version of this equipment to perform the proposed ASTM test
for High Temperature Stability of Distillate Fuels is also available. Please
contact Koehler’s Customer Service for additional information.
Conforms to the specifications of:
IP 48, IP 280, IP 306, IP 307, IP 335
Testing Capacity: Twelve samples
Temperature Range: 80 to 200°C
Temperature Uniformity: ±0.2°C
Air Flow Control:
Standard Model: 1L/h to each sample
IP 48 Model: 15L/h to each sample
Electrical Requirements:
115V 60Hz, Single Phase, 12.1A
220-240V 50/60Hz, Single Phase, 6.3A
Included Accessories
Shipping Information
Soap Bubble Flowmeter
Shipping Weight: 245 lbs (111.1kg)
Dimensions: 16.7 Cu. ft.
Dimensions
Bath: dia.xh,in.(cm)
17x22 (43.2x55.9)
Flowmeter Stand: lxwxh,in.(cm)
24x8x301⁄4 (61x20.3x76.8)
Net Weight: 186 lbs (84.4kg)
Digital Flowmeter option
is available for this unit.
126
For NIST traceable certified thermometers,
please refer to the ASTM Thermometers
sections on pages 184 through 191.
≥
Software compatible, inquire
with Koehler Customer Service.
0-124-138_6b_LOils_Layout 1 10/24/12 11:29 AM Page 127
Thermal Oxidation Stability of Automotive Gear Lubricants
Test Method
Ordering Information
The L-60-1 Performance Test determines the deterioration of gear
lubricants under severe thermal oxidation conditions. The sample
lubricant is tested for 50 hours in a standardized gear box operating under
a predetermined load. An elevated temperature and controlled air flow
are maintained throughout the test and a copper catalyst is employed to
accelerate the breakdown. At the end of the test period, various lubricant
properties are determined by standard testing methods, and the weight
loss of the catalyst is measured. The deposits that are formed on the gear
box surfaces and the catalyst are examined and reported.
Catalog No.
K18660
K18650
L-60-1 Performance Test Apparatus, 220-240V 60Hz
L-60-1 Performance Test Apparatus, 220-240V 50Hz
Accessories
K18661
380-150-001
Test Kit, for one test. Includes GA34 test gear, GA50
test gear, R-14 test bearing, viton shaft seals (2),
O-ring seal, copper test strips (2)
Silicone Carbide Paper, 150-grit (pack of 50)
K18660 L-60-1
Performance Test
Apparatus
L-60-1 Performance Test Apparatus
Specifications
• Conforms to ASTM D5704 and STP512A L-60-1 Performance Test
specifications. Performs the L-60-1 Thermal Oxidation Stability performance test
for API GL-5 gear lubricant service. Consists of a standardized gear box assembly
with motor drive system and digital indicating controls for all test functions.
Conforms to the specifications of:
ASTM D5704; STP512A L-60-1 Performance Test
(formerly CRC L-60 Test); FTM 791-2504
Controls and Monitors:
Sample Oil Temperature: °C/°F, digital setpoint and display, user adjustable
Overtemperature Limit Control: °F, user acceptable
Heating Chamber Air Temperature:°C/°F
Air Flow: L/h, digital setpoint and display, user adjustable
Test Gear Load: Volts DC, Amps. DC, digital display, user adjustable
Sample Oil Temperature Recorder: Programmable microprocessor based
strip chart recorder with digital display, °C/°F
Drive Motor: 1725rpm thermally protected ball bearing type
Alternator: 45 ampere output
Electrical Requirements:
220-240V 60Hz, Single Phase, 15A
220-240V 50Hz. Single Phase, 15A
Gear Case and Drive System
Two spur gears and a test bearing are operated inside a machined stainless
steel case with removable window. The drive gear shaft is coupled to a heavy
duty ball bearing motor loaded by a 45 ampere alternator. The standard
L-60-1 test gear loading value of 128 watts generator output is precisely
maintained by a digitally indicated load bank. All gear box components are
easily accessible for cleaning.
Temperature Control
An insulated heating case with high volume blower encloses the gear box.
Sample oil temperature is maintained at 325°F ± 1°F (162.8 ± 0.6°C) by a digital
indicating controller with PT-RTD sensor. A built-in microprocessor based
recorder produces a test oil temperature chart for reporting purposes.
Overtemperature protection is provided by a separate PT-RTD-sensed controller.
Air Flow Control
A high accuracy mass flow controller with digital indication maintains air flow
to the gear box at a constant 1.1L/h. The self correcting controller maintains
the setpoint flow rate regardless of fluctuations in air input pressure or
temperature. Test cabinet and control cabinet are finished in chemical
resistant polyurethane enamel. Test cabinet has a cover for access to the gear
box and a removable drive motor cover.
Dimensions lxwxh,in.(cm)
Test Cabinet: 24x24x141⁄2 (61x61x37)
Control Cabinet: 231⁄2x231⁄2x173⁄8 (60x60x44)
Net Weight: 330 Ibs (149.7kg)
Shipping Information
Shipping Weight: 498 Lbs (225.9kg)
Dimensions: 29.2 Cu. ft.
127
0-124-138_6b_LOils_Layout 1 10/24/12 11:29 AM Page 128
Rust Preventing Characteristics
Rust Preventing Characteristics of Inhibited
Mineral Oil in the Presence of Water
(Standard and Horizontal Disc Methods)
Test Method
Determines a lubricant’s ability to prevent rusting of metal surfaces.
Suitable for steam turbine oils, gear oils, hydraulic oils and other types of
inhibited mineral oils. A steel test specimen is immersed in a heated
mixture of sample oil and water which is stirred continuously during the
test. After the test period the specimen is examined for rusting. The
standard (ASTM D665) method uses a vertical specimen; the ‘horizontal
disc method’ (ASTM D3603) uses both horizontal and vertical test surfaces.
Rust Preventing Characteristics Oil Bath
K30160 Rust Preventing Characteristics Bath
Specifications
Conforms to the specifications of:
ASTM D665, D3603, D6158; NACE TM-01-72*; IP 135; ISO 7120;
DIN 51355**, DIN 51585; FTM 791-4011, 791-5315**; NF T 60-151
Testing Capacity: Six (6) 400mL sample beakers
Maximum Temperature: 104°C (220°F)
Temperature Control Stability: ±0.5°C (±1°F)
Drive Motor: 1⁄12hp induction motor
Bath Medium: 11 gal (41.6L) white technical oil
Electrical Requirements:
115V 60Hz, Single Phase, 13.0A
220-240V 50 or 60Hz, Single Phase, 6.8A
Included Accessories
ASTM D665 Models (K30160, K30165, K30166)
Steel Test Specimens (6)
Type 2 Plastic Specimen Holders (6)
Plastic Beaker Covers (6)
ASTM D3603 Models (K30161, K30167, K30168)
Horizontal Disc Test Assembly (6) consisting of:
plastic beaker cover
horizontal test specimen
vertical test specimen
fluorocarbon washer
plastic cap
stainless steel support rods and hardware
Dimensions lxwxh,in.(cm)
323⁄4x141⁄4x27 (83x36x69)
Net Weight: 79 lbs (35.8kg)
• Conforms to ASTM D665, D3603 and NACE TM-01-72* specifications
• Accommodates six sample beakers
• Microprocessor programmable high accuracy temperature control
Constant temperature bath with stirrers for rust preventing characteristics
tests. Stirs sample-water mixtures at 1000rpm and controls temperature with
± 0.5°C (± 1°F) stability. Immerses test beakers at the proper depth per ASTM
specifications.
Microprocessor PID control provides quick temperature stabilization without
overshoot, and the bath is protected by an overtemperature control circuit that
interrupts power should bath temperature exceed a programmed cut-off point.
Dual LED displays provide actual and setpoint temperature values in °C/°F
format. Communications software (RS232, etc.), ramp-to-set and other
enhanced features are available as extra cost options. Contact your Koehler
representative for information.
Stainless steel stirrer paddles are driven by a ball bearing type motor through
an improved pulley drive-roller bearing arrangement. Paddles can be raised
and lowered for placement of sample beakers in the bath. Includes test
specimens, holders and beaker covers for ASTM D665 or D3603 testing
(see specifications and ordering information). Stainless steel bath includes
perforated support shelf for beakers and two-position cover plate that adjusts
for either ASTM D665 or D3603 testing. Long-lasting polyester drive belt
improves reliability. Drive train components are protected by a removable steel
guard. All exterior surfaces have stainless steel or chemical resistant
polyurethane enamel finishes.
Ordering Information
Catalog No.
Rust Preventing Characteristics Oil Bath
For ASTM D665
K30160
Rust Preventing Characteristics
Oil Bath, 115V 60Hz
K30165
Rust Preventing Characteristics
Oil Bath, 220-240V 50Hz
K30166
Rust Preventing Characteristics
Oil Bath, 220-240V 60Hz
For ASTM D3603
K30161
Rust Preventing Characteristics
Oil Bath, 115V 60Hz
K30167
Rust Preventing Characteristics
Oil Bath, 220-240V 50Hz
K30168
Rust Preventing Characteristics
Oil Bath, 220-240V 60Hz
Shipping Information
Shipping Weight: 150 lbs (68kg)
Dimensions: 16.2 Cu. ft.
**Accessories for these test methods are available upon request.
≥
Software compatible, inquire
with Koehler Customer Service.
*To order this equipment for the NACE TM-01-72 test please turn to page 98.
128
0-124-138_6b_LOilsAA_Layout 1 11/29/12 7:06 PM Page 129
Rust Preventing Characteristics
K30800 Horizontal Disk Assembly
K30101 Specimen with Holder
Test Specimens
Accessories
Catalog No.
332-002-006
250-000-09F
250-000-09C
K30130
K30150
K30180
380-150-002
380-240-002
K30140
K30130 Chuck
Order Qty
6
Test Beaker, 400mL
for ASTM D665 & D3603
ASTM 9F Thermometer
Range: 20 to 230°F
ASTM 9C Thermometer
Range: –5 to +110°C
Chuck for polishing test specimens
Includes locknut and shaft for
mounting on accessory drive motor.
Drive Motor
Drives K30130 Chuck. Mounted on base.
115V 60Hz
Drive Motor
Similar to K30150 but for operation
on 220-240V 50Hz
Aluminum Oxide Cloth, 150-grit for
preliminary grinding of test specimens
Pack of 50
Aluminum Oxide Cloth, 240-grit for
final polishing of test specimens
Pack of 50
Auxiliary Stirrer Blade - Attaches to stirrer shaft - for
testing heavier than water samples - ASTM D665.
Procedure C.
Catalog No.
K30110
K30100
7
K30119
1
K30101
K30810
K30820
K30800
1
Steel Test Specimen for ASTM D665
Machined to ASTM specifications. Without Holder
Test Specimen with Type 2 Plastic Holder
for ASTM D665
Test Specimen with Type 1 Plastic Holder
for ASTM D665
Test Specimen with Type 2 PTFE Holder
Horizontal Test Specimen for ASTM D3603
Vertical Test Specimen for ASTM D3603
Horizontal Disc Rust Test Assembly for
ASTM D3603. Includes polycarbonate beaker
cover, two stainless steel support rods,
disc carrier and one each horizontal and
vertical test specimens.
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
1
129
0-124-138_6b_LOils_Layout 1 10/24/12 11:30 AM Page 130
Corrosion of Lead by Lubricating Oils
Specifications
Test Method
Measures the corrosiveness of lubricating oils to lead in the presence
of a copper catalyst. Lead and copper test panels are rotated in the test
lubricant under specified test conditions, and the degree of corrosion
is determined by the change in weight of the lead panel.
Lead Corrosion Test Apparatus
• Conforms to FTM 791-5321 specifications
• Six-sample capacity
• Microprocessor programmable high accuracy temperature control
Constant temperature apparatus rotates copper and lead test panels in
lubricant samples to determine corrosiveness to lead per FTM specifications.
Panels are rotated at 600rpm in samples maintained at 163°C (325°F) and
aerated at 0.94L/min. (2.0 Cu. ft./hr.).
Test panel shafts ride on ball bearing spindles driven by a 1⁄15hp motor. A
counterbalanced support bar positions the drive shaft for testing or for
mounting and removal of test panels. When the support bar is raised,
a safety microswitch automatically stops the drive motor to prevent
splashing of hot oil.
Conforms to the specifications of:
FTM 791-5321
Testing Capacity: 6 lubricant samples
Maximum Temperature: 199°C (390°F)
Temperature Control Stability: ±0.05°C (±0.1°F)
Air Flow Control: 0.94±0.047L/min.
(2±0.1 Cu. ft./hr) six (6) flowmeters
mounted on a common manifold
Electrical Requirements:
220-240V 60Hz, Single Phase, 14.5A
220-240V 50Hz, Single Phase, 14.5A
Included Accessories
Dimensions lxwxh,in.(cm)
Copper Test Panels (6)
Lead Test Panels (6)
Mounting Hardware for Panels
39x25x47 (99x64x119)
Net Weight: 214 lbs (97kg)
Shipping Weight: 330 lbs (150kg)
Dimensions: 33.5 Cu. ft.
Ordering Information
Catalog No.
K29900
Fully insulated bath features double-wall stainless steel construction, with
a built-in support rack to suspend test cells vertically at the proper depth.
Microprocessor PID control provides quick temperature stabilization without
overshoot, and the bath is protected by an overtemperature control circuit that
interrupts power should bath temperature exceed a programmed cut-off point.
Dual LED displays provide actual and setpoint temperature values in °C/°F
format. Communications software (RS232, etc.), ramp-to-set and other
enhanced features are available as extra cost options. Contact your Koehler
representative for information. A 1⁄20hp stirrer thoroughly circulates the bath
medium for temperature uniformity. Redundant overtemperature
protection is provided by a built-in backup thermostat. Flowmeters and
valves mounted on a convenient manifold provide individual air flow
control for each test cell.
Digital Flowmeter option
is available for this unit.
Shipping Information
K29990
Order Qty
Lead Corrosion Apparatus,
220-240V 60Hz
Lead Corrosion Apparatus.
220-240V 50Hz
1
Accessories
K29910
250-000-16F
250-000-16C
K29920
K29930
Borosilicate Glass Sample Tube
ASTM 16F Thermometer
Range: 85 to 392°F
ASTM 16C Thermometer
Range: 30 to 200°C
Lead Test Panels
Copper Test Panels
6
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
Stability of Lubricating Oils (Work Factor)
Specifications
Test Method
Determines the stability of a lubricating oil when subjected to an endurance
test in a journal bearing operated under prescribed conditions. After a 100
hour test period, the ‘work factor’ is computed from measured changes in
viscosity, neutralization number and carbon residue.
Navy Work Factor Machine
Conforms to the specifications of: FTM 791-3451.4
Electrical Requirements: 220-240V, 3 Phase, 50/60Hz, 20A
Dimensions lxwxh,in.(cm)
Shipping Information
50x40x60 (127x102x152)
Net Weight: 1378 lbs (625.1kg)
Shipping Weight: 1660 lbs (753kg)
Dimensions: 110 Cu. ft.
• Conforms to FTM 791-3451 specifications
Complete apparatus for the ‘Navy Work Factor’ stability test for lubricating oils.
Consists of bearing and journal, bearing loading device with calibrated springs,
5hp drive system with variable speed control, oil circulation system, and full
instrumentation. Operates the journal bearing at 2000 or 3000rpm under a
specified load. Oil system pressure is maintained at a constant 15 psig
(103 gauge kPa) throughout the test. Includes digital displays of oil pressure
and temperature and a built-in strip chart recorder for hard copy test reports.
130
Ordering Information
Catalog No.
K30000
K30010
Navy Work Factor Machine,
220-240V Specify 50 or 60Hz when ordering
Replacement Test Bearing
0-124-138_6b_LOilsAA_Layout 1 11/29/12 7:06 PM Page 131
Copper Corrosion from Petroleum Products
Test Method
Ordering Information
The Copper Strip Tarnish Test assesses the relative degree of corrosivity of
petroleum products, including lubricating oils. A polished copper strip is
immersed in 30mL of sample at elevated temperature. After the test
period, the strip is examined for evidence of corrosion and a classification
number from 1-4 is assigned based on a comparison with the ASTM Copper
Strip Corrosion Standards.
Catalog No.
K25330
K25339
K25312
Order Qty
Copper Strip Test Tube Bath, 115V 60Hz
1
Copper Strip Test Tube Bath, 220-240V 50/60Hz
Vented Cork
Copper Strip Tarnish Test Apparatus
K25080
Copper Test Strips
17
12.5x1.5-3.0mmx75mm to ASTM specifications
Test Tube, 25x150mm
17
Viewing Test Tube
17
Protects copper strip during inspection or storage
ASTM Copper Strip Corrosion Standard
1
Colored reproductions of tarnished strips encased
in a plastic plaque
Silicone Carbide Paper, FEPA Grade, 220 grit
For polishing of copper strips prior to testing
Pack of 50 sheets
Silicone Carbide Grain, FEPA grade, 150 grit
For final polishing of copper strips prior to testing
1 lb package
Polishing Vise
1
Holds copper strip firmly in place without marring the
edges. Stainless steel. mounted on a composition base
Multi-Strip Polishing Vise. Similar to K25000 but
1
capable of holding four strips at a time
ASTM 12F Thermometer, Range: –5 to +215°F
1
ASTM 12C Thermometer, Range: –20 to +102°C
Accessories
• Conforms to ASTM D130, D6074, D6158 and related specifications
The complete apparatus for the Copper Strip Tarnish Test for lubricating oils
consists of:
Test Tube Bath
Copper Strips
Test Tubes
ASTM Copper Strip Corrosion Test Standard
Surface Preparation Accessories
332-004-004
332-004-002
K25100
380-220-001
Test Tube Bath
• Accommodates 17 test tubes
• Temperature range to 190°C (374°F)
• Microprocessor temperature control with digital display and
overtemperature protection.
Constant temperature bath immerses 16 test tubes for copper strip tarnish tests
of products not requiring a test bomb. Microprocessor temperature control has
°C/°F switchable digital setpoint and display. Operator and equipment are
protected by an overtemperature control circuit which automatically interrupts
power to the unit should bath temperature exceed a programmed cut-off point.
Welded stainless steel double-wall construction with built-in support rack. Fully
insulated. For complete specifications, please refer to page 90.
380-150-003
K25000
K25090
250-000-12F
250-000-12C
Bearing Compatibility of Turbine Oils
Specifications
Test Method
Evaluates the in-service stability of turbine lubricants by running a
sample-lubricated babbit journal bearing for an extended period at high
speed under controlled conditions of load, lubricant flow and temperature.
The change in various properties (viscosity, carbon residue, acidity) is
measured at the end of the endurance test and the bearing is cleaned and
examined for evidence of deposits, corrosion and other changes.
Bearing Compatibility Tester
• Conforms to FTM 791-3452 specifications
• Digital-indicating controls and built-in temperature recorder
Tests the bearing compatibility (lacquering, deposits, corrosion) and stability
of turbine lubricants when subjected to an endurance test. Consists of bearing
housing assembly with test bearing and support bearings, hydraulic loading
device, oil circulation system with thermostatic and hydrostatic control, and
powerful 5hp variable speed drive system. Digital LCD controls monitor oil
pressure, oil temperature and spindle rpm, and a built-in strip chart recorder
plots oil temperature at three different points—at the bearing housing, in-line,
and in the reservoir. Equipped with overtemperature and low pressure cut-off
switches and a cartridge oil filter for convenient ‘flush run’ operation. All
components are mounted in a sturdy angle iron frame. A removable steel
guard protects drive train components.
Conforms to the specifications of: FTM 791-3452
Journal Drive Motor: 5hp variable speed, with digital 0-3500rpm control.
Fan cooled with thermal overload protection.
Lubricant Flow: 3.8L/min. gear pump recirculating 1.9-23L/min.
of test lubricant to support bearing and test bearing.
Digital oil pressure circulation.
Temperature Control: Sump temperature (0-500°F) with digital indication
and recording of temperature at bearing housing, sump and in-line.
Bearing Load: Hydraulic loading device maintaining 1520 kPa (220 psig) on
the loading bearing.
Electrical Requirements:
200-240V 50/60Hz, 3-Phase, 20A
380V 50/60Hz, 3-Phase, 12A
440V 50/60Hz, 3-Phase, 10A
Ordering Information
Catalog No.
K29800
Shipping Information
48x36x54 (122x91x137)
Net Weight: 1300 lbs (589.7kg)
Shipping Weight: 1582 lbs (717.6kg)
Dimensions: 101.7 Cu. ft.
Order Qty
1
Accessories
K29801
Dimensions lxwxh,in.(cm)
Bearing Compatibility Tester
Specify electrical requirements when ordering.
Test Bearing
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections
on pages 184 through 191.
131
0-124-138_6b_LOils_Layout 1 10/24/12 11:30 AM Page 132
Cloud Point and Pour Point of Petroleum Products
Test Method
Cloud point and pour point are indicators of the lowest temperature of
utility for petroleum products. The sample is periodically examined while
it is being cooled in the cloud and pour point apparatus. The highest
temperature at which haziness is observed (cloud point), or the lowest
temperature at which movement of the oil is observed (pour point),
is reported as the test result.
Cloud and Pour Point Test Equipment
• Conforms to ASTM D97, D2500 and related specifications
• Compact four-place portable chamber
• Mechanically refrigerated models with factory preset cold baths
Cloud and Pour Point Chamber–Immerses four copper test jackets in
suitable freezing mixtures at the required depth per ASTM specifications.
Available with inlet and outlet connections for circulating refrigerated
coolant from an external source. Consists of steel exterior housing with
polyurethane enamel finish and all copper interior for corrosion
resistance. Removable composition top plate and 1⁄2" (13mm) cork
insulation around interior aid in cold retention. Supplied with copper
jackets, gaskets, disks, and thermometer holders for test jars and cooling
bath. Order test jars and thermometers separately.
K46100 Refrigerated Bench Model
Mechanically Refrigerated Baths–Bench-model and floor-model test
units with multiple four-jacket mechanically refrigerated baths, each
factory preset at a different temperature for convenient cloud and pour
point testing. Bench model has three baths, set at +32, 0 and -27°F (0, -18
and -33°C); floor model available with either four or five baths, set at +32, 0,
-27 and -60°F (0, -18, -33 and -51°C) and +32, 0, -27, -60 and -92°F (0, -18,
-33, -51, and -69°C) respectively. Each bath has a phenolic top plate with
ports for thermometer and four copper test jackets. Synthetic sponge
covers over each top plate and gasketed hoods over each bath prevent
excessive ice accumulation around the test jackets. Cascade hermetic
refrigeration system provides reliable long term service. Bath interior is made
of stainless steel, cabinet is constructed of polyester-epoxy finished steel
housing. Floor model rides on swivel castors. Supplied with test jackets,
gaskets, disks, and thermometer holders for test jars and cooling baths.
Ordering Information
Catalog No.
Cloud and Pour Point Chamber
K46000 Cloud and Pour Point Chamber
K46001 Cloud and Pour Point Chamber, with inlet/outlet fittings
Refrigerated Models:
K46100 Cloud and Pour Point Bath, Bench Model, 115V 60Hz
K46195 Cloud and Pour Point Bath, Bench Model, 220-240V 50Hz
K46196 Cloud and Pour Point Bath, Bench Model, 220-240V 60Hz
K46300 Cloud and Pour Point Bath, Floor Model, 115V 60Hz
K46395 Cloud and Pour Point Bath, Floor Model, 220-240V 50Hz
K46396 Cloud and Pour Point Bath, Floor Model, 220-240V 60Hz
K46500 Cloud and Pour Point Bath, Floor Model, 5-Bath, 115V 60Hz
K46595 Cloud and Pour Point Bath, Floor Model, 5-Bath, 220-240V 50Hz
K46596 Cloud and Pour Point Bath, Floor Model, 5-Bath, 220-240V 60Hz
Specifications
Conforms to the specifications of:
ASTM D97, D2500, D5853, D6074, D6158; IP 15, 219;
ISO 3015, 3016; DIN 51597; FTM 791-201; NF T 60-105
Electrical Requirements:
Model K46100 Refrigerated Bench Model:
115V 60Hz, Single Phase, 12.2A
220-240V 50/60Hz, Single Phase, 6.9A
Model K46300/K46500 Refrigerated Floor Model:
115V 60Hz, Single Phase, 17.7A
220-240V 50/60Hz, Single Phase, 9.7A
Accessories
332-004-001
250-000-05F
250-000-05C
250-000-06F
250-000-06C
K46120
K46130
AS568-219
K460-0-8
K460-1-7B
Test Jar
Clear, flat bottom jar with sample height graduation
ASTM 5F Thermometer, range: –36 to +120°F
ASTM 5C Thermometer, range: –38 to +50°C
ASTM 6F Thermometer, range: –112 to +70°F
ASTM 6C Thermometer, range: –80 to +20°C
Cork Disk
Foam Sponge Disc
Gasket, for test jar
Thermometer Holder, for test jar
Copper Jacket
Dimensions
For NIST traceable certified thermometers, please refer to the ASTM Thermometers sections on
pages 184 through 191.
Custom configurations of this bath are available. Please contact Koehler Customer Service for
additional information.
≥
Shipping Information
Shipping Weight:
K46000: dia.xh,in.(cm)
K46000: 18 lbs (8.2 kg)
101⁄2x12 (27x30)
K46100: 550 lbs (250 kg)
K46100: lxwxh,in.(cm)
K46300/K46500: 605 lbs (275 kg)
30x28x35 (76x71x89)
K46300/K46500: lxwxh,in.(cm) Dimensions:
K46000: 2.6 Cu. ft.
44x38x4 (112x97x115)
K46100: 14.1 Cu. ft.
Net Weight:
K46300/K46500: 60.6 Cu. ft.
K46000: 14 lbs (6.3 kg)
K46100: 340 Ibs (155 kg)
K46300/K46500: 392 lbs (178 kg)
Software compatible, inquire
with Koehler Customer Service.
132
0-124-138_6b_LOils_Layout 1 10/24/12 11:30 AM Page 133
Automated Cloud Point and Pour Point of Petroleum Products
Test Method
For Petroleum Products, cloud point and pour point of a petroleum product
is an index of the lowest temperature of its utility for certain applications.
The specimen is cooled at a specified rate and examined periodically. The
highest temperature at which a cloud is first observed at the bottom of the test
jar is recorded as the cloud point. The lowest temperature at which movement
of the specimen is observed is recorded as the pour point.
Automatic Cloud Point and Pour Point Analyzer with
Integrated Panel PC
• Cloud Point Analyzer conforms to ASTM D2500, D5771, D5772, D5773
and related test methods
• Pour Point Analyzer conforms to ASTM D97, D5853, D5950 and related
test methods
• Stand alone system with Integrated Touch Screen Panel PC
• Direct Cooling system eliminates the need for solvent cooling baths
• One-stage cooling system provides temperatures as low as -45°C and
a two-stage cooling system down to -80°C
• Cloud Point measured by light pulsed emission on I.R spectrum
through a coaxial fiber optic
• Pour Point measured by two PT100 detection probes placed on the
surface of the product and a mechanical moving arm bringing the test
jar to a horizontal position
KLA-3-TS
Automatic Cloud & Pour Point
Analyzer with Touch Screen
of rapid cooling, approaching -80°C bath temperatures in approximately 15
minutes, and utilizes less electricity than standard cooling systems. The
rapid cooling feature combined with a consistent cooling profile system
provides repeatable results with high test reproducibility.
Cloud Point Detection–The cloud point detection system provides automated
sample testing with the accuracy and repeatability in accordance with ASTM
D2500, D5771, D5772, D5773 and related international test methods. The
sophisticated dynamic measuring system emits a light pulse every 1°C from a
coaxial fiber optic cable positioned above the test sample. The light pulse is then
reflected off the silver bottom test jar to an optical sensor. The advanced software
package analyzes the response of the light pulse. The initial appearance of
crystallization is monitored by light scattering, signifying the cloud point of the
sample. All clear and transparent oils are readily measured by the detection
system, regardless of sample color.
Pour Point Detection–The pour point detection system provides automated
sample testing with the accuracy and repeatability in accordance with ASTM D97,
D5853, D5950 and related international test methods. The automated operation
involves removing the sample from the cooling jacket at 3°C intervals and tilting
it to a 90° angle as prescribed by the test method until no flow is observed.
Contact of the cold sample with the two PT100 detection probes positioned just
above the surface liquid level when the test jar is tilted identifies sample flow. The
test jar is automatically returned to the cooling jacket and sampled again until no
flow is detected for 5 seconds. The pour point result is then reported at 3°C
higher than the temperature at which the sample ceased to flow in accordance
with the test method.
Multiple Configuration System–These automated sample cooling and
physical property measurement systems can be configured with one, two,
three, four and six test positions with one of five possible analytical heads at
each position: cloud point, pour point, cloud & pour point, cold filter
plugging point and freezing point. Standard and customized multiple
configuration systems are readily available.
Specifications
Conforms to the specifications of:
KLA-1-TS: ASTM D2500, D5771,
D5772, D5773; DIN 51597; IP 219,
IP 444, IP 445, IP 446; ISO 3015
KLA-2-TS: ASTM D97, D5853,
D5950; IP 15, IP441; ISO 3016
KLA-3-TS: ASTM D97, D2500,
D5771, D5772, D5773, D5853,
D5950; DIN 51597; IP 15, IP 219,
IP441, IP 444, IP 445, IP 446;
ISO 3015, ISO 3016
Temperature Range:
One-Stage: +60°C to -45°C
Two-Stage: +60°C to -80°C
Dimensions WxDxH,in.(cm)
26 x 233⁄4 x 311⁄2 (66x60x80)
Net Weight: 176.5 lbs (80kg)
Ordering Information
Integrated Panel PC and Software Package–The Automated Cloud and Pour
Point Analyzers are complete standalone systems featuring an integrated panel
PC with an advanced software package. The 6.4” TFT/LCD touch screen display
has a resolution of 640x480 with a 262K color scheme. All analytical parameters
are graphed and displayed in real time as well as recorded in Microsoft® Excel
compatible file format. The software monitors the operation and performance of
all the analyzer components for proper data measurement, including the solenoid
valves, cooling system, pressure sensors, and the Platinum resistance PT100
Class A temperature probe.
Catalog No.
KLA-1-TS
KLA-1-TS/2
KLA-2-TS
KLA-2-TS/2
KLA-3-TS
KLA-3-TS/2
Cooling System–For various user applications, the automated cloud and pour
point systems are available with either one-stage cooling for temperatures as low
as -45°C or two-stage cooling for temperatures as low as -80°C. The direct
cooling system features integrated gas CFC free motors compressors thus
eliminating the need for a solvent cooling bath. The direct system is capable
KLA-PT100-CAL
KLA-DB-KIT
133
Resolution: 0.06°C
Accuracy: ±0.1°C
Repeatability / Reproducibility: as
per standard test methods or better
Data Storage: < 60,000 analyses
Electrical Requirements:
115V ± 15% / 60Hz
220V ± 15% / 50 to 60Hz
Auto Cloud Point Analyzer, Touch Screen (One-stage)
Auto Cloud Point Analyzer, Touch Screen (Two-stage)
Auto Pour Point Analyzer, Touch Screen (One-stage)
Auto Pour Point Analyzer, Touch Screen (Two-stage)
Auto Cloud & Pour Point Analyzer, Touch Screen (One-stage)
Auto Cloud & Pour Point Analyzer, Touch Screen (Two-stage)
Please specify voltage requirements when ordering.
Accessories
Calibration Decade Box - PT100 Simulator
Set of Connectors and Cables
Extended Cooling Range down to -100˚C Available Upon Request.
0-124-138_6b_LOilsAA2_Layout 1 11/30/12 12:00 PM Page 134
Dielectric Breakdown Voltage of Insulating Oils
Test Method
The majority of high-voltage transformers, cables, switchgears,
transducers, capacitors, and rectifiers use insulating oils for insulating
electrically live parts and to carry off thermal energy. The quality of
the insulating oil must be checked at regular intervals to ensure a
long equipment service life. The most important requirement of an
insulating oil is a high dielectric strength. Determination of the
dielectric breakdown voltage of insulating oils provides an early
detection method for any reduction in the insulating properties.
Automatic Portable Dielectric Breakdown Tester
•
•
•
•
•
•
•
•
•
Conforms to ASTM D877, D1816 and related test specifications
Output voltage: 75kV
Features 2.8” ultra bright color display for optimal readability and mobility
Built-in printer offers direct evaluation and reporting of results
Internal battery, external 12V power supply
Automatic Vernier function for electrode gap spacing
Measurement of Silicone based oils
Internal temperature measurement of oil sample
Bluetooth PC Connectivity and USB Flashdrive Capability
Specifications
Conforms to the specifications of:
ASTM D877, D1816; BS EN 60156; CEI EN 60156; IEC 156; VDE 0370 Pt. 5
Output Voltage: Up to 75kV rms symmetrical
Voltage measurement accuracy: 0 - 75kV ±1kV
Voltage slew rate: 0.5 - 10kV/s
Resolution (displayed): 0.1kV
Power Supply: 85V - 264V, 47Hz - 63Hz, 12V external supply
Power consumption: 60VA
Internal rechargeable battery: 1 x 12V / 7.2Ah
Switch-off time on flashover: < 5µs
Measurement of oil temperature: 0 - 100°C / 32 - 212°F
Temperature Resolution: 1°C / 1.8°F
Display: 2.8” color (ultra bright)
Selectable Programs: ASTM D1816-04-1mm, ASTM D1816-04-2mm,
ASTM D877-02A, ASTM D877-02B, IEC 156/95
Customer-specific programs: Unlimited
PC Software: Included
Printer: Dot Matrix Hard Copy Output
Interface: Bluetooth
USB: USB memory stick
Operating Temperature: -5°C - 45°C (23°F - 113°F)
Storage Temperature: -20°C - 60°C (-4°F
K16175 Automatic Portable Dielectric Tester
Dimensions WxHxD,in.(cm)
16.9x11x9.85 (43x28x25)
Net Weight: 48.5 lbs (22kg)
Shipping Information
Shipping Weight: 54.5 lbs (24.7kg)
Dimensions: 25x21x19in. (63.5x53.4x48.3cm)
Included Accessories
Calibration Sheet
User Manual
AC Power Cable
PC Software
Integrated Battery
Integrated Printer
134
Ordering Information
Catalog No.
K16175
Automatic Dielectric Breakdown Tester, 0-75kVAC,
100-240V 50/60Hz
Accessories
K16175-4
K16175-5
K16175-6
K16175-23
K16175-24
K16175-12
K16175-13
K16175-14
Transport Case
Test Vessel complete with electrodes for ASTM D1816
Test Vessel complete with electrodes for ASTM D877
IEC156 Test Cell with VDE Electrode
IEC156 Test Cell with Sphere Electrode
Spacer Gauge, 1mm
Spacer Gauge, 2mm
Spacer Gauge, 2.5mm
0-124-138_6b_LOils_Layout 1 10/24/12 11:30 AM Page 135
Coking Tendency of Oil
K50100 Panel Coker
Test Method
Determines the tendency of finished oils to form coke when in contact
with surfaces at elevated temperatures for short periods. A sample of oil
is mechanically splashed against an aluminum test panel at elevated
temperature. After a specified test period, the amount of coke deposited on
the panel is determined by weight.
Panel Coking Test Apparatus
• Conforms to FTM 791-3462 specifications
• Suitable as a screening test prior to performing engine tests
Digitally controlled panel coking apparatus for finished lubricating oils,
consisting of mechanical splasher, splash chamber and sample oil reservoir
Test panel temperature and oil sump temperature are individually controlled by
separate heaters with digital-indicating controllers. Mechanical splasher has a
variable speed 0-1800rpm drive motor with digital indicating control. A high
accuracy variable area flowmeter permits introduction of a corrosive acidic
atmosphere to increase the severity of the test. Equipped with a digital
countdown timer. Hinged safety cover has a port for fume removal and a
safety interlock switch that interrupts power to the drive motor when the
cover is lifted.
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
FTM 791-3462
Maximum Temperature:
Test Panel: 400°C (752°F)
Sample Oil: 210°C (410°F)
Temperature Control: Separate
controls for test panel and oil
temperature, with digital °C/°F
digital setpoint and display
Splashing Rate: 0-1800rpm,
with digital display
Timer: 0-99.9 hr variable countdown
Flowmeter Range: 0.2-1.0L/hr
Oil Reservoir Capacity: 0.35 liter
Electrical Requirements:
115V 60Hz, 8A
220-240V 50/60Hz, 5A
Test Unit: 32x18x21 (81x46x53)
Control Cabinet:
18x12x18 (46x30x46)
Net Weight:
Test Unit: 50 lbs (22.7kg)
Control Cabinet: 25 lbs (11.3kg)
Ordering Information
Catalog No.
K50100
K50110
K50119
K50190
Order Qty
Panel Coking Test Apparatus,
115V 60Hz
Panel Coking Test Apparatus,
with cyclic timer 115V 60Hz
Panel Coking Test Apparatus,
with cyclic timer 220-240V 50/60Hz
Panel Coking Test Apparatus,
220-240V 50/60Hz
Accessories
K50101
K50102
Aluminum Test Panel
Stainless Steel Test Panel (Type 321)
1
1
135
Shipping Information
Shipping Weight: 135 lbs (61.2kg)
Dimensions: 26.7 Cu. ft.
Digital Flowmeter option
is available for this unit.
≥
Software compatible, inquire
with Koehler Customer Service.
0-124-138_6b_LOilsAA_Layout 1 11/29/12 7:06 PM Page 136
Evaporation Loss of Lubricating Oils by the Noack Method
Test Method
For determining the evaporation loss of lubricating oils, particularly engine
oils. High temperatures can evaporate oil which may contribute to oil
consumption in an engine and can lead to a change in the properties of an
oil. A measured quantity of sample is placed in an evaporation crucible that
is then heated to 245.2°C with a constant flow of air drawn through it for 60
minutes. The loss in mass of the oil is determined.
Automatic Non-Woods Metal Noack Evaporative
Apparatus
K44100 Automatic Non-Woods Metal Noack Evaporative Apparatus
Included Accessories
Dimensions lxwxh,in.(cm)
Integrated Touch Screen Panel PC
Integrated Vacuum Pump
Inlet Filter
Evaporation Crucible
Test Ball (10)
Nozzle Cleaner
Crucible Holder
Protective Gloves
Hook Wrench
Pliers
15.75x17.72x17.72 (40x45x45)
Net Weight: 48.5 lbs (22 kg)
Ordering Information
Catalog No.
K44100
K44190
K44100-2
K44100-3
KLA-DB-KIT
KLA-PT100-CAL
Conforms to ASTM D5800, Procedure B
6.5” Integrated Touch Screen Panel PC
Integrated Vacuum Pump with automatic electronic control system
Direct sample temperature measurement via PT100 probe
Equipped with high resistant Kalrez valve, inlet filter to remove
product residuals
• USB port for connection to an external printer and/or external PC
• Storage capacity for more then 60,000 analysis
• CE Marked
The Automatic Non-Woods Metal Noack Evaporative Apparatus tests for the
evaporation loss tendencies of lubricating oils at temperatures of up to 275°C.
The newly designed electrically heated aluminum block allows for testing
without the use of hazardous Woods Metal. The Noack tester is equipped with
an Electronic regulator allowing for automatic control of temperature and
differential pressure. The system is managed by an integrated 6.5” Touch
Screen Panel PC by means of the Noack Evaluation Software run by a
Windows® based operating system. The Evaluation Software is capable of
recording all analytical parameters, allowing for user customizable parameters,
methods and result reports as well as printing graphs and test results.
Specifications
Automatic Non-Woods Metal Noack
Evaporative Apparatus 115V 60Hz
Automatic Non-Woods Metal Noack
Evaporative Apparatus 220V 50/60Hz
Accessories
K44100-SFW
K44100-1
•
•
•
•
•
Noack Evaluation Software
Glassware Accessory Set
Includes: 2L Glass Bottle (2), Rubber Stopper (4),
Glass Delivery Tubes, Silicon Connection Tubing
Stand for Glass Bottles with Inclined Manometer,
0-50mm H2O
Noack Reference Oil, 1 Liter
Set of Calibration Connectors and Cables
Calibration Decade Box – PT100 Simulator
Conforms to the specifications of:
ASTM D5800 Procedure B; IP 421; DIN 51581
Capacity: 1 Sample
Temperature Range: 225°C to 275°C
Temperature Resolution: 0.01°C
Temperature Accuracy: ±0.2°C
Repeatability/Reproducibility: Meets or Exceeds ASTM D5800
Ambient Temperature: Max. 35°C
Relative Humidity: Max 80%
Heater Power: 420W
Electrical Requirements:
115V 60Hz
220V 50/60Hz
136
0-124-138_6b_LOils_Layout 1 10/24/12 11:30 AM Page 137
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Foaming Characteristics of Lubricating Oils................Pages 108-110
ASTM D892; IP 146; DIN 51566; FTM 791-3211, 791-3213
Air Supply
Acetone
Desiccant
Toluene
Isopropanol
Cotton
Water Separability of Petroleum Oils
and Synthetic Fluids................................................................Page 111
ASTM D1401; ISO 6614; DIN 51599; FTM 791-3201
Precipitation Naphtha
Nochromix
Cotton
Acetone
Distilled Water
Demulsibility Characteristics of Lubricating Oils.................Page 112
ASTM D2711 and DIN 51353
Centrifuge
Distilled Water
Centrifuge Tubes
1,1,1-Trichloroethane
Oxidation Stability of Steam Turbine Oils and
Inhibited Mineral Insulating Oils by Rotating Bomb......Pages 114-118
ASTM D2112, D2272; IP 229
Liquid Detergent
Potassium Hydroxide
Acetone
Chloroform
Oxygen
Petroleum Spirit
Hydrochloric Acid
Isopropanol
Oxidation Stability of Gasoline Automotive Engine Oils
by Thin-Film Oxidation Uptake (TFOUT).......................Pages 114-118
ASTM D4742
Liquid Detergent
n-Hexane
Potassium Hydroxide
Isopropanol
Acetone
Oxygen
Air Supply
Water
Sludging Tendencies of Inhibited Mineral Oils............Pages 119-122
ASTM D4310
Syringe, 50mL
Acetone
n-Heptane
Chromic Acid
Filter Holder
Separatory Funnel
Forceps
Nitrogen
Desiccant Bags
Isopropanol
Flexible Tubing
Detergent
Hydrochloric Acid
Oxygen
Membrane Filters
Weighing Bottle, 60mL
Drying Oven
Vacuum Source
Flushing Tube
Rubber Policeman
Oxidation Characteristics of Extreme Pressure
Lubricating Oils...............................................................Pages 119-122
ASTM D2893
Drying Tower
Chromic Acid or equivalent detergent cleaning solution
Air Supply
Oxidation Stability of Mineral Insulating Oils ......................Page 123
ASTM D2440
n-Heptane
Potassium Hydroxide Solution
Isopropyl Alcohol
Acid Free Filter Paper
Oxygen
Toluene
Chloroform
p-Naphtolbenzein Indicator
Oxidation Stability of Inhibited Mineral Turbine Oils ..........Page 126
IP 280
Oxygen
Phenolphthalein
Hydrochloric Acid
Toluene
Ethanol
Membrane Filters
Burette
Filtration Apparatus
Alkali Blue Indicator
Heptane
Potassium Hydroxide
Dichloromethane
Sulfuric Acid
Evaporating Dish
Air Oven
Conical Flask, 500mL
Oxidation Stability of Distillate Fuel Oil
(Accelerated Method).....................................................Pages 119-122
Oxidation Stability of Straight Mineral Oil............................Page 126
ASTM D2274
IP 306
Drying Oven
Membrane Filters
Hot Plate
Oxygen
Acetone
Toluene
Filter Assembly
Beaker, 200mL
Isooctane
Water Supply
Methanol
Oxidation Characteristics of Inhibited Mineral Oils.......Pages 119-122
ASTM D943; DIN 51587
Desiccant Bags
Abrasive Cloth
Distilled Water
Detergent
Hydrochloric Acid
Oxygen
Gloves
Acetone
Glass Syringes, 10 and 50mL
Flexible Tubing
n-Heptane
Isopropanol
Nitrogen
Filtering Crucibles
Burette
Alkali Blue Indicator
n-Heptane
Potassium Hydroxide
Chloroform
Sulfuric Acid
Membrane Filters
Petri Dishes
Oven
137
Porcelain Crucibles
Oxygen
Phenolphthalein
Hydrochloric Acid
Toluene
Ethanol
Acetone
Forceps
Filtration Apparatus
Isopropanol
0-124-138_6b_LOils_Layout 1 10/24/12 11:30 AM Page 138
Additional Accessories
Oxidation Stability of Mineral Insulating Oil ........................Page 126
IP307
Filtering Crucibles
Burette
Alkali Blue Indicator
Heptane
Potassium Hydroxide
Chloroform
Sulfuric Acid
Isopropanol
Forceps
Filtration Apparatus
Porcelain Crucibles
Oxygen
Phenolphthalein
Hydrochloric Acid
Toluene
Ethanol
Acetone
Membrane Filters
Petri Dishes
Oven
Oxidation Stability of Inhibited Mineral Insulating Oils ......Page 126
IP 335
Porcelain Crucibles
Oxygen
Phenolphthalein Solution
Hydrochloric Acid
Toluene
Ethanol
Forceps
Filtration Apparatus
Sulfuric Acid
Isopropanol
Burette
Alkali Blue Indicator
n-Heptane
Potassium Hydroxide
Chloroform
Membrane Filters, 5.0 µm
Petri Dishes
Oven
Acetone
ASTM 5704; STP12A L-60-1 Performance Test (formerly CRC L-60 Test);
FTM 791B Method 2504
Pentane
Toluene
Air Supply
Tweezers
Organic Cleaning Solvent
Corrosiveness and Oxidation Stability of Hydraulic Oils,
Aircraft Turbine Engine Lubricants
and Other Highly Refined Oils.......................................Pages 124-125
ASTM D4636; FTM 791-5307, FTM 791-5308; IHC BT-10, DIN 51394
Air Supply
Analytical Balance
Centrifuge and Tubes
Microscope
Oven (optional)
Forceps
Sodium Dichromate
Brush
Nochromix
Rust Preventing Characteristics of Inhibited Mineral Oil
in the Presence of Water
(Standard and Horizontal Disc Methods) .....................Pages 128-129
ASTM D665, D3603; NACE TM-01-72; IP 135; ISO 7120; DIN 51355,
DIN 51585; FTM 791-4011, 791-5315
Oven
Isooctane
Distilled Water
Petroleum Spirit 60/80
Naphtha
Synthetic Sea Water
Precipitation Naphtha
Corrosion of Lead by Lubricating Oils...................................Page 130
FTM 791-5321.1
Air Supply
Forceps
Acetone
Cotton
Analytical Balance
Petroleum Naphtha
Steel Wool
Bearing Compatibility of Turbine Oils ...................................Page 131
FTM 791-3452
Test Equipment for:
ASTM D445 Kinematic Viscosity (refer to Viscosity Section)
ASTM D524 Ramsbottom Carbon Residue (refer to Page 53)
ASTM D974 Total Acid Number
Copper Corrosion From Petroleum Products........................Page 131
ASTM D130
Thermal Oxidation Stability of Automotive
Gear Lubricants .......................................................................Page 127
Oakite 811
Stoddard Solvent
Reference Oils
Absorbent Cotton
Heptane
(Continued)
Cotton
n-Heptane
Acetone
Nitric Acid
Sodium Hydroxide
Sodium Phosphate
Sulfuric Acid
Distilled Water
Filter Paper
Isooctane
Stoddard Solvents
Cotton Wool
Stainless Steel Forceps
Cloud Point and Pour Point of Petroleum Oils.............Pages 132-133
ASTM D97, D2500; IP 15, 219; ISO 3015, 3016; DIN 51597; FTM 791-201
Methanol
Solid Carbon Dioxide
Calcium Chloride
Ethanol
Sodium Sulfate
Petroleum Naphtha
Acetone
Sodium Chloride
Coking Tendency of Oil ...........................................................Page 135
FTM 791-3462
Emery Paper
Petroleum Ether
Evaporation Loss of Lubricating Oils (Noack Test) ..............Page 136
ASTM D5800; DIN 51581; IP 421
Balance
Toluene
138
Naphtha
0-139-146_7_Tribology_Layout 1 10/24/12 11:32 AM Page 139
Tribology
Test Methods
Page
Test Methods
Page
Tribology (Friction and Wear) Testing of Lubricants
Friction and Wear Test Equipment
Slurry Abrasion Tester
ASTM G105 ..........................................................................................146
Four Ball Wear and EP
ASTM D2266, D2596, D2783, D2793, D4172, D5183,
IP 239, IP 300........................................................................................140
Air Jet Erosion Tester
ASTM G76..............................................................................................146
Measurement and Data Acquisition System
TriboDATA Tribology Software ..............................................................141
High Frequency Reciprocating Rig (HFRR)
ASTM D6079; ISO 12156 ....................................................................141
Dry Abrasion Tester
ASTM G65..............................................................................................146
Universal Wear
ASTM G77, G99 ....................................................................................146
Pin-On-Disc Machine
ASTM G99 ............................................................................................142
Shear Stability
ASTM D6278 ........................................................................................146
Timken
ASTM D2509, D2782 ............................................................................143
Tapping Torque Tester
ASTM D5619 ........................................................................................146
Corrosion Inhibition Properties of Greases
IP 220; ISO 11007; DIN 51802; NFT 60-135; SIS 15513....................144
Grease Life Tester
ASTM D3336..........................................................................................146
Scratch Tester ......................................................................................144
Pin and Vee Block Tester
ASTM D2670, D3233 ............................................................................145
BOCLE
ASTM D5001..........................................................................................145
Multispecimen Tester
ASTM D2266, D3702, D4172 ..............................................................146
Vane Pump Wear
ASTM D2882..........................................................................................146
Bearing and Graeses Noise Characteristics ......................................146
Mechanical Stability of Greases ........................................................146
Lubricating Ability of Greases ............................................................146
Mechanical and Dynamic Behavior of Greases ................................146
www.koehlerinstrument.com
0-139-146_7_TribologyAA_Layout 1 11/29/12 7:10 PM Page 140
Four Ball Wear and EP
Tribology (Friction and Wear) Testing of Lubricants
Friction and Wear Test Equipment
Koehler Instrument Company is pleased to offer advanced equipment
for a variety of friction and wear tests. Several of the standard
instruments that we offer are listed here. Please contact us to discuss
your requirements for these as well as custom-designed units for
tribology analysis methods. Our applications personnel will consult with
you on your requirements and work with our design staff to provide
solutions for your tribology testing needs.
Test Method
Determines the Wear Preventative (WP) and Extreme Pressure (EP)
characteristics of lubricating oils and greases in sliding steel-on-steel
applications. The test consists of rotating a steel ball under load against
three stationary steel balls coated with lubricant. Measurements are taken
at the rotating speeds, temperatures, and duration as specified by
published standards. The load-wear index can be calculated from the weld
point in EP tests, and lubricant comparisons can be made based upon scar
diameters incurred from wear tests.
Four Ball Wear and EP Tester
K93100 Four Ball Tester
Shipping Information
Shipping Weight: 1360 lbs (620 kg)
Dimensions: 45 Cu. ft.
*Pneumatic option required
IP300 or CEC-L-45-A-99 units available.
Please contact Koehler Customer Service for additional information.
• Conforms to ASTM D2266, D2596, IP 239, and related specifications
• Performs Wear Preventative (WP) and Extreme Pressure (EP) tests
• Displays and records normal load, frictional torque, time, and temperature
• Test speeds and temperatures are electronically controlled
• Data Acquisition Software and Card are included
• Custom configurations are available
• Precise variable loading capability*
Four Ball Tester performs both Wear Preventative (WP) and Extreme Pressure
(EP) analyses for measuring the wear and frictional properties of lubricants
under sliding steel-on-steel test conditions. Tests are performed in accordance
to the latest ASTM and IP published methods. Normal load on the ball
assembly and frictional torque are measured through load cells. Data is
processed and stored utilizing TriboDATA, an advanced data acquisition and
processing software package. Test results can be plotted and compared,
as well as exported to other programs. Wear scars on the steel balls are
measured and recorded with a High Resolution Digital Microscope available as
recommended accessory for the Four Ball Tester.
High Resolution Digital Microscope
Included Accessories
Set of Weights
Ball Chucks
Ball Pot
Ball Chuck Remover
Ball Rack
Ball Clamp Ring
Ball Holder Base Disc
Set of Hand Tools
Torque Wrench
Electrical Controller
Connecting Cables
TriboDATA Software
Calibration and Test Reports
Koehler's Four Ball Microscope is a versatile device for measuring the wear
scar diameter on a steel test ball. This apparatus consists of the “Dinolite”
Microscope with “DinoCapture” Software mounted at an angle on an
aluminum base. The device is designed to measure the wear scar without
removing the test balls from the ball pot allowing for a safer measurement
procedure. The wear scar can be viewed through an external PC. The software
measures the wear scar using a diameter and line tool. The images can be
saved at varied resolutions on a PC.
Specifications
Ordering Information
Catalog No.
K93100
K93100-PN
K93190
K93190-PN
Order Qty
Four Ball Tester, 220V 60Hz
1
Four Ball Tester with pneumatic loading, 220V 60Hz
Four Ball Tester, 380V 50Hz
1
Four Ball Tester with pneumatic loading, 380V 50Hz
K93105
K93111
Test Balls (Pack of 100)
High Resolution Digital Microscope
Accessories
Conforms to the specifications of:
ASTM D2266, D2596, D2783, D4172, D5183*, IP 239
Electrical Requirements:
220V, 60Hz, 3 phase
440V, 50Hz, 3 phase
Drive Motor: 1.5 kW
Test Speeds: 1200, 1440, 1760 rpm
Optional Test Speeds (min/max): 1000/3000, 300/3000 rpm
Maximum Axial Load: 10000 N at 3000 rpm or 12000 N at 1800 rpm
Test Duration (min/max): 1/9999 min
Test Ball diameter: 12.7 mm
140
0-139-146_7_Tribology_Layout 1 10/24/12 11:33 AM Page 141
Tribology Data Acquisition System
TriboDATA Data Acquisition System
• Powerful data acquisition system provides analog to digital conversion
and data analysis of test results for many tribology instruments available
from Koehler as well as other tribology instrument manufacturers
• Real-time display of critical test parameters such as normal load, friction
force, temperature, and time
The Koehler TriboDATA System is designed to acquire and process analog data
from the various tribology test instrumentation offered from Koehler as well
as from other tribology instrument manufacturers. The analog-to-digital
converter card is comprised of four analog inputs, and the test data is
recorded and displayed in real-time. Up to four graphs can be displayed
simultaneously. The data can be stored to disk for future reference or exported
in an ASCII text format to other software packages. Critical test parameters are
also saved with the data. With the TriboDATA hardware and software package,
data acquisition of crucial test parameters such as normal load, friction load,
temperature, and time can be seamlessly performed to ensure that your test
results are consistent and repeatable within prescribed test conditions. As an
option, a CCD camera package is available to capture wear scar images and
store them on a PC for analysis.
Computer Requirements
Included Accessories
Processor: Pentium or higher
Processor Speed: 100 MHz or higher
Operating System: Windows® 95/98/NT
Memory (RAM): 16 Mb
Required Disk Space: 10 Mb
One Free Expansion ISA Slot
Software on CD
Acquisition Data Card
Connection Cable
Instruction Manual
K93900 TriboDATA Data Acquisition System
Ordering Information
Catalog No.
K93900
TriboDATA Data Acquisition System
High Frequency Reciprocating Rig
Test Method
A 2-mL test specimen of fuel is placed in the test reservoir and maintained
at 25 or 60°C. When the temperature has stabilized, a vibrator arm
holding a nonrotating steel ball and loaded with a 200-g mass is lowered
until it contacts a test disk completely submerged in the fuel. The ball is
caused to rub against the disk with a 1-mm stroke at a frequency of 50 Hz
for 75 min. The ball is removed from the vibrator arm and cleaned. The
dimensions of the major and minor axes of the wear scar are measured
under magnification and recorded.
High Frequency Reciprocating Rig
The two-station Fuel Lubricity Wear Test Machine incorporates two test
positions with heater pads and mounting arrangements for fuel lubricity test
specimens. Load is applied manually by means of dead weights directly to the
fixed ball specimen carrier by means of a loading yoke. Machine controls are
limited to speed control of the drive motor to give the required frequency,
temperature control of the specimen bath and test duration. Test data is
limited to post test wear scar measurement only and no facilities are provided
for friction force measurement.
Electrical Requirements
115V 60Hz, Single Phase
230V 50/60Hz, Single Phase
Ordering Information
Catalog No.
K93450
K93459
High Frequency Reciprocating Rig, 115V 60Hz
High Frequency Reciprocating Rig, 230V 50/60Hz
K93450 High Frequency
Reciprocating Rig (HFRR)
Specifications
Test specifications: ASTM D6079; ISO 12156
Contact Geometry: Ball on Plate
Ball Specimen: 6 or 10 mm diameter
Load: 1.95 to 10.00 N (± 0.01 N)
Stroke: 1 mm (± 0.02 mm)
Frequency: 2.5 to 50 Hz (± 1 Hz)
Fluid Volume: 2 mL (± 0.2 mL)
Test Temperature: 25 or 60°C (± 2°C)
Test Duration: 75 min (± 0.1 min)
Bath Surface Area: 6 cm2
141
Order Qty
1
0-139-146_7_TribologyAA_Layout 1 11/29/12 7:10 PM Page 142
Pin-On-Disc
K93500 Pin-On-Disc Tester
Specifications for Pin-On-Disc
with Environmental Chamber &
Lubricant Recirculating System
Temperature: 60°C Maximum
Discharge Rate: 0-1 L/min
Viscosity Range: 90 SAE Maximum
Capacity: 3L of Lubricant
Shipping Information
Shipping Weight: 440 lbs (200 kg)
Dimensions: 18 Cu. ft.
Included Accessories
Electrical Controller Unit
Connecting Cables
Spare Fuses
TriboDATA Software
Set of Weights
Set of Hand Tools
Set of Pins
Calibration and Test Reports
Electrical Requirements
115V 60Hz
230V 50/60Hz
Ordering Information
Catalog No.
K93500
K93590
Pin-On-Disc Machine, 115V 60Hz
Pin-On-Disc Machine, 230V 50Hz
Order Qty
1
Optional Configurations Available
Environmental Chamber
Lubricant Recirculating System
Environmental Chamber and
Lubricant Recirculating System
High temperature models (up to 700°C) are available. Please contact
Koehler Customer Service for additional information.
Pin-On-Disc Tester
• Conforms to ASTM G99 standard test method
• Analyzes wear and friction characteristics of sliding contacts
(dry or lubricated conditions)
• Tests can be performed on a variety of materials: metals, polymers,
composites, ceramics, lubricants, cutting fluids, abrasive slurries,
coatings, and heat-treated samples
• TriboDATA software package varies and records pin pressure, pin
temperature, sliding speed, and lubrication parameters
• Custom configurations available
The Pin-On-Disc machine is a versatile unit designed to evaluate the wear and
friction characteristics on a variety of materials exposed to sliding contacts in
dry or lubricated environments. The sliding friction test occurs between a
stationary pin stylus and a rotating disk. Normal load, rotational speed, and
wear track diameter can be varied. Electronic sensors monitor wear and
the tangential force of friction as a function of load, speed, lubrication, or
environmental condition. These parameters as well as the acoustic emissions
at the contact are measured and displayed graphically utilizing the TriboDATA
software package.
Specifications
Conforms to the specifications of: ASTM G99
Sliding Speed Range:
0.26-10 m/sec
Disc Rotation Speed:
100-2000 rpm
Maximum Normal Load:
200 N
Frictional Force:
0-200 N
Wear Measurement Range: 4 mm
Pin Size:
3-12 mm diagonal/diameter
Disc Size:
160 mm diameter x 8 mm thick
Wear Track Diameter:
10-140 mm
142
0-139-146_7_Tribology_Layout 1 10/24/12 11:33 AM Page 143
Timken Testers
Timken Mechanical Tester
A steel test cup rotating at 800 RPM is pressed against a steel test block.
Sample under test is carried by the test cup into the sliding contact. Test load at
the contact is progressively increased, score value and OK value are determined.
Test Method
This tester is used to measure extreme pressure properties of lubricating
grease and lubricating fluids.
Specifications
Conforms to the specifications of:
ASTM D 2509 - IP 326 for greases.
ASTM D 2782 - IP 240 for lubricating fluids.
Rate of loading : 0.9 to 1.3 Kg/sec.
Grease feed rate : 45 ± 9 g / min.
Fluid feeder : 3.8 liter with recirculating pump and heater.
Motor : 1.5 kW with variable frequency drive.
Power : 220V 60Hz, 380V 50Hz, 5 KVA max.
Included Accessories
•
•
•
•
Calibration kit for load and RPM
Set of tools for operation
Microscope for scar measurement
Electronic timer
Timken Pneumatic Tester
A steel test cup rotating at 800 RPM is pressed against a steel test block. Sample
under test is carried by the test cup into the sliding contact. Test load at the
contact is progressively increased, score value and OK value are determined.
K92000 Timkin Tester
Test Method
This tester is used to measure extreme pressure properties of lubricating
grease and lubricating fluids.
Ordering Information
Catalog No.
K92000
K92000-PN
K92090
K92090-PN
Features & Benefits
• Loading is pneumatic. Frictional torque is measured with a torque cell.
Specifications
Conforms to the specifications of:
ASTM D 2509 - IP 326 for greases.
ASTM D 2782 - IP 240 for lubricating fluids.
Rate of loading : 0.9 to 1.3 Kg/sec.
Grease feed rate : 45 ± 9 g / min.
Fluid feeder : 3.8 liter with recirculating pump and heater.
Motor : 1.5 kW with variable frequency drive.
Power : 220V 60Hz, 380V 50Hz, 5 KVA max.
Included Accessories
• Calibration kit for load and RPM
• Vibration sensor
• Microscope for scar measurement
• Set of tools for operation
• Electronic timer
143
Timken Tester, 220V 60Hz
Timken Tester with pneumatic loading, 220V 60Hz
Timken Tester, 380V 50Hz
Timken Tester with pneumatic loading, 380V 50Hz
0-139-146_7_Tribology_Layout 1 10/24/12 11:33 AM Page 144
Corrosion Inhibition Properties of Greases
Test Method
Measures the ability of a grease to protect a bearing against corrosion in
the presence of water. Two sets of grease-coated bearings per station are
partially immersed in water and rotated at a speed of 80 rpm in a sequence
of running and resting periods. At the end of the test, the raceways of the
bearing outer rings are inspected for rust.
Emcor Grease Testing Machine
• Evaluates the rust preventive properties of greases and oils
• Performs both standing and dynamic testing
The Emcor Grease Testing Machine evaluates the rust preventive properties of
greases on bearing components, measuring the ability of a grease to protect a
bearing against corrosion in the presence of water. As bearings are normally
used in environments exposed to humidity and temperature variations,
condensation may form on the bearing thus promoting the onset of rust. Rust
is detrimental to proper bearing operation and will compromise the longevity
of the bearing. A good quality grease should be designed to protect the
bearing from rust and corrosion under these conditions.
K94400 Emcor
Ordering Information
Catalog No.
K94400
K94490
Emcor Grease Testing Machine, 115V 60Hz
Emcor Grease Testing Machine, 230V 50Hz
Order Qty
1
Accessories
K94401
K94402
K94403
K94408
K94410
K94490-1
Test Bearing
Mounting Sleeve
Mounting Nut
Mounting Tool
Filling Device for Test Bearings
Emcor Washout Test Option
Includes: Peristaltic Pump, Overflow Container,
Inlet and Outlet Tubing and Pipe Fittings
The Emcor system features test method versatility, since both greases and oils
can be tested as well as variations can be made with regard to the test medium
(e.g., brine instead of water). The costs for running these tests are minimal.
The two test bearings are the only machined parts that have to be renewed for
each test, and the polyamide material for the housing is rigid and strong and
rarely ever needs replacement.
8
8
8
1
1
1
Specifications
Dimensions lxwxh,in.(cm)
Conforms to the specifications of:
ASTM D6138; IP 220; ISO 11007;
DIN 51802; NFT 60-135;
SIS 155130
Electrical Requirements:
115V, 60Hz, 1 phase
230V, 50Hz, 1 phase
481⁄2x15x11 (123x38x28)
Net Weight: 88 lbs (40kg)
Shipping Information
Shipping Weight: 121 lbs (55 kg)
Dimensions: 8 Cu. ft.
Scratch Tester
Specifications
Scratch Tester
Normal load control range: 2 - 20N
Normal load accuracy: 1% or 10mN
Tangential force measurement range: 2 - 20N
Tangential force accuracy: 1% or 10mN
Stroke (X): 0.1 - 50mm
Speed: 0.1 - 5mm/s
Pitch(Y): 0.2 - 50mm
Loading Rate: 0 - 20N/s. In steps of 0,2,5,10,15,20N/s
Sample Size (LxWxT): 60x60x10mm
Operating Temperature: 15 - 40°C. RH: 25 - 85%
Storage Temperature: -10 - 40°C, RH: 0 - 90%
Electrical Requirements:
115V 60Hz
220V 50Hz
The Scratch Tester is a versatile instrument capable of quantifying scratch
resistance, critical load, adhesion and bond strength for a wide range of
surfaces. The tester evaluates scratch resistance of a sliding surface in relative
motion (X movement) to a stylus. The stylus is pressed against the moving
surface with controlled force which is normal to the surface. Tangential force at
the contact is measured. The ratio of tangential and normal forces is merely the
co-efficient of friction till the threshold of surface damage. Energy required to
damage the surface contributes an additional component to the tangential force,
which increase this ratio. Force ratio is not the only sign of damage - acoustic
emission level also increases corroborating the occurrence of surface damage.
Image of the entire scratch may be captured and the view at any given load can
be seen to study nature of failure.
Ordering Information
Included Accessories
Control Box
Reference Sample (2)
Tool Kit
Diamond Indenter
Data Acquisition Software
Operating and Instruction Manual
Catalog No.
K93000
K93090
Scratch Tester, 115V 60Hz
Scratch Tester, 220V 50Hz
K93004
K93016
CCD Based Image Acquisition System
Acoustic Emission Sensor
Accessories
Dimensions lxwxh,in.(cm)
11.81x10.83x21.65 (30x27.5x55)
Net Weight: 44.1lbs (20kg)
144
0-139-146_7_TribologyAA_Layout 1 11/29/12 7:10 PM Page 145
Pin and Vee Block Tester
Test Method
To evaluate wear preventative and load carrying properties of fluid
lubricants, and endurance (wear) life of film lubricants.
Pin and Vee Block Tester
•
•
•
•
•
Automatic Start of Test at Set Temperature
Over-Temperature and Over-Torque Protection
Maintenance of Test Speed within Specified Limits over entire Load Range
Calibration kit for Load, Torque, and Wear
High Performance Sensor to cover entire test load range with single load
cell with adequate resolution.
The Pin and Vee Block Tester consists of a rotating pin pressed between two
stationary steel Vee blocks. Load is applied to the Vee blocks by a ratchet
mechanism. Ramping of load during extreme pressure testing is made
possible by auto advancement mechanism of ratchet. Pin and Vee blocks are
immersed in lubricant fluid under test in heated test cup. Wear, torque and
endurance life is evaluated accordingly. The Pin and Vee Block tester comes
with data acquisition software. Test torque, load, temperature and wear are
measured and recorded. The software permits users to view, compare and
report various test results.
Specifications
K95190 Pin and Vee Block Tester
Included Accessories
Conforms to the Specifications of:
ASTM D2625, D2670, D3233, D5620;
FTM 791C-3807.1, FTM 791C-3812.1
Test Load: 0 to 4500 lbf
Torque: 0 to 100 in-lb
Speed: 100 to 500 RPM
Temperature: Ambient to 200°C
Duration: 0 to 999.9 minutes
Electrical Requirements:
230V, 50/60Hz, 2 KVA, 1 Phase
Calibration Kit
Data Acquisition Software
Brinell Ball Attachment
Test Pin (50)
Vee Block (100)
Measuring Microscope
Steel Ruler, 6”
Dust Cover
Shear Pin (50)
Ordering Information
Catalog No.
K95190
Pin and Vee Block Tester, 230V 50/60Hz
Measurement of Lubricity of Aviation Turbine Fuels
by the Ball-on-Cylinder Lubricity Evaluator (BOCLE)
Test Method
ATF Lubricity Test Rig (BOCLE)
Covers the Assessment of the wear aspects of the boundary lubrication
properties of aviation turbine fuels on rubbing steel surfaces.
The instrument consists of a rotating test ring against which a fixed test ball
is pressed with the required force. A fuel bath containing the fuel under
test is placed on – movable stage under the test ring. The temperature is
controlled and the air is conditioned.
Fuel under test is conditioned by maintaining the fuel temperature at 25°C
maintained at 25°C with 10% Relative Humidity is passed through the test
area which is enclosed.
After conditioning of the fuel, a test ball of 12.7 mm diameter is pressed
against the outer surface of the test ring. The lower part of the test ring is
immersed in the test fuel bath.
The test ball is pressed with a force of 10 N against the test ring. The test
ring is made to rotate at 240 RPM for a period of 30 minutes after which
the test stops.
The wear scar on the test ball is studied and the scar diameters of the wear
scar (major and minor axis) are measured.
Data Acquisition
Test parameters such as speed, test duration, fuel temperature, air
temperature and humidity are acquired, displayed and recorded. The
acquired data can be viewed in graphs. The data acquisition system
provides the users with the facility to super impose up to four test graphs
for comparative viewing.
Specifications
Conforms to the Specifications of: ASTM D5001
Motor Speed: 240 ± 0.5 RPM
Fuel Temperature Control: 25±1.0 max, 0.1°C typical
Flow Rate: 3.8 ± 0.1 L/min
Relative Humidity: 10.0 ± 0.2% indicated
Temperature: 25±1.0 max, 0.1°C typical
Fuel Conditioning: 15 min ± 0.1s
Test Duration: 30 min ± 0.1s
Ambient Temperature: 15 to 22°C
Electrical Requirements: 230V, 50Hz, 2 KVA, 1 Phase, 1.5 KVA Max.
Ordering Information
Catalog No.
K94190
145
ATF Lubricity Test Rig (BOCLE), 230V 50Hz
0-139-146_7_TribologyAA_Layout 1 11/29/12 7:10 PM Page 146
Multispecimen
Multispecimen Tester
Configurations Table
Ball on flat
1, 2, 3 balls can be used
Sliding point contact
Dry or lubricated contact
Cylinder on flat
1 or 2 pins.
Sliding line contact
Dry or lubricated
Pin on flat
1, 2 or 3 pins.
Sliding area contact
Dry or lubricated
Four ball wear
ASTM D2266
Wear preventive properties of lubricants
ASTM D4172
Thrust washer
ASTM D3702
Rotating washer against fixed washed with axial load
• Multiple test configuration for wear and friction monitoring in one unit
• Speeds variable to 2000 rpm and loads to 1000 N
• Data acquisition system records speed of rotation, normal load,
sample temperature, and frictional torque
Measures and displays a variety of friction and wear characteristics on various
geometric test samples with different compositions and forms. Test
configurations are easy to change on the instrument: single or multiple, sliding
or rolling, point, line or area contacts are available. A wide range of materials
including coatings, lubricants, plastics, metals, polymers, ceramics, and
composites can be readily analyzed. The test is performed by mounting a test
sample into the spindle and rotating it against a stationary counter-face test
specimen. The spindle rotation speed, normal load, and interface temperature
can be user-adjusted in accordance with published ASTM standards. Specimen
holders are designed for standard test configurations; optional custom
designed holders for customer specific applications are also available. This unit
has a temperature range to 120°C, load to 1000 N and speed up to 2000 rpm.
Windows®-based TriboDATA data acquisition software is included, and some of
the possible configurations are shown in the table to the right.
Specifications
Conforms to the specifications of:
ASTM D2266, D3702, D4172
Normal Load: 5-1000 N
Frictional Torque Measurement
Range: 0-10 Nm
Shaft Speed: 200-2000 rpm
Wear Measurement: 0-2000 µm
x
Non-Rotating Sample
Diameter/Diagonal: up to 80 mm
Pin Sample Diameter: up to 8 mm
Ball Diameter: 12.7 mm
Non-rotating Sample Temperature:
Ambient to 100°C
Ordering Information
Catalog No.
K93600
K93690
Multispecimen Tester, 220V 60Hz 3 Phase
Multispecimen Tester, 380V 50Hz 3 Phase
Order Qty
1
Included Accessories
Included Adapters
Electrical Controller
Electrical Cables
TriboDATA Software
Set of Hand Tools
Calibration and Test Reports
Ball on Flat
Cylinder on Flat
Pin on Flat
Four Ball Wear Preventative
Thrust Washer
Electrical Requirements
Shipping Information
220V 60Hz 3 Phase
380V 50Hz 3 Phase
Shipping Weight: 880 lbs (400 kg)
Dimensions: 32 Cu. ft.
Tribology Test Specimens and Other Tribology Equipment
Slurry Abrasion Tester
Measures the slurry abrasive resistance of solid materials as prescribed by
ASTM G105 specifications. Performs tests on metals, minerals, polymers,
composites, ceramics, coatings, and heat-processed materials. A rectangular
test sample is rotated in a slurry cup with the temperature maintained using a
water bath. The test speed, temperature, duration, sample size, and slurry
composition can be varied. The differential mass of the sample before and after
the test is converted to volume loss (abrasion index) for direct comparison of
the tested materials.
Tapping Torque Tester
Evaluates metal working fluids and various machining operations according
to ASTM D5619 for the the torque requirements of tapping operations in
pre-drilled samples. Software package acquires cutting torque and rotational
speed and displays them as a function of test duration or angle of tool rotation.
Air Jet Erosion Tester
Performs air jet erosion test according to ASTM G76 specifications. A test
sample is bombarded by a gas containing particulates with a known velocity
and concentration of particles. Comparison can be made by varying test
sample composition, size, particle velocity, angle of incidence, and temperature.
Custom-Built Tribology Test Equipment
and Test Specimens
Test specimens are available for all of the tribology instrumentation offered
from Koehler. Please inquire with customer service about other custom-built
tribology test equipment and test specimens.
Custom-designed equipment is readily available
for the following tribology test methods:
Universal Wear (ASTM G77, G99)
Vane Pump Wear (ASTM D2882)
Shear Stability (ASTM D6278)
Slurry Erosion Tester
Reichert Tester
Grease Life Tester (D3336)
Grease Noise Tester
V2F Grease Testing Machine
ROF Grease Testing Machine
(DIN 51806)
R2F Grease Testing Machine
Dry Abrasion Tester
Measures index of abrasive resistance to dry sand according to ASTM G65 test
specifications. Test specimen is held against a rotating wheel and abraded with
a grit of controlled size, composition, and flow with the proper test duration
and applied force as prescribed by the ASTM test method. The differential
mass of the specimen before and after the test is recorded and converted to
volume loss (abrasion index) for direct comparison of tested materials.
146
High Temperature
Air Jet Erosion
Tester
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 147
Lubricating Greases
Test Methods
Page
Test Methods
Page
Evaporation Loss of Lubricating Greases and Oils
ASTM D972, D2878; IP 183; FTM 791-351 ........................................148
Leakage Tendencies of Automotive Wheel Bearing Greases
ASTM D1263; FTM 791-3454 ..............................................................160
Evaporation Loss of Lubricating Grease Over Wide Temperature
Range ASTM D2595, D2878 ................................................................149
Life Performance of Automotive Wheel Bearing Greases
ASTM D3527, D4950 ............................................................................161
Dropping Point of Lubricating Greases
D566, D4950; IP 132; ISO 2176; DIN 51801; FTM 791-1421 ............150
Leakage Tendencies of Automotive Wheel Bearing Grease
Under Accelerated Conditions ASTM D4290, D4950 ........................161
Dropping Point of Lubricating Grease Over Wide Temperature Range
ASTM D2265, D4950 ............................................................................151
Water Washout Characteristics of Lubricating Greases
ASTM D1264, D4950; IP 215; FTM 791-3252 ....................................162
Oxidation Stability of Lubricating Grease by the Oxygen Bomb Method
ASTM D942; IP 142; DIN 51808; FTM 791-3453 ........................152-153
Resistance of Lubricating Grease to Water Spray ASTM D4049 ....163
Corrosion Preventive Properties of Lubricating Greases
ASTM D1743..........................................................................................154
Oil Separation From Lubricating Grease
ASTM D6184; FTM 791-321 ................................................................164
Oil Separation On Storage of Grease IP 121 ....................................164
Copper Corrosion From Lubricating Grease
ASTM D4048; FTM 791-5309 ..............................................................155
Oil Separation From Lubricating Grease During Storage
ASTM D1742; FTM 791-322 ................................................................165
Roll Stability of Lubricating Grease
ASTM D1831; MIL-G-10924SA ............................................................156
Estimation of Deleterious Particles in Lubricating Greases
ASTM D1404..........................................................................................166
Apparent Viscosity of Lubricating Greases ASTM D1092 ................157
Oil and Grease in Water and Wastewater by Infrared (IR)
ASTM D7066; EPA Methods 413.2 and 418.1 ....................................166
Grease Mobility U.S. Steel Method; ASTM Draft Method ..................158
Low Temperature Torque of Ball Bearing Grease
ASTM D1478, D4693, D4950; FTM 791-334 ......................................159
Low Temperature Torque of Grease-Lubricated Wheel Bearings
ASTM D1478, D4693, D4950; FTM 791-334 ......................................159
Lincoln Ventmeter ................................................................................167
For information on additional test methods for lubricating greases:
–Please refer to the Penetration Section
–Additional test methods are available upon request
–please call or write for information
www.koehlerinstrument.com
0-148-168_8_LubeGreasesAA2_Layout 1 11/29/12 7:20 PM Page 148
Evaporation Loss of Lubricating Greases and Oils
Test Method
Evaluates the potential for evaporation loss of lubricant components in
high temperature service. A controlled flow of heated air is passed over the
sample for a specified period. Evaporation loss is measured by the change
in sample weight during the test. The Evaporation Loss test can also be
used for Estimating Apparent Vapor Pressures and Molecular Weights of
Lubricating Oils (ASTM D2878). A high temperature version of the
Evaporation Loss test is available (See ASTM D2595).
Evaporation Loss Tester
• Conforms to ASTM D972, D2878 and related specifications
• Two-sample testing capability
Evaporation Cell–Suitable for evaporation loss tests on lubricating greases
and oils in the temperature range of 210 to 300°F (99 to 149°C). Passes
heated air over the sample at the required flow rate. Consists of stainless steel
body, cover, eduction tube and hood. Calibrated flowmeter with needle valve
maintains 2L/min. air flow at standard temperature and pressure. Supplied
with stainless steel grease or oil sample cup. Sample cups are interchangeable.
Entire assembly mounts in Evaporation Loss Test Bath.
K29500 Evaporation Test Cell with Grease Cup
Specifications
Conforms to the specifications of:
ASTM D972, D2878; IP 183; FTM 791-351
Capacity: 2 oil or grease samples
Maximum Temperature: 350°F (177°C)
Temperature Control Stability: ±1°F (± 0.5°C)
Circulation: 1⁄20hp stainless steel impeller
Bath Medium: 5.3 gal (20L) high temperature transfer fluid
Electrical Requirements:
115V 60Hz, Single Phase, 8.6A
220-240V 50/60Hz, Single Phase, 4.5A
Evaporation Loss Test Bath–Constant temperature oil bath mounts two
Evaporation Cells in an upright position at the proper immersion level.
Maintains test temperature within ±1°F (±0.5°C). Microprocessor PID
control provides quick temperature stabilization without overshoot and the bath
is protected by an overtemperature control circuit that interrupts power should
bath temperature exceed a programmed cut-off point. Dual LED displays
provide actual and setpoint temperature values in °C/°F format.
Communications software (RS232, etc.), ramp-to-set and other enhanced
features are available as extra cost options. Contact your Koehler representative
for information. Fully insulated, double-wall construction, with stainless steel
tank and polyurethane-finished steel exterior.
*Also available–special bath to accommodate both ASTM D972 and D942
(Oxidation Stability of Greases on page 152) test methods. Please contact
Koehler for additional information.
Ordering Information
Catalog No.
K29400
K29490
K29500
K29550
Included Accessories
Support Clamps (2)
Thermometer Holder
Dimensions
Evaporation Loss Test Bath, 115V 60Hz
Evaporation Loss Test Bath, 220-240V 50/60Hz
Evaporation Test Cell with Grease Cup
Evaporation Test Cell with Oil Cup
Accessories
33w" x 251⁄2"h (84x65cm)
Maximum width with two evaporation cells inserted
Net Weight: 62 lbs (28.1kg)
250-000-22F
ASTM 22F Thermometer
Range: 204 to 218°F
250-000-22C ASTM 22C Thermometer
Range: 95 to 103°C
250-000-67F ASTM 67F Thermometer
Range: 203 to 311°F
250-000-67C ASTM 67C Thermometer
Range: 95 to 155°C
K29530
Oil Sample Cup with Hood
K29540
Grease Sample Cup with Hood
Shipping Information
Shipping Weight: 90 lbs (40.8kg)
Dimensions: 14.2 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
148
Order Qty
1
2
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 149
Evaporation Loss of Lubricating Greases
Over Wide Temperature Range
Test Method
Similar to the ASTM D972 Evaporation Loss test, extending the temperature
range for evaporation loss testing to 600°F (316°C).
High Temperature Evaporation Loss Tester
• Conforms to ASTM D2595 specifications
• Microprocessor temperature control with digital display
and overtemperature cut-off
• Microprocessor programmable high accuracy temperature control
Performs evaporation loss tests on lubricating greases at temperatures of up
to 600°F (316°C). Maintains sample temperature within ±0.3°F while passing
heated air over the sample surface at a controlled flow rate. Consists of
evaporation cells and aluminum block oven with controls for sample
temperature, air temperature and air flow rate. Evaporation cells include grease
sample cup, head, eduction tube, cover and thermocouple tube. Aluminum
block oven provides efficient response and safe operation at high temperatures.
Microprocessor temperature control has °C/°F switchable digital setpoint and
display. Operator and equipment are protected by an overtemperature control
circuit which automatically interrupts power to the unit when bath temperature
exceeds a programmed cut-off point. Microprocessor PID control provides
quick temperature stabilization without overshoot and the bath is protected
by an overtemperature control circuit that interrupts power should bath
temperature exceed a programmed cut-off point. Dual LED displays provide
actual and setpoint temperature values in °C/°F format. Communications
software (RS232, etc.), ramp-to-set and other enhanced features are available
as extra cost options. Contact your Koehler representative for information.
Separate air preheater controls and flowmeters for each cell permit accurate
control of heated air flow to sample surface. Order accessory Digital
Thermometer (Cat. No. K29310) to monitor exit air temperature and ASTM 3F
or 3C Thermometer for block (sample) temperature. Accessory oil sample cup
(Cat. No. K29530) converts evaporation cell for lubricating oil samples.
Ordering Information
Catalog No.
K29300
High Temperature Evaporation Loss Tester,
220-240V 50/60Hz
Order Qty
1
Accessories
K29320
K29329
250-000-03F
250-000-03C
K29530
K29540
High Precision Digital Thermometer, 115V 60Hz
1
Microprocessor based digital thermocouple
thermometer with ten channel input. Monitors
Type K Thermocouples from evaporation cells
in K29300 Evaporation Loss Tester. Use together
with preheater controls in Model K29300
to maintain air temperature within ±1.1°C (±2°F)
per ASTM specifications
High Precision Digital Thermometer, 220-240V 50/60Hz
ASTM 3F Thermometer
Range: 20 to 760°F
ASTM 3C Thermometer
Range –5 to +400°C
Oil Sample Cup with Hood
Grease Sample Cup with Hood
K29300 High Temperature Evaporation Loss Tester
Specifications
Conforms to the specifications of:
ASTM D2595, D2878*
*with accessory oil sample cup installed
Capacity: 2 samples
Temperature Range: 200 to 600°F (93 to 316°C)
Sample Temperature Control:
Type: microprocessor digital control
Exit Air Temperature Control: Two 0-500W variable control heaters and type K
thermocouples (order K29320/K29329 Digital Thermometer separately)
Air Flow Control: Two externally mounted flowmeters maintaining 2L/min flow
at standard temperature and pressure
Electrical Requirements:
220-240V 50/60Hz, Single Phase, 10.4A
Included Accessories
Evaporation Cell Assemblies with grease sample cups (2)
Type K Thermocouples (2)
Dimensions lxwxh,in.(cm)
25x16x17 (64x41x43)
Net Weight: 175 lbs (79.4kg)
Shipping Information:
Shipping Weight: 224 lbs (101.6kg)
Dimensions: 10.4 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
149
0-148-168_8_LubeGreases_Layout 1 11/1/12 2:09 PM Page 150
Dropping Point of Lubricating Grease
Test Method
Dropping point determinations are used for identification and quality
control purposes, and can be an indication of the highest temperature of
utility for some applications. The sample is heated at a prescribed rate in a
precision machined cup whose sides slope toward an opening at its center.
The temperature at which a liquid drop first falls from the cup is the
dropping point of the sample.
Dropping Point Apparatus
• Conforms to ASTM D566, D4950 and related specifications
Performs dropping point determinations on lubricating greases at
temperatures of up to 550°F (288°C). Consists of dropping point cup, test cell
with accessories and oil bath with stirrer and heater. Test cell is immersed in
a 400mL Borosilicate Glass bath for heating at the prescribed rate. A 750W
variable stepless control heater and 1⁄40hp stirrer permit accurate, uniform
control of bath temperature rate of rise. Heater assembly includes refractory
top plate and reference dial.
Specifications
Conforms to the specifications of:
ASTM D566, D4950; IP 132; ISO 2176; DIN 51801; FTM 791-1421;
NF T 60-102
Maximum Temperature: 550°F (288°C)
Bath Medium: A high temperature heat transfer fluid having a flash point in
excess of 400°C is recommended. Silicone fluid (P/N 355-001-002
— page 8) is suitable.
Electrical Requirements:
115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz. Single Phase, 3.4A
Included Accessories
K19490 Dropping Point Apparatus
Ordering Information
Catalog No.
K19490
K19491
Dropping Point Apparatus,115V 60Hz
Dropping Point Apparatus, 220-240V 50/60Hz
Order Qty
1
Grease Cup, chromium plated brass
Test Tube with indentations
Cork Ring Guide
Thermometer Corks (2)
Thermometer Depth Gauge
Polished Metal Rod
Connecting Hardware
Dimensions lxwxh,in.(cm)
Accessories
250-000-02F
250-000-02C
K194E7
K194E6
K194EA
K19492
K19493
K19499
ASTM 2F Thermometer. Range: 20 to 580°F
ASTM 2C Thermometer. Range: –5 to +300°C
Cup Plug Gauge
Checks conformity of test cup with specifications.
Per Fig. 1, ASTM D566 and Fig. 1-E7, ASTM D2265
Polished Metal Rod
Grease Cup
Test Tube with indentations
Thermometer Cork
Cork Ring Guide
2
1
5x5x31(13x13x78)
Net Weight: 11 lbs (5.0kg)
Shipping Information
Shipping Weight: 16 lbs (7.3kg)
Dimensions: 2.8 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
150
0-148-168_8_LubeGreasesAA2_Layout 1 11/29/12 7:20 PM Page 151
Dropping Point of Lubricating Grease
Over Wide Temperature Range
Test Method
The ASTM D2265 dropping point test permits higher temperatures than the
ASTM D566 method and uses a different heating procedure: the test cell is
inserted in an aluminum block oven maintained at a constant temperature
that is higher than the expected dropping point of the sample. The sample
temperature then rises to the dropping point without operator control.
High Temperature Dropping Point Apparatus
• Conforms to ASTM D2265 and D4950 specifications
• Six-sample testing capability
• Microprocessor programmable high accuracy temperature control
Tests dropping points of lubricating greases at temperatures of up to 400°C
(752°F). Includes thermostatically controlled aluminum block oven and six
complete dropping point assemblies. Six-place oven has large viewing ports
with fluorescent backlighting for excellent visibility. Microprocessor PID
control provides quick temperature stabilization without overshoot and the bath
is protected by an overtemperature control circuit that interrupts power should
block temperature exceed a programmed cut-off point. Dual LED displays
provide actual and setpoint temperature values in °C/°F format.
Communications software (RS232, etc.), ramp-to-set and other enhanced
features are available as extra cost options. Contact your Koehler representative
for information. Microprocessor temperature control with digital readout and
overtemperature safety cut-off maintains block temperature with ±0.5°C
stability. Insulated cabinet has a chemical resistant polyurethane finish.
K19400 High Temperature Dropping Point Apparatus
Ordering Information
Catalog No.
K19400
K19410
High Temperature Dropping
Point Apparatus, 115V 60Hz
High Temperature Dropping
Point Apparatus, 220-240V 50/60Hz
Order Qty
1
Accessories
250-000-03F
250-000-03C
K194E7
K194EA
K194EB
K194EC
K194E1
K194E2
K194E3
K194E4
K194E5
K194E6
ASTM 3F Thermometer
Range: 20 to 760°F
ASTM 3C Thermometer
Range: –5 to +400°C
Cup Plug Gauge
Per Fig. 1, ASTM D566 and
Fig. 1-E-7, ASTM D2265
Grease Cup
Test Tube, 13x100mm
Cup Support
Thermometer Clamp
Upper Bushing
Lower Bushing
Bushing Support Ring
Thermometer Depth Gauge
Polished Metal Rod
7
Specifications
Conforms to the specifications of:
ASTM D2265, ASTM D4950
Maximum Temperature: 400°C (752°F)
Control Stability: ±0.5°C (±1°F)
Electrical Requirements:
115V 60Hz, Single Phase, 6.5A
220-240V 50/60Hz, Single Phase, 3.4A
Included Accessories:
1
Dropping Point Assemblies (6) consisting of: test tube, grease cup,
thermometer clamp, upper and lower bushings and bushing support ring
Thermometer Depth Gauge
Polished Metal Rod
Cup Support
Dimensions lxwxh,in.(cm)
Shipping Information
111⁄2x9x14 (29x23x36)
Net Weight: 241⁄2 lbs (11.1kg)
Shipping Weight: 31 lbs (14.1kg)
Dimensions: 2.6 Cu. ft.
Please inquire about our Automated Dropping Point Test
Equipment by contacting Koehler's Customer Service.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
151
0-148-168_8_LubeGreasesAA2_Layout 1 11/29/12 7:55 PM Page 152
Oxidation Stability of Lubricating Greases
by the Oxygen Bomb Method
K10901 Oxidation Bath with
K11000 Oxidation Bombs
Test Method
The sample is oxidized in a bomb initially charged with oxygen at 110psi
(758kPa) and maintained at elevated temperature for a specified aging
period. The pressure drop inside the bomb is measured by means of a
gauge or transducer.
Oxidation Stability Test Apparatus
• Conforms to ASTM D942 and related specifications
• Four sample testing capability
• Available Oxidata® Pressure Measurement System
Consists of Oxidation Bombs, Sample Dishes, Pressure Measuring and
Recording Equipment and Oxidation Bath.
Oxidation Bomb–Stainless steel bomb consists of body, lid with stem and
needle valve, and dish holder per ASTM specifications. Bomb interior surfaces
and inside of stem have a high polish to facilitate cleaning. Safely withstands
a working pressure of 180psi (1241kPa) at 99°C (210°F). Includes PTFE
gasket seals (3) and cap screws with wrench. PTFE-fluorocarbon seals are
available (see Accessories).
Pressure Measurement and Recording Equipment–Select mechanical
pressure gauges or, for greater convenience and accuracy in test reporting,
the Oxidata® Pressure Management System designed expressly for ASTM
oxidation tests.
Pressure gauge measures pressure inside Oxidation Bomb with accuracy of
better than 0.5psi (3.45kPa) in accordance with ASTM specifications. Range:
0-160psi (0-1100kPa), graduated in 1psi intervals. Cleaned for oxygen service.
Oxidata® Pressure Measurement System–A complete electronic
measurement system based on powerful Oxidata® software for Windows®
and Windows 95® environments. Electronically measures and reports
pressure versus time and accuracy of better than 0.5psi (3.45kPa) in the range
of 0-200psi (0-1378kPa) for four channels in graphical tabular format.
Included RTD attachment permits measurement and reporting of bath
temperature. Includes transducers, data acquisition card, multiplexer,
Oxidata® software, RTD probe assembly and connecting cables and
hardware. Refer to page 115 for complete specifications on Oxidata® software.
Oxidation Bath–Constant temperature oil bath holds bombs at the proper
depth for determining oxidation stability of lubricating greases.
Microprocessor PID control provides quick temperature stabilization without
overshoot and the unit is protected by an overtemperature control circuit
that interrupts power should bath temperature exceed a programmed cut-off
point. Dual LED displays provide actual and setpoint temperature values in
°C/°F format. Communications software (RS232, etc.), ramp-to-set and other
enhanced features are available as extra cost options. Contact your Koehler
representative for information. Heavily insulated welded stainless steel bath
interior has a bomb support rack and overflow standpipe/drain to maintain
proper working depth. Steel exterior has a corrosion-resistant polyurethane
enamel finish.
Also available–Special baths to accommodate two test methods:
• ASTM D942 and D525 (Oxidation Stability of Gasoline–Induction Method
on pages 81-82)
• ASTM D942 and D972 (Evaporation Loss of Lubricating Greases and Oils
on page 149)
• Higher temperature models are available.
Please contact Koehler’s Customer Service for additional information.
152
0-148-168_8_LubeGreasesAA2_Layout 1 11/29/12 7:20 PM Page 153
Oxidation Stability of Lubricating Greases
by the Oxygen Bomb Method
Specifications
Conforms to the specifications of:
ASTM D942; IP 142; DIN 51808; FTM 791-3453
Oxidation Bath:
Capacity: four (4) oxidation bombs
Temperature Range: ambient to 275°F (135°C)
Bath Medium: 12.5 gal (47.3L) white technical oil
Electrical Requirements:
115V 60Hz, Single Phase, 13.0A
220-240V 50/60Hz, Single Phase, 6.8A
Dimensions dia.xh,in.(cm)
Interior: 16x14 (41x36)
Overall: 191⁄2x281⁄2 (50x72)
Shipping Information (with electronic pressure measurement system)
Shipping Weight:
Bath: 75 lbs (34.0kg)
Electronic Pressure Measurement System: 48 lbs (21.8kg)
Dimensions:
Bath: 16.7 Cu. ft.
Electronic Pressure Measurement System: 7.8 Cu. ft.
Oxidata® Pressure Measurement System
Ordering Information
Catalog No.
Order Qty
Oxidation Bomb
K11000
Oxidation Bomb
4
Pressure Measurement and Recording Equipment
Select either Pressure Gauges or Oxidata® Pressure Measurement System*
311-160-003 Pressure Gauge
4
K11005
4-Unit Electronic Pressure Measurement for
Lubricating Grease Oxidation Tests, 115V 60Hz
K11095
4-Unit Electronic Pressure Measurement for
Lubricating Grease Oxidation Tests, 220-240V 50/60Hz
Oxidation Bath
K10901
Oxidation Bath, 115V 60Hz
K10991
Oxidation Bath, 220-240V 50/60Hz
1
Accessories
K11040
250-000-22F
250-000-22C
355-001-001
355-001-003
K10504-0-1
K10551
K10556
K11029
Borosilicate Glass Dish
20
ASTM 22F Thermometer. Range: 204 to 218°F
ASTM 22C Thermometer. Range: 95 to 103°C
1
White Technical Bath Oil, 1 Gallon container
13
White Technical Bath Oil, 5 Gallon container
3
See page 8 for specifications
Transducer Assembly
Pressure Line. For pressurizing Oxidation Bomb.
1
6 ft (1.83m) long, with quick release coupling for
needle valve on bomb and threaded fitting for oxygen tank
Oxygen Manifold Pressure Relief System
Connects to oxygen source to prevent overcharging of
bomb. Equipped with relief valve to vent at 125psi and
300 series stainless steel 150psi burst disk assembly.
Constructed from 300 series stainless steel. Cleaned for
oxygen service.
PTFE-fluorocarbon Gasket
K11000 Oxidation Bomb
*This ordering information is for installation to Koehler grease oxidation test
equipment. For other makes of equipment, a few items of basic hardware may
also be required–please contact your Koehler representative for assistance.
153
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 154
Corrosion Preventive Properties of Lubricating Greases
Corrosion Preventive Properties of
Lubricating Greases
Corrosion Preventive Properties of
Lubricating Greases in Presence of
Dilute Synthetic Sea Water Environments
Test Method
Determines the corrosion preventive properties of greases when distributed
in a tapered roller bearing stored under wet conditions.
Corrosion Preventive Properties Apparatus
• Conforms to ASTM D1743 and D4950 specifications
Distributes a lubricating grease sample in a roller bearing by running the
bearing under light thrust load. Corrosion preventive capability is determined
on a pass/fail basis by the presence of rust spots (1mm or larger) on the
bearing race after a 60 second run-in period followed by prolonged exposure
to water at constant temperature. Consists of variable speed motor, 1750rpm
run-in stand, bearing holder assemblies, spindle/thrust loading device,
mechanical grease packer pliers and test bearings.
Specifications
Conforms to the specifications of: ASTM D1743, D4950, Draft Method, D5969
Drive Motor: 1750rpm
Electrical Requirements:
115V 60Hz, Single Phase, 2.0A
220-240V 50/60Hz. Single Phase, 1.0A
Included Accessories
Bearing Holder Assemblies (3): Consisting of:
1kg weight
upper and lower plastic collars for cone
plastic collar for cup
plastic jar with screw cap
metal screw
Spindle/Thrust Loading Device
Mechanical Grease Packer
Pliers
Test Bearings (3) (cone and roller assemblies)
Dimensions lxwxh,in.(cm)
Shipping Information
10x15x20 (25.4x38.1x50.8)
Net Weight: 27 lbs (12.2kg)
Shipping Weight: 36 lbs (16.3kg)
Dimensions: 5 Cu. ft.
Ordering Information
Catalog No.
K17980
K17989
Corrosion Preventive Properties
Apparatus, 115V 60Hz
Corrosion Preventive Properties
Apparatus, 220-240V 50/60Hz
K17980 Corrosion Preventive
Properties Apparatus
Corrosion Preventive Properties Apparatus
(Alternate Method)
• Conforms to ASTM D1743-73 specifications
Determines corrosion preventive properties of lubricating greases in
accordance with original ASTM D1743-73 specifications, now incorporated
as Appendix #2 in the current ASTM D1743 method. Offers a suitable
alternative to the new method for laboratories needing a quicker screening
test method. Consists of drive motor on base with driving cone hub, thrust
loading device, mechanical grease packer, test bearings (3), bearing supports
(3) and containers with lids (3).
Specifications
Conforms to the specifications of: ASTM D1743-73, FTM 791-4012
Electrical Requirements:
115V 60Hz, Single Phase, 5.2A
220-240V 50/60Hz, Single Phase, 2.6A
Dimensions lxwxh,in.(cm)
Shipping Information
7x12x93⁄4 (18x30x25)
Net Weight: 27 lbs (12.3kg)
Shipping Weight: 36 lbs (16.3kg)
Dimensions: 5 Cu. ft.
Ordering Information
Catalog No.
K17970
Accessories
K17981
K17981-0-2
K17981-0-3
K17982
K17983
K17984
289-004-002
K17979
Bearing Holder Assembly
Upper Flange
Lower Flange
Mechanical Grease Packer
Pliers
Plastic Jar
Test Bearing
Corrosion Preventive Properties Apparatus
(Alternate Method), 115V 60Hz
Corrosion Preventive Properties Apparatus
(Alternate Method), 220-240V 50/60Hz
Accessories (Alternate Method)
K17900
K17910
K17920
K17930
154
Thrust Loading Device and Mechanical Grease Packer
Test Bearing
Bearing Supports
Container with Lid
0-148-168_8_LubeGreasesAA2_Layout 1 11/29/12 7:20 PM Page 155
Copper Corrosion from Lubricating Grease
Test Method
Measures the tendency of lubricating grease to corrode copper under
static conditions. A polished copper strip is immersed in a sample of grease
at elevated temperature for a specified period. The strip is examined for
corrosion and a classification number from 1-4 is assigned based on a
comparison with the ASTM Copper Strip Corrosion Standards.
Copper Strip Tarnish Test Apparatus
• Conforms to ASTM D4048 specifications
Ordering Information
Catalog No.
K25330
Order Qty
Test Tube Bath, 115V 60Hz
1
Constant temperature bath with microprocessor
temperature control. Control features °C/°F switchable
digital setpoint and display and overtemperature cut-off
protection. Temperature range from ambient to 190°C (374°F)
with ±1°C (±2°F) stability. Welded stainless steel inner wall
and powder coated steel outer wall
construction, fully insulated
K25339
Test Tube Bath, 220-240V 50/60Hz
K25308
Test Jar Rack
1
Inserts in K25330/K25339 baths to hold sixteen
332-004-001 Test Jars
332-004-001 Test Jar
16
K25080
Copper Test Strip
16
Conforming to ASTM specifications
380-150-001 Silicone Carbide Paper, 150 grit
1
For polishing of test strips
Pack of 50 sheets
380-240-001 Silicone Carbide Paper 240 Grit
1
For final polishing of test strips
Pack of 50 sheets
380-150-000 Silicone Carbide Grain, 150 Grit
1
For final polishing of test strips. 1 lb package
K25000
Polishing Vise
1
Holds copper strip firmly in place without
marring the edges. Stainless steel,
mounted on a composition base
K25100
ASTM Copper Corrosion Standards
1
Colored reproductions of tarnished strips
encased in plastic
332-004-002 Viewing Test Tube
16
Protects copper strip during inspection or storage
250-000-130F ASTM 130F Thermometer
Range: 20 to 220°F
1
250-000-130C ASTM 130C Thermometer
Range: –7 to +105°C
K460-0-8
Vented Cork
16
K25339 Constant Temperature Bath with 332-004-001 Test Jars
Specifications:
Conforms to the specifications of:
ASTM D4048, FTM 791-5309
Test Tube Bath Capacity: 16 test jars
Maximum Temperature: 190°C (374°F)
Temperature Control Stability: ±1°C (±2°F)
Bath Medium: 5 gal (18.9L) water or high temperature heat transfer fluid
Electrical Requirements:
115V 60Hz, Single Phase, 7.5A
220-240V 50/60Hz, Single Phase, 4A
Dimensions lxwxh,in.(cm)
151⁄2x121⁄2x14 (39x32x36)
Net Weight: 27 lbs (12.2kg)
Shipping Information
Shipping Weight: 40 lbs (18.1kg)
Dimensions: 7.8 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
155
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 156
Roll Stability of Lubricating Grease
Test Method
Provides an indication of shear stability of lubricating greases by
testing the change in worked penetrations after two hours in the roll
stability tester.
Roll Stability Tester
•
•
•
•
K18320 Double-Unit Roll Stability Tester
Specifications
Conforms to the specifications of:
ASTM D1831, MIL-G-10924SA
Maximum Temperature: 200°F (93°C)
Temperature Control Stability: ±2°F (±1°C)
Electrical Requirements (Single and double unit models):
115V 60Hz, Single Phase, 10.5A
220-240V 50Hz, Single Phase, 5.5A
220-240V 60Hz, Single Phase, 5.5A
Conforms to ASTM D1831 and related specifications
Single, double and four-unit models
Microprocessor programmable high accuracy temperature control
High Temperature model
Roll stability apparatus for shear stability tests on lubricating greases.
Rotates steel test cylinders at 10 or 165rpm in a thermostatically
controlled environment at temperatures of up to 200°F (93.3°C). Drive
system is powered by a rugged ratio motor, and interchangeable drive
chain sprockets are easily accessible for converting unit to either
operating speed. Microprocessor PID control provides quick temperature
stabilization without overshoot and is protected by an overtemperature control
circuit that interrupts power should temperature exceed a programmed cut-off
point. Dual LED displays provide actual and setpoint temperature values in
°C/°F format. Communications software (RS232, etc.), ramp-to-set and other
enhanced features are available as extra cost options. Contact your Koehler
representative for information. A balanced cast aluminum fan and 1200W
heater provide efficient, uniform heat distribution. A dial thermometer in
the hinged cover displays chamber temperature. Heaters and drive chain
mechanism are shielded for operator safety. Insulated steel cabinet and
base are finished with a durable polyurethane enamel finish.
High Temperature Model–A high temperature model is also available that
expands the temperature range to 320°F (160°C). Tests can be conducted
using the high temperature model unit for time/temperature specifications
beyond those listed in existing D1831.
Ordering Information
Included Accessories
Catalog No.
Roll Stability Tester
K18300
K18305
K18306
K18320
K18325
K18326
K18340
K18341
Test Cylinders with threaded end caps and O-ring seals
Test Rollers, steel, 5kg
Dimensions lxwxh,in.(cm)
Single-Unit: 161⁄2x183⁄8x15 (42x47x38)
Double-Unit: 161⁄2x183⁄8x15 (42x47x38)
Four-Unit: 25x183⁄8x15 (64x47x38)
Net Weight:
Single-Unit: 98 lbs (44.4kg)
Double-Unit: 116 lbs (52.6kg)
Four-Unit: 187 lbs (84.8kg)
K18345
K18346
K18347
Shipping Information
Shipping Weight:
Single-Unit: 142 lbs (64.4kg)
Double-Unit: 175 lbs (79.4kg)
Four-Unit: 270 lbs (122.5kg)
Dimensions:
Single-Unit: 7.7 Cu. ft.
Double-Unit: 9.8 Cu. ft.
Four-Unit: 16.6 Cu. ft.
K18348
Single-Unit Model, 115V 60Hz
Single-Unit Model, 220-240V 50Hz
Single-Unit Model, 220-240V 60Hz
Double-Unit Model, 115V 60Hz
Double-Unit Model, 220-240V 50Hz
Double-Unit Model, 220-240V 60Hz
Four-Unit Model, 115V 60Hz
High Temperature Four-Unit Model,
115V 60Hz
Four-Unit Model, 220-240V 50Hz
Four-Unit Model, 220-240V 60Hz
High Temperature Four-Unit Model,
220/240V 50Hz
High Temperature Four-Unit Model,
220/240V 60Hz
Accessories
K183-0-1A
K183-0-4
156
Test Cylinder, plated steel
with threaded end caps and O-ring seals
Steel Cylinder Roller
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 157
Apparent Viscosity of Lubricating Greases
Test Method
Ordering Information
Apparent viscosity is used to evaluate pumpability and handling
characteristics of greases and is also suitable for analysis of adhesives,
sealants and other semi-solid products. The sample is forced through
a capillary by means of a gear pump-driven hydraulic system and the
resulting pressure in the system is measured. Apparent viscosity is
then calculated from the flow rate and pressure. Eight different
capillaries and two pump speeds are used to determine the apparent
viscosity at sixteen shear rates.
Catalog No.
Low Temperature Pressure Viscometer
K22690
Low Temperature Pressure Viscometer, 115V 60Hz
K22695
Low Temperature Pressure Viscometer, 220-240V 50Hz
K22696
Low Temperature Pressure Viscometer, 220-240 60Hz
*Please call or write for ordering Information on extended (–100°F)
cooling range.
Pressure Viscometers
Pressure Viscometer
K22600
Pressure Viscometer, 115V 60Hz
K22615
Pressure Viscometer, 220-240V 50Hz
K22610
Pressure Viscometer, 220-240V 60Hz
• Conforming to ASTM D1092 and related specifications
• Mechanically refrigerated low temperature model
Low Temperature Pressure Viscometer–Consists of power, hydraulic and
grease systems with refrigerated test chamber. Hydraulic system includes
constant displacement gear-driven metering pump, hydraulic oil reservoir with
50-mesh screen, stainless steel tubing, high pressure valve and fittings. Drive
motor has interchangeable 40 and 64 tooth gears for two-speed operation.
Four interchangeable gauges of 0-60, 0-100, 0-600 and 0-5000psi ranges
monitor system pressure.
Supplied with three precision machined grease assemblies, each including
piston, caps and thermocouple; set of eight (ASTM Nos. 1-8) stainless steel
capillaries; and wrenches for gauge installation and removal. The
refrigerated test chamber holds three cylinders at a time for sample
preparation. Operating range is from ambient to –65°F (–53.8°C), with
stability of ±0.5°F (±0.3°C). The refrigeration system uses hermetically
sealed, self-lubricating compressors in cascaded configuration to provide
efficient cool-down and trouble-free long term operation.
Floor-mounted cabinet is constructed of polished stainless steel with a
welded reinforced frame.
Pressure Viscometer–Complete apparent viscometer meeting ASTM D1092
specifications. Includes power, hydraulic and grease systems and standard
accessories as supplied with the Low Temperature Pressure Viscometer but
without refrigerated test chamber or stainless steel cabinet. Mounted on a
sturdy base having locating feet for permanent benchtop placement.
Specifications
Conforms to the specifications of:
ASTM D1092
Operating Range: performs apparent viscosity determinations
at sixteen different shear rates
Low Temperature Pressure Viscometer:
Temperature Range: ambient to –65°F (–54°C)
Optional –100°F cooling range available on special order*
Temperature Control Precision: ±0.5°F (±0.3°C) throughout the operating range
Test Chamber Medium: denatured alcohol
Electrical Requirements:
115V 60Hz
220-240V 50Hz
220-240V 60Hz
Accessories
K22690-0-27
K226-0-16
K226-0-22
250-000-74F
250-000-74C
Grease Cylinder Assembly for
Low Temperature Pressure
Viscometer (K22690 Series)
– Includes piston and caps
Grease Cylinder Assembly for Pressure
Viscometer - (K22600 Series)
– Includes piston and caps
Capillary Set. Nos. 1-8
ASTM 74F Thermometer
Range –67.5 to –62.5°F
ASTM 74C Thermometer
Range: –55.4 to –52.6°C
Included Accessories
Stainless Steel Grease Cylinder
Assemblies (3)
Thermocouples (3)
Set of Stainless Steel Capillaries (Nos. 1-8)
Interchangeable Pressure Gauges (4)
Interchangeable Pump Drive Gears, 40 and 64-tooth
Set of Wrenches (3)
Dimensions lxwxh,in.(cm)
Low Temperature Pressure Viscometer: 431⁄4x303⁄4x661⁄4 (110x78x168)
Net Weight: 640 lbs (290.3kg)
Pressure Viscometer: 30x12x36 (76x30x91)
Net Weight: 121 lbs (54.9kg)
Shipping Information
Low Temperature Pressure Viscometer:
Shipping Weight: 900 Ibs (408.2kg)
Dimensions: 89.8 Cu. ft.
Pressure Viscometer:
Shipping Weight: 186 lbs (84.4kg)
Dimensions: 14.8 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
157
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 158
Grease Mobility
Test Method
Determines the resistance of lubricating grease to flow under prescribed
conditions. Mobility is measured in grams per second by pumping the
sample through a standardized SOD pressure viscometer at controlled
temperature and pressure.
Grease Mobility Tester
• U.S. Steel Method; ASTM Draft Method
• Test temperatures as low as –30°F (–34.4°C)
Performs grease mobility tests at low temperatures to predict pumpability
characteristics. Determines the suitability of greases for applications in
centralized or bulk systems where pumps, valves or pipes are used to
distribute or transfer grease. Consists of pressure viscometer, cooling
bath and refrigeration system. The stainless steel pressure viscometer is
fitted with a modified No.1, 40:1 ratio capillary. After the sample is loaded
in the pressure viscometer, the assembly is installed in the cooling bath
and allowed to reach the test temperature. Mechanically refrigerated
cooling bath can attain test temperatures as low as –30°F (–34.4°C) with
stability of ±2°F (±1°C). With the sample at the test temperature, the flow
of grease is started under the selected pressure on a nitrogen tank
regulator. Flow per second is determined by collecting the grease for a
specified period. Includes sample collector turntable.
Ordering Information
Catalog No.
K22680
K22680 Grease Mobility Tester
K22685
Specifications
K22686
Conforms to the specifications of:
U.S. Steel Method; ASTM Draft Method
Minimum Temperature: –30°F (–34.4°C)
Control Stability: ±2°F (±1°C)
Grease Mobility Apparatus,
115V 60Hz
Grease Mobility Apparatus,
220-240V 50Hz
Grease Mobility Apparatus,
220-240V 60Hz
Accessories
Included Accessories
Grease Cylinder (pressure viscometer) with modified No.1, 40:1 capillary
Sample Collector Turntable
Electrical Requirements:
115V 60Hz, Single Phase, 6A
220-240V 50 or 60Hz, Single Phase, 3A
Dimensions lxwxh,in.(cm)
Cooling Chamber: 12x12x30 (30.5x30.5x76)
Refrigeration Unit: 15x12x12 (38x30x30)
Net Weight: 114 lbs (51.7kg)
Shipping Information
Shipping Weight: 188 lbs (85.3kg)
Dimensions: 18.4 Cu. ft.
158
K22680-0-22
K22680-0-16
250-100-001
Grease Cylinder with plunger and fittings
Capillary
Thermometer dial type
Range: –100 to +100°F with 2°F subdivisions
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 159
Low-Temperature Torque of Lubricating Grease
Low-Temperature Torque of Ball Bearing Grease
Low-Temperature Torque of
Grease-Lubricated Wheel Bearings
Test Method
Significant for the design and specification of greases for low
temperature service, the low temperature torque test measures the
extent to which a grease sample retards rotation of a bearing assembly
at the test temperature.
Low Temperature Torque Apparatus
•
•
•
•
•
•
Digital torque indication for two samples
Choice of test rig combinations
Mechanically refrigerated, with standard –65°F (–54°C) operating range
Optional cooling range to –100°F (–73°C)
Conforms to ASTM D1478, D4693 and D4950 specifications
Data acquisition software available
Refrigerated two unit apparatus for ASTM low temperature torque tests on
lubricating greases. Includes an insulated, thermostatically controlled air
chamber with test rigs, drive shafts and externally mounted gear motors.
Rotates drive shafts at 1rpm while electronic load cell-strain gauge indicators
measure the torque required to restrain the test rigs. Digital LED displays
indicate torque for each drive unit and cold chamber temperature. On ASTM
D4693 models, spindle temperature is also indicated for each drive unit.
Includes drive shaft overtorque protection—when drive shaft torque exceeds
a preset value, the drive motors automatically shut down to prevent breakage
of shaft insulators. Standard cooling range of –65°F (–54°C) meets ASTM
requirements for D1478 and D4693 test methods. Optional –100°F (–73°C)
range is available for special testing requirements.
K18860 Low Temperature Torque Apparatus
Ordering Information
Catalog
No.
K18852
K18862
K18853
K18863
K18850
K18860
K18851
K18861
K18854
K18864
K18855
K18865
ASTM D1478 Model for Ball Bearing Greases–Equipped with two test cages
and two 6204 ball bearings per ASTM D1478 specifications.
ASTM D4693 Model for Automotive Wheel Bearing Greases–Equipped with two
spring loaded spindle-bearings-hub assemblies, bearing packer assembly and
bearing installation and removal tools.
Combined ASTM D1478-D4693 Model–Equipped with one test cage and one
6204 ball bearing for ASTM D1478 testing and one spindle-bearings-hub
assembly with bearing packer and tools for ASTM D4693 testing.
Data acquisition software–Data acquisition software facilitates running both
ASTM D1478 and D4693 tests. Graph of torque versus time details starting
torque, running torque and time elapsed. Includes software, data acquisition
board and cable.
ASTM
D1478
Cooling
Range
–65°F(–54°C)
–100°F(–73°C)
–65°F(–54°C)
ASTM
D4693
Combined
ASTM
D1478D4693
–100°F(–73°C)
–65°F(–54°C)
–100°F(–73°C)
Electrical
Requirements
220-240V 50Hz
220-240V 60Hz
220-240V 50Hz
220-240V 60Hz
220-240V 50Hz
220-240V 60Hz
220-240V 50Hz
220-240V 60Hz
220-240V 50Hz
220-240V 60Hz
220-240V 50Hz
220-240V 60Hz
Accessories
K18871
289-001-006
308-230-009
K18860-0-24
Specifications
Conforms to the specifications of:
ASTM D1478, D4693, D4950; FTM 791-334
Cooling Range:
Standard: –65°F (–54°C)
Optional: –100°F (–73°C)
Temperature Uniformity: ±1°F (±0.5°C)
Refrigeration: air cooled mechanical cascade hermetic system
Cabinet: floor-mount, polished stainless steel exterior, rides on swivel casters
Test
Method
K18860-0-16
Data Acquisition Package.
Test Bearing, 6204, for ASTM D1478
Chart Recorder, 115V/230V
Inboard Test Bearing, for ASTM D4693,
LM-67010-LM-67048 tapered roller bearing
Outboard Test Bearing for ASTM D4693,
LM-11910-LM-11949 tapered roller bearing
1
1
1
1
1
Dimensions lxwxh,in.(cm)
Shipping Information
481⁄2x34x451⁄2 (123x86x116)
Net Weight: 600 lbs (272.2kg)
Shipping Weight: 697 lbs (316.1kg)
Dimensions: 6.4 Cu. ft.
159
0-148-168_8_LubeGreases_Layout 1 11/1/12 2:09 PM Page 160
Leakage Tendencies of Automotive Wheel Bearing Greases
Test Method
Evaluates the tendency of automotive wheel bearing grease to separate oil
and/or grease under prescribed laboratory conditions. The test is performed
at elevated temperature in a modified automotive spindle-hub assembly
rotated at 660rpm. Any leakage of oil or grease during the test period is
collected and weighed. See also “ASTM D4290 Accelerated Leakage
Tendencies Method” (Page 161).
Included Accessories
Large (Inner) Bearing (1)
Small (Outer) Bearing (1)
Dimensions lxwxh,in.(cm)
201⁄2x18x15 (52x46x38)
Net Weight: 95 lbs (43.1kg)
Shipping Information
Leakage Tendencies Tester
Shipping Weight: 145 lbs (65.8kg)
Dimensions: 8.3 Cu. ft.
• Conforms to ASTM D1263 and FTM 791-3454 specifications
• Microprocessor programmable high accuracy temperature control
Consists of a modified front wheel hub and spindle assembly with drive
motor and constant temperature air cabinet. Rotates hub at 660rpm while
maintaining spindle temperature at a constant 220°F (104°C) or other
specified temperature. Oil that has separated from the sample grease
during the test period is collected in the hub cap and in a leakage collector
that installs on the spindle. The hub is rotated by a durable 1⁄3hp motor
through a V-belt drive. Microprocessor PID control provides quick
temperature stabilization without overshoot, and the unit is protected by an
overtemperature control circuit that interrupts power should bath temperature
exceed a programmed cut-off point. Dual LED displays provide actual and
setpoint temperature values in °C/°F format. Communications software
(RS232, etc.), ramp-to-set and other enhanced features are available as extra
cost options. Contact your Koehler representative for information. Cabinet is
insulated on all sides and has a hinged cover for easy access to the
hub-spindle assembly. Thermometer ports in the spindle and the cabinet
allow for precise setting and monitoring of test temperature. Housed in a
heavy-gauge steel exterior with polyurethane enamel finish.
High temperature models to 205˚C available. Contact your Koehler
representative for information.
Ordering Information
Catalog No.
Leakage Tendencies Tester
K18700
Leakage Tendencies Tester,
115V 60Hz
K18795
Leakage Tendencies Tester,
220-240V 50Hz
K18790
Leakage Tendencies Tester,
220-240V 60Hz
Accessories
K18723
250-000-07F
250-000-07C
Specifications
Conforms to the specifications of:
ASTM D1263; FTM 791-3454
Maximum Temperature: 250°F (121°C)
Electrical Requirements:
115V 60Hz, Single Phase, 13.0A
220-240V 50Hz, Single Phase, 7A
220-240V 60Hz, Single Phase, 7A
Order Qty
1
289-004-004
289-004-003
Torque Wrench
ASTM 7F Thermometer
Range: 30 to +580°F
ASTM 7C Thermometer
Range: –2 to +300°C
Large (Inner) Bearing
Small (Outer) Bearing
1
2
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
160
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 161
Life Performance and Accelerated Leakage Tendencies
Life Performance of Automotive Wheel Bearing Grease
Leakage Tendencies of Automotive Wheel Bearing
Grease Under Accelerated Conditions
Test Method
Evaluates the high temperature stability of automotive wheel bearing
greases in a modified automotive front wheel hub-spindle-bearings
assembly. The ASTM D3527 Life Performance test employs severe
conditions–25 lbf (111N) thrust load, 1000rpm, 160°C spindle temperature
–to induce grease deterioration and failure. The test continues in a 20/4
hour on/off cycle until grease breakdown causes measured drive motor
torque to increase past an established end point. The number of hours to
failure is the test result. The ASTM D4290 Accelerated Leakage Tendencies
procedure employs similar test conditions for a 20 hour period, after which
leakage of grease and oil is measured and the bearings are washed and
examined for deposits of gum and varnish.
High Temperature Wheel Bearing Grease Tester
• Conforms to ASTM D3527, D4290 and D4950 specifications
• Fully automatic operation
• Digital monitoring of all test functions
Performs life performance and accelerated leakage tendencies tests on
lubricating greases in accordance with ASTM test specifications. Consists of a
modified front wheel hub-spindle-bearings assembly housed in a constant
temperature oven and coupled to a 1⁄4hp variable-speed drive motor. Controls
test functions automatically and provides continuous digital display of motor
torque, rpm, chamber temperature, spindle temperature, time cycle and
elapsed time. Test parameters outside of ASTM specifications can be selected
by the operator for in-house testing. Automatically terminates test and displays
elapsed on-cycle hours when grease deterioration causes drive motor torque
to increase to the calibrated end point. A built-in thirty second time delay
circuit prevents erroneous test terminations due to momentary surges in
motor torque at the beginning of the on-cycle. Insulated constant temperature
oven is equipped with a 1200W heater and balanced 1⁄20 hp circulation fan for
efficient heat distribution. Sliding access doors and a movable platform that
swings the drive motor out of the way provide easy access to the spindle
assembly. Modified steel spindle and hub assembly conforms to all critical
1971 Chevy II dimensions and is fitted with thermocouple, bearing thrust
loading device and anodized aluminum grease collector. All controls and
monitors are housed in a separate cabinet.
Ordering Information
Catalog No.
Wheel Bearing Grease Tester
K18500
High Temperature Wheel Bearing
Grease Tester, 115V 60Hz
K18595
High Temperature Wheel Bearing
Grease Tester, 220-240V 50Hz
K18590
High Temperature Wheel Bearing
Grease Tester, 220-240V 60Hz
Order Qty
1
289-004-002
ASTM 42C Thermometer Range: 95 to 255°C
Inboard Bearing Set
Includes LM67048 Cone and LM67010 Cup
Outboard Bearing Set
Includes LM11949 Cone and LM11910 Cup
Specifications
Conforms to the specifications of:
ASTM D3527, D4290, D4950
Digital controls and displays:
Timer: on/off cycle and real time
Chamber Temperature: °C
Spindle Temperature: °C
Motor rpm: 0-1725rpm
Motor Torque: current draw
Elapsed Time: 9999.9 hr.
Maximum Temperature: 177°C (350°F)
Electrical Requirements:
115V 60Hz, Single Phase, 13A
220-240V 50Hz, Single Phase, 7A
220-240V 60Hz, Single Phase, 7A
Included Accessories
Thermocouples (2)
Thermometer holder
Bearings (1set)
Grease Packer Assembly
Bearing Installation/Removal Tools:
bearing installer, small and large
bearing cup removers, bearing cup installer,
bearing puller and spindle wrenches (pins)
Dimensions lxwxh,in.(cm)
Test Unit: 16x20x153⁄4 (41x51x40)
Control Unit: 16x14x16 (41x36x41)
Net Weight: 145 lbs (65.8kg)
Shipping Information
Shipping Weight: 230 Ibs (104.3kg)
Dimensions: 14.8 Cu. ft.
Accessories
250-000-42C
289-004-001
K18500 High Temperature Wheel Bearing Grease Tester
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
161
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 162
Water Washout Characteristics of Lubricating Greases
Specifications
Test Method
A grease sample is packed in a ball bearing and subjected to a steady
water stream under controlled test conditions. The percentage of
grease washed out in a one hour period is determined by weight.
Water Washout Tester
• Conforms to ASTM D1264, D4950 and related specifications
Rotates a lubricated ASTM ball bearing at 600rpm in a modified
bearing/housing assembly while impinging the bearing with a jet of water
at the specified flow rate and temperature. The tared bearing and bearing
shields are weighed before installation in the bearing housing and again
after testing and drying to determine the amount of sample loss. Consists
of reservoir, bearing housing, circulation system and drive motor.
Reservoir is equipped with cartridge heater, thermoregulator and
thermometer port for accurate temperature control at 100°F and 175°F
(38°C and 79°C) per ASTM specifications. Circulation system includes
constant velocity carbon bearing gear pump, valves and flowmeter
directing a controlled water flow to a capillary (1mm) spray nozzle aimed
at the bearing housing. Rugged 1⁄3hp drive motor rotates test bearing at
600rpm while driving the circulation pump. A two-pulley system permits
independent pump operation to circulate water while heating it to test
temperature. Mounted on a finished steel base with locating feet for
permanent benchtop placement.
Conforms to the specifications of:
ASTM D1264, D4950; IP 215; FTM 791-3252
Drive Motor: 1⁄3hp 1725rpm
Temperature Control: ±1°F (±0.5°C) sensitivity
Electrical Requirements:
115V 60Hz, Single Phase,10.1A
220-240V 50Hz, Single Phase, 5.1A
220-240V 60Hz, Single Phase, 5.1A
Included Accessories
Ball Bearing (2)
Drive Train Guard
Acrylic Reservoir Cover
Outer Bearing Shield
Inner Bearing Shield
Test Bearing
Dimensions lxwxh,in.(cm)
18x12x183⁄4 (46x3Ox48)
Net Weight: 67 lbs (30.4kg)
Shipping Information
Shipping Weight: 102 lbs (46.3kg)
Dimensions: 6.7 Cu. ft.
Ordering Information
Catalog No.
Water Washout Tester
K19200
Water Washout Tester,
115V 60Hz
K19295
Water Washout Tester,
220-240V 50Hz
K19290
Water Washout Tester,
220-240V 60Hz
Order Qty
1
Accessories
289-001-006
K192-1-4
K192-1-6
250-000-15F
250-000-15C
Test Bearing
Outer Bearing Shield
Inner Bearing Shield
ASTM 15F Thermometer
Range: 30 to 180°F
ASTM 15C Thermometer
Range: –2 to +80°C
3
3
3
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
162
0-148-168_8_LubeGreasesAA2_Layout 1 11/29/12 7:20 PM Page 163
Resistance of Lubricating Grease to Water Spray
Test Method
Evaluates the ability of a lubricating grease to adhere to a metal surface
when subjected to a direct water spray under controlled conditions. The
percentage of grease sprayed off a stainless steel test panel after a
specified period is determined by weight.
Water Spray Apparatus
• Conforms to ASTM D4049 specifications
• Improved spray chamber design
Complete Water Spray Apparatus meeting ASTM specifications, including
spray chamber, delivery system and constant temperature reservoir. Sprays
water at the specified rate and temperature on a test panel coated with
sample grease. To test for water spray resistance, fill reservoir with 8L of tap
water and set thermostat at test temperature. Circulate the water through the
system to attain temperature equilibrium and insert the coated test panel in
the spray chamber. Adjust water spray to 40psi (276kPa) and continue for 5
minutes. Water spray system includes 1⁄3hp positive displacement pump;
spray nozzle with snubber fitting: 0-60psi pressure gauge; bypass valve;
shut-off and drain valves; and flexible high pressure water lines. Hinged
acrylic spray chamber cover is recessed into the chamber housing to insure
watertight operation. Two thermometer wells permit separate monitoring of
reservoir and water spray temperatures. Standardized grease application
fixture coats test panel with the required thickness of sample grease. Uses
tap water; does not require water hook-up.
Ordering Information
Catalog No.
Water Spray Apparatus
K18200
Water Spray Apparatus,
115V 60Hz
K18295
Water Spray Apparatus,
220-240V 50Hz
K18290
Water Spray Apparatus,
220-240V 60Hz
Specifications
Order Qty
1
Accessories
250-000-37C
K18210
K18220
ASTM 37C Thermometer
Range: –2 to +52°C
Stainless Steel Test Panel
Grease Application Fixture
K18200 Water Spray Off Tester
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Conforms to the specifications of:
ASTM D4049
Circulation System:
Drive Motor: 1⁄3hp, 1725rpm
Pump: rotary gear positive displacement type
Pressure Gauge: 0-60psi
Temperature Control Stability: ±1°F (±0.5°C)
Electrical Requirements:
115V 60Hz, Single Phase, 13.3A
220-240V 50Hz, Single Phase, 6.8A
220-240V 60Hz, Single Phase, 6.8A
Included Accessories
Stainless Steel Test Panel
Grease Application Fixture
Dimensions lxwxh,in.(cm)
29x18x331⁄2 (74x46x85)
Net Weight: 110 lbs (49.9kg)
Shipping Information
Shipping Weight: 180 lbs (81.6kg)
Dimensions: 14.2 Cu. ft.
163
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 164
Oil Separation From Lubricating Grease
Test Method
Determines the tendency of oil and lubricating grease to separate at
elevated temperature.
Oil Separation Apparatus
• Conforms to ASTM D6184 and FTM 791-321 specifications
Consists of 60 mesh nickel gauze cone with wire handle, tall form 200mL
beaker and cover with hook. Place sample in wire gauze cone and
determine weight loss after heating at test temperature for specified time
period. Withstands test temperatures of up to 900°F (482°C).
Shipping Information
Included Accessories
Net Weight: 1⁄2 lb (0.2kg)
Shipping Weight: 1 lb (0.45kg)
Beaker, 200mL
Cover and Hook Assembly
Cone Assembly
Ordering Information
Catalog No.
K19000
Oil Separation Apparatus
332-002-008
K190-0-1C
K190-0-5
Beaker, 200mL
Cover and Hook Assembly
Cone Assembly
Accessories
K19000 Oil Separation Apparatus
Oil Separation On Storage of Grease
Test Method
Provides a measure of the stability of lubricating grease towards oil
separation during storage.
Oil Separation Apparatus
• Conforms to IP 121 and DIN 51817 specifications
Consists of stainless steel separation cup with cone of 240 mesh woven
wire cloth, 100g metal weight and oil cup. Oil separation is determined by
placing the sample on the wire mesh cone and loading it with the 100g
metal weight. The percentage of sample weight lost is calculated after a
storage period of 42 hours.
Shipping Information
Net Weight: 3⁄4 lb (.34kg)
Shipping Weight: 1 lb (.45kg)
Ordering Information
Catalog No.
K19050
Oil Separation Apparatus
K19050 Oil Separation Apparatus
164
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 165
Oil Separation From Lubricating Grease During Storage
Test Method
Determines the tendency of lubricating grease to separate oil during
storage in a 35 lb pail. The sample is placed on a sieve inside a special
test cell and subjected to 0.25psi (1.72kPa) air pressure at constant
temperature. Any oil that bleeds from the grease during a 24 hour period is
collected in the cell and weighed.
Oil Separation Apparatus
• Conforms to ASTM D1742 and related specifications
• Four sample capability
• Controls temperature and air pressure
Consists of pressure bleeding test cells with air pressure regulation system
and constant temperature air cabinet.
Pressure Bleeding Test Cell–Type A test cell includes cup assembly with funnel
and positioning seat for beaker; cover with air inlet fitting; and 200-mesh stainless
steel sieve strainer with brass support ring. Bayonet type connection and
o-ring seal provide tight closure between cover and base. Cup, funnel and base
are constructed of chrome plated spun copper. Order test beaker separately.
K18910
Constant Temperature
Air Cabinet with K18900 Cell
Constant Temperature Air Cabinet–Provides a constant temperature
environment and regulated air pressure per ASTM specifications. Consists of an
insulated airtight cabinet with pressure system to accommodate four pressure
bleeding test cells. Equipped with electric heater, solid state controller, cooling
coil and circulating fan for efficient temperature control at 77°F (25°C).
Pressure system includes air inlet pressure regulator with gauge, cartesian
manostat, manifold with control valves for four test cells, output gauge,
manostat and gas washing bottle. Built-in pressure relief valve protects against
pressure surge. Cabinet is constructed of double-wall stainless steel with full
insulation. Order thermometer and pressure bleeding test cell separately.
Ordering Information
Catalog No.
K18910
K18919
K18900
Accessories
332-002-009 Test Beaker, 20mL
250-000-57F ASTM 57F Thermometer. Range: –4 to +122°F
250-000-57C ASTM 57C Thermometer. Range: –20 to +50°C
Specifications
Conforms to the specifications of:
ASTM D1742, FTM 791-322
Capacity: four samples
Controller Sensitivity ±1°F (±0.5°C)
Electrical Requirements:
115V 60Hz, Single Phase, 3A
220-240V 50/60Hz, Single Phase, 1.5A
Order Qty
Constant Temperature Air Cabinet,115V 60Hz
1
Constant Temperature Air Cabinet, 220-240V 50/60Hz
Pressure Bleeding Test Cell
4
4
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Dimensions lxwxh,in.(cm)
Interior: 193⁄4x193⁄4x211⁄2 (50x50x55)
Overall: 47*x233⁄4x311⁄4 (119x60x79)
*includes external pressure system components
Net Weight: 121 lbs (54.9kg)
Shipping Information
Shipping Weight: 224 lbs (101.6kg)
Dimensions: 27.8 Cu. ft.
K18900 Pressure Bleeding Test Cell
165
0-148-168_8_LubeGreasesAA2_Layout 1 11/29/12 7:20 PM Page 166
Estimation of Deleterious Particles in Lubricating Grease
Test Method
Detects and estimates deleterious particle contamination in lubricating
greases and other semi-solids and heavy liquids. Grease fillers can be
tested for abrasive contaminants by first mixing them into petrolatum or
grease known to be free of deleterious particles.
Deleterious Particles Determination Apparatus
• Conforms to ASTM D1404 specifications
Complete apparatus per Figure 1 and 2 of ASTM D1404. Rotates plastic plate
30° against stationary plate while applying 200psi pressure. Includes body,
test plate holders, loading screw, calibrated spring with scale for applying test
load and removable cap assembly with milled slot and handle for rotating test
plates. Constructed of stainless steel. Order plastic test plates separately.
Ordering Information
Catalog No.
K19300
K19300 Deleterious Particles Determination Apparatus
Deleterious Particles Determination Apparatus
Order Qty
1
Accessories
K19310
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Plastic Test Plate. For use in Model K19300.
Highly polished. Two (2) required for each test
20
Oil and Grease in Water and Wastewater by Infrared (IR)
Test Method
Specifications
For the determination of oil and grease and nonpolar material in water
and wastewater by an infrared (IR) determination of dimer/trimer of
chlorotrifluoroethylene (S-316) extractable substances from an acidified
sample. Included in this estimation of oil and grease are any other
compounds soluble in the solvent.
Conforms to the specifications of:
ASTM D7066; EPA Methods 413.2 and 418.1
Type: Fixed filter infrared filtometer
Display: 4 digit, 7-segment red LED, 5/8 in. character height
Measurement Range:
For Water: 2 – 1000 ppm (using a 10:1 extraction ratio)
For Soil: 3 – 5000 ppm (using a 1:2 extraction ratio)
Usable Solvents for Extraction Process:
Freon, perchloroethylene, S-316, AK-225 or other infrared transparent solvent
Analysis Time: 10-15 minutes, including extraction process
Operating Temperature Range: 40°F (4°C) to 110°F (45°C)
User Selected Calibration: Zero balance adjustment. Up to 20 point curve
fitting calibration
Repeatability: ± 1ppm
Electrical Requirements:
Voltage – 12VDC, +2% max.
Power – 7.5 watts max., 5 watts typical
Input – Switchcraft 760 plug or equivalent, center positive
Suggested Power Sources:
Wall Supply; AC/DC converter type (supplied as standard
12 volt auto battery adapter connector (optional)
Portable 12 volt battery pack (optional)
Infrared Analyzer
• Analyze produced water on offshore oil rigs
• Monitor effluents from refineries or wastewater treatment and industrial
plants
• Measurement of fats, oil and grease (FOG) discharges
• Determine efficiency of oil/water separation systems
• Conduct soil studies at remediation sites or around underground
storage tanks
• Measurement of residual oil on pre-cleaned metal components
• Determine purity level of reclaimed solvents or virtually any on-site
testing of water and soil requiring measurement of TOG and/or
TPH concentration levels
Recommended for measuring total oil and grease (TOG) and total petroleum
hydrocarbon (TPH) levels in water and soils, as well as fats, oil and grease
(FOG) in water using the traditional EPA methods 413.2 and 418.1 with
Freon-113 or ASTM Method D7066-04 with S-316, also compatible with other
infrared transparent solvents such as hydrocarbon-free spectroscopic grade
perchloroethylene, AK-225 or other infrared transparent solvent as the
extracting solvent. The IR analyzer is ideal for on-site analysis to meet new
European regulations. Since there is no evaporation step in the analysis the
light end volatile components are retained for measurement.
Dimensions wxdxh,in.(cm)
Included Accessories
6.5 x 6.5 x 5 (16.5x16.5x12.7)
Net Weight: 4.5 lb (2.0 kg)
Power Supply
Instruction Manual
166
Ordering Information
Catalog No.
K25552
Infrared Analyzer, 12 VDC
K25551-1
K25551-2
K25551-3
K25501
K25502
K25507
K25509
10mm Quartz Cuvette Cells, Set of 4
Car Adapter Cable
IR Sample Plate, pk 5
External 12V Battery Pack
Carrying Case
Dust Cover
Serial Printer
Accessories
0-148-168_8_LubeGreases_Layout 1 11/1/12 2:09 PM Page 167
Lincoln Ventmeter
Test Method
The K95400 Lincoln Ventmeter evaluates the ventability of grease, which is
useful in determining by consistency what type of greases can be used in a
centralized automatic lubrication system. Furthermore, the size or diameter
of the supply line in an automatic lubrication system can be accurately
determined for a particular type of grease. Pressurizing lubricant grease in
25 feet coil tube to 1800 psi with a grease gun, opening the venting valve
and reading the pressure on the gage after 30 seconds will provide the
supply line size and maximum supply line information for the tested grease
by referring the supplied grease ventmeter reading to supply line reference
charts after measuring of the grease ventablility.
Lincoln Ventmeter
Lincoln Ventmeter, as a simulation device of a centralized lubrication system,
consists of 25 feet coil tube with valve 1 at the pressure gage end and valve 2
at the end where a level grease gun is connected. Build up pressure with the
grease gun attached when valve 1 closed. Open instantly valve 2 when
pressure gage reading stabilizes at 1800 psi. Read the pressure gage after
venting for 30 seconds. Repeat test three times and take an average reading to
determine supply line pipe size and maximum length of supply line.
Test under Different Temperature – The test could be done under any
temperature as application required. The standard test recommend three
temperature: 0°F, 30°F and 75°F. When testing under temperature other than
the ambient, the ventmeter filled with grease should be put in temperature
chamber for at least 4 hours. The same test steps should be used for different
temperature conditions.
K95400 Lincoln Ventmeter
Specifications
Ordering Information
Model:
K95400
Electrical Requirements:
None
Catalog No.
K95400
Lincoln Ventmeter
Dimensions lxwxh
K95400-1
Cleaning Kit
Order Qty
1
Accessories
Overall: 15"x6"x5"
Shipping Information
Shipping Weight: 12 lbs
Dimensions: 16"x10"x6"
167
1
0-148-168_8_LubeGreases_Layout 1 10/24/12 11:35 AM Page 168
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Grease Mobility ......................................................................Page 158
U.S. Steel Method
Nitrogen • Laboratory Balance
Evaporation Loss of Lubricating Greases and Oils .............Page 148
ASTM D972, D2878, IP 183, FTM 791-351
Laboratory Balance • m-Terphenyl • Air Supply
Evaporation Loss of Lubricating Grease
Over Wide Temperature Range.............................................Page 149
ASTM D2595, D2878
Laboratory Balance • m-Terphenyl • Air Supply • Cleaning Solvent
Dropping Point of Lubricating Greases ................................Page 150
Low Temperature Torque of Ball Bearing Greases .............Page 159
ASTM D1478, D4693, D4950, FTM 791-334
Stoddard Solvent • Oven • n-Heptane
Spatula • Desiccant
Low Temperature Torque of Grease-Lubricated
Wheel Bearings ......................................................................Page 159
ASTM D4693, D4950
Laboratory Oven • 1,1,1-Trichloroethane • Mercury
Ethylene Glycol • Ultrasonic Cleaner
ASTM D566, D4950, IP 132, ISO 2176, DIN 51801, FTM 791-1421
Spatula • Mineral Spirits
Leakage Tendencies of Automotive
Wheel Bearing Greases .........................................................Page 160
Dropping Point of Lubricating Grease
Over Wide Temperature Range.............................................Page 151
ASTM D1263, FTM 791-3454
Laboratory Balance • Spatula • n-Heptane
ASTM D2265,D4950
Mineral Spirits
Life Performance and Accelerated Leakage Tendencies Tests
for Automotive Wheel Hearing Greases...............................Page 161
Oxidation Stability of Lubricating Greases by the
Oxygen Bomb Method ...................................................Pages 152-153
ASTM D3527, D4290, D4950
ASTM D942, IP 142, DIN 51808, FTM 791-3453
Laboratory Balance • SAE Low Engine Oil • n-Heptane
Steel Wool • Penetone ECS • Oven • Stoddard Solvent • Isopropanol
Oxygen • Forceps • n-Heptane • Oven • Sulfuric Acid
Distilled Water • Chromic Acid • Soap Powder
Water Washout Characteristics of Lubricating Greases.....Page 162
ASTM D1264, D4950, IP 215, FTM 791-3252
Corrosion Preventive Properties of Lubricating Greases......Page 154
Distilled Water • Stoddard Solvent • n-Heptane
ASTM D1743
Syringe, 100mL • Stoddard Solvent • Laboratory Oven
Isopropanol • Distilled Water • Ammonium Hydroxide
Copper Corrosion From Lubricating Grease by the
Copper Strip Tarnish Test.......................................................Page 155
ASTM D4048, FTM 791-5309
Steel Forceps • Cotton Wool • Oven
Isooctane • Acetone
Resistance of Lubricating Grease to Water Spray ..............Page 163
ASTM D4049
Stoddard Solvent • n-Heptane
Oil Separation From Lubricating Grease .............................Page 164
ASTM D6184; FTM 791-321
Laboratory Oven • Laboratory Balance
Roll Stability of Lubricating Grease .................................... Page 156
Oil Separation On Storage of Grease ...................................Page 164
ASTM D1831, MIL-G-10924SA
IP 121
Spatula
Laboratory Oven • Laboratory Balance
Apparent Viscosity of Lubricating Greases..........................Page 157
Oil Separation From Lubricating Grease During Storage.....Page 165
ASTM D1092
ASTM D1742, FTM 791-322
Hydraulic Oil • Nitrogen • Flexible Tubing • Alcohol
Balance • Kerosene
Air Supply • Mineral Spirits
168
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 169
Bitumens and Waxes
Test Methods
Page
Ductility of Bituminous Materials ASTM D113, P226;
AASHTO T51; ANS A37.11; Federal Specifications SS-R-406C;
USDA Method 51 (BUL 12-16); IP 32; DIN 52013 ..............................170
Automated Softening Point of Bitumen (Ring-and-Ball Apparatus)
ASTM D36, E28; AASHTO T53; IP 58; ISO 4625; DIN 52011;
NF T 66-008; EN 1427, 13179 ..............................................................171
Softening Point of Bitumen (Ring-and-Ball Apparatus)
ASTM D36, D2398, E28; AASHTO T53; IP 58, 198 ............................172
Test Methods
Page
Residue and Oil Distillate in Emulsified Asphalts by Distillation
ASTM D244; AASHTO T59....................................................................176
Blocking and Picking Points of Petroleum Wax
ASTM D1465; TAPPI T652....................................................................177
Melting Point of Petroleum Wax (Cooling Curve)
ASTM D87; IP 55; ISO 3841; DIN 51570; FTM 791-1402 ..................178
Breaking Point of Bitumen, Fraass Method IP 80 ............................172
Oil Content of Petroleum Waxes
ASTM D721; IP 158; ISO 2908; DIN 51571, 51572;
FTM 791-5431 ......................................................................................179
Accelerated Aging of Asphalt Binder by
Pressurized Aging Vessel (PAV) ASTM D6521 ..................................173
Solvent Extractables in Petroleum Waxes
ASTM D3235..........................................................................................179
Effect of Heat and Air on Asphaltic Materials (Thin-Film Oven Test)
ASTM D1754..........................................................................................174
For information on additional testing methods for
bitumens and waxes:
Effect of Heat and Air on a Moving Film of Asphalt
(Rolling Thin Film Oven Test)
ASTM D2872..........................................................................................175
Float Test for Bituminous Materials
ASTM D139; AASHTO T50; ANS A37.2................................................176
–Saybolt Color of Petroleum Waxes–please refer to pages 44, 46-47
–Water in Petroleum Products and Bituminous Materials by Distillation
–please refer to pages 56-57
–Please refer to the Viscosity, Penetration, Flash Point and
General Test Equipment Sections
www.koehlerinstrument.com
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 170
Ductility and Elastic Recovery of Bituminous Materials
Test Method
Determines the ductility of a bituminous material by measuring the
distancein which a sample will elongate before breaking when two ends of
a briquetspecimen of the test material are pulled apart at a specified speed
and temperature. Elastic Recovery is determined by pulling the briquet
specimen to a specified distance at a specified speed and temperature. The
briquet is then cut and the distance in which it takes for the two halves to
reconnect is used to determine the elastic recovery of the test sample.
Semi-Automatic Ductility Testing Machine
•
•
•
•
•
•
•
•
K80060 Constant Temperature Ductility Machine with Circulator
Included Accessories
Standard Model:
Standard Mold (3)
Base Plate
Constant Temperature Model:
Circulation Bath
Remote Temp. Probe, 10 ft. length
Connection Tubing
Standard Mold (3)
Base Plate
Lexan Cover
Dimensions lxwxh,in.(cm)
Standard Model:
861⁄4x19x16 (219.1 x 48.3 x 40.6)
Net Weight: 200 lbs (91.7kg)
Constant Temperature Model:
861⁄4x19x16 (219.1 x 48.3 x 40.6)
Net Weight: 217 lbs (98.5 kg)
Circulation Bath:
153⁄4x81⁄4x221⁄2 (219.1 x 48.3 x 40.6)
Net Weight: 50 lbs (22.7 kg)
Electrical Requirements
Conforms to ASTM D113, D6084 and related specifications
Standard and Constant Temperature Models available
Capable of testing up to 3 samples simultaneously
6” LCD Touch Screen Control Panel
Pre-programmed with Ductility, Recovery, and Custom test methods
Maximum travel length of 150 cm
Variable traction speed from 0.25 to 7.0 cm/min
Constant Temperature model equipped with Lexan Cover for enhanced
temperature stability
Semi-Automatic Ductility Testing Machine designed explicitly for testing
the ductility and elastic recovery of bituminous materials. Features a 6”
LCD touch screen control panel. This integrated touch screen allows the
user to choose between the ductility or recovery test methods. The custom
menu allows for the input of desired speed and time parameters. During
testing, the distance traveled by the specimen is displayed and a simple
touch of the screen can record the distance traveled upon breakage of the
briquet. A motor jogging feature permits locking of the sample carriage
without additional movement after briquet sample is loaded into the
machine.
Specifications
Conforms to the specifications of:
ASTM D113, D5892, D6084, P226; IP 32, 516; DIN 52013, EN 13398; NF T
66-006; AASHTO T 51, T 301; JIS K2207; ANS A37.11; Federal Specification
SS-R-406C; USDA Method 5 (BUL 12-16)
Capacity: 3 molds with samples
Maximum Travel Length: 150 cm
Standard Traction Speed: 5 cm/min
Variable Traction Speed: 0.25 to 7.0 cm/min
Timer: 1-999 min
Ordering Information
115V 60Hz
220-240V 50Hz
220-240V 60Hz
Catalog No.
K80050
Shipping Information
K80060
Standard Model:
Shipping Weight: 350 lbs (159kg)
Dimensions: 923⁄4x 251⁄4x 231⁄4” (235.6 x 64.1 x 59.1cm)
Constant Temperature Model:
Shipping Weight: 368 lbs (167kg)
Dimensions: 923⁄4x 251⁄4x 231⁄4” (235.6 x 64.1 x 59.1cm)
Circulation Bath:
Shipping Weight: 74 lbs (34kg)
Dimensions: 22 x 101⁄2 x 261⁄2” (55.9 x 26.7 x 67.3 cm)
K80068
K80069
Semi-Automatic Standard Ductility Testing Machine,
115V/220-240V 50/60Hz
Semi-Automatic Constant Temperature Ductility
Testing Machine, 115V 60Hz
Semi-Automatic Constant Temperature Ductility
Testing Machine, 220-240V 60Hz
Semi-Automatic Constant Temperature Ductility
Testing Machine, 220-240V 50Hz
Accessories
K80012
K80041
K80013
250-000-63F
250-000-63C
K80050-SFW
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 180 through 187.
170
Standard Mold
Recovery Mold
Base Plate
ASTM 63F Thermometer, Range: 18 to 89°F
ASTM 63C Thermometer, Range: -8 to 32°C
Semi-Automatic Ductility Software
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 171
Automatic Softening Point of Bitumen
(Ring and Ball Apparatus)
Test Method
Determines the Softening Point of Bitumen in the range from 30 to
157°C (86 to 315°F) using the ring and ball apparatus immersed in
distilled water (30 to 80°C), USP glycerine (above 80 to 157°C), or
ethylene glycol (30 to 110°C).
Automatic Softening Point Apparatus
•
•
•
•
•
•
•
•
•
•
Conforms to ASTM D36 and related test specifications
Optical detectors for automatic measurement of softening point
Data Storage: 200 Results
Quick access to calibration parameters
Auto diagnostic
Four programmable preset test methods available
Controllable heating rate and stirring speeds
Preheating cycle
Cooling by fan at the end of the test
Waterproof heating element
K87800 Auto Softening Point Apparatus
Dimensions wxdxh,in.(cm)
Adapter: 101⁄4 x21x20 (26x53.5x50)
Specifications
Shipping Information
Conforms to the specifications of:
ASTM D36; AFNOR T66-008; EN 1427; ISO 4625; NF EN 1427; IP 58;
DIN 52011
Shipping Weight: 44 lbs (20 kg)
Ordering Information
Included Accessories
Printer
Glass Beaker (2)
Shouldered Rings (10)
Load Balls (10)
Craddle
Pt 100 Probe
Detection Cable
Stirrer
RS232C Output
Catalog No.
K87800
K87890
Automatic Softening Point Apparatus, 115V 60Hz
Automatic Softening Point Apparatus, 230V 50Hz
K87800-1
K87800-2
K87800-3
K87800-4
K87800-5
K87800-6
K87800-7
K87800-8
K87800-9
K87800-10
Glass Beaker
Straight Rings, Pack of 10
Shouldered Rings, Pack of 10
Conical Rings, Pack of 10
Detection Lamp
Ring & Ball Cradle
PT 100 Probe
Heating Element, 1000W
Roll of Printer Paper
Load Ball, Pack of 10
Accessories
Electrical Requirements
115V 60Hz
230V 50Hz
171
0-169-180_9_BitWaxAA2_Layout 1 11/29/12 7:23 PM Page 172
Softening Point of Bitumen (Ring-and-Ball Apparatus)
Test Method
Ordering Information
The sample is cast in shouldered rings and heated at a controlled rate under
the weight of a steel ball. The softening point is the temperature at which
the bitumen disks soften and sag downward a specified distance.
Catalog No.
K80000
Softening Point Apparatus
K42000
Order Qty
1
Accessories
• Conforms to ASTM D36 and related specifications
Consists of 800mL beaker, 2 standard balls, shouldered rings, ball centering
guides, ring holder, bottom plate and beaker cover with support rods. Order
thermometer and heater separately.
K42090
250-000-15F
250-000-15C
250-000-16F
250-000-16C
K80001
K80002
K80003
K80000 Ring-and-Ball Apparatus
Softening Point Apparatus
Powertrol Heater
1000W heater with variable stepless control and porcelain
refractory top plate with positioning well for beaker.
Enclosed in a stainless steel housing with cooling vents,
Shipping Weight: 8 lbs, 14 oz (3.6kg). 115V 60Hz
Powertrol Heater, 220-240V 50/60Hz
1
ASTM 15F Thermometer
Range: 30 to 180°F
1
ASTM 15C Thermometer
Range: –2 to +80°C
1
ASTM 16F Thermometer
Range: 85 to 392°F
ASTM 16C Thermometer
Range: 30 to 200°C
Ring. Brass, shouldered ring conforming to
ASTM specifications. Pack of 10
Ball. Hardened steel, conforming to
ASTM specifications. Pack of 10
Ball-Centering Guide
Specifications
Shipping Information
Conforms to the specifications of:
ASTM D36, E28; AASHTO T53;
IP 58, 198; NF T 66-008
Shipping Weight: 4 lbs (1.8kg)
Breaking Point of Bitumen, Fraass Method
Test Method
Ordering Information
Determines the breaking point of solid and semi-solid bitumens. A thin
steel plaque is coated with the sample and flexed in a bending apparatus
at descending temperatures until cracks appear in the sample coating.
Catalog No.
K28300
K28310
Breaking Point Apparatus
K28320
K28321
250-000-33C
• Conforms to IP 80 specifications
Consists of two concentric borosilicate glass tubes with movable steel
plate holders. A cone-and-peg mechanism moves the inner tube up and
down relative to the outer tube, which varies the distance between the
plate holders, causing the stainless steel test plate to be flexed. The inner
tube accommodates a test thermometer. Supplied with 12 spring stainless
steel plaques.
Order Qty
Bending Apparatus
1
Cooling Apparatus
1
Consists of test tubes, cylinder, bungs and thistle tunnel
Electric Hotplate, 115V 50/60Hz
1
Electric Hotplate, 220-240V 50/60Hz
ASTM 33C Thermometer. Range: –38 to + 42°C
1
Shipping Information
Shipping Weight: 20 lbs (9.1kg)
Dimensions: 2.5 Cu. ft.
172
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 173
Accelerated Aging of Asphalt Binder Using a
Pressurized Aging Vessel (PAV)
Test Method
Specifications
For accelerated aging (oxidation) of asphalt binders by means of
pressurized air and elevated temperature. This is intended to simulate the
type of changes which occur in asphalt binders during in-service oxidative
aging but may not accurately simulate the relative rates of aging. It is
intended for use with residue from Test Method D2872 (RTFOT) which is
designed to simulate plant aging.
Conforms to the specifications of:
ASTM D6521; AASHTO R28
Operating Pressure: 2.10 ± 0.05 MPa (304 psi)
Temperature Range: 90°C to 110°C (194°F to 230°F)
Temperature Control Resolution: ± 0.1°C
Test Temperature Uniformity: ± 0.5°C
Time to Set point: 3 hours from ambient
Return to Set point: 120 min. after preheating and lading of specimens
Pressure Vessel: ASME code section VIII, division 1; 1992 A 93
Maximum Pressure: 325 psi (2.24 MPa) at 120°C (250°F)
Pressure Safety Release: 325 psi (2.24 MPa)
Pressure Aging Vessel (PAV)
The Pressure Aging Vessel (PAV) is used to simulate in service oxidative
aging of asphalt binder according to procedures developed by the
Strategic Highway Research Program (SHRP). The K88100 is fully
compliant with the most recent ASTM and AASHTO standards for these
tests. The complete PAV system consists of an ASME-code stainless steel
pressure vessel in a stainless steel cabinet with encased band heaters, a
precision sample holder for simultaneous testing of ten specimens, a set
of ten TFOT specimen trays, a pressure controller, temperature controller,
pressure and temperature measurement devices, temperature recorder,
and a specimen loading and unloading tool.
The K88100 PAV takes the hassle out of running and documenting asphalt
binder aging operations. Three easy, non-complicated steps produce
accurate and reliable results. Just press the "heat" button, inset specimens
when prompted and press the "Age" button and let the PAV do the rest.
Custom status screens guide the user step-by-step through the entire
process. Each display screen (preheat start-up, preheat ready, aging heat
up, aging pressurized, and aging complete) is simple and direct, with
detailed process and status information. The final output screen, when the
test is complete, shows the current vessel pressure, as well as minimum
and maximum temperatures achieved during the test procedure. Process
data (temperature and pressure) is continually stored at regular intervals
in the programmable logic controller (PLC) that controls and monitors the
process.
The K88100 features a compact, bench top design with integral pressure
vessel. Its rotating vessel lid with rounded support block provides easy
opening and closing. A built-in timer accumulates and records out-ofrange time (out of range time for the PAV is typically less than 10 minutes
during a 20-hour test). Minimum and maximum temperature data is
recorded and is displayed at the end of each test.
173
Ordering Information
Catalog No.
K88100
Pressure Aging Vessel, 230V 50/60Hz
K88100-1
K88100-2
K88100-3
K88100-4
K88100-5
K88100-6
UPS Battery Backup System
PAV Verification Kit
PAV O-Ring
CGA Adapter
High Pressure Hose
Specimen Pans Set (Pk / 10)
Accessories
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 174
Loss on Heating of Oil and Asphaltic Compounds
Effect of Heat and Air on Asphaltic Materials
(Thin Film Oven Test)
Test Method
Determines the effect on asphaltic materials of heating in an oven under
prescribed conditions. The results are reported in terms of change in
sample mass and/or changes in selected properties such as viscosity,
penetration and ductility as evidenced by test data taken before and after
the oven cycle.
Asphalt Oven
Dual purpose oven for loss of heat test and thin film test for bitumen and
asphaltic materials. Interior chamber of stainless steel and stored powder
painter steel exterior. Double glazed window in door for viewing test chamber.
Side mounted controls comprise microprocessor digital control, independent
overheat thermostat, main switch and indicator lamps. Two rotating platforms
supplied to perform both the tests.
K45850 Loss on Heat / Thin Film Oven
Specifications
Conforms to the specifications of:
ASTM D6, D1754; Specification E145, Type 1B; AASHTO T47,
T179, BS2000
Temperature Range: to 356˚F (180˚C)
Pre-set at 163˚C ± 1˚C
Electrical Requirements:
110V 60Hz
220V 50Hz
Ordering Information
Catalog No.
K45850
Order Qty
Loss on Heat/Thin Film Oven for D6, D1754
110V, 60Hz
1
K45859
Loss on Heat/Thin Film Oven for D6, D1754
220V, 50Hz
388-001-003
K17000
K17090
Sample Container for ASTM D6
Thin Film Oven Pan, aluminum for D1754
Thin Film Oven Pan, stainless steel for D1754
Dimensions
Accessories
Internal Chamber Dimension 38cm(H) x 52cm(W) x 46cm(D)
External Dimension 57cm(H) x 87cm(W) x 63cm(D)
(External Dimension does not include motor or handle)
Net Weight: 44kg
174
9
4
4
0-169-180_9_BitWaxAA_Layout 1 11/5/12 11:45 AM Page 175
Effect of Heat and Air on a Moving Film of Asphalt
Effect of Heat and Air on a Moving Film of Asphalt
(Rolling Thin Film Oven Test)
Test Method
Determines the effect of heat and air on a moving film of asphalt to serve
as an indicator of approximate change in properties during conventional
hot-mixing. The results are reported in terms of the changes in selected
properties such as viscosity, penetration and ductility brought about by the
RTFO test, as evidenced by test data taken before and after the 75 minute
oven cycle.
Rolling Thin Film Oven
• Conforms to the specifications of ASTM D2872
Double-walled electrically heated convection oven for rolling thin film oven
tests on asphalts. Incorporates all required features per ASTM specifications,
including: door with double-pane viewing window; symmetrical top and
bottom vents; air plenum; squirrel cage-type 1725rpm fan; digital indicating
thermostat to control oven temperature at 163°C ±0.5°C; vertical circular
carriage to mechanically rotate the samples at 15 ±0.2rpm; air jets to blow
heated air into each sample bottle at its lowest point of travel; and a calibrated
flowmeter to control air flow at 4000mL/min. An overtemperature cut-off
circuit disconnects power to the unit in the event of control failure.
K88000 Rolling Thin Film Oven
Ordering Information
Specifications
Catalog No.
K88000
K88001
Conforms to the specifications of: ASTM D2872; AASHTO T240
Included Accessories
Glass Sample Container (8)
ASTM 13C Thermometer
Rolling Thin Film Oven, 220-240V 60Hz
Rolling Thin Film Oven, 220-240V 50Hz
Order Qty
1
Accessories
K88000-1
K88000-2
250-000-13C
Dimensions lxwxh,in.(cm)
40x36x26 (101.6x91.44x66.04)
Net Weight: 310 lbs (141kg)
Glass Sample Container
Cooling Rack
ASTM 13C Thermometer
Range: 155 to 170°C
8
1
Shipping Information
Shipping Weight: 380 lbs (173kg)
Dimensions: 7.96 Cu. ft.
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
Electrical Requirements
220-240V 60Hz
220-240V 50Hz
175
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 176
Float Test for Bituminous Materials
Test Method
Provides a measure of the consistency of bituminous materials,
including asphalts and tar products.
Float Test Apparatus
• Conforms to ASTM D139, AASHTO T50 and ANS A37.2 specifications
Consists of aluminum float and three brass collars for determining the
consistency of bituminous materials and tar products.
Shipping Information
Shipping Weight: 3 lbs (1.4kg)
Ordering Information
Catalog No.
K30500
Float Test Apparatus
Order Qty
1
K30500 Float Test Apparatus
Accessories
K30510
K30520
250-000-15F
250-000-15C
Float, only
Collar, only
ASTM 15F Thermometer
Range: 30 to 180°F
ASTM 15C Thermometer
Range: –2 to +80°C
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
1
Residue & Oil Distillate in Emulsified Asphalts by Distillation
Test Method
Determines residue and oil distillate in emulsified asphalt for research,
quality control and specification acceptance purposes.
Residue and Oil Distillate Determination Apparatus
• Conforms to ASTM D244 and AASHT0 T59 specifications
Consists of an aluminum alloy still with lid and clamp assembly, ring
burner, connection apparatus, graduate cylinder and thermometers.
Shipping Information
K31900: Shipping Weight: 7 lbs (3.2kg)
Dimensions: 1.3 Cu. ft.
K31956: Shipping Weight: 18 lbs (8.2kg)
Dimensions: 2.8 Cu. ft.
Ordering Information
Catalog No.
K31900
Aluminum Alloy Still
Order Qty
1
Accessories
K31910
K31956
332-002-003
250-000-07F
250-000-07C
Ring Burner, 5" (12.7cm) dia
Connection Apparatus
Includes Borosilicate Glass condenser with
metal jacket, tin shield, clamps and stand
Graduated Cylinder, 100mL
ASTM 7F Thermometer
Range: 30 to 580°F
ASTM 7C Thermometer
Range: –2 to +300°C
1
1
1
K31900 Metal Still
2
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
176
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 177
Blocking and Picking Points of Petroleum Wax
Specifications
Test Method
Blocking point and picking point are indicators of the temperature above
which surface film injury will occur when waxed surfaces come in contact
with one another as on a roll of wax paper. Paper test specimens are
coated with the wax sample, folded with the waxed surfaces together, and
heated on a metal blocking plate having a measured temperature gradient.
After a specified period, the specimens are removed and unfolded, and
the points at which film disruption occurred are noted together with their
corresponding temperatures.
Conforms to the specifications of: ASTM D1465; TAPPI T652
Electrical Requirements:
Wax Coating Device: 115V 60Hz, Single Phase, 1.7A
220-240V 5060Hz, Single Phase, .9A
Type A Blocking Plate: 115V 60Hz, Single Phase, 2.1A
220-240V 50/60Hz, Single Phase, 1.1A or
Type B Blocking Plate: 115V 60Hz, Single Phase, 3.4A
220-240V 50/60Hz, Single Phase, 1.8A
Included Accessories
Blocking and Picking Points Apparatus
• Conforms to ASTM D1465 and TAPPI T652 specifications
• Choice of Type A or Type B Blocking Plates
Applies wax samples to paper test specimens and creates a temperature
gradient for determining blocking point and picking point temperatures.
Wax Coating Device–Coats paper with wax samples per ASTM
specifications. Consists of an insulated electrically heated hot wax bath
and a cooling water bath with doctor rods and paper roller. Variable auto
transformer and 200W heater situated underneath the hot wax bath heat
sample to a temperature above the melting point. Doctor rods connect to
an external hot water supply to maintain proper temperature. Cooling bath
has water inlet/outlet fittings, and each bath has a built-in paper guide.
Blocking Plates–Choice of Type A or Type B plates per ASTM specifications.
Type A Aluminum Blocking Plate uses a strip heater and cooling coil on
opposite ends of the block to create a temperature gradient. Six
thermocouples along the length of the block input to accessory Digital
Thermometer. Accommodates eight rows of paper test specimens.
Type B Aluminum Blocking Plate uses two thermostatically controlled baths
to establish a temperature gradient, with the ends of the plate extending into
the baths. Cold bath has a cooling coil and 100W immersion heater; hot bath
has a 300W immersion heater. Thermoregulators and motor stirrers provide
uniform temperature control in each bath. Ten thermocouples along the
length of the block input to accessory Digital Thermometer. Accommodates
six rows of test specimens.
Type A Blocking Plate:
Steel weights, 1x1x30"(8)
Sponge rubber pads (8)
IC thermocouples (6) or
Type B Blocking Plate:
Steel weights, 1x1x6" (24)
Sponge rubber pads (8)
IC thermocouples (10)
Dimensions lxwxh,in.(cm)
Wax Coating Device: 19x8x12 (48x20x30)
Type A Blocking Plate: 38x12x2 (97x30x5)
Type B Blocking Plate: 19x8x12 (48x20x30)
Shipping Information
Shipping Weight:
Wax Coating Device: 44 lbs (20kg)
Type A Blocking Plate: 164 lbs (74.4kg)
Type B Blocking Plate: 183 lbs (83.0kg)
Dimensions:
Wax Coating Device: 5.3 Cu. ft.
Type A Blocking Plate: 4.1 Cu. ft.
Type B Blocking Plate: 12.3 Cu. ft.
Digital Thermometer–Ten-channel microprocessor based digital
thermocouple thermometer with large LED display. Ten-position front panel
rotary selector switch. Mounted in a heavy duty bench case.
177
Ordering Information
Catalog No.
Order Qty
Wax Coating Device
1
K17100
Wax Coating Device, 115V 60Hz
K17190
Wax Coating Device, 220-240V 50/60Hz
Blocking Plates
1
K17200
Type A Blocking Plate, 115V 60Hz
K17290
Type A Blocking Plate, 220-240V 50/60Hz
K17300
Type B Blocking Plate.
115V 60Hz
K17390
Type B Blocking Plate.
220-240V 50/60Hz
Digital Thermometer
1
K29310
Digital Thermometer, 115V 60Hz
K29319
Digital Thermometer, 220-240V 50/60Hz
K17110
Test Paper, Cereal glassine, 30 lb basic weight.
1
31⁄2" (8.9cm) wide x 6" (15.25cm) dia. roll
on a 3" (7.6cm) dia. core.
Thermometers
2
Use with Type B Blocking Plate only.
250-000-09F ASTM 9F Thermometer
Range: 20 to 230°F
250-000-09C ASTM 9C Thermometer
Range: –5 to +110°C
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 178
Melting Point of Petroleum Wax (Cooling Curve)
Test Method
Periodic temperature measurements are taken of a sample of molten
wax as it is cooled in an air bath. When the wax solidifies, a plateau
in the cooling curve occurs, indicating the melting point (cooling
curve) of the sample.
Wax Melting Point Apparatus
• Conforms to ASTM D87 and related specifications
Cools molten wax samples in accordance with ASTM and related
specifications. Consists of nickel-plated air and water bath assembly with
removable cover. Supports test tube in a vertical position in the air bath.
Specifications
Conforms to the specifications of:
ASTM D87; IP 55; ISO 3841; DIN 51570; FTM 791-1402; NF T 60-114
Included Accessories
Test Tube, Thermometer Holders (2)
Dimensions dia.xh,in.(cm) 51⁄2x7 (14x18)
Net Weight 4 lbs (1.8kg)
Shipping Information
Shipping Weight: 6 lbs (2.7kg)
Dimensions: 0.7 Cu. ft.
K17500 Wax Melting Point Apparatus
Ordering Information
Catalog No.
K17500
Wax Melting Point Apparatus
Order Qty
1
Accessories
250-000-14F ASTM 14F Thermometer Range: 100 to 180°F
250-000-14C ASTM 14C Thermometer Range: 38 to 82°C
K175-0-8
Test Tube, 25x100mm
2
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
178
0-169-180_9_BitWaxAA3_Layout 1 11/30/12 12:03 PM Page 179
Oil Content and Solvent Extractables in Petroleum Waxes
Oil Content of Petroleum Waxes
Solvent Extractables in Petroleum Waxes
Specifications
Test Method
Oil content or solvent extractables in wax can affect key properties such
as strength, hardness, melting point, etc. The sample is dissolved in
methyl-ethyl ketone or a 50-50 mixture of methyl-ethyl ketone and
toluene, cooled to precipitate the wax, and filtered. The oil content or
solvent extractables content of the filtrate is then determined by
evaporating the solvent and weighing the residue.
Oil-Solvent Extractables Content Apparatus
Conforms to the specifications of:
ASTM D721, D3235; IP 158; ISO 2908;
DIN 51571, 51572; FTM 791-5431
Electrical Requirements:
115V 60Hz, Single Phase, 0.8A
220-240V 50/60Hz, Single Phase, 0.4A
Included Accessories
Weighing Bottles, 15mL (4)
Filter Stick Assembly (K17630)
Air Pressure Regulator (K17640)
Dimensions lxwxh,in.(cm)
• Conforms to ASTM D721, D3235 and related specifications
Determines oil content or solvent extractables content in petroleum waxes in
accordance with ASTM specifications. Includes Filter Stick Assembly; Cooling
Bath; Air Pressure Regulator; and Evaporation Cabinet.
Filter Stick and Assembly–Filters petroleum wax samples per ASTM
specifications. Consists of 10mm diameter sintered glass filter stick with air
pressure inlet tube and delivery nozzle, and a 25x170mm test tube. Inserts in
Cooling Bath.
Cooling Bath: 8x6x9 (20x15x23)
Evaporation Cabinet: 9x5x16 (23x13x41)
Net Weight:
Cooling Bath: 6 lbs (2.7kg)
Evaporation Cabinet: 7 Ibs (3.2kg)
Shipping Information
Shipping Weight: 24 lbs (10.9kg)
Dimensions: 5 Cu. ft.
Cooling Bath–Accommodates three (3) 25x170mm test tubes for cooling
samples and filter stick assemblies. Insulated stainless steel tank with
finished steel exterior. Removable composition top plate has thermometer
port, filling port and three 25.4mm (1") test tube ports. Fill tank with
suitable cooling mixture.
Air Pressure Regulator–Controls air flow to the filter stick assembly at the
required rate. Mercury bubbler-type, with 250mL glass cylinder, T-tube and
rubber stopper.
Evaporation Cabinet–Thermostatically heated cabinet evaporates solvent
from filtrate per specifications. Accommodates four weighing bottles. Delivers
air stream vertically downward into bottles through glass jets. Manifold
assembly is adjustable for positioning of jets at the correct height above the
sample surface. Controls temperature at 35 ±1°C (95 ±2°F). Finished steel
cabinet with composition front plate and hinged glass door.
Ordering Information
Catalog No.
K17600
K17690
Order Qty
Oil-Solvent Extractables Content Apparatus,
1
115V 60Hz
Oil-Solvent Extractables Content Apparatus,
220-240V 50/60Hz
Accessories
K17605
K17695
332-004-009
250-000-71F
Mechanically Refrigerated Cooling Bath,
115V 60Hz, Ambient to -35°C
Mechanically Refrigerated Cooling Bath,
220-240V 50/60Hz, Ambient to -35°C
Test Tube, 25x170mm
ASTM 71 F Thermometer
Range: –35 to +70°F
4
1
For NIST traceable certified thermometers, please refer to the ASTM Thermometer section on
pages 184 through 191.
179
0-169-180_9_BitWax_Layout 1 10/24/12 11:37 AM Page 180
Additional Accessories
Additional equipment, materials and/or reagents are required to perform some
of the test procedures in the preceding pages. Please refer to the applicable
test method for further information, or contact Koehler for assistance.
Residue and Oil Distillate in
Emulsified Asphalts by Distillation ........................................Page 176
Ductility of Bituminous Materials ..........................................Page 170
No. 50 300 µm Sieve
No. 20 850 µm Sieve
Condenser
Xylol
ASTM D113, D-4; AASHTO T51; ANS A37.11; Federal Specification
SS-R-406C; USDA Method 51 (BUL 12-16); IP 32; DIN 52013
Glycerin
No. 50 300 µm Sieve
150mL Beaker, Griffin Low-form
Carbon Disulfide
Celite Analytical Filter Aid (CAFA)
Evaporating Dish
Analytical Balance
Suction Pump
Filtering Crucible, Porcelain
Dextrin, Talc or Kaolin
Spatula
30mL Beaker, Griffin Low-form
Drying Oven
Watch Glasses
Desiccator
Filtering Flask, with Crucible Adapter
Bunsen Burner or Muffle Furnace
Softening Point of Bitumen
(Ring-and-Ball Apparatus) ...............................................Page 171-172
ASTM D36, E28; AASHTO T53; IP 58, IP 198
Distilled Water
Ethylene Glycol
Silicone Oil or Grease
Dextrin or Talc
Spatula
Breaking Point of Bitumen......................................................Page 173
IP 80
Acetone
Solid Carbon Dioxide
Effect of Heat and Air on Asphaltic Materials.......................Page 174
ASTM D1754
ASTM D244 and AASHTO T59
Blocking and Picking Points of Petroleum Wax ...................Page 177
ASTM D1465; TAPPI T652
Trimming Board
Analytical Balance
Paper Cereal Glassine
Melting Point of Petroleum Wax (Cooling Curve) ................Page 178
ASTM D87; TAPPI T630M-61; IP 55; ISO 3841; DIN 51570; FTM 791-1402
Heating Device
Oil Content of Petroleum Waxes
Solvent Extractables in Petroleum Waxes ............................Page 179
ASTM D721, D3235; TAPPI T636; IP 158; ISO 2908,
DIN 51571, 51572; FTM 791-5431
Dropper Pipet, 15mL
Transfer Pipet, 15mL
Analytical Balance
Wire Stirrer
Methyl Ethyl Ketone
Toluene
Anhydrous Calcium Sulfate
Air Supply
Drying Oven
Kerosene
Cotton
Laboratory Oven with Rotating Shelf
Analytical Balance
Float Test for Bituminous Materials.......................................Page 176
ASTM D139; AASHTO T50 and ANS A37.2
Spatula
180
0-181-182_10_Standards_Layout 1 10/24/12 11:38 AM Page 181
Certified Petroleum Standards
Test Methods
Page
Certified Petroleum Standards Listing................................................182
Koehler offers laboratory reference standards for our full line of
testing equipment. Each test standard comes with original certification
listing the ASTM test method, the name and ISO status of each testing
laboratory, and the average test result and standard deviation. Please
inquire with Koehler’s Customer Service Department about further
information as well as ordering these reference standards for your
testing needs.
www.koehlerinstrument.com
0-181-182_10_Standards_Layout 1 10/24/12 11:39 AM Page 182
Certified Petroleum Reference Standards
Certified Petroleum Reference Standards
x
•
Complete certification is provided with each standard. Refer to the list below
for the reference standard that you require or contact us to discuss your needs
for a special standard. Detailed datasheets and quotations for standards listed
below or for specially prepared standards are readily available from Koehler
by contacting our Customer Service Department. We will respond to you
promptly upon receiving your request.
Manufactured and certified for ASTM and related test procedures
NIST traceable standards developed utilizing ASTM Round Robin trials
Custom standards available
•
•
Koehler offers an extensive range of certified petroleum reference materials
meeting the analytical requirements for ASTM, ISO, EPA, and related test
methods, and are traceable to National Institute of Standards and Technology.
Certified Standards for Petroleum Test Methods
Certified Standards for Petroleum Test Methods (cont’d)
---D56
D86
D92
D93
D97
D323
D445
D611
D613
D1015
D1319
D1744
D2162
D2386
D2500
D2699
D2700
D2789
D2887
D3230
D3231
D3237
D3242
D3340
D3524
D3605
D3606
D3610
D3710
D3798
D3831
D4052
D4053
D4059
D4110
D4291
D4327
D4377
D4420
D4628
D4629
D4815
D4927
D4928
D4929
D4951
D4953
D5056
D5059
D5134
D5184
D5186
D5188
D5191
D5307
D5441
D5442
D5443
D5480
D5482
D5501
D5580
D5599
D5600
D5622
D5623
D5708
D5762
D5769
D5771
D5772
D5773
D5863
D5901
D5949
D5950
D5972
D5985
D5986
D6160
D6258
D6277
D6293
D6296
D6304
D6352
D6371
D6378
D6379
D6417
D6443
D6481
D6550
IP170
PIANO, PONA, PNA by GC
O-PONA Method by GC
Simulated Distillation (Sim Dis) by GC
Flash Point by Tag Closed Cup
Synthetic Distillation Standard
Flash Point by Cleveland Open Cup
Flash Point by Pensky-Martens Closed Cup
Pour Point
Reid Vapor Pressure of Petroleum Products
Kinematic Viscosity (please refer to pages 18-19)
Aniline Point
Cetane Number of Diesel Fuel Oil
Freezing Point
Olefin Analysis by FIA
Water in Liquid Petroleum Products
Calibration of Master Viscometers & Viscosity Oil Standards
Freezing Point
Cloud Point
RON of Spark-Ignition Engine Fuel
MON of Spark-Ignition Engine Fuel
Hydrocarbon Analysis in Gasoline by GC/MS
Boiling Range by GC
Salts in Crude Oil
Phosphorus in Gasoline
Lead in Gasoline by AA
Acidity in Aviation Turbine Fuel
Li and Na in Lubricating Greases by Flame Photometer
Diesel Fuel Analysis by GC
Trace Metal in Gas Turbine Fuel by AA
Aromatics in Gasoline by GC
Total Cobalt Analysis by Potentiometric Titration
Boiling Range by GC
p-Xylene Analysis by GC
Manganese in Gasoline by AA
Density, Relative, and API Gravity of Liquids
Benzene in Motor and Aviation Gasoline
PCB Analysis by GC
Ion Chromatography
Ethylene Glycol by GC
Ion Chromatography
Water in Liquid Petroleum Products
Aromatics in Gasoline by GC
Wear Metals in Lube Oil
Nitrogen by Chemilluminescence
Oxygenates in Gasoline by GC
Wear Metals and Additives by WD-XRF
Water in Liquid Petroleum Products
Chlorine in Crude Oil by Microcoulometry
Wear Metals and Additives by ICP
Vapor Pressure of Gasoline
Trace Metals in Petroleum Coke by AA
Lead in Gasoline by X-Ray Spectroscopy
Petroleum Naphthas through n-Nonane Analysis by GC
182
Al and Si by ICP
Aromatics by SFC
Vapor-Liquid Ratio Temperature
Vapor Pressure Standards
Boiling Range Distribution by GC
MTBE Analysis by GC
Petroleum Waxes by GC
PNA Analysis by Multidimensional GC
Oil Volatility by GC
Vapor Pressure Standards
Ethanol Analysis by GC
Aromatics by GC
Oxygenates by OFID
Trace Metals by ICP
Oxygenates by Reductive Pyrolysis
Sulfur Compounds by Sulfur Selective Detection
Trace Metals by ICP
Nitrogen by Chemilluminescence
Aromatics by GC/MS
Cloud Point (Stepped Cooling Method)
Cloud Point (Linear Cooling Rate)
Cloud Point (Constant Cooling Rate)
Trace Metals by AA
Freezing Point (Auto Optical Method)
Pour Point (Auto Pressure Pulsing Method)
Pour Point (Auto Tilt Method)
Freezing Point
Pour Point (Rotational Method)
Oxygenates and Aromatics by GC/FTIR
PCBs by GC
Solvent Red 164 Dye Concentration in Diesel Fuels
Benzene in Spark Ignition Fuels
Oxygenates in Engine Fuels by GC
Total Olefins in Spark Ignition Engine Fuels by GC
Water in Liquid Petroleum Products
Boiling Range Distribution of Petroleum
Cold Filter Plugging Point of Diesel and Heating Fuels
Vapor Pressure
Aromatic Hydrocarbon by HPLC
Engine Oil by GC
Metals in Oil
Lube Oils by ED-XRF
Olefin Content of Gasoline by SFC
Flash Point by Abel Closed Cup
Sulfur Standards
D2622
D3120
D3246
D4294
D5453
D6334
D6445
Sulfur by WD-XRF
Sulfur by Oxidative Microcoulometry
Sulfur in Petroleum Gas by Oxidative Microcoulometry
Sulfur by ED-XRF
Sulfur by Ultraviolet Fluorescence
Sulfur in Gasoline by Wavelength
Sulfur in Gasoline by ED-XRF
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 183
ASTM Thermometers,
Test Specimens and Glassware
Test Methods
Page
ASTM Thermometers............................................................................184
Glass Apparatus for ASTM Test Methods ..........................................192
Standardized Metal Test Specimens ..................................................197
www.koehlerinstrument.com
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 184
ASTM Thermometers
Koehler is pleased to offer our customers calibrated thermometers in addition to the wide range of ASTM thermometers available. Thermometers are calibrated
to ASTM E-1 requirements in accordance with Method E-77 and are NIST traceable. Calibrated thermometers come with an ISO/IEC 17025 and ANSI/NCSL
Z-540-1 Report of Calibration. When ordering, please indicate by catalog number the thermometer(s) which meet your testing requirements.
Catalog
Number
250-000-01C
250-004-01C
250-000-01F
250-004-01F
250-000-02C
250-004-02C
250-000-02F
250-004-02F
250-000-03C
250-004-03C
250-000-03F
250-004-03F
250-000-04C
250-004-04C
250-000-04F
250-004-04F
250-000-05C
250-004-05C
250-000-05F
250-004-05F
250-000-06C
250-004-06C
250-000-06F
250-004-06F
250-000-07C
250-004-07C
250-000-07F
250-004-07F
250-000-08C
250-004-08C
250-000-08F
250-004-08F
250-000-09C
250-004-09C
250-000-09F
250-004-09F
250-000-10C
250-004-10C
250-000-10F
250-004-10F
250-000-11C
250-004-11C
250-000-11F
250-004-11F
250-000-12C
250-004-12C
250-000-12F
250-004-12F
ASTM
Designation
1C
1C
1F
1F
2C
2C
2F
2F
3C
3C
3F
3F
4C
4C
4F
4F
5C
5C
5F
5F
6C
6C
6F
6F
7C
7C
7F
7F
8C
8C
8F
8F
9C
9C
9F
9F
10C
10C
10F
10F
11C
11C
11F
11F
12C
12C
12F
12F
IP
Reference
—
—
—
—
62C
62C
62F
62F
73C
73C
73F
73F
—
—
—
—
1C
1C
1F
1F
2C
2C
2F
2F
5C
5C
—
—
6C
6C
—
—
15C
15C
15F
15F
16C
16C
16F
16F
28C
28C
28F
28F
64C
64C
64F
64F
Name
Range
Partial Immersion
–20 to +150°C
1C CERTIFIED @ ASTM specified test points of –20, 0, +50, 100, 150°C
Partial Immersion
0 to 302°F
1F CERTIFIED @ ASTM specified test points of 0, 32, 122, 212, 302°F
Partial Immersion
–5 to +300°C
2C CERTIFIED @ ASTM specified test points of 0, 75, 150, 225, 300°C
Partial Immersion
20 to 580°F
2F CERTIFIED @ ASTM specified test points of 32, 150, 300, 450, 580°F
Partial Immersion
–5 to +400°C
3C CERTIFIED @ ASTM specified test points of 0, 100, 200, 300, 370°C
Partial Immersion
20 to 760°F
3F CERTIFIED @ ASTM specified test points of 32, 200, 370, 540, 700°F
Acid Heat
–1 to +105°C
4C CERTIFIED @ ASTM specified test points of 0, 50, 100°C
Acid Heat
30 to 220°F
4F CERTIFIED @ ASTM specified test points of 32, 122, 212°F
Cloud & Pour, High
–38 to +50°C
5C CERTIFIED @ ASTM specified test points of –35, 0, +50°C
Cloud & Pour, High
–36 to +120°F
5F CERTIFIED @ ASTM specified test points of –30, +32, 120°F
Cloud & Pour, Low
–80 to +20°C
6C CERTIFIED @ ASTM specified test points of –70, –35, 0, +20°C
Cloud & Pour, Low
–112 to +70°F
6F CERTIFIED @ ASTM specified test points of –94, –30, +32, 70°F
Distillation, Low
–2 to +300°C
7C CERTIFIED @ ASTM specified test points of 0, 50, 100, 150, 200, 250, 300°C
Distillation, Low
30 to 580°F
7F CERTIFIED @ ASTM specified test points of 32, 100, 200, 300, 400, 500, 570°F
Distillation, High
–2 to +400°C
8C CERTIFIED @ ASTM specified test points of 0, 100, 200, 300, 370°C
Distillation, High
30 to 760°F
8F CERTIFIED @ ASTM specified test points of 32, 200, 370, 540, 700°F
Pensky-Martens, Low
–5 to +110°C
9C CERTIFIED @ ASTM specified test points of 0, 35, 70, 105°C
Pensky-Martens, Low
20 to 230°F
9F CERTIFIED @ ASTM specified test points of 32, 100, 160, 220°F
Pensky-Martens, High
90 to 370°C
10C CERTIFIED @ ASTM specified test points of 100, 200, 300, 370C
Pensky-Martens, High
200 to 700°F
10F CERTIFIED @ ASTM specified test points of 212, 390, 570, 700F
Open Flash
–6 to +400°C
11C CERTIFIED @ ASTM specified test points of 0, 100, 200, 300, 370°C
Open Flash
20 to 760°F
11F CERTIFIED @ ASTM specified test points of 32, 200, 370, 540, 700°F
Gravity (Density)
–20 to +102°C
12C CERTIFIED @ ASTM specified test points of –20, –10, 0, +10, 20, 30, 40, 50, 60, 70, 80, 90, 100°C
Gravity (Density)
–5 to +215°F
12F CERTIFIED @ ASTM specified test points of –5, 15, 32, 60, 85, 110, 135, 160, 185, 210°F
Koehler now offers mercury-free, liquid-in-glass thermometers that have
the performance of mercury. Please contact Koehler Customer Service
for availability of non-mercury type thermometer of interest. Please
note, not all ASTM thermometers are available as non-mercury type.
184
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 185
ASTM Thermometers
Catalog
Number
250-000-13C
250-004-13C
250-000-14C
250-004-14C
250-000-14F
250-004-14F
250-000-15C
250-004-15C
250-000-15F
250-004-15F
250-000-16C
250-004-16C
250-000-16F
250-004-16F
250-000-17C
250-004-17C
250-000-17F
250-004-17F
250-000-18C
250-004-18C
250-000-18F
250-004-18F
250-000-19C
250-004-19C
250-000-19F
250-004-19F
250-000-20C
250-004-20C
250-000-20F
250-004-20F
250-000-21C
250-004-21C
250-000-21F
250-004-21F
250-000-22C
250-004-22C
250-000-22F
250-004-22F
250-000-23C
250-004-23C
250-000-24C
250-004-24C
250-000-25C
250-004-25C
250-000-26C
250-004-26C
250-000-27C
250-004-27C
250-000-28C
250-004-28C
250-000-28F
250-004-28F
ASTM
Designation
13C
13C
14C
14C
14F
14F
15C
15C
15F
15F
16C
16C
16F
16F
17C
17C
17F
17F
18C
18C
18F
18F
19C
19C
19F
19F
20C
20C
20F
20F
21C
21C
21F
21F
22C
22C
22F
22F
23C
23C
24C
24C
25C
25C
26C
26C
27C
27C
28C
28C
28F
28F
IP
Reference
47C
47C
17C
17C
17F
17F
60C
60C
—
—
61C
61C
—
—
—
—
—
—
23C
23C
23F
23F
—
—
—
—
—
—
—
—
—
—
—
—
24C
24C
24F
24F
—
—
—
—
—
—
—
—
—
—
31C
31C
—
—
Name
Loss on Heat
13C CERTIFIED @ ASTM specified test points of 155, 163, 170°C
Paraffin Wax Melting Point
14C CERTIFIED @ ASTM specified test points of 40, 50, 60, 70, 80°C
Paraffin Wax Melting Point
14F CERTIFIED @ ASTM specified test points of 100, 120, 140, 160, 180°F
Softening Point, Low
15C CERTIFIED @ ASTM specified test points of 0, 20, 40, 60, 80°C
Softening Point, Low
15F CERTIFIED @ ASTM specified test points of 32, 70, 100, 140, 180°F
Softening Point, High
16C CERTIFIED @ ASTM specified test points of 30, 60, 90, 120, 150, 180, 200°C
Softening Point, High
16F CERTIFIED @ ASTM specified test points of 90, 140, 190, 240, 290, 340, 390°F
Saybolt Viscosity
17C CERTIFIED @ ASTM specified test points of 21, 25°C
Saybolt Viscosity
17F CERTIFIED @ ASTM specified test points of 70, 77°F
Saybolt Viscosity & Reid Vapor
18C CERTIFIED @ ASTM specified test points of 38, 41°C
Saybolt Viscosity & Reid Vapor
18F CERTIFIED @ ASTM specified test points of 100, 107°F
Saybolt Viscosity
19C CERTIFIED @ ASTM specified test points of 50, 54°C
Saybolt Viscosity
19F CERTIFIED @ ASTM specified test points of 122, 130°F
Saybolt Viscosity
20C CERTIFIED @ ASTM specified test points of 60, 64°C
Saybolt Viscosity
20F CERTIFIED @ ASTM specified test points of 140, 147°F
Saybolt Viscosity
21C CERTIFIED @ ASTM specified test points of 82, 86°C
Saybolt Viscosity
21F CERTIFIED @ ASTM specified test points of 180, 187°F
Saybolt Viscosity & Oxidation Stability
22C CERTIFIED @ ASTM specified test points of 99, 102°C
Saybolt Viscosity & Oxidation Stability
22F CERTIFIED @ ASTM specified test points of 210, 212°F
Viscosity Engler
23C CERTIFIED @ ASTM specified test points of 20, 25°C
Viscosity Engler
24C CERTIFIED @ ASTM specified test points of 40, 50°C
Viscosity Engler
25C CERTIFIED @ ASTM specified test points of 95, 100°C
Stability Test of Soluble Nitro-Cellulose
26C CERTIFIED @ ASTM specified test points of 130, 135, 140°C
Turpentine Distillation
27C CERTIFIED @ ASTM specified test points of 155, 165, 175°C
Kinematic Viscosity @ 37.8C
28C CERTIFIED @ ASTM specified test points of 0, 37.8, 39°C
Kinematic Viscosity @ 100F
28F CERTIFIED @ ASTM specified test points of 32, 100, 102°F
185
Range
155 to 170°C°
38 to 82°C
100 to 180°F
–2 to +80°C
30 to 180°F
30 to 200°C
85 to 392°F
19 to 27°C
66 to 80°F
34 to 42°C
94 to 108°F
49 to 57°C
120 to 134°F
57 to 65°C
134 to 148°F
79 to 87°C
174 to 188°F
95 to 103°C
204 to 218°F
18 to 28°C
39 to 54°C
95 to 105°C
130 to 140°C
147 to 182°C
36.6 to 39.4°C
97.5 to 102.5°F
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 186
ASTM Thermometers
Catalog
Number
250-000-29C
250-004-29C
250-000-29F
250-004-29F
250-000-30F
250-004-30F
250-000-31F
250-004-31F
250-000-33C
250-004-33C
250-000-33F
250-004-33F
250-000-34C
250-004-34C
250-000-34F
250-004-34F
250-000-35C
250-004-35C
250-000-35F
250-004-35F
250-000-36C
250-004-36C
250-000-37C
250-004-37C
250-000-38C
250-004-38C
250-000-39C
250-004-39C
250-000-40C
250-004-40C
250-000-41C
250-004-41C
250-000-42C
250-004-42C
250-000-43C
250-004-43C
250-000-43F
250-004-43F
250-000-44C
250-004-44C
250-000-44F
250-004-44F
250-000-45C
250-004-45C
250-000-45F
250-004-45F
250-000-46C
250-004-46C
250-000-46F
250-004-46F
ASTM
Designation
29C
29C
29F
29F
30F
30F
31F
31F
33C
33C
33F
33F
34C
34C
34F
34F
35C
35C
35F
35F
36C
36C
37C
37C
38C
38C
39C
39C
40C
40C
41C
41C
42C
42C
43C
43C
43F
43F
44C
44C
44F
44F
45C
45C
45F
45F
46C
46C
46F
46F
IP
Reference
34C
34C
—
—
32F
32F
—
—
20C
20C
—
—
21C
21C
—
—
59C
59C
—
—
—
—
77C
77C
78C
78C
79C
79C
80C
80C
81C
81C
82C
82C
65C
65C
65F
65F
29C
29C
29F
29F
30C
30C
30F
30F
66C
66C
66F
66F
Name
Kinematic Viscosity @ 54.4C
29C CERTIFIED @ ASTM specified test points of 0, 54.4, 55°C
Kinematic Viscosity @ 130F
29F CERTIFIED @ ASTM specified test points of 32, 130, 132°F
Kinematic Viscosity @ 210F
30F CERTIFIED @ ASTM specified test points of 32, 210, 212°F
Reid Vapor
31F CERTIFIED @ ASTM specified test points of –20, +32, 100°F
Aniline Point
33C CERTIFIED @ ASTM specified test points of –35, –20, 0, +20, 40°C
Aniline Point
33F CERTIFIED @ ASTM specified test points of –31, –4, +32, 68, 104°F
Aniline Point
34C CERTIFIED @ ASTM specified test points of 25, 45, 65, 85, 100°C
Aniline Point
34F CERTIFIED @ ASTM specified test points of 77, 113, 149, 185, 212°F
Aniline Point
35C CERTIFIED @ ASTM specified test points of 100, 120, 140, 160, 170°C
Aniline Point
35F CERTIFIED @ ASTM specified test points of 212, 250, 285, 320, 338°F
Titer Test
36C CERTIFIED @ ASTM specified test points of 0, 15, 30, 45, 65°C
Solvents Distillation
37C CERTIFIED @ ASTM specified test points of 0, 15, 30, 50°C
Solvents Distillation
38C CERTIFIED @ ASTM specified test points of 25, 40, 55, 75C
Solvents Distillation
39C CERTIFIED @ ASTM specified test points of 50, 65, 80, 100°C
Solvents Distillation
40C CERTIFIED @ ASTM specified test points of 75, 90, 105, 125°C
Solvents Distillation
41C CERTIFIED @ ASTM specified test points of 100, 115, 130, 150°C
Solvents Distillation
42C CERTIFIED @ ASTM specified test points of 100, 150, 200, 250°C
Kinematic Viscosity
43C CERTIFIED @ ASTM specified test points of –50, –45, –40, –35, 0°C
Kinematic Viscosity
43F CERTIFIED @ ASTM specified test points of –60, –50, –40, –30, +32°F
Kinematic Viscosity @ 20C
44C CERTIFIED @ ASTM specified test points of 0, 20, 21°C
Kinematic Viscosity @ 68F
44F CERTIFIED @ ASTM specified test points of 32, 68, 70°F
Kinematic Viscosity @ 25C
45C CERTIFIED @ ASTM specified test points of 0, 25, 26°C
Kinematic Viscosity @ 77F
45F CERTIFIED @ ASTM specified test points of 32, 77, 79°F
Kinematic Viscosity @ 50C
46C CERTIFIED @ ASTM specified test points of 0, 50, 51°C
Kinematic Viscosity @ 122F
46F CERTIFIED @ ASTM specified test points of 32, 122, 124°F
Range
52.6 to 55.4°C
127.5 to 132.5°F
207.5 to 212.5°F
–30 to +120°F
–38 to +42°C
–36.5 to +107.5°F
25 to 105°C
77 to 221°F
90 to 170°C
194 to 338°F
–2 to +68°C
–2 to +52°C
24 to 78°C
48 to 102°C
72 to 126°C
98 to 152°C
95 to 255°C
–51.6 to –34°C
–61 to –29°F
18.5 to 21.5°C
66.5 to 71.5°F
23.6 to 26.4°C
74.5 to 79.5°F
48.6 to 51.4°C
119.5 to 124.5°F
Koehler now offers mercury-free, liquid-in-glass thermometers that have
the performance of mercury. Please contact Koehler Customer Service
for availability of non-mercury type thermometer of interest. Please
note, not all ASTM thermometers are available as non-mercury type.
186
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 187
ASTM Thermometers
Catalog
Number
250-000-47C
250-004-47C
250-000-47F
250-004-47F
250-000-48C
250-004-48C
250-000-48F
250-004-48F
250-000-49C
250-004-49C
250-000-50F
250-004-50F
250-000-51F
250-004-51F
250-000-52C
250-004-52C
250-000-53C
250-004-53C
250-000-54C
250-004-54C
250-000-54F
250-004-54F
250-000-56C
250-004-56C
250-000-56F
250-004-56F
250-000-57C
250-004-57C
250-000-57F
250-004-57F
250-000-58C
250-004-58C
250-000-58F
250-004-58F
250-000-59C
250-004-59C
250-000-59F
250-004-59F
250-000-60C
250-004-60C
250-000-60F
250-004-60F
250-000-61C
250-004-61C
250-000-61F
250-004-61F
250-000-62C
250-004-62C
250-000-62F
250-004-62F
ASTM
Designation
47C
47C
47F
47F
48C
48C
48F
48F
49C
49C
50F
50F
51F
51F
52C
52C
53C
53C
54C
54C
54F
54F
56C
56C
56F
56F
57C
57C
57F
57F
58C
58C
58F
58F
59C
59C
59F
59F
60C
60C
60F
60F
61C
61C
61F
61F
62C
62C
62F
62F
IP
Reference
35C
35C
35F
35F
90C
90C
90F
90F
—
—
—
—
—
—
—
—
—
—
18C
18C
18F
18F
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
63C
63C
—
—
—
—
—
—
Name
Range
Kinematic Viscosity @ 60C
58.6 to 61.4°C
47C CERTIFIED @ ASTM specified test points of 0, 60, 61°C
Kinematic Viscosity @ 140F
137.5 to 142.5°F
47F CERTIFIED @ ASTM specified test points of 32, 140, 142°F
Kinematic Viscosity @ 82.2C
80.6 to 83.4°C
48C CERTIFIED @ ASTM specified test points of 0, 82.2, 83°C
Kinematic Viscosity @ 180F
177.5 to 182.5°F
48F CERTIFIED @ ASTM specified test points of 32, 180, 182°F
Stormer Viscosity
20 to 70°C
49C CERTIFIED @ ASTM specified test points of 20, 35, 50, 70°C
Gas Calorimeter Inlet
54 to 101°F
50F CERTIFIED @ ASTM specified test points of 55, 60, 65, 70, 75, 80, 85, 90, 95, 100°F
Gas Calorimeter Outlet
69 to 116°F
51F CERTIFIED @ ASTM specified test points of 70, 75, 80, 85, 90, 95, 100, 105, 110, 115°F
Butadiene Boiling Point
–10 to +5°C
52C CERTIFIED @ ASTM specified test points of –10, 0, +5°C
Benzene Freezing Pt
–0.6 to +10.4°C
53C CERTIFIED @ ASTM specified test points of 0, 5, 10°C
Congealing Point
20 to 100.6°C
54C CERTIFIED @ ASTM specified test points of 20, 50, 75, 100°C
Congealing Point
68 to 213°F
54F CERTIFIED @ ASTM specified test points of 70, 120, 170, 210°F
Bomb Calorimeter
19 to 35°C
56C CERTIFIED @ ASTM specified test points of 19, 21, 23, 25, 27, 29, 31°C
Bomb Calorimeter
66 to 95°F
56F CERTIFIED @ ASTM specified test points of 66, 70, 74, 78, 82, 88, 92, 95°F
Tag Closed Tester Low Range
–20 to +50°C
57C CERTIFIED @ ASTM specified test points of –20, 0, 25, +50°C
Tag Closed Tester Low Range
–4 to +122°F
57F CERTIFIED @ ASTM specified test points of –3, +32, 77, 122°F
Tank Gauging
–34 to +49°C
58C CERTIFIED @ ASTM specified test points of –30, 0, +25, 45°C
Tank Gauging
–30 to +120°F
58F CERTIFIED @ ASTM specified test points of –20, +32, 80, 120°F
Tank Gauging
–18 to +82°C
59C CERTIFIED @ ASTM specified test points of 0, 25, 55, 80°C
Tank Gauging
0 to 180°F
59F CERTIFIED @ ASTM specified test points of 32, 80, 130, 180°F
Tank Gauging
77 to 260°C
60C CERTIFIED @ ASTM specified test points of 100, 175, 255°C
Tank Gauging
170 to 500°F
60F CERTIFIED @ ASTM specified test points of 212, 350, 490°F
Petrolatum Melting Point
32 to 127°C
61C CERTIFIED @ ASTM specified test points of 40, 60, 80, 100, 120°C
Petrolatum Melting Point
90 to 260°F
61F CERTIFIED @ ASTM specified test points of 100, 150, 200, 250°F
Reference Standard
–38 to +2°C
62C CERTIFIED @ ASTM specified test points of –37, –30, –20, –10, 0°C
Reference Standard
–36 to +35°F
62F CERTIFIED @ ASTM specified test points of –35, –15, 0, +15, 32°F
187
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 188
ASTM Thermometers
Catalog
Number
250-000-63C
250-004-63C
250-000-63F
250-004-63F
250-000-64C
250-004-64C
250-000-64F
250-004-64F
250-000-65C
250-004-65C
250-000-65F
250-004-65F
250-000-66C
250-004-66C
250-000-66F
250-004-66F
250-000-67C
250-004-67C
250-000-67F
250-004-67F
250-000-68C
250-004-68C
250-000-68F
250-004-68F
250-000-69C
250-004-69C
250-000-69F
250-004-69F
250-000-70C
250-004-70C
250-000-70F
250-004-70F
250-000-71C
250-004-71C
250-000-71F
250-004-71F
250-000-72C
250-004-72C
250-000-72F
250-004-72F
250-000-73C
250-004-73C
250-000-73F
250-004-73F
250-000-74C
250-004-74C
250-000-74F
250-004-74F
250-000-75F
250-004-75F
ASTM
Designation
63C
63C
63F
63F
64C
64C
64F
64F
65C
65C
65F
65F
66C
66C
66F
66F
67C
67C
67F
67F
68C
68C
68F
68F
69C
69C
69F
69F
70C
70C
70F
70F
71C
71C
71F
71F
72C
72C
72F
72F
73C
73C
73F
73F
74C
74C
74F
74F
75F
75F
IP
Reference
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
72C
72C
72F
72F
67C
67C
67F
67F
68C
68C
68F
68F
69C
69C
69F
69F
—
—
Name
Reference Standard
63C CERTIFIED @ ASTM specified test points of –7, 0, +10, 20, 30°C
Reference Standard
63F CERTIFIED @ ASTM specified test points of 20, 32, 50, 70, 88°F
Reference Standard
64C CERTIFIED @ ASTM specified test points of 0, 25, 35, 45, 55°C
Reference Standard
64F CERTIFIED @ ASTM specified test points of 32, 80, 95, 115, 130°F
Reference Standard
65C CERTIFIED @ ASTM specified test points of 0, 50, 60, 70, 80°C
Reference Standard
65F CERTIFIED @ ASTM specified test points of 32, 125, 145, 160, 175°F
Reference Standard
66C CERTIFIED @ ASTM specified test points of 0, 75, 85, 95, 105°C
Reference Standard
66F CERTIFIED @ ASTM specified test points of 32, 168, 185, 200, 220°F
Reference Standard
67C CERTIFIED @ ASTM specified test points of 0, 100, 110, 130, 150°C
Reference Standard
67F CERTIFIED @ ASTM specified test points of 32, 205, 240, 275, 310°F
Reference Standard
68C CERTIFIED @ ASTM specified test points of 0, 150, 170, 190, 205°C
Reference Standard
68F CERTIFIED @ ASTM specified test points of 32, 300, 340, 370, 400°F
Reference Standard
69C CERTIFIED @ ASTM specified test points of 0, 200, 235, 270, 305°C
Reference Standard
69F CERTIFIED @ ASTM specified test points of 32, 400, 460, 520, 580°F
Reference Standard
70C CERTIFIED @ ASTM specified test points of 0, 300, 335, 370, 400°C
Reference Standard
70F CERTIFIED @ ASTM specified test points of 32, 570, 640, 700, 760°F
Oil in Wax
71C CERTIFIED @ ASTM specified test points of –35, –18, 0, +20°C
Oil in Wax
71F CERTIFIED @ ASTM specified test points of –30, 0, +32, 70°F
Kinematic Viscosity @ –17.8C
72C CERTIFIED @ ASTM specified test points of –19, –17.8, 0°C
Kinematic Viscosity @ 0F
72F CERTIFIED @ ASTM specified test points of –2, 0, +32°F
Kinematic Viscosity @ –40C
73C CERTIFIED @ ASTM specified test points of –41, –40, 0°C
Kinematic Viscosity @ –40F
73F CERTIFIED @ ASTM specified test points of –42, –40, +32°F
Kinematic Viscosity @ –53.9C
74C CERTIFIED @ ASTM specified test points of –55, –53.9, 0°C
Kinematic Viscosity @ –65F
74F CERTIFIED @ ASTM specified test points of –67, –65, +32°F
Coolant Freezing Point
75F CERTIFIED @ ASTM specified test points of –35, 0, +32°F
Range
–8 to +32°C
18 to 89°F
25 to 55°C
77 to 131°F
50 to 80°C
122 to 176°F
75 to 105°C
167 to 221°F
95 to 155°C
203 to 311°F
145 to 205°C
293 to 401°F
195 to 305°C
383 to 581°F
295 to 405°C
563 to 761°F
–37 to +21°C
–35 to +70°F
–19.4 to –16.6°C
–2.5 to +2.5°F
–41.4 to –38.6°C
–42.5 to –37.5°F
–55.4 to –52.6°C
–67.5 to –62.5°F
–35 to +35°F
Koehler now offers mercury-free, liquid-in-glass thermometers that have
the performance of mercury. Please contact Koehler Customer Service
for availability of non-mercury type thermometer of interest. Please
note, not all ASTM thermometers are available as non-mercury type.
188
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 189
ASTM Thermometers
Catalog
Number
250-000-76F
250-004-76F
250-000-77F
250-004-77F
250-000-78F
250-004-78F
250-000-79F
250-004-79F
250-000-80F
250-004-80F
250-000-81F
250-004-81F
250-000-82C
250-004-82C
250-000-82F
250-004-82F
250-000-83C
250-004-83C
250-000-83F
250-004-83F
250-000-84C
250-004-84C
250-000-84F
250-004-84F
250-000-85C
250-004-85C
250-000-85F
250-004-85F
250-000-86C
250-004-86C
250-000-86F
250-004-86F
250-000-87C
250-004-87C
250-000-87F
250-004-87F
250-000-88C
250-004-88C
250-000-88F
250-004-88F
250-000-89C
250-004-89C
250-000-90C
250-004-90C
250-000-91C
250-004-91C
250-000-92C
250-004-92C
250-000-93C
250-004-93C
ASTM
Designation
76F
76F
77F
77F
78F
78F
79F
79F
80F
80F
81F
81F
82C
82C
82F
82F
83C
83C
83F
83F
84C
84C
84F
84F
85C
85C
85F
85F
86C
86C
86F
86F
87C
87C
87F
87F
88C
88C
88F
88F
89C
89C
90C
90C
91C
91C
92C
92C
93C
93C
IP
Reference
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Name
Coolant Freezing Point
76F CERTIFIED @ ASTM specified test points of –65, –30, +32°F
Saybolt Viscosity
77F CERTIFIED @ ASTM specified test points of 250, 260°F
Saybolt Viscosity
78F CERTIFIED @ ASTM specified test points of 300, 310°F
Saybolt Viscosity
79F CERTIFIED @ ASTM specified test points of 350, 360°F
Saybolt Viscosity
80F CERTIFIED @ ASTM specified test points of 400, 410°F
Saybolt Viscosity
81F CERTIFIED @ ASTM specified test points of 450, 460°F
Fuel Rating, Engine
82C CERTIFIED @ ASTM specified test points of 0, 50, 100°C
Fuel Rating, Engine
82F CERTIFIED @ ASTM specified test points of 32, 100, 200°F
Fuel Rating, Air
83C CERTIFIED @ ASTM specified test points of 25, 70°C
Fuel Rating, Air
83F CERTIFIED @ ASTM specified test points of 85, 135°F
Fuel Rating, Orifice
84C CERTIFIED @ ASTM specified test points of 30, 80°C
Fuel Rating, Orifice
84F CERTIFIED @ ASTM specified test points of 100, 150°F
Fuel Rating, Surge
85C CERTIFIED @ ASTM specified test points of 50, 150°C
Fuel Rating, Surge
85F CERTIFIED @ ASTM specified test points of 150, 250°F
Fuel Rating, Mix
86C CERTIFIED @ ASTM specified test points of 100, 175°C
Fuel Rating, Mix
86F CERTIFIED @ ASTM specified test points of 225, 325°F
Fuel Rating, Coolant
87C CERTIFIED @ ASTM specified test points of 160, 200°C
Fuel Rating, Coolant
87F CERTIFIED @ ASTM specified test points of 300, 400°F
Vegetable Oil Flash
88C CERTIFIED @ ASTM specified test points of 40, 100, 150, 200°C
Vegetable Oil Flash
88F CERTIFIED @ ASTM specified test points of 110, 212, 300, 392°F
Solidification Point
89C CERTIFIED @ ASTM specified test points of –20, –10, 0, +10°C
Solidification Point
90C CERTIFIED @ ASTM specified test points of 0, 10, 20, 30°C
Solidification Point
91C CERTIFIED @ ASTM specified test points of 20, 30, 40, 50°C
Solidification Point
92C CERTIFIED @ ASTM specified test points of 40, 50, 60, 70°C
Solidification Point
93C CERTIFIED @ ASTM specified test points of 60, 70, 80, 90°C
189
Range
–65 to +5°F
245 to 265°F
295 to 315°F
345 to 365°F
395 to 415°F
445 to 465°F
–15 to +105°C
0 to 220°F
15 to 70°C
60 to 160°F
25 to 80°C
75 to 175°F
40 to 150°C
100 to 300°F
95 to 175°C
200 to 350°F
150 to 205°C
300 to 400°F
10 to 200°C
50 to 392°F
–20 to +10°C
0 to 30°C
20 to 50°C
40 to 70°C
60 to 90°C
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 190
ASTM Thermometers
Catalog
Number
250-000-94C
250-004-94C
250-000-95C
250-004-95C
250-000-96C
250-004-96C
250-000-97C
250-004-97C
250-000-97F
250-004-97F
250-000-98C
250-004-98C
250-000-98F
250-004-98F
250-000-99C
250-004-99C
250-000-99F
250-004-99F
250-000-100C
250-004-100C
250-000-101C
250-004-101C
250-000-102C
250-004-102C
250-000-103C
250-004-103C
250-000-104C
250-004-104C
250-000-105C
250-004-105C
250-000-106C
250-004-106C
250-000-107C
250-004-107C
250-000-108F
250-004-108F
250-000-109F
250-004-109F
250-000-110C
250-004-110C
250-000-110F
250-004-110F
250-000-111C
250-004-111C
250-000-112C
250-004-112C
250-000-113C
250-004-113C
250-000-113F
250-004-113F
ASTM
Designation
94C
94C
95C
95C
96C
96C
97C
97C
97F
97F
98C
98C
98F
98F
99C
99C
99F
99F
100C
100C
101C
101C
102C
102C
103C
103C
104C
104C
105C
105C
106C
106C
107C
107C
108F
108F
109F
109F
110C
110C
110F
110F
111C
111C
112C
112C
113C
113C
113F
113F
IP
Reference
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
83C
83C
84C
84C
85C
85C
86C
86C
87C
87C
88C
88C
—
—
—
—
93C
93C
—
—
—
—
—
—
89C
89C
89F
89F
Name
Solidification Point
94C CERTIFIED @ ASTM specified test points of 80, 90, 100, 110°C
Solidification Point
95C CERTIFIED @ ASTM specified test points of 100, 110, 120, 130°C
Solidification Point
96C CERTIFIED @ ASTM specified test points of 120, 130, 140, 150°C
Tank Gauging
97C CERTIFIED @ ASTM specified test points of –15, 0, +20, 45°C
Tank Gauging
97F CERTIFIED @ ASTM specified test points of 0, 32, 70, 110°F
Tank Gauging
98C CERTIFIED @ ASTM specified test points of 20, 40, 60, 80°C
Tank Gauging
98F CERTIFIED @ ASTM specified test points of 60, 100, 140, 180°F
Weathering Test
99C CERTIFIED @ ASTM specified test points of –46, –32, –18, 0°C
Weathering Test
99F CERTIFIED @ ASTM specified test points of –50, –25, 0, +32°F
Solidification Point
100C CERTIFIED @ ASTM specified test points of 145, 165, 185, 205°C
Solidification Point
101C CERTIFIED @ ASTM specified test points of 200, 250, 300°C
Solvents Distillation
102C CERTIFIED @ ASTM specified test points of 125, 140, 155, 175°C
Solvents Distillation
103C CERTIFIED @ ASTM specified test points of 150, 165, 180, 200°C
Solvents Distillation
104C CERTIFIED @ ASTM specified test points of 175, 190, 205, 225°C
Solvents Distillation
105C CERTIFIED @ ASTM specified test points of 200, 215, 230, 250°C
Solvents Distillation
106C CERTIFIED @ ASTM specified test points of 225, 240, 255, 275°C
Solvents Distillation
107C CERTIFIED @ ASTM specified test points of 250, 265, 280, 300°C
Saybolt Viscosity
108F CERTIFIED @ ASTM specified test points of 275, 285°F
Saybolt Viscosity
109F CERTIFIED @ ASTM specified test points of 325, 335°F
Kinematic Viscosity @ 135C
110C CERTIFIED @ ASTM specified test points of 0, 135, 136°C
Kinematic Viscosity @ 275F
110F CERTIFIED @ ASTM specified test points of 32, 275, 277°F
Tar Acid Distillation
111C CERTIFIED @ ASTM specified test points of 170, 200, 250°C
Solidification Benzene
112C CERTIFIED @ ASTM specified test points of 0, 4, 5, 6°C
Bituminous Materials Softening Point
113C CERTIFIED @ ASTM specified test points of 0, 50, 100, 150, 175°C
Bituminous Materials Softening Point
113F CERTIFIED @ ASTM specified test points of 32, 122, 212, 302, 347°F
Range
80 to 110°C
100 to 130°C
120 to 150°C
–18 to +49°C
0 to 120°F
16 to 82°C
60 to 180°F
–50 to +5°C
–58 to +41°F
145 to 205°C
195 to 305°C
123 to 177°C
148 to 202°C
173 to 227°C
198 to 252°C
223 to 277°C
248 to 302°C
270 to 290°F
320 to 340°F
133.6 to 136.4°C
272.5 to 277.5°F
170 to 250°C
4 to 6°C
–1 to +175°C
30 to 350°F
Koehler now offers mercury-free, liquid-in-glass thermometers that have
the performance of mercury. Please contact Koehler Customer Service
for availability of non-mercury type thermometer of interest. Please
note, not all ASTM thermometers are available as non-mercury type.
190
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 191
ASTM Thermometers
Catalog
Number
250-000-114C
250-004-114C
250-000-114F
250-004-114F
250-000-115C
250-000-116C
250-004-116C
250-000-117C
250-004-117C
250-000-118C
250-004-118C
250-000-118F
250-004-118F
250-000-119C
250-004-119C
250-000-119F
250-004-119F
250-000-120C
250-004-120C
250-000-121C
250-004-121C
250-000-122C
250-004-122C
250-000-123C
250-004-123C
250-000-124C
250-004-124C
250-000-125C
250-004-125C
250-000-126C
250-004-126C
250-000-126F
250-004-126C
250-000-127C
250-004-127C
250-000-128C
250-004-128C
250-000-128F
250-004-128F
250-000-129C
250-004-129C
250-000-129F
250-004-129F
250-000-130C
250-004-130C
250-000-130F
250-004-130F
250-000-132C
250-004-132C
ASTM
Designation
114C
114C
114F
114F
115C
116C
116C
117C
117C
118C
118C
118F
118F
119C
119C
119F
119F
120C
120C
121C
121C
122C
122C
123C
123C
124C
124C
125C
125C
126C
126C
126F
126F
127C
127C
128C
128C
128F
128F
129C
129C
129F
129F
130C
130C
130F
130F
132C
132C
IP
Reference
14C
14C
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
92C
92C
32C
32C
94C
94C
95C
95C
96C
96C
97C
97C
71C
71C
71F
71F
99C
99C
33C
33C
33F
33F
36C
36C
36F
36F
—
—
—
—
—
—
Name
Range
Aviation Fuel Freezing Point
–80 to +20°C
114C CERTIFIED @ ASTM specified test points of –75, –60, –40, 0°C
Aviation Fuel Freezing Point
–112 to +70°F
114F CERTIFIED @ ASTM specified test points of –103, –76, –40, +32°F
Beckman Differential
0 to 6°C CERTIFICATION DOES NOT APPLY
Bomb Colorimeter
18.9 to 25.1C°
116C CERTIFIED @ ASTM specified test points of 19, 20, 21, 22, 23, 24, 25°C
Bomb Calorimeter
23.9 to 30.1°C
117C CERTIFIED @ ASTM specified test points of 24, 25, 26, 27, 28, 29, 30°C
Kinematic Viscosity @ 30C
28.6 to 31.4°C
118C CERTIFIED @ ASTM specified test points of 0, 30, 31°C
Kinematic Viscosity @ 86F
83.5 to 88.5°F
118F CERTIFIED @ ASTM specified test points of 32, 86, 88°F
Coolant Freezing Point
–38.3 to –30°C
119C CERTIFIED @ ASTM specified test points of –38, –30, 0°C
Coolant Freezing Point
–37 to –22°F
119F CERTIFIED @ ASTM specified test points of –36, –22, +32°F
Kinematic Viscosity @ 40C
38.6 to 41.4°C
120C CERTIFIED @ ASTM specified test points of 0, 40, 41°C
Kinematic Viscosity @ 100C
98.6 to 101.4°C
121C CERTIFIED @ ASTM specified test points of 0, 100, 101°C
Brookfield Viscosity
–45 to –35°C
122C CERTIFIED @ ASTM specified test points of –45, –40, -35°C
Brookfield Viscosity
–35 to –25°C
123C CERTIFIED @ ASTM specified test points of –35, –30, -25°C
Brookfield Viscosity
–25 to –15°C
124C CERTIFIED @ ASTM specified test points of –25, –20, –15°C
Brookfield Viscosity
–15 to –5°C
125C CERTIFIED @ ASTM specified test points of –15, –10, –5°C
Kinematic Viscosity @ –26.1C
–27.4 to –24.6°C
126C CERTIFIED @ ASTM specified test points of –27, -26.1, 0°C
Kinematic Viscosity @ –15F
–17.5 to –12.5°F
126F CERTIFIED @ ASTM specified test points of –17, –15, +32°F
Kinematic Viscosity @ -20C
–21.4 to –18.6°C
127C CERTIFIED @ ASTM specified test points of –21, –20, 0°C
Kinematic Viscosity @ 0C
–1.4 to +1.4°C
128C CERTIFIED @ ASTM specified test points of 0, 1°C
Kinematic Viscosity @ 32F
29.5 to 34.5°F
128F CERTIFIED @ ASTM specified test points of 32, 34°F
Kinematic Viscosity @ 93.3C
91.6 to 94.4°C
129C CERTIFIED @ ASTM specified test points of 0, 93.3, 94°C
Kinematic Viscosity @ 200F
197.5 to 202.5°F
129F CERTIFIED @ ASTM specified test points of 32, 200, 202°F
Tank Gauging
–7 to +105°C
130C CERTIFIED @ ASTM specified test points of 0, 35, 70, 105°C
Tank Gauging
20 to 220°F
130F CERTIFIED @ ASTM specified test points of 32, 100, 160, 220°F
Kinematic Viscosity @ 150C
148.6 to 151.4°C
132C CERTIFIED @ ASTM specified test points of 0, 150, 151°C
191
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 192
Glass Apparatus for ASTM Test Methods
C70 Determination of the Percentage of Voids and
Surface Moisture in Fine Aggregates
K00C70
Specific Gravity Flask, Chapman, graduated at 200mL
and 375-450mL
C128 Determination of Specific Gravity of Hydraulic Cement,
Sand, Powdered Materials
K0C128
Specific Gravity Flask, Le Chatelier, 250mL, 17mL Bulb,
Graduated Neck
C135 Determination of Specific Gravity of Pigments,
Drying Oils, Varnishes, Resins, etc.
KD0C135-10 Pycnometer, 10mL, with Thermometer and Cap
KD0C135-25 Pycnometer, 25mL, with Thermometer and Cap
KD0C135-50 Pycnometer, 50mL, with Thermometer and Cap
KD0C135-100 Pycnometer, 100mL, with Thermometer and Cap
C188 Determination of Specific Gravity of Hydraulic Cement,
Sand, Other Powdered Materials
K0C128
Specific Gravity Flask, Le Chatelier, 250mL, 17mL Bulb,
Graduated Neck
D20 Distillation of Bituminous Products
K00D20-300 Flask, Distillation, 300mL, Side Arm, 10mm ID x 220mm
K00D20-500 Flask, Distillation, 500mL, Side Arm, 10mm ID x 220mm
D29 Analysis of Dry Shellac and Shellac Varnishes
K00D29-125 Iodine Flask, 125mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-250 Iodine Flask, 250mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-300 Iodine Flask, 300mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-500 Iodine Flask, 500mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-1000 Iodine Flask, 1000mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
D70 Specific Gravity and Density of Semi-Solid Bituminous Materials
K00D70
Pycnometer Bottle, 24-30mL, Uncalibrated
D115 Determination of Specific Gravity of Solid (Bituminous) Materials,
Asphalt Cements, and Soft Tar Pitches
K0D115-750 Specific Gravity Flask, 750mL, w/Capillary Stem and Cap
K0D115-750 Specific Gravity Flask, 1000mL, w/Capillary Stem and Cap`
D153 Determination of Specific Gravity of Pigments, Drying Oils,
Varnishes, Resins, etc.
K0C135-10
Pycnometer, 10mL, with Thermometer and Cap
K0C135-25
Pycnometer, 25mL, with Thermometer and Cap
K0C135-50
Pycnometer, 50mL, with Thermometer and Cap
K0C135-100 Pycnometer, 100mL, with Thermometer and Cap
D215 Determination of Carbon Dioxide and Sulfur Dioxide in Carbonates
K0D215
Alkalimeter, Knorr, 250mL Flask, S/T 24/40 and S/T 16
D297 Direct Determination of Isoprene Polymer Using Heating Mantles.
K0D297
Rubber Distillation System consisting of 500mL
Steam Generating Flask, 100mL Digestion Flask,
Claisen Head, Spray Bulb, Condensing Adapter,
two 500mL Receiving Flasks, and
Condenser (supplied without heat mantles)
D301 Determination of Consistency of Soluble Nitrocellulose
by Falling Ball Method
K0D301
Falling Ball Viscosity Tube, 1" x 14", graduated 10" apart,
with 5 Steel Balls, .312" OD
D322 Determination of Dilution in Crankcase Oil
K0D322-5
Distillation Receiver, S/T 24/40,
graduated 5mL in 0.1mL divisions
K0D322-12
Distillation Receiver, S/T 24/40,
graduated 12.5mL x 0.1 divisions
D369 Determination of Specific Gravity
K0D369-1
Specific Gravity Bottle, Gas-Lussac, 1mL, Unadjusted
K0D369-2
Specific Gravity Bottle, Gas-Lussac, 2mL, Unadjusted
K0D369-5
Specific Gravity Bottle, Gas-Lussac, 5mL, Unadjusted
K0D369-10
Specific Gravity Bottle, Gas-Lussac, 10mL, Unadjusted
D402 Distillation of Cut-Back Asphaltic (Bituminous) Products
K0D402-F
Flask, Distillation, 500mL, Side arm 13x220mm
K0D402-C
Condenser, Liebig, Plain, 300mm
K0D402-A
Adapter, Glass, 105 Degree, 18mm ID x 5mm ID
D422 Soil Testing Hydrometer Cylinders
K0D422-1000 Hydrometer Cylinder, 1000mL TC, 460mm tall
K0D422-1205 Hydrometer Cylinder, graduated 1130 and 1205mL, 460mm tall
D453 Determination of Tar Acid
K0D453
Separatory Funnel, Tar Acid, S/T 19 Stopper,
2mm Stopcock, Graduated Stem between Bulbs,
65 to 100mL in 0.2mL divisions
D555 Iodine Determination
K00D29-125 Iodine Flask, 125mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-250 Iodine Flask, 250mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-300 Iodine Flask, 300mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-500 Iodine Flask, 500mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-1000 Iodine Flask, 100mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
D565 Carbonizable Substances in White Mineral Oil
K0D565
Test Tube, Ground Stopper, 15x140, graduated 5 and 10mL
D612 Carbonizable Substances in Parafin Wax
K0D565
Test Tube, Ground Stopper, 15x140, graduated 5 and 10mL
D789 Determination of Relative Viscosity of Polymer Solution
in Formic Acid Solution
K0D789
Viscometry Apparatus, consisting of 25mL Pipette,
50mL Flask with S/T 19/22 joints, and Pipette Adapter
192
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 193
Glass Apparatus for ASTM Test Methods
D848 Acid Wash Color of Industrial Aromatic Hydrocarbons
K0D848-A
Sample Bottle, 1 ounce capacity, flat bottom, square,
glass stoppered and graduated at 7mL and 28mL
K0D848-B
Individual Color Standard Bottle, 1 ounce capacity,
flat bottom, square, glass stoppered,
with a Specified number (0-14)
K0D848-C
Set of Fifteen (15) Color Standard Bottles
numbered 0-14, empty
K0D848-D
Individual Color Standard Bottle,
filled with specific number solution
K0D848-E
Set of Fifteen(15) Color Standard bottles
(0-14) filled
K0D848-F
Color Standard Set with Case,
lighted white plexiglass, full set of color standards
sealed in bottles, and two sample bottles
KD1018-D-1
KD1018-D-2
KD1018-D-3
KD1018-E
KD1018-F
D854 Determination of Specific Gravity
K0D369-1
Specific Gravity Bottle, Gas-Lussac, 1mL, Unadjusted
K0D369-2
Specific Gravity Bottle, Gas-Lussac, 2mL, Unadjusted
K0D369-5
Specific Gravity Bottle, Gas-Lussac, 5mL, Unadjusted
K0D369-10
Specific Gravity Bottle, Gas-Lussac, 10mL, Unadjusted
D1091 Phosphorus Lubricating Oils s in And Additives
KD1091
Flask, Kjeldahl, Digestion, 300mL, with Ground Glass Stopper
D888 Determination of Dissolved Oxygen in Water
K0D888
Gas Collecting Tube, McLean type, 500mL, 3mm Stopcocks,
graduated 2mL on Tube Ends
D1120 Determination of Equilibrium Boiling Point of Engine Antifreezes
Miscible With Water
KD1120
Distillation Apparatus, 100mL Flask,
200mm Condenser, S/T 19/38
D1065 Determination of Unsaponifiable Matter In Gum and Wood Rosin
KD1065
Extraction Apparatus, Ether, S/T 24/40,
400mm Condenser, 250mL Flask
D1072 Total Sulfur in Fuel Gases
KD1072-B
Burner, S/T 14/10 Joint, Gas
KD1266-C
Chimney, S/T 14/10 and S/T 24/40 Joints
KD1266-A
Absorber, S/T 24/40 Joints, Parallel Chambers, AU Shape
KD1266-ST
Spray Trap, S/T 24/40 Joint, 65mm OD
D1093 Centrifuge Tube, 100mL
K00D96-8
Centrifuge Tube, Conical, A8-Inch (203mm), 100mL
D889 Determination of Volatile Oil in Rosin
K0D889
Distillation Receiver, 5mL in 0.1mL divisions, S/T 24/40
D1168 Testing Hydrocarbon Waxes for Electrical Insulation
KD1168
Dilatometer, 0-2mL in 0.02mL divisions,
S/T 14/20 Joint, 2mm Stopcock
D891 Determination of Specific Gravity of Liquid Chemicals, Halogenated
Organic Solvents,Ethylene Glycols, Propylene Glycols
K0D891-25
Specific Gravity Bottle for Volatile Liquids, 25mL, Jacketed
K0D891-50
Specific Gravity Bottle for Volatile Liquids, 50mL, Jacketed
D1173 Test For Foaming Properties of Surface-Active Agents
KD1173
Pour Foam Test Apparatus, Ross-Miles, 200mL Pipette,
Receiver graduated at 50mL and 250mL, Teflon Stopcocks,
2mm and 6mm Bore, Jacketed
D914 Testing Ethylcellulose and Methylcellulose
K0D914
Apparatus for Testing Ethylcellulose
D1217 Density and Relative Density of Liquids By Bingham Pycnometer
KD1217-P
Pycnometer, Bingham type, Stoppered,
25mL 1.0 - 1.1mm neck
KD1217-PC
Pycnometer Cleaning Apparatus, Hot Chromic Acid,
consisting of 3-way Stopcock with Joint Inside Chamber
D941 Density and Relative Density (Specific Gravity) of Liquids
by Lipkin Bicapillary Pycnometer
K0D941
Pycnometer, side-arm type, 4.5 ±0.5mL,
Weight less than 30g
D1015 Freezing Points of High Purity Hydrocarbons
KD1015-FT
Freezing Point Tube, Glass, with Hi-Vac Stopcock
D1016 Purity of Hydrocarbons from Freezing Points
KD1015-AS
Apparatus for Obtaining Sample,
consisting of Dewar Flask, 50mL Condensing Tube,
3-way Stopcock, and Connecting Tubes 10mm OD
with S/J 18/7 Ball and Socket Joints
KD1015-NG
Distilling Apparatus for Gaseous Substances,
consisting of two Dewar Flasks, Distilling Tube,
and Receiver
KD1015-NL
Distilling Apparatus for Normally Liquid Substances,
consisting of Dewar Flask, Receiver, and 200mL Flask with Cap
D1018 Hydrogen in Petroleum Fractions
KD1018-A
Absorber Only, Turner Type
KD1018-B
Lamp Burner, S/T 14/20 Joints, Concentric Tubes
KD1018-CH
Hydrogen Determination Chimney
Erlenmeyer Flask, 14/10 S/T Outer Joint, 25mL
Standard Burner, 14/10 S/T Inner Joints
Chimney for Lamp Hydrogen Apparatus
Absorption Bulbs
Drierite U-Tube
D1266 Sulfur in Petroleum Products (Lamp)
KD1266-A
Absorber, S/T 24/40 Joints, Parallel Chambers, AU shape
KD1266-C
Chimney, S/T 14/10 and S/T 24/40 Joints
KD1266-ST
Spray Trap, S/T 24/40 Joint, 65mm OD
KD1266-SF
Standard Flask, 25mL, S/T 14/10 Joint, with Hooks
KD1266-FA
Flask for Aromatic Samples with Side Arm
KD1266-SB
Standard Burner, S/T 14/10 Joints
KD1266-BA
Burner for Aromatic Samples
D1347 Standard Method of Testing Methylcellulose
KD914
Apparatus for Testing Ethylcellulose
D1394 Jones-Blair Reductor
KD1394
Column, Jones-Blair Reductor,
19mm ID x 450mm Long, 4mm stpk
193
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 194
Glass Apparatus for ASTM Test Methods
D1480 Density and Relative Density of Viscous Materials
by Bingham Pycnometer
KD1480
Pycnometer, Bingham Type, Stoppered, 2mm ID neck, 10mL
D1481 Density and Relative Density of Viscous Materials
by Lipkin Bicapillary Pycnometer
KD1481
Pycnometer, Side-Arm Type, Weight less than 35 grams, 10mL
D1505 Density Gradient Determination
KD1505-C
Density Gradient Column, Jacketed, 38mm ID x 44" long
KD1505-F
Density Float (specify exact density and color identification)
D2002 Isolation of Representative Saturates Fractions
from Low-Olefinic Petroleum Naphthas
KD2002-C-1 Alternate Analytical Absorption Column, w/top adapter
KD2002-C
Absorption Column, Analytical, Water Jacketed
KD2002-ER
Eluant Reservoir, 250mL, S/J 28/15 Joints with Stopper
KD2002-R
Receiver, 10mL with TFE Stopcock and S/T 14/35 Joint
D1541 Iodine Flasks
K00D29-125 Iodine Flask, 125mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-250 Iodine Flask, 250mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-300 Iodine Flask, 300mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-500 Iodine Flask, 500mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
K00D29-1000 Iodine Flask, 1000mL, S/T 24/40 Mercury Seal
w/Hollow Stopper
D2003 Isolation of Representative Saturates
Fraction from High-Olefinic Petroleum Naphthas
KD2003-AC
Absorption Column, Water Jacketed, S/J 28/15
and S/T 14/35 Joints
KD2003-R
Receiver, Graduated, 10mL, S/T 14/35 Joint, TFE Stopcock
D1607 Sampling Nitrogen Dioxide in Small Concentrations
KD1607
Gas Bubbler Apparatus, S/T 29/42, S/J 18/7, Coarse Pencil Frit
D1638 Specific Gravity of Pigments, Drying Oils, Varnishes, Resins, etc.
K0C135-10
Pycnometer, 10mL, with Thermometer and Cap
K0C135-25
Pycnometer, 25mL, with Thermometer and Cap
K0C135-50
Pycnometer, 50mL, with Thermometer and Cap
K0C135-100 Pycnometer, 100mL, with Thermometer and Cap
D1839 Amyl Nitrate in Diesel Fuels
KD1839-F
Flask, Distilling, 300mL, S/T 24/40 Joint
KD1839-DC
Distillate Collector, S/T 24/40 Joints
KD1839-C
Condenser, Allihn, 300mm, S/T 24/40 Joint
KD1839-VF
Volumetric Flask, 100mL, Stoppered
KD1839-FF
Funnel for Volumetric Flask
D1949 Separation of Tetraethyllead and Tetramethyllead in Gasoline
KD1949-F
Flask, 200mL, S/T 24/40 Joint
KD1949-DC
Distilling Column, 12mm IDx300, Vacuum Jacketed (w/o Beads)
KD1949-C
Condenser, Liebig type, S/T 10/30 Top Joint, 100mm
D1963 Specific Gravity of Pigments, Drying Oils, Varnishes, Resins, etc.
K0C135-10
Pycnometer, 10mL, with Thermometer and Cap
K0C135-25
Pycnometer, 25mL, with Thermometer and Cap
K0C135-50
Pycnometer, 50mL, with Thermometer and Cap
K0C135-100 Pycnometer, 100mL, with Thermometer and Cap
D1966 Determination of Water and Sediment By Centrifuge Method
KD1966
Centrifuge Tube, Pear-Shape, 100mL
with Lower Stem Graduated to 1.5mL in 0.1mL divisions
D2001 Depentanization of Gasoline and Naphthas
KD2001-A
Distillation Column, Jacketed, 13mm ID
KD2001-B
Reflux Condenser Head for Distillation Column
KD2001-C
Trap for Light End Depentanization
KD2001-D
Receiver, Graduated, 12.5mL, S/T 19/38 Male Joint
KD2001-E
Dewar Flask, for Immersion of Receiver
KD2001-F
Flask, Distilling, 100mL, R.B., S/T 24/40 Joint
D2007 Characteristic Groups in Rubber Extender and Processing Oils
and other Petroleum-Derived Oils by the Clay-Gel
Absorption Chromatographic Method
KD2007-C
Clay-Gel Percolating Column (2 required), S/T 24/40,
Fritted Disc
KD2007-F
Distillation Flask, 3-neck, 500mL, S/T 24/40 Joint,
for Extraction
KD2007-H
Distillation Head with Vigreaux Column, S/T 24/40,
TFE Stopcock
KD2007-CT
Connecting Tube from Flask to Column, S/T 24/40
(If ordered with Flask, Head, and Column, Tube can be
supplied custom fitted. Otherwise user must heat glass tube
to soften and align and conform to fit properly, or install a
flexible connection device such as teflon bellows or slip-fit
teflon tubing sleeve).
KD2007-RC
Reflux Condenser, S/T 24/40, Friedrichs
KD2007-B
Beaker, Anticreep, 150mL
KD2007-APC Azobenzene Percolation Column, 12x600mm, 125mL Reservoir
KD2007-MV Teflon Metering Stopcock for Azobenzene Percolation Column
D2036 Determination of Cyanides in Water
KD2036
Complete Distillation Apparatus, consisting of 1000mL
2-neck Flask, Cold Finger Condenser, Absorber Trap, Inlet Tube
D2111 Determination of Specific Gravity of Liquid Chemicals,
Halogenated Organic Solvents Ethylene Glycols and Propylene Glycols
K0D891-25
Specific Gravity Bottle for Volatile Liquids, 25mL, Jacketed
K0D891-50
Specific Gravity Bottle for Volatile Liquids, 50mL, Jacketed
D2162 Basic Calibration of Master Viscometers
And Viscosity Oil Standards
KD2162-C1
Cannon Master Viscometer,
Approximately 0.001-0.003cSt/s
KD2162-C3
Cannon Master Viscometer,
Approximately 0.003-0.009cSt/s
KD2162-U1
Ubbelohde Master Viscometer,
Approximately 0.001-0.003cSt/s
KD2162-U3
Ubbelohde Master Viscometer,
Approximately 0.003-0.009cSt/s
194
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 195
Glass Apparatus for ASTM Test Methods
D2780 Solubility of Fixed Gases in Liquids
KD2780-PS
Ambient Pressure Saturator, Glass, 1000mL, S/T 27 Joint,
PTFE Stopcock w/O-Rings, Upper Head for Gas Inlet,
Outlet and Dispersion Element, and Heating Mantel
and Thermocouple wire x 6 ft long
KD2780-ES
Gas Extraction System consisting of KD2780-ES1
through KD2780-ES7
KD2780-ES1 Reflux Condenser, Liebig, S/T 24/40, 300mm
KD2780-ES2 Gas Extraction Chamber, 60 x 280mm, S/J 12/2 Joints
KD2780-ES3 Boiler Flask, 500mL, Round Bottom, S/J 35/25 Socket Joint,
with Adapter, 35/25 x 12/2 S/J Joint
KD2780-ES4 Gas Buret, Water Jacketed, 100mL, with 3-Way,
TEE Bore Stopcock and S/J 12/2 Joint
KD2780-ES5 Leveling Bulb, 500mL
KD2780-ES6 Connecting Manifold with 3 - TFE 120 Degree Stopcocks
KD2780-ES7 Manometer, Open End, 1-Meter, S/J 12/2 Connection
D2184 Determination of Isotopic Concentration
of Heavy Water.
KD2184-P
Pycnometer, 25mL, S/T 7/15 Stopper
KD2184-MS2 Matched Set of two Pycnometers
D2352 Determination of Carbon Dioxide and Sulfur Dioxide in Carbonates
K0D215
Alkalimeter, Knorr, 250mL Flask, S/T 24/40 and S/T 16
D2363 Testing of Hydroxpropyl Methylcellulose
KD2363
Complete apparatus for Steam Distillation including
Steam Boiler Tube with Inlet Adapter,
25mL Boiling Flask with Side Neck, Vigreaux Column,
110mm long Liebig Type Condenser,
and Vertical Adapter for delivery (S/T 14/20 Joints)
(boiler has S/T 24/40 joints)
D2385 Hydrogen Sulfide and Mercaptan Sulfur In Natural Gas
(Cadmium Sulfate Iodometric Titration Method)
KD2385-GWB Gas Washing Bottle, 70x280mm, Coarse Fritted Disc,
S/T 24/40
KD2385-ST
Spray Trap, S/T 24/40 Joint, 65mm OD Bulb
D2879 Vapor Pressure-Temperature Relationship and Initial
Decomposition Temperature of Liquids by Isoteniscope
KD2879
Isoteniscope Pressure Manometer, 8mm Od x 500mm w/bulb
D2886 Vacuum Trap
KD2886
Vacuum Trap, 22x125mm, Inlet & Outlet Arms 10mm OD
D2420 Hydrogen Sulfide in LP Gases by Lead Acetate Method
KD2420
Apparatus including Cylinder, Stoppers, Watch Glass
and Glass Rod
D2892 Distillation of Crude Petroleum (15- Theoretical Plate Column)
Quotations submitted on request. Specify Type, Scale,
and Sizes of Components Required.
D2533 Vapor-Liquid Ratio of Spark-Ignition Engine Fuels
KD2533
Buret, Vapor-Liquid Ratio, Graduated 0 - 35mL
D2910 Extraction Apparatus
KD2910
Complete Extraction Apparatus consisting of 3000 mL
Solvent Flask, Extractor Body with Extraction Chamber,
Siphon Tube, Removable Filter and Top Lid,
and Allihn Condenser 250mm. Joints are S/T 45/50
D2549 Separation of Representative Aromatics and Nonaromatics
Fractions of High-Boiling Oils by Elution Chromatography
KD2549-C2
Chromatographic Column, 10x760mm, 100mL bulb,
for 2 gram
KD2549-C10 Chromatographic Column, 15x1150mm, 200mL bulb,
for 10 gram
D2912 Oxidant Content of Atmosphere
KD2912
Impinger, Midget, S/T 24/40, 25mm Body, 5mm Inlet,
1mm Nozzle, Body Graduated 0-25mL in 5mL Divisions
D2569 Distillation of Pitch
KD2569-F
Flask, Distillation, 300mLx131mm tall
w/side arm 10x220mm
KD2569-F
Condenser, Air, 13x360mm
D2913 Mercaptan Content of Atmosphere
KD2913
Impinger, Midget, S/T 24/40, 25mm Body Graduated to 25mL
in 5mL Divisions, 5mm ID inlet, Coarse Fritted Pencil at Tip
D2619 Hydrolytic Stability of Hydraulic Fluids (Beverage Bottle Method)
K00D96-8
Centrifuge Tube, Conical, A8-Inch (203mm), 100mL
D2914 Oxidant Content of Atmosphere
KD2912
Impinger, Midget, S/T 24/40, 25mm Body, 5mm Inlet,
1mm Nozzle, Body Graduated 0-25mL in 5mL Divisions
D2717 Thermal Conductivity of Liquids
KD2717
Thermal Conductivity Cell, Platinum Resistance Thermometer
D2748 Determination of Pyridine Bases in Acids
KD2748
Distillation Apparatus Consisting of 1000mL Boiling Flask,
Bulb Trap Adapter, Connection Adapter, 600mm Liebig Type
Condenser, and Lower Drip Adapter, S/T 24/40 Joints
D2972 Determination of Arsenic in Water
KD2972
Arsenic Determination Apparatus consisting of
125mL Erlenmeyer Flask, Scrubber Tube, and Absorber Tube,
S/T 24/40 and S/J 12/2
D3120 Trace Quantities of Sulfur in Light Liquid Petroleum Hydrocarbons
by Oxidative Microcoulometry
KD3120
Pyrolysis Tube, Quartz, S/J 18/9 Ball exit, 6mm Inlets, Septum
D3234 Abrasion Resistance of Petroleum Wax Coatings
KD3234-T
Glass Tube, 1" ID x 12" Long,
with Support Device for #12 Sieve
KD3234-S
Screen Sieve, Size #12, cut 1" Diameter
KD3234-F
Separatory Funnel, 500mL, 4mm TFE Stopcock,
Stem Cut Short
195
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 196
Glass Apparatus for ASTM Test Methods
D3242 Acidity in Aviation Turbine Fuel
KD3242
Titration Flask, 500mL, Erlenmeyer Shape, with Inlet Tube
D3246 Sulfur in Petroleum Gas By Oxidative Microcoulometry
KD3120
Pyrolysis Tube, Quartz, S/J 18/9 Ball exit, 6mm Inlets, Septum
D3431 Trace Nitrogen in Liquid Petroleum Hydrocarbons
(Microcoulometric Method)
KD3120
Pyrolysis Tube, Quartz, S/J 18/9 Ball exit, 6mm Inlets, Septum
D3505 Density of Liquid Hydrocarbon Materials
K0D941
Pycnometer, Side Arm Type, 4.5 ±0.5mL, Weight less than 30g
D3608 Sampling Low Concentrations of Nitrogen Dioxide
KD1607
Gas Bubbler Apparatus, S/T 29/42, S/J 18/7, Coarse Pencil Fit
D3712 Analysis of Oil-Soluble Petroleum Sulfonates
by Liquid Chromatography
KD3712-C
Chromatographic Column, 22 x 300mm
w/250mL Reservoir, 28/15
KD3712-P
Pycnometer for Determining Specific Gravity, 50mL ±1.0mL
D3825 Dynamic Surface Tension by the Fast-Bubble Technique
KD3825
Glass Bubbler Unit, Jacketed, without Pressure Transducer
D3831 Manganese in Gasoline by Atomic Absorption Spectrometry
KD3831
Automatic Pipette, 9.0mL, with Auto-zero and TFE Stopcock
D3867 Test for Nitrite-Nitrate in Water
KD3867
Cadmium Reduction Column, 5x200mm, 85mL Reservoir
D3904 Oil from Oil Shale (Resource Evaluation
by the USBM Fischer Assay Procedure)
KD3904-R
Receiver, 100mL Centrifuge Tube, Pear Shape
KD3904-A
Adapter, S/T 24/40, to Receive Product from Retort
KD3904-C
Condenser, Allihn, 300mm, S/T 24/40
D3907 Testing Fluid Cracking Catalysts by Microactivity Test
KD3907-R
Glass Reactor body, 18mmx376mm, S/T 28/15
and 12/5 O-ring Joints
KD3907-PR
Product Receiver, Liquid, S/T 12/5 O-ring Joints
D3908 Hydrogen Chemisorption on Supported Platinum on
Alumina Catalysts by Volumetric Vacuum Method.
KD3908
Sample Cell, S/T 10/30 Joints, 2mm Vacuum Stopcocks
D4006 Water in Crude Oil by Distillation
KD4006-A
Distillation Trap, 5mL in 0.05
KD4006-B
Drying tube for Distillation Apparatus
KD4006-C
Condenser, 400mm, Liebig, S/T 24/40
KD4006-F
Flask, 1000mL, S/T 24/40, Round Bottom
D4180 Vibratory Packing Density of Formed Catalyst Carriers
KD4180
Feed Funnel, 100mm x 20mm ID
D4484 Inorganic Particles in Marine Residual Fuel Oils
by Selective Centrifugal Separation
KD2709
Centrifuge Tube, Conical, 100mL,
Tip Graduated to .05mL in .01 Divisions
D4486 Kinematic Viscosity of Volatile and Reactive Liquids
KD4486
Viscometer for Vulnerable Liquids
(specify approximate constant)
D4512 Vibrated Apparent Packing Density of Fine Catalyst Particles
and Powder
KD4180
Feed Funnel, 100mm x 20mm ID
D4629 Organically Bound Trace Nitrogen in Liquid Petroleum Hydrocarbons
by Oxidative Combustion and Chemilluminescence Detection
KD4629
Pyrolysis Tube, Quartz, S/J 18/9 Ball outlet,
6mm Inlets, Septum
D4814 Automotive Spark-Ignition Engine Fuel
KD2533
Buret, Vapor-Liquid Ratio, Graduated, 0-35mL
D4871 Guide for Universal Oxidation/Thermal
Stability Test Apparatus
KD4871-TC
Test Cell, 38 x 300mm, S/T 34/45 Joint
KD4871-C
Condenser, Allihn, 330mm, S/T 34/45 Joint, Top 9mm ID
KD4871-G11 Gas Inlet Tube, 8x850mm with Capillary Tip (no Support Ring)
KD4871-G11A Alternate Gas Inlet Tube, 8x850mm with Capillary Tip
but w/Support Ring
KD4871-G12 Gas Inlet Tube, 8x455mm, Capillary Tip, Top Bent 90 Degrees
KD4871-BH
Basic Head, S/T 34/45 Joint, Septum Port, Screw Cap Joint
KD4871-1H
Intermediate Head, S/T 34/45, 170mm long, Septum Port
KD4871-SH
Sampling Head, S/T 34/45 x 175mm long, Septum Port
KD4871-SR
Support Ring, 9.5mm IDx12.7mm ODx7mm long with 4 Hooks
KD4871-SP
Spacer Ring, 9.5 mm ID x 12.7mm OD x 7mm Long
D3945 Shear Stability of Polymer-Containing Fluids
Using a Diesel Injector Nozzle
KD3945-CV
Cooling Vessel, Jacketed, 25mm IDx180mm long,
TFE Stopcock
KD3945-FR
Fluid Reservoir, 250mL, w/Distributor Plate
and 3-way Stopcock
196
0-183-197_11_Thermom_Layout 1 10/24/12 11:40 AM Page 197
Standardized Metal Test Specimens
For those specimens not previously mentioned in this catalog, following is a
list, by test method, of available standardized metal test specimens. Please
contact Koehler Customer Service for additional information.
Test Method No.
Federal Test Methods
791-2503
791-2504
791-3007
791-3462
791-3805
791-3810
791-3814
791-4001
791-4011
791-5304
791-5305
791-5306
791-5307
791-5308
791-5309
791-5310
791-5311
791-5312
791-5314
791-5315
791-5321
791-5322
791-5323
791-5324
791-5325
791-5329
791-5331
791-6503
791-7001
ASTM Methods
D115
D609
D849
D897
D1261
D1275
D1384
D1402
D2266
D2511
D2570
D2596
D2619
D2688
D2783
D2847
D3810
D4635
D4871
E8
F483
F484
F519
Military Standards (MIL)
MIL-A-7866
MIL-A-8243
MIL-B-81705
MIL-C-6529
MIL-C-11796
MIL-C-15074
MIL-C-19853A
MIL-C-16173
MIL-C-22230
MIL-C-23411
MIL-C-25769H
MIL-C-46113
MIL-C-81309A
MIL-L-6085
MIL-L-7808
MIL-L-7870
MIL-L-8937
MIL-L-23398
MIL-L-23699
MIL-L-23699B
MIL-L-25017C
MIL-L-46000
MIL-L-46010
MIL-L-B1329
MIL-R-81294
MIL-R-25143A
MIL-S-8660
197
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:41 AM Page 198
Spare Parts
Spare parts are generally available from stock for immediate shipment from
our manufacturing facility in Bohemia, New York. The parts listings in this
section are for customers who may wish to maintain a stock of spares at their
facility for several years of operation. This may be of particular interest to
overseas customers. Suggested quantities are in parentheses ( ).
Please note: The parts listed in this section are for current equipment models
at the time of printing. When ordering spare parts for new equipment from this
catalog, substitutions may be made by Koehler to reflect engineering changes.
Koehler will provide written notification of any changes before processing your
order. When ordering spare parts for existing equipment, please specify the
model number and serial number of your equipment. This will insure that the
correct parts are supplied.
K10020 Powertrol Heater, 115V...........................................................Page 43
225-115-002
Heater 1000W (1)
010-115-005
Wattstat, 115V
K10029 Powertrol Heater, 220-240V ...................................................Page 43
225-230-002
Heater, 1000W (1)
010-230-005
Wattstat, 230V
K10090 U-Tube Aniline Apparatus, 115V............................................Page 43
K10050
Belt (1)
K10060
Pyrex U-Tube (1)
279-063-002
Bulb (1)
288-115-001
Motor (1)
289-002-001
Bearings (4)
K10091 U-Tube Aniline Apparatus, 220-240V ....................................Page 43
K10050
Belt (1)
K10060
Pyrex U-Tube (1)
279-063-002
Bulb (1)
K10091-09000
Motor, Modification (1)
289-002-001
Bearings (4)
K10190 Thin Film Aniline Apparatus, 115V........................................Page 43
K10050
Belt (1)
K10120
Pyrex Pump Body (1)
K10130
Thin Film Tube (1)
279-063-002
Bulb (1)
288-115-001
Motor (1)
289-002-001
Bearings (2)
K10191 Thin Film Aniline Apparatus, 220-240V................................Page 43
K10050
Belt (1)
K10120
Pyrex Pump Body (1)
K10130
Thin Film Tube (1)
279-063-002
Bulb (1)
289-002-001
Bearings (2)
K10091-09000
Motor, Modification (1)
K10200 Automatic Aniline Apparatus, 115V.......................................Page 42
K10220
Heating & Cooling Tube (1)
K102-5S
Flexible Drive Shaft (1)
280-115-001
Powerstat (1)
288-115-001
Motor (1)
279-115-001
Indicator Light Bulb (2)
278-010-001
Fuse, 10A (1)
K102-20
Heater Coil (1)
289-001-001
Bearings (2)
K10290 Automatic Aniline Apparatus, 220-240V...............................Page 42
K10220
Heating & Cooling Tube (1)
K102-5S
Flexible Drive Shaft (1)
280-115-001
Powerstat (1)
288-115-001
Motor (1)
279-115-001
Indicator Light Bulb (2)
278-010-001
Fuse, 10A (1)
K102-20
Heater Coil (1)
289-001-001
Bearings (2)
240-230-001
Transformer (1)
K10400 Oxidation Stability Bath, 2-Unit, 115V ..........................Pages 81, 82
K10400-11001
Heater, 2000W
379-001-001
Liquid Level Switch
K10401 Oxidation Stability Bath, 2 Unit, 115V ..........................Pages 81, 82
220-120-007
Cartridge Heater, 250W (6)
265-122-002
RTD Temperature Probe, 3 in., 2 Wire
265-122-003
RTD Temperature Probe, 3 in., 3 Wire
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K10402 Oxidation Stability Bath, 2-Unit, 220-240V ..................Pages 81, 82
K10402-11001
Heater, 2000W
379-001-001
Liquid Level Switch
K10403 Oxidation Stability Bath, 4-Unit, 115V ..........................Pages 81, 82
220-120-007
Cartridge Heater, 250W (10)
265-122-002
RTD Temperature Probe, 3 in., 2 Wire
265-122-003
RTD Temperature Probe, 3 in., 3 Wire
278-030-002
Fuse, 30A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K10404 Oxidation Stability Bath, 6 Unit, 220-240V...................Pages 81, 82
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K10491 Oxidation Stability Bath, 2-Unit, 220-240V ..................Pages 81, 82
220-240-006
Cartridge Heater, 250W (6)
265-122-002
RTD Temperature Probe, 3 in., 2 Wire
265-122-003
RTD Temperature Probe, 3 in., 3 Wire
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K10493 Oxidation Stability Bath, 4-Unit, 220-240V ..................Pages 81, 82
220-240-006
Cartridge Heater, 250W (10)
265-122-002
RTD Temperature Probe, 3 in., 2 Wire
265-122-003
RTD Temperature Probe, 3 in., 3 Wire
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32 V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
198
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:41 AM Page 199
Spare Parts (Continued)
K10500 Oxidation Pressure Vessel......................................................Page 80
K10510
Composition Gaskets
K105-0-12
Relief Tube
260-102-005
Rupture Disc, Alum with Liner
260-104-015
Burst Disc Holder
461-001-001
Silicone Vacuum Grease
K10901 Oxidation Bath, 115V.....................................................Page 152-153
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-030-002
Fuse, 30A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
275-103-024
Temperature Controller, 100-240V, 1 out
K10991 Oxidation Bath, 220-240V.............................................Page 152-153
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
275-103-024
Temperature Controller, 100-240V, 1 out
K11201 Reid Vapor Pressure Bomb for LPG ......................................Page 92
AS568-210
O-ring (1)
AS568-113
O-ring (1)
K11415/K11416 Reid Vapor Pressure Bath,
21-Unit, 220-240V, 50Hz and 60Hz ..................................................Page 93
235-240-005
Heater, 6000W (1)
265-400-002
RTD Temperature Probe (1)
K11450 Reid Vapor Pressure Bath, 4-Unit, 115V ..............................Page 93
K11450-0-1
Heater, 2000W, 115V
K70519
RTD Temperature Probe, 12 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
K23700-03013A Motor, 115V 60Hz
275-103-020
Temperature Controller, 100-240V, 2 out
K11459 Vapor Pressure Bath, 4-Unit, 220-240V................................Page 93
K11459-0-1
Heater, 2000W, 230V
K70519
RTD Temperature Probe, 12 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
K23700-03014A Motor, 230V 50/60Hz
275-103-020
Temperature Controller, 100-240V, 2 out
K12100 Oxidation Stability Bath, 115V .............................................Page 123
K121-0-17
Heater, 750W, 115V (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K23700-03013A Motor, 115V, 60Hz (1)
275-103-024
Temperature Controller, 100-240V, 1 out
K12190 Oxidation Stability Bath, 220-240V .....................................Page 123
K121A-0-17
Heater, 750W, 230V (1)
288-230-002
Motor, 230V, 50/60Hz (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
275-103-024
Temperature Controller, 100-240V, 1 out
K12200 Oxidation Stability Bath, 8-Unit, 115V ................................Page 120
K122-2-15B
Heater, 750W, Inner, 115V (1)
K122-2-15C
Heater, 750W, Outer, 115V (1)
K23700-03013A Motor, 115V 60Hz (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
275-103-024
Temperature Controller, 100-240V, 1 out
K12201 Solid Block Oxidation Bath, 220-240V ................................Page 121
091-240-003
Relay, 120/240V, 25A
265-400-004
RTD Probe, 10 in.
220-240-009
Heater, 750W, 220V (6)
K12212 Oxidation Stability Bath, 12-Unit, 115V ..............................Page 120
K122-12-2-22A Heater, 1500W, back, 115V (1)
K122-12-2-22B Heater, 1500W, middle, 115V (1)
K122-12-2-22C Heater, 750W, front, 115V (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
K23700-03013A Motor, 115V 60Hz (1)
K23300-03009
Stirrer Shaft
091-032-004
Relay, Solid State, 32 V DC
278-040-001
Fuse, 40A, Time Delay CLSG
275-103-027
Temperature Controller, 100-240V
K12219 Oxidation Stability Bath, 12-Unit, 220-240V ......................Page 120
K122-12A-2-22A Heater, 1500W, back, 220V (1)
K122-12A-2-22B Heater, 1500W, middle, 220V (1)
K122-12A-2-22C Heater, 750W, front, 220V (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-030-002
Fuse, 30A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K23700-03014A Motor, 230V 50/60Hz (1)
275-103-024
Temperature Controller, 100-240V, 1 out
K12290 Oxidation Stability Bath, 8-Unit, 220-240V.........................Page 120
K122A-2-15B
Heater, 750W, Inner, 230V (1)
K122A-2-15C
Heater, 750W, Outer, 230V (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K23700-03014A Motor, 230V 50/60Hz (1)
275-103-024
Temperature Controller, 100-240V, 1 out
199
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:41 AM Page 200
Spare Parts (Continued)
K12300 Series Oxidation Stability Bath, 220-240V, 50 and 60Hz ..Page 121
Model Numbers K12330, K12339, K12300, K12395
235-240-005
Heater, 6000W, 240V
265-400-002
RTD Temperature Probe, 12 in.
K13009 Saybolt Chromometer .............................................................Page 44
K13018
Gasket (pkg. of 12)
K13020
Color Standard (Full) (2)
K13029
Color Standard (Half) (1)
K13032
Glass Set, Turret & Draincock Assembly
K13061
Glassware Set with Connections
K13090
Frosted Mirror without Base (1)
K13012
Graduated Tube Gasket
K16000 Pensky-Martens Flash Tester, Gas.........................................Page 34
K160-9
Flexible Stirrer Shaft (1)
K16220-0-6
Drive Belt for Stirrer Motor
K16200 Pensky-Martens Flash Tester, 115V ......................................Page 34
225-115-002
Brick Heater, 1000W (1)
K160-9
Flexible Stirrer Shaft (1)
K16220-0-6
Drive Belt for Stirrer Motor
K16270 Pensky-Martens Flash Tester, 220-240V...............................Page 34
225-230-002
Brick Heater, 1000W (1)
K160-9
Flexible Stirrer Shaft (1)
K16220-0-6
Drive Belt for Stirrer Motor
K13100 Saybolt Wax Chromometer, 115V..........................................Page 44
K13018
Gasket (pkg. of 12)
K13020
Color Standard (Full) (1)
K13029
Color Standard (Half) (1)
K13033
Glass Set, Turret and Graduated Tube
K13090
Frosted Mirror without Base (1)
K131-0-26
Cartridge Heater, 115V (1)
K131-0-28
Strip Heater, 200W, 115V (1)
AS568-211
O-ring (2)
K17100 Wax Coating Device, 115V...................................................Page 177
190-120-009
Ring Heater, 200W (1)
K171-0-12
Doctor Rod Assembly
280-115-004
Variable Transformer
K13190 Saybolt Wax Chromometer, 220-240V ..................................Page 44
K13018
Gasket (pkg. of 12)
K13020
Color Standard (Full) (1)
K13029
Color Standard (Half) (1)
K13033
Glass Set, Turret and Graduated Tube
K13090
Frosted Mirror without Base (1)
K131A-0-26
Cartridge Heater, 50W, 230V (1)
K131A-0-28
Strip Heater, 200W, 230V (1)
AS568-211
O-ring (2)
K17200 Type A Blocking Plate, 115V ................................................Page 177
236-115-001
Strip Heater, 250W (1)
K17190 Wax Coating Device, 220-240V ...........................................Page 177
190-120-009
Ring Heater, 200W (1)
K171-0-12
Doctor Rod Assembly
240-230-001
Stepdown Transformer (1)
K17290 Type A Blocking Plate, 220-240V.........................................Page 177
236-230-001
Strip Heater, 250W (1)
K17300 Type B Blocking Plate, 115V ................................................Page 177
K173-0-11A
Heater, 100W (1)
K173-0-11C
Heater, 300W (1)
288-115-001
Motor (1)
K13900 Cleveland Flash Tester, 115V.................................................Page 36
K138-1-17
Insulation Plate (1)
225-115-002
Brick Heater, 1000W, 115V (1)
AS568-008
O-ring (1)
010-115-005
Wattstat, 115V (1)
K17390 Type B Blocking Plate, 220-240V.........................................Page 177
K173-0-11B
Heater, 100W (1)
K173-0-11D
Heater, 300W (1)
288-230-002
Motor (1)
K13990 Cleveland Flash Tester, 220-240V .........................................Page 36
K138-1-17
Insulation Plate (1)
225-230-002
Brick Heater, 1000W, 230V (1)
AS568-008
O-ring (1)
010-230-004
Wattstat, 230V (1)
K17500 Wax Melting Point Apparatus...............................................Page 178
K175-0-5
Cork, Sample Thermometer (1)
K175-0-6
Cork, Bath Thermometer (1)
285-000-006
Cork without hole (1)
K175-0-8
Sample Tube (1)
K14600 Tag Electric Closed Tester, 115V............................................Page 35
190-120-001
Ring Heater, 200W (1)
010-115-005
Wattstat, 115V (1)
K17600 Oil Solvent Extractables Content Apparatus, 115V ............Page 179
K176-1-0-26
Glass Manifold (1)
279-115-006
Lamp, 100W, 115V (1)
332-003-004
15mL Weighing Bottle (4)
K14670 Tag Electric Closed Tester, 220-240V ....................................Page 35
190-240-009
Ring Heater, 150W (1)
010-230-004
Wattstat, 230V (1)
K15600 Tag Electric Open Cup Flash Tester, 115V ............................Page 37
190-120-001
Ring Heater, 200W (1)
K138-0-11
Valve Stem (2)
K156-0-1A
Flame Test Burner and Pilot Assembly (1)
K15670 Tag Electric Open Cup Flash Tester, 220-240V.....................Page 37
190-240-009
Ring Heater, 150W (1)
K138-0-11
Valve Stem (2)
K156-0-1A
Flame Test Burner and Pilot Assembly (1)
K17690 Oil Solvent of Extractables Content Apparatus, 220-240V.......Page 179
K176-1-0-26
Glass Manifold (1)
279-230-004
Lamp, 100W, 230V (1)
332-003-004
15mL Weighing Bottle (4)
K17970/K17979 Corrosion Preventive Properties Apparatus,
115V and 220-240V..........................................................................Page 154
K17910
Test Bearings (3)
K17930
Containers/Lids (3)
K179-0-6
Spring
K179-0-8
Lockscrew
288-115-036
Motor, 115/230V, 60Hz
200
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:41 AM Page 201
Spare Parts (Continued)
K17980/K17989 Corrosion Preventive Properties Apparatus,
115V and 220-240V..........................................................................Page 154
AS568-224
O-ring (3)
AS568-329
O-ring (3)
360-115-015
Motor Speed Control
289-004-002
Outboard Bearing Set (3)
288-115-053
Motor, 1/4 hp, 130 V DC and Resistor
K18000 Manual Grease Working Machine .........................................Page 28
22H-308-20C
Wing Screws (6)
K18100 Series Mechanical Grease Workers, Single-Unit,
115V and 220-240V....................................................................Pages 26, 28
Model Numbers K18100, K18110, K18119
289-001-002
Ball Bearing (1)
320-115-001
Counter
050-001-006
Start/Stop Switch
050-001-007
Proximity Switch
K180-1-0-11
Clamp Spring (2)
271-015-001
Thermal Circuit Breaker, 15A
K18190 Series Mechanical Grease Workers, Double-Unit,
115V and 220-240V............................................................................Page 28
Model Numbers K18190, K18191, K18192
289-001-002
Ball Bearing (2)
320-115-001
Counter
050-001-006
Start/Stop Switch
050-001-007
Proximity Switch
K180-1-0-11
Clamp Spring (4)
271-015-001
Thermal Circuit Breaker, 15A
K18200 Water Spray Apparatus, 115V, 60Hz ...................................Page 163
301-002-006
Timing Belt (1)
K182-0-10
Heater, 750W (1)
K18210
Stainless Steel Test Panel
275-250-003
Electronic Temperature Controller
356-001-005
Gear Pump
039-104-00B
Snubber, Brass
165-308-001
Leveling Foot (4)
288-115-015
Motor 115V, 60Hz, 1/3 hp
K18290/K18295 Water Spray Apparatus,
220-240V, 50Hz and 60Hz ...............................................................Page 163
301-002-006
Timing Belt (1)
K182A-0-10
Heater, 750W (1)
K18210
Stainless Steel Test Panel
275-250-003
Electronic Temperature Controller
356-001-005
Gear Pump
039-104-00B
Snubber, Brass
165-308-001
Leveling Foot (4)
288-115-012
Motor 115/230V, 60Hz, 1/3 hp
288-115-010
Motor, 220-240V, 50Hz
K18300/K18320 Roll Stability Tester,
Single/Double Unit, 115V........................................................Pages 27, 156
325-000-025
#25 Chain (30")
237-115-002
Heater, Finned, Strip, 600W, 115V (2)
265-600-001
RTD Temperature Probe, 4 in. (1)
289-001-012
Ball Bearing (7)
AS568A-117-V01 Viton O-Ring
AS568A-154-V01 Viton O-Ring
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-020
Temperature Controller, 100-240V, 2 out
K18305 Series Roll Stability Tester, Single/Double-Unit,
220-240V, 50Hz ................................................................................Page 156
Model Numbers K18305, K18306, K18325, K18326
325-000-025
#25 Chain (30")
237-240-004
Heater, Finned, Strip, 600W, 240V (2)
265-600-001
RTD Temperature Probe, 4 in. (1)
091-032-001
Relay, Solid State, 4-32VDC, 20A
275-103-020
Temperature Controller, 100-240V, 2 out
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
K18348-13000
Motor Fan
AS589A-117-V01 Viton O-Ring
AS568A-154-V01 Viton O-Ring
K18340 Roll Stability Tester, 4-Unit, 115V, 60Hz.............................Page 156
237-115-001
Heater, Finned, Strip, 1000W, 115V (2)
265-600-001
RTD Temperature Probe, 4 in. (1)
289-001-012
Ball Bearing (17)
289-001-022
Ball Bearing (17)
091-032-001
Relay, Solid State, 4-32VDC, 20A
288-115-035
Motor, Gear, 115V, 60Hz, 83rpm
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
AS589A-117-V01 Viton O-Ring
AS568A-154-V01 Viton O-Ring
275-103-020
Temperature Controller, 100-240V, 2 out
K18345/K18346 Roll Stability Tester, 4-Unit,
220-240V, 50Hz and 60Hz ...............................................................Page 156
275-103-020
Temperature Controller, 100-240V, 2 out
265-600-001
RTD Temperature Probe, 4 in. (1)
K18348-13000
Motor, Fan
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
AS589A-117-V01 Viton O-Ring
AS568A-154-V01 Viton O-Ring
288-230-009
Motor, Gear, 230V, 50Hz, 70rpm
K18500 High Temperature Wheel Bearing Tester, 115V, 60Hz ......Page 161
215-115-001
Heater, 1200W, 115V (1)
288-115-004
Fan Motor (1)
K185-0-42
Cabinet Thermocouple (1)
288-018-021
Spindle Thermocouple (1)
289-004-001
Inboard Bearing Set
289-004-002
Outboard Bearing Set
K185-1-66
Motor, modification
K18590/K18595 High Temperature Wheel Bearing Tester,
220-240V, 50Hz and 60Hz ...............................................................Page 161
215-230-001
Heater, 1200W, 230V (1)
288-115-004
Fan Motor (1)
278-010-001
Fuse, 10A (5)
278-015-001
Fuse, 15A (5)
278-020-003
Fuse, 20A (5)
K185-0-42
Cabinet Thermocouple (1)
288-018-021
Spindle Thermocouple (1)
289-004-001
Inboard Bearing Set
289-004-002
Outboard Bearing Set
201
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:41 AM Page 202
Spare Parts (Continued)
K18700 Leakage Tendencies of Automotive Wheel Bearing Greases,
115V, 60Hz ........................................................................................Page 160
275-103-020
Temperature Controller, 100-240V, 2 out
200-115-006
Coil Heater, 1000W (2)
301-004-002
Vee Belt (60Hz) (1)
288-115-027
Motor
265-122-002
RTD Temperature Probe, 3 in. (1)
K18790 Leakage Tendencies of Automotive Wheel Bearing Greases,
220-240V, 60Hz ................................................................................Page 160
200-230-006
Coil Heater, 1000W (2)
301-004-002
Vee Belt (60Hz) (1)
265-122-002
RTD Temperature Probe, 3 in. (1)
288-115-027
Motor
275-103-020
Temperature Controller, 100-240V, 2 out
K18795 Leakage Tendencies of Automotive Wheel Bearing Greases,
220-240V, 50Hz ................................................................................Page 160
200-230-006
Coil Heater, 1000W (2)
301-004-005
Vee Belt (50Hz) (1)
265-122-002
RTD Temperature Probe, 3 in. (1)
288-230-005
Motor, 50Hz
K18850 Series Low Temperature Torque Apparatus,
220-240V, 50Hz and 60Hz ...............................................................Page 159
Model Numbers K18850, K18851, K18852, K18853, K18854, K18855,
K18860, K18861, K18862, K18863, K18864, K18865
301-002-007
Timing Belt (2)
265-000-002
Spindle Thermocouple (2) For all D4693 models
289-007-001
Boston 5F x 7⁄8 Flanged Bearing (4)
360-108-001
Strain Gauge (2)
K18860-0-16
Small Bearing Set (2) For all D4693 models
K18860-0-24
Large Bearing Set (2) For all D4693 models
288-230-007
Motor, 230V, 50/60Hz, 1/15 hp, 1.4A (1)
K18910 Constant Temperature Air Cabinet, 115V............................Page 165
K23700-03013A Motor, 115V, 60Hz
K189-1-0-17
Heater, 115V, 50W
283-120-002
Solenoid Valve, 115V (2)
265-400-002
RTD Temperature Probe
275-103-023
Temperature Controller, 100-240V
278-001-002
Fuse, 1A, Slo-blo
K18919 Constant Temperature Air Cabinet, 220-240V....................Page 165
288-230-002
Motor, 230V
K189-1A-0-17
Heater, 230V, 100W
283-240-001
Solenoid Valve, 230V (2)
265-400-002
RTD Temperature Probe
275-103-023
Temperature Controller, 100-240V
278-001-002
Fuse, 1A, Slo-blo
K19200 Water Washout Tester, 115V, 60Hz .....................................Page 162
K192-4-4
Heater, 380 W, 115V (1)
301-004-008
Vee Belt, 22”
301-004-007
Vee Belt, 37”
289-001-009
Ball Bearing (2)
289-001-006
Test Bearing (3)
K192-4-3
Thermoregulator
K192-2-5
Flowmeter
288-115-027
Motor
AS568-214
O-ring (2)
356-001-005
Water Pump
K192-1-8
Bearing Housing Gasket
K19290 Water Washout Tester, 220-240V, 60Hz..............................Page 162
K192A-4-4
Heater, 380W, 220V (1)
301-004-008
Vee Belt, 22”
301-004-007
Vee Belt, 37”
289-001-009
Ball Bearing (2)
289-001-006
Test Bearing (3)
AS568-214
O-ring (2)
K192-1-8
Bearing Housing Gasket
K192-4-3
Thermoregulator
K192-2-5
Flowmeter
288-115-027
Motor
356-001-005
Water Pump
K19295 Water Washout Tester, 220-240V, 50Hz..............................Page 162
K192A-4-4
Heater, 380W, 220V (1)
301-004-003
Vee Belt, 37”, 50 Hz (1)
288-230-005
Motor, 110/220V, 50Hz
K19400 High Temperature Dropping Point Apparatus, 115V..........Page 151
220-120-001
Heater (cartridge), 750W, 120V (1)
279-115-002
Lamp (1)
278-001-002
Fuse, 1A
265-203-001
Temperature Probe, Type “K”, 3⁄16 dia x 4”
K194EB
Test Tube 13x100mm (10)
K194EC
Cup Support (10)
275-103-023
Temperature Controller, 100-240V
091-240-002
Solid State Relay, 25A, 90-240V
K19410 High Temperature Dropping Point Apparatus,
220-240V...........................................................................................Page 151
220-240-001
Heater (cartridge), 750W, 240V (1)
279-115-002
Lamp (1)
278-001-002
Fuse, 1A
265-203-001
Temperature Probe, Type “K” (1)
K194EB
Test Tube 13x100mm (10)
K194EC
Cup Support (10)
275-103-023
Temperature Controller
091-240-002
Solid State Relay, 25A, 90-240V
K19490 Dropping Point Apparatus, 115V .........................................Page 150
K19492
Test Tube with Indentations
K19493
Thermometer Cork
K194A-0-7
Bath Thermometer Cork
332-002-005
400mL Beaker
010-115-005
Wattstat, 115V
225-115-002
Heater Element, 1000W, 115V
288-115-001
Motor
K19491 Dropping Point Apparatus, 220-240V..................................Page 150
K19492
Test Tube with Indentation
K19493
Thermometer Cork
K194A-0-7
Bath Thermometer Cork
332-002-005
400mL Beaker
010-230-004
Wattstat, 230V
225-230-002
Heater Element, 1000W, 230V
K19491-0-12
Motor, 230V, 50/60Hz, 1/40 hp
K19500 Penetrometer ...........................................................................Page 24
332-005-008
5" diameter Watch Glass (1)
K195-11
Plunger Drop Cushion
K195-23
Plunger Release Spacer
K195-24
Plunger Release Lever (1)
K195-29
Teflon Inserts
202
0-198-209_12a_SpareParts_Layout 1 11/1/12 2:21 PM Page 203
Spare Parts (Continued)
K21404/K21494 Automatic Saybolt Viscosity Timing Sensor ...........Page 16
K21404-03009
Sensor Assembly
K21404-23000
Cabinet Power Supply
K21404-03013
Flask Holder Assembly
K21410 Saybolt Viscometer Bath, 115V .............................................Page 16
K21410-0-15
Heater, 1200W, 115V (2)
K23700-03013A Motor, 115V, 60Hz (1)
265-500-001
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K21420 Saybolt Viscometer Bath, 220-240V......................................Page 16
K21420-0-15
Heater, 1200W, 230V (2)
K23700-03014A Motor, 230V, 50/60Hz (1)
265-500-001
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K22600/K22610 Pressure Viscometer, 115V and 220-240V...........Page 157
K226-0-20
Cylinder Gasket (6)
K226-0-21
Capillary Gasket (8)
265-000-001
Thermocouple (3)
288-115-014
Motor, 115/230V 60Hz (1)
349-000-009
Coupling Spider (1)
K22615 Pressure Viscometer, 220-240V, 50Hz................................Page 157
K226-0-20
Cylinder Gasket (6)
K226-0-21
Capillary Gasket (8)
265-000-001
Thermocouple (3)
288-230-005
Motor, 115/230V, 50Hz (1)
349-000-009
Coupling Spider (1)
K22680 Series Grease Mobility Tester, 115V and 220-240V ..........Page 158
Model Numbers K22680, K22685, K22686
K226-0-20
Cylinder Gasket (2)
K226-0-21
Capillary Gasket (1)
K22690 Series Low Temperature Pressure Viscometer,
115V and 220-240V, 50Hz and 60Hz ..............................................Page 157
Model Numbers K22690, K22695, K22696
320-000-003
Counter
288-115-014
Motor, 115/230V, 60Hz
288-230-005
Motor, 115/230V, 50Hz
K226-0-22
Capillary Set, No. 1-8
265-000-001
Thermocouple (3)
AS568-231
O-ring
K22751 Digital Refrigerated Kinematic Viscosity Bath,
115V.......................................................................................................Page 7
091-032-001
Solid State Relay, 4-32VDC, 20A
288-115-058
Stirrer Motor, 115V, 60Hz
335-115-004
Condenser Fan Motor, 115V
220-120-009
Heater (Cartridge), 500W, 115V
279-115-009
Fluorescent Lamp, 50W, 120V
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
265-500-001
RTD Temperature Probe
271-030-005
Switch, Circuit Breaker, 30A
K22752/K22754 Digital Refrigerated Kinematic Viscosity Bath,
220-240V ...............................................................................................Page 7
091-032-001
Solid State Relay
288-230-020
Motor, 230V, 50/60Hz
335-230-001
Condenser Fan Motor, 230V
220-240-013
Heater, 500W, 230V (2)
265-500-001
RTD Temperature Probe
279-115-009
Fluorescent Lamp, 50W, 120V
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
271-030-005
Switch, Circuit Breaker, 30A
K22753 Digital Refrigerated Kinematic Viscosity Bath,
115V.......................................................................................................Page 7
091-032-001
Solid State Relay
288-115-058
Motor, 115V, 60Hz
335-115-004
Condenser Fan Motor, 115V
220-120-009
Heater, 500W, 115V (2)
265-500-001
RTD Temperature Probe
279-115-009
Fluorescent Lamp, 50W, 120V
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
271-025-001
Switch, Circuit Breaker, 25A
K23700/K23800 Series Kinematic Viscosity Baths,
115V, 60Hz.......................................................................................Pages 4-5
Model Numbers K23700, K23702, K23706, K23708, K23800, K23802
K23700-02003
RTD Temperature Probe
278-104-002
Fuse, 0.25A
279-115-009
Fluorescent Lamp, 50W, 120V
335-115-005
Fan, 115V, 50/60Hz, 53CFM
332-001-001
Borosilicate Glass Jar, 12"x12"
332-001-003
Borosilicate Glass Jar, 12"x18"
K23700-03006
Heater, 1250W, 115V, For Standard Temperature Models
K23800-03006
Heater, 1700W, 115V, For High Temperature Models
K23700-03013A Motor, 115V 60Hz
275-103-027
Temperature Controller, 100-240V
K23700/K23800 Series Kinematic Viscosity Baths,
220-240V, 50Hz/60Hz......................................................................Pages 4-5
Model Numbers K23790, K23792, K23796, K23798, K23890, K23892
K23700-02003
RTD Temperature Probe
278-104-002
Fuse, 0.25A, Slo-blo
278-101-002
Fuse, 1A
278-101-004
Fuse, 20A
279-115-009
Fluorescent Lamp, 50W, 120V
335-230-005
Fan, 230V, 50/60Hz, 53CFM
332-001-001
Borosilicate Glass Jar, 12"x12"
332-001-003
Borosilicate Glass Jar, 12"x18"
K23700-03015
Heater, 1250W, 230V, For Standard Temperature Models
K23800-03015
Heater, 1700W, 230V, For High Temperature Models
K23700-03014A Motor, 230V 50/60Hz
K23702-OS, K23792-OS, K23708-OS, K23798-OS
Kinematic Viscosity Bath ......................................................................Pages 5
360-030-001
Amplifier, 110-30 VDC, blue led
275-600-007
Touch Screen Interface, PLC
275-600-005
Controller, PLC, 100-240 VAC
K23702OS-03038 Holder, Reflector
K25310/K25320 Copper Strip Corrosion Test Bath,
4-Unit and 8-Unit, 115V ......................................................Pages 90, 91, 99
K253-1-0-8
Heater, 750W (K25310) (1)
K253-2-0-8
Heater, 750W (K25320) (1)
191
RTD Probe Assembly
275-250-003
Electronic Temperature Control
203
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:42 AM Page 204
Spare Parts (Continued)
K25319/K25329 Copper Strip Corrosion Test Bath,
4-Unit and 8-Unit, 220-240V...............................................Pages 90, 91, 99
K253-1A-0-8
Heater, 750W (K25319) (1)
K253-2A-0-8
Heater, 750W (K25329) (1)
191
RTD Probe Assembly
275-250-003
Electronic Temperature Control
K26490 Constant Temperature Hydrometer Bath, 220-240V ............Page 50
K26490-1-5
Heater, 1500W (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
091-032-001
Relay, Solid State, 4-32 V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K25330 Test Tube Bath, 115V......................................Pages 90, 91, 131, 155
K346-0-3
Heater, 750W, 115V (1)
K23700-03013A Motor, 115V 60Hz
K70519
RTD Temperature Probe, 12 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-020
Temperature Controller, 100-240V, 2 out
K26500 Thermometer Calibration Bath, 115V....................................Page 63
K26500-0-15
Heater, 750W (1)
265-500-001
RTD Temperature Probe (1)
288-115-001
Motor (1)
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-025
Temperature Controller, 100-240V
K25339 Test Tube Bath, 220-240V..............................Pages 90, 91, 131, 155
K346A-0-3
Heater, 750W, 230V (1)
K70519
RTD Temperature Probe, 12 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
K23700-03014A Motor, 230V 50/60Hz
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-020
Temperature Controller, 100-240V, 2 out
K26590 Thermometer Calibration Bath, 220-240V............................Page 63
K26500-0-15A
Heater, 750W (1)
265-500-001
RTD Temperature Probe (1)
288-230-010
Motor 230V 50/60Hz (1)
275-103-025
Temperature Controller, 100-240V
K27000 Smoke Point Lamp ..................................................................Page 95
K27040
Replacement Window (1)
K270-0-22
Scale (1)
K25900 Constant Temperature Water Bath, 115V 60Hz..................Page 103
K25900-0-15
Heater, 750W (1)
010-500-003
Temperature Probe, 500Ω (1)
K23700-03013A Motor, 115V 60Hz
010-115-002
Type “B” Controller
010-010-002
Potentiometer
356-115-001
Pump
K27100 Ramsbottom Carbon Residue Apparatus, 115V...................Page 59
230-115-001
Heater, 2400W (1)
265-203-001
Temperature Probe, Type “K”, 3⁄16 dia x 4”
278-030-002
Fuse, 30A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-002
Relay, Solid State, 4-32V DC, 30A
275-103-024
Temperature Controller, 100-240V, 1 out
K25990/K25995 Constant Temperature Water Bath,
220-240V, 50Hz and 60Hz ...............................................................Page 103
K25990-0-15
Heater, 1000W (1)
010-500-003
Temperature Probe 500Ω (1)
K23700-03014A Motor, 230V 50/60Hz
010-115-002
Type “B” Controller
010-010-002
Potentiometer
356-115-001
Pump
K27190 Ramsbottom Carbon Residue Apparatus, 220-240V ...........Page 59
230-230-002
Heater, 2400W (1)
265-203-001
Temperature Probe, Type “K”, 3⁄16 dia x 4”
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K26150 Pressure Hydrometer Cylinder.............................................Page 103
AS568-032
O-Ring, Buna 'N' (2)
K26015
Lucite Cylinder
260-104-001
Pressure Relief Valve, 1/4"
K26150-0-6
Neoprene Cushion (2)
K28300 Bending Apparatus ................................................................Page 173
K283-0-14
Test Panel (12)
K26200 Constant Temperature Hydrometer Bath, 115V....................Page 50
K262-0-10
Heater, 500W (1)
354-001-002
Rheostat (1)
K26290 Constant Temperature Hydrometer Bath, 220-240V ............Page 50
K262A-0-10
Heater, 500W (1)
354-001-002
Rheostat (1)
K26400 Constant Temperature Hydrometer Bath, 115V....................Page 50
K26400-1-5
Heater, 1500W (1)
K26400-1-5A
Heater, 1000W (1)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
091-032-002
Relay, Solid State, 4-32 V DC, 30A
275-103-024
Temperature Controller, 100-240V, 1 out
K28310 Cooling Apparatus .................................................................Page 173
K28310-0-1
Large Stopper
K28310-0-2
Small Stopper
K28310-0-3
Inner Flask
K297-0-1
Vacuum Flask
332-014-001
Funnel
K29300 High Temperature Evaporation Loss Apparatus .................Page 149
190-240-003
Ring Heater, 500W, 240V (2)
220-240-002
Cartridge Heater, 650W (2)
265-203-001
Temperature Probe, Type "K", 4 in., (2)
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
010-230-004
Wattstat (2)
K293-0-12
Thermocouple (2)
K293-0-20
Flowmeter (2)
204
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:42 AM Page 205
Spare Parts (Continued)
K29400 Evaporation Loss Bath, 115V ...............................................Page 148
K294-0-1
Heater, 1000W (1)
K23700-03013A Motor, 115V 60Hz
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K29490 Evaporation Loss Test Bath, 220-240V................................Page 148
K294A-0-1
Heater, 1000W (1)
K23700-03014A Motor, 230V 50/60Hz
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K29700 Freezing Point Apparatus........................................................Page 96
K297-0-1
Vacuum Flask (1)
K297-0-2
Sample Tube (Jacketed) (1)
K297-0-8
Cork Strip (1)
K297-0-5
#2 Neoprene Stopper
K29750/K29758/K29759 Freezing Point Apparatus (ASTM D1177),
115V and 220-240V............................................................................Page 68
K29750-1-1
200mL Tube (1)
332-003-012
2 quart Dewar Flask (1)
K29760/K29768/K29769 Wax Appearance Point Apparatus,
115V and 220-240V............................................................................Page 94
K297-0-1
Vacuum Flask (1)
K29760-0-2
Sample Tube (1)
K29900/K29990 Lead Corrosion Apparatus,
220-240V, 50Hz and 60Hz ...............................................................Page 130
K23700-03014A Bath Motor, 230V 50/60Hz (1)
K299-0-45A
Outer Heater, 500W (1)
K299-0-45B
Middle Heater, 500W (1)
K299-0-45C
Inner Heater, 2000W (1)
265-600-001
RTD Temperature Probe, 4 in.
K70519
RTD Temperature Probe, 12 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32 V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K30160/K30161 Rust Preventing Characteristics Oil Bath,
115V, 60Hz................................................................................Pages 98, 128
K301A-0-5
Heater, 1500W (1)
301-005-001
Belt (1)
288-115-056
Motor, 115V 60Hz (1)
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
275-103-024
Temperature Controller, 100-240V, 1 out
K30165/K30167 Rust Preventing Characteristics Oil Bath,
220-240V, 50Hz..........................................................................Page 98, 128
301-005-001
Belt (1)
K301A-1-0-5
Heater, 1500W (1)
288-230-001
Motor, 230V 50Hz (1)
265-600-001
RTD Temperature Probe, 4 in., 600F
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32 V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K30166/K30168 Rust Preventing Characteristics Oil Bath,
220-240V, 60Hz..........................................................................Page 98, 128
301-005-001
Belt (1)
K301A-1-0-5
Heater, 1500W (1)
288-230-003
Motor, 230V 60Hz (1)
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K31956 Connection Apparatus ...........................................................Page 176
K319-0-6
Condenser
1
⁄2 ID Latex Tubing, 2"
363-102-003
K319-0-9
Tube Connecting Cork
K319-0-10
Thermometer Cork (2)
K319-0-7
End Tube
K319-0-8
Borosilicate Glass Tube
K33700 Existent Gum Evaporation Bath, 6-Unit, 220-240V ..............Page 86
220-240-008
Cartridge Heater, 500W (6)
265-203-001
Temperature Probe, Type “K”, 3⁄16 dia x 4”
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
K337-2-14
Flowmeter
091-032-001
Relay, Solid State, 4-32V DC, 20A
275-103-020
Temperature Controller, 100-240V, 2 out
K33780 Existent Gum Evaporation Bath, 3-Unit, 115V......................Page 86
190-120-005
Heater, Ring, 500W, 120V (3)
265-122-002
RTD Temperature Probe
090-120-014
Relay, SPDT, 120V, 20A
K337-2-14
Flowmeter
275-103-020
Temperature Controller, 100-240V, 2 out
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
091-032-001
Relay, Solid State, 4-32V DC, 20A
K33781 Existent Gum Evaporation Bath, 3-Unit, 220-240V ..............Page 86
190-240-003
Heater, Ring, 500W, 240V (3)
265-122-002
RTD Temperature Probe
091-032-001
Relay, Solid State, 4-32V DC, 20A
K337-2-14
Flowmeter
275-103-020
Temperature Controller, 100-240V, 2 out
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
205
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:42 AM Page 206
Spare Parts (Continued)
K33800 Existent Gum Evaporation Bath w/Superheater,
220-240V ..........................................................................................Pages 86, 87
278-002-001
2A Fuse (2)
220-240-008
Cartridge Heater, 500W (6)
220-240-003
Superheater Cartridge Heater, 1500W (1)
265-203-001
Temperature Probe, Type “K”, 3⁄16 dia x 4”
275-103-032
Temperature Controller, 100-240V
K337-2-14
Flowmeter
275-550-001
Superheater Temperature Controller
265-550-002
RTD Temperature Probe
091-032-001
Relay, Solid State, 90-240V, 20A
K33810 Steam Superheater, 220-240V...............................................Page 87
220-240-003
Cartridge Heater, 1500W (1)
265-550-002
RTD Temperature Probe (1)
K34000/K34010 Viscometer Cleaning & Drying Apparatus ................Page 9
261-104-001
Filter (1)
AS568-015
O-ring (1)
K35000 Corrosion and Oxidation Stability Apparatus, 220-240V...Page 124
220-240-006
Cartridge Heater, 250W (14)
265-203-001
Temperature Probe, Type "K", 3⁄16 dia x 4" (2)
K350-0-23
Test Tube (6)
K350-0-24
Air Tube (6)
K350-0-25
Condenser (6)
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32 V DC, 20A
275-103-024
Temperature Controller, 100-240V, 1 out
K34700 Brookfield Viscosity Air Bath, 115V 60Hz .............................Page 14
278-001-002
Fuse, 1A
278-020-004
Fuse, 20A
278-104-002
Fuse, 0.25A
288-115-059
Motor 115V
091-032-001
Relay, Solid State, 4-32V DC, 20A
271-040-002
Circuit Breaker, 40A
K34701/K34702 Brookfield Viscosity Air Bath, 230V 50/60Hz..........Page 14
278-001-002
Fuse, 1A
278-020-004
Fuse, 20A
278-104-002
Fuse, 0.25A
288-230-020
Motor, 230V 50/60Hz
091-032-001
Relay, Solid State, 4-32V DC, 20A
K35200 Humidity Cabinet for Rust Protection, 115V, 60Hz ..............Page 65
K352-0-22
Heater, 750W (2)
191
RTD Probe Assembly
K35295/K35296 Humidity Cabinet for Rust Protection,
220-240V, 50Hz and 60Hz .................................................................Page 65
K352A-0-22
Heater, 750W (2)
191
RTD Probe Assembly
K39103 Stirrer
289-002-015
289-002-014
K39100-23021
..............................................................................Page 112
Flange Bearing (2)
Bearing (1)
Stirrer Motor
K39179 Conditioning Bath ..................................................................Page 112
K26490-1-5
Control Heater, 1500W (2)
K70519
RTD Temperature Probe, 12 in.
288-230-002
Motor
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
091-032-001
Relay, Solid State, 4-32V DC, 20A
271-025-004
Circuit Breaker, 25A
K39190/K39199 Digital Demulsibility Characteristics Bath,
115V and 220-240V..........................................................................Page 112
265-500-001
RTD Temperature Probe
279-115-002
Lamp
K39180-0-10
Heater, 1000W, 115V
K39189-0-10
Heater, 1000W, 230V
332-001-003
Borosilicate Glass Jar, 12"x18"
K23700-03013A Stirrer Motor, 115V 60Hz
K23700-03014A Motor, 230V 50/60Hz
K39900 LPG Copper Corrosion Water Bath, 115V .............................Page 89
K253-1-0-8
Heater, 750W (1)
275-250-003
Electronic Temperature Controller
191
RTD Probe Assembly
K39990 LPG Copper Corrosion Water Bath, 220-240V......................Page 89
K253-1A-0-8
Heater, 750W (1)
275-250-003
Electronic Temperature Controller
191
RTD Probe Assembly
K40000 LPG Corrosion Test Cylinder...................................................Page 89
AS568-218
O-ring (1)
K42000/K42090 Powertrol Heater, 115V/230V ..................Pages 61, 72, 172
225-115-002
Heater, 1000W, 115V
225-230-002
Heater, 1000W, 230V
010-115-005
Wattstat, 115V
010-230-004
Wattstat, 230V
K43002 Dual Twin Foaming Characteristics Apparatus,
115V...................................................................................................Page 109
K43012
Cylinder and Holder Assembly (4)
265-400-002
RTD Temperature Probe (2)
K43002-0-9
Heater, Outer, 750W (1)
K43002-0-11
Heater, Inner, 750W (1)
K23700-03013A Motor, 115V 60Hz (2)
275-103-029
Temperature Controller, 100-240V (2)
091-120-001
Relay, Solid State, 120V (2)
K430-0-13
Air Outlet Elbow (4)
K430-0-8
Rubber Stopper (4)
278-001-002
Fuse, 1A
K43003 Automatic Time Sequence Foaming Characteristics,
115V...................................................................................................Page 109
K430-0-8
Rubber Stopper (4)
275-103-029
Temperature Controller, 100-240V (2)
265-400-002
RTD Temperature Probe (2)
K23700-03013A Motor, 115V 60Hz (2)
050-002-001
Line Switch (2)
K430-0-13
Air Outlet Elbow (4)
K43002-0-9
Heater, Outer, 750W (1)
K43002-0-11
Heater, Inner, 750W (1)
K43012
Cylinder and Holder Assembly (4)
092-240-001
Timer (3)
278-001-002
Fuse, 1A
091-120-001
Relay, Solid State, 120 V
206
0-198-209_12a_SpareParts_Layout 1 11/1/12 2:21 PM Page 207
Spare Parts (Continued)
K43025 Diffuser Stone Tester.............................................................Page 110
332-003-011
Flask 500mL
K43025-0-5
Stopper
338-000-001
Clamp Holder (2)
337-000-008
Clamp Extension (2)
332-002-016
Graduated Cylinder, 250mL
K43041 Sequence IV Foaming Characteristics Apparatus,
115V...................................................................................................Page 109
K43012
Cylinder and Holder Assembly (2)
K43002-0-9
Heater, Outer, 750W (1)
K43002-0-11
Heater, Inner, 750W (1)
265-400-002
RTD Temperature Probe (1)
K430-0-8
Rubber Stopper (2)
275-103-023
Temperature Controller, 100-240V
K23700-03013A Motor, 115V 60Hz
091-240-002
Relay, Solid State, 90-240V, 25A
090-120-010
Relay, 120V
278-001-002
Fuse, 1A
K43049 Sequence IV Foaming Characteristics Apparatus,
220-240V...........................................................................................Page 109
K43012
Cylinder and Holder Assembly (2)
K43092-0-9
Heater, Outer, 750W (1)
K43092-0-11
Heater, Inner, 750W (1)
K430-0-8
Rubber Stopper (2)
275-103-023
Temperature Controller, 100-240V
265-400-002
RTD Temperature Probe
K23700-03014A Motor, 230V 50/60Hz
090-240-012
Relay, 240V
091-240-004
Relay, Solid State, 240V
278-001-002
Fuse, 1A
K43092 Dual Twin Foaming Characteristics Apparatus, 220-240V.........Page 109
K43012
Cylinder and Holder Assembly (4)
265-400-002
RTD Temperature Probe (2)
K43092-0-9
Heater, Outer, 750W (1)
K43092-0-11
Heater, Inner, 750W (1)
K23700-03014A Motor, 230V 50/60Hz (2)
275-103-029
Temperature Controller, 100-240V (2)
090-240-012
Relay, 240V (2)
K430-0-13
Air Outlet Elbow (4)
091-240-004
Relay, Solid State, 240V
K430-0-8
Rubber Stopper (4)
K43093 Automatic Time Sequence Foaming Characteristics,
220-240V...........................................................................................Page 109
K430-0-8
Rubber Stopper (4)
265-400-002
RTD Temperature Probe (2)
K23700-03014A Motor, 230V 50/60Hz
091-240-004
Relay, Solid State, 240V (2)
050-002-001
Line Switch (2)
K430-0-13
Air Outlet Elbow (4)
K43092-0-11
Heater, Inner, 750W (1)
K43092-0-9
Heater, Outer, 750W (1)
K43012
Cylinder and Holder Assembly (4)
K45090 Front View Distillation Apparatus, Right-Hand, 220-240V .......Page 55
225-230-003
Brick Heater, 1250W (1)
K45100 Front View Distillation Apparatus, Left-Hand, 115V............Page 55
225-115-003
Brick Heater, 1250W (1)
K45190 Front View Distillation Apparatus, Left-Hand, 220-240V....Page 55
225-230-003
Brick Heater, 1250W (1)
K45200 Group 4 Distillation Apparatus, Right-Hand, 115V..............Page 55
K452-0-3
Heater (condenser), 300W (1)
225-115-003
Brick Heater, 1250W (1)
265-550-004
RTD Probe 0.25 OD x 90 deg. bend
K45290 Group 4 Distillation Apparatus, Right-Hand, 220-240V ......Page 55
K452A-0-3
Heater (condenser), 300W (1)
225-230-003
Brick Heater, 1250W (1)
265-550-004
RTD Probe 0.25 OD x 90 deg. bend
K45300 Group 4 Distillation Apparatus, Left-Hand, 115V.................Page 55
K452-0-3
Heater (condenser), 300W (1)
225-115-003
Brick Heater, 1250W (1)
265-550-004
RTD Probe 0.25 OD x 90 deg. bend
K45390 Group 4 Distillation Apparatus, Left-Hand, 220-240V.........Page 55
K452A-0-3
Heater (condenser), 300W (1)
225-230-003
Brick Heater, 1250W (1)
265-550-004
RTD Probe 0.25 OD x 90 deg. bend
Main Part: K45603, K45604, K45703-TS, K45704-TS Automatic
Distillation Analyzer ..............................................................................Page 57
090-240-022
Relay, 230 Vac 10A plug in power
354-040-003
Triac, 40 amp, 600V
220-240-016
Cartridge Heater 300W, 240V
K45658
Heating Element
K45658-A
Ceramic Coil Support, set 4pc.
K45662-A
Fuse, 6.3A Time Lag F220-Pk 10
K45900 Cold Filter Plugging Point Apparatus ..................................Page 100
K459-0-7
Pipette (1)
K459-0-13B
Filter (1)
AS568-008
O-ring (2)
K46000 Cloud and Pour Point Chamber............................................Page 132
K460-1-6
Cover (1)
K460-1-7B
Copper Cup (4)
K460-0-8
Thermometer Holder (4)
K46120
Disc (Cork) Bottom (4)
AS568-219
O-ring (4)
AS568-131
O-ring (4)
K45000 Front View Distillation Apparatus, Right-Hand, 115V .........Page 55
225-115-003
Brick Heater, 1250W (1)
207
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:42 AM Page 208
Spare Parts (Continued)
K46100 Series Refrigerated Cloud and Pour Point,
115V and 220-240V, 50Hz and 60Hz ..............................................Page 132
Model Numbers K46100, K46195, K46196
K46100-03002
Foam Covers
K46100-03030
Copper Test Jacket
091-032-003
Relay
265-400-005
RTD Temperature Probe
275-103-030
Temperature Controller, 1 out
283-120-006
Solenoid Coil, 120-208-240V
283-308-002
Solenoid Valve
278-001-002
Fuse, 1A
K46300 Series Refrigerated Cloud and Pour Point,
115V and 220-240V, 50Hz and 60Hz ..............................................Page 132
Model Numbers K46300, K46395, K46396
K46300-03002
Foam Covers
K46100-03030
Copper Test Jacket
091-032-003
Relay
265-400-005
RTD Temperature Probe
275-103-031
Temperature Controller, 1 out
283-120-006
Solenoid Coil, 120-208-240V
283-308-002
Solenoid Valve
278-001-002
Fuse, 1A
K46600/K46690 Dual Extraction Apparatus,
115V and 220-240V............................................................................Page 60
354-001-003
Rheostat (1)
K47000 Autoignition Apparatus, 220-240V.........................................Page 39
K470-0-1-10
Thermocouple (1)
K470-0-1-15
Thermocouple (3)
332-003-007
500mL Flask (1)
K47500 Wickbold Apparatus, 115V .....................................................Page 58
311-015-003
Pressure Gauge (1)
290-010-001
Pressure Regulator (1)
037-108-00B
Toggle Valve (1)
261-104-001
Filter (1)
K47590 Wickbold Apparatus, 220-240V..............................................Page 58
311-015-003
Pressure Gauge (1)
290-010-001
Pressure Regulator (1)
037-108-00B
Toggle Valve (1)
261-104-001
Filter (1)
240-230-001
Stepdown Transformer (1)
K50100/K50190 Panel Coking Test Apparatus..................................Page 135
275-103-029
Temperature Controller, 100-240V
360-115-014
Motor Control
360-115-009
Tachometer
360-000-002
Digital Pick Up
K299-4-52
Flowmeter
K185-0-66
Motor
381-115-002
Electronic Timer, 115V
381-240-001
Electronic Timer, 240V
265-203-002
Thermocouple
236-115-003
Strip Heater, 400W, 115V
236-230-003
Strip Heater, 400W, 240V
332-017-001
Separatory Funnel, 500mL
220-240-010
Cartridge Heater, 300W, 240V
220-120-008
Cartridge Heater, 300W, 115V
091-240-002
Relay, Solid State, 90-240V, 25A
278-104-003
Fuse, 6A (1)
278-003-001
Fuse, 3.15A
278-002-001
Fuse, 2A (1)
278-001-002
Fuse, 2A (2)
K56100 Cigre Bath, 115V....................................................................Page 126
190-120-009
Ring Heater, 200W (4)
230-115-002
Band Heater, 600W (1)
AS568-213
O-ring (24)
K56110
Oxidation Tubes and Absorption Tubes 12 Sets (2 per set)
265-122-002
RTD Temperature Probe, 3 in., 2 Wire
265-122-003
RTD Temperature Probe, 3 in., 3 Wire
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K56190 Cigre Bath, 220-240V............................................................Page 126
190-240-008
Ring Heater, 200W (4)
230-230-003
Band Heater, 600W (1)
AS568-213
O-ring (24)
K56110
Oxidation Tubes and Absorption Tubes 12 Sets (2 per set)
265-122-002
RTD Temperature Probe, 3 in., 2 Wire
265-122-003
RTD Temperature Probe, 3 in., 3 Wire
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K70000 Oxidation Bomb .....................................................................Page 114
K70050-00000
Silicone O-ring (qty. depends on usage)
K70060
Valve (1)
K70200/K70290 2-Unit RBOT Bath, 220-240V, 50Hz and 60Hz............Page 116
K702-0-8
Control Heater, 1000W (1)
K702-0-8A
Continuous Heater, 1000W (1)
K702-0-8B
Control Heater, 750W (1)
AS568-345-V14 O-Ring, Viton (2)
K700B-0-41
Drive Shaft Seal (8)
K702-CHAIN
Chain Kit (1)
050-230-002
Switch
K700B-0-43
Ball Bearing (2)
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
K70300/K70390 3-Unit RBOT Bath, 220-240V, 50Hz and 60Hz............Page 116
K703-0-8
Heater, 1000W (2)
K703-0-8A
Control Heater, 750W (1)
301-004-001
Vee Belt (1)
AS568-345-V14 O-Ring, Viton (3)
K700B-0-41
Drive Shaft Seal (12)
K703-CHAIN
Chain Kit (1)
K700B-0-43
Ball Bearing (3)
288-115-009
Motor, 1/2 hp
050-230-002
Switch
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
208
0-198-209_12a_SpareParts_Layout 1 10/24/12 11:42 AM Page 209
Spare Parts (Continued)
K70400/K70490 4-Unit RBOT Bath, 220-240V, 50Hz and 60Hz............Page 116
K704-0-8
Heater, 1000W (4)
301-004-001
Vee Belt (1)
AS568-345-V14 O-Ring, Viton (4)
K700B-0-43
Ball Bearing (4)
K700B-0-41
Drive Shaft Seal (16)
K704-CHAIN
Chain Kit (1)
288-115-009
Motor, 1/2 hp
050-230-002
Switch
K70519
RTD Temperature Probe, 12 in.
265-600-001
RTD Temperature Probe, 4 in.
278-020-004
Fuse, 20A
278-001-002
Fuse, 1A
278-104-002
Fuse, 0.25A
KLA-4-TS Automatic Cold Filter Plugging Point System ...............Pages 101
KLA-4S-008-04 CFPP calibrated glass cell
KLA-4S-008-041 “O” ring for CFPP test jar
KLA-4S-008-12 PT100 product w/ connector
KLA-4S-008-13 Calibrated aspiration pipette
KLA-4S-013-01 Filter assembly
KLA-4S-013-02 Filter
KLA-4S-1232
“O” ring (small) for CFPP filter
KLA-4S-1288
“O” ring for CFPP filter
KLA-5-TS Automatic Freezing Point System....................................Pages 97
KLA-5S-008-07 Fiber optic for Freezing point
KLA-5S-008-12A Removable freezing glass cell
K87100/K87190 Automatic Pensky-Martens
Closed Cup Flash Point Tester............................................................Pages 33
K87100-5
Stirring Connection Cable
K87100-6
Detection Cable
K87100-7
PT 100 Probe
K87100-8
Electric Ignitor (consumable)
K87100-9
Roll of Printer Paper (consumable)
K87400/K87490 Automatic Cleveland Open
Cup Flash Point Tester ........................................................................Pages 33
K87400-3
Heating Element 1000W
K87400-4
Electric Ignitor (consumable)
K87400-5
Roll of Printer Paper (consumable)
K87400-8
Insulated Plate-Mobile
K87400-9
PT 100 Probe
K88600 Portable Octane Analyzer....................................................Pages 102
K88603
Sample Holder
K88615
Serial to USB adapter
K88608
Sample holder covers, 12
K95500/K95590 Digital Penetrometer ..................................Pages 24, 25, 27
277-001-001
Fuse Holder and Cap
278-004-001
Fuse, 4A
459-012-001
Battery, 12V (1)
K95500-02001
Light Assembly
KLA-1-TS Automatic Cloud Point System ...............................................Page 133
KLA-1S-008-04 Calibrated glass cell for cloud (silver bottom)
KLA-1S-008-041 “O” ring for CP test jar
KLA-1S-008-06 Fiber optic for cloud point
KLA-1S-008-12 PT100 product w/ connector (white)
KLA-2-TS Automatic Pour Point System .........................................Pages 133
KLA-2S-008-04 Pour Point glass cell
KLA-2S-008-041 “O” ring for PP test jar
KLA-2S-008-12 PT100 product w/ connector (white)
KLA-2S-008-13 PT100 detection w/ connector (brown)
KLA-3-TS Automatic Cloud/Pour Point System...............................Pages 133
KLA-3S-008-06 Fiber optic for Cloud Point
KLA-3S-008-12A PT100 product w/ connector (blue)
KLA-2S-008-13 PT100 detector w/ connector (brown)
KLA-1S-008-04 Calibrated Glass Cell for Cloud Point (silver bottom)
209
0-210-214_12b_CatalogNumberIndex_Layout 1 10/24/12 11:44 AM Page 210
Catalog Number Index
Cat. No.
Page
K10020 ................................43
K10029 ................................43
K10090 ................................43
K10091 ................................43
K10190 ................................43
K10191 ................................43
K10200 ................................42
K10210 ................................42
K10220 ................................42
K10290 ................................42
K10400 ................................82
K10401 ................................81
K10402 ................................82
K10403 ................................81
K10404 ................................82
K10491 ................................81
K10493 ................................81
K10500 ................................80
K10504-0-1.................84, 153
K10504-XP ..........................84
K10505-XP ..........................84
K10506-XP ..........................84
K10510 ..........................81, 82
K10520 ..........................81, 82
K10525 ..........................81, 82
K10530 ..........................81, 82
K10540....................81, 82, 85
K10540/C.......................81, 82
K10551..................81, 82, 153
K10556..................81, 82, 153
K10560 ..........................81, 82
K10570 ................................84
K10580 ................................84
K10590 ................................84
K10594-XP ..........................84
K10595-XP ..........................84
K10596-XP ..........................84
K10600 ................................85
K10601 ................................85
K10602 ................................85
K10901 ..............................153
K10991 ..............................153
K11000 ..............................153
K11005 ..............................153
K11029 ..............................153
K11040 ..............................153
K11095 ..............................153
K11201 ................................92
K11202 ................................92
K112B-1-0-12......................94
K11401 ................................93
K11404-50...........................93
K11404-200.........................93
K11404-1000.......................93
Cat. No.
Page
K11415 ................................93
K11416 ................................93
K11450 ................................93
K11459 ................................93
K11491 ................................93
K11500 ................................92
K11800 ................................94
K11810 ................................94
K12100 ..............................123
K12130 ..............................123
K12190 ..............................123
K12200 ..............................120
K12201 ..............................121
K12210 ..............................122
K12212 ..............................120
K12219 ..............................120
K12230 ..............................119
K12239 ..............................119
K12250 ..............................122
K12260 ..............................122
K12281 ..............................122
K12290 ..............................120
K122-0-18..........................122
K122-0-19..........................122
K122-0-20..........................122
K122-0-21..........................122
K122-0-22..........................122
K122-0-23..........................122
K122-0-27..........................122
K122-0-28..........................122
K122-0-30..........................122
K1223-3L...........................119
K1223-10L.........................119
K1223-R943 ......................119
K1223-R2440....................119
K1223-R4636....................119
K12300 ..............................121
K12330 ..............................121
K12339 ..............................121
K12395 ..............................121
K13009 ................................44
K13010 ................................44
K13020 ................................44
K13029 ................................44
K13032 ................................44
K13033 ................................44
K13100 ................................44
K13150 ................................46
K13190 ................................44
K13200 ................................45
K13203 ................................45
K13204 ................................45
K13205 ................................45
K13210 ................................45
Cat. No.
Page
K13223 ................................45
K13250-1.............................47
K13253 ................................47
K13260 ................................46
K13290 ................................45
K13294 ................................45
K13349 ................................47
K13351...........................46-47
K13353...........................46-47
K13356 ................................47
K13500-3.............................47
K13550 ................................47
K13550-1.......................46, 47
K13551 ..........................46, 47
K13552 ................................47
K13553 ................................47
K13554 ................................47
K13900 ................................36
K13990 ................................36
K14000 ................................36
K14510 ................................35
K14520 ................................35
K14600 ................................35
K14670 ...............................35
K14690 ................................35
K15520 ................................37
K15600 ................................37
K15610 ................................37
K15620 ................................37
K15670 ................................37
K15690 ................................37
K16000 ................................34
K16010 ................................34
K16020 ................................34
K16020-NI ...........................34
K16175 ..............................134
K16175-4...........................134
K16175-5...........................134
K16175-6...........................134
K16175-12.........................134
K16175-13.........................134
K16175-14.........................134
K16175-23.........................134
K16175-24.........................134
K16200 ................................34
K16220 ................................34
K16228 ................................34
K16229 ................................34
K16270 ................................34
K16500 ................................38
K16502 ................................38
K16503 ................................38
K16504 ................................38
K16506 ................................38
210
Cat. No.
Page
K16507 ................................38
K16508 ................................38
K16509 ................................38
K16510 ................................38
K16511 ................................38
K16512 ................................38
K16513 ................................38
K16514 ................................38
K16515 ................................38
K16516 ................................38
K16517 ................................38
K16591 ................................38
K16592 ................................38
K16593 ................................38
K16594 ................................38
K17000 ..............................174
K17090 ..............................174
K17100 ..............................177
K17110 ..............................177
K17190 ..............................177
K17200 ..............................177
K17290 ..............................177
K17300 ..............................177
K17390 ..............................177
K17500 ..............................178
K175-0-8............................178
K17600 ..............................179
K17605 ..............................179
K17690 ..............................179
K17695 ..............................179
K17700 ................................26
K17710 ................................26
K17770 ................................26
K17900 ..............................154
K17910 ..............................154
K17920 ..............................154
K17930 ..............................154
K17970 ..............................154
K17979 ..............................154
K17980 ..............................154
K17981 ..............................154
K17981-0-2 .......................154
K17981-0-3 .......................154
K17982 ..............................154
K17983 ..............................154
K17984 ..............................154
K17989 ..............................154
K18000 ................................28
K18020 ................................28
K18021 ................................28
K18022 ................................28
K18023 ................................28
K18028 ................................28
K18029 ................................28
Cat. No.
Page
K18030 ................................28
K18100 ..........................26, 28
K18110 ................................28
K18119 ................................28
K18190 ................................28
K18191 ................................28
K18192 ................................28
K18200 ..............................163
K18210 ..............................163
K18220 ..............................163
K18290 ..............................163
K18295 ..............................163
K18300........................27, 156
K18305 ..............................156
K18306 ..............................156
K18320 ..............................156
K18325 ..............................156
K18326 ..............................156
K18340 ..............................156
K18341 ..............................156
K18345 ..............................156
K18346 ..............................156
K18347 ..............................156
K18348 ..............................156
K183-0-1A .........................156
K183-0-4............................156
K18500 ..............................161
K18590 ..............................161
K18595 ..............................161
K18650 ..............................127
K18660 ..............................127
K18661 ..............................127
K18700 ..............................160
K18723 ..............................160
K18790 ..............................160
K18795 ..............................160
K18850 ..............................159
K18851 ..............................159
K18852 ..............................159
K18853 ..............................159
K18854 ..............................159
K18855 ..............................159
K18860 ..............................159
K18860-0-16 .....................159
K18860-0-24 .....................159
K18861 ..............................159
K18862 ..............................159
K18863 ..............................159
K18864 ..............................159
K18865 ..............................159
K18871 ..............................159
K18900 ..............................165
K18910 ..............................165
K18919 ..............................165
0-210-214_12b_CatalogNumberIndexAA4_Layout 1 11/30/12 5:05 PM Page 211
Catalog Number Index (Continued)
Cat. No.
Page
K19000 ..............................164
K190-0-1C .........................164
K190-0-5............................164
K19050 ..............................164
K19100 ................................26
K19200 ..............................162
K19290 ..............................162
K19295 ..............................162
K192-1-4............................162
K192-1-6............................162
K19300 ..............................166
K19310 ..............................166
K19400 ..............................151
K19410 ..............................151
K19490 ..............................150
K19491 ..............................150
K19492 ..............................150
K19493 ..............................150
K19499 ..............................150
K194EA......................150, 151
K194EB ..............................151
K194EC ..............................151
K194E1 ..............................151
K194E2 ..............................151
K194E3 ..............................151
K194E4 ..............................151
K194E5 ..............................151
K194E6......................150, 151
K194E7......................150, 151
K19500 ................................24
K19510 ................................24
K19520 ..........................24, 27
K19525 ................................24
K19535 ................................24
K19536 ................................24
K19552 ..........................24, 25
K19553 ..........................24, 25
K19587 ................................25
K19588 ................................25
K19800 ................................27
K19900 ................................27
K20000 ................................26
K20090 ................................27
K20200 ................................27
K20210 ................................27
K20300 ................................27
K20500-00000.....................26
K20570-00000.....................26
K20600-00000.....................26
K20670-00000.....................26
K20700 ................................27
K20800 ..........................26, 27
K20900 ................................27
K20910 ..........................24, 27
Cat. No.
Page
K21000 ................................27
K21001 ................................27
K21002 ................................27
K21404 ................................16
K21410 ..........................16, 17
K21414 ................................16
K21420 ................................16
K21424 ................................16
K21494 ................................16
K22009 ................................17
K22010 ................................17
K22010-C/F..........................17
K22011 ................................17
K22020 ................................17
K22020-C/F..........................17
K22029 ................................17
K22030 ................................17
K22039 ................................17
K22050 ................................17
K22060 ................................17
K22070 ................................17
K22080 ................................17
K22090 ................................17
K22309 ................................17
K22600 ..............................157
K22610 ..............................157
K22615 ..............................157
K22680 ..............................158
K22680-0-16 .....................158
K22680-0-22 .....................158
K22685 ..............................158
K22686 ..............................158
K22690 ..............................157
K22690-0-27 .....................157
K22695 ..............................157
K22696 ..............................157
K226-0-16..........................157
K226-0-22..........................157
K22751...................................7
K22751-OS ............................7
K22752...................................7
K22752-OS ............................7
K22753...................................7
K22753-OS ............................7
K22754...................................7
K22754-OS ............................7
K23050 ................................61
K23050-9.............................61
K23050-10...........................61
K23350...................................8
K23351...................................8
K23363...................................8
K23371-00000.......................3
K23376-00000.......................3
Cat. No.
Page
K23377-00000.......................3
K23377-01000.......................3
K23378-00000.......................3
K23381...................................8
K23381-HT ............................8
K23382...................................8
K23382-HT ............................8
K23383...................................8
K23384...................................8
K23387...................................8
K23388...................................8
K23462...................................8
K23463 ................................13
K23464 ................................13
K23465 ................................13
K23466 ................................13
K23467 ................................12
K23700...................................4
K23702...................................4
K23702-OS ............................5
K23706...................................4
K23708...................................4
K23708-OS ............................5
K23780-CF.............................5
K23780-RF.............................5
K23780-SFW .........................5
K23780-UB ............................5
K23780-WLS .........................5
K23790...................................4
K23792...................................4
K23792-OS ............................5
K23796...................................4
K23798...................................4
K23798-OS ............................5
K23800...................................6
K23802...................................6
K23890...................................6
K23892...................................6
K24000 ..............................122
K24305 ................................63
K24306 ................................63
K24307 ................................63
K24308 ................................63
K24395 ................................63
K24396 ................................63
K24397 ................................63
K24398 ................................63
K25000...89, 91, 99, 131, 155
K25080................91, 131, 155
K25090..................89, 91, 131
K25100 .........89, 91, 131, 155
K25200 ..........................91, 99
K25280 ................................99
K25282 ................................99
211
Cat. No.
Page
K25308 ..............................155
K25309 ................................90
K25310....................90, 91, 99
K25312 ..............................131
K25319....................90, 91, 99
K25320 ................................90
K25329 ................................90
K25330 .........90, 91, 131, 155
K25330-8B...........................90
K25330-4B-8T.....................90
K25330-6B-6T.....................90
K25339 .........90, 91, 131, 155
K25360 ................................99
K25370 ................................99
K25501 ..............................166
K25502 ..............................166
K25507 ..............................166
K25509 ..............................166
K25551-1...........................166
K25551-2...........................166
K25551-3...........................166
K25552 ..............................166
K25900 ..............................103
K25990 ..............................103
K25995 ..............................103
K26150 ..............................103
K26200 ................................50
K26290 ................................50
K26300 ................................49
K26390 ................................49
K26400 ................................50
K26410 ................................50
K26490 ................................50
K26500 ................................74
K26501 ................................74
K26502 ................................74
K26503 ................................74
K26590 ................................74
K27000 ................................95
K27010 ................................95
K27020 ................................95
K27021 ................................95
K27050 ................................95
K27060 ................................95
K27065 ................................95
K27100 ................................59
K27190 ................................59
K27200 ................................59
K27320 ................................59
K27400 ................................67
K27401 ................................67
K27504 ................................73
K27505 ................................73
K27550 ................................73
Cat. No.
Page
K27560 ................................73
K27600 ................................67
K27601 ................................67
K27610 ................................67
K27700 ................................66
K27701 ................................66
K27760 ................................66
K27761 ................................66
K27762 ................................66
K27770 ................................66
K27771 ................................66
K27772 ................................66
K27780 ................................66
K27781 ................................66
K27782 ................................66
K27785 ................................66
K27790 ................................66
K27791 ................................66
K27792 ................................66
K27795 ................................66
K277-EXT1...........................66
K277-EXT2...........................66
K277-EXT3...........................66
K277-EXT6...........................66
K277-EXT12.........................66
K277-EXT18.........................66
K277C-EXT1 ........................66
K277C-EXT2 ........................66
K277C-EXT3 ........................66
K277C-EXT6 ........................66
K277C-EXT12 ......................66
K277C-EXT18 ......................66
K27800 ................................66
K27851 ................................67
K27852 ................................67
K27853 ................................67
K27854 ................................67
K27856 ................................67
K27900 ................................66
K28100 ................................67
K28300 ..............................172
K28310 ..............................172
K28320 ..............................172
K28321 ..............................172
K29300 ..............................149
K29310................59, 149, 177
K29319 .......59, 125, 149, 177
K29320 ..............................149
K29329 ..............................149
K293-0-12..........................125
K29400 ..............................148
K29490 ..............................148
K29500 ..............................148
K29530......................148, 149
0-210-214_12b_CatalogNumberIndexAA4_Layout 1 11/30/12 5:05 PM Page 212
Catalog Number Index (Continued)
Cat. No.
Page
K29540......................148, 149
K29550 ..............................148
K29700 ................................96
K29720 ................................96
K29721 ................................96
K29750 ................................68
K29750-1-7..........................96
K29758 ................................68
K29758-0-7..........................96
K29759 ................................68
K29759-1-7..........................96
K29760 ................................94
K29768 ................................94
K29769 ................................94
K29790 ................................96
K29795 ................................96
K29796 ................................96
K29800 ..............................131
K29801 ..............................131
K2983-2 ...............................15
K29900 ..............................130
K29910 ..............................130
K29920 ..............................130
K29930 ..............................130
K29990 ..............................130
K30000 ..............................130
K30010 ..............................130
K30100........................98, 129
K30101........................98, 129
K30110........................98, 129
K30119 ..............................129
K30130..................88, 98, 129
K30140 ..............................129
K30150..................88, 98, 129
K30160 ..............................128
K30160NACE.......................98
K30161 ..............................128
K30165 ..............................128
K30165NACE.......................98
K30166 ..............................128
K30166NACE.......................98
K30167 ..............................128
K30168 ..............................128
K30180........................88, 129
K30260 ................................88
K30269 ................................88
K30500 ..............................176
K30510 ..............................176
K30520 ..............................176
K30800 ..............................129
K30810 ..............................129
K30820 ..............................129
K31800 ................................72
K31810 ................................72
Cat. No.
Page
K31820 ................................72
K31830 ................................72
K31900 ..............................176
K31910........................72, 176
K31956 ..............................176
K32230 ................................88
K32230-1.............................88
K32230-2.............................88
K32230-3.............................88
K32230-4.............................88
K33031 ..............................110
K33032 ..............................110
K33050 ................................70
K33051 ................................70
K33052 ................................70
K33053 ................................70
K33054 ................................70
K33055 ................................70
K33056 ................................70
K33057 ................................70
K33058 ................................70
K33059 ................................70
K33060 ................................70
K33061 ................................70
K33062 ..........................53, 71
K33063 ..........................53, 71
K33064 ................................71
K33065 ................................71
K33066 ................................71
K33067 ................................71
K33068 ................................71
K33069 ................................71
K33070 ................................71
K33071 ................................71
K33072 ................................71
K33073 ................................71
K33700 ................................86
K33710 ................................87
K33780 ................................86
K33781 ................................86
K33800 ..........................86, 87
K33810 ................................87
K33850 ................................87
K33850 Series .....................87
K33850/208601...................87
K33850/208603...................87
K33850/240601...................87
K33850/240603...................87
K33850/380603...................87
K33850/415503...................87
K33850/480603...................87
K34000...................................9
K34010...................................9
K34700 ................................14
Cat. No.
Page
K34701 ................................14
K34702 ................................14
K34706 ................................15
K34707 ................................15
K34708 ................................15
K34709 ................................15
K34710 ................................14
K34711 ................................14
K34712 ................................14
K34715 ................................15
K34716 ................................15
K34770 ................................15
K34779 ................................15
K35000 ..............................124
K35010 ..............................125
K35011 ..............................125
K35012 ..............................125
K35013 ..............................125
K35020 ..............................125
K35030 ..............................125
K35040 ..............................125
K35050 ..............................125
K35060 ..............................125
K35070 ..............................125
K35080 ..............................125
K35090 ..............................125
K35095 ..............................125
K350-0-23..........................125
K350-0-24..........................125
K350-0-25..........................125
K35100 ..............................124
K35110 ..............................125
K35120 ..............................125
K35130 ..............................125
K35140 ..............................125
K35150 ..............................125
K35160 ..............................125
K35170 ..............................125
K351-0-1............................125
K351-0-2............................125
K351-0-3............................125
K351-0-4............................125
K351-0-5............................125
K351-0-6............................125
K351-0-7............................125
K351-0-8............................125
K351-0-13..........................125
K351-0-14..........................125
K35200 ................................65
K35210 ................................65
K35295 ................................65
K35296 ................................65
K35300 ..............................124
K353-0-1............................125
212
Cat. No.
Page
K353-0-2............................125
K353-0-3............................125
K353-0-4............................125
K353-0-5............................125
K353-0-6............................125
K353-0-7............................125
K353-0-8............................125
K39103 ..............................112
K39120 ..............................112
K39130 ..............................112
K39140 ..............................112
K39149 ..............................112
K39150 ..............................112
K39170 ..............................112
K39179 ..............................112
K39190 ..............................112
K39199 ..............................112
K39251 ..............................111
K39252 ..............................111
K39400 ..............................111
K39496 ..............................111
K39900 ................................89
K39990 ................................89
K40000 ................................89
K40100 ..........................89, 94
K40200 ................................89
K41500-4...........................104
K41500-5...........................104
K41502 ..............................104
K41504 ..............................104
K41506 ..............................104
K41579 ..............................104
K41580 ..............................104
K41592 ..............................104
K41594 ..............................104
K41596 ..............................104
K42000..................61, 72, 172
K42001 ................................72
K42090..................61, 72, 172
K42091 ................................72
K43002......................109, 110
K43003 ..............................109
K43005......................109, 110
K43012 ..............................110
K43025 ..............................110
K43026 ..............................110
K43041......................109, 110
K43049 ..............................109
K43092 ..............................109
K43093 ..............................109
K43095 ..............................109
K44100 ..............................136
K44100-1...........................136
K44100-2...........................136
Cat. No.
Page
K44100-3...........................136
K44100-SFW .....................136
K44190 ..............................136
K447-BH ..............................21
K447-BL.........................15, 21
K447-BR ..............................21
K447-HDU............................21
K447-LVA.............................21
K447-LVA-CJ .......................21
K447-MH .............................21
K447-MH-SFW ....................21
K447-ML..............................21
K447-ML-SFW.....................21
K447-MR .............................21
K447-MR-SFW ....................21
K447-PH ..............................21
K447-PL.........................15, 21
K447-PR ..............................21
K447-SH ..............................21
K447-SH-PT.........................21
K447-SL...............................21
K447-SL-PT.........................21
K447-SP-LVA.......................21
K447-SR ..............................21
K447-SR-PT.........................21
K447-SSA ............................21
K447-SSA-CJ.......................21
K447-SSP-SETL ..................21
K447-SSP-SETRH ...............21
K45000 ................................55
K45090 ................................55
K45100 ................................55
K45190 ................................55
K45200 ................................55
K45290 ................................55
K45300 ................................55
K45390 ................................55
K45410 ................................55
K45420 ................................55
K45430 ................................55
K45440 ................................55
K45540 ................................55
K45601-03014.....................57
K45603 ................................57
K45604 ................................57
K45634 ................................57
K45635 ................................57
K45650 ................................57
K45651-B.............................57
K45651-E.............................57
K45652-C.............................57
K45654 ................................57
K45654-A.............................57
K45655 ................................57
0-210-214_12b_CatalogNumberIndexAA4_Layout 1 11/30/12 5:05 PM Page 213
Catalog Number Index (Continued)
Cat. No.
Page
K45656 ................................57
K45656-A.............................57
K45657 ................................57
K45668 ................................57
K45703-TS...........................57
K45704-TS...........................57
K45850 ..............................174
K45859 ..............................174
K45900 ..............................100
K45910 ..............................100
K45920 ..............................100
K45950 ..............................100
K45995 ..............................100
K46000 ..............................132
K46001 ..............................132
K460-0-8 ...................132, 155
K460-1-7B .........................132
K46100 ..............................132
K46120 ..............................132
K46130 ..............................132
K46195 ..............................132
K46196 ..............................132
K46300 ..............................132
K46395 ..............................132
K46396 ..............................132
K46500 ..............................132
K46595 ..............................132
K46596 ..............................132
K46600 ................................60
K46690 ................................60
K47000 ................................39
K470-0-1-8 ..........................39
K470-0-1-14 ........................39
K47100 ................................52
K47190 ................................52
K47500 ................................58
K47510 ................................58
K47520 ................................58
K47530 ................................58
K47540 ................................58
K47550 ................................58
K47560 ................................58
K47570 ................................58
K47580 ................................58
K47590 ................................58
K48100 ..............................105
K481-0-5............................105
K48300 ................................61
K48400 ................................61
K48500 ................................61
K48600 ................................61
K48700 ................................61
K50100 ..............................135
K50101 ..............................135
Cat. No.
Page
K50102 ..............................135
K50110 ..............................135
K50119 ..............................135
K50190 ..............................135
K56100 ..............................126
K56110 ..............................126
K56190 ..............................126
K56200 ..............................126
K56290 ..............................126
K56300 ................................68
K56306 ................................68
K56390 ................................68
K60002 ................................62
K60002-FT ...........................62
K60002-FT-1........................62
K60002-LT-1........................62
K60002-PT...........................62
K60002-PT-1 .......................62
K60002-ST...........................62
K60002-ST-1 .......................62
K60005 ................................63
K60005-FT ...........................63
K60006 ................................63
K60006-FT ...........................63
K60092 ................................62
K60092-FT ...........................62
K60092-PT...........................62
K60092-ST...........................62
K60094 ................................63
K60095 ................................63
K60095-FT ...........................63
K60096 ................................63
K60096-FT ...........................63
K61101 ................................62
K61102 ..........................62, 63
K61104 ................................62
K61105 ..........................62, 63
K61106 ................................62
K61107 ..........................62, 63
K61108 ..........................62, 63
K61109 ................................62
K61110 ................................62
K61111 ..........................62, 63
K61112 ................................62
K61141 ..........................62, 63
K61152 ................................62
K61153 ................................62
K70000 ..............................114
K70000-03008 ..................117
K70002 ..............................117
K70003 ..............................117
K70004 ..............................117
K70010/24.........................117
K70011 ..............................117
Cat. No.
Page
K70012 ..............................117
K70013 ..............................117
K70015-1A...........................39
K70017 ..............................117
K70018 ..............................117
K70030 ..............................117
K70040 ..............................117
K70048 ..............................117
K70049 ..............................117
K70050 ..............................117
K70080 ..............................117
K70081-1...........................117
K70082 ..............................117
K70090 ..............................117
K70091 ..............................117
K70092 ..............................114
K70093 ..............................117
K70095 ..............................117
K700-0-3A .........................117
K70200 ..............................116
K70290 ..............................116
K70300 ..............................116
K70390 ..............................116
K70400 ..............................116
K70490 ..............................116
K70500 ..............................118
K70502-XP ........................115
K70502RETRO ..................118
K70503-XP ........................115
K70503RETRO ..................118
K70504-XP ........................115
K70504RETRO ..................118
K70519........................84, 118
K70592-XP ........................115
K70592RETRO ..................118
K70593-XP ........................115
K70593RETRO ..................118
K70594-XP ........................115
K70594RETRO ..................118
K80000 ..............................172
K80001 ..............................172
K80002 ..............................172
K80003 ..............................172
K80012 ..............................170
K80013 ..............................170
K80030 ................................60
K80031 ................................60
K80032 ................................60
K80033 ................................60
K80034 ................................60
K80034-WT .........................60
K80035 ................................60
K80036 ................................60
K80039 ................................60
213
Cat. No.
Page
K80041 ..............................170
K80050 ..............................170
K80050-SFW .....................170
K80060 ..............................170
K80068 ..............................170
K80069 ..............................170
K80300 ................................53
K80320 ................................53
K80390 ................................53
K83100 ................................77
K86200 ................................64
K86201 ................................64
K86202 ................................64
K86203 ................................64
K86204 ................................64
K86206 ................................64
K86207 ................................64
K86208 ................................64
K86209 ................................64
K86210 ................................64
K87100 ................................33
K87170 ................................54
K87180 ................................54
K87190 ................................33
K87300 ................................33
K87390 ................................33
K87400 ................................33
K87490 ................................33
K87700 ................................33
K87790 ................................33
K87800 ..............................171
K87800-1...........................171
K87800-2...........................171
K87800-3...........................171
K87800-4...........................171
K87800-5...........................171
K87800-6...........................171
K87800-7...........................171
K87800-8...........................171
K87800-9...........................171
K87800-10.........................171
K87890 ..............................171
K88000 ..............................175
K88000-1...........................175
K88000-2...........................175
K88001 ..............................175
K88100 ..............................173
K88100-1...........................173
K88100-2...........................173
K88100-3...........................173
K88100-4...........................173
K88100-5...........................173
K88100-6...........................173
K88500 ..............................113
Cat. No.
Page
K88501 ..............................113
K88502 ..............................113
K88600 ..............................102
K88600-GPS......................102
K88601 ..............................102
K88602 ..............................102
K88603 ..............................102
K88604 ..............................102
K88605 ..............................102
K88606 ..............................102
K88607 ..............................102
K88608 ..............................102
K88609 ..............................102
K88610 ..............................102
K88612 ..............................102
K88613 ..............................102
K88800 ................................76
K88800-1.............................76
K88800-2.............................76
K88800-3.............................76
K88800-4.............................76
K88800-5.............................76
K88890 ................................76
K88890-1.............................76
K90100 ................................69
K90100-1.............................69
K90100-2.............................69
K90100-3.............................69
K90190 ................................69
K90365 ................................51
K90365-7.............................51
K90365-8.............................51
K90365-20...........................51
K90365-35...........................51
K90365-36...........................51
K90500 ................................75
K90500-1.............................75
K90500-2.............................75
K90500-3.............................75
K90500-4.............................75
K90500-5.............................75
K90500-6.............................75
K90590 ................................75
K90601 ................................74
K90602 ................................74
K90603 ................................74
K90691 ................................74
K90692 ................................74
K90693 ................................74
K92000 ..............................143
K92000-PN........................143
K92090 ..............................143
K92090-PN........................143
K93000 ..............................144
0-210-214_12b_CatalogNumberIndexAA4_Layout 1 11/30/12 5:05 PM Page 214
Catalog Number Index (Continued)
Cat. No.
Page
K93004 ..............................144
K93016 ..............................144
K93090 ..............................144
K93100 ..............................140
K93100-PN........................140
K93105 ..............................140
K93111 ..............................140
K93190 ..............................140
K93190-PN........................140
K93450 ..............................141
K93459 ..............................141
K93500 ..............................142
K93590 ..............................142
K93600 ..............................146
K93690 ..............................146
K93900 ..............................141
K94190 ..............................145
K94400 ..............................144
K94401 ..............................144
K94402 ..............................144
K94403 ..............................144
K94408 ..............................144
K94410 ..............................144
K94490 ..............................144
K94490-1...........................144
K95190 ..............................145
K95400 ..............................167
K95400-1...........................167
K95500-00000.....................25
K95519-00000 ..............25, 27
K95573-00000 ..............25, 27
K95577 ................................25
K95590-00000.....................25
K95600....................26, 27, 29
K95690....................26, 27, 29
KLA-1-TS ...........................133
KLA-1-TS/2........................133
KLA-1820-8013...................76
KLA-2-TS ...........................133
KLA-2-TS/2........................133
KLA-3-TS ...........................133
KLA-3-TS/2........................133
KLA-4-TS ...........................101
KLA-4-TS/2........................101
KLA-4-IVPS .......................101
KLA-4-VPS (115) ..............101
KLA-4-VPS (220) ..............101
KLA-5-TS .............................97
KLA-5-TS/2..........................97
KLA-6...................................76
KLA-6 (220).........................76
KLA-7.................................105
KLA-7 (220).......................105
KLA-1820-8013.................176
Cat. No.
Page
KLA-DB-KIT .........76, 97, 101,
105, 133, 136
KLA-PT100-CAL ..76, 97, 101,
105, 133, 136
250-000-15C .....................172
250-000-15F......................172
250-000-16C .....................172
250-000-16F......................172
250-000-XXF Series ..184-191
250-000-XXC Series184-191
250-000-33C .....................172
250-002-001......................122
250-004-XXF Series ..184-191
250-004-XXC Series..184-191
250-100-001......................158
251-000-001......................103
251-000-004......................103
251-000-01H Series............48
251-000-21H Series............48
251-000-51H Series............48
251-000-71H Series............48
251-000-82H Series............48
251-000-102H Series..........49
251-000-300H Series..........49
279-115-005........................44
279-230-002........................44
289-001-006 .............159, 162
289-004-001......................161
289-004-002 .............154, 161
289-004-003......................160
289-004-004......................160
308-000-004......................117
308-000-005........................84
308-001-02B .......................84
308-001-02R .......................84
308-001-L2R .......................84
308-230-009......................159
311-005-004........................92
311-015-002........................92
311-030-002........................92
311-060-002........................92
311-100-002........................92
311-160-003......................153
311-250-001........................92
311-600-003........................92
332-002-003 ...............55, 176
332-002-006......................129
332-002-007........................98
332-002-008......................164
332-002-009......................165
332-002-011........................49
332-002-013........................55
332-002-014........................55
332-002-017........................87
Cat. No.
Page
332-002-018......................111
332-003-001........................55
332-003-002........................55
332-003-003........................17
332-003-005........................55
332-003-006........................55
332-003-008........................39
332-003-014........................17
332-004-001 .............132, 155
332-004-002.......91, 131, 155
332-004-004.........91, 99, 131
332-004-009......................179
332-005-005......................110
332-005-010......................123
332-005-011......................123
332-007-001........................59
332-010-001......................105
334-002-001........................55
334-002-002........................55
334-002-003........................55
337-000-002......................105
338-000-001......................105
339-000-001......................105
344-005-001......................110
344-005-01C .....................110
344-100-001......................110
344-100-01C .....................110
355-001-001...8, 17, 123, 153
355-001-002 .............8, 16, 17
355-001-003.........8, 123, 153
355-001-004 ...................8, 16
355-002-003........................18
355-002-006........................18
355-002-020........................18
355-002-060........................18
355-002-200........................18
355-002-203........................18
355-002-304........................18
355-002-600........................18
355-002-803........................18
355-003-005........................18
355-003-010........................18
355-003-103........................18
355-003-500........................18
355-003-503........................18
355-003-752........................18
355-004-001........................18
355-004-004........................18
355-004-008........................18
355-004-010........................18
355-004-035........................18
355-004-100........................18
355-004-103 .................18, 19
355-004-153 .................18, 19
214
Cat. No.
Page
355-004-154........................19
355-004-194........................19
355-004-203........................19
355-004-275........................19
355-004-304........................19
355-004-350........................18
355-004-403 .................18, 19
355-004-454........................19
355-004-600........................19
355-004-623........................19
355-004-803........................19
355-005-010........................19
355-005-012........................19
355-005-014........................19
355-005-016........................19
355-005-019........................19
355-005-022........................19
355-005-025........................19
355-005-027 .................15, 19
355-005-028........................19
355-005-032........................19
355-005-038........................19
355-005-048........................19
355-005-060........................19
355-005-074........................19
355-005-115 .................15, 19
357-000-001........................26
360-000-003......................112
362-001-000........................39
362-001-001......................105
362-010-001........................59
371-000-002........................94
374-115-001........................39
374-230-001........................39
378-000-C03 Series ............11
378-001-C08 Series ............12
378-001-C09 Series ............12
378-001-C19 Series ............13
378-001-C20 Series ............13
378-001-C21 Series ............13
378-00A-C08 Series............12
378-004-C13 Series ............13
378-025-C01 Series ............10
378-025-C01-OS Series........5
378-025-C02 Series ............11
378-025-C02-OS Series........5
378-000-C03-OS Series........5
378-025-C06 Series ............13
378-025-C10 Series ............12
378-025-C11 Series ............11
378-025-C12 Series ............11
378-025-C14 Series ............13
378-025-C15 Series ............11
378-025-C16 Series ............11
Cat. No.
Page
378-025-C17 Series ............12
378-0M1-C18 Series...........12
380-100-001 ...............98, 122
380-150-000 ................89, 99,
125, 155
380-150-001 ...............89, 99,
125, 127, 131, 155
380-150-002......................129
380-150-003 ..............91, 131
380-220-001 ..............91, 131
380-240-001..89, 99, 125, 155
380-240-002 ...............65, 129
382-018-001........................59
387-115-001......................110
387-230-001......................110
388-001-003 ...............26, 174
388-001-006........................26
AS568-113...........................94
AS568-210...........................94
AS568-219.........................132
AS568-009-V14.................122
0-215-218_12c_TestMethods_Layout 1 10/24/12 11:45 AM Page 215
Test Method Standards Index
American Society for Testing and Materials (ASTM) Methods
Standard
Page No.
ASTM Draft Method..................154, 158
C70.....................................................192
C128...................................................192
C135...................................................192
C188...................................................192
D5.............................................24-26, 29
D6.......................................................174
D20.....................................................192
D29.....................................................192
D36 ............................................171, 172
D56........................................33, 35, 182
D70.....................................................192
D86.........................................55-57, 182
D87.....................................................178
D88 .................................................16-17
D91.......................................................62
D92........................................33, 36, 182
D93........................................32, 34, 182
D95.......................................................72
D96 ................................................62, 63
D97....................................132, 133, 182
D113...................................................170
D115 ..........................................192, 197
D127 .................................Upon Request
D128 .................................Upon Request
D130 ................................90-91, 99, 131
D139...................................................176
D153...................................................192
D156.........................................44, 46-47
D189.........................................56-57, 60
D215...................................................192
D216.....................................................55
D217 ...................................24-26, 28-29
D233.....................................................55
D240.....................................................76
D244 ................................16-17, 72, 176
D270 ...............................................66-67
D285 ...............................................56-57
D287 ...............................................48-49
D297...................................................192
D301...................................................192
D322...................................................192
D323 ................................50, 92-94, 182
D369...................................................192
D370.....................................................72
D381 ...............................................86-87
D402...................................................192
D422...................................................192
D445.......................2-13, 18-19, 22, 182
D446 .................................................8-13
D447.....................................................55
D453...................................................192
D473.....................................................61
D482.....................................................63
D483 .................................Upon Request
D524.....................................................59
D525 ...............................................80-84
D555...................................................192
D565...................................................192
D566...................................................150
D609...................................................197
Standard
Page No.
D611.......................................42-43, 182
D612...................................................192
D613 ..........................................102, 182
D664.....................................................75
D665.....................................98, 128-129
D721...................................................179
D789...................................................192
D848...................................................193
D849...................................................197
D850 ...............................................55-57
D854...................................................193
D873 ...............................................80-84
D874.....................................................63
D877...................................................134
D888...................................................193
D889...................................................193
D891...................................................193
D892...........................................108-110
D893.....................................................62
D897...................................................197
D914...................................................193
D937.........................................24-27, 29
D941...................................................193
D942.....................................77, 152-153
D943...........................................119-122
D971 .................................Upon Request
D972...................................................148
D1015........................................182, 193
D1016 ................................................193
D1018 ................................................193
D1065 ................................................193
D1072 ................................................193
D1078.............................................55-57
D1085 ...............................Upon Request
D1091 ................................................193
D1092 ................................................157
D1093 ................................................193
D1120 ................................................193
D1142...................................................88
D1160.............................................53-54
D1168 ................................................193
D1173 ................................................193
D1177 ............................................68, 97
D1209.............................................46-47
D1217 ................................................193
D1218...................................................73
D1250...................................................64
D1261 ................................................197
D1263 ................................................160
D1264 ................................................162
D1265.............................................66-67
D1266 ................................................193
D1267.............................................92-94
D1275 ................................................197
D1298.............................................48-50
D1310...................................................37
D1319........................................104, 182
D1321.......................................24-26, 29
D1322...................................................95
D1347 ................................................193
D1384 ................................................197
Standard
Page No.
D1394 ................................................193
D1401 ................................................111
D1402 ................................................197
D1403 ................................24-25, 27, 29
D1404 ................................................166
D1465 ................................................177
D1478 ................................................159
D1480 ................................................194
D1481 ................................................194
D1500.............................................45-46
D1505 ................................................194
D1524...................................................45
D1533...................................................51
D1541 ................................................194
D1544 ............................................46, 47
D1552 ...............................Upon Request
D1559 ...............................Upon Request
D1607 ................................................194
D1638 ................................................194
D1655...................................................97
D1657 ................................................103
D1740 ...............................Upon Request
D1742 ................................................165
D1743 ................................................154
D1744 ................................................182
D1747...................................................73
D1748...................................................65
D1754 ................................................174
D1796...................................................62
D1816 ................................................134
D1831 ..........................................27, 156
D1837 ................................................105
D1838...................................................89
D1839 ................................................194
D1840 ...............................Upon Request
D1925...................................................47
D1949 ................................................194
D1963 ................................................194
D1966 ..........................................62, 194
D1989...................................................76
D2001 ................................................194
D2002 ................................................194
D2003 ................................................194
D2007 ................................................194
D2036 ................................................194
D2068...................................................76
D2111 ................................................194
D2112.........................................114-118
D2155...................................................39
D2158 ................................................105
D2162 ............................18-19, 182, 194
D2170...........................................2, 4-13
D2171 ............................................12, 13
D2184 ................................................195
D2265 ................................................151
D2266................................140, 146, 197
D2272.........................................114-118
D2273...................................................62
D2274.........................................119-122
D2352 ................................................195
D2363 ................................................195
215
Standard
Page No.
D2384...................................................58
D2385 ................................................195
D2386.....................................96-97, 182
D2420 ................................................195
D2440........................................119, 123
D2500 ................................132-133, 182
D2509 ................................................143
D2511 ................................................197
D2532.....................................................7
D2533 ................................................195
D2547...................................................60
D2549 ................................................195
D2569 ................................................195
D2570 ................................................197
D2595 ................................................149
D2596........................................140, 197
D2619........................................195, 197
D2622 ................................................182
D2624 ...............................Upon Request
D2625 ................................................145
D2670 ................................................145
D2688 ................................................197
D2699........................................102, 182
D2700........................................102, 182
D2709...................................................62
D2711 ..........................................62, 112
D2717 ................................................195
D2747...................................................58
D2748 ................................................195
D2780 ................................................195
D2782 ................................................143
D2783........................................140, 197
D2784...................................................58
D2785...................................................58
D2789 ................................................182
D2847 ................................................197
D2872 ................................................175
D2878.........................................148-149
D2879 ................................................195
D2882 ................................................146
D2884.......................................24-25, 29
D2886 ................................................195
D2892 ..........................................54, 195
D2893.........................................119-122
D2896...................................................75
D2910 ................................................195
D2912 ................................................195
D2913 ................................................195
D2914 ................................................195
D2972 ................................................195
D2983.............................................14-15
D3117...................................................94
D3120........................................182, 195
D3143...................................................37
D3174...................................................63
D3227...................................................75
D3230 ..........................................61, 182
D3231 ................................................182
D3233 ................................................145
0-215-218_12c_TestMethods_Layout 1 10/24/12 11:45 AM Page 216
Test Method Standards Index (Continued)
(ASTM) Methods (continued)
Standard
Page No.
D3234 ................................................195
D3235 ................................................179
D3237 ................................................182
D3241 ...............................Upon Request
D3242........................................182, 196
D3246........................................182, 196
D3278...................................................38
D3336 ................................................146
D3340 ................................................182
D3366...................................................68
D3427 ................................................113
D3431 ................................................196
D3505 ................................................196
D3524 ................................................182
D3527 ................................................161
D3603 ..................................98, 128-129
D3605 ................................................182
D3606 ................................................182
D3608 ................................................196
D3610 ................................................182
D3702 ................................................146
D3710 ................................................182
D3712 ................................................196
D3798 ................................................182
D3799 ...............................Upon Request
D3810 ................................................197
D3825 ................................................196
D3828...................................................38
D3831........................................182, 196
D3867 ................................................196
D3904 ................................................196
D3907 ................................................196
D3908 ................................................196
D3945 ................................................196
D3948 ...............................Upon Request
D4006 ................................................196
D4007...................................................62
D4048 ................................................155
D4049 ................................................163
D4052 ..........................................64, 182
D4053 ................................................182
D4057.............................................66-67
D4059 ................................................182
D4110 ................................................182
D4172........................................140, 146
D4180 ................................................196
D4206...................................................38
D4290 ................................................161
D4291 ................................................182
D4294 ................................................182
D4310.........................................119-122
D4327 ................................................182
D4340 ...............................Upon Request
D4377 ................................................182
D4420 ................................................182
D4422...................................................63
D4484 ................................................196
D4486 ................................................196
D4512 ................................................196
Standard
Page No.
D4530 ...............................Upon Request
D4539 ................................................105
D4628 ................................................182
D4629........................................182, 196
D4635 ................................................197
D4636 ................................119, 124-125
D4693 ................................................159
D4737.............................................56-57
D4739...................................................75
D4742.........................................114-118
D4809...................................................76
D4814 ..........................................99, 196
D4815 ................................................182
D4860 ...............................Upon Request
D4871................................119, 196, 197
D4927 ................................................182
D4928 ..........................................51, 182
D4929 ................................................182
D4950.............24-25, 28, 150-151, 154,
...................................1593159, 161-162
D4951 ................................................182
D4953 ................................................182
D5000 ...............................Upon Request
D5001 ................................................145
D5002...................................................64
D5006...................................................73
D5056 ................................................182
D5059 ................................................182
D5134 ................................................182
D5182 ...............................Upon Request
D5183 ................................................140
D5184 ..........................................63, 182
D5186 ................................................182
D5188 ................................................182
D5191 ................................................182
D5236...................................................54
D5304...................................................85
D5307 ...............................................182
D5329.......................................24-26, 29
D5386...................................................47
D5441 ................................................182
D5442 ................................................182
D5443 ................................................182
D5453 ................................................182
D5468...................................................76
D5480 ................................................182
D5482 ................................................182
D5546...................................................62
D5599 ................................................182
D5600 ................................................182
D5619 ................................................146
D5620 ................................................145
D5622 ................................................182
D5623 ...............................................182
D5704 ................................................127
D5769 ................................................182
D5771........................................133, 182
D5772........................................133, 182
D5773........................................133, 182
Standard
Page No.
D5800 ................................................136
D5853.........................................132-133
D5863 ................................................182
D5865...................................................76
D5892 ................................................170
D5901 ..........................................97, 182
D5931...................................................64
D5949 ................................................182
D5950........................................133, 182
D5968 ................................119, 124-125
D5969 ................................................154
D5972 ................................................182
D5985 ................................................182
D5986 ................................................182
D6045.............................................46-47
D6074...........2-13, 36, 45, 48-50, 59-60
.............66-67, 90-91, 99, 111, 131-133
D6079 ................................................141
D6082.........................................108-110
D6084 ................................................170
D6138 ................................................144
D6158....2-13, 36, 48-50, 90-91, 98-99,
...........111, 120-122, 128-129, 131-133
D6160 ................................................182
D6166...................................................47
D6184 ................................................164
D6258 ................................................182
D6277 ................................................182
D6278 ................................................146
D6287 ...............................Upon Request
D6293 ................................................182
D6296 ................................................182
D6304 ..........................................51, 182
D6334 ................................................182
D6352 ................................................182
D6371 ................................100-101, 182
D6378 ................................................182
D6379 ................................................182
D6417 ................................................182
D6443 ................................................182
D6445 ................................................182
D6481 ................................................182
D6521 ................................................173
D6550 ................................................182
D6594 ................................119, 124-125
D6703...................................................52
D7066 ................................................166
D7320 ...............................Upon Request
D7528 ...............................Upon Request
D7548...................................................88
E8 .......................................................197
E28 .....................................................172
E100................................................48-49
E102................................................16-17
E123 .....................................................72
E133 .....................................................55
E308 .....................................................46
E659 .....................................................39
E711 .....................................................76
216
Standard
Page No.
F483 ...................................................197
F484 ...................................................197
F519 ...................................................197
G65.....................................................146
G76.....................................................146
G77.....................................................146
G99 ............................................142, 146
G105...................................................146
G133 .................................Upon Request
P226...................................................170
0-215-218_12c_TestMethods_Layout 1 10/24/12 11:45 AM Page 217
Test Method Standards Index (Continued)
Institute of Petroleum (IP) Standards
Standard
Page No.
IP2 ..................................................42-43
IP4........................................................63
IP13......................................................60
IP14......................................................59
IP15 ............................................132-133
IP16 ................................................96-97
IP32....................................................170
IP34................................................32, 34
IP36................................................33, 36
IP40 ................................................81-84
IP48....................................................126
IP49 ................................................24-26
IP50..........................................24-26, 28
IP53......................................................61
IP55....................................................178
IP57......................................................95
IP58 ...........................................171, 172
IP69 ................................................92-94
IP71 ..................................................2-13
IP74......................................................72
IP75......................................................62
IP77......................................................60
IP80....................................................172
IP121..................................................164
IP123 ..............................................55-57
IP131 ..............................................86-87
IP132..................................................150
IP135....................................98, 128-129
IP138 ..............................................81-84
IP142....................................77, 152-153
IP145....................................................62
IP146..........................................108-110
IP154........................................90-91, 99
IP 156.................................................104
IP158..................................................179
IP160 ..............................................48-49
IP161 ..............................................92-94
IP163....................................................63
IP170 ...........................................32, 182
IP179........................................24-25, 27
IP182....................................................60
IP183..................................................148
Standard
Federal Test Method Standards
Page No.
IP195 ..............................................55-57
IP196....................................................45
IP198..................................................172
IP215..................................................162
IP219..........................................132-133
IP220..................................................144
IP227....................................................99
IP229..........................................114-118
IP235..................................................103
IP239..................................................140
IP240..................................................143
IP241 ................................Upon Request
IP243....................................................58
IP248....................................................60
IP265 ...................................................61
IP267 Method A...................................14
IP267 Method B...................................15
IP280..................................................126
IP291....................................................72
IP300..................................................140
IP303....................................................38
IP304..............................................33, 35
IP306..................................................126
IP307..................................................126
IP309..........................................100-101
IP310........................................24-25, 27
IP313..................................................113
IP319 ............................................2, 4-13
IP326..................................................143
IP335..................................................126
IP359....................................................62
IP376....................................................26
IP386....................................................51
IP387....................................................76
IP419..................................................101
IP421..................................................136
IP438....................................................51
IP441..................................................133
IP444..................................................133
IP445..................................................133
IP446..................................................133
IP516 .................................................170
Page No.
MIL-A-7866 .......................................197
MIL-A-8243 .......................................197
MIL-B-81705 .....................................197
MIL-C-6529 .......................................197
MIL-C-11796 .....................................197
MIL-C-15074 .....................................197
MIL-C-19853A...................................197
MIL-C-16173 .....................................197
MIL-C-22230 .....................................197
MIL-C-23411 .....................................197
MIL-C-25769H...................................197
MIL-C-46113 .....................................197
MIL-C-81309A...................................197
MIL-G-10924SA ................................156
Standard
Page No.
MIL-L-6085........................................197
MIL-L-7808........................................197
MIL-L-7870........................................197
MIL-L-8937........................................197
MIL-L-23398......................................197
MIL-L-23699......................................197
MIL-L-23699B ...................................197
MIL-L-25017C ...................................197
MIL-L-46000......................................197
MIL-L-46010......................................197
MIL-L-B1329 .....................................197
MIL-R-81294.....................................197
MIL-R-25143A...................................197
MIL-S-8660 .......................................197
Page No.
FTM 141-4294.....................................36
FTM 791-101 .......................................44
FTM 791-102 .......................................45
FTM 791-201.....................................132
FTM 791-304..................................16-17
FTM 791-305....................................2-13
FTM 791-311 ...........................24-26, 28
FTM 791-312..................................24-25
FTM 791-313 ...........................24-26, 28
FTM 791-321.....................................164
FTM 791-322.....................................165
FTM 791-334.....................................159
FTM 791-351.....................................148
FTM 791-1001.....................................55
FTM 791-1015.....................................55
FTM 791-1101.....................................35
FTM 791-1102.....................................34
FTM 791-1103.....................................36
FTM 791-1201 ...............................92-94
FTM 791-1402...................................178
FTM 791-1411.....................................96
FTM 791-1421...................................150
FTM 791-2107.....................................95
FTM 791-2503...................................197
FTM 791-2504...........................127, 197
FTM 791-3001.....................................72
FTM 791-3002.....................................61
FTM 791-3007...................................197
FTM 791-3201...................................111
FTM 791-3211 ...........................108-110
FTM 791-3213 ...........................108-110
FTM 791-3252...................................162
FTM 791-3302 ...............................86-87
FTM 791-3352 ...............................81-84
FTM 791-3354 ...............................81-84
FTM 791-3451...................................130
Standard
Page No.
FTM 791-3452...................................131
FTM 791-3453 ...........................152-153
FTM 791-3454...................................160
FTM 791-3462...........................135, 197
FTM 791-3601 ...............................42-43
FTM 791-3805...................................197
FTM 791-3810...................................197
FTM 791-3814...................................197
FTM 791-4001...................................197
FTM 791-4011 ............98, 128-129, 197
FTM 791-4012...................................154
FTM 791-5001.....................................60
FTM 791-5002.....................................59
FTM 791-5304...................................197
FTM 791-5305...................................197
FTM 791-5306...................................197
FTM 791-5307 ..........119, 124-125, 197
FTM 791-5308 ..........119, 124-125, 197
FTM 791-5309...........................155, 197
FTM 791-5310.............................65, 197
FTM 791-5311...................................197
FTM 791-5312...................................197
FTM 791-5314...................................197
FTM 791-5315...................128-129, 197
FTM 791-5321...........................130, 197
FTM 791-5322...................................197
FTM 791-5323...................................197
FTM 791-5324...................................197
FTM 791-5325.................90-91, 99, 197
FTM 791-5329...................................197
FTM 791-5331...................................197
FTM 791-5431...................................179
FTM 791-6503...................................197
FTM 791-7001...................................197
FTM 791C-3807.1 .............................145
FTM 791C-3812.1 .............................145
American Association of State Highway and Transportation
Officials (AASHTO) Standards
Standard
Military Standards
Standard
Standard
Page No.
AASHTO-R28.....................................173
AASHTO-T47 .....................................174
AASHTO-T48........................................36
AASHTO-T50 .....................................176
AASHTO-T51 .....................................170
AASHTO-T53 .....................................172
AASHTO-T55........................................72
Standard
Page No.
AASHTO-T59 ...............................72, 176
AASHTO-T72..................................16-17
AASHTO-T73-811................................34
AASHTO-T179 ...................................174
AASHTO-T240 ...................................175
AASHTO-T245..................Upon Request
AASHTO-T301 ...................................170
American Petroleum Institute (API) Standards
Standard
Page No.
API 2542........................................62, 63
API 2548 ..............................................62
API MPMS Chapter 9.1
48-49
217
Standard
Page No.
API MPMS Chapter 10.4...............62, 63
API MPMS Chapter 10.5.....................72
API MPMS Chapter 10.9.....................51
0-215-218_12c_TestMethods_Layout 1 10/24/12 11:45 AM Page 218
Test Method Standards Index (Continued)
ISO International Standards
Standard
Page No.
ISO 1523..............................................32
ISO 1928..............................................76
ISO 2049 ........................................45-46
ISO 2083..............................................60
ISO 2137 ........................................24-28
ISO 2160..................................90-91, 99
ISO 2176............................................150
ISO 2592........................................33, 36
ISO 2719........................................32, 34
ISO 2908............................................179
ISO 2977 ........................................42-43
ISO 3007 ........................................92-94
ISO 3013 ........................................96-97
ISO 3014..............................................95
ISO 3015 ....................................132-133
ISO 3016 ....................................132-133
ISO 3104...........................................2-13
ISO 3405 ........................................55-57
ISO 3675 ........................................48-49
ISO 3679..............................................38
ISO 3680..............................................38
ISO 3733..............................................72
ISO 3734..............................................62
ISO 3735..............................................61
ISO 3841............................................178
ISO 3987..............................................63
ISO 3993............................................103
AFNOR Standards
Standard
Page No.
ISO 4256 ........................................92-94
ISO 4260..............................................58
ISO 4262..............................................59
ISO 4263 ....................................120-122
ISO 4625............................................171
ISO 4630 ........................................46-47
ISO 6245..............................................63
ISO 6246 ........................................86-87
ISO 6251..............................................89
ISO 6271 ........................................46-47
ISO 6614............................................111
ISO 6615..............................................60
ISO 6616 ........................................53-54
ISO 7120..............................98, 128-129
ISO 7536 ........................................80-84
ISO 9038..............................................38
ISO 9120............................................113
ISO 9262 ........................................14-15
ISO 10101-3 ........................................51
ISO 10337............................................51
ISO 11007..........................................144
ISO 12156..........................................141
ISO 12205..................................120-122
ISO 12937............................................51
ISO 13736............................................32
ISO 13757..........................................105
ISO 17025 ..........................18-19, 48-49
Deutsche Norm (DIN) Standards
Standard
Page No.
DIN 5033..............................................47
DIN 6162 ........................................46-47
DIN 6174..............................................47
DIN 51352............................................63
DIN 51355..................................128-129
DIN 51362 ........................Upon Request
DIN 51376............................................36
DIN 51381..........................................113
DIN 51394 .........................119, 124-125
DIN 51406............................................95
DIN 51411............................................44
DIN 51421............................................96
DIN 51428..........................................100
DIN 51550 ........................................2-13
DIN 51551............................................60
DIN 51566..................................108-110
DIN 51570..........................................178
DIN 51571..........................................179
DIN 51572..........................................179
DIN 51575............................................63
DIN 51579......................................24-26
DIN 51580................................24-25, 27
DIN 51581..........................................136
DIN 51585............................98, 128-129
DIN 51586..................................119-122
DIN 51587..................................119-122
Standard
Page No.
DIN 51597..................................132-133
DIN 51599..........................................111
DIN 51616......................................92-94
DIN 51751......................................55-57
DIN 51754......................................92-94
DIN 51757................................48-49, 64
DIN 51758............................................34
DIN 51759................................90-91, 99
DIN 51775......................................42-43
DIN 51780......................................81-84
DIN 51784......................................86-87
DIN 51789............................................61
DIN 51793............................................62
DIN 51799......................................81-84
DIN 51801..........................................150
DIN 51802..........................................144
DIN 51804......................................24-28
DIN 51806..........................................146
DIN 51808..................................152-153
DIN 51817..........................................164
DIN 51900............................................76
DIN 52010............................................26
DIN 52011..........................................171
DIN 52013..........................................170
DIN EN 41 ............................................58
DIN EN 22719......................................32
Standard
Page No.
NF E 48-614.......................................113
NF M 07-002 ..................................55-57
NF M 07-003............................44, 46-47
NF M 07-004 ..................................86-87
NF M 07-007........................................93
NF M 07-010........................................61
NF M 07-011........................................32
NF M 07-012 ..................................81-84
NF M 07-013 ..................................81-84
NF M 07-014........................................60
NF M 07-015 ..................................90-91
NF M 07-019 .................................32, 34
NF M 07-020........................................62
NF M 07-021 ..................................42-43
NF M 07-023........................................60
NF M 07-024......................................104
NF M 07-028........................................95
NF M 07-045........................................63
NF M 07-047..............................120-122
NF M 07-048........................................96
NF M 41-008......................................103
NF M 41-010........................................93
Standard
Page No.
NF T 60-100 .....................................2-13
NF T 60-102.......................................150
NF T 60-104 ...................................46-47
NF T 60-105.......................................132
NF T 60-113.........................................72
NF T 60-114.......................................178
NF T 60-116.........................................60
NF T 60-117.........................................59
NF T 60-119 ...................................24-25
NF T 60-123 ...................................24-25
NF T 60-125.......................................111
NF T 60-129 ...............................108-110
NF T 60-132 ...................................24-25
NF T 60-135.......................................144
NF T 60-142.........................................58
NF T 60-150 ...............................120-122
NF T 60-151.........................98, 128-129
NF T 66-004 ...................................24-25
NF T 66-006.......................................170
NF T 66-008 ..............................171, 172
NF T 66-009.........................................32
Miscellaneous Standards
Standard
Page No.
AACC 58-14....................................24-25
ANS A37.11 .......................................170
ANS 37.2............................................176
ANS Z-11.25 ........................................60
ANS Z-11.6 ..........................................36
AOCS Cc13e.........................................47
AOCS Cc 16-60 ..............................24-25
AOCS CD 12-57 .........................120-122
BP Appendix 5-Method 6....................69
BS 1016 ...............................................76
BS 2000 .............................................174
BS 60814 .............................................51
BS EN 60156 .....................................134
CEC-L-18A ...........................................14
CEC-L-18A-30......................................15
CEI EN 60156 ....................................134
DOT CFR 49-173.115..........................38
EN 116 ...............................................101
EN 13398 ...........................................170
EN 1427 .............................................171
EN 1557 ...............................................47
EPA Method 413.2.............................166
EPA Method 418.1.............................166
Federal Specification SS-R-406C......170
FSPT DT-28-65..............................90, 99
GLP.......................................................69
GPA 2140.............58, 67, 88, 89, 92-94,
103, 105
IATA ......................................................38
IEC 156...............................................134
218
Standard
Page No.
IEC 17025...........................18-19, 48-49
IHC BT-10...................................124-125
JIS K2254 ............................................53
JIS K22541.....................................56-57
JIS K2265 ............................................32
JIS K2207 ..........................................170
JIS K2580 ............................................46
NACE TM01-72....................98, 128-129
NBS MONOGRAPH 150......................74
NF EN 1427........................................171
Ph EUR.................................................47
SIS 155130........................................144
Specification E145,Type 1B...............174
STP 512A...........................................127
TAPPI T652........................................177
UOT ....................................................119
USDA Method 51 (BUL 12-16).........170
USP Ch 631 .........................................47
USP Ch 1061 .......................................47
US Steel Method................................158
VDE 0370 Pt. 5..................................134
0-219-220_12d_StandardSpecs_Layout 1 10/24/12 11:46 AM Page 219
Standard Specifications for Petroleum Products
The following test methods are referenced in published specifications for
petroleum products. For a complete listing of available Koehler testing equipment
for each product type, please refer to the applicable catalog sections.
Product Type
Test Method
Page No.
Product Type
Fuels
Diesel Fuels
Automotive Gasolines
Aviation Fuels
Biodiesel Fuels
Burner, Diesel &
Industrial Gas
Turbine Fuels
Anti-Rust Properties.............................................................98
Autoignition Temperature.....................................................39
Color................................................................................44-47
Copper Corrosion............................................................90-91
Density ......................................................................48-50, 64
Distillation........................................................................55-57
Existent Gum by Evaporation .........................................86-87
Flash Point (Tag Closed)................................................33, 35
Kinematic Viscosity...........................................................2-13
Lead Content.........................................................................60
Iron Corrosion .....................................................................88
Octane Analyzer..................................................................102
Oxidation Stability ...........................................................80-84
Oxygenate Detection .........................................Upon Request
Rapid Flash Point Tester.......................................................38
Reid Vapor Pressure.......................................................92-94
Sampling .........................................................................66-67
Silver Corrosion....................................................................99
Sulfur .................................................................Upon Request
Vapor-Liquid Ratio ............................................Upon Request
Vapor Pressure..................................................Upon Request
Water Content (Karl Fischer Titrator)...................................51
Aromatics............................................................................104
Copper Corrosion............................................................90-91
Density.............................................................................48-50
Distillation........................................................................55-57
Electrical Conductivity.......................................Upon Request
Existent Gum by Evaporation .........................................86-87
Flash Point (Tag Closed)................................................33, 35
Freezing Point..................................................................96-97
Kinematic Viscosity...........................................................2-13
Lead Content.........................................................................60
Lubricity, BOCLE.................................................................145
Mercaptan Sulfur..................................................................75
Naphthalene Content.........................................Upon Request
Net Heat of Combustion.......................................................76
Oxidation Stability ...........................................................80-84
Rapid Flash Point Tester.......................................................38
Reid Vapor Pressure.......................................................92-94
Sampling .........................................................................66-67
Saybolt Color ............................................................44, 46-47
Silver Corrosion....................................................................99
Smoke Point .........................................................................95
Sulfur Content ...................................................Upon Request
Thermal Stability ...............................................Upon Request
Total Acidity .......................................................Upon Request
Water Separation...............................................Upon Request
Acid Number.........................................................................75
Ca, K, Mg and Na Content ................................Upon Request
Carbon Residue, % Wt. ......................................56-57, 59-60
Cetane Index....................................................................56-57
Cetane Number .................................................Upon Request
Cloud Point .................................................................132-133
Copper Corrosion............................................................90-91
Distillation Vacuum.........................................................53-54
Flash Point (Pensky-Martens) ......................................32, 34
Free and Total Glycerine....................................Upon Request
Phosphorous Content.......................................Upon Request
Kinematic Viscosity @ 40˚C..............................................2-13
Sulfated Ash..........................................................................63
Sulfur .................................................................Upon Request
Water and Sediment.............................................................62
API Gravity ......................................................................48-50
ASTM Color.....................................................................45-46
Density ......................................................................48-50, 64
Distillation........................................................................55-57
Existent Gum...................................................................86-87
Flash Point (Pensky-Martens) .......................................32, 34
Flash Point (Tag Closed)................................................33, 35
Kinematic Viscosity...........................................................2-13
Oxidation Stability ...........................................................80-84
Pour Point...................................................................132-133
Fuel Oils
Aviation Turbine Fuels
Containing Synthesized
Hydrocarbons
Kerosene
219
Test Method
Page No.
Ramsbottom Carbon Residue .............................................59
Rapid Flash Point Tester.......................................................38
Sampling .........................................................................66-67
API Gravity ......................................................................48-49
Aromaticity..........................................................................104
Ash ........................................................................................63
Cetane Index....................................................................56-57
Cetane Number .................................................Upon Request
Cloud Point .................................................................132-133
Cold Filter Plugging Point...........................................100-101
Copper Corrosion............................................................90-91
Distillation........................................................................55-57
Electrical Conductivity.......................................Upon Request
Flash Point (Pensky-Martens) .......................................32, 34
Kinematic Viscosity...........................................................2-13
Low Temperature Flow Test...............................................105
Lubricity, HFRR...................................................................145
Oxidation Stability ...........................................................80-84
Pour Point...................................................................132-133
Ramsbottom Carbon Residue .............................................59
Rapid Flash Point Tester.......................................................38
Rust Preventing Characteristics.................................128-129
Sulfur .................................................................Upon Request
Water and Sediment.............................................................62
Wax Appearance Point.........................................................94
API Gravity................................................................48-50, 64
Ash ........................................................................................63
ASTM Color.....................................................................45-46
Copper Corrosion............................................................90-91
Distillation........................................................................55-57
Flash Point (Pensky-Martens) .......................................32, 34
Flash Point (Tag Closed)................................................33, 35
Flocculation...........................................................................52
Kinematic Viscosity...........................................................2-13
Oxidation Stability.......................................................119-123
Pour Point...................................................................132-133
Ramsbottom Carbon Residue .............................................59
Rapid Flash Point Tester.......................................................38
Sampling .........................................................................66-67
Sediment Extraction .............................................................61
Sulfur .................................................................Upon Request
Water and Sediment by Centrifuge......................................62
Water Content by Distillation................................................72
Water Content (Karl Fischer Titrator)...................................51
Vacuum Distillation.........................................................53-54
Aromatics............................................................................104
Copper Corrosion............................................................90-91
Density ......................................................................48-49, 64
Distillation........................................................................56-57
Electrical Conductivity.......................................Upon Request
Existent Gum by Evaporation .........................................86-87
Flash Point (Tag Closed)................................................33, 35
Freezing Point..................................................................96-97
Kinematic Viscosity...........................................................2-13
Mercaptan Sulfur..................................................................75
Naphthalene Content.........................................Upon Request
Net Heat of Combustion.......................................................76
Rapid Flash Point Tester.......................................................38
Smoke Point .........................................................................95
Sulfur .................................................................Upon Request
Thermal Stability................................................Upon Stability
Total Acidity .......................................................Upon Request
Water Separation...............................................Upon Request
Copper Corrosion............................................................90-91
Distillation........................................................................55-57
Flash Point (Tag Closed)................................................33, 35
Freezing Point..................................................................96-97
Kinematic Viscosity...........................................................2-13
Mercaptan Sulfur..................................................................75
Rapid Flash Point Tester.......................................................38
Saybolt Color ............................................................44, 46-47
Smoke Point .........................................................................95
Sulfur .................................................................Upon Request
0-219-220_12d_StandardSpecs_Layout 1 10/24/12 11:46 AM Page 220
Standard Specifications for Petroleum Products (Continued)
Product Type
Liquefied Petroleum
Gas (LPG)
Test Method
Page No.
Copper Strip Corrosion ........................................................89
Density................................................................................103
Hydrocarbon Determination by GC ..................Upon Request
Residues in LPG.................................................................105
Sampling .........................................................................66-67
Sulfur Content.......................................................................58
Vapor Pressure ...............................................................92-94
Volatility...............................................................................105
Lubricants
Aircraft Engine
Lubricant
Automatic
Transmission Fluid
Automotive
Engine Oil
Automotive
Lubricating Grease
Gear Oils
Hydraulic and
Metalworking Fluids
API Gravity................................................................48-50, 64
Conradson Carbon Residue.................................................60
Copper Corrosion...............................................................131
Corrosiveness and Oxidation Stability...............119, 124-125
Flash and Fire Points (Cleveland) ..................................33, 36
Foaming Characteristics.............................................108-110
Kinematic Viscosity...........................................................2-13
Oxy Overpressure Method for Fuel Storage Stability..........85
Pour Point...................................................................132-133
Rapid Flash Point Tester.......................................................38
Sampling .........................................................................66-67
Water & Sediment Content by Centrifuge Method .............62
Water Content (Karl Fischer Titrator)...................................51
Wax Appearance Point.........................................................94
Copper Corrosion...............................................................131
Density ......................................................................48-49, 64
Foaming Characteristics.............................................108-110
Rust Preventing Characteristics.................................128-129
API Gravity................................................................48-49, 64
ASTM Color.....................................................................45-47
Conradson Carbon Residue.................................................60
Density.............................................................................48-50
Distillation at Reduced Pressures ..................................53-54
Evaporation Loss by Noack Method..................................136
Flash and Fire Points (Cleveland) ..................................33, 36
Flash and Fire Points (Tag Open).........................................37
Flash Point (Pensky-Martens) .......................................32, 34
Flash Point (Tag Closed)................................................33, 35
Foaming Characteristics.............................................108-110
Kinematic Viscosity...........................................................2-13
Low Temperature Brookfield Viscosity ..........................14-15
Pour Point...................................................................132-133
Ramsbottom Carbon Residue .............................................59
Rapid Flash Point Tester.......................................................38
Saybolt Color ............................................................44, 46-47
Water Content (Karl Fischer Titrator)...................................51
Water Content by Distillation................................................72
Apparent Viscosity..............................................................157
Corrosion Preventive Properties........................................154
Dropping Point............................................................150-151
Evaporation Loss ........................................................148-149
Four-Ball Wear and Extreme Pressure ..............................140
High Temperature Life........................................................161
Leakage Tendencies ...........................................................160
Life Performance................................................................161
Low Temperature Brookfield Viscosity ..........................14-15
Low Temperature Torque...................................................159
Oil Separation .....................................................................165
Oxidation Stability.......................................................152-153
Penetration ......................................................................24-29
Rust Protection.....................................................................65
Water Washout...................................................................162
Air Release Properties........................................................113
Copper Corrosion...............................................................131
Demulsibility Characteristics..............................................112
Foaming Characteristics.............................................108-110
Kinematic Viscosity...........................................................2-13
Oxidation Stability.......................................................120-123
Rust Preventing Characteristics.................................128-129
Saybolt Viscosity.............................................................16-17
Thermal Oxidation Stability................................................127
Water Content (Karl Fischer Titrator)...................................51
Corrosiveness and Oxidation Stability...............119, 124-125
Flash and Fire Points (Cleveland) ..................................33, 36
Four Ball Wear Test ............................................................140
Product Type
Steam Turbine
Lubricating Oils
Turbine Oils and
Synthetic Lubricants
Other Products
Bituminous Materials
(including waxes)
Electrical
Insulating Oils
Solvents
220
Test Method
Page No.
Low Temperature Brookfield Viscosity ..........................14-15
Pour Point...................................................................132-133
Oxidation Stability.......................................................114-118
Rust Prevention Characteristics.................................128-129
Sludge Tendency.........................................................119-122
Specific Gravity.........................................................48-50, 64
Thermal Stability ...............................................Upon Request
Water Separation................................................................111
Air Release Properties........................................................113
ASTM Color.....................................................................45-46
Copper Corrosion...............................................................131
Evaporation Loss by Noack Method..................................136
Flash and Fire Points (Cleveland) ..................................33, 36
Foaming Characteristics.............................................108-110
Kinematic Viscosity...........................................................2-13
Load Carrying Capacity (FZG) ..........................Upon Request
Oxidation Characteristics............................................119-122
Oxidation Stability (RPVOT).......................................114-118
Pour Point...................................................................132-133
Rapid Flash Point Tester.......................................................38
Rust Preventing Characteristics.................................128-129
Sampling .........................................................................66-67
Specific Gravity.........................................................48-50, 64
Water Content (Karl Fischer Titrator)...................................51
Water Separability ..............................................................111
Air Release Properties........................................................113
Ash ........................................................................................63
Density ......................................................................48-50, 64
Distillation........................................................................55-57
Evaporation Loss by Noack Method..................................136
Flash Point (Pensky-Martens) .......................................32, 34
Foaming Characteristics.............................................108-110
Kinematic Viscosity...........................................................2-13
Oxidation Stability (RPVOT/TFOUT)...........................114-118
Pour Point...................................................................132-133
Ramsbottom Carbon Residue .............................................59
Rapid Flash Point Tester.......................................................38
Sulfur .................................................................Upon Request
Water and Sediment.............................................................62
Blocking and Picking Point ................................................177
Ductility...............................................................................170
Flash and Fire Points (Cleveland) ..................................33, 36
Flash Point (Tag Open).........................................................37
Float Test.............................................................................176
Melting Point of Waxes......................................................178
Penetration................................................................24-26, 29
Rapid Flash Point Tester.......................................................38
Residue and Oil Distillate by Distillation............................176
Rolling Thin-Film Oven Test...............................................175
Saybolt Viscosity.............................................................16-17
Softening Point...................................................................172
Viscosity by Vacuum Capillary Viscometer .....................2-13
Water Content by Distillation................................................72
Aniline Point ....................................................................42-43
ASTM Color.....................................................................45-46
Flash and Fire Points (Cleveland) ..................................33, 36
Kinematic Viscosity...........................................................2-13
Oxidation Stability (RPVOT/TFOUT)...........................114-118
Pour Point...................................................................132-133
Saybolt Viscosity.............................................................16-17
Visual Examination ...............................................................45
Aniline Point ....................................................................42-43
API Gravity................................................................48-50, 64
ASTM Color.....................................................................45-46
Copper Corrosion............................................................90-91
Distillation........................................................................55-57
Flash Point (Pensky-Martens) .......................................32, 34
Flash Point (Tag Closed) ................................................33, 35
Kinematic Viscosity...........................................................2-13
Rapid Flash Point Tester.......................................................38
Sampling .........................................................................66-67
Saybolt Color ............................................................44, 46-47
Vapor Pressure ...............................................................92-94
Volatility...............................................................................105
Water Content (Karl Fischer Titrator)...................................51
0-221-225_12e_Generalindex_Layout 1 10/24/12 11:49 AM Page 221
General Index
A
Accelerated Aging of Asphalt Binder using a
Pressurized Aging Vessel (PAV)..................................................................173
Accelerated Iron Corrosion Tester (AICT).....................................................88
Acidity (Inorganic) of Petroleum Products ...................................................60
Acidity and Alkalinity in Greases ..............................................Upon Request
AFNOR Standards
See AFNOR Index......................................................................................218
AFT ...................................................................................................................52
Air Jet Erosion Tester ...................................................................................146
American Association of State Highway and Transportation Officials
(AASHTO) Standards
See AASHTO Index....................................................................................217
American Petroleum Institute (API) Standards
See API Index............................................................................................217
Anhydride Purity Bath.....................................................................................68
Aniline Point of Petroleum Products.......................................................42-43
Antirust Properties of Petroleum Products Pipeline Cargoes ....................98
AOCS Penetration Cone .................................................................................27
API Gravity Hydrometers................................................................................48
Apparent Viscosity of Lubricating Grease..................................................157
Aqueous Engine Coolant Solution, Freezing Point of .................................68
Ash Determination..........................................................................................63
Asphaltene Precipitation................................................................................52
Asphalt Institute Viscometers........................................................................13
Asphalts
Please refer to the “Bitumens and Waxes” section .........................169-180
Assessing Distillate Fuel Storage Stability by Oxygen Overpressure.......85
ASTM Copper Strip Corrosion Standards.......................................89-91, 155
ASTM Metric Thermohydrometers................................................................48
ASTM Test Methods
See ASTM Index................................................................................215-216
ASTM Thermometers............................................................................184-191
ATF Lubricity Test Rig (BOCLE) ...................................................................145
Autoignition Temperature of Liquid Chemicals ...........................................39
Automated/Automatic
Air Release Value Apparatus.....................................................................113
Aniline Point.................................................................................................42
Calorimeter ..................................................................................................76
Centrifuge ....................................................................................................62
Cloud and Pour Point................................................................................133
Cold Filter Plugging Point .........................................................................101
Color Measurement ...............................................................................46-47
Density Meter ..............................................................................................64
Dielectric Breakdown Tester......................................................................134
Distillation........................................................................................54, 56-57
Ductility and Elastic Recovery (Semi-Auto) .............................................170
Filter Plugging Tendency Analyzer (FPT)....................................................76
Flash Point..............................................................................................32-33
Flocculation Titrimeter.................................................................................52
Freezing Point..............................................................................................97
Karl Fischer Titrator.....................................................................................51
Low Temperature Filterability Test Analyzer (LTFT) .................................105
Melting Point Range....................................................................................69
Noack, Non-Woods Metal.........................................................................136
Penetration...................................................................................................25
Potentiometric Titrator ................................................................................75
Refractive Index...........................................................................................73
Saybolt Viscosity .........................................................................................16
Smoke Point ...........................................................................Upon Request
Softening Point..........................................................................................171
Automotive Gasoline
See Standard Specifications for Petroleum Products Index ...................219
Aviation Fuels
See Standard Specifications for Petroleum Products Index ...................219
Aviation Turbine Fuels Containing Synthesized Hydrocarbons
See Standard Specifications for Petroleum Products Index ...................219
B
Bacon Bomb Samplers...................................................................................66
Ball-On-Cylinder Lubricity Evaluator (BOCLE)...........................................145
Bath Oil ..............................................................................................................8
Baths
General Purpose ....................................................................................70-71
Penetrometer...............................................................................................29
See individual product/test listings
Bearing Compatibility of Turbine Oils.........................................................131
Bearing and Grease Noise Characteristics ................................................146
Bending Apparatus .......................................................................................172
Benzene, Toluene, and Total Aromatics Standards ..................................182
Biodiesel Fuels
See Standard Specifications for Petroleum Products Index ...................219
Bituminous Materials
Please refer to “Bitumens and Waxes” section................................169-180
Penetration Test (See “Penetration” section) .......................................23-30
Water Content by Distillation ......................................................................72
Blocking and Picking Points of Petroleum Wax ........................................177
Bomb Calorimeter...........................................................................................76
Bomb (Pressure Vessel)...............................................................80, 114, 152
Breaking Point of Bitumen, Fraass Method...............................................172
Brookfield Viscosity Bath..........................................................................14-15
BS/IP/RF U-Tube Opaque Viscometers.........................................................12
BS/IP/MSL Miniature Suspended Level Viscometers.................................13
BS/IP/SL Suspended Level Viscometers......................................................13
BS/IP/SL(S) Suspended Level Viscometers.................................................13
BS/U/M Miniature U-Tube Viscometers........................................................12
BS/U-Tube Transparent Viscometers ............................................................12
Bold Series Rotational Viscometer ........................................................15, 21
Burning Characteristics ..............................................................Upon Request
Burst Disk Assembly .................................................................................81-82
C
Calibration Baths
High temperature and low temperature of liquid-in-glass
thermometers ..............................................................................................74
Calibration Kit, for Penetrometer ............................................................24-25
Calorimeter......................................................................................................76
Capillary Viscometers
Cannon®-Fenske Viscometers...............................................................10-11
Cannon®-Manning Viscometers............................................................12-13
Cannon®-Ubbelohde Viscometers ..............................................................11
Carbon Residue
Conradson ...................................................................................................60
Ramsbottom................................................................................................59
Catalysts
for Lubricating Oil Oxidation Stability Tests .............................................122
for (RPVOT) RBOT....................................................................................117
for TFOUT ..................................................................................................117
Centrifuge
Laboratory.............................................................................................62, 63
Portable........................................................................................................63
Cetane No. Analyzer.....................................................................................102
Chlorides..........................................................................................................58
Chlorine Photometer...................................................................Upon Request
Chromometer, Saybolt ...................................................................................44
Cigre Bath......................................................................................................126
Circulators, Refrigerated..........................................................................70-71
221
0-221-225_12e_Generalindex_Layout 1 10/24/12 11:49 AM Page 222
General Index (Continued)
Cleveland Open Cup Flash Tester ..........................................................33, 36
Cloud Point of Petroleum Oils .............................................................132-133
Coking Bulbs ...................................................................................................59
Coking Index....................................................................................................52
Coking Tendency of Oil.................................................................................135
Cold Cranking Simulator Viscosity Standards .............................................19
Cold Filter Plugging Point of Distillate Fuels.....................................100-101
Color
Automated Colorimeter .........................................................................46-47
ASTM......................................................................................................45-46
of Electrical Insulating Oils ....................................................................45-46
of Gasoline .............................................................................................46-47
of Maleic and Phthalic Anhydrides .............................................................68
Saybolt.............................................................................................44, 46-47
Compactors..................................................................................Upon Request
Conductivity
General Purpose..........................................................................................74
of Aviation and Distillate Fuels ................................................Upon Request
Cones, Penetrometer................................................................................26-27
Conradson Carbon Residue ...........................................................................60
Constant Temperature Baths
See individual product listings
Copper Corrosion from Petroleum Products
(Copper Strip Tarnish Test)..................................................90-91, 131, 155
Copper Strip Corrosion by Liquefied Petroleum (LP) Gases......................89
Core-Type Sampling Thief (Tulsa Oil Thief).................................................67
Corrosion of Aviation Fuels
(Silver Strip Tarnish Test)............................................................................99
Corrosion of Cast Aluminum Alloys in Engine Coolants .........Upon Request
Corrosion of Lead by Lubricating Oils........................................................130
Corrosion Inhibition Properties of Greases................................................144
Corrosion Preventive Properties of Lubricating Greases .........................154
Corrosiveness and Oxidation Stability of Petroleum Oils........119, 124-125
Coulometric Karl Fischer Titrator..................................................................51
Cross-Arm Viscometers .................................................................................12
Crude Oil
Density, Relative Density or API Gravity of....................................48-50, 64
Distillation, Vacuum.....................................................................................54
Salt Content of.............................................................................................61
Sediment in............................................................................................61-63
D
Data Acquisition
for Low Temperature Torque of Lubricating Greases..............................159
for Oxidation Stability of Gasoline and Aviation Fuels...................80, 83-84
for Reid Vapor Pressure of Petroleum Products and LPG........................93
for (RPVOT) RBOT ............................................................................114-115
for TFOUT...........................................................................................114-115
for Tribology Equipment ...........................................................................141
Daylight Lamp.................................................................................................44
Dean and Stark Apparatus .............................................................................72
Deleterious Particles Determination Apparatus........................................166
Demulsibility Characteristics ......................................................................112
Density
of Light Hydrocarbons by Pressure Hydrometer.....................................103
of Petroleum Products....................................................................48-50, 64
Deutsche Norm (DIN) Standards
See DIN Index............................................................................................218
Dew Point ........................................................................................................88
Dielectric Breakdown Voltage of Insulating Liquids .................................134
Diesel Fuels
See Standard Specifications for Petroleum Products Index ...................219
Soot Content in........................................................................Upon Request
Diffuser Stones, for Foaming Characteristics Test....................................110
Digital
Penetrometer...............................................................................................25
Stopwatch......................................................................................................8
Tachometer................................................................................................112
Thermometer .............................................................................59, 149, 177
Distillation
of Petroleum Products ..........................................................................55-57
of Petroleum Products at Reduced Pressure.......................................53-55
Water Content by.........................................................................................72
Draft Shield
for Tag Open Cup Flash Tester....................................................................37
Drop Melting Point......................................................................Upon Request
Dropping Point of Lubricating Greases...............................................150-151
Drum Thief.......................................................................................................67
Dry Abrasion Tester ......................................................................................146
Ductility of Bituminous Materials ...............................................................170
Dynamic Viscosity by Rotational Viscometer ........................................20-21
E
Effect of Heat and Air on Asphaltic Materials (Thin-Film Oven Test)......174
Effect of Heat and Air on a Moving Film of Asphalt
(Rolling Thin Film Oven Test).................................................................175
Elastic Recovery of Bituminous Materials .................................................170
Electrometric Salt Determinator....................................................................61
Emcor Grease Testing Machine ..................................................................144
Estimation of Deleterious Particles in Lubricating Grease ......................166
Evaporation Bath
for Existent Gum in Fuels............................................................................86
for Lubricating Greases and Oils ......................................................148-149
Evaporation Cabinet, for Oil Content of Petroleum...................................179
Evaporation Loss
by NOACK Method ....................................................................................136
of Lubricating Oils and Greases........................................................148-149
Existent Gum in Fuels by Jet Evaporation ..............................................86-87
Extension Rods, for Sample Thief ................................................................66
Extraction Apparatus.................................................................................60-61
Extreme Pressure Lubricants
Demulsibility Characteristics.....................................................................112
Oxidation Stability..............................................................................120-122
F
Federal Test Method Standards
See FTM lndex...........................................................................................217
Filter Stick Assembly....................................................................................179
Fire Point Tester.......................................................................................33, 36
Flash Point Testers
Cleveland Open Cup .............................................................................33, 36
Pensky-Martens....................................................................................32, 34
Rapid Tester (Open and Closed Cup) .........................................................38
Tag Closed Cup.....................................................................................33, 35
Tag Open Cup ..............................................................................................37
Float Test for Bituminous Materials............................................................176
Flocculation Titrimeter...................................................................................52
Fluorescent Indicator Absorption Apparatus..............................................104
Foaming Characteristics of Lubricating Oils......................................108-110
Four Ball Wear and Friction Test ................................................................140
Four Ball EP Test...........................................................................................140
Fraass Method ..............................................................................................172
Freezing Point Apparatus
for Aqueous Engine Coolant Solution ........................................................68
222
0-221-225_12e_Generalindex_Layout 1 10/24/12 11:49 AM Page 223
General Index (Continued)
for Aviation Fuels ...................................................................................96-97
for Distillate Fuels ..................................................................................96-97
for Purity of Styrene ................................................................Upon Request
Friction and Wear Test Equipment ......................................................139-146
Front View Distillation Apparatus .................................................................55
Fuel Dilution Monitoring ............................................................Upon Request
Fuel Oils
See Standard Specifications for Petroleum Products Index ...................219
Fuels
Please refer to the “Fuels” section......................................................79-106
Fuel Storage Stability.....................................................................................85
Furnace............................................................................................................63
Furol Orifice.....................................................................................................17
FZG Tester....................................................................................Upon Request
G
Gas Chromatography..................................................................Upon Request
Gauging Pole...............................................................................Upon Request
General Purpose Baths.............................................................................70-71
Glassware for ASTM Methods .............................................................192-196
See individual product listing
Grease Cutter ..................................................................................................26
Grease in Water and Wastewater by IR .....................................................166
Grease Mobility Test.....................................................................................158
Grease Noise Characteristics......................................................................143
Grease Noise Tester .....................................................................................146
Grease Ventability ........................................................................................167
Grease Workers ..............................................................................................28
H
Half Scale Penetration Equipment................................................................27
See “Penetration” section......................................................................23-30
Heat of Combustion........................................................................................76
Heat Transfer Fluid ...........................................................................................8
Heating- Cooling Tube for Aniline Point Apparatus.....................................42
Heithaus Titrimetry.........................................................................................52
Herschel Emulsifier (Water Separability) ..................................................111
Heterogeneous Propellants Yield Stress of
See “Penetration” section......................................................................23-30
High Temperature
Dropping Point Apparatus ........................................................................151
General Purpose/Utility Baths ...............................................................70-71
Evaporation Loss Tester............................................................................149
Kinematic Viscosity Bath...............................................................................6
Wheel Bearing Grease Tester....................................................................161
High Frequency Reciprocating Rig (HFRR) ...............................................141
High Resolution Digital Microscope, for Four Ball Tester........................140
High Viscosity Standards, for Asphalts and Polymers................................19
High Voltage Insulating Oil Tester ..............................................................134
Horizontal Disc Rust Test .....................................................................128-129
Hot Air Gun for Autoignition Test...................................................................39
Humidity Cabinet ............................................................................................65
Hydrocarbon Types in Liquid Petroleum Products....................................104
Hydrometers and Accessories .................................................................48-50
I
Immersion Viscometer...............................................................Upon Request
Infrared Analyzer (IR)...................................................................................166
Institute of Petroleum (IP) Standards
See IP Standards Index.............................................................................217
Interfacial Tension ......................................................................Upon Request
Insulating Oil Tester .....................................................................................134
ISO International Standards
See ISO Index............................................................................................218
K
Kansas Road Oil Orifices ...............................................................................17
Karl Fischer Titrator........................................................................................51
Kinematic Viscosity.....................................................................................2-13
Viscometers.......................................................................................5, 10-13
L
L-60-1 Performance Test .............................................................................127
Lead Corrosion Apparatus ...........................................................................130
Lead in Gasoline.............................................................................................60
Leakage Tendencies of Automotive Wheel................................................160
Leveling Device
for Tag Open Cup Flash Tester....................................................................37
Life Performance of Automotive Wheel Bearing Greases........................161
Lincoln Ventmeter ........................................................................................167
Liquefied Petroleum (LP) Gases
Copper Strip Corrosion ...............................................................................89
Corrosion Test Cylinders.............................................................................89
Density.......................................................................................................103
Residues in................................................................................................105
Sample Containers ......................................................................................67
Sulfur Content..............................................................................................58
Vapor Pressure of..................................................................................92-94
Volatility of .................................................................................................105
Loss on Heating of Oil and Asphaltic Compounds....................................174
Low Temperature
Brookfield Viscosity Bath.......................................................................14-15
Cloud Point and Pour Point ..............................................................132-133
Cold Filter Plugging Point (CFPP) ....................................................100-101
Filterability by Low Temperature Flow Test (LTFT) ................................105
Freezing Point ........................................................................................96-97
Grease Mobility Tester...............................................................................158
Kinematic Viscosity Bath...............................................................................6
Pressure Viscometer.................................................................................157
Viscosity Standards.....................................................................................19
Low Temperature Torque of Lubricating Greases .....................................159
Lubricating Ability of Greases.....................................................................146
Lubricating Greases
Please refer to the “Lubricating Greases” section .......................... 147-168
Penetration Tests .................................................................................. 23-30
Lubricating Oils
Please refer to the “Lubricating Oils” section...................................107-138
M
Manometer for RVP Test................................................................................94
Marshall Apparatus ....................................................................Upon Request
Master Series Rotational Viscometer...........................................................20
Mechanical and Dynamic Behavior of Greases.........................................146
Mechanical Stability of Greases .................................................................146
Melting Point Apparatus ................................................................................69
Melting Point of Petroleum Wax.................................................................178
Mercaptan Sulfur ............................................................................................75
Metal Test Specimens
See individual product listing
See “Test Specimens” section..................................................................197
Metalworking Fluids
Corrosiveness and Oxidation Stability ..............................................124-125
223
0-221-225_12e_GeneralindexREV_Layout 1 11/1/12 2:15 PM Page 224
General Index (Continued)
Flash and Fire Points (Cleveland).........................................................33, 36
Four Ball Wear Test ...................................................................................140
Oil Separation ....................................................................................164-165
Oxidation Stability..............................................................................114-118
Roll Stability...............................................................................................156
Water Washout Characteristics ................................................................162
Micro-Tribometer ........................................................................Upon Request
Microprocessor Based Penetrometer ...........................................................25
Mineral Oil.........................................................................................................8
Modified Koppers Viscometer.......................................................................13
Muffle/Ashing Furnace ...................................................................................63
Multispecimen Tester...................................................................................146
N
NACE Corrosion Test for Pipeline Products..................................................98
Navy Work Factor Machine..........................................................................130
Needles, Penetrometer..................................................................................26
Noack Evaporation Loss Tester ...................................................................136
Norma Hoffman Pressure Vessel (Bomb)..................................................152
O
Octane Analyzer............................................................................................102
Oil in Water and Wastewater by IR ............................................................166
Oil Comparator................................................................................................45
Oil Content of Petroleum Waxes.................................................................179
Oil Separation-from Lubricating Grease ............................................164-165
Optical Sensors, for Kinematic Viscosity Bath ..............................................5
Orifices, Saybolt .............................................................................................17
Oven Rolling Thin Film Oven Test (RTFO) .................................................175
Overflow Ring..................................................................................................28
Oxidata® Pressure Measurement System
for Oxidation Stability of Gasoline and Aviation Fuels..........................83-84
for Oxidation Stability of Lubricating Greases..................................152-153
for RPVOT (RBOT) and TFOUT Methods ................................114-115, 118
Oxidation Pressure Vessel....................................................80, 114, 152-153
Oxidation Test for Lubricating Oil ...............................................................126
Oxidation Stability
See also “Corrosiveness and Oxidation Stability”............................119-125
of Automotive Gasoline .........................................................................80-84
of Automotive Gear Lubricants.................................................................127
of Aviation Fuels.....................................................................................80-84
of Extreme Pressure Lubricating Oils...............................................119-122
of Foods, Oils, Fats and Biodiesel Fuels.....................................................77
of Gasoline Automotive Engine Oils (TFOUT) ..................................114-118
of Gasoline (Induction Period Method) ................................................80-84
of Inhibited Mineral Insulating Oils...........................................................126
of Inhibited Mineral Insulating Oils
by Rotating Pressure Vessel (Bomb) ...............................................114-118
of Inhibited Mineral Oils ....................................................................119-122
of Inhibited Mineral Turbine Oils...............................................................126
of IP Methods............................................................................................126
of Lubricating Grease ........................................................................152-153
of Mineral Insulating Oils .................................................................123, 126
of Distillate Fuel Oils ..........................................................................119-122
of Steam Turbine Oils by Rotating Pressure Vessel (Bomb)...........114-118
of Straight Mineral Oil ...............................................................................126
Oxy-Hydrogen Burner .....................................................................................58
Oxygen Bomb Calorimeter.............................................................................76
Oxygen Overpressure .....................................................................................85
Oxygenates Standards .................................................................................182
P
Panel Coking Test Apparatus.......................................................................135
Pastes, Penetration of........................................................................24-25, 27
Penetrometers and Accessories..............................................................24-29
Pensky-Martens Closed Cup Flash Testers ...........................................32, 34
Petrolatum, Penetration of .........................................................24-25, 27, 29
Petroleum Colorimeter...................................................................................45
Petroleum Standards/Certified Reference Materials (CRM)....................182
Petroleum Waxes
Please refer to the “Bitumens and Waxes” section
Penetration Test ........................................................................................24-29
pH Meter..........................................................................................................74
Pin and V-Block Test.....................................................................................145
Pin-on-Disc Tester ........................................................................................142
Pour Point of Petroleum Oils ...............................................................132-133
Power Series Rotational Viscometer.....................................................15, 21
Precooling Apparatus...................................................................................105
Pressure Bleeding Test Cell ........................................................................165
Pressure Gauge
for Oxidation Stability of Gasoline and Aviation Fuels ...............................84
for Oxidation Stability of Lubricating Greases .........................................152
for Reid Vapor Pressure..............................................................................92
Pressure Hydrometer Cylinder....................................................................103
Pressure Measurement and Recording Systems
for Reid Vapor Pressure of Petroleum Products and LPG .......................93
for Oxidation Stability of Gasoline and Aviation Fuels...................80, 83-84
for Oxidation Stability of Lubricating Greases..................................152-153
for RPVOT (RBOT) and TFOUT Methods.........................114-115, 117-118
Pressure Recorder
for Oxidation Stability of Gasoline and Aviation Fuels ...............................84
for RPVOT (RBOT) Test ............................................................................117
Pressure Vessel ..............................................................................................85
Pressure Viscometer ....................................................................................157
Programmable Ashing/Muffle Furnace.........................................................63
Purity of Styrene by Freezing Point Method............................ Upon Request
Q
Quarter Scale Penetration Equipment ..........................................................27
See “Penetration” section......................................................................23-30
R
R2F Grease Testing Machine ......................................................................146
ROF Grease Testing Machine......................................................................146
Ramsbottom Carbon Residue........................................................................59
Rapid Flash Tester..........................................................................................38
Reciprocatory Friction Tester ......................................................................141
Refractive Index..............................................................................................73
Refrigerated Baths and Circulators
General Purpose ....................................................................................70-71
See individual product listings
Reichert Tester..............................................................................................146
Reid Vapor Pressure.................................................................................92-94
Relative Density of Petroleum Products ..........................................48-50, 64
Residue and Oil Distillate in Emulsified Asphalts by Distillation ..........176
Residues in Liquid Petroleum (LP) Gases.................................................105
Resistance of Lubricating Grease to Water Spray ....................................163
Resistance to Plastic Flow of Bituminous Mixtures Using
Marshall Apparatus................................................................Upon Request
Ring and Ball Apparatus ......................................................................171-172
Roll Stability of Lubricating Grease............................................................156
Rolling Thin Film Oven Test (RTFOT).........................................................175
Rotating Bomb Oxidation Tests (RPVOT/RBOT).................................114-118
Rust Preventing Characteristics....................................................98, 128-129
Rust Protection by Metal Preservatives .......................................................65
224
0-221-225_12e_GeneralindexREV_Layout 1 11/1/12 2:15 PM Page 225
General Index (Continued)
S
Salt Content
Electrometric Method..................................................................................61
Extraction Method .......................................................................................60
Sample Thiefs............................................................................................66-67
Saybolt Chromometers...................................................................................44
Saybolt Viscosity.......................................................................................16-17
Scratch Tester ...............................................................................................144
Sediment in Crude Oils and Fuel Oils
by Extraction................................................................................................61
by Centrifuge.........................................................................................62, 63
Separatory Funnel ........................................................................................112
Sequence IV Foaming Characteristics Test........................................108-110
Sharp Series Rotational Viscometer ............................................................21
Shear Stability ..............................................................................................146
Sighting Device, for Smoke Point Lamp ......................................................95
Silicone Heat Transfer Fluid ............................................................................8
Silver Corrosion by Aviation Turbine Fuels..................................................99
Slurry Abrasion Tester..................................................................................146
Slurry Erosion Tester ....................................................................................146
Smoke Point of Aviation Fuels ......................................................................95
Softening Point of Bitumen ................................................................171, 172
Solvent Extractables in Petroleum Waxes .................................................179
Soot Levels in Diesel Engine Oils.............................................Upon Request
Spare Parts............................................................................................198-209
Specific Gravity...................................................................................48-50, 64
Stability-Corrosion Test for Non-Aqueous Fire Resistant Fluids ............ 126
Stability of Lubricating Oils (Work Factor).................................................130
Standards
Petroleum Test Standards.........................................................................182
Steam Generator for Existent Gum in Fuels ................................................87
Steam Superheater.........................................................................................87
Stirrer Motor
for Freezing Point Apparatus ......................................................................96
for Pensky-Martens Closed Tester..............................................................34
Stopwatch, Digital ............................................................................................8
Sulfur in Petroleum Products and Liquefied Petroleum (LP) Gases.........58
Sulfur Standards ...........................................................................................182
Tribology ................................................................................................139-146
Measurement and Data Acquisition System............................................141
Turbidimeter ................................................................................Upon Request
Turbine Oils
See Standard Specifications for Petroleum Products Index ...................220
U
U-Tube Aniline Point Apparatus ....................................................................43
Ubbelohde Viscometers.................................................................................11
Universal Micro-Tribometer.......................................................Upon Request
Universal Orifices ...........................................................................................17
Universal Wear Test .....................................................................................146
Unsulfonated Residue of Petroleum Plant Spray Oils ............Upon Request
Utility Heater ...................................................................................................72
V
V2F Grease Testing Machine.......................................................................146
Vacuum Distillation Apparatus ................................................................53-54
Vacuum Manifold............................................................................................12
Vacuum Pump for Viscosity of Asphalts by Vacuum
Capillary Viscometers................................................................................13
Vacuum Regulator ..........................................................................................13
Vane Pump Wear..........................................................................................146
Vapor Identification System.......................................................Upon Request
Vapor Pressure of Petroleum Products and Liquefied
Petroleum (LP) Gases..........................................................................92-94
Ventability of Grease....................................................................................167
Ventmeter......................................................................................................167
Viscometer Cleaning and Drying Apparatus ..................................................9
Viscometer Holders ..........................................................................................8
Viscometers...............................................................................................10-13
See Apparent Viscosity, Brookfield Viscosity, Kinematic Viscosity, Saybolt
Viscosity, Dynamic Viscosity and Thomas Stormer Apparatus
Viscosity .......................................................................................................1-22
Viscosity Standards...................................................................................18-19
Volatility of Liquefied Petroleum (LP) Gases ............................................105
Volumetric Karl Fischer Titration ..................................................................75
T
Table Socket....................................................................................................81
Tag Closed Cup Tester .............................................................................33, 35
Tag Open Cup Flash Tester ............................................................................37
Tank Car Gauging Pole...............................................................Upon Request
Tapping Torque Tester ..................................................................................146
Test Tube Bath.................................................................................................90
Test Bomb Bath ...............................................................................................90
Test Specimens.............................................................................................197
Thermal Oxidation Stability of Automotive Gear Lubricants....................127
Thermal Oxidation Stability of Aviation Turbine Fuels............Upon Request
Thermohydrometers..................................................................................48-49
Thermometers.......................................................................................184-191
Calibration Bath ...........................................................................................74
Digital Thermometer..................................................................59, 149, 177
Thin Film Aniline Point Apparatus ................................................................43
Thin-Film Oven Test .....................................................................................174
Thin Film Oxidation Uptake Test (TFOUT)..........................................114-118
Thin Film Oven Test, Rolling.......................................................................175
Timken Test ...................................................................................................143
Titrator.......................................................................................................51, 75
Titrimeter.........................................................................................................52
Torque Wrench for Leakage Tendencies Test ............................................160
Trace Quantities of Total Sulfur.....................................................................58
Traces of Volatile Chlorides in Butane-Butene Mixtures ............................58
Transfer Dish ...................................................................................................26
W
Water and Sediment Content by Centrifuge Method............................62, 63
Water Baths ...............................................................................................70-71
Water in Petroleum Products
by Centrifuge.........................................................................................62, 63
by Distillation ...............................................................................................72
by Coulometric Karl Fischer Titration .........................................................51
by Volumetric Karl Fischer Titration ...........................................................75
Water Separability of Petroleum Oils and Synthetic Fluids.....................111
Water Spray Apparatus for Lubricating Grease.........................................163
Water Washout Characteristics of Lubricating Greases...........................162
Wax Appearance Point of Distillate Fuels....................................................94
Wax Coating Device .....................................................................................177
Wax Melting Point Apparatus......................................................................178
Waxes
See “Bitumens and Waxes” section .................................................169-180
Penetration Test–See “Penetration” section ..................................24-26, 29
Saybolt Color of ....................................................................................44, 46
Wear Testing Equipment ......................................................................139-146
Weathering Test for LPG..............................................................................105
Weighted Beaker ............................................................................................67
Wet Test Gas Meter ......................................................................................110
Wickbold Combustion Apparatus ..................................................................58
Wicks, for Smoke Point Lamp.......................................................................95
225
0-226-228_13_General_Info_Layout 1 10/24/12 11:50 AM Page 226
General Information
Terms
United Parcel Service (UPS) and Parcel Post Shipments
Terms of payment for domestic shipments are net 30 days for firms with
approved credit. New customers are requested to furnish commercial and
bank references in order to facilitate the establishment of an open account.
Export shipments, except to Canada, must be accompanied by a bank draft,
wire transfer, or irrevocable letter of credit, unless satisfactory credit
arrangements have been made with our Credit Department. Payment
must be in U.S. funds. Visa, Mastercard, American Express, and Discover
are accepted.
If damage occurs to a UPS or parcel post shipment, we can file the claim
on your behalf. Retain the shipping container and contact the local UPS
representative or Post Office to arrange for inspection. Notify us within ten
days to enable us to file the claim.
Minimum Order
Small orders are costly for both you and us. Orders for less than $50.00
($100.00 for export shipments) will, therefore, be subject to minimum billing.
Shipping and Insurance
In the absence of specific shipping instructions from you, we will ship your
order by the safest, most economical method. On domestic shipments
there are no packing or crating charges, except in certain instances where
special packing or marking are requested by you. Ocean freight and certain
air freight export shipments requiring special packaging are subject to
additional charges to cover the costs involved. Shipping terms are
Ex-Works our plant, with title passing at such point. All domestic parcel
post and United Parcel Service (UPS) shipments are insured for safe
delivery unless instructed otherwise. If requested by you, or if considered
necessary by us, export shipments will be insured, but in no instance shall
we be liable for failure to insure unless you specifically instruct us to.
Returned Goods Policy
To return products for credit or replacement, please contact Koehler
Customer Service with your purchase order number, our packing
list/invoice number, the item(s) to be returned and the reason for the return.
You will be issued a Returned Authorization (RA) number, which must
be prominently displayed on the shipping container when you return
the material to our plant. Shipping containers without an RA number
prominently displayed with be returned to the sender. Goods must be
returned freight prepaid. Returns will be subject to a restocking charge, the
application of which will depend upon the circumstances necessitating
the return. Some returns cannot be authorized, including certain products
purchased from outside vendors for the convenience of the customer,
products manufactured on special order, products shipped from the
factory past ninety (90) days, and products which have been used or
modified in such a way that they cannot be returned to stock for future sale.
Export Shipment Claims
If damage or loss occurs to a parcel post or air freight shipment insured by
us, retain the shipping container and contents and notify Koehler Instrument
Company immediately. We can arrange for inspection and file the claim
with the carrier on your behalf. If an ocean freight shipment is damaged in
transit, we can file the claim in the U.S. or you can make the adjustment
through the local agent of the insurance company. If we are to make the
claim, report the loss to the carrier and send us the certificate of insurance
and copies of the bill of lading and commercial invoice to expedite
adjustment. Please note that if you request ‘C & F’ terms or specifically
instruct us not to insure the shipment the responsibility for making any
claim rests with you.
Instructions for Filing Freight Claims
Although the greatest care is exercised in preparing your order for
shipment, occasional damage or shortages are unavoidable. Your Koehler
shipment should be unpacked and inspected the same day it is received. If
the shipment is visibly damaged, driver and receiver should both inspect
the contents for damage. Do not accept a visibly damaged shipment unless
the driver endorses both the carrier’s and consignee’s copies of the
delivery receipt as to the damage. If there is either visible or concealed
damage or shortage, immediately notify the delivering carrier (no later
than 15 days after delivery) and request an inspection. The carrier's
representative will inspect the shipment within 48 hours to substantiate the
amount of damage, and will prepare an inspection report. This report is
signed by both the carrier and the receiver and should be included
with a standard claim form and copies of the bill of lading, paid freight
bill and commercial invoice when you file your claim with the carrier.
The merchandise and shipping container should be retained at your facility
until disposition has been made by the carrier or his representative.
Service
Even the finest made equipment occasionally fails to perform as it should.
When you call us with a service problem, we will act quickly to resolve it for
you. Our Technical Service Department maintains a stock of replacement
parts for most needed repairs to ensure that down time will be minimized
should servicing be required.
Warranty
If within one year from date of receipt, but no longer than 15 months from
date of shipment, Koehler equipment fails to perform properly because of
defects in materials or workmanship, Koehler Instrument Company will
repair or, at its sole discretion, replace the equipment without charge F.O.B.
its plant, provided the equipment has been properly installed, operated
and maintained and Koehler is advised in writing of the malfunction and
authorizes the return of the product to the factory. Koehler Instrument
Company’s sole responsibility and the purchaser’s exclusive remedy for any
claim arising out of the purchase of any product is the repair or replacement
of the product. In no event shall the cost of the purchaser’s remedy exceed
the purchase price, nor shall Koehler Instrument Company be liable for any
special, indirect, incidental, consequential or exemplary damages.
KOEHLER INSTRUMENT COMPANY EXPRESSLY DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED
WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE.
226
0-226-228_13_General_Info_Layout 1 10/24/12 11:50 AM Page 227
Notes
227
0-226-228_13_General_Info_Layout 1 10/24/12 11:50 AM Page 228
Notes
228
0-KoehlerCat2012Covers9_Layout 1 12/10/12 12:22 PM Page 2
Worldwide Support
Providing quality testing instrumentation and technical support
services for research and testing laboratories has been our
specialty since 1925. Meeting your testing needs is the primary
focus of our business, which is why Koehler Instrument
Company is a leading producer and supplier of petroleum,
synfuels and petrochemical instrumentation worldwide.
At Koehler, we pride ourselves in innovation. In a time of
continuous technological advancement and transition we are
constantly implementing new and improved ways to surpass
the needs of an ever-evolving industry.
Koehler products are backed by our staff of technically
knowledgeable, trained specialists who are experienced in
both petroleum products testing and instrument service, which
is carried out either on site or at a Koehler service center.
Koehler Instrument Company
Is Proud To Be An Active ASTM Member
For Over Half A Century
With this catalog, we are pleased to present our comprehensive
line of petroleum laboratory instrumentation, both manual and
automatic, as well as standards and accessories conforming to
the latest ASTM, ISO, IP and related international specifications.
We invite you to look through our extensive product offerings
for instrumentation and services to meet your testing needs, or
contact us for custom solutions for your specialized requirements.
Committed to providing you with full support for your laboratory
testing needs, Koehler Instrument Company is more than just an
instrument manufacturer. We take care of you through the whole
process. We have many satisfied customers worldwide and
continue to build new relationships every day because of our
attention to customer needs. Our goal is to be the best and most
dependable instrument company in the market place. We invite
your comments and input so that we may continue to serve you.
www.koehlerinstrument.com
www.koehlerinstrument.com
BOHEMIA, NEW YORK • HOUSTON, TEXAS
0-KoehlerCat2012Covers9_Layout 1 12/10/12 12:21 PM Page 1
Petroleum Testing Equipment
1595 SYCAMORE AVENUE
BOHEMIA, NEW YORK 11716-1796
1-800-878-9070 (IN U.S. ONLY)
TEL: +1 631 589 3800
FAX: +1 631 589 3815
www.koehlerinstrument.com
Email: sales@koehlerinstrument.com
offices in
BOHEMIA, NEW YORK • HOUSTON, TEXAS
Petroleum Testing Equipment
www.koehlerinstrument.com
BOHEMIA, NEW YORK • HOUSTON, TEXAS
© 2013-2014
Koehler Instrument Company, Inc.
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project