Our Line of Rack Solutions Has Expanded!

Our Line of Rack Solutions Has Expanded!
Our Line of Rack Solutions Has Expanded!
RACK ENCLOSURES
Model
SR12UB
SR12UBFFD
SR18UB
SR24UB
SR24UBFFD
SR25UB
SR25UBEXP
SR25UBKD
SR25UBSD3
SR25UBSP1
SR25UBTAA
SR2000
SR2400
SR42UB
SR42UB1032
SR42UBCL
SR42UBDP
SR42UBDPWD
SR42UBEIS
SR42UBEXP
SR42UBG
SR42UBKD
SR42UBMD
SR42UBMDEXP
SR42UBSD
SR42UBSD1032
SR42UBSP1
SR42UBTAA
SR42UBWD
SR42UBWDSP1
SR42UBWDTAA
SR42UBWDVRT
SR42UBZ4
SR42UW
SR42UWEXP
SR42UWSP1
SR45UB
SR45UBDP
SR45UBDPWD
SR45UBEXP
SR45UBMD
SR45UBSD
SR45UBSP1
SR45UBTAA
SR45UBWD
SR45UBWDSP1
SR45UBWDVRT
SR48UB
SR48UBCL
SR48UBDP
SR48UBDPWD
SR48UBEXP
SR48UBSP1
SR48UBTAA
SR48UBWD
SR48UBWDSP1
Size
12U
12U
18U
24U
24U
25U
25U
25U
25U
25U
25U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
42U
45U
45U
45U
45U
45U
45U
45U
45U
45U
45U
45U
48U
48U
48U
48U
48U
48U
48U
48U
48U
WALL-MOUNT RACK ENCLOSURES
Type
Compact
Compact Industrial, Fan/Filtered Door
Compact
Compact
Compact Industrial, Fan/Filtered Door
Standard-Depth
No Side Panels
Knockdown
Shallow-Depth, 3” Casters
Shock Pallet
TAA-Compliant
Economy
Value Series
Standard-Depth
10-32 Threaded Mounting Holes
Colocation
Deep
Deep and Wide
NEMA 12-Rated
No Side Panels
Acrylic Window
Knockdown
Mid-Depth
Mid-Depth, No Side Panels
Shallow-Depth
Shallow-Depth, 10-32 Threaded Mounting Holes
Shock Pallet
TAA-Compliant
Wide
Wide, Shock Pallet
Wide, TAA-Compliant
Wide, Included SRCABLEVRT3
Seismic-Rated
Standard-Depth, White
No Side Panels, White
Shock Pallet, White
Standard-Depth
Deep
Deep and Wide
No Side Panels
Mid-Depth
Shallow-Depth
Shock Pallet
TAA-Compliant
Wide
Wide, Shock Pallet
Wide, Includes SRCABLEVRT3
Standard-Depth
Colocation
Deep
Deep and Wide
No Side Panels
Shock Pallet
TAA-Compliant
Wide
Wide, Shock Pallet
Go to www.tripplite.com/rack for the latest
specifications and ordering information.
Capacity
1,000 lb
1,000 lb
1,000 lb
1,000 lb
1,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
2,000 lb
2,400 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
Model
SRDVRLB
SRWF2U
SRWF2U36
SRWF4U
SRWF4U36
SRWF5U
SRWF5U36
SRWF6U
SRWF6U36
SRW6U
SRW6UG
Size
5U
2U
2U
4U
4U
5U
5U
6U
6U
6U
6U
SRW6UDP
SRW6UW
SRW6UWG
6U
6U
6U
SRW9U
SRW9UG
9U
9U
SRW9UDP
SRW10US
SRW10USG
9U
10U
10U
SRW12U
SRW12UG
12U
12U
SRW12UDP
SRW12UHD
12U
12U
SRW12U13
SRW12U13G
12U
12U
SRW12US
SRW12USG
12U
12U
SRW12USDP
SRW12USDPG
SRW12USNEMA
12U
12U
12U
SRW12US33
SRW12US33G
SRW15US
SRW15USG
12U
12U
15U
15U
SRW18UHD
18U
SRW18US
SRW18USG
18U
18U
SRW18USDP
SRW18USDPG
SRW18US13
SRW18US13G
18U
18U
18U
18U
SRW21U
SRW21UG
21U
21U
SRW26US
SRW26USG
26U
26U
SRW26USDP
SRW26USDPG
26U
26U
(See next page)
Type
Capacity
Security DVR Lockbox Enclosure
60 lb
Low-Profile, Switch-Depth
150 lb
Low-Profile, Server-Depth
150 lb
Low-Profile, Switch-Depth
150 lb
Low-Profile, Server-Depth
150 lb
Low-Profile, Switch-Depth
150 lb
Low-Profile, Server-Depth
150 lb
Low-Profile, Switch-Depth
150 lb
Low-Profile, Server-Depth
150 lb
Low-Profile, Switch-Depth, No Hinged Back
200 lb
Low-Profile, Switch-Depth, No Hinged Back,
200 lb
Acrylic Window
Low-Profile, Switch-Depth Plus, No Hinged Back
200 lb
Low-Profile, Switch-Depth, No Hinged Back, White
200 lb
Low-Profile, Switch-Depth, No Hinged Back,
200 lb
White, Acrylic Window
Low-Profile, Switch-Depth, No Hinged Back
200 lb
Low-Profile, Switch-Depth, No Hinged Back,
200 lb
Acrylic Window
Low-Profile, Switch-Depth Plus, No Hinged Back
200 lb
Low-Profile, Switch-Depth, Hinged Back
200 lb
Low-Profile, Switch-Depth, Hinged Back,
200 lb
Acrylic Window
Low-Profile, Switch-Depth, No Hinged Back
200 lb
Low-Profile, Switch-Depth, No Hinged Back,
200 lb
Acrylic Window
Low-Profile, Switch-Depth Plus, No Hinged Back
200 lb
Low Profile, Server-Depth, Side-Mount,
500 lb
Heavy-Duty
Low Profile, Patch-Depth, No Hinged Back
200 lb
Low Profile, Patch-Depth, No Hinged Back,
200 lb
Acrylic Window
Low-Profile, Switch-Depth, Hinged Back
200 lb
Low-Profile, Switch-Depth, Hinged Back,
200 lb
Acrylic Window
UPS-Depth, Hinged Back
200 lb
UPS-Depth, Hinged Back, Acrylic Window
200 lb
Low Profile, Switch-Depth, NEMA 12-Rated,
200 lb
Hinged Back
Server-Depth, Hinged Back
250 lb
Server-Depth, Hinged Back, Acrylic Window
250 lb
Low-Profile, Switch-Depth, Hinged Back
200 lb
Low-Profile, Switch-Depth, Hinged Back,
200 lb
Acrylic Window
Low Profile, Server-Depth, Side-Mount,
500 lb
Heavy-Duty
Low-Profile, Switch-Depth, Hinged Back
Low-Profile, Switch-Depth, Hinged Back,
Acrylic Window
UPS-Depth, Hinged Back
UPS-Depth, Hinged Back, Acrylic Window
Low Profile, Patch-Depth, Hinged Back
Low Profile, Patch-Depth, Hinged Back,
Acrylic Window
Low-Profile, Switch-Depth, No Hinged Back
Low-Profile, Switch-Depth, No Hinged Back,
Acrylic Window
250 lb
250 lb
Low-Profile, Switch-Depth, Hinged Back
Low-Profile, Switch-Depth, Hinged Back,
Acrylic Window
UPS-Depth, Hinged Back
UPS-Depth, Hinged Back, Acrylic Window
250 lb
250 lb
250 lb
250 lb
250 lb
250 lb
200 lb
200 lb
250 lb
250 lb
WALL-MOUNT OPEN FRAME RACKS
Model
SRWO8U22
SRWO8U22SD
SRWO8U22MD
SRWO8U22DP
SRWO12US
SRWO12UHD
Size
8-22U
8-22U
8-22U
8-22U
12U
12U
Type
8, 12, or 22U, Low-Profile Switch-Depth
8, 12, or 22U, Ultra Low-Profile Patch-Depth
8, 12, or 22U, Very Low-Profile Patch-Depth
8, 12, or 22U, Low-Profile UPS-Depth
Low-Profile Switch-Depth, Pivoting Frame
Low-Profile Switch-Depth, Heavy-Duty
Capacity
150 lb
150 lb
150 lb
150 lb
150 lb
550 lb
Wall-Mount Depth Designations
• Patch-Depth - Max. installed equipment depth of less than 16 in.
• Switch-Depth - Max. installed equipment depth of 16 - 19.99 in.
• Switch-Depth Plus - Max. installed equipment of 20 - 23.99 in.
• UPS-Depth - Max. installed equipment depth of 24 - 31.99 in.
• Server-Depth - Max. installed equipment depth of 32 in. or more.
OPEN FRAME RACKS
Model
SR2POST
SR2POSTAA
SR2POST12
SR2POST13
SR2POST25
SR4POST
SR4POST13
SR4POST25
SR4POST1224
SR4POSTAA
SR12UBEXPNDKD
SR42UBEXPND
SR42UBEXPNDNR3
SR42UBMDEXPND
SR42BMDEXPNDNR3
SR42UWEXPNDNR3
SR45UBEXPND
SR45UBEXPNDNR3
SR45UBMDEXPND
SR48UBEXPND
SR48UBMDEXPND
SR48UBEXPNDNR3
SR4POST48HD
SR4POST50HD
SR4POST52HD
SR4POST58HD
Size
45U
45U
12U
13U
25U
45U
13U
25U
45U
45U
12U
42U
42U
42U
42U
42U
45U
45U
45U
48U
48U
48U
48U
50U
52U
58U
Type
2-Post Rack
2-Post Rack, TAA-Compliant
2-Post Rack for Desktop Use
2-Post Rack
2-Post Rack
4-Post Rack
4-Post Rack
4-Post Rack
4-Post Rack, 12-24 Threaded Mounting Holes
4-Post Rack, TAA-Compliant
4-Post Rack, No Roof, Knockdown
4-Post Rack, Heavy-Duty
4-Post Rack, Heavy-Duty, No Roof, 3” Casters
4-Post Rack, Heavy-Duty, Mid-Depth
4-Post Rack, Heavy-Duty, Mid-Depth, No Roof, 3” Casters
4-Post Rack, Heavy-Duty, No Roof, 3” Casters, White
4-Post Rack, Heavy-Duty
4-Post Rack, Heavy-Duty, No Roof, 3” Casters
4-Post Rack, Heavy-Duty, Mid-Depth
4-Post Rack, Heavy-Duty
4-Post Rack, Heavy-Duty, Mid-Depth
4-Post Rack, Heavy-Duty, No Roof, 3” Casters
4-Post Rack, Heavy-Duty
4-Post Rack, Heavy-Duty
4-Post Rack, Heavy-Duty
4-Post Rack, Heavy-Duty
Capacity
800 lb
800 lb
110 lb
800 lb
800 lb
1,000 lb
1,000 lb
1,000 lb
1,000 lb
1,000 lb
1,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
3,000 lb
COOLING ACCESSORIES
Model
SR1UBRUSH
SR1UPANEL10
SR1UPANEL50
SR1UPANEL200
SRXUPANEL
SRBRUSHWM
SRCEILINGADAPT
SRFAN3U
SRFANROOF
SRFANWM
SRFILTER
SRGASKET
SRSKIRT
SRSWITCHDUCT
Description
1U Cable Pass-Through Panel with Brush Strip
1U Blanking Panel Kit, 10 Pieces
1U Blanking Panel Kit, 50 Pieces
1U Blanking Panel Kit, 200 Pieces
Blanking Panel Kit, 4 Panels in 4 Sizes: 1U, 2U, 4U and 8U
Brush Strip Plate for Wall-Mount Enclosures
Ceiling Tile Adapter Kit for SRCOOL33K
3U Heat Removal Panel, Three Fans
Roof-Mounted Heat Removal Panel
Fan Kit for Wall-Mount Enclosures
Filter Kit for Rack Enclosures
Airflow Optimization Kit
Rack Enclosure Skirt Kit
Side Airflow Ducting Kit
CABLE MANAGEMENT ACCESSORIES
Model
P350-10N-10
PDUMVROTATEBRKT
SRCABLEDUCT1U
SRCABLEDUCTVRT
SRCABLEDUCT1UHD
SRCABLEDUCT2UHD
SRCABLELADDER
SRCABLERING1U
Description
Hook-and-Loop Cable Ties, Pack of 10
PDU Mounting Brackets to Rotate Outlets to Rear of Rack
1U Horizontal Cable Manager
6 ft. Vertical Cable Manager
1U Horizontal Cable Manager
2U Horizontal Cable Manager
10 ft. x 1 ft. Cable Ladder
1U Horizontal Cable Manager, Flexible Ring
CABLE MANAGEMENT ACCESSORIES (CONTINUED)
Model
SRCABLERING2U
SRCABLERINGVRT
SRCABLETRAY
SRCABLETRAYEXP
SRCABLETRAY1U
SRCABLEVRT3
SRCABLEVRT6
SRCABLEVRT12
SRVRTBAR
SRVRTBAR45
SRVRTBAR48
SRVRTRAIL23
SRLADDERATTACH
Description
2U Horizontal Cable Manager, Flexible Ring
6 ft. Vertical Cable Manager, Flexible Ring
Roof-Mounted Cable Trough
Roof-Mounted Cable Trough, Vertical Expansion
1U Horizontal Cable Management Tray
High-Capacity Vertical Cable Manager, 3” Wide
High-Capacity Vertical Cable Manager, 6” Wide
High-Capacity Vertical Cable Manager, 12” Wide
42U Vertical Cable Management Bars
45U Vertical Cable Management Bars
48U Vertical Cable Management Bars
4 x 23-in. Wide Vertical Rackmount Rails
Connects SRLADDER to a Rack
SECURITY ACCESSORIES
Model
SRCOMBO
SRSWITCH
SR42SIDE
SR42SIDEPT
SR48SIDE
SR48SIDE4PHD
SR50SIDE4PHD
SR52SIDE4PHD
SR58SIDE4PHD
Description
Door Handles with Combination Lock, Pack of 2
Magnetic Door Switch, Pack of 2
Side Panel with Locking Key for SR42UB
Side Panels with Locking Key for SR42UB, Pack of 2
Side Panel with Locking Key for SR48UB
Side Panels with Latches for SR4POST48HD, Pack of 2
Side Panels with Latches for SR4POST50HD, Pack of 2
Side Panels with Latches for SR4POST52HD, Pack of 2
Side Panels with Latches for SR4POST58HD, Pack of 3
RACK SHELVES
Model
SRSHELF2P1U
SRSHELF2P1UTM
SRSHELF2P
SRSHELF2PDP
SRSHELF2PX2
SRSHELF2PTM
SRSHELF4PHD
SRSHELF4PHDTM
SRSHELF4PKYBD
SRSHELF4PSL
SRSHELF4PSLHD
Description
1U Cantilever Fixed Shelf
1U Cantilever Fixed Shelf, Toolless Mount
2U Cantilever Fixed Shelf
2U Cantilever Fixed Shelf, Extended Depth
2U Cantilever Fixed Shelf, 2-Sided
2U Cantilever Fixed Shelf, Toolless Mount
Heavy-Duty Fixed Shelf
Heavy-Duty Fixed Shelf, Toolless Mount
Keyboard Shelf
Standard-Depth Sliding Shelf
Heavy-Duty Sliding Shelf
MOUNTING ACCESSORIES
Model
N060-002
N060-004
2POSTRMKITHD
2POSTRMKITWM
4POSTRAILKIT
4POSTRAILKIT1U
B019-000
PDU4PKIT
SR2319ADAPT
SRBOLTDOWN
SRCAGENUTS
SRCAGENUTS1224
SRCAGENUT5MM
SRCASTER
SRCASTERHDKIT
SREXTENDER
SRCOLOKIT42U
SRCOLOKIT48U
SRHALFRAIL
SRPAGODAROOF
SRPDU2PBRKT
SRGROUND
SRGROUNDPANELBC
SRSCREWS
SRSHELFKBD
SRSTABILIZE
UPSHDEARKIT
Description
2U Hinged Wall-Mount Patch Panel Bracket
4U Hinged Wall-Mount Patch Panel Bracket
Heavy-Duty 2-Post Rackmount Kit for 2U-4U UPS Systems
2-Post Wall-Mount Kit for 2U-4U UPS Systems
4-Post Rack Rail Kit
1U Universal Adjustable Rackmount Shelf Kit
2-Post Rackmount Kit for Consoles/Console KVMs
Rear Support Rail Kit for Select Tripp Lite 1U ATS PDUs
Adapter Kit, Mounts 19 in. Rack Equipment in 23 in. Racks
Bolt-Down Kit
Square Hole Hardware Kit, M6, 50 Count
Square Hole Hardware Kit, 12-24, 50 Count
Square Hole Hardware Kit, M5, 50 Count
Rolling Caster Kit
Heavy-Duty Rolling Caster Kit
Rack Enclosure Extension Frame
Colocation Kit for 42U Rack Enclosures
Colocation Kit for 48U Rack Enclosures
21U Rail Accessory, Half Length of 42U Racks
Drip Resistant Rack Enclosure Roof
Vertical PDU Mounting Kit for 2- & 4-Post Open Frame Racks
0U Grounding Kit
1U ESD Grounding Panel
Threaded Hole Hardware Kit, 12-24, 50 Count
1U Rack-Mount Keyboard with KVM Cable Kit
Anti-Tip Stabilizing Plate
Heavy-Duty Mounting Ear Kit
Go to www.tripplite.com/rack for the latest specifications and ordering information.
1111 W. 35th Street, Chicago, IL 60609 | www.tripplite.com | 773.869.1234
© 2016 Tripp Lite. Tripp Lite has a policy of continuous improvement. Specifications are subject to change without notice.
16-05-307 • 95-3111B
RACK & COOLING SOLUTIONS
SmartRack
™
Premium Rack Enclosures, Wall-Mount
Rack Enclosures, Open Frame Racks,
Cooling Solutions & Accessories
Organize and protect rackmount servers,
storage and network / telecom equipment
quickly and conveniently.
and network/telecom equipment quickly and conveniently • Organize and protect
rackmount servers, storage and network/telecom equipment quickly and conveniently
• Organize and protect rackmount servers, storage and network/telecom equipment
quickly and conveniently • Organize and protect rackmount servers, storage and
Diagram• Organize
2-3and protect
network/telecom equipment quicklyApplication
and conveniently
rackmount servers, storage and network/telecom
equipment
conveniently
Rack Enclosures
quickly and
4–7
• Organize and protect rackmount servers,
storageRack
and Enclosures8–9
network/telecom equipment
Wall-Mount
& Open Frame Racks
quickly and conveniently • Organize and protect rackmount servers, storage and
Frame Racks •
network/telecom equipment quicklyOpen
and conveniently
Organize10and protect
rackmount servers, storage and network/telecom
equipment
and conveniently
Cooling Solutions
quickly11–12
Air storage
Conditioning
11-12 equipment
• Organize and protect rackmount servers,
and network/telecom
Heat Removal 11-12
quickly and conveniently • Organize and protect rackmount servers, storage and
Airflow Management 11-12
network/telecom equipment quickly and conveniently
•
Organize and protect
Rack Accessories 13–15
rackmount servers, storage and network/telecom equipment quickly and conveniently
Cable Management 13
• Organize and protect rackmount servers, storage and network/telecom equipment
Shelves 14
quickly and conveniently • Organize and
protect
Security
& rackmount
Monitoringservers,
14storage and
Mounting
& Power
network/telecom equipment quickly and
conveniently
• Organize15and protect
Power Distribution
and16
rackmount servers, storage and network/telecom
equipmentUnits
quickly
conveniently
• Organize and protect rackmount servers, storage and network/telecom equipment
Tripp Lite Rack & Cooling Solutions
Integrated, vendor-neutral solutions designed for your application
Data Center
A
Network Cabinet/
Back Office
S
K
S
G
N
B
K
G
O
H
P
P
P
P
COOL AIR
U
WARM AIR
F
H
F
F
2
Network Closet/
Server Room
N
O
H
H
T
G
K
D
E
I
H
K
H
J
R
M
D
L
Cold
Aisle
Q
Cold
Aisle
C
Hot
Aisle
G
C
A
SRW12US
B
SR12UB
C
SR42UB
D
SR42UBEXP
E
SR42UBTD
F
SR2POST
G
SRCOOL12K
H
SRFANDOOR
I
SRFAN3U
J
SRFANROOF
K
SR1UPANEL10 / SR1UPANEL50
L
SR1UBRUSH
M
SRSKIRT
N
SRCABLELADDER
O
SRCABLETRAY
P
SRCABLEVRT6 / SRCABLEVRT12
Q
SRCABLEDUCTVRT
R
SRCABLERING2U
S
PDUMH20ATNET
T
PDUMV20HVNET
U
PDUMNV30HV
12U Wall-Mount Rack Enclosure (pp. 8-9)
12U Compact Floor-Mount Rack Enclosure (p. 5)
42U Rack Enclosure (pp. 4-7)
42U Expansion Rack Enclosure (pp. 4-7)
42U Thermal Duct Rack Enclosure (pp. 4-7)
45U 2-Post Open Frame Rack (p. 10)
12,000 BTU Compact Air Conditioning Unit (pp. 11-12)
Heat Removal Door (pp. 11-12)
3U Heat Removal Panel (p. 12)
Heat Removal Roof Panel (p. 12)
1U Blanking Panel Kit (p. 12)
1U Cable Pass-Through Panel (p. 12)
Rack Enclosure Skirt (p. 12)
10 ft. Cable Ladder (p. 13)
Roof-Mounted Cable Trough (p. 13)
High-Capacity Vertical Cable Manager (p. 13)
Duct-Type Vertical Cable Manager (p. 13)
Ring-Type Horizontal Cable Manager (p. 13)
1U Switched PDU with Automatic Transfer Switch (p. 16)
0U (Vertical) Switched PDU (p. 16)
0U (Vertical) Monitored PDU (p. 16)
3
R A C K
E N C L O S U R E S
E N C L O S U R E S
12U, 25U, 42U and 48U sizes
Load rating up to 3,000 lb
Toolless mounting slots for vertical PDUs and cable managers
Perforated doors for massive
front-to-rear airflow
E N C L O S U R E S
R A C K
E N C L O S U R E S
R A C K
E N C L O S U R E S
R A C K
4
R A C K
SmartRack Rack Enclosures
R A C K
E N C L O S U R E S
RACK ENCLOSURES
Standard, Expansion, Compact, Deep, Wide,
Deep & Wide, Colocation, Knockdown, Shock Pallet
and Thermal Duct models
Speed Installation
SmartRack Enclosures ship ready for
Cool Your
Equipment
rapid deployment and roll into place
Thermal Duct Rack Enclosures
on heavy-duty casters. Toolless
(SR42UBTD,
mounting slots speed installation of
SR48UBTD) route warm exhaust
vertical PDUs and cable managers.
air directly to your facility’s HVAC
Adjustable mounting rails include
return air stream. An adjustable
easy-view indexing that eliminates
SR42UBWDTD
and
overhead duct isolates warm air
time-consuming measurements of
Toolless
Mounting Slots
rail depth. Lightweight modular
to prevent it from recirculating.
Natural
convection
removes
doors and side panels provide safe,
heat and keeps equipment cool
convenient service access. Integrated baying tabs facilitate combining
without
enclosures in rows. Seamless compatibility with all standard 19-inch
generating additional heat. For
rack equipment ensures trouble-free configuration.
Rack Enclosures that don’t have
using
electricity
or
direct access to an HVAC return
Support Critical Systems
air duct, the Heat Removal
SmartRack Enclosures support advanced cooling, cable management,
Door (SRFANDOOR) supercharges
power distribution and monitoring features that keep your critical
airflow with four centrifugal fans
servers, storage and network/telecom equipment operating around the
housed in a sealed rear door. The
clock. Perforated doors permit massive front-to-rear airflow that exceeds
maintenance-free
server manufacturer requirements and supports hot‑aisle / cold‑aisle
Conditioning Unit (SRCOOL12K / SRXCOOL12K) cools rooms without
configurations for superior data center cooling efficiency.
access to facility HVAC, provides supplemental cooling for overheated
Compact
Thermal Duct Rack Enclosure
Air
rack enclosures and focuses cold air on equipment hot spots.
(See pp. 11-12 for more information.)
S m a r t R a c k E n c l o s u r e s a c c o m m o d a t e a l l s t a n d a r d 1 9 - i n c h r a c k e q u i p m e n t , r e g a r d l e s s o f v e n d o r.
EMC2
R A C K
E N C L O S U R E S
R A C K
E N C L O S U R E S
R A C K
E N C L O S U R E S
Provide Extra Depth & Width
Ship with Pre-Installed Equipment
SmartRack
Deep
(SR42UBWD)
(SR42UBDP),
and
(SR42UBDPWD)
accommodate
Deep
Rack
deeper
Wide
SmartRack Shock Pallet Rack Enclosures (“SP1” and “SP2” models) ship
Wide
with a special reinforced pallet and loading ramps, allowing you to pre-
Enclosures
install equipment and reship the rack enclosure to the final installation
&
servers,
blade
site. The standard “SP1” pallet supports up to 1,250 lb during shipment,
server chassis, large network switches
including the weight of the rack enclosure and all pre-installed equipment.
and high-density installations while
The heavy-duty “SP2” pallet supports up to 2,000 lb during shipment. (See
M
providing ample space for PDUs, cables
and cable managers without obstructing
on pp. 6-7 for more information.)
Install in Confined Spaces
airflow. Enclosures with extra width have
side channels for accessory mounting,
Some of the most difficult installations involve older buildings that weren’t
cable routing and airflow—ideal for
designed for IT equipment. Cramped rooms, low doorways, narrow halls
network switches that have side-to-side
and steep staircases all make transporting and installing rack enclosures
Deep & Wide Rack Enclosure
airflow and forward-facing ports.
difficult, if not impossible. Knockdown Enclosures (“KD” models) ship
Support Colocation
flat in several subassemblies, allowing convenient transport and quick
SmartRack Colocation Enclosures (SR42UBCL and SR48UBCL) are divided
can assemble a Knockdown Enclosure in 45 minutes or less.
reassembly. The detail work is already finished, so an experienced installer
into secure upper and lower compartments (20U or 23U each) with
SmartRack Compact Rack Enclosures (SR12UB) are perfect for branch-office
separate, lockable doors and side panels. Divided compartments allow
and back-office applications where space is limited. They store up to 12U
you to maintain the physical security of installed equipment for multiple
of equipment in locations where larger enclosures won’t fit, including
tenants within a single enclosure footprint, increasing installation
under desks, tables and counters.
flexibility and profit potential. They can also be used to divide equipment
by security level or workgroup. (See
L
on pp. 6-7 for more information.)
Specifications
Model
SR12UB
SR25UB
SR25UBEXP
SR42UB
SR42UBEXP
SR42UBWD
SR42UBDP
SR42UBDPWD
SR48UB
SR48UBEXP
Rack Spaces
12U
25U
25U
42U
42U
42U
42U
42U
48U
48U
Side Panels
Yes (2)
Yes (2)
No
Yes (4)
No
Yes (4)
Yes (4)
Yes (4)
Yes (4)
No
TIA/EIA-310-D, IEC 60297-3-100, DIN 41494, IP20 Protection Rating, RoHS, UL 60950
Compliance
Load Rating
Mounting Depth
250 lb
3,000 lb Stationary / 2,250 lb Rolling
3 to 32.5 in.
4 to 37 in.(1)
4 to 37 in.
4 to 37 in.
4 to 37 in.(1)
4 to 42 in.
Square (Mounting hardware included.)
Mounting Holes
External Height
27 in.
49 in.
External Width
23.63 in.
23.63 in.
23.63 in.
29.53 in.
23.63 in.
29.53 in.
23.63 in.
External Depth
33.5 in.
43 in.
43 in.(1)
43 in.
47.25 in.
47.25 in.
43 in.(1)
Unit Weight
105 lb 340 lb 315 lb 345 lb 195 lb 78.5 in.
149 lb 281 lb 203 lb 89 in.
309 lb 211 lb Special Application Enclosures (2)
Colocation
—
—
—
SR42UBCL
—
—
—
—
SR48UBCL
—
Knockdown
—
SR25UBKD
SR25UBEXPKD
SR42UBKD
SR42UBEXPKD
—
—
—
SR48UBKD
SR48UBEXPKD
Shock Pallet
—
SR25UBSP1
SR25UBEXPSP1
SR42UBSP1
SR42UBEXPSP1
—
—
—
SR48UBSP1
SR48UBEXPSP1
H.D. Shock Pallet
—
SR25UBSP2
SR25UBEXPSP2
SR42UBSP2
SR42UBEXPSP2
—
—
—
SR48UBSP2
SR48UBEXPSP2
Thermal Duct
—
—
—
SR42UBTD
—
SR42UBWDTD
—
—
SR48UBTD
—
(1) Optional SREXTENDER accessory increases maximum mounting depth and external depth by 8 in. See p. 15 for more information. (2) Special Application Enclosures are similar to models listed at the top of the column, with the
following differences: Colocation Enclosures are divided into two compartments (upper and lower) with separate, lockable doors. Knockdown Enclosures ship disassembled into several sections for easy transport and assembly
in confined spaces. Shock Pallet Enclosures include a reinforced shipping pallet and loading ramps, allowing pre-installation of equipment and reshipment to the final destination. The pallet supports up to 1,250 lb during shipment,
including the combined weight of the enclosure and pre-installed equipment. Heavy-Duty Shock Pallet Enclosures increase the shipping pallet capacity to 2,000 lb. Thermal Duct Enclosures include an overhead duct that routes warm
exhaust air to your facility’s air conditioning return stream, providing superior heat removal and thermal isolation. The adjustable duct increases unit height by 20.5 to 34.5 in. and increases unit weight by 65 lb.
5
Feature Focus
A Adjustable Mounting Rails (4) with Easy-View Depth Index
Front and rear sets of vertical
rails adjust in quarter-inch increments. Adjustment is quick and
convenient—simply unscrew the
rails, slide them to the required
depth and refasten. The easy-view
depth index ensures consistent
Square Mounting Holes
rail placement without requiring
Rack Unit Labeling
time-consuming measurements.
Easy-View Depth Index
Square mounting holes and included hardware support standard 19-inch rack installation.
B Toolless Mounting Rails (2) with Easy-View Depth Index
Adjustable rails include toolless
mounting slots for quick installation
of compatible PDUs and cable
managers. The easy‑view depth index
ensures consistent rail placement
without requiring time-consuming
measurements. Mounting slots are
Toolless Mounting Slot
arranged in a standard pattern
Toolless Mounting Button
compatible with a wide variety of
on Tripp Lite PDU
accessories. Each rail can mount two
vertical PDUs or cable managers side-by-side (four per enclosure).
C Roof Panel (Removable)
Spring-loaded pins allow the roof
panel to be removed and replaced
in seconds. The roof includes cable
access channels and mounting slots
for external cable managers.
D Front Door (Lockable/Removable/Reversible)
The door is perforated for optimal airflow,
exceeding server manufacturer requirements.
The door handle is reversible to preserve
standard orientation if the door is reversed.
E Split Rear Doors (Lockable/Removable)
Split rear doors reduce clearance requirements
for service access. The doors are perforated
for optimal airflow, which exceeds server
manufacturer requirements.
F Modular Side Panels (Lockable/Removable)
Modular side panels are smaller and
lighter than full-length side panels,
enabling easier installation and service
access. Most 42U and 48U models
include four side panels; most 25U
models include two. (“EXP” models do
not include side panels.)
6
G Baying Tabs (2)
Baying tabs allow Rack Enclosures to be combined
securely in rows. The center-to-center width of
standard-width models can be set at 600 mm or
24 inches to match standard data center floor tiles.
600 mm
24 in.
H Heavy-Duty Casters (4) & Levelers (4)
Casters support a rolling load up to
2,250 lb, allowing enclosures to be
pre-configured and rolled to the final
installation location. Levelers support
a stationary load up to 3,000 lb and
adjust to improve enclosure stability.
Casters and levelers are removable.
Caster
Leveler
I Convenient Grounding System
All components are grounded to the
enclosure frame, which includes multiple connections for facility ground.
Front and rear doors include quickrelease ground wires for convenient
configuration.
Quick-Release Ground Wire
J Stabilizing Brackets (2)
You can attach the included stabilizing
brackets at the bottom of the enclosure
frame (inside or outside) to improve
stability. The optional SRBOLTDOWN
kit allows you to bolt the brackets to
the floor. For maximum stability, add
the optional SRSTABILIZE Anti-Tip
Stabilizing Plate Kit. (See p. 15 for
more information.)
Bracket Mounted Outside
Bracket Mounted Inside
K Thermal Duct Enclosures
Lockable,
Reversible
Handle
Thermal Duct Enclosures (SR42UBTD, SR42UBWDTD and SR48UBTD)
include an adjustable overhead duct that routes warm exhaust air
to your facility’s HVAC return air stream, providing superior thermal
isolation and cooling efficiency for hot-aisle / cold-aisle data center
configurations. Natural convection removes heat and keeps equipment
cool without using electricity or generating additional heat.
L Colocation Enclosures
Colocation Enclosures (SR42UBCL and SR48UBCL) are divided into two
compartments (upper and lower) with separate, lockable doors. This
allows you to maintain the physical security of installed equipment
for multiple colocation tenants.
M Shock Pallet Enclosures
Shock Pallet Enclosures (“SP1” and “SP2” models) include a reinforced
shipping pallet and loading ramps, allowing equipment pre-installation
and reshipment. The “SP1” pallet supports up to 1,250 lb during
shipment, including the weight of the enclosure and pre-installed
equipment. The heavy-duty “SP2” pallet supports up to 2,000 lb.
C
F
I
D
E
F
G
K
SR42UBTD
A
L
SR42UBCL
A
M
SR42UBSP1
F
A
F
G
B
H
J
A
H
SR42UB
7
A
L
L
-
M
O
U
N
T
S
O
L
U
T
I
O
N
S
SmartRack Wall-Mount Rack Enclosures & Open Frame Racks
Enclosures from 6U to 26U
Locking doors and side panels
W A L L - M O U N T
S O L U T I O N S
WALL-MOUNT SOLUTIONS W
Adjustable mounting rails
Hinged wall bracket for easy access
to equipment and cabling (most models)
Perforated door, top, bottom and sides
for superior ventilation
Optional heavy-duty rolling casters
W A L L - M O U N T
S O L U T I O N S
W A L L - M O U N T
S O L U T I O N S
Deep Enclosure for standard 1U servers
8
Open Frame Racks from 2U to 22U
also available
Secure Equipment in Minimal Space
Adapt to Diverse Applications
SmartRack Wall-Mount Rack Enclosures are perfect for housing IT
Wall-Mount Rack Enclosures are
equipment in rooms with limited floor space. Adjustable vertical
available in a variety of sizes
mounting rails with square holes accommodate all standard 19‑inch
from 6U to 26U. The optional
rack equipment. Sturdy steel frames are rated up to 250 lb. Perforated
Rolling Caster Kit (SRCASTER)
front door, top, bottom and side panels permit generous airflow to
adapts Enclosures to floor-
keep equipment operating safely. Front door, side panels and hinged
standing applications, allowing
wall bracket lock to secure equipment in general-access areas.
them to roll under desks, tables
Provide Convenient Access
or counters.
Most
Enclosures
include
Wall-Mount Enclosure with Rolling Casters
Accommodate Standard 1U Servers
a sturdy hinge between
The
the cabinet and the wall
Enclosure (SRW12US33) provides
bracket,
the
extra mounting depth for deeper
cabinet to swing away from
equipment cabinets. It’s sized
the wall for easy access to
to fit standard 1U servers
equipment and cabling.*
with ample room for cable
allowing
Top and bottom panels
include channels for cable
Wall-Mount Enclosure with
Hinged Wall Bracket
routing. The front door and
Deep
Wall-Mount
Rack
management and unobstructed
airflow.
Deep Wall-Mount Rack Enclosure
side panels are removable.
Organize Equipment Economically
The innovative Pivoting Wall-Mount Open Frame Rack (SRWO12US)
Wall-Mount Open Frame Racks provide compact and economical
allows you to rotate the equipment mounting frame left or right for
equipment organization for 2-post rack applications. Sturdy steel
convenient service access. You can lock the frame in the closed position
frames are rated up to 150 lb. Model SRWO8U22 adjusts to provide
during normal operation or lock it open while you’re configuring or
8U, 12U or 22U of rack space. Model SRWO12US includes a rotatable
maintaining equipment.
mounting frame for easy access to equipment and cabling.
* SRW6U does not have a hinged wall bracket.
S m a r t R a c k E n c l o s u r e s a c c o m m o d a t e a l l s t a n d a r d 1 9 - i n c h r a c k e q u i p m e n t , r e g a r d l e s s o f v e n d o r.
EMC2
A
Feature Focus
A
E
F
E
F
H
I
H
J
D
A
B
SRW6U
SRW12US
B
F
Adjustable Mounting Rails (4)
Front and rear pairs of vertical rails adjust in one-inch increments.
B
SRWO12US
Top/Bottom Vents (4)
Mounting holes accommodate user-supplied fans for increased airflow.
Secure Front Door
can reverse the door swing by rotating the unit 180° before installation.
G
Heavy-Duty Rolling Casters (Optional)
An optional Rolling Caster Kit (SRCASTER)
G
adapts Wall‑Mount Rack Enclosures to mobile
Hinged Wall Bracket
The wall bracket includes a sturdy hinge that allows the cabinet to swing
away from the wall for convenient rear access to equipment and cabling.
You can reverse the swing direction by rotating the unit 180° before
installation. The wall bracket locks for secure access.
D
C
Vents at the top and bottom help remove warm air and draw in cool air.
The door is perforated for ample airflow and locks for secure access. You
C
D
and
floor-standing
applications,
including
installation under a desk, table or counter.
H
Wall Brackets
Caster
The sturdy A-frame wall brackets allow the mounting frame to pivot.
I
Perforated Side Panels (2)
Rotating Equipment Mounting Frame
Two removable side panels ease installation and service access. The side
You can rotate the mounting frame left or right for easy access to
panels are perforated for ample airflow and lock for secure access.
equipment and cabling. Threaded holes support standard 2-post mounting.
E
J
Cable Ports (2 or 4)
Locking, Adjustable Pivot
Ports allow cable routing through the top and bottom of the cabinet or
Unlock the pivot to rotate the mounting frame, lock it in the standard
hinged wall bracket (if present). Removable covers block unused ports.
position or lock it open 90° (left or right) for service access.
Grounding (Not Shown)
Parts are grounded to the frame, which connects to facility ground.
Specifications
Model
Rack Spaces
Front Door
Hinged Wall Bracket
SRW6U
Mounting Depth
SRW26US
Wall-Mount Open Frame Racks (2-Post Mounting)
N060-002
N060-004
SRWO8U22 SRWO12US
10U
12U
12U
12U
18U
26U
2U
4U
8U, 12U or 22U
12U
Metal
Metal
Plexiglas®
Metal
Metal
Metal
None
None
None
None
Yes (Standard)
Yes (Standard)
Yes (Standard)
Front Hinge
Front Hinge
No
Pivoting Frame
No
Yes (Heavy-Duty) Yes (Heavy-Duty) Yes (Heavy-Duty)
TIA/EIA-310-D, IEC 60297-3-100, DIN 41494, IP20 Protection Rating, RoHS, UL 60950
TIA/EIA-310-D, IEC 60297-3-100, DIN 41494, RoHS, UL 60950
200 lb
200 lb
200 lb
200 lb
250 lb
250 lb
250 lb
17 lb
3 to 16.5 in.
3 to 20.5 in.
3 to 20.5 in.
3 to 20.5 in.
3 to 32.5 in.
3 to 20.5 in.
3 to 20.5 in.
5.5 in.
Square (Mounting hardware included.)
14.5 in.
21.5 in.
24.75 in.
23.63 in.
23.63 in.
23.63 in.
Width
17.5 in.
21.6 in.
21.6 in.
Depth
Weight
SRW18US
6U
Mounting Holes
Height
Wall-Mount Rack Enclosures (4-Post Mounting)
SRW12US
SRW12USG SRW12US33
Metal
Standards
Load Rating*
SRW10US
29 lb
55 lb
60 lb
35 lb
150 lb
150 lb
5.5 in.
18 in.
18 in.
Round (Mounting hardware included.)
25 in.
25 in.
35.75 in.
49.75 in.
3.5 in.
7 in.
18 to 42.5 in.
30.5 in.
23.63 in.
23.63 in.
23.63 in.
23.63 in.
19 in.
19 in.
20 in.
19.75 in.
21.6 in.
33.5 in.
21.6 in.
21.6 in.
6 in.
6 in.
18.25 in.
20.5 in.
60 lb
100 lb
96 lb
125 lb
2.5 lb
5 lb
10 to 14 lb
15 lb
* Requires a stable mounting surface capable of bearing the full weight of the unit and installed equipment. Rolling applications require the optional SRCASTER accessory (not compatible with Wall-Mount Open Frame Racks).
9
R A C K S
O P E N
F R A M E
R A C K S
R A C K S
25U and 45U 2-post racks
13U, 25U, 42U and 45U
4-post racks
Toolless mounting slots
for PDUs and vertical
cable managers
Easy assembly and
self-squaring design
R A C K S
F R A M E
O P E N
F R A M E
Load rating up to 3,000 lb
Organize Equipment Economically
Open frame racks provide economical organization for servers and
network/telecom equipment. Sturdy aluminum (2-post) or steel
(4-post) frames are rated up to 3,000 lb. Compact sections facilitate
assembly in confined spaces, such as network/wiring closets and IDFs
(intermediate distribution frames). Toolless mounting slots make
installation of PDUs and cable managers quick and convenient.
Toolless Mounting Slot
Specifications
O P E N
F R A M E
R A C K S
O P E N
SmartRack Open Frame Racks
O P E N
F R A M E
OPEN FRAME RACKS
R A C K S
Model
SR2POST
SR2POST25
SR42UBEXPND
SR4POST
SR4POST25
SR4POST13
Form Factor
2-Post Rack
2-Post Rack
Heavy-Duty 4-Post Rack
4-Post Rack
4-Post Rack
4-Post Rack
Rack Spaces
45U
25U
42U
45U
25U
13U
F R A M E
O P E N
Unit Height
Round/Threaded (Mounting hardware included.)
84 in.
Unit Weight
49 in.
20.3 in.
Unit Width
Unit Depth
3,000 lb Stationary /
2,250 lb Rolling
800 lb (Stationary)
Load Rating
Mounting Holes
10
TIA/EIA-310-D, IEC 60297-3-100, DIN 41494, RoHS (1)
Standards Compliance
Square (Mounting hardware included.)
78.5 in.
84 in.
23.63 in.
4.8 in. (13.5 in. with base.)
29 lb
1,000 lb Stationary / 1,000 lb Rolling (Requires optional SRCASTER kit.)
23 lb
43 in. (2)
142 lb
49 in.
34.6 to 46.1 in. (Includes base.) (3)
58 lb
47 lb
(1) SR42UBEXPND also complies with UL 60950. (2) Mounting depth is adjustable from 4 to 37 in. (3) Mounting depth is adjustable from 24 to 35.6 in.
S m a r t R a c k E n c l o s u r e s a c c o m m o d a t e a l l s t a n d a r d 1 9 - i n c h r a c k e q u i p m e n t , r e g a r d l e s s o f v e n d o r.
EMC2
28 in.
20.3 in.
43 lb
C O O L I N G
C O O L I N G
S O L U T I O N S
Manage airflow to prevent heat from recirculating and building up inside enclosures
Remove heat from enclosures and rooms
Focus supplemental air conditioning on
overheated enclosures or specific hot spots inside enclosures
Provide supplemental air conditioning for rooms
without access to facility HVAC
S O L U T I O N S
C O O L I N G
S O L U T I O N S
C O O L I N G
S O L U T I O N S
C O O L I N G
S O L U T I O N S
SmartRack Cooling Solutions
C O O L I N G
S O L U T I O N S
COOLING SOLUTIONS
Support hot-aisle / cold-aisle configurations for
superior data center cooling efficiency
Heat Removal
As equipment density and ambient temperature increase, Heat Removal
Solutions keep equipment operating reliably. Thermal Duct Rack Enclosures
Cool Critical Systems
(SR42UBTD, SR42UBWDTD and SR48UBTD) use adjustable overhead ducts
High-density Rack Enclosures generate lots of heat, requiring special
providing superior efficiency and thermal isolation. The Heat Removal Door
measures to keep your critical servers, storage and network/telecom
(SRFANDOOR) replaces the perforated rear doors of SmartRack Enclosures
equipment operating reliably. SmartRack Cooling Solutions encompass
with a sealed door equipped with four high-performance centrifugal fans.
several types of cooling that you can combine and customize to fit
The fans supercharge airflow and direct warm air to overhead ducts that
your application. The first type of cooling is airflow management,
connect to a drop ceiling or HVAC return air stream.
which prevents heat from recirculating and building up inside your Rack
Air Conditioning
Enclosure. The second type of cooling is heat removal, which isolates heat
to route warm exhaust air to your facility’s HVAC return air stream,
and eliminates it from your Rack Enclosure and the room. The third type of
The portable, maintenance-free 12,000 BTU Compact Air Conditioning
cooling is supplemental air conditioning, which focuses cold air wherever
Unit (SRCOOL12K) focuses cold air wherever you need additional cooling
additional cooling capacity is required. All SmartRack Cooling Solutions
capacity, whether it’s a network closet without access to facility HVAC,
support hot-aisle / cold-aisle data center configurations. By leveraging
an overheated rack enclosure or a specific hot spot inside an enclosure.
best practices to increase HVAC efficiency, SmartRack Cooling Solutions
Because condensate is re-evaporated for drip-free operation, you won’t
also reduce your data center’s total cost of ownership.
waste time emptying water collection tanks.
Airflow Management
Hot-Aisle / Cold-Aisle Support
SmartRack Enclosures are designed for front-to-rear airflow. Cool air
SmartRack
flows through the perforated front door and cools your equipment, which
fully support hot-aisle / cold-
exhausts warm air through the perforated rear doors. Airflow Management
aisle configurations, essential
prevents warm air from recirculating and contaminating cool air. The first
for cost-effective data center
step is installing the Enclosure’s side panels. The panels aren’t vented
cooling. A hot-aisle / cold-aisle
because sealed sides promote front-to-rear airflow. Block empty rack
configuration increases cooling
spaces with Blanking Panels (SR1UPANEL10 or SR1UPANEL50) to prevent
efficiency and lowers total cost
heat recirculation. Install the Airflow Optimization Kit (SRGASKET) to
of ownership, reducing energy
seal interior gaps. Cable management is also important: SmartRack Cable
consumption by up to 20%.*
Managers (see p. 13) prevent tangled cables from obstructing airflow.
* Source: TCI Data Centers.
Cooling
Solutions
Hot Aisle
Cold Aisle
Hot Aisle
SmartRack Cooling Solutions Support
Hot-Aisle / Cold-Aisle Configurations
11
COOLING SOLUTIONS
AIR CONDITIONING
Compact Air Conditioning Units
Powerful 12,000 BTU Compact Air Conditioning Units offer plug-and-play setup and maintenance-free operation. They
can cool rooms that don’t have access to facility HVAC, provide supplemental cooling for individual rack enclosures or
focus cool air on equipment hot spots. Condensate is re-evaporated for drip-free operation, so you won’t waste time
emptying water collection tanks. Eco-friendly R410a refrigerant meets worldwide environmental standards.
Specifications
Model
SRCOOL12K
SRXCOOL12K
Description
12,000 BTU, 120V, 60Hz Compact Air Conditioning Unit (Maintenance-free; includes installation kit and interchangeable inserts for louvered or duct-connected output.)
12,000 BTU, 230V, 50Hz Compact Air Conditioning Unit (Maintenance-free; includes installation kit and interchangeable inserts for louvered or duct-connected output.)
HEAT REMOVAL
Heat Removal Door
Thermal Duct Rack Enclosures
SRFANDOOR connects to a standard-width 42U
or 48U SmartRack Enclosure in place of the
rear doors. Four high-performance centrifugal
fans supercharge front-to-rear airflow to
remove heat through overhead ducts, which
connect to a drop ceiling or your facility’s
HVAC return air stream. Digital thermometers
display intake and exhaust temperature.
SR42UBTD, SR42UBWDTD and SR48UBTD include
3U Heat Removal Panels
adjustable overhead ducts that route heat to your
facility’s HVAC return air stream, providing superior
thermal isolation and cooling efficiency without
using electricity or generating heat.
Heat Removal Roof Panels
SRFANROOF and SRXFANROOF remove
warm air with six powerful fans.
SRFAN3U and SRXFAN3U remove
warm air with three powerful fans.
Specifications
Model
SR42UBTD
SR42UBWDTD
SR48UBTD
SRFAN3U
SRXFAN3U
SRFANDOOR
SRFANROOF
SRXFANROOF
Compatibility
Description
42U Thermal Duct Rack Enclosure (Overhead duct provides superior heat removal and thermal isolation.)
42U Wide Thermal Duct Rack Enclosure (Overhead duct provides superior heat removal and thermal isolation.)
48U Thermal Duct Rack Enclosure (Overhead duct provides superior heat removal and thermal isolation.)
3U Heat Removal Panel – 120V (3 fans; up to 210 CFM; 5-15P plug.)
3U Heat Removal Panel – 230V (3 fans; up to 210 CFM; C14 inlet.)
Heat Removal Door (208-240V; up to 3,400 CFM. Includes 4 centrifugal fans, thermometers and duct kit.)
Heat Removal Roof Panel, 120V (6 fans; up to 420 CFM; 5-15P plug; toolless mounting.)
Heat Removal Roof Panel, 230V (6 fans; up to 420 CFM; C14 inlet; toolless mounting.)
AIRFLOW MANAGEMENT
2-Post Open
Frame Racks
Wall-Mount
Enclosures
12/25/42/48U
Enclosures
42U
42U
48U








42/48U
25/42/48U
25/42/48U
1U Blanking Panel Kits
1U Cable Pass-Through Panel
Rack Enclosure Skirt
Blanking panels snap into empty rack spaces,
preventing recirculation of warm air.
SR1UBRUSH includes a dense brush strip
that prevents recirculation of warm air.
SRSKIRT prevents recirculation of warm air
through the bottom of the enclosure.
Specifications
Model
SR1UBRUSH
SR1UPANEL10
SR1UPANEL50
SRGASKET
SRSKIRT
12
4-Post Open
Frame Racks
Compatibility
Description
1U Cable Pass-Through Panel (Brush strip prevents recirculation of warm air.)
1U Blanking Panel Kit (10 pieces; toolless snap-in mounting.)
1U Blanking Panel Kit (50 pieces; toolless snap-in mounting.)
Airflow Optimization Kit (Gasket prevents recirculation of warm air through enclosure side gaps.)
Rack Enclosure Skirt Kit (Brush strip prevents recirculation of warm air at bottom of enclosure.)
2-Post Open
Frame Racks

4-Post Open
Frame Racks



Wall-Mount
Enclosures



12/25/42/48U
Enclosures



25/42/48U
25/42/48U
R A C K
A C C E S S O R I E S
R A C K
A C C E S S O R I E S
R A C K
A C C E S S O R I E S
R A C K
A C C E S S O R I E S
R A C K
A C C E S S O R I E S
SmartRack Premium Rack Accessories
Customize racks for specific applications
and changing IT requirements
R A C K
A C C E S S O R I E S
RACK ACCESSORIES
 Manage
cables for unobstructed airflow
 Monitor
security and environmental conditions
Adapt to Any Application
SmartRack Accessories adapt, enhance and expand SmartRack Enclosures
and Open Frame Racks for a variety of applications and evolving IT
requirements throughout your data center’s operational lifespan.
CABLE MANAGEMENT
1U & 2U Horizontal Cable Managers
Vertical Cable Managers
1U duct-type Horizontal Cable
Managers (SRCABLEDUCT1U) and
1U or 2U ring-type Horizontal
Cable Managers (SRCABLERING1U
or SRCABLERING2U) are available.
Ring-type (SRCABLERINGVRT) and ducttype (SRCABLEDUCTVRT) Vertical Cable
Managers support toolless 0U installation
in SmartRack Enclosures and Open Frame
Racks. You can use them in a single 6 ft.
section or two 3 ft. sections.
Cable Troughs
The roof-mounted Cable Trough
(SRCABLETRAY) provides overhead
cable routing and power/data cable
segregation. The Cable Trough
Expansion Unit (SRCABLETRAYEXP)
provides vertical expansion with
additional cable routing channels.
Cable Ladder
The roof-mounted Cable Ladder
(SRCABLELADDER) allows cable
bundles to span data center aisles
or gaps within rack rows. The Cable
Ladder includes two sections that
combine to form a 10 ft. span. A
single section can span a smaller distance, or sections can be cut to
size. (SRCABLELADDER requires SRCABLETRAY or SRLADDERATTACH.)
High-Capacity Vertical Cable Managers
With double-sided cable channels and
flexible fingers at 1U increments, HighCapacity Vertical Cable Managers organize
and secure large quantities of patch
cables in high-density data centers
and network closets. High-Capacity
Vertical Cable Managers are available
in 6 in. (SRCABLEVRT6) and 12 in.
(SRCABLEVRT12) widths.
Specifications
Model
P350-10N-10
SRCABLEDUCT1U
SRCABLEDUCTVRT
SRCABLERING1U
SRCABLERING2U
SRCABLERINGVRT
SRCABLELADDER
SRLADDERATTACH
SRCABLETRAY
SRCABLETRAYEXP
SRCABLEVRT6
SRCABLEVRT12
High-Capacity Vertical Cable
Managers Mounted on
SR2POST Open Frame Racks
Compatibility
Description
10-Pack of Reusable Hook-and-Loop Cable Ties (10 in. x 5/8 in.)
1U Horizontal Cable Manager (Finger duct with cover.)
6 ft. Vertical Cable Manager (Double finger duct with cover; toolless mounting.)
1U Horizontal Cable Manager (Flexible ring type.)
2U Horizontal Cable Manager (Flexible ring type.)
6 ft. Vertical Cable Manager (Flexible ring type; toolless mounting.)
10 ft. x 1 ft. Cable Ladder (Includes 2 sections; requires SRCABLETRAY or SRLADDERATTACH.)
Connects SRCABLELADDER to a wall or Open Frame Rack.
Roof-Mounted Cable Trough (Provides cable routing and power/data cable segregation.)
Roof-Mounted Cable Trough Expansion Unit (Requires SRCABLETRAY.)
High-Capacity Vertical Cable Manager (6 in. wide; double finger duct with cover; toolless mounting.)
High-Capacity Vertical Cable Manager (12 in. wide; double finger duct with cover; toolless mounting.)
2-Post Open
Frame Racks








4-Post Open
Frame Racks








Wall-Mount
Enclosures


12/25/42/48U
Enclosures


25/42/48U




25/42/48U
25/42/48U
25/42/48U
25/42/48U
45U
42/45U
42/48U
45U
42/45U
42/48U
13
RACK ACCESSORIES
(continued)
SHELVES
A variety of durable and sturdy
Rack Shelves are available,
including fixed and sliding
shelves with capacities up
to 250 lb. Cantilever shelves
support 2-post mounting.
SRSHELF4PHD
SRSHELF2P
SRSHELF4PSL / SRSHELF4PSLHD
Specifications
Model
SRSHELF2P
SRSHELF2P1U
SRSHELF4PHD
SRSHELF4PKYBD
SRSHELF4PSL
SRSHELF4PSLHD
Compatibility
2-Post Open
Frame Racks


Description
2U Cantilever Fixed Shelf (60 lb capacity; 18 in. depth.)
1U Cantilever Fixed Shelf (50 lb capacity; 12 in. depth.)
Heavy-Duty Fixed Shelf (250 lb capacity; 26 in. depth.)
Keyboard Shelf (25 lb capacity; 16 in. depth.)
Standard Sliding Shelf (50 lb capacity; 26 in. depth.)
Heavy-Duty Sliding Shelf (100 lb capacity; 26 in. depth.)
4-Post Open
Frame Racks






Wall-Mount
Enclosures

25/42/48U
Enclosures






SECURITY & MONITORING
Combination Lock Door Handle Kit
Door Switch Kit and Environmental Sensor Module
The Combination Lock Door Handle Kit (SRCOMBO)
includes two replacement handles for the front
and rear doors of SmartRack Enclosures. The threedigit combination lock can be bypassed with the
included key, ensuring that administrators always
have access.
The Door Switch Kit (SRSWITCH) includes two magnetic entry
detection switches for the front and rear doors of SmartRack
Enclosures. The switches require connection to ENVIROSENSE, which
must be connected to SNMPWEBCARD or a Tripp Lite Monitored or
Switched PDU.
SRCOMBO
SRSWITCH
ENVIROSENSE
Specifications
Model
ENVIROSENSE
SNMPWEBCARD
Compatibility
Description
Environmental sensor connects to SNMPWEBCARD or Tripp Lite Monitored/Switched PDU for remote
monitoring of temperature and humidity. Also monitors and controls devices that support contact closure
communications. Can monitor up to 3 additional sensors.
2-Post Open
Frame Racks
4-Post Open
Frame Racks
Wall-Mount
Enclosures
12/25/42/48U
Enclosures





RELAYIOCARD
Adds programmable contact closure interface to compatible UPS systems. (6 outputs and 1 input.)



SNMPWEBCARD
Adds network interface to UPS systems for remote monitoring and control via SNMP, Web or telnet.



SRCOMBO
Combination Lock Door Handle Kit (Includes 2 handles with bypass key for front and rear doors.)
SRSWITCH
Magnetic Door Switch Kit (2-pack for front and rear doors. Requires ENVIROSENSE.)


B020-008-17
1U Rack Console KVM with 17 in. LCD and 8-Port KVM (PS/2 or USB. Requires cable kits.)
Add B019-000

SRW12US33

B020-008-17-IP
1U Rack Console KVM with 17 in. LCD, 8-Port KVM and IP Access (PS/2 or USB. Requires cable kits.)
Add B019-000

SRW12US33

B020-U08-19-K
1U Rack Console KVM with 19 in. LCD and 8-Port KVM (PS/2 or USB. Includes 8 cable kits.)
Add B019-000

SRW12US33

B020-016-17
1U Rack Console KVM with 17 in. LCD and 16-Port KVM (PS/2 or USB. Requires cable kits.)
Add B019-000

SRW12US33

B020-016-17-IP
1U Rack Console KVM with 17 in. LCD, 16-Port KVM and IP Access (PS/2 or USB. Requires cable kits.)
Add B019-000

SRW12US33

B020-U16-19-K
1U Rack Console KVM with 19 in. LCD and 16-Port KVM (PS/2 or USB. Includes 8 cable kits.)
Add B019-000

SRW12US33

B021-000-17
1U Rack Console with 17 in. LCD (PS/2 or USB. Includes PS/2 cable kit.)
Add B019-000

SRW12US33

B021-000-19
1U Rack Console with 19 in. LCD (PS/2 or USB. Includes cable kits.)
Add B019-000

SRW12US33

Go to www.tripplite.com for more information about Tripp Lite’s full line of KVM Switches and IP Console Servers, including an interactive selector guide.
S m a r t R a c k E n c l o s u r e s a c c o m m o d a t e a l l s t a n d a r d 1 9 - i n c h r a c k e q u i p m e n t , r e g a r d l e s s o f v e n d o r.
14
EMC2

25/42/48U
RACK ACCESSORIES
(continued)
MOUNTING & POWER
Rack Enclosure Extension Frame
Anti-Tip Stabilizing Plate Kit
Applications like colocation and server farms
often experience rapid
growth, requiring you
to install deeper server
chassis that pack more
processing power into
each rack. Tripp Lite’s
Rack Enclosure Extension Frame (SREXTENDER)
increases mounting depth
by 8 inches without
requiring you to replace
your rack enclosures or
reinstall your equipment.
Standard-width 42U and
48U SmartRack Enclosures
can be retrofitted at any
time, allowing them to
grow as your needs grow.
The Anti-Tip Stabilizing Plate
Kit (SRSTABILIZE) provides
an extra measure of stability
for stand-alone enclosures.
The kit includes front and rear
stabilizing plates. Add the BoltDown Kit (SRBOLTDOWN) to
secure the stabilizing plates to
the facility floor.
SRSTABILIZE
Power Distribution Units (PDUs)
SREXTENDER retrofits 42U and 48U SmartRack
Enclosures to increase mounting depth by 8 inches.
Tripp Lite’s Network-Grade PDUs
distribute power from a UPS
system, generator or wall outlet
to multiple devices. Tripp Lite
makes PDUs with features to
match any application. Vertical
models include toolless mounting buttons for convenient 0U
installation in SmartRack Enclosures and Open Frame Racks.
Select models have digital load
meters and a network interface
that supports remote monitoring and control via SNMP, Web
or telnet. (See p. 16 for more
information.)
Toolless installation of a Tripp Lite PDU—
simply insert the mounting buttons into
the mounting slots and slide downward.
Specifications
Compatibility
2-Post Open
Frame Racks
Model
Description
2POSTRMKITHD
Heavy-Duty 2-Post Mounting Kit (For 3U and 4U UPS systems, battery packs and transformers.)
2POSTRMKITWM 2-Post Mounting Kit (For 2U UPS systems, battery packs and transformers.)
4-Post Open
Frame Racks
Wall-Mount
Enclosures
12/25/42/48U
Enclosures





4POSTRAILKIT
4-Post Rack Rail Kit (Adjustable depth; supports rack equipment cabinets up to 250 lb.)
B019-000
2-Post Console Mounting Kit (For B020-, B021-, B040- and B070-Series Rack Consoles and Console KVMs.)

SRBOLTDOWN
Bolt-Down Kit (Secures included stabilizing brackets or optional stabilizing plates to facility floor.)

SRCAGENUTS
Square-Hole Hardware Kit (Includes 50 cage nuts, screws and washers.)


SRCASTER
Rolling Caster Kit (4 heavy-duty casters. Included with 12/25/42/48U enclosures and SR42UBEXPND.)


SREXTENDER
Rack Enclosure Extension Frame (Increases depth of 42/48U standard-width enclosures by 8 in.)
SRGROUND
0U Grounding Kit (75.5 in. copper bus bar. Includes grounding lug to connect to facility ground and 21
grounding wires to connect to equipment. Supports toolless vertical mounting.)
SRSCREWS
Threaded-Hole Hardware Kit (Includes 50 #12-24 screws and washers.)
SRSTABILIZE
Anti-Tip Stabilizing Plate Kit (Increases stability for stand-alone enclosures.)
SUDC208V42P
42-Pole Power Distribution Center (Breaker panel in 42U enclosure. 3-phase (208V) input. Single-phase
(120V or 208V) and/or 3-phase (208V) output. Requires output breakers and cord sets, sold separately.)




UPSHDEARKIT
Heavy-Duty Mounting Ears (Support 2U cabinets up to 65 lb from two vertical rails without rear support.)








42/48U
45U
42/45U
42/48U
SR42UBEXPND


See p. 16 for more information about Tripp Lite PDUs. Go to www.tripplite.com for more information about Tripp Lite’s full line of UPS Systems, including an interactive UPS selector guide.
S m a r t R a c k E n c l o s u r e s a c c o m m o d a t e a l l s t a n d a r d 1 9 - i n c h r a c k e q u i p m e n t , r e g a r d l e s s o f v e n d o r.
EMC2
15
D I S T R I B U T I O N
P O W E R
U N I T S
P
O
W
E
R
D
I
S
T
R
I
B
U
T
I
O
N
U
N
I
Network-Grade Rack PDUs
Multi-outlet power distribution from UPS system, generator or wall outlet
Single-phase or 3-phase input
Digital load meters, network interface and automatic transfer switch available
Flexible mounting options, including
toolless mounting
Provide Flexible Mounting Options
Manage Power Remotely
Vertical Tripp Lite PDUs include toolless mounting buttons for quick
Monitored and Switched PDUs include a network interface that enables
and easy 0U installation in SmartRack Enclosures and Open Frame
remote load monitoring, remote condition reporting and centralized
Racks. Simply insert the toolless mounting buttons into the toolless
management via SNMP, Web or telnet. Switched PDUs also provide
mounting slots and slide downward to lock into place. All PDUs include
remote outlet control, reducing service calls by rebooting unresponsive
standard mounting brackets that support rack installation and surface
devices remotely and increasing runtime during power failures by
mounting (walls, counters, desktops, ceilings and more).
shedding nonessential loads.
Avoid Overloads
Provide Redundant Power
Included with Metered, Monitored and
Select Metered and Switched PDUs include dual AC inputs and an
Switched PDUs, digital load meters display
automatic transfer switch (ATS), providing redundant power to single-
current usage in real time, allowing you to
cord devices. If the primary power source fails or is taken off-line,
connect more equipment safely without
the PDU automatically switches to the secondary power source.
overloading the PDU.
P O W E R
D I S T R I B U T I O N
POWER DISTRIBUTION UNITS
Basic PDUs
Metered PDUs
Monitored PDUs
Yes
Yes
Yes
Yes
Vertical Models
Vertical Models
Vertical Models
Vertical Models
Automatic Transfer Switch (Includes redundant input power cords.)
–
Select Models
–
Select Models
Digital Load Meter (Displays current usage in real time.)
–
Yes
Yes
Yes
Network Interface (Enables remote management via SNMP, Web or telnet.)
–
–
Yes
Yes
Remote Individual Outlet Control (Turns outlets on or off from any location.)
–
–
–
Yes
Multiple Outlets (PDUs include up to 40 outlets.)
Toolless Mounting Buttons (Support industry-standard mounting slots.)
Switched PDUs
Go to www.tripplite.com for more information about Tripp Lite’s full line of PDUs, including an interactive PDU selector guide.
About Tripp Lite
Since 1922, Tripp Lite has established a global reputation for product
reliability, superior value and excellent service. Tripp Lite makes more
than 1,000 products to power, protect and connect electronic equipment,
including UPS systems, replacement batteries, PDUs, rack systems, cooling
solutions, surge suppressors, IP console servers, KVM switches, cables,
laptop accessories, power strips and inverters. Headquartered in Chicago,
Tripp Lite maintains offices worldwide. Learn more at www.tripplite.com.
Copyright © 2010 Tripp Lite. All trademarks are the sole property of their respective owners.
Tripp Lite has a policy of continuous improvement. Specifications are subject to change without
notice. Photos may differ slightly from actual products.
Tripp Lite World Headquarters
1111 W. 35th Street, Chicago, IL 60609 USA
773.869.1234 • www.tripplite.com
14-03-101 95-3111B
P O W E R
D I S T R I B U T I O N
U N I T S
PDU Comparison Chart
Feature
T
S
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF