advertisement
BLP-G
GAS FLOOR MODEL BRAISING PAN WITH
ELECTRIC POWER TILT
INSTALLATION – OPERATION – MAINTENANCE
BLODGETT OVEN COMPANY
www.blodgett.com
44 Lakeside Avenue, Burlington, Vermont 05401 USA Telephone (800) 331-5842, (802) 860-3700 Fax: (802) 864-0183
IMPORTANT NOTES FOR INSTALLATION AND OPERATION
It is recommended that this manual be read thoroughly and that all instructions be followed carefully. This manual should be retained for future reference.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.
WARNING: Improper installation, operation, adjustment, alteration, service or maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions thoroughly before installing, operating or servicing this equipment.
WARNING: Instructions to be followed the event that the operator of this appliance smells gas must be posted in a prominent location.
This information shall be obtained by consulting the local gas supplier.
Keep the appliance area free and clear from combustibles.
Do not obstruct the flow of combustion and ventilation air.
Adequate clearances must be maintained for servicing and proper operation.
CONTACT THE FACTORY, THE FACTORY REPRESENTATIVE OR A LOCAL SERVICE
COMPANY TO PERFORM MAINTENANCE AND REPAIRS SHOULD THE APPLIANCE
MALFUNCTION. REFER TO WARRANTY TERMS.
2
TABLE OF CONTENTS
DESCRIPTION PAGE
Important Notes for Installation and Operation ............................................................... 2
1.0 Service Connections ............................................................................................... 4
2.0 Installation Instructions ............................................................................................ 5
3.0 Operation Instructions ............................................................................................. 8
4.0 Periodic Maintenance ............................................................................................ 11
5.0 Cooking Guidelines ............................................................................................... 13
6.0 Troubleshooting .................................................................................................... 17
3
1.0 SERVICE CONNECTIONS
Unless otherwise specified, Field Wire Electrical Connection to be 120 Volts, 60 Hertz single phase with grounding
GAS CONNECTION: Supply gas through 3/4" pipe. A gas shut-off valve must be installed in supply piping convenient and adjacent to appliance.
COLD WATER: 3/8" O.D. tubing to faucet. (OPTIONAL)
HOT WATER: 3/8" O.D. tubing to faucet. (OPTIONAL)
MODEL
BLP-30G
BLP-40G
MODEL
BLP-30G
BLP-40G
37
[940]
33
[838]
BTU/HR.
80,000
100,000
kW/HR.
23.4
29.3
GAS SUPPLY
SUPPLY PIPE PRESSURE (W.C.)
Natural
7"-14" (178-356mm)
Propane
11"-14" (279-356mm)
CAPACITY
30 gallons
114 litres
40 gallons
152 litres
UNITS
inches mm inches mm
A
36
914
48
1219
B
33.5
851
45.5
1156
DIMENSIONS
C
D
74
1880
74
1880
13
330
13
330
E
28
711
28
711
F
12.5
318
12.5
318
G
14
356
15.5
394
H
4
102
4
102
J
13.88
352
32
813
K
6
152
6
152
L
33.5
851
43.5
1105
M
24
610
24
610
A
L
DIMENSIONS ARE IN INCHES [MM]
REAR FLANGED FOOT DETAIL
4
Ø
EQUALLY SPACED
7/16" [11mm] HOLES
ON 3 [76] B.C.
H
J
K
4.0 [101]
OPTIONAL FAUCET
B
19.25
[489]
POUR PATH
23.5 [597]
1.0 [26]
29.5 [750]
6[152] MINIMUM
4
2.0 INSTALLATION INSTRUCTIONS
UNPACKING
Immediately after unpacking, check for possible shipping damage. If the tilting braising pan is found to be damaged, save the packaging material and contact the carrier within
15 days of delivery.
Before installing, verify that the type of gas supply (natural or propane) and electrical service agree with the specifications on the rating plate located on the left side panel as you face the front of the braising pan. If the supply and equipment requirements do not agree, contact your dealer or Blodgett
LOCATION
The equipment must be kept free and clear of combustible substances. The tilting braising pan, when installed, must have minimum clearance from combustible and noncombustible construction of 3" (76 mm) from sides and 6" (152 mm) from the rear. The tilting braising pan is intended for use on non-combustible floors.
The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 36" (914 mm) is required.
The tilting braising pan must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber must be provided. Make sure there is an adequate supply of air in the room suitable for the amount of combustion gas feeding the braising pan burners.
Do not permit fans to blow directly at the tilting braising pan, and wherever possible, avoid open windows next to the tilting braising pan. Avoid wall-type fans which create air cross currents within the room.
INSTALLATION CODES AND STANDARDS
Gas installation to conform to local codes or in absence of local codes to National Fuel
Gas Code, ANSI Z223.1 - latest edition. In Canada, installation to be in accordance with
CAN/CGA- B149.1 (NAT) or B149.2 (LP) installation codes and/or local codes.
1. The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of ½ psig (3.45 kPa).
2. The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ psig (3.45 kPa).
Electrical grounding must be provided in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition. In
Canada installation must be in accordance with the CAN/CSA-C22.2, No.3 of the
Canadian Electrical Code, part 1.
5
FLUE CONNECTIONS
Do not obstruct the flow of flue gases from the flue duct located on the rear of the tilting braising pan. It is recommended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel.
Information on the construction and installation of ventilating hoods may be obtained from the standard for “Vapor Removal from Cooking Equipment”, NFPA No. 96 (latest edition), available from the National Fire Protection Association, Batterymarch Park,
Quincy, MA, 02269.
WARNING: ELECTRICAL GROUNDING INSTRUCTIONS
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug. (120V units only).
LEVELING AND ANCHORING
1. Set the appliance in place and level left to right and front-to-back using spirit level.
2. Mark hole locations on floor through anchoring holes provided in flanged adjustable feet.
3. Remove appliance and drill holes in locations marked on floor and insert proper anchoring devices (not supplied).
4. Set unit back in position and re-level left to right and front to back.
5. Bolt and anchor appliance securely to the floor.
6. Seal bolts and flanged feet with silastic or equivalent compound.
6
GAS CONNECTIONS
All gas supply connections and any pipe joint compound used must be resistant to the action of propane gases.
The gas inlet is located under the control panel on the left-hand side.
Connect gas supply to the tilting braising pan. The gas supply line must be at least the equivalent of 3/4" iron pipe with an incoming pressure of approximately 7" W.C. (Water
Column) for natural gas or 11" W.C. (Water Column) for propane gas. Make sure the pipes are clean and free of obstructions, dirt and piping compound.
Codes require that a gas shutoff valve be installed in the gas line ahead of the tilting braising pan.
Natural gas and propane gas braising pans are equipped with fixed orifices and no adjustment is necessary. Gas burner manifold is set at 3.5" W.C. (Water Column) for natural gas, and 10" W.C. (Water Column) for propane gas.
WARNING: Never use an open flame to check for gas leaks. Check all connections for leaks using soapy water before use.
After piping has been checked for leaks, all piping receiving gas should be fully purged to remove air.
7
3.0 OPERATION INSTRUCTIONS
BEFORE FIRST USE
CAUTION: The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance.
Using a non-corrosive, grease-dissolving commercial cleaner, clean the protective metal oils from all surface parts and the interior of the tilting braising pan. Follow the cleaner manufacturer’s directions. Rinse thoroughly and drain the pan. Wipe dry with a soft clean cloth.
CONTROLS
Green Ignition Light
Red Temperature Light
Will light when burners are supplying heat to the tilting braising pan.
Thermostat
-
- Will light when ignition has occurred.
When turned ON, will initiate electronic ignition system.
Temperature settings are marked on the control panel in
C and F.
Tilt Switch
Push UP to raise tilting braising pan; push DOWN to lower tilting braising pan.
RED TEMPERATURE LIGHT THERMOSTAT DIAL TILT SWITCH
LIGHTING PROCEDURE
SET THERMOSTAT IN OFF POSITION. OPEN GAS SUPPLY AND
ENSURE THAT THE SKILLET PAN IS IN THE DOWN POSITION.
TURN THERMOSTAT DIAL TO DESIRED SETTING. IF THE PILOT LIGHT IS NOT
ON AFTER TWO MINUTES, TURN OFF AND REPEAT THE LIGHTING
PROCEDURE.
DAILY SHUT DOWN PROCEDURE
TURN THERMOSTAT DIAL TO “OFF”, CLOSE MANUAL GAS SHUT OFF VALVE.
TILT
UP
DOWN
PILOT LIGHT OFF
READY
FIGURE 1
°F
°C
THERMOSTAT
8
START-UP PROCEDURE
1. Open manual gas shutoff valve.
2. Ensure that the braising pan is in the DOWN position.
3. Turn THERMOSTAT dial to desired setting. The red TEMPERATURE LIGHT will come on. This will turn on the electronic ignition which will light the burners.
4. If the green IGNITION LIGHT does not come on after 30 seconds, turn
THERMOSTAT OFF and then ON again for restart.
5. When braising pan has reached set temperature, the red TEMPERATURE LIGHT will go off and the burners will shut off. The burners will cycle on and off thereafter to maintain set temperature. The red TEMPERATURE LIGHT will be on when the burners are on and off when burners are off.
6. If gas supply is interrupted during operation, turn THERMOSTAT dial to OFF position and turn gas supply OFF. Wait 5 minutes, then repeat Steps 1 through 4 to restart.
7. Turn THERMOSTAT to OFF when braising pan is not in use.
DAILY SHUTDOWN PROCEDURE
Turn THERMOSTAT dial to OFF. Close manual gas shutoff valve.
9
TILTING THE BRAISING PAN
1. DO NOT try to tilt braising pan with lid down.
2. Make sure the receiving pan is in place.
3. To tilt braising pan, push and hold TILT SWITCH in the UP mode until desired pan position has been reached. The braising pan will empty when raised to the top tilt position. When the braising pan is raised 5 or more, the gas supply will be tuned off automatically. The braising pan will not operate once the pan has been tilted.
4. Food is poured through the removable strainer (Figure 2) into a food receiving pan positioned under the lip of the pouring spout (Figure 2).
5. To lower braising pan, push and hold TILT SWITCH in the DOWN mode.
NOTE: Excessive, consecutive lifts may cause the motor to overheat and activate the thermal overload causing the motor to shut down. Should this occur, a cooling off time will be necessary to reset and continue the lifting operation.
FIGURE 2
10
4.0 PERIODIC MAINTENANCE
WARNING: Disconnect the power supply to the appliance before cleaning or servicing.
CLEANING
After each use, allow the tilting braising pan to cool and clean it. Keep exposed cleanable areas of the tilting braising pan clean at all times. Do not get water in electrical box or any electrical component.
1. Thoroughly wash pan, pouring spout (See Figure 2), lid and exterior surfaces with detergent and warm water. If necessary, soak pan to remove food that is stuck to pan surface. Rinse thoroughly and wipe dry with a soft clean cloth.
2. Clean removable strainer and receiving pan support (see Figure 2) with detergent and warm water. Rinse thoroughly and wipe dry with a soft clean cloth.
3. Clean around burner air mixers and orifices (at rear of burner) if lint has accumulated.
4. Visually ensure tube lighter ports (Figure 3) are unobstructed.
FIGURE 3
11
CAUTION: The appliance and its parts are hot. Use care when operating, cleaning and servicing the appliance.
ADJUSTMENTS
All tilting braising pans are adjusted at the factory.
At least twice a year, have an authorized service person clean and adjust the tilting braising pan for maximum performance.
12
5.0 COOKING GUIDELINES
The guidelines given below are suggested quantities, temperature settings, and
estimated
numbers of orders per load and per hour. When two temperatures are given, the first is to start the product, and the second to finish the product.
The following temperatures should be used:
Simmering
Sautéing
Searing
Frying
Grilling
Temperature (
E
F)
200 Maximum
225 - 275
300 - 350
325 - 375
350 - 450
ITEM PORTION TEMP (F) BATCH/HR
BLP-30G PER LOAD
QTY PORTIONS
BREAKFAST FOODS
Bacon 3 slices
Eggs
- Boiled-Hard
- Boiled-Soft
- Fried
1 egg
1 egg
1 egg
- Poached
- Scrambled
French Toast
Regular
Oatmeal
Pancakes
1 egg
1-1/2 eggs
3 slices
½ cup
2 each
350
225
225
400
225
300-200
450
250
400
Clams
Fish Cakes
Haddock Fillet
Halibut Steak
Lobster
Swordfish
1 pt.
2 - 3 oz.
4 oz.
5 oz.
1 - 1 lb.
5 oz.
400
400
400
450
350
450
12
5
8
4
5
1
7
2
2 lbs.
50 eggs
50 eggs
30 eggs
36 eggs
18 gal.
35 slices
20 lbs.
(100 cups)
30 ea.
3
4
3
10
FISH
10
5
4
10 qts.
70 - 3 oz.
60 - 4 oz.
60 - 4 oz.
20 - 1 lb.
50 - 5 oz.
10
15
60
20
50
20
35
60
50
50
30
36
720
12
500
BLP-40G PER LOAD
QTY PORTIONS
3 lbs.
75 eggs
75 eggs
45 eggs
60 eggs
28 gal.
50 slices
40 lbs. (200 cups)
50 ea.
15 qts.
110 - 3 oz.
90 - 4 oz.
90 - 4 oz.
30 - 1 lb.
75 - 5 oz.
15
75
75
45
60
1100
17
1000
25
90
30
75
30
55
90
13
ITEM PORTION TEMP (F) BATCH/HR
BLP-30G PER LOAD
QTY PORTIONS
BLP-40G PER LOAD
QTY PORTIONS
Spinach
Turnips
FROZEN
Beans, French
Green
Lima Beans
Broccoli
Sliced Carrots
Small Whole
Carrots
Corn
Small Whole
Onions
Peas
Spinach
SAUCES, GRAVIES, SOUPS
Brown Gravy
Cream Sauce
1 oz.
2 oz.
Cream Soup
French Onion
Soup
6 oz.
6 oz.
4 oz.
Meat Sauce
VEGETABLES
CANNED
FRESH
Beans, Wax,
Green
Beets
3 oz.
3 oz.
Broccoli
Cabbage
Carrots
Cauliflower
Corn
Potatoes
3 oz.
3 oz.
3 oz.
3 oz.
3 oz.
1 ear
3 oz.
4 oz.
4 oz.
3 oz.
3 oz.
3 oz.
3 oz.
3 oz.
3 oz.
3 oz.
3 oz.
3 oz.
350 - 200
250 - 175
200
225
350 - 200
400
400
400
250
400
250
250
250
250
400
400
400
400
400
400
250
400
400
250
400
2
1
1
1
1
6
3
5
8
5
2
2
10
2
1
3
6
4
8
6
3
18
7
10
3
18 gal.
18 gal.
18 gal.
18 gal.
18 gal.
30 lbs.
25 lbs.
30 lbs.
25 lbs.
20 lbs.
35 lbs.
15 lbs.
50 ears
40 lbs.
6 lbs.
20 lbs.
15 lbs.
15 lbs.
12 lbs.
15 lbs.
15 lbs.
15 lbs.
15 lbs.
15 lbs.
15 lbs.
2300
1150
375
350
575
125
125
125
125
80
150
75
50
200
25
100
60
60
50
60
50
50
50
75
75
35 gal.
35 gal.
35 gal.
35 gal.
35 gal.
45 lbs.
50 lbs.
60 lbs.
40 lbs.
30 lbs.
70 lbs.
25 lbs.
75 ears
60 lbs.
9 lbs.
30 lbs.
22-1/2 lbs.
22-1/2 lbs.
18 lbs.
22-1/2 lbs.
22-1/2 lbs.
22-1/2 lbs.
22-1/2 lbs.
22-1/2 lbs.
22-1/2 lbs.
4500
2250
725
700
1100
200
90
90
75
90
90
90
90
110
110
250
300
200
125
300
125
75
300
35
150
14
ITEM PORTION TEMP (F)
Hamburger
Meatballs
Pot Roast
Salisbury Steak
Sirloin Steak
Swiss Steak
CHICKEN
Pan Fried
Whole
FRANKFURTERS
Grilled
Boiled
PORK
Ham Steak
Sausage Links
Pork Chops
DESSERTS, PUDDINGS, SWEET SAUCES
Butterscotch
Sauce
Cherry Cobbler
1 oz.
3 oz.
200
200
1 oz.
200 Chocolate
Sauce
Cornstarch
Pudding
Fruit Gelatin
MEAT-POULTRY
Bacon
4 oz.
3 oz.
3 slices
200
250
350
BEEF
Amer. Chop
Suey
Beef Stew
Corned Beef
Hash
Cheeseburger
6 oz.
8 oz.
5 oz.
3 oz.
400 - 225
300
400
300
3 oz.
1 oz.
2 oz.
5 oz.
6 oz.
4 oz.
300
400-225
350-200
400
400
300-200
2-1/4's
2 oz.
2 oz.
2 oz.
3 oz.
3 links
5 oz.
350
350-200
300
250
400
350
350
BATCH/HR
1
1
1
1
2
12
2
-
5
12
15
3
3
5
1
3
8
12
8
7
4
BLP-30G PER LOAD
QTY PORTIONS
18 gal.
18 gal.
18 gal.
18 gal.
18 gal.
2 lbs.
18 gal.
18 gal.
16 lbs.
7 lbs.
2300
750
2300
575
750
10
350
280
50
35
7 lbs.
35
12-1/2 lbs.
65
120 lbs.
500
16 lbs.
50
15 lbs.
25 lbs.
50 pieces
16 - 5 lbs.
22 lbs.
16 lbs.
10 lbs.
30 lbs.
15 lbs.
40
110
25
200
176
128
50
120
50
BLP-40G PER LOAD
QTY PORTIONS
35 gal.
35 gal.
35 gal.
35 gal.
35 gal.
3 lbs.
35 gal.
35 gal.
25 lbs.
10 lbs.
10 lbs.
18 lbs.
180 lbs.
24 lbs.
22-1/2 lbs.
40 lbs.
80 pieces
24-5 lbs.
33 lbs.
25 lbs.
15 lbs.
45 lbs.
25 lbs.
700
560
75
50
50
100
750
75
60
160
4500
1500
4500
1100
1500
15
40
265
264
200
75
180
75
15
ITEM PORTION TEMP (F) BATCH/HR
BLP-30G PER LOAD
QTY PORTIONS
MEAT-POULTRY (continued)
TURKEY
Off Carcass
On Carcass
2 oz.
2 oz.
MISCELLANEOUS
Grilled Cheese
Sandwich
1 sandwich
Macaroni &
Cheese
8 oz.
Rice
Spaghetti
4 oz.
4 oz.
400-200
400-200
400
200
350-225
350-225
–
–
8
2
1
2
3 26-30 lbs.
4 16-20 lbs.
35 sandwiches
18 gal.
20 lbs. raw
8 lbs. raw
200
175
35
300
320
200
BLP-40G PER LOAD
QTY PORTIONS
4 26-30 lbs.
6 16-20 lbs.
50 sand.
35 gal.
40 lbs. raw
12 lbs. raw
275
265
50
525
650
300
16
6.0 TROUBLESHOOTING
Burners do not come on:
1. Gas supply to unit is “OFF”.
2. Manual shut off valve is “OFF”.
3. Thermostat is not turned “ON”.
4. Pan not in lowest position.
5. Ignition control not functioning.
6. Unit electrical supply is not plugged in or turned on.
Burners produce carbon deposits:
1. Wrong size orifices.
2. Burner air not adjusted properly.
3. Wrong gas supply.
4. Incorrect pressure at supply.
17