Fujitsu PLAN EP OCe14102 Accessories

Fujitsu PLAN EP OCe14102 Accessories
Installation Guide - English
Fujitsu Local Area Network Adapter
Fujitsu PLAN EP OCe14102 2x 10Gb
Hardware and Software Installation Guide
Edition January 2015
Comments… Suggestions… Corrections…
The User Documentation Department would like to
know your opinion of this manual. Your feedback helps
us optimize our documentation to suit your individual
needs.
Feel free to send us your comments by e-mail to
manuals@ts.fujitsu.com.
Certified documentation
according to DIN EN ISO 9001:2008
To ensure a consistently high quality standard and
user-friendliness, this documentation was created to
meet the regulations of a quality management system
which complies with the requirements of the standard
DIN EN ISO 9001:2008.
cognitas. Gesellschaft für Technik-Dokumentation mbH
www.cognitas.de
Copyright and Trademarks
Copyright © 2015 Fujitsu Technology Solutions GmbH.
All rights reserved.
Delivery subject to availability; right of technical modifications reserved..
All hardware and software names used are trademarks of their respective manufacturers.
Table of Contents
Table of Contents
1. Introduction ................................................................................................................... 4
Major Features ........................................................................................................................ 4
Prerequisites .......................................................................................................................... 5
Adapter Identification ............................................................................................................. 5
2. Hardware Installation .................................................................................................... 6
Preparing the Adapter for Installation.................................................................................... 6
Installing the Adapter ............................................................................................................. 8
Attaching Devices ................................................................................................................... 8
Fujitsu PLAN EP OCe14102 Accessories .......................................................................... 11
Applying Power .................................................................................................................... 11
Viewing the LEDs .................................................................................................................. 11
3. Software Installation ................................................................................................... 13
First installation .................................................................................................................. 13
Update and manual installation ........................................................................................... 13
Emulex Management Utility OneCommand Manager (OCM) .............................................. 13
4. References ................................................................................................................... 14
Specifications ....................................................................................................................... 14
FCC and Regulatory Notices ................................................................................................ 15
Declarations of Conformity .................................................................................................. 17
Laser Safety Notice .............................................................................................................. 18
PLAN EP OCe14102 2x 10Gb
Page 3
1. Introduction
Prerequisites
1. Introduction
This manual describes the Fujitsu PLAN EP OCe14102 2x 10Gb PCI-Express adapter
for 10 Gigabits Enhanced Ethernet Fabric. This adapter provides ethernet networking
onto 10 Gigabit EE fabric.
This adapter supports NIC single root I/O virtualization (SR-IOV) and is fully compliant to
the PCI Express CEM Specification Rev. 3.0/2.0/1.1. The supported PCIe connector is
an x8.
Illustrations in this manual are only examples. The actual hardware may vary.
Figure 1-1 Fujitsu PLAN EP OCe14102 Adapter
Major Features









Sixteen PCIe functions configurable with offload features
Eight-lane (x8) Generation 3 PCIe interface at 8GT/s, 5GT/s, or 2.5GT/s
(auto-negotiated with system)
Low-profile PCIe form factor PCBA: 6.600 inches by 2.713 inches
Comes with low I/O bracket installed for low-profile cards; optional full height I/O
bracket is included in lose delivery unit.
Support for 10 GbE SFP+ optical or Direct-Attach Copper (DAC) connectors
SFF-8431 Enhanced Small Form Factor Pluggable Module SFP+ compliant
External volatile memory: 2Gb/4Gb DDR3 SDRAM technology
On-board flash memory: The flash is 128Mbit with a SPI interface. The flash
contains the vital product data (VPD) and Boot BIOS images. You can update
the flash with Emulex utilities.
Comprehensive array of NIC, operating system drivers, including support
for Windows, Linux, and VMware
PLAN EP OCe14102 2x 10Gb
Page 4
1. Introduction


Adapter Identification
Parts and construction compliant to the European Union Directive of Restriction
of Hazardous Substances (RoHS), and similar regulatory requirements for other
countries.
Protocol-specific capabilities
- NIC capabilities include:
- NDIS 5.2, 6.0, and 6.2-compliant Ethernet functionality
- IPv4/IPv6 TCP, UDP checksum offload
- IPv4/IPv6 Receive Side Scaling (RSS)
- IPv4/IPv6 Large Receive Offload (LRO)
- IPv4/IPv6 Large Send Offload (LSO)
- Programmable MAC addresses
- Up to 128 MAC/VLAN addresses
- Support for hash-based multicast MAC address filters
- Support for hash-based broadcast frame filters per port
- VLAN insertion and extraction
- Jumbo packet support up to 9200 bytes
Prerequisites

PCI Express 3.0/2.0/1.1 compliant systems: x8 lane at up to 8 Gb/s per lane.
Adapter Identification
Each adapter ships with several numbers clearly marked on the board. Fujitsu
recommends recording these numbers before installation.


IEEE address – a unique 64-bit identifier used for system configuration
Serial number – assigned by Emulex and used when communicating with
Emulex
Note: The adapter has two IEEE addresses, one for each port.
PLAN EP OCe14102 2x 10Gb
Page 5
2. Hardware Installation
Preparing the Adapter for Installation
2. Hardware Installation
The PLAN EP OCe14102 adapter can be connected to fiber optic cables (used with
embedded optical transceivers) or DAC cables. Additional information for these cable
connections and other installation procedures are described in the following sections.
Preparing the Adapter for Installation
Before installing the adapter, you should perform the following steps:
1. Turn off the computer and unplug it.
2. Remove the computer case.
Note: The adapter comes with a low-profile PCIe bracket installed. A hull height
bracket is included in the box with the adapter.
3. For the PLAN EP OCe14102 adapter, if you want to change the bracket to a low
profile version, follow steps 4–12; otherwise, proceed to “Installing the Adapter” on
page 10.
4. If the PLAN EP OCe14102 adapter contain optical transceiver, continue with the
following steps; otherwise, proceed to step 7.
Caution: This is a delicate operation–take care not to damage the optical
transceiver.
The adapter uses different types of optical transceivers. Figure 2-1 shows an
example of one type with the bail (handle) extended.
Figure 2-1 Typical Optical Transceiver
5. To remove a transceiver, pull the bail (handle) out and down to release the latch and
gently pull the transceiver out. Do not force it. After the latch is released, the
transceiver slides out easily.
Figure 2-2 shows a transceiver with the latch released (bail extended) and another
transceiver latched in place.
PLAN EP OCe14102 2x 10Gb
Page 6
2. Hardware Installation
Preparing the Adapter for Installation
Figure 2-2 Releasing the Latch on an Optical Transceiver
6. Observing Electrostatic Discharge (ESD) precautions, store the transceiver in an
ESD-safe place.
7. Remove the mounting bracket screws from the top of the adapter. Figure 2-3 shows
the screws that are removed from the bracket.
Figure 2-3 Removing the Bracket
8. Remove the bracket and store it for future use.
9. Align the new mounting bracket tabs with the holes in the adapter.
Note: Be careful not to push the bracket past the transceiver housing's grounding
tabs. Ensure the light emitting diodes (LEDs) are properly aligned with the
holes in the bracket.
PLAN EP OCe14102 2x 10Gb
Page 7
2. Hardware Installation
Installing the Adapter
10. Re-install the screws that attach the adapter to the bracket.
11. Re-install the transceiver by sliding it into the housing. When the latch engages, it
clicks.
12. Push the bail back into place.
Installing the Adapter
To install the adapter:
1. Turn off and unplug the computer.
2. Remove the computer case.
3. Remove the blank panel from an empty PCIe bus slot. See “Preparing the Adapter
for Installation” on page 8 to change the brackets if needed. Otherwise, proceed to
“Attaching Devices” on page 10.
Note: Place the adapter into an empty PCIe x8 or x16 slot. Make sure that the
adapter is in an appropriate PCIe slot that does not interfere with other
components or case to prevent damage to the adapter.
4. Insert the adapter into the empty x8 or x16 PCIe bus slot. Press firmly until the
adapter is seated.
5. Secure the adapter's mounting bracket to the case with a panel screw or clip.
6. Replace the computer case and tighten the case screws.
The adapter is now installed in the server and is ready for device attachment.
Attaching Devices
There are two types of cables that can be connected to the adapter:


Fibre optic cable
DAC cable
An adapter does not allow normal data transmission on either optical or copper links,
unless it is connected to a compatible optical or copper interface connection. The cable
and connector specifications are listed in Table 2-1, Cable and Connector
Specifications.
Note: Use Short Range (SR), Direct-connecting Receptacle (DCR) multimode fiber, or
SFP+ 10GbE copper cable for interface connections to a network that adheres
to the specifications listed in Table 2-1, Cable and Connector Specifications.
PLAN EP OCe14102 2x 10Gb
Page 8
2. Hardware Installation
Attaching Devices
Table 2-1 Cable and Connector Specifications
Maximum Length
(meters)
Cable Type
Minimum
Length (meters) Connector
Fiber Optic Cable for the PLAN EP OCe14102
LC
Short Range, LC-LC Multimode
OM3 – Multimode 50/125 micron fiber (2000
MHz*km bandwidth cable) with LC connectors:
1 Gbps (Not specified by IEEE 802.3)
10 Gbps
550
300
2
2
82
2
10 Gbps
26
2
10GbE Passive DAC Cable
5
0.5
10GbE Active DAC Cable
10
0.5
OM2 - Multimode 50/125 micron fiber (500
MHz*km bandwidth cable) with LC connectors:
10 Gbps
OM1 - Multimode 62.5/125 micron fiber (200
MHz*km bandwidth cable) with LC connectors:
Direct Attach
Copper
Direct Attach
Copper
To attach devices to the adapter:
1. Connect the appropriate cable to the adapter.
When connecting an optical cable, ensure the cages have optical transceivers
installed in them (see Figure 2-4).
Figure 2-4 Installing an Optical Transceiver
PLAN EP OCe14102 2x 10Gb
Page 9
2. Hardware Installation
Attaching Devices
Once the optical transceivers are installed, insert the optical cable into the LC
connectors on the adapter (see Figure 2-5).
Figure 2-5 Connecting a Fiber Optic Cable
When connecting a DAC cable, ensure the SFP+ cages do not have optical
transceivers installed in them. To remove optical transceivers, see step 5 on page 8.
After confirming there are no optical transceivers installed, insert the DAC
transceiver into the SFP+ cage on the adapter (see Figure 2-6).
.
Figure 2-6 Connecting a DAC Cable
2. After the appropriate cable is connected to the adapter, connect the other end of the
cable to a suitable device, such as a Top of Rack (TOR) EE switch.
After the device is connected to the adapter, you are ready to apply power to the
computer. See “Applying Power” on page 13.
PLAN EP OCe14102 2x 10Gb
Page 10
2. Hardware Installation
Applying Power
Fujitsu PLAN EP OCe14102 Accessories
Table 2-2 provides model number, name, interface and required quantities if you want
to order additional or replacement transceivers, or cables.
Table 2-2 Emulex OneConnect Accessories
Model Number
Model Name
Quantity
Interface
PLAN SFP+ MMF
OCE14102
SFP+ 10 Gigabit Ethernet
10GBASE-SR/SW Transceiver
1 pc
10Gbase-SR Optical
Applying Power
To apply power:
1.
2.
3.
4.
Verify that the adapter is securely installed in the computer.
Verify that the correct device is attached.
Plug in and turn on the computer.
Observe the boot banner for Power On Self Test (POST) results.
Viewing the LEDs
Each port connector has two LEDs: an amber LED and a green LED.
Amber LED (Link)


On (constantly) = Link up
Off = Link down
Green LED (Ethernet Activity)


Blink = Activity on the Ethernet link
Off = No activity on the Ethernet link
PLAN EP OCe14102 2x 10Gb
Page 11
2. Hardware Installation
Viewing the LEDs
Figure 2-7 Optical and DAC Adapter LED Indicators
PLAN EP OCe14102 2x 10Gb
Page 12
3. Software Installation
3. Software Installation
First installation
For the first installation please use the ServerView Installation Manager (SVIM). For
detailed information please refer to the ServerView Installation Manager manual
available on the web via:
http://manuals.ts.fujitsu.com/file/8396/sv-install-mgr-en.pdf
Update and manual installation
Fujitsu provides necessary driver and utilities on the web via:
http://support.ts.fujitsu.com/productselect.asp?lng=com&Level1=20966&lnid=3
Emulex Management Utility OneCommand Manager (OCM)
For Windows operating systems the Emulex Management Utility OneCommand
Manager (OCM) will be installed by SVIM automatically.
Under Linux operating systems a manual installation is necessary. Link to:
http://support.ts.fujitsu.com/productselect.asp?lng=com&Level1=20966&lnid=3
PLAN EP OCe14102 2x 10Gb
Page 13
4. References
Specifications
4. References
Specifications
Table 4-1 PLAN EP OCe14102 Adapter Specifications
Parameter
Range
Physical Dimensions
Low-profile form factor, 6.600 inches by 2.713 inches, and
accommodates both the full-height and low-profile bracket.
Power Requirements
PLAN EP OCe14102 adapter:
- 3.3V DC: 0.018 Watts (typical optical,10GbE and typical with
passive 10GbE direct-attach cable)
- 12V DC: 9.143 Watts (typical optical, 10GbE)
- 8.153 Watts (typical passive 10GbE direct-attach cable)
- 3.3V AUX: 0.018 Watts (typical optical,10GbE and typical with
passive 10GbE direct-attach cable)
Airflow
200 lf/min (minimum)
Temperature
0°C to 55°C (operating)
-40°C to 70°C (non-operating)
Note: Operating the adapter in higher temperatures and/or lower air
flow may result in premature failures.
Humidity
Operating: 10% to 90% RH, non-condensing, 22°C wet bulb
Non-operating: 5% to 95% RH, non-condensing, 22°C wet bulb
Agency Approvals for
PLAN EP OCe14102 adapter
•
•
•
•
•
•
•
Class 1 Laser Product per DHHS 21CFR (J) & EN60825-1 when
equipped with approved optical devices
UL recognized to UL60950-1 2nd Edition
cUR recognized to CSA 22.2, No. 60950-1-07
TUV certified to EN60950-1:2006 +A11 +A1 +A12
FCC Rules, Part 15, Subpart B, Class A
Industry Canada, ICES-003, Class A
EMC Directive 2004/108/EC (CE Mark)
EN55022:2010, Class A
•
•
•
•
•
•
•
Vibration, peak acceleration
EN55024:2010
Australian EMC Framework (C-Tick Mark)
AS/NZS CISPR22:2009 +A1, Class A
Japan VCCI, Class A
Taiwan BSMI, Class A
Korea MSIP, Class A (KN22 /KN24) referencing latest MSIP and
RRL notices
BSMI Class A, consisting of CNS 13438:2006 (complete edition)
RoHS Compliant (Directive 2011/65/EU)
China RoHS compliant
0.25g (5 Hz to 500 Hz)
(Sweep Rate = 1 octave/min.)
PLAN EP OCe14102 2x 10Gb
Page 14
4. References
FCC and Regulatory Notices
FCC and Regulatory Notices
OCe14000-series Adapters
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
Responsible Party:
Jeff Benck, President and Chief Executive Officer
Emulex Corporation (714) 662-5600
3333 Susan St. Costa Mesa, CA. 92626 USA
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation
of this equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense. The
reader is cautioned that changes or modifications made to the equipment not expressly
approved by Emulex could void the user's authority to operate this equipment. The
above statement applies to products marketed in the USA.
This class A digital apparatus meets all requirements of the Industry Canada (IC)
Interference - Causing Equipment Standard (ICES-003).
Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur
le matériel brouilleur du Canada. CAN ICES-3 (A)/ NMB-3 (A)
Notice for Japan and Translations (VCCI)
Translation:
This is a Class A product. If this equipment is used in a domestic environment, radio
interference may occur, in which case, the user may be required to take corrective
action. VCCI—A.
PLAN EP OCe14102 2x 10Gb
Page 15
4. References
FCC and Regulatory Notices
Notice for Taiwan and Translations (BSMI)
Translation:
This equipment is a Class A ITE, and operation of this equipment in a residential area is
likely to cause harmful interference, in which case users will be required to correct the
interference at their own expense.
Notice for South Korea and Translations (KCC)
Translation:
Sellers and users of this equipment take note that this equipment is EMC approved for
Class A industrial use, and as such is not intended for residential use.
PLAN EP OCe14102 2x 10Gb
Page 16
4. References
Declarations of Conformity
Declarations of Conformity
PLAN EP OCe14102 Adapter
This equipment complies with CISPR22/EN55022 Class A.
WARNING:
This is a class A product. In a domestic environment, this product may
cause radio interference requiring the user to take adequate measures.
Note: Changes or modifications not expressly approved by Emulex Corporation,
including the use of non-Emulex approved optical transceivers, could void the
user's authority to operate this equipment.
PLAN EP OCe14102 2x 10Gb
Page 17
4. References
Laser Safety Notice
Laser Safety Notice
Fujitsu products incorporating optical laser transceivers contain Class 1 laser devices,
which comply with DHHS/CDRH 21CFR Sub-chapter J, and the international laser
safety standard EN/IEC 60825-1. Class 1 laser devices are not considered to be
hazardous.
The use of non-Fujitsu approved optical transceivers, or transceivers which do not
comply with the Class 1 radiation performance requirements defined in DHHS/CDRH
21CFR Sub-chapter J and IEC 60825-1, may expose the user to hazardous laser
radiation, and such devices should not be used with Emulex products.
PLAN EP OCe14102 2x 10Gb
Page 18
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising