LOGO! - Encon
2
© Siemens AG 2013
LOGO! logic module
2/2
2/2
Introduction
LOGO! logic module
2/3
2/3
2/7
2/9
2/12
2/14
2/19
2/24
2/26
LOGO! modular
LOGO! modular basic variants
SIPLUS LOGO! modular basic variants
LOGO! modular pure variants
SIPLUS LOGO! modular pure variants
LOGO! modular expansion modules
SIPLUS LOGO! modular expansion
modules
LOGO! CM EIB/KNX communication
modules
LOGO! CSM unmanaged
AS-Interface connection for LOGO!
2/27
2/27
2/39
LOGO!Power
LOGO!Power
SIPLUS LOGO!Power
2/40
LOGO!Contact
2/41
LOGO! Software
2/23
Brochures
For brochures serving as selection
guides for SIMATIC products refer to:
www.siemens.com/simatic/
printmaterial
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
Introduction
LOGO! logic module
■ Overview
■ General technical data of the SIPLUS LOGO!
2
Ambient temperature range
-40/-25 ... +70 °C
Conformal coating
Coating of the printed circuit boards
and the electronic components
Technical data
The technical data of the standard
product applies except for the ambient conditions.
Ambient conditions
LOGO! logic module
• The compact, easy-to-use and low-cost solution for simple
control tasks
• Compact, easy to operate, universally applicable without
accessories
• "All in one": Integrated display and operator panel
• 36 different functions can be connected at the click of a button
or by means of PC software; up to 130 times over
• Functions are easily changed at the press of a key.
No more time-consuming rewiring
SIPLUS LOGO!
• The controller for use in the toughest environmental conditions
• With extended temperature range from -40/-25 °C to +70 °C
• Suitable for medial exposure (harmful gas atmosphere)
• Condensation permissible
• With the proven PLC technology of LOGO!
• Easy to handle, program, maintain, and service
• Ideal for use in automotive engineering, environmental
engineering, mining, chemical plants, material handling, food
industry, etc.
Accessories:
• The front panel mounting set also allows simple and reliable
installation of the logic modules in front panels; IP65
protection is thus possible.
• In order to ensure dependable operation of SIPLUS devices
supplied by the battery in conjunction with combustion
engines, it is necessary to put in a SIPLUS upmiter upstream
device between the battery and the SIPLUS LOGO!.
For further information, please go to:
http://www.siemens.com/siplus-extreme
For brochures serving as selection guides for SIMATIC products
refer to:
http://www.siemens.com/simatic/printmaterial
2/2
Siemens ST 70 · 2013
Relative humidity
100%, condensation/frost permissible. No commissioning if condensation present.
Biologically active substances,
compliance with EN 60721-3-3
Class 3B2 mold and fungal spores
(excluding fauna). The supplied
plug covers must remain in place
over the unused interfaces during
operation!
Chemically active substances,
compliance with EN 60721-3-3
Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree
of severity 3). The supplied plug
covers must remain in place over
the unused interfaces during operation!
Mechanically active substances,
compliance with EN 60721-3-3
Class 3S4 incl. sand, dust. The supplied plug covers must remain in
place over the unused interfaces
during operation!
Air pressure (depending on the
highest positive temperature range
specified)
1080 ... 795 hPa
(-1000 ... +2000 m)
see ambient temperature range
795 ... 658 hPa
(+2000 ... 3500 m)
derating 10 K
658 ... 540 hPa
(+3500 ... +5000 m)
derating 20 K
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular basic variants
■ Overview
• The space-saving basic variants
• Interface for the connection of expansion modules, up to
24 digital inputs, 16 digital outputs, 8 analog inputs and
2 analog outputs can be addressed
• With connection option for LOGO! text display TD
(can be connected to all LOGO! 0BA6 basic variants)
New in LOGO! 0BA7 variants:
• Ethernet interface for communication with SIMATIC Controller,
SIMATIC Panel and PC
• Networking of max. 8 LOGO! devices
• Use of standard SD card or SIMATIC memory card
■ Technical specifications
Installation type/mounting
Mounting
6ED1 052-1CC01-0BA6
6ED1 052-1MD00-0BA6
6ED1 052-1HB00-0BA6
6ED1 052-1FB00-0BA6
on 35 mm DIN rail,
4 spacing units wide
on 35 mm DIN rail,
4 spacing units wide
on 35 mm DIN rail,
4 spacing units wide
on 35 mm DIN rail,
4 spacing units wide
Supply voltage
12 V DC
24 V DC
Yes
Yes
Yes
Yes
115 V DC
Yes
230 V DC
Yes
permissible range,
lower limit (DC)
20.4 V
10.8 V
20.4 V
100 V
permissible range,
upper limit (DC)
28.8 V
28.8 V
28.8 V
253 V
Yes
24 V AC
115 V AC
Yes
230 V AC
Yes
Time of day
Time switching clocks
• Power reserve
80 h
80 h
80 h
80 h
8; Of which 4 can be used
in analog mode (0 to 10 V)
8; Of which 4 can be used
in analog mode (0 to 10 V)
8
8
Digital outputs
Number/binary outputs
4; Transistor
4; Relay
4; Relay
4; Relay
Functionality/short-circuit strength
Yes; electrical (1 A)
No; external fusing necessary
No; external fusing necessary
No; external fusing necessary
Output current
• for signal "1" permissible range for 0
to 55 °C, max.
0.3 A
3A
10 A
3A
10 A
3A
10 A
Yes; Radio interference
suppression according to
EN55011, Limit Value
Class B
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Digital inputs
Number/binary inputs
Relay outputs
• Switching capacity of contacts
- with inductive load, max.
- Switching frequency/contacts/
at ohmic load/maximum
EMC
Emission of radio interference acc. to
EN 55 011
• Emission of radio interference acc. to
EN 55 011 (limit class B)
Degree and class of protection
IP20
Siemens ST 70 · 2013
2/3
2
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular basic variants
■ Technical specifications (continued)
2
6ED1 052-1CC01-0BA6
6ED1 052-1MD00-0BA6
6ED1 052-1HB00-0BA6
6ED1 052-1FB00-0BA6
Standards, approvals, certificates
CSA approval
Yes
Yes
Yes
Yes
UL approval
Yes
Yes
Yes
Yes
FM approval
Yes
Yes
Yes
Yes
Marine approval
Yes
Yes
Yes
Yes
Developed according to IEC 61131
Yes
Yes
Yes
Yes
according to VDE 0631
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Min.
• max.
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
Dimensions
Width
72 mm
72 mm
72 mm
72 mm
Height
90 mm
90 mm
90 mm
90 mm
Depth
55 mm
55 mm
55 mm
55 mm
6ED1 052-1MD00-0BA7
6ED1 052-1FB00-0BA7
Installation type/mounting
Mounting
On 35 mm DIN rail, 6 spacing units wide
On 35 mm DIN rail, 6 spacing units wide
Supply voltage
12 V DC
Yes
24 V DC
Yes
115 V DC
Yes
230 V DC
Yes
permissible range, lower limit (DC)
10.8 V
100 V
permissible range, upper limit (DC)
28.8 V
253 V
115 V AC
Yes
230 V AC
Yes
Time of day
Time switching clocks
• Power reserve
480 h
480 h
Digital inputs
Number/binary inputs
8; Of which 4 can be used in analog mode (0 to 10 V)
8
Digital outputs
Number/binary outputs
4; Relay
4; Relay
Functionality/short-circuit strength
No; external fusing necessary
No; external fusing necessary
3A
10 A
3A
10 A
EMC
Emission of radio interference acc. to
EN 55 011
• Emission of radio interference acc. to
EN 55 011 (limit class B)
Yes; Radio interference suppression according to
EN55011, Limit Value Class B
Yes; Radio interference suppression according to
EN55011, Limit Value Class B
Degree and class of protection
IP20
Yes
Yes
Standards, approvals, certificates
CSA approval
Yes
Yes
UL approval
Yes
Yes
FM approval
Yes
Yes
Marine approval
Yes
Yes
Developed according to IEC 61131
Yes
Yes
according to VDE 0631
Yes
Yes
Relay outputs
• Switching capacity of contacts
- with inductive load, max.
- Switching frequency/contacts/at
ohmic load/maximum
2/4
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular basic variants
■ Technical specifications (continued)
6ED1 052-1MD00-0BA7
6ED1 052-1FB00-0BA7
Ambient conditions
Operating temperature
• Min.
• max.
0 °C
55 °C
0 °C
55 °C
Dimensions
Width
107 mm
107 mm
Height
90 mm
90 mm
Depth
55 mm
55 mm
■ Ordering data
LOGO! logic module 24C
Order No.
6ED1 052-1CC01-0BA6
24 V DC power supply,
8x 24 V DC digital inputs,
of which 4 can be used in analog
mode (0 to 10 V),
4x 24 V DC digital outputs, 0.3 A,
integral time switch;
200 function blocks can be interlinked,
modular expansion capability
LOGO! logic module 12/24RC
SIPLUS LOGO! TD text display
6ED1 052-1MD00-0BA6
LOGO! Manual
6ED1 052-1HB00-0BA6
115/230 V AC/DC power supply,
8x 115/230 V AC/DC digital inputs,
4x 10 A relay outputs,
integral time switch;
400 function blocks can be interlinked,
Ethernet interface,
modular expansion capability
German
6ED1 050-1AA00-0AE8
English
6ED1 050-1AA00-0BE8
French
6ED1 050-1AA00-0CE8
Spanish
6ED1 050-1AA00-0DE8
Italian
6ED1 050-1AA00-0EE8
Chinese
6ED1 050-1AA00-0KE8
LOGO! Memory Card
6ED1 056-1DA00-0BA0
Program module for copying,
with know-how protection
6ED1 052-1FB00-0BA6
LOGO! battery card
6ED1 056-6XA00-0BA0
Battery module for backing
up the integral real-time clock
(not LOGO! 24)
LOGO! memory/battery card
6ED1 052-1MD00-0BA7
12/24 V DC power supply,
8x 12/24 V DC digital inputs, of
which 4 can be used in analog
mode (0 to 10 V)
4x 10 A relay outputs,
integral time switch;
400 function blocks can be interlinked,
Ethernet interface,
modular expansion capability
LOGO! logic module 230RCE
6AG1 055-4MH00-2BA0
(extended temperature range
-10 ... +60 °C and medial loading)
4-line text display, can be connected to all LOGO! Basic and Pure
versions as of -0BA6, including connecting cable
115/230 V AC/DC power supply,
8x 115/230 V AC/DC digital inputs,
4x 10 A relay outputs,
integral time switch;
200 function blocks can be interlinked,
modular expansion capability
LOGO! logic module 12/24RCE
6ED1 055-4MH00-0BA0
4-line text display, can be connected to all LOGO! 0BA6 Basic
and Pure versions, including connecting cable
24 V AC/DC power supply,
8x 24 V AC/DC digital inputs,
4x 10 A relay outputs,
integral time switch;
200 function blocks can be interlinked,
modular expansion capability
LOGO! logic module 230RC
Order No.
Accessories
LOGO! TD text display
12/24 V DC power supply,
8x 12/24 V DC digital inputs, of
which 4 can be used in analog
mode (0 to 10 V)
4x 10 A relay outputs,
integral time switch;
200 function blocks can be interlinked,
modular expansion capability
LOGO! logic module 24RC
2
6ED1 056-7DA00-0BA0
Combined program and battery
module, with know-how protection
and for backing up the integral realtime clock (not LOGO! 24)
LOGO! PROM
6AG1 057-1AA01-0BA6
Programming device used to simultaneously reproduce program module contents on up to 8 program
modules
LOGO!Soft Comfort V7.0
6ED1 052-1FB00-0BA7
6ED1 058-0BA02-0YA1
For programming on the PC in
LAD/FBD; executes on Windows 7,
VISTA, XP, NT4.0, 2000, 98SE, Linux
and MAC OSX; on CD-ROM
LOGO!Soft Comfort V7.0 upgrade
6ED1 058-0CA02-0YE1
Upgrade from V1.0 to V7.0
Siemens ST 70 · 2013
2/5
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular basic variants
■ Ordering data
LOGO! PC cable
2
Order No.
6ED1 057-1AA00-0BA0
For program transfer between
LOGO! and the PC
LOGO! USB PC cable
In TANOS box, with USB cable,
LOGO!, LOGO! Soft Comfort V6
6ED1 057-1AA01-0BA0
For transferring the program
between LOGO! and PC,
including driver on CD-ROM
LOGO! modem cable
Order No.
LOGO! Starter kits (0BA6)
LOGO! Starter kit 12/24 V
Language-neutral
with LOGO! 12/24RC (0BA6)
6ED1 057-3BA00-0AA6
LOGO! Starter kit 230 V
6ED1 057-1CA00-0BA0
Adapter cable for analog modem
communication
Language-neutral
with LOGO! 230RC (0BA6)
6ED1 057-3BA02-0AA6
LOGO! Starter kits (0BA7)
Front panel mounting set
Width 4 MW
6AG1 057-1AA00-0AA0
Width 4 MW, with keys
6AG1 057-1AA00-0AA3
Width 8 MW
6AG1 057-1AA00-0AA1
Width 8 MW, with keys
6AG1 057-1AA00-0AA2
In TANOS box, with Ethernet cable,
LOGO!, LOGO! Soft Comfort V7,
WinCC Basic V11
LOGO! Starter kit 12/24 V
Language-neutral with
LOGO! 12/24RCE (0BA7) +
LOGO! Power 24 V 1.3 A
6ED1 057-3BA00-0AA7
LOGO! Starter kit 230 V
Language-neutral
with LOGO! 230RCE (0BA7)
2/6
Siemens ST 70 · 2013
6ED1 057-3BA02-0AA7
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular basic variants
■ Overview
• The space-saving basic variants
• Interface for the connection of expansion modules, up to
24 digital inputs, 16 digital outputs, 8 analog inputs and
2 analog outputs can be addressed
• With connection option for LOGO! text display TD
(can be connected to all LOGO! 0BA6 basic versions)
New in LOGO! 0BA7 variants:
• Ethernet interface for communication with SIMATIC Controller,
SIMATIC Panel and PC
• Networking of max. 8 LOGO! devices
• Use of standard SD card or SIMATIC memory card
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.
■ Technical specifications
The technical data correspond to those of the based-on
modules apart from the values listed in the table:
Based on
Ambient conditions
Operating temperature
• Min.
• max.
Extended ambient conditions
• Relative to ambient temperatureatmospheric pressure-installation
altitude
• Relative humidity
- with condensation
• Resistance
- to biologically active substances
- to chemically active substances
- to mechanically active substances
6AG1 052-1CC01-2BA6
6AG1 052-1MD00-2BA6
6AG1 052-1HB00-2BA6
6AG1 052-1FB00-2BA6
6ED1 052-1CC01-0BA6
6ED1 052-1MD00-0BA6
6ED1 052-1HB00-0BA6
6ED1 052-1FB00-0BA6
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Siemens ST 70 · 2013
2/7
2
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular basic variants
■ Technical specifications (continued)
2
6AG1 052-1MD00-2BA7
6AG1 052-1FB00-2BA7
Based on
6ED1 052-1MD00-0BA7
6ED1 052-1FB00-0BA7
Ambient conditions
Operating temperature
• Min.
• max.
-25 °C; = Tmin
70 °C; = Tmax
-25 °C; = Tmin
70 °C; = Tmax
Tmin ... Tmax at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K) at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K) at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m)
Extended ambient conditions
• Relative to ambient temperature-atmospheric pressure-installation altitude
• Relative humidity
- with condensation
• Resistance
- to biologically active substances
- to chemically active substances
- to mechanically active substances
■ Ordering data
SIPLUS LOGO! 24
100 %; Relative humidity, incl. condensation / frost permit- 100 %; Relative humidity, incl. condensation / frost permitted (no commissioning under condensation conditions)
ted (no commissioning under condensation conditions)
Yes; Class 3B2 mold, fungus and dry rot spores (with the
exception of fauna). The supplied connector covers must
remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray according to
EN 60068-2-52 (degree of severity 3). The supplied
connector covers must remain on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector
covers must remain on the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with the
exception of fauna). The supplied connector covers must
remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray according to
EN 60068-2-52 (degree of severity 3). The supplied
connector covers must remain on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand, dust. The supplied connector
covers must remain on the unused interfaces during operation!
Order No.
6AG1 052-1CC01-2BA6
Order No.
SIPLUS LOGO! 230RC
(extended temperature range and
medial exposure)
(Extended temperature range and
medial exposure)
24 V DC supply voltage,
8 digital inputs 24 V DC,
of which 4 can be used in analog
mode (0 to 10 V),
4 digital outputs 24 V DC, 0.3 A;
integrated time switch;
200 function blocks can be interlinked,
modular expansion capability
115/230 V AC/DC supply voltage,
8 digital inputs 115/230 V AC/DC,
4 relay outputs 10 A,
integral time switch;
200 function blocks can be interlinked,
modular expansion capability
SIPLUS LOGO! 12/24RC
(Extended temperature range and
medial exposure)
SIPLUS LOGO! 12/24RCE
6AG1 052-1MD00-2BA6
(Extended temperature range and
medial exposure)
(Extended temperature range and
medial exposure)
24 V AC/DC supply voltage,
8 digital inputs 24 V AC/DC,
4 relay outputs 10 A,
integral time switch;
200 function blocks can be interlinked,
modular expansion capability
6AG1 052-1MD00-2BA7
12/24 V DC supply voltage,
8 digital inputs 12/24 V DC,
of which 4 can be used in analog
mode (0 to 10 V)
4 relay outputs 10 A,
integral time switch;
400 function blocks can be interlinked,
Ethernet interface,
modular expansion capability
12/24 V DC supply voltage,
8 digital inputs 12/24 V DC,
of which 4 can be used in analog
mode (0 to 10 V),
4 relay outputs 10 A,
integral time switch;
200 function blocks can be interlinked,
modular expansion capability
SIPLUS LOGO! 24RC
6AG1 052-1FB00-2BA6
SIPLUS LOGO! 230RCE
6AG1 052-1HB00-2BA6
6AG1 052-1FB00-2BA7
(Extended temperature range and
medial exposure)
115/230 V AC/DC supply voltage,
8 digital inputs 115/230 V AC/DC,
4 relay outputs 10 A,
integral time switch;
400 function blocks can be interlinked,
Ethernet interface,
modular expansion capability
Accessories
SIPLUS Upmiter upstream device
6AG1 053-1AA00-2AA0
for reliable operation at the battery
of combustion engines
Additional accessories
2/8
Siemens ST 70 · 2013
See LOGO! modular
basic variants, page 2/5
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular pure variants
■ Overview
• The cost-optimized basic variants
• Interface for the connection of expansion modules, up to
24 digital inputs, 16 digital outputs, 8 analog inputs and
2 analog outputs can be addressed
• With connection option for LOGO! TD text display
(can be connected to all LOGO! 0BA6 basic variants)
■ Technical specifications
Installation type/mounting
Mounting
6ED1 052-2CC01-0BA6
6ED1 052-2MD00-0BA6
6ED1 052-2HB00-0BA6
6ED1 052-2FB00-0BA6
on 35 mm DIN rail,
4 spacing units wide
on 35 mm DIN rail,
4 spacing units wide
on 35 mm DIN rail,
4 spacing units wide
on 35 mm DIN rail,
4 spacing units wide
Supply voltage
12 V DC
24 V DC
Yes
Yes
Yes
Yes
115 V DC
Yes
Yes
230 V DC
permissible range, lower limit (DC)
20.4 V
10.8 V
20.4 V
100 V
permissible range, upper limit (DC)
28.8 V
28.8 V
28.8 V
253 V
24 V AC
Yes
115 V AC
Yes
230 V AC
Yes
Time of day
Time switching clocks
• Number
• Power reserve
190
80 h
8
80 h
8
80 h
8
80 h
8; Of which 4 can be used
in analog mode (0 to 10 V)
8; Of which 4 can be used
in analog mode (0 to 10 V)
8
8
Digital outputs
Number/binary outputs
4; Transistor
4; Relay
4; Relay
4; Relay
Functionality/short-circuit strength
Yes; electrical (1 A)
No; external fusing necessary
No; external fusing necessary
No; external fusing necessary
Output current
• for signal "1" permissible range
for 0 to 55 °C, max.
0.3 A
3A
10 A
3A
10 A
3A
10 A
Yes; Radio interference
suppression according to
EN55011, Limit Value
Class B
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Digital inputs
Number/binary inputs
Relay outputs
• Switching capacity of contacts
- with inductive load, max.
- Switching frequency/contacts/at
ohmic load/maximum
EMC
Emission of radio interference acc. to
EN 55 011
• Emission of radio interference acc. to
EN 55 011 (limit class B)
Degree and class of protection
IP20
Siemens ST 70 · 2013
2/9
2
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular pure variants
■ Technical specifications (continued)
2
6ED1 052-2CC01-0BA6
6ED1 052-2MD00-0BA6
6ED1 052-2HB00-0BA6
6ED1 052-2FB00-0BA6
Standards, approvals, certificates
CSA approval
Yes
Yes
Yes
Yes
UL approval
Yes
Yes
Yes
Yes
FM approval
Yes
Yes
Yes
Yes
Marine approval
Yes
Yes
Yes
Yes
Developed according to IEC 61131
Yes
Yes
Yes
Yes
according to VDE 0631
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Min.
• max.
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
Dimensions
Width
72 mm
72 mm
72 mm
72 mm
Height
90 mm
90 mm
90 mm
90 mm
Depth
55 mm
55 mm
55 mm
55 mm
■ Ordering data
LOGO! logic module 24Co
Order No.
6ED1 052-2CC01-0BA6
24 V DC power supply,
8 digital inputs 24 V DC,
of which 4 can be used in analog
mode (0 to 10 V),
4 digital outputs 24 V DC, 0.3 A,
integrated time switch;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
LOGO! logic module 12/24RCo
115/230 V AC/DC power supply,
8 digital inputs 115/230 V AC/DC,
4 relay outputs 10 A,
integral time clock;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
2/10
Siemens ST 70 · 2013
6ED1 055-4MH00-0BA0
4-line text display, can be
connected to all LOGO! 0BA6 Basic
and Pure versions, including connecting cable
SIPLUS LOGO! TD text display
6AG1 055-4MH00-2BA0
(extended temperature range
-10 ... +60 °C and medial loading)
6ED1 052-2MD00-0BA6
4-line text display, can be
connected to all LOGO! 0BA6 Basic
and Pure versions, including connecting cable
LOGO! Manual
6ED1 052-2HB00-0BA6
24 V AC/DC power supply,
8 digital inputs 24 V AC/DC,
4 relay outputs 10 A,
integral time switch;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
LOGO! logic module 230RCo
Accessories
LOGO! TD text display
12/24 V DC power supply,
8 digital inputs 12/24 V DC,
of which 4 can be used in analog
mode (0 to 10 V),
4 relay outputs 10 A,
integral time switch;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
LOGO! logic module 24RCo
Order No.
German
6ED1 050-1AA00-0AE8
English
6ED1 050-1AA00-0BE8
French
6ED1 050-1AA00-0CE8
Spanish
6ED1 050-1AA00-0DE8
Italian
6ED1 050-1AA00-0EE8
Chinese
6ED1 050-1AA00-0KE8
LOGO! Memory Card
6ED1 056-1DA00-0BA0
Program module for copying,
with know-how protection
LOGO! battery card
6ED1 052-2FB00-0BA6
Battery module for backing
up the integral real-time clock
(not LOGO! 24)
6ED1 056-6XA00-0BA0
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular pure variants
■ Ordering data
LOGO! memory/battery card
Order No.
6ED1 056-7DA00-0BA0
Combined program and battery
module, with know-how protection
and for backing up the integral realtime clock (not LOGO! 24o)
LOGO! PROM
LOGO! USB PC cable
6AG1 057-1AA01-0BA6
2
6ED1 058-0BA02-0YA1
6ED1 057-1AA01-0BA0
For transferring the program
between LOGO! and PC,
including driver on CD-ROM
LOGO! modem cable
6ED1 057-1CA00-0BA0
Adapter cable for analog modem
communication
LOGO! Starter kits (0BA6)
For programming on the PC in
LAD/FBD; executes on Windows 7,
VISTA, XP, NT4.0, 2000, 98SE, Linux
and MAC OSX; on CD-ROM
LOGO!Soft Comfort V7.0 upgrade
6ED1 057-1AA00-0BA0
For program transfer between
LOGO! and the PC
Programming device used to simultaneously reproduce program
module contents on up to 8 program
modules
LOGO!Soft Comfort V7.0
Order No.
LOGO! PC cable
LOGO! TD Starter kit
6ED1 058-0CA02-0YE1
Language-neutral
with LOGO! 12/24RCo + LOGO! TD
6ED1 057-3BA10-0AA6
Upgrade from V1.0 to V7.0
Siemens ST 70 · 2013
2/11
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular pure variants
■ Overview
• Basic variants optimized for costs
• Interface for the connection of expansion modules, up to
24 digital inputs, 16 digital outputs, 8 analog inputs and
2 analog outputs can be addressed
• With connection option for LOGO! text display TD
(can be connected to all LOGO! 0BA6 basic versions)
2
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.
■ Technical specifications
The technical data correspond to those of the based-on
modules apart from the values listed in the table:
Based on
Ambient conditions
Operating temperature
• Min.
• max.
Extended ambient conditions
• Relative to ambient temperatureatmospheric pressure-installation
altitude
• Relative humidity
- with condensation
• Resistance
- to biologically active substances
- to chemically active substances
- to mechanically active substances
2/12
Siemens ST 70 · 2013
6AG1 052-2CC01-2BA6
6AG1 052-2MD00-2BA6
6AG1 052-2HB00-2BA6
6AG1 052-2FB00-2BA6
6ED1 052-2CC01-0BA6
6ED1 052-2MD00-0BA6
6ED1 052-2HB00-0BA6
6ED1 052-2FB00-0BA6
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular pure variants
■ Ordering data
Order No.
Order No.
SIPLUS LOGO! 24o
Accessories
(extended temperature range and
medial exposure)
SIPLUS Upmiter upstream device
24 V DC supply voltage,
8 digital inputs 24 V DC,
of which 4 can be used in analog
mode (0 to 10 V),
4 digital outputs 24 V DC, 0.3 A,
integrated time switch;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
6AG1 052-2CC01-2BA6
6AG1 053-1AA00-2AA0
2
for reliable operation at the battery
of combustion engines
Additional accessories
See LOGO! modular pure
variants, page 2/10
SIPLUS LOGO! 12/24RCo
(extended temperature range and
medial exposure)
12/24 V DC supply voltage,
8 digital inputs 12/24 V DC,
of which 4 can be used in analog
mode (0 to 10 V),
4 relay outputs 10 A,
integral time switch;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
6AG1 052-2MD00-2BA6
SIPLUS LOGO! 24RCo
(extended temperature range and
medial exposure)
24 V AC/DC supply voltage,
8 digital inputs 24 V AC/DC,
4 relay outputs 10 A,
integral time switch;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
6AG1 052-2HB00-2BA6
SIPLUS LOGO! 230RCo
(extended temperature range and
medial exposure)
115/230 V AC/DC supply voltage,
8 digital inputs 115/230 V AC/DC,
4 relay outputs 10 A,
integral time switch;
without display and keyboard;
200 function blocks can be interlinked,
modular expansion capability
6AG1 052-2FB00-2BA6
Siemens ST 70 · 2013
2/13
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular expansion modules
■ Overview
• Expansion modules for connection to LOGO! modular
• With digital inputs and outputs, analog inputs, or analog
outputs
2
■ Technical specifications
Installation type/mounting
Mounting
6ED1 055-1CB00-0BA0
6ED1 055-1HB00-0BA0
6ED1 055-1MB00-0BA1
6ED1 055-1FB00-0BA1
on 35 mm DIN rail,
2 spacing units wide
on 35 mm DIN rail,
2 spacing units wide
on 35 mm DIN rail,
2 spacing units wide
on 35 mm DIN rail,
2 spacing units wide
Yes
Yes
Supply voltage
12 V DC
24 V DC
Yes
Yes
115 V DC
Yes
Yes
230 V DC
permissible range, lower limit (DC)
20.4 V
20.4 V
10.8 V
100 V
permissible range, upper limit (DC)
28.8 V
28.8 V
28.8 V
253 V
24 V AC
Yes
115 V AC
Yes
230 V AC
Yes
Digital inputs
Number/binary inputs
4
4
4
4
Input voltage
• Type of input voltage
DC
AC/DC
DC
AC/DC
Digital outputs
Number/binary outputs
4
4; Relay
4; Relay
4; Relay
Functionality/short-circuit strength
Yes; electrical (1 A)
No; external fusing necessary
No; external fusing necessary
No; external fusing necessary
3A
5A
3A
5A
3A
5A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Relay outputs
• Switching capacity of contacts
- with inductive load, max.
- Switching frequency/contacts/at
ohmic load/maximum
- Thermal continuous current, max.
EMC
Emission of radio interference acc. to
EN 55 011
• Emission of radio interference acc. to
EN 55 011 (limit class B)
Degree and class of protection
IP20
2/14
Siemens ST 70 · 2013
0.3 A
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular expansion modules
■ Technical specifications (continued)
6ED1 055-1CB00-0BA0
6ED1 055-1HB00-0BA0
6ED1 055-1MB00-0BA1
6ED1 055-1FB00-0BA1
Standards, approvals, certificates
CSA approval
Yes
Yes
Yes
Yes
UL approval
Yes
Yes
Yes
Yes
FM approval
Yes
Yes
Yes
Yes
Marine approval
Yes
Yes
Yes
Yes
Developed according to IEC 61131
Yes
Yes
Yes
Yes
according to VDE 0631
Yes
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Min.
• max.
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
Dimensions
Width
36 mm; 2 DU
36 mm; 2 DU
36 mm; 2 DU
36 mm; 2 DU
Height
90 mm
90 mm
90 mm
90 mm
Depth
55 mm
55 mm
55 mm
55 mm
Installation type/mounting
Mounting
Supply voltage
24 V DC
6ED1 055-1CB10-0BA0
6ED1 055-1NB10-0BA0
6ED1 055-1FB10-0BA0
on 35 mm DIN rail,
4 spacing units wide
on 35 mm DIN rail,
4 spacing units wide
on DIN rail 25 mm,
4 module spaces wide
Yes
Yes
115 V DC
Yes
Yes
230 V DC
permissible range, lower limit (DC)
20.4 V
20.4 V
100 V
permissible range, upper limit (DC)
28.8 V
28.8 V
253 V
115 V AC
Yes
230 V AC
Yes
Line frequency
• Frequency of the supply voltage
63 Hz
Digital inputs
Number/binary inputs
8
8
8
Input voltage
• Type of input voltage
• for signal "0"
• for signal "1"
DC
< 5 V DC
> 12 V DC
DC
< 5 V DC
> 12 V DC
AC/DC
< 40 V AC; < 30 V DC
> 79 V AC; > 79 V DC
1 mA
1 mA
0.03 mA
2 mA
2 mA
0.08 mA
1.5 ms
1.5 ms
1.5 ms
1.5 ms
50 ms
50 ms
Input current
• for signal "0", max.
(permissible quiescent current)
• for signal "1", typ.
Input delay
(for rated value of input voltage)
• for standard inputs
- at "0" to "1", max.
- at "1" to "0", max.
2
Siemens ST 70 · 2013
2/15
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular expansion modules
■ Technical specifications (continued)
2
6ED1 055-1CB10-0BA0
6ED1 055-1NB10-0BA0
6ED1 055-1FB10-0BA0
Digital outputs
Number/binary outputs
8
8; Relay
8; Relay
Functionality/short-circuit strength
Yes; electrical (1 A)
No; external fusing necessary
external fusing necessary
1 000 W; 500 W at 115 V AC
1 000 W; 500 W at 115 V AC
Lamp load, max.
Controlling a digital input
Yes
Yes
Yes
Parallel switching of 2 outputs
• for increased power
No
No
No
10 Hz
0.5 Hz
2 Hz
0.5 Hz
10 Hz
2 Hz
0.5 Hz
10 Hz
3A
5A
3A
5A
Yes
Yes
Yes
Degree and class of protection
IP20
Yes
Yes
Yes
Standards, approvals, certificates
CSA approval
Yes
Yes
Yes
UL approval
Yes
Yes
Yes
FM approval
Yes
Yes
Yes
Marine approval
Yes
Yes
Yes
Developed according to IEC 61131
Yes
Yes
Yes
according to VDE 0631
Yes
Yes
Yes
Ambient conditions
Operating temperature
• Min.
• max.
0 °C
55 °C
0 °C
55 °C
0 °C
55 °C
Dimensions
Width
72 mm; 4 WU
72 mm; 4 WU
72 mm; 4 WU
Height
90 mm
90 mm
90 mm
Depth
53 mm
53 mm
53 mm
Switching frequency
• with resistive load, max.
• with inductive load, max.
• mechanical, max.
Relay outputs
• Switching capacity of contacts
- with inductive load, max.
- Switching frequency/contacts/at
ohmic load/maximum
- Thermal continuous current, max.
EMC
Emission of radio interference acc. to
EN 55 011
• Emission of radio interference acc. to
EN 55 011 (limit class B)
0.3 A
6ED1 055-1MA00-0BA0
6ED1 055-1MD00-0BA1
Installation type/mounting
Mounting
on 35 mm DIN rail, 2 spacing units wide
Supply voltage
12 V DC
Yes
Yes; 10.8 to 28.8 V DC
24 V DC
Yes
Yes; 10.8 to 28.8 V DC
Analog inputs
Number of analog inputs
2
2; 2 or 3 wire connection
Input ranges
• Voltage
• Current
• Resistance thermometer
Yes
Yes
Yes; For PT100/PT1000 sensors
Input ranges (rated values), voltages
• 0 to +10 V
Yes
Input ranges (rated values), currents
• 0 to 20 mA
Yes
2/16
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular expansion modules
■ Technical specifications (continued)
6ED1 055-1MA00-0BA0
EMC
Emission of radio interference acc. to
EN 55 011
• Emission of radio interference acc. to
EN 55 011 (limit class B)
6ED1 055-1MD00-0BA1
2
Yes
Yes; Radio interference suppression according to
EN55011, Limit Value Class B
Degree and class of protection
IP20
Yes
Yes
Standards, approvals, certificates
CSA approval
Yes
Yes; C22.2 Number 142
UL approval
Yes
Yes; UL 508
FM approval
Yes
Yes; FM-Standards No. 3611, 3600, 3810 Class I,
Division 2, Group A, B, C, D
Marine approval
Yes
Yes; ABS, BV, DNV, GL, LRS, Class NK
Developed according to IEC 61131
Yes
Yes; EN 61131-2 (IEC 1131-2)
according to VDE 0631
Yes
Ambient conditions
Operating temperature
• Min.
• max.
0 °C
55 °C
0 °C
55 °C
Dimensions
Width
36 mm
36 mm
Height
90 mm
90 mm
Depth
55 mm
53 mm
6ED1 055-1MM00-0BA1
Installation type/mounting
Mounting
Supply voltage
12 V DC
24 V DC
Analog outputs
Number of analog outputs
Output ranges, voltage
• 0 to 10 V
EMC
Emission of radio interference acc. to
EN 55 011
• Emission of radio interference acc. to
EN 55 011 (limit class B)
Degree and class of protection
IP20
6ED1 055-1MM00-0BA1
Standards, approvals, certificates
CSA approval
Yes
UL approval
Yes
FM approval
Yes
Marine approval
Yes
Developed according to IEC 61131
Yes
2
according to VDE 0631
Yes
Yes
Ambient conditions
Operating temperature
• Min.
• max.
0 °C
55 °C
Dimensions
Width
36 mm
Height
90 mm
Depth
55 mm
on 35 mm DIN rail,
2 spacing units wide
No
Yes
Yes; Radio interference suppression according to EN55011, Limit
Value Class B
Yes
Siemens ST 70 · 2013
2/17
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! modular expansion modules
■ Ordering data
LOGO! DM8 24
2
Order No.
6ED1 055-1CB00-0BA0
Order No.
Accessories
Supply voltage 24 V DC,
4 digital inputs 24 V DC,
4 digital outputs 24 V DC, 0.3 A
LOGO! Manual
German
6ED1 050-1AA00-0AE8
LOGO! DM16 24
English
6ED1 050-1AA00-0BE8
French
6ED1 050-1AA00-0CE8
Spanish
6ED1 050-1AA00-0DE8
Italian
6ED1 050-1AA00-0EE8
Chinese
6ED1 050-1AA00-0KE8
LOGO! Memory Card
6ED1 056-1DA00-0BA0
6ED1 055-1CB10-0BA0
Supply voltage 24 V DC,
8 digital inputs 24 V DC,
8 digital outputs 24 V DC, 0.3 A
LOGO! DM8 12/24R
6ED1 055-1MB00-0BA1
Supply voltage 12/24 V DC,
4 digital inputs 12/24 V DC,
4 relay outputs 5 A
LOGO! DM8 24R
6ED1 055-1HB00-0BA0
LOGO!Soft Comfort V7.0
Supply voltage24 V AC/DC,
4 digital inputs 24 V AC/DC,
4 relay outputs 5 A
LOGO! DM16 24R
6ED1 055-1NB10-0BA0
Supply voltage 24 V DC,
8 digital inputs 24 V DC,
8 relay outputs 5 A
LOGO! DM8 230R
6ED1 055-1FB00-0BA1
6ED1 055-1FB10-0BA0
6ED1 055-1MA00-0BA0
6ED1 055-1MD00-0BA1
Supply voltage 12/24 V DC,
2 analog inputs Pt100,
temperature range -50 °C ... 200 °C
LOGO! AM2 AQ
Supply voltage 24 V DC,
2 analog outputs 0 to 10 V,
0/4 to 20 mA
2/18
Siemens ST 70 · 2013
LOGO! PC cable
For program transfer between
LOGO! and the PC
Supply voltage 12/24 V DC,
2 analog inputs 0 ... 10 V or
0 ... 20 mA, 10-bit resolution
LOGO! AM2 PT 100
6ED1 058-0CA02-0YE1
Upgrade from V1.0 to V7.0
Supply voltage 115/230 V AC/DC,
8 digital inputs 115/230 V AC/DC,
8 relay outputs 5 A
LOGO! AM2
6ED1 058-0BA02-0YA1
For programming on the PC in
LAD/FBD; executes on Windows 7,
VISTA, XP, NT4.0, 2000, 98SE, Linux
and MAC OSX; on CD-ROM
LOGO!Soft Comfort V7.0 upgrade
Supply voltage 115/230 V AC/DC,
4 digital inputs 115/230 V AC/DC,
4 relay outputs 5 A
LOGO! DM16 230R
for copying,
with know-how protection
6ED1 055-1MM00-0BA1
6ED1 057-1AA00-0BA0
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular expansion modules
■ Overview
• Expansion modules for connection to LOGO! modular
• With digital inputs and outputs, analog inputs, or analog
outputs
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.
■ Technical specifications
The technical data correspond to those of the based-on
modules apart from the values listed in the table:
Based on
Ambient conditions
Operating temperature
• Min.
• max.
Extended ambient conditions
• Relative to ambient temperature-atmospheric pressure-installation altitude
• Relative humidity
- with condensation
• Resistance
- to biologically active substances
- to chemically active substances
- to mechanically active substances
6AG1 055-1CB00-2XB0
6AG1 055-1CB00-2BY0
6AG1 055-1PB00-2XB0
6AG1 055-1PB00-2BY0
6ED1 055-1CB00-0BA0
6ED1 055-1CB00-0BA0
6ED1 055-1CB00-0BA0
6ED1 055-1CB00-0BA0
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Siemens ST 70 · 2013
2/19
2
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular expansion modules
■ Technical specifications (continued)
2
Based on
Ambient conditions
Operating temperature
• Min.
• max.
Extended ambient conditions
• Relative to ambient temperatureatmospheric pressure-installation
altitude
• Relative humidity
- with condensation
• Resistance
- to biologically active substances
- to chemically active substances
- to mechanically active substances
6AG1 055-1HB00-2XB0
6AG1 055-1HB00-2BY0
6AG1 055-1MB00-2XB1
6AG1 055-1MB00-2BY1
6ED1 055-1HB00-0BA0
6ED1 055-1HB00-0BA0
6ED1 055-1MB00-0BA1
6ED1 055-1MB00-0BA1
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @
UL/cUL use
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
100 %; Relative humidity,
incl. condensation / frost
permitted (no commissioning under condensation
conditions)
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
Yes; Class 3B2 mold, fungus and dry rot spores (with
the exception of fauna). The
supplied connector covers
must remain on the unused
interfaces during operation!
Yes; Class 3C4 incl. salt
spray. The supplied connector covers must remain
on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand,
dust. The supplied connector covers must remain on
the unused interfaces during operation!
6AG1 055-1FB00-2XB1
6AG1 055-1FB00-2BY1
6AG1 055-1NB10-2BA0
Bades on
6ED1 055-1FB00-0BA1
6ED1 055-1FB00-0BA1
6ED1 055-1NB10-0BA0
Ambient conditions
Operating temperature
• Min.
• max.
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @ UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @ UL/cUL use
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @ UL/cUL use
Extended ambient conditions
• Relative to ambient temperatureatmospheric pressure-installation
altitude
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
100 %; Relative humidity, incl.
condensation / frost permitted
(no commissioning under condensation conditions)
100 %; Relative humidity, incl.
condensation / frost permitted
(no commissioning under condensation conditions)
100 %; Relative humidity, incl.
condensation / frost permitted
(no commissioning under condensation conditions)
Yes; Class 3B2 mold, fungus and
dry rot spores (with the exception of
fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand, dust.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3B2 mold, fungus and
dry rot spores (with the exception of
fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray.
The supplied connector covers must
remain on the unused interfaces during operation!
Yes; Class 3S4 incl. sand, dust.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3B2 mold, fungus and
dry rot spores (with the exception of
fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand, dust.
The supplied connector covers
must remain on the unused interfaces
during operation!
• Relative humidity
- with condensation
• Resistance
- to biologically active substances
- to chemically active substances
- to mechanically active substances
2/20
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular expansion modules
■ Technical specifications (continued)
6AG1 055-1MA00-2XB0
6AG1 055-1MA00-2BY0
6AG1 055-1MM00-2BY1
Based on
6ED1 055-1MA00-0BA0
6ED1 055-1MA00-0BA0
6ED1 055-1MM00-0BA1
Ambient conditions
Operating temperature
• Min.
• max.
-25 °C; = Tmin
70 °C; = Tmax; 55 °C @ UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @ UL/cUL use
-40 °C; = Tmin
70 °C; = Tmax; 55 °C @ UL/cUL use
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
Tmin ... Tmax
at 1080 hPa ... 795 hPa
(-1000 m ... +2000 m) //
Tmin ... (Tmax - 10K)
at 795 hPa ... 658 hPa
(+2000 m ... +3500 m) //
Tmin ... (Tmax - 20K)
at 658 hPa ... 540 hPa
(+3500 m ... +5000 m)
100 %; Relative humidity, incl.
condensation / frost permitted
(no commissioning under condensation conditions)
100 %; Relative humidity, incl.
condensation / frost permitted
(no commissioning under condensation conditions)
100 %; Relative humidity, incl.
condensation / frost permitted
(no commissioning under condensation conditions)
Yes; Class 3B2 mold, fungus and
dry rot spores (with the exception of
fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand, dust.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3B2 mold, fungus and
dry rot spores (with the exception of
fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand, dust.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3B2 mold, fungus and
dry rot spores (with the exception of
fauna). The supplied connector covers must remain on the unused interfaces during operation!
Yes; Class 3C4 incl. salt spray.
The supplied connector covers
must remain on the unused interfaces
during operation!
Yes; Class 3S4 incl. sand, dust.
The supplied connector covers
must remain on the unused interfaces
during operation!
Extended ambient conditions
• Relative to ambient temperatureatmospheric pressure-installation
altitude
• Relative humidity
- with condensation
• Resistance
- to biologically active substances
- to chemically active substances
- to mechanically active substances
Siemens ST 70 · 2013
2
2/21
© Siemens AG 2013
LOGO! logic module
LOGO! modular
SIPLUS LOGO! modular expansion modules
■ Ordering data
2
Order No.
Order No.
SIPLUS LOGO! DM8 24
SIPLUS LOGO! AM2
(extended temperature range and
medial exposure)
(extended temperature range and
medial exposure)
24 V DC supply voltage,
4 digital inputs 24 V DC,
4 digital outputs 24 V DC, 0.3 A
12/24 V DC supply voltage,
2 analog inputs 0 ... 10 V or
0 ... 20 mA, 10-bit resolution
Temperature range -25 ... +70 °C
6AG1 055-1CB00-2XB0
Temperature range -25 ... +70 °C
6AG1 055-1MA00-2XB0
Temperature range -40 ... +70 °C
6AG1 055-1CB00-2BY0
Temperature range -40 ... +70 °C
6AG1 055-1MA00-2BY0
SIPLUS LOGO! DM8 12/24
SIPLUS LOGO! AM2 AQ
(extended temperature range and
medial exposure)
(extended temperature range and
medial exposure)
12/24 V DC supply voltage,
4 digital inputs 12/24 V DC,
4 digital outputs 24 V DC, 0.3 A
24 V DC supply voltage,
2 analog inputs 0 ... 10 V,
0/4 ... 20 mA, 10-bit resolution
Temperature range -25 ... +70 °C
6AG1 055-1PB00-2XB0
Temperature range -40 ... +70 °C
Temperature range -40 ... +70 °C
6AG1 055-1PB00-2BY0
SIPLUS LOGO! DM16 24R
(extended temperature range and
medial exposure)
SIPLUS LOGO! DM8 24R
(extended temperature range and
medial exposure)
24 V DC supply voltage,
8 digital outputs 24 V DC,
8 relay outputs 5 A
24 V AC/DC supply voltage,
4 digital inputs 24 V AC/DC,
4 relay outputs 5 A
Temperature range -25 ... +70 °C
Temperature range -25 ... +70 °C
6AG1 055-1HB00-2XB0
Accessories
Temperature range -40 ... +70 °C
6AG1 055-1HB00-2BY0
SIPLUS Upmiter upstream device
(extended temperature range and
medial exposure)
Additional accessories
12/24 V DC supply voltage,
4 digital inputs 12/24 V DC,
4 relay outputs 5 A
Temperature range -25 ... +70 °C
6AG1 055-1MB00-2XB1
Temperature range -40 ... +70 °C
6AG1 055-1MB00-2BY1
SIPLUS LOGO! DM8 230R
(extended temperature range and
medial exposure)
115/230 V AC/DC supply voltage,
4 digital inputs 115/230 V AC/DC,
4 relay outputs 5 A
Temperature range -25 ... +70 °C
6AG1 055-1FB00-2XB1
Temperature range -40 ... +70 °C
6AG1 055-1FB00-2BY1
Siemens ST 70 · 2013
6AG1 055-1NB10-2BA0
6AG1 053-1AA00-2AA0
for reliable operation at the battery
of combustion engines
SIPLUS LOGO! DM8 12/24R
2/22
6AG1 055-1MM00-2BY1
See LOGO! modular pure
variants, page 2/18
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! CM EIB/KNX communication modules
■ Overview
■ Technical specifications
CM EIB/KNX
• Expansion module for LOGO! basic versions
• For communication between the LOGO! master and external
EIB components through EIB
Supply voltage
24 V AC/DC
Inputs, max.
16 DI/12 DO/8 AI/2 AO
Outputs, max.
16 digital
Continuous current
25 mA
Short-circuit protection
External fuse protection is required
Integrated time switches/power
reserve
-
Ambient temperature
0 … +55°C
RI specification
To EN 55 011 (limit class B)
Degree of protection
IP20
Certification
to VDE 0631, IEC61131-2, cULus,
FM
Mounting
On DIN rail 35 mm,
2 module widths wide
Dimensions (W x H x D) in mm
36 (2 MW) × 90 × 55
■ Ordering data
LOGO! communication module
CM EIB KNX
2
Order No.
6BK1 700-0BA00-0AA2
for connection to EIB,
supply voltage 24 V DC
Accessories
LOGO! Manual
German
6ED1 050-1AA00-0AE8
English
6ED1 050-1AA00-0BE8
French
6ED1 050-1AA00-0CE8
Spanish
6ED1 050-1AA00-0DE8
Italian
6ED1 050-1AA00-0EE8
Chinese
6ED1 050-1AA00-0KE8
Siemens ST 70 · 2013
2/23
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! CSM unmanaged
■ Overview
The module is used to connect a LOGO! and up to three other
nodes to an Industrial Ethernet network with 10/100 Mbit/s in an
electrical linear, tree or star topology.
2
The essential features of the LOGO! CSM are:
• Unmanaged 4-port switch, of which one port is on the front for
easy diagnostics access
• Two versions for the voltage ranges 12/24 V DC or
230 V AC/DC
• Problem-free connection using four RJ45 standard
connectors
• Space-saving, optimized for connection to LOGO!
• Low-cost solution for implementing small, local Ethernet
networks
• Stand-alone use for networking any Ethernet devices
■ Technical specifications
Order No.
6GK7 177-1FA100AA0
6GK7 177-1MA100AA0
Product-type designation
LOGO! CSM 230
LOGO! CSM 12/24
Transmission rate
Transfer rate 1
Transfer rate 2
10 Mbit/s
100 Mbit/s
10 Mbit/s
100 Mbit/s
Interfaces
Number of electrical/optical
connections for network components or terminal equipment
maximum
Number of electrical connections
• for network components and
terminal equipment
• for power supply
Design of electrical connection
• for network components and
terminal equipment
• for power supply
4
4
4
4
1
1
RJ45 port /
1 connection on
front of module
3-pole terminal
block
RJ45 port /
1 connection on
front of module
3-pole terminal
block
Type of voltage of supply
voltage
AC/DC 115...240 V
DC 12/24 V
Supply voltage external
• minimum
• maximum
230 V
100 V
240 V
24 V
10.2 V
30.2 V
Product component fusing at
power supply input
Consumed current maximum
Active power loss at 24 V
for DC
Yes
Yes
0.02 A
-
0.15 A
1.5 W
0 … 55 °C
-40 °C 70 °C
-40 °C
0 … 55 °C
-40 °C 70 °C
-40 °C
Permitted ambient conditions
2/24
6GK7 177-1FA100AA0
6GK7 177-1MA100AA0
Product-type designation
LOGO! CSM 230
LOGO! CSM 12/24
Relative humidity at 25 °C
without condensation during
operating maximum
90 %
90 %
Protection class IP
IP20
IP20
Design, dimensions and
weight
Design
LOGO! module
LOGO! module
Width
Height
Depth
72 mm
90 mm
55 mm
72 mm
90 mm
55 mm
Net weight
0.155 kg
0.14 kg
Type of mounting
• 35 mm DIN rail mounting
• wall mounting
• S7-300 rail mounting
Yes
Yes
No
Yes
Yes
No
No
No
avail. soon
avail. soon
Yes
Yes
No
avail. soon
avail. soon
Yes
Yes
No
Product functions
Management, configuration
Product function
switch-managed
Supply voltage, current
consumption, power loss
Ambient temperature
• during operating
• during storage
• during transport
Order No.
Siemens ST 70 · 2013
Standards, specifications,
approvals
Standard
• for EMC from FM
• for safety of CSA and UL
• CE mark
• C-Tick
• KC approval
© Siemens AG 2013
LOGO! logic module
LOGO! modular
LOGO! CSM unmanaged
■ Ordering data
Order No.
LOGO! CSM Compact Switch
Modules
Unmanaged switch for connecting
a LOGO! (...0BA7) and up to three
further nodes on Industrial Ethernet
with 10/100 Mbit/s; 4 x RJ45 ports;
LED diagnostics, LOGO! module
• LOGO! CSM 12/24
external 12 V DC or 24 V DC
power supply,
• LOGO! CSM 230
external 115 ... 240 V AC
power supply
Order No.
Accessories
IE TP Cord RJ45/RJ45
6GK7 177-1MA10-0AA0
6GK7 177-1FA10-0AA0
2
TP cable 4 x 2 with 2 RJ45
connectors
• 0.5 m
•1m
•2m
•6m
• 10 m
6XV1 870-3QE50
6XV1 870-3QH10
6XV1 870-3QH20
6XV1 870-3QH60
6XV1 870-3QN10
IE FC Outlet RJ45
6GK1 901-1FC00-0AA0
For connecting Industrial Ethernet
FC cables and TP cords; graduated
prices for 10 and 50 units or more
Siemens ST 70 · 2013
2/25
© Siemens AG 2013
LOGO! logic module
LOGO! modular
AS-Interface connection for LOGO!
■ Overview
2
■ Ordering data
Each LOGO! can now be connected
to the AS-Interface system
An intelligent slave can be integrated into the AS-Interface
system with the AS-Interface for LOGO! The modular interface
allows the different basic units to be integrated into the system
depending on the required functionality. In addition, the functionality can be quickly and simply adapted to changed requirements by replacing the basic unit.
The interface provides four inputs and four outputs for the
system. These I/Os, however, are not implemented in hardware,
but are only virtually available via the interface.
2/26
Siemens ST 70 · 2013
AS-Interface connection
for LOGO!
Order No.
3RK1 400-0CE10-0AA2
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Overview
no-load operation has been cut in half. The wide-range input
now also allows operation with direct voltage, the switch-on
behavior has been optimized for capacitive loads, and the
operating temperature range has been extended to +70 °C. The
power supplies with logic module design can be used extremely
flexibly in numerous applications – thanks to their flat, stepped
profile in distribution boards, for example.
The flat power supply unit for distribution boards
The new miniature power supply units now offer even greater
performance in the smallest space: The efficiency has been
improved across the entire load range, and the power loss in
Essential product features
• 2 performance classes, each with 5 V, 12 V, and 15 V
• 3 performance classes with 24 V
• Flat LOGO! design
• Wide-range input for 85 V to 264 V AC or 110 V to 300 V DC
• Constant current for connection of loads with high inrush
current
• Power reserve on starting up through 1.5 times the rated
current for capacitive loads
• Adjustable output voltage
• Green LED for "Output voltage OK"
• Temperature range from –20 °C to +70 °C
• Comprehensive certification, e.g. ATEX and GL
■ Technical specifications
Order No.
6EP1 311-1SH03
6EP1 311-1SH13
Product
LOGO!Power
LOGO!Power
Power supply, type
5 V/3 A
5 V/6.3 A
Input
1-phase AC or DC
1-phase AC or DC
Rated voltage value Vin rated
100 … 240 V
100 … 240 V
Voltage range
85 … 264 V
85 … 264 V
Input voltage at DC
110 … 300 V
110 … 300 V
Overvoltage resistance
2.3 × Vin rated, 1.3 ms
2.3 × Vin rated, 1.3 ms
Mains buffering at Iout rated, min.
0.04 s
0.04 s
Mains buffering
at Vin = 187 V
at Vin = 187 V
Rated line frequency
•1
•2
50 Hz
60 Hz
50 Hz
60 Hz
Rated line range
47 … 63 Hz
47 … 63 Hz
0.36 A
0.71 A
0.22 A
0.37 A
Switch-on current limiting (+25 °C),
max.
26 A
50 A
I²t, max.
0.8 A²·s
3 A²·s
Built-in incoming fuse
internal
internal
Protection in the mains power input
(IEC 898)
Recommended miniature circuit breaker: from 16 A,
characteristic B or from 10 A, characteristic C
Recommended miniature circuit breaker: from 16 A,
characteristic B or from 10 A, characteristic C
Input
Input current
• at nominal level of the input voltage
120 V nominal value
• at nominal level of the input voltage
230 V nominal value
Siemens ST 70 · 2013
2/27
2
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
2
Order No.
6EP1 311-1SH03
6EP1 311-1SH13
Product
LOGO!Power
LOGO!Power
Power supply, type
5 V/3 A
5 V/6.3 A
Output
Controlled, isolated DC voltage
Controlled, isolated DC voltage
Rated voltage Vout DC
5V
5V
Total tolerance, static ±
3%
3%
Static mains compensation, approx.
0.2 %
0.1 %
Static load balancing, approx.
1.5 %
2%
Residual ripple peak-peak, max.
100 mV
100 mV
Residual ripple peak-peak, typ.
10 mV
15 mV
Spikes peak-peak, max.
(bandwidth: 20 MHz)
100 mV
100 mV
Spikes peak-peak, typ.
(bandwidth: 20 MHz)
20 mV
70 mV
Adjustment range
4.6 … 5.4 V
4.6 … 5.4 V
Product feature output voltage
adjustable
Yes
Yes
Output voltage setting
via potentiometer
via potentiometer
Status display
Green LED for output voltage OK
Green LED for output voltage OK
On/off behavior
No overshoot of Vout (soft start)
No overshoot of Vout (soft start)
Startup delay, max.
0.5 s
0.5 s
Voltage rise, typ.
20 ms
10 ms
Rated current value Iout rated
3A
6.3 A
Current range
0…3A
0 … 6.3 A
Note
3 A up to +55 °C, 2.1 A up to +70 °C
6.3 A up to +55 °C, 4.4 A up to +70 °C
delivered active power typ.
15 W
30 W
Parallel switching for enhanced
performance
Yes
Yes
Numbers of parallel switchable units
for enhanced performance
2
2
Efficiency at Vout rated, Iout rated,
approx.
77 %
83 %
Power loss at Vout rated, Iout rated,
approx.
4W
6W
Dynamic mains compensation
(Vin rated ±15 %), max.
0.2 %
0.2 %
Dynamic load smoothing
(Iout: 10/90/10 %), Uout ± typ.
3%
3%
Load step setting time 10 to 90%, typ.
2 ms
2 ms
Load step setting time 90 to 10%, typ.
2 ms
2 ms
Output overvoltage protection
Yes, according to EN 60950
Yes, according to EN 60950
Current limitation, typ.
3.8 A
8.2 A
Characteristic feature of the output
short-circuit protected
Yes
Yes
Short-circuit protection
Constant current characteristic
Constant current characteristic
Enduring short circuit current Effective
level maximum
5A
10 A
Overload/short-circuit indicator
-
-
Output
Efficiency
Closed-loop control
Protection and monitoring
2/28
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
Order No.
6EP1 311-1SH03
6EP1 311-1SH13
Product
LOGO!Power
LOGO!Power
Power supply, type
5 V/3 A
5 V/6.3 A
Primary/secondary isolation
Yes
Yes
Potential separation
Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178
Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178
Protection class
Class II (without protective conductor)
Class II (without protective conductor)
CE mark
Yes
Yes
UL/CSA approval
Yes
Yes
UL/cUL (CSA) approval
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-recognized
(UL 60950, CSA C22.2 No. 60950), File E151273
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-recognize
d (UL 60950, CSA C22.2 No. 60950), File E151273
Explosion protection
ATEX (EX) II 3G Ex nA IIC T3; cCSAus
(CSA E60079, UL 60079), Class I, Div. 2,
Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T3; cCSAus
(CSA E60079, UL 60079), Class I, Div. 2,
Group ABCD, T4
FM approval
Yes
Yes
FM approval
Class I, Div. 2, Group ABCD, T4
Class I, Div. 2, Group ABCD, T4
CB approval
Yes
Yes
Marine approval
GL, ABS
GL, ABS
Degree of protection (EN 60529)
IP20
IP20
Emitted interference
EN 55022 Class B
EN 55022 Class B
Supply harmonics limitation
not applicable
not applicable
Noise immunity
EN 61000-6-2
EN 61000-6-2
Ambient temperature
• in operation
- Note
• on transport
• in storage
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
Humidity class according to EN 60721
Climate class 3K3, no condensation
Climate class 3K3, no condensation
screw-type terminals
screw-type terminals
• Output
• Auxiliary
L, N: 1 screw terminal each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
-
L, N: 1 screw terminal each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
-
Width of the housing
54 mm
0.072 m
Height of the housing
90 mm
90 mm
Depth of the housing
55 mm
55 mm
Installation width
54 mm
72 mm
Installation height
130 mm
130 mm
Weight, approx.
0.17 kg
0.25 kg
Product feature of the housing housing
for side-by-side mounting
Yes
Yes
Type of mounting wall mounting
No
No
Type of fixing cap rail mounting
Yes
Yes
Type of mounting S7-300 rail mounting
No
No
Installation
Snaps onto DIN rail EN 60715 35x7.5/15
Snaps onto DIN rail EN 60715 35x7.5/15
2
Safety
EMC
Operating data
Mechanics
Connection technology
Connections
• Supply input
Siemens ST 70 · 2013
2/29
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
2
Order No.
6EP1 321-1SH03
6EP1 322-1SH03
Product
LOGO!Power
LOGO!Power
Power supply, type
12 V/1.9 A
12 V/4.5 A
Input
1-phase AC or DC
1-phase AC or DC
Rated voltage value Vin rated
100 … 240 V
100 … 240 V
Voltage range
85 … 264 V
85 … 264 V
Input voltage at DC
110 … 300 V
110 … 300 V
Overvoltage resistance
2.3 × Vin rated, 1.3 ms
2.3 × Vin rated, 1.3 ms
Mains buffering at Iout rated, min.
40 ms
40 ms
Mains buffering
at Vin = 187 V
at Vin = 187 V
Rated line frequency
•1
•2
50 Hz
60 Hz
50 Hz
60 Hz
Rated line range
47 … 63 Hz
47 … 63 Hz
0.53 A
1.13 A
0.3 A
0.61 A
Switch-on current limiting (+25 °C),
max.
25 A
55 A
I²t, max.
0.8 A²·s
3 A²·s
Built-in incoming fuse
internal
internal
Protection in the mains power input
(IEC 898)
Recommended miniature circuit breaker: from 16 A,
characteristic B or from 10 A, characteristic C
Recommended miniature circuit breaker: from 16 A,
characteristic B or from 10 A, characteristic C
Output
Controlled, isolated DC voltage
Controlled, isolated DC voltage
Rated voltage Vout DC
12 V
12 V
Total tolerance, static ±
3%
3%
Static mains compensation, approx.
0.1 %
0.1 %
Static load balancing, approx.
1.5 %
1.5 %
Residual ripple peak-peak, max.
200 mV
200 mV
Residual ripple peak-peak, typ.
10 mV
10 mV
Spikes peak-peak, max.
(bandwidth: 20 MHz)
300 mV
300 mV
Spikes peak-peak, typ.
(bandwidth: 20 MHz)
20 mV
70 mV
Adjustment range
10.5 … 16.1 V
10.5 … 16.1 V
Product feature output voltage
adjustable
Yes
Yes
Output voltage setting
via potentiometer
via potentiometer
Status display
Green LED for output voltage OK
Green LED for output voltage OK
On/off behavior
No overshoot of Vout (soft start)
No overshoot of Vout (soft start)
Startup delay, max.
0.5 s
0.5 s
Voltage rise, typ.
10 ms
10 ms
Rated current value Iout rated
1.9 A
4.5 A
Current range
0 … 1.9 A
0 … 4.5 A
Note
1.9 A up to +55 °C, 1.3 A up to +70 °C
4.5 A up to +55 °C, 3.1 A up to +70 °C
delivered active power typ.
23 W
50 W
Parallel switching for enhanced
performance
Yes
Yes
Numbers of parallel switchable units
for enhanced performance
2
2
Efficiency at Vout rated, Iout rated,
approx.
80 %
85 %
Power loss at Vout rated, Iout rated,
approx.
5W
10 W
Input
Input current
• at nominal level of the input voltage
120 V nominal value
• at nominal level of the input voltage
230 V nominal value
Output
Efficiency
2/30
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
Order No.
6EP1 321-1SH03
6EP1 322-1SH03
Product
LOGO!Power
LOGO!Power
Power supply, type
12 V/1.9 A
12 V/4.5 A
Dynamic mains compensation
(Vin rated ±15 %), max.
0.2 %
0.2 %
Dynamic load smoothing
(Iout: 10/90/10 %), Uout ± typ.
3%
4%
Load step setting time 10 to 90%, typ.
1 ms
1 ms
Load step setting time 90 to 10%, typ.
1 ms
1 ms
Output overvoltage protection
Yes, according to EN 60950
Yes, according to EN 60950
Current limitation, typ.
2.8 A
5.8 A
Characteristic feature of the output
short-circuit protected
Yes
Yes
Short-circuit protection
Constant current characteristic
Constant current characteristic
Enduring short circuit current
Effective level maximum
3.6 A
7A
Overload/short-circuit indicator
-
-
Primary/secondary isolation
Yes
Yes
Potential separation
Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178
Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178
Protection class
Class II (without protective conductor)
Class II (without protective conductor)
CE mark
Yes
Yes
UL/CSA approval
Yes
Yes
UL/cUL (CSA) approval
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File E151273
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-recognized
(UL 60950, CSA C22.2 No. 60950), File E151273
Explosion protection
ATEX (EX) II 3G Ex nA IIC T3; cCSAus
(CSA E60079, UL 60079), Class I, Div. 2,
Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T3; cCSAus
(CSA E60079, UL 60079), Class I, Div. 2,
Group ABCD, T4
FM approval
Yes
Yes
FM approval
Class I, Div. 2, Group ABCD, T4
Class I, Div. 2, Group ABCD, T4
CB approval
Yes
Yes
Marine approval
GL, ABS
GL, ABS
Degree of protection (EN 60529)
IP20
IP20
Emitted interference
EN 55022 Class B
EN 55022 Class B
Supply harmonics limitation
not applicable
not applicable
Noise immunity
EN 61000-6-2
EN 61000-6-2
Ambient temperature
• in operation
- Note
• on transport
• in storage
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
Humidity class according to EN 60721
Climate class 3K3, no condensation
Climate class 3K3, no condensation
2
Closed-loop control
Protection and monitoring
Safety
EMC
Operating data
Siemens ST 70 · 2013
2/31
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
2
Order No.
6EP1 321-1SH03
6EP1 322-1SH03
Product
LOGO!Power
LOGO!Power
Power supply, type
12 V/1.9 A
12 V/4.5 A
screw-type terminals
screw-type terminals
• Output
• Auxiliary
L, N: 1 screw terminal each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
-
L, N: 1 screw terminal each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
-
Width of the housing
54 mm
72 mm
Height of the housing
90 mm
90 mm
Depth of the housing
55 mm
55 mm
Installation width
54 mm
72 mm
Installation height
130 mm
130 mm
Weight, approx.
0.17 kg
0.25 kg
Product feature of the housing housing
for side-by-side mounting
Yes
Yes
Type of mounting wall mounting
No
No
Type of fixing cap rail mounting
Yes
Yes
Type of mounting S7-300 rail mounting
No
No
Installation
Snaps onto DIN rail EN 60715 35x7.5/15
Snaps onto DIN rail EN 60715 35x7.5/15
Order No.
6EP1 351-1SH03
6EP1 352-1SH03
Product
LOGO!Power
LOGO!Power
Power supply, type
15 V/1.9 A
15 V/4 A
Input
1-phase AC or DC
1-phase AC or DC
Rated voltage value Vin rated
100 … 240 V
100 … 240 V
Voltage range
85 … 264 V
85 … 264 V
Input voltage at DC
110 … 300 V
110 … 300 V
Overvoltage resistance
2.3 × Vin rated, 1.3 ms
2.3 × Vin rated, 1.3 ms
Mains buffering at Iout rated, min.
40 ms
40 ms
Mains buffering
at Vin = 187 V
at Vin = 187 V
Rated line frequency
•1
•2
50 Hz
60 Hz
50 Hz
60 Hz
Rated line range
47 … 63 Hz
47 … 63 Hz
0.63 A
1.24 A
0.33 A
0.68 A
Switch-on current limiting (+25 °C),
max.
25 A
55 A
I²t, max.
0.8 A²·s
3 A²·s
Built-in incoming fuse
internal
internal
Protection in the mains power input
(IEC 898)
Recommended miniature circuit breaker: from 16 A,
characteristic B or from 10 A, characteristic C
Recommended miniature circuit breaker: from 16 A,
characteristic B or from 10 A, characteristic C
Mechanics
Connection technology
Connections
• Supply input
Input
Input current
• at nominal level of the input voltage
120 V nominal value
• at nominal level of the input voltage
230 V nominal value
2/32
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
Order No.
6EP1 351-1SH03
6EP1 352-1SH03
Product
LOGO!Power
LOGO!Power
Power supply, type
15 V/1.9 A
15 V/4 A
Output
Controlled, isolated DC voltage
Controlled, isolated DC voltage
Rated voltage Vout DC
15 V
15 V
Total tolerance, static ±
3%
3%
Static mains compensation, approx.
0.1 %
0.1 %
Static load balancing, approx.
1.5 %
1.5 %
Residual ripple peak-peak, max.
200 mV
200 mV
Residual ripple peak-peak, typ.
10 mV
10 mV
Spikes peak-peak, max.
(bandwidth: 20 MHz)
300 mV
300 mV
Spikes peak-peak, typ.
(bandwidth: 20 MHz)
30 mV
70 mV
Adjustment range
10.5 … 16.1 V
10.5 … 16.1 V
Product feature output voltage
adjustable
Yes
Yes
Output voltage setting
via potentiometer
via potentiometer
Status display
Green LED for output voltage OK
Green LED for output voltage OK
On/off behavior
No overshoot of Vout (soft start)
No overshoot of Vout (soft start)
Startup delay, max.
0.5 s
0.5 s
Voltage rise, typ.
15 ms
15 ms
Rated current value Iout rated
1.9 A
4A
Current range
0 … 1.9 A
0…4A
Note
1.9 A up to +55 °C, 1.3 A up to +70 °C
4 A up to +55 °C, 2.8 A up to +70 °C
delivered active power typ.
23 W
50 W
Parallel switching for enhanced
performance
Yes
Yes
Numbers of parallel switchable units
for enhanced performance
2
2
Efficiency at Vout rated, Iout rated,
approx.
81 %
85 %
Power loss at Vout rated, Iout rated,
approx.
7W
11 W
Dynamic mains compensation
(Vin rated ±15 %), max.
0.2 %
0.2 %
Dynamic load smoothing
(Iout: 10/90/10 %), Uout ± typ.
2.8 %
3%
Load step setting time 10 to 90%, typ.
1 ms
1 ms
Load step setting time 90 to 10%, typ.
1 ms
1 ms
Output overvoltage protection
Yes, according to EN 60950
Yes, according to EN 60950
Current limitation, typ.
2.7 A
5.7 A
Characteristic feature of the output
short-circuit protected
Yes
Yes
Short-circuit protection
Constant current characteristic
Constant current characteristic
Enduring short circuit current
Effective level maximum
3.6 A
7A
Overload/short-circuit indicator
-
-
2
Output
Efficiency
Closed-loop control
Protection and monitoring
Siemens ST 70 · 2013
2/33
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
2
Order No.
6EP1 351-1SH03
6EP1 352-1SH03
Product
LOGO!Power
LOGO!Power
Power supply, type
15 V/1.9 A
15 V/4 A
Primary/secondary isolation
Yes
Yes
Potential separation
Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178
Safety extra-low output voltage Uout acc. to EN 60950-1
and EN 50178
Protection class
Class II (without protective conductor)
Class II (without protective conductor)
CE mark
Yes
Yes
UL/CSA approval
Yes
Yes
UL/cUL (CSA) approval
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File E151273
cULus-listed (UL 508, CSA C22.2 No. 107.1),
File E197259; cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File E151273
Explosion protection
ATEX (EX) II 3G Ex nA IIC T3; cCSAus
(CSA E60079, UL 60079), Class I, Div. 2,
Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T3; cCSAus
(CSA E60079, UL 60079), Class I, Div. 2,
Group ABCD, T4
FM approval
Yes
Yes
FM approval
Class I, Div. 2, Group ABCD, T4
Class I, Div. 2, Group ABCD, T4
CB approval
Yes
Yes
Marine approval
GL, ABS
GL, ABS
Degree of protection (EN 60529)
IP20
IP20
Emitted interference
EN 55022 Class B
EN 55022 Class B
Supply harmonics limitation
Noise immunity
not applicable
EN 61000-6-2
not applicable
EN 61000-6-2
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
Climate class 3K3, no condensation
Climate class 3K3, no condensation
screw-type terminals
screw-type terminals
• Output
• Auxiliary
L, N: 1 screw terminal each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
-
L, N: 1 screw terminal each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals each for 0.5 ... 2.5 mm²
-
Width of the housing
54 mm
72 mm
Height of the housing
90 mm
90 mm
Depth of the housing
55 mm
55 mm
Installation width
54 mm
72 mm
Installation height
130 mm
130 mm
Weight, approx.
0.17 kg
0.25 kg
Product feature of the housing housing
for side-by-side mounting
Yes
Yes
Type of mounting wall mounting
No
No
Type of fixing cap rail mounting
Yes
Yes
Type of mounting S7-300 rail mounting
No
No
Installation
Snaps onto DIN rail EN 60715 35x7.5/15
Snaps onto DIN rail EN 60715 35x7.5/15
Safety
EMC
Operating data
Ambient temperature
• in operation
- Note
• on transport
• in storage
Humidity class according to
EN 60721
Mechanics
Connection technology
Connections
• Supply input
2/34
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
Order No.
6EP1 331-1SH03
6EP1 332-1SH43
6EP1 332-1SH52
Product
LOGO!Power
LOGO!Power
LOGO!Power
Power supply, type
24 V/1.3 A
24 V/2.5 A
24 V/4 A
Input
1-phase AC or DC
1-phase AC or DC
1-phase AC or DC
Rated voltage value Vin rated
100 … 240 V
100 … 240 V
100 … 240 V
Voltage range
85 … 264 V
85 … 264 V
85 … 264 V
Input voltage at DC
110 … 300 V
110 … 300 V
110 … 300 V
Overvoltage resistance
2.3 × Vin rated, 1.3 ms
2.3 × Vin rated, 1.3 ms
2.3 × Vin rated, 1.3 ms
Mains buffering at Iout rated, min.
0.04 s
40 ms
40 ms
Mains buffering
at Vin = 187 V
at Vin = 187 V
at Vin = 187 V
Rated line frequency
•1
•2
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
Rated line range
47 … 63 Hz
47 … 63 Hz
47 … 63 Hz
0.7 A
1.22 A
1.95 A
0.35 A
0.66 A
0.97 A
Switch-on current limiting (+25 °C),
max.
25 A
46 A
30 A
I²t, max.
0.8 A²·s
3 A²·s
2.5 A²·s
Built-in incoming fuse
internal
internal
internal
Protection in the mains power input
(IEC 898)
Recommended miniature circuit
breaker: from 16 A, characteristic B
or from 10 A, characteristic C
Recommended miniature circuit
breaker: from 16 A, characteristic B
or from 10 A, characteristic C
Recommended miniature circuit
breaker: from 16 A, characteristic B
or from 10 A, characteristic C
Output
Controlled, isolated DC voltage
Controlled, isolated DC voltage
Controlled, isolated DC voltage
Rated voltage Vout DC
24 V
24 V
24 V
Total tolerance, static ±
3%
3%
3%
Static mains compensation, approx.
0.1 %
0.1 %
0.1 %
Static load balancing, approx.
1.5 %
1.5 %
1.5 %
Residual ripple peak-peak, max.
0.2 V
200 mV
200 mV
Residual ripple peak-peak, typ.
0.01 V
10 mV
30 mV
Spikes peak-peak, max.
(bandwidth: 20 MHz)
0.3 V
300 mV
300 mV
Spikes peak-peak, typ.
(bandwidth: 20 MHz)
0.02 V
50 mV
60 mV
Adjustment range
22.2 … 26.4 V
22.2 … 26.4 V
22.2 … 26.4 V
Product feature output voltage
adjustable
Yes
Yes
Yes
Output voltage setting
via potentiometer
via potentiometer
via potentiometer
Status display
Green LED for output voltage OK
Green LED for output voltage OK
Green LED for output voltage OK
On/off behavior
No overshoot of Vout (soft start)
No overshoot of Vout (soft start)
No overshoot of Vout (soft start)
Startup delay, max.
0.5 s
500 ms
0.5 s
Voltage rise, typ.
0.015 s
10 ms
15 ms
Rated current value Iout rated
1.3 A
2.5 A
4A
Current range
0 … 1.3 A
0 … 2.5 A
0…4A
Note
1.3 A up to +55 °C, 0.9 A
up to +70 °C
2.5 A up to +55 °C, 1.7 A
up to +70 °C
4 A up to +55 °C, 2.8 A
up to +70 °C
delivered active power typ.
30 W
60 W
96 W
Parallel switching for enhanced
performance
Yes
Yes
Yes
Numbers of parallel switchable units
for enhanced performance
2
2
2
2
Input
Input current
• at nominal level of the input voltage
120 V nominal value
• at nominal level of the input voltage
230 V nominal value
Output
Siemens ST 70 · 2013
2/35
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
2
Order No.
6EP1 331-1SH03
6EP1 332-1SH43
6EP1 332-1SH52
Product
LOGO!Power
LOGO!Power
LOGO!Power
Power supply, type
24 V/1.3 A
24 V/2.5 A
24 V/4 A
Efficiency at Vout rated, Iout rated,
approx.
85 %
88 %
89 %
Power loss at Vout rated, Iout rated,
approx.
6W
8W
12 W
Dynamic mains compensation
(Vin rated ±15 %), max.
0.2 %
0.2 %
0.2 %
Dynamic load smoothing
(Iout: 10/90/10 %), Uout ± typ.
1%
2%
1.5 %
Load step setting time 10 to 90%, typ.
1 ms
1 ms
1 ms
Load step setting time 90 to 10%, typ.
1 ms
1 ms
1 ms
Output overvoltage protection
Yes, according to EN 60950
Yes, according to EN 60950
Yes, according to EN 60950
Current limitation, typ.
1.7 A
3.3 A
5.2 A
Characteristic feature of the output
short-circuit protected
Yes
Yes
Yes
Short-circuit protection
Constant current characteristic
Constant current characteristic
Constant current characteristic
Enduring short circuit current
Effective level maximum
2.4 A
4.8 A
7.9 A
Overload/short-circuit indicator
-
-
-
Primary/secondary isolation
Yes
Yes
Yes
Potential separation
Safety extra-low output voltage Uout
acc. to EN 60950-1 and EN 50178
Safety extra-low output voltage Uout
acc. to EN 60950-1 and EN 50178
Safety extra-low output voltage Uout
acc. to EN 60950-1 and EN 50178
Protection class
Class II (without protective conductor)
Class II (without protective conductor)
Class II (without protective conductor)
CE mark
Yes
Yes
Yes
UL/CSA approval
Yes
Yes
Yes
UL/cUL (CSA) approval
cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File E151273
cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File E151273
cULus-listed (UL 508, CSA C22.2
No. 107.1), File E197259;
cURus-recognized (UL 60950,
CSA C22.2 No. 60950), File E151273
Explosion protection
ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2, Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2, Group ABCD, T4
ATEX (EX) II 3G Ex nA IIC T3;
cCSAus (CSA E60079, UL 60079),
Class I, Div. 2, Group ABCD, T4
FM approval
Yes
Yes
Yes
FM approval
Class I, Div. 2, Group ABCD, T4
Class I, Div. 2, Group ABCD, T4
Class I, Div. 2, Group ABCD, T4
CB approval
Yes
Yes
Yes
Marine approval
GL, ABS, DNV, LRS (BV in process)
GL, ABS, DNV, LRS (BV in process)
GL, ABS, DNV, LRS (BV in process)
Degree of protection (EN 60529)
IP20
IP20
IP20
Emitted interference
EN 55022 Class B
EN 55022 Class B
EN 55022 Class B
Supply harmonics limitation
not applicable
not applicable
EN 61000-3-2
Noise immunity
EN 61000-6-2
EN 61000-6-2
EN 61000-6-2
Ambient temparature
• in operation
- Note
• on transport
• in storage
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
-20 … +70 °C
with natural convection
-40 … +85 °C
-40 … +85 °C
Humidity class according to EN 60721
Climate class 3K3, no condensation
Climate class 3K3, no condensation
Climate class 3K3, no condensation
Efficiency
Closed-loop control
Protection and monitoring
Safety
EMC
Operating data
2/36
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ Technical specifications (continued)
Order No.
6EP1 331-1SH03
6EP1 332-1SH43
6EP1 332-1SH52
Product
LOGO!Power
LOGO!Power
LOGO!Power
Power supply, type
24 V/1.3 A
24 V/2.5 A
24 V/4 A
screw-type terminals
screw-type terminals
screw-type terminals
• Auxiliary
L, N: 1 screw terminal
each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals
each for 0.5 ... 2.5 mm²
-
L, N: 1 screw terminal
each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals
each for 0.5 ... 2.5 mm²
-
L, N: 1 screw terminal
each for 0.5 ... 2.5 mm2
single-core/finely stranded
+, -: 2 screw terminals
each for 0.5 ... 2.5 mm²
-
Width of the housing
54 mm
72 mm
90 mm
Height of the housing
90 mm
90 mm
90 mm
Depth of the housing
55 mm
55 mm
55 mm
Installation width
54 mm
72 mm
90 mm
Installation height
130 mm
130 mm
130 mm
Weight, approx.
0.17 kg
0.25 kg
0.34 kg
Product feature of the housing housing
for side-by-side mounting
Yes
Yes
Yes
Type of mounting wall mounting
No
No
No
Type of fixing cap rail mounting
Yes
Yes
Yes
Type of mounting S7-300 rail mounting
No
No
No
Installation
Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
Snaps onto DIN rail
EN 60715 35x7.5/15
2
Mechanics
Connection technology
Connections
• Supply input
• Output
■ Ordering data
Order No.
Order No.
LOGO!Power 5 V
LOGO!Power 15 V
Stabilized power supply;
output: 5 V DC/3 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
6EP1 311-1SH03
Stabilized power supply;
output: 15 V DC/1.9 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
6EP1 351-1SH03
6EP1 311-1SH13
Stabilized power supply;
output: 15 V DC/4 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
6EP1 352-1SH03
LOGO!Power 12 V
LOGO!Power 24 V
Stabilized power supply;
output: 12 V DC/1.9 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
6EP1 321-1SH03
Stabilized power supply;
output: 24 V DC/1.3 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
6EP1 331-1SH03
6EP1 322-1SH03
Stabilized power supply;
output: 24 V DC/2.5 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
6EP1 332-1SH43
Stabilized power supply;
output: 24 V DC/4 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
6EP1 332-1SH52
Stabilized power supply;
output: 5 V DC/6.3 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
Stabilized power supply;
output: 12 V DC/4.5 A
• Input rated value:
100 … 240 V AC;
extended operating temperature
range: up to +70 °C
Siemens ST 70 · 2013
2/37
© Siemens AG 2013
LOGO! logic module
LOGO!Power
LOGO!Power
■ More information
2
In addition to various power supply product lines, the perfectly
coordinated complete SITOP range offers a unique range of
add-on modules with which the 24 V power supply can be
additionally protected against interference on the primary and
secondary side – right up to all-round protection:
• Redundancy module for setting up a redundant power supply
• Uninterruptible 24 V power supplies with batteries or
maintenace-free capacitors for continued operation in the
event of power failure
• Selectivity modules for electronic protection of 24 V branches
from overload and short-circuit
You can find more information in Catalog KT 10.1 and in the
Internet at
www.siemens.com/sitop
Select the appropriate power supply quickly and easily with the
SITOP Selection Tool:
www.siemens.com/sitop-selection-tool
2/38
Siemens ST 70 · 2013
© Siemens AG 2013
LOGO! logic module
LOGO!Power
SIPLUS LOGO!Power
■ Overview
■ Ordering data
Note:
SIPLUS LOGO!Power 24 V 1.3 A
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.
(extended temperature range and
medial exposure)
Order No.
6AG1 331-1SH03-7AA0
2
Input 100 ... 240 V AC
Output 24 V DC, 1.3 A
SIPLUS LOGO!Power 1.3 A
Order number
6AG1 331-1SH03-7AA0
Order number based on
6EP1 331-1SH03
Ambient temperature range
-25 °C to +70 °C
Conformal coating
Coating of the printed circuit boards
and the electronic components
Technical data
The technical data of the standard
product applies except for the
ambient conditions.
Ambient conditions
Relative humidity
100%, condensation/frost permissible. No commissioning if condensation present.
Biologically active substances,
compliance with EN 60721-3-3
Class 3B2 mold spores, fungal
spores (excluding fauna). The supplied plug covers must remain in
place over the unused interfaces
during operation!
Chemically active substances,
compliance with EN 60721-3-3
Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree
of severity 3). The supplied plug
covers must remain in place over
the unused interfaces during operation!
Mechanically active substances,
compliance with EN 60721-3-3
Class 3S4 incl. sand, dust.
The supplied plug covers must
remain in place over the unused
interfaces during operation!
Air pressure (depending on the
highest positive temperature range
specified)
1080 ... 795 hPa
(-1000 ... +2000 m)
see ambient temperature range
795 ... 658 hPa
(+2000 ... +3500 m)
derating 10 K
658 ... 540 hPa
(+3500 ... +5000 m)
derating 20 K
For technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-extreme
Siemens ST 70 · 2013
2/39
© Siemens AG 2013
LOGO! logic module
LOGO!Contact
LOGO!Contact
■ Overview
■ Technical specifications
2
Weight
Weight, approx.
■ Ordering data
6ED1 0574CA00-0AA0
6ED1 0574EA00-0AA0
160 g
160 g
Order No.
LOGO!Contact
Switching module for direct
switching of resistive loads
up to 20 A and motors up to 4 kW
• Switching module for the direct switching of resistive loads
and motors
2/40
Siemens ST 70 · 2013
Switching voltage 24 V
6ED1 057-4CA00-0AA0
Switching voltage 230 V
6ED1 057-4EA00-0AA0
© Siemens AG 2013
LOGO! logic module
LOGO! Software
LOGO! Software
■ Overview
■ Ordering data
LOGO!Soft Comfort V7.0
Order No.
6ED1 058-0BA02-0YA1
For programming on the PC in
LAD/FBD; executes on Windows 7
(32/64 bit), VISTA, XP, NT4.0, 2000,
98SE, Linux and MAC OSX;
on CD-ROM
LOGO!Soft Comfort V7.0 upgrade
2
6ED1 058-0CA02-0YE1
Upgrade from V1.0 to V7.0
• The user-friendly software for creating control programs
on a PC
• Creation of control programs in Function Block Diagram (FBD)
or Ladder Diagram (LAD)
• Plus testing, simulation, online testing and archiving of control
programs
• Professional documentation via numerous comment and print
functions
Minimum system requirements
Windows 98 SE, NT 4.0, ME, 2000, XP (32 bit),
Vista or 7 (32/64 bit)
• PC Pentium.
• 90 MB free disk capacity.
• 64 MB RAM.
• SVGA graphics card with minimum resolution 800x600
(256 colors).
Mac OS X
• Mac OS X 10.4 with J2SE 1.5.0
• Mac OS X 10.5 with J2SE 1.6.0
• PowerMac G3, G4, G4 Cube, IMac, PowerBook G3, G4 or
iBook.
Linux
• Tested with SUSE Linux 10 SP2, kernel 2.6.16
• Runs on all Linux distributions on which the Java 2 SDK
Version 1.3.1 runs.
• Please refer to your relevant Linux distribution for the
necessary hardware requirements.
Siemens ST 70 · 2013
2/41
© Siemens AG 2013
LOGO! logic module
Notes
2
2/42
Siemens ST 70 · 2013
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement