KANOMAX USA, INC. 219 US Hwy. 206 PO Box 372 Andover, NJ 07821 Tel: 1-800-247-8887, 1-973-786-6386 (from outside of US) Fax: 1-973-786-7586 URL: www.kanomax-usa.com 2nd Edition Rev.2 Kanomax Group Since our inception more than 50 years ago, Kanomax has been the most promising manufacturer of a broad range of precision measuring instruments for fluid mechanics research, environmental, aerosol research, particles measurement, and customized system applications. As a company that prides itself in technology, product quality, and service, we have been enjoying an unsurpassed reputation in the Japanese industrial and academic fields. Japanese customer demand for high quality has driven us to produce the finest manufactured products in the industry. We are pleased to introduce our quality products to the global market. To further benefit our customers worldwide, we have launched our global operations aiming to introduce our dependable technology and to provide our wide range of measuring solutions and services. Kanomax USA, Inc. (NJ) Kanomax Holdings, Inc. (NY) Kanomax Japan, Inc. Shenyang Kanomax Instrument Co., Ltd. (China) Kanomax FEASibility Kanomax makes your idea feasible and realizes your needs. Environmental Measurement Instruments Fluid Measurement Instruments Having established worldwide brand recognition and product loyalty, Kanomax Fluid Measurement Instruments have become the measurement standard in Japan. Our Fluid Velocity Systems have wide-ranging industrial applications to include Elimination of Locomotive Wheel Noise, Research to Increasing Energy Efficiency, Architectural Research and Development, Civil Engineering, Chemistry, and Medical Science Research to name a few. has developed demand for improved monitoring and control of air temperature, humidity, flow and particulates. Kanomax produces a number of Air Measurement and Control Instruments currently utilized by industry professionals. These devices are vital tools for maintaining Constant Air Quality and Comfort in critical locations that include public and private offices, factories, and medical facilities. Kanomax Anemometers currently enjoy a 67.9% market share among top 10 Japanese subcontractors. Aerosol Measurement Instruments Kanomax Ever increasing public awareness for air quality is driving the Particle System Application Measurement Kanomax has developed custom Wind Tunnel, Technologies to address a variety of applications from Environmental Test and Performance Test systems for a Semiconductor Production Facilities requiring rigorous air variety of areas that include Aviation, Environmental cleanliness to general office work environments. Our Assessment, and Automotive. As an example, during the Particle Measurement Technology is generally divided into development of an intercontinental rapid transit scramjet three areas, Environmental Comfort Monitoring, engine, Kanomax tested flame stabilization, air inlet shape, Cleanroom Environment Monitoring, and Aerosol Research and many other effects using Kanomax supersonic wind Instruments. tunnels. Customer Services Kanomax fully understands service to be an essential part of the total solution provided to our valued customers. Having already established a worldwide service network, we continuously strive to improve our support services. NIST (National Institute of Standards and Technology) Traceable Calibration Services Our Calibration Laboratory in New Jersey maintains the longest and most accurate wind tunnel of its kind. Kanomax provides the highest quality of service available with a quick turnaround time. Our service specialists are well trained and will calibrate your instruments to the highest standards. We recommend that all instruments be calibrated on an annual basis. Kanomax Global Calibration Facility Kanomax’s global (Japan and US) calibration facilities are directly traceable to the national standards and ensure the highest precision measurements for our valued customers. We are fully committed to providing the best calibration services possible utilizing our global facilities. Kanomax Anemometer Calibration Facility Calibration Facility Temperature Variable Wind Tunnel Low Velocity Wind Tunnel High Velocity Wind Tunnel High Temperature Wind Tunnel Open Jet Wind Tunnel Humidity Calibrator Pressure Generator Type GÖTTINGEN (closed-circuit) EIFFEL (open-circuit) GÖTTINGEN (closed-circuit) GÖTTINGEN (closed-circuit) Centrifugal fan a) Two temperature type b) shunt type Pump type Specifications 59 to 9840fpm (0.3 to 50m/s) 41 to 176ºF (5 to 80ºC) 10 to 492fpm (0.05 to 2.5m/s) 590 to 9840fpm (3 to 50m/s) Room temperature to 752ºF (400ºC) 20 to 9840fpm (0.1 to 50m/s) 50 to 6000fpm (0.25 to 30.5m/s) a) 3 to 100%, 41 to 104ºF (5 to 40ºC) b) 0 to 100%, 41 to 140ºF (5 to 60ºC) ±0 to 10kPA Applications Temperature compensating calibration Low velocity range air velocity calibration High velocity range air velocity calibration High temperature range air velocity calibration Anemometers and Pitot tubes calibration Humidity calibration Pressure calibration Standard Particle Generator Open Jet Wind Tunnel Indoor Environment Airconditioning Equipment Hightemperature Environment 6815 6813 6812 1570 1560 ○ ○ ○ Air-condition and environmental measurement in buildings and factories ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Air-conditioning capacity test and maintenance check ○ ○ ○ ○ ○ ○ ○ ○ ○ Air velocity measurement in cleanroom ○ ○ ○ ○ ○ ○ ○ ○ Performance check for HEPA filter, etc. ○ ○ ○ ○ ○ Stack gas and combustion air measurement ○ for incinerator, electric furnace, boiler, etc. Hot air measurement for drying air, sterilization, etc Product performance check for cooling efficiency, drying efficiency, etc. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Air velocity control for blowers Multipoint measurement 1550 ○ ○ ○ ○ ○ ○ ○ ○ ○ (e.g. inside PCs) for cooling efficiency, etc. Automotive 6312 6162 6113 A543 A542 A541 A533 A531 Air environmental measurement in residence and office buildings Air velocity measurement in tight quarters Inspection, Control A031 Application A004 Area A003 Anemometers Selection Guide Automobile velocity measurement ○ ○ ○ ○ ○ ○ Air velocity measurement for engine compartment and vehicle interior ○ ○ ○ ○ ○ ○ Air velocity distribution measurement in indoor and inside ducts ○ ○ ○ ○ ○ ○ Air velocity monitoring in cleanroom and indoor ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Solution Technologies for Automotive R&D R&D competition is increasingly keen in the modern day automobile industry. Kanomax continually monitors trends and user needs of collective automobile technologies. Kanomax designs and produces testing equipment utilizing state of the art technologies. We offer customized engineering systems and products, applying our many competitive technologies. These include fluid mechanics research instruments, particle measurement devices, optical measurement systems and control technology for the automobile, aeronautics, shipbuilding, and architectural industries. Kanomax optimizes system applications to meet each customer’s individual needs, drawing on our solid product knowledge, years of experience and many successful engagements. CONTENTS Velocity, Air Temperature, 1 Air Relative Humidity, Differential Pressure 1 2 Thermohygrometer 13 3 IAQ Monitor, Gas Monitor 14 4 Particle / Dust Monitor 18 5 Cleanroom Facility Monitoring 23 6 Aerosol Research Instrumentation 27 7 Fluid Mechanics Research Instrumentation 29 8 R & D / Test Instrument and System 30 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Anemomaster Model A004 Palm-Size Hot-Wire Anemometer NIST Traceable HVAC Testing IAQ Investigation Industrial Hygiene Cleanrooms Features: • Probe Compatibility feature allows utilization of a spare probe • Detachable probe • Compact, light-weight, and affordable • Simple operation • Wide ranges of measurement • Built-in temperature compensation circuit Benefits: • Palm-size and feather-weight main body is hardly noticeable • Accuracy of +/- 3% is maintained to suit your needs • Soft keys and large display make it a breeze to conduct measurement • Temperature compensation maintains accuracy at any temperature in the range Specifications Model A004 Range Accuracy Air Velocity Response Time Resolution 20 to 3940 fpm (0.10 to 20.0m/s) +/-3% of reading or +/-3 fpm (+/-0.015m/s) whichever is greater Less than 1second at 196 fpm (1m/sec), 90% response 0 to 9.99 m/sec: 0.01 m/sec (minimum) 10.0 to 20.0 m/sec: 0.1 m/sec Range Air Accuracy Temperature Response Time 32 - 122ºF (0-50ºC) +/-0.2ºF (1ºC) Less than 30 seconds at 196 fpm (1 m/sec), 90% response Resolution 1ºF (0.1ºC) 4 x 1.5V AA cells Mn battery, alkaline battery, or Ni-Cd battery Power Supply (An appropriate charger to be used for the Ni-Cd battery) Battery Life Approx. 4 hrs. Continuous at air velocity 196 fpm (1 m/s) with Mn batteries Operating Main Unit 41 to 104ºF (5 to 40ºC) Environment Probe 32 to 122ºF (0 to 50ºC) Storage Environment 14-122ºF (-10 to 50ºC) Probe: approx. 0.24" or 0.40" (6 or 10 mm) in diameter x 7.9" (200 mm) in length Dimensions Probe cable: 0.13" (3.3 mm) in diameter x 59" (1500 mm) in length Main body: 2.4" (60 mm) x 4.7" (120 mm) x 1.2" (30 mm) Weight Approx. 0.4lbs (180g) including batteries Standard Kit Optional Accessories Operation Manual, AA Batteries Spare Probe, Extension Rod (Telescopic 6.5" - 35.8" / 166mm to 909mm) 1 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Anemomaster Model A031 Series NIST Traceable HVAC Testing IAQ Investigations Filter Face Velocity Measurements Cleanroom Studies Industrial Hygiene Features: • Single probe capable of measuring air velocity and temperature simultaneously • Built-in memory allows storage of measured data • Highly- visible LCD is capable of displaying air velocity and temperature simultaneously • RS232 and Analog (option) outputs are available Benefits: • Data can be reviewed on-screen, printed, or downloaded to a computer • Articulating probe for various applications • Etched length increments on the telescopic probe make duct traverse measurements easier • Telescopic probe for hard-to-reach areas and in-duct measurements Specifications Air Velocity Range Accuracy Resolution 20-6000fpm (0.10-30.0m/s) +/-2% of reading or +/-3fpm whichever is greater (+/-2% of reading or +/-0.015m/s whichever is greater) 1fpm (0.01m/s from 0 to 9.99m/s, 0.1m/s from 10.0 to 30.3m/s) 3 Volumetric Flowrate Temperature Differential Pressure (Option) Output Range Accuracy Resolution Range Accuracy Resolution Digital Analog Power Supply Data Storage Probe Accessories Options Straight Probe Model A031/A041 Articulating Probe Model A034/A044 At 20 fpm: 9031 ft3/min, at 6000 fpm: 2,709,360 ft /min 3 3 (At 0.1m/s: 2,341m /s, At 30 m/s: 702,270 m /s) -4 to 140.0 ºF (-20 to 60.0ºC) +/-1ºF (+/-0.3ºC) 0.1ºF (0.1ºC) -5.00 to + 5.00kPa +/- (3% of reading + 0.01)kPa 0.01kPa RS 232C (Baud rate 4800, 9600, 19200 and 38400 bps) DC 0-3 V (Select from Air Velocity, Air Temperature and Pressure) 6 x 1.5V AA batteries (AC adaptor: AC90-240V/Optional) Timed and multipoint average calculation. Total of 800 data for Velocity and Temperature / Volumetric Flowrate and Temperature / Pressure Length: 39.4 in. (100 cm)- Telescopic / Diameter of Tip: 0.236 in. (6.0mm), Diameter of Base: 0.472 in. (12.0 mm) Length: 39.4 in. (100 cm)- Telescopic / Diameter of Tip: 0.236 in. (6.0mm), Diameter of Base: 0.472 in. (12.0 mm) Articulating section length: 3.543 in. (90.0 mm) Carrying case, Operation manual, 6 x AA Batteries, RS-232C cable, Software (for Windows), AC adaptor Analog output, Printer, AC adaptor (for Printer) 2 Climomaster Series Air Velocity, Air Temperature, Relative Humidity, Differential Pressure NIST Traceable Multi-Function Thermal Anemometer Ventilation Testing Laboratory Control Cleanrooms IAQ Investigation Industrial Hygiene Quality Control A531 A541 A542 A533 Features: • Probe Compatibility feature allows utilization of a spare probe • Detachable probe allows for easy replacement, and for compatibility with multi-function thermo anemometers • Automatic Flow Rate Calculation function • RS232C terminal for data logging • Stores up to 1500 measurement data • Differential Pressure available as an option A543 Benefits: • If you have more than one unit, detachable probe allows you to share the main unit or the probe. • Gives automatic flow rate readings by registering duct sizes (up to 25 duct sizes). • Well designed software allows you to access the data instantly. • You can store the data or upload it to your PC via RS232C cable and software (both optional) Specifications Model Air Velocity Range Air Temperature Range Relative Humidity Range Differential Pressure (Option) Accuracy Output Digital Analog Power Supply Battery Life Operating Main Unit Environment Probe Storage Environment Weight Standard Kit Optional Accessories A531 A541 A542 A533 A543 20 to 6000fpm (0.10 to 30.0m/s) 10 to 1000fpm (0.05 to 5.00m/s) 32.0 to 140.0ºF (0.0 to 60.0ºC) 2.0 to 98.0%RH -2.0 to 98.0%RH --5.00 to +5.00kPa Velocity: +/-2% of reading or +/-3fpm (+/-0.015m/s) whichever is greater Air Temperature: +/- 1 ºF (+/-0.5 ºC) Relative Humidity: +/-2.0%RH from 2 to 80%RH, +/-3%RH from 80 to 98%RH Differential Pressure: +/- (3% of reading +0.01)kPa RS-232C (Baud Rate 4800, 9600, 19200 and 39400bps) DC0-1V (Select from Air Velocity, Air Temperature, Relative Humidity and Pressure) 6 x 1.5V AA Batteries, AC Adapter (Optional): AC100-240V Approx. 10hrs. Continuous at 984fpm (5m/s), 68ºF (20ºC) with alkaline batteries 41 to 104ºF (5 to 40ºC) 32 to 140ºF (0 to 60ºC) 41-104ºF (5 to 40ºC) Approx. 0.9lbs (400g) Carrying Case, Operation Manual, AA Batteries, Probe Cable Spare Probe, Analog Output, Pressure Sensor, Extension Rod, Printer, Printer Cable, Communication Cable, Software (for Windows), AC Adapter: AC100-240V 50/60Hz Selection Guide Model A531 A541 A542 A533 A543 Measuring Range 20 - 6,000 fpm 20 - 6,000 fpm 20 - 6,000 fpm 10 - 1,000 fpm 10 - 1,000 fpm Probe Type Rod Rod Needle Spherical Spherical Directivity Mono Mono Omni Omni Omni 3 Velocity & Temp. ○ ○ ○ ○ ○ Relative Humidity ○ × × ○ × Air Velocity, Air Temperature Relative Humidity, Differential Pressure Anemomaster Model 6812, 6813, 6815 Rotating Vane Digital Anemometer NIST Traceable HVAC Testing IAQ Investigations Industrial Hygiene Cleanroom Testing Features: Display switchable in m/s (MPS) or ft/min (FPM) for air velocity and cubic ft/min (CFM) or cubic meter/hr (CMH) for calculated air volume flow. Very high accuracy due to use of microprocessor Digital memory for maximum and minimum values Average measurements over two or sixteen seconds for air velocity Display hold for easy reading of measurements Long battery life Specifications Model Air Velocity Probe AP275 Probe AP100 Accuracy Resolution Air Volume Flow Temperature 6812 Air Vel. Probe Optional Temp Probe Accuracy Resolution Range Relative Accuracy Humidity Resolution Display Operating Temperature 6813 40 to 7800 FPM (0.2 to 40 m/s) 60 to 6800 FPM (0.3 to 35 m/s) ±1.0% of Reading ±1 digit 1 FPM or 0.01 m/s - 0.0 to 9999 CFM(ft3/min) / 0.0 to 9999 m3/hr -22 to 212 F (-30 to 100C) -139 to 392 F (-95 to 200C) ±0.3℃ ±0.2% of Reading in ℃ - Dimensions Standard Accessories 0.1 F or 0.1℃ (1 F below -99.9 F) 5.0 to 95.0 %RH ±2.0 %RH 0.1 %RH 0.5 inch LCD, 4 digits with LED Backlight Instrument: 32 to 125F (0 to 50C) Probe: -4 to 212F (-20 to 100C) Power Supply Operating Time (Battery) Instrument Probe AP275 Probe AP100 RH/Temp Probe 6815 3 AA Alkaline Batteries Approximately 150 hours W 3.2 x D 1.5 x H 6.5 inches (8.2 x 3.8 x 16.5 cm) 2.75 inch diameter - 1.00 inch diameter 6 inch x 1 inch diameter 1 x Rotating Vane Probe Head, your choice of AP275 or AP100 HTP 201 combination RH / Temp Probe (available for 6815) Extension Rod w/ Handle Grip, Flexible Rod 3 x AA 1.5V Alkaline Batteries, Operation Manual, Carrying Case ※Please contact us for Standard Kit & Optional Accessories for those products 4 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Anemomaster Model 6113, 6114 Multi-Function Thermal Anemometer NIST Traceable Built-in Printer (Model 6113) Probe Compatibility RS-232C Terminal Features: • Probe Compatibility feature allows utilization of a spare probe • Simultaneously measures air velocity, temperature, and pressure measurements • Large, easy-to-read LCD Benefits: • Quick printing of measurements at site • Simple operation with buttons for printing and calculation • Easily keeps record of measurements • Suitable for measurements inside ducts Specifications Air Velocity Range Air Temperature Range Pressure (Option) Range Measuring Functions 32 to 212ºF (0 to 100ºC) +/-2.0ºF (1.0ºC) -5.00 to +5.00kPa Accuracy +/-(3% of reading +0.01)kPa Settings Display hold, time constant setting (1, 5, or 10 sec.), remaining battery life (5 steps), measuring unit setting (m/s, fpm, Celsius, Fahrenheit, kPa). Data Storage Calculation Instantaneous storage, average (over 60 sec. max.), Storage 100 max. Maximum and minimum values, averaging, raw data display Calendar function, air velocity bar graph display. Digital Output RS-232C (4800, 9600, 19200, 38400bps) for communication with PC. Printer Output Printing calculation results and measurements. Analog Output (Option) DC 0 to 1V (1ch. Selected from air velocity, temp. and pressure) Power Supply 6 × 1.5 volt C cells (Mn, alkaline, or Ni-Cd) Battery Life Operating Environment +/-(3% of reading +20fpm (0.1m/s)) Accuracy Display Outputs 20 to 9840 fpm (0.10 to 50.0 m/s) Accuracy 10 hours continuous operation (with alkaline batteries, at 5m/s, 20C, without printer use) Main Body 41 to 104ºF (5 to 40ºC) Probe 32 to 212ºF (0 to 100ºC) Storage Environment 41 to 104ºF (5 to 40ºC) Weight (including batteries) Approx. 2.2 lbs. (Approx. 1000 g) Dimensions Standard Kit Optional Accessories 7.9” x 5.9” x 3.9” (200 x 150 x 100mm) 1 x operation manual, 6 x 1.5V Mn C cells, 1 x probe with 2-meter (6.6-feet) cable, 1 x extension rod, 1 x shoulder strap Spare Probe, Analog Output, Pressure Measurement, Printer Paper, Communication Cable, Data Management Software (for Windows), AC Adapter 5 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Anemomaster Model 6162 NIST Traceable Middle and High Temperature Anemomaster Probe Model 0203 (Middle temp. Up to 392ºF (200ºC)) Model 0204 (High temp. Up to 932ºF (500ºC)) Features: • Simultaneous display of air velocity and temperature • Improved response time by the addition of secondary temperature compensation circuit • Easy review of time history by graphic display • Memory function of maximum 999 separate measurement data • Built-in RS-232 C serial interface for connection to PC. Analog output and remote control terminal also equipped • Probe Compatibility feature allows you to change the probe easily Specifications Model Probe Model 0203 (for middle temp.) 32 – 392F (0 – 200ºC) Measuring Range Probe Model 0204 (for high temp.) 32 – 752F (0 – 400ºC) 40 – 9840fpm (0.2 – 50m/s): 32 – 212ºF (0 – 100ºC) 80 –9840fpm (0.4 – 50m/s): 212 – 392ºF (100 – 200ºC ) -- 138 – 9840fpm (0.7 – 50m/s): 392 – 572ºF (200 – 300ºC) -- 197 – 9840fpm (1.0 – 50m/s): 572 – 752ºF (300 – 400ºC) Measuring Accuracy Air velocity: +/-3%F.S. Air temperature: +/-(1%rdg+1ºC) Temp. Compensation Less than 984fpm (5m/s): +/-10%F.S. Less than 984fpm (5m/s): +/-15%F.S. Accuracy (Air Velocity) 984fpm(5m/s) to 9,840fpm(50m/s): +/-6%F.S. 984fpm(5m/s) to 9,840fpm(50m/s): +/-10%F.S. Heat-resistance Teflon coating (Probe side): 392ºF (200ºC) of Cable Vinyl code (Extension cable): 176ºF (80ºC) Length of Cable Extension Rod (Option) Probe Dimensions Display Input/output Terminal Power Supply Teflon coating 4.9ft (1.5m) Teflon coating 7.5ft (2.3m) Vinyl code 16.4ft (5m) Vinyl code 32.8 (10m) 0.65”(MAX)x31.5” (16.5x800mm) 0.87”(MAX)x81.5” (22x2070mm) Dimension: φ0.43”x8.2” (11x208mm) Dimension: φ0.43”x39.4” (11x1000mm) Digital (simultaneous display of air velocity and temperature) Remote terminal: START/STOP key Analog output terminal: Output voltage 0 – 1 V, Output impedance 47 Ω Digital output terminal: RS-232C (serial interface) Dry battery drive: US type (1.5V x 6 pcs = 9V), Alkaline battery, Mn battery AC adapter: 12.5V, 450mA (AC100V +/- 10%, 50/60Hz) Operating Temp. 41 – 104ºF (5 – 40ºC) Battery Life Dimensions Weight Approx. 8 hours 8.7” x 3.3” x 5.9” 220 x 85 x 150 mm Main body: Approx. 4.0lbs (1.8kg), Probe Model 0203: 7.1oz(200g), Model 0204: 17.6oz (500g) 6 4 Channel Anemomaster Model 1570 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure NIST Traceable Product Efficiency Control Ventilation Testing IAQ Investigation Cleanroom Features: • 4CH simultaneous measurement in a compact body. • Wide probe selection available for various applications. • Capable of taking measurements at high-time-resolution (0.1 sec) • RS232C terminal for data logging. Benefits: • Each channel display can be easily switched over by the touch of a button • Probe compatibility saves your downtime and shipping cost • Windows software gives you simultaneous measurement on air velocity and flow rate • Measurement data saved in text format for easy processing using other software such as Excel Main Body Specifications: Display Data Transfer Software Function Output LCD display Transfers data of all channels Burst Mode Channel Mode Transfers data of specific channel only Instant Mode Displays instantaneous values every specified sampling time Average Mode Displays average values of a specified sampling time Digital Analog RS 232C (Baud rate 9600bps fixed) 0-5 V Main Body Operation Temperature 41-104ºF (5-40ºC) External Dimensions 7.8” x 10.2” x 2.8” (200 x 260 x 70mm) Weight Power Supply Standard Kit 5.7 lbs (Approx. 2.6 kg) AC 85V – 276V 50Hz/60Hz RS-232 cable, Power cable, 2xFuse, Data Processing Software Probe Specifications: Model Measuring Range & Accuracy Temperature Compensation Response Time (1 m/s, 90% response) 0962-00 / 0963-00 0964-01 / 0964-02 0965-00/01/03/04/07/08 20-1000fpm: +/-20fpm (0.1-4.99m/s: +/-0.1m/s) 1000-2000fpm: +/-40fpm (5.00-9.99m/s: +/-0.2m/s) 2000-5000fpm: +/-100fpm (10.0-24.9m/s: +/-0.5m/s) 5000-10000fpm:m+/-200fpm (25.0-50.0m/s: +/-1.0m/s) 20-1000fpm: +/-30fpm (0.1-4.99m/s: +/-0.15m/s) 1000-2000fpm: +/-60fpm (5.00-9.99m/s: +/-0.3m/s) 2000-5000fpm: +/-150fpm (10.0-24.9m/s: +/-0.75m/s) 5000-10000fpm:m+/-300fpm (25.0-50.0m/s: +/-1.5m/s) 20-1000fpm: +/-30fpm (0.1-4.99m/s: +/-0.15m/s) 1000-2000fpm: +/-60fpm (5.00-9.99m/s: +/-0.3m/s) 2000-5000fpm: +/-120fpm (10.0-25.0m/s: +/-0.6m/s) 41 – 176ºF (5 – 80ºC) Approx. 1 sec Approx. 3 sec 7 Approx. 7 sec Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Multi-Channel Anemomaster Model 1550 & 1560 NIST Traceable Real-Time Air Quality Monitoring System 1550 1560 Features: • Main Unit Features: One unit of Model 1550 has 64 Channels for air velocity. • For a larger system, connect up to 5 units in a cascade and add a computer for control. • Up to 320 channels of measuring points. • Flexibility in system configuration means greater freedom, simplicity, and efficiency in measurement. Specifications: Model 1550 1560 LCD (with backlight) Simultaneously displays on a module basis Display MAN: Select modules by operating the UP/DOWN switches AUTO: Automatically selects modules every 2 seconds to display data Burst Mode: Transfers data of all channels at high speed Functions Channel Mode: Transfers data of the specific channel only Data Selection: Outputs instantaneous values every specified sampling time, and outputs the average Data transfer: RS232C (standard), Extended RS232C (optional) GP-IB (optional) Interface Baud Rate: 300, 600, 1200, 2400, 4800, 9600, 19200bps (selectable) Printer output: Centronics Dimensions 16.9” x 19.6” x 5.5” (430 x 500 x 140 mm) 8.9” x 12.8” x 5.5” (226 x 325 x 140mm) Weight Approx. 22lbs (Approx. 10kg) Approx. 11lbs (Approx. 5kg) 8 Probes: Velocity & Temperature Velocity Model 0963-00 A-200 (Rod) V: 20 – 9840 fpm (0.1 – 50 m/s) Model 0963-21 A-200 Rod V: 20 – 9840 fpm (0.1 – 50 m/s) T: 32 – 212ºF (0 – 100ºC) Model 0962-00 Caramel V: 20 – 9840 fpm (0.1 – 50 m/s) Model 0962-21 Caramel V: 20 – 9840 fpm (0.1 – 50 m/s) T: 32 – 212ºF (0 – 100ºC) Model 0965-21 Spherical V: 20 – 4920 fpm (0.1 – 25 m/s) T: 32 – 212ºF (0 – 100ºC) Model 0965-00/01 Spherical V: 20 – 4,920 fpm (0.1 – 25 m/s) Model 0963-31 A-200 Rod V: 20 – 9840 fpm (0.1 – 50 m/s) T: 32 – 140ºF (0 – 60ºC), H: 5 – 95%RH L-Shaped (04) Model 0965-03/04 Miniature with Built-in Temperature Compensation V: 20 – 4920 fpm (0.1 – 25 m/s) I-Shaped (03) Velocity, Temperature, & Humidity L-Shaped (08) Model 0965-07/08 Miniature with Independent Temperature Compensation V: 20 – 4920 fpm (0.1 – 25 m/s) I-Shaped (07) Model 0965-31 Spherical V: 20 – 9840 fpm (0.1 – 50 m/s) T: 32 – 140ºF (0 – 60ºC), H: 5 – 95%RH Model 0964-01/02 Omni-directional V: 20 – 4920 fpm (0.1 – 25 m/s) Modules Model 1504 V Module 4 ch. Model 1511 VT Module 2 ch. Model 1512 TVH Module 1 ch. Model 1503 Pressure Module 2 ch. Model 1510 Analog Output Module Module Features: Five types of modules add more freedom to system configuration. • 4-channel air velocity module Model 1504 • 2-channel air velocity and temperature module Model 1511 • 1-channel air velocity, temperature, and humidity module Model 1512 • Static pressure module Model 1503 • Analog output module Model 1510 * Combine these modules and design a multi-channel system freely. More modules can be added whenever necessary 9 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Tabmaster Features: • • • • • • • • • • • • • Designed For Maximum Contractor Productivity 30 hour battery life Largest selection of hoods in the industry Displays air volume flow, velocity and temperature in metric or imperial measurements Self-averaging, measuring sensor complies with ISO 3966 Detachable meter can be used with optional 4” rotating vane kit for face velocity measurements Optional 4” vane head and Aircone Hood Kit Display indicates supply or exhaust flow-Memory, avg/max/min/sum, communication to Windows® via RS232 serial port Folding hood frame, no onsite assembly required 4 handle locations available (2 handles included) Measurements down to 50 cfm without a low flow screen Durable rubber grill seal outlasts typical foam seals. True ambient readout. Displays flow in actual or standard CFM with onboard conversion via user input of temperature and pressure 2' x 2' 16" x 16" 2' x 4' 610 x 634 mm 410 x 434 mm 610 x 1234mm 3' x 3' 1' x 4' 1' x 5' 910 x 934 mm 310 x 1234 mm 310 x 1534 mm Specifications Volume Flow Velocity Range (using 100 mm head) Display Resolution Volume 50-2400 cfm, 85-4078 m3/hr., 24-1133 l/s 50-6000 ft/min, 0.25-30 m/sec 1 CFM, 1m3/hr, 1 l/sec Temperature 1°F, Weight (Instrument and 2’x2’ hood) 0.1°C 9.7 lbs., Memory Locations 4.4kg 99 Output Battery Type/Life RS232 4xAA Alkaline 35 hours Standard Volume flow kit with 2x2 foot hood, soft case Options Fabric Hood (Red, Yellow, Orange, Blue, Gray) Carrying Case, 4" vane kit 10 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Airflow Transducer Model 6332 & 6332D Features: • 10 interchangeable probe options • Probes quickly and easily attach/detach • Digital Display Option (model 6332D) • Selectable Output (Output can be set to either voltage: 0 to 5V or current: 4 to 20mA) Model 6332 (without display) Main Unit Specifications Measuring Object Measuring Range Measuring Accuracy Temperature Compensation Range Selectable Output Option Selectable Range Option Display Resolution (Model 6332D only) Power Supply Power Consumption (Reference Value) Connection Wire Size Temp Range Dimensions Weight Standard Accessories Optional Accessories Clean air and compatible, non-combustible gases Maximum range 0.1 ~ 50 m/s (Range dependant on probe type*) ± (3% of reading + 0.1) m/s 0.1-4.99m/s 5.00-9.99m/s 10.0-24.9m/s 25.0-50.0m/s 5~40°C ±0.25m/s ±0.50m/s ±1.25m/s ±2.50m/s 40~80°C ±0.35m/s ±0.70m/s ±1.75m/s ±3.50m/s (Set via onboard Dipswitch). Current output: DC 4~20mA (Max. load resistance: 250Ω) Voltage output: DC 0~5V (Rotary Switch selectable). 0~2, 0~5, 0~10, 0~25, or 0~50 m/s Velocity Range: 0~2, 0~5, 0~10 m/s → Display Resolution: 0.01m/s Velocity Range: 0~25, 0~50 m/s → Display Resolution: 0.1m/s DC 12~24V Approx. 2.0W (Under the following conditions - power supply: 12V, air velocity: approx. 10m/s, using a unit with a display with probe model 0965-03.) Power consumption rate is subject to change according to conditions such as air velocity, probe type and use of display. 2 0.5 ~ 1.5 mm Operating Temp: 41 to 104°F (5 to 40°C), Storage Temp: 14 to 122°F (-10 to 50°C) Approx. 5” x 3.1” x 1.2” (128 × 78 × 30 mm) Approx. 11oz (320g) Operation Manual : 1, Main Unit Case: 1 Probe Cable (33ft (10m), 66ft (20m), 98ft (30m)), Display Unit (Supplied with a case with a display window and 2 installation screws.), Dedicated AC Adapter (DC12V) Probe Specifications MODEL 0962-00, 0963-00 0964-01, 0964-02 0965-00, 0965-01 Measuring Range 0.1~50.0m/s 0.1~25.0m/s 0965-03, 0965-04 0.1~25.0m/s 0965-07, 0965-08 Sensor Type Uni-directional Omni-directional (Needle) Omni-directional (Spherical) Mini-temperature-compensation-sensor integrated type Omni-directional (Spherical) Mini-temperature-compensation-sensor independent type Omni-directional (Spherical) 11 Airflow Transducer Model 6312 Air Velocity, Air Temperature, Relative Humidity, Differential Pressure Features: • Keep high quality of products by airflow control • Maintain cleanliness by airflow control • For creation of comfortable environment • Optimal for various air-conditioning (air velocity and airflow rate) control equipment • Space saving design • Traceable certificate available • Current output range is 4 to 20mA Main Unit Specifications 20 – 394 fpm (0.1 – 2.0 m/s) Air Velocity Measuring Range Accuracy: +/-30fpm (0.15m/s) Temp. Compensation 64 – 82ºF (18 – 28ºC) Signal Output 4 – 20mA Power Supply DC 24V Operational Conditions Clean airflow with normal temperature and humidity Accessories Probe Cable: 16 feet (5m) Probe Specifications Model Dimensions Quality of material 0941 0942 0.2” x 0.4” x 3.0” φ0.4” x 4.3” (5.5 x 11 x 75mm) (φ11 x 108mm) Molded Resin SUS 12 Thermohygrometer, Sounds / Noise Measurement Thermohygrometer Model 6841 Indoor Environmental Measurement Products Quality Control Features: • Ultra light and palm-size • Easy to use (Select temperature, humidity, or power on/off) Specifications Measuring Object Measuring range Clean airflow Temperature -4 to 113ºF (-20 to 45ºC) Humidity Display resolution 5 to 95%RH Temperature 0.1ºF or 0.1ºC Humidity Accuracy 0.1%RH Temperature +/-0.9ºF (+/-0.5ºC) Humidity +/-3%RH Responsiveness 30 sec Measuring Function Dimensions Conversion between ºF and ºC Main Unit Approx. 2.4” x 4.7” x 1.3” (60 x 120 x 34mm) Probe Approx. φ19 x 170mm Cable Approx. φ3.3 x 1.5m Power Supply Operating Environment AAA Battery x 4 (Mn, Alkaline, or Ni-Cd) Main Unit 41 to 104ºF (5 to 40ºC) Probe -4 to 113ºF (-20 to 45ºC) Storage 14 to 122ºF (-10 to 50ºC) Temperature Weight (including batteries) Approx. 6.3oz (180g) Accessories AAA Mn batteries x 4 13 IAQ Monitor, Gas Monitor Indoor Air Quality Monitor Model 2211 Multi-Parameter Indoor Air Quality Monitor IAQ Investigation Environmental Health and General Safety Thermal Comfort Measurements Features: • Simultaneously measure and log data with multiple parameters such as CO, CO2, Temperature, Relative Humidity, to monitor indoor air quality conditions • Calculates Dew Point, Web Bulb Temperature, Absolute Humidity, Humidity Ratio and % Outside Air • Built-in memory allows user to store multiple point measurements Benefits: • Easy user calibration with built-in calibration function • Capable to continuously monitor parameters via PC • Large LCD shows multiple parameters at a glance Specifications CO CO2 Temperature Range Accuracy Accuracy 0 – 5000PPM +/-3% of reading or +/-50PPM whichever is greater Range -4 – 140ºF (-20 – 60ºC) Accuracy Range Humidity Accuracy Normal Mode Calculation Mode +/- 1ºF (+/-0.5ºC) 2 – 98%RH 2 – 80%RH: +/-2%RH, Calibration Mode Digital Analog (Option) 80 – 98%RH: +/-3%RH Normal measuring: Relative humidity, CO, CO2, Dew point, Wet bulb temperature, Absolute humidity, and Humidity Ratio Store the data, and calculate the maximum, minimum and average value % OA Mode Data Output Mode Outputs +/-3% of reading or 3PPM whichever is greater Range Relative Functions 0 – 500PPM Measure ventilation ratio Perform re-calculation of stored data and output of data to PC and Printer. Perform the calibration of CO and CO2. RS-232C (Baud rates:4800,9600,19200,38400bps) DC0~1V (Select 1 ch among CO, CO2, temperature, and relative humidity) Power Supply AA Battery×6 (Alkaline or Ni-Cd), AC adapter:AC100~240V (50/60Hz)(Optional) Battery Life Approximately 10 hours (at 77ºF (25ºC) with alkaline batteries, without RS232C) Operating Main Body Environment Probe 41-104ºF Storage Environment Standard Kit Optional Accessories (5~40ºC) - 4 - 140ºF (-20~60ºC) - 4- 140ºF (-20~60ºC) Mn Battery × 6, Calibration cap, Connection tube Analog Output, Serial Printer, Communication Cable (For Computer and Printer), AC Adapter 14 IAQ Monitor, Gas Monitor Aeroqual Series 200 Multi-Sensor Handheld Gas Monitor The Series 200 can be hand held or fixed in position. It is a simple, easy-to-use, low-cost monitor that displays the gas concentration. The monitor is compatible with the full range of Aeroqual gas sensors Sensor Head Monitor Base Specification Measurement units ppm Power supply 12 VDC, 800 mA Standard 9.6V (940mA/hr Ni-Cd) Long Life 9.6V (2100mA/hr Ni-MH ) Rechargeable battery pack (2 x options) Permanently fixable Screw fix Enclosure rating IP20 & NEMA 1 equivalent Size (with sensor head) 7.6 x 4.8 x 2.1 (in); 195 x 122 x 54 (mm) Weight (with sensor head and battery) < 16 oz; < 460 g Functions Remote sensor capability , Removable / replaceable sensor head, Low battery indication, Sensor condition status, Standby mode Approvals Part 15 of FCC Rules, EN 50082-1: 1997, EN50081-1: 1992 Sensor Head Specification Ozone Measurement range Accuracy T90 response Low 0.000 - 0.500 ppm < 0.008 ppm (0 0.100 ppm) ±10% (0.100 – 0.500 ppm) < 60 seconds (T90) Sensor type Operating temperature range Operating relative humidity range Approvals VOC* High Leak 0.50 - 20.00 ppm 0.00 - 50.00 ppm ±10% (0.20 2.00 ppm) ±15% (2.00 20.00 ppm) < 35 seconds (T90) ±20%, 15 seconds after Reset < 10 seconds Gas-sensitive semiconductor 23°F to 122°F ; -5°C to 50°C (sensor head and base unit) 95% maximum (sensor head and base unit) --- --- --- * Specific Calibrations to other VOC’s available – contact Kanomax Sales 15 Ammonia CO 0 to 400 ppm toluene < ±10 ppm (0 – 200 ppm); < ±10% ( > 200 ppm) 0 to 1000 ppm < 60 s < 60 s < 150s Gas-sensitive semiconductor -4°F to 140°F; -20°C to 60°C 5 to 95% non-condensating --- Gas-sensitive semiconductor -4°F to 140°F ; -20°C to 60°C 5 to 95% non-condensating --- Gas-sensitive semiconductor 32°F to 158°F; 0°C to 70°C 5 to 95% non-condensating UL 2034, BS 7860 < ±5 ppm (0 – 100 ppm); < ±10% (100 – 1000 ppm) 0 to 2000 ppm carbon monoxide < ±10 ppm in the range 0 to 400 ppm IAQ Monitor, Gas Monitor Aeroqual Series 300 & 500 Multi-Sensor Handheld Gas Monitor • • The Series 300 can be hand held or fixed in position and provides a high level of functionality & monitoring capability. The Series 500 includes the same features and functionality of the Series 300 with the added feature of onboard and PC data logging. Sensor Head Monitor Base Specification Measurement units External signal for alarms & control External signal functions Analog output Power supply Rechargeable battery pack (optional) Permanently fixable Enclosure rating Data interface with PC (Series 500 only) On Board Data Logging (Series 500 only) Size (with sensor head) Weight (with sensor head and battery) ppm or mg/m3 Transistor output, 150 mA max Low Alarm, High Alarm & Control 0-5V 12 VDC, 800 mA 9.6V Ni-MH (5 hours operation) Screw fix IP20 & NEMA 1 equivalent Serial RS232 8,000 data points 7.6 x 4.8 x 2.1 (in); 195 x 122 x 54 (mm) < 16 oz; < 460 g Remote sensor capability, Removable / replaceable sensor head, On-board alarm, Alarm status displayed, Low battery indication, Alarm mute function, Sensor condition status, Standby mode Functions (Series 500 only): Data logging independent of PC, Data logging direct to PC, On-board real-time clock, Data logging software supplied Approvals Part 15 of FCC Rules, EN 50082-1: 1997, EN50081-1: 1992 Sensor Head Specification Ozone Measurement range Accuracy T90 response Low 0.000 - 0.500 ppm < 0.008 ppm (0 0.100 ppm) ±10% (0.100 – 0.500 ppm) < 60 seconds (T90) Sensor type Operating temperature range Operating relative humidity range Approvals VOC* High Leak 0.50 - 20.00 ppm 0.00 - 50.00 ppm ±10% (0.20 2.00 ppm) ±15% (2.00 20.00 ppm) < 35 seconds (T90) ±20%, 15 seconds after Reset < 10 seconds Gas-sensitive semiconductor 23°F to 122°F ; -5°C to 50°C (sensor head and base unit) 95% maximum (sensor head and base unit) --- --- --- * Specific Calibrations to other VOC’s available– contact Kanomax Sales 16 Ammonia CO 0 to 400 ppm toluene < ±10 ppm (0 – 200 ppm); < ±10% ( > 200 ppm) 0 to 1000 ppm < 60 s < 60 s < 150s Gas-sensitive semiconductor -4°F to 140°F; -20°C to 60°C 5 to 95% non-condensating --- Gas-sensitive semiconductor -4°F to 140°F ; -20°C to 60°C 5 to 95% non-condensating --- Gas-sensitive semiconductor 32°F to 158°F; 0°C to 70°C 5 to 95% non-condensating UL 2034, BS 7860 < ±5 ppm (0 – 100 ppm); < ±10% (100 – 1000 ppm) 0 to 2000 ppm carbon monoxide < ±10 ppm in the range 0 to 400 ppm IAQ Monitor, Gas Monitor Tracer Gas Hardware As Per ANSI/ASHRAE Standard 110-1995 In-line Tracer Gas Diffuser Flow (Ejector) IAQ Investigation Industrial Hygiene Quality Control Meter Features: The Kanomax tracer gas diffuser is for use in performing the Tracer Gas test in accordance with ANSI/ASHRAE Standard 110-1995. Our diffuser is an improved design and meets the specifications of Standard drawing #110-83M. The diffuser is placed in the fume hood and sulfur hexafloride gas is injected at a supply pressure of 30 psig.The internal critical orifice ensures a flow rate of Regulator Dif-Kit 4 liters per minute. Other orifice sizes can be inserted. Also available is the Kanomax model Dif-Kit. The Dif-Kit supplies all the required hardware from the cylinder regulator to the diffuser. This includes the diffuser, tank regulator, in-line flow meter, shut-off valve, pressure gage, and 25 ft. of tubing. The in-line flow meter provides a secondary verification of flow rate to the critical orifice, as required by the Standard, so as to alert the user to any clogging or wear of the orifice. The orifice and other components are serviceable by Kanomax. Specifications Critical Orifice Regulator Flow Meter Pressure Gage Options 4 or 8 Liter Per Minute (4Lpm Standard) Dual Stage, Specialty Gas Calibrated 150mm/200psi, Glass Tube Large Dial, 0 to 60psi Rebuild Kit (includes new Critical Orifice, washers, Bronze Sinter Filter) 8Lpm Swappable Ejector Base 17 Particle / Dust Monitor Piezobalance Dust Monitor Model 3521 Respirable Aerosol Mass Monitor NIST Traceable IAQ Investigations Environmental Measurements Product Quality Control Laboratory Research Features: • Data logging ability allows user to log 500 samples • Simple cleaning mechanism for easy maintenance • RS232C port available as standard • Back-lit display is easy to read in poor lighting conditions Benefits: • While conventional dust meters “count” particulates, the Piezobalance dust meter “weighs” mass concentration of particulates • Data can be reviewed on-screen, printed or downloaded to a computer • Software included for easy data download and processing • Easy operation requires no special training Specifications Measuring Object Airborne Particulate Matter < φ10 µm Measuring Range 0.02-10mg/m3 Sampling Flow Rate 1liter/min Preset: 120 sec or 24 sec Measuring Time Accuracy Cleaning Frequency Data Logging Digital Output (To PC or printer) Power Supply Manual: 10sec to 3600sec +/-10% of rdg +/-1 digit (0 to 5mg / m3) +/-20% of rdg +/-1 digit (5 to 10mg / m3) Cleaning is required after every 10-20 measurements. "CLEANING" will appear on the display when it needs to be cleaned. Max 500 date and time stamped samples RS232C (Baud Rates 4800, 9600, and 19200) AC (85V-240V) or DC Ni-MH battery 2.6” x 5.9” x 7.1” Dimensions (65 x 150 x 180mm) Weight Approx. 4.4lbs. (Approx. 2kg) 18 Particle / Dust Monitor Digital Aerosol Monitor Model 3431 Compact Dust/Aerosol Monitor NIST Traceable Indoor Air Quality Investigation Industrial Hygiene Health & Safety Applications Exposure Monitoring Manufacturing Process Control Features: • State-of-the-art components based on advanced light-scattering technology • Compact and Light Weight • Easy operation Benefits: • Accuracy is ensured to meet the latest needs of dust measuring in extremely clean indoor environments • All measurements can be made with a touch of a button on the front panel. • Allows the user to pre-enter the known concentration conversion value and let the unit automatically convert the dust count into mass concentration Specifications Measuring Method Light Scattering Method Measuring Object Measuring Range Accuracy Aerosol particles, φ10µm or smaller 3 0.001 – 3.999mg/m (1 – 9999cpm, 1cpm=0.001mg/m3 for φ0.3µm stearic acid particles) +/-10% of reading +/-1cpm (or 0.001mg/m3) Linear Characteristics Measuring Time +/- 5% of reading 1 minute / 3 minutes / 10 minutes with built-in timer, and continuous mode Light Source Laser diode Detector Photo diode Operating Environment Display Indicators Output Power Supply Dimensions Weight Accessories Options 35 – 104ºF (5 – 40ºC) under 85%RH 4-digit LCD, dust count value (cpm), relative mass concentration value Cleaning, measuring mode, battery status, concentration conversion operation, zero point confirmation Analog output, 0 – 10,000cpm = 0 – 4V AC 100V adapter and dry cell batteries (6 x AA batteries) 6.4” x 2.4” x 39” (162 x 62 x 100mm) not including the nozzles 2.2 Lbs. (1kg) not including batteries AC adapter, micro-screwdriver, alkaline dry cell batteries (6 x AA) shoulder strap Carrying case, Soft case, Analog output cable 19 Particle / Dust Monitor Handheld Laser Particle Counter MODEL 3887 NIST Traceable Cleanroom certification IAQ investigations Food Industry Filter Testing Aerospace Hospital Surgical Rooms Paint Spray Booths Features: • Displays 3 particle sizes simultaneously (0.3, 0.5, 5.0 um) in cf or m3 • Built-in flow sensor (0.1 CFM +/- 10%) • User can log up to 8,000 measurements with easy transmission to PC or Printer. • Fits in your palm Benefits: • Batteries can be altered with regular AA alkaline batteries • Comes with a network capable of up to 8 units using optional Windows software Specifications as a standard accessory Measuring Particle Size 0.3, 0.5, 5.0um Light Source Counting Efficiency Zero Count Coincidence Loss Laser Diode 50% @ 0.3 um; 100% for particles > 0.45 um (per JIS B9921: 1997) ≤1 count / 5 minutes (per JIS B9921: 1997) <5% @ 2,000,000 particles/cf Flow Rate Sampling Time Sampling Frequency 0.1 cfm (2.83l/min) 1 sec to 99 minutes 59 sec (1 sec increments) 1 to 99 times or Continuous Count Alarm Mode of Measurements 1 - 70,000,000 counts Single / Repeat / Continuous / Calculation / Remote / ISO <C4 Display Error 20 letters, 4 lines Max. concentration, Laser Power, Flow Rate and Battery Interface RS232C or RS485 Baud Rate 9600bps Buffer Memory 8000 measurements Power Supply 4 x AA NiMH battery or Alkaline, AC Adapter (100 - 240V) Operating Hours Dimensions Approximately 3 hours (NiMH) 4.3” x 7.7” x 2.7” Weight Operating Conditions Accessories Options (108 x 196 x 68 mm) 1.5 lbs (680g) 50 - 95ºF (10 - 35ºC) AC Adapter, Zero Filter, Software, Communication Cable, 4xAA NiMH, Battery Charger Printer, Printer Cable, Carrying Case, Tripod 20 Particle / Dust Monitor Handheld Laser Particle Counter MODEL 3886 GEO-α NIST Traceable Cleanroom certification IAQ investigations Food Industry Filter Testing Aerospace Hospital Surgical Rooms Paint Spray Booths Features:. • Measures 5 particle sizes simultaneously (0.3, 0.5, 1.0, 3.0 and 5.0 um) in cf or m3, displaying 2 channels • Built-in flow sensor (0.1 CFM +/- 10%) • Temp./RH and Air Velocity probes available as an option • Capable of measuring up to 4 parameters in one instrument. Specifications 5 Size Channels 0.3 um; 0.5 um; 1.0 um; 3.0 um; 5.0um Flow Rate 0.1 cfm (2.83 l/min) Light Source Laser Diode Calibration Counting Efficiency Zero Count Coincidental Loss Sampling Time PSL particles in air 50% @ 0.3 um; 100% for particles > 0.45 um (per JIS B9921: 1997) ≤1 count / 5 minutes (per JIS B9921: 1997) <5% @ 2,000,000 particles/cf 1 sec - 99 min 59 sec, 1 second increment Sampling Frequency Count Modes 1 - 99 or continuous Single, Repeat, Continuous, Calculation and Remote Display 20 letters, 4 line LCD Interface RS232C or RS485 Baud Rate 9600 bps Buffer Memory AC Adapter Power 500 sample records 5VDC at 2.5A, 100 - 240VAC, 50 to 60 Hz 4 x AA NiMH Rechargeable Battery Vacuum Source Dimensions 3.5 hrs with 1600mAh batteries Internal pump, flow controlled 4.5" x 2.8" x 8.5" Weight Accessories Options (115 mm x 70 mm x 211 mm) 2.2 lbs (1 kg) AC Adapter, Zero Filter Isokinetic Probe, Air Velocity Probe, Thermal Printer, Temperature/Relative Humidity Probe, Carrying Case 21 Particle / Dust Monitor Airborne Particle Counter Model 3900 Portable Laser Particle Counter NIST Traceable Monitor and verify cleanrooms Pharmaceutical, Food Industry, Semiconductor Filter testing Facility certification Features: 28.3 L/min (1.0 cfm) flow rate 0.3 micron minimum sensitivity Store up to 5000 measurements All stainless body Large touch screen Multi-function: Measuring particle, airflow, temperature relative humidity, and differential pressure Specifications 22 Particle / Dust Monitor Cleanroom Facility Monitoring Condensation Nucleus Counter NIST Traceable MODEL 3855 Cleanroom Monitoring IC Production HDD Testing MEMS Features: • Condensation Nucleus Counter for continuous multi-point monitoring in cleanroom. • 0.01μm sensitivity. • Less downtime by less alcohol replacement. • Easy checking of the current status on the LEDs Benefits:. • Ideal for ultrafine particle detection • Easy maintenance • No more headaches in cleanroom using Propylene Glycol Specifications Type Principle Maximum Concentration Sensitivity Sensor-Counter Isolated Type Vapor/Air Mixing Type Condensation Particle Counting 3×106 Particles / cf 0.01µm (50% Counting Efficiency) Measuring Accuracy Coincidence Loss Sampling Flow Rate Flow Rate (100 Particles/cc) 0.02µm: 100% ± 10% Less than 5% at 3,000,000 Particles/cf 0.1CFM (2.83L/min) ± 10% 4.2 ± 0.4L/min (Requires external vacuum source) Alcohol Propylene Glycol Indicators Ready, Liquid Level, Flow, Optics, Particle Interface RS‐232C and RS‐485 Output Operating Environment Dimensions Output for M/P or Analog Output Temperature: 9.8” x 9.8” x 11” (250 × 250 × 280mm) ( Excludes alcohol bottle ) Weight Approx. 22lbs (10Kg) Power Supply Accessories Options 20~30ºC ( 68~86ºF ) Clean Air Environments (e.g. Clean Rooms) AC100 ~ 240 V AC Cable, Operation Manual, Alcohol Bottle ( 200cc ), Bottle Holder Alcohol Bottle ( 1000cc ), Bottle Holder 23 ( for 1000cc ) Particle / Dust Monitor Cleanroom Facility Monitoring Facility Monitoring Laser Particle Sensor MODEL 3792 NIST Traceable Cleanroom monitoring Pharmaceutical, Aerospace/ Defense Electronics, MEMS, Semiconductor Food processing Medical / Hospitals Features:. • • • • • • 0.2um/0.3um sensitivity Built-in sonic nozzle for accurate and consistent flow Built-in LEDs for sensor status at a glance Compact stainless body Temperature/Relative Humidity sensors available as option Status LED shows Particle, LD Status, and Flow Specifications Model Sampling Air Flow Sensitivity Condensation Range Type A Output Type B Display Status LED Power Supply Dimensions Weight 3792-01 3792-03 2.83 l/min 1 l/min 0.2 μm, 0.3 μm 0.2 μm, 0.3 μm 1,000,000 pieces/cf 3,000,000 pieces/cf RS-485 Output Connector Type RS-485 IN Modular Connector 8-pin (rear panel) RS-485 OUT Modular Connector 8-pin (rear panel) Transmission Setting: DIP switch 8-pin (front panel) Address Setting(0-999): Rotary DIP switch, 10 positions x 3 (front panel) Multiplexer Output Connector Type: BNC Connector 4-20mAOutput Output: Data for 2 particle size ranges and Sensor Status Connector Type: D-sub Connector 9-pin (rear panel) Indicative Resolution: 1/1000 of the full scale Full Scale: 3 levels (100、10,000、1,000,000 pieces / cf) Full Scale Selection: Sliding DIP switch 8-pin (front panel) Multiplexer Output Connector type: BNC Connector 5-Digit LCD Optional Display unit available (needs to be exchanged with the supporting casing) Condensation Display(Running Average for pre-set time) SIZE key gives selection of Particle size range to monitor PARTICLE: Turns Red when picking the signal of the particle STATUS: Steady Green when Optics is operating normally. FLOW: Turns to Green when Sampling Flow rate is normal AC 100V-240V 4.6” x 5.3” x 6.7” (118×135×170 mm) (Excluding sampling air nozzle on the upper surface and other interface outfit. Also excludes rubber feet.) Approx. 6.6lbs (Approx. 3kg) 24 Cleanroom Facility Monitoring Facility Monitoring Laser Particle Sensor MODEL 3714/3715 NIST Traceable Cleanroom Facility Monitoring • Pharmaceutical • Aerospace/ Defense • Electronics • Semiconductor • Food Processing • Medical / Hospitals Features: • 0.3um/0.5um for Model 3714 & 0.5 um /5.0 um for Model 3715 sensitivity • Built-in sonic nozzle for accurate and consistent flow • Built-in LEDs for sensor status at a glance Benefits: • Compact stainless body • Temperature/Relative Humidity sensors available as option • Status LED shows Particle, Status (LD), and Flow (Optional) Specifications Model Particle Sizes 3714 3715 0.3um/0.5um 0.5um/5.0um Flow Rate Concentration Range Flow Control Light Collection Light Source Light Detector Status LED Measuring Accuracy 0.1CMF ( 2.83 L/min ) 0~1,000,000 particles / cf Sonic nozzle ( Requires external vacuum source ) Laser-light-scattering, wide-range light collection by side mirror 780nm Laser diode Photodiode PARTICLE, STATUS (LD), FLOW Power Supply Dimensions (Optional) +/-10% of reading Interface Connector Type ( LD ) RS-485 RJ45 connector Supplied from the Distributor or Power Unit 2.8” x 5.0” x 1.6” (72 × 126 × 40mm) Weight Approx. 2.2lbs (Approx. 1kg) 25 Cleanroom Facility Monitoring Cleanroom Monitoring System Features:. • On-site monitoring of condensation by built-in LCD • Light and compact body does not require large space • CPU loaded and RS485 output • Steel stand and attachment plate for various installation needs • Quick connect cabling via modular connection • Simple vacuum tubing/pressure connected • Compact laser particle sensor (LPS) with built-in LCD for continuous monitoring of aerosol level • Multi-function, use-friendly monitoring software • Reduced piping & wiring using a single compact pump for entire system • Interface unit for environmental sensors such as temperature, relative humidity, differential pressure, etc. Distributor (Model 3770) Supplies power to a maximum of 8 sensors or interface units. Input 8 channel RS-485 Interface Power Dimensions Weight 26 Baud: 4800/9600/19200bps AC 85-132V/170-264V 11.8” x 3.9” x 7.9” (300 x 100 x 200mm) Approx. 6.6lbs (Approx. 3kg) Aerosol Research Instrumentation Hand-held Condensation Particle Counter Model 3800 NIST Traceable Indoor Air Quality Investigation Aerosol Research Filter Tests Environmental Monitoring for • Electronics • Food Processing • Pharmaceutical • Medical / Hospital, etc. Features: • 0.015 µm sensitivity • Concentration range of 0 to 100,000 particles/cm3 • Programmable data-logging capabilities • Power Supply can be selected from alkaline/Ni-MH battery or AC adapter • Simple to download the data to your computer via USB Specifications Measuring Particle Size Concentration Range Counting Efficiency Zero Count 0.015 to > 1µm 0 to 100,000 particles/cm3 50nm: 100±20% (15nm: More than 50%) Less than 1 particle/ cm3 Flow Rate Alcohol Supply Aerosol Flow: 100cc/min Total Flow: 700cc/min Type Hours per Fill 100% reagent-grade isopropyl alcohol Approx. 5 hours at 23ºC(73° F) Absolute Pressure Sensor Mode of Measurements 150 to 1150 hPa Repeat / Program / Counter Display Interface Built-in LCD ( 128 x 64 dots) USB Buffer Memory Power Supply Type Operating hours Environmental Operating Condition Dimensions Weight Standard Accessories Options Max. 10,000 measurements 6 pieces of AA-size Alkaline / Ni-MH battery or AC adapter (Input 100 – 240V) Approx. 5 hours ( By Alkaline batteries ); Approx. 8 hours ( By Ni-MH batteries ) Ambient temperature range: 10 to 35ºC ( 50 to 95° F) 4.7”(W) x 11”(H) x 5.1”(D) (120 x 280 x 130mm) Approx. 3.3lbs (1.5kg) ( without batteries ) AC adapter, Zero filter , Alkaline battery×6, Operation manual, Software(for Windows), PC Communication Cable, Carrying Case Ni-MH battery (1.2V-2500mA) x 6, Charger x 2, Printer, Printer cable, Printer AC adapter 27 Aerosol Research Instrumentation Aerosol Particle Mass Analyzer Model APM-3600 This analyzer classifies the mass of a single aerosol based on the balance between centrifugal force and electrostatic power Diesel Exhaust Aerosol Research Nano-Particle Aerosol Research Atmospheric Aerosol Research Bio-Chemical Applications Features: The APM-3600 classifiers particles for each particle size, based on the aerodynamic movement of the particles. This analyzer uses our own rotating mechanism and seal technologies, as well as taking into consideration the static effects and flow of the fluid. Main Body Specifications Classifying method Classifying mass range Double cylinder rotating Double cylinder high voltage Double cylinder dimensions Sampling Flowrate Dimensions Weight Classification is based on the balance between centrifugal force and static power. Approx. 0.01~100 Femto-gram(For particle concentration of 1g/cm3 approx. 40nm~500nm, classification accuracy is within ±30% regarding center mass) ~8,000rpm ~3,000V Inner cylinder diameter: 3.9” (100mm), Outer cylinder diameter: 4.1” (104mm), Cylinder length: 9.8” (250mm) Above 1L/min 15.7” x 15.7” x 47.2” (400mm x 400mm x 1200mm) Approx. 165lbs (75kg) Control, Display Control function Display function Control Method Dimensions Weight Power supply Rotation rate and applied voltage Applied voltage / Rotation rate / Differential pressure (Panel display) Control by panel, Control by PC (By Manual / Remote Switch) 16.9” x 16.9” x 11.8” (430mm x 430mm x 300mm) Approx. 55lbs (25kg) AC100V、50/60Hz 28 Fluid Mechanics Research Instrumentation Smart LDV System High Quality and Compact LDV System Features:. • The best device for precision PIV calibration and measurement of medium or low velocity • Easy to use Specifications Available velocity -10m/s~30m/s (Please contact us of the application to over 30 m/s.) Laser Focal Distance Optics Laser Diode, λ=635nm, 10mW 150mm (Options:170mm, 200mm, 250mm) Measurement Volume 0.09mm×0.7mm Measurement Method Back Scattering/Forward Scattering (A retro reflector mirror is used with a standard model to obtain high signal quality) Probe Size 60mmφ×300mm Shift frequency Signal Processor 0.01-10MHz(1-2-5step) Signal Processing 8-bit FFT(512,256,128 points) Frequency Range 1kHz~40MHz (8 ranges) Max. Data Rate 8000 Data/sec Effective Judgment Burst spectrum ratio Computer IBM PC Compatible Max. Number of Data Software 99,000 Realtime Monitor Burst signal, Burst spectrum, Velocity histogram Data Processing Mean velocity, Turbulence intensity, Skewness factor, Flatness factor, Velocity histogram, Time history Data Output CSV Format 29 R & D / Test Instrument and System Amenity Manikin For Automotive Interior Environmental Measurement R&D Design Engineering Features: The life sized Manikin is designed to accurately emulate the positioning of a driver or passengers torso, arms and legs while seated in the vehicle passenger compartment. Placement and positioning is simple and data collection can be started immediately. The Manikin deploys over 120 sensors that can be custom configured by the end-user on-sight. There are 4 sensor types to choose from that include Air Velocity, Air Temperature, Relative Humidity and Radiant Heat. The system components include the Manikin with built-in data processor, Sensors, Power and Data Transfer Unit, PC Interface, Monitoring PC and Data-Logging Software. Up to 2 Manikins can be linked to a single monitoring PC. Manikin Specifications Height Approx 5’7” (Approx. 170cm) Weight 88lbs (40kg) including data processor Material Plastic (FRP) Sensor allocations (example) Air Velocity Temperature Relative Humidity Radiant Heat Head 4 12 1 3 Upper Torso 12 33 0 5 Lower Torso 20 33 1 4 Total 36 45 2 12 Sensors Specifications Range Air Velocity Temperature Accuracy Range 20 – 984fpm (0.1 - 5 m/s) 20 – 394fpm (0.1-2m/s) ±10fpm (0.05m/s) 394 - 984fpm (2-5m/s) ±20fpm (0.10m/s) -22 – 212F (-30 - 100ºC) Accuracy ±4.6F (3ºC) Range Humidity 3-95%RH 3-30%RH Accuracy Wavelength Radiant Heat Range Accuracy ±3%RH 30-75%RH ±2%RH 75-95%RH ±3%RH 0.3-40µm 0-1Kw/m2 ±7% 30 34
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement