advertisement
nSure
TNS541
Seamless TS Monitoring Switch
The TNS541 is an ideal solution for intelligent 1+1 redundancy switchover between two MPEG transport streams.
It improves the robustness of the
Applications
• All systems requiring intelligent 1+1 switchover between two MPEG transport streams.
• Seamless switchover in DVB-T/T2 SFN networks system with dual power supply and seamless switchover with no
Key features interruption to the transport stream.
• Seamless TS switchover
The TNS541 ensures more reliable and robust delivery of video as it continuously monitors health status of the incoming signals and switches over if errors are detected.
Delay differences are handled by matching and alignment of packets and switchover is based on highly configurable switching criteria.
• Frame aligned seamless switchover
• Robustness and flexibility
• Transport Stream monitoring and error detection
• User-friendly configuration and control
The TNS541 is also capable of performing synchronized and seamless switchover between two different SFN streams or T2MI streams in such a way that modulators remains synchronized.
The TNS541 is part of Nevion’s nSure product line which is designed to ensure the delivery of high-quality video content. The nSure product line simplifies the monitoring, analysis and switching of transport streams and services throughout video broadcast networks.
TNS541 Seamless TS Monitoring Switch
Inputs
ASI in
2 inputs
ASI in
2 inputs
Buffer management
ASI passthrough (x2)
Monitoring Switching
Buffer management Monitoring Switching
Outputs
ASI out
1 power safe
2 configurable
ASI out
1 power safe
2 configurable
Management & Alarms
HTML
XML
SNMP
TXP
Alarm relay
Clock & time base
• 1PPS regulator
• UTC time source
Power
• Dual 230V AC
• 48V DC
SNTP 1PPS
Configuration
Alarm logs
Alarm traps
Seamless TS switchover
Seamless switchover between incoming streams without interruption on the output. Incoming streams are matched and aligned to handle delay differences.
Robustness and reliability
Dual power supply for increased reliability. Relay protected
ASI outputs ensures signal passthrough in the event of power loss or power supply failure.
SFN seamless switchover
Synchronized and seamless switchover between two different SFN streams or T2MI streams ensures that modulators remains synchronized in an SFN network.
Transport Stream monitoring
Continuous and simultaneous monitoring and error detection of input signals to ensure error-free operation.
Error detection is performed according to ETR 101 290 priority 1,2 and 3.
Adaptive stream matching
Transport streams can be matched and aligned according to several criteria. The TNS544 can perform regular TS matching or use SFN information for matching.
Flexible switching criteria
Easy configurable switching criteria to provide maximum flexibility to the user. Manual or automatic switching based on ETR 290 alarm conditions enable the tailoring of the redundancy behaviour.
User-friendly configuration
The user interface of the TNS541 is simple and very intuitive, it is designed to help the operator configure the unit quickly. Running on any web browser the GUI can be accessed from any computer.
TNS541 Seamless TS Monitoring Switch
Transport Stream interfaces
DVB-ASI 2 DVB ASI EN 50083-9, Annex B inputs
Up to 2 failsafe DVB ASI outputs
Up 4 additional configurable DVB ASI outputs (buffered)
188 or 204 byte packet length
Burst and Spread mode
Female BNC connectors 75 Ohm
Switching capabilities
No. of switches 1-2 switches per unit
No. of input per switch 2 TS inputs per switch
Switch configurations 2:1
No. of outputs
Switching modes
Matching modes
1- 6 TS outputs copies per switch
Manual
Automatic with input prioritization
Transport Stream
SFN using MIP (DVB-T) and T2-MI (DVB-T2)
TS delay compensation Automatic or manual
Frame aligned switchover between SFN streams from two CP525 cMUX
Remultiplexers with preservation of MIP packets
Frame aligned switchover between T2MI streams from two CP560 DVB-T2 Gateways with preservation of T2 time stamps.
Monitoring & alarms
Monitoring ETR 101 290 Priority 1, 2, 3 real-time monitoring of all
inputs
Configurable thresholds values.
Effective and total bitrate overview of all PIDs.
Service analysis with Service Id, name and components.
PID analysis (Type, scrambling and dynamic bitrate
Graphical view of bitrate
Bit rate monitoring with configurable min and max threshold for any PID
Alarms & logs Standardised alarm levels according to ITU-T X.733
Configurable alarm severity level (individual, PID level, service level, input level)
Circular events log for 10.000 entries
Configurable and exportable (XML, CSV) logs
Time synchronization
UTC time reference SNTP over the management interface (RJ45)
Management & control
Management port 10/100 Base-T Ethernet
Connector: RJ45
Element control through HTTP/WEB based GUI
XML Configuration import and export via HTTP
SNMP agent for integration with Network Management System (NMS)
Protocols
Alarm Relay
Maintenance Port
HTTP, XML, SNMPv2c
9 pin D-SUB. Four relays supported; one at configurable alarm level
USB version 1.1
Physical and environmental characteristics
Input Voltage 100-240V AC +/- 10%, 50/60 Hz, Dual power supply, optional -48V DC
Power consumption
Dimensions
35W max
1RU, full-width 19’’
(WxDxH) 420 x 300 x 44.5mm
Operating temperature 0˚C to 50˚C
Storage temperature -20˚C to 70˚C
Relative humidity
Compliance
5% to 95% (non condensing)
CE: 73/23/EEC (Low voltage equipment) 89/336/EEC
(Electromagnetic compatibility)
CSA: Designed for CSA approval
Safety: IEC60950 and EN60950
EMC: EN55022, EN55024, EN6100-3-2
Product options
TNS541/DC
TNS541/SW
TNS541/GNG
TNS541/SSFN
-48V DC power supply
Input switching units
Dual gang switch
Seamless SFN switching
R1303
nSure
By adding intelligence to monitoring and switching, our nSure products protect both the content owner and the network operator.
We deliver solutions for service fallback, redundancy switching including seamless switching and continuous monitoring of Video signals, Transport Streams, services, PIDs and PSI/SI/PSIP tables. In an increasingly complex broadcast infrastructure, our solutions simplify the day to day operations of the network operator and provide an ideal tool for video signals and Transport Stream handling, redundancy, error detection and correction and fast diagnostics of erroneous signals.
CONTACT INFORMATION
Provided by: Mega Hertz 800-883-8839 [email protected] www.go2mhz.com