Temperature
Temperature
Temperature
Table of Contents
Series 9000 Special Application Thermocouples
and RTD’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .306
Series D Sensors for Sanitary Applications . . . . . . . . . . . . .307
Series P Penetration Probes . . . . . . . . . . . . . . . . . . . . . . . . .308
Series T Temperature Sensor Assemblies
with Thermowells . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .309
Series W Thermowells . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310
Series EC Extension Cables . . . . . . . . . . . . . . . . . . . . . . . . .311
Hand Held Thermocouples . . . . . . . . . . . . . . . . . . . . . . . . . .312
Sensor Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .313
Series RTD Resistance Temperature Detector . . . . . . . . . . .314
Series GT Spirit-Filled Glass Thermometers . . . . . . . . . . . .314
Series BT Bimetal Thermometers . . . . . . . . . . . . . . . . . . . . .315
Series ST Surface Mount Thermometer . . . . . . . . . . . . . . . .315
Series 472 Digital Thermocouple Thermometer . . . . . . . . . .316
Series 472 Kits Digital Thermocouple Thermometer
Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .316
Model TC10 Digital Thermocouple Thermometer . . . . . . . .317
Model TC20 Dual Input Thermocouple Thermometer . . . . .317
Series IR Infrared Temperature Thermometer . . . . . . . . . . .318
Series IRE Infrared Thermometer Expanded . . . . . . . . . . . .319
Model MIR1 Mini Infrared Thermometer . . . . . . . . . . . . . . .319
Model PIR1 Pocket-Size Infrared Thermometer . . . . . . . . . .320
Model IRM20 Noncontact Infrared Thermometer . . . . . . . .320
Model WT-10 Waterproof Thermometer . . . . . . . . . . . . . . . .321
Series MIL Mini In-Line IR Sensor . . . . . . . . . . . . . . . . . . . .321
Series IL In-Line IR Sensor . . . . . . . . . . . . . . . . . . . . . . . . . .322
Series IM/IMS IR Monitoring System . . . . . . . . . . . . . . . . . .322
Series LCT016 Analog Timers . . . . . . . . . . . . . . . . . . . . . . .323
Series LCT116 Digital Timers . . . . . . . . . . . . . . . . . . . . . . . .323
Series LTT SSR Monitors . . . . . . . . . . . . . . . . . . . . . . . . . . .324
Series LTTJ Current Transformers . . . . . . . . . . . . . . . . . . . .324
Technical Reference Books . . . . . . . . . . . . . . . . . . . . . . . . .325
Introduction to Temperature Controls . . . . . . . . . . . . . . . . . .259
Series TCS Thermocouple Temperature Switch . . . . . . . . . .260
Series TS2 Digital Temperature Switch . . . . . . . . . . . . . . . .261
Series TSX Digital Temperature Switch . . . . . . . . . . . . . . . .262
Series TSS Dual Stage Temperature Switch . . . . . . . . . . . .263
Series TS Digital Temperature Switch . . . . . . . . . . . . . . . . .264
Series TSD Digital Temperature Switch . . . . . . . . . . . . . . . .265
Series TSR Digital Temperature Switch . . . . . . . . . . . . . . . .266
Series TST Digital Temperature Switch . . . . . . . . . . . . . . . .267
Series DTS Digital Temperature Switch . . . . . . . . . . . . . . . .268
Series TI Temperature Indicator . . . . . . . . . . . . . . . . . . . . . .269
Series THC Temperature/Humidity Switch . . . . . . . . . . . . . .269
Series 32DZ Temperature/Process Controller . . . . . . . . . . .270
Model 32A Temperature Controller/Process . . . . . . . . . . . .271
Series 16A Temperature Controller/Process . . . . . . . . . . . .272
Series 16L Limit Controls . . . . . . . . . . . . . . . . . . . . . . . . . . .273
Series 1500 Temperature Controller . . . . . . . . . . . . . . . . . . .274
Series 8500 Temperature/Controller . . . . . . . . . . . . . . . . . . .275
Series 8600 Temperature/Process Controller . . . . . . . . . . . .276
Series 2500 Temperature/Controller . . . . . . . . . . . . . . . . . . .277
Series 2600 Temperature/Process Controller . . . . . . . . . . . .278
Series A-900 & A-901 1/4 DIN Control Enclosures . . . . . . .279
Series 1400 Analog Setpoint Temperature Controller . . . . .280
Model 60 Low Cost Analog Thermostat
Temperature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . .281
Series PP45 Temperature/Process Indicator . . . . . . . . . . . .282
Series 1300 Smart Indicator/Transmitter . . . . . . . . . . . . . . .283
Series SI Smart Indicator . . . . . . . . . . . . . . . . . . . . . . . . . . .284
Series LCI132 Process Indicator . . . . . . . . . . . . . . . . . . . . .285
LCI208 4 Digit Panel Meter Indicators . . . . . . . . . . . . . . . .286
LCI108 & LCI108J 4 Digit Panel Meter Indicator . . . . . . . . .286
Series LCI308 & LCI408 Panel Meter Indicators . . . . . . . . .287
Series LCI508/LCI608 Digital Panel Meters . . . . . . . . . . . . .288
Series LCI Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289
Model PM706 Temperature Panel Meter . . . . . . . . . . . . . . .289
Series 650 Temperature Transmitter . . . . . . . . . . . . . . . . . . .290
Series 651 Temperature Transmitter . . . . . . . . . . . . . . . . . . .290
Series 659 Push-Button Temperature Transmitter . . . . . . . .291
Model 652-0 Programmable Transmitter . . . . . . . . . . . . . . .291
Series 1290 & 1490 Loop AlarmsTM . . . . . . . . . . . . . . . . . . .292
Series SC1290 & SC1490 Thermocouple & RTD
Limit/Alarm Switch Module . . . . . . . . . . . . . . . . . . . . . . .292
Series SC4130/SC4151/SC4380 Iso-Verter® II
Signal Conditioning Modules . . . . . . . . . . . . . . . . . . . . .293
Series 4130/4151 Temperature Transmitters . . . . . . . . . . . .294
Model RRT Remote Reading Thermometer with Switch . . .294
Series M-51 Bi-Metal Air Temperature Switches . . . . . . . . .295
Series FM Immersion Temperature Control . . . . . . . . . . . . .295
Series 860 Line Voltage Thermostats . . . . . . . . . . . . . . . . . .296
Series DA-7035N Temperature Switches . . . . . . . . . . . . . . .296
Introduction to Temperature Sensors . . . . . . . . . . . . . .297-298
Thermocouples - RTD’s . . . . . . . . . . . . . . . . . . . . . . . . . . . .299
Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .300
Term Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .301
Series 5000 General Purpose and Bayonet Type
Thermocouples & RTD’s . . . . . . . . . . . . . . . . . . . . . . . . .302
Series 6000 Sensors for Extruders and
Plastic Machines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .303
Series 7000 Protection Tube Assemblies and Replacement
Thermocouple Elements . . . . . . . . . . . . . . . . . . . . . . . . .304
Series 8000 Mineral Insulated Thermocouples
and RTD’s . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .305
258
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
Temperature Controllers
pgs 271-277
Indicators/Transmitters
pgs 282-294
Thermometers
pgs 314-320
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Introduction to Temperature Controls
The temperature of an object is generally described by the relative “Hot” or “Cold” feeling of the item. Several reliable and
reproducible methods exist to establish the relative “Hotness” or “Coldness” of an object and provide a quantitative indication of temperature. Our sensors provide a quantitative indication of temperature through a variety of methods including bulb
and capillary, infrared, bimetal, thermocouple, thermistor and RTD. These technologies are represented on the following
pages.
ELECTRICALLY
OPERATED
VALVE
M
A
R
K
E
T
PRESSURIZED
TANK
MERCOID 215
LEVEL CONTROL
MERCOID
DA SERIES
TEMP
CONTROL
BULB
PRESSURE
WELL
TO
HIGH-LOW
TEMPERATURE
ALARM
Dairy
Produce
Meat & Deli
Noncontact temperature measurement using infrared thermometers.
Use Infrared Thermometers for noncontact, non-contaminating temperature measurement of food items. Quickly verify uniform heating or cooling in food display and food storage areas to eliminate spoilage and product waste. Monitor the temperature of ovens, ranges, deep fryers, and
heated serving areas while maintaining a safe distance from the heat
source. Check refrigeration and heating lines, compressors, motors,
HVAC units, electrical connections, and circuit breakers to verify proper
operation and determine trouble spots early.
PROCESS
WARNING
LAMP OR
ALARM
WATT
TRANSDUCER
HEAT
EXCHANGER
PUMP
-
+
+
0-1mA
OVERPRESSURE
RELIEF VALVE
IN
-
CONTROL
VALVE
DC TRIP ALARM
POWER LINES
2343
4-20mA
+
+
IN
OUT
-
-
TEMPERATURE
SENSOR
+
I/P
-
TEMPERATURE
CONTROLLER
WATER OR STEAM
DC INPUT
ISOLATOR
SCC-C/C
CHART RECORDER
CR20
AIR SUPPLY
Power consumption monitoring with Dwyer SCC signal conditioners,
limit alarms and chart recorder.
Reduce operational costs by monitoring power consumption and alerting
operators if power limits are exceeded. A Watt transducer provides a 0 to
1 mA output proportional to the AC power level. The DC input limit alarm
is set to trip at the appropriate power level. The DPDT relay contacts control a visual or audible alarm. The model DC input signal conditioner converts the 0 to 1 mA signal into a 4 to 20 mA output signal for use with
recording equipment and provides up to 1500 VDC isolation.
Process temperature control using a Hi-Flow™ control valve, an I/P
transducer and a Dwyer controller.
Pneumatic Hi-Flow™ control valves provide excellent control with high
flow capacity, wide rangeability and tight shut-off capabilities. The application shown uses a Lin-E-Aire® pneumatic actuator operating from a
standard 3-15 psi control air signal and a Hi-Flow™ linear control valve
which apportions steam or water to the process. The valve regulates cooling water or steam flow depending on the process requirement resident
in the temperature controller program. This package can be provided with
a Precisor®positioner, 2343, a current to pressure transducer, Proximity
position indicating transmitter and a Dwyer 1600 temperature controller
with thermocouple.
Important Note: The control hook-ups and sketches and other application information shown in this bulletin are generalized and abbreviated to present the basic application only. We
believe this application information to be reliable but it is intended for use by persons, at their own discretion, having technical skill and knowledge of the business. Neither Dwyer Instruments,
Inc., nor any of its divisions including the Mercoid, W.E. Anderson, Proximity or Love Divisions shall be liable for loss, damage or expense directly or indirectly arising from the use of any
product described herein. In no event shall any of these companies be liable for direct, indirect, special or consequential damages.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
259
Temperature
Mercoid® temperature and level controls find wide application in high
pressure and high temperature processes.
The application above shows a Mercoid® DA series bulb and capillary
temperature control monitoring the temperature of media in a holding
tank. This control can actuate an alarm when the media temperature
exceeds the desired temperature limit. A well in the side of the tank protects the bulb from the system pressure and it allows removal of the bulb
and control without disturbing the process. A Mercoid® Model 215, also
shown, can be used to control the level in the tank by turning on or off
an electrically operated valve. This level control features an adjustable
level setpoint from 1.5 to 24 inches and pressure/temperature ratings of
300 psi/500ºF.
Frozen Foods
Series
TCS
Thermocouple Temperature Switch
Heating and Cooling Control, 15 Amp Rating, Two Alarms
C
1-7/64
[28]
1-11/32
[34]
3
[76]
2-3/8
[60]
Temperature
Panel Cutout 2-51/64˝ x 1-9/64˝ (71 x 29 mm)
Monitor and control temperature in heating and cooling applications with the Series TCS Thermocouple Switch. The Series TCS
offers a wide temperature range, two selectable alarm sets, and an
internal buzzer indicating alarm condition or error. The user can
define set point, heating/cooling regulation, cycle time, alarm configuration, load status, and ambient probe adjustment. The thermocouple switch features password protection and error/alarm messaging.
Temperature and output status is indicated on the bright red LED display. Use the configuration key (sold separately) to quickly program
multiple units. The Series TCS includes a fitting clip for panel mounting, gasket, rear terminal cover and instruction manual.
SPECIFICATIONS
Probe Range: 0 to 700°C (32 to 999°F) for thermocouple J .
0 to 999°C (32 to 999°F) for thermocouples K, S.
Input: Type J, K, or S thermocouple depending on model.
Output: 15 A SPDT relay @ 250 VAC resistive.
Horsepower Rating (HP): 3/4 HP.
Control Type: ON/OFF.
Power Requirements: 110 VAC, 230 VAC or 12 VAC/VDC
(depending on model).
Accuracy: ±1% FS.
Display: 3-digit, red, 1/2˝ (12.7 mm) digits, plus sign.
Resolution: 1°.
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 14 to 131°F (-10 to 55°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
Weight: 2.3 oz (65 g).
Front Panel Rating: NEMA 4X (IP65).
Agency Approvals: CE, UR pending.
APPLICATIONS
MODELS
Model Number
Description
TCS-4010
TCS-4011
TCS-4020
TCS-4021
TCS-4030
TCS-4031
TCS-5010
TCS-5011
TCS-5020
TCS-5021
TCS-5030
TCS-5031
Type J input, 110V, °F
Type J input, 110V, °C
Type J input, 230V, °F
Type J input, 230V, °C
Type J input, 12 VAC/VDC, °F
Type J input, 12 VAC/VDC, °C
Type K input, 110V, °F
Type K input, 110V,, °C
Type K input, 230V, °F
Type K input, 230V,, °C
Type K input, 12 VAC/VDC, °F
Type K input, 12 VAC/VDC, °C
TS Digital Temperature Switches are suitable for industrial chillers, environmental chambers, walk-ins and freezers, heat sealers, sterilizers, beer and
wine chillers, mug frosters, coolers, display cases and cabinets, warmers, meat
and produce storage, floral preservation, refrigerated transportation, laboratories, food service equipment, ovens and dryers, tobacco preservation, hot
melt glue stitchers for case erectors, cool rooms, burn-in rooms and chambers,
and cold water citrus packing.
Accessory
TS2-K Configuration Key
PARAMETERS
SP
r0
r1
r2
d0
c0
c2
P1
P5
H5
A0
A1
A2
A3
A4
A5
A6
A7
260
Description
Set point
Differential or hysteresis
Lower Value Set Point
Higher Value Set Point
Heating or Cooling Control
Min. stop time for Load
Load Status During Probe Error
Ambient Probe Adjustment
Ambient Probe Type
Parameter Access code
Alarm 1 Hysteresis
Alarm 1 Threshold
Alarm 1 Exclusion Time
Alarm 1 Configuration
Alarm 2 Hysteresis
Alarm 2 Threshold
Alarm 2 Exclusion
Alarm 2 Configuration
VISIT OUR WEBSITES:
www.dwyer-inst.com
Units
Degrees
Degrees
Degrees
Degrees
Option
Minutes
0/1
Degrees
Option
Numeric
Degrees
Degrees
Seconds
Option
Degrees
Degrees
Seconds
Option
•
www.dwyer-inst.co.uk
Range
r1 to r2
1 to 99°
0 to 999°
0 to 999°
Ht/Co
0 to 59 min.
Off/On
-10 to 10
J, K, or S
0 to 255 (Set at 0 from factory)
1 to 999°
0 to 999°
0 to 999°
Off, 1, or 2
1 to 999°
0 to 999°
0 to 999
Off, 1, or 2
•
www.dwyer-inst.com.au
Series
TS2
Digital Temperature Switch
C
Easy Multi-Unit Programming, 15A SPDT Relay Output
1.338
[34]
1.100
[28]
3.000
[76]
2.375
[60]
Panel Cutout 2-51/64˝ x 1-9/64˝ (71 x 29 mm)
SPECIFICATIONS
MODELS
ACCESSORIES
Probe Range: -58 to 302°F (-50 to 150°C).
Input: PTC thermistor 10001 @ 25°C.
Output: 15A SPDT relay @ 250 VAC resistive, 5A inductive.
Horsepower Rating (HP): 3/4 HP.
Control Type: ON/OFF.
Power Requirements: 110 VAC.
Accuracy: ±1% F.S.
Display: 3-Digit, red, 1/2˝ digits.
Resolution: 1° (<100°); 1° (*100°).
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 14 to 131°F (-10 to 55°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
Weight: 2.3 oz (65 g).
Front Panel Rating: NEMA 4X (IP65).
Agency Approvals: CE, URc, UR.
Model Number
Voltage Supply
Display
TS-5-Probe PVC, 5 ft (1.5 m) cable
TS2-010
TS2-011
110 VAC
°F
°C
TS-51-Probe PVC, 10 ft (3 m) cable
110 VAC
TS-6-Probe metal, 5 ft (1.5 m) cable
TS-61-Probe metal, 10 ft (3 m) cable
TS2-K-Configuration Key
PARAMETERS
SP
r0
r1
r2
d0
d2
d8
c0
c1
P1
H5
t0
Description
Set point
Differential or hysteresis
Lower Value Set Point
Higher Value Set Point
Heating or Cooling Control
Time for Defrosting
Interval Time between Defrosting
Minimum Stop Time for Compressor
Continuous Cycle Time
Ambient Probe Adjustment
Parameter Access code
Maximum Temperature on Display
CALL TO ORDER:
U.S. Phone 219 879-8000
•
Range
r1 to r2
1 to 20
-50 to 150°C (-50 to 302°F)
-50 to 150°C (-50 to 302°F)
Ht/Co
0 to 59 min.
1 to 24 hr.
0 to 59 min.
0 to 24 hr.
-10 to 10°
0 to 99
-50 to 150°C (-50 to 302°F)
Units
Degrees
Degrees
Degrees
Degrees
Option
Minutes
Hours
Minutes
Hours
Degrees
Numeric
Degrees
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
261
Temperature
Monitor and control temperature for heating and cooling
applications with the Series TS2 Digital Temperature Switch. The
Series TS2 offers twelve programmable functions to customize the
unit to fit application requirements. Use the 15(5) Amp SPDT relay
output to drive a motor, compressor, or fan. Designed with the OEM
in mind, the TS2 offers the ability to configure multiple units with the
touch of a button.
Programming multiple units is quick and easy. Simply program one
switch with the desired parameter settings and connect the configuration key (sold separately) to the back of the unit. Press the button
on the configuration key and download the parameter settings.
Connect the key to the other switches to upload the stored settings
with the push of a button.
The TS2 features set point adjustments, static defrost timing, compressor mean time, hysteresis, and ambient probe adjustment.
Security protection is offered using a password code. The Series TS2
Digital Temperature Switches are designed to operate with PTC
(1000Ω @ 25°C) probes sold separately.
Series
TSX
Digital Temperature Switch
Dual Input, Cooling Applications, Single or Dual Relay Output
(1.338)
(1.100)
(3.000)
(2.375)
Temperature
Panel Cutout 2-51/64˝ x 1-9/64˝ (71 x 29 mm)
The microprocessor based Series TSX offers a low cost solution for cooling applications. Units are designed to accept up to two
temperature probes selectable between PTC or NTC thermistor
input. The probe temperature is displayed on the bright 3-digit LED.
The Series TSX offers 23 programming parameters for specific application requirements (see parameter chart below). To quickly program
multiple units with the same settings, use the configuration key TS2K (sold separately). The user can define set point, hysteresis, probe
error performance, and defrosting. The defrosting mode can also be
initiated or interrupted manually by pressing the up arrow button.
Units include password protection to secure from unwanted setting
changes except for set point adjustment. If required, the keypad can
be locked out so no adjustments can be made.
Select from single output units with one 16A SPST relay or dual output with one 16A SPST relay and one 8A SPDT relay for defrosting.
The temperature switch includes one NTC probe, gasket, mounting
clips, and instruction manual.
SPECIFICATIONS
Probe Range:
PTC: -58 to 302°F (-50 to 150°C);
NTC: -58 to 230°F (-50 to 110°C).
Input: PTC/NTC thermistor 10001 @ 25°C.
Output: 16A SPST relay @ 250 VAC resistive, 5A inductive; Dual
output units also have one 8A SPDT relay @ 250 VAC resistive,
3A inductive.
Horsepower Rating (HP): 16A: 1HP 240 VAC - 10FLA, 60LRA
250 VAC.
Control Type: ON/OFF.
Power Requirements: 110 VAC; 230 VAC; 24 VAC/DC; 12
VAC/DC (depending on model).
Accuracy: ±1% F.S.
Display: 3-digit, red, 1/2˝ (12.7 mm) digits.
Resolution: 0.1° (<100°); 1° (*100°).
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 14 to 131°F (-10 to 55°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
Weight: 2.3 oz (65 g).
Front Panel Rating: NEMA 4X (IP65).
Agency Approvals: UR pending.
MODELS
DUAL INPUT, SINGLE OUTPUT
Supply Voltage
Model Number
TSX-10140
TSX-11140
TSX-20140
TSX-21140
TSX-40140
TSX-41140
110 VAC
110 VAC
230 VAC
230 VAC
24 VAC/DC
24 VAC/DC
DUAL INPUT, DUAL OUTPUT
Model Number
Supply Voltage
TSX-10240
110 VAC
TSX-11240
110 VAC
TSX-20240
230 VAC
TSX-21240
230 VAC
TSX-40240
24 VAC/DC
TSX-41240
24 VAC/DC
Degrees
°F
°C
°F
°C
°F
°C
Degrees
°F
°C
°F
°C
°F
°C
Accessories
TS2-K Configuration Key
TS-5 PVC Probe (PTC), 5 ft
TS-6 Metal Probe (PTC), 5 ft
TS-7 Plastic Probe (NTC), 3 ft
PARAMETERS
SP
r0
r1
r2
d0
d1
d2
d4
d5
d7
d8
d14
c0
c2
c3
c4
c5
P1
P2
P4
H1
H5
H6
262
Description
Units
Range
Set Point
Differential or Hysteresis
Lower Value for SP
Higher Value for SP
Type of Defrosting
Temperature Defrosting Stop
Defrosting Duration
Delay of First Defrosting
Display on Defrosting
Compressor Drip Time
Defrosting Interval Time
Defrost Counting Mode
Minimum Stopping Time
ON Time of Fault Cycle
OFF Time of Fault Cycle
Minimum ON Time
Minimum Time Between 2 Activations
Ambient Probe Adjustment
Defrosting Probe Adjustment
Number of Probes
Keyboard Protection
Access Code to Parameters
Probe Type
Degrees
Degrees
Degrees
Degrees
Option
Degrees
Minutes
Minutes
Option
Minutes
Hours
Option
Minutes
Minutes
Minutes
Minutes
Minutes
Degrees
Degrees
Option
Option
Numeric
Option
r1 to r2
1 to 20
-58 to r2
r1 to 302
rE/In
-58 to 302
0 to 59
0 to 999
off/on/-d0 to 999
0 to 24
ct/rt
0 to 59
0 to 999
0 to 999
0 to 999
0 to 999
-10 to 10
-10 to 10
1/2
yes/no
0 to 255
Ptc/ntc
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
TSS
Dual
Stage
Temperature
Switch
Two Independent Relay Outputs, Heating or Cooling Control
C
1.34
[34]
1.10
[28]
2.72
[69]
2.95
[75]
Panel Cutout 2-51/64 x 1-9/64 (71 x 29)
PARAMETERS
Set 1
Set 2
r0
r1
r2
r3
r4
r5
r6
r7
r8
A0
A1
A2
A3
A4
A5
c0
c1
c2
c3
c4
P0
P1
P2
P3
P4
P5
H0
H1
H2
H3
H4
H5
H6
Description
Units
Range
Temperature Set Point 1
Temperature Set Point 2
Set1 and Set2 dependency
Differential for Set1
Differential for Set 2
Band differential
Minimum value for Set1
Minimum value for Set2
Maximum value for Set1
Maximum value for Set2
Operation mode
Alarm differentials
Maximum probe 1 alarm
Maximum probe 2 alarm
Minimum probe 1 alarm
Minimum probe 2 alarm
Alarm check time (*)
Minimum relay stop time
Operation output 1
Operation output 2
Default operation output 1
Default operation output 2
Temperature units
Temp. probe 1 adjustment
Temp. probe 2 adjustment
Decimal point
Probe to be displayed
Number of temp. probes
Set default settings
Keypad protection
Operation led OUT
Operation led def
Communication setup
Access code to parameters
Probe type
Degrees
Degrees
Range
Degrees
Degrees
Degrees
Degrees
Degrees
Degrees
Degrees
Range
Degrees
Degrees
Degrees
Degrees
Degrees
hh:m
Minutes
Range
Range
%ON
%ON
Range
Degrees
Degrees
Option
Option
Range
Command
Option
Option
Option
Numeric
Numeric
Option
r4 to r6
r5 to r7
Ind/dEP
0.1 to 20.0
0.1 to 20.0
0.1 to 20.0
-99.9 to r6
-99.9 to r7
r4 to 302
r5 to 302
On1/On2/nEU
0.1 to 20.0
0.1 to 99.9
0.1 to 99.9
0.1 to 99.9
0.1 to 99.9
0.0 to 18.0
0 to 240
dir/inv
dir/inv
0 to 100
0 to 100
°C/°F
-20.0 to 20.0
-20.0 to 20.0
no/yES
sd1/sd2
1/2
0
no/yES
dir/inv
dir/inv
0 to 999
0 to 999
ptc/pt1
*Time Format: hh:m, where m are tenths of minutes.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Probe Range: -58 to 302°F (-50 to 150°C).
Input: PTC thermistor (10001 @ 25°C), or RTD
(PT1001 @ 0°C).
Outputs: One 8A SPDT relay @ 250 VAC, resistive; One 8A
SPST relay @ 250 VAC resistive; Alarm: TTL 30 mA @ 12 VDC.
Horsepower Rating (HP): 1/3 HP.
Power Requirements: 12 VAC/DC.
Accuracy: 0.5% of full scale.
Display: 3-digit and sign, red.
Resolution: 0.1° (<100°); 1° (*100°).
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 32 to 131°F (0 to 55°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
Dimensions: 76 x 34 x 60 mm (3 x 1.3 x 2.4 in).
Front Panel Rating: NEMA 4X (IP65).
Weight: 2.3 oz (65 g).
Agency Approvals: CE, UR, URC.
MODELS
Model Number
Unit
Input
TSS-40
TSS-41
TSS-60
TSS-61
°F
°C
°F
°C
PTC Thermistor
PTC Thermistor
RTD PT1001
RTD PT1001
ACCESSORIES
TS-5-Probe PVC, 5 ft (1.5 m) cable
TS-51-Probe PVC, 10 ft (3 m) cable
TS-6-Probe metal, 5 ft (1.5 m) cable
TS-61-Probe metal, 10 ft (3 m) cable
APPLICATIONS
TSS Digital Temperature Switches are suitable for industrial chillers,
environmental chambers, walk-ins and freezers, heat sealers, sterilizers, beer and wine chillers, mug frosters, coolers, display cases and
cabinets, warmers, meat and produce storage, floral preservation,
refrigerated transportation, laboratories, food service equipment,
ovens and dryers, tobacco preservation, hot melt glue stitchers for case
erectors, cool rooms, burn-in rooms and chambers, and cold water citrus packing.
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
263
Temperature
Regulate temperatures for heating or cooling control with
Series TSS Dual Stage Temperature Switch. The Series TSS is
designed to accept two inputs (thermistor or RTD) with independent
8A relay output for dual stage temperature control. The unit also features a 30 mA TTL alarm output for activating an external buzzer.
The Series TSS offers 34 programmable parameters to customize control functions. Access to all parameters, except setpoint, can be
secured with a password code. The TSS Series includes a rear terminal cover and instruction manual. Input sensors are sold independently.
Series
TS
Digital Temperature Switch
3-Digit Display, Heating/Cooling Control, 8 or 16 Amp Relay
C
1.34
[34]
1.10
[28]
2.72
[69]
2.95
[75]
Temperature
Panel Cutout 2-51/64 x 1-9/64 (71 x 29)
The TS Digital Temperature Switch is designed to regulate many
heating and cooling applications. Easy programming via the tactile
front keypad enables quick setup of the 12 parameters for simple, reliable operation. The user can define set point, heating/cooling regulation, hysteresis, cycle time, ambient probe adjustment and defrosting
time. The unit features error or alarm messaging and password protection. View probe temperature on the bright red, 3-digit LED display. Select between 8 amp SPDT or 16 amp SPST relay outputs, temperature display in °F or °C, and 110 VAC, 230 VAC, or 12 VDC power
supplies. The Series TS includes a thermistor with 5 ft (1.5 m) cable,
fitting clips for panel mounting, gasket, rear terminal cover, and
instruction manual.
SPECIFICATIONS
Probe range: -58 to 302°F (-50 to 150°C).
Input: 1.5-inch (4 cm) thermistor (10001 @ 25°C) with 5 ft
(1.5 m) cable.
Output: 8A SPDT or 16A SPST relay @ 250 VAC
resistive (Depending on model).
Horsepower Rating (HP): 1/3 HP for 8A and 3/4 HP
for 16A.
Control Type: ON/OFF.
Power Requirements: 110 VAC, 230 VAC or 12 VAC/VDC
(Depending on model). 4VA (230V)
Accuracy: ±1°C.
Display: 3-Digit, red, 1/2˝ digits.
Resolution: 1°.
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 14 to 158°F (-10 to 70°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
Weight: 2.3 oz (65 g).
Front Panel Rating: NEMA 4X (IP65).
Agency Approvals: CE, URc, UR
MODELS
Model Number
Description
TS-13010
TS-13011
TS-13020
TS-13021
TS-13030
TS-13031
TS-83010
TS-83011
TS-83020
TS-83021
TS-83030
TS-83031
110V, 16A, °F
110V, 16A, °C
230V, 16A, °F
230V, 16A, °C
12 VAC/VDC, 16A, °F
12 VAC/VDC, 16A, °C
110V, 8A, °F
110V, 8A, °C
230V, 8A, °F
230V, 8A, °C
12 VAC/VDC, 8A, °F
12 VAC/VDC, 8A, °C
APPLICATIONS
TS Digital Temperature Switches are suitable for industrial chillers,
environmental chambers, walk-ins and freezers, heat sealers, sterilizers, beer and wine chillers, mug frosters, coolers, display cases and
cabinets, warmers, meat and produce storage, floral preservation,
refrigerated transportation, laboratories, food service equipment,
ovens and dryers, tobacco preservation, hot melt glue stitchers for
case erectors, cool rooms, burn-in rooms and chambers, and cold
water citrus packing.
PARAMETERS
SP
r0
r1
r2
d0
d2
d8
c0
c1
P1
H5
t0
264
VISIT OUR WEBSITES:
www.dwyer-inst.com
Range
r1 to r2
1 to 20
-50 to 150°
-50 to 302°F (-50 to 150°C)
Ht/Co
0 to 59 min.
1 to 24 hr.
0 to 59 min.
0 to 24 hr.
-10 to 10
0 to 99 (Set at -00 from factory)
-50 to 302°F (-50 to 150°C)
Units
Degrees
Degrees
Degrees
Degrees
Option
Minutes
Hours
Minutes
Hours
Degrees
Numeric
Degrees
Description
Set point
Differential or hysteresis
Lower Value Set Point
Higher Value Set Point
Heating or Cooling Control
Time for Defrosting
Interval Time between Defrosting
Min. stop time for Load
Continuous Cycle Time
Ambient Probe Adjustment
Parameter Access code
Max. Temp. on Display
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
TSD
Digital Temperature Switch
Heating/Cooling Control, Dual Probe Input, Alarm & Relay Output
C
1.34
[34]
1.10
[28]
2.72
[69]
2.95
[75]
Panel Cutout 2-51/64 x 1-9/64 (71 x 29)
SPECIFICATIONS
ACCESSORIES
TS-5-Probe PVC, 5 ft (1.5 m) cable
TS-51-Probe PVC, 10 ft (3 m) cable
TS-6-Probe metal, 5 ft (1.5 m) cable
TS-61-Probe metal, 10 ft (3 m) cable
(0 to 70°C).
Probe Range: -58 to 302°F (-50 to 150°C).
Input: Two 1.5-inch (4 cm) thermistor (10001 @ 25°C)
with 5-ft (1.5 m) cable.
Output: One 8 amp SPDT relays @ 250 VAC, resistive;
alarm 5mA @ 5 VDC.
Horsepower Rating (HP): 1/3 HP for 8 amp.
Control Type: On/Off.
Power Requirements: 110 VAC, 230 VAC or
12 VAC/DC.
Accuracy: ±0.5% of probe ranges.
Display: 3-Digit, red, 1/2˝ digits.
Resolution: 1°.
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 32 to 158°F
Storage Temperature: -4 to 176°F (-20 to 80°C).
Weight: 6.2 oz (65 g).
Front Panel Protection: NEMA 4X (IP65).
Agency Approvals: CE, UR, UR C .
MODELS
Model
Description
TSD-10110
Dual Probe Input, Single Relay Output and Alarm (110 VAC, °F)
TSD-20110
Dual Probe Input, Single Relay Output and Alarm (230 VAC, °F)
TSD-21110
Dual Probe Input, Single Relay Output and Alarm (230 VAC, °C)
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
265
Temperature
The Series TSD is designed for applications requiring heating
or cooling regulation. The unit includes two probes for temperature regulating and defrost control, an 8 (3) A SPDT relay output, alarm output and digital input.
The temperature switch features up to 48 programmable parameters. The user can define operational parameters such as set
point, differential hysteresis, time delay, and cycle time via the
3-key tactile keypad. To simplify the programming task, 18 preset configurations can be activated by changing a single parameter. Access to all parameters, except the set point, is password protected.
The unit features local indication of the relay output and defrost
status. View ambient or defrosting probe temperature on the
bright red LED display. Error and alarm messages can be
viewed on the display.
The Series TSD includes two probes, gasket, panel clip, snap-on
terminal cover and instruction manual.
Series
TSR
Digital Temperature Switch
Cooling Regulation, Dual Probe, Dual Relay, Alarm
C
1.34
[34]
2.95
[75]
1.10
[28]
2.72
[69]
Temperature
Panel Cutout 2-51/64 x 1-9/64 (71 x 29)
SPECIFICATIONS
The Series TSR Temperature Switch is designed for cooling regulation in refrigeration units. Control compressor operation and electric defrost or hot gas bypass. Dual probe input
permits defrost termination by temperature.
Program 44 different parameters including set point, defrosting cycles, hysteresis, compressor stoppage time, alarms, and
digital input. The digital input allows specialized control for
door open/door closed conditions. Access to all parameters,
except for the set point, are password protected.
View temperature, error messaging, and alarms on the bright
red display. Relay and defrost status are indicated on the front
panel. The Series TSR includes two probes, gasket, mounting
clips, clip on terminal cover, and instruction manual.
Probe Range: -58 to 302°F (-50 to 150°C).
Input: Two 1.5 in (4 cm) thermistor (10001 @ 25°C) with
5 ft (1.5 m) cable.
Output: One 8 amp SPST relay and one SPDT relay @ 250
VAC, resistive; alarm 20 mA @ 12 VDC.
Horsepower Rating (HP): 1/3 HP for 8 amp.
Control Type: On/Off.
Power Requirements: 8-15 VAC/DC.
Accuracy: ±0.5% of probe ranges.
Display: 3-Digit, red, 1/2˝ digits.
Resolution: 1°.
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 32 to 158°F
(0 to 70°C).
ACCESSORIES
TS-5-Probe PVC, 5 ft (1.5 m) cable
TS-51-Probe PVC, 10 ft (3 m) cable
TS-6-Probe metal, 5 ft (1.5 m) cable
TS-61-Probe metal, 10 ft (3 m) cable
Storage Temperature: -4 to 176°F (-20 to 80°C).
Weight: 6.2 oz (65 g).
Front Panel Protection: NEMA 4X (IP65).
Agency Approvals: CE, UR, URC.
MODELS
266
Model Number
Description
TSR-0110
Dual Probe Input, Dual Relay Output and Alarm (12V, °F).
TSR-1110
Dual Probe Input, Dual Relay Output and Alarm (12V, °C).
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
TST
Digital Temperature Switch
Compressor, Defroster & Fan Control, Two Probes
C
1.34
[34]
1.10
[28]
2.72
[69]
2.95
[75]
Panel Cutout 2-51/64 x 1-9/64 (71 x 29)
SPECIFICATIONS
systems using the Series TST Digital Temperature Switch. The unit
Probe Range: -58 to 302°F (-50 to 150°C).
features dual probe input, three SPST relays, alarm output, and digi-
Input: Two 1.5-inch (4 cm) thermistor (10001 @ 25°C)
tal input. The digital input can be configured to control fan and compressor activity or defrost synchronization.
The Series TST offers 48 programmable parameters to optimize sys-
with 5-ft (1.5 m) cable.
Output: Three 8 amp SPST relays @ 250 VAC, resistive;
tem performance. Parameters are password protected for security.
alarm 20mA @ 12 VDC.
The user can define set point, regulation times, fan operation, alarms,
Horsepower Rating (HP): 1/3 HP for 8 amp.
compression cycling, drip time, and many more. The unit offers short
Control Type: On/Off.
cycling protection to avoid hard starts, overload voltages, and unneces-
Power Requirements: 8-15 VAC/DC.
sary equipment wear.
Accuracy: ±0.5% of probe ranges.
Dual probe input permits defrost termination by temperature. The
ambient and defrosting probe temperature can be viewed on the 3-digit
display. Relay, fan or defrost status is indicated by LEDs on the front
Display: 3-Digit, red, 1/2˝ digits.
Resolution: 0.1° (<100°); 1° (>100°).
of the unit. The Series TST includes two probes, mounting clip, gasket,
Memory Backup: Nonvolatile memory.
rear terminal cover, and instruction manual.
Ambient Operating Temperature: 32 to 158°F
(0 to 70°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
ACCESSORIES
TS-5-Probe PVC, 5 ft (1.5 m) cable
TS-51-Probe PVC, 10 ft (3 m) cable
TS-6-Probe metal, 5 ft (1.5 m) cable
TS-61-Probe metal, 10 ft (3 m) cable
Weight: 6.2 oz.
Front Panel Protection: NEMA 4X (IP65).
Agency Approvals: CE, UR, UR C .
MODELS
Model
Description
TST-0110
Dual Probe Input, Triple Relay Output and Alarm (12 VAC, °F)
TST-1110
Dual Probe Input, Triple Relay Output and Alarm (12 VAC, °C)
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
267
Temperature
Regulate a compressor, defroster and fan in refrigeration
Series
DTS
Digital Temperature Switch
Low Cost, 8 amp SPDT or 16 amp SPST Relay
1.34
[34]
1.10
[28]
2.72
[69]
2.95
[75]
Temperature
Panel Cutout 2-51/64 x 1-9/64 (71 x 29)
The DTS Digital Temperature Switch is a low cost unit that performs the functions of more expensive controllers. The switch is
designed for heating or cooling control. Twelve different parameters
can be programmed via the push button front panel. The heating
mode can be used to keep temperature above a user-defined set point
or alert an operator of a low alarm condition. In contrast, the cooling
mode can be used to ensure process temperature stays below the critical level or signal high alarm condition. View temperature, error and
alarm messaging on the bright red, 3-digit LED display. Units accept
PTC probe input (sold separately) and include fitting clips for panel
mounting and instruction manual.
SPECIFICATIONS
Probe Range: -58 to 302°F (-50 to 150°C).
Input: PTC (10001 @25°C).
Output: 8 amp SPDT or 16 amp SPST relay @ 250 VAC
resistive, (Depending on model).
Horsepower Rating (HP): 1/3 HP for 8 amp and 3/4 HP
for 16 amp.
Power Requirements: 110 VAC.
MODELS
Accuracy: ±1°C.
Model Number
Description
DTS-13010
Digital Temperature Switch (110V, 16A, °F)
DTS-13011
Digital Temperature Switch (110 V, 16 A, °C)
DTS-83010
Digital Temperature Switch (110V, 8 A, °F)
DTS-83011
Digital Temperature Switch (110V, 8 A, °C)
Display: 3-Digit, red.
Resolution: 1°.
Ambient Operating Temperature: 14 to 158°F (-10 to 70°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
ACCESSORIES
Weight: 2.3 oz (65 g).
DTS-5 PVC Probe, 5 ft (1.5 m)
Agency Approval: CE.
DTS-52 Metal Probe, 5 ft (1.5 m)
PARAMETERS
SP
r0
r1
r2
d0
d2
d8
c0
c1
P1
H5
t0
268
VISIT OUR WEBSITES:
www.dwyer-inst.com
Range
r1 to r2
1 to 20
-50 to 150°
-50 to 302°F (-50 to 150°C)
Ht/Co
0 to 59 min.
1 to 24 hr.
0 to 59 min.
0 to 24 hr.
-10 to 10
0 to 99 (Set at -00 from factory)
-50 to 302°F (-50 to 150°C)
Units
Degrees
Degrees
Degrees
Degrees
Option
Minutes
Hours
Minutes
Hours
Degrees
Numeric
Degrees
Description
Set point
Differential or hysteresis
Lower Value Set Point
Higher Value Set Point
Heating or Cooling Control
Time for Defrosting
Interval Time between Defrosting
Min. stop time for Load
Continuous Cycle Time
Ambient Probe Adjustment
Parameter Access code
Max. Temp. on Display
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
TI
Temperature Indicator
Low Cost, Two-Digit Display, ±1% Accuracy
1-5/32
[29]
63/64
[25]
2-5/32
[55]
2-7/16
[62]
Panel Cutout 2.36˝ x 1˝ (60 x 26 mm)
Monitor temperature with the Series TI Temperature Indicator. Units
offer a temperature range of -58 to 99°F (-50 to 99°C) with an accuracy of ±1%.
Quickly view temperatures on the bright red, double-digit LED. Models TI-106
& TI-216 feature an external potentiometer for probe temperature adjustment.
The compact design of the Series TI makes it ideal for any refrigeration application.
MODELS
SPECIFICATIONS
Probe Range: -58 to 99°F or -50 to 99°C.
Input: PTC thermistor (10001 @ 25°C), not included.
Power Requirements: 110 VAC or 230 VAC (depending on
model).
Model
Number
TI-10
Power
Supply
110 VAC
TI-21
Display
Adjustable
°F
No
Display: 2-digit plus sign, red, 1/2˝ H digits.
230 VAC
°C
No
Resolution: 1°.
TI-106
110 VAC
°F
Yes
Front Panel Rating: NEMA 4X (IP65).
TI-216
230 VAC
°C
Yes
Weight: 2.3 oz (65 g).
Temperature
Accessory
Accuracy: ±1% FS.
Agency Approvals: UR, CE
DTS-5 PVC Temperature Probe with 5 ft (1.5 m) cable
Series
THC
Temperature/Humidity Switch
Independent Displays, 61 Programmable Parameters, 4 SPST Relays
4-3/32
[104.00]
2-7/16
1-15/16 [61.80]
[49.23]
5
[127.00]
3-7/8
[98.43]
5-9/32
[134.32]
Simultaneously measure and control temperature and humidity with the
Series THC Temperature/Humidity Switch. The unit offers a 3-digit red display
for temperature indication and a 3-digit green display indicating humidity. The
Series THC is equipped with four independent relays, two for temperature control and two relays for humidity control.
The unit offers 61 programmable parameters for temperature and humidity
control including set point, differential, direct/reverse acting, cycle time, alarm
clock time, and decimal point adjustment. In the event of a probe error, the
default operation of the relays can be set to open or close. The THC features
error or alarm messaging and password protection.
The THC Temperature/Humidity Switch accepts up to two temperature probe
inputs (sold separately) and a humidity sensor. A humidity sensor with 0–1V,
0–3V (sold separately), or 4–20 mA output can be used with the Series THC.
MODELS
Model Number
Description
THC-10
°F 110 VAC
THC-11
°C 110 VAC
THC-20
°F 230 VAC
THC-21
°C 230 VAC
ACCESSORIES
THC-P Humidity probe with 3V output & 4 ft (1.2 m) cable
TS-5 Temperature probe, PVC with 5 ft (1.5 m) cable
TS-6 Temperature probe, metal with 5 ft (1.5 m) cable
S-51 Temperature probe, PVC with 10 ft (3 m) cable
TS-61 Temperature probe, metal with 10 ft (3 m) cable
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Measurement Range: Temperature: -58 to 302°F
(-50 to 150°C); Humidity: 0 to 100%RH.
Input: Up to 2 thermistors and 1 humidity sensor.
Output: 4 SPST, 8A relays @ 250 VAC.
Horsepower Rating (HP): 1/3 HP.
Control Type: ON/OFF direction, direct or reverse acting,
neutral.
Power Requirements: 110 or 230 VAC (depending on
model).
Accuracy: Temperature:±0.5% of probe range; Humidity:
±3% of range.
Display: Two 3-digit displays. 1/2˝ digits.
Resolution: 0.1°.
Memory Backup: Nonvolatile memory.
Ambient Operating Temperature: 32 to 158°F (0 to 70°C).
Storage Temperature: -4 to 176°F (-20 to 80°C).
Weight: 1.17 lb (530 g).
Panel Cutout: 5.15˝ x 2.37˝ (131 x 111mm).
Front Panel Protection: NEMA 4X (IP65).
Agency Approvals: CE.
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
269
Temperature/Process Controller
Model
32DZ
1/32 DIN, Dual Zone Control, Fuzzy Logic, Self-Tune® PID
4.395
[111.60]
RTD
OPTIONS OUT A
&
3
4
5
6
7
8
9
10 11 12
0.870
[22.10]
1.184
[30.10]
0.25 [6.35]
MAX. PANEL THICKNESS
2
Temperature
2.080
[52.80]
OUT B
AL
T/C
1V 2
0.433
[11.00]
STANDARD FEATURES
• Large Dual Display
• Independent Self-Tune for Each Zone
• Independent Fuzzy Logic for Each Zone
•
•
•
•
The Model 32DZ temperature/process controls set a new stan-
SPECIFICATIONS
dard in 1/32 DIN power, flexibility, and value. Love Controls is proud
Inputs: Thermocouple, Type J, K, E, L, and N.
to be the creator of the world’s first dual zone control in the 1/32 DIN
Display: Two 4-digit, 7 segment, 0.259 high (6.35 mm) LEDs.
size. Ease of use is assured from the creators of the world’s first dual
Loop Break Protection
Peak/Valley Indication
Illuminated Keypad
Four Password Protected Security Levels
Accuracy: ±0.25% of span, ±1 least significant digit.
display 1/32 DIN temperature /process control. The 32DZ offers 5
thermocouple type inputs. Each zone offers a single set point with
Supply Voltage: 100 to 240 VAC, nominal, +10 - 15%, 50 to 400
Hz. single phase; 132 to 240 VDC, nominal, +10 - 20%.
mechanical relay. Standard features include independent Fuzzy Logic,
Power Consumption: 5 VA maximum.
Selftune®, and Peak/Valley indication for each zone. Process protec-
Operating Temperature: 14 to 131°F (–10 to 55°C).
tion is provided by open sensor protection, shorted sensor protection,
Memory Backup: Nonvolative memory. No batteries required.
input rate of change protection, and loop break protection. Options for
Control Output Ratings:
the 32DZ include RS-485 Serial Communication. Designed and built
Relay: SPST, 3A @ 240 VAC resistive; 1.5A @ 240 VAC inductive; Pilot Duty Rating: 250 VA, 2A @ 120 VAC or 1A @ 240
VAC.
in the USA, the 32DZ offers the highest levels of features, function,
and quality available today.
Weight: 4 oz (114 g).
INPUT RANGES
Model 32DZ1133 Temperature Control
INPUT TYPE
RANGE °F
RANGE °C
Type J or L1 Thermocouple
-100 to +1607
-73 to +871
Type K Thermocouple
-200 to +2500
-129 to +1371
Type E1 Thermocouple
-100 to 1800
-73 to +932
-100 to +2372
-73 to +1300
1
Options
992, RS-485 Serial Communications. Allows remote computer to
read and write all control parameters
1
Type N Thermocouple
1
These Input Types can be set for 0.1° display. If temperature goes above 999.9° or less than -199.9° the display will return to whole degree resolution.
270
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Temperature Controller/Process
Series
32A
1/32 DIN, Universal Input, Self-Tune®, Fuzzy Logic
4.395
[111.60]
RTD
OPTIONS OUT A
&
3
4
5
6
7
8
9
10 11 12
0.870
[22.10]
1.184
[30.10]
0.25 [6.35]
MAX. PANEL THICKNESS
2
•
•
•
•
•
•
The 32A Series temperature/process controllers set
a new standard in 1/32 DIN power, flexibility and value. This
group of controls offers the highest level of features in the
most compact industry standard size. Ease of use is assured
with the world’s first dual display 1/32 DIN temperature/
process controllers.
The Series 32A offers universal input (10 thermocouple types,
4 RTD types, voltage and current), single or dual set point,
alarm (optional), Fuzzy Logic, Self-Tune®, Peak/Valley indication, Percent Output indication and Heater Break protection. Auto/Manual capability and 16 Segment Ramp and Soak
with adjustable time base are also offered. Process protection
features include open sensor protection, shorted sensor protection, input rate of change protection and loop break protection.
SPECIFICATIONS
MODELS
Temperature
STANDARD FEATURES
• Large Dual Display
• Self-Tune®
• Fuzzy Logic
• Universal Input
• Loop Break Protection
Model No.
32A020
32A123
32A133
2.080
[52.80]
OUT B
AL
T/C
1V 2
0.433
[11.00]
Peak/Valley Indication
Percent Output Indication
Illuminated Keypad
16 Segment Ramp/Soak Function
Auto/Manual Station Function
Four Password Protected Security Levels
Selectable Inputs: Thermocouple, RTD, DC Voltage or DC Current
selectable.
Display: Two 4-digit, 7 segment, 0.25⬙ high (6.35 mm) LEDs.
Accuracy: ±0.25% of span, ±1 least significant digit.
Supply Voltage: 100 to 240 VAC, nominal, +10 - 15%, 50 to 400 Hz.
single phase; 132 to 240 VDC, nominal, +10 - 20%.
Power Consumption: 5 VA maximum.
Operating Temperature: 14 to 131°F (–10 to 55°C).
Memory Backup: Nonvolatile memory. No batteries required.
Control Output Ratings:
Relay: SPST, 3A @ 240 VAC resistive; 1.5A @ 240 VAC inductive;
Pilot Duty Rating: 250 VA, 2A @ 120 VAC or 1A @ 240 VAC.
Switched Voltage (Non-isolated): 5 VDC @ 20 mA.
Weight: 4 oz (114 g).
Agency Approvals: CE, UL E83725.
Front Panel Rating: Type 4X (IP66).
OPTIONS
Alarm
No
Yes
Yes
CALL TO ORDER:
Output A
5 VDC
5 VDC
Relay
U.S. Phone 219 879-8000
Output B
None
Relay
Relay
•
992, RS 485 Computer Compatible Control
9502, 12-24 VDC/VAC Power Input
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
271
Series
16A
Temperature Controller/Process
®
1/16 DIN, Universal lnput, Fuzzy Logic, Self-Tune® PID
5.24 [133]
0.45
[11.4]
1.89
[48]
1.76
[44.7]
Temperature
PANEL CUT-OUT: 1.77 +0.02 [45 +0.6] SQUARE
Latest microprocessor based technology affords full programmability with complete array of features in compact ultralow cost unit.
16A Series Temperature/Process Controller features universal input,
Self-Tune® PID, Fuzzy Logic, and dual four-digit LED displays for
process and set point value. Selectable inputs can be thermocouple,
RTD, current or voltage. Available outputs are solid-state relay, relay,
pulsed voltage, or proportional current. Programmable alarm (optional) can be reset automatically or manually. Front panel is waterproof
and corrosion resistant (UL type 4-X), making it ideal for sanitary
applications. Replace electronics without wiring changes (via removable front panel). Self diagnostics, nonvolatile memory and selectable
control modes are all designed for greater productivity. Four security levels are password protected. On-off, P, PI or PID manual tune
control functions can be selected or the controller will Self-Tune® automatically for best PID control.
0.25 [6.35]
MAX. PANEL THICKNESS
SPECIFICATIONS
Selectable Inputs: Thermocouple, RTD, DC Voltage, or DC
Current (See Input Ranges).
Display: Two four-digit LED displays, 0.3 in (7.62 mm) high.
Display Resolution: 1 degree or 0.1 degree (sensor dependent),
or 1 count.
Accuracy: ±0.25% of span ±1 least significant digit.
Supply Voltage: 100 to 240 VAC nominal, +10% -15%, 50 to
400 Hz single phase; 132 to 240 VDC +10% -20%.
Operating Temperature: 14 to 131°F (-10 to 55°C).
Power Consumption: 5 VA maximum.
Control Output Ratings:
SSR: 2.0 A at 240 VAC resistive at 77°F (25°C). De-rates to
1.0 A at 130°F (55°C). Minimum load of 100 mA. DC SSR: 1.75 A
at 32 VDC maximum. Relay: SPST, 3A at 240 VAC resistive, 1.5 A
@ 240 VAC inductive. Pilot Duty rating: 250 VA, 2 A @ 120 VAC, 1
A @ 240 VAC. Alarm Relay: SPST, 3 A @ 240 VAC resistive; 1.5
A @ 240 VAC inductive. Pilot Duty Rating: 240 VA, 2 A @ 120 VAC
or 1 A @ 240 VAC. Switched Voltage: 15 VDC at 20 mA.
Proportional Current: 0 to 20 mADC, scalable, into 600 ohms
maximum.
Weight: 8 oz (227g).
Agency Approvals: UL E83725, CE.
Front Panel Rating: Type 4X (IP66).
Serial Communications (Optional): RS-232 or RS-485 with
either LoveLink™ or Modbus® RTU protocol.
The 16A2 offers the best value in Standard Features in a Process and
Temperature control. In addition to the features listed above, the
16A2 offers Peak/Valley indication, Percent Output indication, Digital
Input Filter, and a host of others.
OPTIONS
MODELS
MODEL NO.
ALARM
OUTPUT A
OUTPUT B
16A2111
16A2030
16A2133
16A2130
16A2020
16A2110
16A2050
Yes
No
Yes
Yes
No
Yes
No
SSR
Relay
Relay
Relay
15 VDC
SSR
Current
SSR
None
Relay
None
None
None
None
934**, Process Signal Output, PV or SV.
Isolated 0 to 20 mADC
936**, Process Signal Output, PV or SV.
Isolated 0 to 10 VDC
992**, RS 485 Computer Compatible Control
LovelinkTM Protocol
993**, RS 232 Computer Compatible LovelinkTM Protocol
9502, 12-24 VDC/VAC power input
** These options may not be combined with each other.
Modbus® is a registered trademark of Schnieder Automation.
272
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
16L
Limit
Controls
FM Approved, Large, Dual Display, Universal Input
5.24" (133)
1.76"
(44.7)
0.45"
(11.4)
1.89"
(48)
All dimensions in inches (millimeters).
Panel cut out is 1.77 +0.02" (45 +0.6) square.
0.25" (6.35)
Max. Panel Thickness
Selectable Inputs: 10 Thermocouple, 4 RTD, DC Voltage,
or DC Current selectable.
Display: Two 4 digit, 7 segment 0.3˝ (7.62 mm) high LEDs.
Accuracy: ±0.25% of span, ±1 least significant digit.
Supply Voltage: 100 to 240 VAC, nominal, +10 -15%, 50
The 16L Series Temperature/Process FM Approved Limit
Controls set a new standard in 1/16 DIN Limit controls. The 16L
offers universal input (10 thermocouple types, 4 RTD types, voltage,
and current), single set point or dual set point. Standard features include Remote Reset capability, Peak/Valley indication, open sensor
protection, input rate of change protection, and much more.
Unit offers 1500 VAC resolution, selectable high or low input, programmable sensor break protection and adjustable differential.
to 400 Hz. single phase; 132 to 240 VDC, nominal,
+10 -20%.
Power Consumption: 5 VA maximum.
Operating Temperature: +14 to 131˚F (-10 to +55˚C).
Memory Backup: Nonvolatile memory. No batteries
required.
Outputs include normally open (form A) and normally closed (form
B) relays. Form A and form B relays can be setup one for each set
point output and logically linked to emulate a form C output.
Designed and built in the USA, the 16L family of controls offers the
highest levels of features, function, and quality available today.
Control Output Ratings: Relay: SPST, 3A @ 240 VAC
resistive; 1.5A @ 240 VAC inductive.
Weight: 8 oz (227 g).
Agency Approvals: UL, FM.
MODELS
Model No.
16L2030
16L2034
Output A
N.O. Relays
N.O. Relays
Output B
None
N.C. Relays
OPTIONS
934, Process Signal Output, PV or SV. Isolated 0 to 20 mADC
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
273
Temperature
SPECIFICATIONS
STANDARD FEATURES
• FM Approved Limit
• Large Dual Display
• Universal Input
• Dedicated, Illuminated Reset Key
• Remote Reset Capability Standard
• Four Password Protected Security Levels
Series
1500
Temperature Controller
1/16 DIN, Microprocessor Based, Self-Tune® PID
®
®
4.925 [125]
4.475 [114]
1.880
[48]
1.760
[45]
.450 [12]
* .125 [3]
Temperature
PANEL CUTOUT FOR ALL MODELS 1.772" X 1.772" [45 mm X 45 mm]
ALLOW FOR 0.5" [13 mm] CLEARANCE AT THE REAR OF INSTRUMENT.
The Love Series 1500 Temperature Controller is a reliable, ac-
SPECIFICATIONS
curate and fully programmable temperature control or alarm in an
Inputs: Thermocouple (J type stocked), field selectable K, T, E, or
economical 1/16 DIN case. Microprocessor based, all control func-
N type; RTD (100Ω DIN).
tions are easily programmed from the waterproof, corrosion resis-
Display: 4 digit, 7 segment 0.3" high LED display; Set Point and
tant front panel. Models are available that accept field selectable J, K
Alarm status LED indicators; °F or °C LED indicators.
or T type thermocouples or RTD 100Ω DIN (.00385 ohms/ohm/°C) in-
Accuracy: ±0.25% of span ±1 least significant digit.
Supply Voltage: 100 to 240 VAC, 50 – 400 Hz. single phase; 132
puts and provide SSR, Relay or 5 VDC Logic outputs. All models are
to 240 VDC (nom.) +10% – 20%. 5 VA maximum power
programmable for on-off, P, PI, manual PID or automatic Self-Tune®
consumption.
PID control. Like the control output, optional alarm is field config-
Temperature Range: Operating 14 to 131°F (-10 to 55°C);
urable direct acting (cooling) or reverse acting (heating) and is easily
storage -40 to 176°F (-40 to 80°C).
adjusted for either automatic or manual reset to provide independent
Output Ratings: SSR: 3.5A @ 240 VAC max. @ 77°F (25°C)
high or low system protection. Four security levels are password pro-
typical. Relay (SPST): 3A res., 1.5A ind. @ 250 VAC; Pilot Duty =
tected.
250 VA, 2A @ 125 VAC or 1A @ 250 VAC.
Alarm Rating (optional): Relay (SPST): 3A res., 1.5A ind. @ 250
VAC.
Isolation: Relay and SSR outputs are isolated.
Sensor Break Protection: De-energizes control output.
MODELS
Model
Input
Output
Alarm
15011
15111
15013
15113
15023
15123
Thermocouple
Thermocouple
Thermocouple
Thermocouple
RTD (DIN)
RTD (DIN)
SSR
SSR
Relay
Relay
Relay
Relay
No
Yes
No
Yes
No
Yes
Weight: 8 oz (227 g).
R/C Snubber: Recommended for solenoid or contactor loads. Order
optional Part Number A-600.
No. A-600, R/C Snubber — For solenoid or contactor loads
274
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
8500
Temperature/Controller
1/8 DIN, Fully Programmable, Self-Tune® PID
Model 85000-0 shown. Model 85000-1 same
except height and width are reversed. Panel cutout
for both styles 1.772" X 3.622" (45 X 92 mm).
85000-0
A water and corrosion resistant front panel (NEMA 4X, IP65), input
fault timer, digital input filter, Self-Tune® ramp to setpoint, four password protected security levels and °F or °C display selection are all
standard. Entire electronics package is easily field replaceable without wiring changes thanks to the removable front panel.
MODELS
Model
Number
Input
85111-0
Output
Thermocouple
SSR
85112-0
Thermocouple
5 VDC
85113-0
Thermocouple
Relay
85115-0
Thermocouple
4-20 mA
85121-0
RTD
SSR
85122-0
RTD
5 VDC
85123-0
RTD
Relay
RTD
4-20 mA
85125-0
Panel-Maximum panel thickness
0.25" (6.53 mm)
SPECIFICATIONS
Inputs: Thermocouple or RTD.
Display: Two 4 digit, 7 segment LED; models; 0.3" (7.62 mm) high.
Resolution: 1 degree or 0.1 degree.
Accuracy: ±0.25% of span, ±1 degree.
Supply Voltage: 100 to 240 VAC nominal, +10%-15%, 50-400 Hz, single
phase; 132-240 VDC nominal, +10%-20%.
Power Consumption: 5 VA maximum.
Operating Temperature: 14 to 131°F (-10 to 55°C).
Memory Backup: Non-volatile memory. No batteries required.
Control Output Ratings:
SSR: 2.5A @ 240 VAC resistive at 77°F (25°C).
De-rate to 1.25A @ 130°F (55°C)
Relay: SPDT,10A @ 240 VAC resistive.
Alarm Relay: SPST, 3A @ 240 VAC resistive.
Switched Voltage (non-isolated): 5 VDC @ 20 mA.
Proportional Isolated Current: 0-20 m A, selectable, into
600 ohms maximum.
Control Action: Selectable for Reverse (usually heating) or Direct (usually
cooling).
Ramp: One ramp time adjustable from 0 to 100 hours.
Isolation: Relay and SSR outputs; 1500 VAC. 0-20 mA output; 500 VAC.
5 VDC output is not isolated.
Weight: 13 oz (369 g)
*When ordering a control to operate contactor or solenoid loads greater than
100 mA, select the SSR output instead of the Relay. If the relay is selected,
order part number A-600. R/C snubber
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
275
Temperature
The Love Series 8500 Temperature/Process Control provides
an impressive selection of features in a compact, economical 1/8 DIN package. Features include on-off, time proportioning, proportional, PI, PD or
full PID control — fully programmable from the front panel — or use SelfTune® PID. Inputs are selectable from a variety of thermocouple types including J, K, T, E, N or L; DIN NIST or Ni RTD’s. Output choices include
solid state relay, mechanical relay, 5 VDC — ideal for driving an external
SSR — or isolated 4-20 mA proportional current. An optional programmable alarm provides a full array of alarm action configurations including
high alarm, low alarm and high/low guardband alarm. Manual reset,
power-up inhibit and power interrupt reset provide additional alarm flexibility.
®
Series
8600
Temperature/Process Controller
1/8 DIN Self-Tune® PID, Fuzzy Logic Software
®
1.934
[49.10]
4.500 [114.3]
.530 [13.5]
3.774
[95.9]
3.596
[91.3]
Model 86000-0 shown. Model 86000-1 same
except height and width are reversed. Panel cutout
for both styles 1.772" X 3.622" (45 X 92 mm).
Temperature
86000-0
Series 8600 Temperature/Process Controllers set a new
standard for quality, ease-of-use and value. While a high level of
standard features are included, many function setup items appear in the control menu only when the function is selected, so
you don’t have to wade through unnecessary items. Units feature a universal input for thermocouple types J, K, E, T, L, N,
B, C, S, & R; RTDs — 100Ω Plt. NIST, 100Ω Plt. DIN, 120Ω Ni
Industrial, 1000Ω Plt. DIN; differential input (-10 to +10 mV
DC) and process input (0 to 20 mA DC, 0 to 10 VDC). A standard 24 volt isolated, regulated power supply is included to
operate most standard 4-20 mA transmitters.
Standard features include Self-Tune®, Fuzzy Logic, fully adjustable PID, Auto/Manual control with bumpless transfer and
front panel activation key, percent output indication, peak and
valley indication, loop break protection and indication. For
process inputs, the display is fully programmable from
-1999 to +9999 with selectable decimal point location. Most
thermocouple and RTD inputs can show whole or tenth degree
displays. The Series 8600 is available with single or dual setpoint outputs and can be programmed for on-off, PID or
heat/cool or latching alarm. All outputs are isolated from the
inputs. Outputs include 10 amp relay, 2.5 amp SSR and 0-20
mA DC (scalable). 15 VDC SSR drive is standard.
More Standard Features
❑ NEMA 4X (IP 65) Front Panel Resists Dust & Moisture
❑ Four Password Protected Security Levels
❑ Front Panel Programmability
❑ 16 Segments of Ramp/Soak with Program End Control
❑ Operates on 100-240 VAC, 132-240 VDC
SPECIFICATIONS
Selectable Inputs: Thermocouple, RTD, DC voltage or DC current.
Input Impedance:
Thermocouple — 3 megohms minimum.
Voltage — 5000 ohms.
Current — 10 ohms.
RTD Current — 200µA maximum.
Display: Two 4 digit, 7 segment LED; 0.4" (10 mm) high — horizontal
models; 0.3" (7.62 mm) high — vertical models.
Accuracy: ±0.25% of span, ±1 least significant digit.
Supply Voltage: 100 to 240 VAC nominal, +10%-15%, 50 to 400 Hz,
single phase; 132 to 240 VDC +10%-20%.
Operating Temperature: 14 to 131°F (-10 to 55°C).
Control Output Ratings:
SSR: 2.5 A at 240 VAC resistive at 77°F (25°C). De-rate to 1.25 A
at 130°F (55°C).
Relay: SPDT,10 A at 240 VAC resistive,1⁄2 hp at 120 VAC, 1⁄3 hp at
240 VAC.
Alarm Relay: SPST, 3 A at 240 VAC resistive.
Switched Voltage: 15 VDC at 20 mA.
Proportional Current: 0-20 mA DC, scalable into 600 ohms
maximum.
Weight: 13 oz (369 g).
MODELS
Model
Number
Output A
Output B
86111-0
SSR
SSR
86120-0
15 VDC Pulsed
None
86133-0
Relay
Relay
86153-0
0-20 mA
Relay
276
VISIT OUR WEBSITES:
www.dwyer-inst.com
Panel-Maximum panel thickness
0.25" (6.53 mm)
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Temperature/Controller
Series
2500
1/4 DIN Fully Programmable, Self-Tune® PID
4.500 [114.3]
®
3.774 [95.9]
.530
[13.5]
3.774
[95.9]
3.596
[91.3]
Panel Max. Thickness
.250 [6.35]
The Love Series 2500 Temperature Control provides an im-
SPECIFICATIONS
pressive array of features in an economical 1/4 DIN package. Fea-
Inputs: Thermocouple or RTD.
Input Impedance: Thermocouple = 3 megohms minimum, RTD current =
200 µA maximum.
Display: Two-4 digit, 7 segment, 0.56" high LED. Resolution: 1 degree or
0.1 degree.
Accuracy: ±0.25% of span, ±1 degree.
Supply Voltage: 100-240 VAC nominal, ±10%, 50-400 Hz, single phase;
132-240 VDC nominal, ±10%.
Power Consumption: 5 VA maximum.
Operating Temperature: 14 to 131°F (-10 to 55°C).
Memory Backup: Non-volatile memory. No batteries required.
Control Output Ratings:
SSR: 2.5A @ 240 VAC resistive at 77°F (25°C). De-rates to 1.25A
@ 130°F (55°C).
Relay: SPDT, 10 A @ 240 VAC resistive.
Switched Voltage (non-isolated): 5 VDC @ 20 mA.
Proportional Isolated Current: 0-20 mA, selectable, into 600
Ohms maximum.
Control Action: Selectable for reverse (usually heating) or direct (usually
cooling).
Ramp: One ramp time adjustable from 0-100 hours.
Isolation: Relay and SSR outputs; 1500 VAC. 0-20 mA output; 500 VAC.
5 VDC output is not isolated.
Weight: 13 oz (369 g).
Front Panel Rating: NEMA 4X (IP65).
tures include on-off, time proportioning, proportional, PI, PD, or full
PID control, programmable from the front panel, or use Self-Tune®
PID. Input types are selectable from a variety of thermocouple types (J,
K, T, E, N or L) or DIN, NIST or Ni RTD’s. Outputs include solid state
relay, mechanical relay, 5 VDC (ideal for driving an external SSR) or
isolated 4-20 mA proportional current. Programmable alarm can act as
high or low or high/low guardband alarm.
A water and corrosion resistant front panel (NEMA 4X; IP 65), input
fault timer, digital input filter, Self-Tune® ramp to setpoint, four password protected security levels and °F or °C display selection are all
standard. Entire electronics package is field replaceable without wiring
changes thanks to removable front panel.
MODELS
MODEL NO.
ALARM
INPUT
OUTPUT*
25111
25112
25113
25115
25125
Yes
Yes
Yes
Yes
Yes
Thermocouple
Thermocouple
Thermocouple
Thermocouple
RTD
SSR
5 VDC
Relay
4-20 mA
4-20 mA
*When ordering a control to operate contactor or solenoid loads greater than
100 mA, select the SSR output instead of the Relay. If the Relay is selected,
also order P/N A-600 R/C Snubber.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
277
Temperature
Panel Cutout: 3.622" x 3.622" (92 mm x 92 mm)
Depth Behind Mounting Surface: 4" (103 mm)
Series
2600
Temperature/Process Controller
1/4 DIN Self-Tune® PID, Fuzzy Logic Software
4.500
[114.3]
®
3.774
[95.9]
.530
[13.5]
3.774
[95.9]
3.596
[91.3]
Temperature
Max. Panel Thickness 0.25[6.53]
More Standard Features
Series 2600 Temperature/Process Controllers set a new standard for quality, versatility, ease-of-use and value. While they include
a high level of standard features, many function setup items appear
in the control menu only when the function is selected, so you don’t
have to wade through unnecessary items. Units feature a universal
input for thermocouple types J,K,E,T,L,N,B,C,S & R; RTDs 100Ω Plt.
NIST, 100Ω Plt. DIN, 120Ω Ni Industrial, 1000Ω Plt. DIN; differential
input (-10 to +10 mV DC) and process input (0 to 20 mA DC, 0 to 10 VDC).
A standard 24 Volt isolated, regulated power supply is included to operate most standard 4-20 mA transmitters.
❑ NEMA 4X (IP65) Front Panel Resists Dust & Moisture
❑ Four Password Protected Security Levels
❑ Front Panel Programmability
❑ 16 Segments of Ramp/Soak with Program End Control
❑ Operates on 100-240 VAC, 132-240 VDC
SPECIFICATIONS
Selectable Inputs: Thermocouple, RTD, DC voltage or DC current.
Input Impedance:
Thermocouple — 3 Megohms minimum.
Voltage — 5000 ohms.
Current — 10 ohms.
RTD Current — 200 µA maximum.
Display: Two 4 digit, 7 segment, 0.56" (14.2 mm) high LED.
Accuracy: ±0.25% of span, ±1 least significant digit.
Supply Voltage: 100 to 240 VAC nominal, +10%-15%, 50 to 400 Hz,
single phase; 132 to 240 VDC +10% -20%.
Operating Temperature: 14 to 131°F (-10 to 55°C).
Control Output Ratings:
Relay: SPDT,10A @ 240 VAC resistive,1⁄2 hp at 120 VAC,
1
⁄3 hp @ 240 VAC.
Alarm Relay: SPST, 3A at 240 VAC resistive.
Proportional Current: 0-20 mA DC, scalable into 600 ohms
maximum.
Weight: 13 oz (369 g).
Front Panel Rating: NEMA 4X (IP65).
Standard features include Self-Tune®, Fuzzy Logic, fully adjustable
PID, Auto/Manual control with bumpless transfer and front panel activation key, percent output indication, peak and valley indication,
loop break protection and indication. For process inputs, the display
is fully programmable from -1999 to +9999 with selectable decimal
point location. Most thermocouple and RTD inputs can show whole or
tenth degree displays. The Series 2600 is available with single or dual
setpoint outputs and can be programmed for on-off, PID or heat/cool
or latching alarm. All outputs are isolated from the inputs. Outputs include 10 Amp relay, and 0-20 mA DC (scalable).
MODELS
Model No.
Alarm
Output A
Output B
26130
26150
26133
Yes
Yes
Yes
Relay
Current
Relay
None
None
Relay
OPTIONS
934, Process Signal Output, PV or SV,
Isolated 0 to 20 mADC
278
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
A-900
&
A-901
1/4 DIN Control Enclosures
Weatherproof, Durable, Pre-Cut Mounting Hole
A-900
®
A-901
4-1/4
[107.95]
10-32 UNF-28
TYP 8 PLCS
3-39/64
[91.68]
1-1/2
[38.10]
1-3/4
[44.45]
Temperature
4-11/64
[105.97]
5-1/64
[127.40]
3-39/64 4-1/4 7-11/16
[91.68] [107.95] [195.26]
A-901 UNIT
(4-1/2 [114.30] STANDOFFS)
4 PLCS
7-11/16
[195.26]
5-1/64
[127.40]
TOP VIEW
Models A-900 and A-901 are the perfect instrument housing for
indoor or outdoor applications. Protects controls from dirt, dust, oil
and water. Unit is rated weatherproof type NEMA 4X and has a fully
gasketed cover. Standard features include a lockable latch to prevent
tampering and flush mounting hardware.
The Model A-900 comes standard with a 1/4 DIN cut out in the front
cover. Controller will mount with front face exposed for easy access to
the programming buttons. Love and Mercoid controllers feature
weatherproof NEMA 4X rated front panels and gaskets enabling the
control to be weatherproof protected when installed in the A-900 even
though the front face is exposed. Wiring an installed control is easy
due to the hinged cover and spacious clearance for the control to swing
out with front cover. The lockable latch prevents unauthorized removal
of the control from the enclosure.
The Model A-901 comes standard with a clear plastic front window and
mounting hardware to install the control inside the box. Controller
mounts just behind the window assuring easy viewing. Mounting the
control inside the enclosure protects the control face from corrosive
atmospheres or from being covered in oil, dirt and dust. The lockable
latch prevents unauthorized removal of the control and removes access
to the control programming buttons. The Mounting hardware is
attached to the rear of the enclosure and includes a bracket with a 1/4
DIN cutout and standoffs long enough for Love and Mercoid controls
to fit. Control programming buttons are easily accessible by just opening the front cover.
FEATURES
• UV stabilized for outdoor use.
• Snap latch with lockable hasp.
• Continuous cover hinge.
• Fiberglass material is easily punched or drilled for conduit
connections.
• Includes feet and screws for flush mounting to a wall.
• Compatible with Love 2500, 2600, LCU204, LCU104, and
Mercoid MPC.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SIDE VIEW
BOTTOM VIEW
SPECIFICATIONS
Service: Indoor or outdoor.
Rating: NEMA 1, 2, 3, 3R, 4, 4X, 12 and 13.
Materials:
Body: UV stabilized fiberglass reinforced polyester.
Snap Latch: 304 SS.
Hinge: Stainless Steel.
Mounting Feet and Screws: 304 SS.
Window: UV stabilized polycarbonate.
Cover Gasket: Neoprene.
Agency Approvals: UL 508.
Control Temperature Limits:
When using the enclosures with controls that have 10A relay outputs the extra heat generation decreases the maximum ambient
temperature value that the control can be used at inside the enclosure. Other outputs on our controls are not a concern.
For Models: 25XX3, 26XX3, 26X3X, 26X33, MPC
Maximum Current
A-901
A-900
10 Amps
10 Amps
9 Amps
10 Amps
6 Amps
7.5 Amps
Ambient
Temperature
77°F (25°C)
104°F (40°C)
131°F (55°C)
MODELS
Model
Number
A-900
Description
Weatherproof enclosure, Type 4X. Control
direct panel mounts in the front of the
enclosure.
Weatherproof enclosure, Type 4X. Clear
plastic window with rear panel for mounting
the control inside the enclosure.
A-901
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
279
Series
1400
Analog Setpoint Temperature Controller
1/16 DIN, Compact & Low Cost
®
®
.400 [10.2]
4.925 [125]
[48]
4.475 [114]
1.880
[48]
1.760
[45]
.450 [12]
*0.125 [3]
Temperature
Panel cutout for all models 11.772˜ x 1.772˜ [45 mm x 45 mm]
allow for 0.5˜ [13 mm] clearance at the rear of instrument.
*Present for all outputs other than relay
The Love Series 1400 Temperature Controller is a reliable,
SPECIFICATIONS
accurate and ultra-low cost analog control or alarm in a compact
Inputs: Type J and K thermocouple or RTD.
1/16 DIN case. LED status and deviation indication, analog setpoint
Accuracy: ±2% full scale.
indicator and dual °F/°C scale are standard features. Inputs include
Supply Voltage: 100 to 240 VAC, 50-400 Hz.
J and K type thermocouples or RTDs. Control outputs are available
Operating Temperature: 14 to 130°F (-10 to 55°C); storage -13
as either On/Off, Time Proportioning Relay, or 5VDC Logic reverse
to 149°F (-25 to 65°C).
acting (heating). Alarm output is field configurable reverse acting
Output Ratings: Relay (SPST): 3A res., 1.5A ind. @ 250 VAC;
(heating) or direct acting (cooling) and easily adjusted for either au-
Pilot Duty = 250 VA, 2A @ 125 VAC or 1A @ 250 VAC. Logic (non-
tomatic or manual reset to provide independent high or low sys-
isolated): 5 VDC @ 25 mA max. Recorder: 0-1 VDC @ 0-1 mA.
tem protection. Electronics are easily replaceable via removable
Deviation Indicator: LEDs indicate process value deviation from
front panel (just pull out — no wiring changes). Front panel meets
setpoint of greater than 1.5% full scale.
NEMA-2 and NEMA-12.
Input Impedance: Thermocouple (3 megohms min.) RTD current
MODELS
Model
Number
140AA
140JC
140AC
140BC
140JA
140EF
(500 µA max.).
Input
J
Thermocouple
J
Thermocouple
J
Thermocouple
J
Thermocouple
J
Thermocouple
K
Thermocouple
Range
0-400°F
(210°C)
0-800°F
(420°C)
0-800°F
(420°C)
0-800°F
(420°C)
0-400°F
(210°C)
0-800°F
(420°C)
Weight: 8 oz (227 g).
Output
Time Proportioning
Relay
Alarm Relay
APPLICATIONS
Plastics extrusion; injection, compounding, screening, or thermoforming machinery; package sealing equipment; industrial bonding, paint application, glass manufacturing, heat treating;
laboratory ovens and environmental chambers; food preparation
equipment; valves, motors, HVAC, chillers, incinerators.
Time Proportioning
Relay
On/Off Relay
Alarm Relay
Time Proportioning
Relay
OPTIONS
210, Setpoint Knob Lock - not available with Aux. Alarm
215, Alarm Power Interrupt (Automatic reset on power on)
2102, FM Approved Setpoint Knob-Lock. Not available with Aux. Alarm
280
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Model
60
Low Cost Analog Thermostat Temperature Control
On/Off Control, Local Setpoint Adjustment
4.6 (0.180) DIA.
(0.250 DIA. SHAFT
WITH 0.180 FLAT
AS SHOWN
3.4 (0.135) DIA.
LOCATING
TAB
DIA.14.7 (0.578)
OPENING
FOR SHAFT
63.5 (2.500)
32.4 (1.275)
14.6
(0.875)
13.5
(.531)
44.5 (1.750)
52.0 (2.050)
88.9 (3.600)
4.6 (0.180) DIA.
MOUNTING
HOLES (4 PLACES)
Skirted Knob
21.3
(0.840)
17.8
(0.700)
LOCATING TAB
3.4 (0.135) DIA.,
3.8 (0.150) HIGH
22.4 (0.88)
13.6
(0.535)
6.4 (0.250)
3.7 (1.440)
35.6 (1.400)
NOTE: All dimensions in millimeters with inches in parenthesis
78.2 (3.080)
SPECIFICATIONS
cal, reliable, solid state, temperature control with an accuracy of better
Supply Voltage: 120 or 240 VAC + 10%, - 15%; 50/60 Hz.
than 1%. The control electronics are packaged in a rugged panel-mount
Temperature
The Love Controls Model 60 Analog Thermostat is an economi-
Output: SPST normally open relay: 10 A @ 120/240 VAC resis-
enclosure, offering additional protection from environmental conditions. The Love Controls Analog Thermostat is designed for use in com-
tive, 50 VA inductive, 125 VA pilot duty at 120/240 VAC.
mercial cooking equipment, packaging machinery, sterilizers, test
Accuracy: Better than 1% of span at 25°C (77°F) and at rated
chambers and photographic processing systems. Ideal for replacement
line voltage.
of bulb-type thermostats, features include temperature ranges from 0
Stability: Typically less than 1°C/10°C (0.56°F/5.67°F) ambient
to 1000°F, ON/OFF temperature control with integral set point adjust-
change; ± 0.01% of span/ 1% change in line voltage.
ment, field or factory selectable (120/240 VAC) input power and choice
Set Point Adjustment: Local set point adjustment.
of thermocouple or Platinum RTD sensor inputs.
Cold Junction Compensation: Automatic with thermocouple
FEATURES
units.
• Surface or panel mount
• Fail-safe: shuts down on sensor failure
• Accepts platinum RTD or thermocouple sensor
Control Mode: On/off differential: 1°C (2°F) typical, reverse acting.
Ambient Operating Temperature: 0 to 55°C (32 to 130°F) standard. 0 - 90% R.H., non-condensing.
MODELS
Model
Number
60-1L1T
60-1L2J
60-1L3J
60-1L4J
60-1L4K
60-1L2P
Weight: (2.5 kg) 0.5 lb.
Sensor Type
T
J
J
J
K
1001 DIN RTD*
Range
-50 to 250°F
0 to 250°F
0 to 500°F
0 to 1000°F
0 to 1000°F
0 to 250°F
Terminals: 6.4 mm (0.25”) quick connects.
Sensor Protection:
RTD: Open or shorted sensor de-energizes load.
Thermocouple: Open sensor de-energizes load.
*0.00385 DIN Standard
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
281
Series
PP45
Temperature/Process Indicator
Temperature
Universal lnput, 0.1% Accuracy, 6 Digit Display
SPECIFICATIONS
The Love PP45 Series Temperature/Process Indicators offer a high level of standard features in an economical 1/8 DIN package. Featuring universal input for thermocouples, RTDs, differential input, and process input; the PP45 Series offers easy setup for most
temperature and process applications. A standard 24 Volt isolated, regulated power supply
is included to power most standard 4 to 20 mA transmitters.
Standard features include peak and valley indication and one button tare setting. For
process inputs the display is fully programmable from -32000 to +32000 with user placeable
decimal point. Most thermocouple and RTD inputs can show whole or tenth degree display.
The PP45 Series is available with dual alarm SPDT outputs rated at a full 10 Amps, and can
be programmed for high, low, or guardband (high/low) operation. All outputs are isolated
from the input. Other options include Analog Retransmission of the Process Variable and
Digital Serial Communication for either RS-232 or RS-485.
The PP45 sets a new standard in quality, features, ease of use, and value. While having a
high level of features and functions, program items only appear in the control menu when
the function is selected.
For the best value in a high accuracy 1/8 DIN panel meter, the choice is the Love Controls
PP45 Series.
Inputs:
• Thermocouple = 3 megohms minimum.
• Voltage = 5000 ohms.
• Current = 10 ohms.
• RTD current = 200 µA maximum.
Display: 6 digit, 7 segment 0.5˝ (12.7 mm) high. Resolution: 1° or 0.1°, or 1
count.
Accuracy: ±0.1% of span ±1 least significant digit.
Supply Voltage: 100 to 240 VAC nominal, +10% -15%, 50 to 400 Hz single
phase; 132 to 240 VDC +10% -20%.
Power Consumption: 5 VA maximum.
Operating Temperature: 14 to 131°F (-10 to 55°C).
Memory Backup: Non-volatile memory. Has no batteries.
Alarm Output Relay Ratings: SPDT, 10 A at 240 VAC resistive, 1/2 hp @ 120
VAC, 1/3 hp @ 240 VAC.
Alarm On-Off Differential: 1° F, C, or 1 count.
Isolation: Alarm Relay outputs, 1500 VAC from all inputs and outputs.
Loop Power Supply: Isolated 24 VDC @ 50 mA, regulated.
Weight: 13 oz (369 g).
Front Panel Rating: IP66 (Type 4X).
Agency Approvals: CE, UL.
INPUT RANGES
INPUT TYPE
Type J or L Thermocouple
Type K Thermocouple
Type T Thermocouple
Type E Thermocouple
Type R Thermocouple
Type S Thermocouple
Type B Thermocouple
Type C Thermocouple
Type N Thermocouple
100 1 Plt. 0.00385 DIN RTD
100 1 Plt. 0.00392 NIST RTD
120 1 Nickel 0.00628 US RTD
1000 1 Plt. 0.00385 DIN RTD
Current/Voltage/ 6 Voltage
1
RANGE °F
RANGE °C
-100 to +1607
-73 to +871
-200 to +2500
-129 to +1371
-350 to +750
-212 to +398
-100 to +1800
-73 to +982
0 to 3200
-17 to +1760
0 to 3200
-17 to +1760
+75 to +3308
+24 to +1820
0 to 4208
-17 to +2320
-100 to +2372
-73 to +1300
-328 to 1607
-200 to +875
-328 to 1607
-200 to +875
-112 to +608
-80 to +320
-328 to +1607
-200 to +875
Scalable Units from -1999 to +9999
MODELS
Part Number
Features
PP450
Indicator without Alarms
PP451
Indicator with Alarms
PP451-932
Indicator w/ Alarms and 0 (4) to 20 mA Retransmission
1
The 0 to 20 mADC, 4 to 20 mADC, 0 to 10 VDC, 2 to 10 VDC, and -10 to +10 mVDC inputs are fully
scalable from a minimum of 100 counts span placed anywhere within the range of -32000 to +32000. Decimal
point position is adjustable from the zero place (32000), tenths (3200.0), hundredths (320.00), thousandths
(32.000), or ten thousandths (3.2000).
NEMA 4 (IP-65) Mounting Enclosure for 1/8 DIN controls
and panel meters.
Accessory mounting bracket for 1/8 DIN controls and
panel meters.
The 1007-ENCL8, IP-65 (NEMA 4)
Mounting Enclosure for 1/8 DIN controls and panel meters, allows easy use in
a compact semi-portable format. The
enclosure has a standard 1/8 DIN cut-out
and will accommodate a PP45, LCI108,
LCI108J, LCI208, LCI308, LCI408, 8500
Series, 8600 Series, LCU108, or LCU208
indicators and controls.
The 1007-BRKT8 Accessory
Mounting Bracket Kit for 1/8 DIN
controls and panel meters allows easy
mounting of an accessory directly to
the rear of the PP45, D8500, or D8600
Series instruments. The kit includes
the bracket, terminal insulator barrier,
and screws.
The 1007-BRKT8 is designed to hold a
Series 668 pressure transmitter, but
may also be used for other transmitters
or solid state relays.
Four rubber feet allow for secure positioning on most flat surfaces. The top easily
removes with four screws to allow full
access to the interior for wiring and installation.
1007-ENCL8 shown with PP45
mounted.
1007-BRKT8 shown mounted on
PP45 with Dwyer Series 668
pressure transmitter (wiring omitted).
1007-BRKT8, Mounting Bracket Kit
Note: When mounting a solid state relay, make sure that the load is small enough so that additional heat sinking is not
necessary. Do not use a solid state relay on this bracket if the weight is more than 4 oz (125 g) or if the heat generated by the solid state relay will raise the ambient temperature of the bracket by more than 9°F (5°C).
1007-ENCL8, Mounting Enclosure
282
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
1300
Smart
Indicator/Transmitter
1/8 DIN, SQRT Function,
Universal Inputs, Alarms/Analog Retransmission Outputs
Front panel sealed to IP65, NEMA 4
Dwyer Series 1300 Smart Indicators/Transmitters are extremely versatile digital process controls, ideal for use with Dwyer
pressure, temperature and flow sensors. Microprocessor based, all
models are fully programmable and accept common thermocouple,
RTD, current or voltage inputs. An integral 20VDC power supply suitable for powering all Dwyer 2-wire transmitters is standard. Bright LED
display automatically indicates temperature range in °F (°C) based on selected thermocouple or RTD input. For flow monitoring or control with
Dwyer differential pressure transmitters, a preprogrammed SQRT
function may be selected to display actual engineering units in CFM,
GPM, etc. In addition, a user defined linearization table is provided
for non-linear functions, i.e., liquid level indication in a side mounted
cylindrical tank. Four independent alarm status LED displays are
fully programmable to indicate process condition at a glance.
The Series 1300 is available with a variety of output options including multiple alarm relays, analog retransmission (current),
bridge excitation (voltage) and serial communications. Alarms are
fully programmable: Hi, low, deviation, deadband, time delay, manual or automatic reset and NO or NC operation. Current retransmission may be any part of the indicated range and the high value of the
retransmission range may be lower than the low value (inversion).
Consult factory for specifications and availability of optional outputs
not listed.
Suggested Specification
Indicator/Transmitter shall be 1/8 DIN with front panel sealed to
IP65, NEMA 4. Process indication shall be 5 digit LED display with 4
independent LED alarm status displays. Programmable inputs shall
include thermocouples, RTD’s, current or voltage. Outputs shall be
(____). Indicator/Transmitter shall be Dwyer Model 13____.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Selectable Inputs: Thermocouple (J type stocked), field selectable K, T,
R, S, E, F, N, or B type; RTD (100 1 DIN); Current or Voltage.
Input Impedance: Thermocouple (1 M1 min.); RTD Current (1 mA max.);
Current (51 1) and Voltage (1 M1).
Dual Relay Output: DPST with shared common. Fully programmable for
High, Low or Deviation Alarm, deadband, time delay, manual or automatic
reset, NO or NC operation (factory wired NC in power-off state). Contacts
rated 8A max., 100 mA min., @ 240 VAC (< 100 mA switching current
may require removal of factory wired varistors across relay contacts) and
8A max. @ 30 VDC.
Current Retransmission Output: Spannable 4-20 mA, 0-20 mA or 0-10
mA; 0 mA min. 22 mA max.; Loop resistance: 0-700 1 (integral loop
powered), 0-1000 1 (externally powered 10-30 VDC).
Integral Power Supply (for 4-20mA, 2-wire transmitter input):
20VDC, 50 1 input impedance.
Power Requirements: 120 VAC, 50/60 Hz (as stocked); field configurable 240 VAC 50/60 Hz.
Accuracy (@ 20°C): Thermocouple input ±1°C Cold Junction Error ±1°C
(J, K, T type), ±2°C (R, S, E, F, N type) or ±3°C (B type); RTD input ±0.1%
of reading ±0.1°C; Current input ±0.1% full span; Voltage input ±0.02%
full span (0.1, 1, 10 volts), ±0.04% full span (1-5 volts).
Displays: 5 digit, 7 segment 14 mm (0.5˝) high LED display; Four independent alarm status LED indicators; 3.3 Hz update rate.
Display Resolution: User-adjustable.
Memory Backup: Nonvolatile memory.
Serial Communications: Optional RS485.
Operating Temperature: 10 to 40°C (Linearized and cold junction compensated).
Electrical Connections: Removable terminal blocks for ease of wiring.
Isolation: Power Supply to 1.5kV; Inputs to 500V; Relay Outputs to 500V;
Current Retransmission Output to 500V (typical).
Weight: 1 Ib, 14 oz (850 g).
Options: 24VAC 50/60 Hz Supply Voltage; SPDT Relay Output;
Programmable 2-20VDC or Constant 24VDC Outputs; RS485 Serial
Communications.
Agency Approvals: CE.
MODELS
Model No.
Output 1
Output 2
Comm.
13000
13020
13030
13220
13230
13024
None
DPST Relay
Retransmission
DPST Relay
DPST Relay
DPST Relay
None
None
None
DPST Relay
Retransmission
None
None
None
None
None
None
RS485
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
283
Temperature
PANEL CUTOUT FOR ALL MODELS 92X44 mm (3.622" X 1.732").
MAXIMUM PANEL THICKNESS WITH SEALING GASKET INSTALLED
3.5 mm (.1378"); WITHOUT 4.5 mm (.1772").
Series
SI
Smart Indicator
Temperature or Process, Interchangeable Output Modules
2.688
[68.28]
1.750
[44.45]
INTERCHANGABLE
MODULE
.750
[19.05]
Temperature
3.780
[96.01]
Series SI Smart Indicator is fully programmable and accepts
all commonly used temperature or process inputs. Programming
is via the front panel keys following a logical menu structure which
can be set to “short” (default) for common usage features or “full”
where the full range of programmable features are available. The
indicator can also be programmed via a PC using the RS485
Modbus® communication module. Password protection can be
enabled to prevent any unauthorized setting changes.
The Series SI features a 4-digit red LED with selectable resolution. The display can be set to indicate a fixed number of decimal
places or auto scale for maximum resolution. Optional interchangeable modules for relay, 4 to 20 mA retransmission, or
Modbus® RS485 serial communication output are easily installed
without the need for dismantling or recalibration.
Model SI-13 Smart Indicator is designed to accept 2 or 3-wire
Pt100Ω RTD or Types J, K, T, R, S, E, F, N, or custom thermocouple inputs. Temperature measurements can be displayed in
selectable °F or °C. High/low scale burnout, input filtering or
smoothing, and offset can be defined by the user.
Select Model SI-23 Smart Indicator for process signal input. The
indicator has an internal power supply to provide excitation to
field transmitters. Parameters such as input type, range, engineering units, resolution, burnout condition, and filter time constant can be easily programmed.
GENERAL
Input/Output Isolation: 500VAC
RMS (galvanically isolated).
Display Range: -999 to 9999.
Output Impedance: 7001 @
24 VDC.
Power Supply: 90 to 253VAC
50/60 Hz.
Ambient Operating Temp.:
-22 to 140°F (-30 to 60°C).
Filtering: Off, 2 seconds, 10 seconds, or adaptive.
Time Constant (Filter Off): <1
second (to 63% of final value).
Update Time: 250 msec
maximum.
Weight: 2 lb (0.9kg)
MODEL SI-13
Thermocouple Input Range:
J: -328 to 2192°F (-200 to
1200°C); K: -328 to 2498°F
(-200 to 1370°C); T: -328 to 752°F
(-200 to 400°C); R and S: -14 to
3200°F (-10 to 1760°C); E: -328 to
1832°F (-200 to 1000°C); F: -148
to 1112°F
(-100 to 600°C); N: -292 to
2372°F (-180 to 1300°C);
custom: ±9999.
RTD Input Range: Pt1001 2 or
3-wire: -328 to 1562°F
(-200 to 850°C).
Accuracy: T/C: ±0.04% full range
input, ±0.04% rdg; RTD; ±0.01 full
range input, ±0.05%
of rdg.
Thermal Drift: Zero: 0.05µV/°F
(0.1µV/°C), (RTD zero drift is
0.008°F/°F); Span: 50ppm/°F
(100ppm/°C).
Cold Junction Range: -40 to
185°F.(-40 to 85°C).
Cold Junction Error: ±1°F.
Cold Junction Tracking:
0.05°F/°F (0.05°C/°C).
Excitation Current: 300µA to
550µA.
Maximum Lead Resistance: 50
ohms/leg.
Lead Resistance Effect:
0.004°F/ohm (0.002°C/ohm).
Interchangeable Output Modules can quickly be connected to
the Smart Indicator and are automatically recognized. Dual relay
output module has two changeover relays with a common wiper.
Each relay can be set as high or low alarm independently. An isolated retransmission module provides 0 to 10 mA, 0 to 20 mA, or
4 to 20 mA output in active (source) or passive (sink) modes. The
output can be any portion of the display. The Modbus® serial communication module allows communication with a PC for configuring or monitoring.
MODELS
Module Type
SI-02P
SI-04P
SI-05P
Dual Relay Output (2 per unit max.)
4 to 20mA Retransmission (1 per unit max.)
Modbus® Communication (1 per unit max.)
284
VISIT OUR WEBSITES:
www.dwyer-inst.com
5.500
[139.7]
SPECIFICATIONS
Model SI-13 Smart Indicator for Temperature
Model SI-23 Smart Indicator for Process
Model No.
.430
[10.922]
MODEL SI-23
Voltage Input Range: 0 to 1V,
1 to 5V, 0 to10V.
Current Input Range: 0 to 20
mA, 4 to 20 mA, 0 to 10 mA.
Accuracy: ±0.05% full scale.
Thermal Drift: Zero: 0.05µV/°F
( 0.1µV/°C); Span: 50ppm/°F
(100ppm/°C).
Excitation: 24V ±5% @ 50 mA.
DUAL RELAY MODULE
Contacts: Two changeover relays,
common wiper.
Electrical Rating: AC: 253V; DC:
125V.
Maximum Load: AC: 7A@250V;
DC: 7A@30V.
Maximum Power: AC: 1750VA;
DC: 210W.
Connections: 5-way tension
clamp connector.
4 TO 20mA RETRANSMISSION
MODULE
Ranges: 0 to 10 mA, 0 to 20 mA,
4 to 20 mA (active or passive).
Isolation: 500VAC.
Accuracy: 0.07% full scale.
Maximum Output Load: Active:
1 K ohm; Passive: [(Vsupply-2)/20]
K ohm.
Max. External Supply: 30V (passive).
Connections: 5-way tension
clamp connector.
RS485 MODBUS®
COMMUNICATION MODULE
Isolation: 500VAC.
Physical Layer: 4-wire or 2-wire
half duplex RS485.
Baud Rate: 19,200 or 9,600.
Protocol: Modbus® RTU format.
Maximum Fan Out: 32 Units.
Connections: 5-way tension
clamp connector.
Modbus® is a registered trademark of Schnieder Automation.
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
LCI132
Process Indicator
1/32 DIN, Fully Programmable
43.5
(1.713)
70.0
(2.756)
21.0
(0.827)
48.0
(1.890)
11
(0.433)
24.0
(0.945)
6.35 (0.25)
Maximum Panel Thickness
The LCI132 has a 7.62mm (0.3 inch) high display. The shallow depth of
these full size panel meters allows installation in panels only 70mm
(2.76 inches) deep with room to spare.
Inputs are available for Process (0 to 10V, 4 to 20 mA), AC Volts, AC
Amps, DC Volts, and DC Amps.
FEATURES
•
•
•
•
MODELS
LCI132-10
LCI132-11
Input
± 100 VDC; ±20 VDC
±10 VDC; ±200 VDC; ±20 mA DC
±100 VAC; 600 VAC; 5A (DC) 1A (AC)
-199.9 to +600 VDC;
±100 VDC -1.999 to 5A (DC)
± 1A (DC)
Supply
Voltage
120/240 VAC
24/48 VAC
120/240 VAC
24/48 VAC
Process Display
Program Keys
CALL TO ORDER:
LCI132-0x
INPUT
Range:
Resolution:
VOLTS (DC)
±200V ±20V ±10V
0.1V 0.01V 1mV
U.S. Phone 219 879-8000
•
AMPERES
±100mV ±20mA
0.1mV 0.01mA
INPUT IMPEDANCE
Volts 1 Mohms.
mV: 100 Mohms.
mA: 12.1 ohms.
LCI132-1x
INPUT
Range AC:
Range DC:
Resolution
Large display
Easy to Program
Inputs for most processes
IP65 (NEMA 4X) Front
Model
Number
LCI132-00
LCI132-01
SPECIFICATIONS
VOLTS
600.0 100.0
-199.9 +600.0 ±100.0
0.1V
AMPERES
5.000 1.000
-1.999 +5.000±1.000
1mA
INPUT IMPEDANCE
Volts: 3 Mohms (106).
Amp: 12 mohms (10-3).
ALL ACCURACY at 23ºC ±5ºC
100/600 Vdc 1/5 Adc; 600V/5A ac: ±(0.2% reading + 3 digits)
100V / 1A ac: ±(0.4% reading + 4 digits)
Temperature Coefficient: 100 ppm/ºC
Warm Up: 5 minutes
POWER SUPPLY AND FUSES (DIN 41661) (Not supplied):
LCI132-x0:
85–265 Vac 50/60 Hz and 100-300Vdc: Fuse: 0.1A/ 250V
LCI132-x1:
21-53 Vac 50/60Hz and 10.5-70Vdc: Fuse 0.5A/ 250V
Power Consumption: 1.8W Max.
DISPLAY
Range: -1999 to 9999 (dc) 0 to 9999(ac)
Type: 4 red digits 10mm
Reading Rate: 4/s
Overflow Indication: OVR
ENVIRONMENTAL
Operating Temperature: -10ºC to +60ºC
Storage Temperature: -25ºC to +85ºC
Relative Humidity (non condensed): <95% @ 40ºC
Panel Sealing: IP65
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
285
Temperature
The LCI132 Series process indicators offer flexibility, and value
in a low cost, compact 1/32 DIN package. This family of indicators
offers input availability for most types of process measurement.
Series
LCI208
4 Digit Panel Meter Indicator
High Accuracy, Peak and Valley Display, Tare Feature
SPECIFICATIONS
The LCI208 Series 4 digit panel meter indicators offer flexibility, and value
in a low cost, compact 1/8 DIN package. This family of indicators offers input availability for virtually all types of process measurement.
Inputs: Process, temperature (T/C & RTD).
Input Impedance:
Process: Voltage, 1 M1; Current, 12.11.
Current, 0.012 1 for 5A, 0.061 for 1A.
Display: 4 Red, 14 mm digits, programmable decimal point, 4 LEDs for control
and 4 for output status.
Accuracy: ±0.1% of reading (except temperature); ±0.4% of reading for thermocouple; ±0.1% of reading for RTDs.
Supply Voltage: 120/240 VAC, 50/60 Hz ±10%.
Power Consumption: 3W max.
Operating Temperature: 14 to 140°F (-10 to 60°C) / <95% @ 40°C (104°F) noncondensing.
Front Panel Rating: IP65 (Type 4X).
Agency Approvals: CE.
Temperature
Inputs are available for Process (0 to 10V, 4 to 20 mA), Electrical Variables) AC
Volts, AC Amps, DC Volts, DC Amps), Temperature (RTD & Thermocouple), and
Frequency. The process load cell, and frequency inputs have appropriate transducer excitation power supplies. Peak and Valley indication and a Tare function are
standard. Options include set point outputs (2 SPDT 8A mechanical relays), RS232/RS-485 computer communications, and 4 to 20 mA analog retransmission.
MODELS
Model No.
Input
LCI208-00
LCI208-10
LCI208-30
Process
Thermocouple (J, K, T)
RTD
Series
LCI108
&
LCI108J
4 Digit Panel Meter Indicator
3-1/2 Digit Display, Self-Tune/Fuzzy Logic
The LCI108 & LCI108J Series 3-1/2 digit panel meter indicators offer flexibility, and value in a low cost, compact 1/8 DIN package. This family of indicators
offers input availability for virtually all types of process measurement. The LCI108
& LCI108J are identical except for the size of the display. The LCI108 has a 0.56
inch (14 mm) high display. The LCI108J (jumbo) has a 0.80 inch (20 mm) display for
viewing from longer distances. Inputs are available for Process (0 to 10V, 4 to 20
mA), AC Volts, AC Amps, DC Volts, DC Amps, Temperature (RTD), Temperature
(Thermocouple), and Frequency. The process and frequency inputs have appropriate transducer excitation power supplies, giving you everything you need in a compact package.
SPECIFICATIONS
Inputs: Process, Thermocouple, RTD, VAC, VDC, A AC, A DC,
Frequency.
Input Impedance:
Process: Voltage, 1 M1; Current, 12.11.
AC & DC Current: 0.0121 for 5 A, 0.061 for 1 A.
AC & DC Voltage: 3 M1 for 600 V, 300 k1 for 200 V, 30 k1 for 20 V.
Display: 4 digit, 14 mm Red for LCI108; 4 digit, 20 mm Red for
LCI108J; Programmable decimal point with 2 LEDs for output status indication on all units.
Accuracy: ±0.1% of reading (except T/C & RTD); ±0.4% of reading for
T/C; ±0.1% for RTD.
Supply Voltage: 120/240 VAC, 50/60 Hz ±10%.
Power Consumption: 3 W max.
Operating Temperature: 14 to 140°F (-10 to 60°C) / <95% @ 104°F
(40°C) non-condensing.
Front Panel Rating: IP65 (Type 4X).
Agency Approvals: CE.
MODELS
286
Model No.
Input
LCI108-00
LCI108-10
LCI108-20
LCI108J-10
LCI108J-20
Process
T/C (J, K, T)
RTD
T/C (J, K, T)
RTD
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
LCI308
&
LCI408
Panel Meter Indicators
1/8 DIN, High Accuracy, Peak & Valley Display
16
( 0.63)
96
( 3.78)
120
( 4.72)
7
(0.28)
2
RUN
TARE
HOLD
LIMIT
MAX
MIN
DATA
3
PRG
INP1
DSP1
INP2
DSP2
FLT
STORE
4
TEACH
ESC
LIMIT
MAXIMUM
DATA
ENTER
91
(3 . 5 8 3 )
RESET
96
(3 . 7 8 )
TARE
MODELS
Part Number
Description
LCI308-00
LCI408-00
1/8 DIN Indicator, Process Inputs
1/8 DIN Indicator, Universal Input
Consult Factory for add-in option cards.
SPECIFICATIONS
Inputs: Process, temperature (T/C & RTO).
frequency/counter, load cell (dependent on model number).
Input Impedance:
Process: Voltage, 1 M1; current, 12.11.
Load Cell: 100 M1 for 300 mV, 1 MW for 30 mV.
Display: 5 digit, 7 segment, 14 mm red with a fixed decimal point. 14 LEDs (programming & control).
Accuracy:
LCI308: ±0.1% of reading (except temperature inputs).
Thermocouples: ±0.4% of reading for types J, K, T, & E /
±.05% of reading for types R & S.
RTD: ±0.2% of reading.
LCI408: ±0.1% of reading.
Supply Voltage: 115/230 VAC 50/60 Hz ±10%.
Power Consumption: 3W max.
Weight: 8 oz (250 g).
Front Panel Rating: IP65 (Type 4X).
Agency Approvals: CE.
INPUT RANGES
INPUT TYPE
RANGE °F
RANGE °C
Type J Thermocouple
-58.0 to +1472.0
-50.0 to +800.0
Type K Thermocouple
-58.0 to +2282.0
-50.0 to +1250.0
Type T Thermocouple
-328.0 to +752.0
-200.0 to +400.0
Type RT Thermocouple
+32.0 to +3182.0
0.0 to 1750.0
-Type S Thermocouple
-58.0 to +3182.0
-50.0 to +1750.0
Type E Thermocouple
-58.0 to +1832.0
-50 to +1000.0
100 Ohm Plt. 0.00385 DIN RTD
-328 to 1472.0
-200.0 to +800.0
100 Ohm Plt. 0.00392 NIST RTD
-328 to 1607
-200 to +875
Process (Includes excitation power supply)
±10V
Scalable Units from -32000 to +32000 (LCI308);
-99999 to +99999 (LCI408)
±20mV
Scalable Units from -1999 to +1999
Digital - Frequency/Counter (Includes excitation power supply)
0.1 to 25,000 Hz
Count up/down 10,000 Hz (LCI308)
Potentiometer
Resolution to 0.001% (LCI408)
Load Cell (includes excitation power supply)
±30mVDC
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
287
Temperature
The Series LCI308 and LCI408 panel meter indicators offer
flexibility and value in a standard 1/8 DIN package. This family of
indicators offers input availability for virtually all types of process
measurement.
The LCI308 offers a 4-3/4 digit display scalable to ±32,000 counts.
This flexible indicator is available for Process Inputs (0-10VDC, 4-20
mA, etc.), Temperature Inputs (Thermocouple Types J,K,T, and DIN
RTD), Timer/Counter type, and Load Cell (strain gauge) Inputs.
The LCI408 has a universal input that accepts the Process,
Temperature, and Load Cell inputs of the LCI308, plus a
Potentiometer input. The full 5-digit display can be scaled between
±99999 counts. The dual display allows simultaneous display of the
measured value plus other values such as peak or valley.
Options include relay and transistor set point outputs, BCD Parallel
output, RS-232/RS-485 computer communications, and 4 to 20 mA
analog retransmission.
44
(1 . 7 3 )
1
B
48
(1 . 8 9 )
PROG
A
Digital Panel Meters
1/8 DIN, Process, Load Cell & Potentiometer Input
16
( 0 .6 3 )
96
( 3 .7 8 )
8
A
B
RUN
TARE
PRG
INP1
88888
2
LIMIT
MAX
MIN
DATA
3
DSP1
INP2
DSP2
FLT
STORE
4
TEACH
ESC
LIMIT
MAXIMUM
DATA
ENTER
Temperature
The Series LCI508/608 Digital Panel Meters offer high performance and a multitude of features for displaying and manipulating
input variables. The unit accepts analog process input, load cell and
potentiometer inputs. Standard features include data hold, peak and
valley display, store function, tare function and reset. Both models
offer a built-in excitation power supply. The Series LCI508/608 can be
fitted with optional output modules for control capabilities.
91
( 3. 583)
96
( 3. 78)
RESET
SPECIFICATIONS
Input: Voltage Process: ±5 and ±10)V (Input Impedance: 1M1);
Voltage: ± 0-1V (Input Impedance: 100M1);
Current Input: ±0-20 mA (Input Impedance: 11.81).
Load-Cell:
Voltage Input: ±30, ±60, ±120, ±300, ±500 mV (Input Impedance:
100M1); 4-wires, unipolar or bipolar.
Potentiometer Input:
Minimum Resistance: 1201 (Input Impedance: >10 M1).
Excitation Voltage: 2.2V.
Excitation:
2.2 V @ 30 mA not adjustable.
24 V @ 30 mA not regulated.
5 V ±100 mV @ 120 mA with fine adjust (50ppm/ºC).
10 V ±10 mV @ 120 mA with fine adjust (50ppm/ºC).
Display Range:
Main Display: -9999/9999, 5 red digits, 7 Segments.
Aux. Display: -9999999 / 9999999, 8 green digits 8 mm (LCI608
only). Decimal Point: Programmable (both displays).
Sampling Rate: LCI508: 555/s; LCI608: 200/s.
Accuracy:
Error max: ±0.1% reading +2 digits.
Temperature coeffi cient: 50 ppm/ºC.
Warm up time: 10 minutes.
Power Requirements: 115/230VAC 50/60Hz.
Consumption (without options): 5W.
Ambient Operating Temperature: 14 to 140°F (-10 to 60°C).
Storage Temperature Range: -13 to 185°F (-25 to 85°C).
Panel Cutout: 3.6 x 1.8˝ (92 x 45 mm).
Weight: 21 oz (600 g).
Case Material: s/UL 94 V-0 Polycarbonate.
Front Panel Orientation: IP65.
The Model LCI508 is designed with 31 programmable functions and a
high conversion rate of 555 reads per second. Up 30 points can be set
using the multipoint scaling function for non linear applications.
The Model LCI608 is designed for measuring and integrating analog
signals containing two sets of information simultaneously (for example
Flow and Totalization). The units can be configured to accept and display two analog input signals and allowing interaction between them.
The model LCI608 offers 26 logical programmable functions
LCI508-00, Panel Meter
LCI608-00, Panel Meter/Totalizer
Accessories
LCIA-01, Dual Relay Card. Two SPDT relays, 8A @ 240VAC
LCIA-02, Quad Relay Card. Four SPST relays,
0.2A @ 240 VAC
LCIA-03, Quad Transistor Output Card. Four NPN optically
coupled transistors, 50 mA @ 50 VDC max.
LCIA-04, Quad Transistor Output Card. Four PNP optically coupled
transistors, 50 mA @ 50 VDC max.
LCIA-05, Analog Retransmission, 4 to 20 mADC
or 0 to 10 VDC, selectable.
LCIA-07, BCD Output Card.
LCIA-08, RS-232 Serial Communication (Modbus®)
LCIA-09, RS-485 Serial Communication (Modbus®)
Modbus® is a registered trademark of Schnieder Automation.
288
VISIT OUR WEBSITES:
www.dwyer-inst.com
7
( 0. 28)
1
HOLD
TARE
120
( 4 .7 2 )
48
( 1. 89)
PROG
44
( 1. 73)
Series
LCI508
&
LCI608
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Accessories for LCI Series
LCIA-01 Dual Relay Output Option Card for LCI108, LCI108J, LCI208,
LCI308, and LCI408 1/8 DIN panel meters
LCIA-07 BCD Output Option Card for LCI308 and LCI408 1/8 DIN panel
meters.
SPECIFICATIONS
Relay Output: 2 SPDT relays rated at 8 A @250VAC
resistive.
Maximum Power: 2000VA, 192W.
Maximum Voltage: 250 VAC, 150 VDC.
Contact Resistance: 3m1 maximum.
Output Response Time: 10 ms maximum.
*Note: Not for use on LCI108 or LCI108J input types
3, 4, 5, or 6.
LCIA-02 Quad Relay Output Option Card
for LCI208, LCI308, and LCI408 1/8 DIN panel meters
SPECIFICATIONS
Output: 5-1/2 digits Tri-state logic for 5V TTL or 24VDC
signals.
Data Transfer Time: 2 ms.
LCIA-08 RS-232 Serial Communications Option Card for LCI308 and
LCI408 1/8 DIN panel meters.
SPECIFICATIONS
Output: RS-232-C, full duplex, 4 wire, via RJ-11 connector.
Protocol: Selectable ISO1745 (ASCII) or Modbus® RTU.
Baud Rates: 1200 or 19200 baud, selectable.
Address Range: 0 to 99.
SPECIFICATIONS
Relay Output: 4 SPDT relays rated at 0.2 A @250VAC
resistive.
Maximum Power: 25VA, 192W
Maximum Voltage: 250 VAC, 10 VDC
Contact Resistance: 200m1 maximum
Output Response Time: 6 ms maximum
LCIA-09 RS-485 Serial Communications Option Card
for LCI308 and LCI408 1/8 DIN panel meters.
LCIA-05 Isolated Analog Retransmission
for LCI308, and LCI408 1/8 DIN panel meters
LCIA-06 Isolated Analog Retransmission Option Card for LCI208 1/8
DIN panel meters.(Not available for input codes 5 or 7)
SPECIFICATIONS
Output: 4 to 20 mADC into 500 ohms maximum.
Resolution: 12 bits.
Accuracy: 0.2% of full scale ±1 bit @ 23°C ±5°C (73°F
±9°F).
Response Time: 120 ms maximum.
Thermal Drift: 0.2µA/°C.
Isolation: Analog output to input signal, 3750V; Analog
output to power and optional relay(s), 2300V.
Model
PM706
LCIA-10 RS-232/RS-485 Serial Communications Option Card for
LCI208 1/8 DIN panel meters.
SPECIFICATIONS
Output: RS-485, half duplex, 3 wire, via RJ-11 connector; and RS-232-C, full duplex, 4 wire, via RJ-11 connector.
Protocol: Selectable ISO1745 (ASCII) or Modbus® RTU.
Baud Rates: 1200 or 19200 baud, selectable.
Address Range: 0 to 99.
Temperature
Panel
Meter
Dual Alarm, Relay and Analog Output
Model PM706 Digital Temperature Meter monitors and displays temperature measurements using a Type K thermocouple input. Meter features dual adjustable set points with lA relays and a selectable 4-20 mA or 0-10 VDC output
signal . View alarm settings by depressing the tactile alarm button on the front
panel. The bright red LED display has a floating decimal point and displays temperature in °F or °C. Meter is equipped with overrange indication to alert operator of an open thermocouple or faulty connections. Sealed front panel is rated
to NEMA 12 to protect against dust and fluids.
PM706 Digital Temperature Panel Meter
CALL TO ORDER:
SPECIFICATIONS
Output: RS-485, half duplex, 3 wire, via RJ-11 connector.
Protocol: Selectable ISO1745 (ASCII) or Modbus® RTU.
Baud Rates: 1200 or 19200 baud, selectable.
Address Range: 0 to 99.
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Temperature Range: -148 to
1999°F (-100 to 1200°C).
Input: Type K thermocouple.
Output: Dual alarm rated 1A @
250VAC, 4-20 mA with 8V max
compliance or 0-10 VDC 1 k1 min.
Power Requirements: 115/230
VAC, ±10%, 50/60 Hz.
Power Consumption: 7 W.
Accuracy: ±2% at 23°C ambient.
Display: 4-digit, red, 1/2˝ digits.
Resolution: 1°F/°C.
Operating Temperature: 32 to
122°F (0 to 50°C).
Ambient Temperature Effect:
+0.01% of rdg., -0.05° per degree.
Temperature Coefficient: ±100
U.K. Phone (+44) (0)1494-461707
•
Set Point Adjustment: 0 to 2000
counts, adj. within 5 counts or better. ppm/°C.
Read Rate: 2.5 readings/sec.
Weight: 1 Ib (500 g).
Front Panel Rating: 1/8 DIN,
NEMA 12.
Suggested Specifications
Temperature meter shall have dual
relay alarms and selectable 4-20 mA
or 0-10 VDC analog output.
Temperature shall be displayed in
°F/°C (selectable). The housing shall
be suitable for NEMA12 service.
Meter shall be Dwyer Model No.
PM706.
Asia Pacific Phone 61 2 4272-2055
289
Temperature
SPECIFICATIONS
Output: Selectable 0 to 10 VDC into 500 ohms minimum, 4 to 20 mADC into 800 ohms maximum.
Resolution: 12 bits.
Accuracy: 0.1% of full scale ±1 bit.
Response Time: 60 ms maximum.
Thermal Drift: 0.2 mV/°C; 0.5µA/°C.
Series
650
Temperature Transmitter
4-20 mA Signal, Two Wire Operation, Temperatures from -55 to 180°C
13/64
[5.16]
Ø1/8 [3.18]
45/64
[17.86]
1-53/64
[46.43]
1-5/16
[33.34]
19/32
[15.08]
5/16 [7.94]
13/64 [5.16]
3/16 [4.76]
7/32 [5.56]
Temperature
2-5/8 [66.68]
SPECIFICATIONS
The Dwyer Series 650 Temperature Transmitter combines low
cost with small size making it ideal for a wide variety of HVAC, industrial and commercial multi-point temperature monitoring applications.
Non-polarized terminals simplify connection to any 12-35 VDC power
supply. Capable of operation with long cable runs, Series 650 Transmitters are well suited for monitoring air or water temperatures at remote locations. Three models are stocked in popular ranges factory
calibrated within 0.3% of span. All are linear within 0.25% of span and
may be recalibrated within low range and span limits shown in chart.
Low Range is temperature corresponding to 4 mA output. Span is temperature difference between Low and High Ranges corresponding to 420 mA output signal.
Input: Silicone-junction transistor.
Output Signal: 4-20 mA DC.
Power Requirements: 12-35 volts DC.
Accuracy: ±0.3% F.S. @ 20°C (68°F).
Linearity: Within 0.25% of span
Thermal Drift: Less than 0.5% of span
over ambient temperature range of
0 to 50°C (32 to 122°F).
Probe Construction: 6˝ long, 0.25˝
O.D. Type 304 SS.
Ambient Operating Temperature:
0 to 70°C (32 to 158°F).
Temperature Limits: (Probe): 204°C
(400°F).
Probe Cable Length: 7 ft (2.1 m).
Voltage Stability: Output error less
than 0.01% of span over the specified
supply voltage range.
MODELS
All Series 650 models listed
A-325 Duct Mounting Kit with flange, fitting and hardware
Model
Number
Range
As Stocked
650-1
650-2
650-3
-23° to +10°C
-7° to +49°C
0° to +100°C
Low Range Limits
Min.
Max.
Span Limits
Min.
Max.
-32°C
-14°C
24°C
48°C
-12°C
+6°C
37°C
150°C
Consult factory for special ranges calibrated within the limits of -55°C and +180°C
Series
651
Temperature Transmitter
RTD or Thermocouple Input, Zero and Span Adjust, Linearized 4-20 mA Signal
Linearized output for precise temperature monitoring or control is combined with
small size and quick, easy mounting. Rugged Series 651 transmitters are designed for
use with 2 or 3 wire Pt100 RTDs (to DIN standard 43760 or BS1904) or ungrounded
Type K thermocouples. Thermocouple models 651TC are cold junction compensated,
automatic 32 to 160°F (0 to 70°C) with upscale burnout. These economical devices provide the accuracy and reliability you need at the lowest possible cost.
SPECIFICATIONS
Input: 2 or 3 -wire Pt100 RTD (models 651A), or ungrounded Type K thermocouple
(models 651TC).
Output: 4-20 mA DC, linearized. Transmitter Type: 2-wire.
Output Impedance: 7001@ 24VDC
Power Requirements: 10-32 VDC, reverse connection protected.
Accuracy: ±0.2°C plus 0.2% reading (models 651A), ±0.1% FS plus cold
junction errors (models 651TC).
Temperature Drift: ZERO drift typical 0.02%/°C (0.09°F), SPAN typical 0.005%/°C
(0.0036°F).
Ambient Operating Temperature: 32 to 122°F (0 to 50°C).
Maximum Storage Temperature: 160°F (70°C)
Response Time: 10-90% in 200 ms (models 651A), 70% in 2 ms (models 651TC).
Agency Approvals: CE.
MODELS
Model No.
Input Type
Range,°F (°C)
651A-10
651A-20
651A-40
651TC-01
651TC-02
651TC-04
651TC-06
Pt100 RTD
Pt100 RTD
Pt100 RTD
Type K Thermocouple
Type K Thermocouple
Type K Thermocouple
Type K Thermocouple
32-212 (0-100)
32-392 (0-200)
32-752 (0-400)
32-212 (0-100)
32-392 (0-200)
32-752 (0-400)
32-1112 (0-600)
290
VISIT OUR WEBSITES:
www.dwyer-inst.com
Accessory
A-709, Optional enclosure for Series 651Transmitters. NEMA 1 protective
housing is 3" x 21⁄8" (76 x 54 mm). Supplied with mounting hardware,
strain relief fitting and assembly instructions.
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
659
Push-Button Temperature Transmitter
Programmable, RTD, Thermistor or Thermocouple Input, In-Head Mounting
Ø3/16 [4.76]
MOUNTING HOLE
TYP 2 PLACES
Ø1-41/64 Ø1-5/16
[41.67] [33.32]
29/32
[23.02]
Series 659 Push-Button Temperature Transmitters accept thermocouple (J, K, T), RTD (Pt100Ω) or thermistor input and provide a linearized
4 to 20 mA output. The transmitter is quickly ranged and calibrated by using
a single on-board switch. An LED provides visual indication of sensor fault
and programming mode. Models feature reverse polarity protection.
Thermocouple models are also galvanically isolated and cold junction compensated.
MODELS
Model Number
659TC-1
659RTD-1
659TH-1
Input
Thermocouple (Type J, K, T)
(3-wire RTD Pt1001)
Thermistor (22521)
Model
652-0
Input Range: Type J T/C: -328 to 2192°F (-200 to 1200°C); Type K
T/C: -328 to 2498°F (-200 to 1370°C); Type T T/C: -328 to 752°F
(-200 to 400°C); Pt1001 RTD: -328 to 1562°F (-200 to 850°C);
Thermistor: -13 to 257°F.
Accuracy: T/C models: ±0.04% F.S., ±0.04% of reading or ±0.5°C
whichever is greater; RTD: ±0.2°C ±0.1% of rdg; Thermistor: ±0.25°F
(±0.1°C).
Output: Linearized 4 to 20 mA, 2-wire loop powered.
Sample Rate: 500 ms.
Loop Resistance: T/C: 7001 @ 24 VDC; RTD: 8001 @ 24VDC;
Thermistor: 24 VDC.
Output Thermal Drift: Zero: 0.2µA/°C; Span: 0.5µA/°C.
Ambient Operating Temperature: -4 to 158°F (-20 to 70°C), 80%
RH max.
Ambient Storage Temperature: -40 to 158°F (-40 to 70°C), 95%
RH max.
Burnout: Upscale 22 mA.
Weight: 0.92 oz (26 g).
Programmable Transmitter
RTD, Thermocouple, Voltage or Potentiometer Input, Galvanically Isolated
2.312
[58.72
3 FOOT
(1m) LEAD
3.00
[76.2]
3 FOOT (1m)
CONNECTING
CABLE
01.648
[41.859]
Model 652-0 Programmable Transmitter accepts any commonly
used temperature sensor, slidewire transducer or millivolt signal and
produces a 4 to 20 mA output signal. Input type and range are easily
programmed using a PC and the simple Windows™ based software
program model 652-C sold separately. The user can completely reconfigure units of measure, high/low range, filtering factor, offset, and
transmitter reference details. The model 652-0 features 500V input to
output isolation to remove ground loop effects and four filter settings
to remove incoming signal noise. Outstanding versatility and compact
size make this unit ideal for any temperature application.
Model 652-0 Programmable Transmitter
ACCESSORIES
Model 652-C Configuration Kit (includes power adapter, configuration module, software and carrying case).
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Input/Output Isolation:
500 VAC RMS.
Thermocouple Input Range: J:
-328 to 2192°F (-200 to 1200°C);
K: -328 to 2498°F(-200 to
1370°C); T: -328 to 752°F (-200 to
400°C); R and S: -14 to 3200°F
(-10 to 1760°C); E: -328 to 1832°F
(-200 to 1000°C); F: -148 to
1112°F (-100 to 600°C); N: -292 to
2372°F (-180 to 1300°C).
RTD Input Range: (Pt1001):
-328 to 1562°F (-200 to 850°C).
Output: Linearized 4 to 20 mA.
Output Impedance: 7001 @ 24
VDC.
Power Requirements: 10 to 35V.
Accuracy: T/C: ±0.04% full range
input, ±0.04% rdg.; RTD; ±0.01 full
range input, ±0.05% of rdg.;
Voltage: 10µV, ±0.07% rdg.;
U.K. Phone (+44) (0)1494-461707
•
Potentiometer: 0.1% full range
input.
Thermal Drift: Zero: 0.1µV/°C
(RTD zero drift is 0.008°F/°F);
Span: 100ppm/°C.
Ambient Operating Temp.:
-40 to 185°F (-40 to 85°C).
Response Time: <1 second.
Update Time: 250 msec max.
Filtering: Off, 2 seconds, 10 seconds, or adaptive.
Cold Junction Error: ±29°F
(±0.5°C).
Computer Interface: RS232 via
configurator 652-C, IBM compatible 386 or above with 4mB Ram
and serial port.
Housing: Noryl™.
Weight: 0.92 oz (26 g).
Max. Output Load: 7001 @ 24
VDC.
Agency Approvals: CE.
Asia Pacific Phone 61 2 4272-2055
291
Temperature
The compact transmitter can be mounted directly within any standard thermal head for connection to the sensor. The Series 659 Transmitters are ideal
for temperature measurement in boilers, burners, ducts, furnaces, refrigeration systems, food processing, tanks, chemical processing, steam generators or any other process application.
SPECIFICATIONS
Loop
Alarms
Accepts Inputs from Thermocouples, RTDs
™
Series
1290
1490
Model 1290 Input Type and Ranges
Loop Alarms™ Accept inputs from
thermocouples (1290), RTDs
(1490). SPDT relay outputs can be
set for latching or non-latching, direct or reverse action and high or
low function. Output behavior is
easily programmable via switches.
Mount in standard 11-pin sockets.
Dimensions: Including socket
pins, 23⁄8" W x 37⁄16" H x 13⁄4" D (60.3
W x 87.3 H x 44.4 D mm).
Temperature
SPECIFICATIONS
Isolation: 1500 Volts RMS between
input, outputs and power.
Power Supply: 85-265 VDC/VAC,
50-400 Hz.
Setpoints: Adjustable from 0-100%
of span.
Deadband: Adjustable from 0.25100% of span.
Drift: ±0.02% /°C typical, ±0.05%
/°C maximum.
Ambient Operating Temperature:
32-131°F (0-55°C) non-condensing.
Input Impedance: (1290) 3
megohms, Current input=10 ohms.
Model 1490 Input Type and Ranges
Search Current (1490): Cu 101 = 5
mA. Plt 1001, Ni1001, Ni1201 =500µA.
Plt 5001, NiFe 10001, NiFe 20001 =
100 µA. Plt 10001 = 50µA.
Relay Output: SPDT, one set per
setpoint, 5A @ 250 VAC resistive.
Latch Circuit Reset: Automatic at
power up. Manual with reset switch.
Lead Compensation Error (1490):
0.02%/1.
Indicators: One dual color LED per
setpoint; red = On, green = Off.
Open Thermocouple Protection
(1290): Selectable upscale or
downscale.
Series
SC1290
SC1490
Type J Thermocouple
-346 to +374°F (-210 to 190°C)
-346 to +680°F (-210 to 360°C)
32 to +374°F (0 to190°C)
32 to +680°F (0 to 360°C)
32 to +1400°F (0 to 760°C)
Type K Thermocouple
-454 to +482°F (-270 to +250°C)
-454 to +896°F (-270 to +480°C)
32 to 482°F (0 to 250°C)
32 to 896°F (0 to 480°C)
32 to 2501°F (0 to 1372°C)
Type R Thermocouple
32 to 1778°F (0 to 970°C)
32 to 3200°F (0 to 1760°C)
Type E Thermocouple
-454 to +302°F (-270 to +150°C)
-454 to +554°F (-270 to +290°C)
32 to +302°F (0 to +150°C)
32 to +554°F (0 to +290°C)
32 to +1220°F (0 to +660°C)
32 to +1832°F (0 to +1000°C)
Type S Thermocouple
32 to 1922°F (0 to +1050°C)
32 to 3200°F (0 to +1760°C)
Type T Thermocouple
-454 to +410°F (-270 to +210°C)
-454 to +734°F (-270 to +390°C)
32 to 410°F (0 to 210°C)
32 to 734°F (0 to 390°C)
Ni120 RTDs
-58 to +482°F (-50 to +250°C)
Cu10 RTDs
32 to 482°F (0 to 250°C)
NiFe 1000, 2000 RTDs
-58 to +392°F (-50 to +200°C)
Pt 100, 500,1000 RTDs
32 to 212°F (O to 100°C)
32 to 572°F (O to 300°C)
32 to 932°F (O to 500°C)
Ni100 RTDs
-58 to +302°F (-50 to +150°C)
Model 1490
Model 1290
No. 481-0164 Socket
Thermocouple & RTD Limit/Alarm Switch Module
Two Form C (SPDT) Switches, Small Size, Mounts Easily on 35 mm DIN Rail
7
8
0.886"
(22.5)
9
All dimensions in inches (millimeters)
DIN EN 50022-35
(not supplied)
10 11 12
MODE
MODE
1 2 3 4
1 2 3 4
VOLTAGE
CURRENT
UNIPOLAR
BIPOLAR
ZERO BASED
ZERO +20%
SW2
OUTPUT
ON
MODE
5 6 7 8
KEY
= ON
= OFF
BLANK =
NOT
APPLICABLE
DUAL
SINGLE
LO
HI
ALARM B DIR
REV
SW4
SW1
1 2 3 4 5 6 7 8
INPUT
ON
1 2 3 4
2.95"
(75)
1 2 3 4 5 6 7 8
DB
1 2 3 4 5 6 7 8
B
RESET
ON
AL
A
RANGE
10mV/1mA
50mV/5mA
100mV/10mA
200mV/20mA
0.5V/50mA
1V/100mA
5V
10V
3.88"
(98.5)
LO
HI
ALARM A DIR
REV
NON LATCHING
LATCHING
290-2887
1.40"
(35.3)
Adaptor
Bracket
For Surface
Mounting
(Optional)
KIT#: 100735DINADPTR
3.88"
(98.5)
SPECIFICATIONS
Power Supply: (SC units) 85 to 265
VDC/VAC 50 to 400 Hz (12-24 VDC,
VAC 50-400 Hz for Low Voltage
Option, SCL units).
Isolation: 1500 V rms between outputs, input, and power.
Set Points: Adjustable 0 to 100% of
span.
Deadband: Adjustable 0.25% to
100% of span.
Drift: ±0.02%/˚C typical ±0.05%/˚C
maximum.
Ambient Temperature Range:
(operating) 32 to 131˚F (0 to 55˚C).
(storage) -40 to +176˚F (-40 to
+80˚C).
Excitation Current: (SC1490)
Cu101 = 5mA; Plt 1001, Ni 1001,
Ni 1201 = 500µA; Plt 5001, NiFe
10001 = 100 µA; Plt 10001 =
50 µA.
The Series SC1290 & SC1490 Thermocouple Limit/Alarm Switch Modules
are on-off or limit switches with selectable, thermocouple, or RTD inputs. Input
type, scale range, output action, and output type are all selectable by the user in
the field. All selections are made through easily accessible switches without the
need to open the product.
Each unit has two form C (SPDT) relays which can operate independently, or be
logically connected to operate as a DPDT output. A two color LED indicator indicates the status of each output relay.
These units mount easily on a standard 35mm DIN rail. Low Voltage (SCL XXXX)
units are also available.
MODELS
Model Number
Description
SC1290
SC1490
SCL1290*
SCL1490*
T/C Input
RTD Input
T/C Input
RTD Input
Lead Compensation Error:
(SC1490) 5 0.02%/1.
Open Lead Protection:
(SC 1490) Upscale only.
Input Impedance: (1290) 3
megohms.
Sensor Burnout Protection:
Selectable, upscale or downscale on
1290.
Relay Output: Form C, SPDT, one
per set point, 5A @ 250 VAC, resistive.
Latch Circuit Reset: Automatic at
power up. Manual with reset switch
on front of module.
Indicators: one dual color LED per
set point. Red = relay on, green =
relay off.
Wiring Terminals: Screw driven
compression type.
Dimensions: 2.95˝ H x 0.89˝ W x
3.89˝ D (75 x 22.5 x 98.5 mm).
* Low Voltage Supply
292
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
SC4130
SC4151
SC4380
Iso-Verter® II Signal Conditioning Modules
Accepts Virtually All Standard Process Signals
ADAPTER BRACKET FOR SURFACE
MOUNTING CAT #1007-35DINADPTR
0.886
[22.5]
1.400
[35.5]
2.950
[75]
3.880 [98.5]
*Note: The term “bipolar” refers to an input or output that crosses zero volts. Certain devices have ranges that run from minus to plus voltages (eg. -1 to +5 VDC, -10 to +10 VDC,
etc.). The SC4380 Isoverter® II can be set up to accept a bipolar signal input or provide a
bipolar output.
MODELS
SC4130 & SCL4130
CALL TO ORDER:
Isolation: 1500 VAC RMS.
Linearity: 0.1% of full scale.
Drift: ±0.02%/°C typical, ±0.05%/ °C maximum.
Power Supply: SC: 85 to 265 VDC/VAC 50 to 400 Hz;
SCL: 12 to 24 VDC/VAC 50 to 400 Hz.
Output Loads: Current: 600 ohms maximum Voltage: 500 ohms
minimum (20 mA maximum).
Input Characteristics: SC4380: Voltage: 1 megohms impedance,
Current: 10 ohms; SC4151: RTD Search current
< 500 µA; SC4130: 3 megohms impedance.
Case Size: 0.866˝ W (22.5 mm) ⫻ 2.950˝ H (75.0 mm)
⫻ 3.880˝ D (98.5 mm).
Mounting: Mounts on industry standard 35 mm DIN Rail
(DIN EN50022-35).
MODELS
SC4151 & SCL4151
Model SC4151 Range Codes
A = DIN, -100 to 200°C
B = DIN, 0 to 100°C
C = DIN, 0 to 150°C
D = DIN, 0 to 200°F
E = DIN, 0 to 200°C
F = DIN, 0 to 400°F
G = DIN, 0 to 250°C
H = DIN, 0 to 500°F
J = DIN, 0 to 500°C
K = DIN, 0 to 1000°F
Model SCL4151 Range Codes
A = DIN, -100 to 200°C
B = DIN, 0 to 100°C
C = DIN, 0 to 150°C
D = DIN, 0 to 200°F
E = DIN, 0 to 200°C
F = DIN, 0 to 400°F
G = DIN, 0 to 250°C
H = DIN, 0 to 500°F
J = DIN, 0 to 500°C
K = DIN, 0 to 1000°F
MODELS
SC4380 & SCL4380 OPERATING RANGES
Model SC4130 Range Codes
A = J, -100 to 200°C
C = J, 0 to 100°C
D = J, 0 to 500°F
E = J, 0 to 250°C
F = J, 0 to 750°C
G = J, 0 to 1000°F
H = K, -150 to 350°F
J = K, -100 to 200°C
K = K, 0 to 500°F
L = K, 0 to 250°C
M = K, 0 to 1000°F
N = K, 0 to 500°C
P = K, 0 to 2000°F
R = K, 0 to 1000°C
S = T, -300 to 250°F
T = T, -200 to 200°C
SPECIFICATIONS
Model SCL4130 Range Codes
A = J, -100 to 200°C
C = J, 0 to 100°C
D = J, 0 to 500°F
E = J, 0 to 250°C
F = J, 0 to 750°C
G = J, 0 to 1000°F
H = K, -150 to 350°F
J = K, -100 to 200°C
K = K, 0 to 500°F
L = K, 0 to 250°C
M = K, 0 to 1000°F
N = K, 0 to 500°C
P = K, 0 to 2000°F
R = K, 0 to 1000°C
S = T, -300 to 250°F
T = T, -200 to 200°C
U.S. Phone 219 879-8000
•
Inputs
Outputs
Voltage
0 to 100 mV
0 to 200 mV
0 to 500 mV
0 to 1 V
0 to 5 V
0 to 10 V
1 to 5 V
2 to 10 V
Current
0 to 5 mA
0 to 10 mA
0 to 10 mA
0 to 20 mA
0 to 50 mA
0 to 100 mA
1 to 5 mA
4 to 20 mA
10 to 50 mA
Current
0 to 1 mA
0 to 5 mA
0 to 20 mA
1 to 5 mA
4 to 20 mA
Voltage
0 to 1 V
0 to 5 V
0 to 10 V
1 to 5 V
2 to 10 V
All SC4130 & SCL4130 Thermocouple Transmitters
All SC4151 & SCL4151 RTD Transmitters
All SC4380 & SCL4380 Iso-Verter® II ProcessSignal Converter/
Isolators
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
293
Temperature
Linearized and isolated RTD and Thermocouple transmitters
are part of the Series SC4000 Isoverter® II Signal Conditioning Modules. These modules completely isolate the input from the output and
from ground. Compatible with industry standard 35 mm DIN Rail
mount transmitters and isolators, these modules are easily applied in
new or existing installations.
The SC4380 Process Signal Converter/Isolator accepts virtually
all standard process signals as an input, and isolates and retransmits
the signal in either the same units or virtually any other standard
process signal. The SC4380 can be field programmed for reverse or direct action and can receive and transmit single sided or bipolar* signals. Low Voltage units (SCL) are also available.
The SC4151 RTD Transmitters each offer a fixed scale range input
(selected when ordered) and a linearized, isolated, field selectable 4 to
20 mA or 0 to 10 VDC output. Output is selected by simple switch settings. Low Voltage units (SCL) are also available.
The SC4130 Thermocouple Transmitter offers a fixed scale range
input (selected when ordered) and a linearized, isolated, field selectable 4 to 20 mA or 0 to 10 VDC output. Output is selected by simple
switch settings.
Low Voltage units (SCL) are also available.
Series
4130
4151
Temperature
Transmitters
Linearized, Isolated 4-20 mA or 0-10 VDC Outputs, Thermocouple or RTD Inputs
SPECIFICATIONS
Isolation: 1500 VAC RMS.
Linearity: 0.1% of full scale.
Drift: ±0.02% per °C typical, ± 0.05% per °C maximum.
Ambient Operating Temperature: 32 to 131°F (0 to 55°C).
Power Supply: 85-265 VDC/VAC, 50-400 Hz.
Output Loads: Current: 600 ohms maximum.
Voltage: 500 ohms minimum, 20 mA maximum.
Input Characteristics:
4130 (Thermocouple): 3 megohms impedance.
4151 (RTD): Search current <500 µA.
Case Size Including Socket Pins: 2-3/8" W x 3-7/16" H x 1-3/4" D
(60.3 mm W x 87.3 mm H x 44.4 mm D). Height is 2-7/8" (73 mm)
above socket.
Optional Socket
P/N 481-0159
Temperature
Any Model 4130 or 4151 Temperature Transmitter
No. 481-0159 socket for models 4130 or 4151
Iso-Verter® II Transmitters accept thermocouple (4130) or RTD
(4151) inputs, completely isolating them from the output signal and
ground. Output is selectable for your choice of a linearized 4-20 mA or
0-10 VDC signal. These compact modules are compatible with industry
standard octal bases for complete interchangeability.
MODEL CHART 4130 (THERMOCOUPLE TRANSMITTERS)
MODEL CHART 4151 (RTD TRANSMITTERS)
Model
4151A
4151B
4151D
4151E
Type, Range
Model
4151F
4151G
4151H
4151J
Type, Range
DIN,-100 to 200°C
DIN, 0 to 100°C
DIN, 0 to 200°F
DIN, 0 to 200°C
Series
RRT
DIN, 0 to 400°F
DIN, 0 to 250°C
DIN, 0 to 500°F
DIN, 0 to 500°C
Model
Type, Range
Model
4130A
4130D
4130E
4130F
4130G
4130K
J, -100 to 200°C
J, 0 to 500°F
J, 0 to 250°C
J, 0 to 750°C
J, 0 to 1000°F
K, 0 to 500°F
4130L
4130N
4130P
4130R
4130S
4130T
4130U
4130W
T/C Type, Range
K, 0 to 250°C
K, 0 to 500°C
K, 0 to 2000°F
K, 0 to 1000°C
T, -300 to 250°F
T, -200 to 200°C
T, 0-500°F
T, 0-250°C
Remote Reading Thermometer with Switch
31⁄4" Dial, Liquid Actuated Bulb and Capillary Type
SPECIFICATIONS
Remotely monitor and control temperature with this economical, reliable liquid actuated thermometer with integral 5 amp rated snap switch.
The switch setpoint is fully adjustable across the entire temperature range.
Dual scale reads in both °F and °C. Unit is housed in a corrosion protected,
plated steel case with scratch resistant glass window. A bi-metallic element
compensates for temperature effects on the capillary for maximum accuracy. Thermometer includes U-clamp bracket for fast, easy panel mounting.
Mount bulb in any position at any height without affecting temperature
reading.
Wetted Materials: Brass.
Accuracy: ±2% of full scale.
Temperature Limits: -4 to 158°F (-20 to 70°C).
Thermal Effect (Includes Span and Zero): ±1.5% of span per 100°F
(55.6°C) nominal.
Switch Type, Rating: SPDT, 5A @ 250 VAC, non-inductive.
Electrical Connections: (3) male quick connects.
Process Connection: 1/2˝ male NPT.
Dial Size: 3-1/4˝ (80 mm).
Capillary Length: 10.5 ft (3.2 meters).
Bulb Length: 3.0 in (76 mm).
Weight: 1 lb, 4.4 oz.
Agency Approvals: CE.
MODELS
Model Number
RRT2120U
RRT2250U
RRT2300U
294
Range, °F
-40 to 120
32 to 248
0 to 300
VISIT OUR WEBSITES:
Range, °C
-40 to 50
0 to 120
-18 to 149
www.dwyer-inst.com
Suggested Specifications
Remote reading thermometer shall be liquid actuated bulb and capillary type
with dual scale and ±2% of full scale accuracy. Thermometer control mechanism shall be a 5A, SPDT snap action switch. Capillary shall be copper, 101⁄2
feet in length. Thermometer shall be Dwyer Model No. RRT2250U.
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Bi-Metal
Air
Temperature
Switches
Double Adjustable, Heavy Duty, Automatic Reset
Series
M-51
®
®
FEATURES
9
[228.6]
A
UNIVERSAL
MTG. FLANGE
1-15/16
[49.2]
SQ.
MANUAL
RESET
KNOB
3-7/8
1-1/8 [28.6] DIA. [98.4]
• UL Iisted, CSA Certified.
• Automatic or Manual reset.
• SPST mercury switch (SPDT switches available).
• Visible dial shows duct temperature.
• Two adjustments: one sets high temperature
set point, the other sets low temperature reset.
2-1/8
[54]
4-3/4
[120.7]
DIA.
SPECIFICATIONS
7/32 [5.6] DIA. SLOT
4 PLCS.
7/32 [5.6] DIA. SLOT
2 PLCS.
7/8 [22.2] DIA.
CONDUIT OPENING
Designed for use as a limit switch, fan control, or alarm switch, Model M-51 is used on all
types of air conditioning ducts, furnaces, ovens, dryers, etc. Unit may also be used with
damper control system to prevent spread of fire through ducts. Adjustments for both set and
reset points. Visible dial shows duct temperature and switch set points.
MODELS
Model
Number
Switch Action
on Temp. Rise
Range
°F (°C)
Opens
Opens
Opens
Opens
Opens
Opens
25 to 125 (-4 to 52)
25 to 125 (-4 to 52)
50 to 500 (10 to 260)
50 to 500 (10 to 260)
50 to 650 (10 to 343)
50 to 650 (10 to 343)
M-51-71
M-51R-71
M-51-74
M-51R-74
MX-51-75
MX-51R-75
Minimum
Dim. A
Deadband °F(°C) Insertion Length
53⁄8 (136)
53⁄8 (136)
43⁄8 (111)
43⁄8 (111)
43⁄8 (111)
43⁄8 (111)
12 (7)
12 (7)
20 (11)
20 (11)
20 (11)
20 (11)
Series
FM
Switch
Reset
Automatic
Manual
Automatic
Manual
Automatic
Manual
Immersion
Temperature
Control
Visible Setpoint Adjustment, Adjustable Deadband
®
®
A
B
2-1/4
[57.2]
3-3/4
[95.3]
DIA.
3/4 NPT
1-1/16 [27] HEX
7/8 [22.2] DIA.
CONDUIT OPENING
Compact and low cost, Series FM-437 employs a bimetal
element inside an immersion well. Instrument is detachable from the
well, allowing maintenance without draining system. Visible calibrated
dial reduces “start up” time and speeds set point changing. Contacts
are hermetically sealed and mercury wetted. High current (up to 17A)
capacity switches available on special order.
MODELS
Copper Well
Model No.
FM-437-153-3515
FM-437-153-3516
FM-437-153-3510
FM-437-153-3511
FM-437-153-3528
FM-437-153-3529
304SS Well
Model No.
FM-437SS-153-3515
FM-437SS-153-3516
FM-437SS-153-3510
FM-437SS-153-3511
FM-437SS-153-3528
FM-437SS-153-3529
Operating
Temp. Range
°F(°C)
Min
Max
40-200 (5-93)
40-200 (5-93)
80-240 (27-115)
80-240 (27-115)
160-300 (71-149)
160-300 (71-149)
15(8.4)
15(8.4)
15(8.4)
15(8.4)
18(10)
18(10)
160(89)
160(89)
160(89)
160(89)
140(78)
140(78)
Deadband
°F(°C)
Well Dim.
in.(mm)
A
27⁄8"(73)
41⁄2"(114)
27⁄8"(73)
41⁄2"(114)
27⁄8"(73)
41⁄2"(114)
B
23⁄8"(60)
3
⁄4"(19)
23⁄8"(60)
3
⁄4"(19)
23⁄8"(60)
3
⁄4"(19)
SPECIFICATIONS
Service: Compatible liquids or
gases.
Wetted Materials: Well: Copper
or 304 SS.
Temperature Limit: Process:
375° F (190°C), Ambient: 180°F
(82°C).
Pressure Limit: Copper well: 200
psi (13.8 bar) @ 300°F (149°C),
304 SS well: 900 psi (62 bar) @
300°F (149°C).
Enclosure Rating: General
purpose.
Switch Type: SPDT mercury
switch. Optional SPST.
Electrical Rating: 4A @ 120
VAC/DC, 2A @ 240 VAC/DC. 1/8
HP @ 120/240 VAC single phase.
Electrical Connections: Screw
terminal.
Conduit Connection: 7/8˝ (22.23
mm) hole for 1/2˝ (12.7 mm)
conduit hub.
Process Connection: 3/4˝ NPT
male.
Mounting Orientation: Horizontal
and level.
Set Point Adjustment: Internal
moveable pointers for set point and
reset point.
Weight: 2 lb (0.9 kg).
Deadband: Adjustable, see model
chart.
Options: SPST mercury switches
with higher current ratings.
Set Point Scale: Indication in °F
standard. °C optional.
Agency Approvals: UL, FM and
CSA.
FM-437 Models (with copper well) .....................................................
FM-437SS Models (with 304 stainless steel well) ...............................
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
295
Temperature
Service: Compatible gases.
Temperature Limit: Process: range maximum,
Ambient: 180°F (82°C).
Enclosure Rating: General purpose.
Switch Type: SPST mercury switch. Optional SPDT.
Electrical Rating: 10A @ 120 VAC/DC, 5A @ 240
VAC/DC. 3/4 HP @ 120/240 VAC single phase, 1/3 HP
@ 120/240 VDC.
Electrical Connections: Screw terminal.
Conduit Connection: 7/8˝ (22.23 mm) hole for 1/2˝
(12.7 mm) conduit hub.
Process Connection: Mounting flange. Reversible for
flat or curved surfaces.
Mounting Orientation: Horizontal and level.
Set Point Adjustment: Internal moveable pointers for
set point and reset point.
Weight: 5 lb (2.27 kg).
Deadband: Adjustable from minimum in model chart to
full range.
Set Point Scale: Indication in °F standard. °C optional.
Options: SPDT and DPST switches. Switch that closes
on temperature increase.
Agency Approvals: UL and CSA. FM only on models
M-51R-74 and MX-51R-75.
5 R.
[127]
Line
Voltage
Thermostats
Built-in Thermometer, Heavy Duty Construction
Series
860
®
®
SPECIFICATIONS
Service: Compatible gases.
Temperature Limits: -10 to 140°F (-23 to 60°C).
Enclosure Rating: General purpose or explosion-proof rated NEMA 7 & 9, Class I,
Groups C and D; Class II, Groups E, F, and G. CSA approval does not include Group
C.
Switch Type: SPDT or SPST mercury switch. SPST models shown open on
temperature increase. Replace “-2” with “-3” in the model number for close on
increase.
Electrical Rating: SPDT: 4A @ 120 VAC/DC, 2A @ 240 VAC/DC. 1/8 HP @
120/240 VAC single phase. SPST: 10A @ 120 VAC/DC, 5A @ 240 VAC/DC. 3/4 HP
@ 120/240 VAC single phase, 1/4 HP @ 120/240 VDC.
Electrical Connections: General purpose: screw terminal, Explosion-proof: pigtail
leads.
Conduit Connection: General purpose: none, Explosion-proof: 1/2˝ female NPT.
Mounting Orientation: Vertical and level. General purpose unit includes adapter
plate for mounting into a standard wall switch box.
Set Point Adjustment: External knob. Can be removed to prevent tampering.
Weight: General purpose: 1.5 lb (0.7 kg), Explosion-proof: 4.5 lb (2.0 kg).
Deadband: Fixed. Range 65: approx. 4°F (2°C), Other ranges: approx. 2°F (1°C).
Options: SPST mercury switches with higher current ratings. Manual selector switch
for off, auto, and on. Metal thermostat guard.
Set Point Scale: Indication in °F standard. °C optional.
Agency Approvals: UL and CSA.
ADAPTER PLATE
2 HOLES FOR MOUNTING
THERMOSTAT
3-9/32
[83.43]
4-27/32
[123.03]
3-1/8
[79.38]
7/32
[5.56]
3-31/32
[100.81]
2-3/16
[55.56]
2-3/8
7/16
[60.33]
[11.11]
2 HOLES FOR
MOUNTING TO WALL BOX
Temperature
MODELS
Model No.
SPDT
Model No.
SPST
Operating
Range, °F (°C)
Housing
860-153-61
860-153-62
860-153-63
860-153-64
860-153-65
860EH-153-61
860EH-153-62
860EH-153-63
860EH-153-64
860EH-153-65
860-2-61
860-2-62
860-2-63
860-2-64
860-2-65
860EH-2-61
860EH-2-62
860EH-2-63
860EH-2-64
860EH-2-65
25-60 (-4-15)
38-70 (4-21)
56-80 (14-27)
65-90 (18-33)
80-110 (27-43)
25-60 (-4-15)
38-70 (4-21)
56-80 (14-27)
65-90 (18-33)
80-110 (27-43)
Gen. Purp.
Gen. Purp.
Gen. Purp.
Gen. Purp.
Gen. Purp.
Expl. Pr.
Expl. Pr.
Expl. Pr.
Expl. Pr.
Expl. Pr.
Series
DA-7035N
Heavy duty and reliable, Model 860 Line Voltage thermostat is designed for
direct control of motors operating HVAC equipment in industrial environments.
Hermetically sealed mercury switch resists dust, dirt, grease and moisture.
Cadmium plated steel and brass mechanism resists corrosion. Set point is easily adjustable via knurled knob located on the side of the unit. Knob may be removed to prevent tampering. Contacts rated up to 17A available on special
order.
Temperature Switches
Bulb and Capillary, Inert Gas Fill
3/4 [19.05]
CLEARANCE
FOR COVER
REMOVAL
5/8
[15.88]
2-1/4
[57.15]
1-5/8
[41.28]
Ø6-1/64
[152.80]
1/2 CONDUIT
CONNECTION
VIEW #1
MERCOID
CONTROL
2
SEE
[50.80] VIEW #1
Ø17/64 [6.75]
MOUNTING HOLES
TYP 2 PLACES
ADJUSTMENT
SCREWS
7/8
[22.23]
1/4 MALE NPT
PRESSURE CONNECTION
3/4 MALE NPT
BULB CONNECTION
3-5/16
[84.14]
E
MODELS
Model
Number
DA-7035-153-1N
DA-7035-153-3N
DA-7035-153-4N
DA-7035-153-5N
DA-7035-153-7N
DA-7035-153-8N
DA-7035-153-9N
DA-7035-153-10N
DA-7035-153-11N
Maximum
Temp.,
°F (°C)
Range
°F (°C)
-60 to +30 (-50 to 0)
0 to 100 (-18 to 40)
50 to 150 (10 to 65)
100 to 200 (40 to 95)
140 to 300 (60 to 150)
250 to 415 (120 to 215)
350 to 550 (175 to 290)
100 to 300 (40 to 150)
100 to 500 (40 to 260)
150 (65)
240 (115)
250 (120)
300 (150)
500 (260)
550 (290)
600 (315)
500 (260)
600 (315)
Min.
Deadband
°F (°C)
Min. Insertion
Depth
“E” in. (mm)
23 (13)
25 (14)
25 (14)
25 (14)
41 (23)
42 (23)
50 (28)
50 (28)
100 (56)
27⁄8 (73)
27⁄8 (73)
27⁄8 (73)
27⁄8 (73)
27⁄8 (73)
27⁄8 (73)
47⁄8 (124)
27⁄8 (73)
27⁄8 (73)
VISIT OUR WEBSITES:
www.dwyer-inst.com
Service: Compatible liquids or gases.
Wetted Materials: Bulb and connection: 304 SS.
Temperature Limit: Process: see model chart, Ambient: 180°F
(82°C).
Pressure Limit: 300 psi (20.6 bar).
Enclosure Rating: General purpose. Optional weatherproof and
explosion-proof.
Repeatability: ± 1% of full scale.
Switch Type: SPDT snap switch. Optional DPDT snap and a variety
of mercury switches.
Electrical Rating: 15A @ 120/240/480 VAC. 1/8 HP @ 120 VAC
single phase. 0.5A @ 120 VDC resistive, 0.25A @ 240 VDC resistive.
Electrical Connections: Screw terminal.
Conduit Connection: 7/8˝ (22.23 mm) hole for 1/2˝ (12.7 mm)
conduit hub.
Process Connection: 3/4˝ male NPT. Other sizes available.
Mounting Orientation: Vertical and level.
Set Point Adjustment: External knobs for set point and reset point.
Weight: 5 lb (2.3 kg).
Deadband: Adjustable from minimum in model chart to full range.
Optional low fixed deadband.
Capillary: 6 ft (1.8 m) standard. Ranges 1N – 7N, and 10N: copper.
Ranges 8N, 9N, 11N: 304 SS.
Set Point Scale: Indication in °F and °C.
Options: See switch type, see enclosures, fixed deadband, longer or
shorter capillary, armored capillary, wells, two stage, 1/2˝ or 1˝
connection sizes, manual reset, and other bulb styles.
FEATURES
• Adjustable deadband • Snap action switch standard
• Inert gas activated Bourdon tube • No cross ambient
temperature effects • No bulb elevation correction required
• Visible dial calibrated in both °F and °C • Visible on/off
indication
Series DA-7035N temperature switches include the same timeproven switching mechanism used in our Series DA pressure switches. Bourdon tube assures high sensitivity and long life. Fully
adjustable deadband makes units suitable for a wide range of control
applications. Visible, calibrated dial and external adjustments make
changing setpoints simple and fast.
Insertion depth can be increased through use of bulb supports or wells. Consult factory.
296
SPECIFICATIONS
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Temperature Sensors
INTRODUCTION
Sensors measure temperature and pass that information to a
control or monitor. Dwyer offers three types of sensors: thermocouples, resistance temperature detectors (RTDs), and thermistors.
THERMOCOUPLES
Example
A temperature of 100°F at the
measuring junction of a J
Type Thermocouple
produces a voltage
difference of 2.0 millivolts.
RTDs
RTDs are usually platinum wire wound on a glass or ceramic
bobbin and sealed with a coating of ceramic or glass. They can
also be made by depositing platinum as a film on a substrate and
then encapsulating it. The electrical resistance of the RTD
changes as a function of temperature. Circuitry similar to a
Wheatstone bridge is built into controls designed for use with
RTDs. Constant current into the bridge produces an output
voltage that varies with temperature. Lead wire resistance can
significantly affect the RTD measurement. This is typically corrected using a third (compensating) lead wire. See Figures 3
and 4.
Extension wires used with RTDs may be plain copper wire.
RTDs are generally more accurate and more stable over time
than thermocouples. Dwyer RTDs are built to rigorous DIN
(most common) or NIST standards and are offered in a wide variety of standard configurations.
The third wire in the 3-wire
RTD compensates for the
wire lead resistance and
its’ temperature change.
THERMISTORS
Thermistors have a semiconductor material which changes its
electrical resistance as a function of temperature. Extension
wires used with thermistors can be plain copper wire.
Thermistors offer accuracy similar to RTDs within narrow temperature ranges near ambient temperature. They also generally offer faster response times. Since thermistor standards vary,
care must be taken to match the instrumentation to the sensor.
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
297
Temperature
Thermocouples are made of two dissimilar metal wires joined
at their measuring end forming the “measuring junction” also
known as the “hot junction”. A small voltage, known as the Seeback voltage, is created at a junction of dissimiliar metal alloys.
This voltage changes as a function of temperature. See Figure
1. The control or monitor measures this small voltage and converts it to a temperature signal. Modern instrumentation also
measures the temperature where the thermocouple is connected to the instrument. This is the reference junction. See Figure
2. Any temperature effects near the instrument can be cancelled out leaving an accurate reading of the process to be measured.
A thermocouple may be directly connected to a control or monitor. Extension wires, if used, must be of the same materials as
the thermocouple wires.
Thermocouples designed with their measuring junctions in contact with new surfaces are known as grounded junction thermocouples. These are the most common, generally have the
fastest response times, and are the most economical. Ungrounded junction thermocouples offer the advantage of electrical isolation. Dwyer manufactures both types of
thermocouples. Thermocouples are generally more rugged and
less expensive than other sensor types. All Dwyer thermocouples are manufactured using industry standard alloys and meet
stringent ANSI standards. This assures interchangeability
with other standard thermocouples without special instrument
recalibration.
Dwyer thermocouples are used in all types of applications, can
measure wide temperature ranges, and are offered in a large variety of standard configurations.
Temperature Sensors
Temperature
ORDERING SENSORS:
Sensors are constructed with various types of
protection/mounting hardware, extensions, and wire terminations. The sensor types and their temperature ranges are
shown in the table below. See “Temperature Limits” below for
maximum service temperatures applicable to the protection
tube, mounting hardware, wire extensions, etc.
This section shows only a limited selection of the available sensors. The sensors are organized by hardware type. Most hardware can house any type thermocouple, RTD, or thermistor.
Terminations are usually either lug type or standard plugs, but
many other types are available. Various ‘head enclosures’ are
also available. Dimensions can be custom designed to meet your
specifications. The selections listed are the most popular configurations. Please ask your sales representative about other
possible selections.
Thermocouple
Wire
Types
Type
J
Iron/Constantan
K
Chromel/Alumel
E
Chromel/Constantan
T
Copper/Constantan
R
Plat. 13% /Rhod. Plat.
S
Plat. 10% Rhod./Plat.
B
Plat. 6% Rhod./Plat. 30% Rhod.
Thermistor Types
Cal. 100
2K @ 25°C
Cal. 101
5K @ 25°C
Cal. 109
100K @ 25°C
RTD Types
DIN (1001 @ O°C a = .00385 1/1/°C)
NIST (1001 @ O°C a = .00392 1/1/°C)
Nickel (1201 @ O°C a = .00672 1/1/°C)
298
Temperature
Range (°F)
32 to 1400
32 to 2300
-300 to 1600
-300 to 700
32 to 2700
32 to 2700
1600 to 3100
Temperature
Range (°C)
0 to 760
0 to 1200
-184 to 871
-184 to 371
0 to 1482
0 to 1482
871 to 1704
-60 to 150
50 to 250
300 to 600
-51 to 66
10 to 121
140 to 315
-420 to 1500
-420 to 1500
-150 to 600
-200 to 875
-200 to 875
-101 to 315
VISIT OUR WEBSITES:
www.dwyer-inst.com
TEMPERATURE LIMITS:
Sensor selection depends on two separate temperatures:
process temperature and connector temperature. Make sure
the local temperature at each component does not exceed the
maximum rated service temperature for that component. Note
that extension wire must withstand the process temperature.
All Dwyer thermocouple and RTD assemblies (including extension wire) shown in this section are designed for process temperatures to at least 900°F. Please consult factory if higher
service temperatures are needed.
SERVICE TEMPERATURES
Stainless Steel Tubing / Protection /
Mounting Hardware ..................................................1500°F
Stainless Steel springs ................................................1500°F
Inconel® Springs (Dwyer Standard) .............................2100°F
Fiberglass insulated extension wire (Dwyer Standard) ..900°F
Junction Box (BX) connector ........................................400°F
Plug ...............................................................................300°F
J Type Thermocouple Junction ....................................1600°F
K Type Thermocouple Junction ...................................2500°F
E Type Thermocouple Junction ...................................1800°F
DlN or NlST RTD ..........................................................1607°F
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Thermocouples & RTD’s
GENERAL PURPOSE
Basic Model
Rigid Extension Model
MODEL
SENSOR TYPE
TERMINAL
122095-84
122095-01
122095-04
J
K
(3-wire) 1001 RTD
Lug
Lug
Lug
MODEL
SENSOR TYPE
A LENGTH
TERMINAL
122095-96
122095-07
122095-08
122095-14
122095-00
122095-10
J
J
J
1001RTD
J
J
12
18
24
24
12
18
Open
Open
Open
Open
Plug
Plug
Teflon® Insulation Extension
MARK RED LEAD "-"
.250 OD STAINLESS STEEL TUBE
6.000
MARK WHITE LEAD "+"
4.000
36.000
MODEL
SENSOR TYPE
A LENGTH
TERMINAL
122087-00
122087-01
122087-02
1001RTD
1001RTD
1001RTD
6˝
12˝
18˝
Lug
Lug
Lug
Temperature
#6 SPADE TERMINAL
TYP 3 PLACES
TEFLON INSULATED WIRE
WITH SEALED TIP
Flex Hose Extension Model
MODEL
SENSOR TYPE
BEND
TERMINAL
122095-06
122095-15
122095-17
122095-16
122095-20
J
J
1001 RTD
J
1001 RTD
0°
0°
0°
90°
90°
Lug
Plug
Lug
Lug
Lug
Stainless Steel Overbraid Extension Model
MODEL
SENSOR TYPE
BEND
TERMINAL
122095-19
122095-21
122095-22
122095-25
J
J
J
1001 RTD
0°
0°
90°
0°
Lug
Plug
Lug
Lug
MODEL
SENSOR TYPE
WASHER SIZE
TERMINAL
122095-24
122095-31
122095-32
J
J
J
13/32˝ ID
13/32˝ ID
13/64˝ ID
(#10 Washer)
Lug
Plug
Lug
MODEL
SENSOR TYPE
TIP
A LENGTH
TERMINAL
122095-58
122095-57
122095-60
122095-59
J
J
J
J
Flush
Flush
1/8˝
1/8˝
0
4˝
0
4˝
Plug
Plug
Plug
Plug
SPECIAL PURPOSE
Surface Thermocouple (900°F Max.)
Bolt Style
1/2-20 UNF-2A
3.000
CALL TO ORDER:
STANDARD PLUG
FIBERGLASS INSULATED WIRE
WITH STAINLESS STEEL FLEX HOSE
A
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
299
Thermocouples & RTD’s
SPECIAL PURPOSE
Web Style
MODEL
A LENGTH
TERMINAL
122095-35
122095-86
122095-34
122095-85
4˝
2.75˝
4˝
2.75˝
No
No
Yes
Yes
BAYONET MOUNT
Adjustable Length Spring Type
Temperature
A
MODEL
SENSOR TYPE
A LENGTH
TERMINAL
122095-75
122095-26
122095-77
122095-76
122095-27
122095-78
J
J
J
J
J
J
36
48
60
36
48
60
Lug
Lug
Lug
Plug
Plug
Plug
Adjustable Length Flex Hose Type
A
MODEL
SENSOR TYPE
A LENGTH
TERMINAL
122095-79
122095-81
122095-82
122095-80
122095-29
122095-83
J
J
J
J
J
J
36
48
60
36
48
60
Lug
Lug
Lug
Plug
Plug
Plug
MINERAL INSULATED
Mineral Insulated
#6 SPADE TERMINAL
TYP 3 PLACES
.375 OD 304 STAINLESS STEEL
POTTING ADAPTOR. POTTING ADAPTOR
AND POTTING COMPOUND MUST WITHSTAND
500°F CONTINUOUS TEMPERATURE.
.250 OD 304 STAINLESS
STEEL SHEATH
MARK RED LEAD "_"
FIBERGLASS INSULATED WIRE
WITH SEALED TIP
MARK WHITE LEAD "+"
6.000
300
VISIT OUR WEBSITES:
36.000
4.000
www.dwyer-inst.com
•
MODEL
SENSOR TYPE
122088-00
122088-01
122086-00
100ΩRTD
100ΩRTD
100ΩRTD
www.dwyer-inst.co.uk
•
A LENGTH DIAMETER
6˝
12˝
6˝
1/4
1/4
1/8
www.dwyer-inst.com.au
TERMINAL
Lug
Lug
Lug
Term Descriptions
HARDWARE TYPE
Plain Sheath
Bayonet Mount, Adjustable (min. A = 0.5˝)
(when made with Flex Hose)
Bayonet Mount, Adjustable
(when made with SS Overbraid Wire)
Bayonet Mount, Fixed (min. A = 1.8˝)
Temperature
TERMINALS
Stripped-Ends-Type 0
RTD Standard Plug - Type 3
Lugs - Type 1
RTD Standard Jack - Type 4
Fast Tabs w/ BX
Connector - Type A
Thermoplastic Head Type B
Lugs w/BX Connector Type 2
T/C Mini Plug - Type 6
T/C Standard Plug - Type 3
T/C Mini Jack - Type 7
T/C Standard Jack - Type 4
General Purpose Head Type 8
Open Terminals - Type 5
Fast Tabs - Type 9
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
RTD Mini Plug - Type 6
RTD Mini Jack - Type 7
•
Asia Pacific Phone 61 2 4272-2055
301
General Purpose and Bayonet Type Thermocouples & RTD’s
General Purpose Type Thermocouples and RTD’s have a plain sheath with no permanently attached fittings. They are usually
mounted with the use of a compression fitting which is supplied separately. Tip temperatures can be as high as 480°C (900°F) for
fiberglass insulated wire, 250°C (500°F) for teflon insulated wire. Models specified with a head cover include a 1/2˝ hex nipple. For
higher temperatures see the section on Mineral Insulated Probes.
Bayonet
General Purpose
AA
AA
AA
AA
A
A
A
45°
Bend
90°
Bend
90°
Bend
A
45°
Bend
FIXED
B
A
C
AA
Temperature
A
B
C
ADJUSTABLE
B
C
Model Coding For General Purpose & Bayonet Styles
Fill in the appropriate numbers or letters to specify the probe of your choice. Fill in all boxes. If an item or dimension does not apply, fill
those boxes with zeros ‘0’.
A
in 1/10 inch
5
SENSOR TYPE
J (T/C)
K (T/C)
E (T/C)
T (T/C)
6 (RTD DIN)
4 (RTD NIST)
Z (RTD DIN 1K)
5 (RTD DIN 2-Wire)
7 (RTD DIN 1K
2-Wire)
HARDWARE TYPE
0 - None
1 - Plain Sheath
4 - Type 1 with TFL*
6 - Bayonet Mount Adjustable, SS
7 - Bayonet Mount Fixed Length, SS
302
EXTENSION TYPE
0 - No extension
1 - Fiberglass
Insulation
3 - Stainless Steel
Overbraid
4 - TFL Insulation
5 - Stainless Steel
Flex Hose
6 - TFL over SS
Flex Hose
ELEMENTS
1 - Single
SENSOR TERMINALS
2 - Dual
0 - Stripped Ends
1 - Lugs
2 - Lugs with BX
3 - Standard Plug
4 - Standard Jack
5 - Open Terminals
6 - Mini Plug
7 - Mini Jack
8 - Snap Cover Head, AI
9 - Fastabs
A - Fastabs with BX
B - Snap Cover Head, Plastic
E - Screw Cover Head, AI w/ 3/4
NPT Conduit
F - Screw Cover Head, Plastic w/
3/4 NPT Conduit
G - SS Weather Proof Head w/ 1/2
NPT Conduit
VISIT OUR WEBSITES:
www.dwyer-inst.com
B
in inches
-
-
-
AA
in 1/10 inch
•
-
JUNCTION TYPE
1 - Grounded
2 - Ungrounded
3 - Exposed Tip
C
in inches
-
SENSOR O.D.
0 - None
2 - 1/8˝*
3 - 3/16˝
4 - 1/4˝*
BEND
1 - Straight
2 - 45°
3 - 90°
*Not available for RTD’s with Bayonet Fittings.
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Sensors for Extruders and Plastic Machines
INJECTION MOLDING NOZZLE TYPE
In-Melt type thermocouples and RTD’s are designed to bolt into the injector nozzle and sense the temperature of the melt directly, and is rated to
450°C (900°F). The standard 3/8˝ hex head stainless steel body has 3/8-24 NFT threads. The sensor tip extends 1/8˝ beyond the end of the bolt
assembly. Specify your requirements from the Order Chart below.
Not In-Melt type thermocouples and RTD’s are designed to screw into a blind hole in the nozzle, and is rated to 450°C (900°F). The standard 1/4
NFT thread fits most standard nozzles. Specify your requirements from the Order Chart below.
Not In-Melt Type
In-Melt Type
EXTRUDER BOLT TYPE
A
B
Bolt Length
Bolt Type with Flex
Model Coding
Fill in the appropriate numbers or letters to specify the probe of your choice. Fill in all boxes. If an item or
A
B
dimension does not apply, fill those boxes with zeros ‘0’.
in 1/100 inch
ELEMENTS
J (T/C)
K (T/C)
6 (RTD DIN)
4 (RTD NIST)
Z (RTD DIN 1K)
5 (RTD DIN 2-Wire)
7 (RTD DIN 1K 2-Wire)
HARDWARE TYPE
CALL TO ORDER:
C
in inches
JUNCTION TYPE
SENSOR TYPE
1 - Not In-Melt
2 - In-Melt
3 - Bolt - 3˝ long
4 - Bolt - 4˝ long
6 - Bolt - 6˝ long
-
0 -
-
6
in inches
EXTENSION TYPE
SENSOR TERMINALS
0 - No extension
1 - Fiberglass
Insulation
3 - Stainless Steel
Overbraid
5 - Stainless Steel
Flex Hose
0 - Stripped Ends
1 - Lugs
2 - Lugs with BX
3 - Standard Plug
4 - Standard Jack
6 - Mini Plug
7 - Mini Jack
9 - Fastabs
A - Fastabs with BX
U.S. Phone 219 879-8000
•
1 - Single
2 - Dual
U.K. Phone (+44) (0)1494-461707
•
1 - Grounded
2 - Ungrounded
Asia Pacific Phone 61 2 4272-2055
303
Temperature
Designed for direct mounting into extruder barrels, the Bolt Type thermocouples and RTD’s offer easy interchangeability. Standard configuration
has a 1/4 inch penetration into the barrel, and industry standard 1/2-20 NF thread. Order options allow barrel penetrations of 0 inches (flush) to
1 inch in 1/100th inch increments (specify as A dimension) and flex extension in 1 inch increments (specify as B dimension). See Special Order
Chart below for more details.
Protection Tube Assemblies and Replacement
Thermocouple Elements
Protection tube assembly type thermocouples are designed for high temperature applications such as ovens, kilns, or other processes. Metal protection tubes can be used in applications ranging from 1200°F to 2100°F. Ceramic tubes can be used in applications
from 1210°F to 4100°F.
AA
A
B
90°
Elbow
A
Temperature
Welded Bushing
REPLACEMENT SENSOR ELEMENTS
Replacement sensor elements are available as separate parts. All rules regarding lengths and fittings apply. Use the standard
Order Code, using a ‘0’ for the tube type, ‘0’ for mounting, ‘0’ for sensor terminals, and ‘0’ for protection tube. See example
below.
To order use Order Chart below. Specify “0” for Tube Type.
(e.g. - Type K 8 ga. insulated element 12˝ long is 7K000-110121-12-02-00).
To order use Order Chart below. Specify “0” for Tube Type.
(e.g. - Type K 14 ga. bare element 12˝ long is 7K000-110-31112-02-00).
Model Coding
Fill in the appropriate numbers or letters to specify the probe of your choice. Fill in all boxes. If an item or
dimension does not apply, fill those boxes with zeros ‘0’.
A
AA
7
-
-
*
**
HARDWARE TYPE
0 - None
1 - 304 SS
2 - 316 SS
4 - Inconel® 601
5 - Mullite+
6 - Alumina+
B - Carbon Steel
304
ELEMENTS
PROTECTION TUBE
MOUNTING TYPE
1 - Single
2 - Dual
SENSOR TERMINALS
1 - Straight
2 - 45°
3 - 90°
Metal/Ceramic
0 - None/None
1 - 1/4˝ pipe/None
2 - None/0.375˝ OD
3 - None/0.687˝ OD
4 - 1/2˝ pipe/None
5 - 3/4˝ pipe/0.750˝ OD
6 - None/1.125˝ OD
7 - 1˝ pipe/None
0 - None
0 - No mounting
1 - Snap Cover, Aluminum Head
1 - Sleeve and Flange
2 - Weatherproof Screw Cover
2 - Bushing 3/4 NPT
Aluminum Head.
3 - Bushing 1 NPT
*Wire Gauge
4 - Bushing 1-1/4 NPT
** Insulators
1-8
5 - SS Bushing 3/4 NPT
1 - None
3 - 14
6 - SS Bushing 1 NPT
2 - Oval (14 ga wire or larger)
5 - 20
7 - SS Bushing 1-1/4 NPT
3 - Round (18 ga wire or smaller)
6 - 24
7 - 30
+ Length in 6˝ increments
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
B
in inches
in inches
1 BEND
SENSOR TYPE
J (T/C)
K (T/C)
in inches
www.dwyer-inst.com.au
-
Mineral Insulated Thermocouples and RTD’s
Mineral Insulated Thermocouples and RTDs are known for their excellent mechanical durability and resistance to electrical breakdown. Available
in outside diameters from 0.020 inch (0.5mm) to 0.500 inch (12.7mm), Mineral Insulated Thermocouples can be bent to most any angle without special equipment. Because of its flexibility, the mineral insulated material can be made to extremely long lengths, coiled for inexpensive shipment,
and straightened upon arrival without damage.
Ungrounded and exposed junctions are electronically isolated from the sheath. Minimum resistance is 1.5 megohms at 500 VDC.
Due to the varying sized of connection wire and cable, a transition fitting is used between the cold end of the sheath and the connecting wires. This
fitting measures 1-1/4˝ long by 1/4˝ outside diameter for 1/8˝ or smaller sheaths, and 1-1/2˝ long by 3/8˝ outside diameter for 3/16˝ and 1/4˝
sheaths. Larger sheaths are usually connected to bushings or connector heads, and usually do not require transition fittings. Sheaths terminating
in connectors other than wire or cable do not require transition fittings.
B
A
C
MINERAL INSULATED TRANSITIONS
Sheath and Transition Fitting
(when made with Flex Hose)
Sheath and Transition Fitting
(when made with SS Overbraid Wire)
Sheath and Transition Fitting
(when made with Fiberglass Wire)
Temperature
Basic Sheath Configuration
Model Coding
Fill in the appropriate numbers or letters to specify the probe of your choice. Fill in all boxes. If an item or
dimension does not apply, fill those boxes with zeros ‘0’.
A
in 1/10 inch
8
-
-
SENSOR TYPE
J (T/C)
K (T/C)
E (T/C)
T (T/C)
6 (RTD DIN)
4 (RTD NIST)
Z (1K RTD DIN)
5 (RTD DIN 2-Wire)
7 (RTD DIN 1K
2-Wire)
HARDWARE TYPE
1 - 304 SS Sheath
2 - 316 SS Sheath
3 - Inconel 600 Sheath
EXTENSION TYPE
0 - No extension
1 - Fiberglass
Insulation
3 - Stainless Steel
Overbraid
4 - TFL Insulation
5 - SS Flex Hose
6 - TFL over SS
Flex Hose
CALL TO ORDER:
ELEMENTS
1 - Single
SENSOR TERMINALS
2 - Dual
0 - Stripped Ends
1 - Lugs
2 - Lugs with BX
3 - Standard Plug
4 - Standard Jack
5 - Open Terminals
6 - Mini Plug
7 - Mini Jack
8 - Snap Cover, AI Head
9 - Fastabs
A - Fastabs with BX
B - Snap Cover, Plastic Head
C - 3/4 NPT Hex Threaded End
D - 3/4 NPT Hex Nipple
E - Screw Cover, AI Head w/ 3/4
NPT Conduit
F - Screw Cover, Plastic Head w/
3/4 NPT Conduit
G - SS Weatherproof Head w/ 1/2
NPT Conduit
H - 1/2 NPT Hex Nipple
U.S. Phone 219 879-8000
•
AA
in 1/10 inch
-
B
in inches
-
JUNCTION TYPE
1 - Grounded
2 - Ungrounded
3 - Exposed
U.K. Phone (+44) (0)1494-461707
•
C
in inches
-
SENSOR O.D.
1 - 1/16˝
2 - 1/8˝
3 - 3/16˝
4 - 1/4˝
5 - 3/8˝
Asia Pacific Phone 61 2 4272-2055
BEND
1 - None
2 - 45°
3 - 90°
305
Special Application Thermocouples and RTD’s
Special Application Thermocouples and RTD’s cover a wide variety of types and configurations. This section covers Teflon® covered
thermocouples and RTD’s in rigid and flexible types, ring type thermocouples and RTD’s for surface measurement, web type
thermcouples for surface measurement of moving objects such as rollers, and penetration thermocouples and RTD’s with sharp tips
for measurement of viscous liquids and semisolids such as tar and heavy oil, and other material such as frozen food and meat.
Flexible Teflon® Covered Bead Junction
Penetration Type Thermocouples and RTD’s
AA 1-1/4˝
A
B
B
C
Standard Style
with Transition
Fitting
Web Type Surface Thermocouples
A
AA 1-1/4˝
A
B
“D” Handle Style
Temperature
Web Type Surface Thermocouple
Replacement Element
Ring Type Surface Thermocouples and RTD’s
B
C
Web Type Surface
Thermocouple Assembly
Model Coding
Fill in the appropriate numbers or letters to specify the probe of your choice. Fill in all boxes. If an item or
dimension does not apply, fill those boxes with zeros ‘0’.
A
in 1/10 inch
9
SENSOR TYPE
J (T/C)
K (T/C)
E (T/C)
T (T/C)
6 (RTD DIN)
4 (RTD NIST)
Z (RTD DIN 1K)
HARDWARE TYPE
5 - Teflon® Covered
Bead Junction
6 - Ring #10 (0.187 od)
7 - Ring #8 (0.156 od)
8 - Ring 13/32˝
9 - Web
A - Penetration Probe
B - Penetration Probe
with ˝D˝ Handle
306
-
EXTENSION TYPE
0 - No extension
1 - Fiberglass
Insulation
3 - Stainless Steel
Overbraid
4 - TFL Insulation
5 - Stainless Steel
Flex Hose
6 - TFL over SS
Flex Hose
VISIT OUR WEBSITES:
AA
in 1/10 inch
-
-
ELEMENTS
1 - Single
SENSOR TERMINALS
2 - Dual
0 - None
1 - Lugs
2 - Lugs with BX
3 - Standard Plug
4 - Standard Jack
5 - Open Terminals
6 - Mini Plug
7 - Mini Jack
9 - Fastabs
A - Fastabs with BX
www.dwyer-inst.com
•
B
in inches
-
JUNCTION TYPE
1 - Grounded
2 - Ungrounded
3 - Exposed
www.dwyer-inst.co.uk
•
C
in inches
-
SENSOR O.D.
0 - N/A
2 - 1/8˝
3 - 3/16˝
4 - 1/4˝
www.dwyer-inst.com.au
Sensors for Sanitary Applications
STAINLESS STEEL
CONNECTION HEAD
1.00
STANDARD WHITE POLYPROPYLENE SNAP-COVER CONNECTION HEAD
2.00
.840˝ SST SUPPORT TUBE
1/2˝ CONDUIT
CONNECTION
A
2.25
SANITARY WELD
SANITARY CAP
SANITARY CAP
3˝ NOM.
3/4˝ CONDUIT
CONNECTION
WHITE POLY
SCREW COVER
CONNECTION HEAD
.405 SST SUPPORT TUBE
MINIATURE ALUMINUM CONNECTION HEAD
3/4˝ CONDUIT CONNECTION
PG9 CABLE GLAND
STANDARD WHITE POLYPROPYLENE SNAP-COVER CONNECTION HEAD
CHEMICAL RESISTANT STRAIN RELIEF
.50˝ SST SUPPORT TUBE
.840˝ SST SUPPORT TUBE
TEFLON JACKETED CABLE
A
A
1˝
SANITARY WELD
SANITARY WELD
SANITARY CAP
3˝ NOM.
Temperature
3˝ NOM.
B
C
SANITARY CAP
3/4˝ CONDUIT CONNECTION
16A BEVEL SEAT
16 AMP CLAMP CAP
Size
Tube O.D.
1/2 or 3/4
1
1-1/2
2
2-1/2
3
O.D.
Thickness
1.00
1.98
1.98
2.51
3.03
3.57
.188
.25
.25
.25
.25
.25
Size
Tube O.D.
1
1-1/2
2
2-1/2
3
16APV APC
O.D.
Thickness
1.31
1.84
2.37
2.90
3.43
.46
.56
.62
.66
.71
MODEL CODING:
D
-
Size
Tube O.D.
1
1-1/2
2
2-1/2
3
A
in 1/10 inch
-
16 AI-14I I-LINE
O.D.
Thickness
1.38
1.88
2.38
2.88
3.38
.29
.42
.46
.47
.50
B
in inches
-
Size
Tube O.D.
1
1-1/2
2
2-1/2
3
O.D.
Thickness
2
2
2.65
3.12
3.87
.50
.50
.56
.56
.75
C
in inches
-
SENSOR TYPE
J (T/C)
K (T/C)
E (T/C)
T (T/C)
6 (RTD DIN)
4 (RTD NIST)
CAP STYLE
2 - 16A Without Nut
3 - 16A With Nut
4 - 16AI-14I
5 - 16 Amp
6 - 16 APV Without Nut
7 - 16 APV With Nut
CAP SIZE
1 - 1/2˝
2 - 3/4˝
3 - 1-1/2˝
4-2˝
5 - 2-1/2˝
6 - 3˝
SHEATH
1 - Straight
3 - Stepped Tip
CALL TO ORDER:
U.S. Phone 219 879-8000
•
TERMINATION
ELEMENTS
1 - Single
0 - No Termination
1 - White Snap Cover PP Head 2 - Dual
(3/4˝ Conduit)
2 - White Screw Cover PP
Head (3/4˝ Conduit)
3 - Screw Cover 316SS Head
(1/2˝ Conduit)
4 - Split Leads
5 - Split Leads With Lugs
6 - Split Leads With BX & Lugs
7 - STD Plug
8 - STD Jack
9 - Miniature Aluminum Snap
Cover Head
U.K. Phone (+44) (0)1494-461707
•
JUNCTION TYPE
1 - Grounded
2 - Ungrounded
Asia Pacific Phone 61 2 4272-2055
SENSOR O.D.
NOMINAL/REDUCED
1 - 5/32˝ / NA
3 - 3/8˝ / 3/16˝
6 - 1/4˝ / NA
7 - 1/2˝ / NA
307
Series P Penetration Probes
Monitor internal temperature of poultry, meat, fish, dough, and other fresh or slightly frozen food products. The Series P probes
can also be used to penetrate soft process materials such as plastic compounds and rubber. The probes are constructed entirely of
FDA compliant materials for use in sanitary applications.
Probe Styles
1
"A"
1
"C"
"B"
1. Transition Fitting
STRAIN RELIEF TUBING
POINTED CLOSURE
TRANSITION FITTING
"A"
1-1/2
2-1/2
"B"
"C"
"B"
"C"
2. Straight Handle
STRAIGHT HANDLE
"A"
2-3/8
1-3/4
1-1/2
3. Saber Handle
Temperature
SABER HANDLE
"A"
2-1/2
1-1/2
"B"
"C"
4. Flanged Handle
FLANGED HANDLE
2-1/2
"A"
6&7. Euro Style Handle
(Teflon or Stainless Steel)
"B"
EURO STYLE
Model Coding - Series P Penetration Probes
Fill in the appropriate numbers or letters to specify the probe of your choice. Fill in all boxes. If an item or
dimension does not apply, fill those boxes with zeros ‘0’.
A dim.
1/10 inch
-
P
SENSOR TYPE
J (T/C)
T (T/C)
6 (RTD DIN)
4 (RTD NIST)
Z (RTD DIN 1K)
EXTENSION TYPE
4 - TFL Insulation
6 - TFL over SS flex
hose
B dim.
inches
-
-
-
JUNCTION
1 - Grounded
2 - Ungrounded
SENSOR TERMINALS
0 - Stripped Ends
1 - Lugs
2 - Lugs with BX
3 - Standard Plug
4 - Standard Jack
6 - Mini Plug
7 - Mini Jack
C dim.
inches
SENSOR O.D.
7 - 0.134 OD hypodermic
8 - 0.180 OD hypodermic
PROBE STYLE
1 - Standard transition fitting, SS
2 - Straight handle, SS
3 - Saber handle, SS
4 - Flanged handle, SS
6 - Euro Style, white teflon
7 - Euro Style, SS
308
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
"C"
Temperature Sensor Assemblies with Thermowells
Series T Sensor Assemblies are available in a variety of head styles and thermowell materials. All elements are spring loaded to
ensure positive contact in the thermowell. Thermowells are non-lagging. The sensor sheath material is constructed of 316 stainless
steel regardless of the well material specified.
"A"
"A"
HEX
EXTENSION
NIPPLE
EXTENSION
THERMOWELL
THERMOWELL
CONNECTION HEAD
CONNECTION HEAD
"A"
Temperature
THERMOWELL
UNION
EXTENSION
CONNECTION HEAD
Model Coding - Sensor Assemblies with Thermowells
Fill in the appropriate numbers or letters to specify the probe of your choice. Fill in all boxes. If an item or
dimension does not apply, fill those boxes with zeros ‘0’.
A
in inches
-
-
T
SENSOR TYPE
J (T/C)
K (T/C)
E (T/C)
T (T/C)
6 (RTD DIN)
4 (RTD NIST)
Z (RTD DIN 1K)
TAPER AND BORE
0 - Straight/0.260
1 - Step/0.260
2 - Straight/0.390
3 - Taper/0.260
4 - Taper/0.390
WELL MATERIAL
1 - 304 SS
2 - 316 SS
3 - Brass
EXTENSION
1 - Steel 1/2 NPT 1 in hex
4 - Steel 1/2 NPT 4 in nipple
7 - Steel 1/2 NPT 4 in union
A - 304 SS 1/2 NPT 1 in hex
D - 304 SS 1/2 NPT 4 in nipple
G - 304 SS 1/2 NPT 4 in union
K - 316 SS 1/2 NPT 1 in hex
N - 316 SS 1/2 NPT 4 in nipple
S - 316 SS 1/2 NPT 4 in union
U.S. Phone 219 879-8000
HEAD
0 - Aluminum Screw
Cover
1 - Cast Aluminum Snap
Cover
2 - Polypropylene Snap
Cover
3 - Polypropylene Screw
Cover
4 - Explosion Proof+
5 - 304 SS Weather
Proof
+Explosion-proof head meets the following:
Class I, Groups C & D
Class II, Groups E, F & L
Class III, Div 1 & 2
NEMA 7, Groups C & D
NEMA 9, Groups E, F, & L
A dimension is available in lengths of 4, 6, 9,
12, 15, 18, and 24 inches only.
CALL TO ORDER:
ELEMENTS
1 - Single
2 - Dual
•
U.K. Phone (+44) (0)1494-461707
•
SHEATH O.D.
Nominal/Reduced
1 - 5/8˝ / 1/2˝
4 - 3/4˝ / 1/2˝
6 - 7/8˝ / 1/2˝
7 - 7/8˝ / 5/8˝
8 - 1-1/16˝ / 5/8˝
9 - 7/8˝ / 49/64˝
A - 1-1/16˝ / 49/64˝
B - 5/8˝ straight
C - 49/64˝ straight
D - 7/8˝ straight
E - 3/4˝ straight
Asia Pacific Phone 61 2 4272-2055
309
Thermowells
Select bore as 0.260 for 1/4˝ diameter elements and 0.390 for 3/8˝ diameter elements. Specify
heavy duty mounting for tapered sheaths.
TAPERED FLANGED
STRAIGHT STEM
1/4
(6.35)
"A"
1/4
(6.35)
"A"
.260
(6.60)
BORE
WELD
1/2 NPT
SHEATH
.260/.390
(6.60)/(9.91)
BORE
1/2
(12.70)
5/8
(15.88)
1-1/4
(31.75)
1/2 NPT
49/64
(19.45)
STEPPED STEM
1/4 IN ELEMENTS ONLY
3/4
(19.05)
TAPERED STEM
1.000
(25.40)
TAPERED STEM
2-1/4
(57.15)
1/4
(5.35)
"A"
0.260/0.390
(6.60)/(9.91)
BORE
5/8
(15.88)
STRAIGHT FLANGED
49/64
(19.45)
Temperature
1/2 NPT
1/4
(6.35)
"A"
3/4
(19.05)
TAPERED STEM
1.000
(25.40)
WELD
1/2 NPT
SHEATH
STEPPED STEM
1-1/4
(31.75)
1/4
(6.35)
"A"
.260/.390
(6.60)/(9.91)
BORE
.260
(6.60)
BORE
STRAIGHT STEM
1/2
(12.70)
2-1/4
(57.15)
1/2 NPT
STEPPED STEM
1/4 IN ELEMENTS ONLY
3/4
(19.05)
1.000
(25.40)
Model Coding - Thermowells
Fill in the appropriate numbers or letters to specify the thermowell of your choice. Fill in all boxes. If an item or
dimension does not apply, fill those boxes with zeros ‘0’.
W
HARDWARE TYPE
1 - 304 SS Sheath
2 - 316 SS Sheath
3 - Brass
4 - Carbon Steel
310
-
INSIDE THREAD
1 - 1/2˝ female NPT
TAPER AND BORE
0 - Straight / 0.260
1 - Step / 0.260
2 - Straight / 0.390
3 - Taper / 0.260
4 - Taper / 0.390
VISIT OUR WEBSITES:
-
A Dimension Specify in 4, 6, 9, 12,
15, 18, 0r 24˝
PROCESS CONNECTION
1 - 1/2 NPT
2 - 3/4 NPT
3 - 1 NPT
4 - 1˝ 150# Flange
5 - 1-1/2˝ 150# Flange
6 - 2˝ 150# Flange
7 - 1˝ 300# Flange
8 - 1-1/2˝ 300# Flange
9 - 2˝ 300# Flange
A - 1˝ 600# Flange
B - 1-1/2˝ 600# Flange
C - 2˝ 600# Flange
www.dwyer-inst.com
•
MOUNTING
1 - Threaded
2 - Heavy Duty
Threaded
3 - Heavy Duty
Flanged
4 - Flanged
www.dwyer-inst.co.uk
LAG
0 - None
2 - 2˝
3 - 3˝
•
SHEATH O.D.
Base/Taper
1 - 5/8˝ / 1/2˝
4 - 3/4˝ / 1/2˝
6 - 7/8˝ / 1/2˝
7 - 7/8˝ / 5/8˝
8 - 1-1/16˝ / 5/8˝
9 - 7/8˝ / 49/64˝
A - 1-1/16˝ / 49/64˝
B - 5/8˝ straight
C - 49/64˝ straight
D - 7/8˝ straight
E - 3/4˝ straight
www.dwyer-inst.com.au
Extension Cables
"C" (4˝ STD)
"B"
Flexible extension cables are available with a variety of terminations.
Fill in the appropriate numbers or letters to specify the extension cable of your choice. Fill in all boxes. If an item or dimension
does not apply, fill those boxes with zeros ‘0’.
B
in feet
-
-
EC
SENSOR TYPE
EXTENSION TYPE
CALL TO ORDER:
-
C
Terminal #2
in inches
ELEMENTS
J (T/C)
K (T/C)
E (T/C)
T (T/C)
3 (3-Wire RTD)
0 - No Extension
1 - Fiberglass
Insulation
3 - Stainless Steel
Overbraid
4 - TFL Insulation
5 - Stainless Steel Flex
Hose
6 - TFL over SS Flex
Hose
C
Terminal #1
in inches
TERMINAL #1
TERMINAL #2
0 - Stripped Ends
1 - Lugs
2 - Lugs with BX
3 - Standard Plug
4 - Standard Jack
6 - Mini Plug
7 - Mini Jack
9 - Fastabs
A - Fastabs with BX
0 - Stripped Ends
1 - Lugs
2 - Lugs with BX
3 - Standard Plug
4 - Standard Jack
6 - Mini Plug
7 - Mini Jack
9 - Fastabs
A - Fastabs with BX
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
1 - Single
2 - Dual
•
Asia Pacific Phone 61 2 4272-2055
311
Temperature
Model Coding
Hand Held Thermocouples
T/C
Type
Model
J
K
1718-0076
1718-0077
J
K
1818-0073
1818-0074
J
K
1818-0077
1818-0078
J
K
1818-0081
1818-0082
J
K
1818-0084
1818-0085
J
K
1818-0088
1818-0089
J
K
1818-0092
1818-0093
J
K
1558-0030
1558-0013
General Purpose Probe - Featuring a built-in handle with coiled cord and
mini-plug, this general purpose probe can be used in liquids and air compatible gases. For use to 800°F.
J
K
1718-0001
1718-0002
High Temperature General Purpose Probe - Featuring a built-in handle with
coiled cord and mini-plug, this general purpose probe can be used in liquids
and air compatible gases. For use to 1600°F.
J
K
1718-0005
1718-0006
Penetration Probe - Featuring a built-in handle with coiled cord and miniplug, this probe is used for penetrating meat, plastic, rubber, asphalt, or other
semi-soft materials.
J
K
1718-0014
1718-0015
Straight Surface Probe - Featuring a built-in handle with coiled cord and miniplug, this probe is used for flat or semi-flat surfaces of metal, paper or plastic. Small gauge spring contoured tip allows fast response.
J
K
1718-0008
1718-0009
Angled Surface Probe - Featuring a built-in handle with coiled cord and miniplug, this probe is used for flat or semi-flat surfaces of metal, paper or
plastic. Small gauge spring contoured tip allows fast response.
J
K
1718-0011
1718-0012
Round Surface Probe - Featuring a built-in handle with coiled cord and miniplug, this probe measures temperature in ducts for rollers, convex surfaces.
Spring stainless steel replaceable band stretched across C-shaped bow.
J
K
1718-0022
1718-0023
J
K
1718-0018
1718-0019
Description
Master Probe Handle - Probes plug into the master probe handle. The
handle has a mini-jack at one end and a coiled cable with mini-plug on the
other. Individual probes may be connected to allow easy reach to your process.
Immersion Probe - This general purpose probe can be used in liquids and
gases. Includes mini plug.
Penetration Probe - Used for penetrating meat, plastic, rubber, asphalt, or
other semi-soft materials. Includes mini plug.
1/8" [3.18]
4"
[101.60]
Surface Probe - For flat or semi-flat surfaces of metal, paper or plastic. Small
gauge spring contoured tip allows fast response. Includes mini plug.
1/8" [3.18]
1/2"
[12.70]
8"
[203.20]
7/16" [11.11]
9/16" [14.29]
1/8" [3.18]
Air Duct Probe - Measures temperature in ducts for air or compatible gases,
environmental chambers, ovens, rooms, etc. Perforated shield has good air
flow and prevents heating by radiation. Includes mini plug.
Temperature
1/8"
[3.18]
8"
[203.20]
8"
[203.20]
Exposed Junction Probe - Small gauge tip allows high sensitivity and quick
response. The thermocouple junction is exposed for readings in air or
compatible gases. Includes mini plug.
1-5/8" [41.28]
1/16"
[1.59]
4"
[101.60]
Needle Probe - Small diameter penetrating probe gives fast response in
soft materials and liquids. Made with mineral insulated sheath for extra
durability. Includes mini plug.
1/16"
[1.59]
4"
101.60
Bare Tip Probe - This probe consists of 10 feet of 24 gauge wire with fiberglass braided cable and a bare wired junction. Shipped with a spool for easy
storage. Includes mini plug.
10"
[3048.00]
Integral Handle Probes - Featuring fixed handles and coiled cords, these rugged hand-held probes will plug into any device with a mini-jack.
Air Duct Probe - Featuring a built-in handle with coiled cord and mini-plug,
this probe measures temperature in ducts for air or compatible gases,
environmental chambers, ovens, rooms, etc. Perforated shield allows good air
flow and prevents heating by radiation.
312
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Plugs and Jacks
Standard Size Single Jacks (female)
Standard Size Single Plugs (male)
Type
J
K
T
Cu11
E
Cu
Cu
Conductors
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
3 (1 trio)
Type
J
K
T
Cu11
E
Cu
Cu
Part Number
481-0001
481-0002
481-0003
481-0004
481-0015
481-0022
481-0134
Part Number
481-0006
481-0007
481-0008
481-0009
481-0016
481-0023
481-0135
Miniature Size Single Jacks (female)
Miniature Size Single Plugs (male)
Type
J
K
T
R
S
E
Cu
Cu
Part Number
481-0093
481-0095
481-0094
481-0098
481-0097
481-0096
481-0099
481-0175
Conductors
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
3 (1 trio)
Part Number
481-0100
481-0102
481-0101
481-0105
481-0104
481-0103
481-0106
481-0174
Temperature
Type Conductors
J
2 (1 pair)
K
2 (1 pair)
T
2 (1 pair)
R
2 (1 pair)
S
2 (1 pair)
E
2 (1 pair)
Cu 2 (1 pair)
Cu
3 (1 trio)
Conductors
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
2 (1 pair)
3 (1 trio)
Pipe Adaptors
Part Number
1568-0007
1568-0008
1568-0009
1568-0011
1568-0012
1568-0013
1568-0020
1568-0021
Fits Pipe Diameters
1/2˝ to 7/8˝
7/8˝ to 1-1/2˝
1-5/16˝ to 2-1/4˝
2-1/4˝ to 3-5/16˝
3-5/8˝ to 4-1/4˝
4-5/16˝ to 5-1/4˝
6-1/4˝ to 6-3/4˝
7-3/4˝ to 8-1/4˝
Part Number
1568-0022
1568-0023
1568-0024
1568-0025
1568-0027
1568-0028
1568-0029
1-3/4˝ x 7/16˝ OD
Compression Fittings
Bayonet Adaptors
Type OD
1/8˝
1/8˝
3/16˝
3/16˝
1/4˝
1/4˝
.260 - .275˝
L
7/16˝
3/8˝
L
7/8˝
7/8˝
1-3/8˝
1-3/8˝
2-1/2˝
2-1/2˝
2-1/2˝
Fits Pipe Diameters
9-3/4˝ to 10-1/4˝
11-3/4˝ to 12-1/4˝
15-3/4˝ to 16-1/4
17-3/4˝ to 18-1/4˝
19-3/4˝ to 20-1/4˝
23-3/4˝ to 24-1/4˝
29-3/4˝ to 30-1/4˝
Thread Size
1/8-27 NPT
3/8-24 NPT
1/8-27 NPT
3/8-24 NPT
1/8-27 NPT
3/8-24 NPT
10 x 1.5 mm
CALL TO ORDER:
Part Number
1568-0001
1568-0002
1568-0003
1568-0004
1568-0005
1568-0006
1568-0016
U.S. Phone 219 879-8000
Thread Size
Material
1/8-27 NPT
Brass
1/8-27 NPT Stainless Steel
1/8-27 NPT
Brass
1/8-27 NPT Stainless Steel
1/4-18 NPT
Brass
1/8-27 NPT Stainless Steel
Teflon®
1/4-18 NPT
Part Number
144-0012
144-0020
144-0009
144-0022
144-0014
144-0024
144-0037
Transition Adaptor
These adaptors convert the minature plug on the end
of the coiled cable on the Master Probe Handle to a
standard lug. Simply plug the cord into the adaptor.
Catalog Number
Type K
Type J
Type T
481-127
481-126
481-128
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
1.5"
7/16"
313
Series
RTD
Resistance Temperature Detector
High Temperature, Mineral Insulated, 316 SS Sheath
.250 [6.35] OD
304 STAINLESS STEEL
POTTING ADAPTOR
.125 [3.175] OD
304 STAINLESS STEEL SHEATH
#8 SPADE TERMINAL
TYP 3 PLACES
FIBERGLASS INSULATED WIRE
WITH SEALED TIP
6.000
[152.4]
Temperature
MODELS
Length
Diameter
RTD-686
RTD-6812
RTD-6818
RTD-646
RTD-6412
RTD-6418
6˝ (15 cm)
12˝ (30.5 cm)
18˝ (46 cm)
6˝ (15 cm)
12˝ (30.5 cm)
18˝ (46 cm)
1/8˝
1/8˝
1/8˝
1/4˝
1/4˝
1/4˝
Series
GT
36.000
[914.4]
MARK WHITE
LEAD "+"
4.000
[101.6]
SPECIFICATIONS
Sensor Type: Wire wound, 100 ohm.
Temperature Range: -328 to 1202°F (-200 to 650°C).
Pressure Limits: 250 psig.
Probe Material: 316 SS.
Extension Length: 30˝ (76 cm).
Standard: DIN .00385 (Class B, 0.12%).
Precision RTD (Resistance Temperature Detector) offers excellent
accuracy and stability over a wide temperature range. Industry standard 3-wire 100 ohm (DIN) probes are available in 6˝ (15 cm), 12˝ (30.5
cm), or 18˝ (46 cm) sheath lengths with 30˝ (76 cm) extension cable and
spade lug terminals.
Model Number
MARK RED LEAD "-"
APPLICATIONS
Typical applications are: air ducts, bearing temperature, oil temperature indicator, soldering equipment, ovens, environmental test chambers, pharmaceutical mfg., food processing, plastic molding, petroleum
& chemical processing, electric generating plants, etc.
Spirit-Filled Glass Thermometers
Partial Immersion, ˚F and ˚C Ranges, Individually Serialized
Ø 0.250
[6.35]
(A)
Environmentally safe, Series GT Spirit-Filled Glass Thermometers
offer accurate and reliable temperature measurement without worry of
mercury contamination or disposal. Organically filled with blue or red
mineral spirits, these thermometers are designed for applications requiring only partial immersion. Individually serialized thermometers are calibrated over the entire scale and accurate to within NIST tolerances.
SPECIFICATIONS
Accuracy: ±1 scale division below 221°F (105°C), ±1.5 scale
divisions above 221°F (105°C) and ±2 scale divisions above
392°F (200°C).
Fill Solution: Blue fill contains Isoamyl Benzoate; Red fill may
contain Kerosene, Toluene, or Pentane with aniline dye.
Thermometer Length (A): 12˝ (305 mm) all models except for
GT500F and GT260C which are16˝ (405 mm).
Thermometer Diameter: 0.250˝ (6.35 mm).
Immersion Length: 3˝ (76 mm).
Weight: 0.1 lb (0.05 kg).
MODELS
Model
Number
GT120F
GT230F
GT300F
GT500F
GT110C
GT150C
GT200C
GT260C
GT5050C*
GT10050C*
Range
-30 to 120˚F
0 to 230˚F
0 to 300˚F
20 to 500˚F
-20 to 110˚C
-20 to 150˚C
-10 to 200˚C
-10 to 260˚C
-50 to 50˚C
-100 to 50˚C
Divisions
1°F
2°F
2°F
2°F
1°C
1°C
1°C
1°C
1°C
1°C
Length (mm)
12⬙ (305)
12⬙ (305)
12⬙ (305)
16⬙ (305)
12⬙ (305)
12⬙ (305)
12⬙ (305)
16⬙ (305)
12⬙ (305)
12⬙ (305)
Immersion
(mm)
3⬙ (76)
3⬙ (76)
3⬙ (76)
3⬙ (76)
3⬙ (76)
3⬙ (76)
3⬙ (76)
3⬙ (76)
3⬙ (76)
3⬙ (76)
APPLICATIONS
Manufacturing processes of petrochemicals, chemicals, food
and beverage products, waste water treatment, biotechnology,
and pharmaceutical industries. Use in ovens, water baths, incubators, and refrigeration.
*Uses red fill solution.
314
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Bimetal
Thermometers
2”, 3” or 5” Dial, Dual Scale, ±1% FS Accuracy, External Reset
Series
BT
Series BT Bimetal Thermometers offer accurate, reliable service even in
the toughest environments. These corrosion resistant units are constructed
from stainless steel and are hermetically sealed to prevent crystal fogging.
The bimetal element directly drives pointer, eliminating gears and linkage.
An external reset screw allows field calibration and easy-to-read aluminum
dial minimizes parallax error. Choose back connection, lower connection or
adjustable angle for easy viewing and installation. Adjustable models can be
rotated a full 360° and tilted over a 180° arc. NOTE: When using in pressurized applications, use a suitable thermowell.
SPECIFICATIONS
Wetted Materials: 304 SS.
Accuracy: ±1% full scale.
Response Time: )40 seconds.
Temperature Limits: Head: 200°F (93°C). Stem: Not to exceed 50% overrange or 1000°F (538°C) or 800°F (427°C) continuously.
Process Connection: 1/4˝ NPT on 2˝ dial size; 1/2˝ NPT on 3˝ or 5˝ dial
size.
Materials of Construction: 304 SS stem, glass crystal, anodized aluminum dial, Series 300 SS head, bezel, and mounting bushing.
Stem Diameter: 1/4˝ O.D.
Immersion Depth: Minimum 2˝ in liquids, 4˝ in gas.
Dial Size,
Stem Length
Degree
Div., °F(°C)
Temperature
Range, °F(°C)
Back Connection
BTB22551*
BTB2405D
BTB2409D
BTB32510D
BTB3255D
BTB3257D
BTB34010D
BTB3405D
BTB3407D
BTB3605D
2", 2-1⁄2"
2", 4"
2", 4"
3", 21⁄2"
3", 21⁄2"
3", 21⁄2"
3", 4"
3", 4"
3", 4"
3", 6"
0/250
0/250 (-20/120)
200/1000 (100/550)
0/200 (-20/100)
0/250 (20/120)
50/550 (10/290)
0/200 (-20/100)
0/250 (-20/120)
50/550 (10/290)
0/250 (-20/120)
Series
ST
2
2 (2)
10 (5)
2 (2)
2 (2)
5 (5)
2 (2)
2 (2)
5 (5)
2 (2)
Model
Dial Size,
Number
Stem Length
Adjustable Angle Connection
BTA54010D
BTA5405D
BTA5407D
BTA56010D
BTA5605D
BTA5607D
Temperature
Range, °F(°C)
Temperature
MODELS
Degree
Div., °F(°C)
5", 4"
5", 4"
5", 4"
5", 6"
5", 6"
5", 6"
0/200 (-20/100)
0/250 (-20/120)
50/550 (10/290)
0/200 (-20/100)
0/250 (-20/120)
50/550 (10/290)
2 (2)
2 (2)
5 (5)
2 (2)
2 (2)
5 (5)
3", 2.5"
0/250 (-20/120)
2 (2)
Lower Connection
BTC3255D
Surface Mount Thermometer
2” Dual Scale Dial, ±2% Full Scale Accuracy
2
[50.80]
1/2
[12.70]
BIMETAL SENSING ELEMENT
DWYER INSTRUMENTS, INC.
MICHIGAN CITY, IN. U.S.A.
MAGNETS
PROTECTIVE COVER &
HEAT COLLECTOR
Measure the temperature of boilers, air ducts, motors, bearings, furnaces or other surfaces with Series ST Surface Mount
Thermometers. Dual magnet design allows easy mounting on any
ferrous surface. Bi-metallic thermal sensing coil provides quick
temperature measurement with ±2% full scale accuracy.
MODELS
Range
ST250
ST500
ST750
0 to 250°F (-20 to 120°C)
0 to 500°F (-20 to 260°C)
0 to 750 °F (-20 to 399°C)
U.S. Phone 219 879-8000
Accuracy: ±2% full scale.
Sensing Element: Bimetal coil.
Response Time: Approximately
one minute.
Mounting: Two Alnico® magnets
on back.
Materials of Construction:
Aluminum with optically clear
crystal.
Head Size: 2˝ (5.08 cm).
Height: 1/2˝ (1.27 cm).
Weight: 2 oz (56.7 g).
APPLICATIONS
Model Number
CALL TO ORDER:
SPECIFICATIONS
R1-700423-00
•
Manifolds, platens, boilers, air ducts, furnaces, engines, motors,
bearings, enclosures, cabinets, drums, plumbing, piping, refrigerators, and other ferrous surfaces.
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
315
Temperature
Series
472
Digital
Thermocouple
Thermometer
Differential or Relative Temperature Readings, Stores Up to 25 Readings
SPECIFICATIONS
• High accuracy
temperature
measurement using
Type J and Type K
thermocouples.
• Measures in degrees
Fahrenheit or
degrees Celsius.
• Selectable resolution
for readings in degree
or in 0.1 degree
increments.
• Differential or relative
temperature
measurement using
the 6 mode.
• Stores and recalls up
to 25 temperature
measurements in either
normal or 6 mode.
Probe Types: Type J and K Thermocouples.
Probe Connection: ANSI female mini-connector.
Input Protection: 50V rms.
Temperature: Range: J: -350 to 2192°F (-210 to1200°C); K: -418 to
2500°F (-250 to 1372°C); Accuracy: 0.1% of reading ±0.7°F/0.4°C
(> -150°C); 0.1% of reading ±2°F/1°C (< -150°C); Resolution: 0.1°
(below 1999°).
Linearization: Conforms to NIST monograph 175 revised to ITS-90.
Operating Conditions: Stated accuracy: 64 to 82°F (18 to 28°C).
Operating Ambient Temperature: 14 to 104°F (-10 to 40°C). Storage
Temperature: -40 to 176°F (-40 to 80°C).
Display: Dual 42 digit LCD.
Battery: 9 Volt alkaline.
Battery Life: 200 Hours (typical).
Memory: 25 Samples (Normal or DT mode).
Housing Size: 6 ⁄ ˝ H ⫻ 2 ⁄ ˝ W ⫻ ⁄ ˝ D (166 ⫻ 71 ⫻ 23 mm).
9
The Series 472 Digital Thermocouple Thermometer is a
precision general purpose thermometer designed for use with
Type J or Type K thermocouples that can be field calibrated. A
standard ANSI thermocouple connector allows the use of a wide
variety of probe styles. The unit records and displays minimum
and maximum temperature readings and has a 20 minute auto
power off to conserve the battery. The 42 digit LCD is backlit for
dark or low light conditions.
16
29
32
L-402-A CARRYING CASE — Tough gray nylon
pouch protects any Series 472 Thermometer.
Double zippered for quick and easy access. With
belt loop that snaps closed.
72"h x 3"w x 24"d
(191 x 76 x 57 mm)
Model 472 Digital Thermocouple Thermometer
Series
472 Kits
13
16
Digital
Thermocouple
Thermometer
Kits
Accepts Type J or K Thermocouples
Complete kits include:
•
•
•
•
Master probe handle.
Surface, Air Duct, Immersion and Bare Tip Probes.
9V battery.
High accuracy Series 472 Digital Thermocouple Thermometer
that measures temperature using Type J or Type K
thermocouples.
Features of the Series 472 unit include:
• Measurement in °F or °C.
• Selectable resolution for readings in degree or in 0.1 degree
increments.
• Differential or relative temperature measurement using the
6 mode.
• Stores and recalls up to 25 temperature measurements in
either normal or 6 mode.
Model 472-2 Kit with Type K Thermocouple
Model 472-3 Kit with Type J Thermocouple
316
VISIT OUR WEBSITES:
www.dwyer-inst.com
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Model
TC10
Digital Thermocouple Thermometer
Type K Thermocouple, Large 3 1/2⬙ Digit Display, ±0.3% Accuracy
7-1/2
[190.50]
3-1/2
[88.90]
Model TC10 Digital Thermocouple Thermometer
Model TC10-N includes NIST certification
Model
TC20
SPECIFICATIONS
Input: Type K (4’ type K thermocouple bead probe included).
Temperature Range:
-58 to 2000˚F (-50 to 1300˚C).
Accuracy: -58 to 2000˚F:
±(0.3% of reading + 2˚F); -50 to
1000˚C: ±(0.3% of reading +
1˚C); 1000 to 1300˚C: ±(0.5% of
reading + 1˚C).
Display: 0.8˝ (20 mm) height, 3
1/2 digit LCD with switchable
back light.
Resolution: Selectable 1˚ or
0.1˚.
Response Time: 1 second.
Temperature Limits:
32 to 122˚F (0 to 50˚C) max 80%
RH.
Storage Temperature: -4 to
140˚F (-20 to 60˚C) max 70%
RH.
Power Requirements:
Standard 9V battery (included).
Battery Life: 200 hours typical.
Input Protection: 24V rms.
Thermocouple Connection:
Standard (F) mini-connector.
Housing: ABS plastic.
Weight: 12.9 oz (365 g).
Agency Approvals: CE.
Dual Input ThermocoupleThermometer
Accepts Type J or K, High/Low Alarm, Selectable Resolution
7.600
[193.04]
3.600
[91.44]
Quickly measure differential temperatures with Model TC20
Dual Input Thermocouple Thermometer. Model TC20 accepts type J
or K thermocouples and simultaneously displays T1, T2, or T1-T2 and
elapsed time on a large, multi-function LCD. The unit features programmable high/low audible alarms, max/min, average readings, display hold and relative mode. The relative mode permits the user to
store the current temperature value and compare it to subsequent
temperature readings. Model TC20 thermometer includes two type K
bead wire probes, rubber holster, 9V battery and instruction manual.
Model TC20 Dual Input Thermocouple Thermometer
Model TC20-N Includes NIST Certification
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Input: Type J or K [Two 4 ft (100
m) type K thermocouple bead
probes included].
Temperature Range: -328 to
1922°F (-200 to 1050°C) For type
J;-328 to 2498°F (-200 to 1370°C)
for type K.
Accuracy: -58 to 2498°F (-50 to
1370°C): ±0.05% of reading +
0.6°F (0.3°C) -328 to -58°F (-200
to -50°C): ±0.05% of reading +
1.4°F (0.7°C).
Display: 0.8˝ (20 mm) height, 5digit LCD with switchable back
light.
U.K. Phone (+44) (0)1494-461707
•
2.100
[53.34]
Resolution: Selectable 1° or 0.1°.
Response Time: 1 second.
Temperature Limits: 32 to 122°F
(0 to 50°C) max 80% RH.
Storage Temperature: -4 to
140°F (-20 to 60°C) max 70% RH.
Power Requirements: 9V
Alkaline (included).
Battery Life: 200 hours typical.
Thermocouple Connection:
Standard female mini-connector.
Housing: ABS Plastic.
Weight: 13 oz (365 g).
Agency Approvals: CE.
Asia Pacific Phone 61 2 4272-2055
317
Temperature
Quickly and accurately measure temperature with the Model
TC10 Digital Thermocouple Thermometer. The TC10 accepts any type
K thermocouple and connects via a standard mini-connection. View
temperature readings in °F or °C (field selectable) on the large 32
digit LCD. The 0.8⬙ (20 mm) display is backlit for dark or low light conditions. Choose either 0.1° or 1° resolution each with the basic accuracy of 0.3%. Thermometers respond quickly to environmental changes
by updating the readings 2.5 times every second. Rugged, water resistant design comes with a protective holster and stand—ideal for field
use. Additional features include low battery indication, MAX and
HOLD functions. Units include protective holster, Type K thermocouple bead wire temperature probe, 9V battery and instruction manual.
2-1/32
[51.58]
Series
IR
Infrared Temperature Thermometer
SPOT DIA. (INCHES)
Laser Sighting, Adjustable Emissivity, Datalogger
8.75
[222]
Temperature
12
1.5
36
60
5.3
3
D:S = 12:1
SPOT DIA. (CM)
2.00
[51]
DISTANCE: SENSOR TO OBJECT (INCHES)
5.63
[143]
3.8
30
7.5
90
DISTANCE: SENSOR TO OBJECT (CM)
SPECIFICATIONS
Take fast, easy and safe temperature measurements with
the Series IR Infrared Thermometers. The IR450-1 offers single point laser sighting and a fixed emissivity at 0.95 to accurately measure concrete, asphalt, rubber and oxidized metals.
Models IR600-1 and IR700-1 combine advanced infrared technology with powerful optics to take noncontact temperature measurements of the most demanding applications.
Accuracy: ±1% or ±2˚F (±1˚C) whichever is greater.
Emissivity: 0.95 fixed or adjustable.
Distance-to-Target Size Ratio: See table.
Laser Classification Single Point: 1 mW, meets FDA Class II
requirements.
Display: 4-Digit.
Resolution: 0.5˚F (0.2˚C).
Response Time: 500 ms.
Ambient Operating Temp: 32 to 150˚F (0 to 50˚C), 10-95% RH.
Power Requirements: One 9V alkaline battery or NiCad Battery.
Average Battery Life: Approximately 10 hrs with laser and backlight on.
Repeatability: ±0.5% of reading or ±2˚F (±1˚C) whichever is
greater.
Spectral Response: 8 to 14µm.
Weight: 11 oz (320 g).
Agency Approvals: CE.
Model IR600-1 offer a 30:1 distance to target ratio while Model
IR700-1 offers a ratio of 50:1. The 4-digit backlit LCD displays
the current temperature readings as well as the minimum, maximum, differential as average temperatures. Both models feature a unique bright single point laser sighting, and 12-point datalogging capability. All Series IR offer selectable °F or °C and
include a hard carry case.
MODELS
318
Model
Number
Temperature
Range
Distance-to
Target Ratio
Emissivity
IR450
-25 to 950°F
(-32 to 545°C)
12:1
Fixed
IR600-1
-25 to 1100°F
(-32 to 600°C)
30:1
Adj.
IR700-1
-25 to 1400°F
(-32 to 760°C)
50:1
Adj.
VISIT OUR WEBSITES:
www.dwyer-inst.com
13.2
150
ACCESSORIES
Model IR8C Protective Plastic Hardcase
Model IR8SC Nylon Soft Case with integral belt loop
* NIST certified models add suffix N to model number
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
IRE
Infrared Thermometer Expanded
Laser Sighting, ±1% Accuracy, Numeric and Graphical Display
1.938
[49]
DISTANCE: SENSOR TO OBJECT (INCHES)
SPOT DIA. (CM)
5.039
[128]
3.169
[80.5]
7.750
[197]
MODELS
Model
Number
Description
IRE50-1*
Adjustable emissivity, MIN, MAX,
Hi alarm, and bar graph
Adjustable emissivity, MIN, MAX, DIF, AVG,
Hi/Lo alarm, t/c input, RS232, graph and tables
(includes software, cables, Type K probe)
Same as IRE61 and Integral Digital
Photography Function
Model
MIR1
0.7 0.8
96
1.7
120
2.3
SPOT DIA. (CM)
1.188
[30]
1.8
2
61
91
4.3
183
5.8
305
DISTANCE: SENSOR TO OBJECT (CM)
SPECIFICATIONS
Temperature Range: –25 to 1600°F (–32 to 900°C), selectable.
Accuracy: ±1% of reading or ±1.5°F (±1°C), whichever is greater.
Emissivity: Adjustable from 0.1 to 1.0.
Distance-to-Target Size Ratio: 60:1, nominal.
Laser Classification: 1 mW, meets FDA Class II requirements.
Display: 4-digit.
Resolution: 0.1°F or °C.
Response Time: 250 msec.
Power Requirements: Two AA alkaline batteries (included).
Repeatability: ±0.5% of reading or ±1°F (±1°C), whichever is greater.
Thermocouple Input: Type K or J (model IRE61-1 & IRE90 only).
Output: RS232 (model IRE61-1 & IRE90 only).
Computer Requirements: (For models IRE61-1 & IRE90 only): This
product works with Windows® 98, Windows® 2000 or Windows® XP and
one USB port.
Weight: 1.6 lb (480 g).
Agency Approvals: CE.
Accessories
No. IRE7, padded pouch and belt clip
*For a NIST certified unit add suffix N to model number.
Mini Infrared Thermometer
Laser Sighting, Measure Temperatures Up To 600°F (315°C)
6.33
[161]
1.56
[40]
Low cost, noncontact Model MIR1 Mini Infrared Thermometer
is ideal for measuring the temperature of an object at a safe distance.
Use the MIR1 to detect heat problems in equipment, machinery, or
processes. Equipped with laser sighting to accurately pinpoint targets. The MIR1 features a 6:1 distance-to-target ratio, fixed emissivity, selectable °F or °C, display hold, and an LCD backlight.
Model MIR1 Mini Infrared Thermometer
ACCESSORIES
Model IR8SC Soft case with wrist strap
CALL TO ORDER:
U.S. Phone 219 879-8000
•
4.50
[114]
2.50
[63.5]
SPECIFICATIONS
Temperature Range: 0 to 600°F (-20 to 315°C).
Accuracy: ±2% of reading or ±4°F (±2°C) whichever is greater.
Emissivity: Fixed at 0.95.
Distance-to-Target Size Ratio: 6:1, nominal.
Laser Classification: Single Point.
Display: 3-Digit, 3/8˝ height.
Resolution: 1°C/°F.
Response Time: 0.5 seconds.
Ambient Operating Temperature: 32 to 122°F (0 to 50°C),
80% RH max.
Power Requirements: One 9V alkaline (included).
Power Current: 12 mA DC, approximate.
Sample Rate: 1 second, approximate.
Weight: 6.4 oz (200 g).
Agency Approvals: CE.
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
319
Temperature
Series IRE Infrared noncontact thermometer features a unique 3point laser sighting with center aiming point that defines the area being
measured. All models have a selectable °F or °C, adjustable emissivity,
MIN and MAX temperature, audible and visible high alarm, and a bar
graph display indicating the last tem measurements. Model IRE61-1 and
IRE90 also features average and differential temperatures, thermocouple input, RS232 output, low alarm, and on-board emissivity tables for 30
preset materials. Use the data management software included with model
IRE-61-1/IRE90 for graphing and analysis of temperature measurements.
Model IRE90 also features an integral digital camera to simultaneously
measure temperature and digitally photograph the measured area. Units
include hard carrying case and instruction manual.
IRE90
46
D:S = 60:1
6.563
[167]
IRE61-1*
36
Model
PIR1
Pocket-Size Infrared Thermometer
Adjustable Emissivity, Laser Targeting, Selectable °F or °C
6.086
[154.58]
2.071
[52.60]
Temperature
1.300
[33.02]
SPECIFICATIONS
The PIR1 Pocket-Size Infrared Thermometer allows for temperature measurement of processes not suited for conventional
“contact” measurements. Model PIR1 will display real time, maximum, minimum, differential or average temperature readings
with a push of a button. The large, 3-digit LCD is backlit to allow
for use in low light areas. Additional features include an audible
high/low alarm, laser targeting, adjustable emissivity and selectable °F/°C measurements. Vinyl carrying case, lanyard, 9V battery and instructions are included.
Temperature Range: 0 to 600°F (-20 to 315°C).
Accuracy: ±2% of reading or ±4°F (±2°C) whichever is greater.
Emissivity: Adjustable 0.3-1.0.
Distance-to-Target Size Ratio: 6:1, nominal.
Laser Classification Single Point: Class II (Output <1mW).
Display: 3-Digit, 1/4˝ height. Automatically shuts off 7 seconds
after hold button is released.
Resolution: 1°C/°F.
Response Time: 500 ms.
Ambient Operating Temperature: 32 to 122°F (0 to 50°C),
80% RH max.
Power Requirements: One 9V alkaline battery (included).
Sample Rate: 0.5 seconds minimum.
Weight: 6.3 oz (180 g).
Agency Approvals: CE.
Model PIR1 Pocket Size Infrared Thermometer
Model
IRM20
Noncontact
Infrared
Thermometer
6:1 Distance-to-Target Size Ratio, Selectable °F or °C, Laser Sighting
7-1/4
[184.15]
1-5/8
[41.28]
SPECIFICATIONS
The economical, handheld Model IRM20 Noncontact Infrared Thermometer is compact, rugged and easy to use—just aim, push the button,
and read current surface temperatures in less than a second. Hot, hazardous, or hard-to-reach objects are safely measured without contact.
The unit has a wide temperature range from 0 to 500°F (-18 to 260°C) and
a distance-to-spot size ratio of 6:1. The LCD shows temperatures in
switchable °F or °C, holds the reading for 7 seconds after the button is
released and indicates when the battery is low. The IRM20 is ideal for industrial, electrical, heating and air conditioning, automotive and food
safety.
Temperature Range: 0 to 500°F (-18 to 260°C).
Accuracy: ±2% of reading or ±3.5°F (±2°C) whichever is greater for targets at
30 to 500°F (-1 to 260°C); ±5°F (±3°C) for targets at 0 to 30°F (-18 to -1°C).
Emissivity: Fixed 0.95.
Distance-to-Target Size Ratio: 6:1.
Laser Classification: Single Point.
Display: 4-digit.
Resolution: 1°F/°C.
Response Time: 500 ms, 95% response.
Ambient Operating Temperature: 32 to 120°F (0 to 50°C).
Power Requirement: One 9V battery (included).
Battery Life: 12 hours.
Repeatability: ±2% of reading or ±3°F (±2°C).
Storage Temperature: -4 to 150°F (-20 to 65°C) without battery.
Relative Humidity: 10-95% RH noncondensing up to 86°F (35°C).
Spectral Response: 7-18 µm.
Weight: 0.5 lb (227 g).
Agency Approvals: CE.
Model IRM20 Noncontact Infrared Thermometer
320
VISIT OUR WEBSITES:
www.dwyer-inst.com
1-1/2
[38.10]
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Model
WT-10
Waterproof Thermometer
Stainless Steel Stem, Selectable °F or °C, Max/Min Recall, Auto Off
13/16
[20.32]
WT-10
45/64
[17.78]
5-57/64
[149.86]
SPECIFICATIONS
Temperature Range: -40 to 392°F (-40 to 200°C).
Accuracy: ±2°F (±1°C) from –14 to 212°F (–26° to 100°C); all
other temperature ranges ±3°F (±2°C).
Display: 3-digit LCD.
Resolution: 0.1°F/°C.
Response Time: 1 second.
Power Requirements: One 1.5V button style battery (included).
Battery Life: Approximately 1 year.
Construction: 2.75˝ (70 mm) stainless steel pointed stem and
ABS waterproof housing.
Weight: 0.7 oz (20 g).
Agency Approvals: CE.
Model WT-10 Waterproof Thermometer
Series
MIL
Mini In-Line IR Sensor
Temperature Measurement System, Adjustable Emissivity, Field Selectable Outputs
M12 ⫻ 1
2.400
[60.96]
.430
[10.92]
1.100
[27.94]
3.200
[81.28]
Series MIL Mini In-Line IR Sensor is a complete temperature measurement system. The unit includes a miniature sensing head and remote
electronics for easy installation. The remote electronics include selectable output, LCD display, head temperature signal, adjustable emissivity, and peak/valley/averaging. The sensor is housed in a rugged
NEMA 4 (IP65) stainless steel enclosure and is connected to the electronics via a 9.8 ft (3 m) cable. Includes 1 mounting nut.
MODELS
Model Number
MIL2C*
MIL5C*
Distance-to-Target Size Ratio
2:1
10:1
*For optional RS232 communication, add “R” suffix to part number
ACCESSORIES
Model XXXMIACMN Replacement Mounting nuts (2 pieces)
Model XXXMIACFB Fixed Mounting Bracket
Model XXXMIACAB Adjustable Mounting Bracket
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Temperature Range: -40 to
1112˚F (-40 to 600˚C) for mA, V or
K thermocouple output: -13 to
1112˚F (-25 to 600˚C) for J thermocouple output.
Accuracy: mA or V output: ±1%
of reading or ±1˚C whichever is
greater. T/C output: ±1% or ±2.5˚C
whichever is greater.
Emissivity: 0.100 to 1.100 digitally
adjustable increments of .001.
Distance-to-Target Size Ratio:
2:1 or 10:1.
Resolution: 0.5˚F (0.3˚C).
Response Time: 150 ms (95%).
Ambient Operating Temp:
Sensing head: 32 to 185˚F (0 to
85˚C); Electronics: 32 to 150˚F
(0 to 65˚C).
U.K. Phone (+44) (0)1494-461707
•
1.000
[25.40]
Power Requirement: 11-26 VDC.
Repeatability: ±0.5% of reading
or ±1˚F (±0.5˚C) whichever is
greater.
Storage Temperature: 0 to 185˚F
(-18 to 85˚C).
Outputs: Scalable 4-20 mA, 0-20
mA, 0-5 V, J or K thermocouple.
Cable Length: 9.8 ft (3 m).
Spectral Response: 8 to 14 µm.
Housing: NEMA 4 (IP65), Sensing
head: stainless steel; Electronics:
Die-cast zinc.
Weight: Sensing head: 1.75 oz
(50 g); Electronics: 9.5 oz
(270 g).
Agency Approvals: CE.
Asia Pacific Phone 61 2 4272-2055
321
Temperature
Completely submersible, the pocket size Model WT-10
Waterproof Thermometer is designed with a waterproof housing and a 2.75˝ (70 mm) stainless steel stem. The unit offers
dual scale temperature measurements up to 392°F (200°C) on
the 3-digit LCD display. The WT-10 comes complete with protective cover to store the unit while not in use. The features
include MAX/MIN recall of high and low temperatures, hold,
switchable °F or °C and auto shut off. Ideal applications include
laboratory, food and beverage, HVAC and scientific markets.
In-Line IR Sensor
Series
IL
4:1 Distance-to-Target Ratio, NEMA 4 (IP65), 32 to 662˚F (0 to 350˚C)
3/4-16 UNF 2A
Ø.560
[14.22]
Ø.670
[17.02]
.750
[19.05]
.270
[6.86]
3.500
[88.90]
SPECIFICATIONS
Replace traditional contact temperature probes with Series IL In-Line
IR Sensors. These compact, low cost sensors utilize infrared technology to take non-contact temperature readings between 32 and 662°F (0
to 350°C). The onboard electronics are protected by a rugged NEMA4
(IP65) stainless steel housing. Select between a J-Type thermocouple or
a 0-5 volt linear output for connection to a controller, display or transmitter. Includes 2 mounting nuts.
Temperature Range: 32 to
662˚F (0 to 350˚C).
Accuracy: ±2% of reading or
±6˚F (±3˚C) whichever is greater
for 32 to 240˚F (0 to 115˚C);
±5% of reading or ±10˚F (±6˚C)
whichever is greater for 241 to
440˚F (116 to 225˚C); >±5% of
reading for 441 to 662˚F (226
to 350˚C).
Emissivity: 0.95 fixed.
Distance-to-Target Size
Ratio: 4:1.
Resolution: 1˚F (0.5˚C).
Response Time: 350 ms.
Ambient Operating Temp:
32 to 160˚F (0 to 70˚C).
Temperature
MODELS
Model Number
IL10
IL30
Output
J Thermocouple
0-5V
ACCESSORIES
Model XXXCIACMN Mounting nuts (2 pieces)
Model XXXCIACFB Fixed Mounting Bracket
Model XXXCIADJB Adjustable Mounting Bracket
Model XXXCIDCPS 24VDC Power Supply
Series
IM/IMS
Power Requirements: 12-24
VDC.
Repeatability: ±1% of reading
or ±2˚F (±1˚C) whichever is
greater.
Storage Temperature:
-22 to 185˚F (-30 to 85˚C).
Outputs: J-thermocouple or
0-5 volt.
Cable Length: 3 ft (0.9 m).
Spectral Response: 7 to 18
microns.
Housing: NEMA 4 (IP65),
stainless steel.
Weight: 4.5 oz (130 g).
Agency Approval: CE.
IR Monitoring System
0 to 1000˚F (-18 to 538˚C), 1/8 DIN Digital Monitor, Dual Alarm Setpoints
1.900 [48.26]
4.130
[104.90]
3.780
[96.01]
1-1/2 20UN-2A
Ø.500
[12.70]
Ø1.650
[41.91]
.230
[5.84]
Combine a Series IM Panel Meter with a Series IMS IR Sensor to create a
complete infrared temperature monitoring system. Series IM 1/8 DIN panel
meters display the temperature in °C or °F on a large 4-digit LED. These
meters provide advanced infrared processing capabilities such as peak and valley hold, averaging, and a user-adjustable offset. In addition, each monitor provides a user-defined 4-20 mA or thermocouple output as well as adjustable dual
setpoints and deadband alarm outputs.
The Series IMS IR Sensors are available with standard or close-focus optics and
provide target temperature readings with a ±1% accuracy. Model IMS1 has a
35:1 distance-to-target ratio and are ideal for taking the temperatures of objects
up to 35 inches away. The 3:0.1 distance-to-target ratio of Model IMS2 allows
the sensor to monitor temperatures of objects as small as 0.1 inch at 3 inches
away.
SPECIFICATIONS
Temperature Range: 0 to 1000˚F
(-18 to 538˚C).
Accuracy: ±1% of reading or ±2˚F
(±1˚C) whichever is greater.
Emissivity: 0.1 to 1.09 digitally
adjustable increments of .01.
Distance-to-Target Size Ratio:
IMS1: 35:1; IMS2: 3:0.1.
Display: 4-digit, 7-segment LED
display.
Resolution: 0.5˚F (0.3˚C).
Response Time: 500 mS (95%).
Ambient Operating Temp:
Sensing head: 32 to 150˚F
(0 to 65˚C); Monitor: 32 to 120˚F
(0 to 50˚C).
MODELS
Model IM1 1/8 DIN Panel Meter
Model IM2 1/8 DIN Panel Meter with relays
Model IMS1* Infrared Sensor, 35:1 (cable sold seperately)
Model IMS2* Infrared Sensor, 3:0.1 (close focus optics)
(cable sold seperately)
Model IMS-L* Infrared sensor with laser sighting and cable, 50:1
VISIT OUR WEBSITES:
www.dwyer-inst.com
1.180
[29.97]
Power Requirements: 110/220
VAC.
Repeatability: ±0.5% of reading
or ±2˚F (±1˚C) whichever is greater.
Storage Temperature: -22 to
150˚F (-30 to 65˚C).
Outputs: User configurable 4-20
mA or thermocouple output (J, K,
E, N, R, S, T).
Alarm Outputs: IM1: 5 VDC; IM2:
3A @ 24 VDC SPDT relays.
Spectral Response: 8 to 14 µm.
Housing: Sensor: NEMA 4 (IP65);
Meter front panel: NEMA 12.
Weight: Sensor: 0.7 lb (320 g);
Meter: 1 lb (454 g).
Agency Approvals: CE.
ACCESSORIES
Model XXXTXXACFB Fixed Mounting Bracket (Included)
Model XXXTXXACAB Adjustable Mounting Bracket
Model XXXGPRCB8 26 ft (8 m) Conductor Cable (Not Included)
* For water cooled housing add “W” suffix to part number
322
4.920
[124.97]
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Series
LCT016
Analog Timers
Low Cost, 1/16 DIN Panel Mount, Four Timing Functions
48.0
(1.89)
16.0
(0.630)
48.0
1.890)
63.7
(2.062)
44.8
(1.764)
37.0
(1.46)
80.4
(3.165) 94.0
(3.701)
Dimensions in mm (inches)
The LCT016 Analog Timers provide simple, yet economical solutions
for a variety of timing applications. Installation is simple with compact
1/16 DIN package. Scale and timing functions are easily adjusted with
individual front mounted switches. The included tamper resistant cover
discourages unauthorized changes of the scale, timing functions and
restricts movement of the analog set point knob. Two LEDs on the front
indicate power and output status. Four different timing functions and
sixteen different time scales give you the greatest flexibility.
Series
LCT116
SPECIFICATIONS
Operating Temperature Range:
32 to 131°F (0 to 55°C).
Humidity Conditions: 35 to 85%
RH, non-condensing.
Control Output Ratings: Relay,
SPDT, 5A @ 250 VAC resistive.
Weight: 3.17 oz (90 g).
Socket: LCT016-3x: Standard 8pin plug-in socket. LCT016-1x:
Standard 11-pin plug-in socket.
Accuracy: Repeatability: ±0.3%
of maximum rated time. ±0.3%
±10ms for 1.2 sec range. Line
Stability: ±0.5% of maximum rated
time, ±0.5% 10ms for 1.2 second
range.
Reset Time: 0.1 second, maximum.
Status Lights: Green LED indicates power on. Red LED indicates
output status.
Inputs: Logic inputs for Start,
Reset, and Inhibit. Timing functions: a. Signal On - Delay; b.
Flicker OFF Start; d. Signal ON/Off
Delay; e. Signal OFF delay.
Supply Voltage: 100 to 240
VDC/VAC 50~60 Hz.
Power Consumption: 10VA.
Digital Timers
Low Cost, 1/16 DIN Panel Mount,Ten Timing Functions
48.0
(1.89)
16.0
(0.630)
48.0
(1.890)
MODELS
LCT116-10 8-pin timer
LCT116-20 11-pin timer
481-0153 (8-pin sockets)
481-0164 (11-pin sockets)
CALL TO ORDER:
U.S. Phone 219 879-8000
•
SPECIFICATIONS
Operating Temperature Range:
32 to 131°F (0 to 55°C).
Humidity Conditions: 35 to 85%
RH, non-condensing.
Control Output Ratings: Relay,
SPDT, 5A @ 250 VAC resistive.
Weight: 5.3 oz (150 g).
Socket: LCT116-1x: Standard
8-pin plug-in socket. LCT116-2x:
Standard 11-pin plug-in socket.
Accuracy: Repeatability: ±0.3%
of maximum rated time.
Line Stability: ±0.5% of maximum
rated time.
Status Light: LCD shows time
and function details.
U.K. Phone (+44) (0)1494-461707
•
13.6
(0.535)
44
(1.7
37.0
(1.46)
Dimensions in mm (inches)
The LCT116 Digital Timers provide simple, yet economical solutions for a variety of timing applications. Installation is simple with
compact 1/16 DIN package. Set point and timing functions are easily
adjusted with the individual set buttons. A LCD display on the front
indicates current time status and a bargraph for indicating relative
time remaining. Ten different timing functions and ten different time
scales give you the greatest flexibility.
63.7
(2.062)
80.4
(3.165) 94.0
(3.701)
Inputs: Logic inputs for Start,
Reset, and Inhibit.
Timing functions:
a. Signal On - Delay; b. Flicker on
Start; c. Signal ON/Off Delay; d.
Signal OFF Delay; e. Interval Mode;
f. One Shot and Flicker; g.
Integration Time; h. Interval Delay;
i. Flicker - One Shot; j. Power On
Start.
Supply Voltage: 100 to 240
VDC/VAC 50~60 Hz.
Power Consumption: 10 VA.
Asia Pacific Phone 61 2 4272-2055
323
Temperature
MODELS
LCT016-10 11-pin timer
LCT016-30 8-pin timer
481-0153 (8-pin sockets)
481-0164 (11-pin sockets)
13.6
(0.535)
Series
LTT
SSR Monitors
Monitors SSRs for Loss of Line, Open Load, Shorted SSR, Loss of DC Power
FEATURES
• Monitors SSRs for loss of line, open load, shorted SSR, loss of DC Power
• Mounts on standard SSRs over the Connection Terminals
• Designed to fit under finger safe cover
• LED Status Indicator
• Normally Closed dry relay contact 200VDC @ 0.5A max.
MODELS
Temperature
Model
Number
LTT12-0
LTT24-0
Love Controls LTT Series SSR Monitors allow easy monitoring of the operation of your SSR switches. This handy device compares the input status with the
output status. An alarm operates a relay contact to tell you if the load circuit has
opened or if the SSR has shorted. The LTT mounts easily on most SSRs with no
additional hardware. Protect your system today.
Series
LTTJ
Description
Solid State Relay Monitor, 10-19 VDC Trigger,
100-660 VAC Load
Solid State Relay Monitor, 20-32 VDC Trigger,
100-660 VAC Load
Solid State Relay Monitor, 10-19 VDC Trigger,
100-660 VAC Load w/Driver Circuit Test
Solid State Relay Monitor, 20-32 VDC Trigger,
100-660 VAC Load w/Driver Circuit Test
LTT12-1
LTT24-1
Current Transformers
0 to 10 VDC Analog Output, Fully Adjustable Output, Over Voltage Protection
MODELS
Model
Number
LTTJ-010
LTTJ-020
LTTJ-030
LTTJ-040
LTTJ-050
LTTJ-060
LTTJ-070
LTTJ-080
LTTJ-090
LTTJ-100
LTTJ-103
Love Controls LTTJ Series Current Transformers allow easy monitoring of
the current flowing to your load. This easy to use device provides a 0 to 10 VDC
signal into both low and high impedance circuits, and is easily scalable to your
needs.
Available in a number of different ranges, the LTTJ Series can be easily mounted
on most LTP Series Solid State Relays for convenient wiring. Some models feature an LED for visual confirmation that current is flowing through the device.
VISIT OUR WEBSITES:
www.dwyer-inst.com
Current Transformer Calibrated to 10 VDC at 20 Amps
Current Transformer Calibrated to 10 VDC at 30 Amps
Current Transformer Calibrated to 10 VDC at 40 Amps
Current Transformer Calibrated to 10 VDC at 50 Amps
Current Transformer Calibrated to 10 VDC at 60 Amps
Current Transformer Calibrated to 10 VDC at 70 Amps
Current Transformer Calibrated to 10 VDC at 80 Amps
Current Transformer Calibrated to 10 VDC at 90 Amps
Current Transformer Calibrated to 10 VDC at 100 Amps
Current Transformer Adjustable from 10 to 30
Amps, 5-10 VDC Output
LTTJ-305 Current Transformer Adjustable from 30 to 50
Amps, 5-10 VDC Output
Current Transformer Adjustable from 10 to 30
LTTJ-103I
Amps, LED Output
Current Transformer Adjustable from 30 to 50
LTTJ-305I
Amps, LED Output
Current Transformer Adjustable from 10 to 30
LTTJ-103S Amps, NPN Transistor Output
Current Transformer Adjustable from 30 to 50
LTTJ-305S Amps, NPN Transistor Output
FEATURES
• 0 to 10 VDC Analog Output
• Impedance Matching for High or Low Impedance Inputs
• Fully Adjustable Output
• Over Voltage Protection
324
Description
Current Transformer Calibrated to 10 VDC at 10 Amps
•
www.dwyer-inst.co.uk
•
www.dwyer-inst.com.au
Technical Reference Books
Plant Engineer’s Handbook
Edited by R. Keith Mobley, 2001
• Produced in association with Plant Engineering Magazine and created by
leading authors and editor
• International perspective with dual units and regulations
Offers comprehensive coverage of an enormous range of subjects, which are of vital interest to the
plant engineer and anyone connected with industrial operations or maintenance. Includes plant site
selection, basic facilities, lubrication, corrosion, energy conservation, maintenance, insurance matters, materials handling, financial concerns, and environmental considerations.
Order Number: BK-0003
ISBN: 0750673281, Pages: 2400, Hardback
Instrumentation Reference Book
Third Edition
Edited by Walt Boyes, 2002
This reference book is a comprehensive and authoritative collection of technical information, which
is of direct value to instrumentation and control engineers as well as instrumentation technicians and
users. Covers topics such as measurement of flow, viscosity, length, strain, level, volume, vibration,
force, density, pressure, radiation, particle size, temperature, noise, optical, and chemical composition. Also includes instrumentation systems and technical references.
Order Number: BK-0002
ISBN: 0750671238, Pages: 1062, Hardback
Guide to the 2005 National Electrical Code
By Paul Rosenberg, 2004
•Understand the terms and rules for installation set forth in the NEC
•Review each section of the NEC that applies to electrical installation
•Learn about the significant changes in bonding and grounding requirements
•Explore the expanded section covering communications equipment
This guide extracts the necessary information for installers and arranges it for easy access, highlighting the changes so you can quickly spot what’s new. If you’re a novice or even a veteran, you’ll
want this book with you on every job.
Order Number: BK-0012
ISBN: 0764578022, Pages: 816, Paperback
Electrician’s Pocket Manual
Second Edition
By Paul Rosenberg, 2003
• Explains updated maintenance and construction standards
• Provides details on motors, controllers, and circuits
• Examines electronic components and communications wiring
• Offers guidelines for dealing with hazardous location wiring
• Covers generators, mechanical power transmission, and electrical power distribution
The Electrician’s Pocket Manual is packed with charts, conversions, photographs, diagrams, code
standards, and other information you need on the job. It even includes a chapter on tools and safety. This on-the-job reference will help you find answers quickly and easily.
Order Number: BK-0011
ISBN: 0764541994, Pages: 358, Paperback
CALL TO ORDER:
U.S. Phone 219 879-8000
•
U.K. Phone (+44) (0)1494-461707
•
Asia Pacific Phone 61 2 4272-2055
325
Temperature
• Great reference for anyone in the process, control and instrumentation
fields where measurements are essential
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertising