Carrier 50XT 024, 030, 036, 042, 048, 060 Infinity Heat Pump User manual
Below you will find brief information for 50XT 024, 50XT 030, 50XT 036, 50XT 042, 50XT 048, 50XT 060. These Carrier Infinity heat pumps offer high efficiency (up to 15.5 SEER), two-stage cooling and heating, variable-speed blower motors for comfort and dehumidification, and easy installation. They are available in various capacities (2-5 tons) and feature Puron refrigerant.
PDF
Download
Document
Advertisement
Advertisement
50XT Infinity 15t SEER Single---Packaged Heat Pump System with Puronr (R---410A) Refrigerant Single Phase 2---5 Nominal Tons (Sizes 024---060) Product Data Comfort Heat Pump System with IdealHumidityt featuring Infinityt control variable--speed blower motor and two--stage cooling and heating that provides greater comfort, humidity control, and energy efficiency. Variable--speed blower motors provide better comfort and energy efficiency. You can expect up to 30 times better dehumidification; economical constant airflow which provides improved indoor air quality and more even temperatures from room to room; and reduced indoor noise due to lower air velocity. In addition, you’ll realize improved installation flexibility with 3 different airflow choices for best overall comfort. Easy installation Factory--assembled package is a compact, fully self--contained heat pump unit that is pre--wired, pre--piped, and pre--charged for minimum installation expense. 50XT units are available in a variety of standard capacity ranges. Units install easily on a rooftop or at ground level. Durable, dependable components A05307 Fig. 1 -- Unit 50XT Single--Packaged Products with energy--saving features and Puron® refrigerant. S Up to 15.5 SEER S Up to 8.0 HSPF S Up to 12 EER at 95°F (35°C) OD S Low Sound Levels S Variable--Speed Blower (Standard) S Factory--Installed TXV S Two--stage cooling and heat pump operation FEATURES/BENEFITS One--piece Heat Pump unit with optional electric heater, low installation cost, dependable performance and easy maintenance. Efficient operation High--efficiency design with SEERs (Seasonal Energy Efficiency Ratio) of up to 15.5. Puron® environmentally--sound refrigerant is Carrier’s unique refrigerant designed to help protect the environment. Puron is an HFC refrigerant which does not contain chlorine that can harm the ozone layer. Puron refrigerant is in service in millions of systems proving highly reliable, environmentally sound performance. Compressors have two stages of cooling and heating and are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Vibration isolation provides quiet operation. Compressors have internal high--pressure and overcurrent protection. Convertible duct configuration Unit is designed for easy use in either downflow or horizontal applications. Each unit is easily converted from horizontal to downflow with two duct covers (available as an accessory). Downflow operation is easily provided in the field to allow vertical ductwork connections. The basepan utilizes knockout style seals on the bottom openings to ensure a positive seal in the horizontal airflow mode. Direct--drive, variable--speed blower motor is standard on all 50XT models. Direct--drive, PSC condenser fan motors are designed to help reduce energy consumption and provide for cooling operation down to 55°F (12.7°C) outdoor temperature. Low--ambient cooling is available below 55°F (12.7°C) when low--ambient cooling is enabled in the User Interace (UI). Motormaster® II low--ambient kit is not required. Infinityt User Interface is designed to work as a system with Carrier’s single--packaged product. Refrigerant system is designed to provide dependability. Liquid refrigerant filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with a full Puron refrigerant charge. Refrigerant service connections make checking operating pressures easier. Indoor and outdoor coils are computer designed for optimum heat transfer and cooling efficiency. The indoor coil is fabricated from copper tube and aluminum fins and is located inside the unit 1 50XT for protection against damage. The outdoor coil is internally mounted on the top tier of the unit. Copper fin coils and pre--coated fin coils are available from the factory by special order. These coils are recommended in applications where aluminum fins are likely to be damaged due to corrosion. They are ideal for seacoast applications. Thermostatic expansion valve (TXV) —A hard--shutoff, balance port TXV maintains a constant superheat at the evaporator exit (cooling cycle) resulting in higher overall system efficiency. High-- and low--pressure switches give added safety and reliability to the compressor. Low sound ratings ensure a quiet indoor and outdoor environment with sound ratings as low as 75 dBA. Easy to service cabinets provide easy single--panel accessibility to serviceable components during maintenance and installation. The basepan, with integrated drain pan, provides easy ground level installation with or without a mounting pad. Convenient handholds are provided to manipulate the unit on the job site. A nesting feature ensures a positive basepan to roof curb seal when the unit is roof mounted. A convenient 3/4--in. wide perimeter flange makes frame mounting on a rooftop easy. Louvered grille provides hail and vandalism protection for the coil. Cabinets are constructed of heavy--duty, phosphated, zinc--coated, pre--painted steel capable of withstanding 500 hrs of salt spray. Interior surfaces of the evaporator and electric heater compartments are insulated with cleanable, semi--rigid insulation board, which keeps the conditioned air from being affected by the outdoor ambient temperature and provides improved indoor air quality. (Conforms to American Society of Heating, Refrigeration and Air Conditioning Engineers No. 62P.) The sloped drain pan minimizes standing water in the unit, which is provided with an external drain. Short--cycling protection for the compressor is incorporated into our Infinity heat pump/air conditioner dual capacity control board ensuring a five--minute delay before restarting compressor after shutdown for any reason. Limited Warranty—Standard 5--year limited warranty on all parts and 10--year limited warranty on compressor. TABLE OF CONTENTS FEATURES/BENEFITS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1--2 MODEL NUMBER NOMENCLATURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 ARI CAPACITIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 PHYSICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 OPTIONS AND ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5--6 BASE UNIT DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7--8 ACCESSORY DIMENSIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 SELECTION PROCEDURE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 PERFORMANCE DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11--30 TYPICAL PIPING AND WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31 APPLICATION DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 ELECTRICAL DATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 TYPICAL WIRING SCHEMATICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 GUIDE SPECIFICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36--37 2 MODEL NUMBER NOMENCLATURE 50XT 024 ––– 3 0 1 –– Options Type of Unit 50XT - Packaged Electric Heat Pump BT CC CU TP - AL evap, vinyl condens AL evap, CU condens CU evap & condens Base unit with tin plated indoor coil hairpins TV - TP with vinyl coating on outdoor coil TC - TP with AL indoor coil and CU/CU outdoor coil Nominal Cooling Capacity 024 - 2 Ton 030 - 2.5 Ton 036 - 3 Ton 042 - 3.5 Ton 048 - 4 Ton 060 - 5 Ton Only used if ordering an option Packaging N/A LEGEND AL - Aluminum CU - Copper 50XT Series Electrical Supply 3- 208/230-1-60 ARI* CAPACITIES Cooling Capacities and Efficiencies UNIT 50XT 024 030 036 042 048 060 NOMINAL TONS 2 2--1/2 3 3--1/2 4 5 STANDARD CFM (High/Low Stage) (Cooling & Heating) 800 / 600 1000 / 700 1200 / 850 1500 / 975 1600 / 1100 1750 / 1200 NET COOLING CAPACITIES (Btuh) (High/Low Stage) 22,600 / 17,600 28,600 / 21,400 34,600 / 24,400 40,500 / 29,000 46,000 / 33,400 57,000 / 40,500 EER @A{ SEER‡ 11.4 11.6 12 11.6 11 11 15.5 15.0 15.0 15.0 15.0 14.5 Heating Capacities and Efficiencies UNIT 50XT 024 030 036 042 048 060 HIGH HEAT CAPACITY (BTUH) @ 47°F (8.3°C) (High/Low Stage) 20,800 / 16,800 27,600 / 20,400 33,600 / 23,000 39,500 / 27,600 45,500 / 32,200 56,000 / 39,500 HIGH HEAT COP @ 47°F (8.3°C) (High/Low Stage) 3.3 / 3.2 3.5 / 3.5 3.4 / 3.4 3.6 / 3.5 3.3 / 3.5 3.2 / 3.3 LOW HEAT CAPACITY (BTUH) @ 17°F (-- 8.3°C) (High/Low Stage) 11,600 / 8,400 14,000 / 9,600 17,200 / 11,200 20,600 / 14,200 25,000 / 15,200 30,800 / 20,400 { ”A” conditions---80°F (26.6°C) indoor db/67°F (19.4°C) indoor wb & 95°F (35°C) outdoor db. LOW HEAT COP @ 17°F (-- 8.3°C) (High/Low Stage) 2.2 / 1.8 2.1 / 1.9 2.4 / 1.7 2.3 / 2.0 2.4 / 1.9 2.2 / 1.9 HSPF‡ } Rated in accordance with U.S. Government DOE (Department of Energy) test procedures and/or ARI Standards 210/240. ** Tested in accordance with ARI Standard 270 ---95 (not listed in ARI). NOTES: 1. Ratings are net values, reflecting the effects of circulating fan heat. Ratings are based on: Cooling Standard: 80°F (26.6°C) db, 67°F (19.4°C) wb indoor entering ---air temperature and 95°F (35°C) db outdoor entering---air temperature. 2. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. LEGEND dBA—Sound Levels (decibels) db—Dry Bulb SEER—Seasonal Energy Efficiency Ratio wb—Wet Bulb COP—Coefficient of Performance HSPF—Heating Season Performance Factor 3 8.0 8.0 8.0 8.0 8.0 8.0 50XT PHYSICAL DATA UNIT SIZE NOMINAL CAPACITY (ton) OPERATING WEIGHT (lb) (kg) COMPRESSOR REFRIGERANT: PURON (R---410A) Quantity (lb) (kg) EXPANSION DEVICE ---HEATING ORIFICE OD (in.) --- Left ORIFICE OD (in.) --- Right EXPANSION DEVICE ---COOLING Size Part Number OUTDOOR COIL Rows…Fins/in. Face Area (sq. ft.) OUTDOOR FAN Nominal Cfm Diameter (in.) (mm) Motor HP (RPM) INDOOR COIL Rows…Fins/in. Face Area (sq. ft.) INDOOR FAN Nominal Airflow (Cfm) Comfort Efficiency Max Size (in.) (mm) Motor HP (RPM) HIGH ---PRESSURE SWITCH (psig) Cutout Reset (Auto) HIGH ---PRESSURE SWITCH 2 (psig) (Compressor Solenoid) Cutout Reset (Auto) LOSS ---OF ---CHARGE/LOW---PRESSURE SWITCH (Liquid Line) (psig) Cutout Reset (Auto) RETURN ---AIR FILTERS Throwaway (in.)* (mm) 024 2 405 184 030 2 ---1/2 435 197 036 042 3 3 ---1/2 464 476 210 216 Two ---Stage Scroll 9.7 14.0 4.4 6.4 AccuRater 0.035 0.040 0.035 0.042 TXV 3 Ton 4 Ton EA36YD139 EA36YD149 048 4 492 223 060 5 535 243 10.3 4.7 11.5 5.2 15.5 7.0 16.0 7.3 0.042 0.038 0.038 0.038 0.046 0.046 0.046 2 Ton EA36YD129 3 Ton EA36YD139 4 Ton EA36YD149 5 Ton EA36YD159 2…21 13.6 2…21 15.3 2…21 17.5 2…21 19.4 2…21 19.4 2…21 23.3 2700 22 559 1/8 (825) 2700 22 559 1/8 (825) 2800 22 559 1/8 (825) 2800 22 559 1/8 (825) 3300 22 559 1/4 (1100) 3300 22 559 1/3 (1110) 3…17 3.7 3…17 3.7 3…17 4.7 3…17 4.7 3…17 5.7 4…17 5.7 Variable based on Comfort Settings (see User Interface instructions for more information). 700 875 1050 1225 1400 1750 800 1000 1200 1400 1600 2000 10x10 10x10 11x10 11x10 11x10 11x10 254x254 254x254 279x254 279x254 279x254 279x254 1/2 1/2 3/4 3/4 3/4 1 670 ± 10 470 ± 25 565 ± 15 455 ± 15 23 ± 5 55 ± 5 20x24x1 24x30x1 24x36x1 508x610x25 610x762x25 610x914x25 *Recommended filter sizes for field---installed air filter grilles mounted on the wall or ceiling of the conditioned structure. Required filter sizes shown are based on the larger of the ARI (Air Conditioning and Refrigeration Institute) rated cooling airflow or the heating airflow velocity of 300 ft/minute for throwaway type or 450 ft/minute for high ---capacity type. Air filter pressure drop for non ---standard filters must not exceed 0.08 IN. WC. ISO 9001:2000 REGISTERED A--WEIGHTED SOUND POWER LEVEL (dBA) MODEL 50XT 024 030 036 042 048 060 STANDARD RATING (dBA) 75 75 75 75 78 78 TYPICAL OCTAVE BAND SPECTRUM (dBA) (without tone adjustment) 125 250 500 1000 2000 4000 8000 58.8 58.8 60.7 56.7 62.4 63.5 63.5 63.5 63.3 62.8 69.9 67.6 67.2 67.2 66.8 67.8 71.3 71.8 66.9 66.9 66.5 67.4 73.4 75.5 63.7 63.7 64.2 63.7 70.0 71.0 58.3 58.3 60.3 57.7 66.3 68.1 50.0 50.0 53.0 50.8 60.1 59.9 NOTE: Tested in accordance with ARI Standard 270 ---95 (not listed in ARI). 4 Factory--installed options Coil options include tin--plated* indoor hairpins, copper/copper and vinyl--coated construction for refrigerant coils. Units are shipped standard with copper tube/aluminum fin construction. See model number nomenclature for coil options. *Tin--plated indoor coils are built with special hairpins that are designed to resist both general pitting corrosion and excessive indoor corrosion (Formicary Corrosion). Field--installed accessories Manual Air Damper (25% open) Electric Heaters Filter Rack Flat Roof Curbs (8--in. and 14--in.) (203 mm and 256 mm) Square--to--Round Duct Transition Kit Infinityt User Interface Crankcase Heater Lifting Kit Compressor Hard Start Kit Manual outside air damper includes hood and filter rack with adjustable damper blade for up to 25% outdoor air. Electric heaters provide additional heat in the unit when required. Each package has a heater module that slides into the controls compartment. Heater sizes range from 5.0 to 20.0 kW. The electric heater design allows the use of a single--point power supply for the entire unit, resulting in lower installed costs. Flat roof curbs in both 8 in. (203 mm) and 14 in. (256 mm) sizes are available for roof mounted applications. Square--to--round duct transition kit enables 024--048 size units to be fitted to 14 in. round ductwork. Infinity User Interface coupled with the system’s variable--speed indoor blower delivers Carrier’s patented IdealHumidity technology that allows for even greater humidity control. Along with more precisely controlling temperature and humidity, the Infinity User Interface offers full seven--day programmability allowing you to further customize your comfort and energy savings. Lifting kit includes 4 metal brackets that are available to assist in lifting this product onto a roof application. Crankcase heater provides anti--floodback protection for low--load cooling applications. Filter rack features easy installation, serviceability, and high--filtering performance for vertical or horizontal applications. Compressor hard start kit assists compressor start--up by providing additional starting torque on single phase units and prolongs compressor motor life. Electric Heaters CATALOG ORDERING NO. NOMINAL CAPACITY (kW) USED WITH SIZES FUSED STAGES 24 30 36 42 48 60 X X X 208/240 — SINGLE PHASE (60 Hz) CPHEATER080A00 3.8 / 5.0 NO 1 CPHEATER081A00 3.8 / 5.0 YES 1 X X CPHEATER083A00 5.4 / 7.2 YES 1 X X X X X X CPHEATER085A00 7.5 / 10.0 YES 1 X X X X X X CPHEATER087A00 11.3 / 15.0 YES 2 X X X X X CPHEATER089A00 15.0 / 20.0 YES 2 X X X NOTE Electric heaters are rated at 240v. Refer to Multiplication Factors table for other voltages. X=Approved combination 5 X 50XT OPTIONS AND ACCESSORIES FILTER RACK MANUAL OUTSIDE AIR DAMPER BEND FLANGE AT 90°-SCREW TO DIVIDER WITH 1-IN. SCREW REPLACEMENT PANEL MANUAL OUTSIDE AIR HOOD TOP FILTER RACK EVAPORATOR COIL 50XT DAMPER BLADE BOTTOM FILTER RACK 6 7 Fig. 2 -- 50XT024--030 Unit Dimensions 50XT A06594 8 Fig. 3 -- 50XT036--060 Unit Dimensions 50XT A06595 ACCESSORY DIMENSIONS HVAC unit base HVAC unit base Screw (NO TE A) Gask eting inner flange* Screw (NOTE A) Gasketing inner flange* *Gasketing outer flange *Gasketing outer flange Wood nailer* Flashing field supplied Wood nailer* Flashing field supplied Roof curb* Insulation (field supplied) Roofing material field supplied Insulation (field supplied) Roofing material field supplied Ductwork field supplied Cant strip field supplied Roof curb* Ductwork field supplied Cant strip field supplied Roof Roof *Provided with roof curb *Provided with roof curb Roof Curb for Small Cabinet Roof Curb for Large Cabinet Note A: When unit mounting scre w is used, retainer bracket must also be used. Note A: When unit mounting scre w is used, retainer bracket must also be used. E G Supply opening (B x C) G B Typ. F F D CTyp. R/A S/A A E Insulated deck pan Short Support Insulated deck pan Gasket around duct D Gasket around outer edge Long Support Return opening (B X C) A05308 UNIT SIZE 024-- 030 036-- 060 CATALOG NUMBER CPRFCURB006A00 CPRFCURB007A00 CPRFCURB008A00 CPRFCURB009A00 A IN. (MM) 8 (203) 14 (356) 8 (203) 14 (356) B IN. (MM) 11 (279) 11 (279) 16--3/16 (411) 16--3/16 (411) C IN. (MM) 16--1/2 (419) 16--1/2 (419) 17--3/8 (441) 17--3/8 (441) D IN. (MM) 28--3/4 (730) 28--3/4 (730) 40--1/4 (1022) 40--1/4 (1022) E IN. (MM) 30--3/8 (771) 30--3/8 (771) 41--15/16 (1065) 41--15/16 (1065) F IN. (MM) 44--5/16 (1126) 44--5/16 (1126) 44--7/16 (1129) 44--7/16 (1129) G IN. (MM) 45--15/16 (1167) 45--15/16 (1167) 46--1/16 (1169) 46--1/16 (1169) NOTES: 1. Roof curb must be set up for unit being installed. 2. Seal strip must be applied, as required, to unit being installed. 3. Roof curb is made of 16--gauge steel. 4. Attach ductwork to curb (flanges of duct rest on curb). 5. Insulated panels: 1--in. (25 mm) thick fiberglass 1 lb. density. 6. When unit mounting screw is used (see Note A), a retainer bracket must be used as well. This bracket must also be used when required by code for hurricane or seismic conditions. This bracket is available through Micrometl. 9 50XT SUGGESTED RIGGING -in. (914 mm) DETAIL A A06296 A06298 CABINET MODEL Small 50XT--024 50XT--030 RIGGING WT lb kg 418 190 448 203 50XT--036 469 213 50XT--042 491 223 50XT--048 497 225 50XT--060 548 249 NOTE: See dimensional drawing for corner weight distribution. Corner weights shown on drawing are based on unit---only weights and do not include packaging. Large SELECTION PROCEDURE Determine cooling and heating requirements at design conditions Given: REQUIRED COOLING CAPACITY (TC) . . . . . . 34,500 BTUH SENSIBLE HEAT CAPACITY (SHC) . . . . . . . . . 24,000 BTUH REQUIRED HEATING CAPACITY (SHC) . . . . . 36,000 BTUH CONDENSER ENTERING AIR TEMPERATURE 95°F (35°C) INDOOR--AIR TEMPERATURE . . . 80°F (26.6°C) EDB, 67°F (19.4°C) EWB EVAPORATOR AIR QUANTITY . . . . . . . . . . . . . . . 1200 CFM ELECTRICAL CHARACTERISTICS . . . . . . . . . . . . . 230--1--60 Select unit based on required cooling capacity Enter the Electric Heater table on page 5 for 208/230v, single--phase, unit. The 7.2--kW heater at 240v most closely satisfies the heating required. To calculate kW at 230v, multiply the heater kW by multiplication factor 0.92 found in the Multiplication Factors table on page 29. 7.2 kW x 0.92 = 6.6 kW 6.6 kW x 3414 Btuh/kW = 22,532 Btuh Total unit heating capacity is 39,342 Btuh (16,810 + 22,532). Select unit that corresponds to power source available The Electrical Data table shows that the unit is designed to operate at 208/230--1--60. Enter Net Cooling Capacities table at condenser entering temperature of 95°F (35°C). The 036 unit at 1200 cfm and 67°F (19.4°C) ewb (entering wet bulb) will provide a total capacity of 34,600 Btuh and a SHC of 24,220 Btuh. Calculate SHC correction, if required, using Note 4 under Cooling Capacities tables. Select electric heat Enter the 036 unit Heating Extended Performance table at 1200 cfm. At 70°F (21.1°C) return indoor air and 20°F (--6.6°C) air entering outdoor coil, the integrated heating capacity is 16,810 Btuh. (Select integrated heating capacity value since deductions for outdoor--coil frost and defrosting have already been made. No correction is required.) The required heating capacity is 36,000 Btuh. Therefore, at least 19,190 Btuh additional electric heat is required. Determine additional electric heat capacity in kW. 19,190 Btuh 3414 Btuh/kW = 5.6kW of heat required 10 11 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 18.69 15.18 15.72 12.75 22.76 20.16 16.20 16.81 13.43 22.40 22.85 24.66 27.16 22.76 22.97 23.39 25.22 27.77 1.70 1.67 1.64 1.64 1.64 1.67 1.64 1.62 1.61 1.61 1.11 11.75 12.26 10.05 17.52 15.66 12.58 13.14 10.61 17.61 19.23 21.48 17.52 17.71 18.10 19.75 22.06 1.09 14.47 17.20 1.08 1.08 1.08 1.09 1.08 1.06 1.06 16.65 16.65 1.05 75 (23.8) Capacity Total MBtuh System KW Total Sens 21.77 21.77 75 (23.8) Capacity Total MBtuh System KW Total Sens See page 29 for cooling notes. 600 525 CFM EVAPORATOR AIR 50XT024 Low Cool 800 700 CFM EVAPORATOR AIR 50XT024 High Cool 12.96 16.32 15.71 21.76 21.81 12.28 15.24 14.70 18.21 20.88 1.88 1.85 1.83 1.82 1.82 1.86 1.83 1.80 1.80 1.79 20.93 18.71 17.12 16.78 16.77 20.41 18.23 16.69 16.29 15.95 10.21 12.74 12.18 16.75 16.77 9.66 11.87 11.36 14.07 15.95 1.26 1.24 1.23 1.23 1.23 1.24 1.22 1.21 1.21 1.20 85 (29.4) Capacity Total MBtuh System KW Total Sens 26.37 23.94 22.19 21.84 21.81 25.83 23.44 21.71 21.29 20.88 85 (29.4) Capacity Total MBtuh System KW Total Sens 12.48 15.82 15.21 20.81 20.81 11.80 14.75 14.21 17.70 19.95 2.09 2.05 2.03 2.03 2.03 2.06 2.03 2.01 2.00 2.00 23.35 21.18 19.62 19.74 19.74 22.94 20.79 19.25 18.95 18.94 11.95 15.30 14.69 19.74 19.74 11.29 14.24 13.70 18.95 18.94 2.31 2.28 2.26 2.26 2.26 2.29 2.26 2.23 2.23 2.23 19.72 17.60 16.09 15.96 15.96 19.26 17.18 15.70 15.34 15.21 9.80 12.32 11.76 15.96 15.96 9.26 11.47 10.96 13.65 15.21 1.43 1.41 1.39 1.39 1.39 1.41 1.39 1.38 1.37 1.37 18.41 16.41 14.98 15.10 15.10 18.02 16.05 14.64 14.40 14.40 9.36 11.88 11.32 15.10 15.10 8.84 11.03 10.53 14.40 14.40 1.62 1.60 1.59 1.59 1.59 1.60 1.58 1.57 1.57 1.57 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens 24.90 22.60 20.94 20.81 20.81 24.42 22.15 20.52 20.13 19.95 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens Cooling Extended Performance Table PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 11.41 14.74 14.14 18.58 18.58 10.76 13.70 13.16 17.86 17.86 2.57 2.53 2.51 2.51 2.51 2.54 2.51 2.48 2.48 2.48 50XT 17.03 15.14 13.80 14.15 14.15 16.69 14.83 13.50 13.52 13.52 8.91 11.41 10.85 14.15 14.15 8.39 10.58 10.07 13.52 13.52 1.85 1.83 1.81 1.82 1.82 1.83 1.81 1.80 1.80 1.80 115 (46.1) Capacity Total MBtuh System KW Total Sens 21.66 19.67 18.22 18.58 18.58 21.33 19.34 17.90 17.86 17.86 115 (46.1) Capacity Total MBtuh System KW Total Sens 11.05 14.14 13.54 17.29 17.29 10.18 13.12 12.58 16.66 16.66 2.57 2.82 2.79 2.80 2.80 2.83 2.79 2.77 2.77 2.77 15.51 13.76 12.51 13.12 13.11 15.24 13.50 12.27 12.55 12.55 8.41 10.91 10.35 13.12 13.11 7.90 10.09 9.58 12.55 12.55 2.11 2.09 2.08 2.09 2.09 2.09 2.07 2.06 2.07 2.07 125 (51.6) Capacity Total MBtuh System KW Total Sens 20.60 18.01 16.69 17.29 17.29 19.57 17.74 16.42 16.66 16.66 125 (51.6) Capacity Total MBtuh System KW Total Sens 12 700 800 700 800 700 800 CFM 4.21 4.24 3.97 4.02 3.77 3.82 700 800 700 800 700 800 CFM 16.65 16.84 16.03 16.25 14.91 15.10 14.60 14.76 14.05 14.24 13.06 13.23 1.58 1.53 1.62 1.68 1.89 1.84 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 1.12 1.11 1.25 1.24 1.38 1.38 5.89 5.95 5.63 5.71 5.36 5.43 1.21 1.20 1.35 1.34 1.49 1.48 9.38 9.46 9.01 9.12 8.62 8.74 8.61 8.69 8.27 8.37 7.91 8.02 1.32 1.31 1.46 1.45 1.61 1.59 11.90 11.94 11.51 11.60 11.03 11.17 10.85 10.89 10.49 10.58 10.06 10.19 19.30 19.36 18.69 18.95 17.97 18.27 19.30 19.36 18.69 18.95 17.97 18.27 1.69 1.61 1.86 1.79 2.03 1.96 21.15 21.27 20.68 20.80 20.04 20.30 21.15 21.27 20.68 20.80 20.04 20.30 1.75 1.66 1.95 1.85 2.14 2.05 22.00 22.16 21.51 21.65 20.96 21.13 22.00 22.16 21.51 21.65 20.96 21.13 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 6.40 6.47 6.12 6.20 5.83 5.91 1.78 1.70 1.98 1.87 2.20 2.08 Total System KW 1.42 1.43 1.55 1.55 1.70 1.69 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 3.88 3.90 3.65 3.70 3.47 3.51 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT024 High Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT024 High PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 50XT 12.90 12.94 11.21 11.30 10.75 10.88 1.45 1.44 1.49 1.66 1.75 1.72 25.14 25.40 24.54 24.82 23.91 24.20 25.14 25.40 24.54 24.82 23.91 24.20 1.92 1.82 2.11 2.00 2.32 2.21 60 (15.5) Capacity Total MBtuh System KW Total Integ 14.22 14.27 12.36 12.46 11.85 12.00 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 13 525 600 525 600 525 600 CFM 2.95 2.99 2.81 2.87 2.61 2.66 525 600 525 600 525 600 CFM 12.17 12.37 11.60 11.80 11.00 11.21 10.66 10.84 10.17 10.34 9.64 9.83 1.30 1.27 1.46 1.43 1.64 1.61 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 1.05 1.04 1.22 1.21 1.37 1.36 4.50 4.58 4.34 4.41 4.09 4.16 1.11 1.09 1.29 1.28 1.46 1.44 7.22 7.31 6.73 6.87 6.26 6.38 6.63 6.71 6.18 6.30 5.75 5.86 1.18 1.17 1.35 1.34 1.52 1.51 8.74 8.89 8.26 8.40 7.78 7.92 7.97 8.11 7.53 7.66 7.10 7.22 15.20 15.22 14.55 14.80 13.91 14.16 15.20 15.22 14.55 14.80 13.91 14.16 1.37 1.33 1.54 1.50 1.72 1.68 17.28 16.79 16.84 16.80 16.15 16.40 17.28 16.79 16.84 16.80 16.15 16.40 1.41 1.37 1.61 1.54 1.79 1.74 18.16 16.85 17.86 17.64 17.17 17.36 18.16 16.85 17.86 17.64 17.17 17.36 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 4.89 4.97 4.72 4.80 4.45 4.53 50XT 1.44 1.36 1.64 1.57 1.83 1.77 Total System KW 1.22 1.20 1.38 1.37 1.56 1.54 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 2.72 2.75 2.59 2.64 2.41 2.46 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT024 Low Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT024 Low PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 8.60 8.74 8.14 8.28 7.68 7.80 1.24 1.22 1.40 1.38 1.57 1.56 19.43 16.78 20.96 18.39 20.53 20.33 19.43 16.78 20.96 18.39 20.53 20.33 1.44 1.29 1.71 1.53 1.91 1.85 60 (15.5) Capacity Total MBtuh System KW Total Integ 9.48 9.64 8.97 9.13 8.46 8.60 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 14 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 23.85 19.34 19.99 16.13 29.10 25.68 20.61 21.34 16.96 28.72 29.28 31.48 34.49 29.10 29.40 29.91 32.13 35.18 2.18 2.14 2.10 2.10 2.09 2.14 2.10 2.07 2.06 2.05 1.36 14.40 14.96 12.26 21.32 19.04 15.36 15.98 12.91 21.55 23.40 25.95 21.32 21.67 22.13 24.00 26.61 1.34 17.65 21.08 1.32 1.31 1.31 1.35 1.32 1.30 1.30 20.32 20.32 1.29 75 (23.8) Capacity Total MBtuh System KW Total Sens 27.90 27.90 75 (23.8) Capacity Total MBtuh System KW Total Sens See page 29 for cooling notes. 700 615 CFM EVAPORATOR AIR 50XT030 Low Cool 1000 875 CFM EVAPORATOR AIR 50XT030 High Cool 16.32 20.69 19.98 27.75 27.84 15.50 19.36 18.72 23.21 26.73 2.40 2.36 2.32 2.32 2.32 2.36 2.32 2.29 2.28 2.27 25.22 22.76 20.98 20.56 20.44 24.65 22.22 20.47 20.01 19.50 12.42 15.50 14.89 18.54 20.44 11.79 14.49 13.94 17.18 19.50 1.55 1.53 1.51 1.50 1.50 1.53 1.51 1.49 1.49 1.48 85 (29.4) Capacity Total MBtuh System KW Total Sens 33.29 30.42 28.33 27.90 27.84 32.69 29.85 27.78 27.25 26.73 85 (29.4) Capacity Total MBtuh System KW Total Sens 15.65 20.02 19.31 26.48 26.48 14.85 18.70 18.07 22.53 25.47 2.65 2.60 2.57 2.56 2.56 2.61 2.56 2.53 2.52 2.52 29.11 26.64 24.86 25.00 25.00 28.70 26.23 24.46 24.09 24.09 14.94 19.30 18.60 25.00 25.00 14.15 18.00 17.38 24.09 24.09 2.92 2.87 2.83 2.84 2.84 2.88 2.83 2.80 2.79 2.79 23.71 21.40 19.74 19.46 19.46 23.20 20.93 19.28 18.86 18.60 11.90 14.98 14.38 19.46 19.46 11.28 13.99 13.44 16.67 18.60 1.76 1.74 1.72 1.72 1.72 1.75 1.72 1.70 1.70 1.70 22.06 19.91 18.38 18.38 18.38 21.63 19.51 17.99 17.62 17.60 11.34 14.42 13.83 18.38 18.38 10.73 13.44 12.90 17.58 17.60 2.01 1.99 1.97 1.97 1.97 2.00 1.97 1.95 1.95 1.95 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens 31.27 28.60 26.66 26.48 26.48 30.77 28.11 26.18 25.70 25.47 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens Cooling Extended Performance Table PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 14.18 18.53 17.84 23.34 23.34 13.40 17.25 16.64 22.56 22.56 3.22 3.17 3.13 3.15 3.15 3.18 3.13 3.10 3.10 3.10 20.25 18.29 16.90 17.17 17.17 19.91 17.97 16.58 16.49 16.20 10.74 13.82 13.24 17.17 17.17 10.14 12.85 12.33 16.49 16.20 2.30 2.28 2.26 2.26 2.26 2.28 2.26 2.24 2.24 2.21 115 (46.1) Capacity Total MBtuh System KW Total Sens 26.76 24.51 22.90 23.34 23.34 26.43 24.19 22.58 22.56 22.56 115 (46.1) Capacity Total MBtuh System KW Total Sens 50XT 13.36 16.98 17.00 21.47 21.47 13.36 16.42 15.82 20.81 20.81 3.55 3.51 3.47 3.49 3.49 3.19 3.47 3.43 3.44 3.44 18.28 16.52 15.28 15.82 15.82 18.01 16.26 15.02 15.23 15.23 10.09 13.17 12.60 15.82 15.82 9.51 12.24 11.71 15.23 15.23 2.63 2.61 2.60 2.60 2.60 2.62 2.60 2.58 2.58 2.58 125 (51.6) Capacity Total MBtuh System KW Total Sens 24.19 22.47 20.75 21.47 21.47 26.31 21.92 20.50 20.81 20.81 125 (51.6) Capacity Total MBtuh System KW Total Sens 15 875 1000 875 1000 875 1000 CFM 7.07 7.16 6.74 6.84 6.31 6.42 875 1000 875 1000 875 1000 CFM 19.48 19.75 18.76 19.03 18.00 18.32 17.07 17.31 16.44 16.67 15.77 16.05 1.91 1.89 2.11 2.08 2.31 2.28 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 1.56 1.56 1.73 1.73 1.90 1.90 8.60 8.70 8.28 8.39 7.88 8.00 1.64 1.64 1.82 1.82 2.00 2.00 12.08 12.23 11.66 11.80 11.20 11.35 11.09 11.23 10.70 10.83 10.28 10.42 1.72 1.71 1.91 1.90 2.10 2.09 14.34 14.51 13.82 14.00 13.30 13.48 13.07 13.23 12.60 12.76 12.13 12.29 24.32 24.63 23.39 23.75 22.48 22.83 24.32 24.63 23.39 23.75 22.48 22.83 2.04 2.02 2.23 2.20 2.44 2.40 28.09 28.28 27.23 27.60 26.17 26.59 28.09 28.28 27.23 27.60 26.17 26.59 2.08 2.15 2.34 2.31 2.56 2.51 29.61 30.05 29.07 29.24 27.94 28.38 29.61 30.05 29.07 29.24 27.94 28.38 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 9.35 9.46 9.00 9.12 8.56 8.69 50XT 2.12 2.19 2.40 2.34 2.62 2.57 Total System KW 1.78 1.77 1.97 1.95 2.17 2.15 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 6.51 6.59 6.20 6.29 5.81 5.91 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT030 High Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT030 High PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 13.99 14.16 13.46 13.64 12.95 13.11 1.81 1.79 2.00 1.98 2.20 2.18 35.99 36.32 35.34 35.85 34.42 34.50 35.99 36.32 35.34 35.85 34.42 34.50 2.18 2.32 2.46 2.54 2.70 2.82 60 (15.5) Capacity Total MBtuh System KW Total Integ 15.42 15.61 14.85 15.04 14.28 14.46 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 16 615 700 615 700 615 700 CFM 3.77 3.81 3.34 3.42 2.85 2.91 615 700 615 700 615 700 CFM 13.95 14.14 13.39 13.58 12.86 13.03 12.23 12.39 11.73 11.90 11.27 11.42 1.41 1.37 1.61 1.57 1.82 1.78 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 1.12 1.12 1.29 1.29 1.47 1.47 5.29 5.36 5.00 5.10 4.45 4.54 1.20 1.19 1.38 1.37 1.57 1.56 8.06 8.16 7.66 7.75 7.16 7.27 7.40 7.49 7.03 7.11 6.57 6.67 1.27 1.25 1.46 1.44 1.65 1.63 9.90 10.01 9.47 9.60 8.97 9.10 9.03 9.13 8.64 8.75 8.18 8.30 17.78 18.04 17.11 17.39 16.41 16.66 17.78 18.04 17.11 17.39 16.41 16.66 1.50 1.45 1.70 1.65 1.92 1.86 20.83 21.17 20.08 20.40 19.37 19.66 20.83 21.17 20.08 20.40 19.37 19.66 1.57 1.51 1.78 1.71 2.01 1.93 22.25 22.64 21.45 21.80 20.70 21.02 22.25 22.64 21.45 21.80 20.70 21.02 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 5.75 5.82 5.44 5.55 4.84 4.93 1.61 1.54 1.81 1.74 2.05 1.96 Total System KW 1.32 1.29 1.51 1.48 1.71 1.68 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 3.47 3.51 3.07 3.15 2.62 2.68 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT030 Low Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT030 Low PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 50XT 9.75 9.86 9.35 9.47 8.89 9.02 1.34 1.31 1.53 1.50 1.73 1.70 27.83 28.00 26.70 27.26 25.66 26.16 27.83 28.00 26.70 27.26 25.66 26.16 1.75 1.62 1.96 1.87 2.20 2.09 60 (15.5) Capacity Total MBtuh System KW Total Integ 10.75 10.87 10.31 10.45 9.80 9.94 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 17 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 28.72 23.25 24.04 18.41 35.06 30.91 24.79 25.68 19.31 34.47 35.12 37.76 42.16 35.06 35.29 35.86 38.52 42.99 2.41 2.36 2.33 2.33 2.32 2.37 2.32 2.29 2.29 2.28 1.53 16.28 16.96 13.86 24.45 21.68 17.42 18.17 14.64 24.46 26.63 29.67 24.45 24.61 25.11 27.33 30.44 1.50 20.06 23.91 1.49 1.48 1.48 1.51 1.48 1.47 1.46 23.27 23.27 1.46 75 (23.8) Capacity Total MBtuh System KW Total Sens 33.64 33.64 75 (23.8) Capacity Total MBtuh System KW Total Sens See page 29 for cooling notes. 850 745 CFM EVAPORATOR AIR 50XT036 Low Cool 1200 1050 CFM EVAPORATOR AIR 50XT036 High Cool 18.61 24.97 24.08 33.64 33.64 17.73 23.34 22.56 28.00 32.32 2.66 2.61 2.58 2.58 2.58 2.62 2.57 2.54 2.54 2.53 28.89 25.92 23.80 23.43 23.43 28.20 25.29 23.21 22.70 22.34 14.12 17.64 16.89 23.43 23.43 13.35 16.45 15.77 19.54 22.34 1.71 1.69 1.68 1.67 1.67 1.70 1.67 1.66 1.65 1.65 85 (29.4) Capacity Total MBtuh System KW Total Sens 40.85 36.62 34.09 33.64 33.64 40.12 35.94 33.44 32.83 32.32 85 (29.4) Capacity Total MBtuh System KW Total Sens 17.87 24.22 23.34 32.12 32.12 17.01 22.61 21.83 27.24 30.90 2.93 2.88 2.85 2.85 2.85 2.90 2.84 2.81 2.81 2.81 36.13 32.43 30.23 30.46 30.46 35.58 31.91 29.73 29.36 29.36 17.09 23.43 22.56 30.46 30.46 16.24 21.83 21.07 29.36 29.36 3.24 3.19 3.15 3.16 3.16 3.20 3.15 3.12 3.11 3.11 27.21 24.40 22.39 22.33 22.33 26.61 23.85 21.87 21.41 21.31 13.55 17.08 16.34 22.33 22.33 12.81 15.90 15.23 18.97 21.31 1.93 1.91 1.89 1.89 1.89 1.91 1.89 1.87 1.87 1.87 25.40 22.76 20.88 21.12 21.11 24.89 22.28 20.42 20.19 20.19 12.96 16.48 15.74 21.12 21.11 12.23 15.32 14.65 20.19 20.19 2.17 2.15 2.14 2.14 2.14 2.16 2.14 2.12 2.12 2.12 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens 38.57 34.60 32.22 32.12 32.12 37.93 34.00 31.65 31.11 30.90 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens Cooling Extended Performance Table PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 16.25 22.57 21.71 28.63 28.63 15.43 21.00 20.25 27.65 27.65 3.58 3.53 3.49 3.50 3.50 3.54 3.49 3.45 3.46 3.46 50XT 23.45 20.99 19.24 19.80 19.80 23.01 20.58 18.85 18.95 18.95 12.33 15.84 15.10 19.80 19.80 11.60 14.69 14.03 18.95 18.95 2.46 2.44 2.43 2.44 2.44 2.45 2.43 2.41 2.41 2.41 115 (46.1) Capacity Total MBtuh System KW Total Sens 33.48 30.06 28.05 28.63 28.63 33.02 29.65 27.64 27.65 27.65 115 (46.1) Capacity Total MBtuh System KW Total Sens 15.35 21.64 20.78 26.56 26.56 14.53 20.10 19.35 25.71 25.71 3.96 3.90 3.87 3.89 3.89 3.92 3.87 3.83 3.84 3.84 21.30 19.06 17.46 18.32 18.32 20.96 18.72 17.14 17.58 17.58 11.65 15.15 14.42 18.32 18.32 10.93 14.02 13.36 17.58 17.58 2.80 2.78 2.77 2.78 2.78 2.79 2.77 2.75 2.76 2.76 125 (51.6) Capacity Total MBtuh System KW Total Sens 30.56 27.47 25.66 26.56 26.56 30.21 27.14 25.33 25.71 25.71 125 (51.6) Capacity Total MBtuh System KW Total Sens 18 1050 1200 1050 1200 1050 1200 CFM 8.62 8.70 8.34 8.44 7.96 8.07 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) 1050 1200 1050 1200 1050 1200 CFM INDOOR AIR 1.43 1.43 1.59 1.59 1.74 1.74 23.95 24.20 23.16 23.44 22.38 22.66 20.99 21.21 20.29 20.54 19.61 19.86 2.22 2.20 2.44 2.41 2.67 2.64 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 7.93 8.01 7.68 7.77 7.32 7.43 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT036 High Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT036 High 10.43 10.53 10.14 10.25 9.76 9.88 1.60 1.59 1.77 1.77 1.95 1.94 14.73 14.88 14.26 14.42 13.78 13.93 13.52 13.66 13.09 13.24 12.65 12.79 1.78 1.77 1.97 1.96 2.17 2.15 17.57 17.76 16.99 17.20 16.38 16.59 16.02 16.19 15.49 15.68 14.93 15.12 29.99 30.20 28.99 29.28 28.03 28.36 29.99 30.20 28.99 29.28 28.03 28.36 2.51 2.45 2.73 2.71 2.99 2.94 34.51 34.82 33.82 33.60 32.65 33.00 34.51 34.82 33.82 33.60 32.65 33.00 2.69 2.67 2.98 2.90 3.24 3.21 36.57 36.95 35.98 35.59 34.87 34.97 36.57 36.95 35.98 35.59 34.87 34.97 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 11.33 11.45 11.02 11.14 10.60 10.74 2.79 2.74 3.08 3.00 3.37 3.29 Total System KW 1.92 1.90 2.12 2.10 2.33 2.31 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 50XT 17.15 17.33 16.61 16.81 15.99 16.19 1.99 1.97 2.19 2.17 2.40 2.38 43.09 43.39 42.90 43.10 42.66 42.80 43.09 43.39 42.90 43.10 42.66 42.80 3.12 2.88 3.44 3.30 3.75 3.69 60 (15.5) Capacity Total MBtuh System KW Total Integ 18.91 19.11 18.32 18.53 17.63 17.86 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 19 745 850 745 850 745 850 CFM 3.84 3.91 3.10 3.23 2.22 2.34 745 850 745 850 745 850 CFM 16.25 16.46 15.55 15.78 14.74 14.98 14.24 14.42 13.62 13.82 12.91 13.13 1.78 1.74 1.99 1.95 2.22 2.18 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 1.62 1.62 1.82 1.82 2.03 2.04 6.10 6.17 5.41 5.53 4.60 4.71 1.68 1.67 1.89 1.89 2.10 2.11 9.48 9.61 8.83 8.98 8.01 8.17 8.70 8.82 8.10 8.24 7.35 7.49 1.72 1.70 1.93 1.92 2.15 2.14 11.69 11.84 11.03 11.20 10.24 10.42 10.66 10.80 10.06 10.21 9.33 9.50 20.33 20.70 19.45 19.78 18.60 18.90 20.33 20.70 19.45 19.78 18.60 18.90 1.81 1.76 2.02 1.97 2.26 2.20 23.56 23.96 22.61 23.00 21.56 21.95 23.56 23.96 22.61 23.00 21.56 21.95 1.84 1.78 2.05 1.98 2.28 2.21 25.01 25.46 24.02 24.44 22.94 23.44 25.01 25.46 24.02 24.44 22.94 23.44 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 6.63 6.71 5.88 6.01 5.00 5.12 50XT 1.85 1.78 2.06 1.99 2.29 2.22 Total System KW 1.74 1.71 1.95 1.93 2.18 2.16 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 3.53 3.60 2.86 2.98 2.05 2.16 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT036 Low Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT036 Low PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 11.51 11.66 10.90 11.07 10.18 10.36 1.75 1.72 1.96 1.94 2.19 2.16 30.27 30.88 29.09 29.68 27.95 28.50 30.27 30.88 29.09 29.68 27.95 28.50 1.90 1.82 2.11 2.02 2.35 2.25 60 (15.5) Capacity Total MBtuh System KW Total Integ 12.69 12.85 12.02 12.20 11.23 11.42 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 20 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 37.05 29.94 30.93 24.77 41.96 39.80 31.90 33.01 26.04 41.24 42.00 45.04 49.21 41.96 42.17 42.81 45.87 50.09 2.96 2.89 2.84 2.83 2.82 2.91 2.84 2.78 2.77 2.76 1.91 19.56 20.31 16.51 29.53 25.99 20.89 21.71 17.40 29.61 32.05 35.41 29.53 29.77 30.34 32.81 36.21 1.91 24.09 28.99 1.90 1.90 1.90 1.89 1.89 1.89 1.89 28.20 28.20 1.89 75 (23.8) Capacity Total MBtuh System KW Total Sens 40.34 40.34 75 (23.8) Capacity Total MBtuh System KW Total Sens See page 29 for cooling notes. 975 855 CFM EVAPORATOR AIR 50XT042 Low Cool 1400 1225 CFM EVAPORATOR AIR 50XT042 High Cool 25.02 31.98 30.89 40.04 40.04 23.77 29.93 28.96 36.02 38.56 3.23 3.15 3.10 3.10 3.10 3.17 3.10 3.05 3.04 3.03 34.17 31.00 28.69 28.23 28.23 33.47 30.33 28.04 27.46 27.00 16.72 21.04 20.23 28.23 28.23 15.84 19.65 18.92 23.43 27.00 2.12 2.12 2.12 2.12 2.12 2.10 2.11 2.11 2.11 2.11 85 (29.4) Capacity Total MBtuh System KW Total Sens 47.23 43.30 40.45 40.04 40.04 46.48 42.59 39.74 39.06 38.56 85 (29.4) Capacity Total MBtuh System KW Total Sens 23.92 30.88 29.81 37.92 37.92 22.69 28.85 27.90 36.39 36.60 3.51 3.44 3.39 3.39 3.39 3.46 3.39 3.34 3.33 3.32 45.09 38.65 36.05 36.46 36.46 44.33 38.03 35.56 35.21 35.21 24.26 30.16 29.03 36.46 36.46 22.99 28.11 27.16 35.21 35.21 3.58 3.69 3.63 3.64 3.64 3.52 3.63 3.58 3.57 3.58 31.95 29.00 26.88 26.78 26.78 31.36 28.43 26.32 26.46 25.67 16.00 20.30 19.52 26.78 26.78 15.12 18.94 18.23 22.99 25.67 2.35 2.36 2.37 2.36 2.36 2.34 2.35 2.35 2.31 2.35 31.03 28.00 24.87 25.14 25.14 31.76 26.33 24.41 24.16 24.16 15.68 19.93 18.73 25.14 25.14 15.26 18.16 17.47 24.16 24.16 2.58 2.59 2.64 2.64 2.64 2.28 2.62 2.63 2.63 2.63 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens 44.13 40.50 37.88 37.92 37.92 43.50 39.90 37.29 36.71 36.60 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens Cooling Extended Performance Table PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 23.12 28.88 27.35 33.86 33.86 21.88 26.85 25.89 32.79 32.79 3.93 4.03 4.03 4.00 4.00 3.87 3.98 3.92 3.93 3.93 30.23 24.36 22.66 23.27 23.27 26.40 23.99 22.29 22.43 22.43 15.42 18.62 17.88 23.27 23.27 13.49 17.30 16.64 22.43 22.43 2.60 2.93 2.96 2.95 2.95 2.90 2.92 2.95 2.94 2.94 115 (46.1) Capacity Total MBtuh System KW Total Sens 41.83 35.36 31.99 33.86 33.86 41.24 34.81 32.52 32.79 32.79 115 (46.1) Capacity Total MBtuh System KW Total Sens 50XT 20.13 26.96 25.92 29.82 29.82 18.96 25.04 24.13 29.04 29.04 4.51 4.45 4.40 4.43 4.43 4.47 4.40 4.35 4.37 4.37 24.42 21.97 20.20 21.29 21.29 24.07 21.52 19.93 20.48 20.50 13.57 17.76 16.93 21.29 21.29 12.74 16.42 15.73 20.48 20.50 3.26 3.29 3.31 3.29 3.29 3.25 3.28 3.30 3.29 3.29 125 (51.6) Capacity Total MBtuh System KW Total Sens 32.98 30.38 28.59 29.82 29.82 32.75 30.12 28.29 29.04 29.04 125 (51.6) Capacity Total MBtuh System KW Total Sens 21 1225 1400 1225 1400 1225 1400 CFM 10.65 10.79 10.16 10.32 9.53 9.69 1225 1400 1225 1400 1225 1400 CFM 28.26 28.60 27.38 27.71 26.37 26.72 24.77 25.06 23.99 24.28 23.10 23.41 2.62 2.60 2.87 2.85 3.13 3.11 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 2.06 2.08 2.28 2.29 2.49 2.51 12.87 13.02 12.42 12.57 11.86 12.03 2.19 2.20 2.42 2.42 2.64 2.65 17.85 18.04 17.32 17.52 16.69 16.90 16.39 16.56 15.89 16.08 15.32 15.51 2.32 2.32 2.55 2.55 2.80 2.80 21.02 21.26 20.37 20.60 19.70 19.94 19.17 19.39 18.58 18.78 17.96 18.18 35.01 35.38 33.83 34.27 32.67 33.12 35.01 35.38 33.83 34.27 32.67 33.12 2.81 2.79 3.06 3.03 3.34 3.30 40.36 40.37 39.05 39.50 37.72 38.23 40.36 40.37 39.05 39.50 37.72 38.23 2.97 2.91 3.22 3.20 3.50 3.46 42.96 43.00 41.60 41.96 40.19 40.71 42.96 43.00 41.60 41.96 40.19 40.71 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 13.99 14.15 13.49 13.66 12.89 13.07 50XT 3.05 2.96 3.31 3.27 3.59 3.55 Total System KW 2.41 2.41 2.66 2.65 2.91 2.90 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 9.80 9.92 9.34 9.49 8.77 8.92 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT042 High Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT042 High PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 20.43 20.67 19.77 20.01 19.14 19.37 2.46 2.45 2.70 2.69 2.96 2.94 51.37 51.50 50.54 50.80 49.42 49.70 51.37 51.50 50.54 50.80 49.42 49.70 3.25 3.19 3.54 3.48 3.92 3.78 60 (15.5) Capacity Total MBtuh System KW Total Integ 22.53 22.79 21.80 22.06 21.10 21.36 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 22 855 975 855 975 855 975 CFM 5.94 6.03 5.11 5.22 4.12 4.22 855 975 855 975 855 975 CFM 19.99 20.23 19.18 19.44 18.27 18.54 17.51 17.72 16.81 17.03 16.01 16.24 1.99 1.95 2.21 2.17 2.46 2.41 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 1.70 1.69 1.90 1.90 2.11 2.11 8.24 8.36 7.48 7.61 6.57 6.69 1.77 1.76 1.97 1.97 2.18 2.18 12.26 12.41 11.48 11.65 10.55 10.72 11.25 11.39 10.54 10.69 9.68 9.84 1.84 1.82 2.05 2.03 2.27 2.26 14.78 14.95 14.01 14.20 13.09 13.29 13.47 13.63 12.77 12.95 11.94 12.12 24.57 24.89 23.66 23.98 22.72 23.04 24.57 24.89 23.66 23.98 22.72 23.04 2.07 2.02 2.31 2.25 2.56 2.50 28.27 28.72 27.19 27.60 26.12 26.53 28.27 28.72 27.19 27.60 26.12 26.53 2.15 2.08 2.38 2.31 2.64 2.57 30.02 30.53 28.83 29.31 27.72 28.17 30.02 30.53 28.83 29.31 27.72 28.17 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 8.96 9.08 8.13 8.27 7.14 7.27 2.18 2.11 2.42 2.34 2.68 2.60 Total System KW 1.89 1.86 2.11 2.08 2.33 2.31 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap. — Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 5.46 5.55 4.70 4.80 3.79 3.88 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT042 Low Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT042 Low PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 50XT 14.43 14.60 13.73 13.92 12.91 13.11 1.91 1.88 2.13 2.10 2.36 2.33 36.61 37.32 35.19 35.86 33.63 34.44 36.61 37.32 35.19 35.86 33.63 34.44 2.32 2.23 2.56 2.47 2.83 2.73 60 (15.5) Capacity Total MBtuh System KW Total Integ 15.91 16.10 15.14 15.35 14.24 14.46 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 23 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 38.20 30.85 32.01 25.88 46.32 41.09 32.81 34.10 27.17 45.43 46.29 50.04 55.24 46.32 46.57 47.25 51.07 56.36 3.60 3.53 3.49 3.48 3.48 3.53 3.46 3.42 3.41 3.40 2.23 22.28 23.21 19.02 33.04 29.57 23.76 24.78 20.03 33.19 36.14 40.19 33.04 33.42 34.05 37.06 41.21 2.23 27.41 32.49 2.23 2.23 2.24 2.21 2.21 2.21 2.21 31.49 31.49 2.22 75 (23.8) Capacity Total MBtuh System KW Total Sens 44.39 44.39 75 (23.8) Capacity Total MBtuh System KW Total Sens See page 29 for cooling notes. 1100 965 CFM EVAPORATOR AIR 50XT048 Low Cool 1600 1400 CFM EVAPORATOR AIR 50XT048 High Cool 26.25 33.18 31.89 44.43 44.10 24.98 31.11 29.95 37.29 42.70 3.91 3.84 3.80 3.79 3.79 3.84 3.77 3.73 3.72 3.71 39.26 35.29 32.40 31.85 31.76 38.34 34.45 31.62 30.96 30.30 19.35 24.10 23.08 28.86 31.76 18.36 22.54 21.62 26.74 30.30 2.48 2.49 2.50 2.50 2.50 2.46 2.47 2.48 2.48 2.49 85 (29.4) Capacity Total MBtuh System KW Total Sens 53.67 48.62 44.97 44.43 44.10 52.68 47.71 44.11 43.33 42.70 85 (29.4) Capacity Total MBtuh System KW Total Sens 25.29 32.20 30.92 42.54 42.54 24.04 30.16 29.00 36.31 40.87 4.25 4.18 4.13 4.13 4.13 4.18 4.11 4.06 4.05 4.05 47.69 43.19 39.95 41.40 40.41 46.96 42.50 39.28 38.87 38.88 24.26 31.17 29.90 41.40 40.41 23.04 29.14 28.00 38.87 38.88 4.62 4.55 4.50 4.51 4.51 4.55 4.48 4.43 4.43 4.43 37.19 33.40 30.64 30.39 30.39 36.37 32.65 29.95 29.34 29.02 18.64 23.38 22.37 30.39 30.39 17.67 21.84 20.92 26.03 29.02 2.77 2.78 2.80 2.80 2.80 2.75 2.77 2.78 2.78 2.78 34.96 31.39 28.77 28.90 28.90 34.25 30.72 28.14 27.64 27.63 17.88 22.62 21.61 28.90 28.90 16.93 21.10 20.18 27.57 27.63 3.10 3.12 3.14 3.13 3.13 3.08 3.10 3.12 3.12 3.12 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens 50.80 46.00 42.55 42.54 42.54 49.93 45.21 41.79 41.11 40.87 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens Cooling Extended Performance Table PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 23.15 30.06 28.80 38.04 38.04 22.53 28.60 26.91 36.67 36.67 5.03 4.96 4.91 4.92 4.92 4.52 4.43 4.84 4.84 4.84 50XT 32.54 29.20 26.73 27.27 27.27 31.95 28.62 26.19 26.10 26.10 17.07 21.81 20.81 27.27 27.27 16.14 20.30 19.39 26.10 26.10 3.48 3.51 3.53 3.52 3.52 3.46 3.49 3.52 3.51 3.51 115 (46.1) Capacity Total MBtuh System KW Total Sens 44.30 40.12 37.11 38.04 38.04 45.43 41.00 36.54 36.67 36.67 115 (46.1) Capacity Total MBtuh System KW Total Sens 22.59 29.43 27.59 36.61 36.62 20.75 26.85 25.73 35.30 34.16 5.06 4.97 5.36 4.93 4.93 5.41 5.34 5.29 4.84 5.30 29.89 26.79 24.50 25.45 25.45 29.40 26.31 24.04 24.40 24.40 16.19 20.93 19.92 25.45 25.45 15.29 19.44 18.53 24.40 24.40 3.92 3.95 3.99 3.97 3.97 3.90 3.94 3.97 3.97 3.96 125 (51.6) Capacity Total MBtuh System KW Total Sens 42.55 38.36 33.97 36.61 36.62 40.04 36.24 33.51 35.30 34.16 125 (51.6) Capacity Total MBtuh System KW Total Sens 24 1400 1600 1400 1600 1400 1600 CFM 13.33 13.53 12.72 12.94 11.86 12.09 1400 1600 1400 1600 1400 1600 CFM 33.39 33.83 32.29 32.73 31.08 31.53 29.26 29.64 28.29 28.68 27.23 27.62 3.16 3.15 3.43 3.41 3.71 3.69 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 2.19 2.21 2.39 2.41 2.58 2.61 15.98 16.18 15.40 15.62 14.63 14.88 2.40 2.42 2.62 2.64 2.84 2.86 21.89 22.14 21.24 21.52 20.40 20.70 20.10 20.32 19.50 19.75 18.73 19.00 2.63 2.64 2.87 2.88 3.11 3.12 25.47 25.78 24.70 25.00 23.85 24.18 23.23 23.51 22.52 22.79 21.74 22.05 40.69 41.16 39.25 39.82 37.81 38.39 40.69 41.16 39.25 39.82 37.81 38.39 3.49 3.48 3.77 3.74 4.07 4.04 46.59 46.62 44.95 45.50 43.28 43.94 46.59 46.62 44.95 45.50 43.28 43.94 3.77 3.72 4.05 4.04 4.37 4.33 49.36 49.42 47.65 48.12 45.87 46.54 49.36 49.42 47.65 48.12 45.87 46.54 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 17.37 17.59 16.74 16.98 15.90 16.17 3.91 3.83 4.19 4.17 4.51 4.48 Total System KW 2.80 2.80 3.05 3.05 3.31 3.31 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 12.27 12.45 11.71 11.91 10.91 11.12 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT048 High Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT048 High PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 50XT 24.61 24.92 23.83 24.14 23.04 23.36 2.88 2.88 3.13 3.13 3.40 3.40 58.12 58.16 57.17 57.23 55.65 55.70 58.12 58.16 57.17 57.23 55.65 55.70 4.29 4.22 4.65 4.57 5.07 4.92 60 (15.5) Capacity Total MBtuh System KW Total Integ 27.14 27.47 26.27 26.61 25.40 25.75 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 25 965 1100 965 1100 965 1100 CFM 5.86 5.95 5.21 5.32 4.44 4.55 965 1100 965 1100 965 1100 CFM 21.99 22.24 21.27 21.53 20.45 20.73 19.27 19.48 18.64 18.87 17.92 18.16 2.26 2.22 2.53 2.48 2.81 2.76 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 1.86 1.86 2.08 2.08 2.32 2.33 8.32 8.42 7.76 7.88 7.05 7.17 1.96 1.95 2.19 2.18 2.43 2.43 12.71 12.85 12.11 12.27 11.36 11.53 11.67 11.79 11.12 11.27 10.42 10.58 2.05 2.03 2.30 2.28 2.55 2.54 15.64 15.80 15.01 15.20 14.25 14.45 14.26 14.41 13.69 13.86 12.99 13.17 27.98 28.40 26.97 27.36 26.04 26.39 27.98 28.40 26.97 27.36 26.04 26.39 2.40 2.33 2.66 2.59 2.96 2.89 32.83 33.33 31.72 32.20 30.48 30.97 32.83 33.33 31.72 32.20 30.48 30.97 2.51 2.43 2.78 2.70 3.08 2.99 35.07 35.65 33.87 34.41 32.72 33.22 35.07 35.65 33.87 34.41 32.72 33.22 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 9.04 9.16 8.43 8.56 7.66 7.79 50XT 2.56 2.47 2.84 2.74 3.15 3.04 Total System KW 2.12 2.09 2.37 2.34 2.64 2.61 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap. — Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 5.39 5.47 4.80 4.89 4.09 4.18 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT048 Low Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT048 Low PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 15.42 15.58 14.83 15.01 14.13 14.33 2.15 2.12 2.41 2.37 2.68 2.64 43.68 44.63 41.97 42.84 40.41 41.15 43.68 44.63 41.97 42.84 40.41 41.15 2.76 2.66 3.05 2.93 3.37 3.24 60 (15.5) Capacity Total MBtuh System KW Total Integ 17.00 17.18 16.35 16.55 15.58 15.80 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 26 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) 57 (13.9) 62 (16.7) 63* (17.2) 67 (19.4) 72 (22.2) EWB _F (_C) 54.46 43.33 44.86 35.33 56.01 50.62 40.75 42.11 33.69 58.46 59.23 63.56 69.55 56.01 57.19 58.18 62.48 68.41 4.48 4.39 4.32 4.31 4.29 4.59 4.50 4.42 4.42 4.41 2.71 29.14 30.17 24.40 41.69 38.83 31.09 32.23 25.68 41.76 45.04 49.59 41.69 41.98 42.72 46.03 50.62 2.72 35.96 40.94 2.72 2.72 2.72 2.68 2.68 2.69 2.69 39.88 39.88 2.70 75 (23.8) Capacity Total MBtuh System KW Total Sens 58.24 58.24 75 (23.8) Capacity Total MBtuh System KW Total Sens See page 29 for cooling notes. 1370 1200 CFM EVAPORATOR AIR 50XT060 Low Cool 1750 2000 CFM EWB _F (_C) EVAPORATOR AIR 50XT060 High Cool 32.46 40.86 39.51 49.37 53.76 34.07 43.59 42.07 55.79 55.10 4.91 4.81 4.74 4.73 4.72 5.02 4.92 4.85 4.84 4.84 48.09 43.75 40.63 40.02 40.00 47.18 42.87 39.78 39.01 38.34 24.78 31.34 30.20 40.02 40.00 23.52 29.29 28.27 35.09 38.34 3.04 3.05 3.07 3.07 3.07 3.01 3.02 3.04 3.04 3.04 85 (29.4) Capacity Total MBtuh System KW Total Sens 65.01 59.41 55.35 54.45 53.76 66.01 60.35 56.27 55.79 55.10 85 (29.4) Capacity Total MBtuh System KW Total Sens 31.14 39.90 38.20 48.01 51.30 32.73 42.24 41.83 55.36 54.80 5.37 5.18 5.20 5.19 5.19 5.48 5.38 4.69 4.69 4.69 57.37 55.71 51.66 50.93 50.80 58.07 56.62 52.48 52.73 52.40 29.72 39.39 37.95 47.74 50.80 31.30 42.14 40.49 52.73 52.40 5.88 5.21 5.10 5.08 5.08 5.99 5.33 5.22 5.23 5.23 45.37 41.27 38.35 38.18 37.90 44.52 40.50 37.61 36.90 36.64 23.83 30.36 29.24 38.18 37.90 22.56 28.35 27.34 34.14 36.64 3.41 3.43 3.45 3.45 3.45 3.38 3.40 3.42 3.43 3.43 42.32 38.55 35.86 36.13 35.45 41.68 37.91 35.23 34.90 34.74 22.77 29.32 28.21 36.13 35.45 21.55 27.31 26.33 34.90 34.74 3.83 3.86 3.89 3.89 3.89 3.80 3.84 3.87 3.87 3.87 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens 61.35 57.00 52.28 51.51 51.30 62.20 56.88 55.68 55.36 54.80 CONDENSER ENTERING AIR TEMPERATURES _F (_C) 95 (35) 105 (40.5) Capacity Capacity Total Total MBtuh MBtuh System System KW KW Total Sens Total Sens Cooling Extended Performance Table PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 28.19 36.58 35.27 45.50 45.20 29.74 39.21 37.74 46.94 46.70 6.44 6.34 6.26 6.27 6.27 6.54 6.44 6.37 6.40 6.40 39.01 35.56 33.13 33.82 33.62 38.47 35.04 32.61 32.60 31.90 21.64 28.18 27.09 33.82 33.62 20.43 26.21 25.22 32.60 31.90 4.31 4.36 4.40 4.38 4.38 4.28 4.33 4.37 4.37 4.37 115 (46.1) Capacity Total MBtuh System KW Total Sens 52.97 48.47 45.27 45.50 45.20 53.51 48.97 45.80 46.94 46.70 115 (46.1) Capacity Total MBtuh System KW Total Sens 50XT 26.53 34.88 33.59 41.99 41.70 28.03 37.49 36.02 43.20 42.90 7.04 6.94 6.87 6.89 6.89 7.15 7.05 6.97 7.02 7.02 35.34 32.25 30.10 31.19 30.90 34.93 31.84 29.69 30.16 29.70 20.40 26.93 25.87 31.19 30.90 19.21 25.00 24.04 30.16 29.70 4.86 4.92 4.98 4.95 4.95 4.84 4.90 4.96 4.94 4.94 125 (51.6) Capacity Total MBtuh System KW Total Sens 48.09 44.00 41.16 41.99 41.70 48.46 44.37 41.56 43.20 42.90 125 (51.6) Capacity Total MBtuh System KW Total Sens 27 1750 2000 1750 2000 1750 2000 CFM 17.01 17.24 16.62 16.88 16.04 16.31 1750 2000 1750 2000 1750 2000 CFM 41.80 41.90 40.71 41.19 39.61 40.12 36.62 36.71 35.67 36.09 34.70 35.15 4.14 4.12 4.52 4.53 4.93 4.92 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 3.08 3.12 3.40 3.44 3.72 3.77 19.89 20.13 19.53 19.78 18.99 19.27 3.31 3.34 3.65 3.69 4.01 4.04 27.05 27.37 26.51 26.82 25.93 26.26 24.83 25.12 24.33 24.62 23.80 24.11 3.55 3.57 3.91 3.93 4.29 4.31 31.57 31.93 30.80 31.18 30.06 30.42 28.78 29.11 28.08 28.43 27.41 27.74 50.24 50.80 49.81 50.10 48.50 48.79 50.24 50.80 49.81 50.10 48.50 48.79 4.44 4.36 4.91 4.84 5.35 5.29 56.80 56.90 56.00 56.40 55.46 55.90 56.80 56.90 56.00 56.40 55.46 55.90 4.63 4.40 5.13 4.99 5.63 5.56 59.20 59.50 58.75 59.10 58.45 58.90 59.20 59.50 58.75 59.10 58.45 58.90 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 21.62 21.87 21.22 21.50 20.64 20.95 50XT 4.67 4.42 5.26 5.02 5.74 5.66 Total System KW 3.73 3.74 4.10 4.11 4.49 4.50 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap.— Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 70 (21.1) 80 (26.7) 60 (15.6) EDB _F (_C) INDOOR AIR 15.65 15.86 15.29 15.53 14.75 15.01 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT060 High Con’t. 70 (21.1) 80 (26.7) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT060 High PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 30.55 30.90 29.86 30.22 29.01 29.39 3.82 3.83 4.19 4.20 4.59 4.59 64.80 65.10 63.56 64.30 62.90 63.50 64.80 65.10 63.56 64.30 62.90 63.50 4.75 4.50 5.44 5.11 6.23 5.78 60 (15.5) Capacity Total MBtuh System KW Total Integ 33.69 34.08 32.92 33.32 31.99 32.41 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ 28 1200 1370 1200 1370 1200 1370 CFM 9.91 10.02 9.46 9.59 8.82 8.96 1200 1370 1200 1370 1200 1370 CFM 28.14 28.41 27.54 27.81 26.82 27.11 24.66 24.90 24.13 24.37 23.50 23.76 2.91 2.84 3.28 3.21 3.69 3.61 30 (-- 1.1) Capacity Total MBtuh System KW Total Integ 2.55 2.55 2.89 2.89 3.25 3.25 12.36 12.48 11.94 12.08 11.36 11.52 2.64 2.62 2.99 2.97 3.36 3.34 17.58 17.73 17.10 17.29 16.47 16.67 16.14 16.28 15.69 15.87 15.12 15.30 2.72 2.69 3.08 3.05 3.46 3.43 20.92 21.10 20.40 20.61 19.75 19.98 19.07 19.23 18.60 18.79 18.01 18.22 35.04 35.43 34.06 34.46 33.24 33.60 35.04 35.43 34.06 34.46 33.24 33.60 3.03 2.94 3.40 3.31 3.82 3.71 40.62 41.18 39.50 40.01 38.34 38.85 40.62 41.18 39.50 40.01 38.34 38.85 3.13 3.03 3.51 3.40 3.92 3.80 43.31 43.95 42.04 42.63 40.91 41.41 43.31 43.95 42.04 42.63 40.91 41.41 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 40 (4.4) 47 (8.3) 50 (10) Capacity Capacity Capacity Total Total MBtuh MBtuh MBtuh System System KW KW Total Integ Total Integ Total Integ 13.43 13.56 12.98 13.13 12.35 12.52 3.18 3.07 3.56 3.44 3.99 3.85 Total System KW 2.78 2.74 3.15 3.10 3.54 3.49 OUTDOOR COIL ENTERING AIR TEMPERATURES _F (_C) 0 (-- 17.7) 10 (-- 12.2) 17 (-- 8.3) Capacity Capacity Capacity Total Total Total MBtuh MBtuh MBtuh System System System KW KW KW Total Integ Total Integ Total Integ Heating Capacity LEGEND Cap. — Heating Capacity (1000 Btuh) (Includes Indoor--Fan Motor Heat) db — Dry Bulb kW — Total Power Input (Includes Compressor Motor Power Input Outdoor--Fan Motor Input, and Indoor--Fan Motor Input) rh — Relative Humidity NOTES: Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 9.11 9.22 8.70 8.82 8.11 8.24 - 10 (-- 23.3) Capacity Total MBtuh System KW Total Integ 50XT060 Low Con’t. 80 (26.7) 70 (21.1) 60 (15.6) EDB _F (_C) INDOOR AIR 50XT060 Low PERFORMANCE DATA--STANDARD ECM INDOOR MOTOR 50XT 20.36 20.54 19.88 20.08 19.29 19.51 2.81 2.76 3.18 3.13 3.57 3.52 53.58 54.06 51.83 52.74 50.19 51.04 53.58 54.06 51.83 52.74 50.19 51.04 3.38 3.19 3.77 3.62 4.21 4.04 60 (15.5) Capacity Total MBtuh System KW Total Integ 22.45 22.64 21.92 22.14 21.27 21.51 20 (-- 6.6) Capacity Total MBtuh System KW Total Integ PERFORMANCE DATA (CONT) Multiplication Factors 240 Voltage Distribution V/3/60 200 208 230 240 Multiplication Factor .69 .75 .92 1.00 LEGEND BF— Bypass Factor edb— Entering Dry--Bulb Ewb— Entering Wet--Bulb kW — Total Unit Power Input ldb— Leaving Dry--Bulb lwb— Leaving Wet--Bulb SHC— Sensible Heat Capacity (1000 Btuh) TC — Total Capacity (1000 Btuh) (net) *At 75°F (23.8°C) entering dry bulb (Tennessee Valley Authority [TVA] rating conditions); all other at 80°F (26.6°C) entering dry bulb. COOLING NOTES: 1. Ratings are net; they account for the effects of the evaporator fan motor power and heat. 2. Direct interpolation is permissible. Do not extrapolate. 3. The following formulas may be used: Example: 15.0 kW (at 240v) heater on 208v = 15.0 (.75 mult factor) = 11.25 capacity at 208v Sensible capacity (Btuh) 1.10 x cfm tldb = tedb -- tlwb = hlwb total capacity (Btuh) = hewb --4.5 x cfm Wet--- bulb temperature corresponding to enthalpy air leaving evaporator coil (hlwb) Where: hewb = Enthalpy of air entering evaporator coil 4. The SHC is based on 80_F (26.6_C) edb temperature of air entering evaporator coil. Below 80_F (26.6_C) edb, subtract (corr factor x cfm) from SHC. Above 80_F (26.6_C) edb, add (corr factor x cfm) to SHC. Correction Factor = 1.10 x (1 + BF) x (edb + 80). 5. Integrated capacity is maximum (instantaneous) capacity less the effect of frost on the outdoor coil and the heat required to defrost it. 29 50XT Heater kW Rating Wet coil air delivery -- low stage 208/230 VOLT UNIT SIZE 024 030 036 042 048 060 SYSTEM SETTING COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX 0.1 0.2 0.3 525 600 525 600 525 600 613 700 613 700 613 700 743 850 743 850 743 850 853 975 853 975 853 975 963 1100 963 1100 963 1100 1200 1372 1200 1372 1200 1372 EXTERNAL STATIC PRESSURE (in. wc) 0.4 0.5 0.6 0.7 Variable based on Comfort Settings 525 525 525 525 600 600 600 600 Variable based on Comfort Settings 613 613 613 613 700 700 700 700 Variable based on Comfort Settings 743 743 743 743 850 850 850 850 Variable based on Comfort Settings 853 853 853 853 975 975 975 975 Variable based on Comfort Settings 963 963 963 963 1100 1100 1100 1100 Variable based on Comfort Settings 1200 1200 1200 1200 1372 1372 1372 1372 0.8 0.9 1.0 525 600 525 600 525 600 613 700 613 700 613 700 743 850 743 850 743 850 853 975 853 975 853 975 963 1100 963 1100 963 1100 1200 1372 1200 1372 1200 1372 0.8 0.9 1.0 700 800 700 800 700 800 875 1000 875 1000 875 1000 1050 1200 1050 1200 1050 1200 1225 1400 1225 1400 1225 1400 1400 1600 1400 1600 1400 1600 1750 2000 1750 2000 1750 2000 Wet coil air delivery -- high stage 208/230 VOLT UNIT SIZE 024 030 036 042 048 060 SYSTEM SETTING COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX COMFORT (Default) EFFICIENCY MAX 0.1 0.2 0.3 700 800 700 800 700 800 875 1000 875 1000 875 1000 1050 1200 1050 1200 1050 1200 1225 1400 1225 1400 1225 1400 1400 1600 1400 1600 1400 1600 1750 2000 1750 2000 1750 2000 EXTERNAL STATIC PRESSURE (in. wc) 0.4 0.5 0.6 0.7 Variable based on Comfort Settings 700 700 700 700 800 800 800 800 Variable based on Comfort Settings 875 875 875 875 1000 1000 1000 1000 Variable based on Comfort Settings 1050 1050 1050 1050 1200 1200 1200 1200 Variable based on Comfort Settings 1225 1225 1225 1225 1400 1400 1400 1400 Variable based on Comfort Settings 1400 1400 1400 1400 1600 1600 1600 1600 Variable based on Comfort Settings 1750 1750 1750 1750 2000 2000 2000 2000 Air delivery values are based on operating voltage of 230v, and wet coil. Filter and electric heater will not change air delivery values. NOTES: 1. See User Interface instructions for more information on Max, Efficiency, and Comfort Settings 2. Efficiency Setting operates at 350 cfm/ton (nominal) and Max Setting operates at 400 cfm/ton (nominal) 30 TYPICAL PIPING AND WIRING ROOF-MOUNTING CURB ROOF RETURN-AIR FLEXIBLE DUCT SUPPLY-AIR FLEXIBLE DUCT CONCENTRIC DIFFUSER BOX (FIELD-SUPPLIED) CEILING C00023 USER INTERFACE RETURN AIR FROM POWER SOURCE TOP COVER DISCONNECT PER NEC* *NEC - NATIONAL ELECTRICAL CODE A06279 31 APPLICATION DATA Condensate trap — A 2--in. (51 mm) condensate trap must be field supplied. 1” (25mm) MIN. TRAP OUTLET 2” (50mm) MIN. To convert a unit to downflow discharge — Units are equipped with factory--installed inserts in the downflow openings. Remove the inserts similar to removing an electrical knock--out. Leave on duct covers to seal the horizontal discharge openings in the unit. Units installed in horizontal discharge orientation do not require duct covers. Minimum cooling ambient operating temperature — All standard units have a minimum ambient operating temperature of 55°F (12.7°C). With low--ambient cooling enabled at the UI, units can operate at temperatures down to 0°F (--17.7°C). Maximum operating outdoor air temperature — Maximum outdoor operating air temperature for cooling is 125°F (51.6°C). Ductwork — Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attach ductwork to unit with flanges. Balance Point Worksheet Building Heat Loss, 1000BTUH Unit Integrated Heating Capacity, 1000BTUH 70 Based on Entering Indoor Air of 70 Deg. F and Rated CFM 60 50 060 048 40 042 036 30 030 024 20 10 0 -20 -10 0 10 20 30 40 50 60 Outdoor Air Temp (Deg F) C03008 32 ELECTRICAL DATA UNIT SIZE V--PH--HZ VOLTAGE RANGE COMPRESSOR OFM FLA IFM FLA ELECTRIC HEAT SINGLE POINT POWER SUPPLY NOMINAL FLA MCA MOCP kW* --/---/-24.3/24.3 35/35 3.8/5.0 18.1/20.8 46.9/50.3 50/60 024 208/230--1--60 187 253 15.3 52.0 0.9 4.3 5.4/7.2 26.0/30.0 56.8/61.8 60/70 7.5/10.0 36.1/41.7 69.4/76.4 70/80 --/---/-26.2/26.2 40/40 3.8/5.0 18.1/20.8 48.7/52.2 50/60 030 208/230--1--60 187 253 16.8 70.0 0.9 4.3 5.4/7.2 26.0/30.0 58.7/63.7 60/70 7.5/10.0 36.1/41.7 71.3/78.3 80/80 11.3/15.0 54.2/62.5 93.9/104.3 100/110 --/---/-28.6/28.6 45/45 3.8/5.0 18.1/20.8 51.2/54.6 60/60 036 208/230--1--60 187 253 16.7 82.0 0.9 6.8 5.4/7.2 26.0/30.0 61.1/66.1 70/70 7.5/10.0 36.1/41.7 73.7/80.7 80/90 11.3/15.0 54.2/62.5 96.3/106.7 100/110 --/---/-34.9/34.9 50/50 3.8/5.0 18.1/20.8 57.5/60.9 60/70 5.4/7.2 26.0/30.0 67.4/72.4 70/80 042 208/230--1--60 187 253 21.8 96.0 0.9 6.8 7.5/10.0 36.1/41.7 80.0/87.0 90/90 11.3/15.0 54.2/62.5 102.6/113.0 110/125 15.0/20.0 72.2/83.3 125.2/139.1 150/150 --/---/-43.1/43.1 60/60 3.8/5.0 18.1/20.8 65.7/69.1 70/70 5.4/7.2 26.0/30.0 75.6/80.6 80/90 048 208/230--1--60 187 253 27.8 96.0 1.5 6.8 7.5/10.0 36.1/41.7 88.2/95.2 90/100 11.3/15.0 54.2/62.5 110.8/121.2 125/125 15.0/20.0 72.2/83.3 133.4/147.3 150/150 --/---/-45.2/45.2 60/60 3.8/5.0 18.1/20.8 67.7/71.2 70/80 5.4/7.2 26.0/30.0 77.6/82.7 80/90 060 208/230--1--60 187 253 27.3 118.0 1.9 9.1 7.5/10.0 36.1/41.7 90.3/97.2 100/110 11.3/15.0 54.2/62.5 112.9/123.3 125/125 15.0/20.0 72.2/83.3 135.4/149.3 150/150 *Heater capacity (kW) based on heater voltage of 208v & 240v. If power distribution voltage to unit varies from rated heater voltage, heater kW will vary accordingly. MIN MAX RLA LRA LEGEND FLA — Full Load Amps LRA — Locked Rotor Amps ® MCA — Minimum Circuit Amps MOCP — Maximum Overcurrent Protection RLA — Rated Load Amps NOTES: 1. In compliance with NEC (National Electrical Code) requirements for multimotor and combination load equipment (refer to NEC Articles 430 and 440), the overcurrent protective device for the unit shall be Power Supply fuse . The CGA (Canadian Gas Association) units may be fuse or circuit breaker. 2. Minimum wire size is based on 60 C copper wire. If other than 60 C wire is used, or if length exceeds wire length in table, determine size from NEC. 33 TYPICAL WIRING SCHEMATIC — 230--1--60 A08201 34 CONTROLS Sequence of Operation The 50XT packaged heat pump is designed for installation with a communicating UI. This unit will not respond to commands provided by a common thermostat except under certain emergency situations. The UI uses temperature, humidity and other data supplied from indoor and outdoor system components to control heating or cooling system for optimum comfort. The unit will be commanded by the UI to supply airflow. The unit will operate the indoor fan at requested airflow for most modes. The nominal requested airflow in high stage will be 350 cfm per ton of nominal cooling capacity as defined by unit size. Actual airflow request will be adjusted from nominal using indoor and outdoor temperature and indoor humidity data to optimize the system operation for occupant comfort and system efficiency. Refer to UI literature for further system control details. Airflow during electric heater operation must be greater than a minimum level for safe operation. If UI instructs unit to turn on electric heat and the requested airflow is less than the minimum level the fan coil control will override requested value. NOTE: Once the compressor has started and then has stopped, it should not be started again until 4 minutes have elapsed. The cooling cycle remains “on” until the room temperature drops to point that is slightly below the cooling control setting of the UI. COOLING AND HEATING OPERATION With a call for first stage cooling, the outdoor fan, reversing valve, and low stage compressor are energized. If low--stage cannot satisfy cooling demand, high--stage cooling is energized by the UI. After second stage is satisfied, the unit returns to low--stage operation until first stage is satisfied or until second stage is required again. When both first stage and second stage cooling are satisfied, the compressor will shut off. The reversing valve will remain energized until the control board power is removed or a call for heating is initiated. With a call for heating, the outdoor fan and compressor are energized. The compressor will operate in high or low stage operation, as needed, to meet the heating demand. When the heating demand is satisfied, the compressor and fan will shut off. The reversing valve is de--energized in the heating mode. NOTE: When two--stage unit is operating at low--stage, system vapor (suction) pressure will be higher than a standard single--stage system or high--stage operation. NOTE: Outdoor fan motor will continue to operate for one minute after compressor shuts off, when outdoor ambient is greater than or equal to 100°F (38°C). UTILITY INTERFACE WITH INFINITY CONTROL The utility curtailment relay should be connected to factory supplied pigtails (PINK connected to R, VIOLET connected to Y2 on the control board) located in the low voltage splice box (see Typical Wiring Schematic ). This input allows a power utility device to interrupt compressor operation during peak load periods. When the utility sends a signal to shut the system down, the UI will display “Curtailment Active”. Infinity Controlled Low Ambient Cooling NOTE: When this unit is operating below 55_F (12.7°C) outdoor temperature, provisions must be made for low ambient operation. This unit is capable of low ambient cooling down to 0_F (--17.7°C)ONLY when using the Infinity control. A low ambient kit is not required, and the outdoor fan motor does not need to be replaced for Infinity controlled low ambient operation. Low ambient cooling must be enabled in the UI set--up. Fan may not begin to cycle until about 40_F (4.4°C) OAT. Fan will cycle based on coil and outdoor air temperature. 35 GUIDE SPECIFICATIONS SINGLE--PACKAGED HEAT PUMP UNITS CONSTANT VOLUME APPLICATION HVAC GUIDE SPECIFICATIONS SIZE RANGE: 2 TO 5 TONS, NOMINAL (COOLING) MODEL NUMBER: 50XT PART I -- GENERAL SYSTEM DESCRIPTION Outdoor rooftop or ground mounted heat pump unit utilizing a hermetic, 2--stage scroll compressor for heating and cooling duty and optional electric heating. Unit shall discharge supply air vertically or horizontally as shown on contract drawings. Outdoor fan/coil section shall have a draw--thru design with vertical discharge for minimum sound levels. QUALITY ASSURANCE A. Unit shall be rated in accordance with ARI Standards 210/240 and 270. B. Unit shall be designed in accordance with UL Standard 1995. C. Unit shall be manufactured in a facility registered to ISO 9001 manufacturing quality standard D. Unit shall be UL listed and c--UL certified as a total package for safety requirements. E. Roof curb shall be designed to conform to NRCA Standards. F. Insulation and adhesives shall meet NFPA 90A requirements for flame spread and smoke generation. G. Cabinet insulation shall meet ASHRAE Standard 62P. DELIVERY, STORAGE, AND HANDLING Unit shall be stored and handled per manufacturer’s recommendations. 2. Fan wheel shall be made from steel, be double--inlet type. It shall have forward--curved blades with a corrosion--resistant finish and shall be dynamically balanced. 3. Outdoor fan shall be of the direct--driven propeller type with aluminum blades, riveted to corrosion--resistant steel spiders. It shall be dynamically balanced, and discharge air vertically. D. Compressor: 1. Fully hermetic, 2--stage scroll compressors with factory--installed vibration isolation. 2. Scroll compressors shall be standard on all units. 3. Compressor Protection: Defrost control shall protect compressor by preventing “short cycling.” E. Coils: 1. Indoor and outdoor coils shall have aluminum plate fins mechanically bonded to seamless copper tubes with all joints brazed. 2. Tube sheet openings shall be bellied to prevent tube wear. F. Refrigerant Metering Device: Refrigerant metering device shall be of the single body, fixed orifice feed type (outdoor) and TXV (indoor). G. Filters: Filter section shall consist of field--installed, throw--away, 1--in. thick fiberglass filters of commercially available sizes. H. Controls and Safeties: 1. Unit controls shall be complete with self--contained low voltage control circuit. 2. Units shall incorporate an internal compressor protector that provides reset capability. 3. Unit shall provide high-- and low--/loss--of--charge pressure safety protection. I. Operating Characteristics: 1. Unit shall be capable of starting and running at 125°F (51.6_C) ambient outdoor temperature, exceeding maximum load criteria of ARI Standard 240. PART 2-- PRODUCTS EQUIPMENT A. General: Factory--assembled, single--piece, heat pump. Contained within the unit enclosure shall be all factory wiring, piping, controls, refrigerant charge (R--410A), and special features required prior to field start--up. B. Unit Cabinet: 1. Unit cabinet shall be constructed of phosphated, zinc--coated, prepainted steel capable of withstanding 500 hrs of salt spray. 2. Normal service shall be through a single removable cabinet panel. 2. Compressor shall be capable of operation down to 55°F (12.7_C) ambient outdoor temperature in cooling and --10°F in heating. 3. Unit shall be capable of low--ambient cooling (below 55_F (12.7_C) ambient outdoor temperature) with low--ambient cooling enabled on the UI. J. Electrical Requirements: All unit power wiring shall enter unit cabinet at a single location. K. Motors: 1. Compressor motors shall be of the refrigerant--cooled type with line--break thermal and current overload protection. 3. The unit shall be constructed on a rust proof unit base that has an externally trapped, integrated sloped drain pan. 4. Indoor fan compartment top surface shall be insulated with a minimum 1/2--in. (13 mm) thick, flexible fiberglass insulation, coated on the air side and retained by adhesive and mechanical means. The indoor wall sections will be insulated with a foil--faced insulation capable of being wiped clean. Aluminum foil--faced fiberglass insulation shall be used in the entire indoor air cavity section. 2. All fan motors shall have permanently lubricated bearings and inherent automatic--reset thermal overload protection. 3. Outdoor fan motor shall be totally enclosed. L. Grille 1. Louvered Grille: Louvered grille shall be standard on all units. 5. Unit shall have a field--supplied condensate trap. C. Fans: 1. The indoor fan shall be variable--speed motor and control, as shown on equipment drawings. 36 GUIDE SPECIFICATIONS (CONT) 6. Filter Rack Kit: Shall provide filter mounting for downflow and horizontal applications. M. Special Features: 1. Coil Options: Shall include factory--installed optional tin--plated indoor copper/copper and vinyl--coated refrigerant coils. 7. Square--To--Round Duct Transitions: Shall have the ability to convert the supply and return openings from rectangular to round (024--048 sizes only). 2. Flat Roof Curb: Curbs shall have seal strip and a wood nailer for flashing and shall be installed per manufacturer’s instructions. 8. Crankcase Heater: Shall provide anti--floodback protection for low--load cooling applications. (Standard on 042--060 sizes.) 3. Manual Outdoor Air Damper: Package shall consist of damper, bird screen, and rain hood which can be preset to admit outdoor air for year--round ventilation. 9. Electric heaters: a. Electric heater shall be available as a field--installed option. b. Heater elements shall be open--wire type, adequately supported and insulated with ceramic bushings. c. Electric heater packages must provide single--point power connection capability. 4. Infinityt User Interface: To provide for two--stage heat pump heating, two--stage cooling, and electric (auxiliary) heat, in addition to manual or automatic changeover and indoor fan control. 10. Compressor Hard Start Kit: Shall be available to give a boost to the compressor motor at each start--up. 5. Low--Ambient Cooling: Low--ambient cooling must be enabled in the UI setup to allow unit to operate down to 0°F (--17_C) outdoor ambient temperature in cooling. 37 Copyright 2008 Carrier Corp. D 7310 W. Morris St. D Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 06/08 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 38 Catalog No: 50XT ---04PD Replaces: 50XT--- 3PD ">
Advertisement
Key features
- High SEER rating (up to 15.5)
- Two-stage cooling and heating
- Variable-speed blower motor
- IdealHumidity technology
- Easy installation
- Puron refrigerant
Frequently asked questions
Up to 15.5 SEER.
Puron (R-410A).
2-5 nominal tons (sizes 024-060).
Yes, it's standard on all models.
It provides greater humidity control and comfort.