advertisement
▼
Scroll to page 2
Model NC199 Series Commercial Water Heater Specification Sheet Job Name _______________________________________________________________________ Location ________________________________________________________________________ Architect/Engineer _______________________________________________________________ Wholesaler ______________________________________________________________________ Contractor ______________________________________________________________________ Model No. _______________________________________________________________________ Gas Type ________________________________________________________________________ No. of Units _____________________ Total BTU/hr Input _________________________________ Flow Rate (GPH) ___________________________________________________________________ Notes • Standard Input - gas consumption ranges from 16,000 BTUh to 199,900 BTUh • Compact Design - ANSI Z21.10.3/CSA 4.3 certified design that can be wall-mounted indoors with a -DVC model or installed outdoors with an -OD model • Durable Steel Casing with Acryl Coating • Heat Exchanger - manufactured with commercial grade copper, 25% thicker piping than standard models • Venting Options - available in Outdoor (-OD) or Concentric Direct Vent (-DVC) model that requires 5/3 in. Noritz concentric stainless steel pipe. • Direct Electronic Ignition • Multi-System Capability - units can be linked together by using either the optional 2-unit Quick Connect or multi-unit System Controller for up to 6 units. DVC Model • Fully Modulating - BTU input can range from 16,000 to 1.2 million BTUh (for 6-unit Multi-System) with stable combustion provided by the industry’s 1st Dual-Flame Burner • Thermal Efficiency - 84% efficient for use with natural gas or propane • Temperature Controls - includes remote thermostat that can precisely adjust the output temperature from 100°F to 180°F OD Model Model NC199 - _____ (-CA)* OD (Outdoor Vent) DVC (Concentric Direct Vent) * Canadian (-CA) model also available Accessories • Safety Devices - Flame Sensor, Overheat Prevention Device, Lightning Protection Device, Freeze Protection • Five Year Limited Heat Exchanger Warranty for Commercial Use • Five Year Limited Parts Warranty & • Approvals - CSA, UPC, NSF, Low NOx Approved By SCAQMD (Rule 1146.2) This product complies with California AB 1953 Low Lead Law and section 1417(d) of the Safe Drinking Water Act LOW-LEAD CERTIFIED R NORITZ AMERICA CORPORATION 11160 Grace Avenue, Fountain Valley, CA 92708 Tel. 1-866-7NORITZ www.noritz.com Isolator Valves (#IK-WV-7) Pipe Cover for -OD Model (#PC-2S) for -DVC Model (#PC-5S-SUS) Quick Connect Cord (#QC-1) 6-Unit System Controller for -OD Model (#SC-201-6M-EXT-OD) for -DVC Model (#SC-201-6M-EXT-DVC) Dimensions 0.4" - 1.8" 13.8" 10.6" 13.1" FLUE COLLAR 5.0" 3.1" 1.1" 2.5" 1.8" 2.9" 4.5" AIR INLET 13.8" 13.1" 8.6" 2.9" 2.1" 1.7" 23.6" 22.3" FLUE COLLAR FRONT VIEW SIDE VIEW 0.4" - 1.8" OD Model WIRING THROUGHWAY WIRING THROUGHWAY WATER DRAIN VALVE (WATER FILTER) HEIGHT OF EACH FITTING FROM BOTTOM OF CASE NC199 Series GAS INLET COLD WATER INLET HOT WATER OUTLET WATER DRAIN VALVE BOTTOM VIEW HOT WATER OUTLET 1.8" COLD WATER INLET 2.2" GAS INLET 2.2" Flow Rates Flow Rate (GPM) Flow Rate (GPH) 100 4.8 3.4 2-unit 9.6 6.8 3-unit 14.4 10.2 6-unit 28.8 20.4 1-unit 288 204 2-unit 576 408 3-unit 864 612 6-unit 1728 1224 Pressure Loss 30 50 20 Set temperature: 125°F or higher (Storage Tank Setting w/ System Controller: 170~180°F) NC199-OD NC199-DVC Supply Consumption NG: 64W Freeze 120VAC (60 Hz), LP: 77W Prevention: 145W less than 2 amps NG: 85W Freeze 40 15 30 10 20 5 10 0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 0 11.0 Flow Rate (gpm) Power Supply and Consumption Model Name 60 Set temperature: 120°F or less (Storage Tank Setting w/ System Controller: 160°F or less) 25 Ft of Head 1-unit 70 Pressure Loss (psi) Temperature Rise (°F) NOTE: For Quick-Connect and Multi-System installations, pressure loss remains constant throughout the system regardless of the number of units installed. Multiply the total the total pressure loss from the chart above. LP: 100W Prevention: 161W Temperature Settings and Options Temperature Settings Default Temperature Options 100-150°F (In 5°F intervals), 160, 170, *180°F (14 Options) 120, 130, 140, *180°F (Default is 120°F) *181.4°F actual output temperature Specification y Noritz America Corporation. The water heater(s) shall have a 5-year limited Heat Exchanger warranty and a 5-year limited Parts warranty per Noritz Limited Warranty. Unit(s) shall be designed rate capacity of _____ GPH @ 100 °F rise with rated input of _______ BTU/hr. Water heater(s) shall be vented with 3”/5” Noritz concentric stainless steel pipe (-DVC model only) at a distance not to exceed 29’ (or equivalent) with 3 elbows terminating vertically or horizontally. Water heater(s) is rated for 150 PSI working water pressure and 300 PSI test pressure. Gas supply pressure shall be 4.0“ to 10.5” WC for natural gas and 8.0“ to 14.0” WC for propane. Unit(s) shall have a coated steel case, et/outlet water connections, and water holding capacity of 0.2 gallons. The outdoor (-OD) model weighs 47 lbs. and the concentric direct vent (-DVC) model weighs 55 lbs. Unit(s) shall include features such as an adjustment for high elevation installations, temperature lockout, and 14 temperature options from 100-150°F in 5°F intervals and 160-180°F in 10°F intervals. The heater(s) shall be controlled by an internal circuit board that monitors the inlet and outlet temperatures with installed therm or. Multi-system applications that require 2 units shall be installed by connecting the units using a single cable-only connection (Quick-Connect). Applications that require 3 to 6 units shall use a multi-unit central SCAQMD rule 1146.2 Low NOx. ut notice. Rev. 06/16
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project