R410A DC Inverter VRF Series 50/60Hz
R410A DC Inverter VRF
Series 50/60Hz
Carrier InterAmerica Corporation (CIAC)
10801 NW 103rd Street Suite 1, Miami, FL 33178
www.carriercca.com
Carrier X-power VRF 2015
Cat-v.01
VRF Series 60 Hz and 50 Hz
Products Lineup
X-Power Full DC Inverter Super S Series
Capacity
Range
HP
8
10
12
14
16
18
kW
25.2
28.0
33.5
40.0
45.0
50.0
Btu/h
86,000
95,500
114,300
136,500
153,500
170,600
Appearance
03 Overview
08 X-Power Full Inverter Super S Series
X-Power Full DC Inverter Mini H Series
HP
KW
Btu/h
Capacity
Range
Appearance
3
8
27,300
4
10.5
35,830
4
12
40,950
5
14
47,770
6
16
54,600
7
20
68,240
8
22.4
76,430
20 X-Power Full DC Inverter Mini H Series
10
26
88,700
14
40
136,480
16
45
153,540
32 Indoor Units Lineup
66 Control Systems
91 Branch Pipe
01
02
Products Lineup
X-Power Full DC Inverter Super S Series
Capacity
Range
HP
8
10
12
14
16
18
kW
25.2
28.0
33.5
40.0
45.0
50.0
Btu/h
86,000
95,500
114,300
136,500
153,500
170,600
Appearance
03 Overview
08 X-Power Full Inverter Super S Series
X-Power Full DC Inverter Mini H Series
HP
KW
Btu/h
Capacity
Range
Appearance
3
8
27,300
4
10.5
35,830
4
12
40,950
5
14
47,770
6
16
54,600
7
20
68,240
8
22.4
76,430
20 X-Power Full DC Inverter Mini H Series
10
26
88,700
14
40
136,480
16
45
153,540
32 Indoor Units Lineup
66 Control Systems
91 Branch Pipe
01
02
High efficiency DC inverter compressor
Carrier X-Power VRF Air Conditioner achieves the industry's top class energy efficiency of cooling EER and
heating COP by utilizing the Brushless Reluctance DC compressor control, improved performance heat
exchanger by innovative design and numerous high performance key parts. High efficiency DC inverter
compressor reduces power consumption by 25%.
New structure enhances mid-frequency performance
Specially designed scroll profile for R410A
More compact, weight reduced by 50%
Advanced permanent magnet DC motor
improves low-frequency band performance
Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume.
Overview
Centralizing winding
Efficiency-Rotor Speed Curve
Compressor efficiency
Distributing winding
New DC motor-centralized winding
Common DC motor-distributing winding
20
40
60
80
100
Rotor speed(s-1)
Smooth 180° sine wave DC inverter
Adopting the 180° Sine Wave Inverter to smooth motor rotation greatly improves operating efficiency
compared with traditional sawtooth wave.
Common Sawtooth Wave
03
180° Sine Wave DC Inverter
04
High efficiency DC inverter compressor
Carrier X-Power VRF Air Conditioner achieves the industry's top class energy efficiency of cooling EER and
heating COP by utilizing the Brushless Reluctance DC compressor control, improved performance heat
exchanger by innovative design and numerous high performance key parts. High efficiency DC inverter
compressor reduces power consumption by 25%.
New structure enhances mid-frequency performance
Specially designed scroll profile for R410A
More compact, weight reduced by 50%
Advanced permanent magnet DC motor
improves low-frequency band performance
Powerful magnets provide high torque and efficiency and achieve 70% reduction in volume.
Overview
Centralizing winding
Efficiency-Rotor Speed Curve
Compressor efficiency
Distributing winding
New DC motor-centralized winding
Common DC motor-distributing winding
20
40
60
80
100
Rotor speed(s-1)
Smooth 180° sine wave DC inverter
Adopting the 180° Sine Wave Inverter to smooth motor rotation greatly improves operating efficiency
compared with traditional sawtooth wave.
Common Sawtooth Wave
03
180° Sine Wave DC Inverter
04
Cycle duty operation
According to the running load and system pressure, the system controls the speed of DC fan to achieve the
minimum energy consumption and best performance.
In one combination, any of the outdoor unit can run as the master unit and master unit can cycle in a period, to
realize the equal lifespan among the outdoor units. As a result extend the system lifespan significantly.
Motor speed(RPM)
High efficiency DC fan motor
DC inverter stepless
adjustment
DC motor
AC inverter
multistep adjustment
Priority
Priority
Priority
Priority
System pressure
Optimized fan grille
Optimized fan blade shape with new air outlet grille enhanced air flow volume
which greatly improves fan performance and decreases noise.
Also, a higher external static pressure has been achieved up to 40Pa. (0-20Pa is
standard, 20~40Pa should be customized.)
Backup operation
In a multiple system, if one module is failed, other modules can be backup instead of the failed one for continuing
operation.
New profile fan blade
A new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow resistance.
Running state
Stand by state
Fault or stop state
Start backup operation
Multi solenoid valves control technology
Precise oil control technology
Multi solenoid valves control technology in one system. All
the solenoid valves equipped in the unit ensure
temperature-control precisely, system running steadily and
economic to provide a comfortable environment.
5 stage oil control technology ensures every outdoor
unit & compressor’s oil always keep in the safe level,
completely solve the compressor oil lack problem.
1st stage: compressor internal oil separate
2nd stage: high efficiency oil separator (separation
efficiency up to 99%)
3rd stage: oil balance technology between compressors
4th stage: oil balance technology between modules
5th stage: intelligent system oil return program
05
2nd stage
4th stage
5th stage
1st stage
3rd stage
06
Cycle duty operation
According to the running load and system pressure, the system controls the speed of DC fan to achieve the
minimum energy consumption and best performance.
In one combination, any of the outdoor unit can run as the master unit and master unit can cycle in a period, to
realize the equal lifespan among the outdoor units. As a result extend the system lifespan significantly.
Motor speed(RPM)
High efficiency DC fan motor
DC inverter stepless
adjustment
DC motor
AC inverter
multistep adjustment
Priority
Priority
Priority
Priority
System pressure
Optimized fan grille
Optimized fan blade shape with new air outlet grille enhanced air flow volume
which greatly improves fan performance and decreases noise.
Also, a higher external static pressure has been achieved up to 40Pa. (0-20Pa is
standard, 20~40Pa should be customized.)
Backup operation
In a multiple system, if one module is failed, other modules can be backup instead of the failed one for continuing
operation.
New profile fan blade
A new blade with sharp edges and a slight curve increases the airflow rate and lowers vibration and airflow resistance.
Running state
Stand by state
Fault or stop state
Start backup operation
Multi solenoid valves control technology
Precise oil control technology
Multi solenoid valves control technology in one system. All
the solenoid valves equipped in the unit ensure
temperature-control precisely, system running steadily and
economic to provide a comfortable environment.
5 stage oil control technology ensures every outdoor
unit & compressor’s oil always keep in the safe level,
completely solve the compressor oil lack problem.
1st stage: compressor internal oil separate
2nd stage: high efficiency oil separator (separation
efficiency up to 99%)
3rd stage: oil balance technology between compressors
4th stage: oil balance technology between modules
5th stage: intelligent system oil return program
05
2nd stage
4th stage
5th stage
1st stage
3rd stage
06
Double EXV control technology
Double EXV Control Technology in one
system, each EXV part achieves 480 pulse
to adjust flow precisely. Ensure the
temperature-control precisely and steadily to
provide a comfortable envrionment.
Intelligent soft start technology
DC inverter compressor soft start function reduces strike
to the electric network. This kind of high-performance and
low sound scroll compressor operates at a faster rate
when starting, reducing start-up time. It also helps the unit
to quickly adjust the room temperature to the set level.
Starting current
(%)
Direct start
Y-△ start
Start by inverter
600
500
400
Comparison of start by inverter and by
traditional methods
300
X-Power Full Inverter
Super S Series
200
100
1
2
3
4
5
6
(Sec)
Quick warm-up & cool-down design
Fluctuation of room temperature
By utilizing the benefits of the inverter compressor,
the system can reach full load quickly and shorten
the warm-up and cool-down times to provide an
immediate and comfortable air solution.
Less temperature fluctuation will create a better
living environment.
1
2
Cooling operation
Compact design for effective use of space
Easy to transport
Compact size and light weight design minimizes the
installation footprint, reduces the installation floor load,
and is easier for transportation. For some projects the
units can even be transported through the elevator or
forklift, reduce access problem at the jobsite.
07
08
Double EXV control technology
Double EXV Control Technology in one
system, each EXV part achieves 480 pulse
to adjust flow precisely. Ensure the
temperature-control precisely and steadily to
provide a comfortable envrionment.
Intelligent soft start technology
DC inverter compressor soft start function reduces strike
to the electric network. This kind of high-performance and
low sound scroll compressor operates at a faster rate
when starting, reducing start-up time. It also helps the unit
to quickly adjust the room temperature to the set level.
Starting current
(%)
Direct start
Y-△ start
Start by inverter
600
500
400
Comparison of start by inverter and by
traditional methods
300
X-Power Full Inverter
Super S Series
200
100
1
2
3
4
5
6
(Sec)
Quick warm-up & cool-down design
Fluctuation of room temperature
By utilizing the benefits of the inverter compressor,
the system can reach full load quickly and shorten
the warm-up and cool-down times to provide an
immediate and comfortable air solution.
Less temperature fluctuation will create a better
living environment.
1
2
Cooling operation
Compact design for effective use of space
Easy to transport
Compact size and light weight design minimizes the
installation footprint, reduces the installation floor load,
and is easier for transportation. For some projects the
units can even be transported through the elevator or
forklift, reduce access problem at the jobsite.
07
08
Features
N of
Outdoor
Units
No of
Compressors
8HP
1
1
10HP
1
1
12HP
1
2
14HP
1
2
16HP
1
2
*18HP
1
2
20HP
2
2
22HP
2
24HP
2
26HP
o
8HP
10HP
12HP
14HP
16HP
*18HP
Maximum No
of Connectable
Indoor Units
Capacity
Cooling
Heating
kW
kBtu/h
kW
kBtu/h
13
25.2
86.0
27.0
92.1
16
28.0
95.5
31.5
107.5
20
33.5
114.3
37.5
128.0
23
40.0
136.5
45.0
153.5
26
45.0
153.5
50.0
170.6
29
50.0
170.6
56.0
191.1
2
33
56.0
191.1
63.0
215.0
3
1
36
61.5
209.8
69.0
235.4
3
1
39
68.0
232.0
76.5
261.0
2
3
1
43
73.0
249.1
81.5
278.1
28HP
2
3
1
46
78.0
266.1
87.5
298.6
30HP
2
4
1
50
85.0
290.0
95.0
324.1
32HP
2
4
1
1
53
90.0
307.1
101.0
344.6
34HP
2
4
1
56
95.0
324.1
106.0
361.7
36HP
2
4
2
59
100.0
341.2
112.0
382.1
38HP
3
4
2
1
63
106.0
361.7
119.0
406.0
40HP
3
5
1
64
113.0
385.6
126.5
431.6
42HP
3
5
64
120.0
409.4
135.0
460.6
44HP
3
5
1
1
64
123.0
419.7
137.5
469.2
46HP
3
5
1
2
64
128.0
436.7
143.5
489.6
48HP
3
6
1
1
64
135.0
460.6
151.0
515.2
50HP
3
6
1
2
64
140.0
477.7
157.0
535.7
52HP
3
6
2
64
145.0
494.7
162.0
552.7
54HP
3
6
3
64
150.0
511.8
168.0
573.2
56HP
4
6
2
2
64
156.0
532.3
175.0
597.1
58HP
4
7
1
1
1
64
163.0
556.2
182.5
622.7
60HP
4
7
1
1
2
64
168.0
573.2
188.5
643.2
2
64
173.0
590.3
193.5
660.2
3
64
178.0
607.3
199.5
680.7
2
64
185.0
631.2
207.0
706.3
3
64
190.0
648.3
213.0
726.8
3
64
195.0
665.3
218.0
743.8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
7
1
64HP
4
7
1
66HP
4
8
1
68HP
4
8
1
70HP
4
8
4
1
3
62HP
72HP
1
1
1
1
1
8
4
64
200.0
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27°C(80.6°F) DB/19°C(66.2°F) WB; Outdoor temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: Indoor temperature 20°C(68°F) DB/15°C(59°F) WB; Outdoor temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping length: Interconnecting piping length is 7.5m(24.6ft), level difference is zero.
The above combination models are factory-recommended models.
*18HP model is customized.
682.4
224.0
764.3
Wide Application Range
Wide range of outdoor units
The outdoor units capacity range from 8HP up to 72HP in 2HP increment. Maximum 64 indoor units with
capacity up to 130% of total outdoor units can be connected in one refrigeration system.
8, 10HP
12, 14, 16HP
18, 20, 22, 24, 26, 28, 30, 32HP
18HP
50, 52, 54, 56, 58, 60, 62, 64HP
34,36, 38, 40, 42, 44, 46, 48HP
66, 68, 70, 72HP
Large connectable indoor units quantity
The large quantity of connectable units is suitable for large buildings and projects.
70
64
65
59
60
55
53
50
46
45
39
40
33
35
30
26
25
20
20
15
13
10
5
09
72HP
70HP
68HP
66HP
64HP
62HP
60HP
58HP
56HP
54HP
52HP
50HP
48HP
46HP
44HP
42HP
40HP
38HP
36HP
34HP
32HP
30HP
28HP
26HP
24HP
22HP
20HP
18HP
16HP
14HP
12HP
8HP
0
10HP
Model
Outdoor Unit Combination
Number of connectable indoor unit
Recommended combination table
10
Features
N of
Outdoor
Units
No of
Compressors
8HP
1
1
10HP
1
1
12HP
1
2
14HP
1
2
16HP
1
2
*18HP
1
2
20HP
2
2
22HP
2
24HP
2
26HP
o
8HP
10HP
12HP
14HP
16HP
*18HP
Maximum No
of Connectable
Indoor Units
Capacity
Cooling
Heating
kW
kBtu/h
kW
kBtu/h
13
25.2
86.0
27.0
92.1
16
28.0
95.5
31.5
107.5
20
33.5
114.3
37.5
128.0
23
40.0
136.5
45.0
153.5
26
45.0
153.5
50.0
170.6
29
50.0
170.6
56.0
191.1
2
33
56.0
191.1
63.0
215.0
3
1
36
61.5
209.8
69.0
235.4
3
1
39
68.0
232.0
76.5
261.0
2
3
1
43
73.0
249.1
81.5
278.1
28HP
2
3
1
46
78.0
266.1
87.5
298.6
30HP
2
4
1
50
85.0
290.0
95.0
324.1
32HP
2
4
1
1
53
90.0
307.1
101.0
344.6
34HP
2
4
1
56
95.0
324.1
106.0
361.7
36HP
2
4
2
59
100.0
341.2
112.0
382.1
38HP
3
4
2
1
63
106.0
361.7
119.0
406.0
40HP
3
5
1
64
113.0
385.6
126.5
431.6
42HP
3
5
64
120.0
409.4
135.0
460.6
44HP
3
5
1
1
64
123.0
419.7
137.5
469.2
46HP
3
5
1
2
64
128.0
436.7
143.5
489.6
48HP
3
6
1
1
64
135.0
460.6
151.0
515.2
50HP
3
6
1
2
64
140.0
477.7
157.0
535.7
52HP
3
6
2
64
145.0
494.7
162.0
552.7
54HP
3
6
3
64
150.0
511.8
168.0
573.2
56HP
4
6
2
2
64
156.0
532.3
175.0
597.1
58HP
4
7
1
1
1
64
163.0
556.2
182.5
622.7
60HP
4
7
1
1
2
64
168.0
573.2
188.5
643.2
2
64
173.0
590.3
193.5
660.2
3
64
178.0
607.3
199.5
680.7
2
64
185.0
631.2
207.0
706.3
3
64
190.0
648.3
213.0
726.8
3
64
195.0
665.3
218.0
743.8
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
4
7
1
64HP
4
7
1
66HP
4
8
1
68HP
4
8
1
70HP
4
8
4
1
3
62HP
72HP
1
1
1
1
1
8
4
64
200.0
Notes:
Capacities are based on the following conditions:
Cooling: Indoor temperature 27°C(80.6°F) DB/19°C(66.2°F) WB; Outdoor temperature 35°C(95°F) DB/24°C(75.2°F) WB
Heating: Indoor temperature 20°C(68°F) DB/15°C(59°F) WB; Outdoor temperature 7°C(44.6°F) DB/6°C(42.8°F) WB
Piping length: Interconnecting piping length is 7.5m(24.6ft), level difference is zero.
The above combination models are factory-recommended models.
*18HP model is customized.
682.4
224.0
764.3
Wide Application Range
Wide range of outdoor units
The outdoor units capacity range from 8HP up to 72HP in 2HP increment. Maximum 64 indoor units with
capacity up to 130% of total outdoor units can be connected in one refrigeration system.
8, 10HP
12, 14, 16HP
18, 20, 22, 24, 26, 28, 30, 32HP
18HP
50, 52, 54, 56, 58, 60, 62, 64HP
34,36, 38, 40, 42, 44, 46, 48HP
66, 68, 70, 72HP
Large connectable indoor units quantity
The large quantity of connectable units is suitable for large buildings and projects.
70
64
65
59
60
55
53
50
46
45
39
40
33
35
30
26
25
20
20
15
13
10
5
09
72HP
70HP
68HP
66HP
64HP
62HP
60HP
58HP
56HP
54HP
52HP
50HP
48HP
46HP
44HP
42HP
40HP
38HP
36HP
34HP
32HP
30HP
28HP
26HP
24HP
22HP
20HP
18HP
16HP
14HP
12HP
8HP
0
10HP
Model
Outdoor Unit Combination
Number of connectable indoor unit
Recommended combination table
10
High Efficiency
Wide operation range
High COP/EER values
COOLING MODE
-5°C
(23°F)
48°C
(118.4°F)
Outdoor Temperature
Heating
-2 0
(-4°F)
-1 0
0
(32°F)
kBtu/h
24°C
(75.2°F)
Outdoor Temperature
(14°F)
10
(50°F)
20
(68°F)
30
(86°F)
40
3.97
4.39
3.81
3.54
3.4
14HP
16HP
4.17
4.17
4.02
3.89
3.91
3.38
(122°F)
Outdoor temperature (DB)
8HP
10HP
12HP
18HP
8HP
10HP
12HP
14HP
16HP
18HP
All DC inverter technology
Long piping length
m
ft.
1000*
3280*
Actual length
175
574
Equivalent length
200
656
40/90*
131.2/295.2*
Outdoor unit up
70
229.6
Outdoor unit down
110
360.8
30
98.4
Total piping length (Actual)
Piping length
Level difference
between IDU-IDU is 30m(98.4ft.)
Level difference between IDU-ODU is 110m(360.8ft.)
Permitted value
90m(295.2ft.)
COP
50
(104°F)
The X-Power series system operates stably at extreme temperatures ranging from -20°C(-4°F) to 48°C(118.4°F).
Longest actual piping length 175m(574ft.)
EER
4.29
HEATING MODE*
-20°C
(-4°F)
The cooling EER up to 4.29 and the heating COP up to 4.39 in the 8HP category.
All DC inverter compressors make the capacity output better distributed, and always work at 60-120Hz which
is the most efficient range. It makes the efficiency more than 30% higher than the normal.
All DC Inverter Compressors
Longest piping
Equivalent piping length from the farthest
IDU to the first indoor branch joint
Level difference
between IDU~ODU
Level difference
Level difference between IDU~IDU
New structure enhances mid-frequency performance
Specially designed scroll profile for R410A
More compact, weight reduced by 50%
Advanced permanent magnet DC motor improves
the low frequency band performance
*Total pipe length is equal to two times
pipe length plus.
*When the piping length from the farthest IDU to the first indoor branch joint is more than
40m(131.2ft.), it needs to meet specific conditions according to the installation part of the
technical manual to achieve 90m(295.2ft.).
60Pa
Motor speed(RPM)
According to the running load and system pressure, the system controls the speed of DC fan to achieve the
minimum energy consumption and best performance.
High external static pressure
Max. 60Pa(0.24” W.G.) external static pressure can be
customized for the outdoor unit, flexible to build-in installation.
A standard 0-20Pa(0-0.08” W.G.) external static pressure is
equipped by default for all outdoor units. 0-40Pa(0-0.16” W.G.)
external static pressure can be customized for 8, 10, 14, 16HP
outdoor units, and 0-60Pa(0-24” W.G.) can be customized for
12HP outdoor unit.
All DC Fan Motors
DC inverter stepless
adjustment
AC inverter
multistep adjustment
System pressure
11
12
High Efficiency
Wide operation range
High COP/EER values
COOLING MODE
-5°C
(23°F)
48°C
(118.4°F)
Outdoor Temperature
Heating
-2 0
(-4°F)
-1 0
0
(32°F)
kBtu/h
24°C
(75.2°F)
Outdoor Temperature
(14°F)
10
(50°F)
20
(68°F)
30
(86°F)
40
3.97
4.39
3.81
3.54
3.4
14HP
16HP
4.17
4.17
4.02
3.89
3.91
3.38
(122°F)
Outdoor temperature (DB)
8HP
10HP
12HP
18HP
8HP
10HP
12HP
14HP
16HP
18HP
All DC inverter technology
Long piping length
m
ft.
1000*
3280*
Actual length
175
574
Equivalent length
200
656
40/90*
131.2/295.2*
Outdoor unit up
70
229.6
Outdoor unit down
110
360.8
30
98.4
Total piping length (Actual)
Piping length
Level difference
between IDU-IDU is 30m(98.4ft.)
Level difference between IDU-ODU is 110m(360.8ft.)
Permitted value
90m(295.2ft.)
COP
50
(104°F)
The X-Power series system operates stably at extreme temperatures ranging from -20°C(-4°F) to 48°C(118.4°F).
Longest actual piping length 175m(574ft.)
EER
4.29
HEATING MODE*
-20°C
(-4°F)
The cooling EER up to 4.29 and the heating COP up to 4.39 in the 8HP category.
All DC inverter compressors make the capacity output better distributed, and always work at 60-120Hz which
is the most efficient range. It makes the efficiency more than 30% higher than the normal.
All DC Inverter Compressors
Longest piping
Equivalent piping length from the farthest
IDU to the first indoor branch joint
Level difference
between IDU~ODU
Level difference
Level difference between IDU~IDU
New structure enhances mid-frequency performance
Specially designed scroll profile for R410A
More compact, weight reduced by 50%
Advanced permanent magnet DC motor improves
the low frequency band performance
*Total pipe length is equal to two times
pipe length plus.
*When the piping length from the farthest IDU to the first indoor branch joint is more than
40m(131.2ft.), it needs to meet specific conditions according to the installation part of the
technical manual to achieve 90m(295.2ft.).
60Pa
Motor speed(RPM)
According to the running load and system pressure, the system controls the speed of DC fan to achieve the
minimum energy consumption and best performance.
High external static pressure
Max. 60Pa(0.24” W.G.) external static pressure can be
customized for the outdoor unit, flexible to build-in installation.
A standard 0-20Pa(0-0.08” W.G.) external static pressure is
equipped by default for all outdoor units. 0-40Pa(0-0.16” W.G.)
external static pressure can be customized for 8, 10, 14, 16HP
outdoor units, and 0-60Pa(0-24” W.G.) can be customized for
12HP outdoor unit.
All DC Fan Motors
DC inverter stepless
adjustment
AC inverter
multistep adjustment
System pressure
11
12
Enhanced Comfort
High performance heat exchanger
Original design
0.6
0.4
Original design
Reduce
28%
0.2
New design
0
0
200
400
600
800
1000
Re
Night silent operation will be
activated X hours after the peak
temperature during daytime,
and it will go back to normal
operation after Y hours.
0.8
Reduce
30%
Original design
0.6
0
0
0.2
0.4
0.6
0.8
1
Relative frosting rate
Night silent Mode
noise
Max.-10dB(10Hp)
Start
08:00
14:00
Notes:
This function can be activated by setting at site.
End
22:00
08:00
Temperature(load) curve shown in the graph is just an example.
Intelligent defrosting
Intelligent defrosting program will judge the defrosting
time according to the system real requirement, reduce
the heating loss by unnecessary defrosting and make
the indoor side more comfortable.
Defrosting time can be shortened to 4 min. due to the
specialized defrosting valve.
Usual defrosting
t min
Δt
Time
Easier Installation and Service
Original design
Gas
Liquid
Simple signal line connection
Liquid
Centralized controller (CRF-10-CM or CRF-30-CM) can be connected from indoor side or outdoor side (XYE
terminals) at will. Only one group of communication wire of PQE, achieved both of communication for indoor &
outdoor unit. It’s more convenient for communication wiring.
New design
Gas
Gas-Liquid
Liquid
Liquid
Common
Design
Sub-cooling
Technology
PQ E
Increase the hot liquid rate in the condenser
Improve the heat-exchange efficiency
X Y E
Innovative designed high efficiency heat exchanger, which can reach up to 12oC(21.6oF) subcooling
degree, reduces the system resistance and improves reliability.
When the outdoor temperature is 35oC(95oF), the refrigerant can be cooled down to 37.1oC(98.8oF),
thus achieving high heat-exchanging efficiency with only 2.1oC(3.8oF) temperature difference.
13
10hrs
8hrs
New design
0.2
Hydrophilic film fins + inner-threaded pipes
Gas
50
Intelligent defrosting technology
0.4
The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more power
and enhance heat exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
Gas
Peak value of ambient temp.
100
Heating capacity
High efficiency inner-threaded pipe,
enhance heat transfer.
Relative windage resistance
Frost contrast
-Mode 1→X: 6 hours, Y: 10 hours
-Mode 2→X: 8 hours, Y: 10 hours
-Mode 3→X: 6 hours, Y: 12 hours
-Mode 4→X: 8 hours, Y: 8 hours
Load % Capacity %
High comfort outdoor unit’s multi-choice of silent mode during the night.
Super silent operation mode can reduce sound level further, minimum 45dB (A).
0.8
Noise dB
Reduce air resistance.
Night silent operation mode
Windage& air flow
Relative windage resistance
New design
X Y E
P Q E
P Q E
PQ E
P Q E
Auto addressing
Outdoor unit can distribute addresses for indoor
unit automatically.
Wireless and wired controllers can query and
modify each indoor unit's address.
14
Enhanced Comfort
High performance heat exchanger
Original design
0.6
0.4
Original design
Reduce
28%
0.2
New design
0
0
200
400
600
800
1000
Re
Night silent operation will be
activated X hours after the peak
temperature during daytime,
and it will go back to normal
operation after Y hours.
0.8
Reduce
30%
Original design
0.6
0
0
0.2
0.4
0.6
0.8
1
Relative frosting rate
Night silent Mode
noise
Max.-10dB(10Hp)
Start
08:00
14:00
Notes:
This function can be activated by setting at site.
End
22:00
08:00
Temperature(load) curve shown in the graph is just an example.
Intelligent defrosting
Intelligent defrosting program will judge the defrosting
time according to the system real requirement, reduce
the heating loss by unnecessary defrosting and make
the indoor side more comfortable.
Defrosting time can be shortened to 4 min. due to the
specialized defrosting valve.
Usual defrosting
t min
Δt
Time
Easier Installation and Service
Original design
Gas
Liquid
Simple signal line connection
Liquid
Centralized controller (CRF-10-CM or CRF-30-CM) can be connected from indoor side or outdoor side (XYE
terminals) at will. Only one group of communication wire of PQE, achieved both of communication for indoor &
outdoor unit. It’s more convenient for communication wiring.
New design
Gas
Gas-Liquid
Liquid
Liquid
Common
Design
Sub-cooling
Technology
PQ E
Increase the hot liquid rate in the condenser
Improve the heat-exchange efficiency
X Y E
Innovative designed high efficiency heat exchanger, which can reach up to 12oC(21.6oF) subcooling
degree, reduces the system resistance and improves reliability.
When the outdoor temperature is 35oC(95oF), the refrigerant can be cooled down to 37.1oC(98.8oF),
thus achieving high heat-exchanging efficiency with only 2.1oC(3.8oF) temperature difference.
13
10hrs
8hrs
New design
0.2
Hydrophilic film fins + inner-threaded pipes
Gas
50
Intelligent defrosting technology
0.4
The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more power
and enhance heat exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
Gas
Peak value of ambient temp.
100
Heating capacity
High efficiency inner-threaded pipe,
enhance heat transfer.
Relative windage resistance
Frost contrast
-Mode 1→X: 6 hours, Y: 10 hours
-Mode 2→X: 8 hours, Y: 10 hours
-Mode 3→X: 6 hours, Y: 12 hours
-Mode 4→X: 8 hours, Y: 8 hours
Load % Capacity %
High comfort outdoor unit’s multi-choice of silent mode during the night.
Super silent operation mode can reduce sound level further, minimum 45dB (A).
0.8
Noise dB
Reduce air resistance.
Night silent operation mode
Windage& air flow
Relative windage resistance
New design
X Y E
P Q E
P Q E
PQ E
P Q E
Auto addressing
Outdoor unit can distribute addresses for indoor
unit automatically.
Wireless and wired controllers can query and
modify each indoor unit's address.
14
Specifications
Specifications
X-Power Full Inverter Super S Series
X-Power Full Inverter Super S Series
38VF008H117010
38VF008H118010
38VF010H117010
38VF010H118010
V-Ph-Hz
208/230V 3~60Hz
220V 3~50Hz
208/230V 3~60Hz
220V 3~50Hz
kW
25.2
28
33.5
RT
7.2
8
9.6
Model
Power supply
Capacity
Cooling (*1)
Input
kW
5.88
7.05
8.80
4.29
3.97
3.81
kW
27
31.5
37.5
RT
7.7
9.0
10.7
Input
kW
6.15
7.55
9.00
COP
kW/kW
4.39
4.17
4.17
%
50-130%
50-130%
50-130%
13
16
20
dB(A)
57
57
59
Liquid side
mm
Ф12.7
Ф12.7
Ф15.9
Gas side
mm
Ф25.4
Ф31.8
Oil balance pipe
mm
Ф6.4
Capacity
Connectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Pipe connections
Quantities
V-Ph-Hz
208/230V 3~60Hz
220V 3~50Hz
208/230V 3~60Hz
220V 3~50Hz
208/230V 3~60Hz
220V 3~50Hz
Capacity
kW
40
45
50
Cooling (*1)
RT
11.4
12.9
14.3
13.2
14.8
3.4
3.38
kW
45
50
56
RT
12.9
14.3
16.0
Input
kW
11.20
12.8
14.4
COP
kW/kW
4.02
3.91
3.89
%
50-130%
50-130%
50-130%
23
26
29
dB(A)
61
62
62
Liquid side
mm
Ф15.9
Ф15.9
Ф19.1
Gas side
mm
Ф31.8
Ф31.8
Ф31.8
Ф6.4
Oil balance pipe
mm
Ф6.4
Ф6.4
Ф6.4
1+1
Quantities
1+1
1+1
2
Type
DC
DC
31.59 +11.80
Btu/h
107800
107800
107800+40300
Input
W
10340
10340
10340+3665
Crankcase
W
27.6×2
27.6×2
27.6×2×2
Type
FVC68D
FVC68D
FVC68D
Input
EER
Capacity
Heating (*2)
Coneectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Pipe connections
DC
DC
DC
Btu/h(W)
31.59 +11.80
31.59 +11.80
31.590 +31.59
Btu/h
107800+40300
107800+40300
107800+107800
Input
W
10340+3665
10340+3665
10340 +10340
Crankcase
W
27.6×2×2
27.6×2×2
27.6×2×2
Type
FVC68D
FVC68D
FVC68D
ml
500+1200
500+1200
500 + 500
DC motor
DC motor
DC motor
2
2
2
CFM
9200
9200
9200
3
m /h
15620
15620
15620
Output
W
390×2(rated)
390×2(rated)
565×2
ESP.
pa
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
Capacity
Compressor
Refrigerant oil
500
500
500+1200
DC motor
DC motor
DC motor
1
1
2
CFM
6620
6620
7660
m3/h
11242
11242
13000
Output
W
450(rated)
450(rated)
230×2(rated)
ESP.
pa
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
Dimension(W×H×D)
mm
960×1615×765
960×1615×765
1250×1615×765
Dimension(W×H×D)
mm
1250×1615×765
1250×1615×765
1250×1615×765
Packing(W×H×D)
mm
1025×1790×830
1025×1790×830
1305×1790×820
Packing(W×H×D)
mm
1305×1790×820
1305×1790×820
1305×1790×820
Net/Gross weight
kg
202/218
202/218
285/305
Net/Gross weight
kg
285/305
288/308
310/330
R410A
R410A
R410A
R410A
R410A
R410A
9
9
11
kg
13
13
16
EXV
EXV
EXV
Mpa
4.4/2.6
4.4/2.6
4.4/2.6
Cooling
℃
-5~48
-5~48
-5~48
Heating
℃
-20~24
-20~24
-20~24
Quantities
Air flow rate
type
volume
kg
Throttle type
EXV
EXV
EXV
Mpa
4.4/2.6
4.4/2.6
4.4/2.6
Cooling
℃
-5~48
-5~48
-5~48
Heating
℃
-20~24
-20~24
-20~24
Design pressure (High/low)
15
Power supply
3.54
31.59
Type
Ambient temperature range
38VF018H117010
38VF018H118010
11.30
DC
ml
38VF016H117010
38VF016H118010
kW
31.59
Refrigerant oil
Charged refrigerant
1
38VF014H117010
38VF014H118010
Model
kW/kW
Btu/h(W)
Capacity
Fan Motor
Ф6.4
1
Type
Compressor
208/230V 3~60Hz
220V 3~50Hz
kW/kW
EER
Heating (*2)
38VF012H117010
38VF012H118010
Type
Quantities
Fan Motor
Charged refrigerant
Air flow rate
type
volume
Throttle type
Design pressure (High/low)
Ambient temperature range
16
Specifications
Specifications
X-Power Full Inverter Super S Series
X-Power Full Inverter Super S Series
38VF008H117010
38VF008H118010
38VF010H117010
38VF010H118010
V-Ph-Hz
208/230V 3~60Hz
220V 3~50Hz
208/230V 3~60Hz
220V 3~50Hz
kW
25.2
28
33.5
RT
7.2
8
9.6
Model
Power supply
Capacity
Cooling (*1)
Input
kW
5.88
7.05
8.80
4.29
3.97
3.81
kW
27
31.5
37.5
RT
7.7
9.0
10.7
Input
kW
6.15
7.55
9.00
COP
kW/kW
4.39
4.17
4.17
%
50-130%
50-130%
50-130%
13
16
20
dB(A)
57
57
59
Liquid side
mm
Ф12.7
Ф12.7
Ф15.9
Gas side
mm
Ф25.4
Ф31.8
Oil balance pipe
mm
Ф6.4
Capacity
Connectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Pipe connections
Quantities
V-Ph-Hz
208/230V 3~60Hz
220V 3~50Hz
208/230V 3~60Hz
220V 3~50Hz
208/230V 3~60Hz
220V 3~50Hz
Capacity
kW
40
45
50
Cooling (*1)
RT
11.4
12.9
14.3
13.2
14.8
3.4
3.38
kW
45
50
56
RT
12.9
14.3
16.0
Input
kW
11.20
12.8
14.4
COP
kW/kW
4.02
3.91
3.89
%
50-130%
50-130%
50-130%
23
26
29
dB(A)
61
62
62
Liquid side
mm
Ф15.9
Ф15.9
Ф19.1
Gas side
mm
Ф31.8
Ф31.8
Ф31.8
Ф6.4
Oil balance pipe
mm
Ф6.4
Ф6.4
Ф6.4
1+1
Quantities
1+1
1+1
2
Type
DC
DC
31.59 +11.80
Btu/h
107800
107800
107800+40300
Input
W
10340
10340
10340+3665
Crankcase
W
27.6×2
27.6×2
27.6×2×2
Type
FVC68D
FVC68D
FVC68D
Input
EER
Capacity
Heating (*2)
Coneectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Pipe connections
DC
DC
DC
Btu/h(W)
31.59 +11.80
31.59 +11.80
31.590 +31.59
Btu/h
107800+40300
107800+40300
107800+107800
Input
W
10340+3665
10340+3665
10340 +10340
Crankcase
W
27.6×2×2
27.6×2×2
27.6×2×2
Type
FVC68D
FVC68D
FVC68D
ml
500+1200
500+1200
500 + 500
DC motor
DC motor
DC motor
2
2
2
CFM
9200
9200
9200
3
m /h
15620
15620
15620
Output
W
390×2(rated)
390×2(rated)
565×2
ESP.
pa
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
Capacity
Compressor
Refrigerant oil
500
500
500+1200
DC motor
DC motor
DC motor
1
1
2
CFM
6620
6620
7660
m3/h
11242
11242
13000
Output
W
450(rated)
450(rated)
230×2(rated)
ESP.
pa
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
0-20 (Default)
20-40 (Customize)
Dimension(W×H×D)
mm
960×1615×765
960×1615×765
1250×1615×765
Dimension(W×H×D)
mm
1250×1615×765
1250×1615×765
1250×1615×765
Packing(W×H×D)
mm
1025×1790×830
1025×1790×830
1305×1790×820
Packing(W×H×D)
mm
1305×1790×820
1305×1790×820
1305×1790×820
Net/Gross weight
kg
202/218
202/218
285/305
Net/Gross weight
kg
285/305
288/308
310/330
R410A
R410A
R410A
R410A
R410A
R410A
9
9
11
kg
13
13
16
EXV
EXV
EXV
Mpa
4.4/2.6
4.4/2.6
4.4/2.6
Cooling
℃
-5~48
-5~48
-5~48
Heating
℃
-20~24
-20~24
-20~24
Quantities
Air flow rate
type
volume
kg
Throttle type
EXV
EXV
EXV
Mpa
4.4/2.6
4.4/2.6
4.4/2.6
Cooling
℃
-5~48
-5~48
-5~48
Heating
℃
-20~24
-20~24
-20~24
Design pressure (High/low)
15
Power supply
3.54
31.59
Type
Ambient temperature range
38VF018H117010
38VF018H118010
11.30
DC
ml
38VF016H117010
38VF016H118010
kW
31.59
Refrigerant oil
Charged refrigerant
1
38VF014H117010
38VF014H118010
Model
kW/kW
Btu/h(W)
Capacity
Fan Motor
Ф6.4
1
Type
Compressor
208/230V 3~60Hz
220V 3~50Hz
kW/kW
EER
Heating (*2)
38VF012H117010
38VF012H118010
Type
Quantities
Fan Motor
Charged refrigerant
Air flow rate
type
volume
Throttle type
Design pressure (High/low)
Ambient temperature range
16
Specifications
Specifications
X-Power Full Inverter Super S Series
X-Power Full Inverter Super S Series
Model
Power supply
Capacity
Cooling (*1)
Input
EER
38VF008H119010
38VF010H119010
38VF012H119010
V-Ph-Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
kW
25.2
28
33.5
RT
7.2
8
9.6
kW
5.88
7.05
8.8
W/W
4.29
3.97
3.81
EER
IPLV
IPLV
5.6
5.7
5.6
W
27
31.5
37.5
RT
7.7
9.0
10.7
Input
W
6.15
7.55
9
COP
W/W
4.39
4.17
4.17
%
50-130%
50-130%
50-130%
13
16
20
dB(A)
57
57
59
mm
Ф12.7
Ф12.7
Ф15.9
Ф25.4
Ф25.4
Ф31.8
Capacity
Heating (*2)
Connectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Liquid side
Gas side
Pipe connections
mm
Ф6.4
Ф6.4
Ф6.4
Max. input consumption
Oil balance pipe
W
11270
11270
16953
Max. current
A
20.8
22.1
30.8
1
1
1+1
DC Inverter
DC Inverter
DC Inverter
Quantities
Type
Compressor
Capacity
W
31590(90HZ)
31590(90HZ)
31590(90HZ)+11800(60HZ)
Input
W
10340(90HZ)
10340(90HZ)
10340(90HZ)+3665(60HZ)
Crankcase
W
40~80
40~80
40~80
FVC68D
FVC68D
FVC68D
500
500
500 + 500
DC Inverter
DC Inverter
DC Inverter
1
1
2
454
454
232×2
0~20 (default)
0~20 (default)
0~20 (default)
20~40 (optional)
20~40(optional)
20~60 (optional)
Oil type
Oil charge
ml
Type
Quantities
Fan Motor
Output
W
ESP
pa
m /h
11242
11242
15620
Dimension(W*H*D)
mm
960×1615×765
960×1615×765
1250×1615×765
Packing (W*H*D)
mm
1025×1790×830
1025×1790×830
1305×1790×820
Net/Gross weight
Kg
212/227
212/227
288/308
kg
R410A 10kg
R410A 10kg
R410A 12kg
EXV
EXV
EXV
MPa
4.4/2.6
4.4/2.6
4.4/2.6
Ambient temp. range - Cooling
℃
-5℃-48℃
-5℃-48℃
-5℃-48℃
Ambient temp. range - Heating
℃
-20℃-27℃
-20℃-27℃
-20℃-27℃
Air flow rate
Outdoor unit
Charged refrigerant type and volume
3
Throttle type
Excessive operating pressure
38VF014H119010
38VF016H119010
38VF018H119010
V-Ph-Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
kW
40
45
50
RT
11.4
12.9
14.3
kW
11.3
13.2
14.8
W/W
3.54
3.4
3.38
Model
Power supply
Capacity
Cooling (*1)
Input
5.5
5.4
5.8
W
45
50
56
RT
12.9
14.3
16.0
Input
W
11.2
12.8
14.4
COP
W/W
4.02
3.91
3.89
%
50-130%
50-130%
50-130%
23
26
29
dB(A)
61
62
62
mm
Ф15.9
Ф15.9
Ф19.1
Ф31.8
Ф31.8
Ф31.8
Capacity
Heating (*2)
Connectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Liquid side
Pipe connections
Gas side
mm
Ф6.4
Ф6.4
Ф6.4
Max. input consumption
Oil balance pipe
W
16953
17402
27250
Max. current
A
31.8
32.8
46
1+1
1+1
1+1
DC Inverter
DC Inverter
DC Inverter
Quantities
Type
Compressor
Capacity
W
31590(90HZ)+11800(60HZ)
31590(90HZ)+11800(60HZ)
31590(90Hz)+31590(90Hz)
Input
W
10340(90HZ)+3665(60HZ)
10340(90HZ)+3665(60HZ)
10340(90Hz)+10340(90Hz)
Crankcase
W
40~80
40~80
FVC68D
FVC68D
FVC68D
500 + 500
500 + 500
500 + 500
DC MOTOR
DC MOTOR
DC MOTOR
2
2
2
383×2
383×2
560×2
0~20 (default)
0~20 (default)
0~20 (default)
20~40 (optional)
20~40 (optional)
20~40 (optional)
Oil type
Oil charge
ml
Type
Quantities
Fan Motor
Output
W
ESP
pa
27.6×2
m /h
15620
15620
15770
Dimension(W*H*D)
mm
1250×1615×765
1250×1615×765
1250*1615*765
Packing (W*H*D)
mm
1305×1790×820
1305×1790×820
1305×1790×820
Net/Gross weight
Kg
288/308
288/308
310/330
kg
R410A 15kg
R410A 15kg
R410A 16kg
EXV
EXV
EXV
MPa
4.4/2.6
4.4/2.6
4.4/2.6
Ambient temp. range - Cooling
℃
-5℃-48℃
-5℃-48℃
-5℃-48℃
Ambient temp. range - Heating
℃
-20℃-27℃
-20℃-27℃
-20℃-27℃
Air flow rate
Outdoor unit
Charged refrigerant type and volume
3
Throttle type
Excessive operating pressure
Note: 18HP is not the standard model, need to customize
17
18
Specifications
Specifications
X-Power Full Inverter Super S Series
X-Power Full Inverter Super S Series
Model
Power supply
Capacity
Cooling (*1)
Input
EER
38VF008H119010
38VF010H119010
38VF012H119010
V-Ph-Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
kW
25.2
28
33.5
RT
7.2
8
9.6
kW
5.88
7.05
8.8
W/W
4.29
3.97
3.81
EER
IPLV
IPLV
5.6
5.7
5.6
W
27
31.5
37.5
RT
7.7
9.0
10.7
Input
W
6.15
7.55
9
COP
W/W
4.39
4.17
4.17
%
50-130%
50-130%
50-130%
13
16
20
dB(A)
57
57
59
mm
Ф12.7
Ф12.7
Ф15.9
Ф25.4
Ф25.4
Ф31.8
Capacity
Heating (*2)
Connectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Liquid side
Gas side
Pipe connections
mm
Ф6.4
Ф6.4
Ф6.4
Max. input consumption
Oil balance pipe
W
11270
11270
16953
Max. current
A
20.8
22.1
30.8
1
1
1+1
DC Inverter
DC Inverter
DC Inverter
Quantities
Type
Compressor
Capacity
W
31590(90HZ)
31590(90HZ)
31590(90HZ)+11800(60HZ)
Input
W
10340(90HZ)
10340(90HZ)
10340(90HZ)+3665(60HZ)
Crankcase
W
40~80
40~80
40~80
FVC68D
FVC68D
FVC68D
500
500
500 + 500
DC Inverter
DC Inverter
DC Inverter
1
1
2
454
454
232×2
0~20 (default)
0~20 (default)
0~20 (default)
20~40 (optional)
20~40(optional)
20~60 (optional)
Oil type
Oil charge
ml
Type
Quantities
Fan Motor
Output
W
ESP
pa
m /h
11242
11242
15620
Dimension(W*H*D)
mm
960×1615×765
960×1615×765
1250×1615×765
Packing (W*H*D)
mm
1025×1790×830
1025×1790×830
1305×1790×820
Net/Gross weight
Kg
212/227
212/227
288/308
kg
R410A 10kg
R410A 10kg
R410A 12kg
EXV
EXV
EXV
MPa
4.4/2.6
4.4/2.6
4.4/2.6
Ambient temp. range - Cooling
℃
-5℃-48℃
-5℃-48℃
-5℃-48℃
Ambient temp. range - Heating
℃
-20℃-27℃
-20℃-27℃
-20℃-27℃
Air flow rate
Outdoor unit
Charged refrigerant type and volume
3
Throttle type
Excessive operating pressure
38VF014H119010
38VF016H119010
38VF018H119010
V-Ph-Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
380~415V 3Ph ~ 50/60Hz
kW
40
45
50
RT
11.4
12.9
14.3
kW
11.3
13.2
14.8
W/W
3.54
3.4
3.38
Model
Power supply
Capacity
Cooling (*1)
Input
5.5
5.4
5.8
W
45
50
56
RT
12.9
14.3
16.0
Input
W
11.2
12.8
14.4
COP
W/W
4.02
3.91
3.89
%
50-130%
50-130%
50-130%
23
26
29
dB(A)
61
62
62
mm
Ф15.9
Ф15.9
Ф19.1
Ф31.8
Ф31.8
Ф31.8
Capacity
Heating (*2)
Connectable indoor unit
Total capacity
Max.quantity
Outdoor sound level (*3)
Liquid side
Pipe connections
Gas side
mm
Ф6.4
Ф6.4
Ф6.4
Max. input consumption
Oil balance pipe
W
16953
17402
27250
Max. current
A
31.8
32.8
46
1+1
1+1
1+1
DC Inverter
DC Inverter
DC Inverter
Quantities
Type
Compressor
Capacity
W
31590(90HZ)+11800(60HZ)
31590(90HZ)+11800(60HZ)
31590(90Hz)+31590(90Hz)
Input
W
10340(90HZ)+3665(60HZ)
10340(90HZ)+3665(60HZ)
10340(90Hz)+10340(90Hz)
Crankcase
W
40~80
40~80
FVC68D
FVC68D
FVC68D
500 + 500
500 + 500
500 + 500
DC MOTOR
DC MOTOR
DC MOTOR
2
2
2
383×2
383×2
560×2
0~20 (default)
0~20 (default)
0~20 (default)
20~40 (optional)
20~40 (optional)
20~40 (optional)
Oil type
Oil charge
ml
Type
Quantities
Fan Motor
Output
W
ESP
pa
27.6×2
m /h
15620
15620
15770
Dimension(W*H*D)
mm
1250×1615×765
1250×1615×765
1250*1615*765
Packing (W*H*D)
mm
1305×1790×820
1305×1790×820
1305×1790×820
Net/Gross weight
Kg
288/308
288/308
310/330
kg
R410A 15kg
R410A 15kg
R410A 16kg
EXV
EXV
EXV
MPa
4.4/2.6
4.4/2.6
4.4/2.6
Ambient temp. range - Cooling
℃
-5℃-48℃
-5℃-48℃
-5℃-48℃
Ambient temp. range - Heating
℃
-20℃-27℃
-20℃-27℃
-20℃-27℃
Air flow rate
Outdoor unit
Charged refrigerant type and volume
3
Throttle type
Excessive operating pressure
Note: 18HP is not the standard model, need to customize
17
18
Dimensions
Body dimension
Unit: in.(mm)
63-9/16(1615)
12/14/16 /18 HP
63-9/16(1615)
8/10 HP
37-25/32(960)
X-Power Full DC Inverter
Mini H Series
30-1/8(765)
30-1/8(765)
49-7/32(1250)
Installation dimension
Unit: in.(mm)
Screw bolt position
8/10HP: 37-51/64(960)
12/14/16HP:49-7/32(1250)
8/10HP: 32-43/64(830)
12/14/16HP:44-3/32(1120)
Solid ground
or roofing
Concrete
basement
h=7-7/8(200)
7-7/8(200)
30-1/8(765)
Rubber shocking
proof mat
28-31/32(736)
Φ25/64(10)
Expansion bolt
15×23long U-shape hole
NEW
Fashion
Design
19
20
Dimensions
Body dimension
Unit: in.(mm)
63-9/16(1615)
12/14/16 /18 HP
63-9/16(1615)
8/10 HP
37-25/32(960)
X-Power Full DC Inverter
Mini H Series
30-1/8(765)
30-1/8(765)
49-7/32(1250)
Installation dimension
Unit: in.(mm)
Screw bolt position
8/10HP: 37-51/64(960)
12/14/16HP:49-7/32(1250)
8/10HP: 32-43/64(830)
12/14/16HP:44-3/32(1120)
Solid ground
or roofing
Concrete
basement
h=7-7/8(200)
7-7/8(200)
30-1/8(765)
Rubber shocking
proof mat
28-31/32(736)
Φ25/64(10)
Expansion bolt
15×23long U-shape hole
NEW
Fashion
Design
19
20
Flexible piping design
Features
12kW; 14kW; 16kW
(40,900Btu/h; 47,800Btu/h; 52,900Btu/h)
20kW; 22.4kW; 26kW
(68.240Btu/h; 76,430Btu/h; 88,700Btu/h)
40kW; 50kW
(136,480Btu/h; 153,540Btu/h)
The longest piping length is 70m(229.7ft)
8kW; 10.5kW
(27,300Btu/h;35,830Btu/h)
The first branch joint to the
farthest IDU is 20m(65.6ft)
The outdoor units’ capacity range from 8kW(27,300Btu/h) to 45kW(153,540Btu/h) which is ideal for small
offices, villas, apartment and shops, making it perfect for commercial and residential application.
The IDU to the nearest
branch joint is 15m(49.2ft)
Wide range of outdoor units
Level difference between IDUs is 8m(26.2ft)
Wide Application Range
Level difference between IDU and ODU is 30m(98.4ft)
The Mini VRF provides a total piping length possibility of 100m(328ft), a maximum height difference
between outdoor and indoor units of 30m(98.4ft). The height difference between indoors unit can be up to
8m(26.2ft). These generous allowances facilitate an extensive array of system designs.
Max. 7 indoor units for a 16kW(52,900Btu/h) outdoor unit installation
Max. 6 indoor units for a 14kW(47,800Btu/h) outdoor unit installation
Max. 6 indoor units for a 12kW(40,900Btu/h) outdoor unit installation
Max. 5 indoor units for a 10.5kW(35,800Btu/h) outdoor unit installation
3.92
40,900
3.54
47,800
COOLING MODE
New design
27°C
(80.6°F)
20
68
*For 20-45KW unit, please check the information in the following specifications.
21
50m(164ft)
70m(229.7ft)
20m(65.6ft)
20m(65.6ft)
30m(98.4ft)
30m(98.4ft)
Outdoor unit down 20m(65.6ft)
20m(65.6ft)
8m(26.2ft)
8m(26.2ft)
Level difference
between IDU~ODU
Outdoor unit up
Level difference between IDU~IDU
3.97
35,800
3.8
40,900
3.7
47,800
3.56
52,900 Btu/h
43°C
(118.4°F)
HEATING MODE
10
50
Equivalent length
Equivalent piping length (from the
farthest IDU to the first indoor branch
jointC)
*For 20-45KW unit, please check the information in the specifications.
Reduce air resistance
0
32
Level difference
52,900 Btu/h
Mini VRF system operates stably at extreme temperature range from minus 15°C (5°F) to 43°C(118.4°F).
-10
14
60m(196.9ft)
Actual length
Longest piping (L)
3.43
High performance heat exchanger
-20
-4
45m(146.7ft)
Piping length
COP
3.78
Wide operation temperature range
-15°C
(5°F)
100m(328ft)
High COP and EER values
35,800
-15°C
(5°F)
100m(328ft)
High Efficiency
EER
* For 20-45KW unit, please check the information in the specifications.
Total piping length (Actual)
1 Total pipe length is equal to all the liquid pipe or all the gas pipe length.
2 When the total equivalent pipe length of liquid side plus gas side is more than 90m(295.2ft),
it needs to meet the specific conditions according to the installation part of the technical manual.
3 *For 20-45KW unit, please check the information in the specifications.
Flexible indoor units connection
Mini VRF with intelligent control gives you independent zoning control with maximum flexibility.
A single outdoor unit supports up to nine indoor units, freeing up considerable space outside. Use your backyard
more wisely with much more space available created by less number of outdoor units.
10.5kW
12/14/16kW
(35,800Btu/h) (40,900/47,800//52,900Btu/h)
Permitted value
30
86
40
104
50 °C(D.B.)
122 °F(D.B.)
Outdoor temp.
Original design
High efficiency inner-threaded pipe,
enhance heat transfer.
Hydrophilic fins + inner-threaded pipes
The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more
power and enhance heat exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
The specially coated blue fins enhance durability and protect against corrosion from air, water and other
corrosive agents, assures a longer coil service life.
22
Flexible piping design
Features
12kW; 14kW; 16kW
(40,900Btu/h; 47,800Btu/h; 52,900Btu/h)
20kW; 22.4kW; 26kW
(68.240Btu/h; 76,430Btu/h; 88,700Btu/h)
40kW; 50kW
(136,480Btu/h; 153,540Btu/h)
The longest piping length is 70m(229.7ft)
8kW; 10.5kW
(27,300Btu/h;35,830Btu/h)
The first branch joint to the
farthest IDU is 20m(65.6ft)
The outdoor units’ capacity range from 8kW(27,300Btu/h) to 45kW(153,540Btu/h) which is ideal for small
offices, villas, apartment and shops, making it perfect for commercial and residential application.
The IDU to the nearest
branch joint is 15m(49.2ft)
Wide range of outdoor units
Level difference between IDUs is 8m(26.2ft)
Wide Application Range
Level difference between IDU and ODU is 30m(98.4ft)
The Mini VRF provides a total piping length possibility of 100m(328ft), a maximum height difference
between outdoor and indoor units of 30m(98.4ft). The height difference between indoors unit can be up to
8m(26.2ft). These generous allowances facilitate an extensive array of system designs.
Max. 7 indoor units for a 16kW(52,900Btu/h) outdoor unit installation
Max. 6 indoor units for a 14kW(47,800Btu/h) outdoor unit installation
Max. 6 indoor units for a 12kW(40,900Btu/h) outdoor unit installation
Max. 5 indoor units for a 10.5kW(35,800Btu/h) outdoor unit installation
3.92
40,900
3.54
47,800
COOLING MODE
New design
27°C
(80.6°F)
20
68
*For 20-45KW unit, please check the information in the following specifications.
21
50m(164ft)
70m(229.7ft)
20m(65.6ft)
20m(65.6ft)
30m(98.4ft)
30m(98.4ft)
Outdoor unit down 20m(65.6ft)
20m(65.6ft)
8m(26.2ft)
8m(26.2ft)
Level difference
between IDU~ODU
Outdoor unit up
Level difference between IDU~IDU
3.97
35,800
3.8
40,900
3.7
47,800
3.56
52,900 Btu/h
43°C
(118.4°F)
HEATING MODE
10
50
Equivalent length
Equivalent piping length (from the
farthest IDU to the first indoor branch
jointC)
*For 20-45KW unit, please check the information in the specifications.
Reduce air resistance
0
32
Level difference
52,900 Btu/h
Mini VRF system operates stably at extreme temperature range from minus 15°C (5°F) to 43°C(118.4°F).
-10
14
60m(196.9ft)
Actual length
Longest piping (L)
3.43
High performance heat exchanger
-20
-4
45m(146.7ft)
Piping length
COP
3.78
Wide operation temperature range
-15°C
(5°F)
100m(328ft)
High COP and EER values
35,800
-15°C
(5°F)
100m(328ft)
High Efficiency
EER
* For 20-45KW unit, please check the information in the specifications.
Total piping length (Actual)
1 Total pipe length is equal to all the liquid pipe or all the gas pipe length.
2 When the total equivalent pipe length of liquid side plus gas side is more than 90m(295.2ft),
it needs to meet the specific conditions according to the installation part of the technical manual.
3 *For 20-45KW unit, please check the information in the specifications.
Flexible indoor units connection
Mini VRF with intelligent control gives you independent zoning control with maximum flexibility.
A single outdoor unit supports up to nine indoor units, freeing up considerable space outside. Use your backyard
more wisely with much more space available created by less number of outdoor units.
10.5kW
12/14/16kW
(35,800Btu/h) (40,900/47,800//52,900Btu/h)
Permitted value
30
86
40
104
50 °C(D.B.)
122 °F(D.B.)
Outdoor temp.
Original design
High efficiency inner-threaded pipe,
enhance heat transfer.
Hydrophilic fins + inner-threaded pipes
The new designed window fins enlarge the heat-exchanging area , decrease the air resistance, save more
power and enhance heat exchange performance.
Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency.
The specially coated blue fins enhance durability and protect against corrosion from air, water and other
corrosive agents, assures a longer coil service life.
22
Easier Installation and Service
More convenience in installation
Easy installation
Easy to transport
A four-direction space is available for connecting pipes and wiring in
various installation sites.
No need special room for the outdoor units.
Easy installation: No special area is required for outdoor
Front side
Right side
Back side
Bottom side
Back side
units.
Easy transportation: All outdoor units can be transported
by elevator, which greatly simplifies installation and
Right side
reduces time and labor.
Front side
The Mini VRF system's indoor and outdoor units are
almost as easy to install as residential air
conditioning systems, making them ideal for small offices
and shops.
Bottom side
More convenient piping connector - branch box
Easier and safer installation thanks to a branch box that simplifies piping work and the adoption of screw
connection.
Both left and right pipe flare connection from outdoor unit to branch box is reserved, which greatly simplifies
field installation.
Space saving design
The Mini VRF units are slimmer and more compact, resulting in significant savings in installation space.
In some large residential and light commercial areas, such as villas, restaurants, usually it need more than
one indoor unit, which in turn requires multiple outdoor units.
Carrier's MINI VRF system removes this problem, and retains buildings' original aesthetics.
Two sets of pipe size converter are packed with branch box to transfer the pipe size from Φ6.35mm(Φ1/4in) to
Φ9.53mm(Φ3/8in) and from Φ12.7mm(Φ1/2in) to Φ15.9mm(Φ5/8in).
Low noise
The branch pipe is linear expansion design regulates the flow of
refrigerant and reduces the noise. By locating the branch box in the
ceiling or outside ,noise generated by the branch box can be kept
clear of living spaces, thus makes noise level to a minimum.
Brazing-free quick installation
All the piping leading to and from the branch box is connected using screw joints,which can be
installed quickly and easily.
Indoor installation
The branch box can be installed in the ceiling rather than outside. Removing the side and
bottom covers provides easy access for maintaining inner components such as circuit boards.
New piping connection design
Auto addressing
Addresses of indoor units can be set automatically by outdoor units.
Wireless controller can inquire and modify every indoor units address.
Outdoor unit can
distribute address
for indoor unit.
Shield signal wire
WR-29B-CM
23
WL-12-CM
*40/45KW unit can not connect branch box
24
Easier Installation and Service
More convenience in installation
Easy installation
Easy to transport
A four-direction space is available for connecting pipes and wiring in
various installation sites.
No need special room for the outdoor units.
Easy installation: No special area is required for outdoor
Front side
Right side
Back side
Bottom side
Back side
units.
Easy transportation: All outdoor units can be transported
by elevator, which greatly simplifies installation and
Right side
reduces time and labor.
Front side
The Mini VRF system's indoor and outdoor units are
almost as easy to install as residential air
conditioning systems, making them ideal for small offices
and shops.
Bottom side
More convenient piping connector - branch box
Easier and safer installation thanks to a branch box that simplifies piping work and the adoption of screw
connection.
Both left and right pipe flare connection from outdoor unit to branch box is reserved, which greatly simplifies
field installation.
Space saving design
The Mini VRF units are slimmer and more compact, resulting in significant savings in installation space.
In some large residential and light commercial areas, such as villas, restaurants, usually it need more than
one indoor unit, which in turn requires multiple outdoor units.
Carrier's MINI VRF system removes this problem, and retains buildings' original aesthetics.
Two sets of pipe size converter are packed with branch box to transfer the pipe size from Φ6.35mm(Φ1/4in) to
Φ9.53mm(Φ3/8in) and from Φ12.7mm(Φ1/2in) to Φ15.9mm(Φ5/8in).
Low noise
The branch pipe is linear expansion design regulates the flow of
refrigerant and reduces the noise. By locating the branch box in the
ceiling or outside ,noise generated by the branch box can be kept
clear of living spaces, thus makes noise level to a minimum.
Brazing-free quick installation
All the piping leading to and from the branch box is connected using screw joints,which can be
installed quickly and easily.
Indoor installation
The branch box can be installed in the ceiling rather than outside. Removing the side and
bottom covers provides easy access for maintaining inner components such as circuit boards.
New piping connection design
Auto addressing
Addresses of indoor units can be set automatically by outdoor units.
Wireless controller can inquire and modify every indoor units address.
Outdoor unit can
distribute address
for indoor unit.
Shield signal wire
WR-29B-CM
23
WL-12-CM
*40/45KW unit can not connect branch box
24
Advanced Technologies
Outdoor Unit
Full DC inverter technology
At the heart of our system is a highly intelligent inverter driven compressor. This advanced technology
enables the output of the outdoor unit to be modulated by the cooling or heating demands of the zone that
it controls. This advanced system ensures precise temperature regulation and highly efficient energy
usage, making a significant contribution to the limiting the impact on the environment.
380/415V~3Ph~60Hz
380/415V~3Ph~50Hz
38VR004H118010
38VR005H118010
38VR006H118010
38VR004H119010
38VR005H119010
38VR006H119010
38VR007H119010
38VR008H11901S
38VR010H11901S
38VR014H11901S
38VR016H11901S
Specifications 60Hz&50Hz
Highly Efficient DC Motor:
- Creative motor core design
Sales Model
- High density neodymium magnet
- Concentrated type stator
Power supply
-Wider operating frequency range
Cooling
- Twin eccentric cams
- 2 balance weights
Highly Stable Moving Parts:
Heating
-Optimize compressor drive technology
- Highly robust bearings
Pipe
connections
Motor speed(RPM)
High efficiency DC fan motor saved power up to 50%.
Connectable
DC inverter stepless
adjustment
AC inverter
multistep adjustment
Compressor
System pressure
Optimally designed fan shape and air discharge grille increases air volume and reduces running noise.
14
15.5
4.4
Input
kW
3.25
3.95
4.52
EER
kW/ kW
3.69
3.54
3.43
kW
13.2
15.4
17
RT
3.8
4.4
4.9
Input
kW
3.47
4.16
4.77
COP
kW/ kW
3.8
3.7
3.56
dB(A)
57
57
57
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф19.1
%
50-130%
50-130%
50-130%
6
6
7
Type
Rotary
Rotary
Rotary
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
Total capacity
Max.quantity
Capacity
kW
9.88
9.88
13.98
Crankcase
W
27
27
25
Refrigerant oil
Type
FV50S
FV50S
FV50S
Refrigerant oil
ml
870
870
1400
DC motor
DC motor
DC motor
2
2
2
2 x85
2 x85
2 x 85
Output
Outdoor unit
CFM
4100
3824
3530
6983
6500
6000
Dimension(W x H x D)
mm
900 x 1327 x 400
900 x 1327 x 400
900 x 1327 x 400
Packing (W x H x D)
mm
1030 x 1456 x 435
1030 x 1456 x 435
1030 x 1456 x 435
Net/Gross weight
New grille
Refrigerant
W
m3/h
Airflow
Air deflector
kg
Type
Charged volume
g
Throttle type
Design pressure
New fan
Ambient temp
Newly Designed Fan Guard
25
Powerful Large Propeller
380-415V-3Ph~60Hz
4.0
Quantity
Fan Motor
380-415V-3Ph~60Hz
12
Type
Noise reducing design
380-415V-3Ph~60Hz
3.4
Outdoor sound level (*3)
-Compact structure
38VR006H118010
RT
Capacity
- Optimal material matching rollers and vanes
38VR005H118010
kW
Capacity
Better balance and Extremely Low Vibration:
Compressor
(Twin Rotary) structure
V-Ph-Hz
38VR004H118010
92/106
95/106
102/113
R410A
R410A
R410A
3300
3900
3900
EXV
MPa
℉(℃)
4.4/2.6
15~43℃
-15~27℃
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6 °F), 19 °C WB(60°F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°F), 15°C WB(44.6°F) outdoor temp.: 7 °C DB(42.8°F) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m(3.28ft) in front of the unit at a height of *m( 1m(3.28ft) for 105 model,1.2m(3.94ft) for 120~160model). During
actual operation, these values might be higher as a result of ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
26
Advanced Technologies
Outdoor Unit
Full DC inverter technology
At the heart of our system is a highly intelligent inverter driven compressor. This advanced technology
enables the output of the outdoor unit to be modulated by the cooling or heating demands of the zone that
it controls. This advanced system ensures precise temperature regulation and highly efficient energy
usage, making a significant contribution to the limiting the impact on the environment.
380/415V~3Ph~60Hz
380/415V~3Ph~50Hz
38VR004H118010
38VR005H118010
38VR006H118010
38VR004H119010
38VR005H119010
38VR006H119010
38VR007H119010
38VR008H11901S
38VR010H11901S
38VR014H11901S
38VR016H11901S
Specifications 60Hz&50Hz
Highly Efficient DC Motor:
- Creative motor core design
Sales Model
- High density neodymium magnet
- Concentrated type stator
Power supply
-Wider operating frequency range
Cooling
- Twin eccentric cams
- 2 balance weights
Highly Stable Moving Parts:
Heating
-Optimize compressor drive technology
- Highly robust bearings
Pipe
connections
Motor speed(RPM)
High efficiency DC fan motor saved power up to 50%.
Connectable
DC inverter stepless
adjustment
AC inverter
multistep adjustment
Compressor
System pressure
Optimally designed fan shape and air discharge grille increases air volume and reduces running noise.
14
15.5
4.4
Input
kW
3.25
3.95
4.52
EER
kW/ kW
3.69
3.54
3.43
kW
13.2
15.4
17
RT
3.8
4.4
4.9
Input
kW
3.47
4.16
4.77
COP
kW/ kW
3.8
3.7
3.56
dB(A)
57
57
57
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф19.1
%
50-130%
50-130%
50-130%
6
6
7
Type
Rotary
Rotary
Rotary
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
Total capacity
Max.quantity
Capacity
kW
9.88
9.88
13.98
Crankcase
W
27
27
25
Refrigerant oil
Type
FV50S
FV50S
FV50S
Refrigerant oil
ml
870
870
1400
DC motor
DC motor
DC motor
2
2
2
2 x85
2 x85
2 x 85
Output
Outdoor unit
CFM
4100
3824
3530
6983
6500
6000
Dimension(W x H x D)
mm
900 x 1327 x 400
900 x 1327 x 400
900 x 1327 x 400
Packing (W x H x D)
mm
1030 x 1456 x 435
1030 x 1456 x 435
1030 x 1456 x 435
Net/Gross weight
New grille
Refrigerant
W
m3/h
Airflow
Air deflector
kg
Type
Charged volume
g
Throttle type
Design pressure
New fan
Ambient temp
Newly Designed Fan Guard
25
Powerful Large Propeller
380-415V-3Ph~60Hz
4.0
Quantity
Fan Motor
380-415V-3Ph~60Hz
12
Type
Noise reducing design
380-415V-3Ph~60Hz
3.4
Outdoor sound level (*3)
-Compact structure
38VR006H118010
RT
Capacity
- Optimal material matching rollers and vanes
38VR005H118010
kW
Capacity
Better balance and Extremely Low Vibration:
Compressor
(Twin Rotary) structure
V-Ph-Hz
38VR004H118010
92/106
95/106
102/113
R410A
R410A
R410A
3300
3900
3900
EXV
MPa
℉(℃)
4.4/2.6
15~43℃
-15~27℃
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6 °F), 19 °C WB(60°F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°F), 15°C WB(44.6°F) outdoor temp.: 7 °C DB(42.8°F) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m(3.28ft) in front of the unit at a height of *m( 1m(3.28ft) for 105 model,1.2m(3.94ft) for 120~160model). During
actual operation, these values might be higher as a result of ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
26
DC inverter MINI H series-3p
Specifications 50Hz
Specifications 50Hz
Sale Model
Power supply
V-Ph-Hz
Power supply
38VR016H11901S
V-Ph-Hz
380-415V-3N~50Hz
380-415V-3N~50Hz
380-415V-3N~50Hz
380-415-3N~50
380-415-3N~50
kW
20
22.4
26
40
45
RT
5.7
6.4
7.4
11.4
12.9
4.4
kW
3.9
4.75
5.6
Input
kW
6.63
7.2
8.4
11.9
13.6
3.08
2.95
2.77
EER
KW/KW
3.02
3.11
3.09
3.35
3.32
kW
13.2
15.4
17
kW
22
24.5
28.5
45
50
RT
3.8
4.4
4.9
RT
6.29
7
8.1
12.86
14.3
kW
3.75
4.55
5.4
Input
kW
5.95
6.7
7.9
11.1
12.7
3.52
3.38
3.15
COP
KW/KW
3.69
3.66
3.6
4.05
3.93
50-130%
50-130%
50-130%
dB(A)
59
59
60
62
62
6
6
7
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф12.7
Ф12.7
dB(A)
57
57
57
Gas side
mm
Ф19.1
Ф19.1
Ф22.2
Ф22.2
Ф25.4
Liquid side
mm
Ф9.52
Ф9.52
Ф9.52
%
50-130%
50-130%
50-130%
50-130%
50-130%
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
10
11
12
14
15
Type
Rotary
Rotary
Rotary
Type
Rotary
Rotary
Rotary
Rotary
Rotary
MITSUBISHI
MITSUBISHI
MITSUBISHI
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
Brand
MITSUBISHI
MITSUBISHI
Btu/h
16860×2
33720
47700
16860
13980×2
33720
13980
16860
Btu/h
W
25×2
27
27
25
25
25×2
W
25
25
Crankcase
FV50S
FV50S
FV50S
FV50S
FV50S
ml
FV50S 870ml
FV50S 870ml
FV50S 1400ml
Refrigerant oil
Type
Refrigerant oil
Refrigerant oil
ml
1400+1300
1700+1500
1700+1500
1400×2+2500
1700×2+3600
2
2
2
DC motor
DC motor
DC motor
DC+AC
DC+AC
DC motor
DC motor
DC motor
2
2
2
1+1
1+1
m3/h
6000
6000
6000
W
210/160
200/150
200/150
560/320
560/320
CFM
3529
3529
3529
CFM
6470
6173
6173
9750
9750
Dimension(W*H*D)
mm
900*1327*320
900*1327*320
900*1327*320
m³/h
10999
10494
10494
16575
16575
Packing (W*H*D)
mm
1030*1456*435
1030*1456*435
1030*1456*435
mm
1120×1558×400
1120×1558×400
1120×1558×400
1360×1650×540
1460×1650×540
Net/Gross weight
kg
95/106
95/106
102/113
kg
137/153
146.5/162.5
147/163
240/260
275/290
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
3300
3900
3900
4800
6200
6200
9000
12000
EXV
EXV
EXV
4.4/2.6
4.4/2.6
4.4/2.6
Cooling -15~43
Cooling -15~43
Cooling -15~43
Heating -15~27
Heating -15~27
Heating -15~27
COP
Total capacity
%
Max.quantity
Outdoor sound level
(sound pressure level )
Capacity
Quantities
Type
Air flow rate
Type
Charged volume
g
Throttle type
Design pressure
MPa
℃
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6 °F), 19 °C WB(60°F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°F), 15°C WB(44.6°F) outdoor temp.: 7 °C DB(42.8°F) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m(3.28ft) in front of the unit at a height of *m( 1m(3.28ft) for 105 model,1.2m(3.94ft) for 120~160model). During
actual operation, sound level might be affected by ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
27
38VR014H11901S
4.0
Input
Ambient temp
380-415V-3N~50Hz
38VR010H11901S
3.4
Heating
Refrigerant
380-415V-3N~50Hz
38VR008H11901S
RT
Capacity
Outdoor unit
380-415V-3N~50Hz
38VR007H119010
15.5
EER
Fan motor
Sales Model
14
Input
Compressor
38VR006H119010
12
Cooling
Refrigerant
Pipe
38VR005H119010
kW
Capacity
Coneectable
indoor unit
38VR004H119010
Capacity
Cooling
Capacity
Heating
Outdoor sound level(*3)
Pipe
connections
Connectable
Compressor
Total capacity
Max.quantity
Capacity
Crankcase
Type
Quantity
Fan Motor
Output
Airflow
Outdoor unit
Dimension(W x H x D)
Net/Gross weight
Refrigerant
Type
Charged volume
g
EXV
Throttle type
Design pressure
Ambient temp
4.4/2.6
MPa
°F(°C)
-5~48
-5~48
-5~48
-5~48
-5~48
-15~27
-15~27
-15~27
-15~24
-15~24
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6 °F), 19 °C WB(60°F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°F), 15°C WB(44.6°F) outdoor temp.: 7 °C DB(42.8°F) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m(3.28ft) in front of the unit at a height of *m( 1m(3.28ft) for 105 model,1.2m(3.94ft) for 120~160model). During
actual operation, sound level might be affected by ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
28
DC inverter MINI H series-3p
Specifications 50Hz
Specifications 50Hz
Sale Model
Power supply
V-Ph-Hz
Power supply
38VR016H11901S
V-Ph-Hz
380-415V-3N~50Hz
380-415V-3N~50Hz
380-415V-3N~50Hz
380-415-3N~50
380-415-3N~50
kW
20
22.4
26
40
45
RT
5.7
6.4
7.4
11.4
12.9
4.4
kW
3.9
4.75
5.6
Input
kW
6.63
7.2
8.4
11.9
13.6
3.08
2.95
2.77
EER
KW/KW
3.02
3.11
3.09
3.35
3.32
kW
13.2
15.4
17
kW
22
24.5
28.5
45
50
RT
3.8
4.4
4.9
RT
6.29
7
8.1
12.86
14.3
kW
3.75
4.55
5.4
Input
kW
5.95
6.7
7.9
11.1
12.7
3.52
3.38
3.15
COP
KW/KW
3.69
3.66
3.6
4.05
3.93
50-130%
50-130%
50-130%
dB(A)
59
59
60
62
62
6
6
7
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф12.7
Ф12.7
dB(A)
57
57
57
Gas side
mm
Ф19.1
Ф19.1
Ф22.2
Ф22.2
Ф25.4
Liquid side
mm
Ф9.52
Ф9.52
Ф9.52
%
50-130%
50-130%
50-130%
50-130%
50-130%
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
10
11
12
14
15
Type
Rotary
Rotary
Rotary
Type
Rotary
Rotary
Rotary
Rotary
Rotary
MITSUBISHI
MITSUBISHI
MITSUBISHI
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
Brand
MITSUBISHI
MITSUBISHI
Btu/h
16860×2
33720
47700
16860
13980×2
33720
13980
16860
Btu/h
W
25×2
27
27
25
25
25×2
W
25
25
Crankcase
FV50S
FV50S
FV50S
FV50S
FV50S
ml
FV50S 870ml
FV50S 870ml
FV50S 1400ml
Refrigerant oil
Type
Refrigerant oil
Refrigerant oil
ml
1400+1300
1700+1500
1700+1500
1400×2+2500
1700×2+3600
2
2
2
DC motor
DC motor
DC motor
DC+AC
DC+AC
DC motor
DC motor
DC motor
2
2
2
1+1
1+1
m3/h
6000
6000
6000
W
210/160
200/150
200/150
560/320
560/320
CFM
3529
3529
3529
CFM
6470
6173
6173
9750
9750
Dimension(W*H*D)
mm
900*1327*320
900*1327*320
900*1327*320
m³/h
10999
10494
10494
16575
16575
Packing (W*H*D)
mm
1030*1456*435
1030*1456*435
1030*1456*435
mm
1120×1558×400
1120×1558×400
1120×1558×400
1360×1650×540
1460×1650×540
Net/Gross weight
kg
95/106
95/106
102/113
kg
137/153
146.5/162.5
147/163
240/260
275/290
R410A
R410A
R410A
R410A
R410A
R410A
R410A
R410A
3300
3900
3900
4800
6200
6200
9000
12000
EXV
EXV
EXV
4.4/2.6
4.4/2.6
4.4/2.6
Cooling -15~43
Cooling -15~43
Cooling -15~43
Heating -15~27
Heating -15~27
Heating -15~27
COP
Total capacity
%
Max.quantity
Outdoor sound level
(sound pressure level )
Capacity
Quantities
Type
Air flow rate
Type
Charged volume
g
Throttle type
Design pressure
MPa
℃
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6 °F), 19 °C WB(60°F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°F), 15°C WB(44.6°F) outdoor temp.: 7 °C DB(42.8°F) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m(3.28ft) in front of the unit at a height of *m( 1m(3.28ft) for 105 model,1.2m(3.94ft) for 120~160model). During
actual operation, sound level might be affected by ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
27
38VR014H11901S
4.0
Input
Ambient temp
380-415V-3N~50Hz
38VR010H11901S
3.4
Heating
Refrigerant
380-415V-3N~50Hz
38VR008H11901S
RT
Capacity
Outdoor unit
380-415V-3N~50Hz
38VR007H119010
15.5
EER
Fan motor
Sales Model
14
Input
Compressor
38VR006H119010
12
Cooling
Refrigerant
Pipe
38VR005H119010
kW
Capacity
Coneectable
indoor unit
38VR004H119010
Capacity
Cooling
Capacity
Heating
Outdoor sound level(*3)
Pipe
connections
Connectable
Compressor
Total capacity
Max.quantity
Capacity
Crankcase
Type
Quantity
Fan Motor
Output
Airflow
Outdoor unit
Dimension(W x H x D)
Net/Gross weight
Refrigerant
Type
Charged volume
g
EXV
Throttle type
Design pressure
Ambient temp
4.4/2.6
MPa
°F(°C)
-5~48
-5~48
-5~48
-5~48
-5~48
-15~27
-15~27
-15~27
-15~24
-15~24
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6 °F), 19 °C WB(60°F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°F), 15°C WB(44.6°F) outdoor temp.: 7 °C DB(42.8°F) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m(3.28ft) in front of the unit at a height of *m( 1m(3.28ft) for 105 model,1.2m(3.94ft) for 120~160model). During
actual operation, sound level might be affected by ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
28
Outdoor Unit
DC Inverter Mini H Series
208/230V~1Ph~60Hz
220-240V~1Ph~50Hz
38VR004H11301S
38VR004H113010
38VR005H113010
38VR006H113010
38VR003H112010
38VR004H11201S
38VR004H112010
Specifications 50Hz
38VR005H112010
38VR006H112010
Model
Power supply
Specifications 60Hz&50Hz
38VR004H11301S
38VR004H113010
38VR005H113010
38VR006H113010
V-Ph-Hz
208-230V-1Ph~60Hz
208-230V-1Ph~60Hz
208-230V-1Ph~60Hz
208-230V-1Ph~60Hz
kW
10.5
12
14
15.5
RT
3
3.4
4.0
4.4
Input
kW
2.68
3.25
3.95
4.52
EER
kW/kW
3.92
3.69
3.54
3.43
kW
11.5
13.2
15.4
17
RT
3.3
3.8
4.4
4.9
Power supply
Capacity
Capacity
Heating
Input
kW
2.9
3.47
4.16
4.77
COP
kW/kW
3.97
3.80
3.70
3.56
%
50-130%
50-130%
50-130%
50-130%
5
6
6
7
dB(A)
57
57
57
57
Coneectable
Total capacity
indoor unit
Max.quantity
Outdoor sound level (*3)
Pipe
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
connections
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф19.1
Type
Rotary
Rotary
Rotary
Rotary
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
MITSUBISHI
Btu/h
24330
33710
33710
47713
Input
W
2200
3010
3010
14573
Crankcase
W
25
27
25
20
Type
FV50S
FV50S
FV50S
FV50S
ml
870
870
870
1400
DC motor
DC motor
DC motor
DC motor
1
2
2
2
W
170
2 x 85
2 x 85
2 x 85
CFM
3000
3531
3531
3531
m3/h
5100
6000
6000
6000
Dimension (W x H x D)
mm
1075x966x396
900x1327x400
Packing (W x H x D)
mm
1120x1100x435
1030x1456x435
kg
78/85
Capacity
Compressor
Refrigerant oil
Type
Quantity
Fan Motor
Output
Air floor rate
Outdoor unit
Net/Gross weight
Refrigerant
Design pressure
95/106
102/113
kg
MPa
3
3.3
3.9
3.9
EXV
EXV
EXV
EXV
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Cooling
℃
-15~43℃
Heating
℃
-15~27℃
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6°F), 19°C WB(60 °F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°C), 15°C WB(44.6°F) outdoor temp.: 7°C DB(42.8°F ) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(0.9m for 80model, 1m for 105 model,1.2m for 120~160model). During actual
operation, these values are normally somewhat higher as a result of ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
29
15.5
RT
2.3
2.9
3.4
4.0
4.4
kW
3.4
3.75
3.95
4.85
5.65
2.35
2.67
3.04
2.89
2.74
kW
9
11.5
13.2
15.4
17
RT
2.6
3.3
3.8
4.4
4.9
kW
2.8
3.5
3.55
4.35
5.5
3.21
3.29
3.72
3.54
3.09
50-130%
50-130%
50-130%
50-130%
50-130%
4
5
6
6
7
dB(A)
56
57
57
57
59
Liquid side
mm
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Type
Rotary
Rotary
Rotary
Rotary
Rotary
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
MITSUBISHI
MITSUBISHI
Btu/h
24334
24334
33642
33642
47700
Crankcase
W
25
25
25
25
25
Refrigerant oil
ml
FV50S 870ml+630ml
FV50S 1400ml+250ml
Input
COP
Total capacity
%
Max.quantity
Outndoor sound level
(sound pressure level )
Capacity
Quantities
1
2
2
2
Type
DCmotor
DCmotor
DCmotor
DCmotor
DCmotor
Brand
Panasonic
Panasonic
Panasonic
Panasonic
Panasonic
W
170
170
2*85
2*85
2*85
m3/h
5500
5500
6000
6000
6000
CFM
3235
3235
3529
3529
3529
Dimension(W*H*D)
mm
1075*966*396
1075*966*396
900*1327*320
900*1327*320
900*1327*320
Packing (W*H*D)
mm
1105x1005x435
1105*1005*435
1030*1456*435
1030*1456*435
1030*1456*435
Net/Gross weight
kg
62/67
72/79
95/106
95/106
100/111
R410A
R410A
R410A
R410A
R410A
2800
3000
3300
3900
3900
EXV
EXV
EXV
EXV
EXV
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Cooling -15~43
Cooling -15~43
Cooling -15~43
Cooling -15~43
Cooling -15~43
Heating -15~27
Heating -15~27
Heating -15~27
Heating -15~27
Heating -15~27
Air flow rate
Type
Charged volume
g
Throttle type
Design pressure
Ambient temp
FV50S 670ml+200ml FV50S 670ml+200ml FV50S 870ml+630ml
1
Output
Refrigerant
220-240V-1PH-50Hz
14
Heating
Fan motor
220-240V-1PH-50Hz 220-240V-1PH-50Hz 220-240V-1PH-50Hz 220-240V-1PH-50Hz
38VR006H112010
12
Capacity
Compressor
38VR005H112010
10
EER
Refrigerant
Pipe
38VR004H112010
8
Input
Coneectable
indoor unit
38VR004H11201S
kW
Cooling
Outdoor unit
R410a
Throttle type
Ambient
temperature range
95/106
Type
Charged volume
V-Ph-Hz
Capacity
Sale Model
Cooling
38VR003H112010
MPa
℃
30
Outdoor Unit
DC Inverter Mini H Series
208/230V~1Ph~60Hz
220-240V~1Ph~50Hz
38VR004H11301S
38VR004H113010
38VR005H113010
38VR006H113010
38VR003H112010
38VR004H11201S
38VR004H112010
Specifications 50Hz
38VR005H112010
38VR006H112010
Model
Power supply
Specifications 60Hz&50Hz
38VR004H11301S
38VR004H113010
38VR005H113010
38VR006H113010
V-Ph-Hz
208-230V-1Ph~60Hz
208-230V-1Ph~60Hz
208-230V-1Ph~60Hz
208-230V-1Ph~60Hz
kW
10.5
12
14
15.5
RT
3
3.4
4.0
4.4
Input
kW
2.68
3.25
3.95
4.52
EER
kW/kW
3.92
3.69
3.54
3.43
kW
11.5
13.2
15.4
17
RT
3.3
3.8
4.4
4.9
Power supply
Capacity
Capacity
Heating
Input
kW
2.9
3.47
4.16
4.77
COP
kW/kW
3.97
3.80
3.70
3.56
%
50-130%
50-130%
50-130%
50-130%
5
6
6
7
dB(A)
57
57
57
57
Coneectable
Total capacity
indoor unit
Max.quantity
Outdoor sound level (*3)
Pipe
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
connections
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф19.1
Type
Rotary
Rotary
Rotary
Rotary
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
MITSUBISHI
Btu/h
24330
33710
33710
47713
Input
W
2200
3010
3010
14573
Crankcase
W
25
27
25
20
Type
FV50S
FV50S
FV50S
FV50S
ml
870
870
870
1400
DC motor
DC motor
DC motor
DC motor
1
2
2
2
W
170
2 x 85
2 x 85
2 x 85
CFM
3000
3531
3531
3531
m3/h
5100
6000
6000
6000
Dimension (W x H x D)
mm
1075x966x396
900x1327x400
Packing (W x H x D)
mm
1120x1100x435
1030x1456x435
kg
78/85
Capacity
Compressor
Refrigerant oil
Type
Quantity
Fan Motor
Output
Air floor rate
Outdoor unit
Net/Gross weight
Refrigerant
Design pressure
95/106
102/113
kg
MPa
3
3.3
3.9
3.9
EXV
EXV
EXV
EXV
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Cooling
℃
-15~43℃
Heating
℃
-15~27℃
Note:
1. The cooling conditions: indoor temp.: 27°C DB(80.6°F), 19°C WB(60 °F) outdoor temp.: 35°C DB(95°F) equivalent pipe length: 5m drop length: 0m.
2. The heating conditions: indoor temp.: 20°C DB(68°C), 15°C WB(44.6°F) outdoor temp.: 7°C DB(42.8°F ) equivalent pipe length: 5m drop length: 0m.
3. Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of *m(0.9m for 80model, 1m for 105 model,1.2m for 120~160model). During actual
operation, these values are normally somewhat higher as a result of ambient conditions.
4. The above data may be changed without notice for future improvement on quality and performance.
29
15.5
RT
2.3
2.9
3.4
4.0
4.4
kW
3.4
3.75
3.95
4.85
5.65
2.35
2.67
3.04
2.89
2.74
kW
9
11.5
13.2
15.4
17
RT
2.6
3.3
3.8
4.4
4.9
kW
2.8
3.5
3.55
4.35
5.5
3.21
3.29
3.72
3.54
3.09
50-130%
50-130%
50-130%
50-130%
50-130%
4
5
6
6
7
dB(A)
56
57
57
57
59
Liquid side
mm
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Type
Rotary
Rotary
Rotary
Rotary
Rotary
Brand
MITSUBISHI
MITSUBISHI
MITSUBISHI
MITSUBISHI
MITSUBISHI
Btu/h
24334
24334
33642
33642
47700
Crankcase
W
25
25
25
25
25
Refrigerant oil
ml
FV50S 870ml+630ml
FV50S 1400ml+250ml
Input
COP
Total capacity
%
Max.quantity
Outndoor sound level
(sound pressure level )
Capacity
Quantities
1
2
2
2
Type
DCmotor
DCmotor
DCmotor
DCmotor
DCmotor
Brand
Panasonic
Panasonic
Panasonic
Panasonic
Panasonic
W
170
170
2*85
2*85
2*85
m3/h
5500
5500
6000
6000
6000
CFM
3235
3235
3529
3529
3529
Dimension(W*H*D)
mm
1075*966*396
1075*966*396
900*1327*320
900*1327*320
900*1327*320
Packing (W*H*D)
mm
1105x1005x435
1105*1005*435
1030*1456*435
1030*1456*435
1030*1456*435
Net/Gross weight
kg
62/67
72/79
95/106
95/106
100/111
R410A
R410A
R410A
R410A
R410A
2800
3000
3300
3900
3900
EXV
EXV
EXV
EXV
EXV
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Cooling -15~43
Cooling -15~43
Cooling -15~43
Cooling -15~43
Cooling -15~43
Heating -15~27
Heating -15~27
Heating -15~27
Heating -15~27
Heating -15~27
Air flow rate
Type
Charged volume
g
Throttle type
Design pressure
Ambient temp
FV50S 670ml+200ml FV50S 670ml+200ml FV50S 870ml+630ml
1
Output
Refrigerant
220-240V-1PH-50Hz
14
Heating
Fan motor
220-240V-1PH-50Hz 220-240V-1PH-50Hz 220-240V-1PH-50Hz 220-240V-1PH-50Hz
38VR006H112010
12
Capacity
Compressor
38VR005H112010
10
EER
Refrigerant
Pipe
38VR004H112010
8
Input
Coneectable
indoor unit
38VR004H11201S
kW
Cooling
Outdoor unit
R410a
Throttle type
Ambient
temperature range
95/106
Type
Charged volume
V-Ph-Hz
Capacity
Sale Model
Cooling
38VR003H112010
MPa
℃
30
Dimension
Unit Dimensions, unit: mm(in)
966(38-1/32)
8/10.5kW
366(14-13/32)
396(15-19/32)
336(13-15/64)
354(13-15/16)
624(24-9/16)
Indoor Units Lineup
990(38-31/32)
1075(42-21/64)
12/14/16kW
400(15-3/4)
360(14-11/16)
320(12-19/32)
One-way Cassette
1327(52-1/4)
348(13-45/64)
600(23-5/8)
Two-way Cassette
Compact Four-way Cassette
Fat pipe
Front out pipe
900(35-7/16)
R
Unit installation
Side out pipe
Standard Four-way Cassette
Low Static Pressure Duct
Back out pipe Undersurface out pipe
R amplification
Concealed Duct Unit (A5 Type)
Single Unit installation
>1.97ft
(0.6m)
High Static Pressure Duct
Ceiling&Floor
>9.84ft
(3m)
Air inlet
Maintain
channel
Air inlet
>1.97ft
(0.6m)
>6.56ft
(2m)
Fix with bolt
>0.98ft
(0.3m)
(Wall or obstacle)
Wall-mounted
Fresh Air Processing Unit
Air outlet
Parallel installation
>0.98ft
(0.3m)
>6.56ft
(2m)
31
>1.97ft
(0.6m)
>6.56ft
(2m)
>1.64ft
(0.5m)
>9.84ft
(3m)
>9.84ft
(3m)
>0.98ft
(0.3m)
32
Dimension
Unit Dimensions, unit: mm(in)
966(38-1/32)
8/10.5kW
366(14-13/32)
396(15-19/32)
336(13-15/64)
354(13-15/16)
624(24-9/16)
Indoor Units Lineup
990(38-31/32)
1075(42-21/64)
12/14/16kW
400(15-3/4)
360(14-11/16)
320(12-19/32)
One-way Cassette
1327(52-1/4)
348(13-45/64)
600(23-5/8)
Two-way Cassette
Compact Four-way Cassette
Fat pipe
Front out pipe
900(35-7/16)
R
Unit installation
Side out pipe
Standard Four-way Cassette
Low Static Pressure Duct
Back out pipe Undersurface out pipe
R amplification
Concealed Duct Unit (A5 Type)
Single Unit installation
>1.97ft
(0.6m)
High Static Pressure Duct
Ceiling&Floor
>9.84ft
(3m)
Air inlet
Maintain
channel
Air inlet
>1.97ft
(0.6m)
>6.56ft
(2m)
Fix with bolt
>0.98ft
(0.3m)
(Wall or obstacle)
Wall-mounted
Fresh Air Processing Unit
Air outlet
Parallel installation
>0.98ft
(0.3m)
>6.56ft
(2m)
31
>1.97ft
(0.6m)
>6.56ft
(2m)
>1.64ft
(0.5m)
>9.84ft
(3m)
>9.84ft
(3m)
>0.98ft
(0.3m)
32
Type
One-way Cassette
40VZ***H11200011
40VZ***H11300011
Two-way Cassette
40VT***H11300010
40VT***H10200010
Compact Four-way Cassette
Model
18
22
28
36
45
56
71
80
90
100
112
125
140
160
200
250
280
400
450
560
40.0
45.0
56.0
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
8.0
9.0
10.0
11.2
12.5
14.0
16.0
20.0
25.0
28.0
Btu/h
6,100
7,500
9,600
12,300
15,400
19,100
24,200
27,300
30,700
34,100
38,200
42,700
47,800
54,600
68,200
85,300
95,500
Ton
0.5
0.6
0.8
1
1.3
1.6
2.0
2.3
2.6
2.9
3.2
3.5
4.0
5.0
5.7
7.1
8
11.4
12.8
16
HP
0.6
0.8
1
1.25
1.6
2
2.5
2.8
3.2
3.6
4
4.5
5
6
8
9
10
14
16
20
136,500 153,500 170,600
40VX***H11300010
40VX***H11200010
Four-way Cassette
40VK***H11300011
40VK***H11200011
Low Static Pressure Duct
42VD***H113002011
42VD***H112002011
42VD***H113003010
42VD***H112003010
Concealed Duct Unit(A5 Type)
42VD***H113003011
42VD***H112013011
42VD***H113011010
42VD***H112011010
High Static Pressure Duct
42VD***H113011010
42VD***H112011010
42VD***H113011010
42VD***H112011010
Ceiling & Floor
42VF***H113000010
42VF***H112000010
42VH***H113000101
42VH***H112000101
Wall-mounted
42VH***H113000100
42VH***H112000102
Fresh Air Processing Unit
42VD***H113211010
42VD***H112211010
11 types and more than 100 models are available to meet varied customer requirements.
33
34
Type
One-way Cassette
40VZ***H11200011
40VZ***H11300011
Two-way Cassette
40VT***H11300010
40VT***H10200010
Compact Four-way Cassette
Model
18
22
28
36
45
56
71
80
90
100
112
125
140
160
200
250
280
400
450
560
40.0
45.0
56.0
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
8.0
9.0
10.0
11.2
12.5
14.0
16.0
20.0
25.0
28.0
Btu/h
6,100
7,500
9,600
12,300
15,400
19,100
24,200
27,300
30,700
34,100
38,200
42,700
47,800
54,600
68,200
85,300
95,500
Ton
0.5
0.6
0.8
1
1.3
1.6
2.0
2.3
2.6
2.9
3.2
3.5
4.0
5.0
5.7
7.1
8
11.4
12.8
16
HP
0.6
0.8
1
1.25
1.6
2
2.5
2.8
3.2
3.6
4
4.5
5
6
8
9
10
14
16
20
136,500 153,500 170,600
40VX***H11300010
40VX***H11200010
Four-way Cassette
40VK***H11300011
40VK***H11200011
Low Static Pressure Duct
42VD***H113002011
42VD***H112002011
42VD***H113003010
42VD***H112003010
Concealed Duct Unit(A5 Type)
42VD***H113003011
42VD***H112013011
42VD***H113011010
42VD***H112011010
High Static Pressure Duct
42VD***H113011010
42VD***H112011010
42VD***H113011010
42VD***H112011010
Ceiling & Floor
42VF***H113000010
42VF***H112000010
42VH***H113000101
42VH***H112000101
Wall-mounted
42VH***H113000100
42VH***H112000102
Fresh Air Processing Unit
42VD***H113211010
42VD***H112211010
11 types and more than 100 models are available to meet varied customer requirements.
33
34
Specifications 60Hz
One-way Cassette
Model
Auto Restart
Fresh Air
Auto Addressing
Cleanable Panel
40VZ006H11300011 40VZ007H11300011 40VZ009H11300011 40VZ012H11300011 40VZ016H11300011 40VZ020H11300011 40VZ024H11300011
Power Supply
208-230V-1Ph-60Hz
V-Ph-Hz
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
Btu/h
6100
7500
9600
12300
15400
19100
24200
Input
W
41
41
41
41
54
60
75
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
kW
2.2
2.6
3.2
4
5
6.3
8
Btu/h
7500
8900
10900
13600
17100
21500
27300
Input
W
41
41
41
41
44
50
65
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
m³/h
523/404/275
523/404/275
573/456/315
573/456/315
693/600/476
792/688/549
933/749/592
CFM
308/238/162
308/238/162
337/268/185
337/268/185
408/353/280
466/405/323
549/441/349
dB(A)
37/34/30
38/34/30
39/37/34
40/38/34
41/39/35
42/40/36
44/41/37
Capacity
Follow Me
Anti-Cold Air Function
Cooling
LED
Built-in Drain Pump
LED Display
DISPLAY
Capacity
Heating
Only 153mm thickness
Auto swing
Compact design,ultra slim body with a minimum thickness of
153mm for model 18-36,especially suitable for narrow ceiling
, such as in lobbies and small meeting rooms.
Auto swing mechanism guarantees even
airflow distribution and a better room
temperature balance.
Indoor air flow(H/M/L)
Indoor noise level(H/M/L)
153mm
Dimension(WxHxD)
UItra Thin
Indoor unit Packing(WxHxD)
Single-flow design suits
corner installation
Standard built-in drain pump with 750mm pump head.
Net/Gross weight
Panel
750mm
mm
1054×153×425
1204×189×443
mm
1155×245×490
1370×295×505
kg
13/16.5
12.5/16
Reserved fresh air intake port for high quality air
creates a comfortable and healthy environment.
Only for 4.5-7.1kw unit.
1180×25×465
1350×25×505
Packing(WxHxD)
mm
1232×107×517
1410×95×560
Net/Gross weight
kg
4/5.4
3.5/5.2
R410A
EXV
Design pressure(H/L)
MPa
Refrigerant Liquid side
mm
Ф6.35
Ф12.7
mm
Ф12.7
Ф15.9
piping
Gas side
Drainage water pipe dia.
Controller
mm
4.4/2.6
OD Ф25
Wireless remote controller
Note:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
Acetaldehyde
Acetic acid
35
19.5/24.2
mm
Throttle
Special enzyme sterilization and filtering technologies
filter bacteria, smog, and pollen. Provide a clean,
healthy and natural air supply.
18.8/23.5
Dimension(WxHxD)
Refrigerant type
Fresh air, improved air quality
18.5/23.2
Formol
NH3
36
Specifications 60Hz
One-way Cassette
Model
Auto Restart
Fresh Air
Auto Addressing
Cleanable Panel
40VZ006H11300011 40VZ007H11300011 40VZ009H11300011 40VZ012H11300011 40VZ016H11300011 40VZ020H11300011 40VZ024H11300011
Power Supply
208-230V-1Ph-60Hz
V-Ph-Hz
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
Btu/h
6100
7500
9600
12300
15400
19100
24200
Input
W
41
41
41
41
54
60
75
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
kW
2.2
2.6
3.2
4
5
6.3
8
Btu/h
7500
8900
10900
13600
17100
21500
27300
Input
W
41
41
41
41
44
50
65
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
m³/h
523/404/275
523/404/275
573/456/315
573/456/315
693/600/476
792/688/549
933/749/592
CFM
308/238/162
308/238/162
337/268/185
337/268/185
408/353/280
466/405/323
549/441/349
dB(A)
37/34/30
38/34/30
39/37/34
40/38/34
41/39/35
42/40/36
44/41/37
Capacity
Follow Me
Anti-Cold Air Function
Cooling
LED
Built-in Drain Pump
LED Display
DISPLAY
Capacity
Heating
Only 153mm thickness
Auto swing
Compact design,ultra slim body with a minimum thickness of
153mm for model 18-36,especially suitable for narrow ceiling
, such as in lobbies and small meeting rooms.
Auto swing mechanism guarantees even
airflow distribution and a better room
temperature balance.
Indoor air flow(H/M/L)
Indoor noise level(H/M/L)
153mm
Dimension(WxHxD)
UItra Thin
Indoor unit Packing(WxHxD)
Single-flow design suits
corner installation
Standard built-in drain pump with 750mm pump head.
Net/Gross weight
Panel
750mm
mm
1054×153×425
1204×189×443
mm
1155×245×490
1370×295×505
kg
13/16.5
12.5/16
Reserved fresh air intake port for high quality air
creates a comfortable and healthy environment.
Only for 4.5-7.1kw unit.
1180×25×465
1350×25×505
Packing(WxHxD)
mm
1232×107×517
1410×95×560
Net/Gross weight
kg
4/5.4
3.5/5.2
R410A
EXV
Design pressure(H/L)
MPa
Refrigerant Liquid side
mm
Ф6.35
Ф12.7
mm
Ф12.7
Ф15.9
piping
Gas side
Drainage water pipe dia.
Controller
mm
4.4/2.6
OD Ф25
Wireless remote controller
Note:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
Acetaldehyde
Acetic acid
35
19.5/24.2
mm
Throttle
Special enzyme sterilization and filtering technologies
filter bacteria, smog, and pollen. Provide a clean,
healthy and natural air supply.
18.8/23.5
Dimension(WxHxD)
Refrigerant type
Fresh air, improved air quality
18.5/23.2
Formol
NH3
36
Two-way Cassette
Specifications 50Hz
Model
40VZ006H11200011 40VZ007H11200011 40VZ009H11200011 40VZ012H11200011 40VZ016H11200011 40VZ020H11200011 40VZ024H11200011
Power Supply
220-240V-1Ph-50Hz
V-Ph-Hz
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
Btu/h
6100
7500
9600
12300
15400
19100
24200
Input
W
41
41
41
41
48
48
60
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
kW
2.2
2.6
3.2
4
5
6.3
8
Btu/h
7500
8900
10900
13600
17100
21500
27300
Input
W
41
41
41
41
43
44
55
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
m³/h
523/404/275
523/404/275
573/456/315
573/456/315
693/600/476
792/688/549
933/749/592
CFM
308/238/162
308/238/162
337/268/185
337/268/185
408/353/280
466/405/323
549/441/349
dB(A)
37/34/30
38/34/30
39/37/34
40/38/34
41/39/35
42/40/36
44/41/37
Capacity
Cooling
LED
Auto Restart
Fresh Air
Auto Addressing
Cleanable Panel
Follow Me
Anti-Cold Air Function
LED Display
DISPLAY
Capacity
Built-in Drain Pump
Heating
Indoor air flow(H/M/L)
Indoor noise level(H/M/L)
Dimension(WxHxD)
Indoor unit Packing(WxHxD)
Net/Gross weight
Panel
mm
1054×153×425
1204×189×443
mm
1155×245×490
1370×295×505
kg
13/16.5
12.5/16
18.5/23.2
18.8/23.5
mm
1180×25×465
1350×25×505
Packing(WxHxD)
mm
1232×107×517
1410×95×560
Net/Gross weight
kg
3.5/5.2
High airflow
Optimized airflow duct with low resistance makes
noise level get reduced greatly, min. 24dB(A).
High airflow for high ceiling application guarantees equal comfort of large space. It makes
every customer of the room get even distribution of airflow and temperature.
Stylish design and slim body
19.5/24.2
Dimension(WxHxD)
Quiet operation
Thanks to the stylish appearance and slim body, the
unit can be harmonious with the room decoration and
ambient. Slim body with only 11-13/16in.(300mm)
height needs small suspended ceiling space. Installation is free of story height limitation which makes the
decoration much more flexible.
4/5.4
R410A
Refrigerant type
11-13/16in.(300mm)
EXV
Throttle
4.4/2.6
Design pressure(H/L)
MPa
Refrigerant Liquid side
mm
Ф6.35
Ф12.7
mm
Ф12.7
Ф15.9
piping
12in.(305mm)
Gas side
Drainage water pipe dia.
Controller
mm
OD Ф25
Standard built-in drain pump with 29-17/32in.(750mm)
pump head (higher pumphead can be customized).
29-17/32in.
(750mm)
Wireless remote controller
Note:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
37
Flat-type suction grille design makes maintenance
work very easy.
38
Two-way Cassette
Specifications 50Hz
Model
40VZ006H11200011 40VZ007H11200011 40VZ009H11200011 40VZ012H11200011 40VZ016H11200011 40VZ020H11200011 40VZ024H11200011
Power Supply
220-240V-1Ph-50Hz
V-Ph-Hz
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
Btu/h
6100
7500
9600
12300
15400
19100
24200
Input
W
41
41
41
41
48
48
60
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
kW
2.2
2.6
3.2
4
5
6.3
8
Btu/h
7500
8900
10900
13600
17100
21500
27300
Input
W
41
41
41
41
43
44
55
Rated current
A
0.24
0.24
0.25
0.25
0.27
0.32
0.36
m³/h
523/404/275
523/404/275
573/456/315
573/456/315
693/600/476
792/688/549
933/749/592
CFM
308/238/162
308/238/162
337/268/185
337/268/185
408/353/280
466/405/323
549/441/349
dB(A)
37/34/30
38/34/30
39/37/34
40/38/34
41/39/35
42/40/36
44/41/37
Capacity
Cooling
LED
Auto Restart
Fresh Air
Auto Addressing
Cleanable Panel
Follow Me
Anti-Cold Air Function
LED Display
DISPLAY
Capacity
Built-in Drain Pump
Heating
Indoor air flow(H/M/L)
Indoor noise level(H/M/L)
Dimension(WxHxD)
Indoor unit Packing(WxHxD)
Net/Gross weight
Panel
mm
1054×153×425
1204×189×443
mm
1155×245×490
1370×295×505
kg
13/16.5
12.5/16
18.5/23.2
18.8/23.5
mm
1180×25×465
1350×25×505
Packing(WxHxD)
mm
1232×107×517
1410×95×560
Net/Gross weight
kg
3.5/5.2
High airflow
Optimized airflow duct with low resistance makes
noise level get reduced greatly, min. 24dB(A).
High airflow for high ceiling application guarantees equal comfort of large space. It makes
every customer of the room get even distribution of airflow and temperature.
Stylish design and slim body
19.5/24.2
Dimension(WxHxD)
Quiet operation
Thanks to the stylish appearance and slim body, the
unit can be harmonious with the room decoration and
ambient. Slim body with only 11-13/16in.(300mm)
height needs small suspended ceiling space. Installation is free of story height limitation which makes the
decoration much more flexible.
4/5.4
R410A
Refrigerant type
11-13/16in.(300mm)
EXV
Throttle
4.4/2.6
Design pressure(H/L)
MPa
Refrigerant Liquid side
mm
Ф6.35
Ф12.7
mm
Ф12.7
Ф15.9
piping
12in.(305mm)
Gas side
Drainage water pipe dia.
Controller
mm
OD Ф25
Standard built-in drain pump with 29-17/32in.(750mm)
pump head (higher pumphead can be customized).
29-17/32in.
(750mm)
Wireless remote controller
Note:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
37
Flat-type suction grille design makes maintenance
work very easy.
38
Specifications 50Hz
Specifications 60Hz
Model
40VT007H11300010 40VT009H11300010 40VT012H11300010 40VT016H11300010 40VT020H11300010 40VT024H11300010
Power supply
208-230V-1Ph~60Hz
V-Ph-Hz
kW
2.2
2.8
3.6
4.5
5.6
7.1
Btu/h
7500
9600
12300
15400
19100
2.2
2.8
3.6
4.5
5.6
7.1
BTU
7500
9600
12300
15400
19100
24200
Input
W
65
65
65
97
112
153
Rated current
A
0.35
0.45
0.45
0.55
0.55
0.75
kW
2.6
3.2
4
5
6.3
8
BTU
8900
10900
13600
17100
21500
27300
Input
W
65
65
65
97
112
153
Rated current
A
0.35
0.45
0.45
0.55
0.55
0.75
m3/h
654/530/410
654/530/410
725/591/458
850/670/550
980/800/670
1200/1000/770
CFM
385/312/241
385/312/241
427/348/270
7
577/471/394
706/589/453
dB(A)
33/29/24
36/32/29
36/32/29
39/35/30
39/35/30
44/40/34
Dimension (W×H×D)
mm
1172×300×592
1172×300×592
1172×300×592
1172×300×592
1172×300×592
1172×300×592
Packing (W×H×D)
mm
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
kg
33/42
33/42
33/42
35/44
35/44
35/44
Dimension (W×H×D)
mm
1430×90×680
1430×90×680
1430×90×680
1430×90×680
1430×90×680
1430×90×680
Packing (W×H×D)
mm
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
kg
10.5/15
10.5/15
10.5/15
10.5/15
10.5/15
10.5/15
R410A
R410A
R410A
R410A
R410A
R410A
24200
Input
W
78
78
83
115
133
205
Rated current
A
0.33
0.33
0.36
0.5
0.57
0.87
kW
2.6
3.2
4
5
6.3
8
Btu/h
8900
10900
13600
17100
21500
27300
Cooling
Capacity
Heating
Input
W
78
78
83
115
133
205
Rated current
A
0.33
0.33
0.36
0.5
0.57
0.87
m3/h
674/509/381
674/509/381
740/577/435
878/689/561
941/776/654
1236/1110/864
CFM
397/300/224
397/300/224
436/340/256
517/406/330
554/457/385
727/653/509
dB(A)
33/29/24
36/32/29
36/32/29
39/35/30
39/35/30
44/40/34
Dimension (WxHxD)
mm
1172×299×591
1172×299×591
1172×299×591
1172×299×591
1172×299×591
1172×299×591
Indoor unit Packing (WxHxD)
mm
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
Net/Gross weight
kg
34/42.5
34/42.5
34/42.5
36.5/45
36.5/45
36.5/45
Dimension (WxHxD)
mm
1430×53×680
1430×53×680
1430×53×680
1430×53×680
1430×53×680
1430×53×680
Packing (WxHxD)
mm
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
Net/Gross weight
(kg)
34/42.5
34/42.5
34/42.5
36/44.5
36/44.5
36/44.5
EXV
EXV
EXV
EXV
EXV
EXV
Capacity
Heating
Indoor air flow (H/M/L)
Indoor noise level (Hi/Mid/Lo)
Indoor unit
Net/Gross weight
Panel
Panel
Throttle
220-240V-1ph-50Hz
kW
Capacity
Cooling
Indoor noise level (H/M/L)
V-Ph-Hz
Power supply
Capacity
Indoor air flow (H/M/L)
40VT007H10200010 40VT009H10200010 40VT012H10200010 40VT016H10200010 40VT020H10200010 40VT024H10200010
Model
Net/Gross weight
Refrigerant type
Throttle
Design pressure(H/ L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф9.53
Ф9.53
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф15.9
Ф15.9
mm
ID Φ25,OD Φ32
ID Φ25,OD Φ32
ID Φ25,OD Φ32
ID Φ25,OD Φ32
EXV
Design pressure
Refrigerant
piping
Drainage water pipe diameter
Controller
ID Φ25,OD Φ32 ID Φ25,OD Φ32
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
39
Refrigerant
piping
MPa
Liquid side
mm
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Ф9.53
Ф9.53
Gas side
mm
Φ12.7
Φ12.7
Φ12.7
Φ12.7
Ф15.9
Ф15.9
Drainage water pipe dia.
Controller
4.4/2.6
mm
ID Ф25, OD Ф32
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
40
Specifications 50Hz
Specifications 60Hz
Model
40VT007H11300010 40VT009H11300010 40VT012H11300010 40VT016H11300010 40VT020H11300010 40VT024H11300010
Power supply
208-230V-1Ph~60Hz
V-Ph-Hz
kW
2.2
2.8
3.6
4.5
5.6
7.1
Btu/h
7500
9600
12300
15400
19100
2.2
2.8
3.6
4.5
5.6
7.1
BTU
7500
9600
12300
15400
19100
24200
Input
W
65
65
65
97
112
153
Rated current
A
0.35
0.45
0.45
0.55
0.55
0.75
kW
2.6
3.2
4
5
6.3
8
BTU
8900
10900
13600
17100
21500
27300
Input
W
65
65
65
97
112
153
Rated current
A
0.35
0.45
0.45
0.55
0.55
0.75
m3/h
654/530/410
654/530/410
725/591/458
850/670/550
980/800/670
1200/1000/770
CFM
385/312/241
385/312/241
427/348/270
7
577/471/394
706/589/453
dB(A)
33/29/24
36/32/29
36/32/29
39/35/30
39/35/30
44/40/34
Dimension (W×H×D)
mm
1172×300×592
1172×300×592
1172×300×592
1172×300×592
1172×300×592
1172×300×592
Packing (W×H×D)
mm
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
kg
33/42
33/42
33/42
35/44
35/44
35/44
Dimension (W×H×D)
mm
1430×90×680
1430×90×680
1430×90×680
1430×90×680
1430×90×680
1430×90×680
Packing (W×H×D)
mm
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
kg
10.5/15
10.5/15
10.5/15
10.5/15
10.5/15
10.5/15
R410A
R410A
R410A
R410A
R410A
R410A
24200
Input
W
78
78
83
115
133
205
Rated current
A
0.33
0.33
0.36
0.5
0.57
0.87
kW
2.6
3.2
4
5
6.3
8
Btu/h
8900
10900
13600
17100
21500
27300
Cooling
Capacity
Heating
Input
W
78
78
83
115
133
205
Rated current
A
0.33
0.33
0.36
0.5
0.57
0.87
m3/h
674/509/381
674/509/381
740/577/435
878/689/561
941/776/654
1236/1110/864
CFM
397/300/224
397/300/224
436/340/256
517/406/330
554/457/385
727/653/509
dB(A)
33/29/24
36/32/29
36/32/29
39/35/30
39/35/30
44/40/34
Dimension (WxHxD)
mm
1172×299×591
1172×299×591
1172×299×591
1172×299×591
1172×299×591
1172×299×591
Indoor unit Packing (WxHxD)
mm
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
1355×400×675
Net/Gross weight
kg
34/42.5
34/42.5
34/42.5
36.5/45
36.5/45
36.5/45
Dimension (WxHxD)
mm
1430×53×680
1430×53×680
1430×53×680
1430×53×680
1430×53×680
1430×53×680
Packing (WxHxD)
mm
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
1525×130×765
Net/Gross weight
(kg)
34/42.5
34/42.5
34/42.5
36/44.5
36/44.5
36/44.5
EXV
EXV
EXV
EXV
EXV
EXV
Capacity
Heating
Indoor air flow (H/M/L)
Indoor noise level (Hi/Mid/Lo)
Indoor unit
Net/Gross weight
Panel
Panel
Throttle
220-240V-1ph-50Hz
kW
Capacity
Cooling
Indoor noise level (H/M/L)
V-Ph-Hz
Power supply
Capacity
Indoor air flow (H/M/L)
40VT007H10200010 40VT009H10200010 40VT012H10200010 40VT016H10200010 40VT020H10200010 40VT024H10200010
Model
Net/Gross weight
Refrigerant type
Throttle
Design pressure(H/ L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф9.53
Ф9.53
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф15.9
Ф15.9
mm
ID Φ25,OD Φ32
ID Φ25,OD Φ32
ID Φ25,OD Φ32
ID Φ25,OD Φ32
EXV
Design pressure
Refrigerant
piping
Drainage water pipe diameter
Controller
ID Φ25,OD Φ32 ID Φ25,OD Φ32
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
39
Refrigerant
piping
MPa
Liquid side
mm
Φ6.35
Φ6.35
Φ6.35
Φ6.35
Ф9.53
Ф9.53
Gas side
mm
Φ12.7
Φ12.7
Φ12.7
Φ12.7
Ф15.9
Ф15.9
Drainage water pipe dia.
Controller
4.4/2.6
mm
ID Ф25, OD Ф32
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
40
Compact Four-way Cassette
Specifications 60Hz
40VX007H11300010
Model
Power supply
40VX012H11300010
40VX016H11300010
40VX020H11300010
208-230V-1Ph~60Hz
V-ph-Hz
Fresh Air
Auto Restart
40VX009H11300010
kW
2.2
2.8
3.6
4.5
5.6
Btu/h
7500
9600
12300
15400
19100
Input
W
50
50
60
60
60
Rated current
A
0.175
0.175
0.21
0.21
0.21
kW
2.4
3.2
4
5
6.3
Btu/h
8200
10900
13600
17100
21500
Input
W
50
50
60
60
60
Rated current
A
0.175
0.175
0.21
0.21
0.21
m3/h
532/397/292/215
539/408/310/231
632/496/359/263
632/496/359/263
632/496/359/263
CFM
313/234/172/127
317/240/182/136
372/292/211/155
372/292/211/155
372/292/211/155
dB(A)
35.8/33.4/23.4
35.8/33.4/23.4
41.5/35.6/28.8
41.5/35.6/28.8
41.5/35.6/28.8
Dimension (W×H×D)
mm
570×265×570
570×265×570
570×265×570
570×265×570
570×265×570
Packing (W×H×D)
mm
675×285×675
675×285×675
675×285×675
675×285×675
675×285×675
Net/Gross weight
kg
16/20
16/20
18/22
18/22
18/22
Dimension (W×H×D)
mm
647×50×647
647×50×647
647×50×647
647×50×647
647×50×647
Packing (W×H×D)
mm
715×113×715
715×113×715
715×113×715
715×113×715
715×113×715
Net/Gross weight
lbs. (kg)
3/5
3/5
3/5
3/5
3/5
R410a
R410a
R410a
R410a
R410a
Capacity
Auto Addressing
Cleanable Panel
Cooling
Anti-Cold Air Function
Follow Me
Built-in Drain Pump
LED
LED Display
DISPLAY
Super High Air Flow
Capacity
Heating
Compact design, easy installation and maintenance
(22-7
in
16
-7/
/16in
)
mm
0
(57
(570
mm)
(22
Extremely compact casing makes it perfectly match with
the ambient decoration. Little space is required for
installation into a shallow ceiling.
Due to its compact body and light weight, all models can
be installed without a hoist.
Indoor air flow (H/M/L)
Sound level (sound pressure)
Indoor unit
Quiet operation, soft air supply
Uniform air flow of four ways
Diffuser
Panel
3-D spiral fan blade
Refrigerant
Streamline plate ensures quietness
Advanced 3-D spiral fan design reduces the air
resistance and operation noise.
360°Airflow outlet
360°air outlet provides strong
circulating air flow to cool or
heat every corner of the room
and realizes even temperature
distribution.
41
The four air discharge port provides strong circulating
air flow to cool or heat every corner of the room and
realizes even temperature distribution; by choosing high
airflow mode, high ceiling application over 1/8in.(3m)
can get equal comfort.
Type
Throttle
Electric expansive valve
Design pressure(H/L)
Refrigerant
piping
Lift pump
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
mm
OD Ф25)
OD Ф25)
OD Ф25)
OD Ф25)
OD Ф25)
Drainage water pipe diameter
19-11/16 in.
(500mm)
controller
Wireless remote controller
Notes:
Drain up pump with 19-11/16 in.(500mm) pump head
fitted as standard, max. up to 600mm pump head.
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
42
Compact Four-way Cassette
Specifications 60Hz
40VX007H11300010
Model
Power supply
40VX012H11300010
40VX016H11300010
40VX020H11300010
208-230V-1Ph~60Hz
V-ph-Hz
Fresh Air
Auto Restart
40VX009H11300010
kW
2.2
2.8
3.6
4.5
5.6
Btu/h
7500
9600
12300
15400
19100
Input
W
50
50
60
60
60
Rated current
A
0.175
0.175
0.21
0.21
0.21
kW
2.4
3.2
4
5
6.3
Btu/h
8200
10900
13600
17100
21500
Input
W
50
50
60
60
60
Rated current
A
0.175
0.175
0.21
0.21
0.21
m3/h
532/397/292/215
539/408/310/231
632/496/359/263
632/496/359/263
632/496/359/263
CFM
313/234/172/127
317/240/182/136
372/292/211/155
372/292/211/155
372/292/211/155
dB(A)
35.8/33.4/23.4
35.8/33.4/23.4
41.5/35.6/28.8
41.5/35.6/28.8
41.5/35.6/28.8
Dimension (W×H×D)
mm
570×265×570
570×265×570
570×265×570
570×265×570
570×265×570
Packing (W×H×D)
mm
675×285×675
675×285×675
675×285×675
675×285×675
675×285×675
Net/Gross weight
kg
16/20
16/20
18/22
18/22
18/22
Dimension (W×H×D)
mm
647×50×647
647×50×647
647×50×647
647×50×647
647×50×647
Packing (W×H×D)
mm
715×113×715
715×113×715
715×113×715
715×113×715
715×113×715
Net/Gross weight
lbs. (kg)
3/5
3/5
3/5
3/5
3/5
R410a
R410a
R410a
R410a
R410a
Capacity
Auto Addressing
Cleanable Panel
Cooling
Anti-Cold Air Function
Follow Me
Built-in Drain Pump
LED
LED Display
DISPLAY
Super High Air Flow
Capacity
Heating
Compact design, easy installation and maintenance
(22-7
in
16
-7/
/16in
)
mm
0
(57
(570
mm)
(22
Extremely compact casing makes it perfectly match with
the ambient decoration. Little space is required for
installation into a shallow ceiling.
Due to its compact body and light weight, all models can
be installed without a hoist.
Indoor air flow (H/M/L)
Sound level (sound pressure)
Indoor unit
Quiet operation, soft air supply
Uniform air flow of four ways
Diffuser
Panel
3-D spiral fan blade
Refrigerant
Streamline plate ensures quietness
Advanced 3-D spiral fan design reduces the air
resistance and operation noise.
360°Airflow outlet
360°air outlet provides strong
circulating air flow to cool or
heat every corner of the room
and realizes even temperature
distribution.
41
The four air discharge port provides strong circulating
air flow to cool or heat every corner of the room and
realizes even temperature distribution; by choosing high
airflow mode, high ceiling application over 1/8in.(3m)
can get equal comfort.
Type
Throttle
Electric expansive valve
Design pressure(H/L)
Refrigerant
piping
Lift pump
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
mm
OD Ф25)
OD Ф25)
OD Ф25)
OD Ф25)
OD Ф25)
Drainage water pipe diameter
19-11/16 in.
(500mm)
controller
Wireless remote controller
Notes:
Drain up pump with 19-11/16 in.(500mm) pump head
fitted as standard, max. up to 600mm pump head.
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
42
Standard Four-way Cassette Type
Specifications 50Hz
40VX007H11200010
Model
Power supply
40VX009H11200010
40VX012H11200010
40VX016H11200010
V-ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
kW
2.2
2.8
3.6
4.5
BTU
9600
12300
15400
19100
Input
W
50
50
58
58
Rated current
A
0.175
0.175
0.21
0.21
kW
2.4
3.2
4
5
BTU
10900
13600
17100
21500
Input
W
42
42
50
50
Rated current
A
0.175
0.175
0.21
0.21
m3/h
522/414/313/238
522/414/313/238
610/521/409/314
610/521/409/314
CFM
307/244/184/140
307/244/184/140
359/307/241/185
359/307/241/185
dB(A)
35.8/33.4/23.4
35.8/33.4/23.4
41.5/35.6/28.8
41.5/35.6/28.8
Dimension (W×H×D)
mm
630×260×570
630×260×570
630×260×570
630×260×570
Packing (W×H×D)
mm
675×285×675
675×285×675
675×285×675
675×285×675
Net/Gross weight
Kg
16/20
16/20
18/22
18/22
Dimension (W×H×D)
mm
647×50×647
647×50×647
647×50×647
647×50×647
Packing (W×H×D)
mm
715×123×715
715×123×715
715×123×715
715×123×715
Net/Gross weight
Kg
2.5/4.5
2.5/4.5
2.5/4.5
2.5/4.5
R410a
R410a
R410a
R410a
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
mm
ODФ25
ODФ25
ODФ25
ODФ25
Capacity
Cooling
Auto Restart
Fresh Air
Auto Addressing
Cleanable Panel
Follow Me
Anti-Cold Air Function
Built-in Drain Pump
LED
LED Display
Super High Air Flow
Capacity
Heating
Lower operating sound
The new designed wind wheel, ring and the built-in throttling part make the noise reduced greatly.
Indoor air flow (SH/Hi/Mi/Lo)
Sound level (sound pressure)
Indoor unit
Panel
Refrigerant Type
Design pressure
Refrigerant
piping
Drainage water pipe dia.
Wireless remote controller
Wirelesscontroller
The former wind wheel
Optimized wind wheel
More reliable
■ The connection of drainage pan adopts foaming technology which can further improve the connection
tightness.
■ Capacitor is isolated by sheet metal box making more safety and higher reliability.
■ The strong and weak electricity wires are separated in electronic control box making the interference
decreased greatly.
Flexible air distribution type
■ 7 discharge patterns in 2 to 4 directions can be
selected to suit the requirements of installation site
or the shape of the room.
■ Duct connection is possible.
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
43
44
Standard Four-way Cassette Type
Specifications 50Hz
40VX007H11200010
Model
Power supply
40VX009H11200010
40VX012H11200010
40VX016H11200010
V-ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
kW
2.2
2.8
3.6
4.5
BTU
9600
12300
15400
19100
Input
W
50
50
58
58
Rated current
A
0.175
0.175
0.21
0.21
kW
2.4
3.2
4
5
BTU
10900
13600
17100
21500
Input
W
42
42
50
50
Rated current
A
0.175
0.175
0.21
0.21
m3/h
522/414/313/238
522/414/313/238
610/521/409/314
610/521/409/314
CFM
307/244/184/140
307/244/184/140
359/307/241/185
359/307/241/185
dB(A)
35.8/33.4/23.4
35.8/33.4/23.4
41.5/35.6/28.8
41.5/35.6/28.8
Dimension (W×H×D)
mm
630×260×570
630×260×570
630×260×570
630×260×570
Packing (W×H×D)
mm
675×285×675
675×285×675
675×285×675
675×285×675
Net/Gross weight
Kg
16/20
16/20
18/22
18/22
Dimension (W×H×D)
mm
647×50×647
647×50×647
647×50×647
647×50×647
Packing (W×H×D)
mm
715×123×715
715×123×715
715×123×715
715×123×715
Net/Gross weight
Kg
2.5/4.5
2.5/4.5
2.5/4.5
2.5/4.5
R410a
R410a
R410a
R410a
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
mm
ODФ25
ODФ25
ODФ25
ODФ25
Capacity
Cooling
Auto Restart
Fresh Air
Auto Addressing
Cleanable Panel
Follow Me
Anti-Cold Air Function
Built-in Drain Pump
LED
LED Display
Super High Air Flow
Capacity
Heating
Lower operating sound
The new designed wind wheel, ring and the built-in throttling part make the noise reduced greatly.
Indoor air flow (SH/Hi/Mi/Lo)
Sound level (sound pressure)
Indoor unit
Panel
Refrigerant Type
Design pressure
Refrigerant
piping
Drainage water pipe dia.
Wireless remote controller
Wirelesscontroller
The former wind wheel
Optimized wind wheel
More reliable
■ The connection of drainage pan adopts foaming technology which can further improve the connection
tightness.
■ Capacitor is isolated by sheet metal box making more safety and higher reliability.
■ The strong and weak electricity wires are separated in electronic control box making the interference
decreased greatly.
Flexible air distribution type
■ 7 discharge patterns in 2 to 4 directions can be
selected to suit the requirements of installation site
or the shape of the room.
■ Duct connection is possible.
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature: 95°F(35°C)
DB,equivalent ref. piping: 26.25ft(8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)
WB, and equivalent ref. piping: 26.25ft (8m) (horizontal).
3.Sound Level is measured 4.59ft.(1.4m) below the unit.
43
44
Specifications 60Hz
Specifications 50Hz
Model
40VK009H11300011 40VK012H11300011 40VK016H11300011 40VK020H11300011
Power supply
Capacity
Cooling
Power input
Rated Current
Capacity
Heating
Power input
Rated Current
2.8
3.6
4.5
5.6
7.1
12283
15354
19107
24225
W
80
80
88
88
105
A
0.36
0.36
0.39
0.39
0.47
kW
3.2
4.0
5.0
6.3
8.0
Btu/h
10918
13648
17060
21496
27296
W
80
80
88
88
105
A
0.36
0.36
0.39
0.39
0.47
791/674/596
791/674/596
942/777/662
942/777/662
1235/1013/805
CFM
465/396/351
465/396/351
554/457/389
554/457/389
726/596/474
dB(A)
30/25/22
30/25/22
35/31/27
35/31/27
43/37/31
Net dimension (W×H×D)
mm
840×230×840
840×230×840
840×230×840
840×230×840
840×230×840
Packing size (W×H×D)
mm
955×260×955
955×260×955
955×260×955
955×260×955
955×260×955
Net/Gross weight
kg
21.5/26.7
21.5/26.7
23.7/28.9
23.7/28.9
23.7/28.9
Net dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing size (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Sound pressure level (H/M/L)
Panel
kW
Btu/h
Refrigerant type
Model
40VK009H11200011
Power supply
m3/h
Indoor air flow (H/M/L)
Indoor Unit
40VK024H11300011
208-230V-1Ph~60Hz
Capacity
Cooling
Input
Rated current
Capacity
Heating
Input
Rated current
Indoor air flow (SH/H/M/L)
Panel
40VK016H11200011
40VK020H11200011
40VK024H11200011
220-240V, 1Ph, 50Hz
kW
2.8
3.6
4.5
5.6
7.1
BTU
9600
80
12300
80
15400
90
19100
90
24200
90
W
A
0.4
0.4
0.4
0.4
0.5
kW
3.2
4
5
6.3
8
BTU
10900
80
13600
80
17100
90
21500
90
27300
90
W
A
0.4
0.4
0.4
0.4
0.5
m3/h
920/764/638/554
920/764/638/554
1090/905/740/651
1090/905/740/651
1140/950/767/663
670/560/451/390
CFM
541/450/375/326
541/450/375/326
641/532/435/383
641/532/435/383
dB(A)
32/31/30
32/31/30
36/34/33
36/34/33
38/36/35
Dimension (W×H×D)
mm
840×230×840
840×230×840
840×230×840
840×230×840
840×230×840
955×260×955
Indoor noise level (Hi/Mid/Lo)
Indoor unit
40VK012H11200011
V-Ph-Hz
Packing (W×H×D)
mm
955×260×955
955×260×955
955×260×955
955×260×955
Net/Gross weight
kg
21.5/26.7
21.5/26.7
23.7/28.9
23.7/28.9
23.7/28.9
Dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Refrigerant type
Throttle type
Type
EXV
EXV
EXV
EXV
EXV
Throttle
Type
EXV
EXV
EXV
EXV
EXV
Design pressure (H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Design pressure
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid pipe
mm
Φ6.35
Φ6.35
Φ6.35
Φ9.53
Φ9.53
Gas pipe
mm
Φ12.7
Φ12.7
Φ12.7
Φ15.9
Φ15.9
Refrigerant
piping
Drain pipe
mm
OD Φ32
OD Φ32
OD Φ32
OD Φ32
OD Φ32
Pipe connections
Controller
Wireless remote controller
Model
Cooling
kW
8.0
9.0
10.0
11.2
14.0
27296
30708
34120
38214
47768
Power input
W
120
187
200
200
220
Rated Current
A
0.53
0.83
0.89
0.89
0.98
kW
9.0
10.0
11.1
12.5
16.0
Btu/h
30708
34120
37873
42650
54592
Power input
W
120
187
200
200
220
Rated Current
A
0.53
0.83
0.89
0.89
0.98
m3/h
1235/1013/805
1333/1158/957
1634/1219/1139
1634/1219/1139
1692/1243/1157
CFM
726/596/474
784/681/563
961/717/670
961/717/670
995/731/681
dB(A)
43/37/31
43/38/32
45/37/35
45/37/35
46/38/37
Net dimension (W×H×D)
mm
840×230×840
840×300×840
840×300×840
840×300×840
840×300×840
Packing size (W×H×D)
mm
955×260×955
955×330×955
955×330×955
955×330×955
955×330×955
Net/Gross weight
kg
23.7/28.9
28.7/34.1
28.7/34.1
28.7/34.1
30.9/36.3
Net dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing size (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Indoor air flow (H/M/L)
Sound pressure level (H/M/L)
Indoor Unit
Panel
Refrigerant type
Throttle type
Type
EXV
EXV
EXV
EXV
EXV
Design pressure (H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid pipe
mm
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Gas pipe
mm
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Drain pipe
mm
OD Φ32
OD Φ32
OD Φ32
OD Φ32
OD Φ32
Pipe connections
Controller
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB, equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
45
Φ6.35
Φ6.35
Φ6.35
Φ9.53
Φ9.53
Φ12.7
Φ12.7
Φ12.7
Φ15.9
Φ15.9
Drainage water pipe dia.
mm
Model
Power supply
Btu/h
Capacity
Heating
40VK048H11300011
208-230V-1Ph~60Hz
Capacity
mm
mm
Controller
40VK028H11300011 40VK030H11300011 40VK034H11300011 40VK036H11300011
Power supply
Liquid side/
Gas side
Input
Rated current
Capacity
Heating
Input
Rated current
Indoor air flow (SH/H/M/L)
Panel
ODФ32
ODФ32
ODФ32
Wireless controller
Wireless controller
Wireless controller
40VK028H11200011
40VK030H11200011
40VK034H11200011
40VK036H11200011
40VK048H11200011
220-240V, 1Ph, 50Hz
kW
8
9
10
11.2
14
BTU
W
27300
97
30700
155
34100
155
38200
155
47800
180
0.8
A
0.5
0.7
0.7
0.7
kW
9
10
11
12.5
15
BTU
30700
97
34100
155
37500
155
42700
155
51200
180
0.7
0.7
0.8
W
A
0.5
0.7
m3/h
1380/1200/1021/789
1598/1332/1129/908
1750/1651/1304/1127 1750/1651/1304/1127 1774/1658/1335/1130
CFM
812/706/600/464
940/784/664/534
1029/971/767/663
1029/971/767/663
dB(A)
42/39/37
43/39/38
45/42/40
45/42/40
46/41/39
Dimension (W×H×D)
mm
840×230×840
840×300×840
840×300×840
840×300×840
840×300×840
Packing (W×H×D)
mm
955×260×955
955×330×955
955×330×955
955×330×955
955×330×955
Net/Gross weight
kg
23.7/28.9
28.7/34.1
28.7/34.1
28.7/34.1
30.9/36.3
Dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Indoor noise level (Hi/Mid/Lo)
Indoor unit
ODФ32
Wireless controller
V-Ph-Hz
Capacity
Cooling
ODФ32
Wireless controller
Refrigerant type
1044/975/785/665
Throttle
Type
EXV
EXV
EXV
EXV
EXV
Design pressure
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Refrigerant
piping
Liquid side/
mm
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Gas side
mm
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Drainage water pipe dia.
Controller
mm
ODФ32
ODФ32
ODФ32
ODФ32
ODФ32
Wireless controller
Wireless controller
Wireless controller
Wireless controller
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB, equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
46
Specifications 60Hz
Specifications 50Hz
Model
40VK009H11300011 40VK012H11300011 40VK016H11300011 40VK020H11300011
Power supply
Capacity
Cooling
Power input
Rated Current
Capacity
Heating
Power input
Rated Current
2.8
3.6
4.5
5.6
7.1
12283
15354
19107
24225
W
80
80
88
88
105
A
0.36
0.36
0.39
0.39
0.47
kW
3.2
4.0
5.0
6.3
8.0
Btu/h
10918
13648
17060
21496
27296
W
80
80
88
88
105
A
0.36
0.36
0.39
0.39
0.47
791/674/596
791/674/596
942/777/662
942/777/662
1235/1013/805
CFM
465/396/351
465/396/351
554/457/389
554/457/389
726/596/474
dB(A)
30/25/22
30/25/22
35/31/27
35/31/27
43/37/31
Net dimension (W×H×D)
mm
840×230×840
840×230×840
840×230×840
840×230×840
840×230×840
Packing size (W×H×D)
mm
955×260×955
955×260×955
955×260×955
955×260×955
955×260×955
Net/Gross weight
kg
21.5/26.7
21.5/26.7
23.7/28.9
23.7/28.9
23.7/28.9
Net dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing size (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Sound pressure level (H/M/L)
Panel
kW
Btu/h
Refrigerant type
Model
40VK009H11200011
Power supply
m3/h
Indoor air flow (H/M/L)
Indoor Unit
40VK024H11300011
208-230V-1Ph~60Hz
Capacity
Cooling
Input
Rated current
Capacity
Heating
Input
Rated current
Indoor air flow (SH/H/M/L)
Panel
40VK016H11200011
40VK020H11200011
40VK024H11200011
220-240V, 1Ph, 50Hz
kW
2.8
3.6
4.5
5.6
7.1
BTU
9600
80
12300
80
15400
90
19100
90
24200
90
W
A
0.4
0.4
0.4
0.4
0.5
kW
3.2
4
5
6.3
8
BTU
10900
80
13600
80
17100
90
21500
90
27300
90
W
A
0.4
0.4
0.4
0.4
0.5
m3/h
920/764/638/554
920/764/638/554
1090/905/740/651
1090/905/740/651
1140/950/767/663
670/560/451/390
CFM
541/450/375/326
541/450/375/326
641/532/435/383
641/532/435/383
dB(A)
32/31/30
32/31/30
36/34/33
36/34/33
38/36/35
Dimension (W×H×D)
mm
840×230×840
840×230×840
840×230×840
840×230×840
840×230×840
955×260×955
Indoor noise level (Hi/Mid/Lo)
Indoor unit
40VK012H11200011
V-Ph-Hz
Packing (W×H×D)
mm
955×260×955
955×260×955
955×260×955
955×260×955
Net/Gross weight
kg
21.5/26.7
21.5/26.7
23.7/28.9
23.7/28.9
23.7/28.9
Dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Refrigerant type
Throttle type
Type
EXV
EXV
EXV
EXV
EXV
Throttle
Type
EXV
EXV
EXV
EXV
EXV
Design pressure (H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Design pressure
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid pipe
mm
Φ6.35
Φ6.35
Φ6.35
Φ9.53
Φ9.53
Gas pipe
mm
Φ12.7
Φ12.7
Φ12.7
Φ15.9
Φ15.9
Refrigerant
piping
Drain pipe
mm
OD Φ32
OD Φ32
OD Φ32
OD Φ32
OD Φ32
Pipe connections
Controller
Wireless remote controller
Model
Cooling
kW
8.0
9.0
10.0
11.2
14.0
27296
30708
34120
38214
47768
Power input
W
120
187
200
200
220
Rated Current
A
0.53
0.83
0.89
0.89
0.98
kW
9.0
10.0
11.1
12.5
16.0
Btu/h
30708
34120
37873
42650
54592
Power input
W
120
187
200
200
220
Rated Current
A
0.53
0.83
0.89
0.89
0.98
m3/h
1235/1013/805
1333/1158/957
1634/1219/1139
1634/1219/1139
1692/1243/1157
CFM
726/596/474
784/681/563
961/717/670
961/717/670
995/731/681
dB(A)
43/37/31
43/38/32
45/37/35
45/37/35
46/38/37
Net dimension (W×H×D)
mm
840×230×840
840×300×840
840×300×840
840×300×840
840×300×840
Packing size (W×H×D)
mm
955×260×955
955×330×955
955×330×955
955×330×955
955×330×955
Net/Gross weight
kg
23.7/28.9
28.7/34.1
28.7/34.1
28.7/34.1
30.9/36.3
Net dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing size (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Indoor air flow (H/M/L)
Sound pressure level (H/M/L)
Indoor Unit
Panel
Refrigerant type
Throttle type
Type
EXV
EXV
EXV
EXV
EXV
Design pressure (H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Liquid pipe
mm
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Gas pipe
mm
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Drain pipe
mm
OD Φ32
OD Φ32
OD Φ32
OD Φ32
OD Φ32
Pipe connections
Controller
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB, equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
45
Φ6.35
Φ6.35
Φ6.35
Φ9.53
Φ9.53
Φ12.7
Φ12.7
Φ12.7
Φ15.9
Φ15.9
Drainage water pipe dia.
mm
Model
Power supply
Btu/h
Capacity
Heating
40VK048H11300011
208-230V-1Ph~60Hz
Capacity
mm
mm
Controller
40VK028H11300011 40VK030H11300011 40VK034H11300011 40VK036H11300011
Power supply
Liquid side/
Gas side
Input
Rated current
Capacity
Heating
Input
Rated current
Indoor air flow (SH/H/M/L)
Panel
ODФ32
ODФ32
ODФ32
Wireless controller
Wireless controller
Wireless controller
40VK028H11200011
40VK030H11200011
40VK034H11200011
40VK036H11200011
40VK048H11200011
220-240V, 1Ph, 50Hz
kW
8
9
10
11.2
14
BTU
W
27300
97
30700
155
34100
155
38200
155
47800
180
0.8
A
0.5
0.7
0.7
0.7
kW
9
10
11
12.5
15
BTU
30700
97
34100
155
37500
155
42700
155
51200
180
0.7
0.7
0.8
W
A
0.5
0.7
m3/h
1380/1200/1021/789
1598/1332/1129/908
1750/1651/1304/1127 1750/1651/1304/1127 1774/1658/1335/1130
CFM
812/706/600/464
940/784/664/534
1029/971/767/663
1029/971/767/663
dB(A)
42/39/37
43/39/38
45/42/40
45/42/40
46/41/39
Dimension (W×H×D)
mm
840×230×840
840×300×840
840×300×840
840×300×840
840×300×840
Packing (W×H×D)
mm
955×260×955
955×330×955
955×330×955
955×330×955
955×330×955
Net/Gross weight
kg
23.7/28.9
28.7/34.1
28.7/34.1
28.7/34.1
30.9/36.3
Dimension (W×H×D)
mm
950×46×950
950×46×950
950×46×950
950×46×950
950×46×950
Packing (W×H×D)
mm
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
1035×90×1035
Net/Gross weight
kg
6/9
6/9
6/9
6/9
6/9
R410A
R410A
R410A
R410A
R410A
Indoor noise level (Hi/Mid/Lo)
Indoor unit
ODФ32
Wireless controller
V-Ph-Hz
Capacity
Cooling
ODФ32
Wireless controller
Refrigerant type
1044/975/785/665
Throttle
Type
EXV
EXV
EXV
EXV
EXV
Design pressure
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Refrigerant
piping
Liquid side/
mm
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Φ9.53
Gas side
mm
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Φ15.9
Drainage water pipe dia.
Controller
mm
ODФ32
ODФ32
ODФ32
ODФ32
ODФ32
Wireless controller
Wireless controller
Wireless controller
Wireless controller
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB, equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
46
Low Static Pressure Duct
Specifications 60Hz
Model
Anti-Cold Air Function
Auto Addressing
Super High Air Flow
Capacity
Cooling
Follow Me
Heating
1.8
2.2
2.8
3.6
6100
7500
9600
12300
W
59
59
59
65
A
0.26
0.26
0.26
0.3
kW
2.2
2.6
3.2
4
Btu/h
7500
8900
10900
13600
Input
W
59
59
59
65
Rated current
A
0.26
0.26
0.26
0.3
Indoor external static pressure
m3/h
606/578/512/409
CFM
357/340/301/241
blower, provides a minimum
noise level of 24dB (A), an
excellent choice for hotels
380/363/324/260
10(10-30)
10(10-30)
10(10-30)
dB(A)
35/27/24
35/27/24
35/27/24
38/32/28
Dimension (W×H×D)
in.(mm)
740×210×470
740×210×470
740×210×470
740×210×470
Packing (W×H×D)
in.(mm)
910×230×510
910×230×510
910×230×510
910×230×510
Net/Gross weight
kg
Refrigerant type
Utilizes the centrifugal type
646/617/551/441
Pa
Indoor noise level (H/M/L)
Low sound level
kW
Btu/h
Rated current
Indoor air flow (SH/H/M/L)
Indoor unit
42VD012H113002011
Input
Capacity
Wireless remote controller
42VD009H113002011
208-230V~, 1Ph, 60Hz
V- Ph-Hz
Power supply
Auto Restart
42VD007H113002011
42VD006H113002011
10(10~30)
14.5/18
14.5/18
14.5/18
14.5/18
R410A
R410A
R410A
R410A
Throttle
Type
EXV
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Refrigerant
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
piping
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
mm
OD Ф25
OD Ф25
OD Ф25
OD Ф25
Drainage water pipe diameter
Controller
Wireless remote controller
and other sound-sensitive
places.
42VD016H113002011
Model
kW
4.5
5.6
7.1
Btu/h
15400
19100
24200
Input
W
105
105
130
Rated current
A
0.5
0.5
0.6
kW
5
6.3
8
Btu/h
17100
21500
27300
Input
W
105
105
130
Rated current
A
0.5
0.5
Capacity
V shape evaporator design enhances heat exchanging
efficiency about 22%.
Convenient for
installation
installation
and maintenance
The EXV is fixed inside the indoor unit.
Cooling
Capacity
Heating
Indoor air flow (SH/H/M/L)
Compact design
Options
Indoor external static pressure
Indoor noise level (H/M/L)
Min.5mm
29-17/32in.(750mm)
Ceiling
Uniform 8-17/64in.(210mm) in height, compact
design for easy locate where space ceiling is limited,
The whole body adopts fireproof plastic material,
the minimum weight is 30.9lbs(14kg).
ceiling
A drain pump with 29-17/32in.(750mm)
pumphead is an optional accessory.
803/824/690/609
m /h
3
CFM
0.6
1207/1060/970/811
473/485/406/358
710/624/571/477
Pa
10(10~30)
10(10~30)
dB(A)
39/32/29
39/32/29
41/33/30
10(10~30)
Dimension (W×H×D)
in.(mm)
960×210×470
1180×210×470
Packing (W×H×D)
in.(mm)
1130×230×510
1350×230×510
Net/Gross weight
kg
Refrigerant type
8-17/64in.(210mm)
47
Indoor unit
42VD024H113002011
208-230V~, 1Ph, 60Hz
V- Ph-Hz
Power supply
V
shape
evaporator-good
heat
More
Smooth
airflow with
lessfor
turbulence
exchanging
42VD020H113002011
18/22.5
22.5/26.5
R410A
R410A
R410A
Throttle
Type
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
Refrigerant
Liquid side
mm
Ф6.35
Ф9.53
Ф9.53
piping
Gas side
mm
Ф12.7
Ф15.9
Ф15.9
mm
OD Ф25
OD Ф25
OD Ф25
Drainage water pipe diameter
Controller
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB,
equivalent ref. piping: 8m (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB,
and equivalent ref. Piping: 8m (horizontal).
3.Sound level is measured at 1.4m below the air outlet.
* External static pressure is based on high speed indoor air flow.
48
Low Static Pressure Duct
Specifications 60Hz
Model
Anti-Cold Air Function
Auto Addressing
Super High Air Flow
Capacity
Cooling
Follow Me
Heating
1.8
2.2
2.8
3.6
6100
7500
9600
12300
W
59
59
59
65
A
0.26
0.26
0.26
0.3
kW
2.2
2.6
3.2
4
Btu/h
7500
8900
10900
13600
Input
W
59
59
59
65
Rated current
A
0.26
0.26
0.26
0.3
Indoor external static pressure
m3/h
606/578/512/409
CFM
357/340/301/241
blower, provides a minimum
noise level of 24dB (A), an
excellent choice for hotels
380/363/324/260
10(10-30)
10(10-30)
10(10-30)
dB(A)
35/27/24
35/27/24
35/27/24
38/32/28
Dimension (W×H×D)
in.(mm)
740×210×470
740×210×470
740×210×470
740×210×470
Packing (W×H×D)
in.(mm)
910×230×510
910×230×510
910×230×510
910×230×510
Net/Gross weight
kg
Refrigerant type
Utilizes the centrifugal type
646/617/551/441
Pa
Indoor noise level (H/M/L)
Low sound level
kW
Btu/h
Rated current
Indoor air flow (SH/H/M/L)
Indoor unit
42VD012H113002011
Input
Capacity
Wireless remote controller
42VD009H113002011
208-230V~, 1Ph, 60Hz
V- Ph-Hz
Power supply
Auto Restart
42VD007H113002011
42VD006H113002011
10(10~30)
14.5/18
14.5/18
14.5/18
14.5/18
R410A
R410A
R410A
R410A
Throttle
Type
EXV
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Refrigerant
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
piping
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
mm
OD Ф25
OD Ф25
OD Ф25
OD Ф25
Drainage water pipe diameter
Controller
Wireless remote controller
and other sound-sensitive
places.
42VD016H113002011
Model
kW
4.5
5.6
7.1
Btu/h
15400
19100
24200
Input
W
105
105
130
Rated current
A
0.5
0.5
0.6
kW
5
6.3
8
Btu/h
17100
21500
27300
Input
W
105
105
130
Rated current
A
0.5
0.5
Capacity
V shape evaporator design enhances heat exchanging
efficiency about 22%.
Convenient for
installation
installation
and maintenance
The EXV is fixed inside the indoor unit.
Cooling
Capacity
Heating
Indoor air flow (SH/H/M/L)
Compact design
Options
Indoor external static pressure
Indoor noise level (H/M/L)
Min.5mm
29-17/32in.(750mm)
Ceiling
Uniform 8-17/64in.(210mm) in height, compact
design for easy locate where space ceiling is limited,
The whole body adopts fireproof plastic material,
the minimum weight is 30.9lbs(14kg).
ceiling
A drain pump with 29-17/32in.(750mm)
pumphead is an optional accessory.
803/824/690/609
m /h
3
CFM
0.6
1207/1060/970/811
473/485/406/358
710/624/571/477
Pa
10(10~30)
10(10~30)
dB(A)
39/32/29
39/32/29
41/33/30
10(10~30)
Dimension (W×H×D)
in.(mm)
960×210×470
1180×210×470
Packing (W×H×D)
in.(mm)
1130×230×510
1350×230×510
Net/Gross weight
kg
Refrigerant type
8-17/64in.(210mm)
47
Indoor unit
42VD024H113002011
208-230V~, 1Ph, 60Hz
V- Ph-Hz
Power supply
V
shape
evaporator-good
heat
More
Smooth
airflow with
lessfor
turbulence
exchanging
42VD020H113002011
18/22.5
22.5/26.5
R410A
R410A
R410A
Throttle
Type
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
Refrigerant
Liquid side
mm
Ф6.35
Ф9.53
Ф9.53
piping
Gas side
mm
Ф12.7
Ф15.9
Ф15.9
mm
OD Ф25
OD Ф25
OD Ф25
Drainage water pipe diameter
Controller
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB,
equivalent ref. piping: 8m (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB,
and equivalent ref. Piping: 8m (horizontal).
3.Sound level is measured at 1.4m below the air outlet.
* External static pressure is based on high speed indoor air flow.
48
Specifications 50Hz
42VD006H112002011 42VD007H112002011 42VD009H112002011 42VD012H112002011 42VD016H112002011 42VD020H112002011 42VD024H112002011
Model
V-Hz-Ph
Power supply
Cooling
Heating
220-240V, 1Ph, 50Hz
Capacity
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
Input
W
65
65
65
67
85
85
108
Rated Current
W
0.28
0.28
0.28
0.29
0.37
0.37
0.48
Capacity
kW
2.2
2.6
3.2
4.0
5.0
6.3
8.0
Input
W
67
67
67
70
86
86
110
Rated Current
W
0.29
0.29
0.29
0.31
0.38
0.38
0.49
m3/h
606/578/512/409 606/578/512/409 606/578/512/409 646/617/551/441 803/824/690/609 803/824/690/609 1207/1060/970/811
CFM
357/340/301/241 357/340/301/241 357/340/301/241 380/363/324/260 473/485/406/358 473/485/406/358 710/624/571/477
Indoor air flow (SH/H/M/L)
Indoor external static pressure (H)
Indoor noise level (H/M/L)
Indoor unit
Pa
10(10-30)
10(10-30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
dB(A)
35/27/24
35/27/24
35/27/24
35/27/24
39/32/29
39/32/29
41/33/30
Compact size
Packing (W×H×D)
mm
910×230×510
1130×230×510
1350×230×510
Convenient installation
Net/Gross weight
kg
18/22.5
21.5/26.5
R410A
Throttle
Type
EXV
Design pressure(H/L)
MPa
4.4/2.6
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Drainage water pipe diameter
Controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB,
equivalent ref. piping: 8m (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB,
and equivalent ref. Piping: 8m (horizontal).
3.Sound level is measured at 1.4m below the air outlet.
* External static pressure is based on high speed indoor air flow.
* Specifications are subject to change without prior notice for product improvement.
49
Air intake from below
Super High Air Flow
drain pump as standard
29-17/32
(750mm)
ceiling
ODΦ25
Wireless controller
Auto Addressing
The EXV is fixed inside of the indoor unit.
Standard filter placed in an aluminum frame, which is removable downward from bottom.
Suction chamber is included as standard equipment.
Fresh air hole, air inlet/outlet flange are standard for easy duct connection.
Air inlet from back is standard and from bottom as optional with the same connectable duct.
Air intake from back
Liquid side
Wireless remote
controller
‘H’ to change the ESP.
Ceiling
1180×210×470
18/22.5
Built-in Drain Pump
Change the wiring connection from ‘SH’ to
960×210×470
14/17.5
Anti-Cold Air
Function
an optional)
8-9/32in.
or 10-5/8in.
or 11-13/16in.
740×210×470
14/17.5
Follow Me
Four speed fan motor (Super high speed as
Min.3/16in.(5mm)
mm
14/17.5
Fresh Air
External static pressure
Dimension (W×H×D)
14/17.5
Auto Restart
Connectable To Duct
Only 8-9/32in.(210mm) (22~71 models) or 10-5/8in.
(270mm) (80 to 112 models) or 11-13/16in.(300mm)
(140 model) in height.
Refrigerant type
Refrigerant
piping
Concealed Duct Unit (A5 Type)
Flexible control and convenient for maintenance
Standard wireless remote controller WL-12-CM.
The Electrical control box can be removed 1m away from the unit, easy to access when needs maintenance.
(Should be required by client in advance and done by Carrier in factory).
Standard functional port such as Remote On/Off Dry contact switch and Alarm signal output (220V).
50
Specifications 50Hz
42VD006H112002011 42VD007H112002011 42VD009H112002011 42VD012H112002011 42VD016H112002011 42VD020H112002011 42VD024H112002011
Model
V-Hz-Ph
Power supply
Cooling
Heating
220-240V, 1Ph, 50Hz
Capacity
kW
1.8
2.2
2.8
3.6
4.5
5.6
7.1
Input
W
65
65
65
67
85
85
108
Rated Current
W
0.28
0.28
0.28
0.29
0.37
0.37
0.48
Capacity
kW
2.2
2.6
3.2
4.0
5.0
6.3
8.0
Input
W
67
67
67
70
86
86
110
Rated Current
W
0.29
0.29
0.29
0.31
0.38
0.38
0.49
m3/h
606/578/512/409 606/578/512/409 606/578/512/409 646/617/551/441 803/824/690/609 803/824/690/609 1207/1060/970/811
CFM
357/340/301/241 357/340/301/241 357/340/301/241 380/363/324/260 473/485/406/358 473/485/406/358 710/624/571/477
Indoor air flow (SH/H/M/L)
Indoor external static pressure (H)
Indoor noise level (H/M/L)
Indoor unit
Pa
10(10-30)
10(10-30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
dB(A)
35/27/24
35/27/24
35/27/24
35/27/24
39/32/29
39/32/29
41/33/30
Compact size
Packing (W×H×D)
mm
910×230×510
1130×230×510
1350×230×510
Convenient installation
Net/Gross weight
kg
18/22.5
21.5/26.5
R410A
Throttle
Type
EXV
Design pressure(H/L)
MPa
4.4/2.6
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Drainage water pipe diameter
Controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temp.: 27°CDB, 19°CWB, and outdoor temp.:35°CDB,
equivalent ref. piping: 8m (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temp.: 20°CDB, outdoor temp.: 7°CDB, 6°CWB,
and equivalent ref. Piping: 8m (horizontal).
3.Sound level is measured at 1.4m below the air outlet.
* External static pressure is based on high speed indoor air flow.
* Specifications are subject to change without prior notice for product improvement.
49
Air intake from below
Super High Air Flow
drain pump as standard
29-17/32
(750mm)
ceiling
ODΦ25
Wireless controller
Auto Addressing
The EXV is fixed inside of the indoor unit.
Standard filter placed in an aluminum frame, which is removable downward from bottom.
Suction chamber is included as standard equipment.
Fresh air hole, air inlet/outlet flange are standard for easy duct connection.
Air inlet from back is standard and from bottom as optional with the same connectable duct.
Air intake from back
Liquid side
Wireless remote
controller
‘H’ to change the ESP.
Ceiling
1180×210×470
18/22.5
Built-in Drain Pump
Change the wiring connection from ‘SH’ to
960×210×470
14/17.5
Anti-Cold Air
Function
an optional)
8-9/32in.
or 10-5/8in.
or 11-13/16in.
740×210×470
14/17.5
Follow Me
Four speed fan motor (Super high speed as
Min.3/16in.(5mm)
mm
14/17.5
Fresh Air
External static pressure
Dimension (W×H×D)
14/17.5
Auto Restart
Connectable To Duct
Only 8-9/32in.(210mm) (22~71 models) or 10-5/8in.
(270mm) (80 to 112 models) or 11-13/16in.(300mm)
(140 model) in height.
Refrigerant type
Refrigerant
piping
Concealed Duct Unit (A5 Type)
Flexible control and convenient for maintenance
Standard wireless remote controller WL-12-CM.
The Electrical control box can be removed 1m away from the unit, easy to access when needs maintenance.
(Should be required by client in advance and done by Carrier in factory).
Standard functional port such as Remote On/Off Dry contact switch and Alarm signal output (220V).
50
Specifications 50Hz
Specifications 60Hz
Model
42VD007H113003011 42VD009H113003011 42VD012H113003011 42VD016H113003011 42VD020H113003011
Power supply
kW
2.2
2.8
3.6
4.5
5.6
Btu/h
7500
9600
12300
15400
19100
Input
W
66
72
77
100
100
Rated current
A
0.24
0.24
0.28
0.48
0.48
Capacity
Cooling
kW
2.6
3.2
4
5
6.3
Btu/h
8900
10900
13600
17100
21500
Input
W
66
72
77
100
100
Rated current
A
0.24
0.24
0.28
0.48
0.48
Capacity
Heating
Indoor air flow (SH/H/M/L)
Indoor external static pressure (H)
Indoor noise level (H/M/L)
Indoor unit
208-230V~,1Ph, 60Hz
V- Ph-Hz
m3/h
614/597/514/429
763/811/684/575
763/811/684/575
CFM
588(30pa)/538/456/375 588/538/456/375
346/317/268/221
346/317/268/221
361/351/303/253
449/477/403/338
449/477/403/338
Pa
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
dB(A)
36/35/32
37/35/32
38.6/37.5/33.8
39/37.9/34
39/37.9/34
Dimension (W×H×D)
mm
740x210x500
740x210x500
740x210x500
960x210x500
960x210x500
Packing (W×H×D)
mm
870×285×525
870×285×525
870×285×525
1115×285×525
1115×285×525
Net/Gross weight
kg
22.5/26
22.5/26
Ф92
Ф92
Fresh Air intake hole diameter
mm
17.5/20
(Ф92)
Ф92
Refrigerant type
Ф92
R410A
Throttle
Type
EXV
Design pressure(H/L)
MPa
4.4/2.6
Refrigerant
piping
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф9.53
Gas
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф15.9
OD Ф25
mm
Controller
kW
7.1
8
9
11.2
14
Btu/h
24200
27300
30700
38200
47800
Input
W
125
133
134
378
352
Rated current
A
0.6
1
1
1.8
1.55
kW
8
9
10
12.5
15.5
Capacity
Cooling
Capacity
Heating
Btu/h
27300
30700
34100
42650
52900
Input
W
125
133
134
378
352
Rated current
A
0.6
1
1
1.8
1.55
Indoor air flow (SH/H/M/L)
Indoor external static pressure (H)
Indoor noise level (H/M/L)
Indoor unit
208-230V~,1Ph, 60Hz
V- Ph-Hz
m3/h
1127/1029/934/781 1388/1345/1165/1013 1388/1345/1165/1013 1851/1800/1556/1400 1745)/1905/1636/1400
CFM
663/606/550/460
817/792/686/596
817/792/686/596
1089/1059/916/824
1027/1121/963/824
Pa
10(10~30)
20(10~50)
20(10~50)
40(10~80)
40(10~100)
dB(A)
41.4/39/35
45.4/39.8/37
45.4/39.8/37
48.0 /41.9/38
47.7/43.2/39.0
Dimension (W×H×D)
mm
1180x210x500
1180×270×775
1180×270×775
1180×270×775
1240×300×865
Packing (W×H×D)
mm
1335×285×525
1355×350×795
1355×350×795
1355×350×795
1400×375×925
Net/Gross weight
kg
28/31.5
38/46.5
40/48
40/48
49/58
mm
Ф92
Ф125
Ф125
Ф125
Ф125
Fresh Air intake hole diameter
Refrigerant type
R410A
Throttle
Type
EXV
Design pressure(H/L)
MPa
4.4/2.6
Refrigerant
piping
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Controller
mm
OD Ф25
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB,
and equivalent ref. piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* external static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
51
3.6
4.5
5.6
7.1
24200
7500
9600
12300
15400
19100
W
68
68
72
80
80
105
Rated current
A
0.36
0.36
0.39
0.43
0.43
0.56
kW
2.6
3.2
4
5
6.3
8.0
BTU
8900
10900
13600
17100
21500
27300
Input
W
65
65
69
80
80
105
Rated current
A
0.36
0.36
0.39
0.43
0.43
0.56
m3/h
588/538/456/375
588/538/456/375
614/597/514/429
763/811/684/575
763/811/684/575 1127/1029/934/781
CFM
346/317/268/221
346/317/268/221
361/351/303/253
449/477/403/338
449/477/403/338
Pa
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
dB(A)
36/35/32
37/35/32
38.6/37.5/33.8
39/37.9/34
39/37.9/34
41.4/39/35
Static pressure (Min.~Max.)
Sound level (sound pressure)
mm
740*210*500
960*210*500
1180*210*500
Packing (W×H×D)
mm
870*285*525
1115*285*525
1335*285*525
Net/Gross weight
kg
17.5/21
17.5/21
17.5/21
22.5/26
22.5/26
28/31.5
mm
Ф92
Ф92
Ф92
Ф92
Ф92
Ф92
Fresh Air Intake Size (round)
R410A
Throttle
Type
EXV
Design pressure
MPa
4.4/2.6
Refrigerant
piping
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф9.53
Ф9.53
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф15.9
Ф15.9
mm
OD Ф25
Wireless controller
42VD028H112003010 42VD030H112003010 42VD034H112003010 42VD036H112003010 42VD042H112003010 42VD048H112003010
Model
Power supply
14
327
355
355
1.8
1.9
1.9
11
12.5
13.5
15.5
8
9
10
11.2
BTU
27300
30700
38200
47800
Input
W
231
231
327
Rated current
A
1
1
1.8
kW
9
10
BTU
30700
34100
42650
52900
Input
W
231
231
327
327
355
355
Rated current
A
1
1
1.8
1.8
1.9
1.9
Indoor air flow (/Hi/Mi/Lo)
Static pressure (Min.~Max.)
Sound level (sound pressure)
Indoor unit
12.5
kW
Capacity
Heating
220-240V, 1Ph, 50Hz
V-ph-Hz
Capacity
Cooling
m3/h
CFM
1388/1345/1165/1013 1388/1345/1165/1013 1851/1800/1556/1400 1851/1800/1556/1400 1745/1905/1636/1400 1745/1905/1636/1400
817/792/686/596
817/792/686/596 1089/1059/916/824 1089/1059/916/824 1027/1121/963/824 1027/1121/963/824
Pa
20(10~50)
20(10~50)
40(10~80)
40(10~80)
40(10~100)
40(10~100)
dB(A)
45.4/39.8/37
45.4/39.8/37
48.0 /41.9/38
48.0 /41.9/38
47.7/43.2/39.0
47.7/43.2/39.0
Dimension (W×H×D)
mm
1140×270×775
Packing (W×H×D)
mm
1355×350×795
Net/Gross weight
kg
38/46.5
40/48
mm
Ф125
Ф125
Fresh Air Intake Size (round)
1200×300×865
1400×370×925
40/48
Ф125
Type
EXV
Design pressure
MPa
4.4/2.6
49/58
49/58
Ф125
Ф125
Ф125
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe diameter
Controller
40/48
R410A
Throttle
Refrigerant
piping
663/606/550/460
Dimension (W×H×D)
Refrigerant Type
Liquid
Drainage water pipe diameter
2.8
BTU
Indoor air flow (/Hi/Mi/Lo)
Indoor unit
2.2
Input
Capacity
Heating
kW
Controller
42VD024H113003011 42VD028H113003010 42VD030H113003010 42VD036H113003010 42VD048H113003010
Power supply
Capacity
Cooling
220-240V, 1Ph, 50Hz
V-ph-Hz
Drainage water pipe diameter
Wireless remote controller
Model
Power supply
Refrigerant Type
Liquid
Drainage water pipe diameter
42VD007H112013011 42VD009H112013011 42VD012H112013011 42VD016H112013011 42VD020H112013011 42VD024H112013011
Model
mm
ODФ32
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB,
and equivalent ref. piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* external static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
52
Specifications 50Hz
Specifications 60Hz
Model
42VD007H113003011 42VD009H113003011 42VD012H113003011 42VD016H113003011 42VD020H113003011
Power supply
kW
2.2
2.8
3.6
4.5
5.6
Btu/h
7500
9600
12300
15400
19100
Input
W
66
72
77
100
100
Rated current
A
0.24
0.24
0.28
0.48
0.48
Capacity
Cooling
kW
2.6
3.2
4
5
6.3
Btu/h
8900
10900
13600
17100
21500
Input
W
66
72
77
100
100
Rated current
A
0.24
0.24
0.28
0.48
0.48
Capacity
Heating
Indoor air flow (SH/H/M/L)
Indoor external static pressure (H)
Indoor noise level (H/M/L)
Indoor unit
208-230V~,1Ph, 60Hz
V- Ph-Hz
m3/h
614/597/514/429
763/811/684/575
763/811/684/575
CFM
588(30pa)/538/456/375 588/538/456/375
346/317/268/221
346/317/268/221
361/351/303/253
449/477/403/338
449/477/403/338
Pa
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
dB(A)
36/35/32
37/35/32
38.6/37.5/33.8
39/37.9/34
39/37.9/34
Dimension (W×H×D)
mm
740x210x500
740x210x500
740x210x500
960x210x500
960x210x500
Packing (W×H×D)
mm
870×285×525
870×285×525
870×285×525
1115×285×525
1115×285×525
Net/Gross weight
kg
22.5/26
22.5/26
Ф92
Ф92
Fresh Air intake hole diameter
mm
17.5/20
(Ф92)
Ф92
Refrigerant type
Ф92
R410A
Throttle
Type
EXV
Design pressure(H/L)
MPa
4.4/2.6
Refrigerant
piping
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф9.53
Gas
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф15.9
OD Ф25
mm
Controller
kW
7.1
8
9
11.2
14
Btu/h
24200
27300
30700
38200
47800
Input
W
125
133
134
378
352
Rated current
A
0.6
1
1
1.8
1.55
kW
8
9
10
12.5
15.5
Capacity
Cooling
Capacity
Heating
Btu/h
27300
30700
34100
42650
52900
Input
W
125
133
134
378
352
Rated current
A
0.6
1
1
1.8
1.55
Indoor air flow (SH/H/M/L)
Indoor external static pressure (H)
Indoor noise level (H/M/L)
Indoor unit
208-230V~,1Ph, 60Hz
V- Ph-Hz
m3/h
1127/1029/934/781 1388/1345/1165/1013 1388/1345/1165/1013 1851/1800/1556/1400 1745)/1905/1636/1400
CFM
663/606/550/460
817/792/686/596
817/792/686/596
1089/1059/916/824
1027/1121/963/824
Pa
10(10~30)
20(10~50)
20(10~50)
40(10~80)
40(10~100)
dB(A)
41.4/39/35
45.4/39.8/37
45.4/39.8/37
48.0 /41.9/38
47.7/43.2/39.0
Dimension (W×H×D)
mm
1180x210x500
1180×270×775
1180×270×775
1180×270×775
1240×300×865
Packing (W×H×D)
mm
1335×285×525
1355×350×795
1355×350×795
1355×350×795
1400×375×925
Net/Gross weight
kg
28/31.5
38/46.5
40/48
40/48
49/58
mm
Ф92
Ф125
Ф125
Ф125
Ф125
Fresh Air intake hole diameter
Refrigerant type
R410A
Throttle
Type
EXV
Design pressure(H/L)
MPa
4.4/2.6
Refrigerant
piping
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Controller
mm
OD Ф25
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB,
and equivalent ref. piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* external static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
51
3.6
4.5
5.6
7.1
24200
7500
9600
12300
15400
19100
W
68
68
72
80
80
105
Rated current
A
0.36
0.36
0.39
0.43
0.43
0.56
kW
2.6
3.2
4
5
6.3
8.0
BTU
8900
10900
13600
17100
21500
27300
Input
W
65
65
69
80
80
105
Rated current
A
0.36
0.36
0.39
0.43
0.43
0.56
m3/h
588/538/456/375
588/538/456/375
614/597/514/429
763/811/684/575
763/811/684/575 1127/1029/934/781
CFM
346/317/268/221
346/317/268/221
361/351/303/253
449/477/403/338
449/477/403/338
Pa
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
10(10~30)
dB(A)
36/35/32
37/35/32
38.6/37.5/33.8
39/37.9/34
39/37.9/34
41.4/39/35
Static pressure (Min.~Max.)
Sound level (sound pressure)
mm
740*210*500
960*210*500
1180*210*500
Packing (W×H×D)
mm
870*285*525
1115*285*525
1335*285*525
Net/Gross weight
kg
17.5/21
17.5/21
17.5/21
22.5/26
22.5/26
28/31.5
mm
Ф92
Ф92
Ф92
Ф92
Ф92
Ф92
Fresh Air Intake Size (round)
R410A
Throttle
Type
EXV
Design pressure
MPa
4.4/2.6
Refrigerant
piping
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Ф9.53
Ф9.53
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
Ф15.9
Ф15.9
mm
OD Ф25
Wireless controller
42VD028H112003010 42VD030H112003010 42VD034H112003010 42VD036H112003010 42VD042H112003010 42VD048H112003010
Model
Power supply
14
327
355
355
1.8
1.9
1.9
11
12.5
13.5
15.5
8
9
10
11.2
BTU
27300
30700
38200
47800
Input
W
231
231
327
Rated current
A
1
1
1.8
kW
9
10
BTU
30700
34100
42650
52900
Input
W
231
231
327
327
355
355
Rated current
A
1
1
1.8
1.8
1.9
1.9
Indoor air flow (/Hi/Mi/Lo)
Static pressure (Min.~Max.)
Sound level (sound pressure)
Indoor unit
12.5
kW
Capacity
Heating
220-240V, 1Ph, 50Hz
V-ph-Hz
Capacity
Cooling
m3/h
CFM
1388/1345/1165/1013 1388/1345/1165/1013 1851/1800/1556/1400 1851/1800/1556/1400 1745/1905/1636/1400 1745/1905/1636/1400
817/792/686/596
817/792/686/596 1089/1059/916/824 1089/1059/916/824 1027/1121/963/824 1027/1121/963/824
Pa
20(10~50)
20(10~50)
40(10~80)
40(10~80)
40(10~100)
40(10~100)
dB(A)
45.4/39.8/37
45.4/39.8/37
48.0 /41.9/38
48.0 /41.9/38
47.7/43.2/39.0
47.7/43.2/39.0
Dimension (W×H×D)
mm
1140×270×775
Packing (W×H×D)
mm
1355×350×795
Net/Gross weight
kg
38/46.5
40/48
mm
Ф125
Ф125
Fresh Air Intake Size (round)
1200×300×865
1400×370×925
40/48
Ф125
Type
EXV
Design pressure
MPa
4.4/2.6
49/58
49/58
Ф125
Ф125
Ф125
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe diameter
Controller
40/48
R410A
Throttle
Refrigerant
piping
663/606/550/460
Dimension (W×H×D)
Refrigerant Type
Liquid
Drainage water pipe diameter
2.8
BTU
Indoor air flow (/Hi/Mi/Lo)
Indoor unit
2.2
Input
Capacity
Heating
kW
Controller
42VD024H113003011 42VD028H113003010 42VD030H113003010 42VD036H113003010 42VD048H113003010
Power supply
Capacity
Cooling
220-240V, 1Ph, 50Hz
V-ph-Hz
Drainage water pipe diameter
Wireless remote controller
Model
Power supply
Refrigerant Type
Liquid
Drainage water pipe diameter
42VD007H112013011 42VD009H112013011 42VD012H112013011 42VD016H112013011 42VD020H112013011 42VD024H112013011
Model
mm
ODФ32
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB,
and equivalent ref. piping: 26.25ft. (8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* external static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
52
High Static Pressure Duct
Specifications 60Hz
Auto Restart
Anti-Cold Air Function
Auto Addressing
Connectable To Duct
Follow Me
Wireless remote
controller
Model
42VD024H113011010 42VD028H113011010 42VD030H113011010 42VD038H113011010 42VD048H113011010 42VD054H113011010
Power supply
kW
7.1
8
9
11.2
14
16
BTU
24200
27300
30700
38200
47800
51200
Input
W
414
402
409
409
527
532
Rated current
A
1.9
1.9
2.01
2.03
2.31
2.2
Capacity
Cooling
kW
8
9
10
12.5
16
16.5
BTU
27300
30700
34100
42700
54600
56400
Input
W
414
402
409
409
527
532
Rated current
A
1.9
1.9
2.01
2.01
2.31
2.2
3
m /h
1720/1532/1338
1690/1560/1320
2252/2030/1610
2198/1978/1570
2969/2694/2469
2969/2694/2469
CFM
1012/902/788
994/918/777
1326/1195/948
1294/1164/924
1746/1586/1453
1746/1586/1453
Pa
25(25~ 196)
37(37~ 196)
37(37~ 196)
50(50~ 196)
50(50~ 196)
50(50~ 196)
dB(A)
48/46/44.5
48/46/44.5
52/49/47
52/49/47
53/50/48
54/52/50
Capacity
Heating
Flexible duct design
Indoor air flow (/Hi/Mi/Lo)
Four speed fan motor (medium high speed as an option only for 71~160 model)
External static pressure can be up to 196Pa (71~160 models) or 280Pa (200~450 models).
Static pressure (Min.~Max.)
Sound level (sound pressure)
Indoor unit
the longest distance
of air supply is 14m
Min.
420mm
450mm
mm
Packing (W×H×D)
mm
1090×440×768
Net/Gross weight
kg
46.5/52
46.5/52
INDOOR UNIT
The max distance of air supply is about 45.9ft.(14m) while the height of air supply is about 21.3ft.(6.5m).
With 16-17/32in(420mm) thickness body, the minimum distance above the ceiling is 17-23/32in(450mm).
Design pressure
mm
Ф9.53
Gas side
mm
Ф15.9
42VD070H113011010 42VD085H113011010 42VD096H113011010 42VD135H113011010 42VD150H113011010
Standard wireless remote controller WL-12-CM, and wired remote controller WR-29B-CM is as an option.
The display board is connected with the E-box in factory, easier trouble-shooting by LED display.
Easy access filters both in rear & bottom
Standard functional port such as remote on/off dry contact.
Heating
kW
20
25
28
40
45
BTU
68200
85300
95500
136500
153500
Input
W
1800
1800
1800
1600
1600
Rated current
A
6.6
6.6
6.6
7.5
7.5
kW
22.5
26
31.5
45
50
BTU
76800
88700
107500
153580
170650
Input
W
1800
1800
1800
1600
1600
Rated current
A
6.6
6.6
6.6
7.5
7.5
3
m /h
4700/4100/3599
4700/4100/3599
4700/4100/3599
7180/6150/4600
7180/6150/4600
CFM
2766/2413/2118
2766/2413/2118
2766/2413/2118
4226/3620/2708
4226/3620/2708
Pa
140(50~250)
140(50~250)
160(50~250)
200(50~280)
200(50~280)
dB(A)
59/55/52
59/55/52
59/55/52
61/59/56
61/59/56
Indoor air flow (/Hi/Mi/Lo)
Static pressure (Min.~Max.)
Sound level (sound pressure)
Indoor unit
208-230V~, 1Ph, 60Hz
V-ph-Hz
Capacity
Flexible control and convenient for maintenance
mm
Wireless remote controller
Capacity
The EXV is fixed inside the indoor unit (for 71~450 model), no need extra connection.
Standard filter placed in an aluminum frame, which is removable downward from bottom.
Flange for air in/outlet duct connection is standard.
Ф15.9
OD Ф32
Model
Convenient installation
Dimension (W×H×D)
mm
Packing (W×H×D)
mm
Net/Gross weight
kg
1425×500×928
Double-skin drainage pan
115/129
29-17/32in.(750mm)
Optional drain pumps with 29-17/32in.(750mm)
pumphead.
53
235/250
EXV
Type
Design pressure
4.4/2.6
MPa
Liquid side
mm
Ф9.53×2
Ф12.7×2
Gas side
mm
Ф15.9×2
Ф22.2×2
Drainage water pipe diameter
OD Ф32
mm
Controller
ceiling
2095×800×964
115/129
R410A
Throttle
Refrigerant
piping
1970×668×902.5
1509×550×990
115/129
Refrigerant Type
Option
69.5/76
Ф9.53
Controller
Cooling
1436×450×768
68/70
4.4/2.6
MPa
Power supply
Four speed fan motor(model 71 to 160)
50/56.5
EXV
Liquid side
Added flexibility with four speed fan
952×420×690
1090×440×768
50/56.5
Type
Drainage water pipe diameter
Air return
1300×420×691
R410A
Throttle
Refrigerant
piping
INDOOR UNIT
Air supply
Dimension (W×H×D)
952×420×690
Refrigerant Type
Fresh air in take
The height of air
supply is 6.5m
208-230V~, 1Ph, 60Hz
V-ph-Hz
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)
Double-skin drainage pan, double production for
your ceiling.(for 71~450 model)
WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. Piping:26.25ft(8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
54
High Static Pressure Duct
Specifications 60Hz
Auto Restart
Anti-Cold Air Function
Auto Addressing
Connectable To Duct
Follow Me
Wireless remote
controller
Model
42VD024H113011010 42VD028H113011010 42VD030H113011010 42VD038H113011010 42VD048H113011010 42VD054H113011010
Power supply
kW
7.1
8
9
11.2
14
16
BTU
24200
27300
30700
38200
47800
51200
Input
W
414
402
409
409
527
532
Rated current
A
1.9
1.9
2.01
2.03
2.31
2.2
Capacity
Cooling
kW
8
9
10
12.5
16
16.5
BTU
27300
30700
34100
42700
54600
56400
Input
W
414
402
409
409
527
532
Rated current
A
1.9
1.9
2.01
2.01
2.31
2.2
3
m /h
1720/1532/1338
1690/1560/1320
2252/2030/1610
2198/1978/1570
2969/2694/2469
2969/2694/2469
CFM
1012/902/788
994/918/777
1326/1195/948
1294/1164/924
1746/1586/1453
1746/1586/1453
Pa
25(25~ 196)
37(37~ 196)
37(37~ 196)
50(50~ 196)
50(50~ 196)
50(50~ 196)
dB(A)
48/46/44.5
48/46/44.5
52/49/47
52/49/47
53/50/48
54/52/50
Capacity
Heating
Flexible duct design
Indoor air flow (/Hi/Mi/Lo)
Four speed fan motor (medium high speed as an option only for 71~160 model)
External static pressure can be up to 196Pa (71~160 models) or 280Pa (200~450 models).
Static pressure (Min.~Max.)
Sound level (sound pressure)
Indoor unit
the longest distance
of air supply is 14m
Min.
420mm
450mm
mm
Packing (W×H×D)
mm
1090×440×768
Net/Gross weight
kg
46.5/52
46.5/52
INDOOR UNIT
The max distance of air supply is about 45.9ft.(14m) while the height of air supply is about 21.3ft.(6.5m).
With 16-17/32in(420mm) thickness body, the minimum distance above the ceiling is 17-23/32in(450mm).
Design pressure
mm
Ф9.53
Gas side
mm
Ф15.9
42VD070H113011010 42VD085H113011010 42VD096H113011010 42VD135H113011010 42VD150H113011010
Standard wireless remote controller WL-12-CM, and wired remote controller WR-29B-CM is as an option.
The display board is connected with the E-box in factory, easier trouble-shooting by LED display.
Easy access filters both in rear & bottom
Standard functional port such as remote on/off dry contact.
Heating
kW
20
25
28
40
45
BTU
68200
85300
95500
136500
153500
Input
W
1800
1800
1800
1600
1600
Rated current
A
6.6
6.6
6.6
7.5
7.5
kW
22.5
26
31.5
45
50
BTU
76800
88700
107500
153580
170650
Input
W
1800
1800
1800
1600
1600
Rated current
A
6.6
6.6
6.6
7.5
7.5
3
m /h
4700/4100/3599
4700/4100/3599
4700/4100/3599
7180/6150/4600
7180/6150/4600
CFM
2766/2413/2118
2766/2413/2118
2766/2413/2118
4226/3620/2708
4226/3620/2708
Pa
140(50~250)
140(50~250)
160(50~250)
200(50~280)
200(50~280)
dB(A)
59/55/52
59/55/52
59/55/52
61/59/56
61/59/56
Indoor air flow (/Hi/Mi/Lo)
Static pressure (Min.~Max.)
Sound level (sound pressure)
Indoor unit
208-230V~, 1Ph, 60Hz
V-ph-Hz
Capacity
Flexible control and convenient for maintenance
mm
Wireless remote controller
Capacity
The EXV is fixed inside the indoor unit (for 71~450 model), no need extra connection.
Standard filter placed in an aluminum frame, which is removable downward from bottom.
Flange for air in/outlet duct connection is standard.
Ф15.9
OD Ф32
Model
Convenient installation
Dimension (W×H×D)
mm
Packing (W×H×D)
mm
Net/Gross weight
kg
1425×500×928
Double-skin drainage pan
115/129
29-17/32in.(750mm)
Optional drain pumps with 29-17/32in.(750mm)
pumphead.
53
235/250
EXV
Type
Design pressure
4.4/2.6
MPa
Liquid side
mm
Ф9.53×2
Ф12.7×2
Gas side
mm
Ф15.9×2
Ф22.2×2
Drainage water pipe diameter
OD Ф32
mm
Controller
ceiling
2095×800×964
115/129
R410A
Throttle
Refrigerant
piping
1970×668×902.5
1509×550×990
115/129
Refrigerant Type
Option
69.5/76
Ф9.53
Controller
Cooling
1436×450×768
68/70
4.4/2.6
MPa
Power supply
Four speed fan motor(model 71 to 160)
50/56.5
EXV
Liquid side
Added flexibility with four speed fan
952×420×690
1090×440×768
50/56.5
Type
Drainage water pipe diameter
Air return
1300×420×691
R410A
Throttle
Refrigerant
piping
INDOOR UNIT
Air supply
Dimension (W×H×D)
952×420×690
Refrigerant Type
Fresh air in take
The height of air
supply is 6.5m
208-230V~, 1Ph, 60Hz
V-ph-Hz
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)
Double-skin drainage pan, double production for
your ceiling.(for 71~450 model)
WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. Piping:26.25ft(8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m) (horizontal).
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
54
Specifications 50Hz
Model
42VD028H112011010 42VD032H112011010 42VD036H112011010 42VD036H112011010 42VD048H112011010 42VD054H112011010
Power supply
Cooling
Input
Rated current
Capacity
Heating
kW
7.1
8
9
11.2
14
16
BTU
24200
27300
30700
38200
47800
51200
W
240
240
398
518
648
873
A
1.1
1.1
1.8
2.3
2.7
3.6
kW
8
9
10
12.5
16
17
BTU
27300
30700
34100
42700
54600
56400
Input
W
240
240
398
518
648
873
Rated current
A
1.1
1.1
1.8
2.3
2.7
3.6
3
m /h
1443/1361/1218
1416/1338/1220
1915/1741/1518
2116/1936/1520
3000/2618/2226
3620/2044/2744
CFM
849/801/717
883/788/718
1148/1025/893
1426/1140/895
1766/1541/1310
2131/1792/1615
Pa
40(30~ 196)
40(30~ 196)
40(30~ 196)
50(30~ 196)
50(30~ 196)
50(30~ 196)
dB(A)
48/46/44
48/46/44.5
52/49/47
52/49/47
53/50/48
54/52/50
Indoor air flow (Hi/Mi/Lo)
Indoor external static pressure
Indoor noise level (Sound pressure)(Hi/Mi/Lo)
Indoor unit
220-240V, 1Ph, 50Hz
V-Ph-Hz
Capacity
Dimension (W×H×D)
mm
952×420×690
1200×400×600
Packing (W×H×D)
mm
1090×440×768
1436×450×768
Net/Gross weight
Kg
45/50
45/50
46.5/52.4
50.6/56
70/77.5
EXV
Type
Design pressure
Refrigerant
piping
68/70
R410A
Refrigerant type
Throttle type
mm
Ф9.53
Gas side
mm
Ф15.9
Ф9.53
Model
Capacity
Cooling
Input
Rated current
20
25
28
40
45
56
BTU
68200
85300
95500
136500
153500
170600
W
1800
1800
1800
2700
2700
3400
15.5
A
6.6
6.6
6.6
12.5
12.5
22.5
26
31.5
45
50
63
BTU
76800
88700
107500
153500
170600
215000
Input
W
1800
1800
1800
2700
2700
3400
Rated current
A
6.6
6.6
6.6
12.5
12.5
15.5
m3/h
4700/4100/3599
4700/4100/3599
4700/4100/3599
7472/6072/4995
7472/6072/4995
9550/7950/6600
CFM
2766/2413/2118
2766/2413/2118
2766/2413/2118
4395/3572/2938
4395/3572/2938
5618/4676/3882
Pa
140(50~250)
140(50~250)
160(50~250)
200(50~280)
200(50~280)
200(50~280)
dB(A)
59/55/52
59/55/52
59/55/52
61/59/56
61/59/56
63/60/57
Indoor air flow (Hi/Mi/Lo)
Indoor external static pressure
Indoor noise level (Sound pressure)(Hi/Mi/Lo)
Indoor unit
kW
kW
Capacity
Heating
220-240V, 1Ph, 50Hz
V-Ph-Hz
Dimension (W×H×D)
mm
1425×500×928
Packing (W×H×D)
mm
1509×550×990
Net/Gross weight
Kg
115/129
115/129
1970×668×902.5
2095×800×964
115/129
232/245
Throttle type
Type
EXV
Design pressure
MPa
4.4/2.6
Refrigerant
piping
232/245
235/250
R410A
Refrigerant type
mm
Ф9.53×2
Ф12.7×2
Ф12.7×2
Ф15.9×2
Gas side
mm
Ф15.9×2
Ф28.6×2
Ф28.6×2
Ф28.6×2
mm
ODФ32
Wireless Controller
Controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)
WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. Piping:26.25ft(8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m) (horizontal).
Follow Me
LED
LED Display
DISPLAY
Panel with LED display
The front panel and display panel have different colors to choose: white and brown to big panel, blue and
brown for small panel, and the other colors can be customized according to the customers’ demands.
conditioner in the center of the ceiling is impossible
due to a structure such as one lighting
The unit can be installed either horizontally on the
ceiling or vertically against the wall.
Low noise, creates quiet and comfortable environment
Drop ceiling
>20
198mm
Air Outlet
Slim and sleek design starting at just 66lbs.(30kg) in weight means quick,easy & neat installation.
Low noise operation, lowest to 36dB(A)
Auto swing and wide angle air flow
Auto Swing & Wide-angle Airflow
Liquid side
Drainage pipe diameter
Anti-Cold Air Function
It is especially useful when installation of an air
42VD070H112011010 42VD085H112011010 42VD096H112011010 42VD135H112011010 42VD150H112011010 42VD190H112011010
Power supply
Auto Addressing
the ceiling even if the ceiling is very narrow
Wireless Controller
Controller
Cleanable Panel
The ceiling type can be easily installed into a corner of
Ф15.9
ODФ32
mm
Auto Restart
Convenient for installation
4.4/2.6
MPa
Liquid side
Drainage pipe diameter
Ceiling & Floor
1.The unit has auto horizontal swing and auto vertical swing function,
which supplies more even and comfortable airflow.
2.Three airflow speed: high/middle/low, double air guides.
3.Adoption of the electronic expansion valve, ensure precise flow
control, as well lower modulation noise when EXV operating.
4.Smoother airflow with less turbulence. Due to the multiple-blade fan
and the air guide design, the airflow is getting smoother and more
comfortable.
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
55
56
Specifications 50Hz
Model
42VD028H112011010 42VD032H112011010 42VD036H112011010 42VD036H112011010 42VD048H112011010 42VD054H112011010
Power supply
Cooling
Input
Rated current
Capacity
Heating
kW
7.1
8
9
11.2
14
16
BTU
24200
27300
30700
38200
47800
51200
W
240
240
398
518
648
873
A
1.1
1.1
1.8
2.3
2.7
3.6
kW
8
9
10
12.5
16
17
BTU
27300
30700
34100
42700
54600
56400
Input
W
240
240
398
518
648
873
Rated current
A
1.1
1.1
1.8
2.3
2.7
3.6
3
m /h
1443/1361/1218
1416/1338/1220
1915/1741/1518
2116/1936/1520
3000/2618/2226
3620/2044/2744
CFM
849/801/717
883/788/718
1148/1025/893
1426/1140/895
1766/1541/1310
2131/1792/1615
Pa
40(30~ 196)
40(30~ 196)
40(30~ 196)
50(30~ 196)
50(30~ 196)
50(30~ 196)
dB(A)
48/46/44
48/46/44.5
52/49/47
52/49/47
53/50/48
54/52/50
Indoor air flow (Hi/Mi/Lo)
Indoor external static pressure
Indoor noise level (Sound pressure)(Hi/Mi/Lo)
Indoor unit
220-240V, 1Ph, 50Hz
V-Ph-Hz
Capacity
Dimension (W×H×D)
mm
952×420×690
1200×400×600
Packing (W×H×D)
mm
1090×440×768
1436×450×768
Net/Gross weight
Kg
45/50
45/50
46.5/52.4
50.6/56
70/77.5
EXV
Type
Design pressure
Refrigerant
piping
68/70
R410A
Refrigerant type
Throttle type
mm
Ф9.53
Gas side
mm
Ф15.9
Ф9.53
Model
Capacity
Cooling
Input
Rated current
20
25
28
40
45
56
BTU
68200
85300
95500
136500
153500
170600
W
1800
1800
1800
2700
2700
3400
15.5
A
6.6
6.6
6.6
12.5
12.5
22.5
26
31.5
45
50
63
BTU
76800
88700
107500
153500
170600
215000
Input
W
1800
1800
1800
2700
2700
3400
Rated current
A
6.6
6.6
6.6
12.5
12.5
15.5
m3/h
4700/4100/3599
4700/4100/3599
4700/4100/3599
7472/6072/4995
7472/6072/4995
9550/7950/6600
CFM
2766/2413/2118
2766/2413/2118
2766/2413/2118
4395/3572/2938
4395/3572/2938
5618/4676/3882
Pa
140(50~250)
140(50~250)
160(50~250)
200(50~280)
200(50~280)
200(50~280)
dB(A)
59/55/52
59/55/52
59/55/52
61/59/56
61/59/56
63/60/57
Indoor air flow (Hi/Mi/Lo)
Indoor external static pressure
Indoor noise level (Sound pressure)(Hi/Mi/Lo)
Indoor unit
kW
kW
Capacity
Heating
220-240V, 1Ph, 50Hz
V-Ph-Hz
Dimension (W×H×D)
mm
1425×500×928
Packing (W×H×D)
mm
1509×550×990
Net/Gross weight
Kg
115/129
115/129
1970×668×902.5
2095×800×964
115/129
232/245
Throttle type
Type
EXV
Design pressure
MPa
4.4/2.6
Refrigerant
piping
232/245
235/250
R410A
Refrigerant type
mm
Ф9.53×2
Ф12.7×2
Ф12.7×2
Ф15.9×2
Gas side
mm
Ф15.9×2
Ф28.6×2
Ф28.6×2
Ф28.6×2
mm
ODФ32
Wireless Controller
Controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)
WB,and outdoor temperature: 95°F(35°C)DB,equivalent ref. Piping:26.25ft(8m) (horizontal).
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m) (horizontal).
Follow Me
LED
LED Display
DISPLAY
Panel with LED display
The front panel and display panel have different colors to choose: white and brown to big panel, blue and
brown for small panel, and the other colors can be customized according to the customers’ demands.
conditioner in the center of the ceiling is impossible
due to a structure such as one lighting
The unit can be installed either horizontally on the
ceiling or vertically against the wall.
Low noise, creates quiet and comfortable environment
Drop ceiling
>20
198mm
Air Outlet
Slim and sleek design starting at just 66lbs.(30kg) in weight means quick,easy & neat installation.
Low noise operation, lowest to 36dB(A)
Auto swing and wide angle air flow
Auto Swing & Wide-angle Airflow
Liquid side
Drainage pipe diameter
Anti-Cold Air Function
It is especially useful when installation of an air
42VD070H112011010 42VD085H112011010 42VD096H112011010 42VD135H112011010 42VD150H112011010 42VD190H112011010
Power supply
Auto Addressing
the ceiling even if the ceiling is very narrow
Wireless Controller
Controller
Cleanable Panel
The ceiling type can be easily installed into a corner of
Ф15.9
ODФ32
mm
Auto Restart
Convenient for installation
4.4/2.6
MPa
Liquid side
Drainage pipe diameter
Ceiling & Floor
1.The unit has auto horizontal swing and auto vertical swing function,
which supplies more even and comfortable airflow.
2.Three airflow speed: high/middle/low, double air guides.
3.Adoption of the electronic expansion valve, ensure precise flow
control, as well lower modulation noise when EXV operating.
4.Smoother airflow with less turbulence. Due to the multiple-blade fan
and the air guide design, the airflow is getting smoother and more
comfortable.
3. Sound Level is measured 4.59ft. (1.4m) below the unit.
* Specifications are subject to change without prior notice for product improvement.
55
56
Specifications 60Hz
Specifications 60Hz
Model
42VF012H113000010 42VF016H113000010 42VF020H113000010 42VF024H113000010 42VF028H113000010
Power supply
kW
3.6
4.5
42VF030H113000010
Power supply
208-230V-1Ph~60Hz
V- Ph-Hz
Model
5.6
7.1
V- Ph-Hz
8
42VF036H113000010
42VF048H113000010
42VF054H113000010
208-230V-1Ph~60Hz
kW
9
11.2
14
16
Btu/h
30700
38200
47800
54600
Capacity
Capacity
Btu/h
12300
15400
19100
24200
27300
Cooling
Cooling
Input
W
50
148
148
148
183
Input
W
183
245
245
378
Rated current
A
0.55
0.55
0.55
0.57
0.6
Rated current
A
0.6
0.83
0.83
1.75
kW
4
5
6.3
8
9
kW
10
12.5
15
18
Btu/h
34100
42700
52900
61400
Capacity
Capacity
Btu/h
13600
17100
21500
27300
30700
Heating
Heating
Input
W
50
148
148
148
183
Input
W
183
245
245
378
Rated current
A
0.55
0.55
0.55
0.57
0.6
Rated current
A
0.6
0.83
0.83
1.75
m3/h
600/480/400
750/650/550
750/650/550
750/650/550
1200/900/700
m3/h
1200/900/700
1980/1860/1730
1980/1860/1730
2300/2100/1800
CFM
706/529.7/412
1165/1095/1018
1165/1095/1018
1354/1236/1060
dB(A)
45/43/40
47/45/42
47/45/42
52
Dimension (W×H×D)
mm
1280×203×660
1670×244×680
1670×244×680
1670x285x680
Packing (W×H×D)
mm
1379x296x744
1764x329x760
1764x329x760
1775x377x760
Net/Gross weight
kg
34.5/41
54/59
54/59
57.5/63.5
R410A
R410A
R410A
R410A
Indoor air flow (H/M/L)
Indoor air flow (H/M/L)
CFM
353/282.5/235.4
441.1/382.6/323.7
441.1/382.6/323.7
441.1/382.6/323.7
706/529.7/412
dB(A)
40/38/36
43/41/38
43/41/38
43/41/38
45/43/40
Dimension (W×H×D)
mm
990×203×660
990×203×660
990×203×660
990×203×660
1280×203×660
Packing (W×H×D)
mm
1089x296x744
1089x296x744
1089x296x744
1089x296x744
1379x296x744
Net/Gross weight
kg
26/32
28/34
28/34
28/34
34.5/41
R410A
R410A
R410A
R410A
R410A
Indoor noise level (H/M/L)
Indoor unit
Refrigerant type
Throttle
Type
EXV
EXV
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Ф6.35
Ф6.35
Ф9.52
Ф9.52
Ф9.52
Liquid side
Gas side
Drainage water pipe diameter
Ф12.7
in.(mm)
in.(mm)
OD Ф25
OD Ф25
Ф15.9
Ф15.9
Ф15.9
OD Ф25
OD Ф25
OD Ф25
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,
and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal).
3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance.
Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.
Specifications are subject to change without prior notice for product improvement.
*
57
Indoor unit
Refrigerant type
Throttle
Type
EXV
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Ф9.52
Ф9.52
Ф9.52
Ф9.52
in.(mm)
Ф15.9
Ф15.9
Ф15.9
Ф15.9
in.(mm)
OD Ф25
OD Ф25
OD Ф25
OD Ф25
Liquid side
Refrigerant piping
Refrigerant piping
Controller
Indoor noise level (H/M/L)
Gas side
Drainage water pipe diameter
Controller
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,
and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal).
3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance.
Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.
Specifications are subject to change without prior notice for product improvement.
*
58
Specifications 60Hz
Specifications 60Hz
Model
42VF012H113000010 42VF016H113000010 42VF020H113000010 42VF024H113000010 42VF028H113000010
Power supply
kW
3.6
4.5
42VF030H113000010
Power supply
208-230V-1Ph~60Hz
V- Ph-Hz
Model
5.6
7.1
V- Ph-Hz
8
42VF036H113000010
42VF048H113000010
42VF054H113000010
208-230V-1Ph~60Hz
kW
9
11.2
14
16
Btu/h
30700
38200
47800
54600
Capacity
Capacity
Btu/h
12300
15400
19100
24200
27300
Cooling
Cooling
Input
W
50
148
148
148
183
Input
W
183
245
245
378
Rated current
A
0.55
0.55
0.55
0.57
0.6
Rated current
A
0.6
0.83
0.83
1.75
kW
4
5
6.3
8
9
kW
10
12.5
15
18
Btu/h
34100
42700
52900
61400
Capacity
Capacity
Btu/h
13600
17100
21500
27300
30700
Heating
Heating
Input
W
50
148
148
148
183
Input
W
183
245
245
378
Rated current
A
0.55
0.55
0.55
0.57
0.6
Rated current
A
0.6
0.83
0.83
1.75
m3/h
600/480/400
750/650/550
750/650/550
750/650/550
1200/900/700
m3/h
1200/900/700
1980/1860/1730
1980/1860/1730
2300/2100/1800
CFM
706/529.7/412
1165/1095/1018
1165/1095/1018
1354/1236/1060
dB(A)
45/43/40
47/45/42
47/45/42
52
Dimension (W×H×D)
mm
1280×203×660
1670×244×680
1670×244×680
1670x285x680
Packing (W×H×D)
mm
1379x296x744
1764x329x760
1764x329x760
1775x377x760
Net/Gross weight
kg
34.5/41
54/59
54/59
57.5/63.5
R410A
R410A
R410A
R410A
Indoor air flow (H/M/L)
Indoor air flow (H/M/L)
CFM
353/282.5/235.4
441.1/382.6/323.7
441.1/382.6/323.7
441.1/382.6/323.7
706/529.7/412
dB(A)
40/38/36
43/41/38
43/41/38
43/41/38
45/43/40
Dimension (W×H×D)
mm
990×203×660
990×203×660
990×203×660
990×203×660
1280×203×660
Packing (W×H×D)
mm
1089x296x744
1089x296x744
1089x296x744
1089x296x744
1379x296x744
Net/Gross weight
kg
26/32
28/34
28/34
28/34
34.5/41
R410A
R410A
R410A
R410A
R410A
Indoor noise level (H/M/L)
Indoor unit
Refrigerant type
Throttle
Type
EXV
EXV
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Ф6.35
Ф6.35
Ф9.52
Ф9.52
Ф9.52
Liquid side
Gas side
Drainage water pipe diameter
Ф12.7
in.(mm)
in.(mm)
OD Ф25
OD Ф25
Ф15.9
Ф15.9
Ф15.9
OD Ф25
OD Ф25
OD Ф25
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,
and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal).
3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance.
Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.
Specifications are subject to change without prior notice for product improvement.
*
57
Indoor unit
Refrigerant type
Throttle
Type
EXV
EXV
EXV
EXV
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.4/2.6
4.4/2.6
Ф9.52
Ф9.52
Ф9.52
Ф9.52
in.(mm)
Ф15.9
Ф15.9
Ф15.9
Ф15.9
in.(mm)
OD Ф25
OD Ф25
OD Ф25
OD Ф25
Liquid side
Refrigerant piping
Refrigerant piping
Controller
Indoor noise level (H/M/L)
Gas side
Drainage water pipe diameter
Controller
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,
and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal).
3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance.
Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.
Specifications are subject to change without prior notice for product improvement.
*
58
Specifications 50Hz
Wall-mounted
Power supply
Capacity
Cooling
220~240-1-50
220~240-1-50
220~240-1-50
4.5
5.6
7.1
8
12300
15400
19100
24200
27300
34
125
125
125
143
Rated current
A
0.55
0.55
0.55
0.57
0.6
kW
4
5
6
8
9
BTU
13600
17100
21500
27300
30700
Input
W
34
125
125
125
143
Rated current
A
0.55
0.55
0.55
0.57
0.6
m3/h
650/570/500
800/600/500
800/600/500
800/600/500
1200/900/700
CFM
383/335/294
471/353/294
471/353/294
471/353/294
706/530/412
dB(A)
40/38/36
43/41/38
43/41/38
43/41/38
45/43/40
Dimension (W×H×D)
mm
990×660×206
990×660×206
990×660×206
990×660×206
1280×660×206
Packing (W×H×D)
mm
1090×745×297
1090×745×297
1090×745×297
1090×745×297
1380×745×297
Net/Gross weight
kg
26/32
28/34
28/34
28/34
34.5/41
R410A
R410A
R410A
R410A
R410A
MPa
4.2/2.5
4.2/2.5
4.2/2.5
4.2/2.5
4.2/2.5
Liquid side
mm
Ф6.35
Ф6.35
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф12.7
Ф12.7
Ф15.9
Ф15.9
Ф15.9
mm
ODФ16
ODФ16
ODФ16
ODФ16
ODФ16
Type
Design pressure
Refrigerant
piping
220~240-1-50
3.6
W
Sound level (sound pressure)
Refrigerant
220~240-1-50
kW
BTU
Indoor air flow (Hi/Mi/Lo)
Indoor unit
V-ph-Hz
Input
Capacity
Heating
Drainage water pipe diameter
Controller
Wireless controller
42VF030H112000010
Sale Model
Power supply
Capacity
Cooling
42VF054H112000010
V-ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
kW
9
11.2
14
16
30700
38200
47800
54600
W
143
182
182
300
Rated current
A
0.6
0.83
0.83
1.41
kW
10
12.5
15.5
15.5
BTU
34100
42700
52900
52900
W
143
182
182
300
Rated current
Indoor air flow (Hi/Mi/Lo)
Sound level (sound pressure)
Refrigerant
42VF048H112000010
BTU
Input
Indoor unit
42VF036H112000010
Input
Capacity
Heating
A
0.6
0.83
0.83
1.41
m3/h
1200/900/700
1980/1860/1730
1980/1860/1730
1980/1860/1730
CFM
706/530/412
1165/1095/1018
1165/1095/1018
1165/1095/1018
dB(A)
45/43/40
47/45/42
47/45/42
47/45/42
1670×680×244
1670×680×244
1670×680×244
Dimension (W×H×D)
mm
Packing (W×H×D)
mm
1380×745×297
1765×760×330
1765×760×330
1765×760×330
Net/Gross weight
kg
34.5/41
54/59
54/59
57.5/63.5
Type
1280×660×206
R410A
R410A
R410A
R410A
MPa
4.2/2.5
4.2/2.5
4.2/2.5
4.2/2.5
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe diameter
mm
ODФ16
ODФ16
ODФ16
ODФ16
Design pressure
Refrigerant
piping
Controller
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,
and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal).
3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance.
Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.
Specifications are subject to change without prior notice for product improvement.
*
59
Auto Restart
42VF012H112000010 42VF016H112000010 42VF020H112000010 42VF024H112000010 42VF028H112000010
Sale Model
S type panel
Auto Addressing
R type panel
Cleanable Panel
Anti-Cold Air Function
Follow Me
LED Display
LED
DISPLAY
Panel with LED display
The front panel and display panel have different colors to choose: white and brown for big panel, blue and
brown for small panel.
Convenient installation
Multi-refrigerant outlet pipe method: left\right\rear, more
flexible for installation.
The EXV is built-in the indoor unit, compact size, longer the
connection pipe; Gas pipe: 18-27/64in.(468mm)/Liquid pipe:
21-21/32in.(550mm), more flexible for the installation.
Adopts new type fixing plate, which means easy to install and
stable.
Rear
Right
Left
Auto swing louver
Easy maintenance
auto swing louver function
ensures that the air
direction corresponds to
the mode selected.
The front panel can be removed for easy
maintenance access.
Open panel
1
2
Step
Swing
3
4
Optimal comfort through better flow control and quiet operations
The mechanical expansion valve offers 2,000-stage
element positions to ensure precise flow control and less
modulation noise when the EXV is operating for a quiet
and comfortable environment. Three air flow speeds: low,
medium and high; double air guides. Smoother airflow and
less turbulence is ensured by the multi-blade fan and the
air guide design.
60
Specifications 50Hz
Wall-mounted
Power supply
Capacity
Cooling
220~240-1-50
220~240-1-50
220~240-1-50
4.5
5.6
7.1
8
12300
15400
19100
24200
27300
34
125
125
125
143
Rated current
A
0.55
0.55
0.55
0.57
0.6
kW
4
5
6
8
9
BTU
13600
17100
21500
27300
30700
Input
W
34
125
125
125
143
Rated current
A
0.55
0.55
0.55
0.57
0.6
m3/h
650/570/500
800/600/500
800/600/500
800/600/500
1200/900/700
CFM
383/335/294
471/353/294
471/353/294
471/353/294
706/530/412
dB(A)
40/38/36
43/41/38
43/41/38
43/41/38
45/43/40
Dimension (W×H×D)
mm
990×660×206
990×660×206
990×660×206
990×660×206
1280×660×206
Packing (W×H×D)
mm
1090×745×297
1090×745×297
1090×745×297
1090×745×297
1380×745×297
Net/Gross weight
kg
26/32
28/34
28/34
28/34
34.5/41
R410A
R410A
R410A
R410A
R410A
MPa
4.2/2.5
4.2/2.5
4.2/2.5
4.2/2.5
4.2/2.5
Liquid side
mm
Ф6.35
Ф6.35
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф12.7
Ф12.7
Ф15.9
Ф15.9
Ф15.9
mm
ODФ16
ODФ16
ODФ16
ODФ16
ODФ16
Type
Design pressure
Refrigerant
piping
220~240-1-50
3.6
W
Sound level (sound pressure)
Refrigerant
220~240-1-50
kW
BTU
Indoor air flow (Hi/Mi/Lo)
Indoor unit
V-ph-Hz
Input
Capacity
Heating
Drainage water pipe diameter
Controller
Wireless controller
42VF030H112000010
Sale Model
Power supply
Capacity
Cooling
42VF054H112000010
V-ph-Hz
220~240-1-50
220~240-1-50
220~240-1-50
220~240-1-50
kW
9
11.2
14
16
30700
38200
47800
54600
W
143
182
182
300
Rated current
A
0.6
0.83
0.83
1.41
kW
10
12.5
15.5
15.5
BTU
34100
42700
52900
52900
W
143
182
182
300
Rated current
Indoor air flow (Hi/Mi/Lo)
Sound level (sound pressure)
Refrigerant
42VF048H112000010
BTU
Input
Indoor unit
42VF036H112000010
Input
Capacity
Heating
A
0.6
0.83
0.83
1.41
m3/h
1200/900/700
1980/1860/1730
1980/1860/1730
1980/1860/1730
CFM
706/530/412
1165/1095/1018
1165/1095/1018
1165/1095/1018
dB(A)
45/43/40
47/45/42
47/45/42
47/45/42
1670×680×244
1670×680×244
1670×680×244
Dimension (W×H×D)
mm
Packing (W×H×D)
mm
1380×745×297
1765×760×330
1765×760×330
1765×760×330
Net/Gross weight
kg
34.5/41
54/59
54/59
57.5/63.5
Type
1280×660×206
R410A
R410A
R410A
R410A
MPa
4.2/2.5
4.2/2.5
4.2/2.5
4.2/2.5
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe diameter
mm
ODФ16
ODФ16
ODФ16
ODФ16
Design pressure
Refrigerant
piping
Controller
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature: 80.6°F(27°C)DB,66.2°F(19°C)WB,
and outdoor temperature: 95°F(35°C)DB,equivalent ref. piping: 26.25ft. (8m) (horizontal) .
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB,
outdoor temperature: 44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft.(8m) (horizontal).
3. Floor standing :Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance, 3.28ft(1m) above the floor in vertical distance.
Ceiling mounted:Sound level is measured 3.28ft(1m) from air-outlet in horizontal distance,3.28ft(1m) from air-outlet in vertical distance.
Specifications are subject to change without prior notice for product improvement.
*
59
Auto Restart
42VF012H112000010 42VF016H112000010 42VF020H112000010 42VF024H112000010 42VF028H112000010
Sale Model
S type panel
Auto Addressing
R type panel
Cleanable Panel
Anti-Cold Air Function
Follow Me
LED Display
LED
DISPLAY
Panel with LED display
The front panel and display panel have different colors to choose: white and brown for big panel, blue and
brown for small panel.
Convenient installation
Multi-refrigerant outlet pipe method: left\right\rear, more
flexible for installation.
The EXV is built-in the indoor unit, compact size, longer the
connection pipe; Gas pipe: 18-27/64in.(468mm)/Liquid pipe:
21-21/32in.(550mm), more flexible for the installation.
Adopts new type fixing plate, which means easy to install and
stable.
Rear
Right
Left
Auto swing louver
Easy maintenance
auto swing louver function
ensures that the air
direction corresponds to
the mode selected.
The front panel can be removed for easy
maintenance access.
Open panel
1
2
Step
Swing
3
4
Optimal comfort through better flow control and quiet operations
The mechanical expansion valve offers 2,000-stage
element positions to ensure precise flow control and less
modulation noise when the EXV is operating for a quiet
and comfortable environment. Three air flow speeds: low,
medium and high; double air guides. Smoother airflow and
less turbulence is ensured by the multi-blade fan and the
air guide design.
60
Specifications 50Hz
Specifications 60Hz
Model
42VH007H113000101
Power supply
Input
Rated current
Capacity
Heating
Input
Rated current
Indoor air flow (H/M/L)
Indoor noise level (H/M/L)
Indoor unit
42VH012H113000101
42VH016H113000101
2.2
2.8
3.6
4.5
Btu/h
7500
9600
12300
15400
W
25
28
30
51
Input
A
0.14
0.14
0.14
0.2
Rated current
kW
2.4
3.2
4
5
Btu/h
8200
10900
13600
17100
W
25
28
30
51
A
0.14
0.14
0.14
0.2
m3/h
525/480/430
525/480/430
590/520/480
860/755/630
CFM
309/282.5/253
309/282.5/253
347/306/282.5
506/444/370.8
dB(A)
35/32/29
35/32/29
35/32/29
40/38/34
mm
915×230×290
915×230×290
915×230×290
1072×230×315
Packing (W×H×D)
mm
1020×315×390
1020×315×390
1020×315×390
1180×315×415
Net/Gross weight
kg
13/16.8
13/16.8
13/16.8
15.1/19.5
Type
S Type
S Type
S Type
S Type
Refrigerant type
R410A
Throttle
Type
EXV
Design pressure
MPa
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
piping
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
OD 16.5
mm
Controller
42VH020H113000101
Power supply
Input
Rated current
Capacity
Heating
42VH028H113000100
42VH030H113000100
5.6
7.1
8
19100
24200
27300
30700
W
51
79
95
95
A
0.2
0.33
0.39
0.39
kW
6.3
8
9
10
Btu/h
21500
27300
30700
34100
W
51
79
95
95
Rated current
A
0.2
0.33
0.39
0.39
m3/h
925/860/755
1190/780/580
1320/840/640
1320/840/640
Indoor noise level (H/M/L)
544/506/444
700/459/341
776/494/376
776/494/376
dB(A)
40/38/34
45/42/41
48/43/38
49/43/38
Dimension (W×H×D)
mm
1072×230×315
1250×245×325
1250×245×325
1250×245×325
Packing (W×H×D)
mm
1180×315×415
1345×335×430
1345×335×430
1345×335×430
Net/Gross weight
kg
15.1/19.5
19.9/25
19.9/25
19.9/25
Type
S Type
R Type
R Type
R Type
Panel
Refrigerant type
Design pressure
Refrigerant
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
piping
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe diameter
Controller
mm
OD 16.5
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m)(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)
3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.
* Specifications are subject to change without prior notice for product improvement.
61
4.5
15400
W
31
31
31
44
0.2
A
0.14
0.14
0.14
kW
2.4
3.1
4
5
BTU
8200
10900
13600
17100
31
31
31
44
0.14
0.14
0.14
0.2
m3/h
525/480/430
525/480/430
590/520/480
860/755/630
CFM
309/282/253
309/282/253
347/306/283
506/444/371
dB(A)
35/32/29
35/32/29
35/32/29
40/38/34
Dimension (W×H×D)
mm
915×290×230
915×290×230
915×290×230
1072×315×230
Packing (W×H×D)
mm
1020×390×315
1020×390×315
1020×390×315
1180×415×315
Net/Gross weight
kg
13/16.5
13/16.5
13/16.5
15.1/18.8
Type
S Type
S Type
S Type
S Type
Panel
R410A
Throttle
Type
EXV
Design pressure
MPa
4.4/2.6
Refrigerant piping
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
ODФ16.5
mm
Wireless controller
Model
42VH020H112000101
Capacity
Cooling
kW
5.6
7.1
8
9
BTU
19100
24200
27300
30700
W
44
75
86
86
A
0.2
0.33
0.39
0.39
kW
6
8
9
10
BTU
21500
27300
30700
34100
Input
W
44
75
86
86
Rated current
A
0.2
0.33
0.39
0.39
m3/h
925/860/755
1190/780/580
1320/840/640
1320/840/640
CFM
544/506/444
700/459/341
776/494/376
776/494/376
dB(A)
40/38/34
47/43/42
48/43/38
49/43/38
Indoor noise level (sound pressure)
Dimension (W×H×D)
mm
1072×315×230
1250×245×325
1250×245×325
1250×245×325
Packing (W×H×D)
mm
1180×415×315
1345×335×430
1345×335×430
1345×335×430
Net/Gross weight
kg
15.1/18.8
19.9/25
19.9/25
19.9/25
Type
S Type
R Type
R Type
R Type
Panel
Refrigerant piping
R410A
Type
EXV
MPa
4.4/2.6
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe dia.
Controller
42VH030H112000102
Rated current
Indoor air flow (H/M/L)
Indoor unit
42VH028H112000102
220-240V, 1Ph, 50Hz
Input
Capacity
Heating
42VH024H112000102
V- Ph-Hz
Design pressure
4.4/2.6
MPa
3.6
12300
A
Throttle
EXV
Type
2.8
9600
Refrigerant type
R410A
Throttle
2.2
7500
W
Indoor noise level (sound pressure)
9
Btu/h
CFM
kW
BTU
Rated current
Indoor air flow (H/M/L)
Indoor unit
42VH016H112000101
Input
Power supply
Input
Indoor air flow (H/M/L)
Indoor unit
kW
Heating
42VH012H112000101
220-240V, 1Ph, 50Hz
Controller
208-230V-1Ph~60Hz
V- Ph-Hz
Capacity
Cooling
42VH024H113000100
Capacity
Drainage water pipe dia.
Wireless remote controller
Model
Capacity
Cooling
42VH009H112000101
Refrigerant type
Refrigerant
Drainage water pipe diameter
42VH007H112000101
V- Ph-Hz
kW
Dimension (W×H×D)
Panel
Model
Power supply
208-230V-1Ph~60Hz
V- Ph-Hz
Capacity
Cooling
42VH009H113000101
mm
ODФ16.5
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m)(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)
3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.
* Specifications are subject to change without prior notice for product improvement.
62
Specifications 50Hz
Specifications 60Hz
Model
42VH007H113000101
Power supply
Input
Rated current
Capacity
Heating
Input
Rated current
Indoor air flow (H/M/L)
Indoor noise level (H/M/L)
Indoor unit
42VH012H113000101
42VH016H113000101
2.2
2.8
3.6
4.5
Btu/h
7500
9600
12300
15400
W
25
28
30
51
Input
A
0.14
0.14
0.14
0.2
Rated current
kW
2.4
3.2
4
5
Btu/h
8200
10900
13600
17100
W
25
28
30
51
A
0.14
0.14
0.14
0.2
m3/h
525/480/430
525/480/430
590/520/480
860/755/630
CFM
309/282.5/253
309/282.5/253
347/306/282.5
506/444/370.8
dB(A)
35/32/29
35/32/29
35/32/29
40/38/34
mm
915×230×290
915×230×290
915×230×290
1072×230×315
Packing (W×H×D)
mm
1020×315×390
1020×315×390
1020×315×390
1180×315×415
Net/Gross weight
kg
13/16.8
13/16.8
13/16.8
15.1/19.5
Type
S Type
S Type
S Type
S Type
Refrigerant type
R410A
Throttle
Type
EXV
Design pressure
MPa
4.4/2.6
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
piping
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
OD 16.5
mm
Controller
42VH020H113000101
Power supply
Input
Rated current
Capacity
Heating
42VH028H113000100
42VH030H113000100
5.6
7.1
8
19100
24200
27300
30700
W
51
79
95
95
A
0.2
0.33
0.39
0.39
kW
6.3
8
9
10
Btu/h
21500
27300
30700
34100
W
51
79
95
95
Rated current
A
0.2
0.33
0.39
0.39
m3/h
925/860/755
1190/780/580
1320/840/640
1320/840/640
Indoor noise level (H/M/L)
544/506/444
700/459/341
776/494/376
776/494/376
dB(A)
40/38/34
45/42/41
48/43/38
49/43/38
Dimension (W×H×D)
mm
1072×230×315
1250×245×325
1250×245×325
1250×245×325
Packing (W×H×D)
mm
1180×315×415
1345×335×430
1345×335×430
1345×335×430
Net/Gross weight
kg
15.1/19.5
19.9/25
19.9/25
19.9/25
Type
S Type
R Type
R Type
R Type
Panel
Refrigerant type
Design pressure
Refrigerant
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
piping
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe diameter
Controller
mm
OD 16.5
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m)(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)
3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.
* Specifications are subject to change without prior notice for product improvement.
61
4.5
15400
W
31
31
31
44
0.2
A
0.14
0.14
0.14
kW
2.4
3.1
4
5
BTU
8200
10900
13600
17100
31
31
31
44
0.14
0.14
0.14
0.2
m3/h
525/480/430
525/480/430
590/520/480
860/755/630
CFM
309/282/253
309/282/253
347/306/283
506/444/371
dB(A)
35/32/29
35/32/29
35/32/29
40/38/34
Dimension (W×H×D)
mm
915×290×230
915×290×230
915×290×230
1072×315×230
Packing (W×H×D)
mm
1020×390×315
1020×390×315
1020×390×315
1180×415×315
Net/Gross weight
kg
13/16.5
13/16.5
13/16.5
15.1/18.8
Type
S Type
S Type
S Type
S Type
Panel
R410A
Throttle
Type
EXV
Design pressure
MPa
4.4/2.6
Refrigerant piping
Liquid side
mm
Ф6.35
Ф6.35
Ф6.35
Ф6.35
Gas side
mm
Ф12.7
Ф12.7
Ф12.7
Ф12.7
ODФ16.5
mm
Wireless controller
Model
42VH020H112000101
Capacity
Cooling
kW
5.6
7.1
8
9
BTU
19100
24200
27300
30700
W
44
75
86
86
A
0.2
0.33
0.39
0.39
kW
6
8
9
10
BTU
21500
27300
30700
34100
Input
W
44
75
86
86
Rated current
A
0.2
0.33
0.39
0.39
m3/h
925/860/755
1190/780/580
1320/840/640
1320/840/640
CFM
544/506/444
700/459/341
776/494/376
776/494/376
dB(A)
40/38/34
47/43/42
48/43/38
49/43/38
Indoor noise level (sound pressure)
Dimension (W×H×D)
mm
1072×315×230
1250×245×325
1250×245×325
1250×245×325
Packing (W×H×D)
mm
1180×415×315
1345×335×430
1345×335×430
1345×335×430
Net/Gross weight
kg
15.1/18.8
19.9/25
19.9/25
19.9/25
Type
S Type
R Type
R Type
R Type
Panel
Refrigerant piping
R410A
Type
EXV
MPa
4.4/2.6
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage water pipe dia.
Controller
42VH030H112000102
Rated current
Indoor air flow (H/M/L)
Indoor unit
42VH028H112000102
220-240V, 1Ph, 50Hz
Input
Capacity
Heating
42VH024H112000102
V- Ph-Hz
Design pressure
4.4/2.6
MPa
3.6
12300
A
Throttle
EXV
Type
2.8
9600
Refrigerant type
R410A
Throttle
2.2
7500
W
Indoor noise level (sound pressure)
9
Btu/h
CFM
kW
BTU
Rated current
Indoor air flow (H/M/L)
Indoor unit
42VH016H112000101
Input
Power supply
Input
Indoor air flow (H/M/L)
Indoor unit
kW
Heating
42VH012H112000101
220-240V, 1Ph, 50Hz
Controller
208-230V-1Ph~60Hz
V- Ph-Hz
Capacity
Cooling
42VH024H113000100
Capacity
Drainage water pipe dia.
Wireless remote controller
Model
Capacity
Cooling
42VH009H112000101
Refrigerant type
Refrigerant
Drainage water pipe diameter
42VH007H112000101
V- Ph-Hz
kW
Dimension (W×H×D)
Panel
Model
Power supply
208-230V-1Ph~60Hz
V- Ph-Hz
Capacity
Cooling
42VH009H113000101
mm
ODФ16.5
Wireless controller
Notes:
1. Nominal cooling capacities are based on the following conditions: return air temperature : 80.6°F(27°C)DB,66.2°F(19°C)WB,and outdoor temperature:
95°F(35°C)DB,equivalent ref. piping: 26.25ft(8m)(horizontal)
2. Nominal heating capacities are based on the following conditions: return air temperature: 68°F(20°C)DB, outdoor temperature:
44.6°F(7°C)DB,42.8°F(6°C)WB, and equivalent ref. Piping: 26.25ft(8m)(horizontal)
3. Sound level is measured 3.28ft.(1m) below the air out-let both in horizontal and vertical distance.
* Specifications are subject to change without prior notice for product improvement.
62
Specifications 60Hz
Fresh Air Processing Unit
42VD042H113211010 42VD048H113211010 42VD070H113211010 42VD085H113211010 42VD096H113211010
Sale Model
Power supply
208-230V-1Ph~60Hz
V-Ph-Hz
kW
12.5
14
20
25
28
Btu
42600
47800
68200
85300
95500
Power Input
W
468
468
616
616
616
Rated Current
A
2.4
2.4
4.2
4.2
4.2
kW
10.5
12
18
20
22
BTU
36000
41000
61400
68200
75000
Power Input
W
468
468
616
616
616
Rated Current
A
2.4
2.4
4.2
4.2
4.2
Capacity
Cooling
Capacity
Heating
Healthy and comfortable
Fresh air is imported, provides a healthy and comfortable living environment.
100% Fresh air processing unit
the longest distance
of air supply is 14m
Both fresh air filtration and heating/cooling can be
achieved in a single system.
Indoor units and fresh air processing unit can be connected to the same refrigerant system, increasing
design flexibility and greatly reducing total system costs.
Fresh air in take
INDOOR UNIT
Air supply
The height of air
supply is 6.5m
m3/h
2142/1870/1611
2142/1870/1611
3210/2700/2200
3205/2750/2300
3205/2750/2300
CFM
1261/1101/948
1261/1101/948
1889/1589/1295
1886/1619/1354
1886/1619/1354
Pa
50(50~196)
50(50~196)
200(50~280)
200(50~280)
200(50~280)
dB(A)
54/52/50
54/52/50
54/53/51
55/54/52
55/54/52
Indoor air flow (H/M/L)
Air return
Indoor external static pressure (H)
Indoor noise level
(Sound pressure)(H/M/L)
Indoor unit
High external static pressure
Dimension (W×H×D)
mm
1300×420×690
1443×470×810
Packing (W×H×D)
mm
1436×450×768
1509×550×990
Net/Gross weight
Kg
Refrigerant type
69.5/76
69.5/76
114/124
114/124
114/124
R410A
R410A
R410A
R410A
R410A
External static pressure can be up to 196Pa(125~140 models) and 280Pa(200~280 models) for more flexible
duct applications. The maximal distance of air supply is about 45.9ft.(14m) and the maximum height of air supply
is about 21.3ft.(6.5m).
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.2/2.0
4.2/2.0
4.2/2.0
Innovative air supply technology for excellent room temperature control
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage pipe diameter
mm
OD Ф32
OD Ф32
OD Ф32
OD Ф32
OD Ф32
Layout Example:
Throttle type
Refrigerant
piping
Outdoor Units
Controller
Indoor Unit
Indoor Unit
Outdoor Air processing unit
Air-conditioning
63
Fresh air supply
EXV
EXV
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: outdoor air temperature:91.4°F(33°C)DB,75.2°F(24°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
2. Nominal heating capacities are based on the following conditions: outdoor air temperature:32°F(0°C)DB,30.2°F(-1°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
3. Sound level is measured 4.59ft.(1.4m) from the air out-let.
* External static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
Connection Conditions:
The following restrictions must be observed in order to maintain the indoor units connected to the same system.
* When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units.
* When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units.
* Outdoor-air processing units can be used without indoor units.
64
Specifications 60Hz
Fresh Air Processing Unit
42VD042H113211010 42VD048H113211010 42VD070H113211010 42VD085H113211010 42VD096H113211010
Sale Model
Power supply
208-230V-1Ph~60Hz
V-Ph-Hz
kW
12.5
14
20
25
28
Btu
42600
47800
68200
85300
95500
Power Input
W
468
468
616
616
616
Rated Current
A
2.4
2.4
4.2
4.2
4.2
kW
10.5
12
18
20
22
BTU
36000
41000
61400
68200
75000
Power Input
W
468
468
616
616
616
Rated Current
A
2.4
2.4
4.2
4.2
4.2
Capacity
Cooling
Capacity
Heating
Healthy and comfortable
Fresh air is imported, provides a healthy and comfortable living environment.
100% Fresh air processing unit
the longest distance
of air supply is 14m
Both fresh air filtration and heating/cooling can be
achieved in a single system.
Indoor units and fresh air processing unit can be connected to the same refrigerant system, increasing
design flexibility and greatly reducing total system costs.
Fresh air in take
INDOOR UNIT
Air supply
The height of air
supply is 6.5m
m3/h
2142/1870/1611
2142/1870/1611
3210/2700/2200
3205/2750/2300
3205/2750/2300
CFM
1261/1101/948
1261/1101/948
1889/1589/1295
1886/1619/1354
1886/1619/1354
Pa
50(50~196)
50(50~196)
200(50~280)
200(50~280)
200(50~280)
dB(A)
54/52/50
54/52/50
54/53/51
55/54/52
55/54/52
Indoor air flow (H/M/L)
Air return
Indoor external static pressure (H)
Indoor noise level
(Sound pressure)(H/M/L)
Indoor unit
High external static pressure
Dimension (W×H×D)
mm
1300×420×690
1443×470×810
Packing (W×H×D)
mm
1436×450×768
1509×550×990
Net/Gross weight
Kg
Refrigerant type
69.5/76
69.5/76
114/124
114/124
114/124
R410A
R410A
R410A
R410A
R410A
External static pressure can be up to 196Pa(125~140 models) and 280Pa(200~280 models) for more flexible
duct applications. The maximal distance of air supply is about 45.9ft.(14m) and the maximum height of air supply
is about 21.3ft.(6.5m).
Design pressure(H/L)
MPa
4.4/2.6
4.4/2.6
4.2/2.0
4.2/2.0
4.2/2.0
Innovative air supply technology for excellent room temperature control
Liquid side
mm
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Ф9.53
Gas side
mm
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Drainage pipe diameter
mm
OD Ф32
OD Ф32
OD Ф32
OD Ф32
OD Ф32
Layout Example:
Throttle type
Refrigerant
piping
Outdoor Units
Controller
Indoor Unit
Indoor Unit
Outdoor Air processing unit
Air-conditioning
63
Fresh air supply
EXV
EXV
Wireless remote controller
Notes:
1. Nominal cooling capacities are based on the following conditions: outdoor air temperature:91.4°F(33°C)DB,75.2°F(24°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
2. Nominal heating capacities are based on the following conditions: outdoor air temperature:32°F(0°C)DB,30.2°F(-1°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
3. Sound level is measured 4.59ft.(1.4m) from the air out-let.
* External static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
Connection Conditions:
The following restrictions must be observed in order to maintain the indoor units connected to the same system.
* When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units.
* When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units.
* Outdoor-air processing units can be used without indoor units.
64
Specifications 50Hz
42VD042H112211010 42VD048H112211010 42VD070H112211010 42VD085H112211010 42VD096H112211010
Sale Model
V-Ph-Hz
Power supply
Capacity
12.5
14
20
25
28
42600
47800
68200
85300
95500
568
568
1300
1350
1350
2.55
2.55
5.80
6.00
6.00
10.5
16
18
20
22
36000
41000
61400
68200
75000
568
568
1300
1350
1350
A
2.55
2.55
5.80
6.00
6.00
A
2.4
2.4
5.3
5.6
5.6
2142/1870/1611
2142/1870/1611
2870/2620/2150
3005/2700/2250
3005/2700/2250
1261/1101/948
1261/1101/948
1689/1542/1265
1766/1589/1324
1766/1589/1324
30~220
30~220
50~260
50~260
50~260
54/52/50
54/52/50
54/53/51
55/54/52
55/54/52
kW
BTU
Cooling
Power input
Rated current
Capacity
220-240V-1Ph-50Hz
W
A
kW
BTU
Heating
Power input
Rated current
Max. current
W
m /h
3
Indoor air flow (Hi/Mid/Lo)
CFM
Indoor external static pressure (Hi)
Noise level (Sound pressure)(Hi/Mid/Lo)
Indoor unit
Pa
dB(A)
Dimension (W*H*D)
mm
1368*420*691
1368*420*691
1443*470*810
1443*470*810
1443*470*810
Packing (W*H*D)
mm
1436*450*768
1436*450*768
1509*550*990
1509*550*990
1509*550*990
Net/Gross weight
Kg
69.5/76
69.5/76
115/125
115/125
115/125
R410A
R410A
R410A
R410A
R410A
Refrigerant type
Throttle type
EXV
Design pressure
Refrigerant
piping
Control Systems
MPa
Liquid side
Gas side
Drainage pipe diameter
mm
mm2
Controller
4.2/2.0
4.2/2.0
4.2/2.0
4.2/2.0
4.2/2.0
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
OD Ф25
OD Ф25
OD Ф32
OD Ф32
OD Ф32
Wireless Controller
Operation temp (outdoor)
℃
COOLING +20~+43; HEATING -5 ~20
Notes:
1. Nominal cooling capacities are based on the following conditions: outdoor air temperature:91.4°F(33°C)DB,75.2°F(24°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
2. Nominal heating capacities are based on the following conditions: outdoor air temperature:32°F(0°C)DB,30.2°F(-1°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
3. Sound level is measured 4.59ft.(1.4m) from the air out-let.
* External static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
Connection Conditions:
The following restrictions must be observed in order to maintain the indoor units connected to the same system.
* When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units.
* When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units.
* Outdoor-air processing units can be used without indoor units.
65
66
Specifications 50Hz
42VD042H112211010 42VD048H112211010 42VD070H112211010 42VD085H112211010 42VD096H112211010
Sale Model
V-Ph-Hz
Power supply
Capacity
12.5
14
20
25
28
42600
47800
68200
85300
95500
568
568
1300
1350
1350
2.55
2.55
5.80
6.00
6.00
10.5
16
18
20
22
36000
41000
61400
68200
75000
568
568
1300
1350
1350
A
2.55
2.55
5.80
6.00
6.00
A
2.4
2.4
5.3
5.6
5.6
2142/1870/1611
2142/1870/1611
2870/2620/2150
3005/2700/2250
3005/2700/2250
1261/1101/948
1261/1101/948
1689/1542/1265
1766/1589/1324
1766/1589/1324
30~220
30~220
50~260
50~260
50~260
54/52/50
54/52/50
54/53/51
55/54/52
55/54/52
kW
BTU
Cooling
Power input
Rated current
Capacity
220-240V-1Ph-50Hz
W
A
kW
BTU
Heating
Power input
Rated current
Max. current
W
m /h
3
Indoor air flow (Hi/Mid/Lo)
CFM
Indoor external static pressure (Hi)
Noise level (Sound pressure)(Hi/Mid/Lo)
Indoor unit
Pa
dB(A)
Dimension (W*H*D)
mm
1368*420*691
1368*420*691
1443*470*810
1443*470*810
1443*470*810
Packing (W*H*D)
mm
1436*450*768
1436*450*768
1509*550*990
1509*550*990
1509*550*990
Net/Gross weight
Kg
69.5/76
69.5/76
115/125
115/125
115/125
R410A
R410A
R410A
R410A
R410A
Refrigerant type
Throttle type
EXV
Design pressure
Refrigerant
piping
Control Systems
MPa
Liquid side
Gas side
Drainage pipe diameter
mm
mm2
Controller
4.2/2.0
4.2/2.0
4.2/2.0
4.2/2.0
4.2/2.0
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф15.9
Ф15.9
Ф15.9
Ф15.9
Ф15.9
OD Ф25
OD Ф25
OD Ф32
OD Ф32
OD Ф32
Wireless Controller
Operation temp (outdoor)
℃
COOLING +20~+43; HEATING -5 ~20
Notes:
1. Nominal cooling capacities are based on the following conditions: outdoor air temperature:91.4°F(33°C)DB,75.2°F(24°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
2. Nominal heating capacities are based on the following conditions: outdoor air temperature:32°F(0°C)DB,30.2°F(-1°C)WB, equivalent ref. piping:26.25ft. (8m)(horizontal).
3. Sound level is measured 4.59ft.(1.4m) from the air out-let.
* External static pressure are based on high speed indoor airflow.
* Specifications are subject to change without prior notice for product improvement.
Connection Conditions:
The following restrictions must be observed in order to maintain the indoor units connected to the same system.
* When outdoor-air processing units are connected, the total connection capacity must be within 50% to 100% of that of the outdoor units.
* When outdoor-air processing units and standard indoor units are connected, the total connection capacity of the outdoor-air processing units must not exceed 30% of that of the outdoor units.
* Outdoor-air processing units can be used without indoor units.
65
66
Control Systems
Network Control
CIF-15-CM
Centralized Control
Individual control
Indoor Centralized Controller
(Touch key)
X,Y,E
Remote controller
CRF-30-CM
iPad
WL-12-CM
WL-14-CM
Laptop
Connectable to
multiple Gateway types
IMM Software
Accessories
Indoor Centralized
Controller
M-INTERFACE Gateway
Wired controller
WR-12-CM
WR-29B-CM
WR-120B-CM
WR-90D-CM
Card-key Interface CA-NIM05
X,Y,E
CRF-10-CM
Lonworks BMS
CA-NIM05
NW-LNW-CM
Wired controller
Card-key
Infrared Sensor CA-NIM09
BACnet BMS
NW-BCN-CM
Web monitoring system
Outdoor Centralized
Monitor
F1,F2,E
Infrared control box
K1,K2,E
Wired controller
CRC-10-CM
Modbus BMS
67
CRF-18-CM/CRF-18U-CM
Note: The wires in the diagram show the signal flows only,
while not represent the actual connecting ways.
Infrared sensor module
Outdoor units
68
Control Systems
Network Control
CIF-15-CM
Centralized Control
Individual control
Indoor Centralized Controller
(Touch key)
X,Y,E
Remote controller
CRF-30-CM
iPad
WL-12-CM
WL-14-CM
Laptop
Connectable to
multiple Gateway types
IMM Software
Accessories
Indoor Centralized
Controller
M-INTERFACE Gateway
Wired controller
WR-12-CM
WR-29B-CM
WR-120B-CM
WR-90D-CM
Card-key Interface CA-NIM05
X,Y,E
CRF-10-CM
Lonworks BMS
CA-NIM05
NW-LNW-CM
Wired controller
Card-key
Infrared Sensor CA-NIM09
BACnet BMS
NW-BCN-CM
Web monitoring system
Outdoor Centralized
Monitor
F1,F2,E
Infrared control box
K1,K2,E
Wired controller
CRC-10-CM
Modbus BMS
67
CRF-18-CM/CRF-18U-CM
Note: The wires in the diagram show the signal flows only,
while not represent the actual connecting ways.
Infrared sensor module
Outdoor units
68
Comparison of Controllers
Item
Remote controller
Model name
WL-12-CM
WL-14-CM
MAX. controllable IDU
A/C control
function
Timer
Control
Wired Controller
WR-12-CM
1
WR-120B-CM
1
Centralized Controller
WR-29B-CM
WR-90D-CM
CRF-30-CM
CRF-10-CM
WCRF-10-CM
1
64
64
WL-14-CM
WL-12-CM
On/Off
●
●
●
●
●
●
Operation mode setting
●
●
●
●
●
●
Fan speed setting
●
●
●
●
●
●
Room temp. setting
●
●
●
●
●
●
Vertical swing
●
-
-
-
-
-
Horizontal swing
●
●
●
●
●
●
Air direction
●/-
-
-
-
-
-
Economic mode
●
●
●
-
-
-
Central setting
-
-
-
-
●
●
Temp
1
Keyboard lock
●
●
●
●
●
●
Transmitting display
2
Running mode
4
Mode lock
-
-
-
-
●
●
Remote signal receiving
-
-
-
●
-
-
Functions
Portable device
Simplified user interface
The wireless remote controller is a portable control
Users can synchronize the air conditioners’ param-
device that enables users to control the A/C any-
eters with the display panel on the wireless remote
where within a distance of 11m.
controller to precisely control a room's environment.
-/●
-
-
-
-
-
Silent mode
-
-
●
●
-
-
Backlight
●
●
●
●
●
●
Current time
●/-
-
●
-
-
●
The background light allows users to operate the
RC prohibition
-
-
-
-
●
●
device in a dark room. The device lights up when a
Address
-
-
-
-
●
●
button is pressed, and turns off when a given opera-
Error code
-
-
●
-
●
●
tion is completed.
Room temp.
-
-
-
-
●
●
Period
-
-
-
-
-
Week
On/Off per day
-
-
-
-
-
4
On/Off per week
-
-
-
-
-
28
The built-in daily timer offers the convenience of auto-
On/Off timer
●
●
●
●
●
●
matically starting and stopping the system at set
FOLLOW ME
-/●
●
-
●
-
-
times.
Emergent stop
-
-
-
-
●
-
Emergent start
-
-
-
-
●
-
Besides the machine's auto addressing function,
Address setting
●
-
-
●
-
-
users can set the indoor unit's address on the wireless
BMS access
-
-
-
-
●
-
Control via internet
-
-
-
-
●
-
Air filter cleaning reminding
-
-
●
●
●/-
-
26℃ shortcut setting
Display
Wireless Remote Controller
: Available controller functions
: Not available controller functions
ON
Economic operation
8
ON/OFF
5
Time
6
Lock
7
Time ON/OFF
9
Fan speed
Background light
AUTO
Built-in timer
Auto mode
DRY mode
Timer
Lock
HEAT mode COOL mode
Eco mode Address setting
FAN mode
Follow Me
*The follow me function is available for WL-14-CM
Setting addresses
24°C
ON
0
3
6
9
12
15
OFF
18
21 Time
The indoor unit is set to work in automode from 8:00 to 20:00
remote controller WL-12-CM/WL-14-CM.
Specifications
Specifications
Model
Dimensions (H×W×D)(mm)
Power (V)
69
OFF
3
WL-14-CM
WL-12-CM
150×60×15
150×65×20
1.5V(LR03/AAA)×2
70
Comparison of Controllers
Item
Remote controller
Model name
WL-12-CM
WL-14-CM
MAX. controllable IDU
A/C control
function
Timer
Control
Wired Controller
WR-12-CM
1
WR-120B-CM
1
Centralized Controller
WR-29B-CM
WR-90D-CM
CRF-30-CM
CRF-10-CM
WCRF-10-CM
1
64
64
WL-14-CM
WL-12-CM
On/Off
●
●
●
●
●
●
Operation mode setting
●
●
●
●
●
●
Fan speed setting
●
●
●
●
●
●
Room temp. setting
●
●
●
●
●
●
Vertical swing
●
-
-
-
-
-
Horizontal swing
●
●
●
●
●
●
Air direction
●/-
-
-
-
-
-
Economic mode
●
●
●
-
-
-
Central setting
-
-
-
-
●
●
Temp
1
Keyboard lock
●
●
●
●
●
●
Transmitting display
2
Running mode
4
Mode lock
-
-
-
-
●
●
Remote signal receiving
-
-
-
●
-
-
Functions
Portable device
Simplified user interface
The wireless remote controller is a portable control
Users can synchronize the air conditioners’ param-
device that enables users to control the A/C any-
eters with the display panel on the wireless remote
where within a distance of 11m.
controller to precisely control a room's environment.
-/●
-
-
-
-
-
Silent mode
-
-
●
●
-
-
Backlight
●
●
●
●
●
●
Current time
●/-
-
●
-
-
●
The background light allows users to operate the
RC prohibition
-
-
-
-
●
●
device in a dark room. The device lights up when a
Address
-
-
-
-
●
●
button is pressed, and turns off when a given opera-
Error code
-
-
●
-
●
●
tion is completed.
Room temp.
-
-
-
-
●
●
Period
-
-
-
-
-
Week
On/Off per day
-
-
-
-
-
4
On/Off per week
-
-
-
-
-
28
The built-in daily timer offers the convenience of auto-
On/Off timer
●
●
●
●
●
●
matically starting and stopping the system at set
FOLLOW ME
-/●
●
-
●
-
-
times.
Emergent stop
-
-
-
-
●
-
Emergent start
-
-
-
-
●
-
Besides the machine's auto addressing function,
Address setting
●
-
-
●
-
-
users can set the indoor unit's address on the wireless
BMS access
-
-
-
-
●
-
Control via internet
-
-
-
-
●
-
Air filter cleaning reminding
-
-
●
●
●/-
-
26℃ shortcut setting
Display
Wireless Remote Controller
: Available controller functions
: Not available controller functions
ON
Economic operation
8
ON/OFF
5
Time
6
Lock
7
Time ON/OFF
9
Fan speed
Background light
AUTO
Built-in timer
Auto mode
DRY mode
Timer
Lock
HEAT mode COOL mode
Eco mode Address setting
FAN mode
Follow Me
*The follow me function is available for WL-14-CM
Setting addresses
24°C
ON
0
3
6
9
12
15
OFF
18
21 Time
The indoor unit is set to work in automode from 8:00 to 20:00
remote controller WL-12-CM/WL-14-CM.
Specifications
Specifications
Model
Dimensions (H×W×D)(mm)
Power (V)
69
OFF
3
WL-14-CM
WL-12-CM
150×60×15
150×65×20
1.5V(LR03/AAA)×2
70
Wired Controller
Wired Controller
AUTO
AUTO
Auto mode
DRY mode
HEAT mode
COOL mode
FAN mode
Timer
Lock
Filter cleaning
reminder
Follow Me
Address setting
Silent mode
WR-90D-CM
WR-29B-CM
Auto mode
DRY mode
HEAT mode
COOL mode
FAN mode
Timer
Lock
Reminder
Follow Me
Address setting
WR-12-CM
Functions
Functions
Follow me
Air filter cleaning reminding
Silent mode
The wired controller records the total running time of
Under the cooling, heating and auto mode,when oper-
the indoor unit. When the accumulated running time
ate the silent mode, it can reduce the running noise
reaches the pre-set value, it will remind users need to
through setting the fan speed to low. This will help you
clean the air filter of the indoor unit.
bring a quieter environment.
With the FOLLOW ME function, the wired controller
Sensor part
can detect the air temperature at the user’ s altitude
instead that of the ceiling or floor. This helps making
the room environment comfortable and the tempera-
FOLLOW ME Button
Clean the filter regularly can keep indoor air fresh and
clean, good for your health.
ture accurate.
*The follow me function is available for WR-12-CM/WR-29B-CM
model.
Setting addresses
With the address setting function,and easy for the
installation and future service. The service person
can set the address for indoor unit by, WR-29B-CM
and WR-90D-CM.
Wired controller
*Available for WR-29B-CM / WR-90D-CM model.
Built-in timer
Built-in daily timer offers the convenience of automati-
Remote signal
receiver
Air filter cleaning
reminder icon
cally starting and stopping the system at set times.
Remote signal receiving function
controller, then sent to the indoor unit and it conveniences to control.
Locking wired controller
WR-29B-CM
(Touch key)
Silent Key
The locking function can be used to prevent other people from using the
Power (V)
71
6
9
12
15
18
21 Time
Easy connection
Display panel
Wired controller
indoor unit's display panel via connecting wire.
Indoor main board
controller.
Specifications
WR-29B-CM
Dimensions (H×W×D)(mm)
3
The wired controller conveniently connects to the
Specifications
Model
0
OFF
The indoor unit is set to work in automode from 8:00 to 20:00
WR-29B-CM and WR-90D-CM provide a signal receiver for remote
controller. Signal from remote controller can be received by a wired
24°C
ON
120×120×20
DC 5V
WR-90D-CM
Model
86×86×16.5
Dimensions (H×W×D)(mm)
Power (V)
WR-12-CM
120×120×15
DC 5V
72
Wired Controller
Wired Controller
AUTO
AUTO
Auto mode
DRY mode
HEAT mode
COOL mode
FAN mode
Timer
Lock
Filter cleaning
reminder
Follow Me
Address setting
Silent mode
WR-90D-CM
WR-29B-CM
Auto mode
DRY mode
HEAT mode
COOL mode
FAN mode
Timer
Lock
Reminder
Follow Me
Address setting
WR-12-CM
Functions
Functions
Follow me
Air filter cleaning reminding
Silent mode
The wired controller records the total running time of
Under the cooling, heating and auto mode,when oper-
the indoor unit. When the accumulated running time
ate the silent mode, it can reduce the running noise
reaches the pre-set value, it will remind users need to
through setting the fan speed to low. This will help you
clean the air filter of the indoor unit.
bring a quieter environment.
With the FOLLOW ME function, the wired controller
Sensor part
can detect the air temperature at the user’ s altitude
instead that of the ceiling or floor. This helps making
the room environment comfortable and the tempera-
FOLLOW ME Button
Clean the filter regularly can keep indoor air fresh and
clean, good for your health.
ture accurate.
*The follow me function is available for WR-12-CM/WR-29B-CM
model.
Setting addresses
With the address setting function,and easy for the
installation and future service. The service person
can set the address for indoor unit by, WR-29B-CM
and WR-90D-CM.
Wired controller
*Available for WR-29B-CM / WR-90D-CM model.
Built-in timer
Built-in daily timer offers the convenience of automati-
Remote signal
receiver
Air filter cleaning
reminder icon
cally starting and stopping the system at set times.
Remote signal receiving function
controller, then sent to the indoor unit and it conveniences to control.
Locking wired controller
WR-29B-CM
(Touch key)
Silent Key
The locking function can be used to prevent other people from using the
Power (V)
71
6
9
12
15
18
21 Time
Easy connection
Display panel
Wired controller
indoor unit's display panel via connecting wire.
Indoor main board
controller.
Specifications
WR-29B-CM
Dimensions (H×W×D)(mm)
3
The wired controller conveniently connects to the
Specifications
Model
0
OFF
The indoor unit is set to work in automode from 8:00 to 20:00
WR-29B-CM and WR-90D-CM provide a signal receiver for remote
controller. Signal from remote controller can be received by a wired
24°C
ON
120×120×20
DC 5V
WR-90D-CM
Model
86×86×16.5
Dimensions (H×W×D)(mm)
Power (V)
WR-12-CM
120×120×15
DC 5V
72
Centralized Controller
Functions
Indoor Centralized Controller
COOL mode
Keyboard lock
CRF-10-CM
Swing
Remote
controller lock
Filter cleaning
reminder
Timer
HEAT mode
Stylish design
Single/unified control
CRF's stylish design suits high-end environments.
The control object can be either a single unit or all
The keyboard lock function is used to prevent
units, which vastly simplifies the control process.
operational mistakes.
Operation signal feedback ensures that all units are
working in the correct mode.
Fan mode
Net
CRF-30-CM
Cooling lock
Heating lock
Net connection
OPR.UNSUCCESS
Functions
Centralized control
Three lock modes
The centralized controller is a multifunctional device that can
control up to 64 indoor units within a maximum connection
length of 1,200m.
The device connects to the master outdoor units of Carrier's
newly designed products to simplify and centralize the wiring
configuration. The two connection modes are as follows:
Centralized controller provides a superior
way to manage the indoor units. Users are
able to make their own choice from locking
the wireless controller, locking the running
mode or lock the centralized controller's
keyboard as they wish.
X,Y,E
P,Q,E
P,Q,E
P,Q,E
Easy installation
Centralized controller offers two different appearances to mostly suit the installation. The A structure must
be embedded into the wall and the B structure doesn't need. Both of them are easy to operate.
Upper side outlet
X,Y,E
X,Y,E
X,Y,E
X,Y,E
Locking
Running
Mode
Locking
Remote
Controller
Locking
Keyboard
A
Rear side outlet
B
Indoor unit working status display
Air filter cleaning reminder function
The centralized controller displays indoor units' working
status and error codes so users can easily identify faults
via checking the error codes table in the user's manual
before contacting a service engineer.
The air filter cleaning reminder function is only
available on the touch-key central controller CRF30-CM. The "FL" icon indicates that the air filter in
a given indoor unit needs cleaning
Error code or
protection code
Under side outlet
*The A,B structure is available for CRF-30-CM,
and CRF-10-CM only has B structure
Access to network monitoring
The centralized controller is able to bridge up to 64 indoor units on the network monitoring and building
management systems.
Connecting
status matrix
X,Y,E
MODE
AUTO
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
00+
16+
ROOM.TEMP
T3
Hr ON
OFF
T2A
T2B
SET.TEMP
Air filter cleaning
reminding icon
Indoor CCM
32+
FAN
Hr
(1.6)
#
ERROR
INLINE ON OFF PROTECT
Specifications
48+
OPR.UNSUCCESS
CRF-30-CM
Model
Model
Dimensions (H*W*D)(mm)
Power (V)
73
F1,F2,E
MAX.64
GROUP QUERY RUN SET
#GROUPALL
B structure leading-out mode sketch
CRF-10-CM
CRF-30-CM
179×119×74
180×122×78 and 180×122×68
198-242V(50/60Hz)
74
Centralized Controller
Functions
Indoor Centralized Controller
COOL mode
Keyboard lock
CRF-10-CM
Swing
Remote
controller lock
Filter cleaning
reminder
Timer
HEAT mode
Stylish design
Single/unified control
CRF's stylish design suits high-end environments.
The control object can be either a single unit or all
The keyboard lock function is used to prevent
units, which vastly simplifies the control process.
operational mistakes.
Operation signal feedback ensures that all units are
working in the correct mode.
Fan mode
Net
CRF-30-CM
Cooling lock
Heating lock
Net connection
OPR.UNSUCCESS
Functions
Centralized control
Three lock modes
The centralized controller is a multifunctional device that can
control up to 64 indoor units within a maximum connection
length of 1,200m.
The device connects to the master outdoor units of Carrier's
newly designed products to simplify and centralize the wiring
configuration. The two connection modes are as follows:
Centralized controller provides a superior
way to manage the indoor units. Users are
able to make their own choice from locking
the wireless controller, locking the running
mode or lock the centralized controller's
keyboard as they wish.
X,Y,E
P,Q,E
P,Q,E
P,Q,E
Easy installation
Centralized controller offers two different appearances to mostly suit the installation. The A structure must
be embedded into the wall and the B structure doesn't need. Both of them are easy to operate.
Upper side outlet
X,Y,E
X,Y,E
X,Y,E
X,Y,E
Locking
Running
Mode
Locking
Remote
Controller
Locking
Keyboard
A
Rear side outlet
B
Indoor unit working status display
Air filter cleaning reminder function
The centralized controller displays indoor units' working
status and error codes so users can easily identify faults
via checking the error codes table in the user's manual
before contacting a service engineer.
The air filter cleaning reminder function is only
available on the touch-key central controller CRF30-CM. The "FL" icon indicates that the air filter in
a given indoor unit needs cleaning
Error code or
protection code
Under side outlet
*The A,B structure is available for CRF-30-CM,
and CRF-10-CM only has B structure
Access to network monitoring
The centralized controller is able to bridge up to 64 indoor units on the network monitoring and building
management systems.
Connecting
status matrix
X,Y,E
MODE
AUTO
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
00+
16+
ROOM.TEMP
T3
Hr ON
OFF
T2A
T2B
SET.TEMP
Air filter cleaning
reminding icon
Indoor CCM
32+
FAN
Hr
(1.6)
#
ERROR
INLINE ON OFF PROTECT
Specifications
48+
OPR.UNSUCCESS
CRF-30-CM
Model
Model
Dimensions (H*W*D)(mm)
Power (V)
73
F1,F2,E
MAX.64
GROUP QUERY RUN SET
#GROUPALL
B structure leading-out mode sketch
CRF-10-CM
CRF-30-CM
179×119×74
180×122×78 and 180×122×68
198-242V(50/60Hz)
74
Centralized Controller
Centralized Controller
Weekly Schedule Centralized
Controller
Unified On/Off Controller
AUTO
Auto mode
COOL mode
HEAT mode
Fan mode
CRF-90-CM
Unified controller design with graceful appearance and explicit panel.
WCRF-10-CM
DRY mode
Swing
Keyboard lock
Heating lock
Remote controller lock
Weekly schedule
Cooling lock
Functions
Functions
Unified control
Weekly schedule
8:00
WCRF-10-CM can include up to 64 indoor units in the
weekly schedule. Users can set up to 4 periods per
day, and select the desired running mode and room
temperature. The operating object can be a single
indoor unit or all the indoor units.
16:00
23:59
Sun
28°C
22°C
Mon
26°C
22°C
17°C
23°C
Tue
26°C
22°C
17°C
23°C
Wed
26°C
22°C
17°C
23°C
Thu
26°C
22°C
26°C
Fri
26°C
22°C
26°C
Sat
28°C
off
24°C
24°C
CRF-90-CM offers on/off and heating/cooling
functionality for indoor units based on preset
temperatures to ensure easy management.
28°C
20°C
cooling
heating
Centralized control
CRF-90-CM can be used to centrally control up to 16 indoor units.
Max.16
Three lock modes
Single/unified control mode
Centralized controller WCRF-10-CM provides a
The control object can be either a single unit or all
superior way to manage the indoor units. Users are
units, which vastly simplifies the control process.
able to make their own choice from locking the
Operation signal feedback ensures that all units are
wireless controller, locking the running mode or lock
working in the correct mode.
Light indicator
The LEDs on CRF-90-CM indicate the indoor units' running status for easy fault detection. The lights switch
the WCRF-10-CM's keyboard as they wish.
off automatically to save energy once a given operation is complete. The indicators are as follows:
Locking
Running
Mode
Locking
Remote
Controller
Light
OPR.UNSUCCESS
Locking
Keyboard
Single On/Off key
Blue
Red
Flash
Cooling/Fan
Heating
IDU Error
EEPROM Error
Unified On/Off key
Easy installation
Indoor unit working status display
CRF-90-CM can be easily mounted on the built-in cabinet:
WCRF-10-CM displays indoor units' working status
Error code or
protection code
and error codes so users can easily identify faults via
before contacting a service engineer.
GROUP QUERY RUN SET
#GROUPALL
Hr ON
Specifications
Power (V)
75
AUTO
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
00+
OFF
T2A
T2B
SET.TEMP
32+
FAN
Hr
48+
OPR.UNSUCCESS
Specifications
WCRF-10-CM
Dimensions (H*W*D)(mm)
MODE
16+
ROOM.TEMP
T3
Model
#
ERROR
INLINE ON OFF PROTECT
(1.6)
checking the error codes table in the user's manual
Connecting
status matrix
179×119×74
198-242V(50/60Hz)
Model
CRF-90-CM
Dimensions (H*W*D)(mm)
90×86×8
Power (V)
DC 5V
76
Centralized Controller
Centralized Controller
Weekly Schedule Centralized
Controller
Unified On/Off Controller
AUTO
Auto mode
COOL mode
HEAT mode
Fan mode
CRF-90-CM
Unified controller design with graceful appearance and explicit panel.
WCRF-10-CM
DRY mode
Swing
Keyboard lock
Heating lock
Remote controller lock
Weekly schedule
Cooling lock
Functions
Functions
Unified control
Weekly schedule
8:00
WCRF-10-CM can include up to 64 indoor units in the
weekly schedule. Users can set up to 4 periods per
day, and select the desired running mode and room
temperature. The operating object can be a single
indoor unit or all the indoor units.
16:00
23:59
Sun
28°C
22°C
Mon
26°C
22°C
17°C
23°C
Tue
26°C
22°C
17°C
23°C
Wed
26°C
22°C
17°C
23°C
Thu
26°C
22°C
26°C
Fri
26°C
22°C
26°C
Sat
28°C
off
24°C
24°C
CRF-90-CM offers on/off and heating/cooling
functionality for indoor units based on preset
temperatures to ensure easy management.
28°C
20°C
cooling
heating
Centralized control
CRF-90-CM can be used to centrally control up to 16 indoor units.
Max.16
Three lock modes
Single/unified control mode
Centralized controller WCRF-10-CM provides a
The control object can be either a single unit or all
superior way to manage the indoor units. Users are
units, which vastly simplifies the control process.
able to make their own choice from locking the
Operation signal feedback ensures that all units are
wireless controller, locking the running mode or lock
working in the correct mode.
Light indicator
The LEDs on CRF-90-CM indicate the indoor units' running status for easy fault detection. The lights switch
the WCRF-10-CM's keyboard as they wish.
off automatically to save energy once a given operation is complete. The indicators are as follows:
Locking
Running
Mode
Locking
Remote
Controller
Light
OPR.UNSUCCESS
Locking
Keyboard
Single On/Off key
Blue
Red
Flash
Cooling/Fan
Heating
IDU Error
EEPROM Error
Unified On/Off key
Easy installation
Indoor unit working status display
CRF-90-CM can be easily mounted on the built-in cabinet:
WCRF-10-CM displays indoor units' working status
Error code or
protection code
and error codes so users can easily identify faults via
before contacting a service engineer.
GROUP QUERY RUN SET
#GROUPALL
Hr ON
Specifications
Power (V)
75
AUTO
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16
00+
OFF
T2A
T2B
SET.TEMP
32+
FAN
Hr
48+
OPR.UNSUCCESS
Specifications
WCRF-10-CM
Dimensions (H*W*D)(mm)
MODE
16+
ROOM.TEMP
T3
Model
#
ERROR
INLINE ON OFF PROTECT
(1.6)
checking the error codes table in the user's manual
Connecting
status matrix
179×119×74
198-242V(50/60Hz)
Model
CRF-90-CM
Dimensions (H*W*D)(mm)
90×86×8
Power (V)
DC 5V
76
Centralized Monitor
Central Control Software
Outdoor Centralized Monitor
CRC-10-CM
Query
parameters
4-way/EXV
valve
Protection/
Error codes
Power
consumption
Forced
Cooling
With the ODU
communication
With the PC
communication
Forced
Cooling
Functions
ODU parameters display
CRC-10-CM enables users to easily check outdoor units' running status, including frequency, temperature,
current, pressure, protection codes and error codes.
Forced
Cooling
Graph 2 LCD Screen
Access to network monitoring
IMM
Software
CRC-10-CM can connect up to 8 refrigerant systems and 32 outdoor units to the network system.
K1,K2,E
PC
Max.4
system 1
Web Access
Laptop
Max.32
K1,K2,E
SMS modem
Router
Tablet
Max.4
IMM Gateway
system 2
M-interface web gateway
K1,K2,E
Max.4
A/C Systems
system 8
Outdoor units
Specifications
Model
CRC-10-CM
Dimensions(H×W×D)(mm)
120×120×15
Power (V)
77
Power ammeter
Indoor units
198-242V(50/60Hz)
78
Centralized Monitor
Central Control Software
Outdoor Centralized Monitor
CRC-10-CM
Query
parameters
4-way/EXV
valve
Protection/
Error codes
Power
consumption
Forced
Cooling
With the ODU
communication
With the PC
communication
Forced
Cooling
Functions
ODU parameters display
CRC-10-CM enables users to easily check outdoor units' running status, including frequency, temperature,
current, pressure, protection codes and error codes.
Forced
Cooling
Graph 2 LCD Screen
Access to network monitoring
IMM
Software
CRC-10-CM can connect up to 8 refrigerant systems and 32 outdoor units to the network system.
K1,K2,E
PC
Max.4
system 1
Web Access
Laptop
Max.32
K1,K2,E
SMS modem
Router
Tablet
Max.4
IMM Gateway
system 2
M-interface web gateway
K1,K2,E
Max.4
A/C Systems
system 8
Outdoor units
Specifications
Model
CRC-10-CM
Dimensions(H×W×D)(mm)
120×120×15
Power (V)
77
Power ammeter
Indoor units
198-242V(50/60Hz)
78
Central Control Software
Various Managements
IMM(Intelligent Manager of Carrier)
Simple Operation and Management
4th Generation Network Control System
Click & Operate, a user-friendly interface allows even non-experts to perform
the building management system easily.
4GNS-10-CM 4GNS-10-IF
Data Management
Functions
Operational information of individual indoor units are monitored, allowing for
distribution of power consumption at outdoor units.
Stores operation data on multiple systems and displays it in graphical format for
visual management.
Uses IMM software to generate tenant reports and help building owners bill for
energy use.
Intelligent Manager of Carrier, designed specifically to control VRF systems, is based on a centralized format
and dedicated to the complete control and monitoring of all the system’s functions. It can be used as a flexible
multi-purpose system and applied to a variety of needs, according to the scale, purpose and control method of
each building.
Up to 4 M-interfaces, 64 refrigerant systems,
1,024 indoor units, and 256 outdoor units can be
controlled by one PC.
Web Access
Electricity charge distribution
User friendly operation
Generate operational history reports
(daily, weekly, monthly)
Fault display & Warning message
Central building monitoring and control
Energy saving management
SMS modem (optional)
Annual schedule control
Low-load operation indicate
Filter replacement reminder
Emergency stop and Alarm signal output
Network Control Application
Remote Control
Local
C an ru n o n , Win d o w 7 _ 6 4 b it a n d
Window XP_32 bit.
Can monitor and control A/C anytime,
anywhere by PC, iPhone, iPad and
notebook computer.
Support WEB access: IE, Firefox, Safari
and Chrome.
Enables remote access through DSL,
VPNs and so on.
Max.IDU:1024
79
Electricity Charge Distribution(Patented)
Provides information on proportional electrical power distribution to optimize
electricity consumption management.
Uses software to calculate electric power proportional distribution, output and save electricity consumption data for each indoor unit (or
group) which is connected to the intelligent manager.
Applies the patented Carrier Calculation Method to calculate consumption rates according to capacity demand which is based on various
parameters: setting temperature, room temperature, running mode, rated HP, public areas, unused rooms, and nighttime use; outputs
this information on a charge calculation sheet to evenly divide power consumption charges among tenants.
Hightlights
Web Access function
Visual Navigation
With the web access function, a PC, laptop computer or a smart phone can be used as a remote
controller.
Clicking the jump button will display a list of all available screens. Clicking the back button will return to
the previous screen.
Energy Saving Management
Data Backup
Based on a predetermined schedule, the Intelligent
Manager executes capacity control and intermittent
operations on all air conditioning units to maintain a
high comfort index.
The M-interface will automatically back up data on the
installed SD card (2GB) in case system failure occurs,
such as: power failure or system dam. IMM software
also stores the previous 3 months' operational data on
the HDD.
Schedule Control
Multiple Languages
Automatically performs facility start/stop control,
switches the operating mode, sets temperatures and
enables/disables the remote control according to the
present time schedule. 4 sections and 20 actions
per day for each single unit or group.
Provides seven language settings:
Warning Message
Electricity Charge Distribution
The system can receive error messages from air
conditioning units in more than one buildings or
structures via public phone lines.
*Requires the Carrier "SMS Modem" to send automatic warning messages to designated phone numbers.
English
French
Italian
Russian
German
Spanish
Simple Chinese
Electricity charges can be easily divided when billing
users for air conditioning power charges; for example,
for tenants in a commercial building, offices in a
rented building, or rooms in a hotel.
80
Central Control Software
Various Managements
IMM(Intelligent Manager of Carrier)
Simple Operation and Management
4th Generation Network Control System
Click & Operate, a user-friendly interface allows even non-experts to perform
the building management system easily.
4GNS-10-CM 4GNS-10-IF
Data Management
Functions
Operational information of individual indoor units are monitored, allowing for
distribution of power consumption at outdoor units.
Stores operation data on multiple systems and displays it in graphical format for
visual management.
Uses IMM software to generate tenant reports and help building owners bill for
energy use.
Intelligent Manager of Carrier, designed specifically to control VRF systems, is based on a centralized format
and dedicated to the complete control and monitoring of all the system’s functions. It can be used as a flexible
multi-purpose system and applied to a variety of needs, according to the scale, purpose and control method of
each building.
Up to 4 M-interfaces, 64 refrigerant systems,
1,024 indoor units, and 256 outdoor units can be
controlled by one PC.
Web Access
Electricity charge distribution
User friendly operation
Generate operational history reports
(daily, weekly, monthly)
Fault display & Warning message
Central building monitoring and control
Energy saving management
SMS modem (optional)
Annual schedule control
Low-load operation indicate
Filter replacement reminder
Emergency stop and Alarm signal output
Network Control Application
Remote Control
Local
C an ru n o n , Win d o w 7 _ 6 4 b it a n d
Window XP_32 bit.
Can monitor and control A/C anytime,
anywhere by PC, iPhone, iPad and
notebook computer.
Support WEB access: IE, Firefox, Safari
and Chrome.
Enables remote access through DSL,
VPNs and so on.
Max.IDU:1024
79
Electricity Charge Distribution(Patented)
Provides information on proportional electrical power distribution to optimize
electricity consumption management.
Uses software to calculate electric power proportional distribution, output and save electricity consumption data for each indoor unit (or
group) which is connected to the intelligent manager.
Applies the patented Carrier Calculation Method to calculate consumption rates according to capacity demand which is based on various
parameters: setting temperature, room temperature, running mode, rated HP, public areas, unused rooms, and nighttime use; outputs
this information on a charge calculation sheet to evenly divide power consumption charges among tenants.
Hightlights
Web Access function
Visual Navigation
With the web access function, a PC, laptop computer or a smart phone can be used as a remote
controller.
Clicking the jump button will display a list of all available screens. Clicking the back button will return to
the previous screen.
Energy Saving Management
Data Backup
Based on a predetermined schedule, the Intelligent
Manager executes capacity control and intermittent
operations on all air conditioning units to maintain a
high comfort index.
The M-interface will automatically back up data on the
installed SD card (2GB) in case system failure occurs,
such as: power failure or system dam. IMM software
also stores the previous 3 months' operational data on
the HDD.
Schedule Control
Multiple Languages
Automatically performs facility start/stop control,
switches the operating mode, sets temperatures and
enables/disables the remote control according to the
present time schedule. 4 sections and 20 actions
per day for each single unit or group.
Provides seven language settings:
Warning Message
Electricity Charge Distribution
The system can receive error messages from air
conditioning units in more than one buildings or
structures via public phone lines.
*Requires the Carrier "SMS Modem" to send automatic warning messages to designated phone numbers.
English
French
Italian
Russian
German
Spanish
Simple Chinese
Electricity charges can be easily divided when billing
users for air conditioning power charges; for example,
for tenants in a commercial building, offices in a
rented building, or rooms in a hotel.
80
Accessories
Weekly schedule control
Data converter
● With weekly schedule function for iPad.
● Multiple sections in each day for single unit or group.
CIF-15-CM
● Automatically performs facility start/stop control, operating mode, setting temperatures and according to the
● Can realize data conversion between TCP/IP protocol and 485 protocol.
present time schedule.
● WEB function realizes VRF system's webpage access.
● User can monitor and query the air conditioners through LAN and WAN.
● Providing the TCP / IP port for VRF system of Carrier to achieve WEB/HTTP/TCP/IP access.
● Can remotely control the A/C systems through computer, iPhone, iPad or other intelligent terminals.
Network example
● Can be directly connected with XYE port of the indoor units.
● Up to connect 64 indoor units.
● CRF-10-CM/CRF-30-CM is optional and can be connected with CIF-15-CM through F1, F2 and E ports.
● The system consisting A/C system, data converter CIF-15-CM, router, cloud server and control terminal.
Web features
● Query and control single unit or group.
● Weekly schedule setting: can set multiple sections in each day for single unit or group.
● Group user control : a user can use the same ID to manage hundreds of CIF-15-CM,
Cloud Servers
PC
CIF-15-CM
when selecting the "As group user" button on the login page.
● History error: easy service and management with history error function.
XYE
LAN
F1 F2 E
Router
CRF-30-CM
Indoor units
Optional
Iphone
Max.64
Intelligent control
● The air conditioner remote control can be accessed by mobile phone or tablet computer.
● You can query the running state of the air conditioner any time and any where and even make an
Simply control interface
● Software control/ Cloud server control (WEB access).
appointment in advance.
● Can remotely turn off the air conditioner to avoid the power waste, when you are in a hurry to leave.
● Click & operate, a user-friendly interface.
● Allows signal and group control.
● Simplified user control interface.
● Color indication and icon makes it easy to recognize unit state.
● Full screen display and the temperature can be adjusted by fingers' sliding.
81
82
Accessories
Weekly schedule control
Data converter
● With weekly schedule function for iPad.
● Multiple sections in each day for single unit or group.
CIF-15-CM
● Automatically performs facility start/stop control, operating mode, setting temperatures and according to the
● Can realize data conversion between TCP/IP protocol and 485 protocol.
present time schedule.
● WEB function realizes VRF system's webpage access.
● User can monitor and query the air conditioners through LAN and WAN.
● Providing the TCP / IP port for VRF system of Carrier to achieve WEB/HTTP/TCP/IP access.
● Can remotely control the A/C systems through computer, iPhone, iPad or other intelligent terminals.
Network example
● Can be directly connected with XYE port of the indoor units.
● Up to connect 64 indoor units.
● CRF-10-CM/CRF-30-CM is optional and can be connected with CIF-15-CM through F1, F2 and E ports.
● The system consisting A/C system, data converter CIF-15-CM, router, cloud server and control terminal.
Web features
● Query and control single unit or group.
● Weekly schedule setting: can set multiple sections in each day for single unit or group.
● Group user control : a user can use the same ID to manage hundreds of CIF-15-CM,
Cloud Servers
PC
CIF-15-CM
when selecting the "As group user" button on the login page.
● History error: easy service and management with history error function.
XYE
LAN
F1 F2 E
Router
CRF-30-CM
Indoor units
Optional
Iphone
Max.64
Intelligent control
● The air conditioner remote control can be accessed by mobile phone or tablet computer.
● You can query the running state of the air conditioner any time and any where and even make an
Simply control interface
● Software control/ Cloud server control (WEB access).
appointment in advance.
● Can remotely turn off the air conditioner to avoid the power waste, when you are in a hurry to leave.
● Click & operate, a user-friendly interface.
● Allows signal and group control.
● Simplified user control interface.
● Color indication and icon makes it easy to recognize unit state.
● Full screen display and the temperature can be adjusted by fingers' sliding.
81
82
Accessories
Accessories
BACnet® BMS Gateway
Modbus BMS Gateway
Contains 4 groups of RS485 communication ports and be able to
connect up to 256 indoor units or 128 outdoor units to the BMS.
Be free to connect to the BMS or not.
Supports Modbus protocol networks
Bridges the Carrier central A/C system and the BMS
Establishes a Modbus network comprising up to 1,024 indoor units and 64
outdoor units
Transfers data in RTU mode
Provides a wide voltage range: 12-48V DC
NW-BCN-CM
CRF-18-CM/CRF-18U-CM
Network example
Network example
Indoor Units
Modbus agreement system
XYE
NW-BCN-CM
CRF-30-CM
CRF-30-CM
Indoor units
F1 F2 E
F1,F2,E
HUB
Modbus
Gateway
PQE
XYE
K1,K2,E
Outdoor Units
CRC-10-CM
P,Q,E
Outdoor units
BACnet/IP protocol
X,Y,E
K1,K2,E
XYE
Modbus Master
TCP/IP
Max.64
P,Q,E
Max.64
CRF-30-CM
Indoor units
F1,F2
X,Y,E
K1,K2,E
A+,A-,GND
Web monitoring
system
BMS
K1 K2 E
Modbus
Gateway
CRC-10-CM
Outdoor units
PQE
K1,K2,E
Max.16
Indoor units
Max.64
P,Q,E
CRF-30-CM
Monitoring units online
F1,F2
NW-BCN-CM allows users to track units' operational status and change their running parameters on Internet
Explorer for maximum control convenience
Wide compatibility
1
BMS software
SIMENS
APOGEE
Brand
APOGEE
A N Y W
H E R E
TM
2
TRANE
CRC-10-CM
One Modbus gateway can bridge one refrigerant system with a PC or the Modbus master.
NW-BCN-CM has a wonderful adaptability to the BMS
Company
Modbus
Gateway
Config A/C System via Web
Dimensions
When the Modbus network is set, users can conveniently configure their A/C network system over the
Internet using different TCP/IP browsers.
The Modbus Gateway is designed with a small size.
It’s equipped a installation track for the easy on-site
installation.
10.5
Tracer Summit
Right Side
Front Side
Alerton
4
Schneider
Andover
25.5
10.5
5
83
Johnson
METASYS
110
Honeywell
36
48
3
35
TRACER SUMMT
Installation Track
100
46
84
Accessories
Accessories
BACnet® BMS Gateway
Modbus BMS Gateway
Contains 4 groups of RS485 communication ports and be able to
connect up to 256 indoor units or 128 outdoor units to the BMS.
Be free to connect to the BMS or not.
Supports Modbus protocol networks
Bridges the Carrier central A/C system and the BMS
Establishes a Modbus network comprising up to 1,024 indoor units and 64
outdoor units
Transfers data in RTU mode
Provides a wide voltage range: 12-48V DC
NW-BCN-CM
CRF-18-CM/CRF-18U-CM
Network example
Network example
Indoor Units
Modbus agreement system
XYE
NW-BCN-CM
CRF-30-CM
CRF-30-CM
Indoor units
F1 F2 E
F1,F2,E
HUB
Modbus
Gateway
PQE
XYE
K1,K2,E
Outdoor Units
CRC-10-CM
P,Q,E
Outdoor units
BACnet/IP protocol
X,Y,E
K1,K2,E
XYE
Modbus Master
TCP/IP
Max.64
P,Q,E
Max.64
CRF-30-CM
Indoor units
F1,F2
X,Y,E
K1,K2,E
A+,A-,GND
Web monitoring
system
BMS
K1 K2 E
Modbus
Gateway
CRC-10-CM
Outdoor units
PQE
K1,K2,E
Max.16
Indoor units
Max.64
P,Q,E
CRF-30-CM
Monitoring units online
F1,F2
NW-BCN-CM allows users to track units' operational status and change their running parameters on Internet
Explorer for maximum control convenience
Wide compatibility
1
BMS software
SIMENS
APOGEE
Brand
APOGEE
A N Y W
H E R E
TM
2
TRANE
CRC-10-CM
One Modbus gateway can bridge one refrigerant system with a PC or the Modbus master.
NW-BCN-CM has a wonderful adaptability to the BMS
Company
Modbus
Gateway
Config A/C System via Web
Dimensions
When the Modbus network is set, users can conveniently configure their A/C network system over the
Internet using different TCP/IP browsers.
The Modbus Gateway is designed with a small size.
It’s equipped a installation track for the easy on-site
installation.
10.5
Tracer Summit
Right Side
Front Side
Alerton
4
Schneider
Andover
25.5
10.5
5
83
Johnson
METASYS
110
Honeywell
36
48
3
35
TRACER SUMMT
Installation Track
100
46
84
Accessories
Accessories
3-Phase Protector
LonWorks® BMS Gateway
HWUA/DPB71CM48
NW-LNW-CM
Detect the power condition and make the corresponding protecting action.
Protect the compressor from being damaged.
Automatically distinguish the abnormal power supply conditions and automatically
recover.
Compliance with LonMark protocol,and realizes the management and control of A/C.
Can connect up to 64 indoor units to the BMS.
Realizes non-polarity communication,and also the application can be download online.
Network example
HWUA
DPB71CM48
Excellent reliability
Connection method 1: Suitable for all of air conditioner systems and connect max.64 indoor units.
The protector protects the entire system from power supply problems, and auto restart after recovery.
Specifications
X,Y,E
X,Y,E
X,Y,E
X,Y,E
With over/under voltage function
Model
HWUA
Power supply (V-N-Hz)
2.9 VA
Over voltage
12%
12%
18%
18%
Under voltage
-12%
-12%
-12%
-12%
8%
/
8%
8%
90×69×35
81×67.2×17.5
90×69×35
81×67×35
Phase imbalance
Dimensions(W×H×D)(mm)
System 1
NW-LNW-CM
P,Q,E
RS485
X,Y,E
X,Y,E
X,Y,E
P,Q,E
X,Y,E
X,Y,E
-20 C~50 C
50Hz: -20 C~60 C
60Hz:-20 C~50 C
13 VA
-20 C~50 C
2.9 VA
208~480V-3N 50/60Hz
13 VA
/
81×67.2×17.5
DTS634/DTS636
Calculates power consumption.
Does not need adjusting after long-term use.
Corresponds one outdoor unit to one digital power meter.
The digital power meter consumes minimal energy.
Voltage circuit: less than 2W/10VA
Current circuit: less than 2.5VA
P,Q,E
-20 C ~50 C
DPA51CM44
Digital Power Ammeter
Low power consumption
System 2
DPB71CM48
50Hz: -20 C ~60 C
60Hz:-20 C ~50 C
7 VA
Rated operational power(VA)
Connection method 2: Only suitable for X-power standard system and connect max.64 indoor units.
HWUA
220~480V-3N 50/60Hz 208~480V-3N 50/60Hz 220~480V-3N 50/60Hz 380~480V-3N 50/60Hz
Temp. range( C)
BMS system
DPA53CM23
Without over/under voltage function
System N
Indications and installation
15mm long crack
72
LCD
Impulse
A phase
B phase
C phase
201
RS485
230
NW-LNW-CM
131
145
The digital power meter is tested
after manufacture so it can be
immediately deployment and
used on-site. The LED indicators
and installation schematic are
shown in the figure on the left.
BMS system
Specifications
Specifications
Model
NW-LNW-CM
Model
Dimensions (H*W*D)(mm)
319×251×61
Dimensions (H*W*D)(mm)
Power (V)
85
177~265V AC(50Hz/60Hz)
Power (V)
DTS634/DTS636
230×145×72
200V-500V(50/60Hz)
86
Accessories
Accessories
3-Phase Protector
LonWorks® BMS Gateway
HWUA/DPB71CM48
NW-LNW-CM
Detect the power condition and make the corresponding protecting action.
Protect the compressor from being damaged.
Automatically distinguish the abnormal power supply conditions and automatically
recover.
Compliance with LonMark protocol,and realizes the management and control of A/C.
Can connect up to 64 indoor units to the BMS.
Realizes non-polarity communication,and also the application can be download online.
Network example
HWUA
DPB71CM48
Excellent reliability
Connection method 1: Suitable for all of air conditioner systems and connect max.64 indoor units.
The protector protects the entire system from power supply problems, and auto restart after recovery.
Specifications
X,Y,E
X,Y,E
X,Y,E
X,Y,E
With over/under voltage function
Model
HWUA
Power supply (V-N-Hz)
2.9 VA
Over voltage
12%
12%
18%
18%
Under voltage
-12%
-12%
-12%
-12%
8%
/
8%
8%
90×69×35
81×67.2×17.5
90×69×35
81×67×35
Phase imbalance
Dimensions(W×H×D)(mm)
System 1
NW-LNW-CM
P,Q,E
RS485
X,Y,E
X,Y,E
X,Y,E
P,Q,E
X,Y,E
X,Y,E
-20 C~50 C
50Hz: -20 C~60 C
60Hz:-20 C~50 C
13 VA
-20 C~50 C
2.9 VA
208~480V-3N 50/60Hz
13 VA
/
81×67.2×17.5
DTS634/DTS636
Calculates power consumption.
Does not need adjusting after long-term use.
Corresponds one outdoor unit to one digital power meter.
The digital power meter consumes minimal energy.
Voltage circuit: less than 2W/10VA
Current circuit: less than 2.5VA
P,Q,E
-20 C ~50 C
DPA51CM44
Digital Power Ammeter
Low power consumption
System 2
DPB71CM48
50Hz: -20 C ~60 C
60Hz:-20 C ~50 C
7 VA
Rated operational power(VA)
Connection method 2: Only suitable for X-power standard system and connect max.64 indoor units.
HWUA
220~480V-3N 50/60Hz 208~480V-3N 50/60Hz 220~480V-3N 50/60Hz 380~480V-3N 50/60Hz
Temp. range( C)
BMS system
DPA53CM23
Without over/under voltage function
System N
Indications and installation
15mm long crack
72
LCD
Impulse
A phase
B phase
C phase
201
RS485
230
NW-LNW-CM
131
145
The digital power meter is tested
after manufacture so it can be
immediately deployment and
used on-site. The LED indicators
and installation schematic are
shown in the figure on the left.
BMS system
Specifications
Specifications
Model
NW-LNW-CM
Model
Dimensions (H*W*D)(mm)
319×251×61
Dimensions (H*W*D)(mm)
Power (V)
85
177~265V AC(50Hz/60Hz)
Power (V)
DTS634/DTS636
230×145×72
200V-500V(50/60Hz)
86
Accessories
Remote Alarm Controller
Infrared sensor controller
WR-32-CM
CA-NIM09
Automatically adjust the room environment.
Automatically extend the shutting down time, avoiding frequent ON/OFF.
Graceful appearance accommodates itself to different buildings.
Functions
Simple design
WR-32-CM is specially designed for engineering applications. It does not display the ODU’s working parameters,
but it can connect to the alarm device when ODU is working abnormally, the RUN light will flash.
Installation example
Infrared sensor controller
Specifications
Wired controller
Model
Electrical wiring
Infrared inductive
control box
Wired controller
WR-32-CM
Dimensions (H*W*D)(mm)
CN2
CN1
CA-NIM09/E
S1
150×85×70
CA-NIM09
CA-NIM09
Infrared
sensor
198-242V(50/60Hz)
Power (V)
Display panel
CN3
Network
module port
Display panel port
Wired controller
Indoor main board
Remote controller
Remote controller or wired controller can control indoor unit.
Indoor Unit Group Controller
Specifications
WR-150A-CM
Model
Dimensions(H×W×D)(mm)
Functions
WR-150A-CM is specially designed for X-power indoor units. A group controller can connect up to 16 X-power
indoor units through X1, Y1 and E terminals, but it cannot directly connect to the central controller. If you need to
use a central controller or a PC, you can connect to the XYE from an outdoor unit. A group controller can control
a group of indoor units simultaneously, and query the running status of each unit in the group via the display panel.
System wiring diagram
CA-NIM05
Cooperate with the wired controller to automate control.
Eliminates the need for high voltage power, making the device safe and
steady.
Includes a build-in auto-restart function.
Remote controller or wired controller can control indoor unit.
Installation example
E
Electrical wiring
Outdoor Unit
indoor unit(1#)
X
Y
E
indoor unit (2#)
X
Y
E
indoor unit (3#)
X
Y
E
Hotel card key interface module
indoor unit N# (N≤16)
X
Y
E
Indoor main board
Wired controller
Network module port
Wired controller
PQE
WR-150A-CM
16#
indoor unit(1#)
indoor unit (2#)
indoor unit (3#)
indoor unit N# (N≤16)
XYE
CA-NIM05
E
X
Y
E
X
Y
E
X
Y
E
X
Y
Check
Hotel Card-inserter
POWER
X
Y
Display panel
CA-NIM05
CA-NIM05
CN1
X
Display panel port
Y
DC 5V
Hotel Card Key Interface Module
PQE
X
Senor part: 46×30×25.6, Control box: 86×72.8×15.5
Power
Simple design
WR-150A-CM
1#
CA-NIM09
Y
E
E
NOTE :
The Maximum Number
of Indoor units is 64.
Card key
5 meters
RUN
Wired controller
CN2
COM1
GND
To hotel
control system
Remote controller
Centr alized contr oller
Specifications
Specifications
Model
WR-150A-CM
Dimensions (H*W*D)(mm)
Power (V)
87
150×85×70
198-242V(50/60Hz)
Model
Dimensions (H*W*D)(mm)
Power (V)
CA-NIM05
86×72.8×15.5
DC 5V
88
Accessories
Remote Alarm Controller
Infrared sensor controller
WR-32-CM
CA-NIM09
Automatically adjust the room environment.
Automatically extend the shutting down time, avoiding frequent ON/OFF.
Graceful appearance accommodates itself to different buildings.
Functions
Simple design
WR-32-CM is specially designed for engineering applications. It does not display the ODU’s working parameters,
but it can connect to the alarm device when ODU is working abnormally, the RUN light will flash.
Installation example
Infrared sensor controller
Specifications
Wired controller
Model
Electrical wiring
Infrared inductive
control box
Wired controller
WR-32-CM
Dimensions (H*W*D)(mm)
CN2
CN1
CA-NIM09/E
S1
150×85×70
CA-NIM09
CA-NIM09
Infrared
sensor
198-242V(50/60Hz)
Power (V)
Display panel
CN3
Network
module port
Display panel port
Wired controller
Indoor main board
Remote controller
Remote controller or wired controller can control indoor unit.
Indoor Unit Group Controller
Specifications
WR-150A-CM
Model
Dimensions(H×W×D)(mm)
Functions
WR-150A-CM is specially designed for X-power indoor units. A group controller can connect up to 16 X-power
indoor units through X1, Y1 and E terminals, but it cannot directly connect to the central controller. If you need to
use a central controller or a PC, you can connect to the XYE from an outdoor unit. A group controller can control
a group of indoor units simultaneously, and query the running status of each unit in the group via the display panel.
System wiring diagram
CA-NIM05
Cooperate with the wired controller to automate control.
Eliminates the need for high voltage power, making the device safe and
steady.
Includes a build-in auto-restart function.
Remote controller or wired controller can control indoor unit.
Installation example
E
Electrical wiring
Outdoor Unit
indoor unit(1#)
X
Y
E
indoor unit (2#)
X
Y
E
indoor unit (3#)
X
Y
E
Hotel card key interface module
indoor unit N# (N≤16)
X
Y
E
Indoor main board
Wired controller
Network module port
Wired controller
PQE
WR-150A-CM
16#
indoor unit(1#)
indoor unit (2#)
indoor unit (3#)
indoor unit N# (N≤16)
XYE
CA-NIM05
E
X
Y
E
X
Y
E
X
Y
E
X
Y
Check
Hotel Card-inserter
POWER
X
Y
Display panel
CA-NIM05
CA-NIM05
CN1
X
Display panel port
Y
DC 5V
Hotel Card Key Interface Module
PQE
X
Senor part: 46×30×25.6, Control box: 86×72.8×15.5
Power
Simple design
WR-150A-CM
1#
CA-NIM09
Y
E
E
NOTE :
The Maximum Number
of Indoor units is 64.
Card key
5 meters
RUN
Wired controller
CN2
COM1
GND
To hotel
control system
Remote controller
Centr alized contr oller
Specifications
Specifications
Model
WR-150A-CM
Dimensions (H*W*D)(mm)
Power (V)
87
150×85×70
198-242V(50/60Hz)
Model
Dimensions (H*W*D)(mm)
Power (V)
CA-NIM05
86×72.8×15.5
DC 5V
88
CAD Version
Accessories
AHU Control Box
AHUKZ-01B/AHUKZ-02B/AHUKZ-03B
X-Power Standard functions inside.
Can be used to connect VRF outdoor units with DX AHU or other brand indoor units
Introduction
AutoCAD add-on software
Automatic Calculation: Refrigerant & drain pipe size
Automatic Selection: Distributor kit & branch joint
System Check: Installation regulation & refrigerant addition
Automatic Report: Piping installation diagram, equipment list & quotation
AHUKZ-01B/AHUKZ-02B/AHUKZ-03B is an independent control box that can connect a AHU to X-Power
system to realize centralized control with X-Power system. Control box wiring is as follows:
Maximum 4 AHU Control Box can be parallel installed to one 3rd party indoor unit.
Power supply
Power supply
Centralized Controller
P/Q/E
X/Y/E
Wired Controller
T1/T2/T2B/T2C
G/L pipe
Fan/pump
x
EXV
Power supply
DX AHU or other brand indoor units
Selection software
To meet consultants’ and distributors’ requirements, Carrier has developed an advanced design automation tool that
can be used in AutoCAD-based CAD version or Windows-based Sales version. The software provides quick and
convenient selectable options for users, supports multiple languages, and greatly improves the selection process.
Windows Version
Load calculation:Provides two calculation methods (detailed room load calculation and rough load calculation).
Indoor & outdoor units selection: There are versatile indoor units and different outdoor units for choosing.
Piping drawing: Displays the detailed layout of an A/C system and the parameters for piping and branch distributors.
Controller selection: Provides a selection of controllers for indoor units and outdoor units, including wireless and
remote controllers for indoor units.
Report output: Outputs a comprehensive selection report as a Word or PDF document.
89
90
CAD Version
Accessories
AHU Control Box
AHUKZ-01B/AHUKZ-02B/AHUKZ-03B
X-Power Standard functions inside.
Can be used to connect VRF outdoor units with DX AHU or other brand indoor units
Introduction
AutoCAD add-on software
Automatic Calculation: Refrigerant & drain pipe size
Automatic Selection: Distributor kit & branch joint
System Check: Installation regulation & refrigerant addition
Automatic Report: Piping installation diagram, equipment list & quotation
AHUKZ-01B/AHUKZ-02B/AHUKZ-03B is an independent control box that can connect a AHU to X-Power
system to realize centralized control with X-Power system. Control box wiring is as follows:
Maximum 4 AHU Control Box can be parallel installed to one 3rd party indoor unit.
Power supply
Power supply
Centralized Controller
P/Q/E
X/Y/E
Wired Controller
T1/T2/T2B/T2C
G/L pipe
Fan/pump
x
EXV
Power supply
DX AHU or other brand indoor units
Selection software
To meet consultants’ and distributors’ requirements, Carrier has developed an advanced design automation tool that
can be used in AutoCAD-based CAD version or Windows-based Sales version. The software provides quick and
convenient selectable options for users, supports multiple languages, and greatly improves the selection process.
Windows Version
Load calculation:Provides two calculation methods (detailed room load calculation and rough load calculation).
Indoor & outdoor units selection: There are versatile indoor units and different outdoor units for choosing.
Piping drawing: Displays the detailed layout of an A/C system and the parameters for piping and branch distributors.
Controller selection: Provides a selection of controllers for indoor units and outdoor units, including wireless and
remote controllers for indoor units.
Report output: Outputs a comprehensive selection report as a Word or PDF document.
89
90
Branch Pipe
Branch joints of two-pipe refrigerant system
Model
Branch Pipe
Branch joint for
R410A outdoor unit
Branch joint for R410A
indoor unit
Appearance
Model name
Packing Size
(mm)
Gross
Weight
(kg)
BJC-02-CM(i)
255×150×185
1.5
For two outdoor
units connection
BJC-03-CM(i)
345×160×285
3.4
For three outdoor
units connection
BJC-04-CM(i)
475×165×300
4.8
For four outdoor
units connection
BJF-224-CM(i)
90×105×100
0.4
A*<16.6kW
BJF-330-CM(i)
290×105×100
0.6
16.6≤A*<33kW
BJF-710-CM(i)
310×130×125
0.9
33kW≤A*<66kW
BJF-1344-CM(i)
350×180×170
1.5
66kW≤A*<92kW
BJF-E1344-CM(i)
365×195×215
1.9
92kW≤A*
Description
A*:The total capacity of indoor units which is connected to this branch joint
91
92
Branch Pipe
Branch joints of two-pipe refrigerant system
Model
Branch Pipe
Branch joint for
R410A outdoor unit
Branch joint for R410A
indoor unit
Appearance
Model name
Packing Size
(mm)
Gross
Weight
(kg)
BJC-02-CM(i)
255×150×185
1.5
For two outdoor
units connection
BJC-03-CM(i)
345×160×285
3.4
For three outdoor
units connection
BJC-04-CM(i)
475×165×300
4.8
For four outdoor
units connection
BJF-224-CM(i)
90×105×100
0.4
A*<16.6kW
BJF-330-CM(i)
290×105×100
0.6
16.6≤A*<33kW
BJF-710-CM(i)
310×130×125
0.9
33kW≤A*<66kW
BJF-1344-CM(i)
350×180×170
1.5
66kW≤A*<92kW
BJF-E1344-CM(i)
365×195×215
1.9
92kW≤A*
Description
A*:The total capacity of indoor units which is connected to this branch joint
91
92
R410A DC Inverter VRF
Series 50/60Hz
Carrier InterAmerica Corporation (CIAC)
10801 NW 103rd Street Suite 1, Miami, FL 33178
www.carriercca.com
Carrier X-power VRF 2015
Cat-v.01
VRF Series 60 Hz and 50 Hz
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement