Warmzone Product Catalog
P
R
O
D
U
C
T
C A T A L O G
PL.PC.v1.3.15
Toll Free: 866.676.9276
WWW.PROLINERADIANT.COM
[email protected]
National Association of
Custom Home Builders
“Vendor of the Year.”
About ProLine Radiant
General Information - Products and Services
ProLine Radiant is a leading international provider of interior and exterior radiant heat solutions.
Our wide selection of products and unsurpassed customer services have established ProLine as the
trusted radiant heat solutions provider. From large commercial applications to custom residential
projects, ProLine Radiant has the top products, services and professional staff to provide the ideal
radiant heat solution.
ProLine Radiant Heat Solutions Include:
Industrial, Commercial and Residential Solutions
Snow and Ice Melting
ProLine is with you every step of the way;
from initial consultation and project
analysis to system design, purchase
and installation.
Radiant Floor Heating
Roof Deicing and Gutter Melt
Pipe Tracing
System Design and Engineering
Installation Support and Training
Summary of Benefits
Electric and Hydronic Radiant Solutions
ProLine Radiant includes complete engineering and design
services with each system. You’ll find our professional staff
to be extremely knowledgeable, friendly, and responsive.
From project inception to completion, we will work with
you to ensure that all your project needs are met.
The Complete Solution and Best Value
ProLine Radiant offers more than the latest industryleading radiant heat products. We partner with you
to install the best radiant heat system for your needs
and budget. In addition to top quality products, ProLine
includes unmatched system design/layout and engineering
services, as well as expert installation support.
Our superior customer and installation services are why
ProLine has gained its reputation as a trusted leader in
radiant heat solutions. When it comes to the complete
radiant heat solution, you won’t find a wider selection of
proven products or a more knowledgeable, helpful and
friendly staff.
“The staff at ProLine was by far the most
professional, responsive and knowledgeable of all those with whom I dealt.”
Benson R. - TileMaster (Business Owner)
ProLine makes the process of selecting, purchasing and
installing a radiant heat system as seamless as possible.
2
Toll Free: 866.676.9276
Our expertise and superior service are just some of the
reasons why construction professionals and homeowners
alike consistently choose ProLine.
Call a radiant heat expert at ProLine for a free consultation.
Or visit the ProLine Radiant website (www.prolineradiant.
com) and then call us toll free at 866.676.9276 to learn
more about your radiant heat options.
• Free Consultation and Analysis with an Experienced,
Unbiased Radiant Heat Expert
• Wide Selection of Proven Products
• Complete System Design (AutoCAD) and
Engineering Services
• Industry Leading Electric and Hydronic Radiant
Heating Solutions
• Post-sales Technical Support
• Expert Installation Support
• Professional Training
• Free Quote Services
Contact your local wholesaler. If they don’t carry ProLine
products, be sure to ask them to!
To receive a radiant heat quote, or design, contact your
local wholesaler or visit www.prolineradiant.com. Or for
more information, call ProLine Radiant at 866.676.9276
today.
To submit your project for a design/quote, fax your
project information to ProLine Radiant at 801.948.7599.
www.prolineradiant.com
[email protected]
ProLine Radiant Product Catalog
Contents
General Information - Products and Services.........................2
Project Photos.......................................................................................4
Professional Customer Services..................................................6
ProLine Design/Layout Services............................................................7
ProLine Snow Melting Systems...................................................9
Snow Melting System Overview..........................................................11
Exterior Radiant Heat Controls............................................................13
Activation Devices (Snow Sensors).....................................................15
Pipe Trace Solutions......................................................................17
Pre-terminated Heat Trace Cable........................................................18
PLSR Self-Regulating Heat Trace Cable...............................................19
Self-Regulating Heat Cable - Product Comparison..............................20
Pipe Trace Cable Accessories and Controls.........................................21
Roof Deicing and Gutter Melting..............................................23
Self-Regulating Heat Cable - Product Comparison..............................26
Low-Voltage Roof Deicing Systems..........................................29
Radiant Floor Heating...................................................................31
Slab/Storage Floor Heating Cable.......................................................34
FoilHeat...............................................................................................35
Radiant Heat Controls.........................................................................37
Thermostats........................................................................................38
Hydronic Radiant Heat Systems................................................39
With its focus on preeminent customer service and a wide
offering of proven products, ProLine Radiant has established
itself as a leading provider of complete interior and exterior
radiant heat solutions throughout the United States and Canada.
ProLine Radiant Location and Contact Information
Address:
Phone:
12637 South 265 West, Suite 100AToll Free: 866.676.9276
Draper, UT 84020
Fax: 801.948.7599
Email and Internet:
[email protected]
www.prolineradiant.com
ProLine Radiant
products have been
featured on:
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 3
Snow Melting, Pipe Tracing,
Roof Deicing, and
Floor Heating Solutions
Project Photos
ProLine floor heating mats.
ProLine roof deicing heat cable installed in
commercial gutter melt application.
ProLine heated driveway.
ProLine radiant floor heating mats shown under
ceramic tile for heated floor.
4
Toll Free: 866.676.9276
ProLine low-voltage roof deicing system heating
roof valley and edges.
www.prolineradiant.com
[email protected]
Roof deicing system heating roof edges.
ProLine heat cable embedded in city sidewalks.
Heated tire tracks in asphalt driveway.
Pipe tracing system installed.
Toll Free: 866.676.9276
ProLine snowmelt system installed in parking lot ramp.
ProLine snow melting system installed in paver driveway.
www.prolineradiant.com
[email protected] 5
Professional System Design,
Installation Training, and
Technical Support Services
ProLine’s Unparalleled Customer Services
What truly differentiates ProLine Radiant from the competition is its customer service.
In addition to its experienced design team providing detailed AutoCAD layouts, ProLine
offers free installation training courses with certificates of completion. And should you
need, ProLine electricians and designers are also on hand to provide technical support
during the installation process. We work with you every step of the way to make the
process of installing a radiant heat system as easy as possible.
Professional Design
Services
ProLine custom designs each
radiant heat system to ensure
it meets each project’s specific
needs. The AutoCAD layouts
contain all the specs and
information necessary, so you’ll
know all the technical information,
including load calculations, breaker
sizes, number of breakers, etc.,
prior to any installation taking
place.
ProLine Radiant
Training Services
A radiant heating system is only
as good as the installation - which
is why ProLine provides a valuable
installation training program.
ProLine’s professional training
services include courses on radiant
snowmelt, roof deicing and floor
heating system installation.
Installers who successfully complete the training recieve
a dated certificate from ProLine, documenting their
expertise in radiant heat installation.
Installation Support Services
ProLine Radiant’s installation support services further
distinguish it from other manufacturers and wholesale
distributors. ProLine Radiant provides a dedicated staff of
experts to assist you throughout the installation process
if you need. This valuable resource gives your business
a wealth of expertise to draw from and helps to ensure
timely, successful installations - and repeat business.
6 Toll Free: 866.676.9276
ProLine offers free
installation training as
well as professional
design/layout services
and installation support.
When you work with ProLine, you are partnering with
experienced professionals who stand beside you
throughout the purchase, design, and installation
process. Our goal is to make the installation of radiant
heat as easy as possible for you and ensure the success
of your business. Enhance your bottom line with peace
of mind by utilizing the trusted services and expertise of
seasoned professionals whose goal is your success.
www.prolineradiant.com
[email protected]
ProLine Provides
Engineering and Shop
Drawings
Professional Design Services
ProLine snowmelt system layout.
ProLine floor heating system layout.
Roof deicing system layout.
Imagine
complete
system layouts
and installation
support with
each job!
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 7
Heated Driveway Design and Installation
AutoCAD Design and Installation of Heated Paver Driveway
12637 South 265 West, Suite #100A
Draper, UT 84020 USA
Phone: 801.948.7600
Fax: 801.948.7599
Toll free: 866.676.9276
8 Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 9
Fully automated, maintenance-free ProLine snow melting systems have proven to be the
optimum solution for heating commercial parking ramps, driveways, sidewalks, loading docks
and more. Versatile and durable, ProLine heat cable is designed to withstand the stress of heavy
concrete pours, brick and stone paver applications as well as the extreme temperatures of hot
asphalt installations. The snow melting cable is available on the spool or pre-spaced in mats for
easy “roll-out” installation. The performance and reliability of electric snowmelt systems have
made ProLine Radiant a favorite among wholesalers and professional builders alike.
Features Include:
• Available on the spool or pre-spaced in mats.
• Single-point connection simplifies installation.
• Twin-conductor cable.
• Flexible installation; easy to customize.
• Durable and versatile - Designed for use in concrete,
under pavers, and hot asphalt applications.
• Silent, efficient and safe.
• Maintenance free operation.
• All mats heat 2-feet wide. Power leads are
16.4 feet in length.
• 10-year limited warranty against manufacturing defects.
ProLine Mats and Cables Specifications
Cable construction
Twin conductor
Rated voltage
120-600 V (For 120, 208, 277, 600 V, please call.)
Output (mats)
37W/ft.2 and 50W/ft.2
Output (cables)
12W/ft. (40W/m) with cable, 24-70W/ft.2
Cold lead
16.4 feet (5.0m) Longer cold leads available on request.
Bending radius
Minimum 2 inches, (51mm)
Cable diameter
¼ inches (7mm)
Conductor insulation
Fluoropolymer
Metal sheath
Copper
Outer sheath
Polyolefin
Max. external jacket
asphalt temperature *
220°F (105°C) *[460°F (240°C) for up to 10 minutes]
Max. External jacket temp. 158°F (70°C)
Max. conductor insulation
temperature
302°F (150°C) Concrete and pavers
Min. installation temp.
5°F (-15°C)
10 Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
ProLine Snow Melting
System Overview
Snow Melting
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 11
PROLINE SNOW MELTING MATS AND CABLE ORDERING INFORMATION *
The ProLine snow melting system includes heating cable or a mat that is pre-spaced and taped into a 3- or
4-inch on-center-mat that allows for simple roll-out installation. All mats heat 2-feet wide. Power leads are
16.4 feet in length.
Snow Melting Mats
240 Volt Mat (50 W per square foot)
Item Number
Heated
Area
(Sq. ft.)
Mat
Length
(Feet)
Watts
Amps
240 Volt Mat (37 W per square foot)
Item Number
Ohms
Heated
Area
(Sq. ft.)
Mat
Length
(Feet)
Watts
Amps
Ohms
SM25052500
10
5
500
2.1
115.2
SM237112750
20
11
750
3.1
76.8
SM2501121000
20
11
1,000
4.2
57.6
SM2373022000
55
30
2,000
8.3
28.8
SM2502722500
50
27
2,500
10.4
23.1
SM2375123500
95
51
3,500
14.6
16.5
SM2504424000
80
44
4,000
16.7
14.4
SM2376524500
120
65
4,500
18.8
12.8
SM2506025500
110
60
5,500
22.9
10.5
SM2378025500
150
80
5,500
22.9
10.5
480 Volt Mat (50 W per square foot)
Item Number
Heated
Area
(Sq. ft.)
Mat
Length
(Feet)
Watts
Amps
Ohms
480 Volt Mat (37 W per square foot)
Item Number
SM437112750
Heated
Area
(Sq. ft.)
Mat
Length
(Feet)
Watts
Amps
Ohms
10
11
750
3.1
307.2
SM45052500
10
5
500
1.0
460.8
SM4501121000
20
11
1,000
2.1
230.4
SM4373022000
55
30
2,000
8.3
115.2
SM4502722500
50
27
2,500
5.2
92.2
SM4375123500
95
51
3,500
14.6
65.8
SM4504424000
80
44
4,000
8.3
57.6
SM4376524500
120
65
4,000
18.8
51.2
SM4506025500
110
60
5,500
11.5
41.9
SM4378025500
150
80
5,500
22.9
41.9
Snow Melting Cable
240 Volt Cable (37 and 50 W per square foot)
Approximate Heat Coverage
(Square feet)
Item Number
Cable
Length
(Feet)
SC2841000
84
20
SC21682000
168
SC22092500
209
SC23754500
SC24585500
Watts
Amps
Ohms
27
1,000
4.2
57.6
40
56
2,000
8.3
28.8
50
67
2,500
10.4
23.1
375
90
120
4,500
18.8
12.8
458
110
150
5,500
22.9
10.5
3-inch
spacing
(50 Watts Sq. ft.)
4-inch
spacing
(37 Watts Sq. ft.)
Snow Melting Mats for Asphalt
240 Volt (37 W per square foot)
Item Number
Heated Area
(Sq. ft.)
Mat Length
(Feet)
SMA237112750
20
11
Watts
750
Amps
Ohms
3.1
76.8
28.8
SMA2373022000
55
30
2,000
8.3
SMA2375123500
95
51
3,500
14.6
16.5
SMA2376524500
120
65
4,500
18.8
12.8
SMA2378025500
150
80
5,500
22.9
10.5
* For 120, 208, 277, 600 V, please call ProLine (866.676.9276).
12
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Contactor Panels (with GFEP)
In keeping with its commitment to provide professional builders with the best products,
service and convenience, ProLine Radiant snowmelt systems include GFEP (ground fault
equipment protection) breakers with its panels, saving installers time and money.
Designed for radiant snow and ice melting
applications, the ProLine Radiant contactor panel
with GFEP simplifies your installation and minimizes
costs. The UL listed panels feature a NEMA 4
enclosure, terminal connection block, two or four
3-pole contactors, and wiring diagram.
The panel should be used in conjunction with the
in-ground snow sensor/controller or the aerial-mount
snow switch (see pages 14-15).
NEMA 4X contactor panel available upon request.
Control Panel with GFEP
Features and Benefits
NEMA 4, UL listed panel box
Low cost
Easy to install
Integrated 30mA GFEP (optional)
LED trip indicator (internal)
LED “heat on” indicator light
Pre-wired terminal connections
120 V on/off remote heat indicator
2-year warranty
Control panel opened.
Control panel front.
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 13
Snow Melting
Exterior Radiant Heat Controls
Exterior Radiant Heat Controls
Snowmelt System Controller
The ProLine snowmelt control units are NEMA 1, wall-mounted control panels. The approximate
size of the control unit is only 6x3½ inches. It is even possible to control the unit from an external
signal (day/week timer, GSM-module or other signal source). The controller also features manual
override capability, allowing you to activate the system to melt snow drifts or ice that has formed
due to wind or shade.
ProLine Control Unit
The ProLine Radiant controller is designed for ice and snow melting in gutters and
ground areas. Using readings from temperature and moisture sensors, the controller
ensures economical control of power consumptions when keeping outdoor areas and
roofs free of ice and snow.
Despite the control unit’s advanced technology, compact size and ease of use, it
also represents a breakthrough in that it is significantly cheaper than most other
industry controllers. The
Technical Data for ProLine
unit provides maintenance-free, energy-efficient, UL listed
In-Ground Sensors
snow melting for all types of residential and commercial
applications.
Detecting
Moisture and temperature
ProLine Snowmelt Controller Technical Data
Supply voltage
120/230 V ±10%, 50-60 Hz
Temperature range
32°F to 122°F (0 to 5°C)
Working range
-4°F to 41°F (-20 to 5°C)
Built-in timer for manual
snow melting / after run
1-6 hours
Output relay
3 x 16A potential free relay
Two zone application
Output is 2 x 16A potential
free relay
Water-based system
Controlling a 3 or 4 way
valve, primary pump,
secondary pump.
Display
Graphic and with backlight
Ambient temperature
32°F to 122°F (0°-50°C)
Housing (including cover)
IP20
Weight
1.09 lbs. (495 g)
Dimensions
(excluding cover)
H: 3.5” W: 6.1” D: 1.7”
(90mm x 156mm x 45mm)
Dimensions
(including cover)
H: 6.7” W: 6.4” D: 1.7”
(170mm x 162mm 45mm)
LEDs indicate the
functions:
ON/green; ERROR/red
Supply voltage to the
thermostat; fault indication
14 Toll Free: 866.676.9276
Mounting
Any outdoor area
Housing
IP68
Ambient temperature
-4°F to 158°F (-20 to 70°C)
Cable length
33 feet (10 meters)
Dimensions
H: 1¼-2.4 inches
(32mm-60.9mm)
Ground Sensor for Temperature and Moisture
Designed for embedding into the surface of concrete,
asphalt, pavers or other outdoor surface, ProLine
Radiant’s in-ground snow sensor detects ground
temperature and moisture for automated snow melting
systems. The activation device only signals the controller
to activate the system when the outdoor temperature is
below the selected setting and snow or ice occurs on the
sensor head.
The snow sensor is usable for all applications within
hydronic as well as
electrical heating.
Optimal operation is
ensured because of
the output control,
which makes the
system both effective
and economical.
www.prolineradiant.com
In-ground snow sensor (and sensor cup)
for automated snow melting system.
[email protected]
ProLine System Activation Devices (Snow Sensors)
ProLine Radiant snowmelt systems come standard with an aerial or ground-mounted snow sensor
switch. This sophisticated device automatically activates the ProLine snow melting system when
it detects precipitation and temperatures are below a set point. The temperature is typically
set at 39°F, but is adjustable from 34°F (1.1°C) to 44°F (6.6°C). Smart system compatible, the
aerial sensors have several other notable features, including adjustable delay off cycle and
upgradeable remote activation.
The unit is easy to install and all the electronics can be accessed by simply removing the
four front cover screws.
Reliable Rain and Snow Detection Adjustable Delay Off Cycle Easy Installation & Full Access to Electronics
Adjustable Temp. Trigger Point (34°-44°F)
Smart “Manual On” Operates for one Delay
Full 30A @ 240 VAC Control
Field Strap for 100-120 / 200-240 VAC Operation
Selectable Low-Temperature Cutoff
Replaceable Remote Precipitation Sensor
Housed in a two-gang PVC enclosure
The WS-5 Aerial Snow Sensor - The WS-5 is essentially a WS-2C fitted with a dual 30A
@ 240 VAC load control contact set. It is primarily designed for larger satellite antenna/
broadcast tower deicing and pavement snow melting applications. Specifically, any job
that a WS-2C can perform, a WS-5 can perform with double the load handling capability.
The unit is housed in a two-gang PVC enclosure. The overall dimensions of the WS-5 are
4¾” x 7” x 2¾” (120mm x 178mm x 70mm). The unit weighs 2 pounds. The user may
access all electronics by removing the four front cover screws.
Reliable Rain and Snow Detection Dual 30A @ 240 VAC Control
Adjustable Delay Off Cycle Field Strap for 100-120 / 200-240 VAC Operation
Easy Installation & Full Access to Electronics
Selectable Low-Temperature Cutoff
Adjustable Temperature Trigger Point
Replaceable Remote Precipitation Sensor
Smart “Manual On” Operates for one Delay
Housed in a two-gang PVC enclosure
The WS-8 Aerial Snow Sensor - The WS-8 is primarily designed for gutter, downspout,
and roof ice melting and small satellite antenna deicing. The totally sealed, low voltage,
remote mount precipitation sensor allows the user to install the small sensor head in a
downspout, the bottom of a gutter, or at the end of an antenna boom, up to 10 feet away,
while keeping the main controller in a more convenient or protected location.
Reliable Rain and Snow Detection Full 30A @ 240 VAC Control
Adjustable Delay Off Cycle Field Strap for 100-120 / 200-240 VAC Operation
Easy Installation & Full Access to Electronics Safe Low-Voltage Sensor Head
Adjustable Temperature Trigger Point
Replaceable Remote Precipitation Sensor
Bright Off/On/Triggered LED Status Indicator Smart “Manual On” Operates for one Delay Cycle
The WS-AUX Control Panel - The WS-AUX Control Display Panel is used in conjunction
with a WS Snow Sensor Controller. The sensor is typically mounted on a roof, near a gutter,
or in a similarly difficult location to reach. The WS-AUX provides a method of remotely
monitoring and controlling the attached sensor. The user may monitor both the operating
mode and the activation state of the sensor. The user may also set the sensor to prohibit
automatic operation, to automatically operate, or to manually operate one snow melting
cycle, then return to automatic operation. The WS-AUX derives its power from the snow
sensor and requires no batteries or AC power. With an operating temperature range of
-40°F to 185°F (-40°C to +85°C) the WS-AUX is designed for use either indoors or outdoors
with proper protection from the elements.
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 15
Snow Melting
The WS-2C Aerial Snow Sensor - Designed for snow and freezing rain detection, the
WS-2C aerial snow sensor sets the standard for automated radiant snowmelt systems.
The snow sensor activates the snow melting system when moisture is present and the
temperature reaches the set point (usually 39°F), providing fully automated, efficient
snow and ice melting.
ProLine Snowmelt System Activation Devices
Technical Data and Specifications
WS-2C Specifications
Dimensions
4¾"x7"x2¾" (120mm x 178mm x 70mm)
Weight
2 lbs. (0.9 Kg)
Operating
temperature
-40° to 185°F (-40° to 85°C)
Enclosure rating
NEMA 3R
Supply power
100-120 VAC / 200-240 VAC
Field selectable 15 W maximum
Trigger temperature
34° to 44°F (1.1° to 6.6°C)
Field selectable
Delay off (sensor)
2 Minutes
Delay off (controller)
30-90 Minutes field selectable
Load contact capacity
30A @ 240 VAC / 100,000
Operations at full load
Monitor contact
capacity
24 VDC/VAC 400mA 10 W Total
WS-5 Specifications
Dimensions
4¾”x7”x2¾” (120mm x 178mm x 70mm)
Weight
2 lbs. (0.9 Kg)
Operating
temperature
-40° to 185°F (-40° to 85°C)
Enclosure rating
NEMA 3R
Supply power
100-120 VAC / 200-240 VAC
Field selectable 15 W maximum
Trigger temperature
34° to 44°F (1.1° to 6.6°C)
Field selectable
Delay off (sensor)
2 Minutes
Delay off (controller)
30-90 Minutes field selectable
Load contact capacity
2x30A @ 240 VAC / 100,000
Operations minimum at full load
Monitor contact
capacity
24 VDC/VAC 400mA 10 W Total
ProLine WS-AUX Snow Sensor
Control/Display Panel
The WS-AUX control
display panel
brings control and
monitoring of your
snowmelt system
indoors. No need to
hope that the system
has successfully
triggered. One glance
at the WS-AUX
confirms it.
The WS-AUX is
compatible with
the WS-2C, WS-5,
and WS-8 rain/snow
sensor controllers.
The unit consists of
an electronic printed
circuit board mounted
securely to a steel
mounting plate. The
overall dimensions of
the WS-AUX are 4.1”x
1.8” x 0.9” (104mm
x 45mm x 23mm).
The unit weighs 2.5
ounces. The WS-AUX
fits into a standard
single-gang or multi-gang electrical enclosure.
Compatible self-threading mounting screws that
fit both metal and plastic enclosures are included.
The plate also has mounting holes for a rectangular
“modular” cover plate. This allows the user to select
a cover plate color and material that blends with the
decor of the room.
WS-8 Specifications
Dimensions
4¾”x7”x2¾” (120mm x 178mm x 70mm)
Weight
2 lbs. (0.9 Kg)
Operating
temperature
-40° to 185°F (-40° to 85°C)
Enclosure rating
NEMA 3R
Supply power
100-120 VAC / 200-240 VAC
Field selectable 15 W maximum
Trigger temperature
34° to 44°F (1.1° to 6.6°C)
Field selectable
Delay off
30-90 Minutes field selectable
Load contact capacity
30A @ 240 VAC / 100,000
Operations minimum at full load
16 Toll Free: 866.676.9276
ProLine radiant snow melting system with aerialmount snow sensor installed at roof’s edge.
www.prolineradiant.com
[email protected]
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 17
Pipe Trace Solutions
Pre-terminated Heat Trace Cable
ProLine’s self-regulating pipe tracing cable is an ideal solution for industrial, commercial and
residential pipe freeze protection as well as process temperature maintenance. The durable heat
cable can be installed in industrial, commercial and residential pipe trace applications.
ProLine Radiant’s easy-to-use pipe tracing systems
feature pre-terminated heat cable that is available with
or without a ground fault circuit interupter. In addition to
pipe freeze protection, ProLine pipe trace systems can
also be used for process temperature maintenance applications where viscosity control at higher temperatures is
required.
ProLine offers a range of pipe trace cable that can be
used in a variety of industrial hazardous, non-hazardous
and commercial applications. Heat tracing can be used in
commercial, residential, and industrial applications with
both metal and plastic piping.
Industrial pipe tracing application.
The self-regulating cable adjusts heat output in response
to ambient temperatures, so when the temperature rises,
the electrical resistance increases and the consumption
of electricity decreases, ensuring safe, energy-efficient
operation. The cable will not overheat or burnout - even
when touching or overlapping.
Also, because of the self-regulating properties, a thermostat may not be necessary in some applications. ProLine
Radiant heat cable is resistant to watery and inorganic
chemicals and protected against abrasion and impact
damage.
ProLine Radiant’s self-regulating heat cable on spools.
18 Toll Free: 866.676.9276
The termination, power connection, splice, tee, and end
seal kit reduces installation time and requires no special
skills or tools.
www.prolineradiant.com
[email protected]
Pipe Trace Solutions
(PLSR Heat Cable)
ProLine’s self-regulating (PLSR), parallel heating pipe trace cable is designed for a variety of
industrial applications and environments, including explosion-hazardous and nonhazardous areas
up to a maximally admissible work-place temperature of +149°F (65°C). The UL listed cable can
be used for plastic or metal pipe freeze protection and flow maintenance of pipes, tanks, and
valves. The cables are available on spools in lengths of 250’ / 500’ / 1000’ in 120, 208, 240, and
277 volts, and in pre-assembled lengths in 120 volts.
Features and Benefits
PLSR Technical Data
• Energy Efficient - Automatically varies its power output in response to pipe temperature changes.
• Easy to Install - Can be cut to any length required on
site (up to max circuit length) so there’s no wasted
cable.
• Safe / Durable – Does not overheat or burn out, even
when touching or overlapping.
• Versatile – Suitable for plastic or metal pipes, gutters
and downspouts, and for use in non-hazardous, hazardous and corrosive environments.
110-120, 208-277 V
Maximum maintain or
continuous exposure temperature (power on)
149°F (65°C)
Maximum intermittent exposure temperature 1,000
hours (power on or off)
-40° to 185°F (-40° to 85°C)
Minimum installation
temperature
-40°F (-40°C)
Protective braid resistance
< 18.2Ω/km
Bus wire gauge
16 AWG
Approvals
UL Listed; hazardous
Certifications
Class I, Div.2 Groups A,B,C,D
Class II, Div.2 Groups F,G
Class III
• Easy Install – The power connection, splice, tee and
end seal kit will reduce installation time.
Pipe Tracing
• Low Cost – Less installation cost than steam tracing;
less maintenance expense and less downtime.
Service voltage
• Optional Outer Jacket - Makes the heating cable resistant to watery and inorganic chemicals and protects
against abrasion and impact damage.
• 10-year warranty - NOT PRORATED
• Pre-assembled cable includes a 3-foot power cord and
plug.
Maximum Circuit Length at Circuit Breaker Size
Cable
Startup Temp.
Breaker Size
PLSR-120-5
and
PLSR-240-5
PLSR-120-8
and
PLSR-240-8
PLSR-120-10
and
PLSR-240-10
PLSR-120-12
and
PLSR-240-12
120 V
240 V
15 A
20 A
30 A
40 A
15 A
20 A
30 A
40 A
50°F (+10°C)
200
200
200
200
498
530
530
530
32°F (0°C)
190
200
200
200
429
505
505
505
-4°F (-20°C)
165
200
200
200
337
433
480
480
-40°F (-40°C)
140
190
200
200
255
328
400
400
50°F (+10°C)
145
150
150
150
354
406
420
420
32°F (0°C)
125
150
150
150
291
360
360
360
-4°F (-20°C)
110
145
150
150
183
229
350
350
-40°F (-40°C)
95
130
150
150
164
206
275
320
50°F (+10°C)
100
130
130
130
242
295
315
360
32°F (0°C)
90
120
130
130
177
216
246
315
-4°F (-20°C)
80
110
130
130
131
164
215
215
-40°F (-40°C)
75
100
130
130
114
141
170
215
50°F (+10°C)
100
130
130
130
183
229
229
240
32°F (0°C)
90
120
130
130
124
160
180
210
-4°F (-20°C)
80
110
130
130
91
124
158
158
-40°F (-40°C)
75
100
130
130
85
98
120
158
* Lengths may vary. Please contact a ProLine representative for more information.
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 19
Self-Regulating Heat Cable Comparison
ProLine self-regulating heat cable features a more flexible outer jacket and more durable
carbon core than other leading brands of self-reg cable. These features provide more
consistent performance, longer lifespan, and easier installation in cold temperatures.
Key Features of ProLine Self-regulating Heat Cable vs. Other Cable Brands
Outer Jacket Quality
Typical self-regulating heat cable
The outer jacket of typical self-reg cable tends to “bubble” or separate from the cable core when the cable is
manipulated for turns. These irregularities create stress points on the cable that can result in water reaching the core,
leading to erratic heating and eventual cable failure.
Other Leading Brands of Self-regulating Cable
The outer jacket of most self-regulating heat cable
separates from the core at a typical bend radius of
2 inches.
ProLine Self-regulating Heat Cable
ProLine self-regulating heat cable features a higher
quality outer jacket that does not “bubble”. This reduces
the chances of water seepage and cable failure.
ProLine Radiant Self-regulating Heat Cable
ProLine self-regulating heat cable does not “bubble” at
an even tighter bend radius of 1½ inches.
Installation at Low Temperatures
Typical self-regulating heat cable
Typical self-regulating cable has a minimum installation
temperature of 32-40°F. This is because the carbon in
the cable becomes brittle and can easily break when
bent or manipulated at low temperatures.
The outer jacket also becomes stiff, making the securing
of cable to the pipes difficult during cold weather
installations. The outer jacket tends to “pucker” and pull
away from the core when making bends, compromising
the cable’s
integrity and
leading to
cable failure.
Therefore
installing most
self-regulating
heat cable at
temperatures
below 40°F
is not
recommended.
ProLine self-regulating heat cable and
plug with GFCI.
20 Toll Free: 866.676.9276
ProLine self-regulating heat cable
ProLine self-regulating cable features a higher quality
carbon center that is more resilient in low temperatures,
thereby allowing the cable to be safely installed at
temperatures as low as 0°F.
The higher quality outer jacket also remains flexible at
low temperatures, resulting in more reliable performance
and easier installation when securing to various pipe
trace applications.
“In all the years I’ve been installing radiant heating
systems, I’ve noticed that “bubbles” in the outer jacket
of the cable almost always result in a point of failure.
The superior outer jacket of ProLine’s self-reg cable
helps to eliminate this problem.”
www.prolineradiant.com
– Eric W., Licensed Contractor
[email protected]
PROLINE PIPE TRACE CABLE ORDERING INFORMATION
Pre-Terminated Self-Regulating Cable (Pipe, Roof and Gutter
Description
Length
Output @ 50°F
Voltage
PLSR-120-50
Pre-terminated Self-Regulating Heat Cable
50
6W/ft.
120
PLSRT-120-75
Pre-terminated Self-Regulating Heat Cable
75
6W/ft.
120
PLSRT-120-100
Pre-terminated Self-Regulating Heat Cable
100
6W/ft.
120
PLSRT-120-50 GF
Pre-terminated Self-Regulating Heat Cable
50
6W/ft.
120
PLSRT-120-75 GF
Pre-terminated Self-Regulating Heat Cable
75
6W/ft.
120
PLSRT-120-100 GF
Pre-terminated Self-Regulating Heat Cable
100
6W/ft.
120
Self-Regulating Cable (Pipe, Roof and Gutter)
PLSR-120-5
Self-Regulating Heat Cable
250’/500’/1000’
5W/ft.
120
PLSR-120-8
Self-Regulating Heat Cable
250’/500’/1000’
8W/ft.
120
PLSR-120-10
Self-Regulating Heat Cable
250’/500’/1000’
10W/ft.
120
PLSR-120-12
Self-Regulating Heat Cable
250’/500’/1000’
12W/ft.
120
PLSR-240-5
Self-Regulating Heat Cable
250’/500’/1000’
5W/ft.
208-277
PLSR-240-8
Self-Regulating Heat Cable
250’/500’/1000’
8W/ft.
208-277
PLSR-240-10
Self-Regulating Heat Cable
250’/500’/1000’
10W/ft.
208-277
PLSR-240-12
Self-Regulating Heat Cable
250’/500’/1000’
12W/ft.
208-277
*Cut fee
*Cut fee for non 250’/500’/1000’ rolls
250’/500’/1000’
PLSR Cable Accessories and Controls
Item Code
Description
PLSR00-Pipe
Power connection kit, includes end seal kit (PLSR12)
PLSR03-Aluminum
Aluminum application tape
PLSR03-Fiberglass
Fiberglass application tape
PLSR08
Plug-in cord set, 120 V GFCI, 125’ maximum run length
PLSR10
Splice / tee kit
PLSR12
End seal kit
WS-115
Air sensing NEMA 4 outdoor thermostat 120/240 V
WS-115R
Surface sensing NEMA 4 outdoor thermostat
Class I Div 2
PLSR-PTBO
Multiple entry octagon power connection kit with J-Box; hazardous locations, NEMA 4X
PLSR-PTBS
Power connection kit with J-Box; hazardous locations, NEMA 4X
PLSR-JHE
End seal kit; hazardous locations
PLSR-JHS
Inline splice tee kit; hazardous locations
PLSR-JHT
Tee splice; hazardous locations
PLSR12L
End seal kit with light (can be used at beginning or end)
PLSR-PP
Pipe trace power panel with GFEP (includes sensors)
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 21
Pipe Tracing
Item Code
Pipe Trace Cable Accessories and Controls
PLSR Cable Accessories and Controls
PLSR-PTBS - Power connection kit with J-Box;
hazardous locations, NEMA 4X
PLSR-PTBO - Multiple entry octagon power connection
kit with J-Box; hazardous locations, NEMA 4X
PLSR-JHE - End seal kit; hazardous locations
A Seal plate for main box
B Main end seal box
C Grommets
D Label
PLSR-JHS - Inline splice tee kit; hazardous locations
A Main box
D Gaskets for main box
B Pressure seal end E Cover for main box
C Grommets
F Label
PLSR-JHT - Tee splice; hazardous locations
A Main box
D Gaskets for main box
B Pressure seal end E Cover for main box
C Grommets
F Label
PLSR10 - Splice / tee kit
A Clamp tie
B Mastic strips (1½” long x 1” wide)
C Heat-shrinkable tube (8” long x 1” diameter)
D Heat-shrinkable tube (1” long x ⅛” diameter)
E Heat-shrinkable tube (1” long x ½” diameter)
F Uninsulated braid crimp
G Cable ties
H Insulated bus wire crimps
I Black cloth tape (6” long)
J Heat-shrinkable cap
K Heat-shrinkable tube for ground
JSR00 - Power connection kit - with end seal kit (PLSR12)
A Black-shrinkable tube (5½” long x ⅛” diameter)
F Gasket
G Lock nut
B Green-shrinkable tube (6” long x ¼” diameter)
C Seal fitting and white grommet
H Blue grommet
D Black-shrinkable tube (1” long x ½” diameter)
I Wire nuts
E Mounting bracket for piping
J Labels
22 Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 23
Self-regulating Roof Heating Cable
Maximum Cable Length in feet
at Cable Breaker Size
Most roof deicing applications are best served by using
ProLine’s self-regulating heat cable. The heat cable
Cable
Startup Temp.
can be installed in gutters and downspouts to keep
Breaker Size
15A
structures safe from ice damage and frost erosion.
20A
30A
40A
15A
20A
30A
40A
Features and Benefits
200
200
200
200
498
530
530
530
505
PLSR-5
The irradiated conductive core of the heat cable
increases its heat output as the ambient temperature
falls, and decreases its output when the temperature
rises.
PLSR-8
• Will not overheat or burnout when overlapped
• Superior quality outer jacket and carbon core
• Features advanced technology that results in
highly effective, energy efficient operation
PLSR-10
• Can be cut to length in the field
• Fully automated
• Maintenance free
• Protects roofs by preventing ice dams and ice
buildup
ProLine roof and gutter deicing systems are
compatible with the following standard materials:
Roof Materials:
Gutter/Downspout:
Shake / Shingle ●
Metal
● Rubber / Tar ●
Plastic
● Wood / Metal
●
Wood
●
Toll Free: 866.676.9276
240 V
32°F (0°C)
190
200
200
200
429
505
505
-4°F (-20°C)
165
200
200
200
337
433
480
480
-40°F (-40°C)
140
190
200
200
255
328
400
400
50°F (+10°C)
145
150
150
150
354
406
420
420
32°F (0°C)
125
150
150
150
291
360
360
360
-4°F (-20°C)
110
145
150
150
183
229
350
350
-40°F (-40°C)
95
130
150
150
164
206
275
320
50°F (+10°C)
100
130
130
130
242
295
315
360
32°F (0°C)
90
120
130
130
177
216
246
315
215
-4°F (-20°C)
80
110
130
130
131
164
215
-40°F (-40°C)
75
100
130
130
114
141
170
215
50°F (+10°C)
100
130
130
130
183
229
229
240
32°F (0°C)
90
120
130
130
124
160
180
210
-4°F (-20°C)
80
110
130
130
91
124
158
158
-40°F (-40°C)
75
100
130
130
85
98
120
158
* Lengths may vary. Please contact a ProLine
representative for more information.
Several roof heating options are available from ProLine
Radiant. From heating gutters and downspouts, roof
valleys, roof edges and trouble spots, and even heating
entire roofs, ProLine roof deicing experts can recommend
and design the ideal system for your specific needs.
Eliminate ice dams by heating roof edges.
24
PLSR-12
50°F (+10°C)
120 V
ProLine pre-terminated self-regulating heat cable with
and without a ground fault circuit interupter (GFCI).
www.prolineradiant.com
[email protected]
Self-Regulating Heat Cable System Overview
Roof Deicing
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 25
Self-Regulating Heat Cable Comparison
ProLine self-regulating heat cable features a more flexible outer jacket and more durable
carbon core than other leading brands of self-reg cable. These features provide more
consistent performance, longer lifespan, and easier installation in cold temperatures.
Key Features of ProLine Self-regulating Heat Cable vs. Other Cable Brands
Outer Jacket Quality
Typical self-regulating heat cable
The outer jacket of typical self-reg cable tends to “bubble” or separate from the cable core when the cable is
manipulated for turns. These irregularities create stress points on the cable that can result in water reaching the core,
leading to erratic heating and eventual cable failure.
Other Leading Brands of Self-regulating Cable
The outer jacket of most self-regulating heat cable
separates from the core at a typical bend radius of
2 inches.
ProLine Self-regulating Heat Cable
ProLine self-regulating heat cable features a higher
quality outer jacket that does not “bubble”. This reduces
the chances of water seepage and cable failure.
ProLine Radiant Self-regulating Heat Cable
ProLine self-regulating heat cable does not “bubble” at
an even tighter bend radius of 1½ inches.
Installation at Low Temperatures
Typical self-regulating heat cable
Typical self-regulating cable has a minimum installation
temperature of 32-40°F. This is because the carbon in
the cable becomes brittle and can easily break when
bent or manipulated at low temperatures.
The outer jacket also becomes stiff, making the securing
of cable to the roof, gutter, or pipes difficult during cold
weather installations. The outer jacket tends to “pucker”
and pull away from the core when making bends,
compromising
the cable’s
integrity and
leading to
cable failure.
Therefore
installing most
self-regulating
heat cable at
temperatures
below 40°F
is not
ProLine self-regulating heat cable and
recommended.
plug with GFCI.
26 Toll Free: 866.676.9276
ProLine self-regulating heat cable
ProLine self-regulating cable features a higher quality
carbon center that is more resilient in low temperatures,
thereby allowing the cable to be safely installed at
temperatures as low as 0°F.
The higher quality outer jacket also remains flexible at
low temperatures, resulting in more reliable performance
and easier installation when securing to roofs, gutters,
and pipes.
“In all the years I’ve been installing roof heating
systems, I’ve noticed that “bubbles” in the outer jacket
of the cable almost always result in a point of failure.
The superior outer jacket of ProLine’s self-reg cable
helps to eliminate this problem.”
www.prolineradiant.com
– Eric W., Roofing Contractor
[email protected]
Self-Regulating Heat Cable Specs
Technical Data
PLSR Cable Accessories and Controls
Item Number
Service voltage
110-120, 208-277 V
Maximum maintain or
continuous exposure
temperature (power
on)
149°F (65°C)
Maximum intermittent
exposure temperature
1,000 hours (power on
or off)
-40° to 185°F (-40° to 85°C)
Minimum installation
temperature
-40°F (-40°C)
Protective braid
resistance
< 18.2Ω/km
Bus wire gauge
16 AWG
Description
PLSR00-Roof
Power connection kit
PLSR03-Fiberglass
Fiberglass application tape
PLSR03-Aluminum
PLSR08
PLSR10
Aluminum application tape
Plug-in cord set, 120 V GFCI,
125 ft. maximum run length
Splice / tee kit
PLSR12
PLSR12L
PLSR14
PLSR-14IR
Approvals
UL listed; hazardous
PLSR15
Certifications
Class I, Div.2 Groups A,B,C,D
Class II, Div.2 Groups F,G
Class III
WS-115R
WS-115
End seal kit
End seal with light (can be
used at beginning or end)
Roof clips - 50/bag
Insulated roof clips - 50/bag
Downspout hanger kit
Air sensing NEMA 4 outdoor
thermostat 120/240 V
Surface sensing NEMA 4
outdoor thermostat
For additional information, please contact a ProLine
representative at 866.676.9276.
PROLINE ROOF HEATING CABLE ORDERING INFORMATION
Pre-Terminated Self-Regulating Cable (Pipe, Roof and Gutter
Item Code
Description
Length
Output @ 50°F
Voltage
PLSR-120-50
Pre-terminated Self-Regulating Heat Cable
50
6W/ft.
120
PLSRT-120-75
Pre-terminated Self-Regulating Heat Cable
75
6W/ft.
120
PLSRT-120-100
Pre-terminated Self-Regulating Heat Cable
100
6W/ft.
120
PLSRT-120-50 GF
Pre-terminated Self-Regulating Heat Cable
50
6W/ft.
120
PLSRT-120-75 GF
Pre-terminated Self-Regulating Heat Cable
75
6W/ft.
120
PLSRT-120-100 GF
Pre-terminated Self-Regulating Heat Cable
100
6W/ft.
120
5W/ft.
120
Self-Regulating Cable (Pipe, Roof and Gutter)
PLSR-120-5
Self-Regulating Heat Cable
250’/500’/1000’
PLSR-120-8
Self-Regulating Heat Cable
250’/500’/1000’
8W/ft.
120
PLSR-120-10
Self-Regulating Heat Cable
250’/500’/1000’
10W/ft.
120
PLSR-120-12
Self-Regulating Heat Cable
250’/500’/1000’
12W/ft.
120
PLSR-240-5
Self-Regulating Heat Cable
250’/500’/1000’
5W/ft.
208-277
PLSR-240-8
Self-Regulating Heat Cable
250’/500’/1000’
8W/ft.
208-277
PLSR-240-10
Self-Regulating Heat Cable
250’/500’/1000’
10W/ft.
208-277
PLSR-240-12
Self-Regulating Heat Cable
250’/500’/1000’
12W/ft.
208-277
*Cut fee
*Cut fee for non 250’/500’/1000’ rolls
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 27
Roof Deicing
For information about ProLine Radiant roof heating cable
accessories, refer to the Information on page 28.
Self-Regulating Roof Heating Cable
Pictured above is an example of gutter damage
caused by heavy ice buildup.
ProLine roof deicing systems can save you money in the long run be eliminating costly roof
repairs and water damage. ProLine’s self-regulating heat cable and low-voltage systems are easy
to customize and install.
PLSR RoofHeat Cable Accessories
PLSR14 - Roof clips
A Roof clips - 50 per bag
PLSR14IR - Roof clips
A Insulated roof clips -50 per bag
PLSR15 - Downspout hanger kit
A Hanger bracket
B Clamp ties
PLSR10 - Splice / tee kit
A Clamp tie
B Mastic strips (1½” long x 1” wide)
C Heat-shrinkable tube (8” long x 1” diameter)
D Heat-shrinkable tube (1” long x ⅛” diameter)
E Heat-shrinkable tube (1” long x ½” diameter)
F Uninsulated braid crimp
G Cable ties
H Insulated bus wire crimps
I Black cloth tape (6” long)
J Heat-shrinkable cap
K Heat-shrinkable tube for ground
JSR00 - Power connection kit - with end seal kit (PLSR12)
A Black cloth tapes (6” long x 1” width)
B Plug-in ground-fault equipment protection device
C Black heat-shrinkable tube (8” long x ¾” diameter) D Black heat-shrinkable tube (5” long x ¾” diameter) E Black heat-shrinkable tube (1” long x ⅛” diameter)
F Black heat-shrinkable tube (1½” long x ⅓” diameter)
G Black heat-shrinkable tube (1” long x ½” diameter)
H Uninsulated braid crimp
I Uninsulated bus wire crimps
J Mastic strips
K Clamp ties
L Warning labels
M Deicing/snowmelt equipment labels
28 Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Low-Voltage Roof Deicing Systems
ProLine’s Industry-Leading Roof Deicing System
ProLine low-voltage roof deicing systems feature a unique, self-regulating, semi-conductive
polymer heating element that is very thin and can be cut on site and discreetly nailed or stapled
under shingles for quick, easy installation. The heating element is fabricated with Mylar on both
sides for added protection from alkaline, UV or salt damage.
Roof Deicing
The advanced roof heating system protects the roof
from the harmful effects of ice dams that can lead to
water seeping into roof decking, and eventually into
the structure. The system is maintenance free and fully
automated. The roof heating system can be installed
under a variety of roofing materials, including shingles
and metal.
The low-voltage roof deicing system is one of the most
advanced and efficient roof deicing systems available,
and is available in 3, 6, 9 and 12-inch widths. The heating
elements can be cut and customized for just about any
roof heating application.
Installing a ProLine Radiant roof deicing system is
considerably easier than most other competitive roof
heating systems. The low-voltage heating element can
be nailed or attached with
fasteners or screws under a
variety of roofing materials,
including metal.
Features and Benefits
• Extremely Thin Profile – Allows for simple, discreet
installation under roofing.
• Can be Cut on Site – The flexible heating element
can be cut to size on site for a perfect fit.
• Versatile - ProLine Radiant’s low-voltage system can
be installed under most roofing materials, including
metal.
• Polymer Heating Element - Unlike many other roof
heating systems, the ProLine low-voltage heating
element can be nailed or stapled through, simplifying
the installation process.
• Self Regulating – When the ambient temperature
rises, the electrical resistance increases and the
consumption of electricity decreases, preventing
the element from overheating and ensuring energyefficient operation.
ProLine low-voltage roof heating element being installed.
Toll Free: 866.676.9276
• Protective Mylar Fabrication – Provides durability,
by protecting the heating element from alkaline, salt
and UV damage.
www.prolineradiant.com
[email protected] 29
Fully Automated Roof Deicing Solutions
How it Works
ProLine’s roof deicing systems
involve three main components:
a heating element, transformer,
and activation device (i.e., an
aerial-mount snow switch and/
or temperature sensor) to trigger
system operation when weather
conditions warrant.
The semi-conductive polymer
heating element is thin, flexible,
and can be cut on site.
The transformer is
responsible for a
specific section of the
deicing system, and
can step down from
high voltage to low
voltage (60V or less).
It is the source for monitoring the
power and output to the system
heating element to ensure safe,
accurate performance of the roof
deicing system.
When conditions warrant, the
activation device/snow sensor
triggers the control panel. The
controller then sends power to
the heating element to warm
roof.
Illustration: How ice dams form on roofs.
12637 South 265 West, Suite #100A
Draper, UT 84020 USA
Phone: 801.948.7600
Fax: 801.948.7599
Toll free: 866.676.9276
30 Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 31
ProLine’s electric radiant floor heating system is one of the most popular and durable floor
heating solutions on the market. Available pre-spaced in mats with an adhesive backing or on the
spool, the versatile heat cable is effective for virtually all types of floor surfaces, including tile,
marble, slate, laminates, and hardwood.
Features Include:
• Single-point connection
• Twin-conductor cable
• Safety approved for wet locations
• Flexible installation
• Durable construction
• 25-year warranty
ProLine - Radiant Floor Heating Mat
The ProLine floor warming system includes a heating cable that is
pre-spaced on an adhesive backed fiberglass mesh that allows
for quick, simple rollout installation.
ProLine - Radiant Floor Heating Cable
Available off the spool, the ProLine floor warming cable includes
heating cable with a 10-foot cold lead.
Floor Heating Cable Specifications
Cable construction
Twin conductor
Rated voltage
120 V, 240 V
Output (cables)
12W/ft.2 (130W/m2)±10% (at recommended spacing)
Output (mats)
12W/ft.2 (130W/m2)±10%
Recommended spacing
3-inches (76.2mm)
Bending radius
1-inch (25.4mm)
Cable diameter
1/8 to 1/6-inch (3.2mm-4.2mm)
Conductor insulation
Fluoropolymer
Outer insulation
High temperature PVC
Max. ambient temperature
104°F (40°C)
Min. installation temperature
40°F (5°C)
Cold lead
2-wire 16 AWG plus ground braid; 10 feet (3m) length
32 Toll Free: 866.676.9276
www.prolineradiant.com
All of the
ProLine floor
heating systems
offer you a
choice of
technologically
advanced
thermostats.
[email protected]
PROLINE FLOOR HEATING ORDERING INFORMATION
ProLine Mats
ProLine Cable
120 Volt Cable
120 Volt Mat
Item
Number
Heated
Area
(Sq. ft.)
Mat
Dimensions
(Feet)
Watts
(12 W/Sq. ft.)
Amps
Ohms
TM1020
20
1.5 x 13.3
240
2.0
60.0
TM1030
30
1.5 x 20.0
360
3.0
40.0
TM1040
40
1.5 x 26.7
480
4.0
30.0
240 Volt Mat
Item
Number
Heated
Area
(Sq. ft.)
Mat
Dimensions
(Feet)
Watts
(12 W/Sq. ft.)
Amps
Ohms
Approximate Heat Coverage
(Square feet)
Item
Number
Length
(Feet)
TC10140
38,9
6
10
TC10240
77.8
13
19
2-inch
spacing
Standard
3-inch
spacing
Watts
Amps
13
120
1.0
120
26
240
2.0
60.0
4-inch
spacing
Ohms
TC10360
116.7
19
29
39
360
3.0
40.0
TC10480
155.6
26
40
52
480
4.0
30.0
TC10600
194.5
32
49
65
600
5.0
24.0
TC10840
272.4
45
68
91
840
7.0
17.1
TC10960
311.3
52
78
104
960
8.0
15.0
TC11210
391.7
65
98
131
1210
10.1
11.9
Watts
Amps
Ohms
240 Volt Cable
Length
(Feet)
Standard
3-inch
spacing
TM2020
20
1.5 x 13.3
240
1.0
240.0
TM2040
40
1.5 x 26.7
480
2.0
120.0
TM2050
50
1.5 x 33.3
600
2.5
96.0
TC20360
116.7
19
29
39
360
1.5
160
TM2100
100
1.5 x 66.7
1200
5.0
48.0
TC20600
194.5
32
49
65
600
2.5
96.0
TM2120
120
1.5 x 80.0
1440
6.0
40.0
WARRANTY INFORMATION
ProLine Floor Heat Cable: 25-year limited warranty.
Toll Free: 866.676.9276
2-inch
spacing
4-inch
spacing
TC20840
272.4
45
68
91
840
3.5
68.6
TC21080
350.2
58
88
117
1080
4.5
53.3
TC21440
466.9
78
117
156
1440
6.0
40.0
TC21790
580.1
97
145
193
1790
7.5
32.2
TC22090
678.4
113
170
226
2090
8.7
27.6
TC22630
851.8
142
213
284
2630
11.0
21.9
TC22840
922.2
154
231
307
2840
11.8
20.3
www.prolineradiant.com
[email protected] 33
Floor Heating
Item
Number
Approximate Heat Coverage
(Square feet)
Floor Heating Cable for Concrete Slab
Slab/Storage floor heating cable is designed for installation in new concrete slab applications.
The heat cable is tied directly to the re-mesh and embedded at least ½-inch below the surface.
The thermal heating cable efficiently uses the concrete slab to store and distribute heat
evenly throughout its intended area. The ProLine heat cable is affordable and can be installed
commercially or in residences to provide radiant heating for virtually any type of flooring,
including decorative concrete, hardwood, carpet, laminate and ceramic tile to provide luxurious
warmth to any home or business.
Floor Heating Applications
Designed to produce 10-15 watts per square foot, ProLine
Slab/Storage heating cable is the premier floor heating
solution for in-slab applications and decorative concrete
of both custom residential and large commercial projects.
The radiant floor heating system can efficiently provide
comfortable heat for virtually any type of radiant floor
heating application, ranging from decorative concrete to
hardwood, carpet and ceramic tile.
The Slab/Storage radiant floor heating system offers
maintenance-free operation, is easy to install and
features a comprehensive 10-year manufacturer
warranty. Because the Slab/Storage heat cable is
waterproof, it is safe for use in both wet and dry
applications, including tiled shower and bathroom floors.
Features and Benefits
• Single-point connection simplifies installation
• Safe for use in wet and dry applications
• For commercial and residential
• Save money by heating during “off-peak” hours
• Durable construction
• Flexible and easy to install
• Can be installed in concrete slab under virtually all
floor types. (Ideal for heating decorative concrete.)
• 10-year manufacturer warranty
Decorative Concrete
Slab/Storage heat cable has proven to be perfectly
suited for heating decorative concrete floors. Designed
to withstand the stress of heavy concrete pours, ProLine
Slab/Storage heat cable is ideal for safely heating
decorative and stained concrete floors without affecting
the luster of colors over time. The reliability of the
slab heating system has made it a favorite among
professionals specializing in concrete floor installations.
Slab/Storage Heat features rapid response times and
utilizes the concrete slab to store and distribute heat,
maximizing the efficiency of the system.
Versatile and Easy to Install
The Slab/Storage floor heating system is easy to
customize and install in any size or shape of room. While
it can be installed under any type of floor, the cable is
required to be embedded in at least ½-inch of concrete
or mortar.
34 Toll Free: 866.676.9276
Slab/Storage heating
cable is durable,
versatile, and easy
to install. ProLine
Slab/Storage heat’s
proven track record
is one reason why
it’s a favorite among
professional builders.
www.prolineradiant.com
[email protected]
ProLine Radiant FoilHeat Floor Warming System
ProLine Radiant’s FoilHeat cut-and-turn floor heating mat is a unique electric radiant floor heating
system that is designed for use under carpet, laminate, engineered wood and other floating
floors. The FoilHeat mats can be cut and shaped on site to meet the specific requirements of
the project. The efficient floor heating system is ideal for heating any size or shape room, from
basements and bedrooms to commercial offices, and more.
Heated Carpet and Laminate Flooring
FoilHeat is an ultra thin electric radiant floor heating
system primarily for use under carpet, laminate,
engineered wood and other floating floors. The principle
advantages of using FoilHeat include ease of installation,
rapid response time, and uniform heating of floor
surfaces. The special materials used makes it free from
problems of ‘hot-spots’ or localized heating.
Specifcations
Features and Benefits
• Simple “roll out” installation
• Installs between the insulation pad and the floor
• There is virtually no floor buildup because of the
grounded, flat aluminum
• No thin-set is required
• The aluminum construction efficiently distributes heat
quickly and evenly
Power
Available in 120 V and 240 V
Output rating
12 W/ft.
Thickness
⅛ inch (3 mm)
• Watertight (Heated carpet floors can be steam
cleaned.)
Cable spacing
2 inches (50 mm)
• UL approved
Cold lead
10 feet (3.0 meters)
• 12 watts per square foot (41 BTUs per square foot)
Connections
2 conductor with ground
• 5-year manufacturer warranty
Inner insulation
Advanced flouropolymers
• NOTE: Any overlay must not exceed an R-value of 1.0
2
• System is completely grounded and safe
Some advantages of
using FoilHeat include
the ease of installation
and uniform floor
heating. The special
materials used help to
eliminate problems of
‘hot-spots’ or localized
heating.
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 35
Floor Heating
ProLine’s FoilHeat
electric radiant floor
warming system
shown being installed
to heat basement
floor.
Heating Element Construction
from one corner. The power lead is a thin flat two-core
flexible cord, consisting of two insulated conductors with
a metal sheath and an outer sheath. Depending on your
heating requirement, FoilHeat is available in 120 and
240 volts at 12 watts per square foot. It is available in
predetermined lengths with cold tail – prefabricated and
tested in a carefully controlled factory environment.
The heating element of the FoilHeat system is made
with fluoropolymer insulated heating cables that are
sandwiched between two layers of specially reinforced
aluminum foil. The uniform spacing of the heating
elements, further backed by the aluminum foil, ensures
even heat distribution. The heating element is connected
to a power-supply cable, which exits the laminate mat
NOTE: Only cut the foil. DO NOT cut the
actual heating cable.
Only cut the foil, not
the heating cable.
When cutting the mat, be sure to cut the mat only. DO
NOT cut or damage the heat cable.
FoilHeat mats can be easily cut on site.
120 V FoilHeat Mats Sizing Guide (12 watts per square foot)
Heated Area (Sq. ft.)
Part Number
Length (Feet)
Wattage (W)
Amps (A)
10
LM1010
6
120
1.0
25
LM1025
15
300
2.5
50
LM1050
30
600
5.0
70
LM1070
42
840
7.0
240 V FoilHeat Mats Sizing Guide (12 watts per square foot)
Heated Area (Sq. ft.)
36
Part Number
Length (Feet)
Wattage (W)
Amps (A)
25
LM2025
15
300
1.25
50
LM2050
30
600
2.50
95
LM2095
57
1140
4.75
140
LM2140
84
1680
7.00
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Interior Radiant Heat Controls
The ProLine Radiant electronic thermostats are specifically designed to control electric radiant
floor heating systems for maximum comfort and minimum power consumption. Developed for
the modern home, the programmable thermostat features a large back-lit display and simple
user interface. The system temperature is controlled by an external or built-in floor sensor.
Each thermostat includes an integrated Ground Fault
Circuit Interrupter (GFCI, Class A). The thermostat
is an electronic on/off thermostat for controlling
temperature by means of a sensor placed externally.
The heat output is switched on and off with a
difference of only 0.7° F (0.4°C).
General Thermostat Specifications
On/Off control, easy-to-read digital
display, 7-day programmable
Supply voltage
120/240 V ±15%, 50/60 Hz
Load
15A maximum (resistive load)
The thermostat can be configured for control of
the floor temperature and regulator without a
sensor. The advanced thermostat is compatible with
existing floor sensors by means of a temperature
setting, making it the best thermostat for renovation
purposes.
Power
1.800 W at 120 VAC / 3.600 W at 240 VAC
Temperature control range
40 to 104°F (5 to 40°C)
Ambient temperature range
32 to 104°F (0 to 40°C)
Floor temperature sensor
2-wire, 10-foot lead wire
Floor sensor type
NTC (12 KΩ) 10 ft (3 meters)
Designed for ease of use and superior performance,
the thermostat and GFCI are dual voltage models
suitable for 120/240V, 50/60 Hz power supplies.
GFCI
Class A (5 mA trip level)
On/Off differential
0.7°F (0.4°C)
Regulation principle
PWM / PI
Housing
NEMA 2 (IP21)
Dimensions (H/W/D)
4.8, 3.0, 1.0 inch (123, 75, 25mm)
For more information about thermostats for radiant
floor heating systems or ProLine heat cable and floor
warming systems, contact a ProLine radiant heat
expert at 866.676.9276 or email us at:
[email protected]
General Thermostat Features
Adjustable Temperature Offset
Simple user interface and thoughtful installation design
The set point can be adjusted to match the actual floor
temperature. This ensures a 100 percent
accurate measurement and control of
your underfloor heating system.
Screw terminals for safe and easy installation
Adjustable Temperature Scale
Easy to use (Can be operated without the use of the manual)
Pre-programmed for quick setup installation
The floor temperature scale can be
adjusted within the temperature
range of +41°+104°F.
Dual voltage (120 V and 240 V)
Temperature Limitation
GFCI 5mA protection built in
The thermostat also
features a maximum
temperature function to
protect wood floors and
minimum temperature
functions for comfort.
Large back-lit display for easy viewing
Fully Programmable
Class A GFCI: Suitable for wet room installation
Four-event, seven-day energy savings
Monitored energy consumption
2-year manufacturer warranty
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 37
Floor Heating
Functions
ProLine Floor Heating Thermostats
PRO Floor Sensing Programmable Thermostat
An “all-in-one” programmable thermostat for electric underfloor heating control where optimal comfort
temperature and minimum energy consumption is required. Includes floor sensor with
10-foot (3-meter) cable.
• Simple user interface and thoughtful installation design
• Pre-programmed for quick setup
• Monitored energy consumption
• Easy to use / Simple operation
• Multi voltage: 120-240 VAC (includes 208 VAC)
• Output relay: 15A
• Large back-lit display for easy reading
• Class A GFCI for wet room installation
PRO Dual Sensing Programmable Thermostat
The programmable thermostat with dual sensors is an “all-in-one” programmable thermostat for electric
underfloor heating control where optimal comfort temperature and minimum energy
consumption is required.
• Simple user interface and thoughtful installation design
• Includes two sensors: a built-in air sensor (to measure room temperature) and a
floor sensor with 10-foot (3-meter) cable to measure actual floor temperature.
• Pre-programmed for quick setup
• Monitored energy consumption
• Simple operation (Easy to use)
• Multi voltage: 120-240 VAC (includes 208 VAC)
• Output relay: 15A
• Large back-lit display for easy reading
• Serves as single thermostat for all applications
(room, floor, room with floor limitation and as regulator)
• Class A GFCI for wet room installation
PRO Power Module Slave Relay
For large floor heating applications, the Power Module Slave Relay can be extended
with additional Power Relay Modules. The PRO Slave Relay module features a built-in
Class A GFCI and increases output by 15 amps per module. Output can thus be
increased by 15A per module.
•
•
•
•
•
•
Easy to use
Screw terminals for safe and easy installation
For use only with the CT Programmable Thermostat
Multi voltage: 120-240 VAC (includes 208 VAC)
Output relay: 15A
Class A GFCI: suitable for wet room installation
PRO Digital/Non-programmable Thermostat with Floor Sensor
Optimal comfort in controlling electrical underfloor heating. Built on effciency, intuitive
operation and with a stylish design. Includes floor sensor with 10-foot (3-meter) cable.
•
•
•
•
•
•
38
Simple user interface and thoughtful installation design / Easy to use
Screw terminals for safe and easy installation
Multi voltage: 120-240 VAC (includes 208 VAC)
Output relay: 15A
Large back-lit display for easy reading
Class A GFCI: suitable for wet room installation
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 39
Hydronic Radiant Floor
Heating and Snow
Melting Solutions
ProLine Offers Unmatched Service, Product Selection and Support
ProLine Radiant is a nationally recognized authority in the design and installation of hydronic
radiant heating and solar hot-water systems. The products and services that ProLine offers
are based on extensive training and years of field experience. ProLine is customer focused,
consultative and unbiased in its product offerings, mechanical engineering services and
installation approach. By utilizing ProLine’s dedication and expertise, you can be confident in a
complete and seamless radiant heat solution.
Preeminent Consulting and Analysis
ProLine provides free, no obligation consulting services
by experienced professionals to ensure that you’ll receive
a thorough, upfront analysis of your project. We evaluate
every aspect of the system to offer the best, complete
solution to meet your specific needs.
The Radiant Heat Information Authority
By complementing its wide selection of superior radiant
heat products with unmatched customer service and
engineering expertise, ProLine Radiant has proven itself
as the unbiased radiant heat authority, and trusted
leader of radiant heat solutions.
Wide Selection of Proven Products
Unlike many radiant heat manufacturers and distributors
that carry only one brand or limited product lines, ProLine
offers a wide selection of the industry’s most reputable
solutions – all at competitive pricing.
ProLine makes the process of finding, purchasing and
installing radiant heat systems easy for construction professionals. ProLine works directly with installers to make
these systems a reality. For more information, visit us
online at www.prolineradiant.com.
ProLine hydronic system components are at the top
of their class, so you can be assured that your radiant
heat system consists of the most trusted components.
From boilers and manifolds to pumps and controls, your
system will consist of the very best in each category.
Complete Design and Engineering Services
You will receive a comprehensive set of engineering
drawings that accurately describe each component
of the system and give you a visual perspective on
every key process, such as:
•
•
•
•
ProLine Radiant
hydronic snow
melting system’s
mechanical / boiler
room (left) and
photo of system
installed under
pavers (below).
Tubing installation (spacing, sizing, lengths)
Manifold Placement
Under Slab Insulation
Distribution Line Installation (size, lengths)
Mechanical Equipment
• Boiler Systems
• Pump Boards
• Pipe Configurations
• Controls
Unmatched Installation Support
In addition to access to mechanical engineers and
electricians, you can request an experienced radiant
heat installer to come to your location and supervise
the installation. Or, for a complete turnkey solution, you
may request for ProLine to provide an entire hydronic
installation crew.
40
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
ProLine Leads the Way
The professionals at ProLine Radiant are among the most knowledgeable and customer
service oriented experts in the business. Our commitment to service, which includes
unparalleled design, training, and installation support, is just one reason why building
professionals repeatedly choose ProLine for all their radiant heat projects.
“By working with ProLine, I feel like I have
the best radiant heat partner working with
me, so I never feel alone during the installation process. The designer, engineer and
electrician are always there for me if I have
any questions or needs. Their expertise ensures that the installation goes smoothly and
the customer is satisfied.”
David V. - Landscape
Summary of Benefits
Industry-leading Consulting Services
Wide Selection of Proven Products
Complete System Design and Engineering
Unmatched Installation Support
(Including the option of onsite assistance)
Comprehensive Information Resource
ProLine is committed to providing the best customer
service in the business. You can be confident that the
system design and components are among the very
best in the industry. We have worked hard to earn our
reputation as a trusted leader and we take pride in the
national awards we have received:
First Place System Showcase (16+ zones*)
– Radiant Panel Association
Second Place System Showcase (Simplicity)
– Radiant Panel Association
Design for a hydronic floor heating system.
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected] 41
Hydronic Heat
From our wide selection of proven products to unmatched
design, engineering and support services, ProLine is the
premier radiant heat solutions provider. We’re confident
that if you compare prices, product quality and customer
service, you’ll choose ProLine.
Your Complete Radiant Heat Solutions Provider
Residential, Commercial and Industrial Radiant Heat Applications
Residential Snow Melting
Commercial Snow Melting
Radiant Heated Floors
Radiant Heat for all Types of Floor Surfaces
Retrofit Systems for Heating Existing Floors
Hydronic and Electric Floor Heating Solutions
Self-regulating Systems
Roof Heating Solutions
Heated Driveways
Porches and Steps
Ramps and Entry Ways
Sidewalks, Patios and Custom Walkways
Parking Areas
Portable Snowmelt Solutions
Custom Snow Melting Solutions
Included Services and Capabilities
Free Professional Consulting (866.676.9276)
Complete System Design and Engineering
Industry-leading Customer Service
Post-sales Technical Support
Most Advanced, Proven Products
Technical / Installation Support
Free Product and Installation Training
Free Quotes
Critical, High-traffic Areas
Ramps and Loading Docks
Outdoor Shopping Malls
Sidewalks and Parking Areas
Federal Government Facilities
State Transit Authorities / Platforms
Helicoptor Pads
Custom Snowmelt Applications
Hydronic and Electric Snowmelt Systems
Complete Roof Deicing Systems
Gutter Melt and Downspout Heating
Roof Edge (Panel) Heating
Most advanced Low-voltage Roof Heating
ProLine Radiant specializes in providing custom
radiant heat systems to match the specific
demands of your project. If you have any type of
heating need, contact ProLine today and let us
help.
ProLine Radiant accepts no responsibility for possible errors in catalogs, brochures, other printed materials, and website information.
ProLine reserves the right to alter its products without notice. This also applies to products already on order provided that such alteration
can be made without subsequent changes being necessary in specifications already agreed upon. All trademarks in this material are the
property of the respective companies. © 2015 All rights reserved.
12637 South 265 West, Suite #100A
Draper, UT 84020 USA
Phone: 801.948.7600
Fax: 801.948.7599
Toll free: 866.676.9276
Toll Free: 866.676.9276
www.prolineradiant.com
[email protected]
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement