Crestron CAEN 7X2, 7X1, 4X2, 4X1, 2X1, CLX -1DELV4, CLX-1DIM4, CLX-1DIM8, CLX-2DIM2, CLX-2DIM8, CLX-1FAN4, TPMC, TILT various, C2N-DB, CNX various, ILUX various, Cresnet various, PAC2, PAC2M, GLS -ODT, GLS-OIR, GLS-LOL, GLS-LCL Design Guide
Below you will find brief information for CAEN 7X2, CAEN 7X1, CLX CLX-1DIM8, PAC2 PAC2, ILUX various. This guide details Crestron's residential lighting solutions, covering system design types (wired, wireless, hybrid), module specifications (CLX series dimmers, fan controls), and control interfaces (touchpanels, keypads). It helps you design and order a complete system, including enclosures, wiring, and processors.
Advertisement
Advertisement
Crestron Green Light
®
Residential Lighting Design Guide
© 2009
Crestron Electronics Inc.
15 Volvo Drive
Rockleigh, NJ 07647
800.237.2041 www.crestron.com
For Commercial Lighting Solutions, refer to Doc. 4775
All brand names, product names, and trademarks are the sole property of their respective owners.
Crestron Residential Lighting Design Guide
Contents
I
NTRODUCTION
.................................................... 1
T HE S INGLE S OLUTION C ONTROL S YSTEM – A C RESTRON
E XCLUSIVE ............................................................ 1
C RESTRON C ONTROL T ECHNOLOGY ............................ 2
C
RESTRON
G
REEN
L
IGHT
TM ...................................... 2
S
YSTEM
D
ESIGN
................................................. 3
L IGHTING S YSTEM D ESIGN T YPES .............................. 4
S PECIFYING A L IGHTING S YSTEM ................................ 8
R EQUIRED L OAD S CHEDULE I TEMS .................................. 8
E XAMPLE L OAD S CHEDULE WITH P ANEL T ERMINATIONS ....... 9
R ESIDENTIAL L IGHTING W IRING P LAN ............................ 10
E QUIPMENT L IST S PECIFICATION ................................... 10
O RDERING A C RESTRON R ESIDENTIAL L IGHTING S YSTEM .... 10
G
REEN
L
IGHT
O
PTIONS
....................................... 11
CAENS
ERIES
E
NCLOSURES
.................................. 11
CAEN I NSTALLATION ................................................. 13
CAEN E NCLOSURE F RAMING ....................................... 13
CAEN W IRING ......................................................... 14
U NIVERSAL M OUNTING P LATES .................................... 15
C OVER E XTENSION K ITS ............................................. 16
CLX L
IGHTING
C
ONTROL
M
ODULES
.............................. 17
T
ERMINAL
B
LOCKS AND
M
ODULES
................................ 19
C
RESNET
® T
ERMINAL
B
LOCK FOR
CAEN A
UTOMATION
E
NCLOSURES
........................................................... 21
C
RESTRON
DIN R
AIL
P
RODUCTS
.......................... 23
DIN-AP2 ............................................................... 25
DIN-1DIMU4 ......................................................... 26
DIN-8SW8 ............................................................ 27
DIN-4DIMFLV4...................................................... 27
DIN-2MC2 ............................................................ 27
DIN-AO8 ............................................................... 28
DIN-IO8 ................................................................ 28
DIN-BLOCK ........................................................... 29
DIN-PWS50 .......................................................... 29
DIN-HUB ............................................................... 30
I NTERFACE E QUIPMENT ...................................... 31
W ALL M OUNT T OUCHPANELS .................................. 32
T ILT T OUCHPANELS ............................................... 34
TPMC S ERIES I SYS I /O W I F I T OUCHPANELS .............. 35
W IRELESS T OUCHPANELS AND H ANDHELDS ............... 36
K
EYPADS
......................................................... 37
C2N-DB S ERIES D ECORATOR K EYPADS .................... 37
CNX D
ESIGNER
S
ERIES
K
EYPADS
............................. 38
C AMEO ™ ........................................................... 39
I
L
UX
I
NTEGRATED
L
IGHTING
C
ONTROL
S
YSTEM
....... 41
I L UX F EATURES ........................................................ 42
W IRELESS I L UX R EMOTE ............................................ 42
M ULTI -U NIT E XPANSION ............................................. 43
C ONTROL S YSTEM I NTEGRATION .................................. 44
I L UX E XPANSION M ODULES ......................................... 45
W
ALL
B
OX
D
IMMERS AND
S
WITCHES
.................... 47
C RESNET W ALL B OX D IMMERS .................................... 48
C RESNET W ALL B OX S WITCHES ................................... 49
INFI NET™ W IRELESS T ECHNOLOGY ..................... 50
C
ONTROL
P
ROCESSORS
...................................... 53
PAC2 L IGHTING C ONTROL P ROCESSOR ..................... 53
PAC2M P ROFESSIONAL A UTOMATION M INI C ONTROL
S YSTEM .............................................................. 55
O
CCUPANCY AND
P
HOTOCELL
S
ENSORS
................. 58
GLS-ODT & GLS-OIR .......................................... 58
GLS-LOL & GLS-LCL .......................................... 58
I
NTEGRATED
S
HADE AND
D
RAPE
C
ONTROLLERS
...... 59
C2N-SDC .............................................................. 59
C2N-SDC-DC ........................................................ 59
C2N-SSC-2 .......................................................... 59
I
NTEGRATED
P
ARTNER
M
ODULES
.......................... 60
A
PPENDIX
A: E
XAMPLE
R
ESIDENTIAL
L
IGHTING
S
YSTEM
........................................................... 61
A
PPENDIX
B: T
OUCHPANEL
C
OMPARISON
C
HARTS
... 67
T ILT T OUCHPANELS ............................................... 67
W ALL M OUNT T OUCHPANELS .................................. 68
W IRELESS T OUCHPANELS & H ANDHELD R EMOTES ....... 69
A PPENDIX C: G ENERAL L IGHTING D ESIGN
C
ONSIDERATIONS
.............................................. 70
A PPENDIX D: G LOSSARY OF L IGHTING T ERMINOLOGY 73
Design Introduction
Introduction
Crestron is the world's leading manufacturer of advanced control technologies. Our developments in combining touchpanel technology with lighting control applications were the very first of their kind.
Only Crestron brings the most comprehensive line of userinterfaces to lighting and dimming control, plus the ability to remotely monitor, manage and control over standard IP networks.
Cresnet ® low-voltage wiring and/or RF control can be used throughout a wide range of system design possibilities, including traditional wiring with local intelligence or distributed, high-voltage wiring with centralized and/or distributed intelligence systems.
The wide range of Crestron multi-function user interfaces replaces large banks of traditional switches, dimmers, and timers. In addition to lighting, these user interfaces can also control security, HVAC, and audio/video systems. Only
Crestron provides a single control wiring bus to all of its components, simplifying installation and connection.
Each unique lighting control system reflects the needs and desires of the inhabitants. Designing and constructing a lighting and automation system to fill the requirements of your client is a challenging task, and Crestron offers the equipment and flexibility of design required for every one-of-a-kind solution.
Crestron interfaces provide manual and automatic controls; turning on exterior lights based on an astronomical clock, providing a single button press to turn all lights on, illuminating safe exits in case of emergency, and many other lighting possibilities.
Crestron products allow the designer to continually expand and change any lighting system. Crestron infiNET TM wireless devices provide a simple retrofit solution to expand a existing systems. There is no limit to the number or types of devices, the system can grow as needed to accommodate any last minute changes or new additions.
Crestron streamlines and simplifies all home technology by offering the ultimate in comfort and convenience. Whether from an easy-to-use color touchpanel, remote or customized keypad, Crestron eliminates the need to walk from room to room to adjust drapes, lights, temperature, and audio/video components- total control is always at your fingertips.
Every Crestron lighting system is completely modular and scalable, allowing virtually unlimited configuration and expansion flexibility.
The Single Solution
Control System – a Crestron Exclusive
Crestron connects people with technology. As products and systems become more complex, our solutions streamline and simplify technology so people can enjoy its benefits.
We understand that our touchpanels, keypads, and handhelds are how people interact with and experience the systems in their homes, offices, schools and churches. We allow individuals to create a comfortable environment, set a mood, and enjoy technology.
With our wide range of interface products, slim profile wall mount keypads and decorative faceplates, our products enhance a décor, complement a lifestyle, or personalize a room. Crestron offers the most brilliant graphics and intuitive, customized interfaces. We integrate more of the technology that people want and use everyday into our touchpanels; and provide ergonomically designed and easy-to-use wireless controllers, and flush-mount touchpanels of every size.
Tying all this technology together seamlessly is our exclusive Cresnet
®
cable, connecting the user to a powerful and flexible control system.
Doc. 5999F 1
Introduction Crestron Residential Lighting Design Guide
Crestron Control
Technology
View precise lighting levels, temperature and shade positions in any room throughout the home, graphically and quantitatively, from any touchpanel or PC.
Monitor and track current and historical device usage and intelligently manage resources.
Ethernet connectivity enables LAN or web-based system control and management, and sends email advisories about pre-determined events such as devices going off-line or automatic load shedding.
Crestron control processors provide the total integration of
Crestron devices, non-Crestron devices, and subsystems in any environment, for any purpose, anywhere. Crestron control processors can connect to any digital, serial, or analog system, and control by RF, IR, or hardwiring, making them the most flexible, powerful control systems ever devised.
Underlying the hardware are powerful, graphical programming tools, specifically designed to establish total control over any technology and make the user experience uncomplicated, intuitive, and easy to use.
Crestron also provides true feedback for essential control monitoring, function response to controls, and user inputs.
Crestron offers design solutions for every situation.
Selecting the proper equipment often depends on the kind of installation. New construction, major renovation, or minor renovation each present different design challenges.
Crestron Green Light
TM
Crestron Green Light is a complete line of lighting, HVAC, and shade/drape control for both commercial and residential applications, designed to maximize energy conservation and cost savings.
Crestron Green Light solutions underscore the company's ongoing commitment to environmental safety and energy conservation. Only Crestron offers a fully integrated global systems approach with the unique ability to monitor and manage all environmental and AV systems on a single platform that maximizes efficiencies and cost savings.
Crestron Green Light technology delivers total environmental control throughout a home or commercial facility to conserve energy and lower costs without sacrificing comfort and convenience. Crestron systems provide users the flexibility of both precise manual control of all systems and devices, and customized levels of automation to achieve advanced features such as daylight harvesting and load shedding. Only Crestron can schedule, monitor and manage all technology centrally and globally from touchpanels and PCs.
Crestron Green Light products meet ASHRAE standards and are fully CEC Title 24 compliant. Crestron is a member of the U.S.
Green Building Council (USGBC), the organization responsible for creating the LEED Green Building Rating System™. Crestron
Green Light solutions take a whole-building approach to sustainability, and facilitate the efficient operation of high performance green buildings. Additionally, all Crestron Green
Light products conform to the European Union (EU) Directive
202/95/EC Restriction of Hazardous Substances (RoHS).
For more information on Crestron Green Light, please visit
Crestron.com/gogreen
Doc. 5999F 2
Crestron Residential Lighting Design Guide System Design
System Design
The applied lighting control strategy determines the basic methods used to control the environment. When formulating an overall strategy, there are some basic considerations:.
New construction and major renovations provide the opportunity to easily run control cables from user interfaces to the control processor when the walls are open.
Existing construction or minor renovations often make the task of running cables more difficult, time consuming, expensive, or even impossible (in historic landmarks, etc.). In this case, you may choose to install a partialyl or completely wireless system
Light level control is achieved through dimming controls and daylight management, where applicable, to adjust the lighting to the appropriate level for different occupant activities
Occupancy sensing is used to switch the lighting on and off, independent of time intervals or scheduled periods. This allows the space to be responsive to individual use, and conserves energy
Scheduled lighting is determined by time of day, day of week, vacation, outdoor lighting, and safety lighting requirements. An astronomical clock (programmed with sunrise and sunset information) is often used to provide natural lighting transitions
HVAC control should be part of the overall control strategy, permitting additional economic and convenience benefits
Doc. 5999F 3
Crestron Residential Lighting Design Guide System Design
Lighting System Design Types
There are many ways in which a Crestron lighting control system can be organized. Construction type, client requirements, architectural restrictions, and many other factors determine the best solution. In general, retaining
Crestron control design flexibility produces the most reliable results.
Wireless Systems
The groundbreaking Crestron infiNET wireless technology provides reliable 2-way communications throughout a home or commercial structure without the need for physical control wiring. Crestron infiNET products offer a unique solution for retrofit projects. By replacing existing controls with infiNET switches and dimmers, provisions for automatic shutoff and overall control can be implemented with minimal changes to the existing wiring.
Employing a 2.4 GHz mesh network topology, every infiNET device functions as an RF repeater, increasing effective range and reinforcing the complete network by providing multiple redundant signal paths within the mesh network. Adding more infiNET devices or repeaters to the network effectively increases the range, strength, and reliability of the network.
Advantages of RF wireless control start with reduced capital and operating expenses. Wireless control can save as much as 30 to 40 percent on installation and material costs compared to a wired control system, making this option attractive for retrofit as well as new construction.
Installation costs are reduced because RF devices can be replaced one to one without involving control wiring.
Doc. 5999F
Crestron infiNET Wireless System
4
Crestron Residential Lighting Design Guide
Centralized Wired Systems
A centralized system is one in which all the high-voltage circuits are terminated within a Crestron automation enclosure and operate under a central control system. In a centralized design, the high voltage lighting, fans, motors and switch circuits are individually wired directly to the control modules in the Crestron automation enclosure.
The modules are controlled by low voltage or RF user interfaces in the living area. This greatly simplifies the high voltage wiring while creating a flexible and efficient design using keypad and touchpanel interfaces.
System Design
A central processor, connected via a local area network to the lighting modules and the user interfaces, is dedicated to lighting, fans, motors, HVAC, and security. Processors that are dedicated to other control systems can communicate via Ethernet, RS-232 or RS-422 to the central controller. This eliminates the need for additional control that separate safety and environmental systems and is a flexible, fully integrated design solution.
A Centralized Wiring System
Doc. 5999F 5
System Design
Decentralized Wired Systems
A decentralized system is the traditional wiring system of individual lighting circuits with local control. In the traditional distributed design wiring method, Crestron wall box dimmers can be retrofitted into a project after routine high voltage wiring is completed.
Crestron Residential Lighting Design Guide
In addition to the traditional high voltage wiring, a low voltage communication wire can be run from the dimmer to the nearest Cresnet® connection (or an RF wireless control can be used). This design offers the end user the familiarity of a traditional control coupled with the power and flexibility of automation. In a distributed design, the user has the ability to operate the lighting in the event of a temporary control system interruption.
A Decentralized Wiring System
Doc. 5999F 6
Crestron Residential Lighting Design Guide
Hybrid Systems
The most efficient and attractive lighting system designs are a hybrid of centralized processing and distributed dimmers. This provides the reliability of local control along with sophisticated centralized control, and limits the amount of wall clutter
A complete Crestron design is a blend of wireless and wired, distributed and centralized design in which central control intelligence and distributed local dimmers form a reliable whole house lighting control solution.
System Design
Large rooms, stairways, and frequently used rooms are often remotely controlled using the astronomical time clock or whole house presets. This level of control requires connection to a central dimming controller. Each room is equipped with a low voltage or wireless keypad for lighting preset selection and/or audio/video integration.
All of the dimmers in the system (grouped into the central controller for wiring convenience) communicate with each other through the Crestron control system, providing a complete, integrated solution
A Hybrid Wiring System
Doc. 5999F 7
Crestron Residential Lighting Design Guide
Specifying a Lighting
System
The Load Schedule
A lighting system design begins with a collection of complete information. This includes a detailed floor plan identifying all of the required elements. The first element of design, the load schedule, is developed from the floor plan. The load schedule lists the information on each electrical load connected to every circuit in an electrical panel. This primary source of information determines all of the overall requirements:
Lighting types, required voltage and current, dimmed or switched, fluorescent ballast types, circuit number, normal or emergency, and locations
The location and types of user interfaces used
(i.e., dimmers, switches, keypads, iLux™, infiNET™, and touchpanels)
The control processor details (larger systems should use a dedicated lighting control processor)
The window treatment details, which include shade/blind motors and relay control (consult the window treatment manufacturer for control details).
Required Load Schedule Items
1. Control zone: Controlled circuits that do not need to be physically wired together, but always operate in tandem. For example, perimeter lights, sconce lights and overhead lights all operating together
2. Location of controlled lighting zone, relevant to building site/drawings, floor designation, and room name
3. Fixture and/or lamp type of controlled lighting zone, including any information describing custom fixtures, undetermined fixtures, dimmable transformers or fluorescent ballasts, and circuit breaker numbers. This information can also contain the number assigned to the controlled circuit
Specifying a Lighting System
4. Load type of the controlled lighting zone: load types include incandescent, magnetic low voltage, electronic low voltage, neon/cold cathode, HID, dimmable/non-dimmable fluorescent ballast, ceiling fans, and switched 3-wire motor circuits. This information is especially important for selecting the correct Crestron module power rating and type
5. Dimming requirement for the controlled lighting zone (i.e. whether the lighting level of the loads/fixtures needs to be ramped up/down or simply switched on/off). Indicate: “Yes” for
Dimming, and “No” for Non-Dim
6. Emergency designation for the controlled lighting zone (yes/no; i.e. when a load needs to be assigned to a separate emergency power feed). These items are assigned to their own separate dimmer, so they can be fed with emergency power
7. Voltage rating for the controlled lighting zone tells the designer the voltage of the electrical feeds required for that zone, and hence the required rating for the associated Crestron module.
8. Fixture wattage (watts or power rating per fixture) with regard to the controlled lighting zone: this is used to determine the number of fixtures that can be powered per each Crestron Dimmer Module channel, in order not to overload the dimmer beyond its power rating
9. Quantity of fixtures for the controlled lighting zone: this is useful, along with item #6, in calculating the total power rating (watts) for that particular controlled circuit (item #9)
10. Total wattage, or power rating, of the controlled lighting zone: This is required in order to determine the total number of Crestron Lighting Module channels required for that particular zone, especially if the load of the total number of fixtures exceeds the rating of a single module channel
NOTE: National and local electrical codes and the functionality of each user interface must be taken into consideration. Always install electrical devices according to the national Electrical Code (NEC), local codes, and with safety in mind.
Doc. 5999F 8
Crestron Residential Lighting Design Guide Specifying a Lighting System
Example Load Schedule with Panel Terminations
Area Room
Main Floor Bathroom 1 Downlights
Main Floor Bathroom 1 Downlights 2
Main Floor Bathroom 1 Downlights 3
Main Floor Bathroom 1 Drapes
Main Floor Bathroom 1 Exhaust Fan
Main Floor Bathroom 2 Downlights
Main Floor Bathroom 2 Downlights 2
Main Floor Bathroom 2 Drapes
Main Floor Bathroom 2 Exhaust Fan
Main Floor Bedroom
Main Floor Bedroom
Ceiling Fan
Downlights
Main Floor Bedroom Downlights 2
Main Floor Bedroom Downlights 3
Main Floor Bedroom Downlights 4
Main Floor Bedroom Downlights 5
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Drapes
Drapes 2
Drapes 3
Main Floor
Main Floor
Foyer
Sauna
Downlights
Drapes
002
001
018
017
016
022
005
004
003
013
020
007
011
010
021
012
009
008
006
019
Controlled Ckt
Name
Controlled
Ckt No. Fixture Load Type Dim Emergency
Fixture
Watts
Fixture
Qty
Total
Watts Enclosure Slot Module Output
Downlights Incandescent yes no 100 1 100 Enclosure
Downlights Incandescent yes no 100 2 200 Enclosure 1 2 CLX-1DIM8
Downlights Incandescent yes no 100 2 200 Enclosure
Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 4 CLX-1MC4
Exhaust Fan Switched no
Downlights Incandescent yes no no
200
100
1
1
200
100
N / A
Enclosure 1
N / A Interface 2
2 CLX-1DIM8
Downlights Incandescent yes no 100 3 300 Enclosure
Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 4 CLX-1MC4
Exhaust Fan Switched no no 200 1 200 N / A N / A Interface 4
2
Ceiling Fan Ceiling Fan no no 100 1 100 Enclosure 1 6 CLX-1FAN4
Downlights Incandescent yes no 250 2 500 Enclosure
Downlights
Downlights
Incandescent
Incandescent yes yes no no
100
100
4
1
400
100
Enclosure 1
N / A
3
N / A
CLX-1DIM4
Interface 6
Downlights Incandescent yes no 100 1 100 N / A N / A Interface 5
Downlights Incandescent yes no 100 2 200 Enclosure
Drapes
Drapes
Drapes
3-Wire Motor
3-Wire Motor
3-Wire Motor no no no no no no
200
200
200
1
1
1
200
200
200
Enclosure 1
Enclosure 1
Enclosure 1
4
4
5
CLX-1MC4
CLX-1MC4
CLX-1MC4
Downlights Incandescent yes no 100 4 400 Enclosure 2
Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 5 CLX-1MC4
*Calculation of load wattage includes transformer loss.
2
3
4
1
1
1
1
2
1
1
1
1
4
The complete diagram is available on line at: http://www.crestron.com/dealer-tech_resources/application_diagrams.asp
.
Doc. 5999F 9
Specifying a Lighting System Crestron Residential Lighting Design Guide
Residential Lighting Wiring Plan
The wiring plan includes all enclosures and the interconnecting wiring. The designer determines the location of the enclosure(s), the route of keypad and touchpanel connections to the enclosure(s), the route of the interconnecting cable from the processor to the other enclosure(s), and the high voltage load routes to the enclosure or dimmer.
Ensure there are enough connectors and power (PAC2 offers
50W) in the main enclosure for all user interfaces. Each enclosure filled with dimmers is connected to the main enclosure and processor using low voltage wire. Dimmer enclosures are distributed as needed.
Equipment List Specification
The equipment list is based on the requirements collected for the lighting system in the load schedule. This is a sequential process. The information gathered in previous steps is required to complete the next. Once all the steps are completed, a complete Bill of Material for the system is created.
Module selection – based on the number and type of loads
Automation enclosure selection – based on the number of modules and the available space in the enclosure
User interface selection – based on the user control requirements
Wiring plan – based on the previous steps and the layout of the environment
Control processor – based on the size of the system
(large systems should have a dedicated processor)
Network block selection – based on the layout and distribution of the loads and user interfaces
Accessories selection – based on the required accessories (telephone and alarm systems, HVAC control, intercom systems, occupancy sensors, etc.)
Ordering a Crestron Residential
Lighting System
These are the steps for ordering a Crestron Residential lighting control system, regardless of the size.
Each system and module contains the appropriate installation literature and operation guide.
Steps to order a lighting system:
STEP 1 : Survey all controlled lights and loads. In hybrid systems determine which loads are under local control and which are to be wired to centralized modules
STEP 2: Determine the number and types of control modules and terminal blocks needed to control lights and loads based on the load schedule and wiring plan
STEP 3: Determine the number and type of automation enclosures required
STEP 4: Determine the number of control processors and related accessories required
STEP 5: Determine the number and types of keypads, wall panels, iLux™ devices, infiNET™ wireless devices, shade/drape controllers, and touchpanels
STEP 6: Determine the wiring accessories, cabling and power supplies required
STEP 7: Place an order for identified Crestron items
Nearly all required documentation, such as load schedules and wiring, equipment lists, engraving files and more can be generated by using the Crestron D3 Pro Lighting and
Automation System Software.
Crestron ships all items to the job site for assembly and wiring.
NOTE : If engraving is desired on infiNET devices, IT MUST BE
SPECIFIED UPON ORDER. Due to UL restrictions, the button caps cannot be replaced in the field. Therefore, only new units must be engraved before leaving the Crestron factory.
Doc. 5999F 10
Crestron Residential Lighting Design Guide GreenLight Options–CAEN Enclosures
Green Light Options
CAEN- Series Enclosures
The CAEN Series automation enclosures are designed to house the Crestron CLX-series of lighting and motor control modules and PAC2 or PAC2M control systems. CAEN enclosures are available in an assortment of sizes, suitable for surface or flush wall mount installation. Each model has been engineered to provide a clean and manageable installation with abundant provisions for wire termination and electrical knockouts.
CAEN automation enclosures are designed to use space efficiently by supporting over a hundred possible circuits in the largest model. Both centralized and distributed configurations are possible. A single PAC2 control system installed in a central enclosure can support numerous satellite extension enclosures distributed throughout a residence or commercial facility. Interconnection of the complete network of enclosures requires just one circulating Cresnet® cable. Dozens of keypads, touchpanels, wall box dimmers, shade controllers, and other peripherals can also be terminated within an enclosure, with separate compartments provided for high and low voltage wiring.
Crestron lighting and automation systems are completely convection cooled for silent and reliable operation. A vented front cover is included with every enclosure.
All models are constructed of 16-gauge galvanized steel and are pre-drilled for mounting of the PAC2, PAC2M, terminal blocks, CLX modules, CLT power supplies, and CAEN-BLOCK terminal block.
Additional non-CLX lighting modules and third-party contactors may be installed using CAEN-UMP Crestron universal mounting plates. Grounding blocks and low voltage partitions included.
CAEN enclosures are also well suited for all types of Class 2 and Class 3 applications including voice and data structured wiring, security, and RF signal distribution (as permitted by applicable codes).
CAEN enclosures are UL and C-UL listed. If you require a complete UL listed panel, Crestron offers this service through its UL508 listed panel shop, providing complete in-factory system configuration and assembly.
NOTE: The PAC2 occupies two module spaces in a doublewide enclosure and one module space in a single-wide.
NOTE: Four keyholes are located within the enclosure and should be used if surface mounting.
Doc. 5999F 11
CAEN Enclosures Crestron Residential Lighting Design Guide
CAEN-Series Enclosure
Specifications
Module Capacity
Required Flush Mount Opening
(Width) x (Height)
Construction
CAEN Model
7X2* 7X1 4X2* 4X1 2X1
14
25 ½” x 62”
7
14 ⅜” x 62”
8
25 ½” x 38 ⅞” 14
4
⅜” x 38 ⅞” 14
2
⅜” x 23 ½”
Regulatory Approvals
Mounting
16 gauge galvanized sheet metal
Cover is painted metal with ventilation holes
UL and C-UL listed
Surface or flush mounted
*Double-width enclosures are either surface mounted or framed accordingly
CAEN-Series Dimensions (Front and Side Views)
W
W
W
W
W
H
W
H
W
W
H
D
CAEN Dimensions
1
H1
H2
H3
W1 26 ½
62
56
2
15
11
/
16
⅜
32
⅞
26 ½
38 ⅞ 23
2 ⅛
34 18
⅝
15
⅜
W2
W3 2 ½ 1 ¾ 2 ½ 1 ¾
W4
W5
5 20 ½ 9
⅞
20 ½ 9
⅞
W6
D1
Cover Thickness
Cover Height
4
⅛
1
/
16
62 ¾
27 ¼
39 ⅝
16 ⅛ 27
24 ¼
16 ⅛
Cover Width
Weight
2
Empty
3 65 42 43 28
Weight Full
4
1. Dimensions are in inches.
2. Weight is in pounds.
3. Weight Empty includes the cover.
4. Weight Full is with the maximum number of modules installed.
5. The lower keyholes are not symmetrically spaced in single-width enclosures.
19
Doc. 5999F 12
Crestron Residential Lighting Design Guide
CAEN Installation
In accordance with all national and local codes a licensed electrician must mount the enclosure. Special attention must be made to NEC Article 110.26(A)(2) concerning minimum work space requirements.
When choosing components to place in CAEN enclosures, refer to the table on the previous page to ensure that the maximum weight capacity is not exceeded. The weight of each module is listed on the product page on the Crestron website.
CAUTION: These enclosures house equipment that requires air cooling. Therefore, mount in a well-ventilated area. The ambient temperature range should be 32°F to 104°F (0°C to 40°C). The relative humidity should range from 0% to 90% (non-condensing). Furthermore,
CAEN Enclosure Framing
CAEN enclosures 2X1, 4X1, and 7X1 fit between standard wall stud spacing (16 inches on center).
CAEN 2X1, 4X1, and 7X1 Framing
GreenLight Options–CAEN Enclosures allow adequate clearance in front of the vented cover for servicing and ventilation.
NOTES: Unless otherwise indicated, the lighting system specified in this guide is modular, requiring assembly in the field by a licensed electrician in accordance with all national and local codes. If you require a UL listed panel,
Crestron offers this service through its UL listed panel shop. This includes complete in-factory system configuration and assembly by Crestron for an additional fee. All commercial lighting systems include factory assembled, UL listed panels.
Install modules into the lowest available spaces and continue toward the top of the enclosure.
Enclosures are intended for indoor use only.
When flush mounting, 5/8” drywall is preferred.
CAEN enclosures 4X2 and 7x2 require framing modification. The weight of the enclosure rests on a sill plate, and does not distort the surrounding wallboard.
CAEN 4X2 Framing
Doc. 5999F 13
GreenLight Options–CAEN Enclosures Crestron Residential Lighting Design Guide
CAEN Wiring
CAUTION: All power feeds must be protected by 15 or 20 amp circuit breakers (supplied by others).
NOTES: Use copper conductors only – rated 75°C
All wiring must be installed in accordance with all local and national electrical codes.
Two snap bushings are supplied. If required, insert into knockouts at the bottom of the enclosure to prevent damage to low voltage wiring.
Class 2 field wires must be kept separate. Refer to the illustration showing singlewide and doublewide wiring details. Areas for high voltage (Class 1) wiring are shown along the top and side(s) of the unit. The lower area is reserved for low voltage (Class 2) wiring.
Tighten all CLT-Series terminal block screws and grounding terminal block screws to the torque specified in the Torque Data table.
CAUTION: Failure to properly tighten the screws may result in poor electrical connection and overheating of the terminals.
Wire Range &
Torque Data
Wire Range
Torque (In-Lbs)
CLT
Terminal
Blocks
22 - 10
9
Grounding Terminal
Blocks
14 - 10 8 6 - 4
35 40 45
Doc. 5999F 14
Crestron Residential Lighting Design Guide GreenLight Options–CAEN Enclosures
Universal Mounting Plates
Crestron Universal Mounting Plates (CAEN-UMP Series) are a complete line of accessory plates, which allow mounting of non-Crestron equipment to any Crestron
Automation Enclosure (CAEN Series). Third-party products such as phone and alarm systems can be mounted to these plates. The advantage to using the CAEN-UMP is that a variety of sizes are available and each plate occupies the same area as one, two or four Crestron lighting modules (CLX-series).
The size corresponds to the number of module spaces and their arrangement within the enclosure. For example, CAEN-UMP2X2 occupies four module positions and
CAEN-UMP1x1 occupies one module position. The others (CAEN-UMP2X1 and 1X2) occupy two module positions. Refer to the illustration for an example of plate location and orientation within a double-wide enclosure. The table below lists the dimensions and weight for each CAEN-UMP model. The CAEN-UMP must be mounted in accordance with all national and local codes.
Use the four supplied (8x1/4”) screws to attach a CAEN-UMP to an enclosure. Crestron recommends that the keyholes on the plates be located toward the outer edge of the enclosure,as shown in the illustration. As a result, the flanges of the plates do not overlap each other when positioning any combination of
CAEN-UMP2X1s, CAEN-UMP1X1s, or lighting modules side-by-side in an enclosure.
NOTES: Adhere to Class 1 versus Class 2 wiring requirements when considering the equipment attached to the CAEN-UMP in an enclosure.
Third-party equipment attached to a CAEN-UMP within a Crestron Automated
Enclosure should not be considered part of the Crestron system.
CAEN Universal
Mounting Plate
2X2 2X1 1X2 1X1
Weight
Height
Depth
22.6 12.0 12.4 6.6
15
1
/
8
15
1
/
8
7
7
/
16
7
7
/
16
6
16
/
16
5
/
8
Dimensions are provided in inches, edge to edge.
Weight is provided in ounces.
Doc. 5999F 15
GreenLight Options–CAEN Enclosures Crestron Residential Lighting Design Guide
Cover Extension Kits
The Cover Extension Kits are designed to increase the overall depth of the automation enclosures by 1.5 inches. Adding depth to these enclosures accommodates excess wiring and third-party devices that may not normally fit in the standard enclosure.
Doc. 5999F
CAEN Cover
Extension Kit
Height
CAEN-
CK-2X1
23.5
CAEN-
CK-4X1
38.9
CAEN-
CK-4X2
38.9
CAEN-
CK-7X1
62
CAEN-
CK-7X2
62
15.35 26.5 Width 15.35 15.35 26.5
Depth
Dimensions are provided in inches.
1.5
16
Crestron Residential Lighting Design Guide GreenLight Options–CAEN Enclosures
CLX Lighting Control Modules
Concealed in Crestron automation cabinets, the CLX-series devices are rigorously built using oversized heat sinks for ultimate reliability.
Split-bobbin transformers and ground-referenced electronics deliver superior performance
Lamp flicker is minimized through the innovative Crestron zero-crossing detection technique, backed by proprietary firmware
Low-maintenance convection cooling assures quiet and trouble-free operation
Noise suppression inductors and international 230V versions are available
LEDs on the modules indicate communication to a Cresnet® network, input power to the module, and output power to the load
A five-pin ribbon cable interconnects modules and the processor
NOTE: CLX modules and their associated CLT terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure.
CAUTION: A bypass jumper is provided to allow testing and to protect the module during installation. When properly secured by nine screws, the jumper on the black and red section of the terminal block shorts the LINE in to DIM out so that the circuit is energized. Do not remove the bypass jumper until all feed and load wiring has been completed, the circuit has been tested for electrical faults, and the module has been installed.
Furthermore, the jumper on the white section of the terminal block ties the neutral in to the neutral outs. This jumper should never be removed.
Doc. 5999F 17
GreenLight Options–CAEN Enclosures Crestron Residential Lighting Design Guide
CLX-Series Lighting Control Modules
Model Load Rating
CLX-1DELV4 Four channels of dimming for electronic low voltage and incandescent loads
Each channel is rated for 1200 watts, with a total module rating of 1920 watts when fed from a 20A breaker. A total module rating of 1440 watts when fed from a 15A breaker
NOTE: CLW series dimmers are not compatible with CLX-1DELV4
CLX-1DIM4 Four channels of dimming for incandescent, magnetic low voltage, neon/cold cathode, and dimmable
2-wire fluorescent loads
Each channel is rated for 1920 watts, with a total module rating of 1920 watts when fed from a 20A breaker. A total module rating of 1440 watts when fed from a 15A breaker
CLX-1DIM8 Eight channels of dimming for incandescent, magnetic low voltage, neon/cold cathode, and dimmable
2-wire fluorescent loads
Each channel is rated for 1920 watts, with a total module rating of 1920 watts when fed from a 20A breaker. A total module rating of 1440 watts when fed from a 15A breaker
CLX-2DIM2 Two independent channels of dimming for incandescent, magnetic low voltage, neon/cold cathode, and dimmable 2-wire fluorescent loads.
Each channel is rated for 1920 watts; with a total module rating of 3840 watts when fed from two separate 20 A feeds, and a total module rating of
2880 watts when fed from two 15A breakers.
CLX-2DIM8
CLX-1FAN4
Eight channels of dimming for incandescent, magnetic low -voltage, neon/cold cathode, and dimmable
2-wire fluorescent loads, actually composed of two independent fourchannel dimmers in a single module
Capacitive-type speed control for up to four ceiling fan motors
Each channel is rated for 1920 watts; with a total module rating of 1920 watts when fed from a 20A breaker. A total module rating of 1440 watts when fed from a 15A breaker
Each channel provides four preset speed settings plus off and is rated for 2 amps, with a total module rating of 8 amps
CLX-1MC4 Control of up to four bidirectional motors for drapes, blinds, projection screens, lifts, etc.
Each channel is rated for 10 amps or 1/2 HP, with a total module rating of
16 amps.
CLX-4HSW4 Four independent channels of switching for high-inrush loads such as motors, HID lighting, and fluorescent ballasts, as well as incandescent, low voltage, and neon/cold cathode lighting
Each channel is rated for 16 amps or 1/2 HP; with a total module rating of
64 amps when fed from four separate 20 amp feeds.
Doc. 5999F 18
Crestron Residential Lighting Design Guide GreenLight Options–CAEN Enclosures
Terminal Blocks and Modules
The Crestron CLT terminal blocks and modules are considered a single entity and must be used together. In field-assembled panels, they ship separately to permit termination of the field wiring to the terminal block prior to the installation of the module, and are mounted in any Crestron
Automation Enclosure (CAEN-series enclosures). The terminal block is designed to terminate the circuit feed (HOT and NEUTRAL) and distribute the controlled circuit (LOAD) to the fixture(s).
The module connects to the terminal block and performs dimming or switching control of the loads, limited to 16A total per module. The unit requires 120VAC 60 Hz, single phase input voltage.
An oversize heat sink dissipates heat efficiently. The LEDs on the module indicate communication to a Cresnet® network, input power to the module, and output power to the load.
Terminal Blocks, Rails, and Labels (Inverted, right side units shown)
NOTES: When connecting dimming loads to an arc fault breaker, the load should not exceed 1000 watts per breaker.
Each terminal block includes a terminal rail for mounting the terminal block in the enclosure. Terminal rails and blocks do not occupy a module space within an enclosure.
Terminal blocks are installed along the left side of single-wide enclosures and along the outside edges (left and right sides) of enclosures. Modules are installed along the right side of single-wide enclosures and side-by-side in the center of enclosures.
When installing modules and terminal blocks in a double-wide enclosure, be sure to invert units on the right side so that they can be properly wired.
Doc. 5999F 19
GreenLight Options–CAEN Enclosures Crestron Residential Lighting Design Guide
Module Installation
In accordance with all national and local codes a licensed electrician, , must mount the terminal blocks and modules in field-assembled Crestron Automation Enclosures.
Terminal blocks are installed along the left side of singlewide enclosures and along the outside edges (left and right sides) of doublewide enclosures. Modules are installed along the right side of singlewide enclosures and side-by-side in the center of doublewide enclosures.
Refer to the illustrations when considering the location of terminal blocks and modules within an enclosure.
Single Width Enclosure Mounting
Module and associated terminal block installed in single width enclosure are shown below. The PAC2 processor occupies the lowest module position
CAUTIONS: This equipment is for indoor use only and requires air cooling. Mount in a well-ventilated area.
The ambient temperature must be 32°F to 104°F
(0°C to 40°C). The relative humidity must be 0% to 90%
(non-condensing).
Modules contains electrostatic sensitive devices (ESDs) and units must be handled from metal chassis – do not touch PC board or components.
NOTES: Modules and terminal blocks must be installed into the lowest available spaces and continue toward the top of the enclosure.
Modules are installed after the enclosure has been completely wired.
Double Width Enclosure Mounting
Module and associated terminal block installed in double width enclosure are shown below. The PAC2 processor occupies the lowest module position.
Terminal Rail Bypass Jumpers
CAUTION: A bypass jumper is provided on the terminal rail to allow testing and to protect the module during installation.
When properly secured by nine screws, the jumper on the black and red section of the terminal block shorts the LINE in to
DIM out so that the circuit is energized. Do not remove the bypass jumper until all feed and load wiring has been completed, the circuit has been tested for electrical faults, and the module has been installed. Furthermore, the jumper on the white section of the terminal block ties the neutral in to the neutral outs. This jumper should never be removed.
NOTE: Use copper conductors only – rated 75°C.
Doc. 5999F 20
Crestron Residential Lighting Design Guide DIN Rail Products
Cresnet® Terminal Block for CAEN Automation Enclosures
The CAEN-BLOCK is a Cresnet terminal block designed specifically for
Crestron lighting and automation systems to link remote enclosures to the central PAC2 or PAC2M control system. The CAEN-BLOCK mounts at the bottom of each CAEN enclosure that does not contain a control system to provide Cresnet and override signal connectivity for CLX-series lighting control modules. The CAEN-BLOCK serves as a parallel distribution block for multiple Cresnet cables, and especially provides for connection of the Cresnet and override signal cables from the central control system.
Crestron Network Block (CAEN-BLOCK) provides four termination ports for Cresnet wiring. The unit has two 5-pin connections that provide communication to the modules. Contact closure signals that produce an emergency override of the modules are also sent through these connections .
When a switch contact closure is received between the “G” connections and the “L” or “R” connection (R is used in a double-wide enclosure only) on the CAEN BLOCK, the respective left or right column of modules will set the lights to the programmed emergency override state.
The CAEN-BLOCK unit is a pass-through device with a Cresnet power factor of zero.
Network Block Dimensions and Weight
Height Width Depth Weight
2 in 6 in 1 ¾ in 3.4 oz
NOTES: A module terminal block (CLT-series device) must be ordered for each module. The corresponding CLT terminal block is installed in the enclosure for high voltage wire termination. Each terminal block includes a terminal rail for mounting the block in the enclosure. Terminal rails and blocks do not occupy a module space within an enclosure.
CAEN-series enclosures are required to install CLX-series lighting modules.
Doc. 5999F 21
GreenLight Options–CAEN Enclosures Crestron Residential Lighting Design Guide
NOTE: If more than 50 watts of power is drawn by connected devices, supplemental power supplies are required.
Doc. 5999F 22
Crestron Residential Lighting Design Guide DIN Rail Products
Crestron DIN Rail Products
Features
Popular in Europe and ideal for MDU applications
High voltage units rated for use up to 240VAC, 50/60Hz
Integrated Emergency Override Mode
Mix and match Crestron and 3 rd party products in oOne enclosure
DIN Rail Installation
The Crestron DIN Rail products are designed to snap onto a standard DIN Rail for installation in a wall mount enclosure. Wiring connections are made using screw terminals positioned along the bottom and/or bottom, clearly accessible from the front for easy installation and servicing. All setup controls and indicators are positioned on the center front panel.
When installed in an enclosure utilizing 45 mm cutouts, the front panel remains accessible while the connections are concealed. DIN modules may be mounted in CAEN enclosures or in DIN Rail cabinets available from a number of 3 rd party vendors.
Cabinets are available in many sizes.
DIN Rail devices may also be used with Crestron CAEN Cabinets.
Doc. 5999F 23
Crestron Residential Lighting Design Guide DIN Rail Products
Example DIN Rail System
Doc. 5999F 24
Crestron Residential Lighting Design Guide DIN Rail Products
DIN-AP2
2-Series Processor
Built upon the reliable Crestron 2-Series control engine, the DIN-AP2 is extensively programmable using the suite of powerful Crestron development software and vast database of drivers and software modules. The DIN-AP2 works seamlessly with the entire line of Crestron lighting dimmers and shade controls, keypads and touchpanels, thermostats, wireless gateways, and expansion modules.
The DIN-AP2 is a 2-Series control processor designed for small to medium-sized lighting and automation applications. DIN Rail mounting enables modular installation alongside Crestron DIN Rail lighting and automation control modules and other third-party DIN Rail mountable devices.
Features
2-Series control engine
MMC memory expansion card slot
Cresnet port - master/slave selectable
10/100 Ethernet | SSL encryption
e-Control 2, SNMP and RoomView support
2 bidirectional RS-232 COM ports
4 IR/serial ports
8 Versiport I/O ports
4 Low-voltage relay ports
Configurable via Crestron D3 Pro software
Memory Expansion
A memory card slot allows for easy expansion of the DIN-
AP2 internal memory using an MMC-compatible memory card up to 2 GB.
Ethernet and e-Control®2
Built-in 10/100 Ethernet facilitates secure high speed network connectivity, enabling extensive capabilities for remote system maintenance and control, and providing an interface to other Crestron control systems. Native features include a built-in email client to report system
System Integration
The DIN-AP2 provides for the integration of non-Crestron devices and subsystems through a host of control interfaces. Four isolated relays and eight Versiport I/O ports are built in to accommodate all kinds of sensors, contactors, door strikes, and other low voltage controls.
Two bidirectional RS-232 COM ports and four IR/serial ports allow for the integration of everything from simple troubles and other functions to the owner or service company via instant email notification. An onboard Web server provides the foundation for the exclusive Crestron e-Control 2 XPanel technology, providing secure IP-based remote control.
RoomView® and SNMP
For large facilities utilizing multiple DIN-AP2s and other shade controllers to advanced security systems.
Cresnet ®
Cresnet is the communications backbone for Crestron lighting modules, wall box dimmers and shade controllers.
The DIN-AP2 includes a pair of Cresnet master ports
(paralleled) capable of supporting approximately 20 typical devices. Larger systems with more than 20 devices can be handled by adding the DIN-HUB Cresnet control systems, exclusive Crestron RoomView Help Desk software delivers a comprehensive solution for remote monitoring and asset management. Also, built-in SNMP support enables similar capability using third-party network management software, allowing full control and monitoring from the IT Help Desk or NOC in a format that's familiar to IT personnel.
D3 Pro™ Software Distribution Hub. Connectivity for multiple homeruns can be facilitated using one or more DIN-BLOCK Cresnet
Distribution Blocks. Additionally, at least one DIN-PWS50
Cresnet Power Supply is required to power the DIN-AP2 and any connected Cresnet devices.
Crestron D3 Pro software eliminates the need for custom programming, providing a complete design, development, and documentation solution for the lighting professional.
Doc. 5999F 25
Residential Lighting Design Guide DIN Rail Products
DIN-1DIMU4
Features
4 channels of forward or reverse phase dimming
Auto load detection
120 to 240 Volt 50/60 Hz operation (Not for 277 VAC operation)
Selectable non-dim mode
Extreme stability in noisy environments
Auto Load Detection
Each channel of the DIN-1DIMU4 is capable of autodetecting the dimmable load type connected to it and selecting the appropriate operating mode to control that load. Reverse phase (trailing edge) mode supports incandescent and electronic low-voltage load types, while forward phase (leading edge) mode handles magnetic low voltage, neon, and other inductive load types. A non-dim mode is also selectable for switching of non-dimmable lighting fixtures. Any channel may be set for any mode, allowing one dimmer module to handle any combination of lighting types on four separately controlled circuits.
Phase-Synchronous Detection Circuitry
Proprietary Crestron zero-cross filter technology provides
The DIN-1DIMU4 is a 4-channel universal lighting control module designed to support dimming of both forward and reverse phase type loads. A single model supports 120 and 220-240 volt electronic and magnetic low voltage, incandescent, neon/cold cathode, 2-wire dimmable fluorescent, and non-dimmable lighting loads up to 5 amps per channel, 10 amps total.
Short circuit and overload protection
Master air-gap relay
Setup via front panel or software
Programmable functionality via DIN-AP2 superior immunity to noise on the power line, reducing lamp flicker and compensating for fluctuations in line voltage and frequency.
Short Circuit Protection
Built-in OCP (over current protection) prevents failure of the DIN-1DIMU4 caused by excessive loading or improper wiring of the outputs.
Master Air-Gap Relay
When all four channels are turned fully off, the internal master relay automatically opens, providing air-gap isolation that allows safe servicing and changing of light bulbs on all four controlled circuits.
Doc. 5999F 26
Crestron Residential Lighting Design Guide
DIN-8SW8
DIN Rail Products
The DIN-8SW8 is an 8-channel high voltage lighting control module designed to support switching of non-dimmable lighting and fans. A single model supports both 120 and 220-
240 volt applications. Each channel handles incandescent loads up to 10 amps, fluorescent loads up to 5 amps, and also 1/2 HP motors.
Features
8 channels of power switching
Supports 120 to 240 volt 50/60 Hz (Not for 277
VAC operation)
Override input
Cresnet® communications
Setup via front panel or software
Programmable functionality via DIN-AP2
DIN-4DIMFLV4
The DIN-4DIMFLV4 is a 4-channel lighting control module designed to support dimming of 4-wire 0-10 volt fluorescent dimming ballasts. A single model supports both
120 and 220-240 volt applications. Each channel handles up to 30 dimmable ballasts, and may also be used for switching of non-dimmable lighting loads up to 5 amps, as well as 1/2 HP motors.
Features
4 channels of 4-wire 0-10 volt fluorescent dimming
Supports 120 to 240 Volt 50/60 Hz (Not for 277
VAC operation)
Also allows switching of lighting and exhaust fans
Setup via front panel or software
Programmable functionality via DIN-AP2
DIN-2MC2
The DIN-2MC2 is a 2-channel motor control module designed to provide control of bidirectional motors for drapes, shades, projection screens, lifts, skylights, and gates. Each channel supports up/down or open/close control of a conventional 3-wire bidirectional type motor up to 1/2 HP at voltages up to 240 volts. Built-in timing and interlock logic make it easy to program the DIN-2MC2 for failsafe operation.
Features
Dual-channel bidirectional motor control
Supports 120 to 240 volt 50/60 Hz
Setup via front panel or software
Programmable functionality via DIN-AP2
Doc. 5999F 27
Crestron Residential Lighting Design Guide
DIN-AO8
DIN Rail Products
The DIN-AO8 is a DIN Rail-mounted automation control module that provides eight analog output ports for interfacing with third-party lighting and heating/cooling systems.
Analog Outputs
Each analog output port provides a 0 to 10 volt DC control signal ideally suited for controlling 0-10V lighting dimmers and heating/cooling valves. 10-bit resolution ensures precise recall of lighting and climate control settings and smooth ramping between levels.
Features
Eight 0-10V analog output control ports (Maximum sink current
20mA per channel)
Interface for 3rd-party lighting and heating/cooling
Fully programmable functionality via DIN-AP2 Setup via front panel or software
DIN-IO8
The DIN-IO8 is a DIN Rail-mounted automation control module that provides eight Versiport I/O ports for interfacing with a wide range of third-party devices and systems. Each Versiport can be configured via software to function as a digital or analog sensing input or as a digital trigger output.
Features
8 Versiport I/O ports
Interface for 3rd-party sensors, detectors, contact closures, and alarms
Fully programmable functionality via DIN-AP2
Versiports
Configured as a digital input, the Versiport senses a contact closure or logic level signal from devices such as motion detectors, partition sensors, alarm panels, 12V triggers, and all types of switches and relays. As an analog input, the Versiport can sense changes in a resistance or DC voltage level, working with everything from temperature and light sensors to water level meters to volume control potentiometers. As a digital output, the Versiport provides a logic level closure signal to trigger control and alarm inputs on a variety of external devices.
Doc. 5999F 28
Crestron Residential Lighting Design Guide
DIN-BLOCK
DIN Rail Products
The DIN-BLOCK is a DIN Rail-mounted Cresnet® distribution block designed to facilitate the termination of Cresnet wiring at a head end or distribution point. DIN Rail mounting enables modular installation alongside Crestron
DIN Rail lighting and automation control modules and other third-party
DIN Rail mountable devices.
Features
12 port Cresnet distribution block
Detachable screw terminal blocks for easy termination and troubleshooting
Split power bus for flexible 24V power distribution
Diagnostic LEDs for network power and data
Passive device — no programming required
Cresnet Distribution
Cresnet is the communications backbone for Crestron lighting modules, wall box dimmers, shade controllers, thermostats, keypads, touchpanels, and many other devices. This flexible 4-wire bus allows for combinations of homerun and daisy-chain wiring, and the DIN-BLOCK provides a simple means for connecting up to 12 separate Cresnet cables as part of any sized network.
Cresnet Power Distribution
In addition to data, Cresnet carries 24 volts DC for powering the devices connected to it. The Cresnet ports on the DIN-BLOCK are arranged into two separate power groups, providing an easy way to manage the distribution of power for a complete Cresnet network. A separate power supply may be dedicated to each group, or a single supply can be connected to both groups as needed. Each group supports up to 75 watts.
DIN-PWS50
The DIN-PWS50 is a 50 watt Cresnet power supply module designed to snap onto a standard DIN Rail installation. DIN Rail mounting enables modular installation alongside Crestron DIN Rail lighting and automation control modules and other third-party DIN Rail mountable devices. All wiring connections are made using screw terminals positioned along the top and bottom, clearly accessible from the front for easy installation and servicing. Three Cresnet power ports are provided.
Features
50 watt Cresnet power supply module
Powers the DIN-AP2 Automation Processor and other Cresnet devices
Includes 3 Cresnet power ports
Cresnet data passes through unaffected
Dual line power input terminals for easy daisy-chaining
Doc. 5999F 29
Crestron Residential Lighting Design Guide
DIN-HUB
DIN Rail Products
The DIN-HUB is a DIN Rail-mounted Cresnet® hub designed to facilitate the configuration of large Cresnet networks. DIN Rail mounting enables modular installation alongside Crestron DIN Rail lighting and automation control modules and other third-party DIN Rail mountable devices.
Features
3-segment Cresnet hub
32 Cresnet devices per segment
3-Segment Cresnet Hub
Cresnet is the communications backbone for Crestron lighting modules, wall box dimmers, shade controllers, thermostats, keypads, touchpanels, and many other devices. This flexible 4-wire bus normally supports approximately 20 Cresnet devices without requiring a hub. Larger systems are easily enabled by adding the DIN-HUB. The DIN-HUB features three isolated Cresnet segments, each supporting an additional 20 devices, allowing for systems of approximately 80 devices total (including the
"host" segment). More hubs may be added to allow up to a maximum potential of 252 devices.
Cresnet Power Distribution
In addition to data, Cresnet carries 24 volts DC for powering the devices connected to it. The DIN-HUB provides an easy way to manage the distribution of power for a complete Cresnet network. Each segment can be configured to receive its power from the "host" power source or from another power supply. Separate power supplies may be dedicated to each segment, or a single supply can be shared amongst multiple segments as needed. Each segment supports up to 75 watts.
Doc. 5999F 30
Interface Equipment Residential Lighting Design Guide
Interface Equipment
Integrating your lighting with A/V controls, shade control, security systems, and HVAC through a single system have never been easier. Crestron provides the ultimate, fully integrated lighting control solution for any application.
Dimming control
Switched control
Sensor activated control
Security
Astronomical clock control
Remote monitoring of any location
Crestron eliminates all system integration problems by providing the single point control solution coupled with the widest selection of control devices. Crestron products are designed to operate efficiently, replacing several products and drawing less power.
Crestron products and automation solutions help designers meet ASHRAE (American Society of Heating,
Refrigeration, and Air-Conditioning Engineers) and LEED
(Leadership in Energy and Environmental Design) standards. Crestron products are also in compliance with the European Union (EU) Directive 202/95/EC Restriction of Hazardous Substances (RoHS).
Additional Crestron product information and specifications are available from the Crestron web site: www.crestron.com
Crestron User Interfaces
Crestron offers a wide variety of types and styles to suit the needs and tastes of your client.
User interfaces are prominently and strategically located throughout a lighting design, providing the physical link between the user and the controlled devices.
Touchpanels
Crestron touchpanels are the most elegant, efficient and practical control solution, simplifying the most demanding design and providing intuitive one-touch control of lighting, AV, HVAC, and security.
With distinctive features for every application, the broad range of Crestron touchpanels delivers maximum value.
There is a Crestron touchpanel for every room and every budget.
Keypads
C2N-DB Decorator Series Keypads bring a contemporary design to traditionally flat faceplates. They are available in a wide selection of finishes and offer extra large, backlit buttons for custom engraving. They also play door chimes, voice prompts, button clicks and other audible feedback, depending on programming. These keypads use readily available Decora® style faceplates.
CNX Designer Series Keypads are an elegant option for any décor. Extra large backlit buttons offer room for custom engraving. They can also play door chimes, voice prompts, button clicks and other audible feedback.
C2N-CBD and C2N-CBF Series Cameo™ Keypads answer the need for a diverse selection of designer colors, and dramatically reducing the standard keypad wall plate size without comprising button size. Mounting options include a choice of standard installation in a Decora® style faceplate or using the Crestron exclusive flushmounting system. Cameo is offered in 10 designer colors, plus three standard colors.. The installer can customize and configure up to six buttons for 12 functions in total.
Wall Box Dimmers and Switches
These devices are functional as a stand-alone dimmers or switches, and deliver greatly enhanced functionality as part of a complete Crestron Control solution. Designed to replace any standard in-wall dimmer or light switch, when connected to a 2-Series control system via the Cresnet network, extensive automation and control capability is enabled.
CLW-Series components are available in white, black, and almond and are designed for use with Decora
®
style faceplates (not included). A dual purpose LED is included to verify preset storage. and serve as a beacon to make the dimmer easy to locate in the dark. Its connection to the control system allows the functions of the CLW-DIM to be controlled from touchpanels, keypads, wireless remotes, and computers to support unlimited flexibility for remote control and integration with other devices and system
infiNET™ Wireless
A wide variety of wireless dimmers and switches are available, making infiNET a perfect choice for locations where physical wiring is difficult or expensive. Connection to a control system allows the functions of the wireless dimmers and switches to be controlled and support unlimited flexibility for remote control and integration with other devices and systems.
Doc. 5999F 31
Residential Lighting Design Guide User Interfaces
Wall Mount Touchpanels
TPS Series Isys
®
Available in 12”(TPS-12L), 15”(TPS-15L) and 17”(TPS-17L) widescreen
24-Bit Isys graphics | 1280 x 768 resolution
DNav dynamic menu objects
Full-motion video with gamma correction
Interactive annotation capability
Built-in biamplified speaker system and microphone
Backlit hard key pushbuttons
QuickMedia® and Crestron Home CAT5 AV connectivity
High-speed Ethernet and Cresnet® communications
Available in black or white
TPS Isys
®
G-Series with Crestron Home or QuickMedia
®
Available in 15”(TPS-15G-(QM or CH)-L) and 17”(TPS-17G-(QM or
CH)-L) widescreen
24-Bit Isys graphics | 1024 x 768 resolution
DNav dynamic menu objects
Dual-window full-motion video, HDTV and RGB display
Interactive annotation capability
Built-in biamplified speaker system and microphone
QuickMedia AV connectivity | audience presentation output
High-speed Ethernet and Cresnet communications
Backlit hard key pushbuttons
Available in black or white
TPMC Isys I/O with Crestron Home or
QuickMedia
®
12" active matrix touchscreen display
24-bit Isys graphics | 800 x 600 resolution
DNav dynamic menu objects
Full-motion video with gamma correction
Interactive annotation capability
Windows XP Embedded operating system
Onboard PC applications for Web browsing, streaming media, and remote access
Multi-format streaming video and audio
Direct panel-to-panel intercom over IP
Built-in amplified speakers and microphone
QuickMedia and Crestron Home CAT5 AV connectivity
High speed Ethernet and Cresnet communications
Available in black or white
Doc. 5999F 32
User Interfaces Residential Lighting Design Guide
TPS-4000L
10.4" active matrix touchscreen display
Isys® graphics engine with 640 x 480 resolution
High performance video with gamma correction
Built-in amplified speakers and microphone
5 engravable hardbuttons | Built-in light sensor
Stylish flush mount design | Optional rack mount
Cresnet® communications
TPMC-8L
8.4" active matrix touchscreen display
16-bit Isys i/O graphics with 800 x 600 resolution
DNav dynamic menu objects
Windows XP Embedded operating system
Onboard PC applications for Web browsing, streaming media, conferencing, VoIP, remote computer access
Multi-format streaming video and audio | WAV file audio feedback
Built-in stereo speakers and dual microphones
Includes faceplate with 16 hard key pushbuttons
Button engraving available as solid or backlit text No-button blank faceplate also provided
Built-in biometric fingerprint scanner and light sensor
10/100 fast Ethernet communications | Rear panel USB ports
Available in almond, black, white, or stainless steel
TPS-4L
3.6" active matrix color touchscreen display
16-bit Isys graphics | 320 x 240 resolution
Synapse Image Rendering Algorithm
10 white backlit pushbuttons and engravable faceplate
WAV file audio feedback
Ethernet and Cresnet communications
10 designer colors: Almond, Black, Butter, Cream, Ecru, Smoke,
Stone, White, and Wheat
Doc. 5999F 33
Residential Lighting Design Guide
Tilt Touchpanels
User Interfaces
TPS Series Isys
®
Available in 12"(TPS-12L), 15"(TPS-15L) and 17"(TPS-17L) widescreen
24-bit Isys graphics | 1280 x 768 resolution
DNav dynamic menu objects
Full-motion video with gamma correction
Interactive annotation capability
Built-in biamplified speaker system and microphone
Backlit hard key pushbuttons
QuickMedia® and Crestron Home CAT5 AV connectivity
High-speed Ethernet and Cresnet® communications
Available in black or white
TPS Isys G-Series with Crestron Home or
QuickMedia
Available in 15"(TPS-15G-(QM or CH)-L) and 17"(TPS-17G-(QM or
CH)-L) widescreen
24-Bit Isys graphics | 1024 x 768 resolution
DNav dynamic menu objects
Dual-window full-motion video, HDTV and RGB display
Interactive annotation capability
Built-in biamplified speaker system and microphone
QuickMedia AV connectivity | audience presentation output
High-speed Ethernet and Cresnet communications
Backlit hard key pushbuttons
Available in black or white
TPMC Isys i/O with Crestron Home or
QuickMedia
12" active matrix touchscreen display
24-Bit Isys graphics | 800 x 600 resolution
DNav dynamic menu objects
Full-motion video with gamma correction
Interactive annotation capability
Windows XP Embedded operating system
Onboard PC applications for Web browsing, streaming media, and remote computer access
Multi-format streaming video and audio
Direct panel-to-panel intercom over IP
WAV file audio feedback
Built-in amplified speakers and microphone
QuickMedia* and Crestron Home CAT5 AV connectivity
High-speed Ethernet and Cresnet communications
Available in black or white
TPS-4000
10.4" active matrix touchscreen display
Isys graphics engine with 640 x 480 resolution
High performance video with gamma correction
Built-in amplified speakers and microphone
5 engravable hardbuttons | Built-in light sensor
Stylish flush mount design | Optional rack mount
Cresnet communications
Doc. 5999F 34
User Interfaces Residential Lighting Design Guide
TPMC Series Isys i/O WiFi Touchpanels
TPMC-8T
8.4" active matrix touchscreen display
16-bit Isys i/O graphics | 800 x 600 resolution
Synapse image rendering algorithm
DNav dynamic menu objects
Windows XP Embedded operating system
Onboard PC applications for Web browsing, streaming media, conferencing, VoIP, and remote computer access
Streaming video from network cameras and servers
Built-in microphone and stereo speakers
5-way thumbpad and 4 hard key buttons
Includes stylus with onboard storage slot
Built-in biometric fingerprint scanner
Built-in Bluetooth technology
Wired 10/100 Ethernet and 802.11a/b/g Wi-Fi communications
TPMC-8X
Stylish and compact ergonomic design
8.4"active matrix touchscreen display
16-bit Isys i/O graphics | 800 x 600 resolution
Synapse image rendering algorithm
DNav dynamic menu objects
802.11a/b/g Wi-Fi 2-way wireless communications
Windows XP Embedded operating system
Onboard PC applications for Web browsing, streaming media, conferencing, VoIP, and remote computer access
Wireless video from network cameras and servers
Built-in microphone and stereo speakers
5-way thumbpad and 4 hard key buttons
Includes stylus with onboard storage slot
Built-in biometric fingerprint scanner
Built-in Bluetooth technology
Internal Li-Ion battery pack included
External booster battery pack available
Optional desktop and wall mount docking stations
TPMC-4XG
Stylish and ergonomic handheld design
3.5" active matrix touchscreen display | 240 x 320 resolution
16-bit Isys i/O graphics | Synapse image rendering algorithm
Backlit hard buttons, thumbpad, and scroll wheel
Microsoft Windows CE .NET operating system
Windows SideShow-enabled
Wireless video from network cameras and servers
802.11b/g Wi-Fi 2-way wireless communications
Includes stylus with onboard storage slot
Includes docking station and Li-Ion battery pack
Doc. 5999F 35
Residential Lighting Design Guide User Interfaces
Wireless Touchpanels and Handhelds
TPS-6X
Elegant high gloss black or white, or matte black finishes
Non-slip rubber grips on rear
Illuminated buttons and engravable backlit text
5.7" active matrix color touchscreen display
16-bit Isys® graphics | 640 x 480 resolution
Dynamic graphics and text capability
Synapse Image Rendering Algorithm
Windows SideShow-enabled
Displays full-motion video while docked
High-power, high-speed 2.4 GHz RF wireless technology
Up to 200 feet RF range indoors
1-way IR wireless capability also built in
Includes tabletop tilt docking station, interface module, and NiMH rechargeable battery pack
Wired Ethernet, Cresnet®, and Crestron Home CAT5 video connectivity
Doc. 5999F
MT-1000C
Stylish and ergonomic handheld design
3.8" active-matrix color touchscreen
320 x 240 resolution | 16-bit Isys graphics
Synapse Image Rendering Algorithm
Backlit pushbuttons and 5-way thumbpad
WAV file audio feedback
Auto-shutoff and pick-up sensor
1-way RF or IR wireless communication
Programmable using Crestron VTPro-e software
Includes docking station and Li-Ion battery pack
ML-600
Ergonomic handheld design
Large programmable LCD screen flanked by 10 menu buttons
3 LCD menu navigation buttons
27 programmable function buttons
2 programmable power buttons
5-way thumb pad for OSM navigation
EL backlighting of LCD screen and buttons
1-way RF or IR wireless communication
Operates on 4 AAA alkaline batteries
WPR-48
Waterproof handheld remote
Configurable for 9, 18, 27, or 48 function
Multi-function buttons allow single-press, 2-position or
3-position rocker action
Customizable labeling
Electroluminescent backlighting
1-way RF or IR wireless communication
Long-life lithium rechargeable batteries
Includes docking station/charger and lanyard
36
User Interfaces
Keypads
Residential Lighting Design Guide
C2N-DB Series Decorator Keypads
Crestron C2N-DB Decorator Series keypads deliver versatile keypad control with contemporary styling to support a broad range of residential and commercial applications from lighting to AV distribution.
Available in configurations of 6, 8, or 12 buttons, Decorator keypads are designed to allow installation in perfect harmony with non-Crestron devices using readily available Decora® style faceplates (not included). Mountable in a standard electrical gang box, multiple keypads can easily be ganged sideby-side along with other wall mount devices. All button caps are engravable and include integral red LED light pipe feedback indicators.
Features
Fits standard electrical gang boxes and Decora® faceplates
Available in 6, 8, and 12 button configurations
Replaceable, custom-engravable button caps
Programmable feedback LEDs
Available in black, white, and almond
Easy Cresnet® wiring
C2N-DB Mounting
Doc. 5999F 37
Residential Lighting Design Guide User Interfaces
CNX Designer Series Keypads
The CNX-B Designer series wall mount keypads are available in configurations of 2, 4, 6, 8, or 12 buttons. Buttons are large for optimal ergonomics. Each model mounts in a standard electrical gang box and includes a matching 1-gang faceplate. Optional 2 and 3-gang faceplates are available to allow up to three keypads to be installed side-by-side. Optional
Designer and Architectural faceplates are offered in a variety of elegant finishes. Button caps are engravable and include LED feedback indicators. Standard models are available in White,
Black or Almond. Backlit button caps are also available (black only).
CNX-B series keypads include built-in WAV sound file capability to enable customized audible feedback. An onboard temperature sensor is also included for general monitoring of room temperature. The product name corresponds to the number of keypad buttons. For example,
CNX-B6 is a six-button keypad and a CNX-B12 is a 12-button keypad.
The CNX-B series keypads have a uniquely stylish shape and faceplates are available for the most common groupings; single, double, or three gang plate arrangements.
Features
Available with 2, 4, 6, 8, or 12 buttons
Colors include white, almond, or black
Metal faceplate options:
- Black Chrome - Brushed Gold
- Polished Black - Polished Gold
- Polished Brass - Stainless Steel
Primed faceplate available
All keypads can be custom engraved.
All keypad buttons are backlit capable and have an LED that serves as a user feedback indicator. Status LEDs are controlled via SIMPL programming or the
Crestron D3 Pro software. The illumination of each LED is independently addressable and programmable. Each LED can be programmed to dim at night and return to full intensity during the day
Each keypad requires 3 watts of power
Crestron keypads can be ganged in one, two or three gang configurations and are mounted in standard electrical junction boxes. Custom multi-gang plates are required.
Mounting in Single-Gang Box
Doc. 5999F 38
User Interfaces
Cameo™
Residential Lighting Design Guide
Doc. 5999F
Crestron Cameo presents a fresh, innovative concept in keypad design featuring an incredibly small footprint and slim profile with versatile button configurations.
Cameo Standard Mount
The C2N-CBD-TS is a standard mount model designed for installation in a conventional electrical gang-box using a Decora® style faceplate (not included).
New smooth and textured finishes match perfectly with popular off-the-shelf decorator faceplates. Available in a variety of designer colors, the smooth finish has a slick, glossy appearance, while the textured finish achieves a softer, satiny look.
Cameo Flush Mount
The Cameo unique flush mount design affords a very discreet appearance occupying just one-third the space of a conventional keypad. Employing a smart spring clamp mounting system, the C2N-CBF-T Cameo Flush Mount model installs easily in drywall without requiring a backbox. Five designer colors are available, each with a satiny, textured finish.
Customizable Buttons
Exquisitely simple yet highly customizable, a single Cameo keypad can be configured easily by the installer to provide from two to six buttons. Each keypad is actually furnished with an assortment of engravable button caps in three different sizes to support a variety of physical layouts. Their smoothly rounded shape and refined pushbutton action give each button press a positive feel with subtle surface relief for an excellent tactile response. Through programming, each button can be configured to support up to three separate functions simply by tapping, double-tapping, or holding the button. "Shift key" functionality is even possible, allowing any button to be held while pressing another. The button caps feature an ergonomically tapered shape for excellent tactile response. The taper of each button can be oriented upward or downward, enabling two vertically adjacent buttons to emulate the feel of a single rocker switch.
Auto-dimming Backlight
Cameo's new high-quality backlit laser engraving provides customizable button text that's easy to read under any lighting condition. A built-in light sensor controls the backlight intensity automatically to achieve a crisp, legible appearance in both darkened and fully lit rooms.
Enhanced LED Feedback
Six pinhead-sized white LED light pipes provide elegant and versatile button feedback. Ten different blink patterns are built in, enabling blinking LED feedback while simplifying programming and minimizing traffic on the Cresnet® network.
Built-in bargraph logic allows the feedback LEDs to function as a 6-segment bar graph display to provide a visible level indication when adjusting lighting and audio settings. The overall LED intensity is auto-dimmable, adjusting automatically for optimal visibility under varying lighting conditions.
Contact Closure Inputs
Two sensing inputs are included on the rear of the keypad to provide a simple and convenient interface for low voltage contact-closure devices such as occupancy sensors, door switches, and motion detectors.
Ambient Light Sensor
In addition to controlling Cameo's backlight and LED intensity, the built-in light sensor can also be utilized by the control system to support daylight harvesting and other programmatic functions.
Available Colors and Textures
Black, White, Almond. Brown, Ivory, Brown, Dark Almond, and Dusk in smooth and textured versions.
39
Residential Lighting Design Guide
Cameo ™ Mounting Options
User Interfaces
Cameo Flush Mount
Using the supplied template, carefully cut the hole for the Cameo keypad. After the keypad is connected to Cresnet®, insert it in the hole.
The spring clip holds the keypad in place.
Cameo Standard Mount
Standard mount keypads fit in a standard single-gang box.
Finish the installation with a Decora® style faceplate.
Mud Ring Mount Kit
The Mud Ring Mount Kit (MMK-CBF-T) is the preferred mounting option for the Crestron C2N-CB Series of Cameo keypads when cutouts in the drywall (for the flush-mount keypad installation) are too large. This kit provides support for additional plastering that can be applied to hide irregularities in the cutout.
NOTE: This mounting option is intended for flush-mount keypads only.
Do not use the C2N-CB with the decorator-style keypads.
NOTE: A Crestron module in Crestron Database version 17.1.0, the C2N-
Cameo Bargraph Feedback v1.0, makes it possible to use the feedback
LEDs like a bar graph, for a function such as volume control, where the switches are used to control the volume, the LEDs display its level.
Doc. 5999F 40
iLux Integrated Lighting Control System Residential Lighting Design Guide
iLux Integrated Lighting Control System
NOTE: CLW-series dimmers are compatible with CLS-C6,
CLS-C6M, CLSI-C6, and CLSI-C6M. iLux is a complete, integrated lighting system designed for wall mount installation in boardrooms, auditoriums, theaters, or anywhere versatile and cost-effective control of lighting and shades is required. The Crestron reputation for innovation and reliability, combined with high quality integrated dimming, native shade control, configurable rocker buttons, extensive integration ability and many other advanced features make iLux the ideal choice for all types of room lighting and shade control applications. iLux is compliant with ASHRAE Standard 90.1-2004- Energy
Standard for Buildings, and specifically the Mandatory Provisions
9.4.1.1 (b) and (c) regarding the use of an occupant sensor that turns the lights off within 30 minutes after leaving the space, and a control system that indicates that an area is unoccupied. iLux also complies with Provision 9.4.1.4, which pertains to the control of display, accent, task and demonstration lighting.
Six channels of dimming are available for incandescent, magnetic low-voltage, neon/cold cathode, and 2-wire dimmable fluorescent loads. Control of on/off switching of many nondimmable lighting loads is also possible. Each channel will handle up to 800 watts individually, with a total rating of 1920
(1920 watts when fed from a 20A circuit breaker, 1440 watts when fed from a 15A circuit breaker watts for the complete unit).
Larger loads and additional load types can also be supported using add-on lighting expansion modules (sold separately).
Using the Crestron networked Shade and Drape Controllers (sold separately), the iLux devices enables versatile control of a roomful of motorized window treatments, screens and lifts in up to six shade groups. Shade and drape control does not use a lighting control channel.
Doc. 5999F 41
Residential Lighting Design Guide
iLux Features
iLux Integrated Lighting Control System
Wireless iLux Remote
The CLS-IRHT8 is a compact IR wireless remote designed specifically for use with
Crestron iLux Integrated Lighting Systems. The CLS-IRHT8 provides buttons for master up/down control, plus activation of scenes 1-4, ON, and OFF. The CLS-IRHT8 is non-programmable, and operates on two AA batteries (included).
Doc. 5999F 42
iLux Integrated Lighting Control System Residential Lighting Design Guide
One CLS-C6 master will support up to eight additional CLS-C6 (or CLS-C6M) units, enabling systems of up to 54 lighting zones and 54 shade groups. Commands for typical functions like scene recall, scene off, master dimming, and occupancy status are shared between the CLS-C6 units. Each individual unit can still support a complete assortment of local devices including keypads, shade controllers, and motion detectors.
NOTE: Shade groups are independent of lighting control zones.
Stand-alone Master with Slave wiring Control system as master with slave wiring
Doc. 5999F 43
Residential Lighting Design Guide iLux Integrated Lighting Control System
Control System Integration
The CLS-C6 features two separate Cresnet® control networks, one for local devices and one for connection to a 2-Series control system.
Connecting the CLS-C6 to a control system allows its functions to be controlled from touchpanels, keypads, RF wireless remotes, and even computers.
The control system interface also enables extensive flexibility for integration with other systems such as security, HVAC and energy management, plus remote monitoring via SNMP and Crestron RoomView® applications.
NOTES: Dimmed outputs are not used to directly control outlets or other devices like projectors or AC motor loads. Connecting more than three devices (keypads or shade control modules) will require additional power supplies .
Doc. 5999F 44
iLux Integrated Lighting Control System Residential Lighting Design Guide
iLux Expansion Modules
All expansion modules are compatible with Crestron CLX-Series, CLW-Series, iLux, and infiNET™ in-wall dimmers.
Model Load Function
CLS-EXP-DIM
CLS-EXP-DIMU
CLS-EXP-DIMFLV
CLS-EXP-DIMFDB
Supports incandescent, magnetic low voltage, neon/cold cathode, and 2-wire and 3-wire dimmable fluorescent loads (16A per load)
120V, 230V, & 277V compatibility
Supports incandescent, magnetic low voltage,
Electronic low voltage, and 2-wire and 3-wire dimmable fluorescent loads (16A per load)
120V, 230V, & 277V compatibility
Supports 4-wire Fluorescent, Incandescent, MLV and
ELV loads (16A per load)
120V, 230V, & 277V compatibility
Supports 3-wire Fluorescent
UL2043 rated for use in air handling spaces.
Crestron CLS-EXP-DIM expansion modules are the only units on the market that are code compliant for installation in air handling spaces. Mounting these in the ceiling can save significant wiring costs on your projects.
Forward Phase Dimming
Forward and Reverse-Phase Dimming
Auto Load Type Detection
0-10V Fluorescent Dimming plus High
Inrush Switching
Fluorescent Dimming
NOTES: Refer to the wiring diagrams for expansion module connection details.
Each expansion module can control 120VAC /230/277 loads.
Up to four expansion modules of the same type can be controlled in a single zone.
Refer to the Crestron website for additional iLux example diagrams.
Doc. 5999F 45
Residential Lighting Design Guide iLux Integrated Lighting Control System
Expansion Modules Wiring Diagrams
NOTE: 230V feed is available on CLSI units only
Doc. 5999F 46
iLux Integrated Lighting Control System Residential Lighting Design Guide
Wall Box Dimmers and Switches
Although the following devices are functional as a standalone dimmer or switch, they deliver greatly enhanced functionality as part of a complete Crestron control solution. Designed to replace any standard in-wall dimmer or light switch, when connected to a Crestron
PAC2 or PAC2M automation control system (or any other
2-Series control system) via the Cresnet® network, extensive automation and control capability is enabled.
Underwriters Laboratories (UL) safety regulations require an air gap between the contacts. Building on this requirement, Crestron has expanded the wall box dimmer and switch products to include many new features.
CLW-Series components are available in white, black, and almond and are designed for use with Decora® style faceplates (not included). A dual purpose LED is included to verify preset storage and serve as a beacon to make the dimmer easy to locate in the dark. Its connection to the control system allows the functions of the CLW-DIM to be controlled from touchpanels, keypads, wireless remotes, and computers to support unlimited flexibility for remote control and integration with other devices and systems.
Doc. 5999F 47
Wall Box Dimmers and Switches
Cresnet Wall Box Dimmers
Model Load Features
CLW-DIM
Wall Box Dimmer
(Stand-alone)
CLW-DIM1
Wall Box Dimmer,
Single Button
(Stand-alone)
Supports incandescent loads up to 1000 watts, or magnetic low voltage loads up to 1000VA/750 Watts
Supports incandescent loads up to 1000 Watts, or magnetic low voltage loads up to 1000VA/750 Watts
Four possible dimming level presets. The slide switch selects between ADJUST, PRESET, and
OFF modes
Two possible dimming level presets. The slide switch selects between ADJUST, PRESET, and
OFF modes
CLW-DIMS
Wall Box Master
Dimmer
(Master)
Supports incandescent loads up to 1000 Watts, or magnetic low voltage loads up to 1000VA/750 Watts
Four possible dimming level presets. The slide switch selects between ADJUST, PRESET, and
OFF modes. Serves as the master for multipoint dimming control of a single load. Multipoint dimming (similar to 3-way or 4-way switching) is enabled using one CLW-DIMS with one or more CLW-SLVD Slave Dimmers.
NOTE: In multipoint systems, only the master unit is connected to Cresnet. Slave units are connected by the120V (Traveler) wire.
CLW-SLVD
Wall Box Slave
Dimmer
(Slave)
CLW-DIMS1
Wall Box Master
Dimmer, Single
Button
(Master)
Supports incandescent loads up to 1000 watts, or magnetic low voltage loads up to 1000VA/750 watts
Supports incandescent loads up to 1000 Watts, or magnetic low voltage loads up to 1000VA/750 watts
One-gang wall mount slave dimmer designed for use with the CLW-DIMS Wall Box Master
Dimmer to provide multi-point dimming control of a single load.
The three pushbuttons on the CLW-SLVD provide parallel functionality to those on the
CLW-DIMS
Serves as the master for multi-point dimming control of a single load. Multi-point dimming
(similar to 3-way or 4-way switching) is enabled using one CLW-DIMS1 with one or more CLW-SLVD1 Slave Dimmers
Two possible dimming level presets. The slide switch selects between ADJUST, PRESET, and
OFF modes
CLW-SLVD1
Wall Box Slave
Dimmer, Single
Button
Supports incandescent loads up to 1000 watts, or magnetic low voltage loads up to 1000VA/750 watts
One-gang wall mount slave dimmer designed for use with the CLW-DIMS1 Wall Box Master
Dimmer to provide mult-point dimming control of a single load
(Slave)
The single pushbutton on the CLW-SLVD1 provides parallel functionality to that on the
CLW-DIMS1
NOTE : In Multigang installation the inner tabs must be removed to fit and the load capacity must be derated. See table below for derating information for various applications.
Derating Information for Incandescent and Tungsten Halogen Applications
Part Number No Side Removed One Side Removed Two sides removed
-DIM1 1000W 600W
-DIMS1 1000W 600W
-SLVD1 No Derating Necessary
Derating Information for Magnetic Low Voltage Applications
Part Number No Side Removed One Side Removed
400W
400W
Two sides removed
-DIMS1
-SLVD1
750W 400VA/300W
1000VA/750W 600VA/450W 400VA/300W
No Derating Necessary
Doc. 5999F 48
Wall Box Dimmers and Switches Residential Lighting Design Guide
Cresnet Wall Box Switches
Model Load Features
CLW-SW
Wall Box
Switch
(Stand-alone)
CLW-SW1
Wall Box
Switch, Single
Button
(Stand-alone)
CLW-SWS1
Wall Box
Master Switch,
Single Button
(Master)
Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low-voltage and neon/cold cathode loads up to 1000VA/750 watts.
Fluorescent ballasts, highintensity discharge lighting, and ceiling fans can also be switched.
Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low voltage and neon/cold cathode loads up to 1000VA/750 watts.
Fluorescent ballasts, highintensity discharge lighting, and ceiling fans can also be switched.
Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low voltage and neon/cold cathode loads up to 1000VA/750 watts.
Fluorescent ballasts, highintensity discharge lighting, and ceiling fans can also be switched
Large button provides instant on/off control of the load, while the small button turns the load off following a preset time delay. The slide switch selects between ADJUST,
PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.
NOTE: The wall box switches do not support fan speed control. Use the CLX-1FAN4 for fan speed control.
Provides instant turn-on control of the load. Pressing the button again turns the load off following a preset time delay. The time delay can be overridden by tapping the button a second time, turning the load off instantly. The slide switch on the CLW-SW1 selects ADJUST, PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.
Multiple units may be ganged side-by-side along with other CLW-Series switches and dimmers or non-Crestron devices. The single large button on the CLW-SWS1 provides instant turn-on control of the load. Pressing the button again turns the load off following a preset time delay. The time delay can be overridden by tapping the button a second time, turning the load off instantly. The slide switch on the CLW-SWS1 selects ADJUST, PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.
One-gang wall mount slave switch designed for use with the CLW-SWS1 Wall Box Master Switch to provide multipoint switching control of a single load. The single pushbutton on the CLW-SLVS1 provides parallel functionality to that on the CLW-SWS1.
CLW-SLVS1
Wall Box Slave
Switch, Single
Button
(Slave)
CLW-SWS
Wall Box
Master Switch
(Master)
Supports incandescent and electronic low voltage loads up to 1000 watts, or magnetic low-voltage and neon/cold cathode loads up to 1000VA/750 watts.
1000 watt electronic light switch designed to mount in a standard electrical gang box
Serves as the master for multipoint switching control of a single load. Multi-point switching functionality (similar to
3-way or 4-way switching) is enabled by using the CLW-
SWS with one or more CLW-SLVS Slave Switches. The large button on the CLW-SWS allows for instant on/off control of the load, the small button turns the load off following a preset time delay. The slide switch selects between ADJUST, PRESET, and OFF modes. PRESET mode is the normal operating mode, and ADJUST mode is used for setting the delay time.
NOTE: The wall box switches do not support fan speed
control. Use the CLX-1FAN4 for fan speed control.
CLW-SLVS
Wall Box Slave
Switch
(Multipoint
Slave)
1000-Watt electronic light switch designed to mount in a standard electrical gang box
One-gang wall mount slave switch designed for use with the CLW-SWS Wall Box Master Switch to provide multipoint switching control of a single load. The pushbuttons on the CLW-SLVS provide parallel functionality to those on the CLW-SWS.
NOTE: In systems, only the master unit is connected to Cresnet®. Slave units are connected by the120V
(Traveler) wire.
Doc. 5999F 49
Guide infiNET Wireless Technology
infiNET™ Wireless Technology
Doc. 5999F 50
Guide infiNET Wireless Technology infiNET Dimmers, Switches, and Thermostat
Model Load Function
CLW-DIM1RF infiNET Wall Box
Dimmer
CLW-DIM4RF infiNET Wall Box
Dimmer and
Keypad
CLW-DIMS1RF infiNET Wall Box
Master Dimmer
1000-watt wall mount dimmer
1000-watt wall mount dimmer and programmable keypad
1000-Watt wall mount dimmer
The single large rocker button provides access to three user presets. With each selection, the lighting levels fade naturally between each preset level. Pressing and holding the rocker button up or down allows manual adjustment of the lighting level.
All four pushbuttons are software programmable for any Crestron system function, enabling control over additional lighting circuits, fans, drapes, audio levels, etc.
CLW DIMS4RF infiNET Wall Box
Master Dimmer and Keypad
1000-watt wall mount dimmer and programmable keypad
Multipoint dimming is enabled using one CLW-DIMS1RF master dimmer along with one or more CLW-SLVD1RF slave dimmers. Multipoint dimming is similar to conventional 3-way or 4-way switching, allowing dimming control of a single load from multiple locations in the room.
Multi-point dimming is enabled using one CLW-DIMS4RF master dimmer along with one or more CLW-SLVD1RF slave dimmers. Multipoint dimming is similar to conventional 3-way or 4-way switching, allowing dimming control of a single load from multiple locations in the room. All four pushbuttons are software programmable for any Crestron system function, enabling control over additional lighting circuits, fans, drapes, audio levels, etc.
Slave dimmer designed for use with the CLW-DIMS1RF and CLW-DIMS4RF infiNET master dimmers.
CLW-SLVD1RF infiNET Wall Box
Slave Dimmer
CLW-SW1RF infiNET Wall Box
Switch
CLW-SWS1RF infiNET Wall Box
Master Switch
CLW-SW4RF infiNET Wall Box
Switch and
Keypad
CLW-SWS4RF infiNET Wall Box
Master Switch and Keypad
CLW-SLVS1RF infiNET Wall Box
Slave Switch
CLF-DIMRFB infiNET Lamp
Dimmer
HTT-B10X infiNET Table
Top Controller
1000-watt wall mount slave dimmer
1000-watt wall mount switch
1000-watt wall mount switch
1000-watt wall mount switch and programmable keypad
1000-watt wall mount switch and programmable keypad
1000-watt wall mount slave switch
500 watts V/A
Dimmer
The single large rocker button provides simple on/off operation to control a range of lighting or fan loads. An adjustable turn-off delay allows the user time to exit the room before the lights shut off.
Multi-point switching is enabled using one CLW-SWS1RF master switch along with one or more CLW-SLVS1RF slave switches. Multipoint switching is similar to conventional 3-way or 4-way switching, allowing control of a single load from multiple locations in the room.
An adjustable turn-off delay allows the user time to exit the room before the lights shut off. All four pushbuttons are software programmable for any Crestron system function, enabling control of additional lighting circuits, fans, drapes, audio levels, etc.
All four pushbuttons are software programmable for any Crestron system function, enabling control of additional lighting circuits, fans, drapes, audio levels, etc. Multipoint switching is enabled using one CLW-SWS4RF master switch along with one or more CLW-SLVS1RF slave switches. Multipoint switching is similar to conventional 3-way or 4-way switching, allowing control of a single load from multiple locations in the room.
Slave switch designed for use with the CLW-SWS1RF and CLW-SWS4RF infiNET master dimmers.
Freestanding dimmer module designed to sit on the floor to provide dimming control of a conventional floor lamp or table lamp. It enables local dimming control via a built-in footswitch, and remote control via infiNET.
The HTT-B10X is a simple, convenient wireless controller. Two-way infiNET wireless operation supports true-feedback. A clean array of 10 backlit pushbuttons with individual feedback LEDs affords easy, tactile control of any custom function. The HTT-B10X is a fully-programmable controller designed to operate as part of a complete Crestron automation system, communicating via the infiNET wireless control network.
CHV-TSTATRF
Wireless
Networked
Thermostat
The CHV-TSTATRF is designed for heating and cooling control of baseboard, forced air, heat pump, and dual-fuel heat pump HVAC systems. The large backlit LCD display provides a clear view of current temperature, setpoint, system mode, fan status, and setup functions. Climate control features include separate heating and cooling setpoints, and adjustable anticipators to prevent overshooting the desired temperature. Continuous fan operation can be selected when needed for increased circulation.
Doc. 5999F 51
Control Processors
Example infiNET system
Crestron Residential Lighting Design Guide
Doc. 5999F 52
Residential Lighting Design Guide Control Processors
Control Processors
PAC2 Lighting Control Processor
The PAC2 enables efficient control of lighting and other systems such as HVAC and security, and has been specifically designed for the Crestron automation enclosure and the Crestron lighting system (although other Crestron processors can also be used).
The PAC2 occupies one module space in single-width enclosures and two module spaces in double-width enclosures.
NOTE: Crestron recommends that the control processor be mounted within a separate CAEN enclosure to create a simplified low voltage wiring center.
Cresnet ® Distribution
The built-in Cresnet Hub/Repeater serves as a repeater, splitter, and wiring block. The hub allows for 252 or more devices (touchpanels, keypads, etc.); 32 per segment (A-
H) and distribution up to 3000 feet of Cresnet cable run per segment. There are eight independent segments, each with four Cresnet connectors wired in parallel.
In addition, there is a master NET port on the bottom panel. The eight NET (A-H) activity LEDs illuminate when a device on the respective segment transmits data. When powered by the internal power supply, a maximum of 50 watts (DC) is available for all connected network devices.
The LEDs indicate communication on the Cresnet link.
Memory Expansion
The on-board 36MB memory is enhanced with a 4GB expansion slot that supports off-the-shelf Type II compact flash memory and the IBM Microdrive
hard disk drive, for on-board storage of program and touchpanel files, room and equipment profiles, upgrades, databases, and schedules. Memory is non-volatile to protect against power loss.
Ethernet and e-Control ® 2
The unique Crestron dual bus system, with its high speed
I/O bus architecture, provides blazing fast throughput, system wide. The two 40Mb/s Y-BUS expansion slots offer the option of installing any of the CNX-series cards and all C2-series control cards listed in the Crestron
Product Catalog. The 300Mb/s Z-BUS expansion slot is designed for super high speed control card applications such as 10/100 Ethernet, available via the Crestron single-port C2ENET-1 or dual-port C2ENET-2 cards.
The PAC2 also provides true secure network communications, which is required for today's corporate networks, automated residence systems, and the Internet.
The Dual Port 10/100BaseT Ethernet card (C2ENET-2) supports dynamic and static IP addressing and full duplex
TCP/IP and UDP/IP. It offers a WAN port for Internet and remote-location communications and a LAN port for local in-home or in-office use. A built-in firewall delivers network security with the Network Address Translator
(NAT) and router functions. The built-in Web server uses memory storage on a compact flash card for remote access and control.
Backup and Override
The PAC2 provides external connections for both a backup processor and emergency override closure signals. In the absence of Cresnet, a signal is generated to switch power and communication of the Cresnet system to the back-up processor. When the override connection receives a contact closure, a signal is passed to the lighting modules via the fifth wire of the module interconnect cable, and the lights are turned on to a programmed preset emergency level. They remain at this level until that contact closure is removed.
The Backup Net Input connector allows a backup control system to automatically take control of the Cresnet network in the unlikely event of an internal processor failure. The exclusive, built-in Cresnet watchdog switches over when the CPU fails.
Doc. 5999F 53
Control Processors Crestron Residential Lighting Design Guide
The Fault connector provides a dry contact closure fault signal to notify an external control system when the PAC2 has a system fault. This output is connected to a digital input of the backup computer. A fault is defined as the
CPU not interacting with Cresnet® for 10 seconds. The watchdog switches back if the backup computer is inactive for 10 seconds.
The PAC2 offers eight programmable analog and digital inputs as well as digital outputs. There are eight normally open relays, isolated with MOV suppression.
PAC2 Power Management & Requirements
When power requirements exceed 50 watts, additional power supplies may be added. For example, each keypad in the CNX-B series uses 3 watts, therefore only 15 keypads (allowing for a margin of safety) can be connected without adding an additional power supply.
To ensure sufficient power to accommodate all the
Cresnet devices (keypads, touchpanels, shade/drape controllers, thermostats, sensors, and other interfaces) and to include voltage drops and wire runs, Crestron recommends the CLX-PWS75 75-watt Cresnet power supply module, or the C2N-SPWS300 300-watt system power supply.
The 75-watt power supply is designed to mount in a CAEN
Automation Enclosure. A single CLX-PWS75 can be installed in any single-width enclosure, or up to two may be installed side-by-side in a double-width enclosure. Four (4) Cresnet power ports are provided on the CLX-PWS75, which may be used to supply power directly to Cresnet devices, or connect to the external power input ports of a PAC2 or PAC2M.
100 to 240 VAC, 4A (maximum) and a noise rating less than 150mV. The C2N-SPWS300 provides regulated 24
VDC, 300-watts to Cresnet system components. The C2N-
SPWS300 is capable of delivering a nominal 75 watts of power at 24 volts DC on any of its eight channels.
The CLX-PWS75 is a 75 watt Cresnet Power Supply
Module designed to mount in a CAEN Automation
Enclosure. A single CLX-PWS75 can be installed in any single-width enclosure, or up to two may be installed side-by-side in a double-width enclosure. Four (4) Cresnet power ports are provided on the CLX-PWS75, which may be used to supply power directly to Cresnet devices, or connect to the external power input ports of a PAC2 or
PAC2M.
Additional power supplies should not be mounted on
CAEN-UMP plates in an enclosure that contains dimmer units because this introduces low voltage in the high voltage section of the enclosure. If required, an extra power supply, attached to a CAEN-UMP plate, can be added to a separate CAEN enclosure.
Mounting the PAC2 in a double-wide enclosure
If the power needed for a hub segment exceeds the power available from the internal supply (50 watts, maximum), remove the jumper from the supplied 3-pin mini connector to disconnect the internal power supply, then connect the 24VDC and ground wires from an external source (Crestron 24 VDC - regulated power supply) to the
EXT and G pins.
The 300-watt power supply, specifically designed for large Cresnet control systems, operates with an input of
Refer to the PAC2 Operations Guide (Doc. 5941) for more detailed information.
Doc. 5999F 54
Crestron Residential Lighting Design Guide Control Processors
PAC2M Professional Automation Mini Control System
Modular Enclosure or Wall Mount Installation
The PAC2M is designed to install in a CAEN automation enclosure and provide a direct bus to a cabinet full of CLX-
Series lighting control modules. The PAC2M can also be mounted directly to a suitable surface without an enclosure where allowed.
NOTE: A separate supplemental power supply is required for the PAC2M. It is recommended that power fed to the PAC2M processor comes from a clean and uninterrupted source.
Ethernet and e-Control ® 2
Built-in 10/100 Ethernet facilitates secure high speed network connectivity, enabling extensive capabilities for remote system maintenance and control, and providing an interface to other Crestron control systems. Native features include a built-in email client to report system troubles and other functions to a homeowner or maintenance/service company via instant email notification. An onboard Web server provides the foundation for the exclusive Crestron e-Control 2 XPanel technology, providing secure IP-based remote control using any Windows computer or
CE/PocketPC™ PDA device.
RoomView ® and SNMP
The PAC2M is a compact, low-cost alternative to the
PAC2 designed for small lighting and automation applications. At half the size of a PAC2, the PAC2M is perfect for apartments and smaller homes as well as individual meeting rooms and MDU applications.
2-Series Control System
Built upon the reliable Crestron 2-Series control engine, the PAC2M is extensively programmable using the
Crestron suite of powerful development software and vast database of drivers and software modules. The
PAC2M works seamlessly with the entire Crestron line of lighting dimmers and shade controls, keypads and touchpanels, thermostats, wireless gateways, and expansion modules.
Whole House Integration
The PAC2M provides for the integration of non-Crestron devices and subsystems through a host of control interfaces. Four isolated relays and four digital input ports are built in to accommodate motion sensors, contactors, door strikes, and other low-voltage controls.
Additional relays, I/O ports, serial COM ports, DTMF interfaces, and shade controllers can be added using
Crestron expansion modules at any location throughout a residence or commercial facility.
For large facilities utilizing multiple PAC2M and other control systems, the exclusive Crestron RoomView Help Desk software delivers a comprehensive solution for remote monitoring and asset management. Also, built-in SNMP support enables similar capability using third-party network management software, allowing full control and monitoring from the IT Help Desk or NOC in a format that's familiar to IT personnel.
Cresnet ® Distribution
Cresnet is the communications backbone for Crestron lighting modules, wall box dimmers, thermostats, keypads, and many other devices. This flexible 4-wire bus streamlines the wiring of a complete Crestron lighting system. The PAC2M provides connectivity for numerous Cresnet devices on multiple homeruns via 8 separate Cresnet ports. Its built-in Cresnet hub provides two isolated segments, each supporting 3000 feet of cabling and approximately 25 Cresnet devices. The
Cresnet ports are arranged into two separate power groups providing a clean, flexible 24 Volt DC power distribution solution. An external power supply is required (sold separately).
Doc. 5999F 55
Residential Lighting Design Guide Control Processors
Override
An override input is provided to allow an external contact closure to bypass the PAC2M and activate a preset override state in each connected lighting module. A signal is passed to the lighting modules via the fifth wire of the interconnect cable, and the lights are turned on to a programmed preset emergency level.
Memory Expansion
A memory card slot allows for easy expansion of the PAC2M's internal memory using any
MMC-compatible memory card up to 1 GB.
Double Width Enclosure Mounting
Module and associated terminal block installed in double width enclosure. The PAC2M processor occupies the lowest module position in either the single or double enclosure.
For additional information, refer to the PAC2M
Operations Manual, Doc. 6507.
Doc. 5999F 56
Residential Lighting Design Guide Basic Lighting System Interconnections
Basic Lighting System Interconnections
An example of a Crestron Lighting System that includes thermostat, shade control and interfaces
Doc. 5999F 57
Residential Lighting Design Guide Occupancy and Photocell Sensors
Occupancy and Photocell Sensors
GLS-ODT & GLS-OIR
Model
GLS-OD T-C-500
GLS-ODT-C-1000
GLS-ODT-C-2000
GLS-ODT-W-1200
GLS-OIR-C-450
GLS-OIR-C-1500
GLS-OIR-W-2500
GLS-LOL & GLS-LCL
Green Light Occupancy Sensors
Crestron Green Light™ sensors deliver a powerful and cost-effective solution for reducing energy costs and enhancing the functionality of lighting and environmental systems. Crestron offers ceiling and wall mount occupancy sensors for areas up to 2500 square feet.
Advanced self-adaptive motion sensing using a combination of ultrasonic and passive infrared technologies affords extreme reliability for control of lighting, climate control and other devices in the room. A built-in photocell can be set to override the occupancy sensor if the ambient light level is above a set threshold, preventing lights from turning on when there is sufficient daylight in the room.
Sensors are easily connected to the lighting control processor via the Cresnet control network using a GLS-SIM Sensor
Integration Module. Alternately, they may be connected directly via a digital input port. Please refer to the product specification sheet for complete information.
Mount Type Coverage Area Coverage Pattern
Ceiling
Ceiling
Ceiling
Wall
Ceiling
Ceiling
Wall
500 sq ft
1000 sq ft
2000 sq ft
1200 sq ft
450 sq ft
1500 sq ft
2500 sq ft
180 degrees
360 degrees
360 degrees
110 degrees
360 degrees
360 degrees
110 degrees
Green Light Photocell Light Sensors
Crestron Photocell Light Sensors are designed for daylight harvesting applications to control the balance of natural and artificial lighting in an indoor space. By harnessing natural daylight from windows and skylights, electrical lighting can be turned off or dimmed, reducing energy usage while maintaining a consistent light level for a more efficient and comfortable work space. Outdoor lighting may also be turn off and on automatically using a photocell light sensor.
Please refer to the product specification sheet for complete information.
Model
GLS-LCL
GLS-LOL
Field of View
60 degree cone
60 degree cone
Light Sensitivity
0 to 70 foot candles
3 to 6000 foot candles
Doc. 5999F 58
Residential Lighting Design Guide Integrated Shade and Drape Controllers
Integrated Shade and Drape Controllers
C2N-SDC
The C2N-SDC is a 2-channel shade and drape controller designed to provide a convenient and cost-effective solution for controlling a variety of motorized window treatments as well as motorized doors, sunroofs, lifts and projection screens.
The C2N-SDC is a Cresnet® device with two independently controlled 120V AC outputs.
Each output provides up/down or open/close control of a conventional 3-wire bidirectional type motor. Built-in timing and interlock logic make it easy to program the C2N-SDC for fail-safe operation.
The C2N-SDC mounts in the wall or ceiling using an off-the-shelf 4" square or 2-gang electrical box. Pushbuttons on the front of the unit allow for manual operation of the motors during installation and setup.
C2N-SDC-DC
The C2N-SDC-DC is a 2-channel shade and drape controller designed to provide a convenient and cost-effective solution for controlling 24 volt DC motorized shades and drapes. The C2N-SDC-DC is a Cresnet device with two independently controlled 24V DC outputs, each designed to provide standard up/down or open/close control of a conventional two-wire bidirectional type motor.
The C2N-SDC-DC mounts in the wall or ceiling using an off-the-shelf 4" square or
2-gang electrical box. Pushbuttons on the front of the unit allow for manual operation of the motors during installation and setup.
C2N-SSC-2
Doc. 5999F
The C2N-SSC-2 Somfy Shade Controller is a compact Cresnet device designed to provide a bidirectional serial interface for up to two Somfy ILT Intelligent Shade Motors
(http://www.somfy.com/nam/index.cfm). Window treatments equipped with the Somfy
ILT motor offer enhanced capability compared to typical 3-wire models.
In addition to basic open/close commands, the C2N-SSC-2 allows for setting each shade to a specific position and polling for its current position with 16-bit precision.
Feedback signals provide confirmation of each motor's activity to enable precise, predictable control, even from a remote location. Limit adjustments are set electronically using buttons provided on the face of the unit, and up to 20 presets for each output can be saved onboard the C2N-SSC-2 for easy recall through the control system. The C2N-SSC-2 mounts discreetly to any flat surface and requires a simple
Cresnet connection to the control system.
59
Residential Lighting Design Guide Integrated Partner Modules
Integrated Partner Modules
Crestron Electronics, Inc. Integrated Partner Program allows partner manufacturers' products to operate seamlessly in a Crestron systems environment. Integrated Partner Modules offer the Crestron control systems programmer a simplified, timesaving drag-and-drop solution for integration of partner products.
The Crestron Integrated Partner Program initiative makes it easy to take advantage of the enhanced functionality afforded by using a manufacturer's serial, Ethernet, or other enhanced interface. Integrated
Partner Modules are created specifically for popular audio/video, security, lighting, HVAC and other products that incorporate communications protocol, relays, etc. We have created this collection of modules for our dealers to easily incorporate Integrated Partner's products into a Crestron network solution .
For a complete list of partners refer to: http://www.crestron.com/tools_and_resources/programming_and_integr ation_resources/integrated_partner_modules/default.asp?browseby=ma nufacturers
Integrated Systems
Following are examples of the more common systems we integrate into both commercial and residential environments.
Audio/Video Lighting Systems
Integrated Partner business or home entertainment solutions allow you to easily control and enjoy your business presentations, home theater or audio distribution systems. Want to make a presentation, watch a movie? Press the appropriate icon and the drapes close, lights dim, projector turns on, audio engages and the experience begins... all while the popcorn pops.
Integrated Partner lighting systems work seamlessly in a
Crestron environment.
Depending on your lighting system you may enjoy party mode to brighten up the house for your guests, integrate it into
“movie” mode, or set the system to "vacation" mode, for random lighting patterns giving your home that live-in look while you’re away.
HVAC
Integrated Partner heating and air-conditioning systems, pools and spas may also be incorporated into a Crestron system.
Set the temperature and humidity range you most enjoy and live comfortably, regardless of the season.
Security
Integrated Partner security companies trust Crestron to control and monitor their systems.
Peace of mind is a touch away. Whether setting your system before retiring for the evening or receiving an e-mail that your family forgot to set the system before leaving for the day, Crestron-controlled security partners are there for your protection.
Doc. 5999F 60
Residential Lighting Design Guide Appendix A
Appendix A: Example Residential Lighting
System
This example is based on the following typical residential wiring plan.
Doc. 5999F 61
Residential Lighting Design Guide
Load Schedule Report Example
Appendix A
Load Schedule
Project: Example Residence
Creator: Crestron D3 Pro v2.3.7
Date: 11/4/2003 System Number: 1
Dealer: Crestron
Description:
Area Room Controlled Ckt Name Controlled Ckt No. Fixture Load Type Dim Emergency Fixture Watts Fixture Qty Total Watts
Main Floor Bathroom 1
Main Floor Bathroom 1
Main Floor Bathroom 1
Main Floor Bathroom 1
Main Floor Bathroom 1
Main Floor Bathroom 2
Main Floor Bathroom 2
Main Floor Bathroom 2
Main Floor Bathroom 2
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Main Floor Bedroom
Main Floor Foyer
Main Floor Sauna
Downlights
Downlights 2
Downlights 3
Drapes
Exhaust Fan
Downlights
Downlights 2
Drapes
Exhaust Fan
Ceiling Fan
Downlights
Downlights 2
Downlights 3
Downlights 4
Downlights 5
Drapes
Drapes 2
Drapes 3
Downlights
Drapes
009 Downlights Incandescent yes
008 Downlights Incandescent yes
006 Downlights Incandescent yes
019 Drapes 3-Wire Motor no
007
011
Exhaust Fan Switched no
Downlights Incandescent yes
010 Downlights Incandescent yes
021 Drapes 3-Wire Motor no
012 Exhaust Fan Switched no
022
005
004
Ceiling Fan Ceiling Fan no
Downlights Incandescent yes
Downlights Incandescent yes
003
002
001
018
017
016
013
020 no 100 1 100 no 100 2 200 no 100 2 200 no no no
200
200
100
1
1
1
200
200
100 no 100 3 300 no 200 1 200 no 200 1 200 no 100 1 100 no 250 2 500 no 100 4 400
Downlights Incandescent yes
Downlights Incandescent yes
Downlights Incandescent yes
Drapes 3-Wire Motor no
Drapes 3-Wire Motor no
Drapes 3-Wire Motor no no 100 1 100 no no 100 2 200 no no no
100
200
200
200
1
1
1
1
100
200
200
200
Downlights Incandescent yes no 100 4 400
Drapes 3-Wire Motor no no 200 1 200
*Calculation of load wattage includes transformer loss.
Appendix A
Project: Example Residence
Creator: Crestron D3 Pro v2.3.7
Date: 11/4/2003 System Number: 1
Load Schedule with Panel Terminations
Dealer: Crestron
Description:
Area
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Main
Floor
Room
Controlled Ckt
Name
Controlled
Ckt No. Fixture Load Type Dim Emergency
Fixture
Watts
Fixture
Qty
Total
Watts Enclosure Slot Module Output
Bathroom
1
Bathroom
1
Bathroom
1
Downlights 2
Downlights 3
008
006
Downlights
Downlights Incandescent
Downlights Incandescent yes yes yes no no
100
100
2
2
200
200
Enclosure 1
Enclosure 1
2
2
1DIM8
CLX-
1DIM8
CLX-
1DIM8
Bathroom
1
Bathroom
1
Bedroom
Bedroom
Drapes
Exhaust Fan
Downlights 4
Downlights 5
019
007
002
001
Drapes
Exhaust Fan
3-Wire Motor
Switched
Downlights Incandescent
Downlights Incandescent no no yes yes no no no no
200
200
100
100
1
1
1
2
200
200
100
200
Enclosure 1
N / A
4 CLX-
1MC4
N / A Interface
2
Enclosure 1 2 CLX-
1DIM8
Bathroom
2
Bathroom
2
Downlights
Downlights 2
011
010
Downlights Incandescent
Downlights Incandescent yes yes no no
100
100
1
3
100
300 Enclosure 1 2
Bathroom
2
Bathroom
2
Bedroom
Drapes
Exhaust Fan
Ceiling Fan
021
012
022
Drapes
Exhaust Fan
Ceiling Fan
3-Wire Motor
Switched
Ceiling Fan no no no no no no
200
200
100
1
1
1
200
200
100
Enclosure 1
N / A
4 CLX-
1MC4
N / A Interface
4
Enclosure 1 6 CLX-
1FAN4
Bedroom Downlights 005 Downlights yes no 250 2 500 2 CLX-
1DIM8
Bedroom Downlights 2 004 Downlights Incandescent yes no 100 4 400 Enclosure 1 3 CLX-
1DIM4
Bedroom Downlights Incandescent yes no 100 1 100
CLX-
1DIM8
N / A
N / A
N / A Interface
6
N / A Interface
5
Enclosure 1 3 CLX-
1DIM4
1
2
3
1
1
4
5
2
1
1
7
1
1
1
2
Bedroom Drapes 018 Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 4 CLX-
1MC4
3
Bedroom
Bedroom
Drapes 2
Drapes 3
017
016
Drapes
Drapes
3-Wire Motor
3-Wire Motor no no no no
200
200
1
1
200
200
Enclosure 1
Enclosure 1
4
5
CLX-
1MC4
CLX-
1MC4
4
1
Foyer Downlights 013 Downlights yes no 100 4 400 2 CLX-
1DIM8
Sauna Drapes 020 Drapes 3-Wire Motor no no 200 1
6
200 Enclosure 1 5 CLX-
1MC4
2
*Calculation of load wattage includes transformer loss.
The following three pages contain the complete application diagrams of this example system, Circuits and Interfaces, Module Wiring, and PAC2 Connections, divided up to fit the space available. The complete diagram is available on line at: http://www.crestron.com/dealer-tech_resources/application_diagrams.asp
.
Doc. 5999F 63
Residential Lighting Design Guide
Circuits and Interfaces
Appendix A
Module Wiring
Appendix A
Doc. 5999F 65
Residential Lighting Design Guide
PAC2 Lighting Control Processor Connections
Appendix A
Residential Lighting Design Guide Appendix B
Appendix B: Touchpanel Comparison Charts
Tilt Touchpanels
Touchscreen Display
Display Size
Aspect Ratio
TPS-17B
(TPS-17W)
17"
15:9
WXGA
Isys Tilt Touchpanels
TPS-15B
(TPS-15W)
15"
TPS-12B
(TPS-12W)
12"
Isys G-Series
TPS-4000 TPS-3000 TPS-15G-
QM
10.4" 6.4" 15"
TPS-12G-
QM
12"
4:3 XGA 4:3 SVGA 4:3 VGA 4:3 VGA 4:3 XGA 4:3 SVGA
Isys i/O Tilt Touchpanel Media Centers
TPMC-17-QM TPMC-15-QM TPMC-17-CH TPMC-15-CH
17" 15" 17" 15"
15:9 WXGA 4:3 XGA 15:9 WXGA 4:3 XGA
Resolution
Color Depth
Touchpanel Graphics
Color Depth
8-bit Alpha Channel
Transparency
Synapse Image Rendering and Multimode Objects
Dynamic Text and Animation
Dynamic Graphics and PNG
Translucency
Dynamic Menu Graphics
1280 x 768
24-bit
16.7M
24-bit
16.7M
●
●
●
●
1024 x 768
24-bit
16.7M
24-bit
16.7M
●
●
●
●
800 x 600
18-bit
16.7M
24-bit
16.7M
●
●
●
●
640 x 480
18-bit
256k
16-bit 64k
●
●
640 x 480
18-bit
256k
16-bit 64k
●
●
1024 x
768
24-bit
16.7M
24-bit
16.7M
●
●
●
●
800 x 600
18-bit 256k
18-bit 256k
●
●
●
●
1280 x 768
24-bit 16.7M
24-bit 16.7M
●
●
●
●
●
1024 x 768
24-bit 16.7M
24-bit 16.7M
●
●
●
●
●
1280 x 768
24-bit 16.7M
24-bit 16.7M
●
●
●
●
●
1024 x 768
24-bit 16.7M
24-bit 16.7M
●
●
●
●
●
Memory
RAM
128MB 128MB 128MB 8MB 8MB
Flash 64MB 64MB 64MB
Memory Card Slot
Maximum Project Size up to 4GB
160MB up to 4GB up to 4GB up to 4GB up to 4GB
Annotation & PC
Windows XP Embedded OS
Embedded Applications and
Viewers
4
Annotation
Keyboard/Mouse Input
Touch-the-PC
Live Only
USB
Mouse
●
Live Only
USB Mouse
●
Video/RGB
Scalable Windows
Hardware Connections
Composite
S-Video
Component
HDTV up to 1080i
RGB up to 1600 x 1200
Streaming Motion-JPEG
Media Player (Multiple
Formats)
Display Output
Audio
Amplified Speakers and
Microphone
WAV Sound File Audio
Feedback
Network
Cresnet
Ethernet
WiFi
1
QM, CH,
BNC
1
●
●
●
●
●
●
●
1
QM, CH,
BNC
1
●
●
●
●
●
●
●
1
QM, CH,
BNC
1
●
●
●
●
●
●
●
Buttons
Backlit Softkeys 4 4
1
Connections via outboard IMC interface module (included)
2
Wireless NIC required
3
Accessory sold separately
4
Refer to the product specification for a complete list of embedded applications
4
1
CH
1
,
BNC
1
●
●
●
●
●
1
CH
1
,
BNC
1
●
●
●
●
●
2
QM QM QM QM
1
BNC
1
●
●
●
●
●
●
●
●
●
●
4
2
●
●
●
●
●
●
●
●
●
●
4
512MB
512MB up to 4GB up to 4GB up to 4GB up to 4GB
●
●
MediaMarker MediaMarker
USB USB USB USB
●
2
●
●
●
●
●
●
●
●
●
●
●
●
●
4
512MB
512MB
●
●
●
2
●
●
●
●
●
●
●
●
●
●
●
●
●
4
512MB
512MB
●
●
MediaMarker
2
●
●
●
●
●
●
●
●
4
●
●
●
●
512MB
512MB
●
●
MediaMarker
2
●
●
●
●
●
●
●
●
●
●
●
●
4
Doc. 5999F 67
Residential Lighting Design Guide Appendix B
Wall Mount Touchpanels
Audio
Amplified Speakers and
Microphone
WAV Sound File Audio
Feedback
Network
Cresnet
Ethernet
●
●
●
●
●
●
●
●
Isys Wall Mount Touchpanels
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Isys G Series
●
●
●
●
●
●
●
Isys i/O Media Centers
Touchscreen Display
Display Size
Aspect Ratio
Resolution
Color Depth
Touchpanel Graphics
Color Depth
8-bit Alpha Channel
Transparency
Synapse Image Rendering and Multimode Objects
Dynamic Text and
Animation
Dynamic Graphics and
PNG Translucency
Dynamic Menu Objects
TPS-17L
24-bit
16.7M
●
●
●
TPS-15L
24-bit
16.7M
●
●
●
TPS-12L
●
●
TPS-
4000L
●
●
TPS-6L TPS-4L
24-bit
16.7M
16-bit 64K 16-bit 64K 16-bit 64K
●
●
●
TPS-15G-
QM-L
24-bit
16.7M
●
●
●
TPS-12G-
QM-L
24-bit
16.7M
●
●
●
TPMC-
17-QM-L
17" 15" 12" 10.4" 5.7” 3.6" 15" 12" 17"
15:9
WXGA
4:3 XGA 4:3 SVGA 4:3 VGA 4:3 SVGA 4:3 QVGA 4:3 XGA 4:3 SVGA
15:9
WXGA
1280 x
768
1024 x 768
24-bit
16.7M
800 x 600 640 x 480 640 x 480 320 x 240
1024 x
24-bit
16.7M
18-bit 256k 18-bit 256k
18-bit
256k
16-bit 64k
768
24-bit
16.7M
800 x 600
18-bit
256k
1280 x
768
24-bit
16.7M
24-bit
16.7M
●
●
●
TPMC-15-
QM-L
15"
4:3 XGA
1024 x 768
24-bit
16.7M
24-bit
16.7M
●
●
●
TPMC-17-
CH-L
17"
15:9 WXGA
1280 x 768
24-bit
16.7M
24-bit
16.7M
●
●
●
TPMC-15-
CH-L
15"
4:3 XGA
1024 x 768
24-bit
16.7M
24-bit
16.7M
●
●
●
Media Player (Multiple
Formats)
Display Output
● ● ● ● ●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Memory
RAM
Flash
Memory Card Slot
128MB
64MB up to 4GB
128MB 128MB 8MB
64MB 64MB 8MB up to 4GB up to 4GB
32MB
32MB
16MB
8MB
128MB
64MB up to 4GB
160MB
128MB
64MB up to 4GB
512MB
512MB up to
4GB
190MB
512MB
512MB up to 4GB
512MB
512MB up to 4GB
512MB
512MB up to 4GB
Maximum Project Size
Annotation & PC
160MB 160MB 160MB 7MB 28MB 7MB 160MB 190MB 190MB 190MB
Windows XP Embedded
OS
6
● ● ● ●
Annotation
Keyboard/Mouse Input
Live Only Live Only
Media
Marker
USB
Media
Marker
USB
Media
Marker
USB
Media
Marker
USB Touch-the-PC
Video/RGB
Scalable Windows
Hardware Connections
1 1 1 1 1 2 2 2 2 2 2
CH, BNC QM QM QM QM CH, BNC
1
CH, BNC
1
Composite
S-Video
Component
HDTV up to 1080i
QM, CH,
BNC
1
●
●
●
QM, CH,
BNC
1
●
●
●
QM, CH,
BNC
1
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
RGB up to 1600 x 1200
Streaming Motion-JPEG
● ●
●
●
●
●
●
●
●
●
●
●
● ●
●
●
●
●
●
●
●
●
●
●
●
●
Wi-Fi
3
Buttons
Backlit Softkeys
Programmable, Engravable
Hard Buttons
Finishes
White or Black
Almond
4
●
4
●
Additional Colors &
Finishes
1 Connections via outboard IMC interface module (included)
2 Also supports coaxial connection
3 Wireless NIC required
4 Appropriate mounting accessory(ies) required
5 Rack mount provided by others
6 See product specification for a complete list of embedded applications
4
● ●
●
●
●
●
●
●
●
4
●
4
●
4
●
4
●
4
●
4
●
Doc. 5999F 68
Crestron Residential Lighting Design Guide Appendix B
Wireless Touchpanels & Handheld Remotes
Display
Display Type
Display Size
Resolution
Color Depth
Buttons & Controls
Programmable Hard
Buttons
Thumb Pad
3-Way Toggle Wheel
Biometric Fingerprint
Scanner
Button Backlighting
Custom Engravable
Touchpanel Graphics
Color Depth
Synapse Image Rendering
Multimode Objects
True Feedback, Dynamic
Text, & Animation
Dynamic Graphics & PNG
Translucency
DNav Dynamic Menu
Objects
Memory
Ram
Flash
Memory Card Slot
Maximum Project Size
Embedded PC
Operating System
Embedded Applications
1
Keyboard/Mouse Input
Video
Wired via Docking Station
Streaming via Media Player
Streaming MJPEG
Audio
Integrated Speakers &
Microphone
WAV Sound File Audio
Feedback
Network
2-Way High-Powered RF via CEN-HPRFGW
2-Way Wi-Fi RF via 3rdparty 802.11x WAP
2-Way infiNET
TM
EX RF via
CEN-RFGW-EX
1-Way RF 418 MHz via
CNRFGWA-418 or MC2W
1-Way RF 434 MHz via
CNRFGWA or MC2W
1-Way IR 38 kHz RC5 via
C2N-IRGW or CNXRMIRD
1-Way IR 455 kHz via
CN-TVAV
Wired Ethernet via Docking
Station
Wired Cresnet via Docking
Station
Batteries
Internal Rechargable
External Booster Option
Disposable
Docking Station
Desktop
Wall Mount
●
●
●
●
●
●
2
Isys Wireless
TPS-6X
TFT Active Matrix
Color
Touchscreen
5.7"
18-bit 262k
Colors
17 or 2
●
●
●
16-bit 64k
●
●
●
●
TFT Active Matrix
Color
Touchscreen
8.4"
640 x 480 VGA 800 x 600 SVGA
18-bit 262k
Colors
TFT Active Matrix
Color
Touchscreen
8.4"
800 x 600 SVGA
18-bit 262k
Colors
11 11
21
●
●
16-bit 64k
●
●
●
●
●
●
●
16-bit 64k
●
●
●
●
●
TFT Active Matrix
Color
Touchscreen
TFT Active
Matrix
Color
Touchscreen
3.5" 3.8"
240 x 320 QVGA
(portrait)
16-bit 64k Colors
320 x 240
QVGA
16-bit 64k
Colors
●
●
16-bit 64k
●
●
●
●
●
14
●
●
16-bit 64k
●
32MB
Backlit LCD
1.5" W
102 x 120
7 lines
Monochrome
47
●
●
512MB 512MB 64MB 16MB
32MB
28MB
●
1GB 1GB 32MB up to 4GB up to 4GB
190MB 190MB 12MB 16MB
Windows XP
Embedded
Windows XP
Embedded
Windows CE
.NET 4.2
● ●
USB USB
●
●
●
●
●
●
●
● ● ●
●
802.11a/b/g 802.11a/b/g
802.11b
●
●
●
●
●
●
●
2
●
2
●
Integrated
●
●
●
●
AAA (x4)
1
Refer to product specifications for a complete list of embedded applications
2
Accessory sold separately
Backlit LCD
57
●
●
2.1" H x 1.4" W
7 lines
Monochrome
9 to 48
Label Inlay
Label Inlay
●
●
●
●
●
●
●
●
AAA (x4)
1 to 30
●
9 Volt (x1)
●
Doc. 5999F 69
Residential Lighting Design Guide Appendix C
Appendix C: General Lighting Design
Considerations
Crestron provides many options for illumination control.
The following general lighting design information can help you formulate a complete, energy efficient lighting design plan. required for the dynamic elements, the elements that change in response to environmental and human variables. These static and dynamic elements are fully integrated in a complete lighting design.
Simple Lighting Coverage Areas
Light plays an essential role in our ability to view the world around us, and how we perceive a space it can even influence how we act in that space. Lighting can affect performance, mood, morale, safety, security and decision making.
In some rooms, one lighting fixture or a group of fixtures provide all the illumination. These rooms include closets, storage rooms, utility rooms and garages. In these areas, the functionality of the fixtures outweighs style consideration.
The first step in producing the right lighting design is asking about the use of the space. The lighting designer can then determine quantity of light, color quality, brightness and direction.
The greatest energy efficiency is achieved with compact fluorescent downlights. The best performing systems use a 32 watt "triple tube" downlight, providing more light than a 100 watt incandescent lamp while consuming 1/3 the amount of energy.
There are two aspects of lighting design that go hand in hand: the qualitative or aesthetic aspect, and the quantitative or engineering aspect. The qualitative aspect has to do with ensuring that the space has a pleasing feel and ambiance. It is the artistic interspersing of light and shadow, illumination and darkness, figure and form.
For many spaces, such as garages and closets, a simple lighting solution is the most appropriate. In storage rooms, basements, and other places, basic lighting may be all that is needed. These are excellent opportunities for energy efficient lighting fixtures, especially if lights are left on for extended periods of time.
The quantitative aspect ensures that there is adequate light for the task at hand. The Illuminating Engineering
Society (IES) of North America publishes guidelines of light levels for many tasks and activities based on the nature of the task, the size of objects handled, the detail required, the average age of the people in that space, and so on.
For example, a typical office is lit to an illumination of 30 to 100 "footcandles". Light levels can also be expressed in the metric unit "lux" 1 footcandle is approximately 10 lux.
The rate of energy consumption is called "power" and is measured in watts. A 200 watt lamp is consuming energy at twice the rate of a 100 watt lamp. The electric company charges consumers for the total amount of energy they consume. This is measured in kilowatt-hours or kWh. A 200-watt lamp burning for 5 hours consumes
1,000 watt-hours of energy, which is a kilowatt-hour.
Note that burning a thousand watt lamp for one hour costs the same as burning a hundred watt lamp for ten hours.
Static and Dynamic Elements
Task Lighting for Specific Work
Areas
Task lights minimize reliance on overhead lighting and provide directed lighting for countertop work in kitchens, workshop, office, etc. Energy efficient CFL recessed can lights or reflectorized CFLs are recommended for this application. Recessed downlights are located over task locations, especially in the kitchen, bath, shower, or at a desk. One recessed light may be all that is needed in a shower stall or tub, but in a kitchen, a group of downlights often provides more flexible task lighting. It is best to locate downlights directly over a task, but in the kitchen keep in mind that the downlight must also illuminate into the base cabinets, making fixture locations over the center of the room equally important.
Under-cabinet lights are used whenever there is an overhead cabinet above a counter, such as in a kitchen, laundry room or home office. Fluorescent and LED under-cabinet lights produce significantly more light than incandescent strips, and use much less energy.
The lighting design requires you to define the building envelope, electric lighting, façade features, and other static elements that affect lighting. Window placement and glazing, floor layout, building orientation, and fixture placement are all static elements that define the building space and lighting environment. Crestron control is
Doc. 5999F 70
Residential Lighting Design Guide
Ambient Lighting for Mood and
Highlights
Ambient light is the general, overall light that fills in shadows, reduces contrast, and lights vertical surfaces to give the space a brighter feel. Ambient light is what you need for casual activities in your rooms. Ambient lighting sets a dramatic or subtle mood within a living space. Use ambient lights to illuminate hallways, entryways, artwork and architectural highlights in the home or office. The nature and quality of ambient lighting determines the overall feel of the room. Even if your design produces the right amount of light for each task and display and you have sconces or chandeliers, it is possible that more ambient light is needed. Ambient light is intentionally obscure, and as such it can be difficult to determine when more is necessary. Often the best way to provide ambient light is with hidden fixtures.
Ambient light is a primary concern in the kitchen, where table lamps and floor lamps aren't welcome because they get in the way. Some common ways to introduce ambient light in the kitchen are:
Fluorescent uplights on top of cabinets
Central fluorescent lights on the ceiling
Wall sconces, especially those with uplight
Decorative lights with an open top that place most of the light on the ceiling
Decorative Lighting
Decorative lighting includes chandeliers, sconces, and table lamps, and is usually chosen based on style and appearance. Generally, decorative lights produce only modest amounts of illumination. A lighting design begins with architecture, style and décor. Some things just look right, feel right, and fit well with the overall design of the room. Decorative lighting such as chandeliers, sconces, and table lamps are part of our culture, and they provide at least some portion of the light needed for certain tasks.
As a general rule, designers should choose the decorative lighting that fits the space. Traditional locations include a chandelier over the dining room table, a pendant light over the breakfast table, a lamp on a side table in the living room, or a lantern by the front door. Keep in mind that other lighting may also be needed (to illuminate tasks or displays), but due to the important role that decorative lighting plays, it comes first. Accent lighting gives the space a third dimension, adding to the quality of the space.
Focal Lighting
Focal, or display lighting illuminates art, architecture, collections and other displays. Determine whether you
Doc. 5999F 71
Appendix C want to highlight objects of art, memorabilia, bookcases, or other things that you may wish to have stand out. For many families, the fireplace mantel and the wall above the mantel are primary locations for display items.
As a rule of thumb, mount the focal light 21 inches from the wall with an 8-foot ceiling, 27 inches from the wall with a 9-foot ceiling, 34 inches from the wall with a 10foot ceiling, and so on. One accent light will illuminate anything from a small object (with a 10-15 degree spot lamp) to a painting up to 3 feet wide (with a 35-35 degree flood lamp). Add a second light for every 30-36 inches of width of the object you are lighting.
Key Light
When shining a light on an object from a single point source it is called key light. A key light highlights the contours of an object and creates shadows. The exact effect depends on the angle of the beam of light. Most of the time we want to light the object so we can see its front. In these cases, the light source may be best placed in front of and to the side of the object at an angle of 45°.
Fill Light
A fill light can either be directional or diffused. Shining a directional light on an object from the opposite direction of the key light can soften or eliminate shadows, depending on the strength of the fill light relative to the strength of the key light. Fill light sources can be placed behind objects to light the entire room evenly.
Uplighting
The effect of uplighting is either very desirable or very undesirable because of unusual effects that can range from intimate to eerie. A lot of landscape lighting includes uplighting to accentuate bushes and trees.
Sparkle and Glitter Effects
To add an atmosphere of elegance, add little lighting points of interest in the form of sparkle or glitter. This effect can be produced by either producing sharp reflections on reflective surfaces in the room (sparkle), such as silverware in a restaurant, or by making the light source itself a source of interest (glitter) such as with a chandelier. Avoid glare in these cases by adjusting the angle of the light source.
Residential Lighting Design Guide
Grazing and Washing Surfaces
On walls or on the surface of an object, changing the way light is focused produces different effects. To emphasize a rough textured brick wall, graze the surface with light striking the surface at a sharp angle. To emphasize a smooth wall, wash the surface with light by striking the surface at a wider angle.
Switch and Dimmer Locations
The proper location for a switch or dimmer is a function of code requirements (the National Electrical Code establishes some specific locations where control devices are required) and common sense. For example, the code requires a wall switch adjacent to the door upon entry to a room. but you can also add a switch in a preferred location, such as next to the bed.
Another choice are motion sensors that automatically switch lights off when the room is empty, and they are especially efficient devices in spaces like garages, utility rooms and other spaces where lights are only needed occasionally and are often left on inadvertently.
Crestron offers the most technologically sophisticated products that permit handheld remote dimming, whole house master controls, and many other features.
Color Temperature
Color temperature is the color of the light source. By convention, yellow-red colors (like the flames of a fire) are considered warm, and blue-green colors (like light from an overcast sky) are considered cool. Color temperature is measured in Kelvin (K) temperature. Higher Kelvin temperatures (3600–5500 K) are considered cool and
Appendix C lower Kelvin color temperatures (2700–3000 K) are considered warm. Cool light is preferred for visual tasks because it produces a higher contrast than warm light.
Warm light is preferred for living spaces because it is more flattering to skin tones and clothing. A warm color temperature of 2700–3600 K is generally recommended for most indoor general and task lighting applications.
Color Rendition
Color rendition is the appearance of colors when illuminated by a light source. Color rendition is generally considered to be a more important lighting quality than color temperature. Most objects are not a single color, but a combination of many colors. Light sources that are deficient in certain colors may change the apparent color of an object. The Color Rendition Index (CRI) is a 1–100 scale that measures a light source's ability to render colors the same way sunlight does. The top value of the
CRI scale (100) is based on illumination by a 100 watt incandescent light bulb. A light source with a CRI of 80 or higher is considered acceptable for most indoor residential applications.
Glare
Glare is primarily the result of relative placement of light sources and the objects viewed. Often, it is excessive brightness from a direct light source making it difficult to see. A bright object in front of a dark background usually causes glare. Bright lights reflecting off a television or computer screen or even a printed page produces glare.
Intense light sources—such as bright incandescent lamps—are likely to produce more direct glare than large fluorescent lamps.
Doc. 5999F 72
Residential Lighting Design Guide Appendix D
Appendix D: Glossary of Lighting Terminology
A
AMPERE: The standard unit of measurement for electric current that is equal to one coulomb per second. It defines the quantity of electrons moving past a given point in a circuit during a specific period, abbreviated amp.
ANSI: Abbreviation for American National Standards Institute
ARC TUBE: A tube enclosed by the outer glass envelope of a HID lamp and made of clear quartz or ceramic that contains the arc stream
ASHRAE: American Society of Heating, Refrigerating and Air-Conditioning
Engineers
B
BAFFLE: A single opaque or translucent element used to control light distribution at certain angles
BALLAST: A device used to operate fluorescent and HID lamps. The ballast provides the necessary starting voltage, while limiting and regulating the lamp current during operation
BALLAST CYCLING: Undesirable condition under which the ballast turns lamps on and off (cycles) due to the overheating of the thermal switch inside the ballast. This may be due to incorrect lamps, improper voltage being supplied, high ambient temperature around the fixture, or the early stage of ballast failure
BALLAST EFFICIENCY FACTOR: The ballast efficiency factor (BEF) is the ballast factor (see below) divided by the input power of the ballast. The higher the BEF (within the same lamp-ballast type) the more efficient the ballast.
BALLAST FACTOR: The ballast factor (BF) for a specific lamp-ballast combination represents the percentage of the rated lamp lumens that will be produced by the combination
COLOR TEMPERATURE: The color temperature is a specification of the color appearance of a light source, relating the color to a reference source heated to a particular temperature, measured by the thermal unit
Kelvin. The measurement can also be described as the "warmth" or
"coolness" of a light source. Generally, sources below 3200K are considered "warm;" while those above 4000K are considered "cool" sources
COMPACT FLUORESCENT: A small fluorescent lamp that is often used as an alternative to incandescent lighting. The lamp life is about 10 times longer than incandescent lamps and is 3-4 times more efficacious.
Also called PL, Twin-Tube, CFL, or BIAX lamps
CONSTANT WATTAGE (CW) BALLAST: A premium type of HID ballast in which the primary and secondary coils are isolated. It is considered a high performance, high loss ballast featuring excellent output regulation
CONSTANT WATTAGE AUTOTRANSFORMER (CWA) BALLAST: A popular type of HID ballast in which the primary and secondary coils are electrically connected. Considered an appropriate balance between cost and performance
CONTRAST: The relationship between the luminance of an object and its background
CRI: (SEE COLOR RENDERING INDEX)
CUT-OFF ANGLE: The angle from a fixture's vertical axis at which a reflector, louver, or other shielding device cuts off direct visibility of a lamp. It is the complementary angle of the shielding angle
D
C
CANDELA: Unit of luminous intensity, describing the intensity of a light source in a specific direction
CANDELA DISTRIBUTION: A curve, often on polar coordinates, illustrating the variation of luminous intensity of a lamp or luminaire in a plane through the light center
CANDLEPOWER: A measure of luminous intensity of a light source in a specific direction, measured in candelas (see above)
CBM: Abbreviation for Certified Ballast Manufacturers Association.
CEC: Abbreviation for California Energy Commission
COEFFICIENT OF UTILIZATION: The ratio of lumens from a luminaire received on the work plane to the lumens produced by the lamps alone.
(Also called "CU")
COLOR RENDERING INDEX (CRI): A scale of the effect of a light source on the color appearance of an object compared to its color appearance under a reference light source. Expressed on a scale of 1 to 100, where
100 indicates no color shift. A low CRI rating suggests that the colors of objects will appear unnatural under that particular light source
DALI: Digital Addressable Lighting Interface is a protocol set out in the technical standard IEC 60929. A DALI system is self-contained. A ballast and a multi-sensor, offer benefits such as constant light control, PIR movement-detection and IR remote operation. Multiple DALI systems can be connected together using gateways to building management systems. Software programs offer more sophisticated programming functionality for grouped systems, such as scene setting, time clock, and partition control
DAYLIGHT COMPENSATION: A dimming system controlled by a photocell that reduces the output of the lamps when daylight is present. As daylight levels increase, lamp intensity decreases. An energy-saving technique used in areas with significant daylight contribution
DERATING: Components can be treated in such a way as to enhance their life expectancy. Derating is the name normally given to operating a component well inside its normal operating limits to extend the life of a component, and is a practical means of reducing failures. The National
Electrical Code and local electrical codes determine the amount of available current based on a derating factor. A derating factor improves reliability by reducing the upper limit of current carrying capacity to compensate for electrical, mechanical and thermal stress
DIFFUSE: Term describing dispersed light distribution. Refers to the scattering or softening of light
DIFFUSER: A translucent piece of glass or plastic sheet that shields the light source in a fixture. The light transmitted throughout the diffuser will be redirected and scattered
DIRECT GLARE: Glare produced by a direct view of light sources. Often the result of insufficiently shielded light sources. (See GLARE)
Doc. 5999F 73
Crestron Lighting Software
DOWNLIGHT: A type of ceiling luminaire, usually fully recessed, where most of the light is directed downward. May feature an open reflector and/or shielding device
E
EFFICACY: A metric used to compare light output to energy consumption.
Efficacy is measured in lumens per watt. Efficacy is similar to efficiency, but is expressed in dissimilar units. For example, if a 100-watt source produces 9000 lumens, then the efficacy is 90 lumens per watt
ELECTROLUMINESCENT: A light source technology used in exit signs that provides uniform brightness, long lamp life (approximately eight years), while consuming very little energy (less than one watt per lamp)
ELECTRONIC BALLAST: A ballast that uses semi-conductor components to increase the frequency of fluorescent lamp operation (typically in the
20-40 kHz range. Smaller inductive components provide the lamp current control. Fluorescent system efficiency is increased due to high frequency lamp operation
ELECTRONIC DIMMING BALLAST: A variable output electronic fluorescent ballast
ELECTRONIC LOW-VOLTAGE (ELV): Electronic low-voltage lighting uses an electronic (solid-state technology) transformer to convert line voltage
(120 VAC) to low voltage (typically 12 VAC). This lower voltage is then used power an incandescent low-voltage lamp. Track lights are usually electronic low-voltage
EMI: Abbreviation for electromagnetic interference. EMI is the high frequency interference (electrical noise) caused by electronic components or fluorescent lamps that interferes with the operation of electrical equipment. EMI is measured in micro-volts, and can be controlled by filters. Because EMI can interfere with communication devices, the Federal Communication Commission (FCC) has established limits for EMI
ENERGY-SAVING BALLAST: A type of magnetic ballast designed so that the components operate more efficiently, cooler and longer than”standard magnetic" ballast. By US law, standard magnetic ballasts can no longer be manufactured
ENERGY-SAVING LAMP: A lower wattage lamp, generally producing fewer lumens
F
FC: (SEE FOOTCANDLE)
FLUORESCENT LAMP: A light source consisting of a tube filled with argon, along with krypton or other inert gas. When electrical current is applied, the resulting arc emits ultraviolet radiation that excites the phosphors inside the lamp wall, causing them to radiate visible light
FOOTCANDLE (FC): The English unit of measurement of the illuminance
(or light level) on a surface. One footcandle is equal to one lumen per square foot
FOOTLAMBERT: English unit of luminance. One footlambert is equal to
1/p candelas per square foot.
FORWARD PHASE DIMMING: Rather than attempting to restrict the amplitude of the current flowing through a lamp, as in other forms of dimming, forward phase control works by switching off the beginning part of each cycle of the alternating current supply
Appendix D
FOUR-WIRE 10V ANALOG SIGNAL DIMMING: Two power wires (switched hot and neutral) and two additional control wires that are connected to a low-voltage circuit. Note: these ballasts do not turn on and off like DALI ballasts, so in addition to the low-voltage-level control circuit, they must also have a line-voltage switch. Zero to ten-volt control is a low-voltage
DC dimming method. Power wires are rated Class 1 and control wires are rated Class 2. This separation allows multiple circuits to use the same dimming signal without additional power equipment
G
GLARE: The effect of brightness or differences in brightness within the visual field sufficiently high to cause annoyance, discomfort or loss of visual performance
H
HALOGEN: (SEE TUNGSTEN HALOGEN LAMP)
HARMONIC DISTORTION: A harmonic is a sinusoidal component of a periodic wave having a frequency that is a multiple of the fundamental frequency. Harmonic distortion from lighting equipment can interfere with other appliances and the operation of electric power networks. The total harmonic distortion (THD) is usually expressed as a percentage of the fundamental line current. THD for 4-foot fluorescent ballasts usually range from 20% to 40%. For compact fluorescent ballasts, THD levels greater than 50% are not uncommon
HID: Abbreviation for high intensity discharge. Generic term describing mercury vapor, metal halide, high-pressure sodium, and (informally) low-pressure sodium light sources and luminaires
HIGH BAY: Pertains to the type of lighting in an industrial application where the ceiling is 20 feet or higher. Also describes the application itself
HIGH OUTPUT (HO): A lamp or ballast designed to operate at higher currents (800 mA) and produce more light.
HIGH POWER FACTOR: Ballast with a 0.9 or higher rated power factor, which is achieved by using a capacitor.
HIGH PRESSURE SODIUM LAMP: A high intensity discharge (HID) lamp whose light is produced by radiation from sodium vapor (and mercury)
HOT RESTART or HOT RESTRIKE: The phenomenon of re-striking the arc in an HID light source after a momentary power loss. Hot restart occurs when the arc tube has cooled a sufficient amount
I
IESNA: Abbreviation for Illuminating Engineering Society of North
America.
ILLUMINANCE: A photometric term that quantifies light incident on a surface or plane. Illuminance is commonly called light level. It is expressed as lumens per square foot (footcandles), or lumens per square meter (lux)
INDIRECT GLARE: Glare produced from a reflective surface.
INSTANT START: A fluorescent circuit that ignites the lamp instantly with a very high starting voltage from the ballast. Instant start lamps have single-pin bases
Doc. 5999F 74
Crestron Residential Lighting Design Guide
L
LAMP CURRENT CREST FACTOR (LCCF): The peak lamp current divided by the RMS (average) lamp current. Lamp manufacturers require <1.7 for best lamp life. An LCCF of 1.414 is a perfect sine wave
LAMP LUMEN DEPRECIATION FACTOR (LLDF): A factor that represents the reduction of lumen output over time. The factor is commonly used as a multiplier to the initial lumen rating in illumination calculations, which compensates for the lumen depreciation. The LLD factor is a dimensionless value between 0 and 1
LAY-IN-TROFFER: A fluorescent fixture; usually a 2' x 4' fixture that sets or "lays" into a specific ceiling grid
LED: Abbreviation for light emitting diode. An illumination technology used for exit signs. Consumes low wattage and has a rated life of greater than 80 years
LENS: Transparent or translucent medium that alters the directional characteristics of light passing through it. Usually made of glass or acrylic
LIGHT LOSS FACTOR (LLF): Factors that allow for a lighting system's operation at less than initial conditions. These factors are used to calculate maintained light levels. LLFs are divided into two categories, recoverable and non-recoverable. Examples are lamp lumen depreciation and luminaire surface depreciation
LIFE-CYCLE COST: The total costs associated with purchasing, operating, and maintaining a system over the life of that system
LOUVER: Grid type of optical assembly used to control light distribution from a fixture. Can range from small-cell plastic to the large-cell anodized aluminum louvers used in parabolic fluorescent fixtures
LOW POWER FACTOR: Essentially, an uncorrected ballast power factor of less than 0.9 (SEE NPF)
LOW-PRESSURE SODIUM: A low-pressure discharge lamp in which light is produced by radiation from sodium vapor. Considered a monochromatic light source (most colors are rendered as gray)
LOW-VOLTAGE LAMP: A lamp (typically compact halogen) that provides both intensity and good color rendition. Lamp operates at 12V and requires the use of a transformer. Common lamps are MR11, MR16, and
PAR36
LOW-VOLTAGE SWITCH: A relay (magnetically-operated switch) that allows local and remote control of lights, including centralized time clock or computer control
LUMEN: A unit of light flow, or luminous flux. The lumen rating of a lamp is a measure of the total light output of the lamp
LUMINAIRE: A complete lighting unit consisting of a lamp or lamps, along with the parts designed to distribute the light, hold the lamps, and connect the lamps to a power source. Also called a fixture
LUMINAIRE EFFICIENCY: The ratio of total lumen output of a luminaire and the lumen output of the lamps, expressed as a percentage. For example, if two luminaires use the same lamps, more light will be emitted from the fixture with the higher efficiency.
LUMINANCE: A photometric term that quantifies brightness of a light source or of an illuminated surface that reflects light. It is expressed as footlamberts (English units) or candelas per square meter (Metric units)
Appendix D
LUX (LX): The metric unit of measure for illuminance of a surface. One lux is equal to one lumen per square meter. One lux equals 0.093 footcandles
M
MAINTAINED ILLUMINANCE: Refers to light levels of a space at other than initial or rated conditions. This term considers light loss factors such as lamp lumen depreciation, luminaire dirt depreciation, and room surface dirt depreciation
MAGNETIC LOW-VOLTAGE (MLV): Magnetic low-voltage lighting uses a magnetic (core and coil technology) transformer to convert line voltage
(120 VAC) to low voltage (typically 12 VAC). This lower voltage is then used to power an incandescent low-voltage lamp. Recessed lights are most often magnetic low-voltage. Magnetic low-voltage lights tend to be larger and heavier than electronic low-voltage
MERCURY VAPOR LAMP: A type of high intensity discharge (HID) lamp in which most of the light is produced by radiation from mercury vapor.
Emits a blue-green cast of light. Available in clear and phosphor-coated lamps
METAL HALIDE: A type of high intensity discharge (HID) lamp in which most of the light is produced by radiation of metal halide and mercury vapors in the arc tube. Available in clear and phosphor-coated lamps
MR-16: A low-voltage quartz reflector lamp, only 2" in diameter.
Typically the lamp and reflector is one unit, which directs a sharp, precise beam of light
N
NADIR: A reference direction directly below a luminaire, or "straight down" (0 degree angle
NEMA: Abbreviation for National Electrical Manufacturers Association
NEON/COLD CATHODE: Highly inductive boost transformer for neon/cold cathode lighting
NIST: Abbreviation for National Institute of Standards and Technology
NPF (NORMAL POWER FACTOR): A ballast/lamp combination in which no components (e.g., capacitors) have been added to correct the power factor, making it normal (essentially low, typically 0.5 or 50%)
O
OCCUPANCY SENSOR: Control device that turns lights off after the space becomes unoccupied. May be ultrasonic, infrared or other type
OPTICS: A term referring to the components of a light fixture (such as reflectors, refractors, lenses, louvers) or to the light emitting or lightcontrolling performance of a fixture
P
PAR LAMP: A parabolic aluminized reflector lamp. An incandescent, metal halide, or compact fluorescent lamp used to redirect light from the source using a parabolic reflector. Lamps are available with flood or spot distributions
PAR 36: A PAR lamp that is 36 one-eighths of an inch in diameter with a parabolic shaped reflector (SEE PAR LAMP)
PARABOLIC LUMINAIRE: A popular type of fluorescent fixture that has a louver composed of aluminum baffles curved in a parabolic shape. The
Doc. 5999F 75
Crestron Lighting Software resultant light distribution produced by this shape provides reduced glare, better light control, and is considered to have greater aesthetic appeal
PARACUBE: A metallic coated plastic louver made up of small squares.
Often used to replace the lens in an installed troffer to enhance its appearance. The paracube is visually comfortable, but the luminaire efficiency is lowered. Also used in rooms with computer screens because of their glare-reducing qualities
PHOTOCELL: A light sensing device used to control luminaires and dimmers in response to detected light levels
PHOTOMETRIC REPORT: A photometric report is a set of printed data describing the light distribution, efficiency, and zonal lumen output of a luminaire. This report is generated from laboratory testing
POWER FACTOR: The ratio of the AC Volts x Amps through a device to the AC wattage of the device. A device such as a ballast that measures
120 Volts, 1 Amp, and 60 Watts has a power factor of 50% (Volts x Amps
= 120 VA, therefore 60 Watts/120 VA = 0.5). Some utilities charge customers for low power factor systems
PREHEAT: A type of ballast/lamp circuit that uses a separate starter to heat up a fluorescent lamp before high voltage is applied to start the lamp
Q
QUAD-TUBE LAMP: A compact fluorescent lamp with a double twin tube configuration
R
RADIO FREQUENCY INTERFERENCE (RFI): Interference to the radio frequency band caused by other high frequency equipment or devices in the immediate area. Fluorescent lighting systems generate RFI
RAPID START (RS): The most popular fluorescent lamp/ballast combination used today. This ballast quickly and efficiently preheats lamp cathodes to start the lamp. Uses a "bi-pin" base
ROOM CAVITY RATIO (RCR): A ratio of room dimensions used to quantify how light will interact with room surfaces. A factor used in illuminance calculations
REFLECTANCE: The ratio of light reflected from a surface to the light incident on the surface. Reflectances are often used for lighting calculations. The reflectance of a dark carpet is around 20%, and a clean white wall is roughly 50% to 60%
REFLECTOR: The part of a light fixture that shrouds the lamps and redirects some light emitted from the lamp
REFRACTOR: A device used to redirect the light output from a source, primarily by bending the waves of light.
RECESSED: The term used to describe the doorframe of a troffer where the lens or louver lies above the surface of the ceiling.
REGULATION: The ability of a ballast to hold constant (or nearly constant) the output watts (light output) during fluctuations in the voltage feeding of the ballast. Normally specified as +/- percent change in output compared to +/- percent change in input.
Appendix D
RELAY: A device that switches an electrical load on or off based on small changes in current or voltage. Examples: low voltage relay and solid state relay
RETROFIT: Refers to upgrading a fixture, room, or building by installing new parts or equipment
REVERSE PHASE DIMMING: Rather than attempting to restrict the amplitude of the current flowing through a lamp, as in other forms of dimming, reverse phase control works by switching off the end part of each cycle of the alternating current supply
S
SELF-LUMINOUS EXIT SIGN: An illumination technology using phosphorcoated glass tubes filled with radioactive tritium gas. The exit sign uses no electricity and thus does not need to be hardwired
SEMI-SPECULAR: Term describing the light reflection characteristics of a material. Some light is reflected directionally, with some amount of scatter
SHIELDING ANGLE: The angle measured from the ceiling plane to the line of sight where the bare lamp in a luminaire becomes visible. Higher shielding angles reduce direct glare. It is the complementary angle of the cutoff angle. (See: CUTOFF ANGLE)
SPACING CRITERION: A maximum distance that interior fixtures may be spaced that ensures uniform illumination on the work plane. The luminaire height above the work plane multiplied by the spacing criterion equals the center-to-center luminaire spacing
SPECULAR: Mirrored or polished surface. The angle of reflection is equal to the angle of incidence. This word describes the finish of the material used in some louvers and reflectors
STARTER: A device used with a ballast to start (preheat) fluorescent lamps
STROBOSCOPIC EFFECT: Condition where rotating machinery or other rapidly moving objects appear to be standing still due to the alternating current supplied to light sources. Sometimes called "strobe effect."
T
T12 LAMP: Industry standard for a fluorescent lamp that is 12 oneeighths, one inch in diameter. Other sizes are T10 and T8 lamps
TANDEM WIRING: A wiring option in which a single ballast is shared by two or more luminaires. This reduces labor, materials, and energy costs.
Also called "master-slave" wiring.
THERMAL FACTOR: A factor used in lighting calculations that compensates for the change in light output of a fluorescent lamp due to a change in bulb wall temperature. It is applied when the lamp-ballast combination under consideration is different from that used in the photometric tests.
THREE-WIRE ANALOG POWER DIMMING: Three-wire control is a linevoltage phase-control dimming method. Along with Hot and Neutral, the dimming signal is communicated via a third wire called Dimmed Hot. All three wires are rated Class 1 and can be run within the same conduit.
TRIGGER START: Type of ballast commonly used with 15-watt and 20watt straight fluorescent lamps
TROFFER: The term used to refer to a recessed fluorescent light fixture
(combination of trough and coffer)
Doc. 5999F 76
Crestron Residential Lighting Design Guide
TUNGSTEN HALOGEN LAMP: A gas-filled tungsten filament incandescent lamp with a lamp envelope made of quartz to withstand the high temperature. This lamp contains some halogens (namely iodine, chlorine, bromine, and fluorine), which slow the evaporation of the tungsten. Also, commonly called a quartz lamp
TWIN-TUBE: (SEE COMPACT FLUORESCENT LAMP)
TWO-WIRE ANALOG POWER DIMMING: Two-wire is a line-voltage phasecontrol dimming method. The ballast receives the dimming signal through the Dimmed Hot wire. Intended for small-scale retrofit applications, the two-wire control method is often the easiest way to implement dimming in existing fluorescent fixtures
U
ULTRA VIOLET (UV): Invisible radiation that is shorter in wavelength and higher in frequency than visible violet light (literally beyond the violet light)
UNDERWRITERS' LABORATORIES (UL): An independent organization whose responsibilities include rigorous testing of electrical products.
When products pass these tests, they can be labeled (and advertised) as
"UL listed." UL tests for product safety only
V
VANDAL-RESISTANT: Fixtures with rugged housings, break-resistant type shielding, and tamper-proof screws
VCP: Abbreviation for visual comfort probability. VCP is a rating system for evaluating direct discomfort glare. This method is a subjective evaluation of visual comfort expressed as the percent of occupants of a space who will be bothered by direct glare. VCP allows for several factors: luminaire luminances at different angles of view, luminaire size, room size, luminaire mounting height, illuminance, and room surface reflectivity. VCP tables are often provided as part of photometric reports
VERY HIGH OUTPUT (VHO): A fluorescent lamp that operates at a "very high" current (1500 mA), producing more light output than a "high output" lamp (800 mA) or standard output lamp (430 mA)
VOLT: The standard unit of measurement for electrical potential. It defines the "force" or "pressure" of electricity
VOLTAGE: The difference in electrical potential between two points of an electrical circuit
W
WALLWASHER: Describes luminaires that illuminate vertical surfaces.
WATT (W): The unit for measuring electrical power. It defines the rate of energy consumption by an electrical device when it is in operation. The energy cost of operating an electrical device is calculated as its wattage times the hours of use. In single-phase circuits, it is related to volts and amps by the formula: Volts x Amps x PF = Watts. (Note: For AC circuits,
PF must be included.)
WORK PLANE: The level at which work is done and at which illuminance is specified and measured. For office applications, this is typically a horizontal plane 30 inches above the floor (desk height)
Z
ZENITH: The direction directly above the luminaire
Appendix D
Doc. 5999F 77
Crestron Electronics, Inc.
15 Volvo Drive
Rockleigh, NJ 07647 www.crestron.com
Specifications subject to change without notice
Doc. 5999F
03.09
Advertisement
Key features
- Modular and Scalable Systems
- Wired and Wireless Options
- Centralized and Decentralized Control
- Comprehensive Control Interfaces
- Energy-Efficient Designs
- Integration with Other Systems