Agilent M9393A Challenge the Boundaries of Test Agilent Modular

Agilent M9393A Challenge the Boundaries of Test Agilent Modular
Agilent M9393A
PXIe Performance Vector
Signal Analyzer
Configuration Guide
9 kHz to 8.4 GHz, 14 GHz,
18 GHz or 27 GHz
Challenge the Boundaries of Test
Agilent Modular Products
O VERV IE W
This configuration guide contains information to help you configure your M9393A PXIe performance vector signal analyzer (PXIe
performance VSA) and tailor a system to meet your requirements.
Ta b le of c o n t e n t s Page number
Hardware
A: Select options for M9393A PXIe performance VSA...........................................................................................................................3
B: Add M9300A PXIe frequency reference................................................................................................................................................3
C: Select controller .......................................................................................................................................................................................4
D: Select a chassis & accessories..............................................................................................................................................................6
Physical connection diagram for controllers, chassis & accessories..............................................................................................7
Software
E: Select software for M9393A PXIe performance VSA.........................................................................................................................8
Services
F: Select services: Warranty, calibration, start-up assistance........................................................................................................... 10
Configuration
Single M9383A PXIe performance VSA................................................................................................................................................... 11
Other
Upgrading your system............................................................................................................................................................................... 12
Using an M9393A in a non-Agilent chassis............................................................................................................................................ 12
PC requirements for M9393A control...................................................................................................................................................... 13
Related literature......................................................................................................................................................................................... 13
2
A. Select options for M9393A PXIe performance VSA
Step 1. Start with M9393A PXIe performance VSA base configuration
The M9393A PXIe performance VSA base configuration (occupies 4 slots) includes:
M9308A
M9365A
M9214A
PXIe synthesizer
PXIe downconverter
PXIe IF digitizer
•
•
•
•
•
•
Frequency range 9 kHz - 8.4 GHz
Analysis bandwidth 40 MHz
Memory 128 MSa (512 MB)
One day start up assistance
Modular interconnect cables
Software, example programs and product
information on CD
• Return to Agilent warranty - 3 years
Step 2. Choose a frequency range
M9391A-F08
9 kHz − 8.4 GHz
M9391A-F14
9 kHz − 14 GHz
M9391A-F18
9 kHz − 18 GHz
M9391A-F27
9 kHz − 27 GHz
Included in base configuration
Step 3. Choose an analysis bandwidth
M9393A-B04
40 MHz
M9393A-B10
100 MHz
M9393A-B16
160 MHz
Included in base configuration
Step 4. Choose memory size
M9393A-M01
128 MSa
M9393A-M05
512 MSa
M9393A-M10
1024 MSa
Included in base configuration
Step 5. Add fast switching speed (optional)
Accelerates test throughput and stepped spectrum analysis
M9393A-UNZ
Fast tuning
Step 6. Add pre-amplifier (optional)
Enhances sensitivity to detect low-level signals
M9393A-P08
100 kHz − 8.4 GHz
M9393A-P14
100 kHz − 14 GHz
M9393A-P18
100 kHz − 18 GHz
M9393A-P27
100 kHz − 27 GHz
B. Add M9300A PXIe frequency reference
Step 1. Add an M9300A PXIe frequency reference (occupies 1 slot)
One frequency reference required per chassis to meet data sheet specifications. It can support up to four M9393A PXIe VSAs
M9393A-300
Adds M9300A PXIe frequency
reference
Five 100 MHz outputs
One 10 MHz output
Internal 10 MHz OCXO timebase output
3
C. Select controller (either embedded controller or via PC) 1
Step 1. If selecting an embedded controller, select either M9036A or M9037A 2
M9036A-M04
Mid-performance embedded controller
Intel i5-520E dual-core, 2.4 GHz, 4 thread, 4GB RAM
Select the M9036A for mid-performance, lower cost or
if your application requires XP operating system
M9037A-M04
High-performance embedded controller
Intel i7-4700EQ quad-core processor, 2.4 GHz, 8 thread,
4GB RAM
Select M9037A for the best performance if you have
memory intensive applications, multiple applications
running in parallel, or if a lot of data is sent to the PC
from the PXIe chassis. Features removable SSD drive
for security and x8 connector from front for connection
to second chassis
Step 2. Upgrade from standard memory size (optional)
For M9036A
M9036A-M08
Memory upgrade from 4 GB to 8 GB RAM
M9037A-M08
Memory upgrade from 4 GB to 8 GB RAM
M9037A-M16
Memory upgrade from 4 GB to 16 GB RAM
For M9037A
Step 3. Select an operating system
For M9036A
M9036A-WE3
Microsoft Windows Embedded Standard 7 (32-bit)
M9036A-WE6
Microsoft Windows Embedded Standard 7 (32-bit)
M9037A-WE3
Microsoft Windows Embedded Standard 7 (32-bit)
M9037A-WE6
Microsoft Windows Embedded Standard 7 (32-bit)
For M9037A
1. For list of qualified external controllers, please see Tested Computer List Technical Note literature no. 5990-7632EN. The M9021A is used for both PC
controllers and can only be used in the M9018A chassis.
2. The M9018A 18-slot chassis includes empty space to the left of the 1st functional slot. The embedded controller occupies that empty space and the 1st
functional slot.
4
C. Select controller (either embedded controller or via PC) 1 (continued)
To use your Laptop PC as a controller
M9045B
PCIe ExpressCard adaptor
Y1200B
PCIe cable
M9021A
PCIe cable interface2 : 1 slot
To use your Desktop PC as a controller
M9048A
PCIe desktop adaptor
Y1202A
PCIe cable
M9021A
PCIe cable interface2 : 1 slot
1. For list of qualified external controllers, please see Tested Computer List Technical Note literature no. 5990-7632EN. See physical connections diagram on page 8.
2. The M9021A is used for either PC control option and can only be used with the Agilent M9018A 18-slot chassis.
5
D. Select a chassis and accessories
Step 1. Select a chassis
M9018A
18-slot PXIe chassis
Step 2. Choose enough slot blocker kits and EMC filler panels to fill every open slot
Recommended to achieve data sheet specifications
Y1212A
Slot blocker kit: 5 slots
Y1213A
PXI EMC filler panel kit: 5 slots
Step 3. Choose a rack mount kit (optional)
Y1215A
Rack mount kit for M9018A 18-slot
PXIe chassis
Step 4 Choose an air inlet kit1 (optional)
Recommended for rack mounted systems with less than 1U space below chassis.
Y1214A
Air inlet kit: M9018A 18-slot
chassis1
1. Available in 1-slot, 2-slot or 3-slot options depending on the chassis configuration. For more information, please visit
www.agilent.com/find/m9018a
6
P HY SICAL C ONNEC T IONS
Physical connection diagram for controllers
External laptop PC control ptions
Embedded controller
M9045B PCIe
ExpressCard
adaptor
M9036A
or M9037A
embedded
controller
Y1200B
PCIe cable
M9021A
PXIe cable
interface
M9393A PXIe performance VSA placed
inside the M9018A PXIe chassis
Y1202A
PCIe cable
M9048A PCIe
adapter
External desktop PC control options
7
E. Select software for M9393A PXIe performance VSA
Step 1. Start with M9393A base configuration
The M9393A comes standard with the following software:
• Agilent IO Libraries Suite including Connection Expert 1
• Instrument software, soft front panel, drivers for use with Matlab, LabVIEW, Visual Studio (including VB Net, C#, C/C++), Agilent VEE 2
• Sample waveforms and programming examples
Step 2. Download free Agilent Command Expert software 3 (optional)
FREE software that provides fast and easy instrument control for the PC. Command Expert combines instrument command sets, command
sequences, documentation, syntax checking and command execution in one simple interface. Command Expert helps you to:
• Find instrument commands
• Access command documentation
• Verify command syntax
• Build instrument command sequences
• Execute instrument command sequences
• Integrate sequences in MATLAB, Visual Studio, Excel, LabVIEW, Agilent VEE or Agilent SystemVue PC application
environment
• Generate code for command sequences in MATLAB, Visual C#, Visual Basic.NET and Visual C/C++
• Profile command execution time
• Debug command sequences using breakpoints and single stepping
Step 3. Add X-Series Measurement Applications for Modular Instruments 4 (optional)
Provides essential RF conformance measurements and tasks for specific communications standards.
Transportable, perpetual licenses support up to 4 modular VSAs in one chassis.
M9080A/B
LTE FDD, LTE-Advanced FDD
M9082A/B
LTE TDD, LTE-Advanced TDD
M9073A
W-CDMA/HSPA+
M9071A
GSM/EDGE/EVO
M9079A
TD-SCDMA/HSPA
M9076A
1xEV-D0
M9072A
cdma2000®/cdmaOne
M9077A
WLAN 802.11a/b/g/n/ac
M9063A
Analog modulation
M9064A
VXA vector signal analysis
M9081A
Bluetooth®
1. Both IO library (version 16.3 or newer) and Connection Expert software need to be installed on the PC controlling the equipment. To
download, visit www.agilent.com/find/iosuite
2. Find latest versions of this software at www.agilent.com/find/m9393a
3. To download or get more information on Command Expert, visit www.agilent.com/find/commandexpert
4. For more information, see "Accelerate PXI VSA Measurements with X-Series Measurement Applications", literature number 5991-2604EN.
8
E. Select sofware for M9393A PXIe performance VSA (cont'd)
Step 4. Add 89600 VSA Software 1 (optional)
Provides time, spectrum and stepped spectrum mesaurements, powerful displays, data recording and playback, links to Matlab and more
89601B-200
Basic 89600 VSA software
89601B-300
Hardware connectivity to over 40 Agilent instruments, including the M9393A PXIe VSA
Measurement options
89601B-SSA
Spectrum analysis 2
89601B-AYA
General purpose vector modulation analysis of over 30 types of presets
89601B-BHF
Custom OFDM modulation analysis of prprietary and pre-standard OFDM formats
89601B-B7R
WLAN 802.11a/b/g/j/p
89601B-B7Z
WLAN 802.11n MIMO
89601B-BHJ
WLAN 802.11ac MIMO (requires 89601B-B7Z)
89601B-BHD
LTE FDD
89601B-BHG
LTE-Advanced FDD
89601B-BHE
LTE TDD
89601B-BHH
LTE-Advanced TDD
89601B-B7T
cdma2000®/cdmaOne
89601B-B7U
W-CDMA/HSPA+
89601B-B7W
1xEV-DO
89601B-B7X
TD-SCDMA
89601B-B7R
3G Bundle (includes cdma2000®, W-CDMA/HSPA+, 1xEV-DO & TD-SCDMA options)
89601B-BHC
RFID
89601B-BHK
Custom IQ
1. For more information, see 89600 VSA software configuration guide literature number 5990-6386EN.
2. For best speed, M9393A-UNZ and -B16 are recommended.
9
F. Select services: Warranty, calibration, start-up assistance
One day start-up assistance
Included in base configuration
Return to Agilent warranty - 3 years
Included in base configuration
R-51B-001-5Z
Return to Agilent warranty - 5 years
M9393A-UK6
Commercial calibration certificate with
test data for M9393A (M9308A,
M9365A, M9214A)
M9300A-UK6
Commercial calibration certificate with
test data for M9300A
R-51B-001-3X
Express warranty - 5 day turnaround
For 3 years
R-51B-001-5X
Express warranty - 5 day turnaround
For 5 years
Calibration certificate with measurement results available
only at time of purchase.
Calibration certificate with measurement results available
only at time of purchase.
Available in the US, Japan, China and many EU countries
Available in the US, Japan, China and many EU countries
N7800A Calibration and adjustment software
Global warranty
One day start-up assistance
Agilent Technologies provides the peace of mind that today’s
high tech industry requires. Your investment is protected
by Agilent’s global reach in more than 100 countries (either
directly or through distributors). The warranty gives you
convenient standard coverage for the country in which the
product is used, eliminating the need to ship equipment
back to the country of purchase. Agilent’s warranty service
provides:
An Agilent Technologies applications engineer will get you
started quickly by helping you install the modules in a chassis, configure the controller, load software and start making
measurements.
Calibration services
• Return shipment
The modular products are factory calibrated and shipped
with an ISO-9002, NIST-traceable calibration certificate. A
one year calibration cycle is recommended. The M9393A
PXIe performance VSA is supported by the Agilent N7800A
calibration software to perform calibrations that test all
product specifications and is compliant with ISO 17025:2005,
ANSI/NCSL Z540.3-2006 and measurement uncertainty per
ISO Guide to Expression of Measurement Uncertainty 1995.
Express warranty
N7800A calibration & adjustment software
Reduce downtime with the fastest repair service in the
industry. The express warranty upgrades the global warranty
to provide:
The M9393A PXIe performance VSA is supported by Agilent's
calibration and adjustment software. This is the same software used at Agilent's service centers to automate calibration. The software offers compliance tests for ISO 17025:2005,
ANSI/NCSL Z540.3-2006, and measurement uncertainty per
ISO Guide to Expression of Measurement Uncertainty.
• All parts and labor necessary to return your investment to full specified performance
• Recalibration for products supplied originally with a calibration certificate
• 5 day typical turnaround repair service in the US, Japan,
China and many EU countries or up to a 10 day improvement in turnaround time in the rest of the world
• Priority return shipment
Product Information: www.agilent.com/find/contactus
Or call: 1 800 829-4444 US
Repair and Calibration: www.agilent.com/find/infoline
Parts and Accessories: www.parts.agilent.com
For all modular products: www.agilent.com/find/modular
10
CONFIGU R A T ION
In the base configuration shown below, the M9300A PXIe frequency reference is ordered as an option to the M9393A PXIe
performance VSA.
Cables for module to module connections are shipped with the product. Additional cables for external connections shipped with
the product are listed below.
Please see the M9393A startup guide for detailed cabling diagram and parts list.
Single M9393A PXIe performance VSA
Additional cables shipped:
• One 8121-2063 (BNC Male-SMB Female 1200mm) for external reference connection
• One 8120-5091 (SMB Female-SMB Female 120mm) for longer connection from M9300A 100 MHz Out to M9214A 100 MHz In
• One 8121-2636 (SMB Female-SMP Female 240mm) for longer connection from M9300A 100 MHz Out to M9308A 100 MHz In
Single PXIe performance VSA (M9393A) in chassis
11
Upgrading your system
Your product can be easily upgraded after the initial purchase. All PXIe VSA options are controlled by a licensing key and can
be quickly upgraded by the user.
How to upgrade your M9393A PXIe performance VSA:
1. Contact your Agilent representative to place an order for an option upgrade.
2. You will receive your hardware entitlement certificate via email.
3. Redeem the certificate online by following the instructions provided to receive a license key file.
4. Install the license key file using the Agilent License Manager.
5. Begin using the new capability.
Using a non-Agilent chassis
The M9393A (with M9300A frequency reference) can be successfully installed in a non-Agilent PXI chassis. Please use the
following guidelines.
• Ensure that the chassis has 5 consecutive PXIe or PXI-H slots which can be used by the M9393A and M9300A.
• Ensure that the chassis and controller supports peer-to-peer PXI Express I/O switch topology.
• Ensure that controller selected is compatible with chassis.
Please contact your Agilent representative for more detailed information. For technical assistance with non-Agilent equipment,
please refer to the equipment manufacturer’s website.
12
PC requirements for M9393A PXIe performance VSA control 1
Windows 7
Operating system
Windows 7 (32 & 64 bit)
Processor speed
1.5 GHz dual core (x86 or x64) minimum,
2.4 GHz recommended
No support for Itanium64
Available memory 4 GB minimum
8 GB recommended
Available disk
space1
1.5 GB available hard disk space includes:
1 GB for Microsoft.NET framework 3.5 SPI 2
100 MB for Agilent IO libraries suite 1.5 GB available hard disk space includes:
1 GB for Microsoft.NET framework 3.5 SPI 2
100 MB for Agilent IO libraries suite
Video
Support for DirectX 9 graphics with 128 MB graphics recommended (SuperVGA supported)
Browser
Microsoft Internet Explorer 7.0 or greater
Related literature
For more detailed product and specification information refer to the following literature and web pages:
• M9018A PXIe 18 slot Chassis Data Sheet (literature no. 5990-6583EN)
• M9037A PXIe High Performance Embedded Controller Data Sheet (literature no. 5991-3661EN)
• M9036A PXIe Embedded Controller Data Sheet (literature no. 5990-8465EN)
• X-Series Measurement Applications for Modular Instruments Brochure (literature no. 5991-2604EN)
13
The modular tangram
The four-sided geometric symbol that appears in this document is called a tangram. The goal of this seven-piece puzzle
is to create identifiable shapes—from simple to complex.
As with a tangram, the possibilities may seem infinite as
you begin to create a new test system. With a set of clearly
defined elements—hardware, software—Agilent can help
you create the system you need, from simple to complex.
Challenge the Boundaries of Test
Agilent Modular Products
myAgilent
myAgilent
www.agilent.com/find/myagilent
www.pxisa.org
Three-Year Warranty
www.agilent.com/find/ThreeYearWarranty
Agilent Assurance Plans
www.agilent.com/find/AssurancePlans
www.agilent.com/quality
Agilent Solution Partners
www.agilent.com/find/solutionpartners
www.agilent.com
www.agilent.com/find/modular
www.agilent.com/find/m9393a
For more information on Agilent Technologies’ products,
applications or services, please contact your local Agilent office.
The complete list is available at: www.agilent.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
(11) 4197 3600
01800 5064 800
(800) 829 4444
Asia Pacific
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 375 8100
Europe & Middle East
Belgium
Denmark
Finland
France
Germany
Ireland
Israel
Italy
Netherlands
Spain
Sweden
United Kingdom
32 (0) 2 404 93 40
45 45 80 12 15
358 (0) 10 855 2100
0825 010 700*
*0.125 €/minute
49 (0) 7031 464 6333
1890 924 204
972-3-9288-504/544
39 02 92 60 8484
31 (0) 20 547 2111
34 (91) 631 3300
0200-88 22 55
44 (0) 118 927 6201
For other unlisted countries: www.agilent.com/find/contactus
(BP-10-02-13)
PICMG and the PICMG logo, CompactPCI and the CompactPCI logo,
AdvancedTCA and the AdvancedTCA logo are US registered trademarks
of the PCI Industrial Computers Manufacturers Group. “PCIe” and “PCI
EXPRESS” are registered trademarks and/or service marks of PCI-SIG.
cdma2000 is a registered certification mark of the Telecommunications
Industry Association. Bluetooth and the Bluetooth logos are trademarks
owned by Bluetooth SIG, Inc., USA and licensed to Agilent Technologies, Inc.
WiMAX and Mobile WiMAX are US trademarks of the WiMAX Forum.
Product specifications and descriptions in this document subject to change
without notice.
© Agilent Technologies, Inc. 2014
Published in USA, May 8, 2014
5991-4580EN
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement