Agilent M9393A PXIe Performance Vector Signal Analyzer Configuration Guide 9 kHz to 8.4 GHz, 14 GHz, 18 GHz or 27 GHz Challenge the Boundaries of Test Agilent Modular Products O VERV IE W This configuration guide contains information to help you configure your M9393A PXIe performance vector signal analyzer (PXIe performance VSA) and tailor a system to meet your requirements. Ta b le of c o n t e n t s Page number Hardware A: Select options for M9393A PXIe performance VSA...........................................................................................................................3 B: Add M9300A PXIe frequency reference................................................................................................................................................3 C: Select controller .......................................................................................................................................................................................4 D: Select a chassis & accessories..............................................................................................................................................................6 Physical connection diagram for controllers, chassis & accessories..............................................................................................7 Software E: Select software for M9393A PXIe performance VSA.........................................................................................................................8 Services F: Select services: Warranty, calibration, start-up assistance........................................................................................................... 10 Configuration Single M9383A PXIe performance VSA................................................................................................................................................... 11 Other Upgrading your system............................................................................................................................................................................... 12 Using an M9393A in a non-Agilent chassis............................................................................................................................................ 12 PC requirements for M9393A control...................................................................................................................................................... 13 Related literature......................................................................................................................................................................................... 13 2 A. Select options for M9393A PXIe performance VSA Step 1. Start with M9393A PXIe performance VSA base configuration The M9393A PXIe performance VSA base configuration (occupies 4 slots) includes: M9308A M9365A M9214A PXIe synthesizer PXIe downconverter PXIe IF digitizer • • • • • • Frequency range 9 kHz - 8.4 GHz Analysis bandwidth 40 MHz Memory 128 MSa (512 MB) One day start up assistance Modular interconnect cables Software, example programs and product information on CD • Return to Agilent warranty - 3 years Step 2. Choose a frequency range M9391A-F08 9 kHz − 8.4 GHz M9391A-F14 9 kHz − 14 GHz M9391A-F18 9 kHz − 18 GHz M9391A-F27 9 kHz − 27 GHz Included in base configuration Step 3. Choose an analysis bandwidth M9393A-B04 40 MHz M9393A-B10 100 MHz M9393A-B16 160 MHz Included in base configuration Step 4. Choose memory size M9393A-M01 128 MSa M9393A-M05 512 MSa M9393A-M10 1024 MSa Included in base configuration Step 5. Add fast switching speed (optional) Accelerates test throughput and stepped spectrum analysis M9393A-UNZ Fast tuning Step 6. Add pre-amplifier (optional) Enhances sensitivity to detect low-level signals M9393A-P08 100 kHz − 8.4 GHz M9393A-P14 100 kHz − 14 GHz M9393A-P18 100 kHz − 18 GHz M9393A-P27 100 kHz − 27 GHz B. Add M9300A PXIe frequency reference Step 1. Add an M9300A PXIe frequency reference (occupies 1 slot) One frequency reference required per chassis to meet data sheet specifications. It can support up to four M9393A PXIe VSAs M9393A-300 Adds M9300A PXIe frequency reference Five 100 MHz outputs One 10 MHz output Internal 10 MHz OCXO timebase output 3 C. Select controller (either embedded controller or via PC) 1 Step 1. If selecting an embedded controller, select either M9036A or M9037A 2 M9036A-M04 Mid-performance embedded controller Intel i5-520E dual-core, 2.4 GHz, 4 thread, 4GB RAM Select the M9036A for mid-performance, lower cost or if your application requires XP operating system M9037A-M04 High-performance embedded controller Intel i7-4700EQ quad-core processor, 2.4 GHz, 8 thread, 4GB RAM Select M9037A for the best performance if you have memory intensive applications, multiple applications running in parallel, or if a lot of data is sent to the PC from the PXIe chassis. Features removable SSD drive for security and x8 connector from front for connection to second chassis Step 2. Upgrade from standard memory size (optional) For M9036A M9036A-M08 Memory upgrade from 4 GB to 8 GB RAM M9037A-M08 Memory upgrade from 4 GB to 8 GB RAM M9037A-M16 Memory upgrade from 4 GB to 16 GB RAM For M9037A Step 3. Select an operating system For M9036A M9036A-WE3 Microsoft Windows Embedded Standard 7 (32-bit) M9036A-WE6 Microsoft Windows Embedded Standard 7 (32-bit) M9037A-WE3 Microsoft Windows Embedded Standard 7 (32-bit) M9037A-WE6 Microsoft Windows Embedded Standard 7 (32-bit) For M9037A 1. For list of qualified external controllers, please see Tested Computer List Technical Note literature no. 5990-7632EN. The M9021A is used for both PC controllers and can only be used in the M9018A chassis. 2. The M9018A 18-slot chassis includes empty space to the left of the 1st functional slot. The embedded controller occupies that empty space and the 1st functional slot. 4 C. Select controller (either embedded controller or via PC) 1 (continued) To use your Laptop PC as a controller M9045B PCIe ExpressCard adaptor Y1200B PCIe cable M9021A PCIe cable interface2 : 1 slot To use your Desktop PC as a controller M9048A PCIe desktop adaptor Y1202A PCIe cable M9021A PCIe cable interface2 : 1 slot 1. For list of qualified external controllers, please see Tested Computer List Technical Note literature no. 5990-7632EN. See physical connections diagram on page 8. 2. The M9021A is used for either PC control option and can only be used with the Agilent M9018A 18-slot chassis. 5 D. Select a chassis and accessories Step 1. Select a chassis M9018A 18-slot PXIe chassis Step 2. Choose enough slot blocker kits and EMC filler panels to fill every open slot Recommended to achieve data sheet specifications Y1212A Slot blocker kit: 5 slots Y1213A PXI EMC filler panel kit: 5 slots Step 3. Choose a rack mount kit (optional) Y1215A Rack mount kit for M9018A 18-slot PXIe chassis Step 4 Choose an air inlet kit1 (optional) Recommended for rack mounted systems with less than 1U space below chassis. Y1214A Air inlet kit: M9018A 18-slot chassis1 1. Available in 1-slot, 2-slot or 3-slot options depending on the chassis configuration. For more information, please visit www.agilent.com/find/m9018a 6 P HY SICAL C ONNEC T IONS Physical connection diagram for controllers External laptop PC control ptions Embedded controller M9045B PCIe ExpressCard adaptor M9036A or M9037A embedded controller Y1200B PCIe cable M9021A PXIe cable interface M9393A PXIe performance VSA placed inside the M9018A PXIe chassis Y1202A PCIe cable M9048A PCIe adapter External desktop PC control options 7 E. Select software for M9393A PXIe performance VSA Step 1. Start with M9393A base configuration The M9393A comes standard with the following software: • Agilent IO Libraries Suite including Connection Expert 1 • Instrument software, soft front panel, drivers for use with Matlab, LabVIEW, Visual Studio (including VB Net, C#, C/C++), Agilent VEE 2 • Sample waveforms and programming examples Step 2. Download free Agilent Command Expert software 3 (optional) FREE software that provides fast and easy instrument control for the PC. Command Expert combines instrument command sets, command sequences, documentation, syntax checking and command execution in one simple interface. Command Expert helps you to: • Find instrument commands • Access command documentation • Verify command syntax • Build instrument command sequences • Execute instrument command sequences • Integrate sequences in MATLAB, Visual Studio, Excel, LabVIEW, Agilent VEE or Agilent SystemVue PC application environment • Generate code for command sequences in MATLAB, Visual C#, Visual Basic.NET and Visual C/C++ • Profile command execution time • Debug command sequences using breakpoints and single stepping Step 3. Add X-Series Measurement Applications for Modular Instruments 4 (optional) Provides essential RF conformance measurements and tasks for specific communications standards. Transportable, perpetual licenses support up to 4 modular VSAs in one chassis. M9080A/B LTE FDD, LTE-Advanced FDD M9082A/B LTE TDD, LTE-Advanced TDD M9073A W-CDMA/HSPA+ M9071A GSM/EDGE/EVO M9079A TD-SCDMA/HSPA M9076A 1xEV-D0 M9072A cdma2000®/cdmaOne M9077A WLAN 802.11a/b/g/n/ac M9063A Analog modulation M9064A VXA vector signal analysis M9081A Bluetooth® 1. Both IO library (version 16.3 or newer) and Connection Expert software need to be installed on the PC controlling the equipment. To download, visit www.agilent.com/find/iosuite 2. Find latest versions of this software at www.agilent.com/find/m9393a 3. To download or get more information on Command Expert, visit www.agilent.com/find/commandexpert 4. For more information, see "Accelerate PXI VSA Measurements with X-Series Measurement Applications", literature number 5991-2604EN. 8 E. Select sofware for M9393A PXIe performance VSA (cont'd) Step 4. Add 89600 VSA Software 1 (optional) Provides time, spectrum and stepped spectrum mesaurements, powerful displays, data recording and playback, links to Matlab and more 89601B-200 Basic 89600 VSA software 89601B-300 Hardware connectivity to over 40 Agilent instruments, including the M9393A PXIe VSA Measurement options 89601B-SSA Spectrum analysis 2 89601B-AYA General purpose vector modulation analysis of over 30 types of presets 89601B-BHF Custom OFDM modulation analysis of prprietary and pre-standard OFDM formats 89601B-B7R WLAN 802.11a/b/g/j/p 89601B-B7Z WLAN 802.11n MIMO 89601B-BHJ WLAN 802.11ac MIMO (requires 89601B-B7Z) 89601B-BHD LTE FDD 89601B-BHG LTE-Advanced FDD 89601B-BHE LTE TDD 89601B-BHH LTE-Advanced TDD 89601B-B7T cdma2000®/cdmaOne 89601B-B7U W-CDMA/HSPA+ 89601B-B7W 1xEV-DO 89601B-B7X TD-SCDMA 89601B-B7R 3G Bundle (includes cdma2000®, W-CDMA/HSPA+, 1xEV-DO & TD-SCDMA options) 89601B-BHC RFID 89601B-BHK Custom IQ 1. For more information, see 89600 VSA software configuration guide literature number 5990-6386EN. 2. For best speed, M9393A-UNZ and -B16 are recommended. 9 F. Select services: Warranty, calibration, start-up assistance One day start-up assistance Included in base configuration Return to Agilent warranty - 3 years Included in base configuration R-51B-001-5Z Return to Agilent warranty - 5 years M9393A-UK6 Commercial calibration certificate with test data for M9393A (M9308A, M9365A, M9214A) M9300A-UK6 Commercial calibration certificate with test data for M9300A R-51B-001-3X Express warranty - 5 day turnaround For 3 years R-51B-001-5X Express warranty - 5 day turnaround For 5 years Calibration certificate with measurement results available only at time of purchase. Calibration certificate with measurement results available only at time of purchase. Available in the US, Japan, China and many EU countries Available in the US, Japan, China and many EU countries N7800A Calibration and adjustment software Global warranty One day start-up assistance Agilent Technologies provides the peace of mind that today’s high tech industry requires. Your investment is protected by Agilent’s global reach in more than 100 countries (either directly or through distributors). The warranty gives you convenient standard coverage for the country in which the product is used, eliminating the need to ship equipment back to the country of purchase. Agilent’s warranty service provides: An Agilent Technologies applications engineer will get you started quickly by helping you install the modules in a chassis, configure the controller, load software and start making measurements. Calibration services • Return shipment The modular products are factory calibrated and shipped with an ISO-9002, NIST-traceable calibration certificate. A one year calibration cycle is recommended. The M9393A PXIe performance VSA is supported by the Agilent N7800A calibration software to perform calibrations that test all product specifications and is compliant with ISO 17025:2005, ANSI/NCSL Z540.3-2006 and measurement uncertainty per ISO Guide to Expression of Measurement Uncertainty 1995. Express warranty N7800A calibration & adjustment software Reduce downtime with the fastest repair service in the industry. The express warranty upgrades the global warranty to provide: The M9393A PXIe performance VSA is supported by Agilent's calibration and adjustment software. This is the same software used at Agilent's service centers to automate calibration. The software offers compliance tests for ISO 17025:2005, ANSI/NCSL Z540.3-2006, and measurement uncertainty per ISO Guide to Expression of Measurement Uncertainty. • All parts and labor necessary to return your investment to full specified performance • Recalibration for products supplied originally with a calibration certificate • 5 day typical turnaround repair service in the US, Japan, China and many EU countries or up to a 10 day improvement in turnaround time in the rest of the world • Priority return shipment Product Information: www.agilent.com/find/contactus Or call: 1 800 829-4444 US Repair and Calibration: www.agilent.com/find/infoline Parts and Accessories: www.parts.agilent.com For all modular products: www.agilent.com/find/modular 10 CONFIGU R A T ION In the base configuration shown below, the M9300A PXIe frequency reference is ordered as an option to the M9393A PXIe performance VSA. Cables for module to module connections are shipped with the product. Additional cables for external connections shipped with the product are listed below. Please see the M9393A startup guide for detailed cabling diagram and parts list. Single M9393A PXIe performance VSA Additional cables shipped: • One 8121-2063 (BNC Male-SMB Female 1200mm) for external reference connection • One 8120-5091 (SMB Female-SMB Female 120mm) for longer connection from M9300A 100 MHz Out to M9214A 100 MHz In • One 8121-2636 (SMB Female-SMP Female 240mm) for longer connection from M9300A 100 MHz Out to M9308A 100 MHz In Single PXIe performance VSA (M9393A) in chassis 11 Upgrading your system Your product can be easily upgraded after the initial purchase. All PXIe VSA options are controlled by a licensing key and can be quickly upgraded by the user. How to upgrade your M9393A PXIe performance VSA: 1. Contact your Agilent representative to place an order for an option upgrade. 2. You will receive your hardware entitlement certificate via email. 3. Redeem the certificate online by following the instructions provided to receive a license key file. 4. Install the license key file using the Agilent License Manager. 5. Begin using the new capability. Using a non-Agilent chassis The M9393A (with M9300A frequency reference) can be successfully installed in a non-Agilent PXI chassis. Please use the following guidelines. • Ensure that the chassis has 5 consecutive PXIe or PXI-H slots which can be used by the M9393A and M9300A. • Ensure that the chassis and controller supports peer-to-peer PXI Express I/O switch topology. • Ensure that controller selected is compatible with chassis. Please contact your Agilent representative for more detailed information. For technical assistance with non-Agilent equipment, please refer to the equipment manufacturer’s website. 12 PC requirements for M9393A PXIe performance VSA control 1 Windows 7 Operating system Windows 7 (32 & 64 bit) Processor speed 1.5 GHz dual core (x86 or x64) minimum, 2.4 GHz recommended No support for Itanium64 Available memory 4 GB minimum 8 GB recommended Available disk space1 1.5 GB available hard disk space includes: 1 GB for Microsoft.NET framework 3.5 SPI 2 100 MB for Agilent IO libraries suite 1.5 GB available hard disk space includes: 1 GB for Microsoft.NET framework 3.5 SPI 2 100 MB for Agilent IO libraries suite Video Support for DirectX 9 graphics with 128 MB graphics recommended (SuperVGA supported) Browser Microsoft Internet Explorer 7.0 or greater Related literature For more detailed product and specification information refer to the following literature and web pages: • M9018A PXIe 18 slot Chassis Data Sheet (literature no. 5990-6583EN) • M9037A PXIe High Performance Embedded Controller Data Sheet (literature no. 5991-3661EN) • M9036A PXIe Embedded Controller Data Sheet (literature no. 5990-8465EN) • X-Series Measurement Applications for Modular Instruments Brochure (literature no. 5991-2604EN) 13 The modular tangram The four-sided geometric symbol that appears in this document is called a tangram. The goal of this seven-piece puzzle is to create identifiable shapes—from simple to complex. As with a tangram, the possibilities may seem infinite as you begin to create a new test system. With a set of clearly defined elements—hardware, software—Agilent can help you create the system you need, from simple to complex. Challenge the Boundaries of Test Agilent Modular Products myAgilent myAgilent www.agilent.com/find/myagilent www.pxisa.org Three-Year Warranty www.agilent.com/find/ThreeYearWarranty Agilent Assurance Plans www.agilent.com/find/AssurancePlans www.agilent.com/quality Agilent Solution Partners www.agilent.com/find/solutionpartners www.agilent.com www.agilent.com/find/modular www.agilent.com/find/m9393a For more information on Agilent Technologies’ products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada Brazil Mexico United States (877) 894 4414 (11) 4197 3600 01800 5064 800 (800) 829 4444 Asia Pacific Australia China Hong Kong India Japan Korea Malaysia Singapore Taiwan Other AP Countries 1 800 629 485 800 810 0189 800 938 693 1 800 112 929 0120 (421) 345 080 769 0800 1 800 888 848 1 800 375 8100 0800 047 866 (65) 375 8100 Europe & Middle East Belgium Denmark Finland France Germany Ireland Israel Italy Netherlands Spain Sweden United Kingdom 32 (0) 2 404 93 40 45 45 80 12 15 358 (0) 10 855 2100 0825 010 700* *0.125 €/minute 49 (0) 7031 464 6333 1890 924 204 972-3-9288-504/544 39 02 92 60 8484 31 (0) 20 547 2111 34 (91) 631 3300 0200-88 22 55 44 (0) 118 927 6201 For other unlisted countries: www.agilent.com/find/contactus (BP-10-02-13) PICMG and the PICMG logo, CompactPCI and the CompactPCI logo, AdvancedTCA and the AdvancedTCA logo are US registered trademarks of the PCI Industrial Computers Manufacturers Group. “PCIe” and “PCI EXPRESS” are registered trademarks and/or service marks of PCI-SIG. cdma2000 is a registered certification mark of the Telecommunications Industry Association. Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc., USA and licensed to Agilent Technologies, Inc. WiMAX and Mobile WiMAX are US trademarks of the WiMAX Forum. Product specifications and descriptions in this document subject to change without notice. © Agilent Technologies, Inc. 2014 Published in USA, May 8, 2014 5991-4580EN
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement