Installation/Operation Instructions
and Warranty Information for Models...
VR2100
VR2100-R3
SERIES DESCRIPTION
This operating guide describes a series of International Fiber Systems, Inc. (IFS) fiber optic interfaces.
Not all of the interfaces have all of the features in this guide.
The VR2100 series of fiber optic interfaces are designed to receive optical signals from IFS compatible
transmitters with Closed Circuit Television (CCTV) video inputs, as well as convert the optical signals back to
the original electrical video signals. Automatic gain control circuitry is provided for each video channel to
optimize the video images. This series is composed of stand-alone and rack-mount modules that operate with
62.5/125 µ (or 50/125 µ) multimode fiber optic cable.
PART NUMBER DESCRIPTION
VR1001 SERIES
VR2100
VR2100-R3
DUAL VIDEO RECEIVER: 850 nm, AGC, TWO MULTIMODE FIBERS
DUAL VIDEO RECEIVER: 850 nm, AGC, TWO MULTIMODE FIBERS, RACK
MOUNT
COMPATIBILITY CHART
RECEIVER
VR2100
VR2100-R3
COMPATIBLE TRANSMITTER
VT1001, VT1001-R3, VT1000AC, VT1002AC, VT1101M, VT1102M
VT1001, VT1001-R3, VT1000AC, VT1002AC, VT1101M, VT1102M
POWER CONNECTION
(a) Stand-alone Module:
VR2100
24 VAC (center-tapped)
PIN 1
12 VAC
PIN 2
GROUND
PIN 3
12 VAC
International Fiber Systems, Inc.
16 Commerce Road • Newtown, Connecticut 06470 USA • Tel: 203.426.1180 • Fax: 203.426.3326
VR2100 Rev: 1 07/08/99
(b) –R3 Modules:
All “-R3” models receive power from the back plane of the R3 rack. Insert the “-R3” module into any
available R3 rack slot such that the female 3-pin connector on the back of the module engages the companion
male connector of the back plane. The red power LED will glow when voltage is applied to the module.
CAMERA CONNECTION
Attach two 75-ohm coaxial cables (terminated with BNC connectors) from the VIDEO OUT connectors
on the VR2100 series module to the monitor’s video input connectors.
FIBER OPTIC CONNECTION
Select a quality fiber optic cable containing either 62.5/125 µ (or 50/125 µ) fiber, and attach ST style fiber
optic connectors using the connector manufacturer's recommended procedures. Attach one of the fibers to the
OPTICAL INPUT 1 connector on the VR2100 series module, and attach the second fiber to the OPTICAL
INPUT 2 connector.
MOUNTING STAND-ALONE UNITS
Hold the VR2100 series module against the mounting surface and mark the locations of the keyhole slots
on the rear mounting brackets. Install mounting screws into the keyhole marks, allowing leeway under the
screw heads for the box to be mounted. Mount the brackets over the screws, slide, and tighten.
VIDEO LINK OPERATION
Make sure that power is applied to the VR2100 series module, camera, and video monitor. Ensure that
the camera and monitor are turned on, and that any lens cover on the camera has been removed. Verify that
coaxial cables and fiber optic cable are properly terminated and attached to the appropriate connectors.
Successful link operation should be visible at this point as witnessed by a good quality video picture on the
monitor.
International Fiber Systems, Inc.
16 Commerce Road • Newtown, Connecticut 06470 USA • Tel: 203.426.1180 • Fax: 203.426.3326
VR2100 Rev: 1 07/08/99
Simplex multimode
fiber optic cables
From VT1101M, VT1001AC
and VT1001
series module
}
VR2100
DUAL VIDEO RECEIVER
AGC
OPTICAL INPUT 1
VIDEO OUTPUT 1
AGC 1
AGC 2
ifs
International
Fiber
Systems
OPTICAL INPUT 2
Incorporated
Coax cable
203.426.1180
VIDEO OUTPUT 2
POWER
24 VAC
CENTER
TAPPED
AC - 3
CT - 2
AC - 1
Blue
Green
Brown
Video
Monitor
Video
Monitor
Note: To verify the number of fiber optic cables, and fiber optic cable types
of other models within this series, check the compatibility chart and part
number description sections within this manual.
International Fiber Systems, Inc.
LIFETIME WARRANTY
INTERNATIONAL FIBER SYSTEMS, INC. (IFS) warrants to the
original purchaser that all IFS manufactured products shall be free from
defects in material or workmanship at the time of shipment.
LABOR AND PARTS: From the date of purchase to the original user, if
this product is determined to be defective, IFS will repair or replace the
product at no charge.
Our obligation under this warranty is limited only to the repair or
replacment of any of our products, providing said products are used within
the specified ratings and applications, and said products are applied in
accordance with good engineering practices, and providing said products are
proved by our examination to be defective.
This warranty does not extend to any IFS products which have been subject
to acts of God, accident, misuse, abuse, neglect, improper application or
installation, improper operation or maintenance, connection to an improper
voltage supply or to materials which have been altered or repaired outside of
an authorized IFS factory repair center.
This warranty shall constitute the fulfillment of IFS’ liability. IFS shall not
be liable for any incidental or consequential damages or breach of any
express or implied warranty on this product, except to the extent prohibited
by applicable law. Any implied warranty of merchantability or fitness for a
particular purpose of this product is limited in duration to the duration of
this warranty.
Exclusions:
Power transformers, batteries, or cosmetic damage.
16 COMMERCE RD • NEWTOWN, CT 06470 • TEL: 203.426.1180 • FAX: 203.426.3326