2015 Catalogue UPS for ICT UPS for process and service industry UPS for SOHO and SME Who we are Borri is a company specializing in the custom design, manufacturing and servicing of power supply protection systems in key sectors such as ICT, industrial processes and service, oil & gas and energy, utilities, also of static conversion for renewable energy sources. The Borri research and development department is among the most complete regarding the coverage of the various disciplines involved in power conversion. On the strength of proven expertise in product customization and a continuous quest for excellence, Borri is named in more than 40 vendor lists and enjoys a position of prominence in the oil & gas sector. Similarly, with extensive experience in various branches of power electronics such as UPS systems for data centers, inverters for renewable energy projects and storage systems. Borri is a dependable partner able to offer power supply solutions used in ICT applications, in the process industry and for services, with numerous installations to its credit UPSaver®, the most recent three-phase solution, based on Green Conversion patent technology, is able to guarantee unparalleled energy savings, and the best PUE for data centers with lower environmental impact, proof of the ongoing company commitment to innovation. Under the Astrid brand, Borri offers a wide range of renewable energy solutions, reflecting its commitment to our pursuit of sustainable development. Headquartered in Italy, with 15,000 m² of production area and a fully equipped inspection and testing area, the company is able to count on more than 80 years of experience, multidisciplinary R&D and a highly application specialized custom engineering capability. Borri has a presence on all 5 continents with thousands of installations worldwide, professional staff and a network of partners able to provide you value added technical support and services. For more information, visit our website: www.borri.it 4 For PCs, and peripherals. Ideal for home and small office UPS 450-2000 VA Line-interactive 1-phase GIOTTO UPS 1000-3000 VA On-line 1-phase GALILEO 6 For networking, emergency and safety systems. Ideal for small and medium enterprises 8 For server rooms, TLC equipment, emergency and safety systems UPS 6-10 kVA On-line 1-phase LEONARDO 10 Single phase UPS software UPS 10-20 kVA 3/1 and 3/3 phase B8031/B8033 FXS 11 For servers, TLC equipment, emergency, safety systems and industrial automation UPS 30-50 kVA 3/3 phase INGENIO 15 For server rooms, TLC equipment, emergency, safety systems and industrial automation 19 For small-medium data centers, process automation and service industry UPS 60-160 kVA 3/3 phase INGENIO PLUS UPS 60-300 kVA 3/3 phase B9000FXS 23 For data centers, medical equipment, process automation, infrastructure and service industry UPS 400-800 kVA 3/3 phase B9600FXS 27 For data centers, infrastructure, process and service industry 31 4.0 UPS dedicated to ICT for unmatched energy savings UPSAVER 100 kW-12.8 MW STS 25-3000 A STS100/STS300 35 Static Transfer Switches 36 Three phase UPS teleservice GIOTTO 450-2000 VA Line-interactive 2 Single phase UPS for personal computers servers TLC equipment Ideal for SOHO and SME LEONARDO 6 -10 kVA On-line Tower and Rack/Tower GALILEO 1000-3000 VA On-line Tower and Rack/Tower 3 GIOTTO 450-2000 VA Line-interactive 1-phase For PCs and peripherals Ideal for home and small office Features and benefits ● User-friendly UPS ensuring compact protection for a wide range of needs: • Best power protection for PC from 450 to 850 VA with one output receptacle (IEC 320-C13) and one Schuko • Advanced power protection from 1000 to 2000 VA with four output receptacles (IEC 320-C13) and one Schuko for high performance PC and peripherals ● Instantaneous battery back-up power and electrical interference protection ● Plug and Play installation easy to set up also for first user ● Compact and noise-free running to be placed anywhere at home or office ● Energy efficient ensuring lowest impact on energy costs. ● Intuitive LCD display provides easy-to-read UPS status and power information ● Audible alarm alerts upon utility power and UPS status change ● Easy User-replaceable battery ● AVR technology stabilizing output voltage to protect your electronics over a wide range of mains quality issues ● Advanced battery management extending battery life ● Internet Modem / LAN protection via RJ-11/45 plug ● USB communication port providing UPS managements ● Borri Power Guardian user-friendly UPS management software free downloadable at www.borri.it/support (for more info see p.10). Autonomy time in minutes with internal battery 0 2 4 2000 VA 1500 VA 1000 VA 850 VA 650 VA 450 VA Internal battery 50% load 4 6 8 10 12 14 GIOTTO technical data Rating (VA) 450 650 850 1000 1500 2000 Nominal power (W) 270 380 500 600 900 1200 5.5 9 UPS dimensions WxDxH (mm) 100x292x140 5 148x315x198 UPS weight (kg) 4 Input Connection type 1 IEC 320-C14 Nominal voltage 230 Vac Voltage range 10.5 11.8 160÷290 Vac Frequency and range Output 50/60 Hz, 45÷65 Hz 1 IEC 320-C13 and 1 Schuko Connection type Nominal voltage 4 IEC 320-C13 and 1 Schuko 230 Vac single phase Frequency 50/60 Hz Waveform Simulated sine wave Battery 50% load 81011138 9 Autonomy time (min) ◆ 100% load 333333 Connectivity and function extensions Front panel Communication Environmental LCD, ON/OFF button Included: USB. Compatible platforms: Microsoft Windows, Linux, Mac Operating temperature range Altitude (AMSL) 0°C ÷ +40°C < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m Audible noise at 1m (dBA) <40 Relative humidity Standards and certifications 0-95% MarkingCE Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Quality assurance, Environment, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 Health and Safety ◆ Measurement conditions: optimised parameters, battery full charged, Power Factor (PF) 0.6 5 GALILEO 1000-3000 VA On-line 1-phase For networking equipment Ideal for small and medium enterprises Features and benefits ● On-line double conversion UPS from 1000 to 3000 VA, Tower and 2U Rack/Tower from three to six output receptacles (IEC 320-C13) and one or two Schuko ● Rack/Tower convertible design to protect your investment when migrating from tower to rack-mount environment. Both UPS and display panel can be rotated ● Easy installation and set up, user-replaceable and upgradable battery ● Intuitive LCD display providing easy-to-read UPS status and power information ● Audible alarm alerts upon utility power and UPS status change ● Smart cooling system ensuring further energy savings ● Programmable switched outlet group for setting load priorities ● Active harmonic power quality control ensuring 0.99 input PF and THDi<3% for maximum compatibility with sources ● Automatic self test and advanced battery management maximizing battery performance and extending battery life ● Battery extension box allowing additional autonomy time to be quickly added ● Remote power off for immediate UPS shutdown in case of emergency ● USB communication port providing UPS management ● One slot auto-sensing communication cards ● Borri Power Guardian user-friendly UPS management software with alerts upon main power failures and system shutdown notification via sms and email (for more info see p.10), free downloadable at www.borri.it/support Main options ● SNMP Autonomy time in minutes for Rack/Tower UPS 0 10 20 30 40 50 60 70 80 ● Contact relay card to send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts 3 kVA ● Additional battery charger for external battery box (for more info visit www.borri.it) 2 kVA 1 kVA Internal battery N° 1 Battery box N° 2 Battery boxes Autonomy time in minutes for Tower UPS 0 10 20 30 40 50 3 kVA 2 kVA 1 kVA Internal battery 6 card to send UPS status to BMS’s by Ethernet connection and SNMP or ModBus over IP protocol to monitor UPS status by any internet browser from workstations and to receive SMS or e-mail alerts from the UPS on any portable device N° 1 Battery box N° 2 Battery boxes 60 70 80 GALILEO technical data UPS Type T* T* T* RT (2U)** RT (2U)** Rating (VA) 1000 2000 3000 1000 2000 3000 Nominal power (W) 900 1800 2700 900 1800 2700 144x367x236 151x444x322 189x444x322 440x390x88 440x475x88 440x600x88 11.2 18.8 24.9 12.0 17.0 26.5 UPS dimensions WxDxH (mm) UPS weight (kg) Input Connection type 1 IEC 320-C14 Nominal voltage 230 Vac single phase Voltage range 195÷260 Vac Frequency and range 50/60 Hz, 45÷65 Hz Power factor 0.98 Current distortion (THDi) Output Connection type RT (2U)** 0.99 <3% Nominal voltage Frequency Power factor Overload capability Mode of operation Battery 3 IEC 320-C13 1 Schuko 3 IEC 320-C13 2 Schuko 6 IEC 320-C13 3 IEC 320-C13 6 IEC 320-C13 2 Schuko 230 Vac +/-1% single phase 50/60 Hz Any power factor up to 0.9 lagging or leading without power derating 105% continuous, 106-120% for 30 seconds, 121-150% for 10 seconds, >150% immediately transfer to bypass On-line, Eco mode 50% load 121315121315 Autonomy time internal battery (min)◆ 100% load 666666 Connectivity and function extensions Front panel Communication Environmental Operating temperature range Altitude (AMSL) Audible noise at 1m (dBA) Relative humidity Standards and certifications Marking Display LCD, LED signaling, function keys Included: USB, EPO Optional: RS485 card, dry contact card, SNMP card, RS232 card. Compatible platforms: Microsoft Windows, Linux, Mac 0°C ÷ +40°C < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m <50 0-90% CE Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Quality assurance, ISO 14001:2004, BS OHSAS 18001:2007 Environment, Health and Safety *Tower **Rack/Tower ◆ Measurement conditions: optimised parameters, battery full charged, Power Factor (PF) 0.7 7 LEONARDO 6-10 kVA On-line 1-phase For server rooms TLC equipment Emergency and safety systems Features and benefits ● Automatic ● On-line double conversion UPS from 6 to 10 kVA, Tower and 2U or 3U Rack/Tower ● Parallel redundant configuration maxi mizing the availability ● Rack/Tower convertible design to protect your investment when migrating from tower to rack-mount environment. Both UPS and display panel can be rotated ● Easy installation and set up, user-repla- ceable and upgradable battery ● Intuitive LCD display providing easy-to- read UPS status and power information ● Audible alarm alerts upon utility power and UPS status change ● Smart cooling system ensuring further energy savings ● Active harmonic power quality control ensuring 0.99 input PF and THDi<3% for maximum upstream sources self test and advanced battery management maximizing battery performance and extending battery life ● Battery extension box allowing additional autonomy time to be quickly added ● Remote emergency power off to guarantee your piece of mind in critical applications ● Internal manual bypass for safe and easy maintenance ● RS232 communication port providing UPS management ● Two slots auto-sensing communication cards ● Borri Power Guardian user-friendly UPS management software with alerts upon main power failures and system shutdown notification via sms and email (for more info see p.10), free downloadable at www.borri.it/support Main options ● SNMP Autonomy time in minutes for Rack/Tower UPS 10 20 30 40 50 60 70 80 10 kVA 0 ● Contact relay card to send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts 6 kVA compact model 6 kVA ● Additional battery charger for external battery box (for more info visit www.borri.it) Internal battery N° 1 Battery box N° 2 Battery boxes Autonomy time in minutes for Tower UPS 0 10 20 30 10 kVA 6 kVA Internal battery 8 card to send UPS status to BMS’s by Ethernet connection and SNMP or ModBus over IP protocol to monitor UPS status by any internet browser from workstations and to receive SMS or e-mail alerts from the UPS on any portable device N° 1 Battery box 40 50 60 70 80 LEONARDO technical data UPS Type T* T* RT (2U)*** RT (4U)** RT (3U)*** Rating (kVA) 6 10 6 6 10 5.4 9 5.4 5.4 290x645x748 290x645x748 440x680x88 440x680x176 440x680x132 86 96 24 52 26 Nominal power (kW) UPS dimensions WxDxH (mm) UPS weight (kg) Input Connection type Hardwired 2w (input), 2w (bypass) Nominal voltage Hardwired 2w (input) 230 Vac single phase Voltage range 195÷260 Vac Frequency and range 50/60 Hz, 45÷65 Hz Power factor 0.99 Current distortion (THDi) Output <6% Connection type Hardwired 2w Nominal voltage 230 Vac +/- 1% single phase Frequency 50/60 Hz Any power factor up to 0.9 lagging or leading without power derating Power factor Overload capability 104% continuous, 105-150% for 160 seconds, >150% immediately transfer to bypass On-line, Eco mode Mode of operation Battery 50% load Autonomy with internal battery (min)◆ 100% load Connectivity and function extensions Front panel Communication Environmental Operating temperature range Altitude (AMSL) 9 25 17 external battery 15 external battery 9 6 external battery 6 external battery Display LCD, LED signaling, function keys Included: RS232 card, USB, EPO Optional: RS485 card, dry contact card, SNMP card, second RS232 card Compatible platforms: Microsoft Windows, Linux, Mac 0°C ÷ +40°C < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m Audible noise at 1m (dBA)<50 Relative humidity Standards and certifications 0-90% MarkingCE Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Quality assurance, Environment, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 Health and Safety *Tower with internal battery **Rack/Tower with internal battery ***Rack/Tower without internal battery ◆ Measurement conditions: optimised parameters, battery full charged, cos Ø 0.7 9 Single phase UPS software Borri Power Guardian is free user-friendly UPS monitoring software, which provides also in your absence safe system shutdown in the event of blackout or other computer power problems and reveals the status of UPS. Features and benefits ● Fast, easy installation and configuration via USB or RS232 even for first-time users ● Automatic orderly system shutdown: it closed all applications and safely shutdowns ● Computer preventing potential data corruption and hardware damage ● Alerts of main power failures and system shutdowns notification via sms and email ● Automatic self-test of UPS and battery status ensuring early detection of a battery that needs to be replaced ● Real time UPS parameters and power status at glance. It summarizes graphically and numerically power problems such as blackouts or electrical noise over time and UPS information such as input and output voltage, frequency voltage, temperature, loads and battery capacity. ● It allows tailoring settings such as UPS commands to be performed ● Available for MAC and Microsoft operating systems: see complete list at www.borri.it/support ● Download Borri Power Guardian free software at: www.borri.it/support. 10 B8031/B8033FXS 10-20 kVA For servers TLC equipment Emergency and safety systems Industrial automation B8031/B8033FXS 10 to 20 kVA On-line double conversion Transformer free Full IGBT technology Paralleling up to 120 kVA 11 B8031/B8033FXS 10-20 kVA for servers TLC equipment Emergency and safety systems Industrial automation Features and benefits Main options ● High double conversion efficiency and ECO mode for low running costs and environmental impact. ● Transformer free design for light small size layout. ● Removable power modules architecture and built-in diagnostics for easy maintenance and very low MTTR. ● Hot connection/disconnection of parallel units for easy system resizing. ● Full IGBT technology and electronic PFC, ensuring 0.99 input PF and THDi<3% for maximum upstream sources compatibility. ● Wide range of configurations with internal batteries for low TCO compact solutions. ● High power battery charger, suiting long autonomy applications. ● Dual DSP plus microcontroller logics for top performance and reliability. ● CAN-bus based distributed parallel control ensuring high load sharing accuracy and no single point of failure. ● Comprehensive set of communication options for total remote monitoring of equipment operation. ● Included bypass contactor for complete backfeed protection and operators’ safety without additional installation costs. ● Fully compliance with all international product standards for maximum quality guarantee. ● Isolation transformer. ● Transformers/autotransformers for voltage adjustment. ● Battery voltage temperature compensation. ● External maintenance bypass wall-mounted box. ● Battery fuse switch wall-mounted box. ● Associated battery cabinets for long autonomy times. ● Parallel kit for load sharing. ● Load-sync for single UPS units. ● Input terminals for remote EPO, external manual bypass auxiliary contact, diesel mode. ● Separate bypass input for B8033FXS. Autonomy time in minutes with different types of internal batteries 0 5 101520 2530 3540 4550 20 kVA 15 kVA 10 kVA 12 B8031FXS - B8033FXS technical data Rating (kVA)10 Nominal power (kW)9 UPS dimensions WxDxH (mm) 15 450x670x1200 UPS weight (kg) UPS weight with internal battery (kg) External battery module dimensions WxDxH (mm) 100 110 Max.275 Max.275 500x670x1200 Battery configuration Internal or external, 360÷372 cells, VRLA (other options) Max autonomy with int. battery 70% load (min) 49 Input Connection type Nominal voltage 18 110 Max.285 20 13.5 24 12 B8031FXS (10-15-20 kVA) B8033FXS (10-15-20 kVA) Hardwired 4w (rectifier), 2w (bypass) Hardwired 4w (separate bypass input available on request) 400 Vac 3-phase with neutral (rectifier) 220/230/240 Vac 1-phase (bypass) 400 Vac 3-phase with neutral (rectifier) 380/400/415 Vac 3-phase with neutral (bypass) Voltage tolerance -20%, +15% Frequency and range 50/60 Hz (45÷65 Hz) Power factor 0.99 Current distortion (THDi) <3% Output Connection type Nominal voltage Frequency Voltage regulation Power factor Overload capacity B8031FXS (10-15-20 kVA) B8033FXS (10-15-20 kVA) Hardwired 2w Hardwired 4w 220/230/240 Vac 1-phase 380/400/415 Vac 3-phase with neutral 50/60 Hz ±1% static; dynamic: IEC/EN 62040-3 Class 1 up to 0.9, lagging or leading without power derating Inverter: 101÷125% for 10 min, 126÷150% for 30 s, >150% for 10 s; bypass: 150% continuous, 1000% for 1 cycle Efficiency (AC/AC)* Classification as per VFI-SS-111 IEC/EN 62040-3 up to 98% Connectivity and function extensions Front panel Graphic display, mimic LED panel and keyboard, local EPO Remote communicationIncluded: remote communication terminal block for battery breaker auxiliary contact. Optional: input terminal block (remote emergency power off, battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet), Web interface (Ethernet), from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software Optional function extensions Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit, load-sync for single UPS System Protection degree IP 20 Colour RAL 7016 Installation layout 10 cm wall-gap, side by side installation allowed Accessibility Front and top access, bottom cable entry *according to IEC/EN 62040-3 Other features Environmental Operating temperature range 0°C ÷ +40°C Storage temperature range -10°C ÷ +70°C Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m Audible noise at 1 m (dBA) <52 Standards and certifications Quality assurance, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 environment, health and safety Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Environmental aspects IEC/EN 62040-4 Test and performance IEC/EN 62040-3 Protection degree IEC 60529 MarkingCE 13 B8031/8033FXS series options Description When do I use it Parallel kit When the unit is to be paralleled for load sharing Load-sync for single units To synchronize single units’ output for no-break load transfers by downstream static transfer switches Backfeed protection bypass contactor To be fully protected against backfeed energy upon static bypass failure 1-phase output isolation transformer for B8031FXS To galvanically isolate UPS from load or to change system’s earth arrangement 3-phase input isolation transformer for B8033FXS To galvanically isolate UPS from load or to change system’s earth arrangement Battery fused switch box To disconnect and protect an external battery pack (wall mounted box) Internal battery temperature probe When the unit has internal batteries, for charging voltage compensation with temperature Internal battery + UPS temperature probe When the unit has internal batteries, for charging voltage compensation with temperature and UPS temperature monitoring External battery temperature probe When the unit has external batteries, for charging voltage compensation with temperature (10 m cable length) Dry contact relay card To monitor UPS status by a LED panel from a remote control room Remote monitoring panel To monitor UPS status by a LED panel from a remote control room RS485 ModBus-RTU port To send UPS status to BMS’s by RS485 connection and ModBus-RTU protocol. For telemonitoring and teleservice Web/SNMP Adapter To send UPS status to BMS’s by Ethernet connection and SNMP or ModBus over IP protocol. To monitor UPS status by any internet browser from workstations. To receive SMS or e-mail alerts from the UPS on any portable device Input terminal block for remote EPO When the Emergency Power Off (EPO) has to be commanded by a remote control button Input terminal block for external manual bypass switch auxiliary contact When there is an external maintenance bypass switch, for state monitoring Input terminal block for external battery switch auxiliary contact When there is an external battery switch, for state monitoring Input terminal block for diesel mode contact When battery recharge has to be inhibited over genset operation LOAD LOAD A LOAD B INCLUDED QRA TRANSFORMER OUTPUT TRANSFORMER CABINET INCLUDED 14 INGENIO 30-50 kVA For server rooms TLC equipment Emergency and safety systems Industrial automation INGENIO 30 to 50 kVA Three phase On-line double conversion Transformer free Full IGBT technology Paralleling up to 300 kVA 15 INGENIO 30-50 kVA For server rooms TLC equipment Emergency and safety systems Industrial automation Features and benefits Main options ● High double conversion efficiency and ECO mode for low running costs and environmental impact. ● Transformer free design for light small size layout. ● Removable power modules architecture and built-in diagnostics for easy maintenance and very low MTTR. ● Hot connection/disconnection of parallel units for easy system resizing. ● Full IGBT technology and electronic PFC, ensuring 0.99 input PF and THDi<3% for maximum upstream sources compatibility. ● Wide range of configurations with internal batteries for low TCO compact solutions. ● High power battery charger, suiting long autonomy applications. ● Dual DSP plus microcontroller logics for top performance and reliability. ● CAN-bus based distributed parallel control ensuring high load sharing accuracy and no single point of failure. ● Comprehensive set of communication options for total remote monitoring of equipment operation. ● Fully compliance with all international product standards for maximum quality guarantee. ● Isolation transformer. ● Transformers/autotransformers for voltage adjustment. ● Battery voltage temperature compensation. ● External maintenance bypass wall-mounted box. ● Battery fuse switch wall-mounted box. ● Associated battery cabinets for long autonomy times. ● Parallel kit. ● Load-sync for single UPS units. ● Input terminals for remote EPO, external manual bypass auxiliary contact, diesel mode. ● Separate bypass input. ● Backfeed protection bypass contactor. Autonomy time in minutes with different types of internal batteries 0 510152025 50 kVA 40 kVA 30 kVA 16 INGENIO technical data Rating (kVA) 30 Nominal power (kW) 27 UPS dimensions WxDxH (mm) UPS weight (kg) 40 50 36 45 500x940x1500 140150 190 UPS weight 500 510 550 with int. battery (kg) Battery configuration Internal or external, 360÷372 cells, VRLA (other options) Max autonomy with int. battery 24 16 12 70% load (min) Input Connection type Nominal voltage Hardwired 4w (separate bypass input available on request) 400 Vac 3-phase with neutral (rectifier) 380/400/415 Vac 3-phase with neutral (bypass) Voltage tolerance -20%, +15% (rectifier) ±10% (bypass) Frequency and range 50/60 Hz, 45÷65 Hz Power factor 0.99 Current distortion (THDi) Output <3% Connection type Hardwired 4w 380/400/415 3-phase with neutral Nominal voltage Frequency 50/60 Hz Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1 Power factor up to 0.9, lagging or leading without power derating Overload capacity Inverter: 101÷125% for 10 min, 126÷150% for 30 s, >150% for 100 ms, bypass: 150% continuous, 1000% for 1 cycle Efficiency (AC/AC)* up to 98% Classification as per VFI-SS-111 IEC/EN 62040-3 Connectivity and function extensions Front panel Remote communication Optional function extension Graphic display, mimic LED panel and keyboard, local EPO Included: RS232 card, USB; terminal block for battery breaker auxiliary contact Optional: input terminal block (remote emergency power off, external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.); SNMP adapter (Ethernet), Web interface (Ethernet), from ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit and load-sync for single UPS System Protection degree IP 20 Colour RAL 9005 Installation layout Wall and side by side installation allowed; 50 cm clearance on one side with internal battery *according to IEC/EN 62040-3 Other features Environmental Operating temperature range 0°C ÷ +40°C Storage temperature range -10°C ÷ +70°C Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m Audible noise at 1 m (dBA) <52 Standards and certifications Quality assurance, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 environment, health and safety Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Environmental aspects IEC/EN 62040-4 Test and performance IEC/EN 62040-3 VFI-SS-111 Protection degree IEC 60529 MarkingCE 17 INGENIO 30-40-50 kVA series options LOAD LOAD A Description When do I use it Parallel kit When the unit is to be paralleled for load sharing Load-sync for single units To synchronize single units’ output for no-break load transfers by downstream static transfer switches Backfeed protection bypass contactor To be fully protected against backfeed energy upon static bypass failure Input isolation transformer To galvanically isolate UPS from load or to change system’s earth arrangement Battery fused switch box To disconnect and protect an external battery pack (wall mounted box) Internal battery temperature probe When the unit has internal batteries, for charging voltage compensation with temperature Internal battery + UPS temperature probe When the unit has internal batteries, for charging voltage compensation with temperature and UPS temperature monitoring External battery temperature probe When the unit has external batteries, for charging voltage compensation with temperature (10 m cable length) Dry contact relay card To send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts Remote monitoring panel To monitor UPS status by a LED panel from a remote control room RS485 ModBus-RTU port To send UPS status to BMS’s by RS485 connection and ModBus-RTU protocol. For telemonitoring and teleservice Web/SNMP Adapter To send UPS status to BMS’s by Ethernet connection and SNMP or ModBus over IP protocol. To monitor UPS status by any internet browser from workstations. To receive SMS or e-mail alerts from the UPS on any portable device Input terminal block for remote EPO When the Emergency Power Off (EPO) has to be commanded by a remote control button When the Emergency Power Off (EPO) has to be commanded by a remote control button When there is an external maintenance bypass switch, for state monitoring Input terminal block for external battery switch auxiliary contact When there is an external battery switch, for state monitoring Input terminal block for diesel mode contact When battery recharge has to be inhibited over genset operation LOAD B INCLUDED 18 INGENIO PLUS 60-160 kVA For small-medium data centers Process automation Service industry INGENIO PLUS 60 to 160 kVA Three phase On-line double conversion Transformer free Full IGBT technology Paralleling up to 960 kVA re hu c o br lable e i t e pl ava m Co 19 INGENIO PLUS 60-160 kVA For small-medium data centers Process automation Service industry Features and benefits Main options ● Green Conversion technology, high efficiency even at light load and the lowest TCO in its category. ● ● Ultra High Efficiency mode, the ultimate innovation protecting high immunity grade applications, providing 99% efficiency and lowest operational expenditure. ● Full rated output power, ensuring optimal UPS sizing and utilization. ● Transformer free design for compact, light and sustainable systems. ● Full IGBT technology and electronic PFC, ensuring 0.99 input PF and THDi<3% for maximum upstream sources compatibility. ● Internal battery configurations up to 80 kVA for less floor space and maximum flexibility Isolation transformer. Transformers/autotransformers for voltage adjustment. ● Battery voltage temperature compensation. ● External maintenance bypass wall-mounted box. ● ● Battery fuse switch wall-mounted box. Associated battery cabinets for long autonomy times. ● ● Parallel kit for load sharing. ● Load-sync for single UPS units. Load-sync box for two set of paralleled UPS. ● Local tripping device for bypass disconnector. ● ● Dynamic Charging Mode (DCM) for maximum versatility in long autonomy and low charging time applications. ● ● Intermittent battery charge, with adjustable cycle (27-3 standard cycle) providing capital expenditure protection and extreme efficiency savings. ● Tripping coil for bypass disconnector for complete upstream protection and operator’s safety without additional installation cost. Touch screen display. ● Common battery management for even more compact and cost saving UPS systems ● Load based unit shutdown for highest efficiency in light loaded parallel systems. ● Comprehensive set of communication options for total remote monitoring of equipment operation. ● Fully compliance with all international product standards for maximum quality guarantee. Autonomy time in minutes with different types of internal batteries 0 80 kVA 60 kVA 20 5 10 15 20 INGENIO PLUS technical data Rating (kVA)60 80 100125160 Nominal power (kW) 60 80 100125160 UPS dimensions WxDxH (mm)560x940x1800 UPS weight (kg) 250300320360 380 UPS weight with int. battery (kg)800 Battery configuration Max autonomy with int. battery 70% load (min) 850 - - 16 11 - Input Connection type Nominal voltage Hardwired 4w (rectifier), 4w (bypass) 400 Vac 3-phase with neutral (rectifier) 380/400/415 Vac 3-phase with neutral (bypass) Voltage tolerance -20%, +15% (rectifier) ±10% (bypass) Frequency and range 50/60 Hz, 45÷65 Hz - Internal or external, 360÷372 cells, External 360÷372 cells, VRLA (other options) VRLA (other options) Power factor>0.99 Current distortion (THDi) <3% Output Connection type Nominal voltage Frequency 50/60 Hz Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1 Power factor Overload capacity Hardwired 4w 380/400/415 Vac 3-phase with neutral up to 1, without power derating Inverter: 101÷125% for 10 min, 126÷150% for 30 s, >150% for 0.1 s; bypass: 150% continuous, 1000% for 1 cycle Efficiency (AC/AC)* Classification as per VFI-SS-111 IEC/EN 62040-3 up to 99% Connectivity and function extensions Front panel Graphic display, mimic LED panel and keyboard, local EPO Remote communicationIncluded: serial RS232 and USB, backfeed protection monitoring contact, input terminal block (remote emergency power off, battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont.). Optional: SNMP adapter (Ethernet), Web interface (Ethernet), from ModBus-RTU to PROFIBUS DP adapter. SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software Optional function extension Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets; wall-mounted battery fuse battery thermal probe; parallel kit, load-sync for single UPS and load-sync box (2 UPS systems) System Protection degreeIP20 Colour RAL 9005 Installation layout Wall and side by side installation allowed, 80 cm clearance on one side only with internal battery Accessibility Front access, side access (only with internal battery), bottom cable entry *according to IEC/EN 62040-3 Other features Environmental Operating temperature range 0°C ÷ +40°C Storage temperature range -10°C ÷ +70°C Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m Audible noise at 1 m (dBA) <60 Standards and certifications Quality assurance, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 environment, health and safety Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Environmental aspects IEC/EN 62040-4 Test and performance IEC/EN 62040-3 Protection degree IEC 60529 MarkingCE 21 INGENIO PLUS 60-160 kVA series options Description When do I use it Parallel kit When the unit is to be paralleled for load sharing Load-sync for single units To synchronize single units’ output for no-break load transfers by downstream static transfer switches Load-sync box for two sets of paralleled UPS To synchronize the output of two paralleled UPS systems for no-break load transfers by downstream static transfer switches Tripping coil for bypass disconnector To be fully protected against backfeed energy upon static bypass failure. Detection circuit is included Input transformer (to be installed internally or in extended cabinet) To galvanically isolate UPS from load or to change system’s earth arrangement Battery fused switch box To disconnect and protect an external battery pack (wall mounted box) Internal battery temperature probe When the unit has internal batteries, for charging voltage compensation with temperature Internal battery + UPS temperature probe When the unit has internal batteries, for charging voltage compensation with temperature and UPS temperature monitoring External battery temperature probe When the unit has external batteries, for charging voltage compensation with temperature (10 m cable length) Dry contact relay card To send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts Remote monitoring panel To monitor UPS status by a LED panel from a remote control room RS485 ModBus-RTU port To send UPS status to BMS’s by RS485 connection and ModBus-RTU protocol. For telemonitoring and teleservice Web/SNMP Adapter To send UPS status to BMS’s by Ethernet connection and SNMP or ModBus over IP protocol. To monitor UPS status by any internet browser from workstations. To receive SMS or e-mail alerts from the UPS on any portable device Input terminal block for remote EPO When the Emergency Power Off (EPO) has to be commanded by a remote control button Input terminal block for external manual bypass switch auxiliary contact When there is an external maintenance bypass switch, for state monitoring Input terminal block for external battery switch auxiliary contact When there is an external battery switch, for state monitoring Input terminal block for diesel mode contact When battery recharge has to be inhibited over genset operation LOAD LOAD A LOAD B LOAD SYNC BOX LOAD A LOAD B INCLUDED 22 B9000FXS 60-300 kVA For medium data centers Process automation Medical equipment Emergency and safety systems B9000FXS Three phase On-line double conversion Full IGBT technology Paralleling up to 1.8 MVA 23 B9000FXS 60-300 kVA For medium data centers Process automation Medical equipment Features and benefits Emergency and ● High double conversion efficiency and ECO mode for low running costs and safety systems environmental impact. ● Front access to all critical components for easy maintenance. ● Built-in inverter transformer for DC/AC galvanic protection of industrial type loads. ● Hot connection/disconnection of parallel units for easy system resizing. ● Full IGBT technology and electronic PFC, ensuring 0.99 input PF and THDi<3% for maximum upstream sources compatibility. ● Accurate battery management providing ripple current minimization charge current/voltage control as per batteries manufacturers’ specifications and automatic/manual battery test for maximum battery expected life preservation. ● Dynamic Charging Mode (DCM) for maximum versatility in long autonomy and low charging time applications. ● Smart parallel management in load sharing, load synchronization of single UPS systems and load synchronization of two paralleled systems for optimum protection. ● Dual DSP plus microcontroller logics for top performance and reliability. ● CAN-bus based distributed parallel control ensuring high load sharing accuracy and no single point of failure in parallel systems. ● Comprehensive set of communication options for total remote monitoring of equipment operation. ● Fully compliance with all international product standards for maximum quality guarantee. Main options ● Backfeed ● Bypass protection bypass contactor. isolation transformer. ● Transformers/autotransformers for voltage adjustment. ● Battery voltage temperature compensation. ● External maintenance bypass wall-mounted box. ● Battery fuse switch wall-mounted box. ● Associated battery cabinets for long autonomy times. ● Parallel kit for load sharing. ● Load-sync for single UPS units. ● Load-sync box for two set of paralleled UPS. ● Top cable entry. Dynamic Charging Mode (DCM) The battery charging current can be set above the nominal, up to the DCM limit, in order to manage high capacity battery packs. The extra charging power is fed to the battery, as long as the load does not requires it. This is a firmware enabled feature. Bypass Mains 24 Output B9000FXS technical data Rating (kVA) 60 80 100 125160 200250300 Nominal power (kW)54 72 90 112.5144 180225270 Dimensions WxDxH (mm) 815x825x16701200x860x1900 UPS weight (kg) 570600625 660715 9701090 1170 Battery configuration Input External, 300÷312 cells, VRLA (other options) Connection type Hardwired 3w (rectifier), 4w (bypass) Nominal voltage400 Vac 3-phase (rectifier) 380/400/415 Vac 3-phase with neutral (bypass) Voltage tolerance Frequency and range 50/60 Hz, 45÷65 Hz Power factor 0.99 Current distortion (THDi) <3% -20%, +15% Output Connection type Hardwired 4w Nominal voltage380/400/415 Vac 3-phase with neutral Frequency Voltage regulation Power factor up to 0.9, lagging or leading without power derating Overload capacity Inverter: 101÷125% for 10 min, 126÷150% for 1 min, 151÷199% for 10 s, 200% for 100 ms; bypass: 150% continuous, 1000% for 1 cycle 50/60 Hz ±1% static; dynamic: IEC/EN 62040-3 Class 1 Efficiency (AC/AC)* Classification as per VFI-SS-111 IEC/EN 62040-3 up to 98% Connectivity and function extensions Front panel Graphic display, mimic LED panel and keyboard, local EPO Remote communicationIncluded: serial RS232 and USB; input terminal block for: remote emergency power off (REPO), battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. contact. Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software Optional function extensions Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit, top cable entry; load-sync for single UPS and load-sync box (2 UPS systems); backfeed protection System Protection degree IP 20 (other options) Colour RAL 7016 (other options) Installation layout Wall, back to back and side by side installation allowed Accessibility Front and top access, bottom cable entry *certified by TÜV NORD according to IEC/EN 62040-3 Other features Environmental Operating temperature range Storage temperature range -10°C ÷ +70°C Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m 0°C ÷ +40°C Audible noise at 1m (dBA)<62 Standards and certifications Quality assurance, environment, health and ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 safety Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Environmental aspects IEC/EN 62040-4 Test and performance IEC/EN 62040-3 (VFI-SS-111) Protection degree IEC 60529 MarkingCE 25 B9000FXS series options Description LOAD LOAD A When the unit is to be paralleled for load sharing Load-sync for single units To synchronize single units’ output for no-break load transfers by downstream static transfer switches Load-sync box for two sets of paralleled UPS To synchronize the output of two paralleled UPS systems for no-break load transfers by downstream static transfer switches Backfeed protection bypass contactor To be fully protected against backfeed energy upon static bypass failure Top cable entry (in extended cabinet) To allow input and output cable entry from the top of the unit Bypass isolation transformer (in extended cabinet) To galvanically isolate UPS from load or to change system’s earth arrangement Battery fused switch box To disconnect and protect an external battery pack (wall mounted box) Battery temperature probe For charging voltage compensation with temperature (10 m cable length) Dry contact relay card To send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts Remote monitoring panel To monitor UPS status by a LED panel from a remote control room RS485 ModBus-RTU port To send UPS status to BMS’s by RS485 connection and ModBus-RTU protocol. For telemonitoring and teleservice Web/SNMP Adapter To send UPS status to BMS’s by Ethernet connection and SNMP or ModBus over IP protocol. To monitor UPS status by any internet browser from workstations. To receive SMS or e-mail alerts from the UPS on any portable device Input terminal block for remote EPO When the Emergency Power Off (EPO) has to be commanded by a remote control button Input terminal block for external manual bypass switch auxiliary contact When there is an external maintenance bypass switch, for state monitoring Input terminal block for external battery switch auxiliary contact When there is an external battery switch, for state monitoring Input terminal block for diesel mode contact When battery recharge has to be inhibited over genset operation LOAD B Top cable entry INCLUDED 26 Parallel kit LOAD B LOAD SYNC BOX LOAD A When do I use it B9600FXS 400-800 kVA For data centers Process industry Infrastructure B9600FXS 400 to 800 kVA Three phase On-line double conversion Full IGBT technology Paralleling up to 4.8 MVA 27 B9600FXS 400-800 kVA For data centers Process industry Infrastructure 28 Features and benefits Main options ● High double conversion efficiency and ECO mode for low running costs and environmental impact. ● Front access to all critical components for easy maintenance. ● Built-in inverter transformer for DC/AC galvanic protection of industrial type loads. ● Included backfeed bypass contactor for complete protection and operators’ safety without additional installation costs. ● Hot connection/disconnection of parallel units for easy system resizing. ● Full IGBT technology and electronic PFC, ensuring 0.99 input PF and THDi<3% for maximum upstream sources compatibility. ● Accurate battery management providing ripple current minimization charge current/voltage control as per batteries manufacturers’ specifications and automatic/manual battery test for maximum battery expected life preservation. ● Dynamic Charging Mode (DCM) for maximum versatility in long autonomy and low charging time applications. ● Smart parallel management in load sharing, load synchronization of single UPS systems and load synchronization of two paralleled systems for optimum protection. ● Dual DSP plus microcontroller logics for top performance and reliability. ● CAN-bus based distributed parallel control ensuring high load sharing accuracy and no single point of failure in parallel systems. ● Comprehensive set of communication options for total remote monitoring of equipment operation. ● Fully compliance with all international product standards for maximum quality guarantee. ● Manual bypass in extended cabinet ● Backfeed ● Bypass protection isolation transformer. ● Transformers/autotransformers for voltage adjustment. ● Battery voltage temperature compensation. ● External maintenance bypass wall-mounted box. ● Battery fuse switch wall-mounted box. ● Associated battery cabinets for long autonomy times. ● Parallel kit for load sharing. ● Load-sync for single UPS units. ● Load-sync box for two set of paralleled UPS. ● Top cable entry. Dynamic Charging Mode (DCM) The battery charging current can be set above the nominal, up to the DCM limit, in order to manage high capacity battery packs. The extra charging power is fed to the battery, as long as the load does not requires it. This is a firmware enabled feature. Bypass Mains Output B9600FXS technical data Rating (kVA) 400 500600800 Nominal power (kW) 360 450540720 Dimensions WxHxD (mm) 1990x990x1920 2440x990x20202440x990x20203640x990x1920 UPS weight (kg) 1820 222024003600 Battery configuration Input External, 300÷312 cells, VRLA (other options) Connection type Hardwired 3w (rectifier), 4w (bypass) Nominal voltage400 Vac 3-phase (rectifier) 380/400/415 Vac 3-phase with neutral (bypass) Voltage tolerance Frequency and range 50/60 Hz, 45÷65 Hz Power factor 0.99 Current distortion (THDi) <3% -20%, +15% Output Connection type Hardwired 4w Nominal voltage380/400/415 Vac 3-phase with neutral Frequency 50/60 Hz Voltage regulation ±1% static; dynamic: IEC/EN 62040-3 Class 1 Power factor up to 0.9, lagging or leading without power derating Overload capacity Inverter: 101÷125% for 10 min, 126÷150% for 1 min, 151÷199% for 10 s, 200% for 100 ms; bypass: 150% continuous, 1000% for 1 cycle Efficiency (AC/AC)* Classification as per VFI-SS-111 IEC/EN 62040-3 up to 98% Connectivity and function extensions Front panel Graphic display, mimic LED panel and keyboard, local EPO Remote communicationIncluded: serial RS232 and USB; input terminal block for: remote emergency power off (REPO), battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. contact. Optional: SNMP adapter (Ethernet), Web interface (Ethernet), ModBus-TCP/IP (Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board; remote system monitoring panel; UPS managing and server shutdown software Optional function extensions Isolation transformer; transformers/autotransformers for voltage adjustment; external maintenance bypass; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit; top cable entry; load-sync for single UPS and load-sync box (2 UPS systems) System Protection degree IP 20 (other options) Colour RAL 7016 (other options) Installation layout Wall, back to back and side by side installation allowed Accessibility Front and top access, bottom cable entry *certified by TÜV NORD according to IEC/EN 62040-3 Other features Environmental Operating temperature range Storage temperature range -10°C ÷ +70°C Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m 0°C ÷ +40°C Audible noise at 1m (dBA)<62 Standards and certifications Quality assurance, environment, health and ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 safety Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Environmental aspects IEC/EN 62040-4 Test and performance IEC/EN 62040-3 Protection degree IEC 60529 MarkingCE 29 B9600FXS series options Description LOAD LOAD A Parallel kit When the unit is to be paralleled for load sharing Load-sync for single units To synchronize single units’ output for no-break load transfers by downstream static transfer switches Load-sync box for two sets of paralleled UPS To synchronize the output of two paralleled UPS systems for no-break load transfers by downstream static transfer switches Backfeed protection bypass contactor To be fully protected against backfeed energy upon static bypass failure Top cable entry (in extended cabinet) Maintenance bypass (in extended cabinet) To allow input and output cable entry from the top of the unit. B9600FXS series feature optional maintenance bypass for cost reduction when this is externally provided Bypass isolation transformer (in extended cabinet) To galvanically isolate UPS from load or to change system’s earth arrangement Battery fused switch box To disconnect and protect an external battery pack (wall mounted box) Battery temperature probe For charging voltage compensation with temperature (10 m cable length)) Dry contact relay card To send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts Remote monitoring panel To monitor UPS status by a LED panel from a remote control room RS485 ModBus-RTU port To send UPS status to BMS’s by RS485 connection and ModBus-RTU protocol. For telemonitoring and teleservice Web/SNMP Adapter To send UPS status to BMS’s by Ethernet connection and SNMP or ModBus over IP protocol. To monitor UPS status by any internet browser from workstations. To receive SMS or e-mail alerts from the UPS on any portable device Input terminal block for remote EPO When the Emergency Power Off (EPO) has to be commanded by a remote control button Input terminal block for external manual bypass switch auxiliary contact When there is an external maintenance bypass switch, for state monitoring Input terminal block for external battery switch auxiliary contact When there is an external battery switch, for state monitoring Input terminal block for diesel mode contact When battery recharge has to be inhibited over genset operation LOAD B LOAD SYNC BOX LOAD A When do I use it LOAD B INCLUDED Top cable entry INCLUDED 30 UPSAVER 100 kW-12.8 MW 4.0 UPS dedicated to ICT for unmatched energy savings UPSaver 100 kW to 12.8 MW Modular three phase re hu c o br lable e i t e pl ava m Co 31 UPSAVER 100 kW-12.8 MW 4.0 UPS dedicated to ICT for unmatched energy savings Main options ● Centralized static bypass for UPSaver GPU (Growing Power Unit). ● Modular Features and benefits ● Both modular and stand alone for extreme versatility. ● Patented Green Conversion providing high efficiency and battery care technology for continuous savings on operating and maintenance expenditure. ● Four operating modes providing best efficiency in all conditions: DHE double conversion 96% efficiency, VHE active filtering 97%, ECO mode 98%, UHE highest efficiency 99.5%. ● Four modularity levels for maximum flexibility and quick maintenance. battery for UPSaver GPU. ● Transformers/autotransformers for isolation or voltage adjustment. ● Battery voltage temperature compensation. ● Associated battery cabinets for long autonomy times. ● Parallel kit for load sharing. ● Load-sync for single UPS units. ● Load-sync box for two set of paralleled UPS. ● Tripping coil for bypass disconnector for UPSaver FPU (Fixed Power Unit). ● Touch screen display for UPSaver FPU. ● I/O unit specific design providing real hot expandability and maintenability, with no downtime and no bypass operation. ● Load based module shutdown for highest efficiency at light load. ● Included telemonitoring for total control over system operation. ● Minimum TCO (Total Cost of Ownership) and best PUE (Power Usage Effectiveness) for low environmental footprint data centers. Connectivity and function extensions Front panel Touch screen display for UPSaver GPU, LCD display (optional touch screen display) for UPSaver FPU Remote communication Included: serial RS232 and USB; input terminal block for remote emergency power off (REPO), battery circuit breaker aux. cont., Optional function extensions 32 external maintenance bypass circuit breaker aux. cont. Optional: input terminal block for diesel mode aux. cont., ModBus-TCP/IP (Ethernet); ModBus-RTU (RS485); ModBus-RTU to PROFIBUS DP adapter; SPDT contact relay board Isolation transformer, custom battery cabinets, wall-mounted battery fuse switch box, battery thermal probe parallel kit, load-sync for single UPS and load-sync box (2 UPS systems), tripping coil for bypass disconnector for UPSaver FPU UPSAVER technical data Input Connection type Hardwired 4w (rectifier), 4w (bypass) Nominal voltage 400 Vac 3-phase with neutral (rectifier), 380/400/415 Vac 3-phase with neutral (bypass) Voltage tolerance -20%, +15% (rectifier), ±10% (bypass) Frequency and range 50/60 Hz, 45÷65 Hz Power factor 0.99 Current distortion (THDi) <3% Output Connection type Hardwired 4w Nominal voltage 380/400/415 Vac 3-phase with neutral Frequency 50/60 Hz Voltage regulation (VFI) ±1% static; dynamic: IEC/EN 62040-3 Class 1 Power factor Any power factor (leading or lagging) up to 1, without power derating Overload capability Inverter: 101÷125% for 10 min; 126÷150% for 1 min; bypass: 150% continuous, 1000% for 1 cycle AC/AC efficiency certified by TÜV Up to 99.5% Classification as per IEC/EN 62040-3 VFI-SS-111 Environmental Operating temperature 0°C ÷ +40°C Storage temperature -10°C ÷ +70°C Altitude (AMSL) < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m Audible noise at 1m (dBA) <50 (UHE) System Protection degree IP 20 Colour RAL 9005 Installation layout Wall, back to back and side by side installation allowed Accessibility Front and top access, bottom and top cable entry Parallel configuration Up to 8 UPS, for a total of 12.8 MW Standards and certifications Quality assurance, environment, ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 health and safety Safety IEC/EN 62040-1 EMC IEC/EN 62040-2 Test and performance IEC/EN 62040-3 Protection degree IEC 60529 Marking CE UPSAVER stand alone units FPU (Fixed Power Unit) Rating ✶ 100200 Nominal power (kW) 100 200 UPS dimensions WxDxH (mm) 460x920x1690 800x950x2100 UPS weight (kg) 360 720 * A Fixed Power Unit (FPU) is made of a 100 kW or 200 kW Basic Power Unit (BPU) plus all circuit breakers and control logics for use in stand alone configuration UPSAVER 100 modular units GPU (Growing Power Unit) ◆ Rating 200300400500600 N nominal power (kW) 200 300 400 500 N+1 nominal power (kW) 100 200 300 400 500 UPS dimensions WxDxH (mm) 1420x920x1690 1880x920x1690 2340x920x1690 2800x920x1690 3260x920x1690 UPS weight (kg) 800 1150 1500 1850 2200 600 ◆ A 100 kW Growing Power Unit (GPU) is made of many 100 kW Basic Power Units (BPU) plus an I/0 module including all circuit breakers and control logics required for use in modular configuration UPSAVER 200 modular units GPU (Growing Power Unit) Rating N nominal power (kW) N+1 nominal power (kW) UPS dimensions WxDxH (mm) ✪ 400 600 800 1000 120014001600 400 600 800 1000 1200 1400 1600 200 400 600 800 1000 1200 1400 2350x970x2100 2950x970x21003900x970x2100 4500x970x2100 5100x970x21006800x970x21007400x970x2100 UPS weight (kg) 1660 22602920 3590 419049605560 ✪ A 200 kW Growing Power Unit (GPU) is made of many 200 kW Basic Power Units (BPU) plus a I/0 module including all circuit breakers and control logics required for use in modular configuration 33 UPSAVER series options Description LOAD LOAD A Parallel kit When the unit is to be paralleled for load sharing Load-sync for single units To synchronize single units’ output for no-break load transfers by downstream static transfer switches Load-sync box for two sets of paralleled UPS To synchronize the output of two paralleled UPS systems for no-break load transfers by downstream static transfer switches Backfeed protection bypass contactor for UPSaver GPU To be fully protected against backfeed energy upon static bypass failure Tripping coil for bypass disconnector for UPSaver FPU To be fully protected against backfeed energy upon static bypass failure. Detection circuit is included Isolation transformer To galvanically isolate UPS from load or to change system’s earthing arrangement Battery temperature probe For charging voltage compensation with temperature (10 m cable length) Touch screen display (Included in UPSaver GPU) To access UPS information, measure, alarms and control menu by touch screen advanced graphic user interface. To send UPS status by Ethernet connection and ModBus over IP protocol. To add teleservice and telemonitoring features Dry contact relay card To send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts RS485 ModBus-RTU port To send UPS status to BMS’s by RS485 connection and ModBus-RTU protocol. For telemonitoring and teleservice Input terminal block for remote EPO When the Emergency Power Off (EPO) has to be commanded by a remote control button Input terminal block for external manual bypass switch auxiliary contact When there is an external maintenance bypass switch, for state monitoring Input terminal block for external battery switch auxiliary contact When there is an external battery switch, for state monitoring Input terminal block for diesel mode contact When battery recharge has to be inhibited over genset operation LOAD B LOAD SYNC BOX LOAD A When do I use it LOAD B INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED INCLUDED 34 Three phase UPS TELESERVICE Borri teleservice When total availability is an asset, robust site design must be supported by a comprehensive monitoring system providing continuous UPS data collection, in order to detect any deviation from optimum operation and trigger proper and immediate response, so that anomalies don’t evolve into issues. Downtime is usually the last event of a chain and that’s why early deviation detection and control is the key to perfect operation of critical equipment over time. Borri is fulfilling those needs delivering its UPS telemonitoring and teleservice, 365 days a year. The Headquarter based control room collects real-time UPS information, allowing early corrective action upon anomalies. In case of a critical event, Borri’s remote service engineers get an emergency report for issue severity assessment. They perform a first analysis to determine proper solutions, leading to identification and resolution of all possible operating issues. If needed a local service technician will be dispatched to carry out an on-site visit. Any Borri equipment featuring a network or ModBus card can be remotely monito red. Status and events, are periodically sent to our service engineers providing status reports and data collection for log term analysis. Activation of any critical warnings is immediately sent, as well, allowing early corrective action implementation. The system is fully configurable: IT network integration and data transmission security policy, access levels to information and critical parameters to be monitored can be set according to site peculiarities, so as to always get the best balance between monitoring needs and site safety. Real time alarm notification to appointed emergency staff can be configured, as well, by e-mail, SMS, or other. Features and benefits ● Advanced predictive maintenance, reducing operational expenditure, staffing and on-site spare parts need. ● Early anomaly detection, ensuring 100% availability of critical applications. ● 24/7 monitoring of UPS health status, improving system’s reliability and operating life. ● Time compression between anomaly occurrence and recovery, dramatically reducing MTTR. ● Easy integration with facility IT-networks and total control over configuration, allowing for safe data exchange in high security grade applications. 35 STS100/STS300 25-3000 A Static Transfer Switches Features and benefits Main options ● Continuous monitoring of voltage and frequency and automatic instant (<4ms) transfers for secure power switching without cross connection between sources. ● Short circuit transfer inhibit for robust load protection. ● SCR fault detection and backfeed protection for maximum upstream safety. ● Dual manual bypass for complete source independence during maintenance. ● True oversized neutral (2x In) redundant cooling with monitored fans and redundant (3x3) internal power supply in all system control boards for top product reliability in high availability applications. ● Full front access for easy maintenance. ● Bottom and top cable entry for maximum installation versatility. ● Comprehensive set of communication options for total remote monitoring of equipment operation. ● Fully compliance with all international product standards for maximum quality guarantee. ● Isolation transformer. ● Plug-in breakers. ● Output distribution panels. ● Panel builder version. ● Additional SPDT contact relay board. ● 2-pole configuration (STS 100) or 4 pole configuration (STS 300). ● Operation without neutral (STS300). STS block diagram Bypass 1 Source 1 Input 1 Output Source 2 Loads Input 2 Bypass 2 Description When do I use it Dry contact relay card To send UPS status to PLC’s, SCADA’s or AS400’s by voltage free SPDT contacts RS485 ModBus-RTU port To send UPS status to BMS’s by RS485 connection and ModBus-RTU protocol. For telemonitoring and teleservice INCLUDED 36 STS100 / STS300 technical data Rating (A) 25 50 Dimensions WxHxD (mm) Weight (kg) 80100 100250400 630 STS100 820x835x1475 (custom layout on request) 820x835x1475 Connection type Hardwired 2w Hardwired 4w Nominal voltage110/115/120/220/230/240/277 Vac 1-phase Voltage tolerance±10% (up to ±20% on request) 1220x860x1900 150 190220 265 265290305 615660 Input 800 STS300 Frequency and range 208/380/400/415/440/480 Vac 3-phase with neutral 50/60 Hz, ±2 Hz (up to ±4 Hz on request) Source harmonic voltage unlimited (>20% THD transfer time ≤10ms) content Transfer phase angle 5° ÷ 30° Output Connection type Nominal voltage110/115/120/220/230/240/277 Vac 1-phase Hardwired 2w Hardwired 4w Frequency 208/380/400/415/440/480 Vac 3-phase with neutral 50/60 Hz Transfer time ≤4 ms Transfer mode Break before make, transfer inhibit on fault Load power factor 1 to 0.3 Maximum crest factor 3:1 THD current fedback unlimited from load Overload capacity 125% for 30 min, 150% for 10 min, 200% for 30 s, 2000% for 1 cycle, 4000% for ½ cycle Rendimento (AC/AC) >99% Connectivity and function extensions Front panel Remote communication Optional function extensions Mimic LED panel and keyboard Graphical LCD display, mimic LED panel and keyboard Included: dry contact relay card. Optional: RS232 or RS485 serial port, additional dry contact relay board Included: Dry contact relay card, RS232 and RS485 serial ports, ModBus-RTU protocol. Optional: additional dry contact relay card 2-poles configuration; plug-in circuit breakers, operation without neutral, panel builder execution,output distribution panels, isolation transformer 4-poles configuration, plug-in circuit breakers, operation without neutral, panel builder execution, output distribution panels, isolation transformer System Protection degree IP 20 (other options) Colour Installation layout Wall, back to back and side by side installation allowed Accessibility Front access, bottom and top cable entry RAL 7035 (other options) Other ratings on request Other features Environmental Operating temperature range Storage temperature range Altitude (AMSL) 0°C ÷ +40°C -10°C ÷ +70°C < 1000 m without power reduction, > 1000 with reduction of 0.5% per 100 m Audible noise at 1m (dBA)<62 Standards and certifications Quality assurance, environment, health ISO 9001:2008, ISO 14001:2004, BS OHSAS 18001:2007 and safety Safety IEC/EN 62310-1 EMC IEC/EN 62310-2 Breakers IEC/EN 60947-3 IEEE Standard 446 Transfer voltage limits Protection degree IEC 60529 Performance IEC/EN 62310-3 MarkingCE 37 OMG60002revG - 07-2015 - Due to our policy of continuous development, data in this document is subject to change without notice and becomes contractual only after written confirmation Borri S.p.A. Via 8 Marzo, 2 52011 Bibbiena (AR) Italy Tel. +39 0575 5351 Fax+390575 561811 [email protected] · www.borri.it
* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project
advertisement