300 / 400 / 500 MHZ 2 CHANNEL MSO HMO3002 SERIES
5 4 GSa /s Real Time, Low Noise Flash A /D Converter
oom up to 200,000:1
5 8 MPts Memory,
5 MSO functionality included, HO3508 [HO3516] Logic Probe
with 8 [16] Logic Channels required
5 Serial Bus Trigger and Hardware accelerated Decode including List View.
Options: I2C + SPI + UART/RS-232 (HOO10/HOO11), CAN + LIN (HOO12)
5 Vertical Sensitivity 1mV/div., Offset Control ±0.2…±20V
5 6-Digit Hardware Counter
5 Real-Time FFT (dBm, dBV, Veff), up to 64 kPts
5 Automatic Search for user-defined Events
5 Pass/Fail Test based on Masks
5 Auto-Measurement: max. 6 Parameters incl. Statistic,
Formula Editor, Ratio Cursor
5 Display Range: 12 div. x-Axis, 20 div. y-Axis (VirtualScreen)
5 Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed,
Event, Hold-Off
5 Automatically or manually adjustable Memory Depth
5 3 x USB for Mass Storage and Remote Control
150 MHZ/200 MHZ 2 CHANNEL DSO HMO1522/HMO2022
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
300/400 MHz >>> 500 MHz
Future-proof due to
Bandwidth Upgrade Option
HOO352 / 354 – HOO452 / 454
150 MHZ/200 MHZ 4 CHANNEL DSO HMO1524/HMO2024
2 GSa/s Real Time, Low Noise Flash A/D Converter (Reference Class)
oom up to 50,000:1
2 MPts Memory,
MSO (Mixed Signal Opt. HO3508) with 8 Logic Channels
Serial Bus Trigger and Hardware accelerated Decode including List View.
Options: I2C + SPI + UART/RS-232 (HOO10/HOO11), CAN + LIN (HOO12)
Automatic Search for User defined Events
Pass/Fail Test based on Masks
Vertical Sensitivity 1 mV/div., Offset Control ±0.2...±20 V
Display Range: 12 div. x-Axis, 20 div. y-Axis (VirtualScreen)
Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
Component Tester, 6 Digit Counter, Automeasurement:
max. 6 Parameters incl. Statistic, Formula Editor, Ratiocursor, FFT: 64 kPts
Fan: Silence redefined
3 x USB for Mass Storage, Printer and Remote Control
70 MHZ/100 MHZ 2 CHANNEL DSO HMO722/HMO1022
5
5
5
5
300 / 400 / 500 MHZ 4 CHANNEL MSO HMO3004 SERIES
70 MHZ/100 MHZ 4 CHANNEL DSO HMO724/HMO1024
2 GSa/s Real Time, Low Noise Flash A/D Converter (Reference Class)
oom up to 50,000:1
2 MPts Memory,
MSO (Mixed Signal Opt. HO3508) with 8 Logic Channels
Serial Bus Trigger and Hardware accelerated Decode including List View.
Options: I2C + SPI + UART/RS-232 (HOO10/HOO11), CAN + LIN (HOO12)
Automatic Search for User defined Events
Pass/Fail Test based on Masks
Vertical Sensitivity 1 mV/div.
Display Range: 12 div. x-Axis, 20 div. y-Axis (VirtualScreen)
Trigger Modes: Slope, Video, Pulsewidth, Logic, Delayed, Event
Component Tester, 6 Digit Counter, Automeasurement:
max. 6 Parameters incl. Statistic, Formula Editor, Ratiocursor, FFT: 64 kPts
Fan: Silence redefined
3 x USB for Mass Storage, Printer and Remote Control
* Serial Bus HOO10: I2C/SPI/UART/RS-232 on Logic Channels and Analog Channels
Serial Bus HOO11: I2C/SPI/UART/RS-232 on Analog Channels
Serial Bus HOO12: CAN/LIN on Logic Channels and Analog Channels
E
Elektronik
Product of the Year
2012
HMO1024
No. 1 in Category
Test + Measurement
PDF Compressor Pro
HOO10/HOO11/HOO12 SERIAL BUS TRIGGER & DECODE OPTIONS
FOR ALL OSCILLOSCOPES OF THE HMO SERIES
5 HOO10 I2C, SPI, UART/RS-232 Bus Trigger and Decode via Analog and
Logic Channels
5 HOO11 I2C, SPI, UART/RS-232 Bus Trigger and Decode via Analog Channels
5 HOO12 CAN, LIN Bus Trigger and Decode via Analog and Logic Channels
5 Hardware accelerated Decode in Realtime
5 Color Coded Display of the Content for intuitive Analysis and easy Overview
5
5
5
5
5
5
1.6 GHZ [3 GHZ] SPECTRUM ANALYZER HMS1000 [HMS3000]
1.6 GHZ SPECTRUM ANALYZER HMS1000E
5 Frequency Range 100 kHz…1.6 GHz [3 GHz]
5 Tracking Generator HMS1010 [HMS3010] -20…0 dBm
5 Amplitude Measurement Range -114…+20 dBm
DANL -135 dBm with Preamp. Option HO3011
5 Sweep Time 20 ms…1,000s
5 Resolution Bandwidth 100 Hz…1 MHz in 1–3 Steps,
200 kHz (-3 dB); additional 200 Hz, 9 kHz, 120 kHz, 1 MHz (-6 dB)
5 Spectral Purity <-100 dBc/Hz (@100 kHz)
5 Video Bandwidth 10 Hz…1 MHz in 1–3 Steps
5 Integrated AM and FM Demodulators (Phone and int. Speaker)
5 Detectors: Auto-, Min-, Max-Peak, Sample, RMS, Quasi-Peak
5 8 Markers with Delta Marker, miscellaneous Peak Functions
5
5
5
5
5
5
5
5
5
5
5
HO3011 PREAMPLIFIER
HZ540/HZ550 [HZ530] NEAR FIELD PROBES SET 3GHZ [1GHZ]
FOR SPECTRUM ANALYSER OF THE HMS SERIES
More Details of the decoded Values come visible with increasing Zoom Factor
Bus Display with synchronous Display of the Data and maybe Clock Signal
Decode into ASCII, Binary, Hexadecimal or Decimal Format
List View of all decoded Messages
Powerful Trigger to isolate specific Messages
Option for all Oscilloscopes of the HMO Series, retrofittable
Frequency Range 100 kHz…1.6 GHz
Amplitude Measurement Range -104…+20 dBm
Sweep Time 20 ms…1,000s
Resolution Bandwidth 10 kHz…1 MHz in 1–3 Steps, 200 kHz (-3 dB)
Spectral Purity <-100 dBc/Hz (@100 kHz)
Video Bandwidth 1 kHz…1 MHz in 1–3 Steps
Integrated AM and FM Demodulator (Phone and int. Speaker)
Detectors: Auto-, Min-, Max-Peak, Sample, RMS
8 Markers with Delta Marker, miscellaneous Peak Functions
Crisp 16.5 cm (6.5") TFT VGA Display
3 x USB for Mass-Storage, Printer and Remote Control,
optional IEEE-488 (GPIB) or Ethernet/USB Dual-Interface
The HZ540/550 are the ideal toolkits for the
investigation of RF electromagnetic fields.
They are indispensable for EMI pre-compliance testing during product development, prior to third party testing. The sets
include 3 or 5 hand-held probes with builtin pre-amplifier covering the frequency
range from <1MHz to approx. 3,000MHz.
1GHz:
HZ530
5 Preamplifier Option for HMS1000, HMS1010, HMS3000, HMS3010 (Licence Key)
5 DANL -135dBm typ. (100Hz RBW)
The probes of the basic set HZ540 include
one magnetic field probe, one electric field
probe, and a high impedance probe. In
addition to the HZ550 features an optional
µ-magnetic field probe and a passive radiation probe. All probe outputs are matched
to the 50Ω inputs of spectrum analyzers or
RF-receivers.
The HZ530 Probe Set consists of three active broadband probes for EMI diagnosis. The probes are designed for connection to a HAMEG spectrum analyzer with
input impedance of 50 Ω. The probes can be powered by the spectrum analyzer or
batteries. The slim format ensures easy access to the test object even in cramped
test environments.
PDF Compressor Pro
LINE IMPEDANCE STABILIZATION NETWORK HM6050-2
8KW POWER METER HM8115-2
opt.
HZ815
5 115 V and 230 V versions available
5 Measurement of Line-conducted Interferences
within the Range from 9 kHz…30 MHz (CISPR 16)
5 Selectable Transient Limiter
5 Artificial Hand Connector
5
5
5
5
5
5
5
5
5
PROGR. 3 [4] CHANNEL POWER SUPPLY HMP4030 [HMP4040]
PROGR. 2 [3] CHANNEL POWER SUPPLY HMP2020 [HMP2030]
5 3 x 0…32 V/0…10 A 384 W max.
[4 x 0…32 V/0…10 A 384 W max.]
5 384 W Output Power realized by intelligent Power Management
5 Low Residual Ripple: <150 µVrms due to linear Post Regulators
5 High Setting- and Read-Back Resolution of 1 mV up to 0.2 mA
5 Keypad for direct Parameter Entry
5 Galvanically isolated, earth-free and short circuit protected Output Channels
5 Advanced Parallel- and Serial Operation via V/I Tracking
5 EasyArb Function for freely definable V/I Characteristics
5 FuseLink: Individual Channel Combination of Electronic Fuses
5 Free adjustable Overvoltage Protection (OVP) for all Outputs
5 All Parameters clearly displayed via LCD and Illuminated Buttons
5 Rear Connectors for all Channels including Sense
5 USB/RS-232 Dual-Interface, optional Ethernet/USB Dual-Interface or
IEEE-488 (GPIB)
5 1 x 0…32 V/0…10 A
1 x 0…32 V/0…5 A
188 W max.
[3 x 0…32 V/0…5 A
188 W max.]
5 188 W Output Power realized by intelligent Power Management
5 Low Residual Ripple: <150 µVrms due to linear Post Regulators
5 High Setting- and Read-Back Resolution of 1 mV up to 0.1 mA
5 Galvanically isolated, earth-free and short circuit protected
Output Channels
5 Advanced Parallel- and Serial Operation via V/I Tracking
5 EasyArb Function for free definable V/I Characteristics
5 FuseLink: Individual Channel Combination of Electronic Fuses
5 Free adjustable Overvoltage Protection (OVP) for all Outputs
5 All Parameters clearly displayed via LCD/Glowing buttons
5 Rear Connectors for all Channels including Sense
5 USB/RS-232 Dual-Interface, optional Ethernet/USB or IEEE-488 (GPIB)
ARBITRARY POWER SUPPLY HM8143
TRIPLE POWER SUPPLY HM7042 - 5
5
5
5
5
5
5
5
5
5
5
5
2 x 0…30 V/0…2 A
1 x 5 V/0…2 A
Display Resolution 10 mV/1 mA
Parallel (up to 6 A) and Serial (up to 65 V) Operation
Electronic Load up to 60 W per Channel (max. 2 A)
Arbitrary Waveform Power Supply (4,096 Points, 12 Bit):
Creation of customized Waveforms
Free of charge Software for Remote Control and for Creation of Arbitrary
Waveforms
Electronic Fuse and Tracking Mode for 30 V Outputs
External Modulation of Output Voltages:
Input Voltage 0…10 V, Bandwidth 50 kHz
SENSE Lines for Compensation of the Voltage drop across the Cables
Multimeter Mode for all adjustable Outputs
Galvanically isolated USB/RS-232 Dual-Interface, optional IEEE-488 (GPIB)
5
5
5
5
5
5
5
5
5
5
Wide Measurement Range 1 mW…8 kW
Voltage Range 100 mV…500 V, Current Range 1 mA…16 A
Frequency Range DC…1 kHz
Simultaneous Display of Voltage, Current and Power
Display of apparent, active and reactive Power
Power Factor Display
Autoranging for simple Operation
Monitor Output (BNC) representing the instantaneous Power
Suitable for Measurements on Frequency Converters
2 x 0…32 V/0…2 A
1 x 0…5,5 V/0…5 A
High-Performance and inexpensive Laboratory Power Supply
Floating, overload and short-circuit proof Outputs
Separate Voltage and Current Displays for each Output
4 Digits at Channel 1+3; 3 Digits at Channel 2
Display Resolution:
10 mV/1 mA at Channel 1+3; 10 mV/10 mA at Channel 2
Protection of sensitive Loads by Current Limit or Electronic Fuse
Pushbutton to activate /deactivate all Outputs
Low Residual Ripple, high Output Power, excellent Regulation
Parallel (up to 9 A) and Series (up to 69.5 V) Operation
Temperature-controlled Fan
PDF Compressor Pro
25 [ 50 MHZ] ARBITRARY FUNCTION GENERATOR HMF2525 [HMF2550]
200 KHZ LCR - BRIDGE HM8118
incl.
HZ188
5
5
5
5
5
5
5
5
5
5
5
5
Frequency Range 10 µHz…25 MHz [50 MHz]
Output Voltage 5 mVpp…10 Vpp (into 50 Ω) DC Offset ±5 mV…5 V
Arbitrary Waveform Generator: 250 MSa/s, 14 Bit, 256 kPts
Sine, Square, Pulse, Triangle, Ramp, Arbitrary Waveforms
incl. Standard Curves (white Noise, Cardiac etc.)
Total Harmonic Distortion 0.04 % (f <100 kHz)
Burst, Sweep, Gating, external Trigger
Rise Time <8 ns, in Pulse Mode 8…500 ns Variable-Edge-Time
Pulse Mode: Frequency Range 100 µHz…12.5 MHz [25 MHz],
Pulse Width 15 ns…999 s, Resolution 5 ns
Modulation Modes AM, FM, PM, PWM, FSK (int. and ext.)
10 MHz Timebase: ±1 ppm TCXO, rear I/O BNC Connector
Front USB Connector: Save and Recall of Waveforms and Settings
8.9cm (3.5") TFT: crisp Representation of the Waveform and all Parameters
6½ - DIGIT PRECISION MULTIMETER HM8112 -3 [HM8112 -3S]
5
5
5
5
5
5
5
5
5
5
5
5
6½-Digit Display (1,200,000 Counts)
Resolution: 100 nV, 100 pA, 100 µΩ, 0.01 °C/F
DC Basic Accuracy 0.003 %
2-Wire/4-Wire Measurements
Measurement Intervals adjustable from 0.1…60 s
Up to 100 Measurements per Second transmitted to a PC
True RMS Measurement, AC and DC+AC
Mathematic Functions: Limit Testing, Minimum/Maximum,
Average and Offset
Temperature Measurements with Platinum (PT100/PT1000) and Ni (K and J
types) Sensors
Internal Data Logger for up to 32,000 Measurement Results
Offset Correction
Galvanically isolated USB/RS-232 Dual-Interface, optional IEEE-488 (GPIB)
5
5
5
5
5
5
5
5
5
5
5
Basic Accuracy 0.05 %
Measurement Functions L, C, R, |Z|, X, |Y|, G, B, D, Q, O, ∆, M, N
Test Frequencies 20 Hz…200 kHz
Up to 12 Measurements per Second
Parallel and Serial Mode
Binning Interface HO118 (optional) for automatic Sorting of Components
Internal programmable Voltage and Current Bias
Transformer Parameter Measurement
External Capacitor Bias up to 40 V
Kelvin Cable and 4-Terminal SMD Test Adapter included
Galvanically isolated USB/RS-232 Dual-Interface,
optional IEEE-488 (GPIB)
12.5 MHZ ARBITRARY FUNCTION GENERATOR HM8150
5 Frequency Range 10 mHz…12.5 MHz
5 Output Voltage 10 mVpp…10 Vpp (into 50 Ω)
5 Waveforms: Sine Wave, Square Wave, Triangle, Pulse,
Sawtooth, Arbitrary
5 Rise and Fall Time <10 ns
5 Pulse width Adjustment: 100 ns…80 s
5 Arbitrary Waveform Generator 40 MSa/s
5 Burst, Gating, External Triggering, Sweep
5 Free of charge Software for Remote Control and for Creation of
Arbitrary Waveforms
5 External Amplitude Modulation (Bandwidth 20 kHz)
5 Intuitive Operation with one touch of a Button – quick Change of Signals
5 Galvanically isolated USB/RS-232 Dual-Interface, optional IEEE-488 (GPIB)
3 GHZ PROGRAMMABLE COUNTER HM8123
1.2 GHZ [3 GHZ] RF- SYNTHESIZER HM8134-3 [HM8135]
5 Measurement Range 0 Hz…3 GHz
5 2 Measurement Inputs DC…200 MHz,
1 Measurement Input 100 MHz…3 GHz
5 Input Impedance A/B: 1 MΩ/50 Ω (switchable), Sensitivity 25 mVrms
5 Input Impedance C: 50 Ω, Sensitivity 30 mVrms
5 400 MHz Time Base with 0.5 ppm Stability
5 10-Digit Resolution at 10 s Gate Time
5 9 Measurement Functions, external Gate and Arming
5 Input for external Time Base (10 MHz)
5 Standard: TCXO (Temperature Stability: ±0.5 x 10 -6)
Optional: OCXO (Temperature Stability: ±1 x 10 -8)
5 Intuitive One-Pushbutton Operation, each Function directly selectable
5 Galvanically isolated USB/RS-232 Dual-Interface, optional IEEE-488 (GPIB)
5
5
5
5
5
5
5
5
5
5
5
Frequency Range 1 Hz…1.2 GHz [3 GHz]
Output Power -127…+13 dBm [-135…+13 dBm]
Frequency Resolution 1 Hz (Accuracy 0.5 ppm)
Input for external Time Base (10 MHz)
Modulation Modes: AM, FM, Pulse, \, FSK, PSK
Rapid Pulse Modulation: typ. 200 ns
Internal Modulator (Sine Wave, Square Wave, Triangle, Sawtooth)
10 Hz…150 kHz [200 kHz]
High spectral Purity
10 Configuration Memories including Turn-On Configuration
Standard: TCXO (Temperature Stability: ±0.5 x 10 -6)
Optional: OCXO (Temperature Stability: ±1 x 10 -8)
Galvanically isolated USB/RS-232 Dual-Interface, optional IEEE-488 (GPIB)
PDF Compressor Pro
+++ HAMEG MODULAR SYSTEM SERIES 8000 +++ HAMEG MODULAR SYSTEM SERIES 8000 +++ HAMEG MODULAR SYSTEM SERIES 8000 +++
4¾ -Digit Programmable
Multimeter HM8012
LCR-Meter
HM8018
1.6 GHz Universal
Counter HM8021-4
10 MHz Function
Generator HM8030-6
Triple Power Supply
HM8040-3
In many years of practical application the HAMEG Modular System Series 8000 has proven its value to the customer.
The advantages of this Modular System have been demonstrated by several 100,000 modules sold. The unexcelled
price-performance ratio and the enormous flexibility of the plug-in system allow you to adapt your measurement
setups quickly and cost effectively to changing requirements. The mainframe allows the simultaneous operation of
two modules.
Blank Module HM800
Mainframe HM8001-2
HO730 DUAL ETHERNET/USB INTERFACE
HZ547 VSWR BRIDGE 3 GHZ
This unit is used to measure the
voltage standing wave ratio
(VSWR) and the reflection
coefficient of a device under test
with an impedance of 50 Ω.
Frequency range:
Impedance:
Directivity:
5
5
5
5
Ethernet 10 /100 MBit/s
5 Additionally integrated Web Server
Screenshot Function using Web Server
USB 2.0 Standard, USB Type B Connector
For mounting into Oscilloscopes HM1008, HM1508, HM1008-2, HM1500-2,
HM1508-2, HM2005-2, HM2008, Series HMF, HMO, HMP and HMS
100 kHz…3 GHz
50 Ω
>28 dB (100…300 kHz)
>35 dB (300 kHz…1 GHz)
>30 dB (1…3 GHz)
Reflection loss at DUT port: >20 dB
Insertion loss
IN t OUT:
20 dB (100…300 kHz)
IN t OUT:
18 dB (300 kHz…3 GHz)
IN t DUT:
1.7 dB
DUT t OUT:
16 dB
Max. Power Dissipation:
+26 dBm
Connectors:
N (female)
Dimensions:
150 x 68 x 29.5 mm (W x H x D), without connectors
Weight:
approx. 650 g
Temperature range:
+10…+ 45 °C
Accessories supplied:
HZ525 (Termination 50 Ω 1 W), N male to N male
(2 pcs.), Carrying case (265 x 225 x 50 mm W x H x D)
5 24-pin Connection in Accordance with IEEE-488 (GPIB) (Socket)
5 Galvanic Separation of Test Device and Interface
5 For mounting into Oscilloscopes HM1008, HM1508, HM1008-2, HM1500-2,
HM1508-2, HM2005-2, HM2008, Series HMF, HMO, HMP and HMS
HZ10 SILICONE TEST LEAD
HZO90/HZ99 CARRYING CASE
Silicone test lead with stackable
banana plugs.
Length:
1.0 m
Packaging unit:
set of 5
HZ10R
color: red
HZ10B
color: blue
HZ10S
color: black
HZ24 SET OF ATTENUATORS 50 Ω
We recommend the HZ99 Carrying Case
for protection and transport of oscilloscopes
(HMO2524, HMO352x) and spectrum analyzers (HMS series), the HZO90 Carring Case
for protection and transport of HMO72x…
HMO202x. The instruments can be transported conveniently and safely in the case.
HZ815 POWER ADAPTER
One set of 50 Ω attenuators with 3/6/10/20 dB
attenuation (1 GHz, 1 Watt) and 1HZ22.
Packaging unit:
HO740 IEEE-488 (GPIB) INTERFACE
1 set
HZ181 4 TERMINAL TEST FIXTURE INCLUDING SHORTING PLATE
4 Terminal Test Fixture including Shorting
Plate (for HM8118) for evaluation of lead type
devices.
HZ186 4 TERMINAL TRANSFORMER TEST CABLE
4 Terminal Transformer Test Cable (for HM8118)
for transformer measurements.
FOR HM8115-2
Adapter for simplified measurement of power
consumption, line voltage and current consumption of mains operated gear (3-wire
safety plug or European standard plug) using
the HM8115-2 Power Meter.
HO3508 [HO3516] LOGIC PROBE
FOR HMO SERIES
5 Logic Probe HO3508 for MSO Extension, also available
in a double Package as HO3516 (2 x HO3508)
5 With the Logic Probe HO3508, 8 Logic Channels
(LCH 0…LCH 7 or LCH 8…LCH 15) are available
in MSO Mode
5 The Display on the Oscilloscope will be either as
individual Channels or as a Bus Display
5 Decoding may be in the ASCII, Binary, Decimal or
Hexadecimal Formats
5 The Threshold can be adjusted for 8 Logic Channels
as a Group at the Oscilloscope
5 The Activation of the Logic Channels is indicated by a LED on the Logic Probe
PDF Compressor Pro
HZ154 1:1/10:1 10/100MHZ PROBE
HZO10 10:1 250MHZ PROBE
Attenuation ratio: 1:1
Switchable:
10:1
Bandwidth:
10 / 100MHz
Rise time :
<35 / 3.5ns
Input impedance: 1 / 10 MΩ II 82 / 12 pF
Max. voltage:
(10:1) 600 V
(DC + peak AC)
HZ350 10:1 350MHZ PROBE
Attenuation ratio:
Bandwidth:
Rise time:
Input impedance:
Max. Voltage:
10:1
250 MHz
<1,4 ns
10 MΩ II 15 pF
400 V
(DC + peak AC)
Measuring category: CAT I
HZ355 10:1 500MHZ PROBE
Attenuation ratio: 10:1
Bandwidth:
350 MHz
Rise time:
<1.0 ns
Input impedance: 10 MΩ II 12 pF
Max. Voltage:
400 V (DC + peak AC)
Probe factor identification:
automatically after plugging
HZO20 1,000:1 HIGH VOLTAGE PROBE
HZO50/HZO51 AC/DC CURRENT PROBES
Attenuation ratio: 1,000:1
Bandwidth:
400 MHz
Rise time:
<900 ps
Input impedance: 50 MΩ II 7.5 pF
Max. Voltage:
1,000 Vrms
Probe factor identification:
automatically after plugging
HZO30 1GHZ ACTIVE PROBE
Attenuation ratio: 10:1
Bandwidth:
1 GHz
Rise time:
600 ps
Input impedance: 1 MΩ II 0.9 pF
Max. Input voltage: 20 V
Input Dynamic Range: ±8 V
Oscilloscope Input Coupling: 50 Ω
HZO40/HZO41
Attenuation ratio: 10:1
Bandwidth:
500 MHz
Rise time:
<700 ps
Input impedance: 10 MΩ II 9.5 pF
Max. Voltage:
400 V (DC + peak AC)
Probe factor identification:
automatically after plugging
HZO50
Measurement range:
Accuracy:
Bandwidth:
Resolution:
Output voltage:
Load impedance:
Max. Voltage:
HZO51
±20 A rms /30 A p
±1 % / ±2 mA
DC…100 kHz (0.5 dB)
±1 mA
100 mV / A
› 100 kΩ II ≤ 100 pF
300 Vrms (AC or DC)
±100 A rms / 1,000 A rms
±1 % / ±0.1 A / ±0.5 A
DC…20 kHz
±100 mA / ±500 mA
10 mV / A / 1mV / A
› 100 kΩ II ≤ 100 pF
300 Vrms (AC or DC)
HZ42, HZ43, HZ45, HZ46, HZO91, HZP91 19“ RACKMOUNT KIT
Zum Einbau der HAMEG Geräte
DIFFERENTIAL PROBES 10:1
Bandwidth:
Attenuation ratio:
Rise time (10…90 %):
Gain accuracy:
Max. Input Voltage
per Input:
Max. Differential Input
Voltage (DC + peak AC):
Max. Common Mode
Input Voltage:
Input impedance
Between Inputs:
Each Input to Ground:
Output Voltage
(into 50 Ω):
Offset (typical):
CMRR (typical):
Battery operation:
Battery life (typical):
HZO40
200 MHz
10:1
1.75 ns
±1 %
HZO41
800 MHz
10:1
437 ps
±2 %
±60 V
±40 V
±20 V
±15 V
±60 V
±30 V
1 MΩ II 3.5 pF
500 kΩ II 7 pF
200 kΩ II 1 pF
100 kΩ II 2 pF
±2 V
±2 mV
-80 dB at 60 Hz
-50 dB at 10 MHz
9 V battery 6LR61
7.5 h
±1.5 V
±5 mV
-60 dB at 60 Hz
-15 dB at 500 MHz
9 V battery 6LR61
4.5 h
HZ115 100:1/1,000:1 DIFFERENTIAL PROBE
Differential input voltage (ACrms): 1,000V
(DC + peak AC) max.:
±1,400V
Max. input voltage per input:
±1,400V
Attenuation ratio:
100:1
Switchable:
1,000:1
Bandwidth:
20/30MHz
Rise time:
17/12ns
Input impedance:
60MΩ II 1.5pF
Output impedance: 50Ω
Max. output voltage: ±1.5V at 1MΩ
Accuracy after 1min: ±3% (18…30°C)
Common mode rejection
DC/AC 1MHz:
70dB/›50dB
Inputs (CAT III): 2 safety connectors
Battery operation: 9V battery 6LR61
HZ42 2 RU:
88 mm
Dimensions (W x D):
440 x 360 mm plus overhang of the instrument
(for Series 8100, HM8143, HM7042-5, HM8001-2, HMP2020, HMP2030
and HMF Series) Case height 75 mm
HZ43 3 RU:
132.5 mm
Dimensions (W x D):
440 x 360 mm plus overhang of the instrument
(for HM2005, HM303-6, HM504-2, HM507, HM5510, HM5014-2, HM5530,
HM6050-2, HM7044, HMP4030, HMP4040) Case height 125 mm
HZ45 4 RU:
177 mm
Dimensions (W x D):
440 x 360 mm plus overhang of the instrument
(for HM400, HM1000, HM1000-2, HM1008, HM1008-2, HM1500, HM1500-2,
HM1508, HM1508-2, HM2005-2, HM2008) Case height 125 mm
HZ46 4 RU:
177 mm
Dimensions (W x D):
440 x 170 mm plus overhang of the instrument
(for HMO352X, HMO2524 and HMS Series) Case height 175 mm
HZO91 4 RU:
177 mm
Dimensions (W x D):
440 x 110 mm plus overhang of the instrument
(for HMO72X, HMO102X, HMO152X, HMO202X) Case height 175 mm
HZP91 4 RU:
Dimensions (W x D):
177 mm
440 x 360 mm plus overhang of the instrument
(for HMP4030, HMP4040) Case height 125 mm
www.hameg.com | blog.hameg.com
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement