Dell PowerConnect B-DCX-4s Replacement Procedure


Add to my manuals

advertisement

Dell PowerConnect B-DCX-4s Replacement Procedure | Manualzz

53-1001794-01

January 31, 2010

Power Supply and Filler

Panel

Replacement Procedure

Supporting PowerConnect B-DCX-4S Backbone and PowerConnect B-DCX

Backbone

53-1001794-01

*53-1001794-01*

Notes, Cautions, and Warnings

NOTE

A NOTE indicates important information that helps you make better use of your computer.

CAUTION

See the safety and regulatory information that shipped with your system. For additional regulatory information, see the Regulatory Compliance Homepage on www.dell.com at the following location: www.dell.com/regulatory_compliance.

CAUTION

A CAUTION indicates potential damage to hardware or loss of data if instructions are not followed.

DANGER

A DANGER indicates a potential for property damage, personal injury, or death.

____________________

Information in this document is subject to change without notice.

© 2009 Dell Inc. All rights reserved.

Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.

Trademarks used in this text: Dell, the DELL logo, Inspiron, Dell Precision, Dimension, OptiPlex, Latitude, PowerEdge, PowerVault, PowerApp, Dell

OpenManage and the YOURS IS HERE logo are trademarks of Dell Inc.; Intel, Pentium, and Celeron are registered trademarks of Intel Corporation in the U.S. and other countries; Microsoft, Windows, Windows Server, MS-DOS and Windows Vista are either trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.

Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.

Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.

Regulatory Model Codes: Brocade DCX-4S, Brocade DCX

2 Power Supply and Filler Panel Replacement Procedure

53-1001794-01

In this guide

Power supply installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Time and items required . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Removing a power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Replacing a power supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Power supply installation

Use this procedure to remove and replace a power supply.

NOTE

The PowerConnect B-DCX can continue operating during the replacement if:

At least one 220 VAC power supply is operating,

At least two 110 VAC power supplies are working.

The PowerConnect B-DCX-4S can continue operating during the replacement if the second 220 VAC power supply is operating,

Time and items required

The replacement procedure for each power supply takes less than 5 minutes. A power supply unit or filler panel is required for the power supply replacement.

Figure 1 shows the location and identification of the power supplies for the PowerConnect B-DCX.

1 Power supply 1 (PS1)

2 Power supply 2 (PS2)

3 Power supply 3 (PS3)

4 Power supply 4 (PS4)

FIGURE 1

Power supply identification for the PowerConnect B-DCX

Power Supply and Filler Panel Replacement Procedure

53-1001794-01

3

Figure 2 shows the location and identification of the power supplies for the PowerConnect B-DCX-4S.

4

1 Power supply 1 (PS1) 2 Power supply 2 (PS2))

FIGURE 2

Power supply identification for the PowerConnect B-DCX-4S

Removing a power supply

1. Perform one of the two following tasks:

For the PowerConnect B-DCX:

• If the PowerConnect B-DCX is not operating during the replacement procedure, go to step 2.

• If the PowerConnect B-DCX is operating and will continue to operate during the replacement, check the power LEDs to verify that the minimum number of power supplies is functioning. A fully populated

PowerConnect B-DCX requires a minimum of one power supply at all times.

For the PowerConnect B-DCX-4S:

• If the PowerConnect B-DCX-4S is not operating during the replacement procedure, go to step 2.

• If the PowerConnect B-DCX-4S is operating and will continue to operate during the replacement, check the power LEDs to verify that the minimum number of power supplies is functioning. A fully populated

PowerConnect B-DCX-4S requires a minimum of one power supply at all times.

2. Turn off the power switch.

3. Remove the power cord.

4. Loosen the thumb screw on the right side of the power supply.

Power Supply and Filler Panel Replacement Procedure

53-1001794-01

5. Grasp the handle and pull, sliding the power supply from the chassis and supporting the power supply from

beneath as you remove it ( Figure 3 or Figure 4

).

6. If you are not replacing the power supply, insert a filler panel into the slot.

FIGURE 3

Power supply for the PowerConnect B-DCX

FIGURE 4

Power supply for the PowerConnect B-DCX-4S

Power Supply and Filler Panel Replacement Procedure

53-1001794-01

5

Replacing a power supply

1. Remove any filler panel.

2. Insert the power supply into the slot and push the handle up. Verify that the power supply is seated by gently pulling on the handle .

3. Tighten the thumb screw.

4. Replace the power cord.

5. Turn on the power switch.

6. Verify that the power LED on the power supply displays a steady green light.

6 Power Supply and Filler Panel Replacement Procedure

53-1001794-01

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Up to 4 Gigabit Ethernet ports
  • Power over Ethernet (PoE) support
  • Advanced security features
  • Easy to manage and configure
  • Compact and affordable

Related manuals

Frequently Answers and Questions

What is the maximum number of Gigabit Ethernet ports that the Dell B-DCX-4s can support?
The Dell B-DCX-4s can support up to 4 Gigabit Ethernet ports.
Does the Dell B-DCX-4s support Power over Ethernet (PoE)?
Yes, the Dell B-DCX-4s supports Power over Ethernet (PoE).
What are some of the advanced security features that the Dell B-DCX-4s offers?
The Dell B-DCX-4s offers a variety of advanced security features, including access control lists (ACLs), firewall protection, and intrusion detection and prevention (IDS/IPS).

advertisement