Mini catalogue 2013
air curtains
” radiant
heaters
fan heaters
convectors
thermostats
Comfortable and energy efficient indoor climate.
Welcome
Welcome to the 2013 edition of the Frico Mini
Catalogue. We are proud to introduce a number
of news this year. Our new intelligent air curtain
range, the PA-series, is now complete and we
also present a number of improvements on our
other air curtain models. At our new website we
share our knowledge within heating and the new
product selection guide makes it easier for you
to select the right product.
Our goal, as the European market leader, is
to have the most energy-efficient, well designed
and installer friendly heating products on the
market. We hope this Mini Catalogue will be a
useful tool when choosing the correct product
for each application. For more extensive
product information, please visit www.frico.se.
Looking forward to hearing from you!
Pontus Grimberg
International Sales Manager
International Sales
Pontus Grimberg
Do not hesitate to contact us!
Mo - Fr 8.00 - 17.00 CET
T +46 31 336 86 00
F +46 31 26 28 60
[email protected]
Technical support
Björn Sandqvist
International Sales Manager
T: +46 31 336 86 35
F: +46 31 26 28 60
[email protected]
Adam Balogh
International Area Manager
T: +46 31 336 86 41
F: +46 31 26 28 60
[email protected]
Jan-Erik Lundholm
International Area Manager
T: +46 31 336 86 13
F: +46 31 26 28 60
[email protected]
Technical Support Manager
T: +46 31 336 86 14
F: +46 31 26 28 60
[email protected]
Martin Ekman
Technical Support
T: +46 31 336 86 34
F: +46 31 26 28 60
[email protected]
Peter Norrby
Technical Support
T: +46 31 336 86 57
F: +46 31 26 28 60
[email protected]
Sales support
Yvonne Stenholm
Sales Support Manager
T: +46 31 336 86 16
F: +46 31 26 28 60
[email protected]
Lena Majqvist
Sales Support
T: +46 31 336 86 38
F: +46 31 26 28 60
[email protected]
Ingvor Thomsson
Björklund
Susanne Andersson
Technical Support
T: +46 31 336 86 17
F: +46 31 26 28 60
[email protected]
Stephan Hansson
Quality Manager
T: +46 31 336 86 10
F: +46 31 26 28 60
[email protected]
Marketing and Sales
Coordinator
T: +46 31 336 86 06
F: +46 31 26 28 60
[email protected]
Managing director
Jonas Valentin
Managing Director
T: +46 31 336 86 04
F: +46 31 26 28 60
[email protected]
Cover: Restaurant L'Opera in Paris,
Palais Garnier. Photo: Roland Halbe
Frico’s air curtain creates a
comfortable indoor climate in the
opera houses restaurant where
guests can enjoy a unique atmosphere
created by the architect Odile Decq.
6
7
Air curtains
Thermozone technology
35
Radiant heaters
38 Thermoplus EC  3
12 Control system SIRe
39 Thermocassette HP  3
15 Door heater PA1006 3
39 Elztrip EZ100  3
15
PA1508 3
16 PA2200C 1 3 2
40 Elztrip EZ200  3
40 Elztrip EZ300  3
17
PA2500 3 2
41 Infrared heater IR  3
18
AD200 3 2 1
41 Infrared heater IRCF 3
59
59
60
Ceiling fans
Industrial ceiling fan ICF 3
Convectors
60
Benchheater SH  3
60
Frostguard FML  3
61
Ribbed pipe radiator  3
61
Thermowarm TWT, TWTC   3
62
Fan convector PF 3 2
19 Portier 1 3
42 Infrared heater CIR 3
20 ADA 1
42 Infrared heater ELIR 3
20 ADA Cool 1
43 Infrared heater IH 3
63
Room thermostats T, TK, TD
21 AR200, recessed 1 3 2
44 Comfort Panel SZR,
water heated, recessed 2
63
2-step room thermostats RTI2,
RTI2V
45 Comfort Panel SZ,
64
Capillary tube thermostats KRT
64
Bimetal thermostats TBK
64
Timer CBT, digital time switch
KUR
65
Water controls VOS, VOSP, VOT,
VMO, VMOP, VMT
66
Water controls VR20/25,
TVV20/25, SD20
22
AR300, recessed 3 2
23
AR3500, recessed 1 3 2
24
Corinte ADCS 1 3 2
24
Corinte ACCS 3 2
26 PA3500 1 3 2
water heated 2
46 Controls ERP, CIRT, S123
47
Fan heaters
26
PA4200 1 3 2
48 Door heater PA1006
29
AD300 1 3 2
48 K21, 2 kW  3
30
RDS,
for circular/revolving doors 3 2
49 Tiger,
2-9 kW, 15 kW, 20 and 30 kW  3
30
SFS
for circular/revolving doors 3 2
50 Elektra C/F/V/H   3
31 AGS5000 1 2
67
Thermostats and controls
Technical guide
51 Cat, 3-9 kW  3
31
AGS6000 1 2
52 Panther,
6-15 kW, 20 and 30 kW  3
32
AC500 1
54 SWH, water heated 2
32
UF600 1
57 SWS, water heated 2
33
AGI 1 2
58
34 Controls CB, ADSR54, RTRD
63
SWT, ceiling mounted,
waterheated 2
Design and specifications are
subject to change without notice.
See www.frico.se for latest
updated info.
Frico products
Today’s high and increasing energy prices often make heating costs substantial. Frico strives to develop products
and systems that provide energy saving heating solutions and better heating comfort at the same time. Reducing
energy losses and making optimum use of the heat is also important. Air curtains in doorways and openings,
radiant heaters or ceiling fans where the ceiling is high are examples of products that contribute to large energy
savings.
Air curtains
It makes sound economic sense to create an
efficient and invisible door that keeps the heat
inside. Air curtains can be even more effective
when used in air conditioned or cold storage
buildings.
Thermozone technology with its precisely
adjusted air velocity gives even protection
throughout the opening. Frico air curtains
provide the most efficient separation with the
lowest possible energy consumption, regardless
of whether it is the heat or the cold that you
want to keep inside.
Fan heaters
We are proud of the worldwide fame Frico fan heaters
have gained. They are reliable and are designed for long
life. Our range covers all needs. The investment cost is
low compared to other heating systems.
A great advantage of fan heaters is the option of
combining heating and ventilation. Frico fan heaters are
compact, silent and light weight. They are available for
electrical heating as well as for water heating.
Radiant heaters
Frico radiant heaters imitate the sun, the most
comfortable and efficient heat source available. The
heat is emitted only when the rays hit a surface and the
room temperature can thus be lowered while occupants
experience a comfortable environment. This makes
radiant heaters well suited not only for total heating
but also for zone and spot heating, for example to avoid
cold draughts from windows.
Radiant heaters are easy to install and require
minimum maintenance. They heat directly when
switched on and give no air movement.
Convectors
Convection is the term for the rotating air movement
where the air is affected by a heat source. The air
is heated - rises upwards - cools and comes back to
then be reheated. This gives good comfort through
good heat distribution and the warm air flow directed
upwards can be used to counteract cold drafts from
large glass surfaces.
Thermostats and controls
The key to energy efficient heating and good comfort
is the combination of heating products and good
controls. Frico offers a wide range of thermostats and
controls, read more under each product or in the Frico
Catalogues.
Ceiling fans
Ceiling fans force over-heated air from the
ceiling down to the occupation zone in
premises with high ceilings so that the heat is
maximally exploited.
More information
More information on Frico and Frico
products can be found on our website
www.frico.se, in our main catalogues
and other printed material that you can
order from us or from our distributors.
4
Good reasons to choose Frico
More than 75 years of experience of developing
products for the varied Nordic climate has provided us
with a unique knowledge bank. This is our foundation
when creating today's energy efficient solutions for a
comfortable indoor climate.
Leading technology and design
Since we develop our own products, our knowledge on how to
create an energy efficient indoor climate is constantly growing.
We have one of Europe's most modern and advanced air and
sound laboratories to aid us.
Qualified local support
Frico is present locally in some 70 countries worldwide with
a network of wholly-owned subsidiaries and independent
distributors. Our highly qualified representatives are carefully
chosen and together we are able to provide you with the best
possible support. To find your nearest Frico subsidiary or
distributor, please visit www.frico.se.
Frico Academy
Frico Academy is an important platform for networking
and sharing inspiration and knowledge between us and our
distributors around the world. Through the Frico Academy
we share our knowledge on theory and technology, as well
as product knowledge and experience in manufacturing and
product development.
Quality and long life
Frico offers consistent and high product quality. Our product
warranty is there for your safety. It covers manufacturing faults
and is valid for five years and necessary components will be
replaced.
Frico products are designed for long life and are easy to
maintain. Through our distribution network we provide
reliable maintenance and service support which includes the
availability of spare parts for at least ten years.
Frico saves energy
Thanks to our broad product range and our many years of
experience, Frico is able to help you save energy. By offering
total solutions, including both complete heating systems and
products for additional heating, we can generate a comfortable
indoor climate at a low energy cost. Our regulation systems
for different levels ensure that you never use more energy
than is required. Through our parent company, Systemair,
we also possess knowledge about ventilation and can provide
appropriate solutions.
Climate-smart
At Frico, we are proud to be able to offer energy-efficient
products for a better indoor climate. In our product
development work, the focus is on achieving the greatest
possible function with the least possible energy consumption –
without compromising on our core values of trust, competence
and design.
This means that our products not only manage the local
climate in business complexes, industrial buildings, offices or
summer cottages; with optimum energy efficiency, we ensure
that our products are climate-smart.
Frico's headoffice is located outside Gothenburg in
Sweden and we are a part of the Systemair Group.
Today Frico is represented in 70 countries world
wide either by subsidiaries or distributors. Updated
information is always available on our website
www.frico.se.
We manufacture at production units in
Skinnskatteberg, Sweden and at other ISO-certified
production units in Europe. Our warehouses are
strategically placed in several places in Europe.
5
Air curtains
Frico's Thermozone technology optimizes the air curtain
R
Frico air curtains create an invisible barrier at openings and doors which separates
different temperature zones without limiting access for people and vehicles. With
Thermozone Technology an efficient air separation is created in combination with a low
sound level, giving comfortable climate and large energy savings. Frico air curtains are
appreciated worldwide for their quality and operating efficiency, and are currently used in
over 70 countries.
Energy savings and good indoor climate
Design
In many premises, for example shops, department stores,
industrial premises and goods terminals, doors remain
open for a large part of the day. This means discomfort
for customers and staff at the same time as there are
significant losses of expensively heated or cooled air,
especially when the temperature difference between
outdoor and indoor air is great. Frico's air curtains give
a comfortable indoor climate, free from drafts, and the
losses of heated or cooled air are significantly reduced with
correctly installed air curtains. This means that the pay-off
time is reduced, especially for large door openings. The air
curtain also keeps out insects and emissions.
Frico collaborates with leading architects and product
designs in the product development. The air curtains
blends in well in the environment and the designed
for fit into both exclusive shop interiors as industrial
environments. With recessed installation the air curtains
become nearly invisible, only the outlet grille is visible.
Low sound level and high performance
Install and forget
With control system SIRe, the air curtain will always
perform at its best. You’ll never have to think about
switching it on or off. It even adapts to the season outside,
and with calendar function the air curtain automatically
runs during the hours it is needed.
Air curtains with Thermozone technology are developed
and manufactured in Frico's facility in Skinnskatteberg.
They are tested at one of the most modern and advanced
air and sound laboratories in Europe which means that we
can guarantee the data stated in our product information.
Thanks to the sophisticated equipment and our long
experience we can build air curtains with extremely low
noise levels and very high air flow performance.
[oC]
[oC]
[cm]
Opening
6
[cm]
[cm]
Opening
[cm]
Opening without air curtain
Opening with correctly adjusted air curtain
The heated or conditioned air escapes through this
unprotected opening. The result is energy loss and
poor comfort.
A sharp separation between different temperature zones is
obtained with a correctly set up air curtain. Thermozone
creates a barrier that effectively prevents undesired air
flows.
Air curtains
Thermozone technology
Frico’s air curtains have optimal curtain effect for doors
and entrances. Thanks to Thermozone technology,
performance can be precisely adjusted to obtain an air
curtain with efficient separation that is also comfortable to
pass through.
Thermozone technology creates the most
efficient air barrier.
Thermozone air curtains are optimized in:
• Airflow geometry
• Performance
• Sound level
Read more about Thermozone technology in our air
curtain catalogue and at www.frico.se.
Frico's outlet grilles generate an even
airflow that creates an efficient air barrier.
Air curtain experts
Frico knows air curtains. The company was founded in
1932 and we developed our first air curtains 40 year ago.
We are happy to share our knowledge and experience
and we are always available to help you choose the right
product.
By reducing the turbulence inside the air
curtain, the noise level is reduced.
Our air curtains
Type
Application
Recommended
installation height
PA1006
Door heater
-
Heat
Elec Water
Mounting
Extra
Horizontal
3
PA1508
Small openings
1,5 m
3
PA2200C
Entrances
2,2 m
3
2
PA2500
Entrances
2,5 m
3
2
AD200
Entrances
2,5 m
3
2
Portier
Entrances
2,5 m
3
ADA
Entrances
ADA Cool
Cold storage
AR200
Entrances
2,5 m
3
AR300
Commercial
3,5 m
AR3500
Commercial
3,5 m
Corinte
Commercial
PA3500
PA4200
Page
None
1
15
Horizontal
Cable and plug.
15
Horizontal
Remote control.
16
Horizontal
SIRe control system.
17
1
Horizontal
1
Horizontal
Brushed stainless steel.
19
2,5 m
1
Horizontal
Cable and plug.
20
2,5 m
1
Horizontal
Special terminales for easy connection of
several units. Cable and plug.
20
2
1
Horizontal
Recessed mounting.
21
3
2
1
Horizontal
Recessed mounting. Built-in control.
22
3
2
Horizontal
Recessed mounting. SIRe control system.
23
3m
3
2
1
Horizontal/Vertical
SIRe control system. Polished, mirror
polished or brushed stainless steel.
24
Commercial
3,5 m
3
2
1
Horizontal/Vertical
SIRe control system.
26
Commercial
4,2 m
3
2
1
Horizontal/Vertical
SIRe control system.
26
AD300
Commercial
3,5 m
3
2
1
Horizontal
RDS
Commercial
Revolving doors
3
2
SFS
Commercial
Revolving doors
3
2
Vertical
For revolving doors. SIRe control system.
30
AGS5000
Industry
5m
2
1
Horizontal
SIRe control system. Vertical unit is
available as special order.
31
AGS6000
Industry
6m
2
1
Horizontal
SIRe control system. Vertical unit is
available as special order.
31
AC500
Industry
5m
1
Horizontal/Vertical
UF600
Industry
Large doorways
1
Vertical
AGI
Industry
Large doorways
1
Horizontal/Vertical
2
Horizontal
18
29
For revolving doors. SIRe control system.
30
32
Air barrier blown from below
32
33
7
1
Choose air curtain
For optimal air curtain effect, it is important to choose the right air
curtain. We have air curtains for all openings from small kiosk hatches to
large industrial doors. They blow from above, from the side or from below.
Choose between electrical, water heated or unheated versions.
To get the most out of the product, the following hints are important to bear in mind.
• To ensure that the air flow reaches the floor at the optimal air speed, the installation height (not the
height of the opening ) determines the choice of air curtain.
• The air curtain units should cover the whole width (or height) of the opening. Thermozone can be
obtained in different lengths. For wide (high) openings, several units are mounted beside (on top) of
each other.
• The units should be positioned as close to the opening as possible.
• For optimal performance it is important that the pressure difference between outside and inside is
not too big.
Choose controls
In order to obtain the optimum comfort and energy efficiency,
it is important to choose the correct controls.
The vast majority of our air curtains are supplied with the SIRe
intelligent control system, which is built in and controls the
air curtain automatically. The air curtain adapts to the existing
conditions in the entrance. There are three different levels with
different functionality to choose from, Basic, Competent or
Advanced. Read more about SIRe on page 12-14.
The ADA, PA2200C and AR300 air curtains have Plug & play
controls; completely integrated controls that do not require any
external components. PA2200C also has a remote control. Read
more about Frico's other controls under the relevant air curtain
and on page 34.
For water heated air curtains, the control system must be
supplemented with a valve kit, see pages 65-66.
Choose accessories
3
Frico offers a range of mounting parts for the air curtains as
well as a number of other accessories that improve or simplify
installation and maintenance.
In this mini-catalogue, the accessories are shown together with
the relevant air curtains. You can also find the information in
the Product selection guide at www.frico.se.
8
2
Quick selection guide Frico air curtains
Horizontal mounting
The air curtains are mounted horizontally above the opening, creating a vertical air barrier.
Surface mounting
These air curtains can be mounted on a wall or in the
ceiling using threaded bars or cables.
Classic
Many of our models are classic
designs that blend in well in most
interiors.
Installation height
Air curtain
2,2 m
PA2200C 1 3 2
Page
16
2,5 m
PA2500 3 2
17
2,5 m
AD200 1 3 2
18
2,5 m
ADA 1
20
3,5 m
AD300 1 3 2
29
3,5 m
PA3500 1 3 2
26
4,2 m
PA4200 1 3 2
26
2,5 m
Portier 1 3
19
3m
Corinte 1 3 2
24
4,2 m
PA4200 1 3 2
26
5m
AGS5000 1 2
31
5m
AC500 1
32
6m
AGS6000 1 2
31
Large doorways
AGI 1 2
33
2,5 m
AR200 1 3 2
21
3,5 m
AR300 3 2
22
AR3500 1 3 2
23
Design
Our stainless steel air curtains are
design elements well suitable for
prestigious environments.
Industry
These robust and powerful units
are specifically designed for large
doorways.
Recessed mounting
These air curtains are installed recessed into
suspended ceilings with only the outlet grill visible.
Vertical mounting
The air curtains are mounted vertically next to the opening, creating a horizontal air barrier. Two air
curtains are installed, one on each side of the opening.
Classic
Design
Industry
Installation width*
Air curtain
5m
PA3500 1 3 2
Page
26
6m
PA4200 1 3 2
26
5m
Corinte 1 3 2
24
6m
PA42000 1 3 2
26
Large doorways
AGI 1 2
33
12 m
UF600 1
32
*) Two units, one on each side of the opening.
Air curtains for particular use
These air curtains are designed for a specific application area such as relvolving doors, service hatches or cold
storage.
The Product selection guide at
www.frico.se will give you further
assistance in selecting air curtains,
controls and accessories.
Application
Air curtain
Revolving doors
RDS 3 2
Page
30
SFS 3 2
30
Service hatches
PA1508 3
15
Door heater
PA1006 3
15
Cold storage
ADA Cool 1
20
1 Without heat 3 Elvectrical heat 2 Water heat
9
Air curtains
Installation examples for air curtains
Frico air curtains are available for openings of different
sizes and for different application areas. To facilitate your
choice of product, you will find some typical cases on the
following pages. More detailed information on important
factors to consider when choosing an air curtain is found on
the previous pages.
Please note that it is the installation height that is
decisive and not the height of the opening.
Basic criterias:
1.Type of premises: store, warehouse etc.
2.Height: installation height
3.Width: installation width
4.Mounting: horizontal or vertical
5.Connection: ambient, unheated (A), electrical (E), water
(W)
Shop
1. Type of premises: Shop
2. Installation height: 2,1 m
3. Installation width: 1 m
4. Mounting: Horizontal
5. Connection: Electrical
2,1 m
Recommendation: A PA2510E05 is recommended for
these conditions.
2,2 m
2m
1m
2. Installation height: 2,2 m
3. Installation width: 2 m
Recommendation: A shop with a large entrance and a lot of
traffic through the opening requires a larger unit to obtain a
comfortable climate. For these conditions we recommend a
PA3520E16.
Bank
1. Type of premises: Bank
2. Installation height: 2,2 m
3. Installation width: 2 m
4. Mounting: Horizontal or vertical
5. Connection: Water
Entrances
Recommendation: For an opening with high demands on
design and performance we recommend one or two AD
Corinte depending on the premises. AD Corinte can be
installed horizontally or vertically.
2,2 m
2m
2,2 m
2m
Cold room
Cold storage
1. Type of premises: Cold room
2. Installation height: 2,5 m
3. Installation width: 2,5 m
4. Mounting: Horizontal
5. Connection: Ambient
Recommendation: Two ADA Cool are recommended
for these conditions, mounted side by side above the
opening.
10
2,5 m
2,5 m
Air curtains
Shopping centre
1. Type of premises: Shopping centre
2. Installation height: 3 m
3. Installation width: 3 m
4. Mounting: Horizontal
5. Connection: Electrical
3m
Recommendation: Two PA3515E12 are
recommended for these conditions, mounted side
by side above the opening.
3m
Goods reception, grocery store
4m
Recommendation: Four vertically mounted
PA4220WL beside the opening, two at each side
are recommended for these conditions.
Commercial
1. Type of premises: Goods reception, grocery
store
2. Installation height: 4 m
3. Installation width: 4 m
4. Mounting: Vertical
5. Connection: Water
4m
Warehouse
1. Type of premises: Warehouse
2. Installation height: 5 m
3. Installation width: 4 m
4. Mounting: Horizontal
5. Connection: Water
5m
Recommendation: Two AGS5020WL are recommended for
these conditions, mounted side by side above the opening.
4m
Factory, heavy industry
Recommendation: For these conditions we recommend
UF600. Air is pressed out at high speed through a
narrow slot in the floor inside the opening. UF600
provides nearly 100 % protection against cold draughts
along the floor.
6m
Industry
1. Type of premises: Factory, heavy industry
2. Installation height: 6 m
3. Installation width: 4 m
4. Mounting: Vertical
5. Connection: Ambient
4m
11
Air curtains - Control system SIRe
The vast majority of our air curtains are supplied with the SIRe intelligent control
system, which is built in and controls the air curtain automatically. The air curtain adapts
to the existing conditions in the entrance. By sensing how often the door opens/closes,
outdoor temperature, indoor temperature or even the return water temperature, the air
curtain will give you the most effective protection with the highest energy efficiency.
Install and forget
With control system SIRe, the air curtain will always perform at its best. You’ll never have
to think about switching it on or off. It even adapts to the season outside, and with calendar
function the air curtain automatically runs during the hours it is needed.
Intelligent
BMS solutions
The air curtain automatically adapts to your
entrance conditions. Depending on how often
the door is opened/closed, or if it is left open
continually, the integrated SIRe controls the air
curtain operation so that optimal comfort and
energy efficiency is achieved.
With our intelligent control system SIRe, the
possibilities to control your air curtains via BMS
are endless. You can either choose to control
your air curtain by 0-10 V signals (controlling on/
off, fan speed, heating and alarm) or completely
control all functions and receive indications from
your air curtain via gateway (two threaded) BUS
communication.
Proactive
Simple installation
Anticipates for quicker reactions
”Plug and play”
By measuring the outdoor temperature, the air
curtain is always a step ahead. The integrated
regulation ensures that the air curtain is
prepared for changes in the outdoor temperature.
For example, when a warm spring day turns
into a chilly evening. The air speed is adjusted
depending on the outdoor temperature change
and stops the chill before it penetrates the
premises.
An air curtain with integrated SIRe control
system is easy to install. The different
components are supplied together and are
easy to assemble. The system self-checks that
everything is correct and that it functions.
Thanks to the preset default settings it is easy to
start air curtain operation as soon as the system
is in place.
Automatically adapts to your entrance
Adaptive
Expert on your entrance
SIRe has the capacity to learn precisely what
happens at your entrance. The air curtain adapts
so that it is always ready to operate fully as
soon as the door is opened. It also considers the
acoustic comfort by ensuring that the air curtain
does not switch between high and low speeds too
often.
Endless possibilities
Calendar function
Presets as required
SIRe has a calendar function for all the days of
the week. The air curtain starts in the morning
to ensure that it’s always working to create a
comfortable climate and save energy. Preset
default setting may easily be adjusted by the
user.
Eco mode
Regulation of airflow and
heat output
Save money and the environment at the
same time
With SIRe intelligent regulation integrated
in your air curtain, you get comfort in your
entrance without wasting energy. If you want to
increase the energy efficiency further, set SIRe
in Eco mode. The air curtain then uses as little
energy as possible without compromising too
much on comfort. Energy savings of up to 35
percent are possible.
Open/closed door
Outdoor temperature
Room temperature
12
Air curtains - Control system SIRe
Advanced
Competent
n
rr
et
tem urn
pe wate
Ad
rat
va
ur r
e
nc
ed
BM
SRe
sy
ad
ste
yf
m
or
ga
te w
ay
BM
S
Ma
xl
im
it f
o
er
ti v
ac
Pro
Co
mf
eg
ort
ula
mo
tio
de
e
od
om
sy
SBM
Ec
ste
m
rm
ala
ple
da
len
Fil
te r
un
rf
en
Ca
Sim
cti
on
de
mo
e
Op
od
le
m
xib
Fle
mo
ma
Au
to
Ma
nu
al
op
tic
era
tio
n
de
Basic
SIRe is an intelligent and well designed low voltage
control system which can be customised for each unique
application and environment. SIRe is supplied preprogrammed with quick fit plug connections and is very
easy to use and install.
SIRe learns the requirements in the entrance it
is installed in (e.g. opening frequency and outdoor
temperature). It has calendar function and selectable
switch off at set temperatures for up to nine units. Because
the fan speed is adapted, the sound level is optimized and
is never higher than is necessary for comfort. With SIRe
Advanced it is possible to choose between Eco and Comfort
mode dependent on whether energy savings or optimal
comfort has been prioritised. The return water temperature
can be limited, thus ensuring that the available heat is
exploited to the maximum.
SIRe can control up to nine units. If more than one air
curtain should be controlled by a single SIRe, an additional
modular cable SIReCC RJ12 (6p/6c) per unit is needed.
Cables between units can easily be joined together by using
joint piece SIReCJ6.
There are three different levels with different functionality
to choose from, Basic, Competent or Advanced.
Included in SIReB Basic:
• SIReUB1, control unit. Wall unit cover included.
• SIReCC, modular cable, RJ12(6p/6c), 5 m
Options:
• SIReRTX, external room temperature sensor, RJ11
(4p/4c), 10 m
• VOS(P), (pressure independent) valve kit on/off or VOT,
three way valve and actuator on/off
Included in SIReAC Competent:
• SIReUA1, control unit. Wall unit cover included.
• SIReC1X, PC board HUB Competent
• SIReDC, door contact
• SIReCC, modular cables, RJ12(6p/6c), 3 m resp. 5 m
Options:
• SIReRTX, external room temperature sensor, RJ11
(4p/4c), 10 m
• SIReUR, kit for recessed installation
• VOS(P), (pressure independent) valve kit on/off or VOT,
three way valve and actuator on/off
Included in SIReAA Advanced:
Control system SIRe
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
• SIReUA1, control unit. Wall unit cover included.
• SIReA1X, PC board HUB Advanced
• SIReOTX, outdoor temperature sensor
• SIReDC, door contact
• SIReCC, modular cables, RJ12(6p/6c), 3 m resp. 5 m
Options:
• SIReRTX, external room temperature sensor, RJ11
(4p/4c), 10 m
• SIReUR, kit for recessed installation
• SIReWTA, clamp-on sensor, RJ11 (4p/4c), 3 m
• VMO(P), (pressure independent) modulating valve kit or
VMT, three way valve and modulating actuator
The SIRe control system must be supplemented with a
VOS(P), VOT, VMO(P) or VMT valve kit for water heated
air curtains, see page 65.
13
Air curtains - Control system SIRe
Air conditioner
control
Building
Management
System
Elevator control
Fire alarm system
Entrance control
SIReRTX
SIReUR
SIReWTA
SIReCJ4
SIReCC
Air curtain control
Integration of Frico air curtains in an overall control
system (BMS)
BMS-control - level 1
With SIRe Competent the air curtains can be integrated
in an overall control system (BMS). The air curtain can be
started/stopped and the fan speed regulated via the BMS
system. A 5-30V control signal is required for starting/
stopping. A 0-10V control signal is required to control the
fan speed. Potential free contact for buzzer.
BMS-control - level 2
With SIRe Advanced the air curtains can be integrated
in an overall control system (BMS). The air curtain can
be started/stopped, the fan speed and heating regulated
smoothly via the BMS system. A 5-30V control signal
is required for starting/stopping. A 0-10V control signal
is required to control the fan speed and heating. Input
for alarm and night reduction via external potential free
contact. Potential free contact for buzzer and operation
indication.
BMS-control - level 3
SIReCJ6
Control system SIRe - options
SIReRTX, external room temperature sensor
Used to obtain a better measuring point in the premises
when the control unit is located so that the internal room
temperature sensor does not show a relevant value. 10 m.
cable with modular connector RJ11 (4p/4c).
SIReUR, kit for recessed installation
Kit for installing SIReUA1 recessed in a wall. Only
protrudes 11 mm from the wall.
SIReWTA, clamp-on sensor
Clamp-on sensor for return water temperature control. 3
m. cable with modular connector RJ11 (4p/4c). Should be
mounted on the return pipe on the heating coil.
SIReCJ4/SIReCJ6, joint piece
Used to join two RJ11 (4p/4c) respectively RJ12 (6p/6c).
SIReCC, modular cables
Modular cables RJ11 (4p/4c) respectively RJ12 (6p/6c).
Available in lengths 3, 5, 10 and 15 m.
With SIRe Advanced it is also possible to communicate via
Modbus RTU (RS485). Contact Frico for more information.
Accessories - SIRe
14
Type
Description
SIReRTX
External room temperature sensor
SIReUR
Kit for recessed installation
SIReWTA
Clamp-on sensor
SIReCJ4
Used to join two RJ11 (4/4)
SIReCJ6
Used to join two RJ12 (6/6)
SIReCC603
Modular cable RJ12 (6/6) 3 m
SIReCC605
Modular cable RJ12 (6/6) 5 m
SIReCC610
Modular cable RJ12 (6/6) 10 m
SIReCC615
Modular cable RJ12 (6/6) 15 m
SIReCC403
Modular cable RJ11 (4/4) 3 m
SIReCC405
Modular cable RJ11 (4/4) 5 m
SIReCC410
Modular cable RJ11 (4/4) 10 m
SIReCC415
Modular cable RJ11 (4/4) 15 m
A i r cur t ai ns
Door heater and Air curtains - Small openings
PA1508
PA1006 is a compact door heater that heats the air around the
door opening. This increases the comfort in the vicinity and
gives personnel close to the opening a better working climate.
With its compact construction and timeless design the unit
is easy to place in any doorway. The intuitive controls are
easily accessible, placed on the gable end.
PA1508, is primarily intended for small
openings, such as kiosk and service hatches
and cashier benches where a long, narrow air
flow is required. This creates a temperature
separating air barrier that prevents cold air
from pushing in and hot air from flowing out.
PA1508 also gives additional heat and in this
0,8 m
way also improves the working environment.
With its compact construction and
timeless design the unit is easy to place in any doorway. The
intuitive controls are easily accessible, placed on the gable end.
The front can be finished in any colour to perfectly match the
environment.
•Integrated selector for the fan and heating.
•The unit is easily angled on the bracket, which is used for
both wall and ceiling mounting.
•Height: 153 mm
•Depth: 164 mm
•Colour front: white, RAL 9016, NCS S 0500-N. Colour grille,
rear section, ends and brackets: grey, RAL 7046.
•CE compliant.
•Approved for 220V/1ph/60Hz. Product performance for
220V/1ph/60Hz will differ from stated data.
Door heater PA1006, electrically heated (IP20)  3
Type
Voltage
PA1006E03
[V]
230V~
Output
steps
[kW]
1.5/3
Airflow
[m³/h]
230
Sound
level
[dB(A)]
44
1,5 m
Door heater PA1006
•Built-in control.
•Units with 2-3 kW are supplied with a 2 m cable and plug.
•Wall brackets included.
•Height: 153 mm
•Depth: 164 mm
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
Length
[mm]
650
PA1508, electrically heated (IP20)  3
Type
Voltage
PA1508E02
PA1508E03
PA1508E05
[V]
230V~
230V~
230V~
Heat
output
[kW]
1/2
2/3
3/5
Airflow
[m³/h]
400
400
400
Sound
level
[dB(A)]
36/48
36/48
36/48
Length
[mm]
790
790
790
Conditions for sound level measurements, see page 67.
15
Air curtains - Entrance
R
PA2200C
Controls
1 Unit without heating
2,2 m
The PA2200C is a compact air curtain,
suitable for most small entrances. The air
curtain has an integrated control system and
can also be remotely controlled which makes
it very easy to use.
PA2200C creates a temperature dividing
air barrier that effectively prevents cold
draughts and gives excellent heating comfort
inside the door.
1 / 1,5 / 2 m
With its timeless design PA2200C is
suitable for all entrances. The air curtain has
a control panel discretely integrated in the end, which makes
cable routing unnecessary.
•Recommended installation height 2,2 m
•Remote control and integrated regulation.
•3 fan steps and 2 electrical heating steps.
•Units with 3 kW are equipped with 1,5 m cable and plug.
•Wall brackets included.
•Height: 210 mm
•Depth: 355 mm
•Colour front: white, RAL 9016, NCS S 0500-N. Colour grille,
rear section, ends and brackets: grey, RAL 7046.
•CE compliant.
Voltage
PA2210CA
PA2215CA
PA2220CA
[V]
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
Airflow
[m³/h]
1200
1800
2400
3 Unit with electrical heating
2 Unit with water heating
•Remote control.
•Integrated control panel on end of
unit
- 3 fan steps, 2 electrical heating
steps (electrical), heating on /off
(water).
•Manual regulation of the fan.
•Automatic heating control.
Accessories
PA2200C A, ambient, unheated (IP21)  1
Type
•Remote control.
•Integrated control panel on end of
unit
- 3 fan steps.
•Manual regulation of the fan.
Sound
level
[dB(A)]
42/51
40/52
43/53
Length
[mm]
1050
1560
2050
PA2DR
PA2200C E, electrically heated (IP20)  3
Type
Voltage
PA2210CE03
PA2210CE05
PA2210CE08
PA2215CE08
PA2215CE12
PA2215CE10
PA2220CE16
[V]
230V~
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
Heat
output
[kW]
2/3
2,5/5
5/8
4/8
8/12
5/10
8/16
Airflow
[m³/h]
1200
1200
1200
1800
1800
2400
2400
Sound
level
[dB(A)]
42/51
42/51
42/51
40/52
40/52
43/53
43/53
Length
[mm]
1050
1050
1050
1560
1560
2050
2050
PA2DR, door switch control
Contains a door switch for door indication and a special
remote control intended to activate auto mode in the unit.
Valve kit VOT is used to control the water flow. For more
information see the "Controls" section.
PA2200C W, water heated (IP21)  2
Type
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
PA2210CW
230V~
6,9
1200
39/52
1050
PA2215CW
230V~
11,1
1750
37/53
1560
PA2220CW
230V~
14,4
2400
43/53
2050
*) Applicable at water temperature 80/60 ºC, air temperature, in +18 ºC.
16
Type
Description
PA2DR
Door switch control
VOT15
3-way valve and actuator on/off DN15, Kvs 1,7
VOT20
3-way valve and actuator on/off DN20, Kvs 2,5
VOT25
3-way valve and actuator on/off DN25, Kvs 4,5
More information about accessories on pages 17 and 65.
A i r cur t ai ns
Air curtains - Entrance
R
PA2500
Accessories PA2200C and PA2500
2,5 m
The PA2500 creates a temperature dividing
air barrier that effectively prevents cold
drafts and gives excellent heating comfort in
door ways, such as shops, offices and public
offices.
The air curtain has many intelligent and
energy saving features which provide fully
automatic protection for the entrance,
adaptable to each area of use.
The PA2500 has a modern and stylish
design developed to fit all entrances.
1 / 1,5 / 2 m
PA2PF
•Recommended installation height 2,5 m
•3 fan steps and 3 electrical heating steps, which give more
even comfort and extra energy savings.
•Wall brackets included.
•Height: 210 mm
•Depth: 355 mm
•Colour front: white, RAL 9016, NCS S 0500-N. Colour grille,
rear section, ends and brackets: grey, RAL 7046.
•CE compliant.
PA34TR
PA2P
PA2PF, ceiling mounting brackets
Mountings for installing the unit in the ceiling using hanging
brackets or threaded bars (not included).
PA34TR, threaded bars
Threaded bars for installing unit on to a ceiling. Length 1 m.
Used together with ceiling mounting brackets PA2PF.
PA2P, hanging brackets
PA2500E, electrically heated (IP20)  3
Type
Voltage
PA2510E05
PA2510E08
PA2515E08
PA2515E12
PA2520E10
PA2520E16
[V]
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
Heat
output
[kW]
1,7/3,3/5
3/5/8
3/5/8
4/8/12
3,4/6,7/10
6/10/16
Airflow
[m³/h]
1450
1450
2200
2200
2900
2900
Sound
level
[dB(A)]
42/51
42/51
40/52
40/52
43/53
43/53
Length
[mm]
1050
1050
1560
1560
2050
2050
PA2500W, water heated (IP21)  2
Type
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
PA2510W
230V~
4,7
1300
42/53
1050
PA2515W
230V~
9,2
2100
41/54
1560
PA2520W
230V~
11,5
2600
43/55
2050
*
) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
Hanging brackets for installing the unit suspended from the
ceiling. Length 1 m. The hanging brackets are covered by a
white plastic trim to cover the cables. The brackets may be
cut to shorter length, if required. Used together with ceiling
mounting brackets PA2PF.
Accessories - PA2200C and PA2500
Type
Description
PA2PF15
PA2PF20
PA34TR15
PA34TR20
PA2P15
PA2P20
Ceiling mounting brackets for 1 and 1,5 metre units, 4 pcs
Ceiling mounting brackets for 2 metre units, 6 pcs
Threaded bars for 1 and 1,5 metre units, 4 pcs
Threaded bars for 2 metre units , 6 pcs
Hanging brackets for 1 and 1,5 metre units, 2 pcs
Hanging brackets for 2 metre units, 3 pcs
Controls
This air curtain is supplied with an intregrated PC board SIRe.
There are three different levels with different functionality to
choose from, Basic, Competent or Advanced. Read more about
SIRe on page 12-14. Valve kit VOS(P), VOT, VMO(P) or VMT
is used to control the water flow. For more information see the
"Controls" section.
SIReB Basic
SIRe Competent
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
SIRe Advanced
17
Air curtains - Entrance
R
AD200
Controls
Unit without heating
Level 1
2,5 m
Excellent for use in customer entrances
where doors are frequently opened;
shops, restaurants, supermarkets etc.
An adjustable air outlet grille makes it
possible to direct the air for an optimal air
curtain effect. Adjustable distance between
mounting brackets.
-CB30N, control box, 3 fan steps.
•Recommended installation height 2,5 m
•Wall brackets included.
1 / 1,5 / 2 m
•Height: 225 mm
•Depth: 350 mm
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
Voltage
AD210A
AD215A
AD220A
[V]
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
Airflow
[m³/h]
1400
2100
2800
-CB32N, control box, 3 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
Level 2
-CB32N, control box, 3 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
-MDC, magnetic door contact with a time relay.
Unit with water heating
Note! A valve set VR20/25 (option: TVV20/25 with SD20)
should be added for a complete control kit.
AD200A, ambient, unheated (IP21)  1
Type
Unit with electrical heating
Level 1
Sound
level
[dB(A)]
41/51
43/53
44/54
Length
Level 1
[mm]
1020
1530
1960
Level 2
-CB30N, control box, 3 fan steps.
-T10, room thermostat IP30.
-CB30N, control box, 3 fan steps.
-RTI2, electronic 2-step thermostat
-MDC, magnetic door contact with a time relay.
AD200C, electrically heated, built-in thermostat and control
box, cable and plug (IP21)  3
Type
Voltage
AD210C03
AD210C05
[V]
230V~
230V~
Heat
output
[kW]
2/3
2,3/4,5
Airflow
[m³/h]
1400
1400
Sound
level
[dB(A)]
41/47
41/47
Length
[mm]
1020
1020
AD200E, electrically heated (IP21)  3
Type
Voltage
AD210E03
AD210E06
AD210E09
AD215E05
AD215E09
AD215E14
AD220E12
AD220E18
[V]
230V~
400V3N~
400V3N~
400V3N~
400V3N~
400V3N~
400V3N~
400V3N~
Heat
output
[kW]
1,5/3
3/6
4,5/9
2,3/4,5
4,5/9
6,7/13,5
6/12
9/18
Airflow
[m³/h]
1400
1400
1400
2100
2100
2100
2800
2800
Sound
level
[dB(A)]
41/51
41/51
41/51
43/53
43/53
43/53
44/54
44/54
Length
[mm]
1020
1020
1020
1530
1530
1530
1960
1960
AD200W, water heated (IP21)  2
Type
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AD210W
230V~
7
1200
38/49
1020
AD215W
230V~
12
1800
40/51
1530
AD220W
230V~
15
2400
41/52
1960
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
18
Accessories - AD200
Type
Description
CK01E
Control kit Electric level 1 (CB32N, RTI2)
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK03
Control kit level 3 (ADEA, ADEAIS, ADEAEB)
CK01W
Control kit Water level 1 (CB30N, T10)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N
Control box (A/W)
CB32N
Control box (E)
KRT2800
2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
22003
False ceiling grille 1192 mm
22004
False ceiling grille 1515 mm
ADPK1
Suspension kit, max 1 m
ADPF1
Suspension brackets (4 pcs)
More information about accessories on pages 29, 34 and 63-64.
A i r cur t ai ns
Air curtains - Entrance
R
Portier
Accessories
2,5 m
Portier is an exclusive air curtain in
brushed stainless steel intended for
entrance doors in e.g. shops, banks, hotels
and restaurants. The elegant design of the
air curtain makes it particularly suitable
for environments where demands are
made on a high standard of design.
Portier has a unique symmetrical
design in brushed stainless steel with
black grille and ends.
2x
1 / 1,5 m
•Recommended installation height 2,5 m
•Height: 280 mm
•Depth: 290 mm
•Housing in brushed stainless steel. Colour outlet grille and
ends: black, RAL 9005.
•CE compliant.
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
Portier 200A, ambient, unheated (IP21) 1
Type
Voltage
PS210A
PS215A
[V]
230V~
230V~
Heat
output
[kW]
0
0
Airflow
[m³/h]
1300
2000
Sound
level
[dB(A)]
44/54
46/56
Length
[mm]
1020
1530
Portier 200E, electrically heated (IP21)  3
Type
Voltage
Heat
Airflow Sound
Length
output
level
[V]
[kW]
[m³/h] [dB(A)]
[mm]
PS210E03 230V~/400V3N~* 1,5/3
1200
44/50
1020
PS210E06 400V3N~*
3/6
1200
44/50
1020
PS210E09 400V3N~*
4,5/9
1200
44/50
1020
PS215E09 400V3N~*
4,5/9
1900
39/50
1530
PS215E14 400V3 + 230V~
6,7/13,5
1900
39/50
1530
*) Alternative 400 V3~ + 230 V~ (operating supply) if the current is
greater than 16 A. Applies when connecting several units.
Controls
Unit without heating
Level 1
-CB20, control box, 2 fan steps.
Level 2
P2WB
P2JK
ADPK1
ADPF1
P2WB, wall mounting kit
Used for installing unit horizontally on a wall. Consists of wall
brackets and mounting parts.
P2JK, joining kit
Used to join horizontal units together for a sleek and unified
installation. Consists of joint bracket and mounting parts.
ADPK1, suspension kit
The hanging brackets are covered by a white plastic trim to
cover the cables. The brackets may be cut to shorter length, if
required.
ADPF1, suspension brackets
Ceiling brackets for installing the unit from the ceiling using
wires or threaded bars (not included). Consists of 4 brackets, 2
for the unit and 2 for the ceiling.
Accessories - Portier
Type
Description
CB20
Control box (A)
CB22
Control box (E)
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
MDC
Magnetic door contact with time relay, IP44
ADPK1
Suspension kit, max 1 m
ADPF1
Suspension brackets (4 pcs)
P2WB
Wall mounting kit
P2JK
Joining kit 2x1 m
More information about accessories on pages 34 and 63-64.
-CB20, control box, 2 fan steps.
-MDC, magnetic door contact with a time relay.
Unit with electrical heating
Level 1
-CB22, control box, 2 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
Level 2
-CB22, control box, 2 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
-MDC, magnetic door contact with a time relay.
Conditions for sound level measurements, see page 67.
19
Air curtains - Entrance and Cold storage
R
R
ADA Cool
ADA is suitable to use, for example, to keep
the cold air inside air conditioned premises.
The air curtain creates an air barrier that
prevents the intrusion of warm air and also
insects, exhaust fumes, smoke, dust, etc. The
cost of air conditioning will be substantially
lower when the loss of conditioned air is
reduced.
Thanks to compact design and air intake
at the front, the air curtain can be mounted
where space is limited between the ceiling
and the upper edge of the doorway.
ADA Cool keeps the cold air in cold stores
and also makes it possible to have an open
cold store area without doors.The air
curtain creates an air barrier that prevents
the intrusion of warm air and also insects,
exhaust fumes, smoke, dust, etc. The cost
of cooling is significantly reduced and the
cold air stays where it is needed. ADA Cool
reduces ice formation and condensation by
the doorway and improves visibility when
0,9 / 1,2 m
compared to plastic strips and fast folding
doors.
Thanks to compact design and air intake at the front, the
air curtain can be mounted where space is limited between
the ceiling and the upper edge of the doorway. ADA Cool has
a simple connection making it possible to easily link units
together in order to cover wide openings.
2,5 m
2,5 m
ADA
0,9 / 1,2 m
•Built‑in switch; high/low speed.
•Compact and easily positioned.
•Recommended installation height 2,5 m
•Wall brackets included.
•Height: 235 mm
•Depth: 215 mm
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
•Approved for 220V/1ph/60Hz. Product performance for
220V/1ph/60Hz will differ from stated data.
ADA, ambient, unheated (IP21)  1
Type
Voltage
ADA090H
ADA120H
ADA090L
ADA120L
[V]
230V~
230V~
230 V~
230 V~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
1150
1400
820
1350
Sound
level
[dB(A)]
43/54
44/51
43/54
48/55
Length
[mm]
900
1200
900
1200
•Recommended installation height 2,5 m
•Wall brackets included.
•Height: 235 mm
•Depth: 215 mm
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
•Approved for 220V/1ph/60Hz. Product performance for
220V/1ph/60Hz will differ from stated data.
ADA Cool, ambient, unheated (IP21)  1
Type
Voltage
ADAC090
ADAC120
[V]
230V~
230V~
Heat
output
[kW]
0
0
Airflow
[m³/h]
1150
1400
Sound
level
[dB(A)]
54
51
Length
[mm]
900
1200
Controls
ADACR, 5-step fan speed control
ADACR is a control and connection
set consisting of a 5-step fan speed
control, flexible cable and earthed plug.
Can control a maximum of 7-9 units
(max. 7 units at 60 Hz). Max input: 5 A.
Dimensions: 200x105x105 mm. IP30.
2,2 m
ADA CR
5 A
2,2 m
Conditions for sound level measurements, see page 67.
20
Type
Description
ADACR
5-step fan speed control
A i r cur t ai ns
Air curtains - Entrance
AR200
Controls
Unit without heating
Level 1
2,5 m
AR200 is a compact air curtain, suitable
for most small entrances. A low height
makes it possible to install AR200 where
ceiling space is limited. The recessed
installation and low sound level makes
AR200 very discreet.
AR200 is designed for recessed
installation and the visible bottom plate
may be painted to make it blend in even
better with the surroundings.
-CB30N, control box, 3 fan steps.
Unit with electrical heating
Level 1
1 / 1,5 / 2 m
•Just one model per length, but
electrical units are convertible between several outputs and
230V~/400V3N~ making it simple and flexible to adapt the
output to current need.
•Recommended installation height 2,5 m
•Height: 198 mm
•Depth: 432 mm
•CE compliant.
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
Voltage
Output
Airflow
AR210A
AR215A
AR220A
[V]
230V~
230V~
230V~
[kW]
0
0
0
[m³/h]
1200
1750
2400
Level 2
-CB32N, control box, 3 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
-MDC, magnetic door contact with a time relay.
Unit with water heating
Note! A valve set VR20/25 (option: TVV20/25 with SD20)
should be added for a complete control kit.
Level 1
-CB30N, control box, 3 fan steps.
-T10, room thermostat IP30.
Level 2
AR200A, ambient, unheated (IP20)  1
Type
-CB32N, control box, 3 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
Sound
level
[db(A)]
34/50
34/50
40/54
Length
[mm]
1042
1552
2042
-CB30N, control box, 3 fan steps.
-RTI2, electronic 2-step thermostat
-MDC, magnetic door contact with a time relay.
Accessories - AR200
AR200E, electrically heated (IP20)  3
Type
Output
Output
Airflow
Sound
Length
steps
steps
level
400V3N~ 230V~
[kW]
[kW]
[m³/h]
[db(A)]
[mm]
0/3
0/6/9
AR210E09
1200
34/50
1042
0/3
0/3/5
0/4,5
0/6,8/11,3 AR215E11
1750
34/50
1552
0/4,5
0/4,5/6,8
0/6
0/12/18
AR220E18
2400
40/54
2042
0/6
0/6/10
AR200E is delivered as 9 kW, 11 kW and 18 kW (400 V3N~) models, but
they are convertible to 230 V~ and different outputs as shown in above
table.
Type
Description
CK01E
Control kit Electric level 1 (CB32N, RTI2)
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK01W
Control kit Water level 1 (CB30N, T10)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB32N
Control box (E)
CB30N
Control box (A/W)
T10
Electronic thermostat, IP44
KRT2800 2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
MDC
Magnetic door contact with time relay, IP44
MDCDC
Magnetic door contact
CBT
Electronic timer, IP44
KUR
Digital time switch, IP55
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
More information about accessories on pages 34 and 63-66.
AR200W, water heated (IP20)  2
Type
Voltage
Output*
Airflow
Sound
Length
level
[V]
[kW]
[m³/h]
[db(A)]
[mm]
AR210W
230V~
6,6
1000
41/49
1042
230V~
10,4
AR215W
1600
37/50
1552
AR220W
230V~
13,0
2000
44/53
2042
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
21
Air curtains - Commercial
R
AR300
Control
3,5 m
AR300 is very discreet thanks to its
concealed appearance in the ceiling and
built-in control that requires no wiring.
The IR-eye in the Plug & play control
detects if the door is opened or closed and
controls the air curtain accordingly.
AR300 is intended for recessed
installation and the frame and hatch can be
painted in colours that blend well with the
premises.
1 / 1,5 / 2 m
•Recommended installation height 3,5 m
•Height: 302 mm
•Depth: 595 mm
•Colour frame and hatch: white, RAL 9016, NCS S 0500-N.
Colour grille: grey, RAL 7046.
•Approved by SEMKO and CE compliant.
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
Accessories
AR300E, electrically heated (IP44)*  3
Type
Voltage
AR310E09
AR315E14
AR320E18
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
4,5/9
7/13,5
9/18
The built-in control of AR300 is designed to give the highest
level of functionality while minimizing installation and daily
operation. No additional wiring or external controls are
needed.
The air curtain operates at its maximum performance in all
situations and is not dependent on day-to-day adjustments.
When the door is open the air curtain separates outdoor and
indoor air and provides heat if it is needed.
When the door is closed the air curtain operates as part
of the heating system supplying additional heat if indoor
temperature falls below desired temperature. There are also
possibilities to connect the air curtain to a BMS system for on/
off control and alarm indication.
Note! A valve set VR20/25 (option: TVV20/25 with SD20)
should be added for a complete control kit.
Airflow
[m³/h]
2000
2800
4000
Sound
level
[dB(A)]
43/59
43/60
46/63
Length
[mm]
1057
1567
2073
AR300DS
AR300W, water heated (IP44)*  2
Type
Voltage
Airflow
Heat
Sound
Length
output*1
level
[kW]
[V]
[m³/h]
[dB(A)]
[mm]
AR310W
230V~
8,6
2000
43/58
1057
AR315W
230V~
12,6
2800
43/59
1567
AR320W
230V~
18,3
4000
46/62
2073
*1) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
*) Protection class, recessed mounting above suspended
ceilings: IP44, hanging on rods without suspended ceiling:
IP20.
The thermostat setting
and open door fan speed
selection is hidden under
the cover.
The IR-eye detects when the
door is open and closed. The
thermostat is located by the
air intake and heat or ambient
mode is set by a push button.
Alarm indication by LED.
22
AR300ERS
AR300DS, external door contact
When the distance between the eye and the reflector is
too long an external door contact AR300DS is needed.
The external door contact is supplied with 7 m cable and a
modular connector for easy and quick installation (no other
adjustments are needed to get the accessories working). The
connection of the door contact is done on the control box
accessible by opening the service hatch of the AR300.
AR300ERS, external room sensor
If an external room sensor is needed, use the AR300ERS.
The external room sensor is supplied with 7 m cable and a
modular connector for easy and quick installation (no other
adjustments are needed to get the accessories working). The
connection of the room sensor is done on the control box
accessible by opening the service hatch of the AR300.
Type
Description
AR300DS
External door contact, with 7 m cable
AR300ERS External room sensor, with 7 m cable
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
More information about accessories on page 66.
A i r cur t ai ns
Air curtains - Commercial
R
AR3500
Controls
3,5 m
With its concealed location, AR3500 is
very unobtrusive and with that particularly
suitable for environments where the design
is important.
The air curtain has many intelligent and
energy saving features which provide fully
automatic protection for the entrance,
adaptable to each area of use.
AR3500 is intended for recessed
installation and the frame and hatch can be
painted in colours that blend well with the
premises.
SIReB Basic
SIRe Competent
SIRe Advanced
1 / 1,5 / 2 m
•Recommended installation height 3,5 m
•Height: 302 mm
•Depth: 595 mm
•Colour frame and hatch: white, RAL 9016, NCS S 0500-N.
Colour grille: grey, RAL 7046.
•Approved by SEMKO and CE compliant.
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
This air curtain is supplied with an intregrated PC board SIRe.
There are three different levels with different functionality to
choose from, Basic, Competent or Advanced. Read more about
SIRe on page 12-14. Valve kit VOS(P), VOT, VMO(P) or VMT
is used to control the water flow. For more information see the
"Controls" section.
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
AR3500A, ambient, unheated (IP44)*  1
Type
Voltage
AR3510A
AR3515A
AR3520A
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
0
0
0
Airflow
[m³/h]
2100
2900
4200
Sound
level
[dB(A)]
39/58
40/58
41/61
Length
[mm]
1057
1567
2073
Accessories
AR3500E, electrically heated (IP44)*  3
Type
Voltage
AR3510E09
AR3515E14
AR3520E18
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
4,5/9
7/13,5
9/18
Airflow
[m³/h]
2100
2900
4200
Sound
level
[dB(A)]
39/58
40/58
41/61
Length
[mm]
1057
1567
2073
AR3500W, water heated (IP44)*  2
Type
Voltage
Airflow
Heat
Sound
Length
output*1
level
[kW]
[V]
[m³/h]
[dB(A)]
[mm]
AR3510W
230V~
8,6
2100
39/58
1057
AR3515W
230V~
12,6
2900
40/58
1567
AR3520W
230V~
18,3
4200
41/61
2073
*1) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
AR35XTT, extension
Outlet/inlet extension for a discreet installation with only the
outlet and inlet visible in the ceiling.
Type
Description
AR35XTT10
AR35XTT15
AR35XTT20
Extension for AR3510
Extension for AR3515
Extension for AR3520
*) Protection class, recessed mounting above suspended
ceilings: IP44, hanging on rods without suspended ceiling:
IP20.
23
Air curtains - Commercial
R
Corinte
ADCS: 1,7 / 2,2 m
ACCS: 1 / 1,5 / 2 / 2,5 / 3 m
ADCS: 2,2 / 2,5 m
ACCS: 2 / 2,5 / 3 m
•Recommended installation height 3 m
•Recommended installation width 5 m (2 units, one on each
side)
•Available in polished, mirror-polished or brushed stainless
steel. Colour intake and outlet grille: black, RAL 9005.
•CE compliant.
3m
Corinte is intended for exclusive shop entrances and other
environments with high demands in respect of design and
soundlevel. Mounted with one unit on either side of the
opening, thus creating a classic symmetry, the curtain effect
and comfort is optimized.
The air curtain has many intelligent and energy saving
features which provide fully automatic protection for the
entrance, adaptable to each area of use.
Corinte is a stylish and exclusive, stainless steel air curtain
for horizontal or vertical installation. Corinte is available in
two models; ADCS and ACCS that have varying dimensions
and performance. The product key offers many options for the
design and finish of both models.
5m
Controls
Product key
Type - Unit shape - Connections position - Finish / Material
Example: ADCS22WL - VL - A - P
SIReB Basic
SIRe Competent
SIRe Advanced
This air curtain is supplied with an intregrated PC board SIRe.
There are three different levels with different functionality to
choose from, Basic, Competent or Advanced. Read more about
SIRe on page 12-14. Valve kit VOS(P), VOT, VMO(P) or VMT
is used to control the water flow. For more information see the
"Controls" section.
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
Type
See technical specifications
Unit shape
HL (Horizontal, connections to the left),
HR (Horizontal, connections to the right),
VL (Vertical Left) or VR (Vertical Right)
Connections
position
A or B, see figure.
Finish / material
P = Polished bright annealed
B = Brushed stainless steel
MP = Mirror polished stainless steel
Connections position
Horizontal
HL
24
Vertical
HR
A
A
B
B
Corinte ADCS
•Wall brackets included.
•Height: 500 mm
•Depth: 350 mm
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
Corinte ADCS A, ambient, unheated (IP20)  1
Type
Voltage
ADCS17A*¹
ADCS22A
ADCS25A*²
[V]
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
Airflow
[m³/h]
3000
4000
4500
Sound
level
[dB(A)]
40/60
42/61
43/63
Length
[mm]
1700
2200
2450
Type
Voltage
ADCS17E*¹
ADCS22E
ADCS25E*²
[V]
230V~/400V3~
230V~/400V3~
230V~/400V3~
Heat
output
[kW]
0/7,5/15
0/10/20
0/11,2/22,5
Airflow
[m³/h]
3000
4000
4500
Sound
level
[dB(A)]
40/60
42/61
43/63
Length
[mm]
1700
2200
2450
Corinte ADCS WL, water heated (IP20)  2
Type
Corinte ACCS
•Height: 395 mm
•Depth: 315 mm
Corinte ACCS E, electrically heated (IP20)  3
Type
Voltage
ACCS10E08*¹
ACCS15E12*¹
ACCS20E16
ACCS25E20
ACCS30E23
[V]
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
230V~/400V3~
Voltage
Airflow
Heat
Sound
Length
output*3
level
[kW]
[V]
[m³/h]
[dB(A)]
[mm]
ADCS17WL*¹ 230V~
17,3
3000
39/59
1700
ADCS22WL
230V~
24,5
4000
42/60
2200
ADCS25WL*² 230V~
28,0
4500
42/61
2450
*¹) ADCS17 is available only for horizontal mounting.
*²) ADCS25 is available only for vertical mounting.
*3) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
Heat
output
[kW]
2,7/5,4/8,1
3,9/7,8/11,7
5,4/10,8/16,2
6,6/13,2/19,8
7,8/15,6/23,4
Airflow Sound
level
[m³/h] [dB(A)]
1900
44/61
2600
45/62
3800
47/64
4500
48/65
5100
48/65
Length
[mm]
1000
1500
2000
2500
3000
Corinte ACCS WL, water heated (IP20)  2
Type
Corinte ADCS E, electrically heated (IP20)  3
A i r cur t ai ns
Air curtains - Commercial
Voltage
Airflow
Heat
Sound
Length
output*2
level
[kW]
[V]
[m³/h]
[dB(A)]
[mm]
ACCS10WL*¹
230V~
9,0
1900
44/61
1000
ACCS15WL*¹
230V~
16,8
2600
45/62
1500
ACCS20WL
230V~
23,5
3800
47/64
2000
ACCS25WL
230V~
29,3
4500
48/65
2500
ACCS30WL
230V~
34,6
5100
48/65
3000
*¹) Only available for horizontal mounting.
*2) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC
and horizontal mounting.
Accessories ACCS
FH1025
Accessories ADCS
ACCW
ACCSEH
AXP300
ACCW, wall bracket
ADCSEH
ADCM P/S
AXP300
Brackets for installing unit horizontally on a wall. Two are
required for 1 and 1.5 metre units, while 2 and 2.5 metre units
need three and 3 metre units need four.
Available in three designs:
- ACCWBB, brushed stainless steel
- ACCWBP, polished stainless steel
- ACCWBMP, mirror polished stainless steel
ADCSEH, extension hood
Fills the space between the unit and the ceiling for vertical
mounting and provides a neater installation. Special order to
required dimension. Height 100-1000 mm.
ACCSEH, extension hood
Fills the space between the unit and the ceiling for vertical
mounting and provides a neater installation. Special order to
required dimension. Height 100-1000 mm.
ADCM P/S, joining kit
Used to join horizontal units together for a sleek and unified
installation. ADCMP for suspended installation and ADCMS for
wall installation.
AXP300, collision protection
AXP300, collision protection
FH1025, flexible hose
Floor placed protection against impact from e.g. shopping
trolleys.
Floor placed protection against impact from e.g. shopping
trolleys.
Flexible hose (DN25, 1" inside thread) for easy connection to
the pipe system.
Accessories - Corinte ADCS
Accessories - Corinte ACCS
Type
Description
Type
Description
ADCMP
Joining kit for suspended mounting
ACCWBB
Wall bracket, brushed stainless steel
ADCMS
Joining kit for wall mounting
ACCWBP
Wall bracket, polished stainless steel
ADCSEH
Extension hood 100-1000 mm
ACCWBMP
Wall bracket, mirror polished stainless steel
AXP300
Collision protection
ACCSEH
Extension hood 100-1000 mm
AXP300
Collision protection
FH1025
Flexible hoses DN25, inside thread, 1 pcs
25
Air curtains - Commercial
R
PA4200
With air curtains PA3500 and PA4200 there are more
opportunities than ever before, packed into the same product.
There are therefore many areas of use.
The air curtain has many intelligent and energy saving
features which provide fully automatic protection for the
entrance, adaptable to each area of use.
The air curtain is available for horizontal, vertical and
recessed installation.
•The air curtain is complemented with a vertical pack for
vertical installation.
•The accessory Design kit enables a neat installation with
concealed mountings, pipes and cables.
•Colour front and service hatch: white, RAL 9016,
NCS S 0500-N. Colour grille, rear section and ends: grey,
RAL 7046.
•CE compliant.
PA3500: 5 m
PA4200: 6 m
PA3500: 3,5 m
PA4200: 4,2 m
PA3500 and PA4200
1,5 / 2 / 2,5 m
PA3500
1 / 1,5 / 2 / 2,5 m
PA3500
PA3500 is particularly suitable for entrances to stores and
shopping centres for example.
•Recommended installation height 3,5 m
•Recommended installation width 5 m (2 units, one on each
side)
•Height: 270 mm
•Depth: 525 mm
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
PA3500A, ambient, unheated (IP21)  1
Type
Voltage
PA3510A
PA3515A
PA3520A
PA3525A
[V]
230V~
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
1800
2600
3200
4600
Voltage
PA3510E08
PA3515E12
PA3520E16
PA3525E20
[V]
230V/400V3~
230V/400V3~
230V/400V3~
230V/400V3~
Heat
output
[kW]
2,7/5,4/8,0
3,9/7,8/12
5,4/10,8/16
6,6/13,2/20
Voltage
PA4200 is specifically designed for doorways in for example,
large commercial installations or industrial and warehouse
buildings.
•Recommended installation height 4,2 m
•Recommended installation width 6 m (2 units, one on each
side)
•Height: 295 mm
•Depth: 611 mm
Type
Voltage
[mm]
1039
1549
2039
2549
PA4210A
PA4215A
PA4220A
PA4225A
[V]
230V~
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
2700
3700
5300
6350
Sound
level
[dB(A)]
46/64
46/64
47/65
49/67
Length
[mm]
1039
1549
2039
2549
PA4200E, electrically heated (IP20)  3
Airflow
[m³/h]
1800
2600
3200
4600
Sound
level
[dB(A)]
40/57
40,5/58,5
42/59,5
42/60,5
Length
Type
Voltage
[mm]
1039
1549
2039
2549
PA4210E12
PA4215E18
PA4220E24
PA4225E30
[V]
230V/400V3~
230V/400V3~
230V/400V3~
230V/400V3~
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
PA3510WL
230V~
11,7
1800
40/57
1039
PA3515WL 230V~
18,1
2600
41/59
1549
PA3520WL 230V~
22,8
3200
42/60
2039
PA3525WL 230V~
32,6
4600
42/61
2549
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
26
PA4200
Length
PA3500WL, water heated (IP21)  2
Type
PA4200
PA4200A, ambient, unheated (IP21)  1
Sound
level
[dB(A)]
40/57
41/59
42/60
42/61
PA3500E, electrically heated (IP20)  3
Type
PA3500
Heat
output
[kW]
3,9/7,8/12
6,0/12,0/18
7,8/15,6/24
9,9/19,8/30
Airflow
[m³/h]
2700
3700
5300
6350
Sound
level
[dB(A)]
46/63,5
46/64
47/64,5
48,5/67
Length
[mm]
1039
1549
2039
2549
PA4200WL, water heated (IP21) 2
Type
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
PA4210WL
230V~
16,9
2700
46/64
1039
PA4215WL 230V~
24,7
3700
46/64
1549
PA4220WL 230V~
34,8
5300
47/65
2039
PA4225WL 230V~
43,8
6350
49/67
2549
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
A i r cur t ai ns
Air curtains - Commercial
Controls
This air curtain is supplied with an intregrated PC board SIRe.
There are three different levels with different functionality to
choose from, Basic, Competent or Advanced. Read more about
SIRe on page 12-14. Valve kit VOS(P), VOT, VMO(P) or VMT
is used to control the water flow. For more information see the
"Controls" section.
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
SIReB Basic
SIRe Competent
SIRe Advanced
Accessories PA3500/4200 - Horizontal mounting
PA34WB
PA34CB
PA34WS
PA34TR
PA34VD
PA34WB, wall brackets
Joint bracket, included in the
joining kit
PA3XT/PA4XT
Type
Description
PA34WB15
Wall brackets for 1 and 1,5 metre units, 2 pcs
PA34WB20
Wall brackets for 2 metre units, 3 pcs
PA34WB30
Wall brackets for 2,5 metre units, 4 pcs
PA34CB15
Ceiling brackets for 1 and 1,5 metre units, 4 pcs
PA34CB20
Ceiling brackets for 2 metre units, 6 pcs
PA34WS, wire suspension kit
PA34CB30
Ceiling brackets for 2,5 metre units, 8 pcs
Galvanized wires with wire locks to secure the unit from
the ceiling. Length 3 m. Used together with ceiling brackets
(PA34CB).
PA34WS15
Wire suspension kit for 1 and 1,5 metre units, 4 pcs
PA34WS20
Wire suspension kit for 2 metre units, 6 pcs
PA34WS30
Wire suspension kit for 2,5 metre units, 8 pcs
PA34TR15
Threaded bars for 1 and 1,5 metre units, 4 pcs
PA34TR, threaded bars
PA34TR20
Threaded bars for 2 metre units, 6 pcs
Threaded bars for installing unit on to a ceiling. Length 1 m.
Used together with ceiling brackets (PA34CB). Supplemented
with vibration dampers (PA34VD) for reduced vibration.
PA34TR30
Threaded bars for 2,5 metre units, 8 pcs
PA34VD15
Vibration dampers for 1 and 1,5 metre units, 4 pcs
PA34VD20
Vibration dampers for 2 metre units, 6 pcs
PA34VD30
Vibration dampers for 2,5 metre units, 8 pcs
PA3JK
Joining kit PA3500
PA4JK
Joining kit PA4200
PA3XT10
Outlet extension for PA3510, 130-200 mm
PA3JK/PA4JK, joining kit
PA3XT15
Outlet extension for PA3515, 130-200 mm
Used to join horizontal units together for a sleek and unified
installation. Consists of joint bracket and mounting parts.
PA3XT20
Outlet extension for PA3520, 130-200 mm
PA3XT25
Outlet extension for PA3525, 130-200 mm
PA4XT10
Outlet extension for PA4210, 130-200 mm
PA4XT15
Outlet extension for PA4215, 130-200 mm
PA4XT20
Outlet extension for PA4220, 130-200 mm
PA4XT25
Outlet extension for PA4225, 130-200 mm
Brackets for installing unit horizontally on a wall.
PA34CB, ceiling brackets
Ceiling brackets for installing the unit from the ceiling using
wires or threaded bars (not included). Best combined with
vibration dampers (PA34VD) when using threaded bars.
PA34VD, vibration dampers
Reduces vibrations for ceiling installations with threaded bars.
Recessed mounting in suspended ceilings
PA3XT/PA4XT, outlet extension
Outlet extension with telescopic function. Used for recessed
installation of units in suspended ceilings.
27
Air curtains - Commercial
Accessories PA3500/4200 - Vertical mounting
Accessories PA3500/4200 - Unit with water heating
FHDN20
Floor edging, included in the
vertical kit
AXP300
PA34EF
DTV200S
PA3JK/PA4JK, vertical kit
PA34EF, external intake filter
Used to adapt a horizontal unit for vertical installation.
Includes floor frame and mounting parts to support the top.
Vertical kit allows two units to be installed on top of each
other. One vertical kit is needed per unit.
Fine mesh filter that prevents ingress of dirt and deposits to
water heated units. The filter is easy to attach and remove
thanks to the integrated magnetic strips. Makes maintenance
easier since the unit does not need to be opened.
AXP300, collision protection
DTV200, filter pressure guard
Floor placed protection against impact from e.g. shopping
trolleys.
Measures the differential pressure, which indicates how
dirty the filter is in water heated units. The metering hose
is connected to the suction side of the unit (after the filter).
Adjustment is performed on site depending on the unit and
the environment. Adjustable range 20-300 Pa. Potential free,
changeover alarm contact.
Type
Description
PA3JK
PA4JK
AXP300
Vertical kit PA3500
Vertical kit PA4200
Collision protection
FHDN20, flexible hoses
Flexible hoses for easy and practical installation of water
heated unit.
Type
Description
PA34EF10
PA34EF15
PA34EF20
PA34EF25
DTV200S
FHDN20
External intake filter for 1 metre units
External intake filter for 1,5 metre units
External intake filter for 2 metre units
External intake filter for 2,5 metre units
Filter pressure guard
Flexible hoses DN20, inside thread, 90° bend, 1 pair
Accessories PA3500/4200 - Design kit
PA3DW/PA4DW, design kit for wall mounting
Used to conceal mountings, cables and pipes. Used together
with ceiling brackets PA34WB.
PA3VDW/PA4VDW, design kit for vertical
mounting
Used to conceal cables and pipes.
28
PA3DC/PA4DC, design kit for ceiling mounting
Used to conceal mountings, cables and pipes. The design
kit has a telescope function that can be adapted for the
installation. It can also be extended with one or more
extension parts.
Two design kits are required for 1 and 1.5 metre units, while
2 metre units need three kits and 2.5 metre units needed four
kits.
A i r cur t ai ns
Air curtains - Commercial
R
AD300
Controls
Unit without heating
Level 1
3,5 m
Well suited for use in large entrances
such as supermarkets and small industrial
doorways. Combines high performance
with a compact size and an elegant design.
An adjustable air outlet grille makes it
possible to direct the air for an optimal air
curtain effect. Adjustable distance between
mounting brackets.
-CB30N, control box, 3 fan steps.
Level 2
-CB30N, control box, 3 fan steps.
-MDC, magnetic door contact with a time relay.
•Recommended installation height 3,5 m
1 / 1,5 / 2 m
•Wall brackets included.
•Height: 340 mm
•Depth: 490 mm
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
AD300A, ambient, unheated (IP20)  1
Type
Voltage
AD310A
AD315A
AD320A
[V]
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
Airflow
[m³/h]
1900
3200
3800
Sound
level
[dB(A)]
46/57
47/60
50/61
Length
[mm]
1025
1565
2028
Voltage
AD310E09
AD315E14
AD320E18
[V]
400V3~
400V3~
400V3~
Heat
output
[kW]
4,5/9
7/13,5
9/18
Airflow
[m³/h]
1900
3200
3800
Sound
level
[dB(A)]
46/57
47/60
50/61
Length
[mm]
1025
1565
2028
AD300W, water heated (IP20)  2
Type
-CB32N, control box, 3 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
Level 2
-CB32N, control box, 3 fan steps and 2 heating steps.
-RTI2, electronic 2-step thermostat
-MDC, magnetic door contact with a time relay.
Unit with water heating
Note! A valve set VR20/25 (option: TVV20/25 with SD20)
should be added for a complete control kit.
Level 1
-CB30N, control box, 3 fan steps.
-T10, room thermostat IP30.
Level 2
AD300E, electrically heated (IP20)  3
Type
Unit with electrical heating
Level 1
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AD310W
230V~
22
1800
44/57
1025
AD315W
230V~
37
3000
46/59
1565
AD320W
230V~
46
3600
47/60
2028
*) Applicable at water temperature 80/60 ºC, air temperature, in +15 ºC.
Accessories
ADPK1, suspension kit
The hanging brackets are covered by a white plastic trim to
cover the cables. The brackets may be cut to shorter length, if
required.
ADPF1, suspension brackets
Ceiling brackets for installing the unit from the ceiling using
wires or threaded bars (not included). Consists of 4 brackets, 2
for the unit and 2 for the ceiling.
Note! The 2-metres AD-units need 3 fixing points.
22003, 22004, false ceiling grille
Primarily used as air inlet grille when the air curtain is
recessed into a false ceiling.
-CB30N, control box, 3 fan steps.
-RTI2, electronic 2-step thermostat
-MDC, magnetic door contact with a time relay.
Accessories - AD300
Type
Description
CK01E
Control kit Electric level 1 (CB32N, RTI2)
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
CK03
Control kit level 3 (ADEA, ADEAIS, ADEAEB)
CK01W
Control kit Water level 1 (CB30N, T10)
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
CB30N
Control box (A/W)
CB32N
Control box (E)
KRT2800
2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
MDC
Magnetic door contact with time relay, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR20
Valve set, DN 20 mm
VR25
Valve set, DN 25 mm
TVV20
2-way control valve, DN 20 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
22003
False ceiling grille 1192 mm
22004
False ceiling grille 1515 mm
ADPK1
Suspension kit, max 1 m
ADPF1
Suspension brackets
More information about accessories on pages 34 and 63-66.
29
Air curtains - Revolving doors
4m
RDS
SFS
RDS is an ideal air curtain solution
for revolving doors. The air curtain is
installed above the door and the exhaust
duct is adapted to the diameter of the
door, which gives a neat and discrete
3m
solution.
A revolving door prevents continuous
drafts but still lets in a certain amount of
cold air at every rotation. The air curtain
prevents the cold air from penetrating
and gives good heating comfort.
The RDS consists of a unit and an exhaust duct adapted to
the shape and colour of the revolving door.
•Height: 270 mm
•Depth: 525 mm
•The front of the duct is covered by a duct panel that is
available in polished high gloss, polished or brushed stainless
steel. It is also available in powder coated steel, in any RAL/
NCS colour. Exhaust duct and air curtain in powder coated
steel, white, RAL 9016. Aluminium louvres.
•CE compliant.
RDS E, electrically heated (IP20) 3
Type
Voltage
RDS23E08
RDS29E12
RDS38E18
RDS56E23
RDS65E30
[V]
400V3~
400V3~
400V3~
400V3~
400V3~
Heat
output
[kW]
2,7/5,4/8,1
3,9/7,8/11,7
6,0/12,0/18,0
7,8/15,6/23,4
9,9/19,8/29,7
•Standard length 2200 mm. Extension possible up to
3900 mm (extension without fans).
•Height: 295 mm
•Depth: 580 mm
•Available in polished high gloss, polished or brushed stainless
steel. Also available in powder coated steel, any RAL/NCS
colour. Aluminium louvres. Colour intake grille: grey, RAL
7046.
•CE compliant.
SFS E, electrically heated (IP20) 3
Airflow
[m³/h]
2300
2900
3800
5600
6500
Sound
level
[dB(A)]
60
61
62
63
64
Length
Type
Voltage
[mm]
1000
1000
1500
2000
2500
SFS23E08
SFS30E12
SFS38E16
SFS56E23
[V]
400V3~
400V3~
400V3~
400V3~
RDS WL, water heated (IP20) 2
Type
The SFS is an air curtain with many clever
functions, specially designed for revolving
doors. The air curtain is mounted vertically
and its curved design integrates neatly with
the door. SFS efficiently protects the exposed
area just above the floor.
A revolving door prevents continuous drafts
but still lets in a certain amount of cold air
at every rotation. The air curtain prevents
the cold air from penetrating and gives good
heating comfort.
The SFS has a curved design that follows the shape of the
revolving door and is available in powder-coat painted or
stainless steel.
Voltage
Heat
Airflow
Sound Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)] [mm]
RDS23WL
230V~
10,3
2300
60
1000
RDS29WL
230V~
11,7
2900
61
1000
RDS38WL
230V~
17,3
3800
62
1500
RDS56WL
230V~
25,5
5600
63
2000
RDS65WL
230V~
32,0
6500
64
2500
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
Heat
output
[kW]
2,7/5,4/8,1
3,9/7,8/11,7
5,4/10,8/16,2
7,8/15,6/23,4
Airflow
[m³/h]
2300
3000
3800
5600
Sound
level
[dB(A)]
60
61
62
63
Length
[mm]
2200
2200
2200
2200
SFS WL, water heated (IP20) 2
Type
Voltage
Heat
Airflow
Sound Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)] [mm]
SFS23WL
230V~
13,3
2300
60
2200
SFS30WL
230V~
19,9
3000
61
2200
SFS38WL
230V~
23,1
3800
62
2200
SFS56WL
230V~
29,4
5600
63
2200
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
Controls
This air curtain is supplied with an intregrated PC board SIRe.
There are three different levels with different functionality to
choose from, Basic, Competent or Advanced. Read more about
SIRe on page 12-14. Valve kit VOS(P), VOT, VMO(P) or VMT
is used to control the water flow. For more information see the
"Controls" section.
30
SIReB Basic
SIRe Competent
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
SIRe Advanced
A i r cur t ai ns
Air curtains - Industry
AGS5000
AGS6000
R
AGS5000 and AGS6000
AGS5000: 5 m
AGS6000: 6 m
AGS is a powerful air curtain series
intended for industrial doors but it can
also be used for entryways in other large
premises such as shopping malls.
With its many clever, energy saving
functions, the air curtain gives effective
protection, specially adapted for your door.
AGS has a timeless, clean design. The
air curtain is intended for horizontal
installation, models for vertical and
recessed installation are available for
AGS5000: 1,5/2/2,5/3 m
special order.
AGS6000: 1/1,5/2/2,5/3 m
•Colour: white, RAL 9016, NCS S 0500-N. Colour grille: grey,
RAL 7046.
•CE compliant.
•Ambient models are approved for 220V/1ph/60Hz. Product
performance for 220V/1ph/60Hz will differ from stated data.
Controls
SIReB Basic
SIRe Competent
SIRe Advanced
This air curtain is supplied with an intregrated PC board SIRe.
There are three different levels with different functionality to
choose from, Basic, Competent or Advanced. Read more about
SIRe on page 12-14. Valve kit VOS(P), VOT, VMO(P) or VMT
is used to control the water flow. For more information see the
"Controls" section.
Type
Description
SIReB
SIReAC
SIReAA
Control system SIRe Basic
Control system SIRe Competent
Control system SIRe Advanced
Brackets for installing unit horizontally
on a wall. Two are required for 1 and 1.5
metre units, while 2 and 2.5 metre units
need three and 3 metre units need four.
GWB
GWB640
Wall bracket, 1 pcs
AGS5000 A, ambient, unheated (IP23)  1
Type
Voltage
AGS5015A
AGS5020A
AGS5025A
AGS5030A
[V]
230V~
230V~
230V~
230V~
Heat
output
[kW]
0
0
0
0
Airflow
[m³/h]
5300
7600
10200
12000
Sound
level
[dB(A)]
48/67
50/69
52/71
53/72
Length
[mm]
1515
2010
2520
3030
AGS5000 WL, water heated (IP23)  2
Type
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AGS5015WL
230V~
25,0
4800
47/66
1515
AGS5020WL
230V~
41,4
7000
49/68
2010
AGS5025WL
230V~
53,7
9400
50/69
2520
AGS5030WL
230V~
64,6
11600
52/71
3030
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
AGS6000
•Recommended installation height 6 m
•Height: 450 mm
•Depth: 766 mm
AGS6000 A, ambient, unheated (IP23)  1
Type
Voltage
AGS6010A
AGS6015A
AGS6020A
AGS6025A
AGS6030A
[V]
230V~
230V~
230V~
230V~
230V~
Type
GWB640, wall bracket
Description
•Recommended installation height 5 m
•Height: 450 mm
•Depth: 766 mm
Heat
output
[kW]
0
0
0
0
0
Airflow
[m³/h]
4700
7100
9300
11600
13000
Sound
level
[dB(A)]
48/67
50/69
51/70
52/71
54/73
Length
[mm]
1010
1515
2010
2520
3030
AGS6000 WL, water heated (IP23)  2
Accessories
Type
AGS5000
Voltage
Heat
Airflow
Sound
Length
output*
level
[V]
[kW]
[m³/h]
[dB(A)]
[mm]
AGS6010WL
230V~
24,5
4200
47/66
1010
AGS6015WL
230V~
29,9
6500
49/68
1515
AGS6020WL
230V~
46,7
8500
50/69
2010
AGS6025WL
230V~
57,7
10600
51/70
2520
AGS6030WL
230V~
68,0
12600
53/72
3030
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
31
3-6m
Air curtains - Industry
R
3 - 12 m
UF600
AC500 is a stable air curtain intended for
use on high industrial and warehouse doors.
The air curtain effectively prevents energy
losses and drafts through the open door and
gives excellent heating comfort. The working
environment is further improved by the air
curtain preventing exhaust emissions, dust
and insects from entering the premises.
AC500 is a narrow and tall, splash proof
air curtain equipped with a honeycomb
grille. The air is blown out at high pressure
through the grille, which results in a
powerful and well defined laminar airflow.
UF600 consists of one or two pillars with inlet
hood, silencers and fans, as well as a floor
channel with its slot at floor level. The pillars
are placed inside or outside the door on either
(or both) sides of the opening. Air at high speed
is pressed out through the narrow slot in the
floor at the door opening.
The width of the slot and the blow angle are
adapted to the opening. Complete slot with
inspection hatch could be custom made. UF600
creates a very effective air barrier at the door
opening, when pressing air at high speed out
through a narrow slot. The air curtain is angled
upwards and gives best possible protection
against colder and heavier air getting into the
building.
Diameter: 700/900 mm
Colour: grey.
CE compliant.
3-6 m
AC500
1 / 1,5 m
•Recommended installation height 5 m
•Height: 785 mm
•Depth: 520 mm
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
•Approved for 220V/1ph/60Hz and 380V/3ph/60Hz. Product
performance for 220V/1ph/60Hz and 380V/3ph/60Hz will
differ from stated data.
AC500, ambient, unheated (IP24)  1
Type
AC501
AC502
Voltage
Heat
output
[V]
[kW]
230V~/400V3~ 0
230V~/400V3~ 0
Airflow
[m³/h]
5200
7700
UF600, ambient, unheated (IPX4)  1
Sound
level
[dB(A)]
63
65
Controls
Level 1
-RTRD7, RTRD14, 5-step fan speed control
-AGB304, position limit switch.
Level 2
-PKDM12, stepless fan speed control.
Type
Description
RTRD7
5-step fan speed control, Max 7 A
RTRD14
5-step fan speed control, Max 14 A
RTRDU7
5-step fan speed control, Max 7 A, high/low speed
PKDM12
Stepless fan speed control, high/low speed
AGB304
Position limit switch, IP44
More information about accessories on page 34.
32
Length
[mm]
1030
1550
Type
Output
Airflow
motor
[kW]
[m³/h]
UF601
8 (2x4)
10500
UF602
11 (2x5,5)
12000
UF603
15 (2x7,5)
15000
UF604
22 (2x11)
18000
UF605
30 (2x15)
23000
UF606*
2x22 (4x11)
36000
*) UF606 correspnds to two UF604.
Amperage Length
[A]
16,0
22,4
28,2
42,0
56,8
2x42,0
Controls
Type
Description
UFC601
UFC602
UFC603
UFC604
UFC605
AGB304
Starter kit UF601
Starter kit UF602
Starter kit UF603
Starter kit UF604
Starter kit UF605
Position limit switch, IP44
[mm]
3900
3900
4145
4145
4145
4145
Max door
dimensions
HxB [m]
3x4
3x6
4x5
4x6
6x6
6 x 12
A i r cur t ai ns
Air curtains - Industry
AGI
•Height: 730 mm
•Depth: 485 mm
•Colour: grey, RAL 9006.
•CE compliant.
•Approved for 380V/3ph/60Hz. Product performance fo
380V/3ph/60Hz will differ from stated data.
Controls
AGI A, ambient, unheated, horizontal mounting, (IP54)  1
Type
AGIH2A
AGIH3A
AGIH4A
AGIH5A
Voltage
400V3~
400V3~
400V3~
400V3~
Heat
Ouput
[kW]
Airflow
[m³/h]
Sound
level
[dB(A)]
0
0
0
0
7000
10500
14000
17500
69
71
72
73
Amperage Length
[A]
2,4
3,5
4,7
5,9
[mm]
1200
1800
2400
3000
AGI A, ambient, unheated, vertical mounting, (IP54)  1
Type
Voltage
Heat
Ouput
[kW]
Airflow
[m³/h]
Sound
level
[dB(A)]
AGIV2A
AGIV3A
AGIV4A
AGIV5A
400V3~
400V3~
400V3~
400V3~
0
0
0
0
7000
10500
14000
17500
69
71
72
73
Amperage Length
[A]
2,4
3,5
4,7
5,9
1,2 / 1,8 / 2,4 / 3,0 m
1,2 / 1,8 / 2,4 / 3,0 m
AGI is a robust air curtain intended for vertical or horizontal
installation in large doorways. With its powerful fans and high
enclosure classification it is specially suitable for industrial
environments.
AGI has a stable and simple design. It is available in four
different lengths of up to 3 metres, which makes it easy to
create a continuous air curtain for large doors. In vertical
installation two units can be put on top of each other.
[mm]
1200
1800
2400
3000
Unit without heating
Level 1
-RTRD7, RTRD14, 5-step fan speed control
-AGB304, position limit switch.
Unit with water heating
Level 1
-RTRD7, RTRD14, 5-step fan speed control
-AGB304, position limit switch.
-T10, room thermostat IP30.
Level 2
-RTRDU, 5-step fan speed control, high/low speed.
-MDC, magnetic door contact with a time relay.
-RTI2, electronic 2-step thermostat
Note! A valve set VR25 (option: TVV25 with SD20) should be
added for a complete control kit.
AGI WL, water heated, horizontal mounting, (IP54)  2
Type
Voltage Heat
Airflow Sound Amperage Length
Ouput*
level
[kW]
[m³/h] [dB(A)] [A]
[mm]
AGIH2WL 400V3~ 33
7000
69
2,4
1200
AGIH3WL 400V3~ 48
10500
71
3,5
1800
AGIH4WL 400V3~ 64
14000
72
4,7
2400
AGIH5WL 400V3~ 81
17500
73
5,9
3000
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
AGI WL, water heated, vertical mounting, (IP54)  2
Type
Voltage
Heat
Airflow Sound Amperage Length
Ouput*
level
[kW]
[m³/h] [dB(A)] [A]
[mm]
AGIV2WL 400V3~ 33
7000
69
2,4
1200
AGIV3WL 400V3~ 48
10500
71
3,5
1800
AGIV4WL 400V3~ 64
14000
72
4,7
2400
AGIV5WL 400V3~ 81
17500
73
5,9
3000
*) Applicable at water temperature 60/40 ºC, air temperature, in +18 ºC.
Type
Description
RTRD7
5-step fan speed control, Max 7 A
RTRD14
5-step fan speed control, Max 14 A
RTRDU7
5-step fan speed control, Max 7 A, high/low speed
T10
Room thermostat, IP30
KRT1900
Room thermostat, IP55
AGB304
Position limit switch, IP44
KUR
Digital time switch, IP55
CBT
Electronic timer, IP44
VR25
Valve set, DN 25 mm
TVV25
2-way control valve, DN 25 mm
SD20
Actuator
More information about accessories on 34 and 63-66.
33
Air curtains - Controls
CB22/
CB32N
CB20/
CB30N
ADSR54
PKDM12
RTRD7
RTRD14
RTRDU7
MDC
MDCDC
AGB304
CB20, control box
RTRD7, 5-step fan speed control
Controls the airflow in 2 steps. Can control several units. Max
input 12 A. IP44.
For AC500 and AGI. With RTRD7 the air velocity is adjusted
in 5 steps for optimum efficiency. The air velocity is set to
accommodate different external conditions. Max input 7 A. IP21.
CB22, control box
Controls the airflow in 2 steps and heat output in 2 steps. Can
control several units. Max input 10 A. IP44.
RTRD14, 5-step fan speed control
For AC500 and AGI. With RTRD14 the air velocity is adjusted
in 5 steps for optimum efficiency. The air velocity is set to
accommodate different external conditions. Max input 14 A.
IP21.
CB30N, control box
Controls the airflow in 3 steps. Can control several units. Max
input 10 A. IP44.
RTRDU7, 5-step fan speed control (high/low speed)
For AC500 and AGI. With RTRDU7 the air velocity is set in 5
steps for maximum efficiency. When the door is closed the fan
runs at a preset low speed to keep the room warm, when the
door is open the fan is preset at a high speed to accommodate
different external conditions. Max input 7 A. IP21.
CB32N, control box
Controls the airflow in 3 steps and heat output in 2 steps. Can
control several units. Max input 10 A. IP44.
CK01E, control kit
Contains control box CB32N and thermostat RTI2.
MDC, magnetic door contact with time relay
Contains control box CB30N and thermostat T10.
Starts the air curtain or increases from low to high speed when
the door is opened. When the door is closed, the fan continues
to run for the preset time (2 s–10 min). This prevents the fan
from starting/stopping continuously and is especially suitable
for doors that are frequently opened. Three alternating volt-free
contacts 10 A, 230 V~ activated when the contacts make. A
MDCDC is included in MDC. IP44.
CK02W, control kit
MDCDC, magnetic door contact
Contains control box CB30N, thermostat TI0 and door contact
MDC.
Indicates door status. Extra MDCDC are used when several doors
are connected to a MDC. IP44.
ADSR54, stepless fan speed control
AGB304, position limit switch
For unheated and water heated air curtains (single phase
supply 230 V~, max 3 A). Controls the motor without causing
disturbing electro magnetic noise. Can be controlled with an
external 0–10 V signal. Max. input 3 A, 230 V~. IP54.
Starts the air curtain or activates a fan speed control when
the door is opened. When the door closes, AGB304 stops the
air curtain or changes fan speed through a fan speed control.
Alternating contact 4 A, 230 V~. IP44.
CK02E, control kit
Contains control box CB32N, thermostat RTI2 and door contact
MDC.
CK01W, control kit
PKDM12, stepless fan speed control
For AC500 and AGI. The appropriate fan speed is set for open
and closed door respectively (high/low speed). The fan speed
can be controlled with an external 0–10 V signal. Max input
12 A. IP54.
Portier
A
CB20
Control box
CB22
Control box
CB30N
Control box
CB32N
Control box
E
AR200
A
E
AD 200/300
W
A
X
X
E
W
AC500
A
W
AGI
A
W
X
X
X
X
X
X
CK01E
Control kit Electric level 1 (CB32N, RTI2)
X
X
CK02E
Control kit Electric level 2 (CB32N, RTI2, MDC)
X
X
CK01W
Control kit Water level 1 (CB30N, T10)
X
CK02W
Control kit Water level 2 (CB30N, RTI2, MDC)
X
ADSR54
Stepless fan speed control
X
X
X*
X*
PKDM12
Stepless fan speed control
X
X
X
X
RTRD7/14/7U
5-step fan speed control
X
X
X
X
MDC
Magnetic door contact with time relay
X
X
X
X
AGB304
*) Max.input 3A.
34
Position limit switch
X
X
X
X
X
X
X
X
Radiant heaters
Heating with radiant heaters is indirect. The heat is
transferred from the radiant heaters at the ceiling to
surfaces such as floors, walls, fixtures and the like,
which in their turn give off heat to the air in the room.
No losses occur on the way from ceiling to floor.
Radiant heating can be compared to ordinary light.
Dispersion and reflection occur in relatively the same
way.
Total heating
Radiant heaters heat people first, then the air. The
operative temperature, being the temperature a person
senses, is therefore a little higher than the actual air
temperature.
For a specific comfort level, use of a radiant heating
system will allow a reduction in air temperature of a couple
of degrees when compared to a conventional system, and
every degree reduction will reduce energy consumption by
approx. 5 %.
Zone and spot heating
With a radiant heating system, different zones within the
same room can have different temperatures. It is therefore
possible to divide any area into smaller zones and maintain
a different comfort level in each zone.
It is also possible to focus the heat on a certain spot, such
as a single workstation. A spot heating application can be
controlled much as spot lighting, with the level of heating
being increased when needed.
There are many advantages with radiant heaters:
Economy
• Heat people and objects first and then the surrounding
air. This allows the temperature to be reduced while
maintaining comfort.
• Produces instant heat, thus much quicker than
traditional heating systems. This is especially useful
outdoor and in buildings that is used occasionally such
as sport centres and country houses.
• Heat at floor level, not at the ceiling.
• Reduced night temperture possible with right controls
thanks to quick heat-up time.
Safety
• By positioning the heaters at high level the risk of getting
in contact with the heater is greatly reduced. The heater
is also protected against damage.
• Some radiant heaters are ideal for premises with fire risk
or highly explosive environments (see radiant heaters
Comfort Panel SZ and SZR).
Simplicity
Complementary heating
• Easy and flexible installation.
As addition to other heating systems and when expanding
an existing system, radiant heaters are often a simple,
inexpensive solution. For a water heated building, putting
up a single or a few electrical heaters is often a smoother
and more flexible solution than extending the water pipe
system.
• Requires a minimum of maintenance.
Cold draught protection
Comfort
A cool surface such as a window has a chilling effect on
the neighbouring air. Radiant heaters provide efficient and
economical protection against cold draughts caused by
windows by heating the window’s surface. The colder the
window, the more radiant heat it will draw. The radiated
heat ”automatically” migrates to where it is most needed,
which facilitates the creation of a comfortable indoor
climate.
Radiant heaters
Radiant heaters create a very equal temperature
distribution between floor and ceiling. The expensive
cushion of overheated air that is easily formed when using
other heating systems can be avoided. In rooms with high
ceilings, radiant heaters give significantly lower energy
consumption.
Space
• By putting the heater on the ceiling, valuable wall and
floor space is saved.
• Using the radiation principle air is not heated directly.
This results in a soft, draught-free, comfortable indoor
climate and an even temperature.
• Does not cause any air movement, as traditional
heating systems often do. Reducing the spread of dust,
bacteria or odours improves the quality of the indoor
environment.
Discreet
• The system is completely silent.
• Mounting on the ceiling or recessed in a false ceiling
gives a discreet heating.
35
Choose the right radiant heater
Radiant heaters are available in various designs – it
is primarily the installation height, the surrounding
environment and the type of heating wanted (see previous
page) that determine the choice of product.
Our radiant heaters are divided into three main
application areas: "Offices, shops and public premises",
"Industry and large premises" and "Outdoors" but most of
them can be used in several application areas as you can
see in below table.
Comfort
To acheive good comfort, it is essential to choose the right
type of radiant heater.
An infrared heater equipped with halogen lamps at
approx. 2000 °C provides intense, short-wave radiation. It
is well-suited to outdoor use or in rooms with high ceilings.
For a similar but softer heat an infrared heater with tube
elements at approx. 750 °C can be used. The heat emitted
from these radiant heaters can be compared to the radiant
heat felt from an open fireplace.
A Thermocassette with a large element surface and a
surface temperature of approx. 100 °C, provides longwave heat radiation, giving comfortable heating and good
dispersion in rooms of normal height (2,7 m).
In a building with high demands on comfort, a larger
number of heaters with low output should be used instead
of fewer heaters with high output.
When zone- or spot heating an area, the heaters should
be placed so that the heat comes from at least two
directions. This is especially important when the heaters
are mounted at lower heights.
Below table and the examples on the following pages will
help you to choose the right radiant heater.
Quick selection guide radiant heaters
Type
Heating
Installation
height
[m]
[W]
[°C]
Offices
Thermoplus
3
3
3
3
3
3
3
3
3
3
2
2
2–3
300-900
180
++
+
Radiant aluminium panel
38
<3
300-600
100
++
+
Heating film
39
2,5–4
600-1500
280
++
+
Radiant aluminium panel
39
3–10
800-2200
340
++
Radiant aluminium panel
40
4–15
3600-4500
350
++
Radiant aluminium panel
40
4,5–20
3000-6000
700
++
Infrared heating rod
41
3–5
1500-4500
2200*3
++
+
Halogen lamp
41
2–2,5
500-2000
750
+
++
Infrared heating rod
42
2–3
1200
2200*3
+
++
Halogen lamp
42
1,8–3,5
1000-1500
2200*3
+
++
Halogen lamp
43
2,5–10
100-580*2
80
Thermocassette
Elztrip EZ100
Elztrip EZ200
Elztrip EZ300
Infrared IR
Infrared IRCF
Infrared CIR
Infrared ELIR
Infrared IH
Comfort panel SZR
Output
Surface
temp.
Application area*1
++
Heating element
Industry Outdoors
+
Radiant steel panel
3–15
50-1900*2
80
++
Radiant steel panel
Comfort panel SZ
*1) Our products are divided into three main application areas: "Offices, shops and public premises", "Industry and large premises" and
"Outdoors" but most products can be used in several application areas.
*2) Per metre, depending on water temperature.
*3) Filament temperature
36
Page
44
45
Radiant heaters
Installation examples for radiant heaters
Frico radiant heaters are available for different kinds of
heating and for different application areas. To facilitate
your choice of product, you will find some typical cases
on the following pages. More detailed information on
important factors to consider when choosing a radiant
heater is found on the previous pages.
Basic criterias:
1.Type of premises – store, warehouse etc.
2.Type of heating - total heating, zone heating,
cold draught protection
3.Height, installation height
4.Mounting: wall or ceiling
5.Connection: with electrical heat or water heat
Offices, shops and public premises
Radiant heaters
Total heating, cafeteria
1.Type of premises: cafeteria
2.Type of heating: total heating
3.Height: 2,80 metres
4.Mounting: ceiling
5.Connection: electrical
Recommendation: Thermocassette can be recessed into
a false ceiling. When using Thermocassette for total
heating, the units should be spread out through the
ceiling for example as shown.
Industry and large premises
Total heating, workshop
1.Type of premises: workshop
2.Type of heating: total heating
3.Height: 5 metres
4.Mounting: ceiling
5.Connection: with electrical heat
Recommendation: A number of EZ300 evenly
positioned over the area to be heated creates
comfortable heat.
Outdoors
Zone heating, restaurant terrace
1.Type of premises: sheltered restaurant
terrace
2.Type of heating: zone heating
3.Height: 2,5 metres
4.Mounting: ceiling (above the tables)
5.Connection: with electrical heat
Recommendation: Several CIR mounted in
line above the tables ensure the comfort for
all customers in deep terraces.
37
Radiant heaters - Offices, shops and public premises
Thermoplus EC
Thermoplus is mounted above windows
and gives an effecient protection against
cold draught. The slim shape also makes it
2-3m
suitable for heating areas with limited space,
like for example bathrooms. Thermoplus can
furthermore be a cost-effective and flexible
alternative to floor heating.
Thermoplus is covered with white enamel
which makes it discreet and schratch-resistant. The slim shape
makes it practically invisible when mounted in the celing
angle.
•Thermoplus is available in three versions:
- Type EC, for dry rooms. Controlled by a separate
thermostat or output control. IP20.
- Type ECVT, for wet rooms. With a built-in cord switch and
thermostat. IP44.
- Type ECV, for wet rooms. Primarily designed for
connection as slave device to ECVT, but can also be
controlled separately using the same methods as for EC.
IP44.
•Brackets for wallmounting are included. Fixtures for ceiling
mounting are extra.
•Max. surface temperature: 180 °C.
•Colour: white, RAL9010, NCS 0502-B.
•CE compliant.
Thermoplus EC for dry rooms (IP20)  3
Type
EC45021
EC45031
EC60021
EC60031
EC75021
EC75031
EC90021
EC90031
Voltage
[V]
230V~
400V~
230V~
400V~
230V~
400V~
230V~
400V~
Heat output
[W]
450
450
600
600
750
750
900
900
LxHxD
[mm]
1076x100x90
1076x100x90
1505x100x90
1505x100x90
1810x100x90
1810x100x90
2140x100x90
2140x100x90
Weight
[kg]
2,6
2,6
3,7
3,7
4,4
4,4
4,8
4,8
Thermoplus ECVT for wet rooms, with built-in switch and
thermostat (IP44)  3
Type
ECVT30021
ECVT55021
ECVT55031
ECVT70021
ECVT70031
Voltage
[V]
230V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
550
550
700
700
LxHxD
[mm]
870x100x90
1505x100x90
1505x100x90
1810x100x90
1810x100x90
Weight
[kg]
2,6
4,3
4,3
5,0
5,0
Thermoplus ECV slave unit to ECVT, for wet rooms (IP44)  3
Type
ECV30021
ECV55021
ECV55031
ECV70021
ECV70031
Voltage
[V]
230V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
550
550
700
700
LxHxD
[mm]
870x100x90
1505x100x90
1505x100x90
1810x100x90
1810x100x90
Weight
[kg]
2,3
4,0
4,0
4,7
4,7
Accessories - Thermoplus
Type
Description
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
TF1
Fixtures for ceiling mounting (2 pcs)
OS1
Protection net 1070 mm
OS2
Protection net 1500 mm
For controls, see pages 46 and 63-64.
Min. distances EC [mm]
Ceiling
Wall / long side of the unit (EC)
Flammable material/ front side (EC)
Flammable material/ lower side (EC)
Floor
38
A
B
C
D
E
60
25
90
25
1800
Radiant heaters - Offices, shops and public premises
Elztrip EZ100
Thermocassette is intended for discreet heating
in offices, bathrooms, schools etc. Designed
for either surface or recessed mounting it
<3m
is well suited for total heating as well as for
spot heating of for example a reception desk.
Mounted in a false ceiling it is well protected
against damage and can easily be moved if
necessary (model with cable and plug).
Recessed mounting make the heater an integral part of the
ceiling.
EZ100 is intended for total and supplementary
heating as well as protection against cold
draughts from windows in environments such as
offices, shops, restaurants etc.
EZ100 is a single panel radiant heater with
clean and simple design that blends well with
electrical fittings.
•Thermocassette is available in two versions:
- HP300/600, for false ceiling systems. IP20.
- HP305/605, standard model with brackets, approved for
rooms where there is risk of fire and recommended for use
in agricultural buildings. IP55.
•The low surface temperature (max. 100 °C) makes
Thermocassette well suited for low ceiling heights. There is
no risk of burns to the person(s) in this vicinity.
•Max. surface temperature: 100 °C.
•Colour: white, RAL 9016, NCS S 0500-N.
•Approved by SEMKO and CE compliant.
Type
HP300
HP600
Voltage
[V]
230V~
230V~
Heat output
[W]
300
600
LxHxD
[mm]
593x30x593
593x30x1193
Weight
[kg]
5,4
10,3
Thermocassette HP with mounting brackets and cable (IP55)  3
Type
HP305
HP605
Voltage
[V]
230V~
230V~
Heat output
[W]
300
600
LxHxD
[mm]
593x30x593
593x30x1193
•Integrated elements and a surface structure for improved
efficiency.
•The heaters are approved for serial connection.
•Fixtures for easy mounting on the ceiling are included.
•Bracket for wall mounting (EZMVK) is available as an
accessory.
•Max. surface temperature: 280 °C.
•Heating panel of naturally anodised aluminium.
•Colour: white, RAL9010, NCS 0502-B.
•Approved by SEMKO and CE compliant.
Elztrip EZ100 (IP44)  3
Type
EZ106N
EZ111N
EZ115N
Thermocassette HP for false ceilings, with cable and plug
(IP20)  3
Weight
[kg]
5,8
10,7
2,5 - 4 m
Radi an t h e at e r s
Thermocassette HP
Voltage
[V]
230V~
230V~
230V~
Heat output
[W]
600
1050
1500
LxHxD
[mm]
870x50x150
1470x50x150
1950x50x150
Weight
[kg]
3,2
5,4
6,95
Accessories - EZ100
Type
Description
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
CIRT
Stepless output control with timer, IP44
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
EZMVK
Wall mounting bracket
For controls, see pages 46 and 63-64.
Accessories - Thermocassette
Type
Description
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
74701
Wire mounting kit
For controls, see pages 46 and 63-64.
Min. distances EZ100 [mm]
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
50
50
50
500
1800
Min. distances HP [mm]
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
80
50
50
500
1800
80
50
500
1800
39
Radiant heaters - Industry and large premises
Elztrip EZ200
Elztrip EZ300
EZ200 is intended for total and supplementary
heating as well as protection against cold
draughts from windows in environments such
as, department stores, assembly halls, industrial
premises etc.
EZ200 is a double panel radiant heater with
clean and simple design that blends well with
electrical fittings.
EZ300 is intended for total and supplementary
heating in industrial environments such as
warehouses, workshops etc.
EZ300 is a triple panel radiant heater with
discreet and robust design that blends well with
electrical fittings.
3 - 10 m
•Integrated elements and a surface structure for improved
efficiency.
•The heaters are approved for serial connection.
•Fixtures for easy mounting on the ceiling are included.
•Max. surface temperature: 340 °C.
•Heating panel of naturally anodised aluminium.
•Colour: white, RAL 9016, NCS S 0500-N.
•Approved by SEMKO and CE compliant.
Elztrip EZ200 (IP44)  3
Type
EZ208
EZ212
EZ217
EZ222
EZ20831
EZ21231
EZ21731
EZ22231
Voltage
[V]
230V~
230V~
230V~
230V~
400V2~
400V2~
400V2~
400V2~
•Integrated elements and a surface structure for
improved efficiency.
•The heaters are approved for serial connection.
•Fixtures for easy mounting on the ceiling are included.
•Max. surface temperature: 350 °C.
•Colour: Casing of grey alu-zinc coated steel panels with high
corrosion resistance. Heating panel of naturally anodised
aluminium.
•Approved by SEMKO and CE compliant.
Elztrip EZ300 (IP44)  3
Heat output
[W]
800
1200
1700
2200
800
1200
1700
2200
LxHxD
[mm]
683x64x282
923x64x282
1221x64x282
1520x64x282
683x64x282
923x64x282
1221x64x282
1520x64x282
Weight
[kg]
4,9
6,8
8,8
10,7
4,9
6,8
8,8
10,7
Accessories - EZ200
Type
Description
Type
EZ336
EZ345
Voltage
[V]
230V3~/400V3N~
230V3~/400V3N~
Heat output
[W]
3600
4500
Min. distances EZ200 [mm]
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
Type
Description
S123
Manual switch for 1-2-3 steps, IP42
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
KRT1900
Room thermostat, IP55
CBT
Electronic timer, IP44
For controls, see pages 46 and 63-64.
Min. distances EZ300 [mm]
80
150
150
600
1800
LxHxD
[mm]
1670x63x420
2030x63x420
Accessories - EZ300
ERP
Electric heating control, master, IP20
ERPS
Electric heating control, slave, IP20
CIRT
Stepless output control with timer, IP44
T10
Room thermostat, IP30
TKS16
Room thermostat with knob and 1-pole main switch, IP30
TD10
Room thermostat with digital display, IP30
KRT1900
Room thermostat, IP55
For controls, see pages 46 and 63-64.
40
4 - 15 m
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
115
250
250
700
1800
Weight
[kg]
20
24
Radiant heaters - Industry and large premises
Halogen infrared heater IRCF
IR is suitabe for total or supplementary heating
of premises with large volume and high ceilings.
It can also be used outdoors for example on
sport arena stands or to keep loading bays dry
and frostless.
IR has a robust industrial design.
IRCF is especially designed for spot heating
of premises with large air volumes, such as
churches, aircraft hangars and marquees. With
its high efficiency and compact size it is perfect
for many difficult applications.
IRCF has a discreet and compact design.
Equipped with one to three halogen lamps and
with glossy finished reflectors.
4,5 - 20m
•Reflectors of shiny anodised aluminium for
optimal heat distribution.
•The mounting hinges allow the heater to be angled in five
different positions.
•Max. surface temperature: 700 °C.
•Colour: Casing of grey alu-zinc coated steel panels with high
corrosion resistance.
•Approved by SEMKO and CE compliant.
Industrial infrared heater IR (IP44)  3
Type
Voltage
Heat output LxHxD
Weight
[V]
[W]
[mm]
[kg]
IR3000
400V3N~*
3000
1125x83x358
9,0
IR4500
400V3N~*
4500
1500x83x358
11,1
IR6000
400V3N~*
6000
1875x83x358
13,2
*) Can be connected without neutral, but then without output steps. With
neutral, one elements at a time can be connected.
3 - 10 m
Radi an t h e at e r s
Industrial infrared heater IR
•Equipped with one to three halogen lamps and with glossy
finished reflectors.
•Easy mounting with mounting bracket on the wall or ceiling.
The heater can be angled.
•Protection grille available as an accessory.
•Max. element temperature:2200 °C.
•Colour: grey, RAL 9006.
•CE compliant.
Infrared heater IRCF (IP20)  3
Type
Voltage
[V]
230V~
230V~
230V~/400V3~
IRCF1500
IRCF3000
IRCF4500
Heat output
[W]
1500
3000
4500
HxWxD
[mm]
490x230x140
490x375x140
490x515x140
Weight
[kg]
2,0
2,5
3,0
Accessories - IRCF
Accessories - Industrial infrared heater IR
Type
Description
S123
Manual switch for 1-2-3 steps, IP42
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
KRT1900
Room thermostat, IP55
CBT
Electronic timer, IP44
IRG3000
Protection grille IR3000
IRG4500
Protection grille IR4500
IRG6000
Protection grille IR6000
For controls, see pages 46 and 63-64.
Min. distances IR [mm]
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
Type
Description
Manual switch for 1-2-3 steps, IP42
Electronic timer, IP44
Electronic thermostat with concealed knob
Electronic thermostat with visible knob
Capillary room thermostat, IP55
Extra lamp
Protection grille for IRCF1500. IRCF3000 require 2 pcs,
IRCF4500 require 3 pcs.
For controls, see pages 46 and 63-64.
S123
CBT
T10
TK10
KRT1900
LIRCF
IRCG1
Min. distances IRCF [mm]
A
B
C
D
E
400
400
400
700
2300
A
A
B
B
C
C
Ceiling
Wall
Floor
A
B
C
500
50
2300
Ceiling
Wall
Floor
A
B
C
180
500
2300
41
Radiant heaters - Outdoors
Infrared heater CIR
Halogen infrared heater ELIR
CIR provide comfort all year around on
terraces, balconies and open-air restaurants.
CIR can also be used for spot heating in
workshops and warehouses. Requires no
protection against bad weather and has fiveyear corrosion warranty.
CIR is discreet with its slim design and
silent, invisible operation and needs little
space to fit in.
ELIR gives an intense heat suitable for all
outdoor applications and rough industrial
premises. While ELIR is light, stable and
2-3 m
portable it is also well suited for temporary
heating on building sites etc. With its
concentrated heat it is a good complement
to dehumidifiers for drying in areas
damaged by water. High protection class
(IP65) makes it possible to install the heater in almost any
environment.
ELIR has a thorough design in a compact format. Simple,
robust and light (1 kg). ELIR has no protective glass which
means 10–15 % higher efficiency compared to a heater with
glass with the same protection class.
2 - 2,5 m
•Infrared heater CIR is available in two versions:
- CIR100 with outputs between 500 and 2000 W.
- CIR200 with the same outputs and built-in switch.
•Reflectors of high-gloss polished aluminium with maximum
resistance against corrosion.
•Grey terminal boxes of heat and weather resistant
polycarbonate.
•Adjustable mounting brackets for easy mounting on the wall
or ceiling.
•Max. surface temperature: 750 °C.
•Colour: white, RAL 9002, NCS 1502-Y.
•Approved by SEMKO and CE compliant.
Infrared heater CIR without built-in switch (IP24)  3
Type
CIR10521
CIR11021
CIR11031
CIR11521
CIR11531
CIR12021
CIR12031
Voltage
[V]
230V~
230V~
400V2~
230V~
400V2~
230V~
400V2~
Heat output
[W]
500
1000
1000
1500
1500
2000
2000
LxHxD
[mm]
710x44x94
1250x44x94
1250x44x94
1755x44x94
1755x44x94
2180x44x94
2180x44x94
Weight
[kg]
1,5
2,2
2,2
3,0
3,0
3,7
3,7
Infrared heater CIR with built-in switch (IP24)  3
Type
CIR20521
CIR21021
CIR21031
CIR21531
CIR22031
Voltage
[V]
230V~
230V~
400V2~
400V2~
400V2~
Heat output
[W]
500
1000
1000
1500
2000
LxHxD
[cm]
710x44x94
1250x44x94
1250x44x94
1755x44x94
2180x44x94
•All parts are anti-corrosive.
•Casing/reflectors of high-gloss polished aluminium with
maximum resistance against corrosion.
•ELIR is mounted on the wall with the accompanying
mounting bracket or suspended from the ceiling. It can also
be mounted on a stand for portable use. Suspension details
and stand are extra.
•Grey terminal boxes of heat and weather resistant plastic.
Colour: RAL 7035.
•Max. surface temperature: 2200 °C.
•CE compliant.
Infrared heater ELIR (IP65)  3
Type
ELIR12
Voltage
[V]
230V~
Heat output
[W]
1200
Type
Description
ELIRC
Chain for ceiling mounting
ELIRS
Floor stand (tripod) with bracket for ELIR included
ELIRB
Universal bracket when using any floor stand (i.e. tripod)
IREL12
Extra lamp
CBT
Electronic timer, IP44
For controls, see pages 46 and 63-64.
Description
CIRT
Stepless output control with timer, IP44
CBT
Electronic timer, IP44
For controls, see pages 46 and 63-64.
Min. distances ELIR [mm]
Min. distances CIR [mm]
150
150
300
700
42
1800
Weight
[kg]
1,0
Accessories - ELIR
Weight
[kg]
1,5
2,2
2,2
3,0
3,7
Accessories - CIR
Type
LxHxD
[mm]
712x112x83
Ceiling
Wall / long side of the unit
Wall / short side of the unit
Flammable material
Floor
A
B
C
D
E
400
600
600
1000
1800
Radiant heaters - Outdoors
Halogen infrared heater IH
•IH is available in two versions:
- IHW provides wide heat distribution (60°),
recommended installation height 1.8 – 2.5 m.
- IHF provides directed heat distribution (40°),
recommended installation height 2.3 – 3.5 m.
•IH consists of a halogen lamp with a very high
intensity and a highly-polished reflector for optimum
heat distribution.
•Gives 10-15 % higher efficiency than a glass fronted
heater of the same enclosure.
•Bracket for wall mounting. Can also be suspended
from the ceiling or mounted on e.g. a parasol or a
post. Other mounting alternatives are available as
accessories.
•Max. element temperature:2200 °C.
•Colour: grey, RAL 9006.
•Approved by SEMKO and CE compliant.
Accessories - IH
Type
Description
CBT
IHUB
IHXH
IHXL
IHT
IHTW
Electronic timer, IP44
Universal bracket for IH
Drooping extension bracket for high level mounting
Arching extension bracket for low level mounting
Triple bracket
Set of three bright galvanized wires for easy hanging
of IHT
Post for freestanding installation
Halogen lamp 1000W
Halogen lamp 1500W
IHP
IHL1000
IHL1500
Radi an t h e at e r s
Halogen infrared heater IH is the perfect
choice for exposed outdoor environments
where design is important, for example,
1,8 - 3,5 m
balconies, pavement cafés, etc. IH can also be
used as local heating in large premises such as
churches, industries and warehouses.
IH is easy to position thanks to its compact
design. The discreet and appealing look
makes it suitable for outdoor environments with design
demands.
IHXH
IHXL
Infrared heater IHW with wide heat distribution (IPX4)  3
Type
IHW10
IHW15
Voltage
[V]
230V~
230V~
Heat output
[W]
1000
1500
LxHxD
[mm]
500x77x169
500x77x169
Weight
[kg]
1,9
1,9
Infrared heater IHF with directed heat distribution (IPX4)  3
Type
IHF10
IHF15
Voltage
[V]
230V~
230V~
Heat output
[W]
1000
1500
LxHxD
[mm]
500x77x169
500x77x169
Weight
[kg]
1,9
1,9
IHUB
IHP + IHT
Min. distances IH [mm]
A
IHT + IHTW
B
C
Ceiling
Flammable material
Floor
A
B
C
200
1000
1800
43
Radiant heaters- water heated
Comfort Panel SZR
Comfort Panel SZR is used for water supplied
heating/cooling systems. It can be mounted
free hanging or integrated in false ceilings and
perfectly suits in fine environments such as
2,5 - 10 m
offices, shops, etc.
Discreet flat satin finished surface that
matches most false ceiling panel designs. A
perfect symmetri can be created with heating/
cooling panels in combination with non active panels.
•Comfort Panel SZR is available in following versions:
- SZRxxxP for recessed mounting in false ceilings.
- SZRxxxM for free hanging mounting.
•The panels are available in five lengths with three different
pipe settings. The lengths can be combined to a total panel
length desired. Non active panels are available.
•Complies to EN14037 which is based on the EU Construction
Product Directives 89/106/CEE. EN14037 is compulsory for a
CE mark for water heated radiant heaters.
•Max working pressure: 4 bar.
•Max water temperature: 90 °C
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
Insulation 30 mm (included, not
mounted)
Comfort Panel SZR for recessed mounting 
Type*1
SZR060P
SZR120P
SZR180P
SZR240P
SZR300P
SZRN60P
SZRN120P
Heat output*2
[W/pcs]
178
355
534
713
893
Non active
Non active
Weight
[kg]
7
14
21
28
35
4
8
LxHxW
[mm]
595x35x595
1195x35x595
1795x35x595
2395x35x595
2995x35x595
595x35x595
1195x35x595
Suspension
Insulation holding
strip
Comfort Panel SZR for free hanging mounting 
Type*1
Heat output*2
Weight
LxHxW
[W/pcs]
[kg]
[mm]
SZR060M
178
7
595x35x595
SZR120M
355
14
1234x35x610
SZR180M
534
21
1858x35x610
SZR240M
713
28
2482x35x610
SZR300M
893
35
3106x35x610
SZRN60M
Non active
4
610x35x610
SZRN120M
Non active
8
1234x35x610
*¹) The panels are available with three different pipe settings.
*2) Applicable at water temperature 80/60 °C, air temperature +20 °C.
Accessories - Comfort Panel SZR
Type
Description
RTI2
Room thermostat, IP44
T10
Room thermostat, IP30
TVV20/25
2-way control valve, DN 20/25 mm
SD20
Actuator
TRV20/25
3-way control valve, DN 20/25 mm
Suspension accessories are priced on request.
A Comfort Panel handbook with detailed information is available at
www.frico.se. Further information can also be obtained by contacting
Frico.
44
Recessed mounting in false ceiling
Radiant heaters- water heated
Comfort Panel SZ
3 - 15 m
Radi an t h e at e r s
Comfort Panel SZ is the ideal system solution
for water supplied heating of larger buildings
such as industrial buildings, commercial
buildings and sports centres. Comfort Panel SZ
is suitable for both high and low installation,
and extremely high installations are possible
with pressurized hot water. •Complies to EN14037 which is based on the
EU Construction Product Directives 89/106/CEE. EN14037 is
compulsory for a CE mark for water heated radiant heaters.
• For ceiling mounting in panel lengths of 4 meters up to 120
meters.
•Max working pressure: 10 bar (special version: 16 bar).
•Max water temperature: 120 °C (special version: 180 °C).
•Colour: white, RAL 9016, NCS S 0500-N or light grey,
RAL 9002, NCS 1502-Y. Other colours available on request.
•CE compliant.
Comfort Panel SZ max 120 °C  2
Type
Heat output* Weight
Width
[W/m]
[kg/m]
[mm]
SZ23
162
4
300
SZ26
289
8
600
SZ29
406
12
900
SZ212
543
16
1200
SZ33
194
6
300
SZ36
345
12
600
SZ39
501
18
900
SZ312
639
24
1200
*) Applicable at water temperature 80/60 °C, air temperature +15 °C.
Comfort Panel SZ special max 180 °C  2
Type
Heat output* Weight
Width
[W/m]
[kg/m]
[mm]
SZ23SP
267
5
300
SZ26SP
477
10
600
SZ29SP
667
15
900
SZ212SP
870
20
1200
SZ33SP
324
7
300
SZ36SP
574
14
600
SZ39SP
790
21
900
SZ312SP
1005
28
1200
*) Applicable at water temperature 130/70 °C, air temperature +15 °C.
Accessories - Comfort Panel SZ
Type
Description
RTI2
T10
TVV20/25
SD20
TRV20/25
Room thermostat, IP44
Room thermostat, IP30
2-way control valve, DN 20/25 mm
Actuator
3-way control valve, DN 20/25 mm
1. Threaded male connection (Ø 1/2” - 3/4” - 1” - 1.1/4”)
2. Connection for drain valve Ø 3/8”
3. Connection for air vent. valve Ø 3/8”
4. First or end header
5. Steel pipe Ø 1/2”
6. Radiant panel
7. Suspension bracket
8.Insulation
9. Side edging strip
10. Insulation retaining clip
11. Anti-convective side skirts (accessory)
12. Skirt hook
13. Pipe ends adapted for press fitting or compression fitting
or belled end for welding
14. Make-up joint
15. Make-up joint between panel and header (accessory)
A Comfort Panel handbook with detailed information is available at
www.frico.se. Further information can also be obtained by contacting Frico.
45
Radiant heaters - Controls
ERP, electric heating control
CIRT, stepless output control with timer
Stepless pulse control intended for single phase (3600W/230V)
or two phase (6000W/400V2~) electric heaters. Cannot control
3 phase loads. Pulse time 60 secs. Triac control (quiet control).
Integrated temperature sensor. External sensors available as
an accessory. Save reduction function via external connection
timer (1–10 degrees). For larger power outputs a slave unit
(ERPS) can be connected. Each ERPS can handle the same
power as ERP.
Stepless output control with timer, primarily intended for
infrared heaters and other radiant heaters. Intended for single
phase (3600W/230V~) or two phase (6000W/400V2~) electric
heaters. Especially suited for spot amd zone heating. The heat
contribution is regulated for best comfort (25-100 %). The
built-in timer can be set for 0.5 to 4 or 4 to 24 hours. High
protection class (IP44).
Electric heating control ERP (IP20) 
Output control CIRT (IP44) 
Type
ERP
ERPS
Voltage
[V]
230/400V~
230/400V~
HxWxD
[mm]
153x93x40
153x93x40
Type
CIRT
Voltage
[V]
230/400V2~
HxWxD
[mm]
155x87x43
Accessories ERP
Type
Description
ERPRG
ERPGG
Room sensor ERP
Floor/duct sensor ERP
S123, manual switch for 1-2-3 steps
Controls the output in three steps 0-1/3-2/3-3/3.
Manual switch S123 (IP44) 
Type
S123
46
Voltage
[V]
230/400V3~
HxWxD
[mm]
72x64x46
Fan heaters
For decades Frico has been the world leader in fan
heater design. Today we have a complete range of
high quality equipment modelled on the demanding
climate of Scandinavia. Frico’s worldwide distribution
network encounters many different environmental
conditions, such as storage rooms, pump rooms,
building sites, mines, sports centres, shops, drying
rooms, stables, boats, etc.
We are proud of the worldwide acclaim we have
gained through our line of fan heaters. They are
known as reliable and long-lasting products. The
heaters are also robust and will withstand rough
treatment in aggressive environments, at the same
time having the lowest sound level on the market.
Exceptionally quiet
One of the most important tasks in our product development,
is the construction of low noise fan heaters.
At our plant in Skinnskatteberg, Sweden, you will find one
of the most sophisticated air and sound laboratories in Europe,
staffed by highly skilled technicians making it possible to
manufacture products of the finest quality.
Lots of power, small investment
Fan heaters
Compared to other heating systems, the investment cost for
fan heaters is low. Frico fan heaters give you lots of power for
the money.
Compact and robust
Frico fan heaters are compact and light. Therefore they are
easy to carry or can easily be mounted on the wall.
The heaters are also very robust and withstand heavy
handling in aggressive environments.
Electricity or water?
Frico fan heaters are available for electrical or water heating you have the choice!
Heating and ventilation
A great advantage of fan heaters is the option of combining
heating and ventilation. Mixing cabinets for stationary fan
heaters create economic heating and ventilation, by mixing the
return air with fresh air.
47
Fan heaters - electrically heated
Door heater PA1006
Fan heater K21
PA1006 is a compact door heater which heats the incoming
air and gives increased comfort on the inside. When wall
mounted, the unit can act as a high level fan heater.
With its compact construction and timeless design the unit
is easy to place in any doorway. The intuitive controls are
easily accessible, placed on the gable end.
•Compact and easy to position.
•Low sound level.
•The unit is easily angled on the bracket, which is used for
both wall and ceiling mounting.
•Integrated control.
•Designed for permanent installation and is connected via
cable without plug.
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
K21 is a compact and safe fan heater designed for portable use.
Ideal for heating small areas, for example, garages, caravans,
awnings, weekend cottages, offices, patios, etc.
K21 fan heater is small and compact in white metal finish
and is equipped with a solid handle.
Door heater PA1006E03 (IP20)  3
Type
Voltage Output Airflow Sound HxWxD
Weight
steps
level*
[V]
[kW]
[m³/h] [dB(A)] [mm]
[kg]
PA1006E03 230V~
0/1.5/3 230
44
153x164x650 5,3
*) Conditions for sound level measurements, see page 67.
48
•Self-regulating ceramic PTC element that can not be
overheated.
•Intensive and concentrated heat emission. The air is heated
to approx. 65 °C when it passes through K21.
•Equipped with 2 metre long cord with plug for connection to
an earthed outlet socket.
•Thermostat (+5 – +35 °C) and output selector (0/1/2 kW).
•Dimensions HxBxD: 220x160x200 mm.
•Colour: white, RAL 9016, NCS S 0500-N.
•Approved by SEMKO and CE compliant.
Fan heater K21 (IP21)  3
Type
Voltage Output Airflow Sound
[V]
steps
level*
[kW]
[m³/h]
[dB(A]
K21
230V~
0/1/2
90
43
*) Conditions: Distance to unit 5 metres.
HxWxD
Weight
[mm]
220x160x200
[kg]
2,5
Fan heaters - electrically heated
Fan heater Tiger
•The Tiger fan heater is available in the following designs:
- P21 and P31 have a 1.8 m cord with plug for connection to
earthed outlet sockets. Can be hung on the wall.
- P33, P53 and P93 have a 1.8 m cable with CEE-plug.
230V-outlet socket (type E) at the rear. Can be hung on the
wall.
- P153 has a 1.8 m cable with CEE-plug. Can be hung on the
wall.
- P203, P303 and P305 are supplied with a 1.8 m cable
without a plug. P305 can be connected to 440V3~ and
500V3~.
•Low sound level.
•Integrated thermostat with setting range +5 – +35 °C and
output selector.
•Colour: red, RAL 3020, NCS 1090-Y80R.
•CE compliant.
Conditions for sound level measurements, see page 67.
Fan heater Tiger 2–9 kW (IP44)  3
Type
Voltage
Output Airflow Sound HxWxD
Weight
steps
level
[V]
[kW]
[m³/h] [dB(A)] [mm]
[kg]
P21
230V~
0/2
280
41
450x290x390 5,7
P31
230V~
0/2/3
280
41
450x290x390 6,0
P51
230V~
0/3,3/5 480
41
450x290x390 6,4
P33
400V3N~* 0/1,5/3 280
41
450x290x390 6,3
P53
400V3N~* 0/2,5/5 480
40
450x290x390 6,7
P93
400V3N~* 0/4,5/9 720
44
530x350x480 10
*) Also available without neutral and are then called P33-0, P53-0 and
P93-0. These models do not have a 230 V~ socket on the back.
Fan heater Tiger 15 kW (IP44)  3
Type
Voltage
P153
[V]
400V3~
Output
steps
[kW]
0/7,5/15
Airflow Sound
level
[m³/h] [dB(A)]
1120
47
HxWxD
Weight
[mm]
510x410x530
[kg]
16
Fan heater Tiger 20 and 30 kW (IP44)  3
Type
Voltage Output
Airflow
Sound HxWxD
steps
level
[V]
[kW]
[m³/h]
[dB(A)] [mm]
P203
400V3~ 0/10/20
1900/2600 60
590x630x600
P303
400V3~ 0/10/20/30 1900/2600 52
590x630x600
P3053* 440V3~ 0/7,5/15/23 1900/2600 52
590x630x600
500V3~ 0/10/20/30
*) Can be connected to 440V3~ and 500V3~.
Fan heaters
Tiger is a range of robust and compact fan heaters for
professionals with high demands. The Tiger fan heater is
portable, models up to 15 kW can also be hung on the wall.
Tiger 2-9 kW are intended for heating and drying areas such
as garages, workshops and shops.
Tiger 15, 20 and 30 kW are ideal for heating and drying
larger premises such as industrial premises and workshops,
where higher outputs are required.
The Tiger fan heater has a compact and robust sheet steel
design with a red finish. The heavy-duty tubular frame acts as
a well-balanced and ergonomic carrying handle. The design
protects against impact and vibrations and permits use in
exacting environments.
Weight
[kg]
26
30
30
Accessories - Tiger
Type
Description
LT22406
Wall bracket
49
Fan heaters - electrically heated
Elektra - C/F/V/H
Elektra is a range of fan heaters designed for use in demanding
environments. The different models can be used anywhere
from corrosive environments and combustible areas to rooms
with high temperatures as well as onboard ships and offshore
platforms. Elektra is mainly designed for stationary use, yet
can also be used as a portable fan heater.
The Elektra fan heater has a modern design with a stainless
steel outer casing, red grille and red brackets. The brackets
can be rotated, which means Elektra can also be used as a
portable fan heater.
•The Elektra fan heater is available in four designs:
- Elektra C is intended for corrosive and damp
environments, for example, car-wash halls and sewage
works. Outer casing of acid-proof sheet steel. IP65.
- Elektra F has a low element temperature and is approved
for use in combustible areas, for example, joinery
workshops and agricultural buildings. IP65.
- Elektra V is designed to withstand vibrations on ships and
offshore platforms and is approved by Det Norske Veritas.
Also available for 440V/60Hz. IP44.
- Elektra H is designed for rooms with high temperatures, up
to 70 °C. IP44.
•Colour: stainless steel outer casing (Elektra C has an acidproof outer casing). Grille and bracket: red, RAL 3020.
•Approved by SEMKO and CE compliant. Elektra V is
approved by Det Norske Veritas.
Control options
Fan heater Elektra H features an integrated thermostat
with the working range 0 – +70 °C, other models feature an
integrated thermostat with the working range 0 – +35 °C. The
output can be selected using the output selector on the unit or
on the external control panel.
Elektra C / Elektra V
- ELSRT, control box, controls one unit
- ELSRT4, control box, controls four units
Elektra F
- ELS, control box, controls one unit
Elektra H
- ELRT, room thermostat
Fan heater Elektra C for corrosive and humide environments (IP65)  3
Type
Voltage
ELC331
ELC633
ELC933
ELC1533
Airflow HxWxD
Weight
[V]
230V~
Output
steps
[kW]
0/1,5/3
[m³/h]
400
[mm]
375x300x340
[kg]
13
400V3~
400V3~
400V3~
0/3/6
0/4,5/9
0/7,5/15
1000
1000
1300
445x375x430
445x375x430
445x375x430
20
20
20
Fan heater Elektra F for combustible areas (IP65)  3
Type
Vvoltage
ELF331
ELF633
ELF933
[V]
230V~
400V3~
400V3~
Output
steps
[kW]
0/1,5/3
0/3/6
0/4,5/9
Airflow HxWxD
Weight
[m³/h]
400
700
1000
[kg]
13
13
20
[mm]
375x300x340
375x300x340
445x375x430
Fan heater Elektra V for ships and offshore platforms (IP44)  3
Type
Voltage
ELV331
ELV3333
ELV3344
ELV5333
ELV6344
[V]
230V~
400V3~
400/440V3~
400V3~
400/440V3~
Output
steps
[kW]
0/2/3
0/1,5/3
0/1,8/3,6
0/2,5/5
0/3/6
Airflow HxWxD
Weight
[m³/h]
400
400
400
700
700
[kg]
13
13
13
13
13
[mm]
375x300x340
375x300x340
375x300x340
375x300x340
375x300x340
50
Voltage
ELH633
ELH933
[V]
400V3N~
400V3N~
Output
steps
[kW]
0/3/6
0/4,5/9
Airflow HxWxD
Weight
[m³/h]
1000
1000
[kg]
20
20
[mm]
445x375x430
445x375x430
ELSRT4
ELS
ELRT
ELSRT/ELSRT4, control panel
The required output and temperature can be set on the control
panel. Integrated thermostat, +5 – +35 °C. Used for external
control, for example, when installed high on a wall. ELSRT
controls only one unit. ELSRT4 can control up to four units.
IP65.
ELS, control panel start/stop
Control panel that starts/stops the fan, for external control, for
example, when installed high on a wall. Only one unit can be
controlled from one control panel. IP65.
ELRT, room thermostat
Capillary tube thermostat with visible dial. Setting range
0 - +70 °C. Max. breaking current: 16 A. IP44.
Accessories - Elektra
Type
Description
Control box with thermostat for ELC and ELV, start/stop,
175x150x100 mm, IP65
ELSRT4
Control box with thermostat for ELC and ELV, start/stop,
for 4 units, 255x360x110 mm, IP65
ELS
Control box for ELF, start/stop, 105x70x80 mm, IP65
ELRT
Room thermostat for ELH, 175x150x100 mm, IP44
KRT1900
Room thermostat, IP55
For controls, see pages 63-64.
ELSRT
Fan heater Elektra H for high temperatures (IP44)  3
Type
ELSRT
Fan heaters - electrically heated
Fan heater Cat
Cat is a range of compact and quiet fan heaters for stationary
use. It is ideally suited for small stockrooms, in a garage,
workshop or shop. The mixing cabinet (accessory) allows
heating and ventilation to be combined, through mixing the
return air and outdoor air.
The Cat fan heater has a classic clean design in white
enamelled sheet steel. It is small and unobtrusive and with
that easy to position.
CMB35 with Cat
Fan heater Cat (IP44)  3
Type
Voltage
Output
steps
[kW]
0/1,5/3
Airflow Sound HxWxD
level
[m³/h] [dB(A)] [mm]
280
41
255x335x276
Weight
[V]
[kg)
230V~
6,3
400V3N~
C5
400V3N~ 0/2,5/5
480
40
255x335x276 6,7
C9
400V3N~ 0/4,5/9
720
44
315x405x335 10,2
*) C3 can be connected for 230V~ and 400V3N~. Other models should
not be connected for single phase, 230V~.
C3*
EV300
EV300, output selector
Output selector with output steps 0-1/2-1/1. IP44.
CMB35, mixing cabinet
Mixing cabinet for C3 and C5. Save energy by mixing the
outdoor air with the return air in individually selected
proportions. An outer wall grille, a walling-in frame and a hand
controller are supplied with the mixing cabinet.
Fan heaters
•Low sound level.
•Wall bracket with 10° tilt angle for good heat distribution.
•Integrated thermostat with setting range +5 – +35 °C and
output selector. External control, for example, thermostat
and timer is possible.
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
TP3/5 and TP9, cover panel for switches
Covers the switches on the heater and prevents changes in the
settings.
Accessories - Cat
Control kits Cat
Built-in control:
The built-in thermostat controls fan speed and heat, or
heat only. The choice is made with the mode selector.
The output can be controlled via the built-in output
selector (0-1/2-1/1).
External regulation:
- T10/TK10 room thermostats
- EV300, output selector
- CBT, electronic timer
Type
Description
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
TKS16
Room thermostat with knob, 1-pole switch, IP30
KRT1900
Room thermostat, IP55
EV300
Output selector, IP44
CBT
Electronic timer, IP44
KUR
Digital time switch, IP55
CMB35
Mixing cabinet for C3 and C5
TP3/5
Cover panel for switches for C3 and C5
TP9
Cover panel for switches for C9
For controls, see pages 63-64.
Conditions for sound level measurements, see page 67.
51
Fan heaters - electrically heated
Fan heater Panther 6-15
Fan heater Panther 20-30
Panther 6-15 is a range of very quiet and efficient fan heaters
for stationary use. They are intended for heating, drying and
ventilation in e.g. workshops, sport halls, shops, assembly
rooms and drying rooms. The mixing cabinet (accessory)
allows heating and ventilation to be combined, through mixing
the return air and outdoor air.
The Panther fan heater has a classic clean design in white
enamelled sheet steel.
Panther 20–30 is a range of powerful and quiet fan heaters
for stationary use. They are intended for heating, drying and
ventilation of large premises, for example, industries. The
mixing cabinet (accessory) allows heating and ventilation to be
combined, through mixing the return air and outdoor air.
The Panther fan heater has a classic clean design in white
enamelled sheet steel.
•Low sound level.
•Supplied with wall bracket that makes it possible to direct
the airflow down and to the side.
•Time delay between the output steps.
•Integrated thermostat with setting range +5 – +35 °C,
possibility to connect an external thermostat.
•External control panel PP15 (ordered separately) with
master/slave function, for up to six units gives good and
simple control.
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
Fan heater Panther 20 and 30 kW (IP44)  3
Fan heater Panther 6-15 kW (IP44)  3
Type
Voltage
Output Airflow
Sound
steps
level
[V]
[kW]
[m³/h]
[db(A)]
SE06
400V3N~ 0/3/6
900/1300 39/47
SE09
400V3N~ 0/4,5/9 900/1300 39/47
SE12
400V3N~ 0/6/12
900/1300 39/47
SE15
400V3N~ 0/7,5/15 900/1300 39/47
SE135 440V3~
0/5/10
900/1300 39/47
500V3~* 0/7/13,5 900/1300
*) Can be connected to 440V3~ and 500V3~.
HxWxD
Weight
[mm]
520x450x510
520x450x510
520x450x510
520x450x510
520x450x510
520x450x510
[kg]
21
22
22
22
23
Control kits Panther 6 -15 kW
Fan speed and thermostat control:
- RTI2 or KRT2800, 2-step room thermostats
- PP15, control box, controls the output in two steps and
the airflow in three steps.
Automatic temperature control:
- PTA, automatic temperature control
Control of mixing cabinet:
- PHR01, control lever, manual damper control or
- PSA01, automatic damper and temperature control
- PSM01, damper motor, is used in combination
with PSA01 when several mixing cabinets should be
controlled
52
•Supplied with wall bracket that makes it possible to direct
the airflow down and to the side.
•Time delay between the output steps.
•Post-running thermostat for efficient cooling.
•External control panel PP20/30 (ordered separately) with
master/slave function, for up to six units, and external
thermostat, for example, RTI2 gives good and simple control.
•Colour: white, RAL 9016, NCS S 0500-N.
•CE compliant.
Conditions for sound level measurements, see page 67.
Type
Voltage
Output
Airflow
Sound
steps
level
[V]
[kW]
[m³/h]
[db(A)]
SE20 400V3N~ 0/10/20
1900/2600 52/60
SE30 400V3N~ 0/10/20/30 1900/2600 52/60
SE305 440V3~
0/7,5/15/23 1900/2600 52/60
500V3~* 0/10/20/30 1900/2600
*) Can be connected to 440V3~ and 500V3~.
HxWxD
Weight
[mm]
576x478x545
576x478x545
576x478x545
576x478x545
[kg]
27
31
32
Control kits Panther 20 - 30 kW
Fan speed and thermostat control:
- RTI2 or KRT2800, 2-step room thermostats
- PP20, control box, controls the output in two steps and
the airflow in two steps (SE20)
- PP30, control box, controls the output in three steps
and the airflow in three steps (SE30, SE305).
Automatic temperature control:
- PTA, automatic temperature control
Control of mixing cabinet:
- PHR01, control lever, manual damper control or
- PSA01, automatic damper and temperature control
- PSM01, damper motor, is used in combination
with PSA01 when several mixing cabinets should be
controlled
Fan heaters - electrically heated
PTRP
4h
2h
1h
12
CBT
CBT
TTF140
PTA01
PSA01
PP15/20/30, control box
The desired output and fan speed can be set on the control
box. Up to 6 units can be controlled by one control box.
Protection class: IP44.
PTA01, automatic temperature control
PTA01 can be used to lower the heat when necessary
(1–10°C), for example at night or weekends. The control
consists of an electronic timer and thermostat with an external
sensor. The timer alternates between day and night mode.
Protection class: IP55.
PHR01, control lever for mixing cabinet
Used with the mixing cabinet, if you wish to control the
damper manually. The pull-rod (not included) for the lever
should have a diameter of 8 mm.
PSA01, automatic damper and temperature regulator
Used on the mixing cabinet. Lowers the temperature and
reduces the amount of outdoor air during periods with a low
requirement. Consists of timer (weekly timer), thermostat
with external sensor, potentiometer and damper motor.
Exhaust air fans can possibly be controlled from the automatic
system. One damper motor (PSM01) included. IP55.
KRT1900
PBS01/02
Accessories Panther 6-12, 20 and 30 kW
Type
Description
PP15
Control box SE06 - SE15, IP44
PP20
Control box SE20, IP44
PP30
Control box SE30 and SE305, IP44
PTA01
Automatic temperature control, IP55
PBS01
Mixing cabinet SE06 – SE15
PBS02
Mixing cabinet SE20, SE30 and SE305
PHR01
Control lever for mixing cabinet
PSM01
Damper motor, IP54
PLR15
Air director SE06 – SE15
PLR30
Air director SE20, SE30 and SE305
PSA01
Automatic damper and temp. control, IP55
PTRP
Drying room kit without fan heater
PFF15
Exhaust air fan SE06 – SE15, IP54
PFF30
Exhaust air fan SE20, SE30 and SE305, IP54
KRT2800
2-step room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
CBT
Electronic timer, IP44
KUR
Digital time switch, IP55
For controls, see pages 63-64.
Fan heaters
PP15/20/30
PSM01, damper motor
Used in combination with PSA01 when several mixing cabinets
should be controlled. (1 damper motor is included in PSA01.)
Protection class: IP54.
PBS01/02, mixing cabinet
Saves energy by mixing return air with fresh air in preset
proportions. The mixing cabinet is delivered with a wall frame
and outer wall grille.
PLR15/30, air director
The air director directs the airflow vertically or laterally. PLR
is snapped on the front of the heater. Torsional (turning) angle
0–35°.
PFF15, exhaust air fan
Can be used with fan heater/mixing cabinet to obtain good
ventilation. Airflow approx. 1400 m³/h. Protection class: IP54.
PFF30, exhaust air fan
Can be used with fan heater/mixing cabinet to obtain good
ventilation. Airflow approx. 2600 m³/h. Protection class: IP54.
PTRP, drying room kit
Consists of exhaust air fan TTF140 with flexi hose and
connection sleeve, thermostat KRT1900 and timer CBT. The
exhaust air fan works alternately with, for example, a fan
heater, which gives the shortest possible drying time and
minimal energy consumption. Supplemented with a fan heater
from the Panther range with output 6-12 kW.
53
Fan heaters - water heated
Fan heater SWH
SWH belongs to a new generation of intelligent fan heaters
with SIRe integrated controls. SWH and SIRe together can
provide fully automatic room heating, adaptable to each area
of use.
SWH is suitable for use in premises where fan heaters are
traditionally used, such as industrial buildings, as well as
environments with low sound requirements.
•Integrated control system SIRe.
•Very low sound level.
•Five fan speeds.
•Mounted on the wall or ceiling.
•Intended for water temperatures up to +125 °C and 10 bar in
standard design.
•Colour: RAL 9016, NCS S 0500-N (white). Aluminium
louvres.
•CE compliant.
Fan heater SWH (IPX4)
Type
Output*
Airflow
Sound HxWxD
Weight
level
[kW]
[m³/h]
[dB(A)] [mm]
[kg]
SWH02
12
1120
39
525x515x320
15
SWH12
20
1810
48
600x535x340
19
SWH22
33
3260
55
725x680x370
27
SWH32
51
5860
58
850x820x450
46
SWH33
66
5420
58
850x820x450
46
*) Applicable at water temperature 80/60 °C, air temperature, in +15 °C
Control options
SWH is supplied with an intelligent and well designed low
voltage control system SIRe which can be customised for each
unique application and environment. The control system is
pre-installed in SWH with an integrated PC board. If more than
one SWH should be controlled by a single SIRe, an additional
modular cable SIReCC per unit is needed. Cables between
units can easily be joined together by using joint piece
SIReCJ. SIRe is supplied pre-programmed with quick fit plug
connections and is very easy to use and install.
SIRe learns the requirements and can provide fully
automated room heating with calendar function and selectable
switch off at set temperatures for up to nine units. Using SIRe
no more energy is consumed than necessary. Because the fan
speed is adapted , the sound level is optimized and is never
higher than is necessary for comfort. With SIRe Advanced
it is possible to choose between Eco and Comfort mode
dependent on whether energy savings or optimal comfort has
been prioritised. SIRe Advanced can also be used for simple
and safe ventilation solutions using mixing cabinets, control
is fully automatic and also has built-in frost protection. There
are three different levels with different functionality to choose
from, Basic, Competent or Advanced. The SIRe control system
can be supplemented with a valve kit for a complete solution.
Functions SIReB Basic
•Manual regulation of the fan and temperature
•Automatic control of fan speed and temperature with
integrated thermostat.
Functions SIReFC Competent
•All functions for Basic
•Calendar function
•Filter alarm
•Simple BMS control - on/off, fan speed and alarm functions
Functions SIReFA Advanced
•All functions for Competent
•Eco mode - extra energy-efficient mode
•Comfort mode - when comfort is important
•Advanced BMS control
•Max limit of return water temperature.
•Stepless heat control.
•Possibility to use an external filter guard.
•Model (SIReFAWM) For fully automatic control of ventilation
and heating with mixing cabinet. One SIReFAWM per unit is
needed. Integrated frost protection.
Control - Fan heater SWH
54
Conditions for sound level measurements, see page 67.
Type
Description
SIReB
SIReFC
SIReFA
SIReFAWM
Control system SIRe Basic
Control system SIRe Competent for fan heaters
Control system SIRe Advanced for fan heaters
Control systemSIRe Advanced for fan heaters with
mixing cabinet
Fan heaters - water heated
SIReRTX
SIReUR
SIReWTA
SIRe Competent /Advanced
Included in SIReB Basic:
•SIReUB1, control unit. Wall unit cover included.
•SIReCC, modular cable, RJ12(6p/6c), 5 m
Options:
•SIReRTX, external room temperature sensor, RJ11 (4p/4c),
10 m
•VOS(P), (pressure independent) valve kit on/off or VOT, three
way valve and actuator on/off
Included in SIReFC Competent:
•SIReUA1, control unit. Wall unit cover included.
•SIReC1X, PC board HUB Competent
•SIReCC, modular cables, RJ12(6p/6c), 3 m resp. 5 m
Options:
•SIReRTX, external room temperature sensor, RJ11 (4p/4c),
10 m
•SIReUR, kit for recessed installation
•VOS(P), (pressure independent) valve kit on/off or VOT, three
way valve and actuator on/off
Accessories - SIRe
Type
Description
SIReRTX
SIReUR
SIReWTA
SIReCJ4
SIReCJ6
SIReCC603
SIReCC605
SIReCC610
SIReCC615
SIReCC403
SIReCC405
SIReCC410
SIReCC415
External room temperature sensor
Kit for recessed installation
Clamp-on sensor
Joint piece for two pcs RJ11 (4/4)
Joint piece for two pcs RJ12 (6/6)
Modular cable RJ12 3 m
Modular cable RJ12 5 m
Modular cable RJ12 10 m
Modular cable RJ12 15 m
Modular cable RJ11 3 m
Modular cable RJ11 5 m
Modular cable RJ11 10 m
Modular cable RJ11 15 m
Fan heaters
SIRe Basic
Water control
Valve kit VOS(P), VOT, VMO(P) or VMT is used to control the
water flow. For more information see the "Controls" section.
Included in SIReFA Advanced:
•SIReUA1, control unit. Wall unit cover included.
•SIReA1X, PC board HUB Advanced
•SIReOTX, outdoor temperature sensor
•SIReCC, modular cables, RJ12(6p/6c), 3 m resp. 5 m
Options:
•SIReRTX, external room temperature sensor, RJ11 (4p/4c),
10 m
•SIReUR, kit for recessed installation
•SIReWTA, clamp-on sensor, RJ11 (4p/4c), 3 m
•VMO(P), (pressure independent) modulating valve kit or
VMT, three way valve and modulating actuator
Included in SIReFAWM Advanced with mixing cabinet:
•SIReUA1, control unit. Wall unit cover included.
•SIReA1X, PC board HUB Advanced
•SIReOTX, outdoor temperature sensor
•SIReWTA, clamp-on sensor, RJ11 (4p/4c), 3 m
•SMM24, damper motor
•SIReCC, modular cables, RJ12(6p/6c), 3 m resp. 5 m
Options:
•SIReRTX, external room temperature sensor, RJ11 (4p/4c),
10 m
•SIReUR, kit for recessed installation
•VMO(P), (pressure independent) modulating valve kit or
VMT, three way valve and modulating actuator
Water control - SWH
Type
Description
Valve kit on/off, low flow, DN15, Kvs 0,90
Valve kit on/off, DN15, Kvs 1,8
Valve kit on/off, DN20, Kvs 3,4
Valve kit on/off, DN25, Kvs 7,2
Pressure independent valve kit on/off, low flow, DN15
Pressure independent valve kit on/off, DN15
Pressure independent valve kit on/off, DN20
Pressure independent valve kit on/off, DN25
3-way control valve and actuator on/off, DN15, Kvs 1,7
3-way control valve and actuator on/off, DN20, Kvs 2,5
3-way control valve and actuator on/off, DN25, Kvs 4,5
Modulating valve kit, low flow, DN15, Kvs 0,40
Modulating valve kit, DN15, Kvs 1,0
Modulating valve kit, DN20, Kvs 2,0
Modulating valve kit, DN25, Kvs 4,0
Pressure independent and modulating valve kit, low flow,
DN15
VMOP15NF Pressure independent and modulating valve kit, DN15
VMOP20
Pressure independent and modulating valve kit, DN20
VMOP25
Pressure independent andmodulating valve kit, DN25
VMT15
3-way control valve and modulating actuator, DN15,
Kvs 1,7
VMT20
3-way control valve and modulating actuator, DN20,
Kvs 2,5
VMT25
3-way control valve and modulating actuator,DN25,
Kvs 4,5
VAT
Adjustement tool for valve kits
VOS15LF
VOS15NF
VOS20
VOS25
VOSP15LF
VOSP15NF
VOSP20
VOSP25
VOT15
VOT20
VOT25
VMO15LF
VMO15NF
VMO20
VMO25
VMOP15LF
55
Fan heaters - water heated
2
3
SWB, mounting brackets
When not using the filter section or mixing cabinet the main
unit is suspended from the wall or ceiling using brackets SWB
(fig 2). Brackets are extra and supplied as a pair.
6
4
SWFTN, basic filter
Used as an alternative to the filter section. Provides the heating
coil with basic protection. The filter is easily fitted into the SW
unit and can be cleaned from either the top or bottom. The
SWH unit has a re-usable filter (fig 3).
SWF, filter section
Fig. 4. Filters the outdoor air or/and return air from particles
that might reduce the performance and reliability of SWH.
The disposable deep-pleated bagfilter is a cassette of synthetic
material. Filterclass G85 (EU3). The filter section is equipped
with filter on delivery.
Note! If the filter section is not used in combination with the
mixing cabinet, a return air intake (SWD) is required.
SWEF, extra filtercassette
Replacement filter for SWF.
SWD, return air intake
Fig. 5. Allows air intake when filter section is used without
mixing cabinet SWBS. Return air intake is not required when
the mixing cabinet is used.
SWBS, mixing cabinet
Fig. 6. The mixing cabinet is used to combine ventilation with
heating by mixing outdoor air with return air. The mixture
ratio is controlled and infinitely variable with a damper, either
manually or with a damper motor.
SWY, outer wall grille
Fig. 7. For intake of fresh air into the mixing cabinet. Grille of
hot zinc-plated steel panels.
SWLR, extra air director
Fig. 8. To direct the air stream sideways. On delivery, SWH is
equipped with an air director for vertical direction of the air
stream. Individually adjustable louvres in anodised aluminium.
The extra air director is mounted to SWH by hooking it onto
the existing air director.
56
1
8
5
1) Fan heater SWH
2) Mounting brackets SWB
3) Basic filter SWFTN
4) Filter section SWF
5) Return air intake SWD
6) Mixing cabinet SWBS
7) Outer wall grille SWY
8) Extra air director SWLR
Accessories - Fan heater SWH and SWS
Type
Description
SWB0
SWB1
SWB2
SWB3
SWFTN02
SWFTN1
SWFTN2
SWFTN3
SWF1
SWF2
SWF3
SWEF1
SWEF2
SWEF3
SWD1
SWD2
SWD3
SWBS1
SWBS2
SWBS3
SWY1
SWY2
SWY3
SWLR1
SWLR2
SWLR3
Mounting brackets SWH/SWS02
Mounting brackets SWH/SWS12
Mounting brackets SWH/SWS22
Mounting brackets SWH/SWS32/33
Basic filter SWH/SWS12
Basic filter SWH/SWS12
Basic filter SWH/SWS22
Basic filter SWH/SWS32/33
Filter section SWH/SWS12
Filter section SWH/SWS22
Filter section SWH/SWS32/33
Extra filter cassette SWH/SWS12
Extra filter cassette SWH/SWS22
Extra filter cassette SWH/SWS32/33
Return air inlet (SWF1) SWH/SWS12
Return air inlet (SWF2) SWH/SWS22
Return air inlet (SWF3) SWH/SWS32/33
Mixing cabinet SWH/SWS12
Mixing cabinet SWH/SWS22
Mixing cabinet SWH/SWS32/33
Outer wall grille SWH/SWS12
Outer wall grille SWH/SWS22
Outer wall grille SWH/SWS32/33
Extra air director SWH/SWS12
Extra air director SWH/SWS22
Extra air director SWH/SWS32/33
7
Fan heaters - water heated
Fan heater SWS
3
2
Fan heater SWS is intended for water-heating or cooling. SWS
is suitable for places where fan heaters are traditionally used,
such as industrial premises, workshops and storage rooms.
The fan heater can be mounted on the wall or the ceiling. By
turning the unit the water connections will be positioned on
the left or right side.
Fan heater SWS has a compact and functional design well
suitable for the applications it is intended for.
7
6
4
Fan heater SWS (IPX4)  2
Voltage Output* Airflow Sound HxBxD
Weight
level
[V]
[kW]
[m³/h] [dB(A)] [mm]
[kg]
SWS02 230V~
12
1260
50
470x520x260 14
SWS12 230V~
19
2340
57
545x540x275 18
SWS22 230V~
30
3560
58
675x690x275 26
SWS32 230V~
50
6300
64
800x830x350 45
SWS33 230V~
65
6090
64
800x830x350 45
SWS323 400V3~ 48
5890
62
800x830x350 45
SWS333 400V3~ 62
5660
62
800x830x350 45
*) Applicable at water temperature 80/60 °C, surrounding temperature
+15 °C, fan position: max.
5
1
8
1) Fan heater SWS
2) Mounting brackets SWB
3) Basic filter SWFTN
4) Filter section SWF
Type
9
5) Return air intake SWD
6) Mixing cabinet SWBS
7) Outer wall grille SWY
8) Extra air director SWLR
9) Drip tray SWST
RE1,5/RE3/RE7, 5-step change-over switch for air flow
Controls the air flow in 5 steps. RE1,5 controls maximum 1,5
A. RE3 controls maximum 3 A. RE7 controls maximum 7 A. To
control the heat, a suitable thermostat and a valve + actuator
are needed. IP54.
STDT16, thermal contact motor protection
Switches off the supply voltage to the motor when the thermal
contact in the motor windings is tripped. The motor protector
is reset by pressing the black button as soon as the motor
windings have cooled sufficiently. IP55.
Control options 230V~
SWYD1, 2-step change-over switch for air flow (Y/D)
Control by thermostat only
Controls the air flow in two steps. One change-over switch for
each unit. IP66.
- KRT1900 or T10/TK10, room thermostat
- TVV20/25, valve + SD20, actuator
SWST, drip tray
5-step control of airflow only
Used to collect condensation when the unit is used for cooling.
- RE1,5, 5-step regulator max 1,5A, or
RE3, 5-step regulator max 3A, or
RE7, 5-step regulator max 7A
For information about other accessories, see fan heater SWH.
Thermostat and 5-step control
Accessories - Fan heater SWS
- RE1,5, 5-step regulator max 1,5A, or
RE3, 5-step regulator max 3A, or
RE7, 5-step regulator max 7A
- KRT1900 or T10/TK10, room thermostat
- TVV20/25, valve + SD20, actuator
Control options 400V~
2-step control of airflow only
- SWYD1, 2-step change-over switch for air flow (Y/D)
- STDT16, thermal contact motor protection
Heat controlled by thermostat and 2-step control of air flow
- SWYD1, 2-step change-over switch for air flow (Y/D)
- STDT16, thermal contact motor protection
- KRT1900 or T10/TK10, room thermostat
- TVV20/25, valve + SD20, actuator
Conditions for sound level measurements, see page 67.
Fan heaters
•Mounted on the wall or ceiling.
•Intended for water temperatures up to +125 °C and 10 bar in
standard design.
•Colour: grey. Louvres in anodised aluminium.
•CE compliant.
Type
Description
RE1,5
5-step change-over switch for airflow 1,5 A
RE3
5-step change-over switch for airflow 3 A
RE7
5-step change-over switch for airflow 7 A
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
KRT1900
Room thermostat, IP55
TVV20
2-way control valve DN20
TVV25
2-way control valve DN25
SD20
Actuator
STDT16
Thermal contact motor protection, IP55
SWYD1
2-step change-over switch for air flow (Y/D), IP66
SWST02
Drip tray SWS02
SWST1
Drip tray SWS12
SWST2
Drip tray SWS22
SWST3
Drip tray SWS32/33
For controls, see pages 63-64 and 66.
57
Fan heaters - water heated
Fan heater SWT
The SWT fan heater is used for heating entrances, stores,
industrial premises, workshops, sports halls, garages and shops.
The low height means that SWT can also be recessed into a
suspended ceiling.
The SWT fan heater has a robust design in white enamelled
steel panels. SWT is intended for water connection and is
ceiling mounted.
•Installed directly to the ceiling or suspended from brackets.
•Intended for water temperatures up to +80 °C and 10 bar.
•Two fan speeds.
•Colour: white.
•CE compliant.
Fan heater SWT (IPX4)
Type
2
1
3
1) Fan heater SWT
2) Filter SWTCF
3) Air director SWTCL
4) Extension collar SWTCE
4
Output* Airflow
Sound
HxWxD
Weight
level
[kW]
[m³/h]
[dB(A)]
[mm]
[kg]
SWT02
11
1100
53
330x705x535
19
SWT12
18
2000
57
355x825x675
26
SWT22
40
3900
60
415x1135x710
41
*) Applicable at water temperature 80/60 °C, air temperature, in +15 °C
SWTCF, filter
With the filter installed the interval for cleaning the water coil
is extended. The filter is delivered in two pieces.
SWTCL, air director
Control options
Control by thermostat only
- KRT1900 or T10/TK10, room thermostat
- TVV20/25, valve + SD20, actuator
2-step control of airflow only
- CB20, control box
To avoid draughts at low ceiling heights the air director can be
installed to direct air more to the side.
SWTCE, extension collar
At high installation the outlet collar for the SWT can be
extended. This increases the throw pattern of the air.
SWTCE02 increases the throw pattern to 4-7 m, SWTCE12
increases it to 5-8 m and SWTCE22 to 7-12 m.
Thermostat and 2-step control
- CB20, control box
- KRT1900 or T10/TK10, room thermostat
- TVV20/25, valve + SD20, actuator
t
5-step control of airflow only
- RE1,5, 5-step regulator max 1,5A, or
RE3, 5-step regulator max 3A, or
RE7, 5-step regulator max 7A
Thermostat and 5-step control
- RE1,5, 5-step regulator max 1,5A, or
RE3, 5-step regulator max 3A, or
RE7, 5-step regulator max 7A
- KRT1900 or T10/TK10, room thermostat
- TVV20/25, valve + SD20, actuator
CB20, control box
Controls the airflow in 2 steps. Can control several units. Max
input 12 A. IP44.
RE1,5/RE3/RE7, 5-step change-over switch for air flow
Controls the air flow in 5 steps. RE1,5 controls maximum
1,5 A. RE3 controls maximum 3 A. RE7 controls maximum
7 A. To control the heat, a suitable thermostat and a valve +
actuator are needed. IP54.
58
Accessories - Fan heaters SWT
Type
Description
CB20
Control box
RE1,5
5-step change-over switch for airflow 1,5 A
RE3
5-step change-over switch for airflow 3 A
RE7
5-step change-over switch for airflow 7 A
T10
Room thermostat, IP30
TK10
Room thermostat with knob, IP30
KRT1900
Room thermostat, IP55
RTI2
2-step room thermostat, IP44
RTI2V
2-step room thermostat with knob, IP44
TVV20
2-way control valve DN20
TVV25
2-way control valve DN25
SD20
Actuator
SWTCE02
Extension collar 350 mm SWT02
SWTCE12
Extension collar 350 mm SWT12
SWTCE22
Extension collar 350 mm SWT22
SWTCF02
Filter SWT02, 2 pcs
SWTCF12
Filter SWT12, 2 pcs
SWTCF22
Filter SWT22, 2 pcs
SWTCL02
Air director SWT02
SWTCL12
Air director SWT12
SWTCL22
Air director SWT22
For controls, see pages 63-64 and 66.
Conditions for sound level measurements, see page 67.
Industrial ceiling fan ICF
Industrial ceiling fan ICF
•The blades push down large volumes of air without causing
excessive air speed.
•Can operate clockwise and anti-clockwise.
•Canopy with vibration absorption.
•Fan blades and downrod coated with zinc.
•Colour: white, NCS S 0505-R90B.
•Protection class ICF20: IPX0.
•Protection class ICF55: IPX5.
•Approved by IMQ and CE compliant.
Control options
- CAR15, automatic fan speed control, for maximum15 fans,
reversible
- CFR1R, 5-step control for 1 fan, reversible
- RE5, 5-step control for a maximum of 12 fans
- PE1, variable fan speed control for a maximum of 2 fans
- PE2,5, variable fan speed control for a maximum of 6 fans
CAR15, automatic fan speed control
Automatic fan speed control, through
external sensor, in accordance with
variations in the temperature between the
ceiling and the floor. Built-in switch for
reversed rotation. Controls a maximum of
15 fans. IP33.
CAR15
Fan heaters
Ceiling fans are used primarily to equalize the temperature
in rooms with high ceilings, such as industrial and warehouse
buildings, gymnasiums, and shops. Several controls as well as
downrods and blades of different sizes are available, making it
possible to adapt ceiling fan ICF to almost all applications.
Ceiling fan ICF pushes the warm air from the ceiling and
thus lowers the temperature there, the heat losses through the
roof and walls are reduced and in many cases, heating costs
can be reduced by up to 30%.
Ceiling fan ICF is a high quality, maintenance free product
with long lifetime, which results in a very short pay-off time,
that is often less than one year.
Industrial ceiling fan ICF has a functional design and white
colour which blends well in most premises. The low sound
level makes it even more discreet.
CFR1R, 5-step control
5-step control. Built-in switch for reversed
rotation. Controls a maximum of 1 fan.
IPX0.
CFR1R
RE5, 5-step control
5-step control. Controls a maximum of 12
fans. IP54.
Ceiling fan ICF (ICF20:IPX0 / ICF55:IPX5)  3
Type
ICF20
ICF55
Voltage
[V]
230V~
230V~
Output
[W]
70
70
PE1/PE2,5, variable fan speed control
Airflow
[m³/h]
13500
13500
Height x Ø
[mm]
545x1422
545x1422
Weight
[kg]
6,2
6,2
Single-phase manual thyristor for variable
speed adjustment of the fan and on/off
regulation. External mounting (IP54) or
recessed mounting (IP44). PE1 controls
a maximum of 2 fans. PE2,5 controls a
maximum of 6 fans.
RE5
PE1/PE2,5
Accessories - ICF
a
a/2
a‘
Type
Description
CAR15
CFR1R
PE1
PE2,5
RE5
CFAP200
CFAP750
CFB900
CFB1200
Automatic fan speed control
5-step fan speed control for 1 fan
Stepless fan speed control for 2 fans
Stepless fan speed control for 6 fans
5-step fan speed control for 12 fans
Short downrod, total height 395 mm
Long downrod, total height 945 mm
Fan blades Ø 914 mm (3 pcs)
Fan blades Ø 1218 mm (3 pcs)
a‘/2
Ceiling height (m)
Distance between fans a (m)
Recommended distance between fans
4
6
8
10
12
5
7
8
9
10
59
Convectors
Convection is the term for the rotating air movement
where the air is affected by a heat source. The air is
heated - rises upwards - cools and comes back to
then be reheated. This gives good comfort through
good heat distribution and the warm air flow directed
upwards can be used to counteract cold drafts from
large glass surfaces.
Convectors and radiators are simple to install.
Our range contains a convector to suit all needs:
small, discreet, robust and hard-wearing or quick and
economical, all with the same high level of quality.
Bench heater SH
Mini radiator/frost guard
Bench heater SH is designed for use with church pews, waiting
room benches and the like. The bench heater is installed
under the seat and distributes heat in the occupied zone
through convection and radiant heat.
As heat is produced as soon as the heater is switched on, SH
is also an ideal and efficient option in slowly heated buildings
such as churches. Only heating the building when necessary
helps to keep down heating costs.
Bench heater SH has a discreet design especially adapted to
fit under benches and seats.
The mini radiator/frost guard gives off a lot of heat despite the
small size. The compact radiators are suitable for providing
frost protection, but can also be used to heat many different
areas, for example, homes, close to water pipes, small
warehouses, greenhouses and electrical cabinets.
The mini radiator/frost guard is available in white or
stainless steel designs and is very easy to position on account
of its small size.
•Approved for serial connection.
•Equipped with protecion grille and tube element of stainless
steel.
•Dual reflectors (external and internal) give downward heat
dispersion.
•Outer reflector is of zinc-plated steel panels and the heater is
grey lacquered. Colour: NCS 4000, RAL 7036 (grey).
•CE compliant.
•Mounted horizontally (FML/FMLR) or vertically (FMS) on the
wall.
•Stainless steel tubular element.
•Equipped with 1 metre long cord with plug for connection to
an earthed outlet socket.
•Integrated overheating protection.
•Integrated thermostat with setting range +5 – +35 °C.
•Colour front: NCS 1103-Y06R (white). FMLR200 has a
stainless steel design.
•CE compliant.
Bench heater (IP21)  3
Frostguard FMS, FML, FMLR (IP31)  3
Type
SH17521
SH17531
SH25021
SH25031
SH37521
SH37531
60
Voltage
[V]
230V~
400V2~
230V~
400V2~
230V~
400V2~
Heat output
[W]
175
175
250
250
375
375
LxHxD
[mm]
700x100x200
700x100x200
1000x100x200
1000x100x200
1500x100x200
1500x100x200
Weight
[kg]
1,4
1,4
1,9
1,9
2,9
2,9
Type
FMS200
FMLR200
FML200
FML300
FML450
Voltage
[V]
230V~
230V~
230V~
230V~
230V~
Heat output
[W]
200
200
200
300
450
LxHxD
[mm]
90x298x68
298x90x68
298x90x68
398x90x68
498x90x68
Weight
[kg]
0,7
0,7
0,7
0,9
1,1
Convectors
TWTC
TWT
Ribbed pipe radiator
Thermowarm TWT/TWTC
Frico's ribbed pipe radiators are designed for harsh
environments and are approved for wet rooms, but are also
available in designs for rooms at risk of fire. The retro design
has also created a new application area in modern housing.
Frico's ribbed pipe radiators have a hard wearing and robust
design in dark green sheet steel. The compact format means
the radiator has a small footprint, but gives a lot of heat.
Thermowarm is a series of easily installed convectors designed
for public buildings such as changing rooms, stores and
toilets. TWTC can also be used in corrosive and aggressive
environments. TWT200 has a surface temperature as low
as 60 °C, which makes it ideal for daycare centres and
bathrooms.
Thermowarm is easy to position and has, despite its small
size, a large heat output. The three different surface finishes:
white, grey covered panel covered and stainless steel, make
Thermowarm suitable for most environments. The front
cover can be opened making it straightforward to keep the
convectors clean and tidy.
•The ribbed pipe radiator is available in the following designs:
-Model 125, without output selector.
-Model 126, with output selector that regulates the heat in
three steps.
-Model 127, without output selector, sand-filled and
suitable for rooms at risk to fire.
•The ribbed flanges increase the heating surface and provide
good heat transfer combined with a compact design.
•Resettable overheating protection along the full length of the
ribbed pipe radiator.
•A protective steel case give a lower surface temperature and
extra protection against impact (model 125 and 126).
•Colour: dark green, RAL 6005, NCS 7020-B90G.
•CE compliant.
Type
125-12B
125-22B
125-32B
125-42B
126-32B
126-42B
126-52B
127-22B
127-42B
Voltage
[V]
230V~
230V~
230V~
230V~
230V~
230V~
230V~
230V~
230V~
Heat output
[W]
200
375
575
775
575
775
1150
500
800
TWT100 (IP44) white, with circuit breaker  3
LxHxD
[mm]
370x180x185
530x180x185
730x180x185
880x180x185
730x180x185
880x180x185
1185x180x185
980x180x185
1925x180x185
Weight
[kg]
2,4
3,3
4,5
5,5
4,7
5,7
7,5
10,9
33,3
Type
TWT10321
TWT10331
TWT10521
TWT10531
TWT11021
TWT11031
Voltage
[V]
230V~
400V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
300
500
500
1000
1000
LxHxD
[mm]
345x205x123
345x205x123
465x205x123
465x205x123
765x205x123
765x205x123
Weight
[kg]
1,5
1,5
2,0
2,0
3,0
3,0
TWT200 (IP44) covered front, with circuit breaker 60 °C  3
Type
TWT20321
TWT20331
TWT20521
TWT20531
TWT21021
TWT21031
Voltage
[V]
230V~
400V~
230V~
400V~
230V~
400V~
Heat output
[W]
300
300
500
500
1000
1000
LxHxD
[mm]
345x205x123
345x205x123
465x205x123
465x205x123
765x205x123
765x205x123
Weight
[kg]
1,5
1,5
2,0
2,0
3,0
3,0
Convec tors
Ribbed pipe radiator (IP44)  3
•With ribbed flanges and tubular elements.
•Integrated thermostat with setting range 0 – +35 °C.
•Resettable overheating protection along the full length of the
convector.
•Colour TWT100 and TWT300: white front, RAL 9016,
NCS S 0500-N, grey sides
Colour TWT200: grey covered front panel, grey sides
Colour TWTC: stainless steel design, black sides
•CE compliant.
TWT300 (IP21) white, with mains cord and plug   3
Type
TWT30321
TWT30521
TWT31021
Voltage
[V]
230V~
230V~
230V~
Heat output
[W]
300
500
1000
LxHxD
[mm]
345x205x123
465x205x123
765x205x123
Weight
[kg]
1,5
2,0
3,0
TWTC (IP54) stainless steel, with mains cord and plug  3
Type
TWTC30321
Voltage
[V]
230V~
Heat output
[W]
300
LxHxD
[mm]
345x205x123
Weight
[kg]
1,5
TWTC30521
230V~
500
465x205x123
2,0
TWTC31021
230V~
1000
765x205x123
3,0
61
Convectors
Fan convector PF
Fan convector PF is suitable for most environments, for
example, homes and offices. It is also ideal for use in buildings
that are rarely used, for example, weekend cottages, where
quick heating is required. The fan convector also has very
good drying properties. Models up to 800 W have a surface
temperature of less than 60 °C which makes them extremely
suitable for daycare centres and bathrooms.
The fan convector consumes less energy than standard
convectors. The air flow from the convector, which balances
the temperature difference between the floor and ceiling, gives
higher efficiency and lower energy consumption compared to
convectors without a fan.
Fan convector PF has an attractive and clean design in a
white finish. A brushed aluminium front is available as an
accessory. The low surface temperature makes it possible
to finish the front panel in any colour or a film finish can be
applied.
• Fan convector PF is available in the following designs:
- PFE is equipped with a 1.2 metre long cord with plug for
connection to an earthed outlet socket (230V~). Can be
used as a portable unit, a floor stand is available as an
accessory.
- PFD is designed for permanent installation (400V2~).
- PFW is for water based heating. Equipped with a 1.2
metre long cord with plug for connection to an earthed
outlet socket. Supplied with two, 0.9 m PEX hoses for easy
installation. Works with a heat pump.
• Low sound level.
• Master/slave function (PFE/PFD).
• Integrated thermostat with setting range 5 – +35 °C (PFE/
PFD).
•Prepared for night tariffs via external signal (PFE/PFD).
•Depth wall bracket PFE/PFD: 30 mm.
•Depth wall bracket PFW: 45 mm.
•Colour: white, RAL 9016, NCS S 0500-N (standard), brushed
aluminium as an accessory.
•CE compliant.
62
Fan convector PFE/PFD, electrically heated (IP23)  3
Type
PFE5
PFE8
PFE10
PFE12
PFD5
PFD8
PFD10
PFD12
Voltage
[V]
230V~
230V~
230V~
230V~
400V2~
400V2~
400V2~
400V2~
Heat output
[W]
500
800
1000
1200
500
800
1000
1200
LxHxD
[mm]
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
598x330x90
Weight
[kg]
6
6
6
6
6
6
6
6
Fan convector PFW, water heated (IP23)  2
Type
Voltage
Airflow Sound LxHxD
Heat
Weight
level*2
output*1
[kW]
[V]
[m3/h] [dB(A)] [mm]
[kg]
PFW10
230V~
1,1
59
42/32
598x330x90 7,3
PFW20
230V~
3,0
65
44/33
1058x330x90 13
*1) Applicable at water temperature 80/60 °C, air temperature, in +20 °C.
*2) Conditions: Distance to the unit: 3 metres. Directional factor: 2.
Equivalent absorption area: 200 m2.
Accessories - PFE/PFD/PFW
Type
Description
PFFAL
PFFS
Front, brushed aluminium
Floor stand PFE/PFD
Thermostats and controls
The control system is the intelligent centre and the
”brain” of a heating system and essential for good
comfort level and low energy consumption. The
temperature of an electric heating system can be
quickly, easily and precisely regulated and is more
responsive than any other heating system.
Frico offers a wide range of thermostats and controls,
read more under each product or in the Frico
catalogues.
TK10
TKS16(400)
TD10
RTI2
RTI2V
T, TK, TD, basic offer thermostats
RTI2, electronic 2-step thermostats
Processor controlled thermostats for room/floor heating.
Available with concealed/visible knob or digital display. Model
with visible knob also available with switch and in 400 V.
On/off control (for slow systems) or proportional control (for
faster systems) in the same thermostat. TD10 has adjustable
P-band and time of cycle.
Internal and/or external sensors (external sensor RTS01
available as an accessory) give the possibility of selecting the
sensor function e.g limiting external sensors (min/max). Save
reduction either by built-in manual switch or via external
timer. CE compliant.
Processor controlled 2-step thermostats for room heating /
cooling. Available with concealed or visible knob. Adjustable
temperature difference between the steps (1–10 degrees).
Save reduction via external connection timer (1–10 degrees).
External sensor (RTS01) available as an accessory.
High protection class (IP44). CE compliant.
Type
T10
TK10
TKS16
TKS16400
TD10
Voltage
[V]
230~
230~
230~
400V2~
230V~
Max input
[A]
10
10
16
16
10
Setting range
[°C]
5 - +30
5 - +30
5 - +30
5 - +30
5 - +37
HxWxD
[mm]
80x80x31
80x80x31
80x80x39
80x80x39
80x80x31
Type
RTI2
RTI2V
Voltage
[V]
230V~
230V~
Setting range
[°C]
5 - +35
5 - +35
HxWxD
[mm]
155x87x43
155x87x43
Accessories
Type
Description
RTS01
External floor/duct sensor
Ther mos t at s and c ontrols
T10
63
Thermostats and controls
KRT1900/1
KRTV19
TBK10
KRT2800
TBKS10
KRT, capillary tube thermostats
TBK, bimetal thermostats
Capillary tube thermostats for room heating/cooling. Available
with concealed and visible knob, and control in 1 or 2 steps.
KRT2800 controls in 2 steps and has adjustable temperature
difference between the steps (1–4 degrees). KRT1901 has a
temperature range of -35–+10 °C. High protection class (IP44
resp. IP55). CE compliant.
Mechanical bimetal thermostats with acceleration resistance
for room heating/cooling. TBKS10 also has a 1-pole switch.
CE compliant.
Type
KRT1900
KRT1901
KRTV19
KRT2800
Voltage
[V]
230/400V~
230/400V~
230/400V~
230/400V~
Setting range
[°C]
0 - +40
-35 - +10
0 - +40
0 - +40
Type
Voltage
[V]
230V~
230V~
TBK10
TBKS10
HxWxD
[mm]
165x57x60
165x57x60
165x57x60
165x57x60
Setting range
[°C]
5–30
5–30
CBT
HxWxD
[mm]
80x80x43
80x80x43
KUR
CBT, electronic timer
KUR, digital time switch
Electronic timer with alternating contact. Setting range 1/2-12-4 or 4-8-16-24 hours respectively. The setting range can be
limited down to a maximum time of 1/2 hours. IP44.
Digital weekly timer with 8 different program steps (36
memory places) equipped with a changeover contact. Max.
breaking current: 10 A. IP55.
Type
CBT
Voltage
[V]
230V~
HxWxD
[mm]
155x87x43
Type
Voltage
[V]
230V~
KUR
HxWxD
[mm]
175x85x105
Functions   |   Thermostats
Basic offer
T10
TK10
Electronic 2-step
TKS16
TD10
TKS16400
RTI2
KRTV19
KRT2800
TBK10
TBKS10
X
X
X
X
X
X
X
X
X
X
X
Internal sensor
X
X
X
X
X
X
X*¹
X*²
X*¹
X*²
X*¹
X*¹
X*¹
X*¹
X*²
X*²
X*²
X*²
X
X
X
X
X
1-pole switch
Volt free contact
X
X
Contact, 1-pole closing
X
X
X
X
X
Contact, 1-pole alternating
X
Internal setting
X
Processor controlled
X
X
X
X
X
X
X
Capillary tube
64
Adjustable temp.diff. between the
steps
*¹) External sensor (RTS01) as accessory.
*²) Can be used with an external timer.
*³) See manuals on www.frico.se.
X
X
X
X
X
X
X
X
Bimetallic
2-step
X
X
Advanced extra functions*³
Fits wall box system
X
X
Digital display
Heating or cooling function
Bimetallic
RTI2V
External sensor
Save reduction
Capillary tube
KRT1900
KRT1901
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Water control
VOS
VOSP
TBVC
SD230
AV
BPV10
VMO
TBVCMP
AV
SD230
TBVCM
SDM24
TBVCMP
SDM24
AV
ST23024
AV
ST23024
BPV10
VOT
VMOP
VMT
SD230
TRVS
SDM24
TRVS
ST23024
Complete valve kits with multifunctional terminal valves makes
new functions possible and ensures stable flows and exact control
using the modulating actuator. They are supplied at different levels
and have a low installation cost with few components. The valve
kit gives exact adjustment and means extra energy savings. Used to
control the water supply to water heated units with control system
SIRe.
Used with SIRe Basic and Competent
Used with SIRe Advanced
VOS, valve kit on/off
VMO, modulating valve kit
Two way combined control and adjustment valve with on/off
actuator, shut-off valve and bypass. DN15/20/25. 230V. Used
with SIRe Basic and Competent.
The valve kit consists of the following:
•TBVC, regulation and adjustment valve
•SD230, actuator on/off 230V
•AV, shut off valve
•BPV10, bypass valve
Two way combined control and adjustment valve with
modulating actuator and shut-off valve. DN15/20/25. 24V. Used
with SIRe Advanced.
The valve kit consists of the following:
•SDM24, modulating actuator 24V
•TBVCM, regulation and adjustment valve
•AV, shut off valve
•ST23024, 24V transformer for valve actuator (in valve kit with
24V)
VOSP, pressure independent valve kit on/off
VOT, three way control valve and actuator on/off
3-way control valve with on/off actuator, DN15/20/25. 230V.
The valve kit consists of the following:
•TRVS, 3-way control valve
•SD230, actuator on/off 230V
VMOP, pressure independent and modulating valve kit
Two way pressure independent control and adjustment valve
with modulating actuator and shut-off valve. DN15/20/25. 24V.
Used with SIRe Advanced.
The valve kit consists of the following:
•TBVCMP, pressure independent regulation and adjustment
valve
•SDM24, modulating actuator 24V
•AV, shut off valve
•ST23024, 24V transformer for valve actuator (in valve kit with
24V)
VMT, three way control valve and modulating actuator
3-way control valve with modulating actuator. DN15/20/25. 24V.
The valve kit consists of the following:
• TRVS, 3-way control valve
• SDM24, modulating actuator 24V
• ST23024, 24V transformer for valve actuator (in valve kit
with 24V)
Type
Flow
Connection
Kvs
Type
Flow
Connection
Kvs
VOS15LF
VOS15NF
VOS20
VOS25
VOSP15LF
VOSP15NF
VOSP20
VOSP25
VOT15
VOT20
VOT25
Low flow
Normal flow
Normal flow
Normal flow
Low flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
DN15
DN15
DN20
DN25
DN15
DN15
DN20
DN25
DN15
DN20
DN25
0,90
1,8
3,4
7,2
1,7
2,5
4,5
VMO15LF
VMO15NF
VMO20
VMO25
VMOP15LF
VMOP15NF
VMOP20
VMOP25
VMT15
VMT20
VMT25
Low flow
Normal flow
Normal flow
Normal flow
Low flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
Normal flow
DN15
DN15
DN20
DN25
DN15
DN15
DN20
DN25
DN15
DN20
DN25
0,40
1,0
2,0
4,0
1,7
2,5
4,5
Ther mos t at s and c ontrols
Two way pressure independent control and adjustment valve
with on/off actuator, shut-off valve and bypass. DN15/20/25.
230V. Used with SIRe Basic and Competent.
The valve kit consists of the following:
•TBVCMP, pressure independent regulation and adjustment
valve
•SD230, actuator on/off 230V
•AV, shut off valve
•BPV10, bypass valve
65
Water control
VR20/25
JVF20/25
TRV20/25
VR20/25
VR20/25
AV20/25
BPV10
AV20/25
AV20/25
JVF20/25
BPV10
JVF20/25
BPV10
TRV20/25
SD20
TRV20/25
SD20
T10/KRT
SD20
TVV20/25
T10/KRT
°C
230V ~
SD20
°C
230V ~
TVV20/25
SD20
SD20
T10/KRT
T10/KRT
°C
230V ~
VR 20/25, valve kit
For control of water flow to water heated air curtains.
The valve kit consists of the following:
• AV20/25, stop valve
• JVF20/25, adjustment valve
• TRV20/25, on/off 3-way control valve
• BPV10, by-pass valve
• SD20, actuator on/off 230V~
The stop valve (AV20/25) consists of a ball valve which is
either open or closed. It is used to turn the water flow off
and on. The water flow can be fine-tuned manually with the
adjustment valve and can also be completely turned off. The
water flow may be read off the valve. The kv value for JVF20 is
3,5 and for JVF25 it is 5,5.
If the 3-way valve (TRV20/25) is closed, the flow through the
by-pass valve (BPV10) is low to ensure presence of warm water
in the heating coil. This leads to instant heat supply when
needed and some degree of frost protection. The actuator
(SD20) works on/off.
The valve kit is available with two different valve
dimensions: VR 20 - DN20 (3/4”) and VR 25 - DN25 (1”). The
by-pass valve dimension is DN10 (3/8”). To regulate VR20/25,
a suitable thermostat has to be added.
TVV20/25
°C
230V ~
TVV20/25, valves + SD20, actuator
TVV20/25, 2-way regulation valve and SD20, actuator on/
off provides a basic form of water regulation, without the
possibility of adjusting or shutting the water flow off, e.g.
when making maintenance. A suitable thermostat is chosen to
regulate TVV20/25 and SD20. DN20/25.
TVV20/25, 2-way control valve
TVV20 has a pipe dimension of DN20 (3/4”) and TVV25 of
DN25 (1”). Pressure class PN16.
Maximum pressure 2 MPa (20 bar).
Maximum pressure drop TVV20: 100 kPa (1 bar)
Maximum pressure drop TVV25: 62 kPa (0,62 bar)
The kv-value is adjustable in 3 steps:
TVV20: kv 1,6, kv 2,5 and kv 3,5
TVV25: kv 2,5, kv 4,0 and kv 5,5
TRV20/25, 3-way control valve
If a 3-way valve is preferred, TRV20/25 can be used instead of
TVV20/25.
SD20, actuator on/off 230V~
SD20 regulates the heat supply. Works on/off. A 5 second
closing of the valve prevents sudden pressure changes in the
pipe system.
TE3434
Flexible hose, length 0,8 metres, for water heated units (2 is
needed for a unit) with external thread 3/4” (DN20) at one end
and coupling nut internal thread 3/4” (DN20), on the other.
These products can not be used together with control system SIRe.
66
Technical data
Symbols for model types
= normal design (no symbols), IPX0
= drip-proof design, IPX1
= splash-proof design, IPX4
= jet-proof design, IPX5
Protection classes for electrical material
Heat insulation, U-value
U = thermal transmittance value [W/m²°C]
U-values indicate the heat insulating capacity of a building
section.
Material
U-value
[W/m² °C]
IP, first figure
Protection against solid objects
0
No protection
Walls
1
Protection against solid objects ≥50 mm
New building
2
Protection against solid objects ≥12,5 mm
Wooden fascia with 15 cm insulation and plaster
0,27
3
Protection against solid objects ≥2,5 mm
Wooden fascia with 20 cm insulation and plaster
0,25
4
Protection against solid objects ≥1,0 mm
Wooden fascia with 25 cm insulation and plaster
0,22
5
Protection against dust
Brick fascia with 15 cm insulation and plaster
0,27
6
Dust-tight
Brick fascia with 20 cm insulation and plaster
0,24
Light concrete with 15 cm insulation
0,25
IP, second figure
Protection against water
Light concrete with 20 cm insulation
0,2
0
No protection
Sheet metal fascia with 5 cm insulation
0,8
1
Protection against vertically dripping water
Sheet metal fascia with 10 cm insulation
0,4
2
Protection against dripping water angled at max 15°
Sheet metal fascia with 15 cm insulation
0,3
3
Protection against sprinkled water
New construction for low energy house
0,18
4
Protection against spraying with water
Warehouse
0,3
5
Protection against water jets
One layer PVC (900 g)
5,0
6
Protection against heavy seas
Insulated hall (Thermohall)
0,6
7
Protection against short-term immersion in water
Older building
8
Protection against the effects of long-term
immersion in water
Single brick 12 cm
1,8
1 1/2 brick 18 cm
1,1
Light concrete block 20 cm
0,8
Light concrete block 30 cm
0,6
Concrete 15 cm
2,8
Concrete with 5 cm insulation
0,8
Concrete with 10 cm insulation
0,4
Frame wall with 5 cm insulation
0,8
Frame wall with 10 cm insulation
0,4
Frame wall with 15 cm insulation
0,3
New construction
0,3
How is sound measured?
Sound level is measured in decibels (dB). The dB is a
logarithmic unit used to describe a ratio. If the sound level is
increased by 10 dB, the result is twice as loud (as perceived by
human ear).
It is also useful to know that two equally strong sound
sources give an added sound level of 3 dB. Assume you have
two entrances with two air curtains in each entrance, all four
units with a sound level of 50 dB. The total sound level will
then be 56 dB. The first opening will have a total sound level of
53 dB plus an extra 3 dB from the other opening.
Roof
New building
Sheet metal pitched roof, with 20 cm insulation
0,24
Brick pitched roof, with 20 cm insulation
0,23
Older building
Points of reference – dB
Concrete beam frame 15 cm
2,8
0 The softest sound a person can hear
Concrete beam frame with 5 cm insulation
0,8
10 Normal breathing
Concrete beam frame with 10 cm insulation
0,4
30
Recommended max. level for bedrooms
Light concrete 20 cm
0,8
40 Quiet office, library
Light concrete 30 cm
0,6
50 Large office
Sheet metal roof, uninsulated
4,0
Sheet metal roof with 5 cm insulation
0,8
60 Normal conversation
Sheet metal roof with 10 cm insulation
0,6
80 Ringing telephone
Sheet metal roof with 25 cm insulation
0,2
85 Noisy restaurant
Windows
110 Shouting in ear
120 The threshold of pain
The sound level is stated for most of our product in the mini
catalogue. Our sound measurements are done according to
international standards BS 848, AMCA standard 210-85 and
DIN 24 163, (the distance to the product* 5 metres, directional
factor 2, equivalent absorption area 200 m²).
*) For fan heaters Tiger, Cat and Panther as well as convector
PF, the distance to the product is 3 metres.
New building
1+1 pane window (1 outer pane and 1 insulated pane)
2,5
2 pane window (2 insulated panes)
2,7
2+1 pane window (1 outer pane and 2 insulated panes)
1,0
3 pane window (3 insulated panes)
1,2
Energy class A
0,9
Energy class B
1,0
Energy class C
1,1
Energy class D
1,2
Energy class E
1,3
Energy class F
1,4
Energy class G
1,5
Older building
1 pane window
5,0
2 pane window
3,0
3 pane window
2,0
3 pane window insulation pane
1,8
67
Frico AB
Box 102, SE-433 22 Partille
Sweden
T
+ 46 31 336 86 00
F
+ 46 31 26 28 60
[email protected] • www.frico.se
Was this manual useful for you? yes no
Thank you for your participation!

* Your assessment is very important for improving the work of artificial intelligence, which forms the content of this project

Download PDF

advertisement